ST LUMIERE
Transcription
ST LUMIERE
ST LUMIERE Implementation guide Published on August 21st, 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 [email protected] www.pma.fr 2 SYSTEM DESCRIPTION The ST Lumiere decorative facing is a perforated panel made of stainless or pre-coated galvanized steed with a nominal thickness of 1 mm or in aluminum alloy with a thickness of 1.5 mm. These panels fit together by their longitudinal edges. This facing panel can be used as roofing cover, sunbreaker, interior decoration or aesthetic façade facing. This product can be used on new or renovated public or private buildings used for commercial or lodging purposes. (technical drawings – fig. 9 to 13) ST Lumiere facting does not participate in the general stability of the building (no wind bracing or anti-buckling functions). The support wall must provide the strength functions and stability of the façade and meet requirements in the matter of air and water permeability. A special version can be used for installing grating. (finish in C) (technical drawings – fig. 3 to 8) TECHNICAL CHARACTERISTICS Planview of perforation • • • • • Manufacture by bending. (technical drawings – fig. 1 & 2) Useful width: 300 mm 1 mm. Nominal height: 30 mm +0mm/-1 mm conventional finish 30 to 60 mm +0mm/-1 mm finish in C. Perforation module: de 61.15 mm to 61.4 mm Length 1000 mm – about 6000 mm maximum +1mm / - 2 mm multiple of perforation pitch. 3 MATERIALS Thick.(mm) 1 Steel Grade S320GD + Z 225 Standard NF EN 10326 P 34310 Stainless Steel 1 1.4301 1.4404 NF EN 10088-2 Aluminium Alloy 1 to 1.2 3003 NF A 50-451 Coating Standard Pre-coated as ARVAL Colorissime chart XP P34301 Post-coated by polyester powdering P 24351 Pre-coated Post-coated by polyester NF P 34-601 PMA should be consulted concerning the feasibility of various colors and surface appearances: • • • • Pre-coated and pearly steel: Colorissime or Novolac color chart. Steel post-coated by dusting: RAL color chart. Pre-coated aluminum alloy: Alcan color chart. Post-coated aluminum alloy: RAL color chart. FINISHING ELEMENTS These are manufactured from the same plates (same thickness, same material quality) as the panels, in maximum lengths of 6 m. • • • • Acroterion crown (technical drawings – fig. 14 & 18) Flaps (technical drawings – fig. 15 & 20) Outside and inside corners (technical drawings – fig. 16 & 22 to 24) Various connections. (technical drawings – fig. 19) COMPONENTS AND PARTICULAR FEATURES ST Lumiere panels are designed to be installed on a ruled secondary frame. This frame serves as bearing and attachment support for the ST Lumiere panels. This secondary frame is a construction element by itself and is not an integral part of the ST Lumiere process. Nevertheless, proper execution is a condition for the final result, notably as concerns the appearance of the facing. The separation of frames is to be determined by the loads applied to the panels. The table of allowable loads in normal wind as a function of the spans given in the appendix determines this separation for ST Lumiere panels in 10/10ths steel (consult us for other materials and thicknesses). No frame alignment or flatness errors can be compensated by the ST Lumiere panels themselves. The allowable loads and spans of the ST Lumiere panels under normal climatic conditions have been determined by tests considering the following criteria: • • Deflections of at most 1/200th of the span Safety coefficient with respect to ruin greater than 2 for panels from steel sheet. For aesthetic considerations, it is also advised to limit the spans to 1.5 m. 4 ST Lumiere panels are installed and attached on metal rails with the following characteristics: • • Bearing width of at least 40 mm. The thickness of the secondary frame sections must notably allow construction of assemblies with a minimum characteristic strength of 300 daN. Normal allowable wind loads on ST Lumiere panels in 10/10ths steel, in daN/m², Pressure & Vacuum Installation of panels by male-female fit Simple span – 2 supports Pressure/Vacuum Span (m) 120 120 113 101 90 81 74 67 61 57 49 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 Continuity – 3 or more supports Pressure/Vacuum 120 120 120 120 120 100 96 93 90 86 83 Weight: 11.1 kg/m² For the installation of grating type panels, consult P.M.A. for the allowable loads. ATTACHMENTS ST Lumiere panels in C are installed with special brackets secured to the frame by self-drilling screws. As these brackets are attached through the panel by passing the tool through a perforation opening, the carrier frame separation thus has to be a multiple of the peroration step. Frame aligned on perforation opening 5 ORGANIZATION The PMA company is the product manufacturer and does not install the product. The panels are to be installed by contractors having the required professional qualifications. Design and studies prior to executing the facade are not incumbent on the maker PMA nor on the distributor companies. On request, PMA can provide technical assistance. The purpose of the present specification is not to give details on all points of implementation but to state the main technical definitions of the panels and their particular characteristics. To help in the study of the facades, it is complemented in the appendix with particular design suggestions and finishing elements. HANDLING AND CONDITIONING A delivery invoice is glued to each package stating: • • • • • • • Customer order reference, Batch reference, Customer name Type of product Facing thickness Bundle content (number and length) Color reference of pre-coated steels. ST Lumiere panels are packed on the production line. The weight of the bundles may in no case exceed 2.5 tons. ST Lumiere panels and their accessories are to be transported under conditions that preserve the integrity of the characteristics (shimmed up packages, carefully stacked and strapped, tarpaulin-covered trucks). Handling operations are carried out in consideration of the particular features of the products. They are to be handled vertically on edge. TRANSPORT, STORAGE AND MAINTENANCE The panels are stored in bundles, slightly inclined in the longitudinal direction on a flat surface, without stacking more than two packages. Storage time on the work site is to be reduced to the minimum. The essential precaution consists in avoiding water from entering by runoff or condensation between the panels. Store sheltered from sunlight. The peel-off protective film covering the pre-coated panels is to be removed as work advances, at the latest 15 days after shipment. Custom manufacture makes it possible to limit the cutting on the work site. As required, cutting operations on site are performed using the appropriate equipment (jigsaw, nibbler, fine-tooth saw). It is strictly prohibited to use a grinder wheel. Watch out to avoid hot particles from being incrusted on the coating. All dirt (filings, drilling chips, etc.) are to be eliminated immediately. Metallic facades have to be normally maintained in accordance with the prescriptions of the Professional Rules for Metallic Siding (article 4-2-91 exterior maintenance). Although naturally cleanable by runoff of rainwater, if needed, they can be cleaned periodically with household detergent, without chlorine added, with no use of abrasive or solvent, followed by rinsing with fresh water. 6 Maintenance notably consists of: • • Eliminating various vegetation (such as moss) and any incompatible matter that might be deposited on the facing surface. Repair of any localized degradation as soon as detected, such as incipient corrosion caused, for example, by exterior deterioration actions. DRAWINGS OF DETAILS OF PRINCIPLE The following drawings are examples of how singular point of ST Lumiere panels are treated on a facade. Any other solutions can be considered and studied by the installing contractor in consideration of the specific characteristics of the product. 7 For any further information, please consult us. IMPORTANT The content of this document is based on data relative to construction and to materials properties. It is designed to assist PMA customers in implementing its products. Based on the construction processes and methods known at the time of its publication, this Implementation Guide cannot be considered final and may be revised and/or modified at any time. 8 TECHNICAL DRAWINGS ST Lumiere - « C » finishfinish ST Lumiere - « C » Ma x le ng th 60 00 m Ma x le ng th 60 00 m m m Length multiple pitchofofperforing perforing Length asofpitch ST Lumiere – Classic finish fig.1 ST Lumiere – Classic finish Vertical section fig.2 9 ST Lumiere – « C » finish Vertical section fig.3 Attachment ST Lumiere – Classic finish Vertical section fig.4 Attachment ST Lumiere – « C » finish Vertical section fig.5 10 ST Lumiere – Duck-boards installation fig.6 ST Lumiere – Duck-boards installation Vertical section ST Lumiere panel - « C » finish Subframe Self-drilling screw Attach leg fig.7 ST Lumiere – Attachment system for duck-boards installation Attach leg Self-drilling screw fig.8 11 ST Lumiere installed as sun-breaker fig.9 ST Lumiere installed as sun-breaker fig.10 12 Attachment system for ST Lumiere installed as sun-breaker Frame Self-drilling screw fig.11 ST Lumiere for facades fig.12 13 ST Lumiere for facades fig.13 Acroterion Attach leg Acroterion crown ST lumiere panel fig.14 Flap Standard lower flap fig.15 14 Re-entrant right corner ST Lumiere - Vertical installation fig.16 Angle piece – horizontal section Connecting plate Subframe Length max. 6000 mm Folded angle piece ST Lumiere panel fig.17 fig.18 15 ST Lumiere for facades – Horizontal installation ( from the top to the bottom) fig.19 Acroterion Crown ST Lumiere panel Attach leg fig.20 Flap ST Lumiere panel Perforated lower flap fig.21 16 ST Lumiere - Horizontal installation ( from the top to the bottom) – Right angle fig.22 Connecting plate Folded piece Length max. 6000 mm X and Y as request fig.23 fig.24