CVTR - tecno-ventil air governance
Transcription
CVTR - tecno-ventil air governance
blades coupled by means of belts and pulleys CVTR - Enclosed fans with dual inlet with reverse curved 5-2.0-03.00-E-03/07 components for air-conditioning systems CVTR Enclosed fans CVTR Enclosed fans with dual inlet with reverse curved blades coupled by means of belts and pulleys Accessories - PCV (mounting feet) - AV (anti-vibration joint) - PALT (aluminium panels) - PADT (double panel) - TCVT (rain-proof cover) - SPC (overpressure relief damper) - STA, STZ (regulating damper) - TR (expulsion duct) - M-1B (safety cut-off switch) - RV... (inverter) The CVTR series fans are particularly recommended for use in systems that are required to change the air. Their particular characteristic is their quietness, which makes then ideal in public rooms (dwellings, bars, restaurants, gymnasia and offices) as well as industrial locations. Their low level of noise emission is due to the casing being covered with phonoabsorbent material that enables a significant reduction in the level of the noise inevitably produced by the fan. The range includes various square inlet models in sizes from 180 to 450. The flow rates range from 1000 m3/h to 15000 m3/h and with static pressures up to 3000 Pa. The fan has a dual inlet centrifuge, reverse curved blades, and is coupled to the motor by means of trapezoidal belts and pulleys. The fan and the motor are mounted on anti-vibrating supports. Maximum operating temperature is 40°C. Quick reference selection table CVTR 180 200 250 315 400 450 400 Pa 600 Pa 800 Pa 1000 Pa 1500 Pa 2000 Pa m /h kW rpm dB kW rpm dB kW rpm dB kW rpm dB kW rpm dB 1000 0,55 3333 75 0,55 3.875 78 0,55 4.353 80 0,55 4.785 84 1,1 5.731 89 2000 0,55 4598 86 0,75 5002 88 1,1 5.376 89 1,1 5.725 89 2000 0,55 3519 81 0,75 3.926 81 1,1 4.293 83 1,1 4.632 85 1,5 5.388 89 3000 1,1 4481 88 1,5 4821 91 1,5 5.131 92 2,2 5.421 92 3000 0,75 2669 83 1,1 3.004 82 1,1 3.308 84 1,5 3.589 86 2,2 4.220 90 3 4.779 95 4 5.287 98 4000 1,1 3116 88 1,5 3408 88 2,2 3.675 89 2,2 3.926 88 3 4.495 91 4 5.007 93 5,5 5.478 96 4000 0,75 1910 78 1,1 2.183 80 1,5 2.429 83 2,2 2.655 87 3 3.161 92 4 3.608 96 6000 1,5 2330 87 2,2 2558 89 3 2.766 90 3 2.960 89 4 3.401 92 6000 1,1 1458 78 1,5 1.682 82 2,2 1.883 85 3 2.068 86 5,5 2.482 92 10000 3 1860 90 3 2036 91 4 2.198 89 5,5 2.350 90 7,5 2.696 93 10000 2,2 1455 86 3 1.628 86 4 1.787 87 5,5 1.934 89 7,5 2.267 93 15000 4 1855 83 5,5 1993 94 7,5 2.122 94 7,5 2.244 95 w w w. t e c n o v e n t i l . c o m kW 2500 Pa 3 rpm dB kW rpm dB VER. 30/08/10 We reserve the right to make any modifications without prior notice. 1 CVTR Enclosed fans Dimensions Pr i n c i p a l d i m e n s i o n s Dimension table CVTR Dimension (mm) C D A B E Kg 180 700 500 500 229 229 40 200 800 600 600 256 256 50 250 800 600 600 322 322 68 315 1000 700 700 404 404 100 400 1100 900 900 507 507 145 450 1200 1100 1100 569 569 200 Construction Aluminium profile frame with removable panels in zinc plated sheet with phonoabsorbant material, that gives the machine an excellent impact, both visual and functional, electric fan in zinc plated sheet. 2 VER. 30/08/10 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m Enclosed fans CVTR Technical data Wo r k i n g c u r v e s C V T R 1 8 0 Data Max rpm Maximum power Moment of inertia No. blades Impeller diameter Legend Δpstat RPM V pdin c LW P W 7000 1/min 3 kW 0,005 kgm2 8 180 mm [Pa] [1/min] [m3/h] [Pa] [m/s] [dB(A)] [%] static prevalence No. revolutions air flow rate dynamic pressure effective jet velocity Sound power performance pstat [Pa] 2400 RPM 7000 2300 55% 62% 6900 2200 6800 66% 6700 2100 6600 2000 6500 6400 1900 102 6300 6200 1800 6100 68% 6000 1700 5900 1600 100 dB 5800 5700 1500 64% 5600 5500 5400 5300 5200 5100 5000 4900 4800 4700 4600 4500 4400 4300 4200 4100 1400 1300 1200 1100 1000 900 800 98 59% 96 50% 94 92 3900 700 3700 600 1,5 39% 90 3500 88 3300 500 3100 400 2900 2700 2500 300 2234 200 86 84 kW 82 80 78 1,1 0,18 100 0 68% 0 400 0 0 800 1200 10 1600 0,37 0,25 2000 2400 50 5 0,55 2800 100 10 0,75 3200 3600 200 15 23% V [m³/h] pdin. [Pa] c [m/s] N.B.The diagrams relate to air with a density of 1,2 kg/m , open extraction and ducted supply. The level of sound power LW is A-weighted within the supply duct and at the suction inlet. 3 w w w. t e c n o v e n t i l . c o m VER. 30/08/10 We reserve the right to make any modifications without prior notice. 3 CVTR Enclosed fans Wo r k i n g c u r v e s C V T R 2 0 0 Data Max rpm Maximum power Moment of inertia No. blades Impeller diameter 6200 2,5 0,01 8 200 2400 1/min kW kgm2 mm 6000 2100 5900 65% 5800 2000 68% 5700 5600 1900 5500 1800 104 5400 68% 5300 1700 5200 1600 5100 5000 1500 64% 102 dB 4900 1400 4800 4700 1300 4600 58% 100 4500 1200 4400 4300 4200 4100 4000 3900 3800 3700 3600 3500 3400 3300 3200 3100 1100 1000 900 800 700 600 98 94 2500 2300 300 2053 200 37% 92 90 2700 400 48% 96 2900 500 88 kW 86 1,1 0,18 0 0 0 400 24% 1,5 84 82 100 0 static prevalence No. revolutions air flow rate dynamic pressure effective jet velocity Sound power performance 59% 6100 2200 [Pa] [1/min] [m3/h] [Pa] [m/s] [dB(A)] [%] 51% RPM 6200 2300 Legend Δpstat RPM V pdin c LW P W 800 1200 10 1600 0,25 2000 2400 2800 50 5 0,75 0,55 0,37 3200 3600 100 10 4000 4400 200 15 pdin. [Pa] c [m/s] N.B.The diagrams relate to air with a density of 1,2 kg/m3, open extraction and ducted supply. The level of sound power LW is A-weighted within the supply duct and at the suction inlet. 4 VER. 30/08/10 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m Enclosed fans CVTR Wo r k i n g c u r v e s C V T R 2 5 0 Data Max rpm Maximum power Moment of inertia No. blades Impeller diameter 5800 5 0,02 8 250 Legend Δpstat RPM V pdin c LW P W 1/min kW kgm2 mm [Pa] [1/min] [m3/h] [Pa] [m/s] [dB(A)] [%] static prevalence No. revolutions air flow rate dynamic pressure effective jet velocity Sound power performance pstat [Pa] 3100 RPM 5800 3000 5700 2900 5600 2800 5500 2700 5400 2600 5300 2500 5200 2400 5100 64% 68% 108 106 dB 4900 2200 71% 70% 5000 2300 67% 4800 2100 4700 2000 4600 1900 104 4500 1800 61% 4400 4300 1700 4200 1600 102 4100 1500 4000 52% 3900 1400 3800 1300 100 3700 3600 3500 3400 3300 3200 3100 3000 2900 2800 1200 1100 1000 900 800 700 5,5 98 39% 96 94 2600 600 92 2400 500 1800 1604 200 kW 88 2000 300 24% 90 2200 400 2,2 82 0,18 0 0 500 4 3 86 100 0 59% 0,37 0,55 0,75 1,5 1,1 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 10 0 50 5 100 10 200 15 300 20 V [m³/h] pdin. [Pa] c [m/s] 25 N.B.The diagrams relate to air with a density of 1,2 kg/m3, open extraction and ducted supply. The level of sound power LW is A-weighted within the supply duct and at the suction inlet. w w w. t e c n o v e n t i l . c o m VER. 30/08/10 We reserve the right to make any modifications without prior notice. 5 CVTR Enclosed fans Wo r k i n g c u r v e s C V T R 3 1 5 Data Max rpm Maximum power Moment of inertia No. blades Impeller diameter 3700 5,60 0,05 8 315 Legend Δpstat RPM V pdin c LW P W 1/min kW kgm2 mm [Pa] [1/min] [m3/h] [Pa] [m/s] [dB(A)] [%] static prevalence No. revolutions air flow rate dynamic pressure effective jet velocity Sound power performance pstat [Pa] 2200 RPM 3700 59% 67% 2100 72% 3600 2000 3500 1900 74% 3400 1800 104 3300 1700 74% 3200 1600 3100 1500 71% 102 3000 1400 2900 1300 65% 2800 1200 100 dB 2700 1100 2600 1000 98 2500 2300 800 96 2200 700 2100 94 46% 2000 600 4 92 1900 1800 500 90 1700 1600 400 1500 1400 300 1213 200 kW 88 33% 3 86 84 82 2,2 100 0 57% 2400 900 0,37 0,18 0 0 0 1000 2000 3000 10 4000 0,55 5000 6000 50 5 1,1 0,75 7000 8000 1,5 9000 100 10 10000 V [m³/h] 200 15 pdin. [Pa] c [m/s] N.B.The diagrams relate to air with a density of 1,2 kg/m3, open extraction and ducted supply. The level of sound power LW is A-weighted within the supply duct and at the suction inlet. 6 VER. 30/08/10 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m Enclosed fans CVTR Wo r k i n g c u r v e s C V T R 4 0 0 Data Max rpm Maximum power Moment of inertia No. blades Impeller diameter 2850 7,50 0,15 8 400 Legend Δpstat RPM V pdin c LW P W 1/min kW kgm2 mm [Pa] [1/min] [m3/h] [Pa] [m/s] [dB(A)] [%] static prevalence No. revolutions air flow rate dynamic pressure effective jet velocity Sound power performance pstat [Pa] 2100 RPM 2850 2000 62% 69% 74% 2800 1900 77% 2700 1800 104 dB 1700 2600 77% 1600 2500 1500 1400 2300 1300 1100 69% 100 2200 1200 2100 1000 98 2000 900 60% 1900 96 1800 800 1700 700 94 47% 1600 600 92 1500 500 1400 90 1300 400 88 1200 1100 300 955 200 kW 86 0,25 0,37 0 30% 5,5 4 84 82 100 0 75% 102 2400 0,55 0,75 1,1 1,5 3 2,2 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 V [m³/h] 0 0 10 50 5 100 10 200 15 pdin. [Pa] c [m/s] 20 N.B.The diagrams relate to air with a density of 1,2 kg/m3, open extraction and ducted supply. The level of sound power LW is A-weighted within the supply duct and at the suction inlet. w w w. t e c n o v e n t i l . c o m VER. 30/08/10 We reserve the right to make any modifications without prior notice. 7 CVTR Enclosed fans Wo r k i n g c u r v e s C V T R 4 5 0 Data Max rpm Maximum power Moment of inertia No. blades Impeller diameter 2500 8 0,33 8 450 Legend Δpstat RPM V pdin c LW P W 1/min kW kgm2 mm [Pa] [1/min] [m3/h] [Pa] [m/s] [dB(A)] [%] static prevalence No. revolutions air flow rate dynamic pressure effective jet velocity Sound power performance 2100 RPM 2500 2000 59% 69% 75% 1900 2400 77% 1800 104 1700 2300 77% 1600 2200 1500 102 75% 2100 1400 1300 2000 69% 100 dB 1200 1900 1100 1800 98 1000 61% 1700 900 96 1600 800 1500 700 94 49% 1400 600 7,5 92 1300 500 90 1200 400 88 1100 1000 300 850 200 kW 86 84 4 82 100 0 1,1 0,37 0,55 0 0 0 2000 32% 5,5 4000 6000 10 8000 10000 12000 1,5 14000 50 5 2,2 16000 3 18000 100 10 20000 22000 200 15 pdin. [Pa] c [m/s] 20 N.B.The diagrams relate to air with a density of 1,2 kg/m3, open extraction and ducted supply. The level of sound power LW is A-weighted within the supply duct and at the suction inlet. 8 VER. 30/08/10 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m CVTR Enclosed fans Te c h n i c a l d a t a CVTR Motor power rating (kW) IP Protection class Voltage (V) Maximum current (A) Weight (kg) 180 0,55 55/F 220/380 2,60 / 1,50 35 180 0,75 55/F 220/380 3,30 / 1,90 37 180 1,1 55/F 220/380 4,52 / 2,60 38 200 0,55 55/F 220/380 2,60 / 1,50 47 200 0,75 55/F 220/380 3,30 / 1,90 48 200 1,1 55/F 220/380 4,52 / 2,60 50 200 1,5 55/F 220/380 6,10 / 3,50 56 200 2,2 55/F 220/380 8,40 / 4,80 47 250 0,75 55/F 220/380 3,30 / 1,90 51 250 1,1 55/F 220/380 4,52 / 2,60 53 250 1,5 55/F 220/380 6,10 / 3,50 59 250 2,2 55/F 220/380 8,40 / 4,80 61 250 3 55/F 220/380 11,5 / 6,60 53 250 4 55/F 220/380 14,5 / 8,30 59 250 5,5 55/F 220/380 19,2 / 11,00 61 315 0,75 55/F 220/380 3,30 / 1,90 95 315 1,1 55/F 220/380 4,52 / 2,60 83 315 1,5 55/F 220/380 6,10 / 3,50 86 315 2,2 55/F 220/380 8,40 / 4,80 95 315 3 55/F 220/380 11,5 / 6,60 97 315 4 55/F 220/380 14,5 / 8,30 105 400 1,1 55/F 220/380 4,52 / 2,60 132 400 1,5 55/F 220/380 6,10 / 3,50 142 400 2,2 55/F 220/380 8,40 / 4,80 143 400 3 55/F 220/380 11,5 / 6,60 151 400 4 55/F 220/380 14,5 / 8,30 182 400 5,5 55/F 220/380 19,2 / 11,00 194 400 7,5 55/F 220/380 25,4 / 14,6 143 450 2,2 55/F 220/380 8,40 / 4,80 192 450 3 55/F 220/380 11,5 / 6,60 223 450 4 55/F 220/380 14,5 / 8,30 235 450 5,5 55/F 220/380 19,2 / 11,00 192 450 7,5 55/F 220/380 25,4 / 14,6 223 w w w. t e c n o v e n t i l . c o m VER. 30/08/10 We reserve the right to make any modifications without prior notice. 9 CVTR Enclosed fans Electrical connections Wiring diagrams Single phase motor, with no anti-clockwise rotation Single phase motor, with no clockwise rotation LINE 1x230V, 50Hz LINE 1x230V, 50Hz Three phase single speed motor Triangular connection (low voltage) Three phase single speed motor Star connection (high voltage) L1 L1 W2 V2 U2 W2 L1 L2 L2 L1 W1 V2 U1 V1 W1 U1 U1 W1 U2 V2 L3 L2 L3 U2 GIALLO/VERDE Rotazione oraria Rotazione antiooraria V1 GIALLO/VERDE U1 W2 V1 L2 L1 V2 W1 V1 L3 L3 L2 U2 W2 L2 Three phase two speed – Single voltage 6 terminals – Dual winding L1 L1 V2 U1 V1 W1 L1 U2 V2 U1 V1 W1 W2 U1 W1 V1 L3 L3 L2 W2 GIALLO/VERDE U2 GIALLO/VERDE W2 V2 U2 L3 L2 L1 L2 L2 L3 Lower speed Higher speed Three phase two speed – Dual voltage 12 terminals – Dual winding Alto voltaggio W2 U1 V1 W2 W1 U1 V1 W1 L2 L3 L1 W2 U2 V2 U1 V1 W1 L2 W2 L3 Low voltage 10 VER. 30/08/10 We reserve the right to make any modifications without prior notice. V1 L1 W1 V1 L2 W2 W1 L3 V2 U2 U1 V2 U2 U1 W2 V1 U2 U1 L1 W1 V2 V1 L2 W1 GIALLO/VERDE V2 V2 U2 U1 W1 Basso voltaggio GIALLO/VERDE U2 V1 GIALLO/VERDE W2 W2 V2 U2 U1 GIALLO/VERDE L1 V2 U2 Alto voltaggio Basso voltaggio L3 High voltage w w w. t e c n o v e n t i l . c o m Enclosed fans w w w. t e c n o v e n t i l . c o m CVTR VER. 30/08/10 We reserve the right to make any modifications without prior notice. 11 CVTR 12 Enclosed fans VER. 30/08/10 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m components for air-conditioning systems tecno-ventil s.p.a. Via Parma, 2 2 6 0 1 6 S p i n o d ’A d d a ( C R ) Te l . + 3 9 0 3 7 3 . 9 8 0 4 5 6 Fa x + 3 9 0 3 7 3 . 9 8 0 6 8 1 w w w. t e c n ove n t i l . c o m [email protected]