Slajd 1 - Janrom
Transcription
Slajd 1 - Janrom
Our company was established in 2002 • • • • • We developing concepts and advise Designing Estimating cost Instaling & programing We service From conception to implementation Fire alarm system SAP Voice alarm system DSO Gravitional smoke removal system Ventilation control system Extinguishing control sytem Fireproof systems of installation transition Immunization of buildings construction Telecommunication instalations LAN, CCTV, SSWiN+KD and other applicable in public buildings Buildings safety Esser – IQ8 Control Bosch Security System (SAP FPA 5000, DSO Praesideo, Plena) ADI International – SAP Algorinet, DSO Sinaps Siemens – Synova, Algorex ADT – SAP Zettler, DSO Audix GE Interlogix – FAP Polon Alfa - SAP Polon seria 4000 D+H i Mercor Ambient System – Schrack, Venas QUALIFICATIONS AND TRAINING REALIZED INVESTMENTS PGE ARENA GDAŃSK POLAND STADIUM ON EURO 2012 Hotel "D" ARKA-MEGA Kolobrzeg Poland design and construction of a comprehensive fire protection fire alarm system SAP, Voice Alarm System DSO, smoke ventilation systems and staircases gravity control Hotel used as the headquarters of the Danish football team during championship Euro 2012 REFERENCE I hereby give reference letter JANROM company based in Gdansk Brylantowa Street 2-3. Company Janrom performed for our low-current systems, fire protection systems - fire alarm, voice alarm system and burglar alarm system. These installations have been performed at the Old Brewery Kosciuszko Street in Poznan. The Company has complied with its scope was exemplary despite numerous changes in decision-making on the part of the investor and documentation discrepancies. The Company has prepared a fire alarm system to the building management together with BMS and BMS contractor led to the overall acceptance of works. CD i DN in Szczecin Bosch FPA 500 + control, LAN, CCTV, automatic. PAZIM Sp. z o.o. Plac Rodła 8, 70-419 Szczecin We prepared project and assembly fire resistant seals and installation transition on the border of fire zones to the order of main contractor ERBUD S.A. Szczecin ul. Mostnika 22. Doll Theater „PLECIUGA” Szczecin, Plac Teatralny 1 We prepared executive project and implemented : SAP, CCTV, SSWiN and LAN with telephone exchange. We also made hardening of building steel construction by fire retardant paint and fire-resistant seal of transitions and joints at the borders zones of fire commissioned by main contractor ERBUD S.A. Szczecin, ul. Mostnika 22. Despite of difficulties during investor reception( by ECE SA Warszawa) Our company completed work without fault. ARKADA Office Poznań, Obornicka Street 229 – We prepared executive project and electromagnetic installation (transformer station, switching SN 15kV, switching NN, automatic SZR) and all low voltage installations (fire alarm system, CCTV, structural network, anti-theft system). Commissioned by main contractor ERBUD S.A. Poznań department. Shopping Gallery CH TURZYN Szczecin Museum of Technology Szczecin fire alarm system Esser, CCTV, LAN, system intrusion and other Shopping Gallery PIAST Szczecin gravity smoke extraction in the roof Petrobaltic Gdańsk Fire Alarm System Bosch FPA 5000 + automatic control HORIZON Gdańsk Przymorze apartment - design and construction of fire-resistant sealing system passages fire zones on the border on behalf of the main contractor EKOLAN SA Gdynia, ul. Wielkokacka 2nd Covered market „Pod Wieżą” in Słupsk Project, assembly and starting the notification system of the fire with assembly of gates and firefighting door steered by anti-fire system , smoke removal system and acoustic alarm system Jantar Gallery in Słupsk FAS Esser i VAS Bosch Preasideo help in execution Paulinum Palace in Jelenia Góra FAS Sagitta 100 + automatic control Apollo Residence in Karpacz FAS Sagitta 100 + automatic control Alma Market Sopot Sikorskiego 8-10 – SAP ul. Polon 4000; projekt i wykonanie uszczelnień ognioodpornych przejść instalacyjnych na granicy stref pożarowych na zlecenie głównego wykonawcy IXO Serwis 47-200, Kędzierzyn - Koźle, Piastowska 40. Hotel Rejs w Ustce FAS Bosch FPA 5000 + automatic control Regional Hospital in Slupsk fireproof sealing sanitary State Higher Vocational School Elbl Sanatorium Centre Klimczok FAS Polon Alfa + gravity smoke extraction Ustronie Morskie FAS Bosch FPA 5000 Aquapark FALA Łodź FAS Bosch FPA 5000 + gravity smoke extraction Hotel „Wodnik” Łeba FAS Polon 4000 - design and implementation of a comprehensive fire protection Sanatorium Centre Natura Tour Radość Ustka - design and implementation of a comprehensive fire protection - fire alarm system FAS Bosch FPA5000, VAS Voice Alarm System.Bosch Northern Shipyard Gdańsk D+H Smoke Control Seaport customs clearance in Elblag - making comprehensive fire protection systems. and CCTV, burglar alarm system and access control systems - installation and commissioning Elementary School Gym Lidzbark Warminski Fire hardening steel structure We train and improve ourselves We train and improve ourselves