Desoutter Air Motor Catalogue
Transcription
Desoutter Air Motor Catalogue
TM Air Motors Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 Air Motors TM Introduction 2. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 Air motors are versatile power sources which can be used to power many kinds of operations requiring a rotational drive. They have many advantages over electric motors, and often become the only feasible method of operation. Advantages Desoutter offers a wide range of rotating vane type air motors within a power range of 0.26 kW (0.35 hp) to 0.66 kW (0.85 hp). Most motors can be supplied as single rotation or reversible. Reversible motors have keyed shafts, while single direction motors can be supplied with threaded shafts or alternatives. 1. Compact, with high power to weight ratio. An air motor will often be one third or less than the size of a comparable electric motor. An air motor can be used in a portable application where the weight and/or physical size of the electric motor would preclude portable operations. For example, a 0.63 kW (0.85 hp) air motor running at 2000 rpm weighs 1.4 kg (3 lbs) and is approximately 200mm (8") long and just over 50mm (2") in diameter. 2. The output speed and torque can be simply controlled by regulating either the air pressure or air flow. No expensive control equipment is required. 3. If a motor is loaded to a stalled condition, and held there for any length of time, no damage is caused to the motor. In certain applications, such as tightening fasteners, one acceptable method of control is to regulate the air pressure so that the motor stalls at the required torque. 4. When the load is released, the air motor will reach free running speed usually within one third to one half of a revolution. 5. No risk of overheating either when continuously run or frequent stop/starts or reversing. Note that this condition assumes the use of an inline lubrication system. 6. Reversing motors require simple control of air pressure into ports in the control top of the motor to determine direction of rotation. To reverse the direction of rotation takes milliseconds to complete. 7. Resists moisture, dust, heat. Is generally explosion proof and can be used safely in most hazardous situations. Terms The following terminology is used in this publication: No load speed – maximum speed attained at a given air pressure under a no-load condition. Maximum power – with a vane type air motor, the maximum power output is achieved at nearly one half of the no load speed. This is the point at which the motor will run most efficiently. Dynamic torque – the output torque of the motor at any stage during the operating cycle. The dynamic torque increases virtually in a straight line from zero at no load to a maximum at the stalled condition. Stall torque – output torque achieved when the load applied causes the motor to stall. Starting torque – to obtain the proper sealing of the rotor blades against the cylinder walls for maximum efficiency, and to overcome inertia, it takes more torque to start an air motor than when it is running. Starting torque is approximately 75% of stall torque. Air consumption – measured in the no-load condition. Air consumption is maximum at no load, and is approximately three quarters of this figure at maximum power. Air consumption reduces as the working air pressure is reduced. For example at 50 p.s.i. the air consumption is almost one half that at 90 p.s.i. Performance specifications – are normally shown with an air inlet pressure of 6.3 bar at the air motor, unless otherwise stated. Note that there is approximately a 14% drop in power for every 10% reduction in air inlet pressure. Rotation – non-reversible motors rotate in a clockwise direction if the motor is viewed from the air inlet end with the spindle pointing away from you. Contents TM 3. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 Contents 4 5 Selecting an Air Motor DM6/DM65 Series (0.26 kW, Non Reversible, Torque 0 - 8 Nm) 6 2DM6 Series (0.26 kW, Reversible, Torque 0 - 8 Nm) 7 HM Series (0.45 kW, Non Reversible, Torque 0 - 41 Nm) 8 HM55 Series (0.63 kW, Non Reversible, Torque 0 - 41 Nm) 9 2HM5 Series (0.66 kW, Reversible, Torque 0 - 41 Nm) 10 2H410 Series (0.66 kW, Reversible, Worm Drive) 11 Air Motors for Special Applications and Application Questionnaire 12 Air Motor Accessories 15 Air Motor Control Equipment General Information • Air Motors are supplied as “Machinery to be incorporated” – Customer is responsible for safe incorporation into the complete machine. • Always refer to Operating and Warning instructions supplied with the tool before operating the tool. • All accessories and those tools marked with an asterisk (*) are supplied outside the scope of Desoutter Ltd’s ISO9001 registration, but are sourced from firms meeting Desoutter Ltd’s supplier quality assurance requirements. • Sound levels quoted in this catalogue were obtained from measurements made according to the CAGI-PNEUROP Test Code. Nominal values are quoted, sound levels of individual tools may vary by ±2dB(A). Selecting an Air Motor TM 4. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 After first determining whether a single direction or a reversible motor is required, the next step is to consider the required output speed and torque together with the operational conditions. As a general rule try to select a motor with twice the free running speed of the speed required under load. By using the performance graphs indicated on the following pages it is then possible to ensure that the motor meets the requirements specified. Example: What motor is required to produce an output torque of 6 Nm at 300 rpm. The motor should be reversible and 6 bar supply pressure is available. Step One – Select the motor type The maximum dynamic torque of the DM Series motor is 8 Nm. Since a reversible motor is required the 2DM6 will be used. Step Two – Select the appropriate motor speed As a rule try to select a motor with twice the free running speed of the speed required since this will usually coincide with the high power band of the motor. Step Three – Confirm the motor is suitable for the application By plotting both the torque (6 Nm) and speed (300 rpm) on the graph an intersection is found. Provided the intersection is below the torque line for the motor (straight line) then the motor is suitable for the application. For this example we require 300 rpm so use a motor of about 600 rpm free running speed. The closest is 620 rpm so try the 2DM6-620. 2DM6 Series Air Motors * * * * * * * 7 4 2.5 1.2 0.6 0.3 * * * * * * * 5.85 3.34 2.05 1 0.5 0.25 * * * * * * 8 4.68 2.67 1.64 0.8 0.4 0.2 * * * * * * 6 3.51 2 1.23 0.6 0.3 0.15 * * * * * 6.66 4 2.34 1.64 0.82 0.4 0.2 * Dynamic torque must not exceed 8 Nm (5.9lbf ft). 0.1 0.05 Power kW 0 0 0 0 0 0 0 0 0 0 0 0 0 Torque Nm Power at an inlet pressure of 6.3 bar. * * * 5.83 5 3.33 2 1.17 0.67 0.41 0.2 0.1 45 60 90 290 390 620 960 1650 2700 4200 9000 16000 Reversible 0 0 0 0 0 0 0 0 0 0 0 0 2000 1100 400 300 180 110 66 40 30 10 6 5 4000 2200 800 600 360 220 130 90 70 20 13 10 6000 3300 1300 900 540 330 200 130 100 30 20 15 8000 4400 1800 1200 720 440 260 180 130 40 26 20 10000 5500 2300 1500 900 550 330 220 170 50 33 25 Speed r/min 12000 6600 2700 1800 1060 660 400 260 200 60 40 30 14000 7700 3200 2100 1260 770 460 310 230 70 46 35 16000 8800 3600 2400 1440 880 530 350 270 80 53 40 18000 9900 4000 2700 1620 990 600 400 300 90 60 45 16000 9000 4200 2700 1650 980 620 390 290 90 60 45 DM6, DM65 Series Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 DM6, DM65 Series 0.26 kw (0.35 hp), Maximum Torque 8 Nm (5.9 lbf ft), Non Reversible MOTOR TYPE THREADED SHAFT THREADED NOSE / DM6-16000T DM6-9000T DM6-4200T DM6-2700T DM6-1650T DM6-980T DM6-620T DM6-390T DM6-290T DM6-90T DM6-60T DM6-45T NO LOAD SPEED MAX. POWER TORQUE AT MAX. POWER AIR CONSUMPTION AT MAX. POWER MIN. HOSE BORE WEIGHT SOUND LEVEL r/min. kW Nm l/s mm kg dB(A) 0.26 0.23 0.4 1.2 1.8 3 5 8 8 8 8 8 8 10 0.65 0.65 0.65 0.65 0.75 0.75 0.75 0.75 0.83 0.83 0.83 0.93 76 16000 9000 4200 2700 1650 980 620 390 290 90 60 45 9.4 Power at an inlet pressure of 6.3 bar. * Dynamic torque must not exceed 8 Nm (5.9lbf ft). * * * * * * * 7 4 2.5 1.2 0.6 45 60 90 290 390 620 960 1650 2700 4200 9000 16000 DM65-16000T DM65-9000T DM65-4200T DM65-2700T DM65-1650T DM65-980T DM65-620T DM65-390T DM65-290T DM65-90T DM65-60T DM65-45T KEYED SHAFT / THREADED NOSE * * * * * * * 5.85 3.34 2.05 1 0.5 0.3 * * * * * * 6 3.51 2 1.23 0.6 0.3 0.25 Power 0.2 0.15 * * * * * 6.66 4 2.34 1.64 0.82 0.4 0.2 4b ar (58 psi ) Power kW 0.1 2 ba r (24 psi) * * * 5.83 5 3.33 2 1.17 0.67 0.41 0.2 0.1 0.05 0 0 0 0 0 0 0 0 0 0 0 0 0 2000 1100 400 300 180 110 66 40 30 10 6 5 4000 2200 800 600 360 220 130 90 70 20 13 10 6000 3300 1300 900 540 330 200 130 100 30 20 15 8000 4400 1800 1200 720 440 260 180 130 40 26 20 10000 5500 2300 1500 900 550 330 220 170 50 33 25 12000 6600 2700 1800 1060 660 400 260 200 60 40 30 14000 7700 3200 2100 1260 770 460 310 230 70 46 35 16000 8800 3600 2400 1440 880 530 350 270 80 53 40 18000 9900 4000 2700 1620 990 600 400 300 90 60 45 16000 9000 4200 2700 1650 980 620 390 290 90 60 45 Speed r/min Max Loading 550N DM6-T Exhaust Collector can be mounted with silencer facing in either direction and rotated through 360° - 1/4" BSP thread. 1/8" BSP Air inlet 3 Ø10(h6) M35 x 1.0 L.H. 12 7 45 Ø36 1.2 13 Optional Adaptor for 1/8" NPT Air Inlet 23.5 40.5 Tapped hole M4 x 13 3 14 A Ø38 38 7 DM65-T M35 x 1.0 L.H. Torque Nm * * * * * * 8 4.68 2.67 1.64 0.8 0.4 To rqu e 6b ar (87 psi ) 0 0 0 0 0 0 0 0 0 0 0 0 5. TM 12 3/8" X 24 UNF 35 3 All dimensions in mm unless specified otherwise SPEED A 16000, 4200, 2700 9000 1650, 980, 620, 390 290, 90, 60 45 130.0 163.4 152.0 170.0 188.2 2DM6 Series TM 6. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 2DM6 Series 0.26 kw (0.35 hp), Maximum Torque 8 Nm (5.9 lbf ft), Reversible MOTOR TYPE 2DM6-16000 2DM6-9000 2DM6-4200 2DM6-2700 2DM6-1650 2DM6-980 2DM6-620 2DM6-390 2DM6-290 2DM6-90 2DM6-60 2DM6-45 MAX. POWER TORQUE AT1) MAX. POWER AIR CONSUMPTION AT MAX. POWER MIN. HOSE BORE WEIGHT SOUND r/min. kW Nm l/s mm kg dB(A) 0.26 0.23 0.4 1.2 1.8 3 5 8 8 8 8 8 8 10 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.78 0.78 0.78 0.88 731) 16000 9000 4200 2700 1650 980 620 390 290 90 60 45 9.4 It is recommended that a suitable air diffuser is fitted downstream of any control valve through which exhaust air exits. Power at an inlet pressure of 6.3 bar. * Dynamic torque must not exceed 8 Nm (5.9lbf ft). * * * * * * * 7 4 2.5 1.2 0.6 45 60 90 290 390 620 960 1650 2700 4200 9000 16000 1) NO LOAD SPEED * * * * * * * 5.85 3.34 2.05 1 0.5 0.3 * * * * * * 6 3.51 2 1.23 0.6 0.3 4b 0.25 Power 0.2 0.15 ar ( 58p * * * * * 6.66 4 2.34 1.64 0.82 0.4 0.2 si) Power kW Torque Nm * * * * * * 8 4.68 2.67 1.64 0.8 0.4 To rq 6 b ue ar (87 psi ) 0.1 * * * 5.83 5 3.33 2 1.17 0.67 0.41 0.2 0.1 2 bar (2 9psi) 0.05 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2000 1100 400 300 180 110 66 40 30 10 6 5 4000 2200 800 600 360 220 130 90 70 20 13 10 6000 3300 1300 900 540 330 200 130 100 30 20 15 8000 4400 1800 1200 720 440 260 180 130 40 26 20 10000 5500 2300 1500 900 550 330 220 170 50 33 25 12000 6600 2700 1800 1060 660 400 260 200 60 40 30 14000 7700 3200 2100 1260 770 460 310 230 70 46 35 16000 8800 3600 2400 1440 880 530 350 270 80 53 40 18000 9900 4000 2700 1620 990 600 400 300 90 60 45 16000 9000 4200 2700 1650 980 620 390 290 90 60 45 Speed r/min max. loading 550N Ø38 Ø7 12 60 3 Ø10(h6) 48CRS Forward Optional Adaptor for 1/8" NPT Air Inlet Reverse Tapped hole M4 X 13 1.2 Air inlet Forward Rotation 9.2 9 Ø37 (f7) 3 Air Inlet Reverse Rotation 9.2 Ø36 5.2 13 23.5 3 Ports 1/8" BSP 29(f7) Note: Exhaust is through common exhaust port and opposite rotation inlet port. Blocking or restricting these ports will reduce the performance of the motor. 14 24.5 36 Exhaust 7.5 A All dimensions in mm unless specified otherwise SPEED A 16000, 4200, 2700 9000 1650, 980, 620, 390 290, 90, 60 45 127.1 160.5 149.1 167.1 185.3 HM Series Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 HM Series 0.45 kw (0.6 hp), Maximum Torque 41 Nm (30 lbf ft), Non Reversible MOTOR TYPE HM-4600 HM-2850 HM-1900 HM-830 HM-500 HM-340 HM-90 HM-60 NO LOAD SPEED MAX. POWER TORQUE AT MAX. POWER AIR CONSUMPTION AT MAX. POWER MIN. HOSE BORE WEIGHT SOUND r/min. kW Nm l/s mm kg dB(A) 0.45 2.0 3.0 4.5 10.4 16.8 25 41 41 10 1.1 1.1 1.1 1.6 1.6 1.6 1.9 1.9 82 4600 2850 1900 830 500 340 90 60 13 * Dynamic torque must not exceed 41 Nm (30lbf ft). To rqu e * * * 32.40 20.00 8.70 5.80 3.60 60 90 340 500 830 1900 2850 4600 Power at an inlet pressure of 6.3 bar. * * 29.10 19.44 12.00 5.22 3.48 2.16 0.5 Power (87 ps i) 0.4 0.3 4b ar (58 * * 19.40 12.96 8.00 3.48 2.32 1.44 psi 2b * 37.40 9.70 6.48 4.00 1.74 1.16 0.72 ar ( ) Power kW 0.2 29p 0.1 si) 0 0 0 0 0 0 0 0 0 557 345 230 100 62 41 11 7 1114 690 460 200 123 82 21 14 1670 1034 690 300 185 124 32 21 2227 1379 920 400 247 165 43 29 2782 1724 1149 500 309 206 53 36 3339 2069 1379 600 370 247 64 43 3895 2414 1609 700 432 289 75 50 4452 2759 1839 800 494 330 86 57 4600 2850 1900 830 500 340 90 60 Speed r/min Ø9 15.5 9.5 Air inlet 1/4" BSP (1/4" NPT optional) Ø 47.5 70 CRS 89 Ø 49.2 (f7) 11/2" X 20 TPI LH Ø 62 12.7 HM-4600 HM-2850 HM-1900 11/2" X 20 UNF 56 51 9 26.5 14 10 4.8 A 14 Ø9 16 Exhaust 9 5/8" X 9.5 4.8 A All dimensions in mm unless specified otherwise HM-830 HM-500 HM-340 HM-90 HM-60 16 UN 56 51 Ø 62 Ø 47.5 89 70 CRS 15/8" X 16 TPI LH Ø 49.2 (f7) Torque Nm * * 38.80 25.92 16.00 6.96 4.64 2.87 6b ar 0 0 0 0 0 0 0 0 7. TM 26.5 14 10 SPEED A HM-4600, 2850, 1900 111.3 HM-830, 500, 340 156.3 HM-90, 60 193.3 HM55 Series TM 8. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 HM 55 Series 0.63 kw (0.85 hp), Maximum Torque 41 Nm (30 lbf ft), Non Reversible THREADED SHAFT MAX. POWER TORQUE AT MAX. POWER AIR CONSUMPTION AT MAX. POWER MIN. HOSE BORE WEIGHT SOUND r/min. kW Nm l/s mm kg dB(A) 0.63 0.60 3.5 5.2 12.0 19.4 29.1 41 41 41 10 1.4 1.4 1.4 1.7 1.7 1.7 2.1 2.1 2.1 78 18000 3300 2100 950 550 350 150 100 40 15.5 Power at an inlet pressure of 6 bar. 40 100 150 350 550 950 2100 3300 18000 HM55-18000 HM55-3300 HM55-2100 HM55-950 HM55-550 HM55-350 HM55-150 HM55-100 HM55-40 NO LOAD SPEED * * * * * 28.00 12.18 8.12 1.40 * Dynamic torque must not exceed 41 Nm (30lbf ft). * * * * 38.88 24.00 10.44 6.96 1.20 0.7 0.5 * * * 38.80 25.92 16.00 6.96 4.64 0.80 * * * * 32.40 20.00 8.70 5.80 1.00 Power 0.4 0.3 (58 psi ) * * * 19.40 12.96 8.00 3.48 2.32 0.40 * * * 29.10 19.44 12.00 5.22 3.48 0.60 4b ar Power kW 0.2 * 37.40 23.00 9.70 6.48 4.00 1.74 1.16 0.20 2b ar ( 29p si) 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2000 345 230 100 62 41 17 11 5 4000 690 460 200 123 82 35 21 10 6000 1034 690 300 185 124 52 32 14 8000 1379 920 400 247 165 70 43 19 10000 1724 1149 500 309 206 87 53 24 12000 2069 1379 600 370 247 104 64 29 14000 2414 1609 700 432 289 122 75 33 16000 2759 1839 800 494 330 139 86 38 18000 3103 2069 900 556 371 157 96 43 18000 3300 2100 950 550 350 150 100 40 Speed r/min C Exhaust Collector can be mounted with silencer facing in either direction and rotated through 360° - 1/4" BSP thread. Ø53(f8) B Ø25.4 Ø40(h6) D Ø52 Ø9 70 CRS Torque Nm 0.6 To rqu e 6b ar (87 psi ) 4.5 21.5 A/F 4.5 10 4.7 Ø54 A 54.5 Air Inlet 1/4 " BSP (1/4" NPT Optional) MOTOR TYPE A THREAD B 18000 159 1/2" x 20 UNF 2100, 3300 350, 550, 950 196.5 5/8" x 16 UN 40, 100, 150 234 5/8" x 16 UN C D 23.3 12.3 28.4 16.2 28.4 16.2 2HM5 Series 9. TM Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 2HM5 Series 0.66 kw (0.85 hp), Maximum Torque 41 Nm (30 lbf ft), Reversible MOTOR TYPE MAX. POWER TORQUE AT MAX. POWER AIR CONSUMPTION AT MAX. POWER MIN. HOSE BORE WEIGHT SOUND r/min. kW Nm l/s mm kg dB(A) 0.65 0.65 3.8 5.6 13 21 31.5 41 41 41 10 1.4 1.4 1.4 1.7 1.7 1.7 2.1 2.1 2.1 87 18000 3300 2100 950 550 350 150 100 40 16.5 Power at an inlet pressure of 6 bar. * Dynamic torque must not exceed 41 Nm (30lbf ft). * * * * * 28.00 12.18 8.12 1.40 40 100 150 350 550 950 2100 3300 18000 2HM5-18000 2HM5-3300 2HM5-2100 2HM5-950 2HM5-550 2HM5-350 2HM5-150 2HM5-100 2HM5-40 NO LOAD SPEED 0.7 * * * * 38.88 24.00 10.44 6.96 1.20 To rq 6b ar ue 7p 0.5 * * * 38.80 25.92 16.00 6.96 4.64 0.80 * * * * 32.40 20.00 8.70 5.80 1.00 si) 0.4 ar (58 psi 0.3 ) * * * 19.40 12.96 8.00 3.48 2.32 0.40 * * * 29.10 19.44 12.00 5.22 3.48 0.60 4b Power kW Torque Nm 0.6 Power (8 0.2 2b ar ( * 37.40 23.00 9.70 6.48 4.00 1.74 1.16 0.20 29p si) 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2000 345 230 100 62 41 17 11 5 4000 690 460 200 123 82 35 21 10 6000 1034 690 300 185 124 52 32 14 8000 1379 920 400 247 165 70 43 19 10000 1724 1149 500 309 206 87 53 24 12000 2069 1379 600 370 247 104 64 29 14000 2414 1609 700 432 289 122 75 33 16000 2759 1839 800 494 330 139 86 38 18000 3103 2069 900 556 371 157 96 43 18000 3300 2100 950 550 350 150 100 40 Speed r/min Ø54 30 Ø9 Ø52 Ø53 (f8) C D ØB Ø17 Ø40 (h6) 70 CRS 90 Forward Note: Exhaust is through common exhaust port and opposite rotation inlet port. Blocking or restricting these ports will reduce the performance of the motor. Reverse 3 Ports 1/4" BSP (1/4" NPT Optional) Trapped hole 'E' 20 4.5 Exhaust 10 4.5 35 4.7 A 13 CRS All dimensions in mm unless specified otherwise MOTOR TYPE 8 Air Inlet Forward Rotation 13 13 Air Inlet Reverse Rotation A B(h6) C 18000 143.5 12 2100, 3300 350, 550, 950 187 14 40, 100, 150 224.5 14 D E 1.5 4 M4 2 2 5 5 M5 M5 TM 2H410 Series 10. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 2H410 Series 0.66 kw (0.85 hp), Maximum Torque 106 Nm (78 lbf ft), Worm Drive Motors MOTOR TYPE 2H410-500 2H410-350 2H410-150 2H410-90 2H410-60 NO LOAD SPEED MAX. POWER MAX. STALL TORQUE MIN. SAFE WORKING PRESSURE MAX. AIR CONSUMPTION MIN. HOSE BORE WEIGHT SOUND r/min kW Nm bar l/s mm kg dB(A) 0.66 39 51 102 102 102 6 6 6 4 2.8 17 17 17 10 9 12 12 12 10 10 1.7 1.7 2.0 2.0 2.0 87 500 350 150 90 60 A version of the 2HM5 motor can be supplied equipped with a worm drive gearbox, allowing the drive to be taken from each side of the head for either right hand or left hand rotation. Standard drive is a .525" A/F Female Hexagon, but adaptors can be supplied to convert this to either 3/8" or 1/2" square drive. An alternative head is available to provide a No. 1 morse taper drive. A 68.3 Note: Exhaust is through common exhaust port and opposite rotation inlet port. Blocking or restricting these ports will reduce the performance of the motor. B 21.6 18 Exhaust Port 3/8"BSP RAD Ø 52.1 52.1 26 2 527" A/F Interna Hexagon Thro Ø 50.8 Left Hand Rotation This Side Right Hand Rotation This Side 30.7 9.5 Reverse Port Forward Port 1/4"BSP 1/4"BSP Ø 51.6 TYPE SPEED A B 2H410-500 2H410-350 2H410-150 2H410-90 2H410-60 500 350 150 90 60 208.8 208.8 245.9 245.9 245.9 118.9 118.9 156.0 156.0 156.0 Special Applications and Application Questionnaire 11. TM Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 Special Applications Desoutter can produce special motors to specifically suit your application whether through modification of the control method or output drive. Please provide details should your application require a special type. Selection Questionnaire The following questionnaire is for use either by the engineer for his/her own calculations or can be completed and returned to the local Desoutter Sales Office. Specification Torque Required Nm Speed Required RPM Rotation Output Type (to convert lbfft to Nm x 1.356) Forward Reverse Reversible Keyed (DM6-T/2DM6/2HM5) Threaded (DM65-T/HM55/HM only) 0.525" Hexagon (2H410 only) bar (to convert psi to bar x 14.504) Air Line Pressure Lubrication Available Yes No Number of Motors Required OFFICE USE ONLY Recommended Motor Type OFFICE USE ONLY Accessories (see pages 12-15) Recommended Accessories Chucks Collet Holders Screwdriver Bit Adaptor Flange (DM6/65-T) Exhaust Collector (HM) Stands Air Service Equipment Air Line Hoses Output Accessories TM 12. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 Key Adjustable Chucks MOTOR TYPE CHUCK CAPACITY CHUCK AND KEY mm part no. 6.5 8 10 28942 94502 31132 HM-1900-4600 HM55-2100-18000 13 29142 HM-60-830 HM55-40-950 13 29122 DM65-T Collet Chucks MOTOR TYPE LENGTH DIA. 1 2 mm mm part no part no 26932 26942 42 15.2 26932 26952 DM65-T HM-1900-4600 HM55-2100-18000 COLLETS mm part no. mm part no. mm part no. mm part no. 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 2892 2902 2912 2922 2932 2942 2952 2962 2972 2982 2992 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3002 3012 3022 3032 3042 3052 3062 3072 3082 3092 3102 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4.0 3112 3122 3132 3142 3152 3162 3172 3182 3192 3202 3212 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5.0 3222 3232 3242 3252 3262 3272 3282 3292 3302 3312 Fixed Collet Drives DIAMETER MOTOR TYPE 6mm 1/4" DM65-T DRIVE MOTOR TYPE LENGTH DIA. COLLET NUT mm mm part no. part no. 41.3 41.3 21 21 22362 22382 22352 22352 Screwdriver Bit Adaptor 5/16" fem. DM65-T LENGTH DIA. mm mm part no. 35 13 27532 Thread Adaptor MOTOR TYPE A B DM65-T 3/8" x 24 UNF 1/2" x 20 UN part no. A B 68143 Output Accessories 13. TM Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 Flange for DM6/65-T R8 2 HOLES Ø7 Ø 38 Ø 44.5 20.0 17 13 16 7.1 4.1 73.2 M35 -1.O LH 6H Ø41.22 Ø41.28 Part No. 286423 5.5 Ø37.0 4.5 M35 -1.O LH 6H Part No. 441653 Ø41.224 Ø41.275 Ø37.0 Ø34.90 Ø34.85 8 44.5 M35x1.OP LH 6H 390683/390693 – 15 441653 – 19 Part No. 390683 M35x1.OP LH 6H Ø37.0 Part No. 390693 7.9 RAD 57.2 CRS. 57.15 50.8 44.5 20.0 17 13 2 HOLES Ø7 R6 48 CRS. 2 HOLES Ø7 Ø28.98 Ø28.96 2 HOLES Ø7 R8 7.5 8 2.29 Part No. 390683 provides same mounting dimensions as DM – 17700/5300/4000/3000/1600 Part No. 390693 provides same mounting dimensions as DM – 900/500/210/80/40 Part No. 441653 provides same mounting dimensions as DM6 and DM65 motors Exhaust Collector Ring for HM Series Part No. 43093 Part No. 72163 CONNECTION PART NO. Ø15mm barb 3/8" BSP Female 43093 72163 Stands R55 Lever Operated Stand for HM Series Note: Motor must be fitted with exhaust collector ring (see above) 203mm 31.8mm (1.25") 453mm 235mm 203mm 127mm 42mm 12.7mm Part No. 903304 Air Motor Accessories TM 14. Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 D54 Lever-Operated Stand R55-S Lever-Operated Stand For DM6, DM65 and 2DM6 Motor Part No. 901944 Weight: 7 kg Max. Stroke: 45mm Part No. 903644 Weight: 11.32 kg Max. Stroke: 57mm Max. Mounting Plate Load: 6 kg 290 38 610 approx. 58.5 Height Adjustment 405 SelfStart plunger 255 Mounting Plate Height Adjustment Stroke Adjustment 76 322 Max. approx 38 Stroke Adjustment 73 178 25.4 19 172 42 203 9.5 41.3 44.5 102 19 44.5 209 19 25.4 102 203 9.5 51 127 19 51 12.7 235 Ø32 102 100 12.7 M55A Lever-Operated Stand MC55 Cylinder-Operated Stand With Linear Bearings With Linear Bearings Part No. 902594 Weight: 16 kg Max. Stroke: 65mm Max. Mounting Plate Load: 7.25 kg Part No. 902914 Weight: 32 kg Max. Stroke: 100mm Max. Mounting Plate Load: 68 kg 380 Standard 230 Optional 220 1041 approx. 50 SelfStart plunger 250 Mounting Plate Height Adjustment 90 1020 179 Stroke Adjustment Max 743 approx. 178 250 646 Max approx. 40 51 40 51 358 358 Ø30 Ø30 312 312 305 102 157 12.7 335 305 102 157 12.7 335 Control Equipment 15. TM Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR telephone +44 1442 344300 facsimile +44 1442 344604 Operating the Motor A Typical Control Circuit To obtain the longest life span of the vane type air motor, it is recommended that a clean, dry supply of air in sufficient quantity is supplied, with an automatic lubrication system to provide the correct amount of lubrication to the air motor at all times. Reversible Motor Control Valve Forward Port Flow Regulators Reverse Port Controlling the motor can be achieved using pneumatic valves, either hand, foot, pilot air or solenoid operated. The valve used must have full flow capability to ensure unrestricted air flow to the motor. Exhaust Port Silencer Filter, Regulator, Lubricator Air Supply Torque is controlled by changing the pressure, speed by air flow. Flow Regulators* Reinforced PVC Air Hose* A B C HOSE BORE A THREAD mm PART SIZE PART NO. 1/4" BSP Female 90882 Adaptors* Hose assembly tested to 12.6 bar air pressure. 10 10 12 12 12 1/4" 1/4" 3/8" 1/2" 1/2" BSP BSP BSP BSP BSP B THREAD C LENGTH TYPICAL FLOW PART NO. BSP m l/s 1/4" 1/4" 3/8" 1/2" 1/2" 3 5 3 3 5 14 14 33 33 33 75972 75982 78532 76002 76022 Air Line Service Sets* A Filter, Regulator, Lubricator – Air Preparation unit comprising: Filter-Water Separator Pressure Regulator Oil Mist Lubricator Mounting Bracket B PART SIZE PART NO. RECOMMENDED AIR FLOW l/s A THREAD B THREAD PART NO. 1/8" 1/8" 1/8" 1/4" 1/4" 3/8" 1/4" 1/2" 1/8" 1/8" 1/4" 1/8" 3/8" 1/2" 1/2" 3/4" 271463 61103 209833 209843 62982 62992 63782 63792 BSP NPT NPT BSP BSP BSP BSP BSP NPT BSP BSP BSP BSP BSP BSP BSP 1/4" BSP 3/8" BSP 1/2" BSP 1" BSP For full range ask for Air Service Equipment Catalogue 9092 9092 9092 9092 0062 0007 0015 0020 11 81 31 11 Pressure Gauge 1/8" BSP 0-10 Bar Part No. 9090 1172 00 9 14 31 83
Similar documents
wIrIng products, Inc.
and developing cable TV industry. Since then, the industry has grown in many directions and the technology has advanced to levels that allow more video, voice and data to flow through a cable than ...
More information(Thumpstar) Service Manual
compensates for the initial wear that occurs during the break-in period Sections 1 and 3 apply to the whole motorcycle. Section 2 illustrates what may be required to perform service described in th...
More information