Overview Screens - eLynx Technologies
Transcription
Overview Screens - eLynx Technologies
SCADA-Lynx Functionality Overview August 2006 Overview Screens: Summary Listing - is a customizable overview of any group of wells. From here, the user can perform trending or variance analyses, review and graph individual and well and device data, generate customized reports, export data to Microsoft Excel, and more Roll-Up Variance - Presents a hierarchical view of key performance data, such as production and pressure, for both surveillance and drilldown review. Variance analysis can be performed against prior period averages or imported corporate targets. When a variance is noted, the user can quickly drill down from field to well to device to identify and resolve the problem eLynx Technologies – [email protected] – www.elynxtech.com Trending Screens: Group Trending is a powerful interface for analyzing system-wide production data, because it allows users to trend data from multiple devices in a single graph. Additionally, using calculated trends you can create a trend line that represents the sum or average of values of the same data type across multiple devices. Group Quick Trending – Using a pre-configured Group Trending profile, Group Quick Trend exports trend graphs for every device in the group to a Microsoft Word file. This document can then be printed and used for well reviews. eLynx Technologies – [email protected] – www.elynxtech.com Quick Graphs – Shows a pre-configured trend for every device in the current group. Users can quickly scroll down the page to view the trends. Device Trending - Device trending provides a graphical representation of selected data items and are built using the most recent polled data. Trend parameters are user configurable and can be saved for future use. eLynx Technologies – [email protected] – www.elynxtech.com Reports: Marketing Report – The marketing report pages show previous day’s gas flow by device. Raw Data Reports - eLynx's report engine allows reporting of all data values for configured devices. Reports can be customized and saved for quick access in the future. Report data can also be exported to Microsoft Excel for further use and analysis. eLynx Technologies – [email protected] – www.elynxtech.com Analysis Screens: Device Detail - The Device Details page provides the user with the last known values for all tags associated with the device. Device Alarms – Shows all configured Device Alarm set points and their current status. eLynx Technologies – [email protected] – www.elynxtech.com Device Memos - Shows all associated memos for a device. Additionally, you can add or delete memos from the device. Device memos allow multiple users to journal changes or record information about the device. Live Data and Control - The live data and control screen allows you to interact directly with the device polling drivers behind the application. The data that is presented in this screen is the most current available to the system. Control tags allow new values to be entered and written down to the device. eLynx Technologies – [email protected] – www.elynxtech.com Administration: Alarm Configuration - Exception based alarm notifications are user configurable and notify personnel of conditions that require attention. Alarms can be sent to email, fax, cellular phones, and pagers. Alarm conditions are also highlighted in the user interface indicating a value outside of the configured range. Device Administration - The device administration screen allows you to rename a device, edit or add attributes, and set the default trend parameters. eLynx Technologies – [email protected] – www.elynxtech.com Group Administration - eLynx uses a tree structure for device navigation and grouping. The tree is composed of groups. Groups contain monitored devices. There is no limit to the number of groups or subgroups that you can create. Typically the groups you create will be based on the type of equipment being monitored, and the employees that need access to monitoring data. Page Configuration - The page configuration screen is used to configure data columns for configured devices in the Summary Listing. Page configuration can be saved on a per user and group basis. eLynx Technologies – [email protected] – www.elynxtech.com User Administration - The user administration screen is used to create users and assign permission to those users. The eLynx security model allows site administrators to provide granular security permissions to users for access to groups and devices. Security permission that can be assigned to users include View, Trend, Control, Notification List Administration, Reporting, Field Alarm Configuration, User Administration, Group Administration, List Administration, Database Alarm Configuration, Device Administration. Other: Manual Tag Entry – Allows data to be manually entered for a device or group of devices. eLynx Technologies – [email protected] – www.elynxtech.com Artificial Lift - eLynx web-based monitoring services enable proactive management of controllers for artificial lift technologies including electronic submersible pump, rod pump, and plunger lift. Features include historical trending, statistics, and fault reporting. Production Accounting Integration – eLynx provides data export integration for the following Production Accounting systems: Merrick, Production Access, TOW, and Petris. Key features: • • • • Data Rollback: eLynx works with our clients to ensure that all available data ultimately is submitted to the production accounting system through automated systems. Unique Data Characterization: eLynx generally engineers intrinsically defined data file structures that properly characterize the data submitted to the production accounting system. Data Verification: eLynx can expose custom data verification screens that pass the ownership of data quality closer to the operations personnel. Automated Export Systems: eLynx data exports can be scheduled for multiple submissions per day, with retry logic if necessary. eLynx Technologies – [email protected] – www.elynxtech.com Web Service Data API In order to securely allow customers to access their data from any application (browser or desktop app), eLynx offers a web-service based API. These services can be integrated into custom solutions, or utilized by any third-party application that is SOA aware. All web service data is encrypted (SSL), and access is limited by the standard eLynx user authentication process. Security Overview: Physical Security Our production equipment is located in Tulsa, OK. Our data center has 24-hour physical security, electrical generator, redundant data center air conditioners, and other backup equipment designed to keep servers continually up and running. The site is electronically controlled and monitored on a 24x7x365 basis. Perimeter Defense The network perimeter is protected by multiple firewalls and monitored by intrusion detection systems — all obtained from industry-leading security vendors. In addition, eLynx monitors and analyzes firewall logs to proactively identify security threats. Data Encryption eLynx leverages the strongest encryption products to protect customer data and communications, including 128-bit Verisign SSL Certification. User Authentication Users access eLynx only with a valid username and password combination, which is encrypted via SSL while in transmission. An encrypted session ID cookie is used to uniquely identify each user. Application Security Our application security model prevents one eLynx customer from accessing another's data. This security model is reapplied with every request and enforced for the entire duration of a user session. Database Security Every eLynx customer has a dedicated database for increased security. Access to production databases is restricted to a limited number of points, and production databases do not share a master password database. eLynx Technologies – [email protected] – www.elynxtech.com Reliability and Backup All Internet networking components and web servers are configured in a redundant configuration. All customer data is stored on a database served by a database server cluster for redundancy. All customer data is stored using RAID disks and multiple data paths. All customer data, up to the last committed transaction, is automatically backed up to a primary tape library on a nightly basis. Backup tapes are moved to secure, fire-resistant, off-site storage on a regular basis. Disaster Recovery eLynx has an agreement in place with a third party provider for dedicated space in a second data center for disaster recovery. eLynx has provided hardware, software, and Internet connectivity at the second data center to ensure a quick recovery in the event our production facility were rendered unavailable. SCADA-Lynx Remote Polling Interface The RPI software interacts with many different types of native polling hosts and local SCADA systems. It is installed on your polling host, where it subscribes to the production data and transmits it back to the SCADA-LYNX host in a secure encrypted format. You continue to operate your polling host in the same manner as always, including scheduling and adding new monitored points. The integration to the eLynx system is transparent, and the result is a secure site that allows all authorized personnel access to the data. We deploy the RPI software remotely, making data from all of your wells available almost immediately. Compatibility: The RPI software is available for Cygnet, WinCCU, TDS32, InTouch / InSQL, Universal SCADA Server, and Bristol Open Enterprise. Support eLynx Technologies provides 24x7 Help Desk Support for its customers. eLynx Technologies – [email protected] – www.elynxtech.com