Installation instructions FinKey
Transcription
Installation instructions FinKey
Installation instructions FinKey Content 1 General instructions______________________________________________________________ 2 2 System overview__________________________________________________________________ 2 3 Installation reader unit FinKey SL___________________________________________________ 3 4 Installation reader unit FinKey FS___________________________________________________ 4 5 Installation lock Remote 3000/3010________________________________________________ 5 6 Installation FinKey divider__________________________________________________________ 7 7 Wiring FinKey system_____________________________________________________________ 8 8 Power supply of FinKey system_____________________________________________________ 11 9 Setting the mode of operation_____________________________________________________ 11 10 Setting the signal time “silent alarm”______________________________________________ 11 11 Functional test _________________________________________________________________ 11 12 Technical data_________________________________________________________________ 12 © Carl Wittkopp GmbH - Errors and omissions excepted Installation instructions no 9999-134-0 Installation instructions FinKey 1 General instructions • Please read the installation instructions carefully, before activating the lock. 1.1 Liability notes • The mounting of the electronic lock and the reader unit has to be carried out according to the installation instruction. • We point out that this installation instruction is part of the VdS-certification and non-compliance leads to the loss of this certification. • By opening the lock cover warranty of the manufacturer will be void. • Take care that the reader unit or the lock and the cables are not damaged. 1.2 Installation note • Reader and relay unit are coupled to each other and must not be interchanged with other FinKey systems. 2 System overview 2 FinKey SL FinKey FS Remote 3000 Set 1 Set 3 Set 5 (with alarm signal) Set 9 Set 11 Set 13 (with alarm signal) Remote 3010 Set 2 Set 4 Set 6 (with alarm signal) Set 10 Set 12 Set 14 (with alarm signal) Rel. 1.3 Installation instructions FinKey 3 Installation reader unit FinKey SL 3.1 Reader unit FinKey SL 3.1.1 Dimensions FinKey SL 45 25,8 1,8 3,8 76 60 24 5,8 26 Kabel/Cable 3.2 Mounting 3.2.1 Drill pattern reader unit FinKey SL 45 1 11 3,8 15 Ø1 Opening for cable: drilling min. Drill-hole Ø 11 mm for connection cable has to be drilled into the safe door 76 60 mind. 48 mind. 37 M3 • From the front 2 threaded holes M3 with sufficient depth and 1 through-hole (opening for cable) have to be drilled into the safe door. - up to door strength 25 mm 1 through-hole 48 mm x 37 mm have to be drilled into the safe door. - from door strength 25 mm 1 through-hole Ø 11 mm (opening for cable) have to be drilled into the safe door additionaly. • Fix the input unit with the enclosed countersunk screws M3 from the front. • Affix the cover plate. Rel. 1.3 26 3 Installation instructions FinKey 4 Installation reader unit FinKey FS 4.1 Reader unit FinKey FS 4.1.1 Dimensions FinKey FS Ø 95 49 4.2 Mounting 4.2.1 Drill pattern reader unit FinKey FS Fixing position for screws M4 5,3 41 ±1,5 Possible positions for opening for cable: Ø 11 mm for connection cable has to be drilled into the safe door Fixing position for screws M4/M5 46 ±5 • From the front 2 threaded holes M4/M5 with sufficient depth and 1 through-hole (opening for cable) have to be drilled into the safe door. • Fix the input unit with the respective enclosed cylinder screws M3 from the front. 4 Rel. 1.3 Installation instructions FinKey 5 Installation lock Remote 3000/3010 Before mounting the lock the reader unit has to be installed (see chapter 3 to 6). Wittkopp electronic locks of the Remote series have got standard fixing points and can be mounted in all 4 directions (right-hand, left-hand, up, down) • The lock can be installed in all conventional safes. • Further locking elements can be mounted optionally on the existing holes on the lock’s bolt. Please make sure that the lock and the connections operate properly. • The electronic lock is maintenance free in normal domestic and office surroundings. After approx. 10,000 closures it is recommended to carry out a security and functional test of the electronic lock. • For safety reasons it is not allowed to locate the electronic lock in the area where openings are. • The electronic lock has to be protected against external attacks. • Do not insert any lubricants or other substances into the electronic lock. 5.1 Dimensions lock Remote 3000 5.2 Remote 3010 mechanical emergancy lock If a mechanical emergency lock with VdS class 1 is used, the whole emergency lock system receives VdS class 1. When using a class 2 emergency lock the certification remains the same. 5.2.1 Dimensions lock Remote 3010 - short connection with mechanical emergency lock 66,5 9,1 M4 7 15 41 41 25,4 60,7 7 Ø 13 Hub/Stroke 12 150 Gator 3010 Rel. 1.3 10,6 6,8 66,5 Ø Installation example 25,5 34 + 12 mm Platzbedarf/Required space Mechanical emergency lock 5 Installation instructions FinKey 5.2.2 Dimensions lock Remote 3010 - long connection with mechanical emergency lock 116 88 9,1 Remote 3010 66,5 13,5 34 3 41 60,7 Ø 58,3 (X) Ø7 7 25,4 Installation example 60,7 41 Hub/stroke 12 66,5 88 Area around the unlocking lever must be protected especially. 25 Mechanical emergency lock 5.3 Mounting 5.3.1 Drill pattern lock Remote 3000/3010 66,5 41 17,3 • For fixing the electronic lock 4 threaded holes M6 with depth min. 6 mm (or a comparable inch thread) have to be drilled into the safe door. •_Fixing the electronic lock/emergency lock with screws M6 or a comparable inch thread. Length and material application of the screw has to be selected such as a secure long-term stability is guaranteed. • Turn the screws with a maximum turning force of 3.5 – 5 Nm. •_Independent loosening of the screws has to be avoided. Recommendation: put lock washers underneath the screw’s head. • After the installation the lock’s bolt may not be loaded. • Mind sufficient slackness of the locking point. 66,5 F 41 5.3.2 Bolt load lock Remote17,3 3000/3010 • The maximum and constant bolt load against closing direction may not exceed the following limits: Remote 3000/3010 2,5N 6 Rel. 1.3 Installation instructions FinKey 6 Installation FinKey divider In order to make wiring as easy as possible all components are connected to the FinKey divider. The FinKey divider has to be installed within the secure area. 6.1 Drill pattern FinKey divider 84,5 65,5 65,5 84,5 6.2 Perparing the FinKey divider for wiring Include cable ties for strain-relief and tie the cables Create break through for DC plug Create break-throughs Lead cables into the divider from below Rel. 1.3 7 Installation instructions FinKey 7 Wiring FinKey system Fix the circuit board in the Finkey divider only after the cables have been fixed. Please make sure that the cables are protected from tampering from the outside. Fix the cables within the safe to make sure they can’t be pulled out. 7.1 Terminal assignment lock Remote 3000/3010 Connecting terminal min. 10 mm stripping length Terminal 1 Using the supplied cable 051-1034-00-0 for connecting the FinKey divide and the lock the following colour assignment is shown below: Terminal 1: brown Terminal 2: white Terminal 3: yellow Terminal 4: green +12V 9-12VDC 7.1.1 General assignment plan for the terminal lock Remote 3000/3010 NO X101 1 2 3 4 5 6 7 8 9 10 power supply GND open/close secure / not secure blocking n.c. RIACON-AST072-10 DH2CC6PA NC GND Vcc COM S1 not secure 26.07.2011 09:16:53 f=2.00 C:\Users\naumann.WITTKOPP\Documents\01 Produkte-Einzelprojekte\03 Elostar Remote\02 Bedienungsanleitungen\Anschlussbelegung.sch (Sheet: 1/ • The blocking input allows to inhibit lock openings. Closing or accordingly extending the bolt, is still possible. • The lock electronically checks at the beginning of every opening cycle, whether a blocking signal is active. To combine multiple locks like a double door system, only one common signal line is necessary (easier cabling). • The condition „secure“, when the bolt is in closed position and retained, is signalized by switching contacts directly connected to the terminal block (dry-contact). 8 Rel. 1.3 Installation instructions FinKey 7.2 FinKey divider to reader unit Marking Please note the marking on the connector plug when connecting the cables. In order to pull the cable of the reader units through the drilling, disconnect the cable on its coupler between the reader and the relay unit. • After the installation connect the coupler again. 7.3 FinKey divider to reader unit/lock Connect 4-pin plug from reader unit to plug “reader” Connect 4-pin plug from lock cable to “lock” • Connect the skinner from the FinKey divider to the terminal of the lock and check the adjustment. • Ensure sufficient strain-relief • _In order to loosen single skinners push in the corresponding levers (orange) with an appropriate tool • Keep cable away from sharp edges and moving boltwork components and fix them permanently Rel. 1.3 9 Installation instructions FinKey 7.4 FinKey divider with alarm signal (optional) Connect 2-pin plug from reader unit to plug “Rel” Resistor for signal loop “alarm” Solder jumper for signal loop “alarm” Screw plug “alarm” (2-pin) for connection of alarm signal to burglar alarm system Solder the resistors for signal loops only if the connection will be lead out, link the solder jumper. 7.4.1 FinKey divider with tamper contact (optional) Resistor for signal loop “lid lifted” Solder jumper for “lid lifted” Screw pin “cover” (2-pin) for connection tamper signal with burglar alarm system Solder the resistor of the tamper signal only when the connection should be lead out, link the solder jumper. 10 Rel. 1.3 Installation instructions FinKey 8 Power supply of FinKey system Plug “power supply” Create power supply by plugging in the plug. Lead the cables for “alarm signal” and tamper signal” underneath the plug. 9 Setting the mode of operation The system can be operated in two modes. • Automatic locking: the bolt closes automatically after a set time • Closing with finger: the bolt closes only after a finger was recognized by the reader unit The modes of operation are set via the remote control 9.1 Setting the mode of operation “Automatic locking” The time in which the lock closes automatically is set in seconds. Times possible to set are 5 to 65 seconds (factory setting: 5 seconds). • Press the button RT –R1 on the remote control – opening time (5….65) – OK 9.2 Setting the mode of operation “closing with finger” • Press the buttons RT – R1 on the remote control – 1 – OK 10 Setting the signal time “silent alarm” The signal time of the “silent alarm” is set in seconds. Times possible to set are 5 to 65 seconds (factory setting: 5 seconds). • Press the buttons RT – R2 on the remote control – opening time in seconds (1….65) – OK 11 Functional test • Carry out a functional test after installing the lock (when the door is open). • Trigger the control signal. Press the button 0 – OK on the remote control This function is only possible in factory setting when all three LEDs (green, red and blue) are lit, when no finger is saved yet. • The lock bolt moves in automatically (has to happen easily). The lock is opened. • After triggering another control signal (pulse mode) or after switching off the control signal (hold mode) the lock bolt moves out automatically and locks. The lock is closed. • Keep enough clearance to the locking point. Rel. 1.3 11 Installation instructions FinKey 12 Technical data Dimensions lock (mm) 88 x 60.7 x 34 Material zinc plated steel sheet Ingress protection IP30 Temperature (°C) 5-40 Rel. humidity (%) 10-75 % not condensating Operation conditions (standby *1) supply voltage 12VDC, only power supply without any control contacts (load *2) 7.5 N bold force, supply voltage 12VDC (bold blocked *3) supply voltage 12VDC Voltage (Vcc) 9-12 VDC +/- 10% Current consumption (standby *1) (load *2) (max. *3) typ. 1 µA < 300 mA < 700 mA Power supply Current consumption control inputs - Open/close (mA) - Blocking (mA) < 0.5 mA < 0.1 mA Voltage levels control inputs - Open/close - Blocking (always with reference to ground) 5V – 12 V (max. Vcc) 0-5 V Output - „Secured“ 5-500mA@30V (data sheet Cherry DH) Terminal block wire gauge 0.13 – 0.5 mm² respectively AWG 26-20 12 Rel. 1.3