FinKey - Carl Wittkopp
Transcription
FinKey - Carl Wittkopp
Installation Instructions FinKey FinKey www.cawi.com FinKey Installation Instructions Notes The FinKey system is to be installed exclusively in accordance with the present Installation instructions. We point out that these Installation instructions are an element in the certification of the lock by the VdS. Failure to observe these instructions will invalidate both that certification and any guarantee entitlements. • Modifications to the FinKey system can cause malfunctions. Never make any changes to the system. • The key-operated lock is to be secured with four M6 steel screws and the corresponding lock washers. The fastening screws may be tightened down to maximum torque of 10 Nm. • The locking bolt must move easily when positioned for installation. It may not be subjected to, tension or pressure. • The breakout segment in the back of the lock case may not be concealed by any other components. • No lubricants or other materials may be permitted to enter the fingertip scanner, junction box or lock. • The key must not be canted when it is inserted into the lock; never apply force. Be sure to observe this when installing and adjusting the lock on the door of the cabinet. • The FinKey system may be opened only by the manufacturer or by persons authorized by the manufacturer to do so. • We recommend having the FinKey system installed only by authorized personnel as the safe’s certification could otherwise be invalidated. • The safe may be used only indoors. E&O; subject to technical modification without prior notice 2 Rel. 1 of 01.07.2009 Installation Instructions No. 9999-082-0 E7510_E.indd FinKey Installation Instructions Included components 1 pc. Right hand lock Item-no. 2688 2 pcs. Key (die cast zinc) 65 mm or 95 mm 4 pcs. Cheese-head screw, M6 x 30 Lock washer, A 6.4 1 pc. Protective tubing 1 pc. Fingertip scanner 2 pcs. Grommet 2 each. Hex nut, M4 Washer, 4.3, steel Cheese-head screw, M4x20 2 pcs. Terminating fixture 2 each Cheese-head sheet metal screw 3.9 x 13, steel 4 pcs. Recessed sheet metal screw 3.5x19, steel 1 pc. Junction box 1 pc. Connector cable 2 pcs. Adhesive pad 1 pc. Wall transformer 3 pcs. Self-adhesive base 1 pc. Instruction Manual 3 pcs. Cable tie Installation Instructions No. 9999-082-0 E7510_E.indd Rel. 1 of 01.07.2009 3 FinKey Installation Instructions Mounting the fingertip scanner (Figs. 1 – 4) Recommended: Empfehlun1300 g 1300 1 See drilling template for fingertip scanner on page 11 2 4 Rel. 1 of 01.07.2009 Installation Instructions No. 9999-082-0 E7510_E.indd FinKey Installation Instructions 3 11-Yellow gelb 22-Green grün 3White 3- weiß 44-Brown braun 4 Installation Instructions No. 9999-082-0 E7510_E.indd Rel. 1 of 01.07.2009 5 FinKey Installation Instructions Mounting the lock item-no. 2688 5 Power supply: input 12V, minimum 100 mA 4 x M6 x30 max. 10 Nm Mounting the junction box (Figs. 6 – 13) 6 6 Rel. 1 of 01.07.2009 Installation Instructions No. 9999-082-0 E7510_E.indd FinKey Installation Instructions 7 See drilling template for the terminating fixture on page 11. 8 Installation Instructions No. 9999-082-0 E7510_E.indd Lay the cable from the wall transformer to the junction box. Use cable ties to secure the cables to the self-adhesive bases. Rel. 1 of 01.07.2009 7 FinKey Installation Instructions 9 3 2 1 Yellow gelb Green grün White weiß braun Brown 4 Anschluss Scanner Scanner connection 4 6 Lock Anschluss connection Schloss 7 8 Power Anschluss connection (polarity variable) Strom Cable connection 10 8 Rel. 1 of 01.07.2009 Installation Instructions No. 9999-082-0 E7510_E.indd FinKey Installation Instructions Putting into service / Factory setting (Figs. 11 – 14) 11 Red and blue slide switch Before putting the FinKey into service, an unequivocal connection will have to be made between the fingertip scanner and the junction box. To make this connection, actuate the red and blue slide switch inside the junction box. Wait for 60 seconds and then return the slide switch to its original position. 12 Yellow / red / green LEDs light continuously Installation Instructions No. 9999-082-0 E7510_E.indd Rel. 1 of 01.07.2009 9 FinKey Installation Instructions 13 IMPORTANT! Reset the fingertip scanner to the factory setting before closing the cabinet door (see page 3 of the instruction manual). It might otherwise be impossible to open the cabinet. 14 10 Putting into service / Factory setting restored Rel. 1 of 01.07.2009 Installation Instructions No. 9999-082-0 E7510_E.indd Installation Instructions FinKey Bohrplan Fingerscanner M1:1 Drilling templates Drilling template for fingertip scanner 1:1 scale 4, 2 4 50 Bohrplan Endstück M1:1 Bohrplan Endstück M1:1 ø4,2 für Schraube / /Mutter 4.2 mm diam. for bolt nut ø3,3 für M4 Gewinde 3.3 mm diam. for M4 threads ø3,2 für Blechschraube 3.2 mm diam. for sheet metal screw 5 5 Drilling template for terminating fixture1:1 scale Installation Instructions No. 9999-082-0 E7510_E.indd 20 Rel. 1 of 01.07.2009 11 20 3,3 10 10 3,3 More than 150 years of tradition and innovation in the production of high-security locks Carl Wittkopp GmbH Sternbergstraße 5 D-42551 Velbert, Germany Phone +49 (0) 2051 9566-0 Fax +49 (0) 2051 9566-66 [email protected] www.cawi.com