FinKey - Carl Wittkopp

Transcription

FinKey - Carl Wittkopp
Installation Instructions
FinKey
FinKey
www.cawi.com
FinKey
Installation Instructions
Notes
The FinKey system is to be installed exclusively in accordance with
the present Installation instructions.
We point out that these Installation instructions are an element in
the certification of the lock by the VdS. Failure to observe these
instructions will invalidate both that certification and any guarantee entitlements.
• Modifications to the FinKey system can cause malfunctions. Never make any changes to the system.
• The key-operated lock is to be secured with four M6 steel screws
and the corresponding lock washers. The fastening screws may
be tightened down to maximum torque of 10 Nm.
• The locking bolt must move easily when positioned for installation. It may not be subjected to, tension or pressure.
• The breakout segment in the back of the lock case may not be
concealed by any other components.
• No lubricants or other materials may be permitted to enter the
fingertip scanner, junction box or lock.
• The key must not be canted when it is inserted into the lock; never apply force. Be sure to observe this when installing and adjusting the lock on the door of the cabinet.
• The FinKey system may be opened only by the manufacturer or
by persons authorized by the manufacturer to do so.
• We recommend having the FinKey system installed only by
authorized personnel as the safe’s certification could otherwise
be invalidated.
• The safe may be used only indoors.
E&O; subject to technical modification without prior notice
2
Rel. 1 of 01.07.2009
Installation Instructions No. 9999-082-0
E7510_E.indd
FinKey
Installation Instructions
Included components
1 pc.
Right hand lock
Item-no. 2688
2 pcs.
Key (die cast zinc)
65 mm or 95 mm
4 pcs.
Cheese-head screw,
M6 x 30
Lock washer, A 6.4
1 pc.
Protective tubing
1 pc.
Fingertip scanner
2 pcs.
Grommet
2 each.
Hex nut, M4
Washer, 4.3, steel
Cheese-head screw,
M4x20
2 pcs.
Terminating fixture
2 each
Cheese-head sheet
metal screw
3.9 x 13, steel
4 pcs.
Recessed sheet metal
screw 3.5x19, steel
1 pc.
Junction box
1 pc.
Connector cable
2 pcs.
Adhesive pad
1 pc.
Wall transformer
3 pcs.
Self-adhesive base

1 pc.
Instruction Manual
3 pcs.
Cable tie
Installation Instructions No. 9999-082-0
E7510_E.indd
Rel. 1 of 01.07.2009
3
FinKey
Installation Instructions
Mounting the fingertip scanner (Figs. 1 – 4)
Recommended:
Empfehlun1300
g 1300
1
See drilling template
for fingertip scanner
on page 11
2
4
Rel. 1 of 01.07.2009
Installation Instructions No. 9999-082-0
E7510_E.indd
FinKey
Installation Instructions
3
11-Yellow
gelb
22-Green
grün
3White
3- weiß
44-Brown
braun
4
Installation Instructions No. 9999-082-0
E7510_E.indd
Rel. 1 of 01.07.2009
5
FinKey
Installation Instructions
Mounting the lock item-no. 2688
5
Power supply:
input 12V,
minimum 100 mA
4 x M6 x30
max. 10 Nm
Mounting the junction box (Figs. 6 – 13)
6
6
Rel. 1 of 01.07.2009
Installation Instructions No. 9999-082-0
E7510_E.indd
FinKey
Installation Instructions
7
See drilling template
for the terminating
fixture on page 11.
8
Installation Instructions No. 9999-082-0
E7510_E.indd
Lay the cable from the wall
transformer to the junction
box. Use cable ties to secure
the cables to the
self-adhesive bases.
Rel. 1 of 01.07.2009
7
FinKey
Installation Instructions
9
3 2
1
Yellow
gelb
Green
grün
White
weiß
braun
Brown
4
Anschluss
Scanner
Scanner
connection
4 6
Lock
Anschluss
connection
Schloss
7 8
Power
Anschluss
connection
(polarity variable)
Strom
Cable connection
10
8
Rel. 1 of 01.07.2009
Installation Instructions No. 9999-082-0
E7510_E.indd
FinKey
Installation Instructions
Putting into service / Factory setting (Figs. 11 – 14)
11
Red and blue slide switch
Before putting the FinKey into service, an unequivocal connection
will have to be made between the fingertip scanner and the junction box. To make this connection, actuate the red and blue slide
switch inside the junction box. Wait for 60 seconds and then return
the slide switch to its original position.
12
Yellow / red / green LEDs
light continuously
Installation Instructions No. 9999-082-0
E7510_E.indd
Rel. 1 of 01.07.2009
9
FinKey
Installation Instructions
13
IMPORTANT! Reset the fingertip scanner to the factory setting
before closing the cabinet door (see page 3 of the instruction
manual).
It might otherwise be impossible to open the cabinet.
14
10
Putting into service /
Factory setting restored
Rel. 1 of 01.07.2009
Installation Instructions No. 9999-082-0
E7510_E.indd
Installation Instructions
FinKey


Bohrplan Fingerscanner M1:1
Drilling templates
Drilling template for fingertip scanner 1:1 scale
4,
2
4
50

Bohrplan Endstück M1:1 Bohrplan Endstück M1:1

ø4,2
für Schraube
/ /Mutter
4.2 mm
diam. for bolt
nut
ø3,3
für M4
Gewinde
3.3 mm
diam.
for M4 threads
ø3,2
für Blechschraube
3.2 mm
diam. for sheet metal screw


5
5
Drilling template for terminating fixture1:1 scale
Installation Instructions No. 9999-082-0
E7510_E.indd
20
Rel. 1 of 01.07.2009
11


20
3,3
10
10
3,3
More than
150 years of
tradition and innovation
in the production of
high-security locks
Carl Wittkopp GmbH
Sternbergstraße 5
D-42551 Velbert, Germany
Phone +49 (0) 2051 9566-0
Fax
+49 (0) 2051 9566-66
[email protected]