download/view spec sheet
Transcription
download/view spec sheet
Enclosure Options Locking Front Doors Offered in lightly smoked plexi, 25% open area perf, 64% open area perf, plexi-vented and solid configurations. Beveled corners provide a stylish modern appearance while hinging either left or right. Black textured powder coat finish. Includes keylock. FD LVFD PFD PVFD VFD Enclosure Options Front Door Part # (Fits MRK, VRK, VMRK, WRK, ERK, DWR, SR Series) Solid Plexi 25% Open Area Perf 64% Open Area Perf Plexi Vented # of Rackspaces FD-54 PFD-54 VFD-54 - - 54 FD-46 PFD-46 VFD-46 LVFD-46 - 46 FD-45 PFD-45 VFD-45 LVFD-45 - 45 FD-44 PFD-44 VFD-44 LVFD-44 PVFD-44 44 FD-42 PFD-42 VFD-42 LVFD-42 - 42 FD-40 PFD-40 VFD-40 LVFD-40 - 40 FD-37 PFD-37 VFD-37 LVFD-37 - 37 FD-35 PFD-35 VFD-35 LVFD-35 - 35 FD-27 PFD-27 VFD-27 - - 27 FD-24 PFD-24 VFD-24 LVFD-24 - 24 FD-21 PFD-21 VFD-21 LVFD-21 - 21 FD-18 PFD-18 VFD-18 LVFD-18 - 18 FD-16 PFD-16 VFD-16 LVFD-16 - 16 FD-12 PFD-12 VFD-12 LVFD-12 - 12 FD-10 PFD-10 VFD-10 LVFD-10 - 10 FD-8 PFD-8 VFD-8 - - 8 Front Door Part # (Fits DRK Series) DVFD-44 25% Open Area Plexi Plexi Vented # of Rackspaces DVFD-44 DPFD-44 DPVFD-44 44 DPVFD-44 Vent Blockers VBK Series Vent Blockers are used to promote active thermal management. Designed to prevent the re-circulation of hot air between top-mount fans and nearby vent openings, Vent Blockers should be placed over the enclosure’s vents located on the upper front of the enclosure, upper sides, and upper rear door (depending on enclosure). This will ensure that heated enclosure air will be forced out through the top-mounted exhaust fans instead of re-circulating, keeping equipment cool. vent blockers magnetized on one side only to eliminate stray magnetic fields Vent Blockers mount to the inside of enclosures to direct airflow Part # Used On Part # Used On VBK-W27-W32 WRK-xx27 & WRK-xx-32 VBK-SD22 SR-40-22, DWR-xx-22 VBK-WSA27 WRK-xxSA-27 VBK-S28 SR-xx-28 VBK-WSA32 WRK-xxSA-32, WR-xx-32* VBK-S32 SR-xx-32, DWR-xx-32 VBK-E20 ERK-xx20, DWR-xx-26 VBK-S42 WR-xx-42* VBK-E25 ERK-xx25 VBK-V VRK Series VBK-SCRK27 SCRK Series VBK-DRK DRK Series VBK-D17 DWR-xx-17 * When WR is not flush against a wall, block the rear opening with the optional rear access panel, model #WR-RAP-xx BGR and EGR options are shown on rack series pgs. 34 middleatlantic.com • V: 800-266-7225 • F: 800-392-3955 Enclosure Options Thermal Management Kits for Rear Door Middle Atlantic Products standard solid rear doors on WRK, MRK and ERK Series enclosures are configurable for achieving optimal active or passive thermal management. Fan, vent and filter kits are available to install after laser knockouts are removed. Fan and vent kits now available for solid split rear doors. KO-AWFP2 KO-VT3 fan panel kit laser knockouts standard KO-FILTER3 WRK, MRK, ERK Standard Solid Rear Doors hot air out Solid Split Rear Doors Part # Description Part # Description KO-AWFP2 fan kit with two fans, 190 CFM KO-CRD-FAN KO-VT3 vent panel kit fan kit with two fans, 190 CFM and two vents KO-FILTER3 filter kit KO-CRD-VT filter kit KO-WSB3 blank panel kit vent panel kit cool air in Optional Doors Rear Door Part # (Fits WMRK, MRK, VRK, VMRK, WRK Series) Top & Bottom Slot Vented 79% Open Area Split Perf 64% Open Area Perf Solid Split Fits ERK Only Top & Bottom Slot Vented # of Rackspaces - MW-CLVRD-45 - MW-CRD-45 - 45 MW-VRD-44 MW-CLVRD-44 MW-LVRD-44 MW-CRD-44 ERK-VRD-44 44 - MW-CLVRD-42 - MW-CRD-42 - 42 - - MW-LVRD-40 - ERK-VRD-40 40 - - - - ERK-VRD-35 35 - - - - ERK-VRD-27 27 - MW-CLVRD-24 - MW-CRD-24 - - - - ERK-VRD-21 21 - - - - ERK-VRD-18 18 Enclosure Options Substitute a vented rear door for a solid rear door in selected sizes. Black textured powder coat finish. See web for racks available ‘less rear door’ (LRD). Fully vented rear doors have 64% open area. Split rear doors with 3 point latch offer 79% open area and require less floor space when accessing rear equipment connections. 24 Rear Door Part # (Fits DRK Series) Slot Vents Fully Vented Top & Bottom Slot Vented 64% Open Area Perf 79% Open Area Split Perf Solid Split DFVRD-44 DVRD-44 DSVRD-44 DCLVRD-44 DCRD-44 n-ASTER#ATALOGsEXCEPTIONAL SUPPORT & PROTECTION™ 35 High CFM Configurable Rear Doors Removes hot air from densely populated server enclosures. Spec. # 96-01093 A&E for full product info. NEW! Great solution when top mounted fans are not enough to move the required CFM. Structural Features s )DEALFORHOTAISLECOLDAISLEAPPLICATIONSWHEREAIRRETURNISABOVEHOTAISLEBECAUSE EXHAUSTAIRISDIRECTEDUPWARDTOWARDAIRRETURNS s %XCELLENTWHENENCLOSUREISHIGHLYPOPULATEDWITH.62S$62SORSERVERSTHATAREFRONT INTAKEREAREXHAUSTTYPE s &INISHEDINADURABLEBLACKTEXTUREDPOWDERCOAT Thermal Management s 0RECONlGUREDWITHSIXvFANS4HESEFANSHAVEADJUSTABLELOCATIONSANDCANBEARRANGED WHERETHEYAREMOSTNEEDED s !DDITIONALFANSCANBEADDEDTOINCREASETOTAL#&-$OORSCANACCEPTUPTOTOTALFANS TOBOOSTTOTALAIRMOVEMENTUPTO#&-FORMAXIMUMCOOLING s !HIGHCAPACITYTHERMOSTATICFANCONTROLLERISAVAILABLEnSEEBELOW Cable Management s %ACHDOORHASAREMOVABLEv3IGNAL3AFE™)%#CORDTOALLOWFORDOORSTOBEPLUGGEDINTO SEPARATECIRCUITS3HORTER)%#CORDSCANBESUBSTITUTEDFORIMPROVEDCABLEMANAGEMENT &ORMOREON3IGNAL3AFE TECHNOLOGYSEEPG High CFM Configurable Rear Doors Regulatory / Certifications s '2%%.'5!2$)NDOOR!IR1UALITY#ERTIlEDFOR#HILDRENAND3CHOOLSTHEMOSTSTRICTLEVEL s 5,,ISTEDINTHE53AND#ANADA Part # Description Fits -7#&2$ SPACESPLITFANREARDOOR Additional 1/2 Free Air Blank Panels (Qty. of 4) CFM -7#&2$0., -7#&2$ SPACESPLITFANREARDOOR -2+72+62+ -7#&2$0., -7#&2$ SPACESPLITFANREARDOOR WMRK -7#&2$0., DRK $#&2$0., $#&2$ SPACESPLITFANREARDOOR WMRK -7#&2$&+)4 ADDITIONALvFANFOR-7#&2$AND$#&2$ High CFM Split Rear Door 3UPPLY $UCT adjustable fan panels (8 per half door) shorter IEC cords can be used to simplify cable management FANCONTROLLERRACKSPACE FC-CFRD MW-CFRD-XX High CFM Split Rear Door 2ETURN !IR$UCT 2ETURN $UCT MW-CFRD-XX &RONT 2AISED &LOOR4ILES 6ENT 'RATE 3IDE6IEW 3IDE6IEW 0ROPER!IR#ONDITIONING !IRmOWAND2ACK0LACEMENT MW-CFRD-1/2PNL-45 HALFHEIGHTBLANKPANEL 0ROPER&ORCED!IRON2AISED&LOOR 6ENTED&LOOR'RATE0LACEMENT Heavy-Duty Fan Thermostatic Controller for High CFM Rear Doors s s s s s /NEUNITCANPOWERUPTOFANSINAFULLYPOPULATEDSYSTEM /NERACKSPACEMOUNTSATTOPORBOTTOMWITHmEXIBLEMOUNTINGEARS 3ETTINGFORTHERMOSTATICTEMPERATURECONTROL 3ETTINGFORPROPORTIONALORSNAPACTION %4,,ISTEDINTHE53AND#ANADA Part # FC-CFRD 36 MIDDLEATLANTICCOMs6s& FC-CFRD