download/view spec sheet

Transcription

download/view spec sheet
Enclosure Options
Locking Front Doors
Offered in lightly smoked plexi, 25% open area perf, 64% open area perf, plexi-vented and solid configurations. Beveled corners provide a
stylish modern appearance while hinging either left or right. Black textured powder coat finish. Includes keylock.
FD
LVFD
PFD
PVFD
VFD
Enclosure Options
Front Door Part # (Fits MRK, VRK, VMRK, WRK, ERK, DWR, SR Series)
Solid
Plexi
25% Open Area Perf
64% Open Area Perf
Plexi Vented
# of Rackspaces
FD-54
PFD-54
VFD-54
-
-
54
FD-46
PFD-46
VFD-46
LVFD-46
-
46
FD-45
PFD-45
VFD-45
LVFD-45
-
45
FD-44
PFD-44
VFD-44
LVFD-44
PVFD-44
44
FD-42
PFD-42
VFD-42
LVFD-42
-
42
FD-40
PFD-40
VFD-40
LVFD-40
-
40
FD-37
PFD-37
VFD-37
LVFD-37
-
37
FD-35
PFD-35
VFD-35
LVFD-35
-
35
FD-27
PFD-27
VFD-27
-
-
27
FD-24
PFD-24
VFD-24
LVFD-24
-
24
FD-21
PFD-21
VFD-21
LVFD-21
-
21
FD-18
PFD-18
VFD-18
LVFD-18
-
18
FD-16
PFD-16
VFD-16
LVFD-16
-
16
FD-12
PFD-12
VFD-12
LVFD-12
-
12
FD-10
PFD-10
VFD-10
LVFD-10
-
10
FD-8
PFD-8
VFD-8
-
-
8
Front Door Part # (Fits DRK Series)
DVFD-44
25% Open Area
Plexi
Plexi Vented
# of Rackspaces
DVFD-44
DPFD-44
DPVFD-44
44
DPVFD-44
Vent Blockers
VBK Series Vent Blockers are used to promote active thermal management.
Designed to prevent the re-circulation of hot air between top-mount fans and nearby
vent openings, Vent Blockers should be placed over the enclosure’s vents located on
the upper front of the enclosure, upper sides, and upper rear door (depending on
enclosure). This will ensure that heated enclosure air will be forced out through the
top-mounted exhaust fans instead of re-circulating, keeping equipment cool.
vent blockers magnetized on one side only to eliminate
stray magnetic fields
Vent Blockers
mount to the inside
of enclosures to
direct airflow
Part #
Used On
Part #
Used On
VBK-W27-W32
WRK-xx27 & WRK-xx-32
VBK-SD22
SR-40-22, DWR-xx-22
VBK-WSA27
WRK-xxSA-27
VBK-S28
SR-xx-28
VBK-WSA32
WRK-xxSA-32, WR-xx-32*
VBK-S32
SR-xx-32, DWR-xx-32
VBK-E20
ERK-xx20, DWR-xx-26
VBK-S42
WR-xx-42*
VBK-E25
ERK-xx25
VBK-V
VRK Series
VBK-SCRK27
SCRK Series
VBK-DRK
DRK Series
VBK-D17
DWR-xx-17
* When WR is not flush against a wall, block
the rear opening with the optional rear
access panel, model #WR-RAP-xx
BGR and EGR options are shown on rack series pgs.
34
middleatlantic.com • V: 800-266-7225 • F: 800-392-3955
Enclosure Options
Thermal Management Kits for Rear Door
Middle Atlantic Products standard solid rear doors on WRK, MRK and ERK Series enclosures are
configurable for achieving optimal active or passive thermal management. Fan, vent and filter kits
are available to install after laser knockouts are removed. Fan and vent kits now available for solid
split rear doors.
KO-AWFP2
KO-VT3
fan
panel kit
laser knockouts
standard
KO-FILTER3
WRK, MRK, ERK Standard Solid Rear Doors
hot air out
Solid Split Rear Doors
Part #
Description
Part #
Description
KO-AWFP2
fan kit with two fans, 190 CFM
KO-CRD-FAN
KO-VT3
vent panel kit
fan kit with two fans, 190 CFM and
two vents
KO-FILTER3
filter kit
KO-CRD-VT
filter kit
KO-WSB3
blank panel kit
vent
panel kit
cool air in
Optional Doors
Rear Door Part # (Fits WMRK, MRK, VRK, VMRK, WRK Series)
Top & Bottom Slot Vented
79% Open Area Split Perf
64% Open Area Perf
Solid Split
Fits ERK Only
Top & Bottom Slot Vented
# of Rackspaces
-
MW-CLVRD-45
-
MW-CRD-45
-
45
MW-VRD-44
MW-CLVRD-44
MW-LVRD-44
MW-CRD-44
ERK-VRD-44
44
-
MW-CLVRD-42
-
MW-CRD-42
-
42
-
-
MW-LVRD-40
-
ERK-VRD-40
40
-
-
-
-
ERK-VRD-35
35
-
-
-
-
ERK-VRD-27
27
-
MW-CLVRD-24
-
MW-CRD-24
-
-
-
-
ERK-VRD-21
21
-
-
-
-
ERK-VRD-18
18
Enclosure Options
Substitute a vented rear door for a solid rear door in selected sizes. Black textured powder coat finish. See web for racks available ‘less rear
door’ (LRD). Fully vented rear doors have 64% open area. Split rear doors with 3 point latch offer 79% open area and require less floor space when
accessing rear equipment connections.
24
Rear Door Part # (Fits DRK Series)
Slot Vents Fully Vented
Top & Bottom Slot Vented
64% Open Area Perf
79% Open Area Split Perf
Solid Split
DFVRD-44
DVRD-44
DSVRD-44
DCLVRD-44
DCRD-44
n-ASTER#ATALOGsEXCEPTIONAL SUPPORT & PROTECTION™
35
High CFM Configurable Rear Doors
Removes hot air from densely populated server enclosures.
Spec. #
96-01093
A&E
for full
product
info.
NEW!
Great solution when top mounted fans are not enough to move the required CFM.
Structural Features
s )DEALFORHOTAISLECOLDAISLEAPPLICATIONSWHEREAIRRETURNISABOVEHOTAISLEBECAUSE
EXHAUSTAIRISDIRECTEDUPWARDTOWARDAIRRETURNS
s %XCELLENTWHENENCLOSUREISHIGHLYPOPULATEDWITH.62S$62SORSERVERSTHATAREFRONT
INTAKEREAREXHAUSTTYPE
s &INISHEDINADURABLEBLACKTEXTUREDPOWDERCOAT
Thermal Management
s 0RECONlGUREDWITHSIXvFANS4HESEFANSHAVEADJUSTABLELOCATIONSANDCANBEARRANGED
WHERETHEYAREMOSTNEEDED
s !DDITIONALFANSCANBEADDEDTOINCREASETOTAL#&-$OORSCANACCEPTUPTOTOTALFANS
TOBOOSTTOTALAIRMOVEMENTUPTO#&-FORMAXIMUMCOOLING
s !HIGHCAPACITYTHERMOSTATICFANCONTROLLERISAVAILABLEnSEEBELOW
Cable Management
s %ACHDOORHASAREMOVABLEv3IGNAL3AFE™)%#CORDTOALLOWFORDOORSTOBEPLUGGEDINTO
SEPARATECIRCUITS3HORTER)%#CORDSCANBESUBSTITUTEDFORIMPROVEDCABLEMANAGEMENT
&ORMOREON3IGNAL3AFE TECHNOLOGYSEEPG
High CFM Configurable Rear Doors
Regulatory / Certifications
s '2%%.'5!2$)NDOOR!IR1UALITY#ERTIlEDFOR#HILDRENAND3CHOOLSTHEMOSTSTRICTLEVEL
s 5,,ISTEDINTHE53AND#ANADA
Part #
Description
Fits
-7#&2$ SPACESPLITFANREARDOOR
Additional 1/2
Free Air
Blank Panels (Qty. of 4)
CFM
-7#&2$0.,
-7#&2$ SPACESPLITFANREARDOOR -2+72+62+
-7#&2$0.,
-7#&2$ SPACESPLITFANREARDOOR
WMRK
-7#&2$0.,
DRK
$#&2$0.,
$#&2$
SPACESPLITFANREARDOOR
WMRK
-7#&2$&+)4 ADDITIONALvFANFOR-7#&2$AND$#&2$
High CFM Split Rear Door
3UPPLY
$UCT
adjustable fan panels
(8 per half door)
shorter IEC cords can be used to
simplify cable management
FANCONTROLLERRACKSPACE
FC-CFRD
MW-CFRD-XX
High CFM Split Rear Door
2ETURN
!IR$UCT
2ETURN
$UCT
MW-CFRD-XX
&RONT
2AISED
&LOOR4ILES
6ENT
'RATE
3IDE6IEW
3IDE6IEW
0ROPER!IR#ONDITIONING
!IRmOWAND2ACK0LACEMENT
MW-CFRD-1/2PNL-45
HALFHEIGHTBLANKPANEL
0ROPER&ORCED!IRON2AISED&LOOR
6ENTED&LOOR'RATE0LACEMENT
Heavy-Duty Fan Thermostatic Controller for High CFM Rear Doors
s
s
s
s
s
/NEUNITCANPOWERUPTOFANSINAFULLYPOPULATEDSYSTEM
/NERACKSPACEMOUNTSATTOPORBOTTOMWITHmEXIBLEMOUNTINGEARS
3ETTINGFORTHERMOSTATICTEMPERATURECONTROL
3ETTINGFORPROPORTIONALORSNAPACTION
%4,,ISTEDINTHE53AND#ANADA
Part #
FC-CFRD
36
MIDDLEATLANTICCOMs6s&
FC-CFRD