SAIA Switch Catalog - Contact Evolution SA

Transcription

SAIA Switch Catalog - Contact Evolution SA
The data used in this Product Overview may be used as a guideline
only. Specific operational characteristics of our products may vary
according to individual applications. It is strongly recommended that
specific operating conditions are clarified with Johnson Electric before
application.
Johnson Electric Terms and Conditions of Sale apply.
All data may be subject to change without notice.
Table of Contents
Johnson Electric Group
Thermoplastic ­Microswitches
Overview
2
How we are organized3
4
Looking for a specialized switching solution?
Saia is a leading global brand for switches for the ­
appliances and consumer products industries Subminiature
X420
Sealed Microswitches
Subminiature
V4NS25
V4NCS
5
Switches for Locking Mechanisms5
Switches in the Circuit Breaker Industry6
Switches for domestic appliances6
29
Thermoset plastic Microswitches
Miniature
XG34
Thermoplastic Microswitches
Miniature
X339
Terminology: Snap-action switches7
Snap-action Microswitches14
Miniature
Thermoset plastic
Subminiature
Saia microswitches
3 mm contact gap Microswitch
XC15
34044
47
Table of preferred products
[email protected]
www.saia-switch.com
1
Overview
The Johnson Electric Group is one of the world’s largest providers of motion
subsystems and motion components for automotive, medical and industrial
applications.
Over the years, we have shipped billions of motors to more than thirty
countries in over one hundred different applications. Johnson Electric
has an annual production capacity of one billion motors and motion
subsystems.
Johnson Electric is the most reliable partner
Johnson Electric is responsive and flexible; and has
the financial stability and organizational integrity to
meet all of our commitments and to support our
customers’ success. Product reliability and assurance
At the heart of Johnson Electric’s success is our
commitment to make our customers successful.
Our customers include many of the world’s leading
industrial, consumer and automotive companies. We
begin by understanding our customers’ business
needs, and the product application requirements of
the end user of our customers’ products. Then we
design and deliver innovative motion solutions that
help our customers to differentiate their products in
the marketplace. Our goal is to be instrumental in
the successful launch of our customers’ products in
their respective marketplaces.
of supply are our commitment.
Johnson Electric is «The Safe
Choice»
■
■
Unmatched assurance of supply.
■
Rigorous supply chain management and complete
integrity in compliance with standards.
■
Unsurpassed on-time delivery.
■
Global logistics support 24/7.
■
Collaborative design and project management
process.
■
Product life cycle support from creation to
end-of-life.
Our Brand Promise
Johnson Electric delivers
competitive advantage
2
Financial strength and long standing supplier
relationships.
Our business growth hinges with leading «branded»
goods producers to deliver differentiation and
Johnson Electric delivers differentiation and
innovation through our motion products. The core
innovation through its motion products – subsystems
platform for delivering these solutions is a highly
comprising of Stepper Motors, DC Motors, AC
developed production base and focused customer
Motors, Piezo-electric Motors, Switches, Solenoids,
support teams throughout the world. This combines
Flexi Circuits, Motion Control, Precision Plastics and
scale advantages in production and procurement with
Precision Gears.
skilled and dedicated motion application experts.
Saia microswitches
[email protected]
www.saia-switch.com
How we are organized
Johnson Electric Group
Automotive
Products Group
Industry Products
Group
Johnson
Medtech
Components &
Services
Other Group
Businesses
Parlex Corporation
Johnson Electric Trading
Saia-Burgess Controls
Nanomotion
Johnson Electric Capital
China Autoparts, Inc
The Group’s motion systems,
motors and switches businesses are
managed through three operating
divisions: Automotive Products
Group, Industry Products Group and
Johnson Medtech.
primarily in subsystem for medication delivery systems,
surgical robotics and image guided surgery.
Supporting these three business units is the
Components & Services division which produces metal
and plastic parts, tooling and production equipment
for the Group. Johnson Electric is a highly vertically
The Automotive Products Group (APG) is focused
integrated business that manufactures an exceptionally
on providing customized motion solutions for all
wide range of components that form the basis for its
major automotive applications. APG goes to market
final products. We make magnets, bearings, shafts,
under three product brands: Saia-Burgess for custom
housings, laminations, commutators and die cast parts.
actuators; GATE for engine cooling fan modules; and
We also build tools, assembly fixtures, plastic molds
Johnson Motor for DC motors and brushless DC motors.
as well as armature winding and other production
machines.
The Industry Products Group (IPG) provides motion
products and solutions for various commercial
Supporting our customers worldwide are sixteen
and industrial application sectors, including home
R&D centres located in Hong Kong (China), Shenzhen
appliances, power tools, business equipment, personal
(China), Shanghai (China), Nagano (Japan), Yokneam
care products, medical equipment, building automation,
(Israel), Asti (Italy), Murten (Switzerland), Halver
security, audio-visual and other industrial products. IPG
(Germany), Dresden (Germany), Oldenburg (Germany),
goes to market under seven product brands: Johnson
Isle of Wright (Parlex), San Jose (USA), Methuen (USA),
Motor for DC motors, AC motors and BLDC motors;
Vandalia (USA), Springfield (USA) and Plymouth (USA).
Saia Motor for stepper motors and synchronous motors;
Ledex and Dormeyer for solenoids; and Saia, Bär,
The Group also includes a number of complementary
Burgess, th-contact brands for switches.
subsidiary companies. These include an innovative
provider of flexible printed circuits and interconnect
Johnson Medtech is an ISO13485 certified designer and
solutions; a successful niche player in the
manufacturer of motion related products for the medical
programmable controls industry; and a rapidly growing
device industry. The focus of Johnson Medtech is
China auto parts business.
Saia microswitches
[email protected]
www.saia-switch.com
3
Looking for a specialized switching solution?
Look
Look
no no
further:
further.
addition to
wide
range
of standard
products products
shown
InInaddition
tothe
the
wide
range
of standard
shown in Johnson Electric catalogues, we will be
in this catalog, we will be happy to work with you to meet
happy
to
work
with
you
to
meet
your
system
needs.
If your application requires more than a standard
your switching needs. If your application requires more
than a standard
product
solution,
please consider
product
solution,
please
consider
us earlyusinearly
your design process. Our product development team will
your design process. Our product development team
bein
happy
to
discuss
your
specification,
whether
you need a special value-added assembly or a
will be happy to discuss your specification, whether you
complete
system.
specialize
in developing
need a special
switchWe
design
or a complete
value-added solutions for medium and high-volume applications.
assembly. We specialize in developing switches for
demanding industrial environments.
The images shown give some examples of our capabilities.
The images shown give some examples of our
capabilities.
Building Automation
& Security
Subsystems
Value Added Solutions
Home Appliances,
White Goods,
Floor Care
Business Machines,
Leisure & Fitness
Transportation
Industrial Equipment
& Automation
Power & Garden Tools
Healthcare &
Medical Equipment
Burgess Switch Catalog
SAIA Switch Catalog
4
Saia
Saiamicroswitches
microswitches
IPG210/10/E/03
[email protected]
[email protected]
Johnson Electric Group
12 Science Park East Avenue, 6/F
Hong Kong Science Park, Shatin, NT
Hong Kong
Tel:
+852 2663 6688
Fax:
+852 2897 2054
Website: www.johnsonelectric.com
Johnson Electric
Products
Johnson Electric
Johnson Electric Group
12 Science Park East Avenue, 6/F
Hong Kong Science Park, Shatin, NT
Hong Kong
Tel:
+852 2663 6688
Fax:
+852 2897 2054
Website: www.johnsonelectric.com
IPG220/10/E/03
www.saia-switch.com
Saia is a leading global brand for switches for the
­appliances and consumer products industries
Saia defines precision switching for high volumes.
Uncompromising reliability
The Saia brand focuses firmly on miniature and
subminiature snap-action switch types, the world’s
two most commonly used industry standards.
With many UL, CSA and ENEC approvals, the
performance of Saia products is globally recognized.
With tens of millions of switches produced each year,
this reliability is proven and established.
Wide range
Snap-action switches have to fulfill a wide variety of
functions. Whether it is signal or power switching,
high or low force actuation, there will be a Saia switch
for your application – with extensive terminal and lever
options to make your selection straightforward.
Precision actuation
Snap-action switches offer high levels of repeat
accuracy and switch virtually independently of
actuation speed and force. This is the mechanism of
choice for pressure sensing, timing and position
indicating applications.
Environmental protection
The sealed switch is a Saia specialty. In demanding
environments - wet, humid or dusty – even the most
sensitive signal can be switched reliably with IP67
rated products.
Typical Saia switch applications
Washing/drying machines
Coffee machines
■ Gaming machines
■ Electric showers
■ Power tools and garden equipment
■
■
Switches for Locking Mechanisms
Switches are found in numerous applications that
require a locking device. Whether it is a medical
application, an office automation application or a
door lock, switches provide an effective, cost-efficient
locking mechanism.
Security Applications
Hotel room door lock
Hotel safe lock
■ Prison door lock
■ Fire safety door opening lock
Sterilizer lock
Centrifuge lock
■ Blood analysis
machine lock
■
■
■
■
Office Automation
Consumer
Disk drive door lock
Personal computer
chassis lock
■ Docking station lock
■ Locks to hold peripherals in
place
■ Tape library index lock
■
■
Saia microswitches
Medical
[email protected]
Oven door lock for
selfcleaning function
■ Home safe lock
■
www.saia-switch.com
5
Switches in the Circuit Breaker Industry
Switches can be found in a variety of circuit breaker applications, for both
domestic and commercial installations:
Domestic Circuit
Breakers
■
Most commonly used
switches to trip breaker
Industrial Breakers
■
Higher rated switches
are typically used for
industrial applications due
to the higher
switching loads
Heavy Duty Industrial
Breakers
■
Used in commercial and
industrial applications for
switching heavy loads
Molded Case Breakers
■
Similar to domestic single
and double pole breakers
Reclosers
■
Oil or vacuum filled high
voltage breakers
Switches for domestic appliances
Switches are found in numerous applications in the
appliance industry.
Saia switches for domestic appliances
Switches used in domestic appliances have:
■ a wide range of actuating force options
■ reliability throughout the life of the product
■ compliance with relevant UL, CSA and ENEC
approvals
■ the ability to switch power or signal
■ environmental protection in wet or dusty
applications
Saia switches for vending and gaming
machines
Gaming machines demand:
■ dependability and reliability
■ a high degree of shock resistance in the
mechanism
■ good tactile feel
Other application examples:
Dispensing valves
Beverage dispensing valves
■ Product dispensers on vending machines
■ Coin changers on vending machines
■ Actuating devices on
commercial baking and food processing or
packaging equipment
■
■
Saia switches for power tools and
garden equipment
Switches used in power tools and garden
equipment must:
■ work reliably and safely, time after time
■ have appropriate environmental protection to resist
dust and moisture
6
Saia microswitches
[email protected]
www.saia-switch.com
Terminology: Snap-action switches
Positions – forces – movements
Free position
Position of the actuator, without any influence from an external force.
Operating position
Position of the actuator when contact changeover takes place.
Total travel position
Position of the actuator at the end of the allowed travel.
Release position
Position of the actuator when the switch mechanism resets.
Actuating force The force required to move the actuator from the free position to the operating position.
Release force
The value to which the applied force must be reduced to allow the mechanism to
reset after operation.
Force differential
Difference between actuating force and release force.
Pre-travel
Movement of the switch actuator between free and operating position.
Over-travel
Movement of the switch actuator beyond the operating position.
Total travel
The sum of pre-travel and over-travel.
Movement differential
Distance between operating position and release position.
Release travel
Movement of the switch actuator between release and total travel position.
Post release travel
Movement of the switch actuator between release and free position.
Total Travel
Post-release
Travel
Release Travel
Movement
Differential
Pretravel
Overtravel
Contact force – movement – diagram
Actuator or
auxiliary actuator
Guide
Free position
Operating Position
Final position
Release Force
Operation of actuator or auxiliary actuator
Saia microswitches
[email protected]
www.saia-switch.com
7
Actuating force – movement – diagram
Contact force – movement – diagram
8
Saia microswitches
[email protected]
www.saia-switch.com
Switch Technology
Approvals
Clearance Distance – the distance in air between ­current
carrying parts of opposite polarity or ­between any current
carrying part and an ­earthed‑(grounded) metal plate to
which the switch is attached.
Creepage Distance – the path along the surface of
­insulating material between current carrying parts of
opposite polarity or between any current carrying part and
an earthed (grounded) metal plate to which the switch is
attached.
Insulation Resistance – resistance as measured between
the normally closed terminals, or between all terminals
connected together and a metal plate to which the switch
is mounted. In dry conditions the value would be expected
to be greater than 5MΩ.
CSA mark. Switch meets CSA’s safety standards
UL Recognized Component Mark for Canada and the
United States
Single Throw – a switch which provided an ON-OFF or
OFF-ON function but does not change over from one
conductor to another. Such switches are usually referred to
as being «normally-closed only» or «normally-open only».
Switching Cycle – one complete switching operating from
free position into overtravel and back through release
position to free position.
ENEC Mark. Switch fulfills European EN standards. The two
digit number indicates which certification body has issued
the ENEC Certificate
Switch Resistance – a total resistance offered by a switch
in a circuit, as measured from terminal through mating
contacts, to terminal.
CQC Approval (China) is
available for certain switches
Transit Time – the time taken by the moving contact in a
snap-action mechanism to move from one stable position
to another.
Switch Life
Electrical Ratings
Electrical ratings given in the catalog
are ratings according to UL1054, CSA22,55 or
IEC61058-1.
Where these are not available, a general rating is given
based upon in-house laboratory testing.
The ratings tables should be considered as safe working
maximums for most applications. How­ever, switch
performance is influenced by a v­ ariety of factors, including:
■ Frequency of operation
■ Type of load
■ Amount of travel used
■ Temperature
■ Humidity
Please do not hesitate to contact Saia a
­ bout your specific
application.
a. Electrical Life – the electrical life data contained in this
catalog is based on laboratory controlled tests. In practice,
frequency and speed of operation, type of load, suppression, actuator travel used, ambient humidity and temperature and ­other environmental conditions can have a major
effect on switch life.
Individual assessments for specific applications are
possible and can be undertaken by Saia on request.
Please ask Saia if you would like an a
­ ssessment for your
specific application.
b. Mechanical Life – the figures quoted relate to the
number of switching cycles made without an electrical
load.
Switch Drawings
All drawings in this catalogue are third angle ­projection.
All dimensions in this catalogue are nominal, e
­ xcept where
specifically shown.
Saia microswitches
[email protected]
www.saia-switch.com
9
Application Technology
Contact Resistance
Shock and Vibration
If switches are likely to be subjected to shock or vibration,
select models with the highest avail­able actuating force.
Saia-switches feature low mass mechanisms which are
inherently resistant to shock and vibration.
If possible, the switches should be mounted so that the line
of acceleration is at right angles to the travel of the plunger.
The maximum avail­able overtravel should be used.
The contact resistance is the electrical resistance measured
at the terminals of the switch when the contacts are closed.
Direct Current
Direct current (DC) ratings where shown should not be
exceeded if destructive arcing and contact welding are to
be avoided.
Some form of arc suppression is recommended when
switches are used in DC circuits containing inductive
devices wired in series with the switch and the supply.
Lamp Loads
Because of the very high inrush currents associated with
incandescent lamps, applications should be subject to
individual assessment.
Capacitive Loads (including fluorescent lamps)
These can generate very high peak currents which can
cause contact welding. Applications should be subject to
individual assessment.
Inductive Loads
The general ratings tables included in this c
­ atalog provide
data for switches used to ­control ­inductive circuits at a
power factor of 0,5 (EN 0,6; UL 0,7 means HP-Rating 0,5).
Contact Materials
Switch Actuation
Direct Operation
Actuating plungers should be operated in the d
­ irection of
their axis. Where this is not possible the use of actuating
levers is recommended. For direct actuation the attack
angle should not e
­ xceed 30°.
Actuation by sliding cams.
Actuating Levers
Various lever types are available for use with Saia-switches.
They are generally stainless steel.
If roller or cam-follower levers are approached in the
reverse direction, care must be taken to ­ensure that the
angle of approach is small enough not to jam the lever.
Actuation by Cams
Cam-follower levers are particularly well suited for use with
plastic actuating cams.
Abrupt actuation or release of switch actuators shortens
the life of the switches.
For this reason cam should preferably provide a continuous
movement. Ideally they should be of cyclodal form.
Silver and silver alloys are the primary contact materials
used in Saia-switches.
The ratings tables shown refer to switches with silver/silver
alloy contacts.
Gold contacts should be specified when switches are to be
used in low voltage control or logic circuits, especially when
long periods of inactivity are expected or when atmospheres with a high sulphur content may be encountered.
Gold contacts are generally available in two forms; gold
plated silver alloy contacts, which can also be used at
higher currents or gold alloy cross-point contacts, which
are only suitable for switching low currents.
Please ask Saia if you would like an
assessment for your specitic application.
10
Saia microswitches
Long roller lever with continuous actuation
[email protected]
www.saia-switch.com
Environmental Protection
Health & Safety
Protection Classifications
The protection classes of Saia switches are in accordance
with IEC 529 and are covered by just four codes.
Saia has ensured, so far as it is reasonably practicable, that
their products are as described in this catalog or in other
current company ­publications, or as specified on Saia
­installation drawings. They have been so design­ed and
constructed as to be safe and without risk to health when
installed by suitably qualified personnel in accordance with
relevant legislation, codes of practice, regulations (including
IEE ­Wiring Regulations), the installation recommendations
offered by the company and the accepted rules of the art.
Their usage should be confined within the ratings limitations and parameters of‑application indicated in this
catalog and e
­ lsewhere.
Please contact us should you need additional i­nformation
or guidance.
IP40
Adequate protection against solids such as p
­ robing fingers
and small wires>1mm. Liquids however can gain access
and, unless externally protected, the switches should be
mounted in dry or well-sheltered positions.
IP54
Good protection against solid foreign bodies, ­including
dust and water splashing against the enclosure from any
direction.
Switches may be used out of doors if sheltered from the
worst of the elements or on factory m
­ achines subjected to
normal washing down procedures.
IP65
Complete protection against solids, including dust, and
against low pressure jets of water from all directions.
IP67
Complete protection against solids including dust and
against immersion in water at a specific pressure for a
specified time.
We reserve this code for switches which are f­actory sealed
and tested.
Switches should not be immersed in any ­liquid.
Working Temperatures
For details of the working temperatures applicable to
individual types, refer to the appropriate specification
sheet. Special versions suitable for temperatures outside
these ranges may be possible. Please contact us for
information.
All quoted temperatures assume stable operation. They
do not imply an ability to withstand excessive cycling
within the range.
Service Recommendations
Maintenance
Saia switches are not user-maintainable but they should be
kept in a reasonably clean, paint-free condition, especially
in the actuator area. Regular checks should be made on
mounting security and on the actuating medium to switch
actuator relationship.
Lubrication or the use of aqueous or chemical cleaning
fluids is not recommended.
Installation Recommendations
The following notes are intended merely to stress the most
important and general aspects of good switch installation
procedure and to provide some helpful additional information. Safety Consideration
Installation should only be carried out by competent
personnel.
Switch Positioning and Operation
Pre-loading of the switch actuator must be avoid­ed. The
actuating medium must be able to operate the switch
through the operating position into overtravel and then to
retract far enough to allow the switch to regain its free
position.
Saia recommends that the actuating medium should drive
the switch into at least 50% of the available overtravel.
All ratings tables shown in this catalog are based on the
use of all the available overtravel.
Mounting
Side mounting switches should be mounted on smooth,
firm, flat surfaces using the recommended screw size.
Avoid over tightening the screws. For added security, they
should be locked using epoxy resin. Do not attempt to
enlarge switch mounting holes and avoid over stressing the
switch. Use insulating material between the switch and
metallic plates to increase clearance on switches with open
terminals.
Saia microswitches
[email protected]
www.saia-switch.com
11
Connections
When soldering, overheating of the switch insulation must
be avoided. In certain circumstances, it may be advisable
to use a heat shunt. For optimum mechanical strength, the
conductor should be wrapped round the tip of the terminal
taking care to avoid loose strands of wire.
The soldering iron tip should be applied to the end of the
terminal while simultaneously ap­plying solder. Remove the
iron as soon as the s­ older has wetted the conductor and
terminal end. A‑soldering iron tip temperature of 350°C
(260°C/5 seconds for PCB Terminals) applied for a
maximum of 2-3 seconds should be adequate.
For lead-free solder, is usually needed an iron tip
temperature 15% higher.Health & Safety
Installation Recommendations (EN 61058-1)
Mounting Holes and Screw sizes
Mounting Screw Torque
Normal hole Diameter
(mm)(in)
Screw
For guidance when using
2,2/2,3
3,1/3,2
3,6/3,7
5,1/5,2
12
Metric Thread
Screw
Unified mild steel screws:
0,067/0,091 M2 #2
0,122/0,126 M3 #4
0,142/0,146M3,5 #6
0,201/0,205M5 #10
Saia microswitches
M2 or #2 screws
M3 or #4 screws M3,5 or #6 screws
M5 or #10 screws
0,15Nm
0,5Nm
0,8Nm
3,0Nm
[email protected]
www.saia-switch.com
Snap-action Microswitches
Subminiature
Type
Characteristics
XC
ide range of forces
w
and variants
■ long mechanical and
electrical life
■ solder, PCB and faston
terminals
■ compliant to glow wire
test IEC 60335-1, 4. ed.
■
Rating 250 VAC, 10 A max.
Dimensions (mm) 19,9 • 9,5 • 6,4
Actuator
plunger
mushroom plunger
■ plain levers
■ simulated roller lever/
cam follower
■ roller levers
X4
V4NS
t hermoplastic housing
long mechanical and
electrical life
■ solder, PCB and faston
terminals
■ compliant to glow wire
test IEC 60335-1, 4. ed.
s ealed (IP67)
solder 2,8 mm faston
and PCB terminals
■ pre-wired option
■ compliant to glow wire
test IEC 60335-1, 4. ed.
V4NCS
wide variety of levers
peg mounting option
■ pre-wired option
■ sealed (IP6K7)
■ solder and faston
terminals
■ PCB terminals
■
■
■
■
■
■
250 VAC, 12 A max.
250 VAC, 5 A max.
250 VAC, 5 A max.
19,9 • 9,7 • 6,4
20 • 10,3 • 6,4
20 • 10,3 • 6,4
plunger
plain levers
■ cam follower lever
■ roller levers
plunger
plain levers
■ roller levers
■ simulated roller lever/
cam follower
plunger
plain levers
■ roller levers
■ simulated roller lever/
■
■
■
■
■
■
■
■
UL, cUL, CSA, ENEC,
CQC
UL, CSA, ENEC
Automotive standard
22
27
31
Approvals ENEC, UL, cUL, CSA
Page 17
Miniature
Type
Characteristics
XGX3 340
ide range of forces
w
and ratings
■ long mechanical and
electrical life
■ solder, faston
and PCB terminals
■ compliant to glow wire
requirements
IEC 60335-1, 4. ed.
■
Rating 250 VAC, 26 A max.
Dimensions (mm) 27,8 • 15,9 • 10,3
Actuator
plunger
plain levers
■ roller levers
■ simulated roller levers
mm creepage and
8
clearance distance to
the actuator
■ long mechanical and
electrical life
■ solder, faston
and PCB terminals
■ compliant to glow wire
requirements
IEC 60335-1, 4. ed.
ipping contacts,
w
leaf spring mechanism
■ 3 mm contact gap,
■ compliant to glow
wire requirements
IEC 60335-1, 4. ed. as
optional item
■
■
250 VAC, 21 A max.
250 VAC, 16 A max.
27,8 • 15,9 • 10,3
28,8 • 20,4 • 10,1
plunger
straight lever
■ simulated roller levers
■ roller levers
plunger
roller lever
■ plain levers
■ simulated roller lever
■ moulded lever
■
■
■
■
■
■
UL, cUL, CSA, ENEC,
CQC
ENEC, UL
41
46
Approvals ENEC, UL, cUL, CSA
Page 36
Saia microswitches
[email protected]
www.saia-switch.com
13
Snap-action
­ icroswitches
M
Circuit diagram
④
①
XC
②
COMNO NC
Dimension
19.9 +0.25
-0.35
7.5
4.8
±0.2
3.1
9.5
4
2
3.6
1
1.3
+0.2
-0.3
2.3 +0.05
-0.02
2.35 +0.1
-0.15
2.4
2.5 +0.05
-0.02
2.3 +0.05
-0.02
9.5
5.25 +0.2
-0.25
±0.1
0.5
3.45
12.3 ±0.3
3.2
2.4
4
6.4 ±0.2
XC
Subminiature
XC
Characteristics
■ wide range of forces and variants
■ long mechanical and electrical life
■ solder, PCB and faston terminals
■ compliant to glow wire test IEC 60335-1, 4. ed.
Rating 250 VAC, 10 A max.
Dimensions (mm)19,9 • 9,5 • 6,4
Actuator ■ Plunger
■ mushroom plunger
■ plain levers
■ simulated roller lever/cam follower
■ roller levers
Approvals ENEC, UL, cUL, CSA
Preferred Range
Ordering Actuating Force
Reference(N)
(ozf)
Operating pos.
Terminal
Circuit
Actuator
Contacts
(mm)
(in)
Electrical rating
ENEC
UL/CSA
XCG3Z1 1,7
6,07 8,4 0,33 Solder
CO
Plunger
Ag 6(2) A
5A
XCG3-J1Z1 0,6 2,14 10,2 0,40 Solder
CO
Plain lever
Ag 6(2) A
5A
XCG3-S1Z1 0,7 2,49 15,6
0,61
Solder
CO
Roller lever
Ag 6(2) A
5A
XCG5Z1 1,7 6,07 8,4
0,33 Faston 2,8 × 0,5 mm
CO
Plunger
Ag 6(2) A
5A
XCG5-J1Z1 0,6 2,14 10,2 0,40 Faston 2,8 × 0,5 mm
CO
Plain lever
Ag 6(2) A
5A
XCG5-S1Z1 0,7 2,49 15,6 0,61
Faston 2,8 × 0,5 mm
CO
Roller lever
Ag 6(2) A
5A
XCG8-81Z1 1,7 6,07 8,4 0,33 PCB
CO
Plunger
Au none
0,1 A/125 VAC
XCG8-81-J1Z1 0,6 2,14 10,2 0,40 PCB
CO
Plain lever
Au none
0,1 A/125 VAC
XCG8-81-S1Z1 0,7 2,49 15,6 0,61 PCB
CO
Roller lever
Au none
0,1 A/125 VAC
XCF3Z1 3,0 10,70 8,4 0,33 Solder
CO
Plunger
Ag
10(3) A
10,1 A
XCF3-J1Z1 1,05
3,74 10,2 0,40 Solder
CO
Plain lever
Ag
10(3) A
10,1 A
XCF3-S1Z1 1,1 3,92 15,6
0,61 Solder
CO
Roller lever
Ag
10(3) A
10,1 A
XCG3-U1Z1 1,7
6,07
9,9
0,39
Solder
CO
Mushroom plunger
Ag 6(2) A
5A
XCG4-U1Z1 1,7
6,07
9,9
0,39
Faston 2,8 × 0,5 mm
CO
Mushroom plunger
Ag 6(2) A
5A
XCG8-U1Z1 1,7
6,07
9,9
0,39
PCB
CO
Mushroom plunger
Ag 6(2) A
5A
Saia microswitches
[email protected]
www.saia-switch.com
15
Specifications
Housing
Plunger
Mechanism
Functions
Contacts
Terminals
Temperature range ºC
Mechanical life
Protection
Mounting
Actuators
Contact Carrier
Melamine-Formaldehyd, Thermosetting
POM for T85, PPS for T125 and T150
Snap-action system with stainless steel tension spring
Change-over, NO, NC
Fine silver (Ag) or 10 µm Gold (Au), microprofile
Solder, faston and various PCB terminals (side of housing or side of lid, as well as 1/10” o lin pitch)
Between –40°C and +85°C (special version up to 140°C)
up to 5 • 10 7 cycles (Actuation: sinusoidal and up to 80% of overtravel)
Enclosure IP40
Side mounting through mounting holes
Stainless steel, PA66-GF35
CuZn or CuSn
Circuit diagram
Actuating force/travel
Contact force/travel
XC
②
④
①
COMNO NC
FP = Free Position
OP = Operating Position
Dimensions
19.9 +0.25
-0.35
4.8
3.1
200
+0.05
-0.02
2.3
9.5
0.5
+0.05
-0.02
5.25
±0.1
3.45
2
XCF
DC rating in VDC
2.5
1
3
5
10
48
3.6
2
60
1.3
4
110
80
+0.2
-0.3
+0.05
-0.02
2.3
100
9.5
+0.1
-0.15
Maximum DC rating
1
220
150
XCK
2.4
XCG
±0.2
XCH
7.5
XCC
2.35
Subaminiature
XC
2.4
+0.2
-0.25
40
36
30
24
20
15
12
10
0,1
4
3.2
6.4
0,2
0,4 0,6
DC in A
ohmic load
L
inductive load = 10 ms
R
±0.2
12.3 ±0.3
Recommended maximum electrical ratings
Voltage Resistive load
(VAC)
(A)
Motor load
(A)
Approvals ENEC
(A) (VAC)
(A)
Approvals UL
(VAC)
Motor load
3
2
3
1
0,3
10 (3)
6 (2)
5 (3)
3 (1)
1,5 (0,3)
125/250
250 250
250
250
1
XCF
XCG
XCK
XCC
XCH
250
250
250
250
250
10
6
5
3
1,5
1E4
5E4
1E4
5E4
5E4
250 250 250 250 250 10,1
5
5
2
1
⁄4 HP
–
–
–
–
Breaking capacities in the tables refer to Ag contacts.
16
Saia microswitches
[email protected]
www.saia-switch.com
XC
Actuator
Reference
Actuating
Force
Maximum
(N)
(ozf)
Release
Force
Minimum
(N)
(ozf)
Plunger
XCF..
XCG..
XCK..
XCC..
XCH..
3
10,70
1,7
6,07
1,2
4,28
0,6
2,14
0,35 1,24
0,5
0,3
0,2
0,1
0,07
1,78
1,07
0,71
0,36
0,24
8,8
8,8
8,8
8,8
8,8
0,34
0,34
0,34
0,34
0,34
8,4 8,4 +0,1
8,4 –0,3
8,4
8,4
Mushroom
Plunger
XCF..-U1
XCG..-U1
XCK..-U1
XCC..-U1
XCH..-U1
3
10,70
1,7
6,07
1,2
4,28
0,6
2,14
0,35 1,24
0,5
0,3
0,2
0,1
0,07
1,78
1,07
0,71
0,36
0,24
10,3
10,3
10,3
10,3
10,3
0,41
0,41
0,41
0,41
0,41
9,9 9,9 +0,1
9,9 –0,3
9,9
9,9
-J1 Lever
XCF..
XCG..
XCK..
XCC..
XCH..
1,05
0,6
0,42
0,22
0,13
3,74
2,14
1,49
0,78
0,46
0,16
0,08
0,056
0,025
0,02
0,57
0,28
0,19
0,08
0,07
12,2
12,2
12,2
12,2
12,2
0,48
0,48
0,48
0,48
0,48
-L1 Lever
XCF..
XCG..
XCK..
XCC..
XCH..
Width of lever 4,0 mm/0,16 in 1,1
0,7
0,43
0,23
0,14
3,92
2,49
1,53
0,82
0,49
0,17
0,09
0,058
0,026
0,021
0,6
0,32
0,2
0,09
0,07
17,6
17,6
17,6
17,6
17,6
-L6 Lever
1,05
0,6
0,42
0,22
0,13
3,74
2,14
1,49
0,78
0,46
0,16
0,08
0,056
0,025
0,02
0,57
0,28
0,19
0,08
0,07
-L9 Lever
XCF..
1,05 3,74
0,16
XCG..
0,6
2,14
0,08
XCK..
0,42 1,49
0,056
XCC..
0,22 0,78
0,025
XCH..
0,13 0,46
0,02
-S1 Lever
XCF.. 1,1
3,92
0,17
XCG.. 0,7
2,49
0,09
XCK.. 0,43 1,53
0,058
XCC.. 0,23 0,82
0,026
XCH..
0,14 0,49
0,021
Width of roller 4,0 mm/0,16 in, for high temperature use -T1 lever
-P5 Lever
XCF..
XCG..
XCK..
XCC..
XCH..
1,3
0,75
0,6
0,31
0,22
4,62
2,67
2,13
1,10
0,78
-P6 Lever
XCF..
XCG..
XCK..
XCC..
XCH..
1,05
0,6
0,42
0,22
0,13
3,74
2,13
1,49
0,78
0,46
Free
Operating Position
Position
Maximum
(mm) (in)
(mm)
(in)
Movement
Differential
Maximum
(mm) (in)
Total travelled
position
Maximum
(mm)(in)
0,33
0,33
+0,003
0,33–0,011
0,33
0,33
0,1
0,1
0,1
0,1
0,1
0,003
0,003
0,003
0,003
0,003
7,7
7,7
7,7
7,7
7,7
0,303
0,303
0,303
0,303
0,303
0,39
0,39+0,003
0,39–0,011
0,39
0,39
0,1
0,1
0,1
0,1
0,1
0,003
0,003
0,003
0,003
0,003
9,2
9,2
9,2
9,2
9,2
0,36
0,36
0,36
0,36
0,36
10,2 ± 1,0
10,2 ± 0,9
10,3 ± 0,9
10,3 ± 0,9
10,4 ± 0,9
0,401 ± 0,039
0,401 ± 0,035
0,405 ± 0,035
0,404 ± 0,035
0,409 ± 0,035
0,6
0,5
0,5
0,4
0,4
0,023
0,019
0,019
0,015
0,015
8,4
8,5
8,7
8,7
8,8
0,33
0,337
0,342
0,342
0,346
0,69
0,69
0,69
0,69
0,69
15,6 ± 1,1
15,6 ± 1,0
15,7 ± 1,0
15,7 ± 1,0
15,8 ± 1,0
0,614 ± 0,043
0,614 ± 0,039
0,618 ± 0,039
0,618 ± 0,039
0,622 ± 0,039
0,6
0,5
0,4
0,4
0,4
0,023
0,019
0,015
0,015
0,015
14
14,1
14,3
14,3
14,4
0,551
0,555
0,562
0,562
0,566
12,2
12,2
12,2
12,2
12,2
0,48
0,48
0,48
0,48
0,48
10,2 ± 1,0
10,2 ± 0,9
10,3 ± 0,9
10,3 ± 0,9
10,4 ± 0,9
0,401 ± 0,039
0,401 ± 0,035
0,405 ± 0,035
0,404 ± 0,035
0,409 ± 0,035
0,6
0,5
0,5
0,4
0,4
0,023
0,019
0,019
0,015
0,015
8,4
8,5
8,7
8,7
8,8
0,33
0,337
0,342
0,342
0,346
0,57
0,28
0,19
0,08
0,07
12,2
12,2
12,2
12,2
12,2
0,48
0,48
0,48
0,48
0,48
10,2 ± 1,0
10,2 ± 0,9
10,3 ± 0,9
10,3 ± 0,9
10,4 ± 0,9
0,401 ± 0,039
0,401 ± 0,035
0,405 ± 0,035
0,404 ± 0,035
0,409 ± 0,035
0,6
0,5
0,5
0,4
0,4
0,023
0,019
0,019
0,015
0,015
8,4
8,5
8,7
8,7
8,8
0,33
0,337
0,342
0,342
0,346
0,6
0,32
0,2
0,09
0,07
17,6
17,6
17,6
17,6
17,6
0,69
0,69
0,69
0,69
0,69
15,6 ± 1,2
15,6 ± 1,1
15,7 ± 1,1
15,7 ± 1,1
15,8 ± 1,1
0,614 ± 0,047
0,614 ± 0,043
0,618 ± 0,043
0,618 ± 0,043
0,622 ± 0,043
0,6
0,5
0,4
0,4
0,4
0,023
0,019
0,015
0,015
0,015
14,1
14,2
14,4
14,4
14,5
0,555
0,559
0,566
0,566
0,57
0,17
0,09
0,058
0,026
0,021
0,6
0,32
0,2
0,09
0,07
17,6
17,6
17,6
17,6
17,6
0,69
0,69
0,69
0,69
0,69
15,6 ± 1,1
15,6 ± 1,0
15,7 ± 1,0
15,7 ± 1,1
15,8 ± 1,0
0,614 ± 0,043
0,614 ± 0,039
0,618 ± 0,039
0,618 ± 0,043
0,622 ± 0,039
0,6
0,5
0,4
0,4
0,4
0,023
0,019
0,015
0,015
0,015
14
14,1
14,3
14,3
14,4
0,551
0,555
0,562
0,562
0,566
0,16
0,08
0,056
0,025
0,02
0,57
0,28
0,21
0,11
0,07
14,3
14,3
14,3
14,3
14,3
0,56
0,56
0,56
0,56
0,56
12,5 ± 1,1
12,5 ± 1,0
12,6 ± 1,0
12,6 ± 1,0
12,7 ± 1,0
0,49 ± 0,043
0,49 ± 0,039
0,5 ± 0,039
0,5 ± 0,039
0,5 ± 0,039
0,6
0,5
0,5
0,4
0,4
0,023
0,019
0,015
0,015
0,015
10,6
10,7
10,8
10,8
10,9
0,417
0,421
0,425
0,425
0,429
• •
• •
Width of lever 4,0 mm/0,16 in Saia microswitches
XCF..
XCG..
XCK..
XCC..
XCH..
[email protected]
www.saia-switch.com
17
Subminiature
Operating Characteristics
Subaminiature
XC
Ordering Reference
Basic type XCF
XCG
XCK
XCC
XCH
3
N
1,7 N
1,2 N
0,6 N
0,35 N
Circuits
4
5
No symbol, change-over (CO)
Normally closed (NC)
Normally open (NO)
Terminals
Solder
Faston
Faston PCB PCB PCB PCB PCB PCB PCB PCB 3
4
5
8
9
10
11
12
13
14
15
Version
V W Contacts
-81
-83
Example: XCF
4
3
V
-81
-J1
Z1
2,8 • 0,5 mm DIN
2,8 • 0,5 mm AMP
L = 4,5 mm
pitch 7,6 mm, L = 4,5 mm
formed to base
formed to lid
formed to base, pitch 7,6 mm
formed to lid, pitch 7,6 mm
L = 3,5 mm
pitch 7,6 mm, L = 3,5 mm
No symbol, Housing material MF, Europe up to 85°C, UL up to 90°C
(High temperature 125°C), Housing material MF / Plunger PBT, Europe up to 125°C, UL up to 130°C
(High temperature 140°C), Housing material MF / Plunger PPS, Europe up to 140°C, UL up to 150°C
No symbol, Ag (Ag)
µ profile Au 10 µm
Ag + 0,2 μ Au (gold plated)
Actuators
No symbol, plunger
-J1
Plain lever
-J2 Plain lever
-J5 Plain lever
-S1 Roller lever
-L1 Cam follower
-L6
Cam follower
-L9
Cam follower
-P5
Plastic lever
-P6
Plastic lever
-U1
Mushroom plunger
Other actuators on special request.
Approvals
Z1
10,70 ozf
6,07 ozf
4,28 ozf
2,14 ozf
1,24 ozf
18,0 mm (0,71 in)
25,0 mm (0,98 in)
40,0 mm (1,57 in)
16,0 mm (0,63 in)
16,0 mm (0,63 in)
18,0 mm (0,71 in)
18,5 mm (0,73 in)
16,0 mm (0,63 in)
18,0 mm (0,71 in)
No symbol, ENEC
UL, CSA
18
Saia microswitches
[email protected]
www.saia-switch.com
Thermoplastic
­Microswitches
Circuit diagram
④
①
②
X4 Standard
COMNO NC
Dimension
19.9 +0.25
-0.35
7.5
±0.2
3.1
+0.2
-0.3
2
3.6
4
9.65
2.3
1
1.3
+0.1
-0.15
+0.05
-0.02
2.35
2.4
2.5
+0.05
-0.02
2.3
9.5
0.5
±0.1
3.45
12.3 ±0,3
+0.05
-0.02
5.25
3.2
2.4
+0.2
-0.25
4
6.4
±0.2
X4
X4
Subminiature
Characteristics ■ thermoplastic housing
■ long mechanical and electrical life
■ solder, PCB and faston terminals
■ compliant to glow wire test IEC 60335-1, 4. ed.
Rating 250 VAC, 12 A max.
Dimensions (mm)19,9 • 9,7 • 6,4
Actuator ■ plunger
■ plain levers
■ cam follower lever
■ roller levers
Approvals UL, cUL, CSA, ENEC, CQC
Preferred Range
Ordering Actuating Force
Reference(N)
(ozf)
Operating pos.
Terminal
Circuit
Actuator
(mm)
(inch)
Contacts
ENEC
Electrical rating
UL/CSA
X4F303N1AA 3,30 11,87 8,4 0,3
Solder
CO
Plunger
Ag
12 (6) A
12 A
X4F305N1AA 3,30 11,87 8,4 0,3
Faston
CO
Plunger
Ag
12 (6) A
12 A
X4G303N1BB 2,00 7,19 8,4 0,3
Solder
CO
Plunger
Ag
6 (3) A
6A
X4G305N1BB 2,00 7,19 8,4 0,3
Faston
CO
Plunger
Ag
6 (3) A
6A
X4C303N1CC 0,75 2,70 8,4 0,3
Solder
CO
Plunger
Ag
3 (2) A
3A
X4C305N1CC 0,75 2,70 8,4 0,3
Faston
CO
Plunger
Ag
3 (2) A
3A
20
Saia microswitches
[email protected]
www.saia-switch.com
X4
Specifications
Circuit diagram
Actuating force/travel
Subminiature
HousingThermoplastic
Plunger
Thermoplastic
Mechanism
Snap-action system with stainless steel tension spring
Functions
CO (Change-over), NO (Normally Open), NC (Normally Closed)
Contacts
Fine silver (Ag), or 10 µm Gold (Au), microprofile
Terminals
Solder, faston, PCB, side-facing PCB and 'PCB terminals with 0,1” pitch
Temperature range ºC
Between –40°C and +85°C
Mechanical life
106 cycles minimum
Protection
Enclosure IP 40
Mounting
Side mounting or PCB Actuators
Stainless steel
Contact carrier
CuZn or CuSn
Contact force/travel
④
②
①
COMNO NC
X4 Standard
Standard
7.5
200
3.1
110
5
10
48
3.6
2
1.3
9.65
4
DC rating in VDC
+0.2
-0.3
+0.05
-0.02
60
2.3
+0.1
-0.15
100
80
1
2.5
220
150
±0.2
2.4
2.35
Maximum DC rating
X4F
19.9
Equidistant
+0.25
-0.35
X4G
X4C
Dimensions
+0.05
-0.02
2.3
9.5
0.5
5.25
±0.1
3.45
+0.05
-0.02
2.4
+0.2
-0.25
3.2
4
6.4
±0.2
40
36
30
24
20
15
12
10
0,1
0,2
0,4 0,6
DC in A
1
2
3
ohmic load
L
inductive load = 10 ms
R
12.3 ±0,3
Recommended maximum electrical ratings
Voltage
(VAC)
X4F 250
X4G 250
X4C 250
Resistive load
(A)
Motor load
(A)
Approvals ENEC
(A)
(VAC)
Approvals UL
(A)
(VAC)
12
6
3
6
3
2
12 (6)
6 (3)
3 (2)
12 6
3
1E4
5E4
5E4
250 250 250 125/250
125/250
125/250
Breaking capacities in the tables refer to silver contacts
Saia microswitches
[email protected]
www.saia-switch.com
21
X4
Subminiature
Operating Characteristics
Actuator
Reference
Actuating
Force
Maximum
(N)
(ozf)
Release
Force
Minimum
(N)
(ozf)
Free
Position
Maximum
(mm) (in)
Plunger
X4F
3,30
11,87
0,550 1,978
8,8 0,35
X4G
2,00
7,19
0,350 1,259
8,8 0,35
X4C
0,75
2,70
0,130 0,468
8,8 0,35
Operating
Position
Maximum
(mm)
(in)
8,4
} }
Movement
Differential
Maximum
(mm) (in)
0,33
0,2 0,008
+0,1
+0,004
8,4 –0,3 0,33
0,2 0,008
–0,01
8,4
0,33
0,2 0,008
Full
Overtravel
Position
(mm) (in)
7,7 0,303
7,7 0,303
7,7 0,303
J11 Lever
X4F
1,16
4,17
0,180 0,647 12,2 0,48
10,2 ±1,0
0,40 ±0,035
0,6 0,024
8,4 0,331
X4G
0,70
2,52
0,094 0,338 12,2 0,48
10,2 ±0,9 0,40 ±0,039
0,5 0,020
8,5 0,33
X4C
0,28
1,00
0,031 0,112 12,2 0,48
10,3 ±0,9
0,40 ±0,039
0,4 0,016
8,7 0,343
X4F
1,21
4,35
0,190 0,683 17,6 0,69
15,6 ±1,1
0,61 ±0,043
0,6 0,024 14,0 0,551
Width of lever 4,0 mm/0,16 in
L11 Lever
X4G
0,82
2,95
0,110 0,396 17,6 0,69
15,6 ±1,0
0,61 ±0,039
0,5 0,020 14,1 0,555
X4C
0,29
1,04
0,033 0,119 17,6 0,69
15,7 ±1,0
0,61 ±0,039
0,4 0,016 14,3 0,563
X4F
1,21
4,35
0,190 0,683 17,6 0,69
15,6 ±1,2
0,61 ±0,047
0,6 0,024 14,1 0,555
Width of lever 4,0 mm/0,16 in
S11 Lever
X4G
0,82
2,95
0,110 0,396 17,6 0,69
15,6 ±1,1
0,61 ±0,043
0,5 0,020 14,2 0,559
X4C
0,29
1,04
0,036 0,129 17,6 0,69
15,7 ±1,1
0,62 ±0,043
0,4 0,016 14,4 0,567
Width of roller 4,0 mm/0,16 in
22
Saia microswitches
[email protected]
www.saia-switch.com
X4
Ordering Reference
Terminals
03
04
05
08
09
10
11
12
13
14
15
21
22
23
24
25
Example: X4
F
3
03
K
1
A
A
J1
1
extra high force
high force
low force
Change-over (CO)
Normally closed (NC)
Normally open (NO)
Subminiature
Basic typeX4
Operating force F
G
C
Circuits diagram 3
4
5
Solder terminal
Faston terminal 2,8 • 0,5 mm DIN
Faston terminal 2,8 • 0,5 mm
PCB-terminal, length 4,5 mm
PCB-terminal, length 4,5 mm, (pitch 7,6)
PCB-terminal, formed to base
PCB-terminal, formed to lid
PCB-terminal, formed to base, (pitch 07,6)
PCB-terminal, formed to lid, (pitch 7,6)
PCB-terminal, length 3,5 mm
PCB-terminal, length 3,5 mm, (pitch 7,6)
Equidistant PCB-terminals, length 8,15 mm (pitch 7,5)
Equidistant PCB-terminals formed to base (pitch 7,5)
Equidistant PCB-terminals formed to lid (pitch 7,5)
Equidistant faston terminals 2,8 • 0,5 mm DIN (pitch 7,5)
Equidistant solder terminals (pitch 7,5)
Body N
PA66GF25 for terminal types 03 to 15 only
P
PA66GF25 (pitch 7,5) for equidistant terminal types 21 to 25 only
R
PA66GF25 (pitch 7,5 with moulded pegs) for equidistant terminal types 22 and 23 only
Contacts material1
Silver/Silver
8
Gold microprofile (Crosspoint) contacts
9
Gold-plated
UL/C-UL ratings A
12 A, 125/250 VAC B
6 A, 125/250 VAC C
3 A, 125/250 VAC D
0,1 A, 125 VAC N
no approvals
EN/IEC ratings A
12 (6) A, 250 V~ 1E4 T85 µ approved
B
6 (3) A, 250 V~ 5E4 T85 µ approved
C
3 (2) A, 250 V~ 5E4 T85 µ approved
F
10 (4) A, 250 V~ 1E4 T125 µ approved
L 1 A, 30 V = not approved
M
0,3 A, 30 V~ 1E4 not approved
N
no approvals
Type of actuators
No symbol, without lever
J1
Plain lever 18,0 mm (0,71 in)
L1
Cam follower16,0 mm (0,63 in)
S1
Roller lever 16,0 mm (0,63 in)
Other actuators and lengths available
Actuator position
1
2
Saia microswitches
No symbol, without lever
Lever above terminal 1
Lever above terminal 2
[email protected]
www.saia-switch.com
23
Sealed
Microswitches
Circuit diagram
DIMENSIONS
DIMENSIONS
VERSION
V4N - STANDARD VERSION
2.60
[0.10]
10.16
[0.40]
NORMALLY
OPEN
(BLUE)
Dimension
5.082.60
[0.20]
[0.10]
10.16
[0.40]
5.16 9.53±0.05
[0.20]
[0.375]
5.30
10.80
Ø2.25+0.1
[0.21]
[0.43]
[0.09]
7.50
MOUNTING HOLE
[0.30]
MAX 8.90 OPERATING
POSITION
[0.14]
6.45
6.45
[0.25]
Ø2.30
[0.09]
(NO) BLUE
(COM) RED
(NC) YELLOW
5.16 9.53±0.05
[0.20]
[0.375]
MAX 20.00 MIN 500
[0.79]
[19.7]
[0.25]
Ø2.30
[0.09]
FREE
POSITION
Ø2.25+0.1
[0.09]
MOUNTING HOLE
FREE
POSITION
[0.04]
+0.1
2.25-0.0
[0.09]
[0.30]
MAX 7.70
[0.04]
+0.1
2.25-0.0
[0.09]
1.00
[0.30]
2.95
[0.12]
5.08
[0.20]
MIN 500
[19.7]
MAX 20.00
[0.79]
(NO) BLUE
(COM) RED
(NC) YELLOW
6.45
[0.25]
MAX 20.00
[0.79]
6.45
[0.25]
MAX 20.00
[0.79]
1.00
10.80
Ø2.54±0.05
[0.43]
[0.1]
7.50 HOLE
MOUNTING
[0.30]
MAX 8.90 OPERATING
POSITION
[0.14]
2.95
[0.12]
[0.09]
MOUNTING HOLE
MAX 7.70
Ø1.70
[0.07]
3.60
[0.14]
Ø1.70
[0.07]
3.60
[0.14]
0.50±0.025
[0.02]
9.53±0.05
[0.09]
[0.375]
MOUNTING
HOLE
5.30
[0.21]
Ø2.54±0.05
[0.1]
MOUNTING HOLE
2
MAX 2.50
[0.10]
4
Ø2.30
[0.09]
FREE
POSITION
OPERATING
POSITION
Ø2.30
[0.09]
FREE
POSITION
1.00
[0.04]
MAX 2.50
[0.10]
1
2.25+0.1
[0.09]
2
0.50±0.025
[0.02]
[0.10]
9.53±0.05
MOUNTING HOLE
[0.375]
[0.10]
MOUNTING HOLE
④
DIMENSIONS
10.80
[0.43]
7.50
[0.30]
OPERATING
POSITION
MAX 7.15
[0.28]
[0.30]
MAX 7.70
1.00
[0.04]
5.30
[0.21]
4
2.25+0.1
[0.09]
1
NORMALLY
CLOSED
(Yellow)
V4NS - SEALED VERSION
V4NS - SEALED VERSION
10.80
[0.43]
7.50
[0.30]
[0.30]
MAX 7.70
MAX 7.15
[0.28]
5.30
[0.21]
②
①
COMMON
(Red)
DIMENSIONS
V4NC
PREWIRED VERSION WITH
PREWIRED
CABLEVERSION
BOX WITH CABLE BOX
FOR TYPE CODING KEY
FORPLEASE
TYPE CODING
CONTACT
KEY
SAIA
PLEASE CONTACT SAIA
5.08
[0.20]
5.16
10.16
2.605.08
10.16
Ø2.25+0.1
[0.40]
[0.10][0.20]
[0.40]
[0.09]
MOUNTING HOLE
9.53±0.05
5.16 9.53±0.05
[0.375]
[0.375]
19.85±0.15
[0.78]
1
6.40
Ø2.54+0.5
Ø1.70±0.05
[0.1]
MOUNTING
[0.07] HOLE
Ø1.70±0.05
[0.07]
2.60
2.95
[0.10][0.12]
(NO) GREY
(COM) BLACK
(NC) BLUE
2.95
[0.12]
6.40
6.40
[0.25]
[0.25]
6.40
K1
6.40
K1
6.40
K2
6.40
K2
(NO) GREY
(COM) BLACK
(NC) BLUE
19.85±0.15
[0.78]
2
2
STANDARD CABLE FLRY
STANDARD
0.5mm WITH
CABLE
MAX.
FLRY
OUTSIDE
0.5mm DIAMETER
WITH MAX.1.8mm
OUTSIDE DIAMETER 1.8mm
STANDARD CABLE BOX
STANDARD
IS K2
CABLE BOX IS K2
MAX 9.7
MAX 9.7
MAX 5.5
MAX 5.5
3.55±0.2
[0.14]
1.75
[0.07]
3.55±0.2
[0.14]
Ø2.30
[0.09]
7.70±0.1
[0.30]
1.75
[0.07]
1.00
[0.04]
4
Ø2.30
[0.09]
MAX 8.7
2
0.50 (3x)
[0.02]
25+0.1
0.09]
NTING HOLE
1
Ø2.54+0.5
[0.1]
[0.02]MOUNTING HOLE
0.50 (3x)
Ø4.40±0.05
[0.17]
MAX 8.7
4
7.50
[0.30]
7.70±0.1
[0.30]
7.00±0.15
[0.28]
OPERATING
POSITION
END
POSITION
[0.28]
2.40±0.1
[0.10]
FREE
POSITION
2
2.40±0.1
[0.10]
7.50
[0.30]
5.30 Ø4.40±0.05
[0.21]
[0.17]
2.25±0.1
[0.09]
10.80
[0.43]
2.25±0.1
[0.09]
5.30
[0.21]
1.00
[0.04]
10.80
[0.43]
6.40
K3
K3
V4NS
V4NS
Characteristics ◼ sealed (IP67)
◼ solder, 2,8 mm faston and PCB terminals
◼ pre-wired option
◼ compliant to glow wire test IEC 60335-1, 4. ed.
Rating 250 VAC, 5 A (3 A prewired UL)
Dimensions (mm)20 × 10,3 × 6,4
Subminiature
Subminiature
Actuator ◼ plunger
◼ plain levers
◼ roller levers
◼ simulated roller lever/cam follower
Approvals UL, CSA, ENEC
Preferred Range
Ordering Actuating Force
Sealing
Reference(N)
(ozf)
Operating pos.
(mm)
(in)
Terminal
Circuit
Actuator
Contacts
Electrical rating
V4NST7UL 2,50
9,0 IP67
8,40 0,33
Solder
CO
Plain plunger
Ag
250 VAC, 5 A
V4NSUL 2,50 9,0
IP67
8,40 0,33 Pre-wired
CO
Plain plunger
Ag
250 VAC, 5 A
V4NST7Y1UL 0,90 3,2 IP67
10,6 0,42 Solder
CO
Straight lever
Ag
250 VAC, 5 A
V4NSY1UL 0,90 3,2 IP67
10,6 0,42 Pre-wired
CO
Straight lever
Ag
250 VAC, 5 A
V4NST7YRUL 0,90 3,2 IP67
15,6 0,62 Solder
CO
Roller lever
Ag
250 VAC, 5 A
V4NSYRUL 0,90 3,2 IP67
15,6 0,62 Pre-wired
CO
Roller lever
Ag
250 VAC, 5 A
Saia microswitches
[email protected]
www.saia-switch.com
25
V4NS
0.50±0.025
[0.02]
[0.10]
MOUNTING HOLE
②
NORMALLY
CLOSED
(Yellow)
①
2.60
[0.10]
10.16
[0.40]
[0.09]
MOUNTING HOLE
5.08
[0.20]
NORMALLY
OPEN
(BLUE)
V4N - STANDARD VERSION
V4N - STANDARD VERSION
OPERATING
POSITION
9.53±0.05
[0.09]
[0.375] HOLE
10.80 MOUNTING
5.30
[0.21]
2.60
5.08 [0.43]
10.16
5.08
[0.10]
[0.20]
[0.40]
[0.20]
7.50
[0.30]
[0.17]
10.16
WIRED VERSION
WITH CABLE
BOXVAC
V4NSUL
250
3 (0,75 pf)
FOR TYPE CODING
KEY PLEASE CONTACT
SAIA
250
VACSAIA 5
2
YPE CODING KEY PLEASE CONTACT
DIMENSIONS
DIMENSIONS
UL 1054/CSA
22,2 No. 55 - 6,000 operations - 65°C
EN61058-1, T85, 10,000 operations
V4NC
General rating - 50,000 operations (85°C)
General rating - 50,000 operations (85°C)
2
4
1
Ø2.54+0.5
4
Ø2.30
[0.09]
3.55±0.2
1.00
[0.04]
1.00
[0.04]
K3
2
Ø2.30
[0.09]
www.saia-switch.com
1
Ø2.54+0.5
1.75
[0.07]
K3
Ø4.40±0.05
[0.17]
[0.14]
K2
6.40
K2
[email protected]
6.40
Ø4.40±0.05
[0.17]
1.75
[0.07]
6.40
5.30
[0.21]
7.50
[0.30]
2.40±0.1
[0.10]
MAX 8.7
FREE
POSITION
6.40
10.80
[0.43]
7.50
[0.30]
7.00±0.15
MAX 9.7[0.28]
FREE
2.40±0.1
POSITION
[0.10]
OPERATING
POSITION
END
POSITION
7.00±0.15
[0.28]
MAX
9.7
K1
K1
Saia microswitches
5.30
[0.21]
7.70±0.1
[0.30]
10.80
[0.43]
2.25±0.1
[0.09]
3
3
MAX 8.7
6.40
6.40
[0.25]
General rating - 50,000 operations (85°C)
19.85±0.15
[0.78]
General rating - 50,000 operations (85°C)
MAX 5.5
MAX 5.5
26
2.95
[0.12]
[0.375]
OPERATING
POSITION
END
POSITION
40
3
3
Ø1.70±0.05
[0.07]
2.60
UL 1054/CSA 22,2 No. [0.09]
55 - 6,000 [0.20]
operations
- 65°C
[0.40]
[0.10]
MOUNTING
HOLE
EN61058-1, T85, 10,000
operations
5.16 9.53±0.05
V4NC
3.55±0.2
5.08
[0.14]
Ø2.54+0.5
[0.1]
MOUNTING HOLE
[0.02]
Ø2.25+0.1
3.55±0.2
0.50 (3x)
1.75
[0.07]
1
4
V4NST7UL 250 VAC
5 (0,75 pf)
250 VAC
5
2
0 - 15 VDC 5
3
15
30
VDC
5
3
PREWIRED VERSION WITH CABLE BOX
0 - 15 VDC
15 - 30 VDC
Ø2.30
[0.09]
MAX 20.00
[0.79]
2
2.95
[0.12]
[0.09]
MOUNTING HOLEØ4.40±0.05
1.00
[0.04]
10.16
[0.40]
Ø1.70
[0.07]
3.60
[0.14]
MAX 2.50
[0.10]
2
0.50±0.025
[0.02]
MAX 20.00
[0.79]
Approval
FREE
POSITION
OPERATING
POSITION
4
MAX 2.50
[0.10]
2.25+0.1
[0.09]
1
[0.14]
Motor load
(A)
Ø2.30
[0.09]
6.45
[0.25]
Resitive load
(A)
1.00
[0.04]
MAX 7.15
[0.28]
7.00±0.15
[0.28]
[0.10]
Recommended maximum electrical ratings
Voltage
(max)
2
6.45
[0.25]
MAX 20.00
[0.79]
4
0.50±0.025
(NO) BLUE
[0.02]
[0.10]
(COM) RED
9.53±0.05
(NC)MOUNTING
YELLOW HOLE
[0.375]
[0.10]
(NO) BLUE
MOUNTING HOLE
(COM) RED
(NC) YELLOW 2.60
10.80
[0.43]
7.50
[0.30]
2.40±0.1
[0.10]
5.16 9.53±0.05
[0.20]
[0.375]
2.25+0.1
[0.09]
1
V4NC
5.30
[0.21]
[0.30]
MAX 7.70
MAX 7.70
DIMENSIONS
10.80
[0.43]
7.50
[0.30]
Ø2.30
[0.09]
1.00
[0.04]
MAX 7.15
[0.28]
Ø2.30
[0.09]
[0.30]
[0.25]
FREE
POSITION
MAX 8.90 OPERATING
POSITION
[0.14]
FREE
POSITION
5.30
[0.21]
6.45
[0.25]
6.45
OPERATING
POSITION
END
POSITION
5.16 9.53±0.05
[0.20]
[0.375]MIN 500
[19.7]
MAX 20.00
[0.79]
MAX 8.90 OPERATING
POSITION
[0.14]
[0.04]
1.00
+0.1
2.25-0.0
[0.09]
[0.30]
MAX 7.70
Ø2.25+0.1
[0.09]
MOUNTING HOLE
FREE
POSITION
MIN 500
[19.7]
10.80
[0.43]
Ø2.25+0.1
7.50
[0.09][0.30]
MOUNTING HOLE
7.50
[0.30]
[0.04]
1.00
[0.30]
+0.1
2.25-0.0
[0.09]
Ø2.54±0.05
[0.1]
MOUNTING HOLE
MAX 7.70
5.30
[0.21]
Ø2.54±0.05
5.30 [0.1]10.80
[0.21]
MOUNTING[0.43]
HOLE
3.60
[0.14]
DIMENSIONS
FREE
POSITION
DIMENSIONS
MAX 20.00
[0.79]
V4NST7
6.45
[0.25]
V4NS - SEALED VERSION
Dimension
- SEALED
VERSION
V4NS
7.70±0.1
[0.30]
DIMENSIONS
NSIONS
7.70±0.1
[0.30]
④
2.25±0.1
[0.09]
COMMON
(Red)
9.53±0.05
[0.375]
3.60
[0.14]
Circuit diagram
2
MAX 2.50
[0.10]
2.25+0.1
[0.09]
4
FREE
POSITION
OPERATING
POSITION
1.00
[0.04]
[0.30]
1
2.25±0.1
[0.09]
Flame-retardant glass-fibre reinforced nylon
DIMENSIONS
Polyacetal (POM)
V4N - STANDARD
VERSIONsteel spring
Snap-action coil spring mechanism
with stainless
Change-over, normally closed or normally open
5.30
10.80
[0.21]
[0.43]
Silver
7.50
Gold flashed
[0.30]
–40°C to +85°C
3 • 106 cycles minimum (impact free actuation)
IP67 enclosure, IP40 Flux proof terminal entries
Plain lever, cam follower, Roller lever
Insulating sheet - N04619, Clip-on terminal cover - TC102, Long overtravel actuator - QA4
MAX 7.15
[0.28]
Housing
Plunger
Mechanism
Functions
Contacts
Terminals
Temperature range ºC
Mechanical life
Protection
Actuators
Accessories
MAX 7.70
Subminiature
Specifications
V4NS
Operating Characteristics
Actuator
Reference
Plunger
Ø2.3
[0.09]
Release
Force
Minimum18.5
]
[0.73
(N)
(ozf)
2,5
2,5
9,00
9,00
0,30
0,30
1,00
1,00
9,2
9,2
0,36
0,36
V4NST7Y1UL18.5 0,9
]
V4NSY1UL [0.73 0,9
3,20
3,20
0,07
0,07
0,25
0,25
13,2
13,2
0,52
0,52
0,9
0,9
3,20
3,20
0,07
0,07
0,25
0,25
16,1
16,1
0,9
0,9
3,20
3,20
0,07
0,07
0,25
0,25
17,8
17,8
18.0
1]
[0.7
V4NST7UL
V4NSUL
Free
Operating
Position
Position
Maximum
(mm) (in)
(mm)
(in)
8,4 ± 0,3 0,33 ± 0,012
8,4 ± 0,3 0,33 ± 0,012
Movement
Differential
Maximum
(mm) (in)
0,1
0,1
0,004
0,004
10,6 ± 1,2 0,42 ± 0,05
10,6 ± 1,2 0,42 ± 0,05
0,4
0,4
0,016
0,016
0,70
0,70
13,3 ± 1,2 0,61 ± 0,05
13,3 ± 1,2 0,61 ± 0,05
0,4
0,4
0,016
0,016
0,70
0,70
15,6 ± 1,2 0,61 ± 0,05
15,6 ± 1,2 0,61 ± 0,05
0,4
0,4
0,016
0,016
Subminiature
Y1 lever
18.0
1]
[0.7
Ø2.3 [0.09]
Actuating
Force
Maximum
(N)
(ozf)
Width of lever 4,0 mm/0,16 in
18.0
1]
[0.7
YC lever
V4NST7YCUL
V4NSYCUL
Width of lever 4,0 mm/0,16 in
YR lever
V4NST7YRUL
V4NSYRUL
Width of lever 4,0 mm/0,16 in
Over travel: Plunger can be depressed flush with housing. The housing should not be used as an end stop.
Saia microswitches
[email protected]
www.saia-switch.com
27
V4NS
Ordering Reference
Basic type V4N
Type of sealing/ S
Overtravel B
Sealed IP67
Sealed IP67
Terminals
T7
T8
T9
T81
T82
No symbol, pre-wired 500 mm with cable box (V4NS/B only)
Solder
2,95 • 0,5 • 3,6 long
PCB
0,8 • 0,5 • 4,0 long
Faston
2,8 • 0,5 • 8,1 long
Formed PCB
0,8 • 0,5 • 3,8 long
Formed PCB
0,8 • 0,5 • 3,8 long
Circuit
C2
C4
No symbol, change-over
Normally closed
Normally open
Actuators
Y1
Y2
Y3
YC
YR
QA
No symbol, without lever
Plain lever
18,0 mm
Plain lever
25,0 mm
Plain lever
32,0 mm
Cam follower lever 18,5 mm Roller lever
16,0 mm
Long overtravel actuator available on request
Example: V4N
S
T7
C2
Y1
0
X
UL
standard travel
with extended overtravel (0,5 mm)
Subminiature
Subminiature
Other actuators on special request
Actuator Position
0
No symbol, without lever, or lever fitted at the end nearest to the Plunger
With lever fitted at end opposite to plunger
Contact Material
X
Approvals UL
No symbol, Fine silver
Gold alloy on silver palladium crosspoint
Special Features /□□□□
Saia specialise in customer specific solutions.
Additional product variants are available or can be provided. 
If your requirements cannot be satisfied from the options listed,
please contact www.saia-burgess.com or your local SB outlet.
28
UL, CSA and ENEC approval
Saia microswitches
[email protected]
www.saia-switch.com
V4NCS
V4NCS
Characteristics ■ wide variety of levers
■ peg mounting option
■ pre-wired option
■ sealed (IP6K7)
■ solder and faston terminals
■ PCB terminals
Rating 250 VAC, 5 A
Dimensions (mm)20 × 10,3 × 6,4
Subminiature
Subminiature
Actuator ■ plunger
■ plain levers
■ roller levers
■ simulated roller levers
Approvals Automotive standard
Preferred Range
Ordering Actuating Force
Sealing
Reference(N)
(ozf)
Operating pos.
(mm)
(in)
Terminal
Circuit
Actuator
Contacts
Electrical rating
V4NCS 2,5 8,992 Sealed IP6K7
8,40 0,331 Cable 500 mm
CO
Plunger
Ag
250 VAC, 5 A
V4NCSA1 0,9 3,237 Sealed IP6K7
10,80 0,425 Cable 500 mm
CO
Plain lever
Ag
250 VAC, 5 A
V4NCSAR 0,9 3,237 Sealed IP6K7
15,90 0,626
Cable 500 mm
CO
Roller lever
Ag
250 VAC, 5 A
Saia microswitches
[email protected]
www.saia-switch.com
29
V4NCS
DIMENSIONS
9.53±0.05
[0.375]
2.60
[0.10]
10.16
[0.40]
Ø1.70
[0.07]
3.60
[0.1
[0.10]
MOUNTING HOLE
M
0.50±0.025
[0.02]
2.95
[0.12]
[0.09]
MOUNTING HOLE
5.08
[0.20]
V4NS - SEALED VERSION
Specifications
) GREY
M) BLACK
BLUE
DIMENSIONS
FREE
POSITION
MAX 8.90 OPERATING
POSITION
[0.14]
[0.04]
1.00
+0.1
2.25-0.0
[0.09]
[0.30]
MAX 7.70
6.45
[0.25]
[0.79]
Housing
Glass fibre reinforced
Polyamide (PA 6.6)
Plunger
Polyacetal POM/(PA 4,6)
6.45
5.30
10.80
Mechanism
coil spring
mechanism
with stainless steel spring
Ø2.25+0.1
Ø2.54±0.05Snap-action
[0.21]
[0.43]
[0.25]
[0.1] Change-over, normally closed or[0.09]
Functions
normally open
7.50
Ø2.30
MOUNTING HOLE
MOUNTING HOLE
Contacts
Fine Silver, Gold[0.30]
plate on silver, Gold alloy on silver palladium (crosspoint)
[0.09]
Terminals
Gold flashed
Temperature range ºC
–40°C to +85°C (120°C option)
Mechanical life
3 • 106 cycles minimum (impact free actuation) Protection
IP67 enclosure, IP40 Flux proof terminal entries
Mounting
Side mounting (moulded mounting pegs on request)
Actuators
Plain lever, cam follower, roller lever, simulated roller (cam follower) lever
Accessories
Lug mounting frame, clip-on terminals cover, insulating sheet
(NO) BLUE
(COM) RED
(NC) YELLOW
5.16 9.53±0.05
[0.20]
[0.375]
Circuit diagram
MAX 20.00
[0.79]
Ø4.40±0.05
[0.17]
7.50
[0.30]
2.40±0.1
[0.10]
7.00±0.15
[0.28]
OPERATING
POSITION
END
POSITION
5.30
[0.21]
2
4
Ø2.30
[0.09]
1
Ø2.54+0.5
[0.1]
MOUNTING HOLE
0.50 (3x)
[0.02]
3.55±0.2
10.80
[0.43]
Dimensions
[0.14]
④
1.75
[0.07]
[19.7]
NORMALLY
OPEN
(BLUE)
7.70±0.1
[0.30]
①
1.00
[0.04]
(BLACK)
NORMALLY
CLOSED
MIN
500
(GREY)
2.25±0.1
[0.09]
V4NC
②
COMMON
FREE
POSITION
5.08
10.16
Ø2.25+0.1
[0.09]
[0.20]
[0.40]
PREWIRED MOUNTING
VERSION
WITH
CABLE
BOX
HOLE
5.16 9.53±0.05
FOR TYPE CODING KEY PLEASE [0.375]
CONTACT
Ø1.70±0.05
[0.07]
2.60
[0.10]
(NO) GREY
(COM) BLACK
(NC) BLUE
2.95
[0.12]
6.40
SAIA
[0.25]
19.85±0.15
[0.78]
Prewired version with cable box
For type coding key please contact Saia
Standard cable FLRY 0,5 mm2 with max. outside diameter 1.8 mm
Standard cable box is K2
MAX 8.7
MAX 9.7
MAX 5.5
Subminiature
MAX 20.00
6.40
K1 (2 cables
K1 only)
6.40
K2
6.40
K3
Recommended maximum electrical ratings
Voltage
(max)
Resitive load
(A)
Motor load
(A)
Approval
V4NCST 250 VAC
5
2
General rating (85°C)
0 - 15 VDC 5
3
General rating (85°C)
2
15
- 30 VDCCABLE
5 FLRY 0.5mm
3 WITH
General rating
(85°C)1.8mm
STANDARD
MAX. OUTSIDE
DIAMETER
V4NCS 250 VAC
5
General rating (85°C)
STANDARD CABLE
BOX IS K22
0 - 15 VDC 3
3
General rating (85°C)
15 - 30 VDC 3
3
General rating (85°C)
30
Saia microswitches
[email protected]
www.saia-switch.com
V4NCS
Operating Characteristics
Actuating
Force
Maximum
(N)
(ozf)
Release
Force
Minimum
(N)
(ozf)
Free
Operating
Position
Position
Maximum
(mm)
(in)
(mm)
(in)
Plunger
V4NCS..
V4NCSB..
2,5
2,5
8,992 0,5
8,992 0,5
1,798
1,798
9,2
9,7
0,362
0,382
8,4 ± 1,3
8,9 A1 Lever
V4NCS..
V4NCSB..
0,9
0,9
3,237 0,1
3,237 0,1
0,359
0,359
13,4
14,8
0,527
0,582
3,237 0,1
3,237 0,1
0,359
0,359
16,1
17,6
0,634
0,693
3,237 0,1
3,237 0,1
0,359
0,359
18,1
19,2
0,712
0,756
6,474 0,2
6,474 0,2
0,719
0,719
10,7
11,5
0,421
0,453
9,3– ± 0,7
10,1 6,474 0,2
6,474 0,2
0,719
0,719
15,8
16,5
0,622
0,649
14,7 ± 0,6
15,4 Movement
Differential
Maximum
(mm) (in)
}
0,331 ± 0,0120,1 0,004
0,35 0,1 0,004
}
10,8 ± 1,3
12,4 }
0,425 ± 0,0510,4 0,016
0,488 0,4 0,016
13,4 ± 1,3
15,1 }
0,527 ± 0,0510,4 0,016
0,594 0,4 0,016
15,9 ± 1,2
17,3 }
0,626 ± 0,0470,4 0,016
0,681 0,4 0,016
}
0,366 ± 0,0270,2 0,008
0,397 0,2 0,008
}
0,579 ± 0,0230,2 0,008
0,606 0,2 0,008
}
Width of lever 4,0 (mm)/0,16 (in)
AC Lever
V4NCS..
V4NCSB..
0,9
0,9
}
Width of lever 4,0 (mm)/0,16 (in)
AR Lever
V4NCS..
V4NCSB..
0,9
0,9
}
Width of lever 4,0 (mm)/0,16 (in)
A10 Lever
V4NCS..
V4NCSB..
1,8
1,8
}
Width of lever 4,0 (mm)/0,16 (in)
AR0 Lever
V4NCS..
V4NCSB..
1,8
1,8
}
Width of lever 4,0 (mm)/0,16 (in)
Operating characteristics shown above are specified from mounting hole centres.
Over travel: Flush with case. (7,8 mm min) The case should not be used as an end stop.
Saia microswitches
[email protected]
www.saia-switch.com
31
Subminiature
Actuator
Reference
V4NCS
Subminiature
Ordering Reference
Basic typeV4NC
Type of sealing S
B
Sealed IP6K7
Sealed IP6K7
Terminals
T7
T8
T9
T81
T82
No symbol, pre-wired 500 mm with cable box (V4NCS/B only)
Solder
2,95 × 0,5 × 3,55 long
PCB
0,8 × 0,5 × 4,0 long
Faston
2,8 × 0,5 × 9,5 long
Formed PCB
0,8 × 0,5 × 3,8 long
Formed PCB
0,8 × 0,5 × 3,8 long
Circuit
C2
C4
No symbol, change-over
Normally closed
Normally open
Example: V4NC
S
T7
C4
A1
0
G
standard travel
with extended overtravel (0,5 mm)
Actuators
No symbol, without lever
A1
Plain lever
18,0 mm
A2
Plain lever
25,0 mm
A3
Plain lever
32,0 mm
A7
Plain lever
60,0 mm
AC
Cam follower lever 18,5 mm (AC1)
AR
Roller lever
16,0 mm (AR1)
AP
Roller lever
17,9 mm (AR2)
Other actuators on special request
Actuator Position
0
No symbol, without lever, or lever fitted at the end nearest to the Plunger
With lever fitted at end opposite to plunger
Contact Material
X
No symbol, Ag
Gold alloy on silver palladium crosspoint (AUX)
Special/□□□□
Features
Saia specialise in customer specific solutions.
Additional product variants are available or can be provided. 
If your requirements cannot be satisfied from the options listed,
please contact www.saia-burgess.com or your local SB outlet.
32
Saia microswitches
[email protected]
www.saia-switch.com
­
Thermoset plastic
Microswitches
Circuit diagram
NORMALLY
CLOSED
NORMALLY
OPEN
COMMON
XG
Dimension
±0.2
+0,1
0
+0,1
0
5,8
3.1
±0.1x0.8
10.3 ±0.2
+0,1
0
±0.1x0.8
10.3 ±0.2
3.1
6.3
±0.2
3.9
20.2
2
4
2.8
11.5
6.3
XG
2.92
1
±0.1
±0,2
17.15
Ø 1.75 ±0,1
+0,1
0
3.5
2.8
27.8
4.5
27.8
11.5
±0,2
±0.1
4.5
17.15
22.2
Ø 1.75 ±0,1
3.5
22.2
2
4
1
3.1
3.9
10.3 ±0.1 2.8
3.1
15.9
20.2
2.92
5,8
10.3 ±0.1 2.8
15.9
XG
XG
Characteristics ■ wide range of forces and ratings
■ long mechanical and electrical life
■ solder, faston, PCB and screw terminals
■ compliant to IEC 60335-1, 4. ed.
Rating 250 VAC, 26 A max.
Dimensions (mm)27,8 × 15,9 × 10,3
Actuator ■ plunger
■ plain levers
■ roller levers
■ simulated roller levers
Miniature
Approvals ENEC, UL, cUL, CSA
Preferred Range
Operating pos.
Terminal
Circuit
Actuator
Contacts
(mm)
(in)
Electrical rating
ENEC
UL/CSA
XGG2-88Z1 3,20 11,43 14,7 0,57
Faston
CO
Plunger
Ag / AgNi10
16(6) A
15 A
XGG2-88-J23Z1 1,40
5,03 14,9 0,59
Faston
CO
Plain lever
Ag / AgNi10
16(6) A
15 A
XGG2-88-J26Z1 0,91
3,27 14,5 0,57 Faston
CO
Plain lever
Ag / AgNi10
16(6) A
15 A
XGG2-88-J27Z1 0,65 2,34 13,7 0,54
Faston
CO
Plain lever
Ag / AgNi10
16(6) A
15 A
XGG2-88-S20Z1 3,20 11,43 20,2 0,79 Faston
CO
Roller lever
Ag / AgNi10
16(6) A
15 A
XGG2-88-S21Z1 1,55 5,57 20,1 0,79 Faston
CO
Roller lever
Ag / AgNi10
16(6) A
15 A
XGG3-88Z1 3,20 11,43 14,7 0,57 Solder
CO
Plunger
Ag / AgNi10
16(6) A
15 A
XGG6-88Z1 3,20 11,43 14,7 0,57 Faston
CO
Plunger
Ag / AgNi10
16(6) A
15 A
XGC2-88Z1 0,80 2,86 14,7 0,57
Faston
CO
Plunger
Ag / AgNi10
12(6) A
10 A
XGC2-88-J23Z1 0,35 1,26 15,0 0,59 Faston
CO
Plain lever
Ag / AgNi10
12(6) A
10 A
XGC2-88-S20Z1 0,80 2,86 20,2 0,79 Faston
CO
Roller lever
Ag / AgNi10
12(6) A
10 A
XGC6-88Z1 0,80
2,86 14,7 0,57
Faston
CO
Plunger
Ag / AgNi10
12(6) A
10 A
XGK2-88Z1 1,50 5,36 14,7 0,57 Faston
CO
Plunger
Ag / AgNi10
12(6) A
12 A
XGK2-88-J26Z1 0,43 1,55 14,7 0,57
Faston
CO
Plain lever
Ag / AgNi10
12(6) A
12 A
XGK2-88-S21Z1 0,71 2,55 20,2 0,80
Faston
CO
Roller lever
Ag / AgNi10
12(6) A
12 A
XGK3-88Z1 1,50 5,36 14,7
0,57
Solder
CO
Plunger
Ag / AgNi10
12(6) A
12 A
XGK6-88Z1 1,50 5,36 14,7 0,57
Faston
CO
Plunger
Ag / AgNi10
12(6) A
12 A
XGO2-88Z1 1,20 4,29 14,5 0,57
Faston
CO
Plunger
Ag / AgNi10
16(6) A
15 A
XGO2-88-J27Z1 0,25 0,90 13,6 0,54
Faston
CO
Plain lever
Ag / AgNi10
16(6) A
15 A
XGO2-88-S20Z1 1,20 4,29 20,1 0,79
Faston
CO
Roller lever
Ag / AgNi10
16(6) A
15 A
4,29 14,5 0,57
Faston
CO
Plunger
Ag / AgNi10
16(6) A
15 A
XGO6-88Z1 1,20 34
Saia microswitches
[email protected]
www.saia-switch.com
Miniature
Ordering Actuating Force
Reference(N)
(ozf)
XG
Specifications
Housing
Melamine-Formaldehyd. Thermosetting
Plunger
POM, PPS, MF depending on temperature/type
Mechanism
Snap-action, single pole beryllium bronze blade mechanisme with wiping contacts
Functions
Change-over, normally-closed (except XGG and XGK) or normally-open
Contacts
Fine silver (Ag), silver nickel (AgNi10), gold-plated (Au), silver cadmium oxide (AgCdO)
Terminals
Solder, faston, screw, PCB and side mounting PCB terminals. RAST 5 terminals (5,0 mm pitch)
Temperature range ºC
-40°C to +150°C
Mechanical life2 x 105 cycles minimum, 5 x 106 cycles maximum
(Actuation: sinusoidal and maximum up to 80% of the overtravel)
Protection
Enclosure IP40
Mounting
Side mounting via mounting holes
Actuators
Stainless steel
Actuating force/travel
Contact force/travel
Miniature
Circuit diagram NORMALLY
CLOSED
NORMALLY
OPEN
COMMON
XG
XGK
10.3 ±0.1 2.8
36
24
20
+0,1
5,8
15
12
10
0,1
0,2
DC in A
0,4 0,6
ohmic
10.3 ±0.1
2.8load
10.3 ±0.2
inductive load
10.3 ±0.2
±0.1x0.8
30
3.1 0
5,8
+0,1
0
48
40
2
4
3.1
XG
20.2 ±0.2
1
60
11.5
6.3 ±0.1x0.8
27.8
110
80
17.15
2.8
2.8
±0.1
22.2 ±0.1
22.2
11.5
Ø 1.75 ±0,1
17.15
4.5 ±0,2
2
4
220
150
100
27.8
3.5
200
2.92
1
0
3.5
2.92
+0,1
Maximum DC
3.1 rating
3.9
+0,1
3.1 0
XGG
±0.2
DC rating in VDC
20.2
15.9
Dimensions
15.9
1
2
4
5
10 16
L
= 10 ms
R
3.9
6.3
Recommended maximum electrical ratings
Voltage
(VAC)
Approvals Voltage
ENEC
UL
(VAC) (VAC)
Approvals
ENEC
UL
(VAC)
XGG..-88
XGA..-88
XGM..-88
XGO..-88
250
250
250
250
1.75
16 (6) Ø5E4
16 (6) 5E4
4.5 ±0,2
16 (6) 5E4
16 (6) 5E4
15 A
15 A
15 A
15 A
125/250
125/250
125/250
125/250
XGT..-86
XGD..-86
XGA..-86
XGM..-86
250
250
250
250
26 (10)
22 (6)
20 (8)
20 (8)
25E3
5E4
5E4
5E4
25A
21A
15A
15A
125/250
125/250
125/250
125/250
XGB..-88
XGC..-88
XGH..-88
XGK..-88
250
250
250
250
12 (6) 12 (6) 12 (6) 12 (6) 5E4
5E4
5E4
5E4
12 A
10 A
10 A
12 A
125/250
125/250
125/250
125/250
XGO..-86
XGA..-86
XGG..-86
XGM..-86
250
400
400
400
20 (8)
10 (6)
10 (6)
10 (6)
5E4
5E4
5E4
5E4
15A
–
–
–
125/250
–
–
–
XG....-88 400
3 (2)
5E4
XGO..-86 400
10 (6)
5E4
–
–
Saia microswitches
±0,1
[email protected]
www.saia-switch.com
35
XG
Operating Characteristics
Actuator XG
Reference
OP
±0.2
20.2
±0.2
1
XG 20.2
±0.2
XG
2)
2
4
2)
OP
FP
FP
20.2
XG13.5
1
20.2
8.2
1)2
4
±0.2
2.92 2)
Release
Force
Minimum
(N) (ozf)
XGG.. 3,211,43 0,4
XGA.. 3,211,43 0,6
XGM.. 2
7,14 0,5
XGO.. 1,2 4,29 0,1
XGK.. 1,5 Plunger
5,36 0,2
XGB.. 1,5 5,36 0,3
XGC.. 0,8 2,86 0,1
XGH.. 0,45 1,61 0,05
Plunger
XGT 3,211,43
0,6
XGD.. 1,7 6,07 0,15
2
Free
Operating
Position FP
Position OP
Maximum
(mm) (in)
(mm)
(in)
1,4315,750,62
2,1415,750,62
1,79 15,6 0,61
0,36 15,6 0,61
0,71 15,75 0,62
1,07 15,75 0,62
0,36 15,75 0,62
0,18 15,6 0,61
2,1415,750,62
0,54 15,75 0,62
Plunger
11.8
11.8
OP
11.8 11.8
FP
FP
OP
13.511
11.8 11.8 11.8 11.8 11.8
11.8
OP
FP
FPFP
OP
OP
FP FP
OP OP OP
FP
-J20 Lever
11,43 0,36 1,29 16,5 0,64
XG13.51 8.2 1)24 XGG.. 3,2 -J02
20.2 ±0.2 4 XGA.. 3,2 11,43 0,54 1,93 16,5
0,64
1
2.92 2)
XGM.. 2
7,14 0,45 1,61 16,5 0,64
1)2
Plunger
8.2
13.5
1,2 4,29 0,09 0,34 16,5 0,64
4 XGO..
±0.2 2
20.2
1
0,64
14.6
8.2 1) XGK.. 1,5 -J025,36 0,18 0,64 16,5
2)
4
2.92
1,5 Plunger
5,36 0,27 0,96 16,5 0,64
2 XGB..
1
4
0,64
8.2 1)2 XGC.. 0,8 -J022,86 0,09 0,32 16,5
13.51
XGH.. 0,45 1,61 0,04 0,14 16,5 0,64
4
1)2
1
14.6 7 8.2
2
-M02
Width of lever
mm/0,28
in – also available
with width 4 mm/0,16 in
Plunger
11.8 11.8 11.8 11.8 11.8
11.8
FP FP FP FP FP
OPOP OP OP OP
FP FP
OP OP
OP OP
FP FP
.4
14.6
2
8.2 1)4
2.4
OP
11.8 11.8 11.8 11.8 11.8
11.8
FP
OP OP OP
FP
FP
OP
FP FP FP
FPFP
OPOP
1)2
1
-L20 Lever
R
12.8
8.2 4 XGG..
2.4
2
XGA..
1
1)
R
12.8
8.2 4 XGM..
2.4
1
21)2
R
12.8
8.2 44 XGO..
2.4
11
1)
R
12.8
8.2 2 XGK..
2.4
1)1)4 XGB..
RR
12.8
8.2
12.8
8.2 2
2.24.
1
XGC..
4
4
1)2 XGH..
1
R
12.8
8.2 4
2.4
Width of lever1 7 mm/0,28
in
2
R
12.8
8.2
1)
2,6 -J029,29
2,6 -M029,29
1,65 5,89
-J02
1
3,57
1,25 -M024,46
1,25 -L02
-J024,46
0,65 2,32
1,37 -M021,32
OP
-T02
11.8
11.8 11.8 11.8 11.8 11.8
FP
OP OP OP
OP
OP
FP FP FP
FP
FP
2
OP
11.8
11.8
FP
OP
1)4 XGG..
-T20 3)Lever
3,2 11,43
R
12.8
8.2
1
2.4
XGA.. 3,2 11,43
2
-T027,14
XGM.. 2
4
1
XGO.. 1,2 4,29
XGK.. 1,5 5,36
2
1,5 -T025,36
4 XGB..
1
XGC.. 0,8 2,86
XGH.. 0,45 1,61
Width of roller 6,6 mm/0,26 in
0,350,01313,20,519
0,150,00613,20,519
0,35 0,013 13,7 0,539
0,35 0,013 13,7 0,539
0,35 0,013 13,2 0,519
0,15 0,006 13,2 0,519
0,15 0,006 13,2 0,519
0,35 0,013 13,7 0,539
0,150,00613,20,519
0,15 0,006 13,2 0,519
14
14
14,4
14,4
14
14
14
14,4
0,551
0,551
0,566
0,566
0,551
0,551
0,551
0,566
0,32
0,48
0,4
0,08
0,16
0,24
0,08
0,04
1,14
1,71
1,43
0,29
0,57
0,86
1,29
0,14
19,2
19,2
19,2
19,2
19,2
19,2
19,2
19,2
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
17,5 0,68 0,45
17,5 0,68 0,2
17,3 0,68 0,45
17,3 ± 0,70,68 ± 0,027 0,45
17,5 0,68 0,45
17,5 0,68 0,2
17,5 0,68 0,2
17,3 0,68 0,45
0,017
0,007
0,017
0,017
0,017
0,007
0,007
0,017
16,4
16,4
16,9
16,9
16,4
16,4
16,4
16,9
0,645
0,645
0,665
0,665
0,645
0,645
0,645
0,665
0,38
0,85
0,48
0,09
0,19
0,29
0,09
0,04
1,36
3,04
1,71
0,32
0,68
1,04
0,32
0,14
21,8
21,8
21,8
21,8
21,8
21,8
21,8
21,8
0,85
0,85
0,85
0,85
0,85
0,85
0,85
0,85
20,5 0,81 0,4
20,5 0,81 0,2
20,3 0,8 0,4
20,1 ± 0,60,79 ± 0,023 0,4
20,5 0,81 0,4
20,5 0,81 0,2
20,5 0,81 0,2
20,3 0,8 0,4
0,015
0,007
0,015
0,015
0,015
0,007
0,007
0,015
19,5
19,5
19,8
19,8
19,5
19,5
19,5
19,8
0,767
0,767
0,779
0,779
0,767
0,767
0,767
0,779
0,37
0,56
0,47
0,09
0,18
0,28
0,09
0,04
1,32
2
1,68
0,32
0,64
1
0,32
0,14
21,8
21,8
21,8
21,8
21,8
21,8
21,8
21,8
0,85
0,85
0,85
0,85
0,85
0,85
0,85
0,85
20,2 0,79 0,4
20,2 0,79 0,2
20,1 0,79 0,4
20,1 ± 0,70,79 ± 0,027 0,4
20,2 0,79 0,4
20,2 0,79 0,2
20,2 0,79 0,2
20,1 0,79 0,4
0,015
0,007
0,015
0,015
0,015
0,007
0,007
0,015
19,3
19,3
19,7
19,7
19,3
19,3
19,3
19,7
0,759
0,759
0,775
0,775
0,759
0,759
0,759
0,775
0,37
0,56
0,05
0,09
0,18
0,28
0,09
0,04
1,32
2
1,68
0,32
0,64
1
0,32
0,14
21,8
21,8
21,8
21,8
21,8
21,8
21,8
21,8
0,85
0,85
0,85
0,85
0,85
0,85
0,85
0,85
20,2 0,79 0,4
20,2 0,79 0,2
20,1 0,79 0,4
20,1 ± 0,70,79 ± 0,027 0,4
20,2 0,79 0,4
20,2 0,79 0,2
20,2 0,79 0,2
20,1 0,79 0,4
0,015
0,007
0,015
0,015
0,015
0,007
0,007
0,015
19,3
19,3
19,7
19,7
19,3
19,3
19,3
19,7
0,759
0,759
0,775
0,775
0,759
0,759
0,759
0,775
-S02
-T02
-L02
11,43
}
}
}
}
}
Total
travelled
position
(mm) (in)
0,015
0,007
0,015
0,015
0,015
0,007
0,007
0,015
4
22
1)
}
}
}
}
}
0,57
0,57
0,57
0,57
0,57 +0,007
0,57 –0,015
0,57
0,57
0,57
0,57
Movement
Differential
Maximum
(mm) (in)
15,1 0,59 0,4
15,1 0,59 0,2
15 0,59 0,4
15 ± 0,5 0,59 ± 0,019 0,4
15,1 0,59 0,4
15,1 0,59 0,2
15,1 0,59 0,2
15 0,59 0,4
-L02
3,2 -M02
11,43
3,2 -L02
11,43
2
7,14
-S02
-M02
1,2 4,29
1,5 5,36
-L02
1,5 5,36
0,8 -S022,86
0,45 -L021,61
R
-S20 Lever
12.8
8.2 44 XGG.. 3,2
2.4
1
3,2 11,43
1) XGA..
R
12.81
8.2 2
2.4
-S027,14
XGM.. 2
4
1)
R
12.8
8.2 2 XGO.. 1,2
1
2.4
-T024,29
4
XGK.. 1,5 5,36
1)2
1
R
12.8
8.2 4 XGB.. 1,5 -S025,36
2.4
2
1
XGC.. 0,8 -T022,86
4
1
0,45 -S021,61
1)2 XGH..
R
12.8
8.2 4
.4 roller
Width 2of
6,6 mm/0,26
in
1
1
} }
14,7
14,7
14,5
14,5
14,7 +0,2
14,7 –0,4
14,7
14,5
14,7
14,7
4
8.2 1)4
2
-M20 Lever
14.6
8.2 1) XGG..
1)4
R
12.8
8.2 2 XGA..
2.4
1
8.2 1)4
13.5
XGM..
2
1
1)4 XGO..
14.61
8.2 2
1) XGK..
R
12.8
8.2 4
2.4
1
22 XGB..
4
14.61
8.2 1)1)4 XGC..
R
12.8
8.2 2 XGH..
2.4
1)4
WidthR 2 of lever
mm/0,28
in
12.81 7 8.2
FP
Miniature
XG
2)
OP
FP
Plunger
2.92
2.92
2.92
Actuating
Force
Maximum
(N) (ozf)
1)
Lever distance 8,2 (0,32) for lever position –.20, lever position (-J20, L20, S20, M20)
Lever distance 14,0 (0,55) for lever position –.40, lever position (-J40, L40, S40, M40)
2)
2,65 mm for switch type XGH, XGO, XGM
3)
For high temperature T125°C/T 150°C (ENEC, UL)
36
Saia microswitches
[email protected]
www.saia-switch.com
XG
Ordering Reference
Basic type XGG..
XGA..
XGM..
XGO.. XGK..
XGB..
XGC..
XGH..
XGD..
XGT..
3,2 N
3,2 N
2,0 N
1,2 N
1,5 N
1,5 N
0,8 N
0,45 N
1,7 N
3,2 N
11,43 ozf
11,43 ozf
7,14 ozf
4,29 ozf
5,36 ozf
5,36 ozf
2,86 ozf
1,61 ozf
6,07 ozf
11,43 ozf
Circuit
4
5
No symbol, change-over (CO)
Normally closed (NC)
Normally open (NO)
Terminals2
3
4
5
6
7
8
9
10
11
12
13
14
15
19
Faston
Solder
Faston
Faston
Faston
Screw
Faston
Faston
Faston
Faston
Short solder
Print bent (lid)
Print bent (base)
Rast 5
Short solder
Example: XGG
4
2
A
-88
J20
Z1
Miniature
6,3 × 0,8
1,7 × 3,2
1× 2,8 × 0,5 DIN
1× 2,8 × 0,5 4,8 × 0,5
1× 2,8 × 0,8 DIN
1× 2,8 × 0,8
4,8 × 0,8
2× 2,8 × 0,8
∅ 2,3
6,3 × 0,8
∅ 1,7
Other types of terminals are available on request
Version
ENEC
No symbol, T85
A
T85
W
T150
AW
T150
B
T85
V
T125
AV
T125
C
T85
Number of operations at rated load
UL
Europe UL
T90
50,000
6,000
T90
50,000 100,000
T150
50,000
6,000
T150
50,000
100,000
T90
10,000
6,000
T130
50,000
6,000
T130
50,000
100,000
T90
25,000
6,000
Contacts -88
-81
-86
Ag / AgNi10
Gold-plated 4 µm (Au) on Ag
Ag / Ag CdO
Actuators
J201)J402)
J221)J422)
J231)J432)
J271)J472)
M201)M402)
L201)L402)
L211)L412)
S201)S402)
T201)T402)
No symbol, plunger
Plain lever
13,5 mm
Plain lever
24,0 mm
Plain lever
27,8 mm
Plain lever
60,0 mm
Plain lever formed
14,7 mm
Cam follower
12,8 mm
Cam follower
26,2 mm
Roller lever
12,8 mm
Roller lever, 150°C version 12,8 mm
Other actuators available on request
1)
Lever distance 8,2 (0,32) for lever position –.20, lever position (-J20, L20, S20, M20)
2)
Lever distance 14,0 (0,55) for lever position –.40, lever position (-J40, L40, S40, M40)
Approvals
Z1
Saia microswitches
No symbol, ENEC
UL, CSA
[email protected]
www.saia-switch.com
37
Thermoplastic
Microswitches
Circuit diagram
NORMALLY
CLOSED
NORMALLY
OPEN
COMMON
X3
Dimension
20.2 ±0.2
+0,1
3.1 0
3.1 +0.1
0
3.9
15.9
10.3 ±0.1
5.8
3.1 +0.1
0
X3
10.3 ±0.2
+0,1
10.3 ±0.2
3.1 0
6.3 ±0.1 x0.8
20.2 ±0.2
3.9
2.8
2
4
4.5 ±0.2
1
2.8
1.75 ±0,1
6.3 ±0.1 x0.8
11.5
2.8
27.8
17.15
27.8
11.5
4.5 ±0.2
17.15
22.2 ±0.1
1.75 ±0,1
3.5
22.2 ±0.1
2
4
1
3.5
2.8
2.8
5.8
10.3 ±0.1
15.9
2.8
X3
X3
Characteristics ■ 8 mm creepage and clearance distance to the actuator
■ long mechanical and electrical life
■ solder, faston and PCB terminal
■ compliant to glow wire requirements IEC 60335-1, 4. ed.
Rating 250 VAC, 21 A max.
Dimensions (mm)27,8 × 15,9 × 10,3
Actuator ■ plunger
■ straight lever
■ simulated roller levers
■ roller levers
Approvals UL, cUL, CSA, ENEC, CQC
Preferred Range
Miniature
Ordering Actuating Force
Reference(N)
(ozf)
Operating pos.
Terminal
Circuit
Actuator
Contacts
(mm)
(Inch)
Electrical rating
ENEC
UL/CSA
X3M302N2KA 1,60 5,55
14,7 0,58
Faston
CO
Plunger
Ag/AgNi10
16 (6) A
20,5 A
X3M302N2NAJ32 0,88
3,15
15,6
0,59
Faston
CO
Plain lever
Ag/AgNi10
16 (6) A
20,5 A
X3M302N2NAJ62 0,57 2,05
14,8 0,58
Faston
CO
Plain lever
Ag/AgNi10
16 (6) A
20,5 A
X3M302N2NAT02 2,00 7,19
20,2 0,80
Faston
CO
Roller lever
Ag/AgNi10
16 (6) A
20,5 A
X3M303N2KA 1,60 5,73
14,7 0,58
Solder
CO
Plunger
Ag/AgNi10
16 (6) A
20,5 A
X3M306N2KA 1,60 5,73
14,7 0,58
Faston
CO
Plunger
Ag/AgNi10
16 (6) A
20,5 A
X3C302N2LB 0,80 2,88
14,7 0,58
Faston
CO
Plunger
Ag/AgNi10
10 (3) A
12
A
X3C302N2LBJ32 0,35 1,26
15,0
0,59
Faston
CO
Plain lever
Ag/AgNi10
10 (3) A
12
A
X3C303N2LB 0,80 2,88
14,7 0,58
Solder
CO
Plunger
Ag/AgNi10
10 (3) A
12
A
X3C306N2LB 0,80 2,88
14,7 0,58
Faston
CO
Plunger
Ag/AgNi10
10 (3) A
12
A
X3L302N6DD 1,50 5,40
14,7 0,58
Faston
CO
Plunger
Ag/AgCdO
21 (8) A
21
A
X3L303N6DD 1,50 5,40
14,7 0,58
Solder
CO
Plunger
Ag/AgCdO
21 (8) A
21
A
Saia microswitches
[email protected]
www.saia-switch.com
Miniature
39
X3
Specifications
Housing
Plunger
Mechanism
Contact carrier
Contacts
Terminals
Temperature range ºC
Mechanical life
Protection
Mounting
Actuators
Thermoplastic
Thermoplastic
Snap-action, single pole beryllium bronze blade mechanism with wiping contacts
Brass
Fine silver (Ag), silver nickel (AgNi10), gold-plated (Au), silver cadmium oxide (AgCd0)
Solder, Faston and RAST 5 terminals
Between –40°C and +125°C
minimum cycles X3L: 105/ X3M: 106/ X3C: 2 x 106
(Actuation: sinusoidal and maximum up to 80% of the overtravel)
EncIosure IP40
Side mounting via mounting holes
Stainless steel (lever)
Actuating force/travel
Circuit diagram
Contact force/travel
NORMALLY
CLOSED
COMMON
X3
20.2 ±0.2
3.9
+0,1
200
3.5
3.1 0
150
15.9
10.3 ±0.1
Direct voltage in VDC
X3C
15
10
12
0,1
5.8
0,4 0,6
1
2
4
6
10 16
ohmic load
L
inductive load = 10 ms
10.3 ±0.1 R2.8
15.9
10.3 ±0.2
6.3 ±0.1 x0.8
0,2
DC in A
+0,1
3.1 0
5.8
24
20
2
4
3.1 +0.1
0
20.2 ±0.2
36
30
10.3 ±0.2
27.8
1
48
40
11.5
6.3 ±0.1 x0.8
2.8
60
17.15
2.8
22.2 ±0.1
11.5
22.2 ±0.1
17.15
27.8
3.5
1.75 ±0,1
1
4.5 ±0.2
2
4
110
80
Recommended maximum electrical ratings
Voltage
(VAC)
Resistive load
(A)
Motor load
(A)
1.75 ±0,1
Approvals ENEC
(A) (VAC)
X3M 250 16 6
16 (6)
5E4 250
4.5 ±0.2
X3C 250 10 3
10 (3)
5E4 250
X3L 250 21 8
21 (8) 1E4 250
Approvals UL
(A)
(VAC)
Motor load
20,5
20,5
12
12
21 21
11⁄2 HP
1
⁄2 HP
1
⁄3 HP
1
⁄6 HP
2 HP
1 HP
250
125
250
125
250
125
Current breaking capacities in the tables refer to Ag/AgNi10 contacts with the exception of X3L Ag/AgCd0
40
Saia microswitches
[email protected]
www.saia-switch.com
X3
2.8
100
2.8
2.8
+0.1
3.1
2200
Maximum DC rating
X3M
Dimensions
3.9
Miniature
NORMALLY
OPEN
X3
Operating Characteristics
Actuating
Release
Free FP
Operating OP
ActuatorX3
ReferenceForce
Force
Position
Position
X3
Maximum
Minimum
Maximum
(N)(ozf)
(N)(ozf)(mm)(in)(mm) (in)
X3
Plunger
2.8
2.8
1
±0.2
20.2
13.5
13.5 8.2
8.2
13.5
1
11.8
11.8
11.8
FP
FP
OP
OP
OP
1
±0.2
20.2
1
OP
FP
20.2
X3
OP
OP
OP
FP
FP
FP
FP
FP
X3
±0.2
2.8
OP
J02 Lever
±0.2
20.2
20.2 ±0.2
2.8
2.8
11
1
13.5
8.2
2
2
4
4
2
4
} }
X3C
0,80 2,88 0,0500,179 15,75 0,62014,7
X3M
1,60 5,76 0,2000,719 15,75 0,62014,7
X3L
Plunger
Plunger
1,50 5,40 0,1500,540 15,75 0,62014,7
0,58
Movement
Full
Differential
overtravel
Maximum
Position
(mm)
(in)(mm)
(in)
0,250,00913,2 0,519
+0,008
+0,2
0,58 –0,016 0,250,00913,2 0,519
–0,4
0,58
0,250,00913,2 0,519
Plunger
X3C ..
0,80 2,88 0,045 0,162 16,50 0,649 15,1 ± 0,5 0,59 ± 0,019 0,35 0,014 14,0 0,550
2
4
X3M ..Plunger2,00 7,19 0,180 0,647 16,50 0,649 15,1 ± 0,5 0,59 ± 0,019 0,35 0,014 14,0 0,550
22
2
44
4
J02 1,90
X3L .. Plunger
6,83 0,140 0,500 16,50 0,649 15,1 ± 0,5 0,59 ± 0,019 0,35 0,014 14,0 0,550
J02
8.2 2
J02
OP
OP
OP
14.6
1
8.2
11.8
8.2
11.8
11.8
11.8
OP
OP
FP
FP
FP
FP
11.8
FP
14.6
RR
22..44
1
1
1
2
4
2
2
24
4
4
14.6
8.2 2
12.8
1
12.8
14.6
8.2
8.2
8.2
4
X3C ..
J02
0,65 2,34 0,045 0,162 19,20 0,755 17,5 ± 0,7 0,69 ± 0,028 0,35 0,014 16,4 0,646
J02
M02
M02
1,65 5,93 0,160 0,576 19,20 0,755 17,5 ± 0,7 0,69 ± 0,028 0,35 0,014 16,4 0,646
X3M ..
X3L .. M02 1,55 5,58 0,140 0,500 19,20 0,755 17,5 ± 0,7 0,69 ± 0,028 0,35 0,014 16,4 0,646
FP
FP
FP
OP
OP
OP
FP
OP
11.8
11.8
11.8
R
12.8
12.8
1
12.8
4
8.2
8.2
8.2
11.8
RR
R 22..4
2.4
4
2.4
4
8.2 4
1
2
11.8
R
12.8
2.
4
2
2
24
1
12.8
1
11.8
11.8
11.8
FP
OP
FP
L02 Lever
OP
11.8
M02
12.8 8.2 2
R
4
2.4of lever 7,0 mm/0,28
Width
in 1
1
M02
L02 0,80
X3C .. L02
2,88 0,045 0,162 21,80 0,858 20,5 ± 0,6 0,81 ± 0,024 0,35 0,014 19,5 0,768
X3M ..L02 2,00 7,19 0,190 0,683 21,80 0,858 20,5 ± 0,6 0,81 ± 0,024 0,35 0,014 19,5 0,768
X3L ..
8.2 2
1,90 6,83 0,140 0,500 21,80 0,858 20,5 ± 0,6 0,81 ± 0,024 0,35 0,014 19,5 0,768
L02
4
11.8
2
L02
2
T02
24
4
Width of lever
inT02
1 7,0
4
12.8
8.2 mm/0,28
1
R
1
2.
4
2
T02 Lever
X3C .. T02 0,80 2,88 0,045 0,162 21,80 0,858 20,2 ± 0,7 0,79 ± 0,028 0,35 0,014 19,3 0,760
12.8 8.2 4
11.8
4
11.8
FP
1
2.
OP
FP
OP
R
1
1
2
4
2
4
X3M ..
2,00 7,19 0,190 0,683 21,80 0,858 20,2 ± 0,7 0,79 ± 0,028 0,35 0,014 19,3 0,760
T02
X3L ..
1,90 6,83 0,140 0,500 21,80 0,858 20,2 ± 0,7 0,79 ± 0,028 0,35 0,014 19,3 0,760
T02
Width of roller 6,6 mm/0,26 in Saia microswitches
[email protected]
www.saia-switch.com
41
Miniature
FP
FP
M02 Lever
OP
OP
FP
4
1
Width of lever
7,0
mm/0,28
in – also available with width 4 mm/0,16 in
13.5
8.2
14.6
8.2
X3
Ordering Reference
Basic type X3
Operating force M L C Standard force 1
Standard force 2
Low force
Circuit diagram 3
4
5
Change-over (CO)
Normally closed (NC)
Normally open (NO)
Terminals
Plug terminal 6,3 × 0,8 mm
13
Solder terminal
14
15
Plug terminal 4,8 × 0,5 mm
Plug terminal 4,8 × 0,8 mm
Solder terminal, short
02
03
06
10
12
BodyN
Contacts materials2
6
8
Miniature
Microswitch according to DIN 41635, Design A
M
3
02
K
2
A
A
J0
2
PCB-terminal, Formed to lid
PCB-terminal, Formed to base
Plug terminal RAST 5 6,3 × 0,8 mm
Silver/AgNi10
AgCd0
Gold plated
6 A, 125/250 VAC
⁄3 HP, 250 VAC, 1⁄6 HP, 125 VAC
No approvals
20,5 A, 125/250 VAC
1½ HP, 250 VAC, ½ HP, 125 VAC
¼ HP, 250 VDC, ½ HP, 125 VDC
12 A, 125/250 VAC
1
⁄3 HP, 250 VAC, 1⁄6 HP, 125 VAC
¼ A, 250 VDC, ½ A, 125 VDC
6 A, 125/250 VAC
1
⁄3 HP, 250 VAC, 1⁄6 HP, 125 VAC
¼ A, 250 VDC, ½ A, 125 VDC
1
Miniature
42
Example: X3
PA66GF25
UL/C-UL ratings A
20,5 A, 125/250 VAC M
15 A, 125/250 VAC, 100’000 cy.
1½ HP, 250 VAC, ½ HP, 125 VAC N
D
21 A, 125/250 VAC P
2 HP, 250 VAC, 1 HP, 125 VAC E
21 A, 125/250 VAC 15 A, 125/250 VAC, 100’000 cy.
Q
2 HP, 250 VAC, 1 HP, 125 VAC
K
20,5 A, 125/250 VAC 1½ HP, 250 VAC, ½ HP, 125 VAC R
L
12 A, 125/250 VAC 1
⁄3 HP, 250 VAC, 1/6 HP, 125 VAC EN/IEC ratings A
16 (6) A, 250 V~ 5E4 T125 µ approved
B
10 (3) A, 250 V~ 5E4 T125 µ approved
C
6 (3) A, 250 V~ 5E4 T125 µ approved
D
21 (8) A, 250 V~ 1E4 T105 µ approved
M
no approvals
Type of actuator
No symbol, without lever
J0 to J9 Straight lever (width 7 mm)
L0 to L9 Simulated roller lever
M0 to M9 Customer specified lever (KV)
P0 to P9 Straight lever (width 4 mm)
T0 to T9 Roller lever
Other actuators and lengths available
Actuator position
2
4
No symbol, without lever
Rear lever
Front lever
Saia microswitches
[email protected]
www.saia-switch.com
3 mm contact gap
Microswitch
Circuit diagram
2
NORMALLY
CLOSED
4
NORMALLY
OPEN
1
COMMON
Dimension
14.00
[0.55]
5.35
2.75
[0.11]
NC
3,5 ± 0,1
3,2
15.93
13.08
10.29
15.88
.79
NO
COM
22.22
2
28.83
41.28
10.40
[0.41]
Ø3.10+0.1
[0.12]
22.20±0.1
[0.87]
MAX 28.0
[1.09]
4
MAX 11.40
[0.45]
B340-A
0.80±0.15
[0.03]
2.80
[0.11]
1
REF 2.90
[0.11]
10.30±0.1
[0.41]
10.06
+0.15
6.30-0.10
[0.25]
Ø3.50
[0.14]
R2
MAX 13.10
[0.52]
FREE POSITION
20.49
4.00
[0.16]
Ø 3.2
8.20
[0.32]
3.05
3.10+0.1
[0.12]
2.00
[0.08]
4.57
15.90
[0.63]
20.23
340
340
Characteristics ■ wiping contacts, leaf spring mechanism
■ 3 mm contact gap
■ compliant to glow wire requirements
IEC 60335-1, 4. ed. as optional item
Rating 250 VAC, 16 A max.
Dimensions28,8 × 20,4 × 10,1
Actuator ■ plunger
■ roller lever
■ plain levers
■ simulated roller lever
■ moulded lever
Approvals ENEC, UL
Popular Products
Ordering Reference Actuating Force (N)
(ozf)
Operating pos.
(mm)
(in)
343B120350NO 4,9
+0,3
14,7 –0,6
17,50
Terminal
Contact Gap
Actuator
Contacts
(mm)
Electrical rating
ENEC
UL/CSA
+0,01
0,58 Faston
3
Plunger AgCd0 16 (3) A, 250 VAC 12 A, 125–250 VAC
–0,02
Miniature
Specifications
Glass-filled flame retardant Nylon 6,6
Glass-filled flame retardant Nylon 6,6
Snap action, single pole leaf spring mechanism
Change-over, Normally open, Normally closed
Silver
Solder, Faston and Rast 5 terminals
-10°C to +85°C
107 cycles minimum (3 mm gap 106) (impact-free actuation)
IP40 (enclosure)
Side mounting
Plunger, plain lever, roller lever
Miniature
Housing
Plunger
Mechanism
Functions
Contacts
Terminals
Temperature range
Mechanical life
Protection
Mounting
Actuators
Circuit diagram
NORMALLY
CLOSED
COMMON
NORMALLY
OPEN
44
Saia microswitches
[email protected]
www.saia-switch.com
340
Dimensions
20.23
344343
2.97
344
345
5.3
12.45
5.3
2
6.35
11.43
6.35
5.0
12.45
5.0
2
5.3
0.8
TYP
2
12.45
5.0
6.83
YP
6.83
ENEC
3 mm Wide gap 16(3) A, 250 VAC, 50 E3, T85
Saia microswitches
12.47
30.34
UL/CSA
Motor load
12 A, 125–250 VAC, T85
½ HP
[email protected]
5.0
5.0
YP
5T
2.2
12.47
30.34
0.8
TYP
1.51
Versions
YP
5T
2.2
www.saia-switch.com
2.2
5T
30.34
45
YP
Miniature
Recommended maximum electrical ratings
1.51
5.0
12.47
0.8
TYP
30.34
1.51
YP
5T
5.0
1.51
5T
0.8
TYP
0.8
TYP
2.2
12.47
5.0
6.84
6.35
6.84
6.35
5.3
12.47
30.34
30.34
6.35
2.2
12.47
12.45
5.0
5T
YP
5T
6.35
6.35
1.51
6.35
YP
5.0
6.35
6.84
5.3
2
2.97
6.35
5.3
2
11.43
6.35
6.84
6.35
4.75
0.8
0.5
348
349
6.35
12.47
6.35
30.34
2.97
4.75
0.5
2
6.84
5.3
12.45
6.35
347
348
1.51
11.43
B340-A
2.97
YP
5T
2.2
2.97
11.43
6.35
6.35
TYP
4.75
2
4.75
2.2
2.1
348
349
6.35
2.97
1.51
6.35
TYP
6.35
2
346
347
4.75
0.5
346
4,75 × 0,8
Faston
4.02
5.3
6.35
345
346
4.75
3.17
11.43
12.45
3.17
6.35
12.45TYP
6.35
4.02
Ø 2.16
6.35
TYP
6.35
TYP
ENEC0.5
Only
343
6,35 × 0,8
Faston
Ø 2.16
YP
348347
348
Rast 5
Faston
2.97
6.35 11.43
344
345
4.02
6.35
4.75
11.43
11.43
6.35
ENEC Only
T
.15
41.28
3.17
12.45
6.35
TYP
3.17
6.35
TYP
346
347
4.75
0.5
345
4,75 × 0,5
Faston
Ø 2.16
Ø 2.16
12.45
343
344
4.02
6.35
346345
4.75
ENEC Only
ENEC Only
6.35
TYP
6.35
11.43
22.22
28.83
342
Solder
342
343
34
NO
4.02
6.35
TYP
6.35
348
NC
3,5 ± 0,1
3,2
13.08
.79
12.45
TYP
342
343
347
COM
R2
10.06
346
5.35
345
ENEC Only
Ø 2.16
6.35
TYP
Ø 3.2
3.05
3.17
15.88
15.93
344
10.29
343
20.49
342
4.57
340
Operating Characteristics 34_120350
Actuator
Reference
Actuating
Release
Free
Operating
Force
Force
Position
Position
MaximumMinimumMaximum
(N)
(ozf)
(N)
(ozf) (mm)
(in)
(mm)
(in)
Movement Full
Differential
Overtravel
MaximumPosition
(mm) (in) (mm) (in)
Plunger
34_120350 4,9017,501,204,32 15,93 0,63 14,70
0,58
0,76 0,03 13,00,51
+0,3/–0,6 +0,01/–0,02
B
B
A
4.57
A
4.57
Plain lever
ZD0
4,9017,501,204,32 17,00 0,67 15,20
(Back position)
+/–0,5
0,60
+/–0,02
0,80 0,03 14,10,56
ZD1
3,6012,950,632,27 18,80 0,74 15,70
+/–0,8
B340-F B340-F
0,62
+/–0,03
1,20 0,05 13,70,54
ZD2
1,405,04 0,180,65 26,70 1,05 14,60
+/–3,0
0,57
+/–0,12
4,60 0,18 11,10,44
Roller lever
ZDS0
4,9017,501,204,32 22,20 0,87
ZDS1
3,6012,950,521,87 24,20 0,95
0,81
+/–0,03
0,83
+/–0,04
0,80 0,03 19,50,77
1,10 0,04 19,50,77
Ordering Reference
20,60
+/–0,7
21,20
+/–0,9
Basic type 34
solder
6,35 × 0,8 fast-on
4,75 × 0,5 fast-on
4,75 × 0,8 fast-on
6,35 × 0,8 Rast 5
B
No symbol, standard material
compliant to glow wire requirements IEC 60335-1, 4. ed.
Contact gap 120
Operating force 350
3 mm Circut
NO
NC
No symbol, change-over
Normally open
Normally closed
Actuator
ZD0
ZD1
ZD2
No symbol, plunger
Plain lever
22,56 mm
Plain lever
33,90 mm
Plain lever
84,43 mm
ZDS0
ZDS1
Roller lever
Roller lever
Miniature
Terminal type2
3
5 6
8
490 g
Example: 34
2
B
40
75
NO ZD0
(3 mm gap)
19,67 mm
31,70 mm
46
Saia microswitches
[email protected]
www.saia-switch.com
Table of preferred products
Snap-action Microswitches
Type
Preferred Products Preferred Products
Page
Subminiature
XCXCG3Z1 XCG8-81-J1Z1
XCG3-J1Z1XCG8-81-S1Z1
XCG3-S1Z1XCF3Z1
XCG5Z1XCF3-J1Z1
XCG5-J1Z1XCF3-S1Z1
XCG5-S1Z1XCG3-U1Z1
XCG8Z1XCG4-U1Z1
XCG8-81Z1XCG8-U1Z1
17
X4
22
X4F303N1AAX4G305N1BB
X4F305N1AAX4C303N1CC
X4G303N1BBX4C305N1CC
V4NSV4NST7UL V4NSUL
V4NST7Y1ULV4NSY1UL
V4NST7YRULV4NSYRUL
V4NCSV4NCS
V4NCSA1
V4NCSAR
27
Miniature
XG XGG2-88Z1XGK2-88Z1
XGG2-88-J23Z1XGK2-88-J26Z1
XGG2-88-J26Z1XGK2-88-S21Z1
XGG2-88-J27Z1XGK3-88Z1
XGG2-88-S20Z1XGK6-88Z1
XGG2-88-S21Z1XGO2-88Z1
XGG3-88Z1XGO2-88-J27Z1
XGG6-88Z1XGO2-88-S20Z1
XGC2-88Z1XGO6-88Z1
XGC2-88-J23Z1
XGC2-88-S20Z1
XGC6-88Z1
36
X3
X3M302N2KA
X3C302N2LB
X3M302N2KAJ32X3C302N2LBJ32
X3M302N2KAJ62X3C303N2LB
X3M302N2KAT02X3C306N2LB
X3M303N2KAX3L302N6DD
X3M306N2KAX3L303N6DD
41
340
343B120350NO
46
Saia microswitches
[email protected]
31
www.saia-switch.com
47
Headquarters
6/F, 12 Science Park East Avenue,
Hong Kong Science Park
Shatin, NT, 7^]V:^]V
Phone: +852 2663 6688
e-mail: [email protected]
Sales Offices
Asia
Europe
Americas
2WX]P
No. 1, Lane 10800, Songze
Avenue, Qingpu Industrial Zone
BWP]VWPX 201700
Phone: +86 21 5882 2880
5aP]RT
10 Bld. Louise Michel
92230 6T]]TeX[[XTab
Phone: +33 1 46 88 07 70
[email protected]
DB0
10 Progress Drive
BWT[c^], CT 06484
Phone: +1 203 447 5362
Sin Er Industrial Zone
Shajing Town, Baoan District
BWT]iWT] 518125
Phone: +86 755 2990 0001
6Ta\P]h
Weissenpferd 9
58553 7P[eTa
Phone: +49 2353 911 0
[email protected]
9P_P]
TFT Build West 5F, 3-4-10 Ariake
Kouto-Ku, C^Zh^ 135-8072
Phone: +81 355 20 0070
BX]VP_^aT
1 Maritime Square #09-01,
Harbour Front Centre
BX]VP_^aT 099253
Phone: +65 6224 7570
B^dcW:^aTP
Fine Building, 4th Floor, 701-6, BanpoDong, Seocho-Ku
BT^d[ 137-808
Phone: 82 2 518 8341
8cP[h
Via Cadamosto 3
20094 2^abXR^, Milano
Phone: +39 02 4869 21
[email protected]
BfXciTa[P]S
Bahnhofstrasse 18
3280 <dacT]
Phone: +41 26 672 71 11
[email protected]
CWT=TcWTa[P]Sb
Hanzeweg 12c
2803 MC 6^dSP
Phone: +31 1825 43 174
[email protected]
D]XcTS:X]VS^\
Unit 5, Woodstock Way,
Boldon Business Park, 1^[S^]
Tyne & Wear, NE35 9PF
Phone: +44 844 811 2130
[email protected]
801 Scholz Drive
P.O. Box 427
EP]SP[XP, OH 45377
Phone: +1 937 454 2363
1aPiX[
Av. Papa Joao Paulo I - 1174
Guarulhos, CEP 07170-350
BP^?Pd[^
Phone: +55 11 2431 5600
SAIA Switch Catalog
IPG210/ 12/E / 01
Johnson Electric
Johnson Electric Group
6/F, 12 Science Park East Avenue,
Hong Kong Science Park, Shatin, NT
Hong Kong
Tel:
+852 2663 6688
e-mail:
[email protected]
Website: www.johnsonelectric.com

Similar documents