Ducted and Duct-Free Split Systems
Transcription
Ducted and Duct-Free Split Systems
MARCH 2013 Single Split Duct-Free Systems • Wall Mounted • 9,000 to 36,000 Btu/h Ducted and Duct-Free Split Systems Single Split, Multi-Split, and SkyAir Systems Multi-Split Duct-Free Systems Connecting 2, 3, or 4 zones Single Split Ducted Systems • Wall Mounted and • Slim Duct Built-In Slim Duct Built-In • 18,000 | 24,000 | 32,000 Btu/h • 9,000 and 12,000 Btu/h SYSTEMS • Wall Mounted • 4 Way Ceiling Cassette • Ceiling Suspended • Ducted • 18,000 to 42,000 Btu/h 18 SEER Cooling Only and H/P Systems.......... Page 1 20 SEER H/P Systems............................................. Page 2 Quaternity H/P Systems........................................ Page 3 Multi-Zone......................................................... Pages 4 - 7 Super Multi Plus.............................................Pages 8 - 10 RA/MX Accessories & Tools................................Page 11 ENVi Intelligent Thermostat...............................Page 12 Condensate Pump Wiring..................................Page 13 SkyAir............................................................... Pages 14 -20 Indoor Unit Accessories......................................Page 21 Tools...........................................................................Page 21 VRV.................................................................. Pages 22 - 23 SpeediChannel............................................ Pages 24 - 27 Daikin AC (Americas), Inc. 3D Dealer Program.................................... Pages 28 - 33 1645 Wallace Drive – Suite 110 Carrollton, TX 75006 www.daikinac.com (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this price book without notice and without incurring any obligations) Standard 18 SEER KE Series Cooling Only and H/P Systems • Warranty: 6 year compressor, 2 year parts • Cooling down to 0 °F/-18 °C with optional wind baffle • Line lengths up to 65' for 09/12 and 98' for 15/18/24 • Condensing unit is precharged for up to 33 ft. of line set • Add 0.22 oz./ft. of charge for line sets longer then 33 ft. • The KE series includes the wireless remote control • Use 14/4 cable between indoor and outdoor unit Nominal Optional Optional Optional Wireless Heating Line Set Low Ambient Condensate Wired Controller Capacity Wind Baffle Pump Remote Cooling Only RKN09KEVJU FTXN09KEVJU 18 12 — 9,000 Btu/h — 1/4” X 3/8" KPW038A4 DACA-CP1-1 Included BRC944B2* RKN12KEVJU FTXN12KEVJU 18 9.9 — 12,000 Btu/h — 1/4” X 3/8" KPW038A4 DACA-CP1-1 Included BRC944B2* RKN15KEVJU FTXN15KVJU 18 12 — 15,000 Btu/h — 1/4” X 1/2" KPW937C4 DACA-CP1-1 Included BRC944B2* RKN18KEVJU FTXN18KVJU 18 12 — 18,000 Btu/h — 1/4” X 1/2" KPW937C4 DACA-CP1-1 Included BRC944B2* RKN24KEVJU FTXN24KVJU 18 8.6 — 22,000 Btu/h — 1/4” X 1/2" KPW937C4 DACA-CP1-1 Included BRC944B2* Heat pump RXN09KEVJU FTXN09KEVJU 18 12 8.5 9,000 Btu/h 10,000 Btu/h 1/4” X 3/8" KPW038A4 DACA-CP1-1 Included BRC944B2* RXN12KEVJU FTXN12KEVJU 18 9.9 8 12,000 Btu/h 12,000 Btu/h 1/4” X 3/8" KPW038A4 DACA-CP1-1 Included BRC944B2* RXN15KEVJU FTXN15KVJU 18 12 8.5 15,000 Btu/h 18,000 Btu/h 1/4” X 1/2" KPW937C4 DACA-CP1-1 Included BRC944B2* RXN18KEVJU FTXN18KVJU 18 12 8.5 18,000 Btu/h 21,600 Btu/h 1/4” X 1/2" KPW937C4 DACA-CP1-1 Included BRC944B2* RXN24KEVJU FTXN24KVJU 18 8.6 8.5 22,000 Btu/h 24,000 Btu/h 1/4” X 1/2" KPW937C4 DACA-CP1-1 Included BRC944B2* *BRC944B2 wired remote requires 10' or 26' wired remote control cable. KRP980B1 interface adaptor is also required when BRC944B2 is used with FTXN09 and 12 Outdoor Unit Indoor Unit SEER EER HSPF Nominal Cooling Capacity BRC944B2 DACA-WB-1 GT1426SSF 1 KE Series Options Wired remote controller Daikin (controller only) Wall bracket for outdoor unit Daikin Snow Stand Premium High Efficiency 20 SEER RX-L Series H/P System • Warranty: 7 year compressor, 5 year parts • Cooling down to 0 °F/-18 °C with optional wind baffle • Condensing unit is precharged for up to 33 ft. of line set • Use 14/4 cable between indoor and outdoor unit • The L series includes the wireless remote control • Line lengths of 65' for 09/12 and 98' for 15/18/24 • 0.22 oz./ft. charge for line sets longer then 33 ft. Outdoor Unit Indoor Unit SEER EER HSPF Nominal Cooling Capacity 15.3 12.5 9,000 Btu/h 12.8 12.5 12,000 Btu/h 14.4 11.6 15,000 Btu/h 12.7 11 18,000 Btu/h Nominal Optional Heating Line Set Low Ambient Capacity Wind Baffle Wall Mount 12,000 Btu/h 1/4" x 3/8" KPW937C4 14,400 Btu/h 1/4" x 3/8" KPW937C4 18,000 Btu/h 1/4" x 1/2" KPW945A4 21,600 Btu/h 1/4" x 1/2" KPW945A4 RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU FTXS09LVJU FTXS12LVJU FTXS15LVJU FTXS18LVJU 24.5 23.0 20.6 20.3 RXS24LVJU FTXS24LVJU 20.0 12.5 10.6 21,500 Btu/h 25,400 Btu/h 1/4" x 5/8" Slim Duct RXS09LVJU FDXS09LVJU 15.1 11.2 10.3 8,500 Btu/h 10,000 Btu/h 1/4" x 3/8" RXS12LVJU FDXS12LVJU 15.5 9.1 10.4 11,500 Btu/h 11,500 Btu/h 1/4" x 3/8" *BRC944B2 wired remote requires 10' or 26' wired remote control cable. BRC944B2 DACA-WB-1 GT1426SSF Optional Wireless Condensate Controller Pump Optional Wired Remote DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 Included Included Included Included BRC944B2* BRC944B2* BRC944B2* BRC944B2* KPW945A4 DACA-CP1-1 Included BRC944B2* KPW937C4 KPW937C4 DACA-CP1-1 DACA-CP1-1 Included Included BRC944B2* BRC944B2* RX-L Series Options Wired remote controller Daikin (controller only) Wall bracket for outdoor unit Daikin Snow Stand 2 Industry First! Quaternity up to 26 Seer H/P System Heating, cooling, dehumidification and air purification system • Warranty: 7 year compressor, 5 year parts • Dedicated dehumidification control • Cooling down to 14 °F/-10 °C, no low ambient option • Condensing unit is precharged for up to 33 ft. of line set • The Quaternity includes the wireless remote control • Flash stream air purifier • Line lengths of up to 33' maximum • Use 14/4 cable between indoor and outdoor unit Nominal Cooling Capacity RXG09HVJU FTXG09HVJU 26.1 15.8 11 9,000 Btu/h RXG12HVJU FTXG12HVJU 24.2 14 10.55 12,000 Btu/h RXG15HVJU FTXG15HVJU 21.0 12.9 10 15,000 Btu/h *BRC944B2 wired remote requires 10’ or 25’ wired remote control cable. Outdoor Unit Indoor Unit SEER EER HSPF BRC944B2 DACA-WB-1 GT1426SSF 3 Nominal Heating Capacity 12,000 Btu/h 16,000 Btu/h 18,000 Btu/h Optional Air Optional Wireless Direction Condensate Controller Grill Pump 1/4" x 3/8" KPW937C4 DACA-CP1-1 Included 1/4" x 3/8" KPW937C4 DACA-CP1-1 Included 1/4" x 3/8" KPW937C4 DACA-CP1-1 Included Line Set RX-G Series Options Wired remote controller Daikin (controller only) Wall bracket for outdoor unit Daikin Snow Stand Optional Wired Remote BRC944B2 BRC944B2 BRC944B2 RA/MXS Multi Zone - 2, 3, and 4 Zone • Warranty: 7 year compressor, 5 year parts • Cooling down to 14 °F/-10 °C, no low ambient option • Additional charge of 0.22 oz./ft. required for longer pipe lengths • Use 14/4 cable between indoor and outdoor units • The MXS series includes the wireless remote control • Outdoor Unit is precharged for up to 98' for 2MXS and 132' for 3MXS and 4MXS • Maximum combined line length of 164' for 2MXS and 230' for 3MXS, 4 MXS Outdoor Maximum Nominal Unit Maximum Indoor Unit Pipe Cooling precharged Ext Static Length Capacity for 2MXS18GVJU — 164' 98' — 18,000 btu/hr 3MXS24JVJU — 131.6' 132' 24,000 btu/hr 4MXS32GVJU — 131.6' 132' — 30,600 btu/hr Wall Mount — CTXS07LVJU — — — 7,000 Btu/h — CTXS09HVJU — — — 9,000 Btu/h — CTXS12HVJU — — — 12,000 Btu/h — FTXS15LVJU — — — 15,000 Btu/h — FTXS18LVJU — — — 18,000 Btu/h — FTXS15LVJU — — — 15,000 Btu/h — FTXS18LVJU — — — 18,000 Btu/h Slim Duct — FDXS09LVJU — — 0.12 8,500 Btu/h — FDXS12LVJU — — 0.12 11,500 Btu/h — CDXS15LVJU — — 0.16 — — CDXS18LVJU — — 0.16 — *BRC944B2 wired remote requires 10' or 26' wired remote control cable. Outdoor Unit BRC944B2 DACA-WB-1 GT1426SSF Nominal Heating Capacity Line Set Optional Condensate Pump Wireless Controller Included Optional Wired Remote 8,500 btu/hr 10,000 btu/hr 11,500 btu/hr 18,000 btu/hr 21,600 btu/hr 18,000 btu/hr 21,600 btu/hr 1/4" x 3/8" 1/4" x 3/8" 1/4" x 3/8" 1/4" x 1/2" 1/4" x 1/2" 1/4" x 1/2" 1/4" x 1/2" DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 Included Included Included Included Included Included Included BRC944B2* BRC944B2* BRC944B2* BRC944B2* BRC944B2* BRC944B2* BRC944B2* 10,000 btu/hr 11,500 Btu/h — — 1/4" x 3/8" 1/4" x 3/8" 1/4" x 1/2" 1/4" x 1/2" DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 Included Included Included Included BRC944B2* BRC944B2* BRC944B2* BRC944B2* 22,000 btu/hr 30,000 btu/hr 32,000 btu/hr RX-L Series Options Wired remote controller Daikin (coontroller only) Wall bracket for outdoor unit Daikin Snow Stand FFQ will also work with the MXS. 4 RA/MXS Multi Zone - 2, 3, and 4 Zone Outdoor Unit 2MXS18GVJU Outdoor Unit 3MXS24JVJU 5 Indoor Unit Combination 07 09 07+07 07+09 09+09 Indoor Unit Combination 07 07+07+07 09 07+07+09 12 07+07+12 15 07+07+15 18 07+07+18 07+07 07+09+09 07+09 07+09+12 07+12 07+09+15 07+15 07+09+18 07+18 07+12+12 09+09 07+12+15 09+12 07+12+18 09+15 07+15+15 09+18 09+09+12 12+12 09+09+12 12+15 09+09+15 12+18 09+09+18 15+15 09+12+12 15+18 09+12+15 18+18 09+12+18 09+15+15 12+12+12 12+12+15 Outdoor Unit 4MXS32GVJU 07 09 12 15 18 07+07 07+09 07+12 07+15 07+18 09+09 09+12 09+15 09+18 12+12 12+15 12+18 15+15 15+18 18+18 Indoor Unit Combination 07+07+07 07+07+09 07+07+12 07+07+15 07+07+18 07+09+09 07+09+12 07+09+15 07+09+18 07+12+12 07+12+15 07+12+18 07+15+15 07+15+18 07+18+18 09+09+09 09+09+12 09+09+15 09+09+18 09+12+12 09+12+15 09+12+18 09+15+15 09+15+18 09+18+18 12+12+12 12+12+15 12+12+18 12+15+15 12+15+18 07+07+07+07 07+07+07+09 07+07+07+12 07+07+07+15 07+07+07+18 07+07+09+09 07+07+09+12 07+07+09+15 07+07+09+18 07+07+12+12 07+07+12+15 07+07+12+18 07+09+09+09 07+09+09+12 07+09+09+12 07+09+09+18 07+09+12+12 07+09+12+15 07+12+12+12 09+09+09+09 09+09+09+12 09+09+09+15 09+09+09+18 09+09+12+12 09+09+12+15 09+12+12+12 RA/MXS Multi Zone - 2, 3, and 4 Zone System 2MXS18GVJU 3MXS24GVJU 4MXS32GVJU Certified Efficiency Performance Values Nominal Cooling Nominal Heating EER Capacity Capacity Combined With SEER Btu/h 95˚ F Btu/h Non ducted indoor unit** 18,000 12.6 19.5 22,000 Ducted indoor unit 16,000 9.0 13.0 22,000 Mixed ducted and non ducted indoor unit 17,000 10.8 16.3 22,000 Non ducted indoor unit** 24,000 12.5 16.6 30,000 Ducted indoor unit 23,400 9.7 16.6 29,000 Mixed ducted and non ducted indoor unit 23,600 11.1 14.8 29,400 Non ducted indoor unit 30,600 10.3 17.2 32,000 Ducted indoor unit 29,000 8.4 13.3 30,400 Mixed ducted and non ducted indoor unit 29,800 9.4 15.3 31,200 Low Heating Capacity Btu/h 13,500 13,100 13,300 13,500 13,100 13,300 22,200 21,000 21,600 HSPF 9.2 7.7 8.5 9.0 7.7 8.4 9.3 7.9 8.6 6 7 Super Multi Plus RMXS48LVJU The new Super Multi Plus Split System provides versatility in a space-saving design. Indoor units come in a variety of styles including wall mounted units sophisticated in appearance, slim duct units hidden in application, or 2' x 2' cassettes compact with customizable comfort. With the ability to connect up to 8 indoor units to a single outdoor unit, these intelligent systems offer design flexibility with individual zone control. • Ability to connect up to 8 indoor units to a single outdoor unit with branch port boxes • Connect indoor unit capacities up to 130% (62,000 Btu/h) of outdoor unit • A wide variety of indoor unit styles including wall mounted, slim duct, and 2' x 2' ceiling cassettes in capacity ranges between 7,000 Btu/h to 24,000 Btu/h • Individual temperature control with standard wireless or optional wired controls • Compatibility with the new Daikin ENVi web enabled thermostat 8 Super Multi Plus - Design Flexibility The new Super Multi Plus Split System can be combined with a variety of ducted and ductless models with a total of 15 indoor unit variations. Indoor Unit Availability Capacity Indoor Type Wall Mount Slim Duct 2' x 2' Cassette 7 MBH • 9 MBH • • • 12 MBH • • • 15 MBH • • • 18 MBH • • • 24 MBH • • CTXS_H, CTXS_LV, FTXS_LV Wall Mounted Unit • Blends with any décor with it’s leek and sophisticated design • Enhanced indoor air quality with the titanium apatite photocatalytic air purification filter which absorbs microscopic particles and decomposes odors • Increased energy savings with the intelligent eye function which reduces operation in unoccupied spaces FDXS_LV, CDXS_LV Slim Duct • Maximized floor and wall space with it’s compact and concealed design • Undisturbed comfort with low operating sound levels • Cleaner air with the removal or airborne dust particles by the standard mold proof air filter FFQ_LV 2’ X 2’ Ceiling Cassette • Enhanced comfort with uniform airflow and temperature distribution • Draught free protection with horizontal air discharge • Simply installation with an easy-to-fit decoration panel that blends with any interior design • Easy maintenance with an easy-to-clean grille and washable long life filter BPMKS Branch Provider Unit • Varies the refrigerant volume to meet the cooling or heating requirements of a room. • Operate rooms individually with zone on/off controls • Simple installation with flare nut connections REFNET joint • Reduces the amount of work involved in installation and increases the reliability of the system. 9 Super Multi Plus - Specifications RMXS Technical Specifications Indoor Unit — BPMKS048A2U BPMKS048A3U Outdoor Unit RMXS48LVJU — — Btu/h 48,000 / 54,000 — — SEER Min. 17.1 — — HSPF Min 10.0 — — Model Name Nominal Capacity (Cooling / Heating) Power Supply 208/230V - 1Ø - 60Hz Powered from Outdoor Unit Minimum Circuit Amps A 27.0 0.048 0.048 Maximum Overcurrent Protection A 30.0 — — Sound Pressure - (Cooling/Heating) dB(A) 56/58 32/32 32/32 50 - 130% Max. 48,000 Btu/h Max. 62,000 Btu/h Number of Connectable Indoor Units 2 to 8 1 to 2 1 to 3 Number of Connectable BP Units 1 to 3 — — Connection Ratio (Max Capacity for BPMKS Boxes) Total System Piping Length ft. (m) 440 (135) — — Max. Piping Length(OU to BP Box) ft. (m) 180.4 (55) — — Max. Piping Length(IU to BP Box) ft. (m) 49.2 (15) — — Total Piping Length (OU to BP Box) ft. (m) 180.4 (55) — — Total Piping Length (BP to IU) ft. (m) 262.5 (80) — — Max. Piping Height (OU to IU) ft. (m) 98.4 (30) — — Max. Piping Height (IU to BP Box) ft. (m) 98.4 (30) — — Max. Piping Height (BP to BP Box) ft. (m) 49.2 (15) — — KHRP26A22T — — Piping Connection Kit Operating Range - Cooling °F DB 23 - 115 — — Operating Range - Heating °F DB 5 - 75 — — Dimensions (H x W x D) in. 52-15/16 x 35-7/16 x 12-5/8 Net Weight lbs. 283.0 7-3/32 × 11-9/16 × 13-12/16 18.7 19.8 10 RA/MX Accessories & Tools Optional Controls Accessories Sky Air Wired remote controller less cable Wired remote controller 10 ft. cable Wired remote controller 26 ft. cable Loss prevention chain for wireless remote controller 14/4 Solid THHN mini-split power cable 250 ft. roll Intelligent Touch Controller (Requires commissioning) RA Interface adapter for DIII-Net use Pad condenser plastic 16" x 36" Ultralight Diversitech Part Number BRC944B2 BRCW901AC03 BRCW901AC08 KKF917A4 M84474 DCS601C71 KRP928BB2S U1636-3 Tools * Part Number Service port adaptor 5/16 valve to 1/4 hose 19173 Torque wrench 1/4” DACA-TQW1/4-1 Torque wrench 3/8” DACA-TQW3/8-1 Torque wrench 1/2” DACA-TQW1/2-1 Torque wrench 5/8” DACA-TQW5/8-1 Torque wrench 3/4” DACA-TQW3/4-1 R410A flaring tool 60295 Flare size gauge DACA-FSG-1 Deburring tool heavy duty 60163 Service tool kit; (includes gauge manifold with 5/16 hoses, flaring gauge, DACA-99STK-1 tube cutter, deburring tool and R410A flaring tool) * Daikin recommends the use of flare gauge, R410 flaring tool, deburring tool and pre-set torque wrenches on every installation 11 12 Condensate Pump Wiring Daikin AC P/N DACA-CP1-1 (Mini Aqua) DACA-CP2-1 (Maxi Orange) 13 Description • Power supply 230 VAC (+/- 10%) 0.11A, 16W 60Hz • Indoor unit capacities up to 24 MBH • Pump capacity 3.7 GPH @ 0 head, 0.8 GPH @ 26 ft. head • Maximum recommended head of 20 ft. • Mounts inside evaporator casing or inside the line set cover • Sound level 21 dB (A) @ 3 ft. • ETL Listed • Ideal for FXAQ_MVJU, FTXS_DVJU/HVJU & CTXS_DVJU/HVJU indoor evaporators • Power supply 230 VAC (+/- 10%) 0.15A, 21W 60Hz • Indoor unit capacities up to 60 MBH • Pump capacity 10 GPH @ 0 head, 3.8 GPH @ 65 ft. head • Maximum recommended head of 65 ft. • Sound level 35 dB (A) @ 3 ft. • ETL Listed Applicable Indoor Units for DACA-CP1-1 CTXS09-12GVJU CTSXD9-12HVJU FTXS09-24DVJU FTXS09-24HVJU FDXS09-12DVJU FTXG09-15HVJU FXAQ07-24MVJU Family RA Series RA Series RA Series RA Series RA Series RA Series VRV Series FXLQ12-24MVJU FXNQ12-24MVJU FXHQ12-24MVJU FAQ18-24PVJU FHQ244MVJU FHQ18-24PVJU VRV Series VRV Series VRV Series SkyAir Series SkyAir Series SkyAir Series SkyAir Single Zone Wall Mount RZQ18/24 Cooling & H/P System • Warranty: 7 year compressor, 5 year parts • Maximum pipe length 164' • 18/2 non-shielded control wire between indoor and outdoor unit • Cooling down to 0 °F/-18 °C with optional wand baffle • Factory charged for outdoor unit only, add .036 lbs/ft. of total liquid line length • Remote: wired or wireless must be ordered separately Outdoor Unit Indoor Unit SEER EER HSPF Nominal Cooling Capacity RZR18PVJU RZR24PVJU FAQ18PVJU FAQ24PVJU 18.6 17.6 12.7 10.2 — — 18,000 Btu/h 24,000 Btu/h RZQ18PVJU/9 RZQ24PVJU/9 FAQ18PVJU FAQ24PVJU 18.6 17.6 12.7 10.2 8.7 9.1 18,000 Btu/h 24,000 Btu/h Nominal Heating Capacity Cool Only — — H/P 20,000 Btu/h 27,000 Btu/h Line Set Optional Low Ambient Wind Baffle Optional Condensate Pump Wired Controller Wireless Controller 3/8" X 5/8" 3/8" X 5/8" KPW5E80 KPW5E80 DACA-CP1-1 DACA-CP1-1 BRC2E71 BRC2E71 BRC7E818 BRC7E818 3/8" X 5/8" 3/8" X 5/8" KPW5E80 KPW5E80 DACA-CP1-1 DACA-CP1-1 BRC2E71 BRC2E71 BRC7E818 BRC7E818 14 SkyAir Single Zone Wall Mount RKS/RXS30/36 • Warranty: 7 year compressor, 5 year parts • Maximum pipe length 98.4 ft. • Use 14/4 cable between indoor and outdoor units • Cooling down to -40 °F/-40 °C with optional field installed kit • Factory charged for up to 32 ft. of line set, add .036 lbs/ft. for line sets over 32 ft. • Wireless remote is included with wall unit, wired remote is optional Outdoor Unit Indoor Unit SEER EER HSPF RKS30LVJU RKS36LVJU FTXS30LVJU FTXS36LVJU 19.3 17.9 10.71 8,37 — — RXS30LVJU RXS36LVJU FTXS30LVJU FTXS36LVJU 19.3 17.9 10.71 8.37 8.3 8.3 Nominal Nominal Cooling Heating Capacity Capacity Cool Only 30,000 Btu/h — 36,000 Btu/h — H/P 30,000 Btu/h 34,800 Btu/h 36,000 Btu/h 38,000 Btu/h Line Set Optional Optional Low Ambient Condensate Wind Baffle Pump 3/8" X 5/8" 3/8" X 5/8" KPW5E112 KPW5E112 DACA-CP2-1 DACA-CP2-1 BRC944B2* BRC944B2* 3/8" X 5/8" 3/8" X 5/8" KPW5E112 KPW5E112 DACA-CP2-1 DACA-CP2-1 BRC944B2* BRC944B2* *BRC944B2 wired remote requires 10' or 26' wired remote control cable. BRC944B2 DACA-WB-1 2F018535-1 2F018535-2 GT1426SSF FTXS/RKS/RXS Options Wired remote controller (controller only) Wall bracket for outdoor unit Daikin RKS30 ONLY -40 ULA KIT RKS36 ONLY -40 ULA KIT Snow Stand Now with available -40 °F/-40 °C capability! 15 Optional Wired ** Controller SkyAir Single Zone 4 Way Ceiling Cassette • Warranty: 7 year compressor, 5 year parts • Factory charged for outdoor unit only, add .036 lbs/ft. of total liquid line length • 164 ft. maximum line set length • Use only 18/2 standard non-shielded cable from indoor to outdoor unit. • Cooling down to 0 °F/-18 °C with optional wind baffle • Wired or wireless remote must be ordered separately • Built in condensate pump provides up to 21" of lift • Fits standard 4 x 2 and 2 x 2 ceiling grids Nominal Cooling Capacity Outdoor Unit Indoor Unit SEER EER HSPF RZR36PVJU RZR42PVJU FCQ36MVJU FCQ42MVJU 13+ 13+ 9.6 8.1 — — 36,000 Btu/h 40,500 Btu/h RZQ36PVJU/9 RZQ42PVJU/9 FCQ36MVJU FCQ42MVJU 13+ 13+ 9.6 8.1 7.7 7.7 36,000 Btu/h 40,500 Btu/h Nominal Decoration Heating Trim Panel Capacity Cool Only — BYC125-W1 — BYC125-W1 Heat Pump 39,500 Btu/h BYC125-W1 41,600 Btu/h BYC125-W1 Line Set Optional Low Ambient \Wind Baffle Wired Controller Wireless Controller 3/8" X 5/8" 3/8" X 5/8" (2) KPW5E80 (2) KPW5E80 BRC2E71 BRC2E71 BRC7C812 BRC7C812 3/8" X 5/8" 3/8" X 5/8" (2) KPW5E80 (2) KPW5E80 BRC2E71 BRC2E71 BRC7C812 BRC7C812 16 SkyAir Single Zone Round Flow 8-Way Ceiling Cassette • Warranty: 7 year compressor, 5 year parts • Factory charged for outdoor unit only, add .036 lbs/ft. of total liquid line length • 164 ft. maximum line set length • Use only 18/2 standard non-shielded cable from indoor to outdoor unit • Cooling down to 0 °F/-18 °C with optional wind baffle • Wired remote must be ordered separately • Built in condensate pump provides up to 33" of lift Indoor Unit SEER EER HSPF Nominal Cooling Capacity RZR18PVJU RZR24PVJU RZR30PVJU RZR36PVJU RZR42PVJU FCQ18PAVJU FCQ24PAVJU FCQ30PAVJU FCQ36PAVJU FCQ42PAVJU 17.2 16.8 15.8 16.0 16.0 13.9 12.0 10.2 11.2 10.2 — — — — — 18,000 24,000 30,000 36,000 42,000 RZQ18PVJU/9 RZQ24PVJU/9 RZQ30PVJU/9 RZQ36PVJU/9 RZQ42PVJU/9 FCQ18PAVJU FCQ24PAVJU FCQ30PAVJU FCQ36PAVJU FCQ42PAVJU 17.2 16.8 15.8 17.5 16.0 13.9 12.0 10.2 11.2 10.2 10.1 9.7 9.7 8.4 8.5 18,000 24,000 30,000 36,000 47,000 Outdoor Unit Nominal Decoration Heating Trim Panel Capacity Cool Only — BYCP125K–W1 — BYCP125K–W1 — BYCP125K–W1 — BYCP125K–W1 — BYCP125K–W1 Heat Pump 20,000 BYCP125K–W1 27,000 BYCP125K–W1 34,000 BYCP125K–W1 40,000 BYCP125K–W1 42,000 BYCP125K–W1 Line Set Optional Wired Low Ambient Controller Wind Baffle 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" KPW5E80 KPW5E80 KPW5E80 (2) KPW5E80 (2) KPW5E80 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" KPW5E80 KPW5E80 KPW5E80 (2) KPW5E80 (2) KPW5E80 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 Round Flow features 8-way air distribution for more even and quieter performance. 17 Wireless Controller SkyAir-Single Zone Ceiling Suspended • Warranty: 7 year compressor, 5 year parts • Maximum line set length of 164' • Wired or wireless remote must be ordered separately • Cooling down to 0 °F/-18 °C with optional wind baffle • Factory charged for outdoor unit only, add .036 lbs/ft. of total liquid line length • Use only 18/2 standard non-shielded cable from indoor to outdoor unit Outdoor Unit Indoor Unit SEER EER HSPF Nominal Cooling Capacity RZR18PVJU RZR24PVJU RZR30PVJU RZR36PVJU RZR42PVJU FHQ18PVJU FHQ24PVJU FHQ30PVJU FHQ36MVJU FHQ42MVJU 18 18.1 17.2 14 13.8 14 12.6 10.5 10.2 9.5 — — — — — 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 40,500 Btu/h RZQ18PVJU/9 RZQ24PVJU/9 RZQ30PVJU/9 RZQ36PVJU/9 RZQ42PVJU/9 FHQ18PVJU FHQ24PVJU FHQ30PVJU FHQ36MVJU FHQ42MVJU 18 18.1 17.2 14 13.8 14 12.6 10.5 10.2 9.5 11.1 10 8.4 8.1 8.2 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 40,500 Btu/h Nominal Heating Capacity Cool Only — — — — — Heat Pump 20,000 Btu/h 27,000 Btu/h 34,000 Btu/h 37,500 Btu/h 39,500 Btu/h Line Set Low Ambient Condensate Wired Wind Baffle Pump Controller Wireless Controller 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" KPW5E80 KPW5E80 KPW5E80 (2) KPW5E80 (2) KPW5E80 DACA-CP1-1 DACA-CP1-1 DACA-CP2-1 DACA-CP2-1 DACA-CP2-1 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC7E83 BRC7E83 BRC7E83 BRC7E83 BRC7E83 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" KPW5E80 KPW5E80 KPW5E80 (2) KPW5E80 (2) KPW5E80 DACA-CP1-1 DACA-CP1-1 DACA-CP2-1 DACA-CP2-1 DACA-CP2-1 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC7E83 BRC7E83 BRC7E83 BRC7E83 BRC7E83 Great for bars, classrooms and other large open rooms. 18 SkyAir Inverter Ducted System H/P Systems • Warranty: 7 year compressor, 5 year parts • Factory charged for outdoor unit only, add .036 lbs/ft. of total liquid line length • Max length 100' for FTQ18/24 and 233' for FTQ30/36/42 • 100% heating capacity available as low as 14F, check specifications • Optional heaters available 3 and 5KW for booster or 5 thru 15KW as electric only back up • Cooling down to 0 °F/-18 °C with optional wind baffle • Wired or wireless remote must be ordered separately • Use only 18/2 standard non-shielded cable from indoor to outdoor unit • ECM blower motor Nominal Cooling Capacity 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 40,000 Btu/h Outdoor Unit Indoor Unit SEER EER HSPF RZQ18PVJU9 RZQ24PVJU9 RZQ30PVJU9 RZQ36PVJU9 RZQ42PVJU9 FTQ18PBVJU* FTQ24PBVJU* FTQ30PBVJU* FTQ36PBVJU* FTQ42PBVJU* 20.0 19.0 19.5 18.0 17.0 14.5 13.5 13.5 12.5 12 12 11.5 10 9.5 9 Model Name Electric Heater Capacity 3kW 5kW 6KW 8kW 10kW 15KW X X X NA NA NA X X X X X NA X X X X X NA X X X X X NA X X X X X X RZQ18PVJU9 RZQ24PVJU9 RZQ30PVJU9 RZQ36PVJU9 RZQ42PVJU9 19 Nominal Heating Capacity 20,000 Btu/h 27,000 Btu/h 34,000 Btu/h 40,000 Btu/h 47,000 Btu/h Electric Heater Kits HKR-03 3 KW HKR-05C 5 KW HKR-06 6 KW HKR-08C 8 KW HKR-10C 10 KW HKR-15C 15 KW External Static Pressure up to .5 W.G. up to .5 W.G. up to .5 W.G. up to .5 W.G. up to .5 W.G. Line Set 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" 3/8" X 5/8" Low Ambient Wind Baffle KPW5E80 KPW5E80 KPW5E80 (2) KPW5E80 (2) KPW5E80 Wired Controller Wireless Controller BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 FTQ ( Vertical Air Handler) Indoor Unit Accessories Wiring adaptor interface required for electric heat * KRP1C75 to operate with H/P Wiring adaptor interface required for electric heat * BRP2A81 as back up only Electric heater connection kit required for Electric * KER26A60 Heaters KRP1B101 Installation box for adaptor PCB KRP1C75 / BRP2A81 KRCS01-4 Remote sensor kit DACA-KRCS-PW40 Remote sensor cable 40 ft. DACA-KRCS-PW80 Remote sensor cable 80 ft. KKPJ5F180 Central drain plug SkyAir * Appropriate wiring adaptor will also be required when electric heaters are used. Refer to engineering guide for full details SkyAir DC Ducted H/P & Cooling Only • Warranty: 7 year compressor, 5 year parts • Maximum pipe length for 18/24/30 164' Maximum pipe length for 36/42 230' • Wired or wireless remote must be ordered separately • Use only 18/2 standard non-shielded cable from indoor to outdoor unit. • Cooling down to 0 °F/-18 °C with optional wind baffle • Factory charged for outdoor unit only, add .036 lbs/ft. of total liquid line length • Built in condensate pump with maximum 18" lift from drain opening. • Direct Drive three speed ECM motor Nominal Cooling Capacity Outdoor Unit Indoor Unit RZR18PVJU RZR24PVJU RZR30PVJU RZR36PVJU RZR42PVJU FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU 17.5 16.5 16.0 17.5 16.0 14.1 12.0 10.5 11.2 10.2 — — — — — 18000 Btu/h 24000 Btu/h 30000 Btu/h 36000 Btu/h 42000 Btu/h RZQ18PVJU/9 RZQ24PVJU/9 RZQ30PVJU/9 RZQ36PVJU/9 RZQ42PVJU/9 FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU 17.5 16.5 16.0 17.5 16.0 14.1 12.0 10.5 11.2 10.2 10.6 10.5 9.2 9.1 8.8 18000 Btu/h 24000 Btu/h 30000 Btu/h 36000 Btu/h 42000 Btu/h SEER EER HSPF Nominal Maximum Heating External Static Capacity Pressure Cool Only — .8” W.G. — .8” W.G. — .8” W.G. — .8” W.G. — .8” W.G. H/P 20000 Btu/h .8” W.G. 27000 Btu/h .8” W.G. 34000 Btu/h .8” W.G. 40000 Btu/h .8” W.G. 47000 Btu/h .8” W.G. Line Set Low Ambient Wind Baffle Wired Controller Wireless Controller 3/8” X 5/8” 3/8” X 5/8” 3/8” X 5/8” 3/8” X 5/8” 3/8” X 5/8” KPW5E80 KPW5E80 KPW5E80 (2) KPW5E80 (2) KPW5E80 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 3/8” X 5/8” 3/8” X 5/8” 3/8” X 5/8” 3/8” X 5/8” 3/8” X 5/8” KPW5E80 KPW5E80 KPW5E80 (2) KPW5E80 (2) KPW5E80 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC2E71 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 20 Indoor Unit Accessories FCQ Round Flow Ceiling Cassette Decoration panel Sealing member of air discharge outlet Panel spacer Replacement long life filter Fresh air intake kit chamber type without T shape pipe Fresh air intake kit chamber type with T shape pipe Part Number BYCP125K-W1 KDBH55K160F KDBP55H160FA KAFP551K160 KDDP55B160 KDDP55B160K FHQ Ceiling Suspended Replacement long life filter Resin net Part Number KAF501DA160 FAQ 18/24 Wall Unit Remote sensor kit Part Number KRP4A71 RZR/RZQ Outdoor unit Optional Accessories Central drain plug Fixture for preventing overturning Wire fixture for preventing overturning Wall Mount bracket Part Number KKPJ5F180 KPT-60B160 K-KYZP15C DACA-WB-3 RKS/RXS Outdoor unit Optional Accessories Drain plug Wall Mount bracket **Refer to Daikin engineering guides for more control and filter options. Part Number KKP945A4 DACA-WB-1 Tools * Part Number Service port adaptor 5/16 VALVE TO 1/4 HOSE 19173 Torque wrench 1/4” DACA-TQW1/4-1 Torque wrench 3/8” DACA-TQW3/8-1 Torque wrench 1/2” DACA-TQW1/2-1 Torque wrench 5/8” DACA-TQW5/8-1 Torque wrench 3/4” DACA-TQW3/4-1 R410A flaring tool 60295 Flare size gauge DACA-FSG-1 Deburring tool heavy duty 60163 Service tool kit; (includes gauge manifold with 5/16 hoses, flaring gauge, DACA-99STK-1 tube cutter, deburring tool and R410A flaring tool) *Daikin recommends the use of flare gauge, R410 flaring tool, deburring tool and pre-set torque wrenches on every installation. 21 What is VRV? VRV is an applied heating and cooling system that distributes refrigerant, rather than water, to multiple fan coil units serving the conditioned spaces. The features of VRV • Energy efficient • Many zones (individual control) • Centralized system (long piping) • Tight temperature control (Proportional Integral Derivative) • Large capacity (modular systems combinations) • Quiet operation • High level control (BACnet®, LionWorks®, Intelligent Manager, Intelligent Touch Controller) • Superior heating performance • Absolute comfort DC Ducted Concealed Ceiling Unit (medium static) Vertical Air Handler Unit Floor Standing Units Concealed Ceiling Unit (medium static) Slim Duct Built-in Concealed Ceiling Unit Wall Mounted Unit Round Flow Cieling Mounted Cassette 2’ x 2’ 4-Way Ceiling Mounted Cassette 100% Outside Air Processing Unit Ceiling Suspended Unit 22 VRV •Air cooled condensing unit •208-230V one phase power supply •Available in 3 and 4 Ton •Individual zone control •Can operate up to 6 or 8 fan coil units •Advanced zoning capabilities •Innovative space-saving design •Reliability •Outstanding warranties •AHRI Certified •Air cooled condensing units •Can operate up to 62 indoor fan coil units on a single system •Excellent part load performance •Auto charging function •Refrigerant charge check function •Continuous heating during defrost operation •Longest pipe lengths in product class (up to 3,280 ft.) • 208-230V or 460V three phase power supply • Advanced zoning capabilities •Water cooled condensing units (plate heat exchanger) •Available up to 21 Ton in 6 combinations •208-230V three phase power supply •Up to 32 indoor units can be connected with a choice of 11 different styles and 51 models ranging from 0.6 to 8 Ton •Connect to a cooling tower (closed loop) and boiler system •Unified heat recovery or heat pump condensing units •Cold climate capability delivering comfortable heating performance with no defrost •Long refrigerant piping length •Can be utilized in geothermal applications Daikin VRV Controls BRC2E71 BRC2A71 DCS302C71 DCS301C71 Navigation Simplified Centralized Unified Contact Your BY Territory Manager for design and application assistance with VRV 23 DCS601C71 Intelligent Touch Intelligent Manager BACnet Interface LionWorks Interface 24 25 26 27 28 29 30 31 32 33 NOTES 34 8 Locations to Serve You! Brantford # 311 Hamilton # 320 Chatham # 312 mckeough supply 360 Elgin Street Brantford, ON N3S 7P6 mckeough supply 240 Nebo Rd., Unit # 3 Hamilton, ON L8W 2E4 mckeough supply PO Box 940 30 Dover Street Chatham, ON N7M 5L3 Telephone: 905-574-4111 855-714-4822 Telephone: 519-352-7110 800-265-5251 Fax: 905-574-6555 Fax: 519-354-0749 Sarnia # 317 EMCO Sudbury #373 mckeough supply 281 Campbell Street Sarnia, ON N7T 2H2 878 Newgate Avenue Sudbury On. P3A 5J9 Telephone: 519-753-3186 800-263-8200 Fax: 519-753-8374 London # 316 mckeough supply 91 Enterprise Drive N. London, ON N6N 1A5 Telephone: 519-686-6832 800-265-4683 Telephone: 519-344-6116 Fax: 519-686-6836 Fax: 519-344-6120 Waterloo # 318 Collingwood # 313 mckeough supply 35 Baffin Place Unit B Waterloo, ON N2V 1Z2 mckeough supply 25 Sanford Fleming Drive Unit # 2 Collingwood, ON L9Y 5A6 Telephone: 519-885-1260 800-265-8240 Telephone: 705-445-5110 800-689-4421 Fax: 519-885-2365 Fax: 705-445-3461 Telephone: 705-566-0505 Fax:705-560-8002 www.mckeoughsupply.com
Similar documents
Brochure - Ductless Air Conditioner
startup when other appliances need more power. • Titanium apatite photocatalytic air purification filter decomposes odors and attracts microscopic particles that can carry bacteria and viruses. •...
More information