The calibration of Hygrometer (Lecture and Training Lecture and
Transcription
The calibration of Hygrometer (Lecture and Training Lecture and
The calibration of Hygrometer (Lecture and Training ) Japan Meteorological Agency KAWAMURA HIROSHI 川村 裕志 1 Measurement methods of Humidity(theory) Traceability and calibration methods in JMA ti ) Calibration of Hygrometer (practice About today’s practice Place: the inspection room at 1st floor 2/35 1.1 Sorption methods(2types) 1.2 Psychrometric method 1 3 Condensation C d ti methods th d (2types) (2t ) 1.3 3/35 1.1 Sorption methods(1) changes of the dimensions hair hygrometer, hair hygrograph 1.1 Sorption methods(2) changes of electrical properties electronic hygrometer (capacitive type) 1.2 Psychrometric method difference between the dry-bulb and wet-bulb t temperatureis t i related l t d to t the th ambient bi t humidity h idit aspirated psychrometer 4/35 1.3 Condensation method(1) equilibrium vapour pressure at the surface of a salt solution lithium chloride heated condensation hygrometer dewpoint p yg 1.3 Condensation method(2) sense condensation d i with i h an optical i l detector d chilled-mirror dewpoint hygrometer 5/35 hair hygrograph H i bundle b dl Hair 6/35 hair hygrograph ①Indicator adjusting screw ②Weight ③Main ccam ③ ④Sub cam ⑤Rotation axis for main cam ⑥Rotation axis for sub cam ⑦Plate attaching sensor part of humidity ⑧Screw attaching sub cam ⑨Connecting spring ⑩lever ⑪Hair bundle Structure of hair hygrograph 7/35 electronic hygrometer(capacitive type) converter sensor probe b sensor filter 8/35 electronic hygrometer(capacitive type) upper electrode upper electrode (high-porosity) polymer membrane bottom electrode glass plate 9/35 electronic hygrometer(capacitive type) upper electrode upper electrode (high-porosity) l polymer membrane bottom electrode glass plate 10/35 electronic hygrometer(capacitive type) H2O upper electrode upper electrode (high-porosity) l polymer membrane bottom electrode glass plate 11/35 electronic hygrometer(capacitive type) changes h in i capacitive iti between b t electrodes l t d (low humidity) (high humidity) 12/35 aspirated psychrometer JMA type Assuman type wet-bulb dry-bulb 13/35 14/35 lithium chloride heated condensation dewpoint p hygrometer yg ((dew cell)) resistance thermometer wire as electrodes humidity-sensitive part ・An operational equilibrium temperature exists for the instrument, depending upon the ambient water-vapour pressure. At the equilibrium temperature,neither evaporation nor condensation occurs because the equilibrium vapour pressure and the ambient vapour pressure are equal. 15/35 chilled-mirror dewpoint hygrometer 感部 ・ measurement of Td or Tf . ・ small polished-metal reflecting surface cooled electrically by using a Peltier-effect device sense condensation with an optical detector.・ 16/35 17/35 Temperature, p , Humidity, Pressure, ・・・ (Without radiation) Traceability chart of JMA International Standard (SI unit) National Primary Standard (National Metrology Institute of Japan) JMA National meteorological standard (JMA standard) Working W ki standards d d (JMA sub-standard) ( ) MIC(RIC) Working instruments (Observation sites) 18/35 Traceability of Humidity (JMA) National Primary Standard National Metrology Institute of Japan Standard humidity generator set Calibration : every year JMA Standard Working Standard Meteorological Instruments Center Chilled-mirror dewpoint p hygrometer Hygrometer (display) DewStar S-1M-0 (Shinyei technology, Japan) Hygrometer (sensor) DewStar S-2S-0K S 2S 0K (Shinyei technology, Japan) Feb. 2012 by JMA Field Instruments Observatory Chilled-mirror dewpoint p hygrometer Hygrometer (controller) Hygro M2 (General Eastern, USA) Hygrometer (sensor) D2 (General Eastern, USA) Electronic hygrometer Calibration : every year Filter change: Every 6 months Check: ・every 3 months (manned observatory) ・every year (automatic weather station) Tolerable range:±4% Aspirated psychrometer Lithium chloride dewpoint hygrometer Check: at the time of installation JMA Standard of thermometer Mercury-in-glass thermometer (Assuman type 19/35 psychrometer) Sensor unit Monitor Chilled-mirror dewpoint hygrometer 20/35 JMA Standard DT 12.3 ℃ Humidity H idit generator g r t r (Wet and dry air mixing type) DT 12.6 12 6 ℃ W ki St d d Working Standard Fl dj t :Flow adjuster 21/35 22/35 Traceability of Humidity (JMA) National Primary Standard National Metrology Institute of Japan Standard humidity generator set Calibration : every year JMA Standard Working Standard Meteorological Instruments Center Chilled-mirror dewpoint p hygrometer Hygrometer (display) DewStar S-1M-0 (Shinyei technology, Japan) Hygrometer (sensor) DewStar S-2S-0K S 2S 0K (Shinyei technology, Japan) Feb. 2012 by JMA Field Instruments Observatory Chilled-mirror dewpoint p hygrometer Hygrometer (controller) Hygro M2 (General Eastern, USA) Hygrometer (sensor) D2 (General Eastern, USA) Electronic hygrometer Calibration : every year Filter change: Every 6 months Check: ・every 3 months (manned observatory) ・every year (automatic weather station) Tolerable range:±4% Aspirated psychrometer Lithium chloride dewpoint hygrometer Check: at the time of installation JMA Standard of thermometer Mercury-in-glass thermometer (Assuman type 23/35 psychrometer) chamber(constant-temperature) p H 76.5%RH Humidity generator (Wet and dry air mixing type) Field Instruments (Electronic hygrometer) Working Standard Thermometer Working Standard DT 12.5 ℃ Pump T 23.0 ℃ 24/35 Traceability of Humidity (JMA) National Primary Standard National Metrology Institute of Japan Standard humidity generator set Calibration : every year JMA Standard Working Standard Meteorological Instruments Center Chilled-mirror dewpoint p hygrometer Hygrometer (display) DewStar S-1M-0 (Shinyei technology, Japan) Hygrometer (sensor) DewStar S-2S-0K S 2S 0K (Shinyei technology, Japan) Feb. 2012 by JMA Field Instruments Observatory Chilled-mirror dewpoint p hygrometer Hygrometer (controller) Hygro M2 (General Eastern, USA) Hygrometer (sensor) D2 (General Eastern, USA) Electronic hygrometer Calibration : every year Filter change: Every 6 months Check: ・every 3 months (manned observatory) ・every year (automatic weather station) Tolerable range:±4% Aspirated psychrometer Lithium chloride dewpoint hygrometer Check: at the time of installation JMA Standard of thermometer Mercury-in-glass thermometer (Assuman type psychrometer) 26/35 Thermometer Hygrometer Air flow 27/35 28/35 Comparisons against a reference instrument Standard Calibration Relative humidity ex) 20[%],40[%] ,60[%] ,80[%] ,95[%] at 23[℃]±3[℃] Dew point temperature ex) -5[℃] ,0[℃] ,5[℃] ,10[℃] ,15[℃] ,20[℃] ,25[℃] under suitable steady conditions Humidity chamber Dynamic two-pressure humidity generator Wet and dry air mixed-flow generator (MIC using) etc. Saturated salt solutions 29/35 constant-temperature bath controlled by liquid circulator Saturation tank Dry air Chamber Flow controller [diagram of system] 30/35 Vessels containing saturated solutions of appropriate salts mayy be used to calibrate relative humidityy sensors. Barium chloride (BaCl2): 90.3 % Sodium chloride (NaCl) (NaCl): 75.3 % Magnesium nitrate (Mg(NO3)2): 52.9 % Calcium chloride (CaCl2): 29.0 % Lithium chloride (LiCl) (LiCl): 11.1 % etc. at 25°C 31/35 ex) Vaisala HMK15 Refer to User Guide 32/35 Comparisons against a reference instrument under d the th room Purpose: Check the difference between the Hygrometers. Reference Hygrometer: “Chilled-mirror dewpoint hygrometer“ “Platinum resistance thermometer“ Hygrometer1:“Electronic hygrometer“ Hygrometer2: “Hair hygrograph“ Hygrometer3:“Aspirated psychrometer“ Demonstrations:Chilled-mirror dewpoint hygrometer setting Saturated salt solutions(NaCl) setting Group A; Bangladesh Cambodia Lao PDR Maldives Mongolia Myanmar Nepal For Group A For Group B Hygrometer 1,2,3 And Reference Hygrometer 1,2,3 And Reference ※ 1st floor Calibbration chaamber Calibration chambers Group B; Oman Pakistan Qatar Sri Lanka Th il d Thailand Viet Nam 34/35 Example (Group A) Dewpoint temperature 1st The time of reading No. 1 2 3 4 5 6 7 Reference(HYGRO M-2) (Example) Bangladesh Cambodia Laos Maldives Mongolia Myanmar Nepal hh:mm 15:00 : : : : : : : The value of correction reading [℃] -5.9 ① [℃] The value of correction reading 1 2 3 4 5 6 7 (Example) Bangladesh Cambodia Laos Maldives Mongolia Myanmar Nepal - [℃] 10.9 vapour pressure in air ※1 corrected value [℃] Reference (F-250) [℃] Saturation vapour pressure※1 The value of corrected correction reading value [hPa] [℃] 22.225 [℃] ② Wet Bulb No. Air temperature [℃] [hPa] Relative humidity[B] Reference value [%RH] ③ p ppsychrometer y Aspirated Dry Bulb ⑥ corrected value(T) The value of reading [℃] [℃] 22.5 ⑦ Calibrated Hygrometer's reading value Electronic hygrometer [%RH] 14.31 Hair hygrometer [%RH] 21 ④⑤ correction corrected value(Tw) T-Tw [℃] [℃] [℃] Atmospheric pressure [hPa] 1009.80 Relative ⑧humidity※2 [%RH] - Please pass the staff after finished. Please read twice (①→⑧ ①→⑧) 36/35