CardioScan Stress Test

Transcription

CardioScan Stress Test
DM Software
Wireless or USB Acquisition
Bluetooth Module:
Transmitter & Receiver
High Sample Rate 4000 S/sec
100 Mtrs open air range
Standard ECG Patient
Cable - Short
Mini USB
Acquisition Device
DMS 300-4
High Sample Rate
4000 S/sec
Mini Holter ECG
Patient Cable
Quality Stress Test Features
PC Based Stress Test ECG
Windows XP, Vista
New Filtering Technique for
Remarkable ECG Quality
New Customizable Screen Displays
Treadmill and Ergometer Profiles
under one Software Platform
Ultra Simple Protocol Creation &
Unlimited number of protocols
Summary ~ ST Scan ~ Trends ~ HR
Recovery Graph min/min ~ Full
Disclosure ~ ECG Strips ~ T-Wave
Alternans ~ 3D ST ~ Maximum
NIBP, VO2, Stress Echo, HL7,
GDT, SQL, ASCII, PDF interfaces
Quality Stress Test Features
F1 – Pretest… start Resting ECG
F2 – Exercise... pass to Exercise and next exercise
stage
F3 – Recovery…pass to recovery
F4 – End…End the test but continue to display
ECG until leads are taken off
F5 – Hold…hold the stage as long desired
F6 – Comment… type your own comments for
this stage during the test
F7 – BP… take manual NIBP measurements at
any time during the test
F8 – Mark… place a vertical marker on the full
disclosure ECG to locate any event and save ECG
strips
F9 – Print… print real time ECG strips during
the test
Conclusion… start building your conclusions at
any time during exercise, recovery or after the test
ended
Info… change patient info
Auto… go from Auto to Manual control of
Treadmill/Ergometer and back
Mode…change continuous ECG display from 12Lead to 6-Lead V1-V6 Leads or I-Avf
Settings… enable or disable filters, increase or
decrease speed and gain
Customized Displays
Ref ECG , 12-Lead ECG
|
“Summary”
Ref ECG, I-aVF Leads
|
Table
Ref ECG, V1-V6 Leads
| V5 Ref /Actual Beat
Ref ECG , 12-Lead ECG |
Page Scan
User Friendly Operation Protocol
Main Menu with Patient Data
Base
Ultra Simple Protocol Creation
Easy Stress Test Operations
Conclusions & Report
Stress Test Review
Main Menu with Database
Direct access to patient Data Base from main menu with all functions
Select patient and review report as well as ECG sample on main menu
Create Patient Categories and/or Doctor Directories
TreadMill & Ergometer Interface Protocols
Select Treadmill or Ergometer
Interface in a second
Change Settings for each type of
test
Create as many user profles and
settings as desired
Extremely simple Protocol
Creation for Ergometer and
Treadmill
Define time for Auto ECG
Printouts for each stage as
desired
Define NIBP protocol
measurement manual/auto and
measurement time for each stage
Super Easy Stress Test Operations
F1 – New Patient …
enter patient info or auto fill in
patient info from data base or
external data base via optional
HL7/GDT/VO2…interfaces
select other protocol than default,
change BP input mode,
Or Change Max HR calculation
… if desired by user
Use either Keyboard or Mouse or
Finger on Tactile Screen to select
F1 - Pretest / F2 – Exercise /
F3 – Recovery
And all other function buttons
Define ECG screen display colors
for continuous and
superimposed ECG, and for
Pretest/Exercise/Recovery
Abnormal Values will
immediately be displayed in Red
Conclusions and Report
Conclusions…
Start typing your conclusions
during recovery or after end
of the test with continuous
display of EGC until patient
is unhooked
Select from Dictionary preentered comments, labels or
phrases to avoid typing
Summary…
To review and modify
conclusions, review
numerical data results of test
Preview and Print Summary
Report
Report….
To preview and select reports
to be printed
Multiple Reports Selection
Multiple Stress Test Review Displays
ST Scan Menu for ST review and re-analysis
T- Wave Alternans Detection and Review of
any part of the entire ECG data
Full Disclosure + ECG Strips Display & Print outs
Heart Rate Graph with
Minute by Minute HR
Recovery and Full
Disclosure Display
access
Blue-tooth ECG transmitter and receiver
(Model:DMS300-BTT-01/BTR-01)
Blue-tooth ECG transmitter and receiver
Method of transmitting and receiving: Digital;
Transmitting and receiving frequency: 2.4G Hz;
Working distance: Model: 15m visible;
Transmitter voltage: DC 6.0V;
Receiver voltage: DC 5.0V.
Sample rate: <=4096Hz;
Sample resolution: 12bit;
Lead: 12-lead standard ECG;
Input circuit current: ≤0.1µA;
Input impedance: ≥5 MΩ;
Noise electric level: ≤15μVp-p;
Standard sensitivity: 10mm/mV ±5%;
Anti-polarization voltage: if add ±300mV DC polarization
voltage, the change of sensitivity is not more than ±5%;
CMRR: ≥60 dB;
Frequency response: 0.5 -150 Hz(+0.4 dB, -3.0 dB);
Lower frequency feature: time constant is not less than
3.2s;
Stability: when the power supply transient change is 10%,
the baseline wondering is not more than ±5%. The
sensitivity error is not more than ±5%.50Hz filter: ≥20dB;
Equipment safety type: the wired ECG acquisition box is
class II, type-BF; the blue-tooth ECG transmitter is type-BF
with internal power; the blue-tooth ECG receiver is class II,
type-B;
Working environment: Temperature: 10 - 30℃, Relative
humidity: ≤70%, Atmospheric pressure: 860 - 1060hPa;
Storage environment: Temperature: -20 - 55℃, Relative
humidity: ≤93%, Atmospheric pressure: 500 - 1060hPa.
DMS300-BTT-01
DMS300-BTT-01
Bluetooth Transmitter (front)
Bluetooth Transmitter (back)
DMS300-BTR-01
Bluetooth Receiver
Patient Cables
1. Connect the Bluetooth receiver to the USB port
of the computer.
2. Connect the patient cable to the DMS300-BTT01 Bluetooth transmitter.
3. Insert the batteries into the Bluetooth
transmitter.
4. Hold the power switch at the top of the
Bluetooth transmitter for 3 seconds. The LED
lights on the front will light up to indicate it is
on and active.
5. For Software Installation Demonstration please
double click on the link below:
Install StressTest.exe