CardioScan Stress Test
Transcription
CardioScan Stress Test
DM Software Wireless or USB Acquisition Bluetooth Module: Transmitter & Receiver High Sample Rate 4000 S/sec 100 Mtrs open air range Standard ECG Patient Cable - Short Mini USB Acquisition Device DMS 300-4 High Sample Rate 4000 S/sec Mini Holter ECG Patient Cable Quality Stress Test Features PC Based Stress Test ECG Windows XP, Vista New Filtering Technique for Remarkable ECG Quality New Customizable Screen Displays Treadmill and Ergometer Profiles under one Software Platform Ultra Simple Protocol Creation & Unlimited number of protocols Summary ~ ST Scan ~ Trends ~ HR Recovery Graph min/min ~ Full Disclosure ~ ECG Strips ~ T-Wave Alternans ~ 3D ST ~ Maximum NIBP, VO2, Stress Echo, HL7, GDT, SQL, ASCII, PDF interfaces Quality Stress Test Features F1 – Pretest… start Resting ECG F2 – Exercise... pass to Exercise and next exercise stage F3 – Recovery…pass to recovery F4 – End…End the test but continue to display ECG until leads are taken off F5 – Hold…hold the stage as long desired F6 – Comment… type your own comments for this stage during the test F7 – BP… take manual NIBP measurements at any time during the test F8 – Mark… place a vertical marker on the full disclosure ECG to locate any event and save ECG strips F9 – Print… print real time ECG strips during the test Conclusion… start building your conclusions at any time during exercise, recovery or after the test ended Info… change patient info Auto… go from Auto to Manual control of Treadmill/Ergometer and back Mode…change continuous ECG display from 12Lead to 6-Lead V1-V6 Leads or I-Avf Settings… enable or disable filters, increase or decrease speed and gain Customized Displays Ref ECG , 12-Lead ECG | “Summary” Ref ECG, I-aVF Leads | Table Ref ECG, V1-V6 Leads | V5 Ref /Actual Beat Ref ECG , 12-Lead ECG | Page Scan User Friendly Operation Protocol Main Menu with Patient Data Base Ultra Simple Protocol Creation Easy Stress Test Operations Conclusions & Report Stress Test Review Main Menu with Database Direct access to patient Data Base from main menu with all functions Select patient and review report as well as ECG sample on main menu Create Patient Categories and/or Doctor Directories TreadMill & Ergometer Interface Protocols Select Treadmill or Ergometer Interface in a second Change Settings for each type of test Create as many user profles and settings as desired Extremely simple Protocol Creation for Ergometer and Treadmill Define time for Auto ECG Printouts for each stage as desired Define NIBP protocol measurement manual/auto and measurement time for each stage Super Easy Stress Test Operations F1 – New Patient … enter patient info or auto fill in patient info from data base or external data base via optional HL7/GDT/VO2…interfaces select other protocol than default, change BP input mode, Or Change Max HR calculation … if desired by user Use either Keyboard or Mouse or Finger on Tactile Screen to select F1 - Pretest / F2 – Exercise / F3 – Recovery And all other function buttons Define ECG screen display colors for continuous and superimposed ECG, and for Pretest/Exercise/Recovery Abnormal Values will immediately be displayed in Red Conclusions and Report Conclusions… Start typing your conclusions during recovery or after end of the test with continuous display of EGC until patient is unhooked Select from Dictionary preentered comments, labels or phrases to avoid typing Summary… To review and modify conclusions, review numerical data results of test Preview and Print Summary Report Report…. To preview and select reports to be printed Multiple Reports Selection Multiple Stress Test Review Displays ST Scan Menu for ST review and re-analysis T- Wave Alternans Detection and Review of any part of the entire ECG data Full Disclosure + ECG Strips Display & Print outs Heart Rate Graph with Minute by Minute HR Recovery and Full Disclosure Display access Blue-tooth ECG transmitter and receiver (Model:DMS300-BTT-01/BTR-01) Blue-tooth ECG transmitter and receiver Method of transmitting and receiving: Digital; Transmitting and receiving frequency: 2.4G Hz; Working distance: Model: 15m visible; Transmitter voltage: DC 6.0V; Receiver voltage: DC 5.0V. Sample rate: <=4096Hz; Sample resolution: 12bit; Lead: 12-lead standard ECG; Input circuit current: ≤0.1µA; Input impedance: ≥5 MΩ; Noise electric level: ≤15μVp-p; Standard sensitivity: 10mm/mV ±5%; Anti-polarization voltage: if add ±300mV DC polarization voltage, the change of sensitivity is not more than ±5%; CMRR: ≥60 dB; Frequency response: 0.5 -150 Hz(+0.4 dB, -3.0 dB); Lower frequency feature: time constant is not less than 3.2s; Stability: when the power supply transient change is 10%, the baseline wondering is not more than ±5%. The sensitivity error is not more than ±5%.50Hz filter: ≥20dB; Equipment safety type: the wired ECG acquisition box is class II, type-BF; the blue-tooth ECG transmitter is type-BF with internal power; the blue-tooth ECG receiver is class II, type-B; Working environment: Temperature: 10 - 30℃, Relative humidity: ≤70%, Atmospheric pressure: 860 - 1060hPa; Storage environment: Temperature: -20 - 55℃, Relative humidity: ≤93%, Atmospheric pressure: 500 - 1060hPa. DMS300-BTT-01 DMS300-BTT-01 Bluetooth Transmitter (front) Bluetooth Transmitter (back) DMS300-BTR-01 Bluetooth Receiver Patient Cables 1. Connect the Bluetooth receiver to the USB port of the computer. 2. Connect the patient cable to the DMS300-BTT01 Bluetooth transmitter. 3. Insert the batteries into the Bluetooth transmitter. 4. Hold the power switch at the top of the Bluetooth transmitter for 3 seconds. The LED lights on the front will light up to indicate it is on and active. 5. For Software Installation Demonstration please double click on the link below: Install StressTest.exe