Schneider Altivar ATV12 Quick Start Guide

Transcription

Schneider Altivar ATV12 Quick Start Guide
Quick Start Guide - ATV12
ENGLISH
S1A5614601
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Read and understand this quick start guide before performing any procedure with this drive.
• The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all
equipment.
• Many parts of this drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools.
• DO NOT touch unshielded components or terminal strip screw connections with voltage present.
• DO NOT short across terminals PA/+ and PC/- or across the DC bus capacitors.
• Before servicing the drive:
- Disconnect all power, including external control power that may be present.
- Place a "DO NOT TURN ON" label on all power disconnects.
- Lock all power disconnects in the open position.
- WAIT 15 MINUTES to allow the DC bus capacitors to discharge.
- Measure the voltage of the DC bus between the PA/+ and PC/- terminals to ensure that the voltage is less than 42 Vdc.
- If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate
the drive
• Install and close all covers before applying power or starting and stopping the drive.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider
Electric for any consequences arising out of the use of this product.
Information below is designed to use single drive connected to single motor with a motor cable length less than 50 meters (164 ft).
In any other case, consult the ATV12 user manual on www.schneider-electric.com.
Check your cables before connecting the drive with motor (length, power, shielded or unshielded). Motor cable length is _______(< 50 meters, 164 ft)
1
Check the delivery of the drive
• Remove ATV12 from the packaging and check that it has not been damaged.
WARNING
DAMAGED DRIVE EQUIPMENT
Do not operate or install any drive or drive accessory that appears damaged.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
• Check that the drive reference printed on the label is the same as that on the delivery note corresponding to the
purchase order.
ATV12HU15M2
1.5KW - 2HP - 200 / 240V
Write the drive Model Reference: _____________ ___________and Serial Number: ____________________________
2
Check the line voltage compatibility
• Check that the line voltage is compatible with the supply range of the drive.
Line voltage _______ Volts
Drive voltage range _______ Volts
Drive range: ATV12
F1 = 100 ... 120 V single phase / ATV12
M2=200 ... 240 V single phase / ATV12
3
8B0915316127
M3 = 200 ... 240 V three-phase.
Mount the drive vertically
(a)
For a surrounding air temperature up to 50 °C (122 °F)
(a)
(a)
(a)
(b)
(a) 50 mm (2 in.)
(b)
10 mm (0.4 in.)
See user manual on www.schneider-electric.com for other thermal conditions.
www.schneider-electric.com
1/4
S1A56146 - 05/2010
4
Connect the drive:
Control choice
Connect the drive: Power
5
• Wire the drive to the ground.
• Check circuit breaker rating or fuse rating.
• Check that the motor voltage is compatible with the drive voltage.
Motor voltage ______Volts.
• Wire the drive to the motor.
• Wire the drive to the line supply.
[REMOTE configuration]
5.1 (Control by external reference)
or
ATV12F1
COM
AI 1
+5v
• Wire the speed reference:
Do:
6 + 7 + 8 + 9.1
Do:
6 + 7 + 8 + 9.1
Do:
6 + 7 + 8 + 9.1
Do:
6 + 7 + 8 + 9.2
2.2 KΩ
• Wire the command:
Control command 2-wire:
Parameter tCC = 2C
ATV12M2
LI1: forward
LIx: reverse
ATV 12
LI1
+24 V
LIx
ATV12M3
Control command 3-wire:
Parameter tCC = 3C
LI1: stop
LI2: forward
LIx: reverse
0,8...1,2 N.m
7.1...10.6 lb.in
ATV 12
+24 V
LI1
LI2
LIx
200...240V
[LOCAL configuration]
5.2 (control by internal reference).
.
6
•
•
•
•
Apply power to the drive
Check that used Logic Inputs are not active (see Li1, Li2, Lix ).
Apply power to the drive.
Drive displays bFr at first power up.
On next start-ups, drive displays rdY .
7
Set motor parameters
• See on the motor Nameplate to set the following parameters.
Menu
COnF > FULL >
drC[Motor control menu]
Code
bFr
nPr
nCr
8
Description
Factory setting
[Standard motor frequency]:
Standard motor frequency (Hz)
[Rated motor power]:
Nominal motor power on motor nameplate
[Rated motor current]:
Nominal motor current on motor nameplate (A)
50.0
Customer
setting
drive rating
drive rating
Set basic parameters
Menu
Code
ACC
COnF
[CONFIGURATION]
dEC
LSP
HSP
www.schneider-electric.com
Description
Factory setting
[Acceleration]:
Acceleration time (s)
[Deceleration]:
Deceleration time (s)
[Low speed]:
Motor frequency at minimum reference (Hz)
[High speed]:
Motor frequency at maximum reference (Hz)
3.0
2/4
Customer
setting
3.0
0.0
50.0
S1A56146 - 05/2010
9
Set control choice
Menu
COnF > FULL >
Ctl[Control menu]
COnF > FULL >
I_0[Input Output menu]
5.1 [REMOTE configuration]
5.2 [LOCAL configuration]
[Reference channel1]:
Reference control
Al1
AlU1
[Type of control]:
Command control
2C: 2-wire control
3C: 3-wire control
_
Code
Description
Fr1
tCC
9.1 [REMOTE configuration]
(configuration factory setting)
Parameters factory settings:
Fr1 = AI1
tCC = 2C
Customer Setting
9.2 [LOCAL configuration]
Parameters factory settings:
Fr1 = AIU1
MODE
3s
LOC
rdY
35.
1
[Analog input virtual] (Hz)
10
Start the motor
www.schneider-electric.com
3/4
S1A56146 - 05/2010
Menus structure
[REMOTE configuration]
[LOCAL configuration]
MODE
ESC
3s
LOC
2s
rdY
rEN
rdY
MODE
ESC
ENT
3s
35.
[Analog input virtual] (Hz)
ESC
ESC
rEF
MODE
ESC
MODE
MOn
[SPEED REFERENCE]
rEF
COnF
[MONITORING]
[CONFIGURATION]
MOn
COnF
(2)
ESC
(1)
ENT
(2)
ESC
MODE
0.
0
0
2s / ESC
bFr
50
Fr1
AI1
ACC
3
dEC
3
LSP
0
HSp
50
HErt
2s / ESC
ENT
51.
3
HErt
2s / ESC
(1)
LFr
AIU1
FrH
rPI
rPC
Frh
0
rFr
0.
0
2s / ESC
LCr
2s / ESC
HErt
2s / ESC
HErt
0.
0
2s / ESC
AMP
2s / ESC
nPr
rPE
2s / ESC
2s / ESC
2s / ESC
SEC
SEC
HErt
HErt
At
2s / ESC
nCr
rPF
2s / ESC
AI1t
rPC
2s / ESC
AMP
5U
SCS
2s / ESC
FCS
2s / ESC
CFG
2s / ESC
I_02s / ESC
drC2s / ESC
CtL-
rdY
FUn-
(2)
COd
(2)
LFr
AIU1
LFr
AIU1
FLtCON-
Refer to the user manual for comprehensive menu description.
A dash appears after menu codes to differentiate them from parameter codes.
Example: [Motor control menu] (drC-), bFr parameter.
www.schneider-electric.com
4/4
S1A56146 - 05/2010