Schneider Altivar ATV12 Quick Start Guide
Transcription
Schneider Altivar ATV12 Quick Start Guide
Quick Start Guide - ATV12 ENGLISH S1A5614601 DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • Read and understand this quick start guide before performing any procedure with this drive. • The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all equipment. • Many parts of this drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools. • DO NOT touch unshielded components or terminal strip screw connections with voltage present. • DO NOT short across terminals PA/+ and PC/- or across the DC bus capacitors. • Before servicing the drive: - Disconnect all power, including external control power that may be present. - Place a "DO NOT TURN ON" label on all power disconnects. - Lock all power disconnects in the open position. - WAIT 15 MINUTES to allow the DC bus capacitors to discharge. - Measure the voltage of the DC bus between the PA/+ and PC/- terminals to ensure that the voltage is less than 42 Vdc. - If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate the drive • Install and close all covers before applying power or starting and stopping the drive. Failure to follow these instructions will result in death or serious injury. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this product. Information below is designed to use single drive connected to single motor with a motor cable length less than 50 meters (164 ft). In any other case, consult the ATV12 user manual on www.schneider-electric.com. Check your cables before connecting the drive with motor (length, power, shielded or unshielded). Motor cable length is _______(< 50 meters, 164 ft) 1 Check the delivery of the drive • Remove ATV12 from the packaging and check that it has not been damaged. WARNING DAMAGED DRIVE EQUIPMENT Do not operate or install any drive or drive accessory that appears damaged. Failure to follow these instructions can result in death, serious injury, or equipment damage. • Check that the drive reference printed on the label is the same as that on the delivery note corresponding to the purchase order. ATV12HU15M2 1.5KW - 2HP - 200 / 240V Write the drive Model Reference: _____________ ___________and Serial Number: ____________________________ 2 Check the line voltage compatibility • Check that the line voltage is compatible with the supply range of the drive. Line voltage _______ Volts Drive voltage range _______ Volts Drive range: ATV12 F1 = 100 ... 120 V single phase / ATV12 M2=200 ... 240 V single phase / ATV12 3 8B0915316127 M3 = 200 ... 240 V three-phase. Mount the drive vertically (a) For a surrounding air temperature up to 50 °C (122 °F) (a) (a) (a) (b) (a) 50 mm (2 in.) (b) 10 mm (0.4 in.) See user manual on www.schneider-electric.com for other thermal conditions. www.schneider-electric.com 1/4 S1A56146 - 05/2010 4 Connect the drive: Control choice Connect the drive: Power 5 • Wire the drive to the ground. • Check circuit breaker rating or fuse rating. • Check that the motor voltage is compatible with the drive voltage. Motor voltage ______Volts. • Wire the drive to the motor. • Wire the drive to the line supply. [REMOTE configuration] 5.1 (Control by external reference) or ATV12F1 COM AI 1 +5v • Wire the speed reference: Do: 6 + 7 + 8 + 9.1 Do: 6 + 7 + 8 + 9.1 Do: 6 + 7 + 8 + 9.1 Do: 6 + 7 + 8 + 9.2 2.2 KΩ • Wire the command: Control command 2-wire: Parameter tCC = 2C ATV12M2 LI1: forward LIx: reverse ATV 12 LI1 +24 V LIx ATV12M3 Control command 3-wire: Parameter tCC = 3C LI1: stop LI2: forward LIx: reverse 0,8...1,2 N.m 7.1...10.6 lb.in ATV 12 +24 V LI1 LI2 LIx 200...240V [LOCAL configuration] 5.2 (control by internal reference). . 6 • • • • Apply power to the drive Check that used Logic Inputs are not active (see Li1, Li2, Lix ). Apply power to the drive. Drive displays bFr at first power up. On next start-ups, drive displays rdY . 7 Set motor parameters • See on the motor Nameplate to set the following parameters. Menu COnF > FULL > drC[Motor control menu] Code bFr nPr nCr 8 Description Factory setting [Standard motor frequency]: Standard motor frequency (Hz) [Rated motor power]: Nominal motor power on motor nameplate [Rated motor current]: Nominal motor current on motor nameplate (A) 50.0 Customer setting drive rating drive rating Set basic parameters Menu Code ACC COnF [CONFIGURATION] dEC LSP HSP www.schneider-electric.com Description Factory setting [Acceleration]: Acceleration time (s) [Deceleration]: Deceleration time (s) [Low speed]: Motor frequency at minimum reference (Hz) [High speed]: Motor frequency at maximum reference (Hz) 3.0 2/4 Customer setting 3.0 0.0 50.0 S1A56146 - 05/2010 9 Set control choice Menu COnF > FULL > Ctl[Control menu] COnF > FULL > I_0[Input Output menu] 5.1 [REMOTE configuration] 5.2 [LOCAL configuration] [Reference channel1]: Reference control Al1 AlU1 [Type of control]: Command control 2C: 2-wire control 3C: 3-wire control _ Code Description Fr1 tCC 9.1 [REMOTE configuration] (configuration factory setting) Parameters factory settings: Fr1 = AI1 tCC = 2C Customer Setting 9.2 [LOCAL configuration] Parameters factory settings: Fr1 = AIU1 MODE 3s LOC rdY 35. 1 [Analog input virtual] (Hz) 10 Start the motor www.schneider-electric.com 3/4 S1A56146 - 05/2010 Menus structure [REMOTE configuration] [LOCAL configuration] MODE ESC 3s LOC 2s rdY rEN rdY MODE ESC ENT 3s 35. [Analog input virtual] (Hz) ESC ESC rEF MODE ESC MODE MOn [SPEED REFERENCE] rEF COnF [MONITORING] [CONFIGURATION] MOn COnF (2) ESC (1) ENT (2) ESC MODE 0. 0 0 2s / ESC bFr 50 Fr1 AI1 ACC 3 dEC 3 LSP 0 HSp 50 HErt 2s / ESC ENT 51. 3 HErt 2s / ESC (1) LFr AIU1 FrH rPI rPC Frh 0 rFr 0. 0 2s / ESC LCr 2s / ESC HErt 2s / ESC HErt 0. 0 2s / ESC AMP 2s / ESC nPr rPE 2s / ESC 2s / ESC 2s / ESC SEC SEC HErt HErt At 2s / ESC nCr rPF 2s / ESC AI1t rPC 2s / ESC AMP 5U SCS 2s / ESC FCS 2s / ESC CFG 2s / ESC I_02s / ESC drC2s / ESC CtL- rdY FUn- (2) COd (2) LFr AIU1 LFr AIU1 FLtCON- Refer to the user manual for comprehensive menu description. A dash appears after menu codes to differentiate them from parameter codes. Example: [Motor control menu] (drC-), bFr parameter. www.schneider-electric.com 4/4 S1A56146 - 05/2010