LG 1400 PHI-certified
Transcription
LG 1400 PHI-certified
SYSTEM VENTECH LG 1400 COMFORT VENTILATION for residential buildings for non-residential buildings EN13141-7:2010 ErP 2018 EU Regulation 1253/2014 Systematic ventilation. S YS TE M VE NTE CH LG 1400 PAGE 2 Product description The LG 1400, VENTECH system, comfort ventilation unit with passive house certificate consists of a compact, thermal bridge-free and 50 mm heatinsulated housing made of galvanised steel sheeting, external powder coating in RAL 9010, a highly efficient heat recovery system with air/air counter- flow heat exchanger, an automatic 100% bypass with energy-saving radial fans in the latest EC motor technology with optional CO2 sensor module for demand-based comfort ventilation operation, air filter of quality class F7 in the outdoor air and G4 in the extract air, internally wired control electronics. Optional enhancements such as constant volume flow regulation, constant pressure regulation or our enhanced, efficiency-optimised Pichler System Optimizer regulation complement the extensive basic functions. Compact ventilation unit suitable for free-standing installation in frost-free rooms. and similar applications and for the controlled mechanical aeration and ventilation of larger apartment buildings. The range of use extends fundamentally to residential buildings in passive or lowenergy construction, with an adjustable air volume flow up to approx. 1500 m³/h. Area of application The VENTECH system LG 1400 and LG 1400 S comfort ventilation unit is used as a central unit for up to 17 apartments, schools, doctor's surgeries, offices Layout sketch LG 1400 (free-standing installation) Air line connection: outdoor air / exhaust air / supply air / extract air (W x H) 200 x 596 mm Air line connection: with connecting profile P30 21 18 8 16 21 21 21 11 245 375 125 14 17 9 6 12 1528 1000 10 5 7 1288 15 19 365 150 1390 1445 570 13 1 20 81 2 775 3 600 4 380 1 Supply air 200 x 596 mm 2 Extract air 200 x 596 mm 3 Outdoor air 200 x 596 mm 4 Exhaust air 200 x 596 mm 5 Counterflow heat exchanger 6 Exhaust air fan 7 Supply air fan 8 Control system 9 Bypass damper with actuator 10Extract air filter 11 Outdoor air filter 12 Condensate tray 13 Cable inlets 2 x M20, 8 x M16 14E lectric preheater battery (optional), with an optional heat insulation 15 Electric reheater battery (optional) 16 Outdoor air shut-off valve (optional) 17 Exhaust air shut-off valve (optional) 18 Control panel (optional) 19 Height adjustable feet 2 0 Condensate drain 21 Flexible connections top Optional: Hot water preheater battery and hot water preheater battery for duct installation Figure: LG 1400 R (right-hand version) 365 200 315 200 365 S YS TE M VE NTE CH LG 1400 PAGE 3 Layout sketch LG 1400 S (free-standing installation) Air line connection: outdoor air / extract air (W x H) 200 x 596 mm Air line connection: exhaust air / supply air (W x H) 286 x 586 mm Air line connection: with connecting profile P30 21 18 8 21 125 14 11 245 375 16 22 5 1000 1288 10 17 9 6 1528 286 15 22 586 7 12 19 365 150 1390 1445 570 13 85 2 775 600 3 1 4 365 200 315 1955 380 200 365 120 135 20 1 Supply air 286 x 586 x mm 2 Extract air 200 x 596 mm 3 Outdoor air 200 x 596 mm 4 Exhaust air 286 x 586 mm 5 Counterflow heat exchanger 6 Exhaust air fan 7 Supply air fan 8 Control system 9 Bypass damper with actuator 10Extract air filter 11 Outdoor air filter 12 Condensate pan 13 Cable inlets 2 x M20, 8 x M16 14E lectric preheater battery (optional) with an optional heat insulation 15 Electric reheater battery (optional) 16 Outdoor air shut-off valve (optional) 17 Exhaust air shut-off valve (optional) 18 Control panel (optional) 19 Height adjustable feet 2 0 Condensate drain 21 Flexible connections top 22Flexible connections side Optional: Hot water preheater battery and hot water reheater battery for duct installation Figure: LG 1400 SR (right-hand version) S YS TE M VE NTE CH LG 1400 PAGE 4 Versions The compact VENTECH system ventilation unit LG 1400 is available in several different versions: • Right- or left-hand depending on the position of the supply air connection The unit may also be optionally equipped with the following additional functions: • See optional accessories • Weather proof design on request • With or without electrical preheater battery integrated into the compact ventilation unit for frost protection of the heat exchanger • With or without electrical reheater battery integrated into the compact ventilation unit LG 1400 version Left-hand version Right-hand version 08LG1400-L 08LG1400-R Item no. with integrated electrical preheater battery 08LG1400-L-V 08LG1400-R-V Item no. with integrated electrical reheater battery 08LG1400-L-N 08LG1400-R-N Item no. with integrated electrical pre and reheater battery 08LG1400-L-V-N 08LG1400-R-V-N Item no. optional with hot water reheater battery for external, assembly in a horizontal duct (type dep. on heating output requirement) 40LG080180 or 40LG080250 40LG080180 or 40LG080250 08AKE600200 and 07LM24A 08AKE600200 and 07LM24A Item no. without preheater and reheater battery Item no. shut-off valve with motor LM 24 A LG1400L 2 3 4 1 1 3 4 2 1 Outdoor air 2 Supply air 3 Extract air 4 Exhaust air LG 1400 S version Left-hand version Right-hand version 08LG1400-SL 08LG1400-SR Item no. with integrated electrical preheater battery 08LG1400-SL-V 08LG1400-SR-V Item no. with integrated electrical reheater battery 08LG1400-SL-N 08LG1400-SR-N 08LG1400-SL-V-N 08LG1400-SR-V-N 40LG080180 or 40LG080250 40LG080180 or 40LG080250 Item no. without preheater and reheater battery Item no. with integrated electrical pre and reheater battery Item no. optional with hot water reheater battery for external, assembly assembly in a horizontal duct (type dep. on heating output requirement) Item no. shut-off valve with motor LM 24 A 08AKE600200 and 07LM24A 08AKE600200 and 07LM24A LG1400SR LG1400SL 2 3 1 4 1 3 4 1 Outdoor air 2 Supply air 3 Extract air 4 Exhaust air 2 S YS TE M VE NTE CH LG 1400 PAGE 5 Technical specifications Dimensions: (W x H x D) 1445 x 1265 x 755 mm Housing in double-shell construction made of galvanized sheet steel, 50 mm heat insulation Air line connections: 4 x air line connection outdoor air / exhaust air / supply air / extract air (W x H) 200 x 596 mm (Type LG 1400) or air line connection outdoor air / exctract air (W x H) 200 x 596 mm (Type LG 1400 S) and air line connection exhaust air / supply air (W x H) 286 x 586 mm (Type LG 1400 S) Connection profile P30 Condensate connection with syphon and mechanical sealing device ø 40 mm at the bottom Electrical connection without preheater battery: 230 V/50 Hz/20 A Electrical connection with preheater battery: 400 V/50 Hz/25 A Degree of protection: IP 20 Permitted ambient temperature for the unit: + 5° C to + 40° C Weight without accessories: approx. 190 kg The characteristic curves shown are valid for the device design with an outdoor air filter of quality class F7, extract air filter of quality class G4. CHARACTERISTIC EXTERNAL PRESSURE INCREASE AIR VOLUME FLOW (for volume flow constant function) PRESSURE-VOLUME FLOW CHARACTERISTIC CURVE FOR LG 1400 WITH V CONSTANT FUNCTION ext. Pressure increase [Pa] COMFORT VENTILATION UNIT Air volume flow setting range: 350 to 1500 m³/h Stop operating condition: 6.5 W 900 Speed 1400 m3/h Speed 1000 m3/h Speed 800 m3/h Speed 500 m3/h 800 700 600 500 0,80 Wh/m3 400 0,65 Wh/m3 300 0,50 Wh/m3 200 0,45 Wh/m3 0,30 Wh/m3 100 The characteristic curves indicates the external pressure (pext.) available for the duct system. 0,20 Wh/m3 200 400 600 800 1200 1400 1600 TOTAL OUTPUT The SFP values shown [Wh/m³] take into account power consumption for both fans for supply air and extract air as well as the power consumption of the control system. PRESSURE-VOLUME FLOW CHARACTERISTIC CURVE FOR LG 1400 WITHOUT V CONSTANT FUNCTION 900 Speed 10 V Speed 8 V Speed 6 V Speed 4 V 800 700 600 500 0,80 Wh/m3 400 0,65 Wh/m3 300 0,50 Wh/m3 200 0,45 Wh/m3 100 0,30 Wh/m3 200 400 600 800 1000 1200 1400 1600 Air volume flow [m3/h] DEGREE OF RECOVERY IN ACCORDANCE WITH EN 308 (where extract air is 21 °C / 40% r.H.) Efficiency [%] FANS (factory setting) Air volume flow: Fan speed/low speed: 800 m³/h Fan speed/high speed: 1400 m³/h 1000 Air volume flow [m3/h] ext. Pressure increase [Pa] The technical specifications were measured by Lucerne Polytechnic – Engineering & Architecture, Centre for Integral Building Technology. 92 ŋ= 90 T ZUL - TAUL TABL - TAUL 88 86 84 82 80 TABL= + 21 °C and + 23 °C for 40 % r.H. - 10 °C TAUL= - 6 °C - 3 °C 300 400 500 600 700 800 900 1000 1100 1200 Air volume flow [m3/h] PASSIVE HOUSE CERTIFIED IN ACCORDANCE WITH PHI CRITERIA Non-residential building: Area of application: 350 to 1100 m³/h at an external pressure of 228 Pa Housing seal-tightness: external leakage 0,39 %, internal leakage 0,56 % Heat recovery rate: ŋHR, eff = 83 % Comfort criterion: Tsupply air= +16,5 °C bei Toutdoor air= -10 °C Flow efficiency: ŋel = 0,39 Wh/m³ Residential building: Area of application: 350 to 1200 m³/h at an external pressure of 198 Pa Housing seal-tightness: external leakage 0,36 %, internal leakage 0,52 % Heat recovery rate: ŋHR, eff = 82 % Comfort criterion: Tsupply air= +16,5 °C bei Toutdoor air= -10 °C Flow efficiency: ŋel = 0,38 Wh/m³ CERTIFIED ACCORDING TO EN13141-7:2010 Thermodynamic tests at air volume flow rates 344/922/1306 m³/h (at outdoor-temp. +7 °C (+1 x Ref. +2 °C), at extract air temp.+20 °C): Extract air side = 77 %/76 %/74 % and supply air side = 89 %/83 %/84 % Flow efficiency: ŋel = 0,15/0,24/0,39 Wh/m³ S YS TE M VE NTE CH LG 1400 PAGE 6 Technical specifications SOUND DATA (with an external pressure increase of 100/200 Pa) Supply air connecting pieces outdoor air connecting pieces Extract air connecting pieces Exhaust air connecting pieces Housing LWA [dB(A)] LW [dB] 8000 Hz 4000 Hz 2000 Hz 1000 Hz 500 Hz 250 Hz 125 Hz Lw [dB/Oct] 63 Hz LW [dB] 8000 Hz LWA [dB(A)] pt = 200 pa 4000 Hz 2000 Hz 1000 Hz 500 Hz 250 Hz 125 Hz 63 Hz Volume flow V [m³/h] pt = 100 pa Lw [dB/Oct] 500 52 51 65 49 47 45 36 24 66 58 58 57 71 55 53 51 42 30 72 64 800 59 56 70 56 53 52 43 32 71 63 65 62 76 62 59 58 49 38 77 69 1100 66 61 75 63 60 59 50 39 76 69 72 67 81 69 66 65 56 45 82 75 1400 72 67 80 70 66 65 57 47 82 75 78 73 86 76 72 71 63 53 88 81 500 52 47 60 34 32 26 13 6 61 52 58 53 66 40 38 32 19 12 67 58 800 56 50 61 41 38 31 20 11 63 53 62 56 67 47 44 38 26 17 69 59 1100 61 54 63 48 44 37 27 16 65 55 67 60 69 54 50 43 33 22 71 61 1400 65 58 64 55 50 43 34 21 68 58 71 64 70 61 56 49 40 27 74 64 500 50 45 60 37 34 26 13 5 61 52 56 51 66 43 40 32 19 11 67 58 800 55 50 62 44 40 32 20 11 63 54 61 56 68 50 46 38 26 17 69 60 1100 60 55 64 51 46 39 27 16 66 57 66 61 70 57 52 45 33 22 72 63 1400 65 60 66 58 52 45 35 22 69 60 71 66 72 64 58 51 41 28 75 66 500 56 57 63 50 48 49 39 26 65 57 62 63 69 56 54 55 45 32 71 63 800 60 59 68 56 54 54 45 33 70 63 66 65 75 62 60 60 51 39 76 69 1100 65 62 74 63 60 60 51 40 75 68 71 68 80 69 66 66 57 46 82 74 1400 70 65 80 69 66 65 58 47 81 74 76 71 86 75 72 71 64 53 87 80 500 46 45 41 31 33 32 22 21 50 39 52 51 47 37 39 38 28 27 56 45 800 50 49 49 40 41 39 29 22 55 46 56 55 55 46 47 45 35 28 61 52 1100 52 50 55 47 46 42 33 21 58 51 58 56 61 53 52 48 39 27 64 57 1400 60 58 66 60 56 52 43 25 69 62 66 64 72 66 62 58 49 31 75 68 Remark: Tolerances ± 2 dB for acoustic data Operation BYPASS FOR HEAT EXCHANGER The 100% bypass is controlled as a function of the preset room temperature, the measured extract air temperature and the outdoor air temperature. As a result the heat exchanger can be circumvented in the summer and the cool outdoor air blown out at night either directly or via the earth collector into the living space. CONTROL UNIT The ventilation units come equipped as standard with an integrated control and regulation system. The settings on the ventilation unit are carried out using an integrated web server, limited settings can also be carried out via the PICHLER handheld terminal or the colour touch display PI-HMI. In addition, the current operating status conditions and system values such as operating type, fan speed, temperatures, etc. are displayed on the PICHLER handheld terminal or on the control system. Signal lamps display the operation (green) and faults (flashing red) including as plain text displays. Auto matic or manual mode can be selected. OPTIONAL: BUILDING AUTOMATION – NETWORKING OPTIONS The Pichler-Air2-System offers multiple networking options as integration into a higher level building automation system. • Integratred webserver • Modbus RTU • Modbus TCP/IP • BACnet • LON The corresponding bus connection is activated/parameterized at the factory according to the customer's order. FUNCTIONS OF THE PICHLER CONTROL •P reheater battery, electric or PWW •A ir filter monitoring with pressure sensors (static or dynamic) •C ontinuously controlled heat/"cold" recovery via the counterflow heat exchanger • Preheater battery, electric and/or PWW • Air ventilation and humidification DIMENSIONS Colour touch display PI-HMI dimensions: (W x H x D) 80 x 121 x 42 mm Pichler handheld terminal dimensions: (W x H x D) 170 x 40 x 82 mm Connecting cable to the Pichler master: MPFK6S cable or similar flat cable (telephone cable) with 6 wires, max. length < 50 m REPLACEMENT AIR FILTER 1 piece extract air cassette filter G4: (W x H x D) 375 x 660 x 92 mm 1 piece outdoor air cassette filter F7: (W x H x D) 375 x 660 x 92 mm S YS TE M VE NTE CH LG 1400 Colour touch display PI-HMI and handheld terminal PAGE 7 Optimized operation with the Pichler-System-Optimizer Needs-based operation with air quality sensors Optional accessories • Pre-filter box / heater box • Hot water preheater battery (for external duct installation), with an optional heat insulation • Electric preheater battery, able to be connected to the outdoor air connecting pieces of the comfort ventilation unit. With an optional heat insulation. Compact electrical preheat module with infinitely adjustable 0 to 10 V regulation for anti-freeze protection of the counter-flow heat exchanger. Output: 6000 W • External outdoor air filter G4 as prefilter for the installation components such as the electric, hot water preheater battery, pre-filter box / heater box, brine battery, etc. • Electric reheater battery, able to be connected to the supply air connecting pieces of the comfort ventilation unit. Compact electrical reheat module with infinitely adjustable 0 to 10 V regulation for reheating the supply air. Output: 2000 W • Pressure sensors for constant volume flow and pressure regulation. •S hut-off valve •M oisture eliminator • Hot water reheater battery for reheating the supply air (for external duct installation) can be mounted directly on the supply air connecting pieces in the S version. Output: 9.7 kW Outdoor air temperature: 5° C Supply air temperature: 26° C Air volume flow: 1300 m³/h Water flow temperature: 55° C Water return temperature: 45° C Pressure loss: 22 Pa • Water cooling battery can be mounted directly on the supply air connecting pieces in the S version. Output: 8.1 kW Outdoor air temperature: 30° C Supply air temperature: 17.8° C Air volume flow: 1300 m³/h Water flow temperature: 6° C Water return temperature: 12° C Pressure loss: 49 Pa •P ICHLER control "demand-based fan regulation": For each area, 25 zones (50 volume flow regulators) can be integrated via a zone optimiser system developed in-house and divided into sections. If required, this system can be expanded to a maximum of 5 sections of up to 25 zones each, in other words a total of 125 zones (250 volume flow regulators). The current operating parameters of the volume flow regulators (e.g. flat position, current volume flows, etc.) are forwarded via a Modbus system to the central optimiser. This is used to calculate the optimal fan speed to in turn keep all flaps in the optimal point of operation. Advantages over constant pressure regulation: Considerably lower energy consumption by the fans, less flow noise thanks to regulated preliminary pressure in the duct system, and optimised regulation thanks to central control of all volume flow regulators. The "daisy chain" principle is applied to the bus cabling, minimising installation costs. • Filter monitoring by pressure sensors • 3-way motor control valve • Recirculation pump 230 V •E xternal supply air temperature (sensor for external batteries) • Outdoor air filter F9 for ventilation unit Optional accessories for needs-based operation Intelligent air quality sensors with a surface-mounted housing are available as optional accessories. The sensors help to control a needs based ventilation in living and working spaces. • Humidity sensor module (measuring range from 0 to 100 % relative humidity) • CO2 and humidity sensor module (measuring range from 0 to 2000 ppm and from 0 to 100 % relative humidity) THE AIR VOLUME FLOW CAN BE CONTROLLED VIA THE FOLLOWING SENSORS Needs-based operation via the CO2 and/or the humidity sensor module only functions in automatic mode. Additional functions regarding air quality and humidity control are set with the integrated webserver. The assignment of the fan speeds and the ppm values can be changed via the PC software. • CO2 sensor module (measuring range from 0 to 2000 ppm) Electrical connection of the sensors: 24 Vdc Temperature range of the sensors: - 20 to + 60 °C Humidity range of the sensors: 5 to 95 % relatvie humidity (not condensating) S YS TE M VE NTE CH LG 1400 PAGE 8 Data in accordance with EU Regulations 1253-2014 Page 1 of 2 Product fiche SystemPICHLER Ventech LG 1400 Ventech LG 1400 Produktdatenblatt System PICHLER System Ventech LG 1400 Two-way ventilation plant for non-residential use Speed control Other heat recovery system counterflow heat exchanger Model ID Type Drive type Type of heat recovery * Area of application ext. pressure [Pa] Point 4 Point 1 Point 3 Point 2 Point 5 Nominal air flow [m³/h] The apparatus complies with the Eco-design Directive inside the cross-hatched area The diagram applies to the reference coNominal air flow [m³/h]ext. pressure [Pa]Point 1Point 2Point 4Point 5Point 3nfiguration (fans, filters, heat exchangers) without assemblies not for ventilation (e.g. heating coils, louvre flaps, etc.). Additional loss of pressure must be taken into account when installing assemblies not for ventilation. Point 1 Internal specific fan power SVLint Thermal transmission ηt_nwla 1060 [W/(m³/s)] 80,50% [-] 75 [dB(A)] Enclosure sound power level LWA Nominal airflow qnom actual electrical input power Pel,ges 0,444 [m³/s] 1600 [m³/h] 0,94 [kW] vnom 1,80 [m/s] Nominal outside pressure ZUL ∆ps,ext ZUL 250 [Pa] Nominal outside pressure ABL ∆ps,ext ABL 250 [Pa] Internal pressure drop across ventilation components, ZUL ∆ps,int ZUL 329 [Pa] Internal pressure drop across ventilation components, ABL ∆ps,int ABL 272 [Pa] Internal pressure drop across non-ventilation components, ZUL ∆ps,add ZUL 0 [Pa] Internal pressure drop across non-ventilation components, ABL Fan efficiency, ZUL, at nominal external pressure loss and internal pressure loss across ventilation components ∆ps,add ABL ηfan ZUL 56,55 [%] Fan efficiency, ABL, at nominal external pressure loss and internal pressure loss across ventilation components External air leakage (at ±400 Pa) Internal air leakage (at 250 Pa) Energy class, ZUL-filter (F7) ** Energy class, ABL-filter (G4) ** ηfan ABL 56,92 [%] Airflow speed ZUL = supply air ABL = extract air Seite 1 von 2 Download from: www.pichlerluft.at 0 [Pa] <1 <1 960,4 588,2 [%] [%] [kWh] [kWh] S YS TE M VE NTE CH LG 1400 PAGE 9 Page 2 of 2 Point 2 Internal specific fan power SVLint ηt_nwla Thermal transmission Enclosure sound power level LWA Nominal airflow qnom 1070 [W/(m³/s)] 80,50% [-] 65 [dB(A)] Nominal external pressure, ZUL ∆ps,ext ZUL 0,444 [m³/s] 1600 [m³/h] 50 [Pa] Nominal external pressure, ABL Point 3 Internal specific fan power Thermal transmission Enclosure sound power level ∆ps,ext ABL 50 [Pa] SVLint ηt_nwla 568 [W/(m³/s)] 83,00% [-] LWA 59 [dB(A)] Nominal external pressure, ZUL ∆ps,ext ZUL 0,271 [m³/s] 975 [m³/h] 250 [Pa] Nominal external pressure, ABL Point 4 Internal specific fan power Thermal transmission ∆ps,ext ABL 250 [Pa] qnom Nominal airflow SVLint ηt_nwla 324 [W/(m³/s)] 88,50% [-] Enclosure sound power level LWA 55 [dB(A)] Nominal airflow qnom 0,097 [m³/s] 350 [m³/h] Nominal external pressure, ZUL ∆ps,ext ZUL 875 [Pa] Nominal external pressure, ABL Point 5 Internal specific fan power Thermal transmission Enclosure sound power level ∆ps,ext ABL 875 [Pa] SVLint ηt_nwla 265 [W/(m³/s)] 88,50% [-] 52 [dB(A)] LWA Nominal outside pressure ZUL ∆ps,ext ZUL 0,097 [m³/s] 350 [m³/h] 50 [Pa] Nominal outside pressure ABL ∆ps,ext ABL 50 [Pa] qnom Nominal airflow The ventilation unit complies with Eco-design Directive (EU Regulation 1253/2014) as required for 2018. Visual filter warning The ventilation unit has a visual warning to replace the filter. An error message will be displayed on the control panel when the set pressure difference is exceeded. WARNING: The plant will not work efficiently unless the filter is replaced regularly, causing power consumption to increase. Disposal Equipment that is no longer functional must be uninstalled by a specialist firm and properly disposed of at a suitable facility. The Electrical and Electronic Equipment Act (EAG-VO), implementing Community law Directives 202/95/EC (RoHS) and 2002/96/EC (WEEE Directive) applies. none * Types of heat recovery: Fluid circulation heat exchanger other heat recovery system ** The energy class is calculated based on the annual operating hours (8760 h) and average pressure loss (see table below for final pressure loss pursuant to ÖNORM EN 13053). Max. pressure drop across filter pursuant to ÖNORM EN 13053: Information based on the current state of knowledge of EU Regulation 1253/2014 Download from: www.pichlerluft.at Filter class Final pressure difference G1-G4 150 Pa M5-F7 200 Pa F8 - F9 300 Pa Responsible for the content: J. Pichler Gesellschaft m.b.H. Photos: Archiv J. Pichler Gesellschaft m.b.H. | Text: J. Pichler Gesellschaft m.b.H. All rights reserved | All photos are symbolic photos | Subject to change without notice | Version: 03/2016 db Seite 2 von 2 J. PICHLER Gesellschaft m.b.H. Systematic ventilation. Download from: www.pichlerluft.at [email protected] www.pichlerluft.at ÖSTERREICH 9021 KLAGENFURT AM WÖRTHERSEE Karlweg 5 T +43 (0)463 32769 F +43 (0)463 37548 ÖSTERREICH 1100 WIEN Doerenkampgasse 5 T +43 (0)1 6880988 F +43 (0)1 6880988-13 Sales offices in Slovenia and Serbia. Sales partners in Germany, Switzerland and Italy. S YS TE M VE NTE CH LG 1400 PAGE 10 VENTECH system LG 1400 and LG 1400 S at a glance! Fans: energy-saving radial fans with stateof-the-art EC motor technology with optional automatic constant volume flow control with an optional constant volume flow control or constant pressure control Counterflow heat exchanger: highly efficient heat recovery system with an air/air counterflow heat exchanger with an automatic 100% bypass Air volume flow: of 350 to 1500 m³/h with an external pressure of 100 to 600 Pa Filter: outdoor air cassette filter, quality category F7. Extract air cassette filter, quality category G4. Electric preheater battery: able to be connected to the outdoor air connecting piece of the comfort ventilation unit, with an optional heat insulation. Hot water reheater battery: for reheating the supply air (for external duct installation) Housing: made from zinc-plated steel plate with 50 mm thermal insulation Air connections: Left and right device design outdoor air / exhaust air / supply air / extract air (W x H) 200 x 596 mm (Type LG 1400) or air line connection outdoor air / extract air (W x H) 200 x 596 mm (Type LG 1400 S) and air line connection exhaust air / supply air (W x H) 286 x 586 mm (Type LG 1400 S) connecting profile P 30 Installation position: Free-standing installation Summer changeover: integrated 100% bypass damper with seal Optional: building automation – networking options: • Integratred webserver • Modbus RTU • Modbus TCP/IP • BACnet • LON The corresponding bus connection is activated/parameterized at the factory according to the customer's order. Electrical connection: using terminals Service – maintenance – initial startup OUR COMPACT VENTILATION UNIT LG 1400 SYSTEM VENTECH HAS BEEN EXTERNALLY INSPECTED BY • Lucerne Polytechnic – Engineering & Architecture • TÜV-AUSTRIA Services GmbH, Testing, Inspection and Certification Centre/Vienna OUR COMPACT VENTILATION UNIT LG 1400 SYSTEM VENTECH HAS BEEN CERTIFIED BY • Passivhausinstitut (Passive House Institute) Darmstadt • energie-cluster.ch, Declaration report by Lucerne Polytechnic Notice: Our product range includes units with a size up to 10,000 m³/h as well as comprehensive accessories. S YS TE M VE NTE CH LG 1400 Notes PAGE 11 S YS TE M VE NTE CH LG 1400 ErP 2018 PAGE 12 ErP 2018 Fulfils the requirements of the Ecodesign Directive, in accordance with EU Regulation 1253/2014. CZECH REPUBLIC Wien GERMANY SLOVAKIA ÖSTERREICH Klagenfurt HUNGARY ITALY Maribor SLOVENIA CROATIA BOSNIA AND HERZEGOVINA Beograd SERBIA Your partner/installer: Responsible for the content: J. Pichler Gesellschaft m.b.H. | Graphics and layout: WERK1 Photos: Ferdinand Neumüller, Archiv J. Pichler Gesellschaft m.b.H. | Text: J. Pichler Gesellschaft m.b.H. All rights reserved | All photos are symbolic photos | Subject to change without notice | Version: 07/2016 en/P J. PICHLER Gesellschaft m.b.H. Systematic ventilation. [email protected] www.pichlerluft.at AUSTRIA 9021 KLAGENFURT AM WÖRTHERSEE Karlweg 5 T +43 (0)463 32769 F +43 (0)463 37548 AUSTRIA 1100 WIEN Doerenkampgasse 5 T +43 (0)1 6880988 F +43 (0)1 6880988-13 Sales offices in Slovenia and Serbia. Sales partners in Germany, Switzerland and Italy.
Similar documents
Produktdatenblatt PICHLER System Ventech LG 1400
Produktdatenblatt PICHLER System Ventech LG 1400 PICHLER System Ventech LG 3200 Two-way ventilation plant for non-residential use Speed control Other heat recovery system counterflow heat exchanger
More informationProduct fiche_Pichler LG 750
Nominal air flow [m³/h] The apparatus complies with the Eco-design Directive inside the cross-hatched area. The diagram applies to the reference configuration (fans, filters, heat exchangers) witho...
More informationsystem ventech lg 150
a high efficiency heat recovery system with an air/air counterflow heat exchanger made of recyclable plastic with ca. 92% efficiency with an automatic 100 % bypass, with energy-saving radial fans w...
More information