Digital Trunked Mode

Transcription

Digital Trunked Mode
Digital System Overview
Communications Equipment Division
Professional Systems Business Group
Copyright © 2014 KENWOOD All rights reserved. May not be copied or reprinted without prior written approval .
Contents
1.
2.
3.
4.
5.
6.
What is NEXEDGE?
Technology Comparison
Business lineup
NEXEDGE Operating modes
Applications
Success stories
1. What is NEXEDGE ?
Presentation by TOP COMMUNICATIONS LTD, MONGOLIA
Copyright © 2014 KENWOOD All rights reserved. May not be copied or reprinted without prior written approval .
What is NEXEDGE / NXDN ?
•
•
Noun:
Spelling:
• Pronunciation:
•
NEX-EDGE
“néks·ej”
Definition: A Digital conventional and trunked radio system in
12.5kHz and 6.25kHz. Designed for local and wide area
communications. Capable of migrating with existing analog
systems also capable of IP Networking for wide are coverage.
4
What is NEXEDGE / NXDN ?
•
NEXEDGE
– Is a trademark name of JVC KENWOOD Corporation and a generic
term used when referring to KENWOOD‟s Digital Communication
System
• NXDN
– Is a trademark name of JVC KENWOOD Corporation and ICOM
Incorporated
– NXDN refers to the Digital Air Interface protocol used by both JVC
KENWOOD and ICOM
– NXDN Forum opened the NXDN technical standards to the industry
public in summer 2012.
5
TM
NEXEDGE and NXDN
TM
Kenwood
(NEXEDGE )
Icom
(IDAS)
Original application
Original application
TM
NXDNTM (Air interface, FDMA, 6.25kHz)
Supporting Basic Features ( voice call, etc.)
•
Kenwood and Icom agreed to promote NXDN CAI (Common Air Interface)
6
NEXEDGE and NXDN
NXDN- 33 Forum Members, 2014 April
http://www.nxdn-forum.com/members/index.html
7
Multimode / Easy Migration
•
NEXEDGE Equipment – Ready Today & Tomorrow
– FM Analog at 25 and 12.5 kHz Channels
– NXDN Digital Air Interface at 12.5 and 6.25 kHz. Channels
•
NEXEDGE provides a graceful migration path from analog to fully
digital or new installations
– NX and NXR equipment supports all modes
– NXR base use existing FM site equipment in FM and Digital Modes
– Shared Mode for Trunked operation
• NEXEDGE trunked traffic channels can be shared with existing external
analog conventional or LTR/MPT trunked logic controllers, as a transition
to NXDN trunking.
8
Multimode / Easy Migration
•
NX Portables & Mobiles support
–
–
–
–
–
–
•
FM Conventional Zones
FM LTR Zones
FM MPT Trunked
NXDN Conventional Zones
NXDN Trunked Zones
NEXEDGE Trunked IP Networks
NXR Base Stations and Repeaters support
–
–
–
–
–
FM Conventional Mode
External FM Conventional & MPT/LTR logic Controllers
NXDN Conventional Mode
NXDN Trunked Mode (Option)
NEXEDGE Multi-Site Trunked IP Network (Option)
9
Market Place
P25
TETRA
PDT
Market Approach
Public Safty
Military
Police/Highway Patrol
Fire
Ambulance
Utilitys
Airport
Railroad service
Bus/ School Bus
Road maintenance
Energy/Power
Prison
University Officer
Garbage truck
Business & Idustry
Airline
TAXI/ Customer pickup
Cash transport truck
Security equipment
Cargo delivery
Construction
Security
Food delivery
Trailer
Amusement park
Restaurant /Fast food
Convention center
Factory/Plant
Hotel/Casino
Shop assistant
Stadium
DMR
dPMR
NXDN
Market
10
2. Technology Comparison
Presentation by TOP COMMUNICATIONS LTD, MONGOLIA
Copyright © 2014 KENWOOD All rights reserved. May not be copied or reprinted without prior written approval .
Digital comparison
Common Air
Interface
Category
NXDN
P25 Phase 1
PMR
Conventional /
Trunking
PMR
Conventional /
Trunking
6.25k/12.5kHz
Channel Access
12.5kHz
Market
Manufacturer
dPMR
Conventio
nal /
Trunking
Tier II
PMR
Conventio
nal
TETRA
Tier III
PMR
Trunking
6.25kHz
PMR
Trunking
π/4-QPSK
6.25/12.5kHz
FDMA
Channel /
Carrier
Gross Bit Rate
License
Free
dPMR44
6
DMR
4Level FSK
Modulation Type
Channel
Bandwidth
dPMR
25kHz
TDMA
1
2
2/4
4800/ 9600bps
9600bps
4800 bps
9600bps
36 kbit
(4ch)
World wide
USA
World wide
World wide
World
wide
KENWOOD /
ICOM
Motorola /
Harris / EF
Johnson, etc
ICOM
MOTORO
LA /
Vertex /
Hytera /
Tait, etc.
Tait /
Hytera
Motorola /
EADS /
Sepura,
etc.
12
NEXEDGE Advantages
Compare to TETRA
•
Coverage
– Communication distance*
• TETRA : Mobile@8km/h, Suburb, 10W  11km
• TETRA : Portable@8km/h, Suburb, 1W  5.7km
Less than half of UHF NEXEDGE‟s Communication distance
Almost 1/4 of VHF NEXEDGE‟s Communication distance
•
Smaller number of Base station*
– Need 4-6 (16-18) sites to cover the area which NEXEDGE can cover
by 1site in UHF (VHF). This affects to the infrastructure cost.
•
VHF availability
– Easy to secure the frequency if customer currently use VHF system
•
Speech Quality / Clarity
* Based on JVC KENWOOD‟s simulation
13
NEXEDGE Advantages
Compare to MPT
•
Coverage
– NEXEDGE‟s coverage is 20% wider than FM analog
(will vary depends on the conditions)
•
Performance in Mobile
– NEXEDGETM performs better coverage especially when the radio
moves at high speed
•
Channel efficiency
– 6.25kHz mode of NEXEDGETM enables high channel efficiency
Example:
MPT
NEXEDGE
Ch 1 (12.5kHz)
Control Ch
Ch 1 (6.25kHz) Ch2 (6.25kHz)
Control Ch
Traffic Ch
Ch 2 (12.5kHz)
Traffic Ch
Ch 3 (6.25kHz) Ch 4 (6.25kHz)
Traffic Ch
Traffic Ch
14
NEXEDGE Advantages
Compare to DMR
•
Mixed Mode
– Enables easy budget migration
– DMR Solution (Scan) is slow response
• Pure Very Narrow solution
–
–
•
Coverage
–
•
DMR occupies 12.5kHz bandwidth in talk around mode.
6.25kHz dedicated channel for single user
6.25kHz bandwidth enables better coverage with better sensitivity than DMR
Multi-site Trunking IP network availability
15
Digital Audio Intelligibility
20% or Better Range than FM
– FM reception becomes increasingly noisier and intermittent with
distance
– Low BER improves reception in fringe areas
– Increases effective range as much as twenty percent over FM
Min Quality
12dB SINAD (FM)
3% BER (Digital)
Audio Quality
•
Digital
FM
Signal
Strong
Weak
16
Digital Sensitivity
Static Condition
NXDN(4800bps)
NXDN(9600bps)
1E-1
DMR
P25
TETRA
BER
1E-2
1E-3
NXDN is smaller
Bit Error Rate
1E-4
-125
-123
-121
-119
-117
-115
-113
-111
RF Input Level [dBm]
17
NXDN - Increased Range
•
NXDN Intelligible @ 2 x Distance of analog
20 km (32 mi.)
40 km (66.7 mi.)
Analog Audio
Red/Yellow: Excellent/ V.
Good
Green: Good
Blue: Noisy
Gray: Very Noisy/N.G.
NXDN Audio
( PESQ factored)
Green: Good
Blue: Noisy
18
FDMA and TDMA
•
TDMA (Time Division Multiple Access)
– Pros
• Better power consumption than FDMA
• Full duplex capability
– Cons
• Limited Communication distance due to the Guard Time
(TETRA: ~35km approx.)
• Repeater required (Multi-slot not available in Direct Mode)
• Not real physical 6.25kHz technology (6.25kHz equivalent)
Time
Time Slot
19
FDMA and TDMA
•
FDMA (Frequency Division Multiple Access)
– Pros
• Enables 2 party communication in direct mode
• Pure very narrow technology resolving Freq. resource issue
• Ordinal equipments can be reused (No linier AMP required)
– Cons
• Current consumption (same level as analog FM)
Time
Two Channels
Frequency
Bandwidth
20
TDMA Spectrum Efficiency
12.5 kHz channel
emission mask
12.5 kHz channel
emission mask
Time
Time
12.5 kHz
12.5 kHz
TDMA 1 voice
path @ CH
TDMA 2 voice
path @ CH
12.5 kHz
“efficiency”
Equivalent 6.25
kHz “efficiency”
Still occupies 12.5 kHz
channel band width
21
FDMA Spectrum Efficiency
12.5 kHz
6.25 kHz
6.25 kHz x 2
12.5 kHz channel
emission mask
12.5 kHz
6.25 kHz
Improve Interference
resistance
FDMA 1 voice
path @ CH
FDMA 1 voice
path @ CH
12.5 KHz
“efficiency”
6.25 KHz
“efficiency”
6.25 kHz
6.25 kHz
Two 6.25kHz spectrums can be
accommodated
22
FDMA Spectrum Efficiency
12.5 kHz
12.5 kHz
Mutual Interferences from/to
the neighboring licensees
Mutual Interferences from/to
the neighboring licensees
6.25 kHz
6.25 kHz
License Coordination must be carefully discussed region by region.
23
3. Business lineup
Presentation by TOP COMMUNICATIONS LTD, MONGOLIA
Copyright © 2014 KENWOOD All rights reserved. May not be copied or reprinted without prior written approval .
TM
NEXEDGE Product Line up
KENWOOD„s Digital Communication System NEXEDGE consist of:
TM
• NXR-700 / 800 VHF/UHF Repeater / Base Stations
• NXR-710 / 810 VHF/UHF Repeater / Base Stations
• NXR-900 / 901 800/900MHz Repeater / Base Stations
• NX-200 / 300 VHF/UHF Portables
• NX-220 / 320 VHF/UHF Portables
• NX-410 / 411 800/900MHz Portables
• NX-700 / 800 VHF/UHF Mobiles
• NX-720 / 820 VHF/UHF Mobiles
• NX-900 / 901 800/900MHz Mobile
25
NEXEDGE - 6.25kHz / FDMA solution
• Digital / Analog dual mode
• Digital Trunking mode with controller
• IP configuration capability
Mobile : NX-700/800/900/901
Portable : NX-200/300/400/401
NX-220/320
Repeater / Controller : NXR-700/800/900/901
Mobile : NX-720/820
Repeater : NXR-710/810
26
Software Packages
TM
The Kenwood NEXEDGE software suite comprises three
different software packages.
Configuration
•
•
•
•
•
•
KPG-109D – NXR-700/800 repeater programming software
KPG-129D – NXR-710/810 repeater programming software
KPG-111D – NX-200/300/700/800 radio programming software
KPG-141D – NX-220/320/720/820 radio programming software
KPG-111D – NX-200/300/700/800 radio programming software
KPG-110SM – System Manager software
Site management
•
•
KPG-149RM – Repeater monitor software
KPG-150AP – OTAP (Over the Air Programming) software
Not all software packages are required for all possible configurations.
Please see next slide for a list of combinations available.
27
Software Packages
1. Digital Conventional, without NXR repeater – required software
packages
• KPG-111D – portable and mobile radio programming software
• KPG-141D – portable and mobile radio programming software
2. Digital Conventional, with NXR repeater – required software
packages
• KPG-111D – High tier portable and mobile radio programming software
• KPG-141D – Mid tier portable and mobile radio programming software
• KPG-109D – NXR high tier repeater programming software
• KPG-129D – NXR mid tier repeater programming software
3.
•
•
•
Digital Trunking, single or multi site
KPG-109D – NXR repeater programming software
KPG-111D – NX-200/300/700/800 radio programming software
KPG-110SM – System Manager software
28
4. NEXEDGE Operating modes
Presentation by TOP COMMUNICATIONS LTD, MONGOLIA
Copyright © 2014 KENWOOD All rights reserved. May not be copied or reprinted without prior written approval .
Operating Modes
NEXEDGE systems support the following NXDN digital modes:
• Digital or analog conventional or mixed mode
– Radio to radio
– Radio via repeater
– Multi site conventional
•
Digital Trunked – single site, multi site, wide area IP networks
NEXEDGE equipment can support legacy analog modes for easy
migration from analog to digital.
30
Digital Conventional Mode
•
NEXEDGE Digital Conventional
– System sharing & private call capabilities beyond FM conventional
– Both FM analog & digital units can share the same RF channel!
Simplex Talk Around
Repeat Operation
31
Digital Conventional Mode
•
“Mixed” Channel Type
– When a Subscriber or a base receive incoming FM or NXDN calls
then talkback/repeat in the same mode received.
– FM & NXDN conventional units can share the same RF channel.
Mixed Mode
DIGITAL
DIGITAL
NXDN Mode
Analog
Analog
Analog Mode
32
Digital Conventional Mode
•
RAN (Radio Access Number)
– Community Repeater Capability 16 Users (range: 1-63)
– Like Analog CTCSS/DCS in FM
– Subs un-mute upon receipt of matching RAN & GID/UID call
•
1,000 GID‟s- Large group ID capacity for group calls.
– Partition IDs to organize talk groups per company, agency, division
and department
•
1,000 UID‟s- Large unit ID capacity for individual calls.
33
Conventional IP Network
•
Intersite calling within Conventional IP Network
– Conventional IP networking provides the ability to link 2 or more sites
via IP network infrastructure across geographic areas.
– IP Link in NXDN Conventional Mode
• Up to 48 sites link via multicast routing technology
• Supports Site to Site Roaming using repeater Beacon signal
Site 1
Site 2
34
Digital Trunked Mode
•
NEXEDGE Digital Trunking
–
–
–
–
Faster access / Less user operation than conventional systems
Increased capacity via trunked efficiency
Enhanced calling capabilities
System access privileges and improved security
Ethernet
Switch
35
Digital Trunked Mode
•
Fast System Access
– 320 ms access time / Automatic channel selection / No user
monitoring is required
•
Enhanced Efficiency
– Users share a pool of channels per site / Experiences less busies
during peak hours
• 1- 30 Channels @ site
– 1 CH Site: Digital trunked features (but no trunked CH pool)
– 2-30 CH site: Digital trunked features & trunking channel pool
efficiency
36
Digital Trunked Mode
•
3,000 GIDs- Large talk group capacity for fleet dispatch
operations.
• 3,000 UIDs- Large unit ID capacity for private unit-to-unit calling.
• Call Queuing
– Automatically stacks call requests when all traffic channels are busy
– Processes calls when a traffic channel is available
•
8 Priority Levels with Pre-emption
– Processes calls queue in order of priority.
– Pre-emption allocates a talk channel for priority personnel, dispatch
and emergency calls.
37
Digital Trunked Mode
•
Message Trunked Mode
– Users acquire uninterrupted exclusive channel use during each twoway conversation
– No blocking or interrupted two-way conversations
•
Transmission Trunked Mode
– Users acquire a channel at each push-to-talk; releases channel upon
release
– Less systems resources utilized
– Blocking/queues more probable during peak hours
38
Digital Trunked Mode
•
Priority Monitor ID 1 to 4
– Automatically collects subscriber radios to a high priority GID call
such as a dispatcher or supervisor even if on a low priority GID call
(between PTT‟s).
•
Late Entry
– Permits subscriber units to join a call already in progress after
powering on or entering system coverage.
•
Broadcast Call
– A one-way “all call” to a select talk group or all talk groups for
emergencies and incident response scenarios.
39
Multi-Site IP Networks
•
The NEXEDGE network option, bridges the gap between IP and
RF Digital Trunking Systems for wide area call capabilities up to
48 sites network.
Router
Ethernet
Switch
40
Multi-Site IP Networks
•
16 & 48 Site @ Network Capacity
– Multiple trunked sites linked together as one network
– 16 / 30 Sites @ Uni-cast network / 48 Sites @ Multi-cast network
– For campus, citywide, countywide, regional or inter-state
communications.
41
Multi-Site IP Networks
•
60,000 GID‟s & 60,000 UID‟s @ Network
– Large total capacity for shared networks and large fleets.
• Automatic Roaming
– Subscribers automatically search for the best accessible sites while
moving throughout a network.
– Use advanced control channel hunting algorithms, RF signal strength
(RSSI) and digital signal quality (BER) monitoring to make correct,
roaming and registration decisions.
•
ESN Validation
– Unique factory embedded ESN validated by the system to protect
against unauthorized access.
42
Over-the-Air User ID Alias
•
Over-the-Air Caller ID (UID)
– Calling units UID alphanumeric alias is sent over the air & displayed
in receiving units LCD
– No need to program every fleet alias in every radio
Caller ID Received: “MIKE”
Calling Unit UID 1267 alias: MIKE
Simplex Talk
Around
Repeat
Operation
Base Operation
43
Reliable Repeater Channels
A channel that can function as Control Channel or Traffic Channel
by conditions
• Failsoft Mode
– If trunking capability is disabled, the system reverts to conventional
operation so basic communications can continue.
• Control / Traffic Channel Switching
– Designates a Traffic Channel as a new Control Channel should the
original become disabled. Disabled Traffic Channels are automatically
removed from service.
•
Automatic Control Channel Rollover
– Enable the CC to cycle once per day at a certain Control Channel
Rollover Time to distribute power amp duty (trunking per site)
Ethernet Switch
Dual Functional Channel
Dual Functional Channel
CC
CC
Dual Functional Channel
CC
Dual Functional Channel
CC
44
Secure Communication
•
Casual Eavesdropping
– Analog Inversion Scrambler Built-in (FM mode)
– NXDN Digital Air Protocol – “Inherent level of security”
•
More Sophisticated Adversaries
– NXDN Digital Embedded Voice Scrambler (NXDN mode)
– Kenwood AES/DES Module Options (NXDN mode)
Top Secret
User: Government
KWD-AE21
AES Encryption
KWD-DE21
Secret
DES Encryption
User: Public Safety
Confidential
User: Industrial
Unclassified
NEXEDGE
Scrambler
NXDN Digital Scrambler
User: Commercial
45
Telephone Interconnect
•
•
Optional KTI-4 Offers Onsite or Offsite telephone interconnect
KTI-4 Supports IP connectivity
46
OTAP – Over the Air Programming
•
OTAP (KPG-150AP) allows the System Manager / Dealer /
Maintainer to reprogram a fleet / group of radios without the need
to physically connect a computer directly and program the radios
in the field.
47
Repeater monitoring
•
Repeater monitoring PC software (KPG-149RM) can be used to
notify a manager or supervisor via a LAN, once a problem with a
specific hardware has been detected. A log file output is available.
48
Basic Functions (supporting features)
Service
Conventional
Trunking
Single
Multi
Repeater
Direct
Group Call




Individual Call




Interconnect Call (PSTN Call)


-
-
Data Call (Group, Individual)


-
-
Short Data Call (on Control channel)


-
-
Simultaneous Data Call


-
-
Status Call




Emergency Call & Alert




Remote Stun




Late Entry




Registration


-
-
Roaming
-

-
-
Composite Control CH
(single CH)
(single CH)
-
-
Control CH Switching


-
-
Call Queuing


-
-
Priority Monitor


-
-
Authentication


-
-
Encryption




49
5. Applications
Presentation by TOP COMMUNICATIONS LTD, MONGOLIA
Copyright © 2014 KENWOOD All rights reserved. May not be copied or reprinted without prior written approval .
GPS Location Management
•
A location management with GPS data through NEXEDGE
Network
– KAS-10 PC software enables Virtual Radio IP Dispatch for NEXEDGE
Trunked Networks.
– Optional GPS microphone works for human positioning management.
KAS-10 AVL Dispatch PC software
51
Remote monitoring solution
•
Wireless still image transmission system employing NEXEDGE
digital transceivers.
•
Monitoring waterway, railway, construction site, motorway, traffic or
nature observation, etc.
Monitor Stations
Base Stations
KAS-11
Image Viewer
KVT-11
Image encoder
NX-700/800/900/901
NEXEDGE Transceiver
52
Remote monitoring solution
Marine-Earth Science
and Technology Agency have set up
the satellite data transmission system for
near real-time observation at their four
Automatic Climate Observation
System sites in Mongolia.
Our KVT-11/KAS-11 and NEXEDGE
system can transmit both of data and
picture with lower cost that satelite.
53
KSDP - Kenwood Solution Developers Program •
Worldwide Program to share the applications among NEXEDGE
customers. The program offers choices of applications to our
dealers and customers
•
3rd party developers platform to offer their solutions
54
Available applications
•
•
•
•
•
•
•
•
•
•
Voice Dispatching
AVL Dispatch, Fleet management/tracking with GPS
Messaging
Software consoles
Radio logging, Recording
Gateways
SCADA
Remote Monitoring and Controls
Digital Voting
Image transfer
etc.
55
KSDP - How to access On the B2B websites
Catalogs
56
Solution Developers Partners
And more in future…
57
Supporting tools for developer
• KPT-110SDK (Software Development Kit)
– The KPT-110SDK is the Software Development Kit for
supporting the development of Windows application software
which communicates with NEXEDGE system via NXIP
Specifications.
– KPT-110SDK provides Class Library and Sample Source
Code under NDA contract
Application
developed by 3rd
Party Vendor
Vendor implements
NXIP Protocol
KPT-110SDK
Windows XP/Vista/7
58
6. Success Stories
Presentation by TOP COMMUNICATIONS LTD, MONGOLIA
Copyright © 2014 KENWOOD All rights reserved. May not be copied or reprinted without prior written approval .
G8 Hokkaido Toyako Summit
Security management
• For the G8 Summit at Lake Toyako in
Japan, which was held in July 2008,
KENWOOD's NEXEDGE was chosen
to provide radio communications for
Japanese Government.
•
•
Ministry officials wanted to link three
sites - while allowing radio-to-radio
communications within each area.
Airport
Medium
Center
During the Summit the system
performed flawlessly and the Ministry
expressed its satisfaction.
64Km
21.5Km
80Km
Conference
Site (Hotel)
60
The Venetian, Las Vegas
Hospitality
•
•
•
Growth
–
With the addition of the Venezia Tower and the Palazzo the
management needed to add another 1,000 radios to the
2,000 already in use. This was something that could not be
achieved with their LTR system. Buying new frequencies
was too expensive. Also, because it is a resort the
Venetian‟s radios are used a great deal at night, when
support is not easily available, so reliability is especially
important.
Migration
–
Fortunately the Venetian found exactly what was needed in
NEXEDGE as it allowed them to migrate gracefully from
their 12-channel analog system (12.5kHz), doubling
capacity to 24 channels (6.25kHz). Being adaptable and
scalable were important factors in this decision, but so too
was cost. Other solutions would have meant purchasing
and deploying 3,000 radios at once – a major investment
and logistically problematic.
Benefits
–
Meanwhile, the Venetian‟s considerable investment in
analog radios, headsets, and batteries continues to serve
the staff in other departments. But as the migration
progresses, the digital benefits accrue. For example, in
fringe areas and elevators where signal strength was a
problem, voice quality is now crystal clear.
62
CN Tower, Toronto
Telecommunication network operator
•
Capacity
•
Solution
•
Cost efficient
– The CN Tower‟s new FDMA-based digital trunked
system – with its 6.25 kHz capability ensuring
clean, clear and defined signal propagation. This
was not previously possible with the LTR system.
– As the new system uses the same 450 MHz band,
migration was smooth and the CN Tower is a very
satisfied client. NEXEDGE has proved to be an
ideal solution for the tower and for MBC, which has
been serving the commercial SMR industry in
southern Ontario.
– Companies that had been using cellular are
strongly attracted by the cost-efficient wide-area
coverage made possible by NEXEDGE
technologies and economical IP networking, as
well as by the potential to exploit GPS and
messaging capabilities.
63
Ontario-Quebec SMR Network, Canada
OnQue Super wide area network system
Will expand over 60 site, 1200km coverage
64
Radio system information
Current Overview
• Ontario area: 24 site, 104 channels, 4300 subscribers
– Add more 6 sites in autumn 2012
•
Quebec area: 6 site, 20 channels,950 subscribers
Future plan
• Number of site
– Targeting in total 60 site
•
Coverage
– Will cover 1200km as a whole area
65
SP-PSA International Port, Vietnam
Port Operation
• Winning out over strong competition,
NEXEDGE was chosen by Singaporebased PSA International, the world's
second largest port operator, for its
new container operations in Vung Tau,
Vietnam.
•
Workers at this large facility are now
using over a hundred Kenwood radios
and further expansion is scheduled.
•
4ch VHF Trunking, 110 subscribers
66
Hessen Road Maintenance System, Germany
Motorway maintenance
• User: Building, Tunnel and service
vehicles of the motorway
maintenance area for summer and
winter services.
• The motorway maintenance area
is 50–60 km. For this distance
section operates approx. 35-50
vehicles.
• VHF Conventional IP network
• Switching from the existing
analogue to a digital system
67
TGS (Turkish Ground Services), Turkey
Airport Ground Services
• Air terminals and cargo depots provide
an ideal environment to demonstrate
the advantages of digital radios, and
TGS – which operates in six of
Turkey‟s busiest airports – has joined
the ranks of enthusiastic NEXEDGE
adopters.
•
Orgen, the local distributor, provided a
convincing argument for switching to
Kenwood‟s flagship digital radio
system from MPT trunking system,
and TGS is already planning to deploy
NEXEDGE at 35 sites by 2013.
68
Digital SMR Service, Malaysia
・
Analog trunked radio service for public and private network users in
800MHz were used in Malaysia in the past.
 Cause traffic congestion, missed calls, garbled messages, degraded
voice quality
・ Government decide to switch from 800MHz to UHF 410-430MHz for public
trunking network by Dec. 2015.
・ NEXEDGE main advantage is the ability to migrate from the current analog
system to wider, better and clearer service.
・
NX-Digital by Mal-Tel Communication Sdn Bhd
- Started building NEXEDGE trunked service in June 2011
- Already a few thousand subscribers by end 2012
- Targeting 50,000 subscriber units before Dec. 2015 for nationwide
69
More Success Stories
•
Airport
– Vnukovo International Airport, Moscow, Russia
• 2 site 6ch Trunking
•
Municipality Network
– City of Nice, France
• For Local police (w/GPS), Gabage collection
• UHF Trunking System
• Education
– Macquarie University, Sydney, Australia
• Conventional 2 Site UHF , 100 subscribers
•
SMR
– Vertel, Sydney, Australia
• 15 sites (Sydney 10, Melbourne 4, Perth 1 sites), 75ch Trunking
• 500 subscribers
70
More Success Stories
•
Private Utilities & Co-Ops
– WIN Energy, IN , USA
• 5 sites of NEXEDGE UHF trunking at 12.5 kHz, microwave, with
approximately 100 subscribers.
•
Hospitals
– Beaumont Hospital , USA
• 5 channel trunked sys. 6.25 kHz, 135 subscribers
•
Manufacturing
– US Steel , USA
• 3 site conventional non-networked UHF at 12.5 kHz with 50 subscribers
– NUCOR Steel , USA
• UHF Multi-site trunked syst., 18 channels, 6.25 kHz, over 800 subscribers
•
Hospitality/Gaming
– Win-River Casino , USA
• Multi-site UHF trunked system, UHF, 12.5 kHz
71
Presentation by TOP COMMUNICATIONS LTD, MONGOLIA
www.topcom.mn

Similar documents

nexedge - Kenwood

nexedge - Kenwood services using standard 10/100 Base-T Ethernet switches and routers. IPSEC VPN tunneling provides encryption and authentication for secure communications links within any IP network. 60,000 GID's &...

More information

ability - Kenwood

ability - Kenwood frequency in conventional Mixed Mode, continuing service to aging analog fleet radios as new digital radios are deployed. NEXEDGE radios, capable of both conventional analog and digital operation, ...

More information