platform shifting
Nobel Biocare is shifting gingival beauty to the next level
Nobel Biocare is shifting
gingival beauty to the next level
Platform Shifting is the latest
in Nobel Biocare’s offering
of individualized patient solutions, focused on emphasizing and promoting gingival
health and beauty.
Increases the volume
of soft tissue
Platform Shifting is the
concept of “stepping down”
the size of an implant platform to increase the volume
of soft tissue around the
implant platform during
implant treatment.
In practice, Platform Shifting
adapters convert regular (RP)
and wide (WP) platform
implants to narrow (NP) and
regular (RP) platforms
implants, respectively.
2
You can easily realize the
benefits of Platform Shifting
due to the fact that the
basic product assortment
is comprised of only two,
premanufactured adapters.
To these adapters, you will
employ the best abutments
on the market – Procera®
Abutment and Procera®
Esthetic Abutments Zirconia.
If you want to round out
your offering of individualized patient solutions, Platform Shifting is a must have
technique.
Platform Shifting Adapter is
currently not available in
the USA.
People once had to accept
the appearance and functionality of their teeth.
Now Nobel Biocare ensures
that everyone can have beautiful, fully functioning teeth.
In fact, we provide
the innovations in crowns,
bridges, laminates and
implants that enable you
to make that a reality.
Courtesy of Dr. Iñaki Gamborena & Mr. Iñigo Casares, Spain
Nobel Biocare is the only
company that offers you
a total solution so you can
do everything from start to
finish. As the world leader
in esthetic dentistry, we provide three core concepts:
“Now you have the opportunity to restore
teeth with the Platform Shifting concept.
It’s the way of restoring teeth with a more
predictable result than before, especially
• Easy Esthetics
• Soft Tissue Integration™
• Immediate Function™
on immediate implant treatments. When
The three concepts, when
used together, allow you to
create Beautiful Teeth Now™.
stabile with higher esthetic results.”
™
shifting to a narrower interface the space
increases and the soft tissue gets more
Dr Iñaki Gamborena
3
platform shifting in practice
Case from Dr. Iñaki Gamborena
Our patient, a 42-year-old woman, came to us
with a failing crown. Following bone and soft
tissue evaluation, we decided the appropriate
treatment solution would be to place a dental
implant under the Immediate Function™ protocol
and use the Platform Shifting concept to preserve
the maximal amount of soft tissue and bone.
After crown removal, no sound tooth structure was found
above free gingival margin
4
NobelReplace™ Tapered Groovy WP 5 × 13 mm implant
placement immediately after tooth extraction
Platform Shifting Adapter (WP-RP) and Procera® Esthetic
Abutment Zirconia RP placement
Abutment on Platform Shifting Adapter in alveolar socket
showing support offered to tissue architecture
Provisional crown placement
Ten-month, post-op x-ray showing stability of bone
at implant level
Ten-month, post-op picture of final Procera® Crown Alumina #21
product catalog
Art no Description
Abutment
interface
Implant
interface
34535
34536
34537
34538
34539
34540
34541
34542
34543
34544
34545
34546
34547
34548
34549
34550
34551
34552
34553
34554
34555
34556
34557
Procera® Esthetic Abutment Zirconia PS NP #1
Procera® Esthetic Abutment Zirconia PS NP #2
Procera® Esthetic Abutment Zirconia PS NP #3
Procera® Esthetic Abutment Zirconia PS NP #4
Procera® Esthetic Abutment Zirconia PS RP #5
Procera® Esthetic Abutment Zirconia PS RP #6
Procera® Esthetic Abutment Zirconia PS RP #7
Procera® Esthetic Abutment Zirconia PS RP #8
Procera® Esthetic Abutment Zirconia PS RP #9
Procera® Esthetic Abutment Zirconia PS RP #10
Procera® Esthetic Abutment Zirconia PS RP #11
Procera® Esthetic Abutment Zirconia PS RP #12
Impression Coping PS RP-NP ∅ 3.5
Impression Coping PS WP-RP ∅ 4.1
Healing Abutment PS RP-NP ∅ 3.5 × 5 mm
Healing Abutment PS WP-RP ∅ 4.1 × 5 mm
Adapter PS RP-NP
Adapter PS WP-RP
Abutment Screw PS RP-NP
Abutment Screw PS WP-RP
Procera® Wax-up Sleeve PS RP-NP
Implant Replica PS RP-NP
Implant Replica PS WP-RP
Procera® Abutment Zirconia Bmk Syst NP
Procera® Abutment Zirconia Bmk Syst RP
Platform Shifting products are currently not available in the USA.
www.nobelbiocare.com
5
platform shifting, clinical procedures
Procera® Abutment Zirconia
Indications
• Single- or multiple-tooth implant restorations
• Cement-retained
1. If applicable, remove healing abutment or temporization.
2. Ensure that the implant interface is free from any soft-tissue
or bone remnants. Place Adapter PS RP-NP into RP implant or
Adapter PS WP-RP into WP implant. Check that the lobes on
the adapter are fully engaged in the grooves of the implant.
Note: Ideally the Adapter PS should be placed the same day
as the implant placement, in order not to disturb the Soft Tissue
Integration™ and minimize the bone resorbtion.
Impression
3. Place the Impression Coping PS RP-NP or Impression
Coping PS WP-RP onto the implant. Use the Screwdriver
Unigrip™ and tighten the screw.
4. Take an implant level impression using the closed tray
technique as described in manual the NobelEsthetics™
Procedure & Products manual.
5. Connect suitable Healing Abutment PS RP-NP or Healing
Abutment PS WP-RP on top of the adapter using Screwdriver
Manual Unigrip™.
The illustrations above shows Platform Shifting
6
RP
to
NP
platform shifting, clinical procedures
Abutment connection
6. Healing Abutment PS.
7. Dispose of the abutment screw delivered together with the
Procera® Abutment Zirconia Bmk Syst. Use Abutment
Screw PS RP-NP (#34553) or Abutment Screw PS WP-RP
(#34554) instead.
Note: If preparation is needed, make sure that the thickness of the
ceramic material is at least 0.8 mm. This thickness limit is applicable
up to a height of 3 mm above implant level. Use the high-speed
turbine with diamond drills and copious water irrigation.
8. Place the Procera® Abutment Zirconia onto the implant.
Use the Screwdriver Unigrip™ and tighten the abutment screw.
Note: A radiograph can be help full to confirm accurate seating of
the abutment.
9. Tighten the abutment screw to 35 Ncm using the
Manual Torque Wrench Prosthetic and Screwdriver
Machine Unigrip™.
10. Continue prosthetic procedure as described in the
NobelEsthetics™ Procedure & Products manual.
7
platform shifting, clinical procedures
Procera® Esthetic Abutment Zirconia PS
Indications
• Single tooth or multiple implant restorations
• Single use only
• Cement-retained
1. If applicable, remove healing abutment or temporization
2. Ensure that the implant interface is free from any soft-tissue
or bone remnants. Place Adapter PS RP-NP into RP implant or
Adapter PS WP-RP into WP implant. Check that the lobes on
the adapter are fully engaged in the grooves of the implant.
Note: Ideally the Adapter PS should be placed the same day
as the implant placement, in order not to disturb the Soft Tissue
Integration™ and minimize the bone resorbtion.
Abutment connection
3. Try-in and modify the applicable Procera® Esthetic
Abutment Zirconia PS as described in the NobelEsthetics™
Procedure & Products manual.
Note: If preparation is needed, make sure that the thickness of the
ceramic material is at least 0.8 mm. This thickness limit is applicable
up to a height of 3 mm above implant level. Use the high-speed
turbine with diamond drills and copious water irrigation.
4. Place the Procera® Esthetic Abutment Zirconia PS onto
the implant. Use the Screwdriver Unigrip™ and tighten the
abutment screw.
Note: A radiograph can be help full to confirm accurate seating
of the abutment.
5. Tighten the abutment screw to 35 Ncm using the
Manual Torque Wrench Prosthetic and Screwdriver
Machine Unigrip™.
6. Continue prosthetic procedure as described in the
NobelEsthetics™ Procedure & Products manual.
The illustrations above shows Platform Shifting
8
RP
to
NP
platform shifting, dental laboratory procedures
Procera® Abutment Zirconia
Indications
• Single tooth or multiple implant restorations
• Cement-retained
1. Model
• An implant level impression is received with an Impression
Coping PS.
• Confirm the position of the implant level impression coping
and Implant Replica PS assembly in the impression.
• Pour and fabricate a soft tissue master model.
2a. Regarding Procera® Abutment Wax-up
• Create the abutment in a pattern resin or a hard wax. Use a
temporary component as a foundation for the abutment pattern.
– For Implant Replica PS WP-RP,
use Temporary Abutment Plastic Engaging Bmk
Abutment Screw PS WP-RP.
– For Implant Replica PS RP-NP,
use Procera® Wax-up Sleeve PS
Screw PS RP-NP.
RP-NP
RP
with
with Abutment
• You must respect certain dimensions in the waxed framework
depending on which Procera® product you wish to fabricate:
– For ceramic abutments NP,
maximum dimensions are 4 mm × 12 mm
radius × height (r × h).
– For ceramic abutments RP/WP,
maximum dimensions are 5 mm × 15 mm (r × h).
2b. Regarding Procera® Abutment CAD
To facilitate correct abutment angulations and measurements,
insert a T-bar into the replica. It is contained in the Procera®
Abutment 3D CAD Kit and will help you to feed correct data
into the Procera® Software 3D CAD Design application.
9
platform shifting, dental laboratory procedures
3. Scanning
Note that the scanning procedure is only necessary for Procera®
Abutment Wax-up.
• Open the Procera® Software and follow the instructions in the
tutorial for:
– Creating an open order.
• Scan the die using the Procera® Scanner according to the
tutorial found within the software.
Note: Use the ordinary BmkSyst Lab Screw to attach the wax-up
pattern in the implant platform replica
• Follow instructions in the tutorial for:
– Using the Procera® Software CAD Design Application.
– Dispatching an order.
4. Concluding Procedure
After delivery of the Procera® Abutment from the Nobel Biocare
production facility:
Ceramic Abutments
• If necessary, make minor adjustments with diamond bur
or flex disc with fine grit size under low pressure and with
copious water irrigation.
• When designing/preparing Procera® Abutment Zirconia,
make sure that the thickness of the ceramic material is at
least 0.8 mm. This thickness limit is applicable up to a height
of 3 mm above implant level.
• Sandblast using two to four bars of pressure utilizing
110 µm – 250 µm aluminum oxide, at an approximate
distance of 10 mm.
• Clean in an ultrasonic unit.
10
platform shifting, clinical procedures
Cleaning & Sterilization
Sterile Components
The devices delivered sterile have a “Sterile” marking on the
label. Opened packages of components that have never entered
the oral cavity of a patient may be cleaned and steam autoclaved
again following the established procedures of your local hospital
or clinic for similar products.
Non-Sterile Components
Modified abutments and restorations from a dental laboratory
are cleaned and sterilized (if indicated) according to generally
accepted procedures for dental laboratory work. Procera® Esthetic
Abutment Selection Kit and Procera® Esthetic Abutments are delivered non-sterile. The Procera® Esthetic Abutments and the Procera®
Esthetic Abutment Selection Kit can be autoclaved according to
standard routines either as separate units or when the abutments are mounted in the kit.
Instruments
Instruments are to be cleaned and sterilized before intra-oral use
in compliance with established routines at the hospital/clinic.
Manual Torque Wrench Prosthetic
135˚C/276˚F
Clean the parts thoroughly. Allow them to dry completely.
Sterilize the instrument using a steam autoclave at 135° C for
minimum hold time of 5 minutes or according to recommendations from the manufacturer of the autoclave.
5 mm
11
v 7:2
our qualifications are
Achievements
• Inheritors and developers of the
work of Professor Brånemark –
founder of modern implantology.
World leader in the field
• Providers of the most comprehensive
and flexible crown, bridge and
implant solutions in the world
• Creators of biocompatible material
TiUnite® for optimal osseointegration,
Immediate Function™ and Soft Tissue
Integration™
• Inventors of unique Procera®
System and CAD/CAM dentistry
• FDA cleared for Teeth-In-An-Hour™
in 2004
Quality and Environment
• Certified according to ISO
13485:2003 and ISO 14001:2004
• Between 2003–2006, passed a total
of 86 external assessments “with
excellence”. Zero non-conformities
in 2004 FDA inspections of Nobel
Biocare production units in Göteborg,
Karlskoga and Stockholm
Research
• More clinical studies on immediate
or early loading than all other
competitors combined
(Medline December 2006)
• More prospective clinical studies
with at least 5-year follow-up than
all other competitors combined
(Berglund et al 2002)
Support
• Over 300,000 dental professionals
trained in 40 countries during 2006
• Nobel Biocare sales organizations
with local Nobel Biocare staff in
more than 34 countries
• FDA cleared for Immediate Function™
(except 3.0 and Zygoma)
• Formal collaboration with over
50 academic institutions and
600 independent scientists
around the world
AUSTRALIA
Nobel Biocare Australia Pty Ltd
Phone: +61 2 9412 11 44
HONG KONG
Nobel Biocare Asia Ltd
Phone: +(852) 2-845-1266/14 12
POLAND
Nobel Biocare Polska Sp z oo
Phone: +48 22 874 59 44
BELGIUM
Nobel Biocare Benelux NV
Phone: +32 2 467 41 70
INDIA
Nobel Biocare India Pvt Ltd
Phone: +91 22 5551 9999
SOUTH AFRICA
Nobel Biocare South Africa Pty Ltd
Phone: +27 11 802 0112
CANADA
Nobel Biocare Canada Inc
Phone: +1-905-762-3500
Toll free: +1-800-263-4017
LITHUANIA
Nobel Biocare UAB
Phone: +370 5 268 3448
SWEDEN
Nobel Biocare AB
Phone: +46 31 335 49 00
NETHERLANDS
Nobel Biocare Benelux BV
Phone: +31 30 635 49 49
UNITED KINGDOM
Nobel Biocare UK Ltd
Phone: +44 (0) 1895 430 650
NORWAY
Nobel Biocare Norge AS
Phone: + 47 22 24 98 30
USA
Nobel Biocare USA LLC
Phone: +1-714-282-4800
Toll free: +1-800-993-8100
Cust. support: +1-800-322-5001
DENMARK
Nobel Biocare Danmark A/S
Phone: +45 39 40 48 46
FINLAND
Nobel Biocare Suomi Oy
Phone: + 358 9 343 69 70
for details of our patient program visit www.nobelsmile.com
Nobel Biocare cares about the
environment and all production
units are certified according to
Environmental Management
System ISO 14001
www.nobelbiocare.com
18674 A GB 0703 Printed in Sweden © Nobel Biocare Services AG, 2007.
Nobel Biocare, the Nobel Biocare logotype and all other trademarks used in this document are, if nothing else is stated or is evident from the context in a certain case, trademarks of the Nobel Biocare group.
your security