CATALOG Chillers
Transcription
CATALOG Chillers
CATALOG Chillers 2014 An InternatIonaL saLes network 2 NORD-PASDE-CALAIS BASSENORMANDIE PICARDIE HAUTENORMANDIE Tillières-sur-Avre ILE-DE-FRANCE Guyancourt CHAMPAGNEARDENNE LORRAINE BRETAGNE PAYS-DELOIRE CENTRE BOURGOGNE FRANCHECOMTE POITOUCHARENTE Pons LIMOUSIN AUVERGNE RHÔNESALPES AQUITAINE MIDIPYRENEES PROVENCE-ALPESCÔTE-D'AZUR LANGUEDOCROUSSILLON CORSE Commercial: [email protected] Aftersales: 33 (0)1 39 44 65 79 Airwell France SAS 1 bis avenue du 8 mai 1945 78280 Guyancourt - FRANCE Tel. +33 (0)1 39 44 78 00 Fax +33 (0)1 39 44 11 55 3 Our History 1947-1950 Founded in 1947, Airwell Group is one of the globally leading manufacturers and distributors of air conditioners and central air conditioning systems. The company has production facilities and marketing subsidiaries worldwide. Paul Wallet founded “L’Air Conditionné entreprise” which later became the core of Airwell Group. 1950 The Company developed and began the mass production of the first window unit, to offer exceptional climate conditions, mainly dedicated to european and African markets. 2008 The Group reinforced its position in the American continent by acquiring the Fedders Residential Business (USA). exPertise Over 60 years of experience in the design, development and production of residential, commercial and industrial applications make Airwell Group an indispensable actor on the european market. References are numerous in France and internationally and concern all sectors of activity including many hospitals (operating rooms, white rooms...) industrial sites, energyefficient office buildings, hotels, and also under naval board. Our sales department will be able to illustrate our references according to your requests. 1970 Airwell developed a split system unit by splitting its core window unit in two parts, and was the first to produce wall split systems in europe. 1975 Airwell entered the commercial and industrial markets with large cooling capacity for packaged air and water-cooled systems. 1979 After the two oil crises in the 70s Airwell developed the first high-efficiency air to water heatpump to be connected to existing oil boilers in residential housing for oil energy saving. 1982 Airwell designed and produced the first european wall split system range including electronic remote control, a high technology cross-flow fan for low noise levels, and rotary compressors. 1993/1996 The Group grew with the acquisition of Spanish, Italian, German and French distribution companies, as well as the factory in Tillieres. 1998/2001 The Group strengthened its position by acquiring production facilities in China, France (Wesper) and Italy, and extended its distribution network in Argentina and Turkey. 2004/2006 In order to accentuate its position in the market, the Group opened an office in Russia and acquired Polenz Klimatechnik in Germany. 4 Table of contents AIR COOLED CHILLERS Puissance Kw p. 10 à 82 Cooling mode only AQAL AQAL AQCL EQPLU EQPL EQPLA EQUL EQUL PF EQSL EQSLA 25/40 45/125 25-130 128.1 / 204.2 215 / 830 106 / 860 21 / 260 21 / 290 300 / 1310 90 / 1510 Cooling only Cooling only Cooling only Cooling only Cooling only Cooling only Cooling only Cooling only Cooling only Cooling only Scroll Scroll Scroll Ductable Scroll Scroll Scroll Class A Scroll Scroll Ductable Screw Screw CLASS A 25 / 37 46 / 122 25 / 125 128 / 200 210 / 808 210 / 808 20 / 260 20 / 260 299 / 1310 283 / 1510 10 12 14 16 18 22 28 32 36 40 Heat pump Heat pump Heat pump Heat pump Heat pump Heat pump Heat pump Heat pump Scroll Inverter Scroll Scroll Scroll Ductable Scroll Scroll Scroll Ductable Screw 2,4 / 18 25 / 37 46 / 122 25 / 80 128 / 830 21 / 261 21 / 255 201 / 1098 44 46 48 50 52 56 62 66 Free cooling Free cooling Free cooling Free cooling Scroll Scroll Ductable Scroll Screw Class A 19 / 258 21 / 260 64 / 313 288 / 1445 70 76 80 84 Heat pump mode MQHD AQAH AQAH AQCH EQPH EQUH EQUH PF EQSH 06 /018 25/40 45/125 25-80 128 / 830 21 / 260 22 / 290 200 / 1090 Free Cooling mode EQMF EQMF PF EQEF EQSFA 21 / 260 22 / 290 60 / 300 290 / 1450 WATER COOLED CHILLERS p.90 à 128 Cooling mode only EWNL EWNL RC EWML EWML RC EWSL K EWSL A EWSL A+ 06 / 30 06 / 30 27 / 570 27 / 570 190 / 660 410 / 1610 620 / 1180 Cooling only Cooling only Cooling only Cooling only Cooling only Cooling only Cooling only Scroll Scroll Remote condenser Scroll Scroll Remote condenser Screw Screw Class A Screw Class A+ 5 / 30 5 / 30 29 / 670 29 / 670 186 / 655 406 / 1604 620 / 1160 90 94 96 102 104 106 108 Heat pump Heat pump Heat pump Heat pump Heat pump on water side Heat pump on water side Scroll Scroll Remote condenser Scroll Scroll Remote condenser Scroll Screw 5 / 30 5 / 30 27 / 670 27 / 360 28 / 655 406 / 1604 110 112 114 120 122 128 Heat pump mode EWNH 06 / 30 EWNH RC 06 / 30 EWMH 27 / 570 EWMH RC 27 / 380 EWMH W 27 / 570 EWSH W 410 / 1610 AIR COOLED CONDENSING UNIT p. 134 CDN Air Cooled condensing units 18 / 83 AIR COOLED CONDENSERS / DRY COOLERS 134 p. 138 à 150 AIR COOLED CONDENSERS ACCL ACCH ACCL PF ACCH PF 11 / 280 11 / 280 11 / 144 11 / 144 For Cooling only For Reversible For Cooling only For Reversible 14 / 280 14 / 144 Axial Ventilator Plug Fans Ductable Ductable 12 / 307 12 / 307 12 / 155 12 / 155 138 138 142 142 Ductable 08 / 172 08 / 89 146 150 DRY COOLERS DC DC PF Generals Conditions 155 5 Chillers Range - Large - Complete - Flexible AIR COOLED CHILLERS FREE COOLING COOLING ONLY Puiss. KW 5 20 125 AQAL Mono-Circuit - Bi compressor Scroll - Axial AQCL 1 Circuit - Bi compressor Scroll - Centrifuge 300 400 500 600 EQPL 2, 3 an 4 circuits - Scroll compressors - Axial EQPLA 2, 3 et 4 circuits- Scroll compressorsl - Axial - CLASS A 1 and 2 circuits- Scroll compressors - Axial and plug fan- Ductable EQUL PF 700 R410A R410A EQSL Bi-circuits - Screw compressor - Axial EQSL A Bi-circuits - Screw compressor - Axial - Class A EQMF 1 and 2 circuits- Scroll compressor - Axial - Freecooling EQMF PF 1 and 2 circuits- compresseur Scroll - plug fan-Freecooling Ductable R410A R410A 1 et 2 circuits- Scroll compressor - Axial -Freecooling EQEF EQSFA REVERSIBLE 200 R410A Bi-circuits - Screw compressors - Axial - Class A MQHD 1 circuit- Scroll Inverter compressor- Axial R410A AQAH Mono-Circuit - Bi Scroll compressor - Axial R410A AQCH 1 Circuit - Bi Scroll compressor - Ductable EQPH 2, 3 and 4 circuits- Scroll compressor- Axial EQUH PF 1 and 2 circuits- Scroll compressor - Axial and plug fan- Gainables EQSH R410A Bi-circuits - Screw compressor - Axial WATER COOLED CHILLER COOLING ONLY Puiss. KW 5 20 125 EWNL 1 circuit-comp Scroll EWNL RC 2 circuits-comp Scroll remote condenser 200 300 400 500 600 R410A R410A EWML 1 and 2 circuits - Scroll compressor R410A EWML RC 1 and 2 circuits - Scroll compressor - remote condenseur R410A EWSL K Mono-circuit -Screw compressor EWSLA Bi-circuit - Screw compressor - Classe EWSLA+ REVERSIBLE 700 Bi-circuit - Screw com EWNH 1 circuit-comp Scroll EWNH RC 1 circuit-comp Scroll remote condenser R410A R410A EWMH 1 and 2 circuits - Scroll compressor -Reversible refrigérant side R410A EWMH RC 1 et 2 circuits - compresseurs Scroll - Reversible coté réfrigérant- condenseur déporté R410A EWMH W 1 and 2 circuits - Scroll compressor - reversible water side R410A EWSH W 2 circuits - Screw compressor- revers AIR COOLED CONDENSERS / DRY COOLERS ACCL ACCH Air ccooled condenser - Axial ACCL ACCH PF Air ccooled condenser - Plug fan - Gainable DC Dry cooler - Axial DC PF Dry cooler - Plug fan - Gainable R410A 6 R410A 0 MODERN TECHNOLOGIES AND HIGH EFFICIENCIES 800700 900800 1000 900 R410A R410A R410A R410A 1100 1000 1200 1300 1100 1400 1200 1500 1300 1600 1400 1500 1600 Scroll Class A 0 Vis / Screw "inteligent" control Micro Channel condenser R410A R410A Electronic expansion 800700 900800 1000 900 1100 1000 1200 1300 1100 1400 1200 1500 1300 1600 1400 1500 1600 Plug fan with EC motor R410A R410A ressor A - Classe A High efficiency heat exchangers mpressor cuit - Screw - Classe compressor A+ - Classe A+ Our company is engaged in a permanent research of energy saving on and all around his product lines. This logo is the witness of this voluntary gait in terms of: R410A R410A Engagement - Efficiency - Energy R410A mpressorsible waterreversible side water side Full units are tested Powerfull test facilities, each unit is individually tested (hydraulic and electrical connection. Our refrigerants are ozone friendly Our chillers range is Eurovent certified 7 R410A 8 Air Cooled Chiller 9 Air Cooled Chiller | AQAL 25/40 cooling only NEWS Scroll R410A Cooling Capacity from 25 to 37 KW Size = 4 Refrigerant : R410A EER up to 2.97 ESSEER up to 4 Main Functions: available with one cooling circuit Tandem scroll per refrigerant circuit Extented working limits STD operating up to +7°C external T Available Versions: Main accessories and options ow sound level Standard L High temperature operation up to 50°C (STD) Return or leaving water temperature control With or without Hydraulic kit Code Product Advantages andem scroll compressors per circuit for a highest efficiency at partial load T High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 L/KW Low footprint Easy maintenance Low water pressure drop Set point compensation as STD Night mode (extra low sound level) std ON OFF Remote Water flow switch factory mounted STD Water filter STD (not mounted) Phase monitor STD Few options, maximum features as STD Closed cabinet with inside the thermodynamic and hydraulic parts WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External Max air temperature External Min air temperature +5°C / +18°C +2°C +50°C -10°C 10 HP/BP Manometers Kit interface modbus Low temperature kit (-10°C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 1 pump medium pressure Rubber antivibration pad Water level pressure switch External water tank preliminary data COOLING ONLY VERSION AQAL 25 30 35 40 25,3 26,9 35,8 36,8 8,6 9,3 13,2 13,6 Total EER 100% * * 2,94 2,88 2,71 2,70 ESEER * * 3,78 3,77 3,88 3,71 Direct Direct Direct Direct Nominal current A 15,1 16,3 24 24 Maximum operating current A 18,2 21 29,6 30 61 75 115 118 1 1 1 1 8,2 8,4 9,1 9,2 1 2 2 2 Scroll Scroll Scroll Scroll 0/50/100 0/50/100 0/50/100 0/50/100 40 70 70 70 AQUALOGIC II Cooling Capacity kW Power input kW Class Electrical power 400V/3ph/50 Hz Start up type Inrush current A REFRIGERANT Type Quantity cooling cicuits Charge kg R410A COMPRESSEURS Quantity cooling cicuits Type N° capactity steps % Cranckcrease heater W EVAPORATEUR Quantity 1 1 1 1 Plaques Plaques Plaques Plaques 4,3 4,6 6,1 6,3 37 22 37 37 1,78 2,55 2,55 2,55 30 30 30 30 1 1 1 1 2,4 2,4 2,8 2,8 Row quantity 2 2 2 2 Quantity 1 1 1 1 13000 13000 16000 16000 930 930 650 650 940 940 930 930 1 1 1 1 Inlet Diameter pouces 1"1/2 1"1/2 1"1/2 1"1/2 Outlet diameter pouces 1"1/2 1"1/2 1"1/2 1"1/2 Length mm 1000 1000 1000 1000 Width mm 1000 1000 1000 1000 height mm 1983 1983 1983 1983 280 310 320 320 75 75 76 76 Type Water flow rate m³/h Water pressure drop kPa Water volume l Antifreeze heater W Coil Quantity Exchange surface m2 Fan motors Air flow m³/h Rotation speed tr/mn power input (unitary) W Pumps Quantity Power input Kw Available static pressure Kpa Hydraulic connexion Type Dimensions Weight Opérating weight kg Sound Level Sound level of power (*) dB(A) Sound pressure level (1) dB(A) (1)Sound pressure level at 10 m. ISO standard 3744 with parallépiped form (*)Following Eurovent standard. (**) Followingt Eurovent 14511 11 Air Cooled Chiller | AQAL 45/125 NEWS cooling only Scroll R410A ooling Capacity from 46 to 122 KW C Size = 7 Refrigerant : R410A EER up to 3 ESSEER up to 4 Main Functions: available with one cooling circuit Tandem scroll per refrigerant circuit Extented working limits STD operating up to +7°C external T Available Versions: Main accessories and options Low sound level Standard High temperature operation up to 50°C Return or leaving water temperature control Code Product Advantages andem scroll compressors per circuit for a highest efficiency at partial load T High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 L/KW Low footprint Easy maintenance Low water pressure drop Set point compensation as STD Night mode (extra low sound level) std ON OFF Remote Water flow switch factory mounted STD Water filter STD (not mounted) Phase monitor STD Few options, maximum features as STD WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External Max air temperature External Min air temperature +5°C / +18°C +2°C +50°C -10°C 12 HP/BP Manometers Kit interface modbus Low temperature kit (-10°C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 1 pump medium pressure Complete Hydraulic kit 2 pumps medium pressure Rubber antivibration pad Water level pressure switch Water tank COOLING ONLY VERSION AQAL 45 55 65 75 90 105 125 AQUALOGIC II Cooling Capacity kW 49,1 56 69,1 75,1 96 111,5 128 Power input kW 16,9 19,67 22,1 24,3 34,36 38,06 46,4 Total EER 100% * * 2,91 2,85 3,13 3,1 2,79 2,93 2,76 ESEER * * 4,06 4,08 4,2 4,17 4,01 4,04 4,02 B C A A C B C Class Electrical power 400V/3ph/50 Hz Start up type Nominal current A Maximum operating current A Inrush current A Direct Direct Direct Direct Direct Direct Direct 30 35 42 47 62 69 84 34 39 52 57 67 77 92 126 134 195 201 250 300 330 1 1 1 1 1 1 1 14 14,3 18,9 19,3 22,0 32,3 33 2 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Scroll REFRIGERANT Type Quantity cooling cicuits Charge kg R410A COMPRESSEURS Quantity cooling cicuits Type N° capactity steps % Cranckcrease heater W 0/50/100 0/40/60/100 0/40/60/100 0/45/55/100 0/45/55/100 0/38/62/100 0/33/67/100 2*90 2*90 2*90 2*90 90/120 90/140 90/140 EVAPORATEUR Quantity Type Water flow rate m³/h Water pressure drop kPa Water volume l Antifreeze heater W 1 1 1 1 1 1 1 Plaques Plaques Plaques Plaques Plaques Plaques Plaques 8 9,1 11,3 12,3 15,7 18,2 20,9 27 35 28 33 26 34 45 4,1 4,1 6,1 6,1 10,8 10,8 10,8 30 30 2*30 2*30 2,30 2*30 2*30, Coil Quantity Exchange surface m2 Row quantity 1 1 2 2 2 2 2 4,2 4,2 5,55 5,55 6,4 6,4 6,4 2 2 2 2 2 3 3 Fan motors Quantity Air flow m³/h Rotation speed tr/mn power input (unitary) W 1 1 2 2 2 2 2 22500 22500 30000 30000 42000 42000 42000 900 900 650 650 860 860 860 2100 2100 930 930 2100 2100 2100 Pumps Quantity OPTION 1 ou 2 POMPES Power input Kw OPTION 1 ou 2 POMPES Available static pressure Kpa OPTION 1 ou 2 POMPES Hydraulic connexion Type Male GAS Threaded Inlet Diameter pouces 2" 2" 2" 2" 2"1/2 2"1/2 2"1/2 Outlet diameter pouces 2" 2" 2" 2" 2"1/2 2"1/2 2"1/2 Dimensions Length mm 2180 2180 2180 2180 2180 2180 2180 Width mm 1160 1160 1160 1160 1160 1160 1160 height mm 1986 1986 1986 1986 2286 2286 2286 490 490 560 560 870 980 1000 79 79 79 79 82 82 82 Weight Opérating weight kg Sound Level Niveau de puissance sonore (*) dB(A) (*)Following Eurovent standard. (**) Followingt Eurovent 14511 13 Air Cooled Chiller | AQCL 25-130 cooling only Scroll Ductable ❯❯Cooling capacity: from 25 to 125 kW ❯❯Refrigerant: r407c ❯❯Sizes: 11 Main Functions: ❯❯2 scroll compressors/1 refrigerant circuit ❯❯Centrifugal Fans Product Advantages ❯❯Scroll compressors. ❯❯Brazed stainless steel plate heat exchangers. ❯❯Microprocessor based iltc control. ❯❯r407c refrigerant. ❯❯Anti-vibration pads: rubber anti-vibration pads, to ❯❯Compact units taking up the strict minimum of ground surface area, for easy ❯❯Anti-vibration mounts: Visible spring anti- Main accessories and options installation. ❯❯“Plug and Play” design with an integrated hydraulic module for minimising installation costs. ❯❯Accessibility: easy access to all components, thanks to panels removable by screws, thus significantly reducing unit maintenance times. WORKING LIMITS (to be confirmed following selection software issue) COOLING MODE Leaving water temperature without glycol Outdoor air temperature BLN 5/18°C 15/46°C -7/46°C (with optional fan speed control) 14 be fitted on site by the installer. vibration mounts, for on site fitting by the installer. compressor jacket: Supplied fitted. ❯❯Condenser coil protective coating: - aluminium fins with hydrophilic coating, - aluminium fins with polyurethane coating. ❯❯High static motor. ❯❯Remote control terminal: Hard-wired control enabling the unit’s Start/Stop functions to be controlled remotely. ❯❯Fow ambient kit (-7°c): Factory-fitted option consists of frequency inverter acting on the motor in order to keep fan speed under control. ❯❯Chiller sequencer: Supplied loose, it allows a control up to 4 units. ❯❯Water isolating valves: Supplied loose. ❯❯Water flow switch: Factory-installed option for models 25 to 35. ❯❯Double water pump: Supplied with a control and power supply remote panel. the electrical supply of the latter is to be carried out by others during installation. ❯❯Inlet air duct collar. aQcl siZes 25 30 35 40 50 60 70 80 100 120 130 kW 24,9 28,8 33,7 39,6 46,2 56,3 67,5 76,5 99,1 113,7 124,8 Power input (compressor) kW 11,5 12,9 14,2 16,1 22,0 25,5 28,5 32,0 40,95 44,25 47,95 Direct Direct Direct Direct Direct 1 1 1 1 1 COOLING CAPACITy (1) Power supply Startup type 400V/3+N/50Hz Direct Direct Direct Direct Direct Direct REFRIGERANT Type Number of refrigerant circuit R407C 1 1 1 1 1 1 COMPRESSORS Number 2 2 2 2 2 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll 1 1 1 1 1 1 1 1 1 1 1 Plaque Plaque Plaque Plaque Plaque Plaque Plaque Plaque Plaque Plaque Plaque Number 1 1 1 1 1 1 1 1 1 1 1 Number 2 2 2 2 2 2 2 2 2 2 2 Inlet/Outlet diameter pouces 1"1/2 1"1/2 1"1/2 2" 2" 2" 2" 2" 2" 2" 2" Operating with pump kg 387 405 415 575 630 660 865 920 1010 1080 1130 Operating without pump kg 377 395 405 565 620 650 855 910 988 1058 1108 Type EVAPORATOR Number Type COIL FANS WATER CONNECTIONS Type Pas du gaz WEIGHT DIMEnSIOnS Length mm 1752 1752 1752 2206 2206 2206 2464 2464 2464 2464 2464 Width mm 890 890 890 890 890 890 1100 1100 1100 1100 1100 Height mm 1505 1505 1505 1773 1773 1773 2313 2313 2313 2313 2313 81 81 80,8 86,1 86,1 83,3 83,3 87,8 87,8 87,8 ACOUSTICAL DATA (NORMAL MODE) Sound power level dB(A) 81 (1) Values are based on chilled water inlet/outlet temperature of 12/7°C and an outdoor temperature of 35°C. 15 Air Cooled Chiller | EQPLU 128.1 / 204.2 cooling only Scroll R410A ❯❯Cooling Capacity from 128 to 200 KW ❯❯Size = 10 ❯❯Refrigerant : R410A ❯❯EER up to 2.98 ❯❯ESSEER up to 3.99 Main Functions: ❯❯Available with one or 2 cooling circuit ❯❯Tandem scroll per refrigerant circuit ❯❯Microchannel full aluminium condenseur Available Versions: ❯❯Partial heat recovery ❯❯Total heat recovery ❯❯Extra low noise ❯❯EC fan version ❯❯Brine ❯❯Low ambiant operation up to -12°C STD Main accessories and options Code 79 83 101 118 119 150 170 171 250 350 Product Advantages ❯❯Tandem scroll compressors per circuit for a highest efficiency ❯❯Choice mono or bi-circuit ❯❯High ESEER ❯❯Reduce refrigerant charge thanks to the microchannel technology ❯❯Choice of the sound level ❯❯Total or partial heat recovery ❯❯EC fan motor for available static pressure ❯❯remote demand limit via additional elec board ❯❯Analog set point compensation ❯❯Eurovent certified ❯❯Easy maintenance 449 450 451 454 WORKING LIMITS - cooling Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. Evaporator outlet temperature (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit -5 -10 -13 -10 -5 0 5 10 15 20 25 30 35 40 45 (°C) Ambiant air temperature 16 720 721 722 723 725 726 727 728 923 926 931 932 934 943 Electrical panel heating system Compressor operation indicator EC Fan Brine version kit A Brine version kit B LNO Kit Spring antivibration holders Rubber antivibration holders Coils protection nets Kit TK PRO KIT protective coating for hard environnement Voltage free contact for partial heat recovery water pump activation Desuperheater 100% Heat Reclaim Voltage free contact for 100% heat recovery water pump activation Average discharge head single pump Average discharge head double pump Low discharge head single pump Low discharge head double pump Water tank + 1 pump medium pressure Water tank + 2 pump medium pressure Water tank + 1 pump low pressure Water tank + 2 pump low pressure COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Data Logger 17 125 40,8 70,8 21,5 46 113 160 46,7 78,4 27,7 9 ---scroll 2 97 321 2 1 PHE 8,8 40,7 1 8,8 30 ---2 42360 3,2 7,8 0 2 42360 2,6 7,8 0 R410A 12,3 2 400/3/50+N 2,84 3,26 62,1 80,3 HYG 360/1 HYG 360/2 360 2960 1200 1950 910 73,1 73,1 123 40,6 70,7 21,2 49 113 159 46,7 78,3 27,7 9 45,3 7,8 25 scroll 2 97 321 2 1 PHE 8 40,6 1 8 29,9 1 1,7 11 2 42360 3,2 7,8 0 2 42360 2,6 7,8 0 R410A 12,3 1 400/3/50+N 2,81 3,77 62,1 80,3 HYG 360/1 HYG 360/2 360 2960 1200 1950 910 73,1 1+1/2" 73,1 kW kW A m³/h kPa kW kW kW A m³/h kPa kW m³/h kPa kW/kW dB(A) dB(A) l mm mm mm kg Ø Ø mm Ø Ø mm kg n. V/Ph/Hz l m³/h n. l m³/h n. l m³/h n. m³/h kW A Pa n. m³/h kW A Pa n. A A n. n. 128.2 128.1 73,1 1+1/2" 73,1 930 2960 1200 1950 HYG 360/1 HYG 360/2 360 62,1 80,3 2,7 3,61 50,6 8,7 31,3 scroll 2 113,9 359 2 1 PHE 9 45,4 1 9 33,5 1 1,7 12,3 2 42360 3,2 7,8 0 2 42360 2,6 7,8 0 R410A 12,3 1 400/3/50+N 128 182 53,9 90,4 31,6 12 138 48 82,4 23,7 50 146.1 73,1 - 73,1 2960 1200 1950 930 HYG 360/1 HYG 360/2 360 62,1 80,3 2,7 3,11 ---scroll 2 113,9 359 2 1 PHE 8,8 45,5 1 8,8 33,5 ---2 42360 3,2 7,8 0 2 42360 2,6 7,8 0 R410A 12,5 2 400/3/50+N 128 182 53,9 90,4 31,6 13 138 48 82,4 23,8 56 146.2 73,1 1+1/2" 73,1 990 4000 1200 1970 GPUM2/1 GPUB2/1 GPUM2/2 GPUB2/2 200 62,5 81,3 2,98 3,99 59,8 10,3 31 scroll 2 131 321 2 1 PHE 11 53,7 1 11 39,7 1 2,3 14,6 3 63540 4,7 11,7 0 3 63540 3,8 11,7 0 R410A 12 1 400/3/50+N 143 204 61,1 103 35,5 13 163 50 86,8 28 51 164.1 73,1 1+1/2" 73,1 1030 4000 1200 1970 GPUM2/1 GPUB2/1 GPUM2/2 GPUB2/2 200 64,1 82,8 2,84 3,81 66,5 11,5 32,2 scroll 2 148 473 2 1 PHE 12 59,8 1 12 44,1 1 2,8 16,2 3 63540 4,7 11,7 0 3 63540 3,8 11,7 0 R410A 20,9 1 400/3/50+N 162 232 69,4 116 40,3 15 181 59,1 101 31,2 52 186.1 73,1 - 73,1 1040 4000 1200 1970 GPUM2/1 GPUB2/1 GPUM2/2 GPUB2/2 200 64,1 82,8 2,85 3,29 ---scroll 2 148 473 2 1 PHE 9,8 59,9 1 9,8 44,2 ---3 63540 4,7 11,7 0 3 63540 3,8 11,7 0 R410A 23,5 2 400/3/50+N 163 232 69,3 116 40,3 15 182 59,1 101 31,2 51 186.2 73,1 1+1/2" 73,1 4000 1200 1970 1060 GPUM2/1 GPUB2/1 GPUM2/2 GPUB2/2 200 65,2 84 2,72 3,64 73,1 12,6 35,6 scroll 2 165,2 491 2 1 PHE 14 65,7 1 14 48,5 1 3,1 17,8 3 63540 4,7 11,7 0 3 63540 3,8 11,7 0 R410A 21,4 1 400/3/50+N 181 259 78 130 45 16 199 68,5 116 34,3 50 204.1 5. Sound power level [Lw] according to ISO EN 9614 – 2 6.PHE = welded plate evaporator; S&T = shell and tube evaporator. 73,1 - 73,1 1020 4000 1200 1970 GPUM2/1 GPUB2/1 GPUM2/2 GPUB2/2 200 62,5 81,3 2,98 3,45 ---scroll 2 131 321 2 1 PHE 8,6 53,8 1 8,6 39,7 ---3 63540 4,7 11,7 0 3 63540 3,8 11,7 0 R410A 13,7 2 400/3/50+N 144 205 61 102 35,6 14 163 50 86,8 28 55 164.2 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature 2 .Gross value - Referred to chiller water temperature 12/7°C and hot water temperature and hot water temperature 40/45°C. 40/45°C. 4. Sound pressure level [LPm] 1m far according to ISO EN 3744 COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) HEATING CAPACITY Heat recovery water flow rate Heat recovery pressure drop COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR Type (6) Water volume Max water flow rate TOTAL HEAT RECOVERY EXCHANGER Water volume Max water flow rate PARTIAL HEAT RECOVERY EXCHANGER Water volume Max water flow rate AXIAL FANS AC Total air flow Power input Plate current [FLA] Max external static pressure AXIAL FANS EC (OPTIONAL) Total air flow Power input Plate current [FLA] Max external static pressure REFRIGERANT Total refrigerant charge (optional excluded) Gas circuits POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) EER - Energy Efficiency Ratio ESEER = Eurovent Standard SOUND LEVEL Average sound pressure level [LPm] (4) Sound power level [Lw] (5) HYDRONIC GROUP Average discharge head single pump Low discharge head single pump Average discharge head twin pump Low discharge head twin pump Water tank volume DIMENSIONS Length Width Height NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet - OD PARTIAL HEAT RECOVERY Inlet / Outlet – ISO 7/1 – R Inlet / Outlet – ISO 228/1-GM TOTAL HEAT RECOVERY Inlet / Outlet - OD COOLING ONLY (1) EQPLU SIZE 73,1 - 73,1 4000 1200 1970 1070 GPUM2/1 GPUB2/1 GPUM2/2 GPUB2/2 200 65,2 84 2,73 3,14 ---scroll 2 165,2 491 2 1 PHE 11,7 65,8 1 11,7 48,5 ---3 63540 4,7 11,7 0 3 63540 3,8 11,7 0 R410A 24,3 2 400/3/50+N 182 259 77,9 130 45,1 15 200 68,5 116 34,3 48 204.2 Air Cooled Chiller | EQPL 215 / 830 cooling only Scroll R410A ooling Capacity from 210 to 808 KW C Size = 20 Refrigerant : R410A EER up to 3,11 ESSEER up to 4,18 Main Functions: available with 2, 3, or 4 cooling circuits Tandem scroll per refrigerant circuit Microchannel full aluminium condenseur Modern design and modular Shell and tube evaporator from the size 430 Main accessories and options Available Versions: artial heat recovery P Total heat recovery Extra low noise EC fan version Brine Low ambiant operation up to -12°C STD Product Advantages arge cooling capacity range with scroll technology with a maximum reliability L thanks to the multi circuit Tandem scroll compressors per circuit for a highest efficiency and reliability Electronic Expansion valve STD High ESEER Screen display with graphics symbols for an easy reading Reduce refrigerant charge thanks to the microchannel technology Choice of the sound level Total or partial heat recovery EC fan motor for available static pressure Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. (°C) Evaporator outlet temperature 20 15 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -13 -10 -5 0 5 10 15 20 449 450 451 454 459 720 721 722 723 725 726 727 728 923 926 931 934 943 10 -10 Code 79 83 101 118 119 150 170 171 180 183 251 350 25 30 35 40 45 (°C) Ambiant air temperature 18 Electrical panel heating system Compressor operation indicator EC Fan Brine version kit A Brine version kit B LNO Kit Spring antivibration holders Rubber antivibration holders Power factor capacitor for motor compressor Complete hydraulic connection Coils protection nets Kit TK PRO KIT protective coating for hard environnement Voltage free contact for partial heat recovery water pump activation Desuperheater 100% Heat Reclaim Voltage free contact for 100% heat recovery water pump activation Shell and tube evaporator Average discharge head single pump Average discharge head double pump Low discharge head single pump Low discharge head double pump Water tank + 1 pump medium pressure Water tank + 2 pump medium pressure Water tank + 1 pump low pressure Water tank + 2 pump low pressure COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board MP.COM expansion card Data Logger EQPL SIZE 215.2 235.2 255.2 285.2 305.2 kW kW A m³/h kPa 210 62,8 115 36 54 229 71,1 125 39,3 54 250 81,5 142 43 54 282 96,6 166 48,4 53 302 87,5 153 51,9 52 kW kW kW A m³/h kPa 203 269 66,4 120 46,8 89 224 298 73,7 128 51,7 97 251 332 80,9 141 57,7 73 290 383 92,3 160 66,5 78 294 385 91,9 159 67 71 HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 77 13,3 18,1 84 14,5 21,5 91,8 15,8 25,7 103 17,8 26,5 111 19,1 26,7 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Type (6) Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS AC Total air flow Power input Plate current [FLA] Max external static pressure AXIAL FANS EC (OPTIONAL) Total air flow Power input Plate current [FLA] Max external static pressure scroll scroll scroll scroll 4 177 401 4 4 194 418 4 4 228 472 4 4 228 472 4 1 1 1 1 1 PHE 11,7 68,2 PHE 13,3 74,4 PHE 15,1 81,5 PHE 18,6 91,9 PHE 22,8 98,4 1 1 1 1 1 11,7 65,5 13,3 72,4 15,1 80,8 18,6 93,1 22,8 93,8 2 2 2 2 2 3,5 18,5 3,5 20,2 3,5 22,1 4,1 24,9 4,6 26,7 n. 4 4 4 4 6 m³/h kW A Pa 84720 6,3 15,6 0 84720 6,3 15,6 0 84720 6,3 15,6 0 84720 6,3 15,6 0 127080 9,5 23,4 0 n. 4 4 4 4 6 m³/h kW A Pa 84720 5,1 15,6 80 84720 5,1 15,6 80 84720 5,1 15,6 80 84720 5,1 15,6 80 127080 7,7 23,4 80 REFRIGERANT R410A R410A R410A R410A R410A 19,3 2 19,6 2 19,9 2 19,9 2 27,6 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,04 4,07 2,96 3,96 2,85 3,82 2,74 3,67 3,11 4,18 68,9 87,7 70 88,8 71,2 90 71,2 90 71,2 90,6 GPVM1/1 GPVB1/1 GPVM1/2 GPVB1/2 130 GPVM1/1 GPVB1/1 GPVM1/2 GPVB1/2 130 GPVM1/1 GPVB1/1 GPVM1/2 GPVB1/2 130 GPVM1/1 GPVB1/1 GPVM1/2 GPVB1/2 130 GPVM1/1 GPVB1/1 GPVM1/2 GPVB1/2 190 Length mm Width mm Height mm 2410 2260 2304 2410 2260 2304 2410 2260 2304 2410 2260 2304 3530 2260 2304 kg 1730 1920 1970 2010 2280 88,9 88,9 88,9 88,9 88,9 -2 x 1” -2 x 1” -2 x 1” -2 x 1” -2 x 1” 88,9 88,9 88,9 88,9 88,9 Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) scroll 4 165 389 4 V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER = Eurovent Standard SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) HYDRONIC GROUP Average discharge head single pump Low discharge head single pump Average discharge head twin pump Low discharge head twin pump Water tank volume l DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet – ISO 7/1 – R Ø Inlet / Outlet – ISO 228/1-GM Ø TOTAL HEAT RECOVERY Inlet / Outlet - OD Ø mm 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 19 4. Sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 – 2 6. PHE = welded plate evaporator; S&T = shell and tube evaporator. ➜ Cooling only - EQPL 215 / 830 | EQPL SIZE 340.2 380.2 410.2 430.3 470.3 kW kW A m³/h kPa 333 101 174 57,2 53 370 119 203 63,6 51 405 138 233 69,5 52 423 145 248 72,7 31 456 141 245 78,4 36 kW kW kW A m³/h kPa 329 431 103 178 75 73 371 489 118 202 85 77 413 547 134 227 95 88 ------- ------- HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 122 21,1 32,4 136 23,4 33,5 148 25,6 36,7 155 26,7 26,5 167 28,8 27 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Type (6) Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS AC Total air flow Power input Plate current [FLA] Max external static pressure AXIAL FANS EC (OPTIONAL) Total air flow Power input Plate current [FLA] Max external static pressure scroll scroll scroll scroll 4 296 621 4 4 330 656 4 6 342 586 6 6 359 603 6 1 1 1 1 1 PHE 22,8 108,7 PHE 26 120,8 PHE 29,2 132,3 S&T 133,4 138 S&T 133,4 148,4 1 1 1 -- -- 22,8 105 26 119 29,2 133 --- --- 2 2 2 3 3 4,6 29,4 5,6 32,7 6,4 35,8 6,2 37,4 7 40,3 n. 6 6 6 6 8 m³/h kW A Pa 127080 9,5 23,4 0 127080 9,5 23,4 0 127080 9,5 23,4 0 127080 9,5 23,4 0 169440 12,6 31,2 0 n. 6 6 6 6 8 m³/h kW A Pa 127080 7,7 23,4 80 127080 7,7 23,4 80 127080 7,7 23,4 80 127080 7,7 23,4 80 169440 10,2 31,2 80 REFRIGERANT R410A R410A R410A R410A R410A 28,1 2 28,3 2 28,3 2 29,9 3 38,6 3 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,01 4,06 2,88 3,87 2,75 3,69 2,74 3,67 2,97 3,98 71,2 90,7 73,6 93 75,1 94,6 72,9 92,4 72,9 93 GPVM1/1 GPVB1/1 GPVM1/2 GPVB1/2 190 GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 190 GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 190 GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - Length mm Width mm Height mm 3530 2260 2304 3530 2260 2304 3530 2260 2304 3530 2260 2304 4650 2260 2304 kg 2310 2360 2410 2980 3270 88,9 88,9 88,9 168,3 168,3 -2 x 1” -2 x 1” -2 x 1” -3 x 1” -3 x 1” 88,9 88,9 88,9 -- -- Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) scroll 4 262 506 4 V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER = Eurovent Standard SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) HYDRONIC GROUP Average discharge head single pump Low discharge head single pump Average discharge head twin pump Low discharge head twin pump Water tank volume l DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet – ISO 7/1 – R Ø Inlet / Outlet – ISO 228/1-GM Ø TOTAL HEAT RECOVERY Inlet / Outlet - OD Ø mm 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 20 4. Sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 – 2 6. PHE = welded plate evaporator; S&T = shell and tube evaporator. 500.3 540.3 560.3 610.3 630.3 680.4 720.4 750.4 800.4 830.4 497 160 274 85,4 43 526 178 303 90,5 48 547 177 303 94,1 51 602 207 350 104 58 615 202 342 106 60 666 201 349 114 67 701 220 378 120 74 729 238 406 125 81 775 256 435 133 87 808 276 467 139 55 ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- 182 31,4 32 193 33,3 30,2 201 34,6 32,6 221 38,1 36,2 226 38,9 37,7 244 42,1 32,4 257 44,3 30,1 267 46,1 32,5 284 49 33,7 296 51 36,6 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 6 393 718 6 6 427 753 6 6 444 769 6 6 496 821 6 6 496 821 6 8 523 866 8 8 558 883 8 8 592 917 8 8 626 952 8 8 661 986 8 1 1 1 1 1 1 1 1 1 1 S&T 124,7 161 S&T 124,7 170,2 S&T 124,7 177,1 S&T 221,7 195,5 S&T 221,7 200,1 S&T 221,7 215,1 S&T 206,5 226,6 S&T 206,5 235,8 S&T 206,5 250,7 S&T 184,4 262,2 -- -- -- -- -- -- -- -- -- -- --- --- --- --- --- --- --- --- --- --- 3 3 3 3 3 4 4 4 4 4 7 43,4 8,4 46,3 9,6 48,4 9,6 53,1 9,6 54,3 9,3 58,5 11,2 61,6 11,2 64,6 12,7 68,8 12,7 71,4 8 8 9 9 10 12 12 12 12 12 169440 12,6 31,2 0 169440 12,6 31,2 0 190620 14,2 35,1 0 190620 14,2 35,1 0 211800 15,8 39 0 254160 19 46,8 0 254160 19 46,8 0 254160 19 46,8 0 254160 19 46,8 0 254160 19 46,8 0 8 8 9 9 10 12 12 12 12 12 169440 10,2 31,2 80 169440 10,2 31,2 80 190620 11,5 35,1 80 190620 11,5 35,1 80 211800 12,8 39 80 254160 15,4 46,8 80 254160 15,4 46,8 80 254160 15,4 46,8 80 254160 15,4 46,8 80 254160 15,4 46,8 80 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 38,6 3 38,6 3 42,4 3 42,6 3 46,4 3 56,3 4 56,6 4 56,6 4 56,6 4 56,7 4 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,88 3,83 2,76 3,69 2,86 3,83 2,72 3,66 2,82 3,8 3,03 4,11 2,93 4,01 2,84 3,9 2,82 3,86 2,74 3,75 74,3 94,3 75,9 95,9 75,3 95,8 76,9 97,4 76,9 97,4 74,2 95,1 75,5 96,5 76,6 97,5 77,4 98,3 78,1 99 GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - GPVM2/1 GPVB2/1 GPVM2/2 GPVB2/2 - GPVM3/1 GPVB3/1 GPVM3/2 GPVB3/2 - GPVM3/1 GPVB3/1 GPVM3/2 GPVB3/2 - GPVM3/1 GPVB3/1 GPVM3/2 GPVB3/2 - GPVM3/1 GPVB3/1 GPVM3/2 GPVB3/2 - 4650 2260 2304 4650 2260 2304 5770 2260 2304 5770 2260 2304 5770 2260 2304 6890 2260 2304 6890 2260 2304 6890 2260 2304 6890 2260 2304 6890 2260 2304 3330 3360 3700 3940 3940 4530 4600 4630 4670 4750 168,3 168,3 168,3 219,1 219,1 219,1 219,1 219,1 219,1 219,1 -3 x 1” -3 x 1” -3 x 1” -3 x 1” -3 x 1” -4 x 1” -4 x 1” -4 x 1” -4 x 1” -4 x 1” -- -- -- -- -- -- -- -- -- -- 21 Air Cooled Chiller | EQPLA 106 / 860 Energy Class classA More efficient A+ A B C D E cooling only Scroll Class A Less efficient F G R410A Cooling Capacity from 210 to 808 KW Size = 31 Refrigerant : R410A EER up to 3,25 ESSEER up to 4,35 classA Main Functions: available with 2, 3, or 4 cooling circuits Tandem scroll per refrigerant circuit Microchannel full aluminium condenseur Modern design and modular Shell and tube evaporator from the size 430 Main accessories and options Code 79 101 118 119 150 170 171 183 350 Available Versions: artial heat recovery P Total heat recovery Extra low noise EC fan version Brine Low ambiant operation up to -12°C STD Product Advantages 449 classA Large cooling capacity range with scroll technology with a maximum reliability thanks to the multi circuit Tandem scroll compressors per circuit for a highest efficiency and reliability Electronic Expansion valve STD High ESEER Screen display with graphics symbols for an easy reading Reduce refrigerant charge thanks to the microchannel technology Choice of the sound level Total or partial heat recovery EC fan motor for available static pressure Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. Evaporator outlet temperature (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -10 -13 -10 -5 0 5 10 15 20 25 30 35 40 45 (°C) Ambiant air temperature 22 450 451 454 720 721 722 723 725 726 727 728 923 926 931 934 943 Electrical panel heating system EC Fan Brine version kit A Brine version kit B LNO Kit Spring antivibration holders Rubber antivibration holders Complete hydraulic connection TK PRO KIT protective coating for hard environnement Voltage free contact for partial heat recovery water pump activation Desuperheater 100% Heat Reclaim Voltage free contact for 100% heat recovery water pump activation Average discharge head single pump Average discharge head double pump Low discharge head single pump Low discharge head double pump Water tank + 1 pump medium pressure Water tank + 2 pump medium pressure Water tank + 1 pump low pressure Water tank + 2 pump low pressure COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board MP.COM expansion card Data Logger EQPLA SIZE 106.1 128.2 132.1 140.2 153.2 kW kW A m³/h kPa 108 31,8 58,2 18,6 33 124 35,2 64 21,4 46 134 38,9 68,5 23 34 139 40,4 74,6 23,9 39 152 43,6 83,4 26,1 46 kW kW kW A m³/h kPa 105 138 33,1 59,9 24,1 38 119 157 37,9 68 27,3 58 129 170 41 71,1 29,6 36 136 178 41,9 76,7 30,9 55 147 193 46,2 87,1 33,5 64 HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 39,7 6,8 27,2 45,7 7,9 18,7 49,1 8,5 29,4 51,1 8,8 23,4 55,7 9,6 19 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Type (6) Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS AC Total air flow Power input Plate current [FLA] Max external static pressure AXIAL FANS EC (OPTIONAL) Total air flow Power input Plate current [FLA] Max external static pressure scroll scroll scroll scroll 4 100 193 4 2 97 321 2 4 124 233 4 4 130 270 4 1 1 1 1 1 PHE 11 35,1 PHE 8,6 40,5 PHE 11 43,5 PHE 9,8 45,3 PHE 9,8 49,5 1 1 1 1 1 11 33,7 8,6 38,2 11 41,4 9,8 43,3 9,8 46,9 1 2 1 2 2 1,4 9,5 1,7 11 1,7 11,8 1,7 12,3 2,2 13,4 n. 4 6 6 6 6 m³/h kW A Pa 38940 2,2 7,9 0 53340 3,2 7,9 0 53340 3,2 7,9 0 53340 3,2 7,9 0 59300 3,2 7,9 0 n. 4 6 6 6 6 m³/h kW A Pa 38940 1,6 6,4 0 53340 2,3 9,6 0 53340 2,3 9,6 0 53340 2,3 9,6 0 59300 2,3 9,6 0 REFRIGERANT R410A R410A R410A R410A R410A 12 1 12 2 12,4 1 12,1 2 23,3 2 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 3,18 4,2 3,23 4,34 3,18 4,22 3,19 4,27 3,25 4,35 57,3 75,5 55,5 73,7 59,4 77,5 55,9 74,1 56,1 74,7 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 Length mm Width mm Height mm 2455 1750 2110 2455 1750 2110 2455 1750 2110 2455 1750 2110 2455 1750 2410 kg 1250 1310 1390 1330 1300 73,1 73,1 73,1 73,1 73,1 1" -- 1" -- 1" -- 1" -- 1" -- 73,1 73,1 73,1 73,1 73,1 Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) scroll 2 83 306 2 V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER = Eurovent Standard SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) HYDRONIC GROUP Average discharge head single pump Low discharge head single pump Average discharge head twin pump Low discharge head twin pump Water tank volume l DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet – ISO 7/1 – R Ø Inlet / Outlet – ISO 228/1-GM n x Ø TOTAL HEAT RECOVERY Inlet / Outlet - OD Ø mm 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 23 4. Sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 – 2 6. PHE = welded plate evaporator; S&T = shell and tube evaporator. ➜ Cooling only - EQPLA 106 / 860 | EQPLA SIZE 164.2 168.1 168.2 184.2 190.2 kW kW A m³/h kPa 164 48,4 94,5 28,2 42 170 50,6 87,6 29,2 25 171 50,6 87,7 29,4 34 185 55,2 101 31,8 35 189 53,3 99,7 32,4 43 kW kW kW A m³/h kPa 161 211 50,2 97 36,6 64 166 218 52,4 90,2 38 20 164 218 54 92,4 37,9 52 186 241 54,8 101 41,9 65 181 238 57,1 105 41,4 69 HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 60,4 10,4 22,3 62,3 10,7 33,7 62,7 10,8 24,1 68 11,7 20 69,2 11,9 14,6 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Type (6) Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS AC Total air flow Power input Plate current [FLA] Max external static pressure AXIAL FANS EC (OPTIONAL) Total air flow Power input Plate current [FLA] Max external static pressure scroll scroll scroll scroll 2 131 375 2 2 131 375 2 4 148 259 4 4 148 333 4 1 1 1 1 1 PHE 11,7 53,5 PHE 14 55,2 PHE 11,7 55,5 PHE 13,3 60,3 PHE 13,3 61,3 1 1 1 1 1 11,7 51,2 14 53,2 11,7 53,1 13,3 58,7 13,3 58 2 1 2 2 2 2,2 14,5 2,3 15 2,2 15,1 2,7 16,4 3,5 16,7 n. 6 6 6 6 4 m³/h kW A Pa 59300 3,2 7,9 0 59300 3,2 7,9 0 59300 3,2 7,9 0 59300 3,2 7,9 0 84720 6,3 15,6 0 n. 6 6 6 6 4 m³/h kW A Pa 59300 2,3 9,6 0 59300 2,3 9,6 0 59300 2,3 9,6 0 59300 2,3 9,6 0 84720 5,1 15,6 80 REFRIGERANT R410A R410A R410A R410A R410A 24,1 2 21,3 1 24,3 2 25 2 19 2 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50 3,18 4,27 3,16 4,19 3,18 3,63 3,17 4,25 3,17 4,24 56,3 74,9 59,4 77,9 59,4 77,9 58,1 76,7 66,7 85,5 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPWM1/1 GPWB1/1 GPWM1/2 GPWB1/2 200 GPVM1/1 GPVB1/1 GPVM1/2 GPVM1/2 130 Length mm Width mm Height mm 2455 1750 2410 2455 1750 2410 2455 1750 2410 2455 1750 2410 2410 2260 2304 kg 1440 1540 1530 1390 1700 73,1 73,1 73,1 73,1 88,9 1" -- 1" -- 1" -- 1" -- -2 x 1" 73,1 73,1 73,1 73,1 88,9 Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) scroll 4 136 276 4 V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER = Eurovent Standard SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) HYDRONIC GROUP Average discharge head single pump Low discharge head single pump Average discharge head twin pump Low discharge head twin pump Water tank volume l DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet – ISO 7/1 – R Ø Inlet / Outlet – ISO 228/1-GM n x Ø TOTAL HEAT RECOVERY Inlet / Outlet - OD Ø mm 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 24 4. Sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 – 2 6. PHE = welded plate evaporator; S&T = shell and tube evaporator. 214.2 236.2 270.2 304.2 340.2 374.2 390.2 410.2 430.2 455.3 218 62,5 115 37,5 38 235 68,8 121 40,3 38 271 75,1 134 46,6 33 308 87,7 154 52,9 43 344 99,2 172 59 35 372 104 180 63,9 41 394 112 194 67,6 35 413 118 203 70,9 39 438 126 215 75,2 38 471 130 228 80,9 38 214 278 64,5 117 48,4 73 234 303 69,1 121 52,7 69 260 341 80,6 141 59,2 46 299 391 92,2 160 67,9 60 340 441 101 174 76,6 52 357 468 111 190 81,2 58 382 499 118 202 86,8 33 402 525 123 210 91,3 61 430 559 129 219 97,2 62 ------- 80 13,8 19,5 86,1 14,8 22,6 99,6 17,2 24,6 113 19,5 27,7 126 21,7 34,5 137 23,5 33,9 145 24,9 38 152 26,1 38,3 161 27,7 43 173 29,8 22,2 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 4 165 389 4 4 177 401 4 4 194 418 4 4 228 472 4 4 262 506 4 4 279 604 4 4 296 621 4 4 313 639 4 4 330 656 4 6 342 586 6 1 1 1 1 1 1 1 1 1 1 PHE 15,1 71 PHE 15,1 76,4 PHE 18,6 88,3 PHE 26 100,3 PHE 30 111,9 PHE 31,6 120,8 PHE 133,4 127,7 PHE 133,4 134,6 PHE 124,7 142,6 S&T 113,5 153 1 1 1 1 1 1 1 1 1 -- 15,1 67,8 15,1 73,8 18,6 82,9 26 95,1 30 107,2 31,6 113,7 133,4 121,5 133,4 127,8 124,7 136,1 --- 2 2 2 2 2 2 2 2 2 3 3,5 27 3,5 20,7 4,1 24 4,6 27,2 4,6 30,4 5,6 32,9 6,4 34,8 6,4 36,5 6,4 38,7 7 41,2 4 4 6 6 6 8 8 8 8 10 84720 6,3 15,6 0 84720 6,3 15,6 0 127080 9,5 23,4 0 127080 9,5 23,4 0 127080 9,5 23,4 0 169440 12,6 31,2 0 169440 12,6 31,2 0 169440 12,6 31,2 0 169440 12,6 31,2 0 211800 15,8 39 0 4 4 6 6 6 8 8 8 8 10 84720 5,1 15,6 80 84720 5,1 15,6 80 127080 7,7 23,4 80 127080 7,7 23,4 80 127080 7,7 23,4 80 169440 10,2 31,2 80 169440 10,2 31,2 80 169440 10,2 31,2 80 169440 10,2 31,2 80 211800 12,8 39 80 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 19,4 2 20,2 2 27,8 2 27,8 2 28,3 2 36,2 2 36,2 2 36,3 2 36,3 2 41,7 3 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,17 4,25 3,13 4,23 3,2 4,31 3,17 4,25 3,16 4,25 3,19 4,29 3,16 4,23 3,16 4,23 3,16 4,24 3,23 4,23 68,9 87,7 70 88,8 71,2 90,7 71,2 90,7 71,2 90,7 72,6 92,6 73,6 93,6 74,4 94,4 75,1 95,1 73 93,5 GPVM1/1 GPVB1/1 GPVM1/2 GPVM1/2 130 GPVM1/1 GPVB1/1 GPVM1/2 GPVM1/2 130 GPVM1/1 GPVB1/1 GPVM1/2 GPVM1/2 190 GPVM1/1 GPVB1/1 GPVM1/2 GPVM1/2 190 GPVM1/1 GPVB1/1 GPVM1/2 GPVM1/2 190 GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 330 GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 330 GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 330 GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 330 GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- 2410 2260 2304 2410 2260 2304 3530 2260 2304 3530 2260 2304 3530 2260 2304 4650 2260 2304 4650 2260 2304 4650 2260 2304 4650 2260 2304 5770 2260 2304 1740 1930 2250 2300 2340 2640 2690 2710 2730 3620 88,9 88,9 88,9 88,9 88,9 114,3 114,3 114,3 114,3 168,3 -2 x 1" -2 x 1" -2 x 1" -2 x 1" -2 x 1" -2 x 1" -2 x 1" -2 x 1" -2 x 1" -3 x 1" 88,9 88,9 88,9 88,9 88,9 114,3 114,3 114,3 114,3 -- ➜ 25 Cooling only - EQPLA 106 / 860 | EQPLA SIZE 504.3 530.3 550.3 584.3 604.3 kW kW A m³/h kPa 523 145 253 89,8 36 539 156 269 92,6 38 563 163 280 96,7 41 593 169 291 102 44 614 175 301 105 47 kW kW kW A m³/h kPa ------- ------- ------- ------- ------- 192 33 35,4 198 34,1 37,8 207 35,6 34,5 218 37,5 38,2 225 38,8 37,6 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Type (6) Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS AC Total air flow Power input Plate current [FLA] Max external static pressure AXIAL FANS EC (OPTIONAL) Total air flow Power input Plate current [FLA] Max external static pressure scroll scroll scroll scroll scroll 6 392 637 6 6 410 735 6 6 427 752 6 6 444 769 6 6 461 787 6 1 1 1 1 1 S&T 221,7 170,2 S&T 221,7 176 S&T 221,7 182,9 S&T 206,5 193,2 S&T 206,5 200,1 -- -- -- -- -- --- --- --- --- --- 3 3 3 3 3 7 45,7 9,6 47,7 9,6 49,8 9,6 52,4 9,6 54,3 n. 10 10 10 12 12 m³/h kW A Pa 211800 15,8 39 0 211800 15,8 39 0 211800 15,8 39 0 254160 19 46,8 0 254160 19 46,8 0 n. 10 10 10 12 12 m³/h kW A Pa 211800 12,8 39 80 211800 12,8 39 80 211800 12,8 39 80 254160 15,4 46,8 80 254160 15,4 46,8 80 REFRIGERANT R410A R410A R410A R410A R410A 42,4 3 46,6 3 46,6 3 54,4 3 54,4 3 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,25 4,22 3,14 4,22 3,15 4,23 3,15 4,23 3,16 4,23 73 93,5 73,9 94,4 74,7 95,2 75,3 96,3 75,9 96,9 GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- Length mm Width mm Height mm 5770 2260 2304 5770 2260 2304 5770 2260 2304 6890 2260 2304 6890 2260 2304 kg 3820 3840 3860 4180 4200 Inlet / Outlet - OD Ø mm 219,1 219,1 219,1 219,1 219,1 Inlet / Outlet – ISO 7/1 – R Ø Inlet / Outlet – ISO 228/1-GM n x Ø TOTAL HEAT RECOVERY Inlet / Outlet - OD Ø mm -3 x 1" -3 x 1" -3 x 1" -3 x 1" -3 x 1" -- -- -- -- -- Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER = Eurovent Standard SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) HYDRONIC GROUP Average discharge head single pump Low discharge head single pump Average discharge head twin pump Low discharge head twin pump Water tank volume l DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR PARTIAL HEAT RECOVERY 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 26 4. Sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 – 2 6. PHE = welded plate evaporator; S&T = shell and tube evaporator. 646.3 670.3 726.4 780.4 820.4 860.4 655 188 320 112 52 691 200 346 119 32 743 213 368 128 40 769 224 385 132 42 832 237 407 143 37 876 252 429 150 39 ------- ------- ------- ------- ------- ------- 240 41,4 42,8 253 43,7 47,6 273 47 40,3 282 48,6 36,2 305 52,6 42,3 321 55,4 43 scroll scroll scroll scroll scroll scroll 6 496 821 6 8 523 768 8 8 558 883 8 8 592 917 8 8 626 952 8 8 661 986 8 1 1 1 1 1 1 S&T 206,5 212,8 S&T 184,4 224,3 S&T 184,4 241,5 S&T 184,4 250,7 S&T 225 270,3 S&T 225 285,2 -- -- -- -- -- -- --- --- --- --- --- --- 3 3 4 4 4 4 9,6 57,9 9,3 61 11,2 65,7 12,7 68 12,7 73,5 12,7 77,4 12 12 14 14 16 16 254160 19 46,8 0 254160 19 46,8 0 296520 22,1 54,6 0 296520 22,1 54,6 0 338880 25,3 62,4 0 338880 25,3 62,4 0 12 12 14 14 16 16 254160 15,4 46,8 80 254160 15,4 46,8 80 296520 17,9 54,6 80 296520 17,9 54,6 80 338880 20,5 62,4 80 338880 20,5 62,4 80 R410A R410A R410A R410A R410A R410A 54,4 3 56,6 4 64,6 4 64,7 4 72,5 4 72,6 4 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,16 4,25 3,16 4,31 3,16 4,31 3,12 4,26 3,17 4,32 3,16 4,32 76,9 97,8 74,2 95,5 77,4 98,8 76,6 97,9 77,4 99,1 78,1 99,8 GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- GPVM2/1 GPVB2/1 GPVM2/2 GPVM2/2 -- GPVM3/1 GPVB3/1 GPVM3/2 GPVM3/2 -- GPVM3/1 GPVB3/1 GPVM3/2 GPVM3/2 -- GPVM3/1 GPVB3/1 GPVM3/2 GPVM3/2 -- GPVM3/1 GPVB3/1 GPVM3/2 GPVM3/2 -- 6890 2260 2304 6890 2260 2304 8010 2260 2304 8010 2260 2304 9130 2260 2304 9130 2260 2304 4240 4860 4900 4940 5300 5340 219,1 219,1 219,1 219,1 219,1 219,1 -3 x 1" -3 x 1" -4 x 1" -4 x 1" -4 x 1" -4 x 1" -- -- -- -- -- -- 27 Air Cooled Chiller | EQUL 21 / 260 cooling only Scroll R410A ooling Capacity from 20 to 260 KW C Size = 29 Refrigerant : R410A EER up to 3,26 ESSEER up to 4,67 Main Functions: vailable with one or 2 cooling circuit a 1 or 2 scroll compressors following sizes Condenser coil on only one face implementation for difficult place Available Versions: Main accessories and options artial heat recovery P Total heat recovery Extra low noise Brine Low ambiant operation up to -12°C STD For available air static pressure see PF version next page Product Advantages Iimplantation angles or against wall Choice mono or bi-circuit Easy acces to component Water tank under the unit for a better mass repartition and low footprint (option) High performances Choice of the sound level Total or partial heat recovery Standard EC fan motor Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance Service valves on gas discharge and liquid line WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. Température sortie eau évaporateur (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 -10 -13 -10 -5 0 5 10 15 20 25 30 35 40 45 (°C) Température air extérieur 28 Code 118 150 151 170 172 175 251 351 450 451 605 731 739 740 756 757 768 919 923 926 931 932 934 942 943 Brine version kit A LNO Kit Kit ELN Spring antivibration holders Rubber support (kit) Victaulic Connections Coils protection nets Kit Coils with pre painted fins Desuperheater 100% Heat Reclaim Compr. Power factor capcitor 0,9 Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group LN 1 pump Pumping group LN 2 pumps Chilled water storage tank Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQUL MODEL 21.1 24.1 28.1 30.1 34.1 40.1 50.1 kW kW A m³/h kPa 19,8 6,1 11,1 3,4 28 22,4 7,1 13,3 3,9 36 26,5 8,2 15,3 4,6 38 29,2 9,7 17,2 5 29 34 10,2 18,6 5,8 38 39 12,4 23,9 6,7 39 49,6 15,9 28 8,5 35 kW kW kW A m³/h kPa 21,1 27,1 6 11 4,7 44 24,6 31,4 6,9 12,9 5,5 57 28,9 36,8 7,9 14,9 6,4 55 30,9 39,9 9 16,2 6,9 45 39,5 51,6 12,2 18,6 9 75 40 52 12 23,3 9 56 50,5 66,3 15,8 27,7 11,5 47 HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 7,3 1,3 18,7 8,2 1,4 23,9 9,7 1,7 33,3 10,7 1,9 13,7 12,5 2,2 18,5 14,3 2,5 24,3 18,2 3,1 39,3 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR (plate heat exchanger) scroll scroll scroll scroll scroll scroll scroll n. A A n. 1 16 95 1 1 21 111 1 1 22 118 1 1 25 118 1 1 31 140 1 1 34 174 1 1 40 225 1 n. 1 1 1 1 1 1 1 1,9 5,1 1,9 5,8 2,1 6,8 2,8 7,1 2,9 8,2 3,3 9,5 4,2 12,1 1 1 1 1 1 1 1 1,9 6 1,9 7,7 1,9 9 2,5 9,7 2,5 10,9 2,5 12,7 3,1 16,1 1 1 1 1 1 1 1 0,4 1,4 0,4 1,4 0,4 1,4 0,6 1,4 0,6 1,4 0,6 1,4 0,6 1,4 1 1 1 1 2 2 2 8500 0,5 1,6 8500 0,5 1,6 11000 0,8 1,6 11000 0,8 1,6 13000 0,5 3,2 15000 0,8 3,2 20500 1,6 3,3 R410A R410A R410A R410A R410A R410A R410A 5,3 1 5,3 1 5,3 1 5,5 1 7,7 1 7,7 1 9 1 Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Total air flow m³/h Engaged power kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER Eurovent Standard IPLV - ARI Standard 550/590 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,03 4,67 5,18 2,95 4,74 5,25 2,96 4,57 5,07 2,8 4,21 4,67 3,18 4,85 5,38 2,96 4,46 4,94 2,83 4,02 4,46 64,6 81,1 64,9 81,5 65,6 82,2 64,8 81,4 64,9 82,2 67,7 84,9 71,8 89 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 1250 890 2010 1250 890 2010 1250 890 2010 1250 890 2010 1800 1040 2060 1800 1040 2060 1800 1040 2060 350 350 360 360 520 520 610 Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD Ø mm 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 2" -- 2" -- 2" -- Inlet / Outlet (ISO 7/1 - R) Ø 1" 1" 1" 1" 1 1/4" 1 1/4" 1 1/4" Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD Ø mm 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 2" -- 2" -- 2" -- SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF UNI PPF UNI PPF UNI PPF UNI l DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg EVAPORATOR PARTIAL HEAT RECOVERY TOTAL HEAT RECOVERY 1.Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 29 ➜ 4.Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5- Sound power level [Lw] according to ISO EN 9614 – 2 Cooling only - EQUL 21 / 260 | EQUL MODEL 52.1 52.2 58.1 58.2 62.1 65.1 65.2 76.1 kW kW A m³/h kPa 50,5 16,7 31,1 8,7 36 50,5 16,4 30,5 8,7 21 57,7 18,6 33,5 9,9 36 60,8 17,5 31,4 10,5 19 61,2 20 34,6 10,5 30 64,8 20,9 38,3 11,1 35 64,7 21 38,2 11,1 21 75,4 24,9 48 13 37 kW kW kW A m³/h kPa 51,6 68,1 16,4 30,6 11,8 50 52,5 68,5 16,1 30,1 11,9 33 58,4 77 18,6 33,3 13,4 48 59,8 77,9 18,1 32,6 13,5 29 62,6 82,4 19,8 34,4 14,3 40 75,7 101 24,8 37,7 17,5 70 76,7 101 24,4 37,3 17,6 43 77,5 102 24,4 47,1 17,7 54 HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 18,5 3,2 26,6 18,5 3,2 30,3 21,2 3,7 34,6 22,3 3,8 14,8 22,4 3,9 38,9 23,8 4,1 43,7 23,7 4,1 16,7 27,7 4,8 34,6 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS scroll scroll scroll scroll scroll scroll scroll scroll Quantity Maximum current Starting current Capacity steps EVAPORATOR (plate heat exchanger) n. A A n. n. Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Total air flow m³/h Engaged power kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER Eurovent Standard IPLV - ARI Standard 550/590 2 44 140 2 2 44 140 2 2 50 143 2 2 50 143 2 1 48,5 272 1 2 62 171 2 2 62 171 2 2 68 208 2 1 1 1 1 1 1 1 1 4,2 12,3 4,3 12,3 4,8 14 5,3 14,1 5,7 14,9 5,5 15,8 5,6 15,8 6,3 18,4 1 1 1 1 1 1 1 1 3,9 16,7 3,6 18,8 3,9 19 3,6 20,1 3,9 16,6 4,7 21,3 4,2 21,4 5,8 24,8 1 2 1 2 1 1 2 1 0,8 1,4 2 x 0,4 2,8 0,8 2,8 2 x 0,6 2,8 0,8 2,8 0,8 2,8 2 x 0,6 2,8 1 2,8 2 2 3 3 3 3 3 3 20500 1,6 3,3 20500 1,6 3,3 22000 1,1 4,7 22000 1,1 4,7 23000 1,3 4,7 24000 1,5 4,7 24000 1,5 4,7 30000 2,4 4,9 R410A R410A R410A R410A R410A R410A R410A R410A 12,9 1 9,3 2 9 1 12,7 2 12,4 1 13,1 1 12,7 2 13,6 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,76 4,21 4,67 2,8 3,82 4,24 2,92 4,76 5,28 3,26 4,21 4,67 2,87 4,28 4,74 2,9 4,51 5,01 2,88 4,01 4,45 2,76 4,13 4,58 68,9 86,1 68,9 86,1 68 85,9 68 85,9 73,8 91,6 67,8 85,7 67,8 85,7 68,2 86,1 2/1 -2/1 LN -210 2/1 -2/1 LN -210 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 1800 1040 2060 1800 1040 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 590 590 810 810 850 820 820 840 Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD Ø mm 2" -- 2" -- -73 -73 -73 -73 -73 -73 Inlet / Outlet (ISO 7/1 - R) Ø 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD Ø mm 2" -- 2" -- -73 -73 -73 -73 -73 -73 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF UNI PPF UNI PPF UNI PPF UNI l DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg EVAPORATOR PARTIAL HEAT RECOVERY TOTAL HEAT RECOVERY 1.Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 30 4.Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5- Sound power level [Lw] according to ISO EN 9614 – 2 76.2 98.1 98.2 124.1 124.2 158.1 158.2 180.1 180.2 197.1 197.2 230.1 240.2 260.2 75 24,9 47,9 12,9 23 97,3 31,5 55,5 16,7 36 96,1 31,4 55,3 16,5 27 123 40 69,5 21,1 38 120 39,8 69,3 20,5 31 155 53 90,8 26,6 32 157 53,2 90,9 27 28 177 59,2 102 30,3 34 178 59,2 102 30,6 36 194 66,8 115 33,4 41 197 67,1 115 33,9 35 227 80,8 138 39 41 234 85,3 146 40,3 40 260 102 172 44,7 36 77,8 102 24,1 46,7 17,7 35 98,5 130 31,5 55,3 22,6 45 98,1 129 31,1 54,8 22,5 38 125 165 39,8 69,1 28,6 46 122 162 39,4 68,5 28,1 44 163 213 50 86,3 37,1 52 167 217 49,6 85,7 37,7 47 185 241 24,2 98,1 41,9 54 186 243 24,2 97,8 42,2 59 204 268 63,6 110 46,5 67 210 273 62,9 109 47,4 57 241 316 75,5 130 54,9 67 252 331 78,3 136 57,4 67 290 379 89 154 65,9 63 27,5 4,7 22,5 35,7 6,2 33,7 35,3 6,1 36,9 45 7,8 37,3 43,9 7,6 37,1 56,9 9,8 45,7 57,7 9,9 37,2 64,8 11,2 34,9 65,3 11,2 28,1 71,2 12,3 42,1 72,3 12,5 34,5 83,2 14,3 40,9 85,9 14,8 33,7 95,3 16,4 41,4 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 2 68 208 2 2 80 265 2 2 80 265 2 2 97 320,5 2 2 97 320,5 2 2 130,8 375,4 2 2 130,8 375,4 2 2 147,4 439,4 2 2 147,4 439,4 2 2 164 456 2 2 164 456 2 3 196,2 440,8 3 4 194 417,5 4 4 294,8 586,8 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5,9 18,3 8,4 23,7 7,5 23,5 10,5 29,9 8,8 29,2 10,5 37,9 11 38,4 13 43,1 17,2 43,4 16 47,4 19,6 48,1 18,8 55,3 22 57,1 23,6 63,3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5,1 24,8 5,8 31,7 6,7 31,4 7,2 40,1 6,7 39,3 8,7 52 8,3 52,8 11,1 58,7 9,5 59,1 17,6 64,9 15,8 66,1 17,6 76,9 20,3 80,4 20,3 92,3 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 x 0,6 2,8 1,7 2,8 2 x 0,6 2,8 2,1 2,8 2 x 0,8 2,8 4 2,8 2 x 1,0 2,8 5,3 2,8 2 x 2,1 2,8 5,3 2,8 2 x 2,1 2,8 6,3 4,2 2 x 2,1 5,6 2 x 2,1 5,6 3 4 4 4 4 4 4 5 5 5 5 5 5 5 30000 2,4 4,9 40000 2,5 6,5 40000 2,5 6,5 46000 3,6 11,4 46000 3,6 11,4 55800 6,4 11,4 55800 6,4 11,4 60000 4,6 14,3 60000 4,6 14,3 66000 6,1 14,3 66000 6,1 14,3 69000 7 14,3 69000 8,1 14,3 69000 8,1 14,3 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 13,5 2 18,9 1 19,3 2 23,5 1 24,1 2 24,6 1 24,9 2 47,4 1 47,8 2 49,3 1 49,6 2 49,9 1 60,8 2 60,6 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,75 3,71 4,11 2,86 4,39 4,87 2,84 3,92 4,35 2,82 4,21 4,67 2,77 3,74 4,15 2,61 3,75 4,16 2,63 3,46 3,84 2,78 4,26 4,72 2,79 3,81 4,23 2,66 4,02 4,46 2,69 3,64 4,04 2,59 4,27 4,73 2,51 3,45 3,83 2,36 3,37 3,74 68,2 86,1 65,6 84,2 65,6 84,2 69,5 88,1 69,5 88,1 72 90,6 72 90,6 69,3 88,6 69,3 88,6 71,1 90,4 71,1 90,4 71,9 91,2 73,6 92,9 73,8 93 3/1 3/2 3/1 LN 3/2 LN 360 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 2600 1200 2060 3700 1260 2050 3700 1260 2050 3700 1260 2050 3700 1260 2050 3700 1260 2050 3700 1260 2050 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 840 1310 1310 1380 1380 1410 1410 1860 1860 1870 1870 2020 2130 2170 -73 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 1 1/2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" -73 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 31 Air Cooled Chiller | EQUL PF 21 / 290 cooling only Scroll DUCTABLE R410A ooling Capacity from 20 to 260 KW C Size = 29 Refrigerant : R410A EER up to 3,26 ESSEER up to 4,67 Main Functions: vailable with one or 2 cooling circuit A 1 or 2 scroll compressors following sizes Condenser coil on only one face Implementation for difficult place Available static pressure from 50 to 700 Pa following models Plug fan as STD Main accessories and options Available Versions: artial heat recovery P Total heat recovery Extra low noise Brine Low ambiant operation up to -12°C STD Product Advantages uctable unit D Horizontal or vertical Blow Indoor implantation Choice mono or bi-circuit Easy acces to component High performances Choice of the sound level Water tank under the unit for a better mass repartition and low footprint (option) Total or partial heat recovery Standard EC fan motor Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance Service valves on gas discharge and liquid line WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. (°C) Evaporator outlet temperature 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 -10 -13 -10 -5 0 5 10 15 20 25 30 35 40 45 (°C) Ambiant air temperature 32 Code 118 119 150 151 160 170 172 175 251 351 450 451 460 605 731 739 740 756 757 768 822 919 923 926 931 932 934 942 943 Brine version kit A Brine version kit B LNO Kit Kit ELN Discharge air plenum with sound attenuator Spring antivibration holders Rubber support (kit) Victaulic Connections Coils protection nets Kit Coils with pre painted fins Desuperheater 100% Heat Reclaim Kit for Outdoor installation Compr. Power factor capcitor 0,9 Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group LN 1 pump Pumping group LN 2 pumps Chilled water storage tank Supply air plenum mounting kit Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQUL PF MODEL 22.1 24.1 28.1 32.1 36.1 42.1 53.1 kW kW A m³/h kPa 19,6 6,5 11,6 3,4 27 22,3 7,5 13,8 3,8 35 26 8,8 16,1 4,5 37 29,4 10 17,6 5,1 29 32,5 11,1 20,1 5,6 36 37,3 13,5 25,4 6,4 36 48,1 16,8 29,1 8,3 33 kW kW kW A m³/h kPa 20,6 26,6 6 11 4,6 45 23,6 30,5 6,9 12,9 5,3 60 27,9 35,8 7,9 14,9 6,2 57 31,6 40,6 9 16,2 7,1 47 35,4 45,6 10,2 18,7 7,9 59 41,5 53,3 11,9 22,8 9,3 59 50,5 66,3 15,8 27,7 11,5 47 HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 7,2 1,2 18,2 8,2 1,4 23,5 9,5 1,6 32,1 10,8 1,9 13,8 11,9 2,1 16,9 13,7 2,4 22,3 17,6 3 36,9 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR scroll scroll scroll scroll scroll scroll scroll n. A A n. 1 16 95 1 1 21 111 1 1 22 118 1 1 25 118 1 1 31 140 1 1 34 174 1 1 40 225 1 n. 1 1 1 1 1 1 1 1,9 5,2 1,9 5,9 1,9 6,8 2,5 7,8 2,5 8,8 2,5 10,1 3,1 12,8 1 1 1 1 1 1 1 1,9 6,4 1,9 7,4 1,9 8,6 2,5 9,8 2,5 11,1 2,5 13 3,1 16,1 1 1 1 1 1 1 1 0,4 1,9 0,4 2,2 0,4 2,5 0,6 2,9 0,6 3,2 0,6 3,7 0,6 4,7 n. 1 1 1 1 1 1 2 m³/h Pa Pa kW A 6500 50 737 0,6 4,3 7000 50 704 0,7 4,3 8500 50 509 1,1 4,3 10000 50 480 1,2 4,9 11000 50 312 1,6 4,9 12000 50 112 2,1 4,9 16000 50 568 2 8,6 R410A R410A R410A R410A R410A R410A R410A 5,3 1 5,3 1 5,3 1 5,5 1 5,6 1 5,6 1 9 1 Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h CENTRIGUGAL FANS Total air flow External static pressure Max external static pressure Power input Plate current [FLA] REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER = Standard Eurovent IPLV - ARI Standard 550/590 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,79 4,49 4,98 2,73 4,4 4,88 2,63 4,05 4,5 2,63 4,1 4,55 2,56 3,88 4,3 2,4 3,57 3,96 2,56 3,93 4,36 70,6 87,1 72,1 88,7 76,3 92,9 75,6 92,1 77,6 94,2 79,4 96 77,6 94,8 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 2/1 -2/1 LN -210 1250 890 1950 1250 890 1950 1250 890 1950 1250 890 1950 1250 890 1950 1250 890 1950 1800 1040 2000 370 370 380 390 390 400 630 Inlet / Outlet (ISO 7/1 – R) Ø Inlet / Outlet – OD (6) Ø mm 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 2" -- Inlet / Outlet (ISO 7/1 – R) Ø 1" 1" 1" 1" 1" 1" 1 1/4" Inlet / Outlet (ISO 7/1 – R) Ø Inlet / Outlet – OD (6) Ø mm 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 2" -- SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF UNI PPF UNI PPF UNI PPF UNI l DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg EVAPORATOR PARTIAL HEAT RECOVERY TOTAL HEAT RECOVERY 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 – 2. 33 ➜ Cooling only - EQUL PF 21 / 290 | EQUL PF MODEL 67.1 55.1 55.2 62.1 62.2 71.1 71.2 85.1 kW kW A m³/h kPa 60,3 22,2 37,9 10,4 29 50,7 17,3 31,8 8,7 36 50,8 17,3 31,8 8,7 21 57 19,7 34,9 9,8 35 56,9 19,7 35 9,8 18 59,1 21,5 38,9 10,2 35 63,4 22 39,8 10,9 20 75,6 25,7 49,1 13 37 kW kW kW A m³/h kPa 64,1 84 19,8 34,4 14,6 42 52,9 69,3 16,5 30,6 12,1 52 53,7 69,8 16,1 30,1 12,1 34 59,8 78,4 18,6 33,3 13,6 50 61,3 79,4 18,1 32,6 13,8 30 68,3 89 20,7 37,9 15,5 55 68,9 89,4 20,5 37,5 15,5 33 80,3 104 24,1 46,3 18,1 57 HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa 22,1 3,8 37,8 18,6 3,2 26,7 18,6 3,2 30,6 20,9 3,6 33,8 20,9 3,6 13 21,7 3,7 36,3 23,3 4 16,1 27,7 4,8 34,8 scroll scroll scroll scroll scroll scroll scroll scroll 1 48,5 272 1 2 44 140 2 2 44 140 2 2 50 143 2 2 50 143 2 2 62 171 2 2 62 171 2 2 68 208 2 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h CENTRIGUGAL FANS Total air flow External static pressure Max external static pressure Power input Plate current [FLA] 1 1 1 1 1 1 1 3,9 13,3 3,6 13,3 3,9 15 3,6 15,1 4,7 17,2 4,2 17,1 5,8 20,4 1 1 1 1 1 1 1 1 3,9 20,4 3,9 16,6 3,6 16,7 3,9 19 3,6 19,2 4,7 21,6 4,2 21,8 5,8 25,4 1 1 2 1 2 1 2 1 0,8 5,9 0,8 4,9 2 x 0,4 4,9 0,8 5,5 2 x 0,6 5,5 0,8 6,3 2 x 0,6 6,3 1 7,5 n. 2 2 2 2 2 2 2 3 m³/h Pa Pa kW A 21000 50 363 2,3 8,4 18000 50 589 2 9,8 18000 50 589 2 9,8 20500 50 421 2,2 8,4 20500 50 421 2,2 8,4 23000 50 308 2,9 8,4 23000 50 308 2,9 8,4 25500 50 643 2,7 14,7 R410A R410A R410A R410A R410A R410A R410A R410A 9,5 1 9,3 1 9 2 9,3 1 9 2 9,7 1 9,3 2 13,7 1 REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) 1 3,9 16,2 V/Ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 EER - Energy Efficiency Ratio kW/kW ESEER = Standard Eurovent IPLV - ARI Standard 550/590 2,46 3,56 4,02 2,62 3,92 4,35 2,63 4,31 4,78 2,61 3,93 4,36 2,6 3,73 4,14 2,42 4,04 4,48 2,55 3,71 4,11 2,67 4,41 4,89 79,5 96,7 75,9 93,1 75,9 93,1 69,6 86,8 69,6 86,8 72 89,2 72 89,2 76 93,9 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 3/1 3/2 3/1 LN 3/2 LN 360 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 2600 1200 2000 670 630 630 690 700 700 710 890 Inlet / Outlet (ISO 7/1 – R) Ø Inlet / Outlet – OD (6) Ø mm 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- -76,1 Inlet / Outlet (ISO 7/1 – R) Ø 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/2" Inlet / Outlet (ISO 7/1 – R) Ø Inlet / Outlet – OD (6) Ø mm 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- -76,1 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF UNI 2/1 PPF UNI -PPF UNI 2/1 LN PPF UNI -l 210 DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg EVAPORATOR PARTIAL HEAT RECOVERY TOTAL HEAT RECOVERY 1. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chiller water temperature 12/7°C and hot water temperature 40/45°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 – 2. 34 85.2 107.1 107.2 135.1 135.2 170.1 170.2 195.1 195.2 220.1 220.2 250.1 265.2 290.2 75,2 25,8 49,3 12,9 23 96,8 33 57,5 16,7 36 95,7 32,8 57,2 16,4 26 120 42,3 72,4 20,6 37 118 42,3 72,4 20,3 30 156 53,5 91,3 26,8 36 154 53,2 91 26,4 33 176 62,4 106 30,3 42 173 62,9 107 29,8 36 202 67,3 115 34,8 43 199 67,6 116 34,2 37 227 83,7 142 39 41 239 86,2 147 41,1 41 264 102 173 45,4 45 80,6 104 23,9 45,9 18,2 37 101 132 31,5 55,4 23 47 100 132 31,1 54,8 22,9 40 126 166 39,9 69,1 28,9 47 125 165 39,4 68,6 28,6 45 164 214 50,7 87,3 37,2 40 161 212 50,4 86,8 36,8 45 186 243 57,2 98,7 42,2 72 191 247 56,6 97,9 43 61 208 272 63,8 110 47,2 69 214 277 63,1 110 48,1 59 246 322 75,5 130 55,9 70 258 337 78,3 137 58,5 69 294 383 89,5 155 66,6 78 27,6 4,8 22,6 35,5 6,1 33,4 35,1 6,1 36,6 43,9 7,6 35,4 43,2 7,5 36,1 57,2 9,9 46,1 56,3 9,7 35,5 64,5 11,1 34,6 63,6 11 26,7 74,2 12,8 45,7 73,1 12,6 35,3 83,2 14,3 40,9 87,7 15,1 35,1 96,7 16,7 42,7 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 2 68 208 2 2 80 265 2 2 80 265 2 2 97 320,5 2 2 97 320,5 2 2 130,8 375,4 2 2 130,8 375,4 2 2 147,4 439,4 2 2 147,4 439,4 2 2 164 456 2 2 164 456 2 3 196,2 440,8 3 4 194 417,5 4 4 294,8 586,8 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5,1 20,4 5,8 25,8 6,7 25,5 7,2 32,1 6,7 31,6 8,7 41,5 8,3 40,9 11,1 46,1 9,5 46,8 17,6 53,7 15,8 52,8 17,6 60,2 20,3 63,9 20,3 70 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5,1 25,4 5,8 32,2 6,7 31,9 7,2 40,4 6,7 39,9 8,7 52,1 8,3 51,4 11,1 59 9,5 60,1 17,6 66,1 15,8 67,4 17,6 78,1 20,3 81,7 20,3 93 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 x 0,6 7,5 1,7 9,5 2 x 0,6 9,4 2,1 11,8 2 x 0,8 11,6 4 15,2 2 x 1,0 15 5,3 16,9 2 x 1,7 17,2 5,3 19,4 2 x 2,1 19,7 6,3 22 2 x 2,1 23,4 2 x 2,1 25,7 3 3 3 4 4 4 4 4 4 5 5 5 5 5 25500 50 643 2,7 14,7 32000 50 324 5 14,7 32000 50 324 5 14,7 40000 50 467 3,6 16,8 40000 50 467 3,6 16,8 52000 50 175 7,6 16,8 52000 50 175 7,6 16,8 54000 50 120 8,5 16,8 54000 50 120 8,5 16,8 62500 50 243 8,2 21 62500 50 243 8,2 21 64000 50 212 8,8 21 66000 50 147 10,1 21 66000 50 147 10,1 21 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 13,5 2 16,9 1 17,3 2 20,1 1 20,6 2 24,6 1 24,6 2 25,7 1 26 2 49,3 1 49,6 2 49,9 1 60,8 2 60,7 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,64 3,95 4,38 2,55 3,89 4,31 2,54 3,56 3,95 2,61 4,45 4,93 2,57 3,94 4,37 2,55 3,91 4,33 2,53 3,58 3,97 2,48 3,79 4,2 2,42 3,49 3,87 2,68 4,13 4,58 2,62 3,81 4,23 2,46 4,31 4,78 2,48 3,68 4,08 2,35 3,55 3,94 76 93,9 80,8 98,7 80,8 98,7 74 92,6 74 92,6 77,3 95,9 77,3 95,9 78 96,6 78 96,6 77,3 96,6 77,3 96,6 77,7 96,9 78,1 97,4 78,1 97,4 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 2600 1200 2000 2600 1200 2000 2600 1200 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 4950 1260 2040 4950 1260 2040 4950 1260 2040 4950 1260 2040 4950 1260 2040 890 1080 1080 1460 1460 1550 1550 1600 1600 1970 1970 2140 2290 2340 -76,1 -76,1 -76,1 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" -76,1 -76,1 -76,1 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 35 Air Cooled Chiller | EQSL 300 / 1310 cooling only Screw ooling Capacity from 299 to 808 KW C Size = 20 Refrigerant : R-134a EER up to 2,79 ESSEER up to 3,34 Main Functions: Available with 2 cooling circuits 2 SCREW compressors mounted on rubber pad Modern design and modular Shell and tube evaporator Available Versions: Main accessories and options artial heat recovery P Total heat recovery Extra low noise EC fan version Brine Low ambiant operation up to -10°C STD) Product Advantages arge cooling capacity range with SCREW technology with a maximum reliability L Screw compressors per circuit for a highest efficiency and reliability Electronic Expansion valve STD Linear step capacity control Screen display with graphics symbols for an easy reading Choice of the sound level Total or partial heat recovery Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. (°C) Evaporator outlet temperature 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -10 -13 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45(°C) Ambiant air temperature 36 Code 101 118 119 143 150 151 170 172 175 351 450 451 550 605 650 731 739 740 769 770 919 923 926 931 932 934 942 943 EC Fan Brine version kit A Brine version kit B Glycol free LNO Kit Kit ELN Spring antivibration holders Rubber support (kit) Coils with pre painted fins Desuperheater 100% Heat Reclaim Stop valve on compressor suction line Compr. Power factor capcitor 0,9 Compressor thermal relays Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group 1 pump + 1 pump stdby Pumping group 2 pumps + 1 pump stdby Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger Data logger EQSL MODEL 300 320 360 390 430 480 kW kW A m³/h kPa 299 96 162 51,3 47 315 102 163 54,1 52 335 116 200 57,5 48 391 125 208 67,1 59 430 140 237 73,9 54 476 157 261 81,8 38 kW kW kW A m³/h kPa 294 394 100 168 68,5 62 311 417 105 167 72,4 50 333 451 118 202 78,4 61 386 515 129 213 89,5 63 429 570 140 238 99 92 476 633 157 262 108 94 HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa 59,5 10,2 6,6 62,7 10,8 7,3 66,7 11,5 8,2 77,8 13,4 8,9 85,6 14,7 4,4 94,7 16,3 4,1 twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew 2 201,8 403,9 25…100% 2 205 382,5 25…100% 2 235,6 468,8 25…100% 2 269,6 629,8 25…100% 2 288,2 639,1 25…100% 2 309,3 790,1 25…100% 1 1 1 1 1 1 113 63 113 63 113 63 160 90 160 90 150 95 2 2 2 2 2 2 28 78 32 90 32 90 38 108 38 108 38 108 2 2 2 2 2 2 5 20 5 20 5 20 5 20 6,8 30 6,8 30 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity n. Maximum current A Starting current A Capacity steps EVAPORATOR (shell and tube) n. Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h AXIAL FANS n. 6 6 6 8 8 8 135498 11,6 23,4 135498 11,7 23,4 135498 11,7 23,4 180664 15,4 31,2 180664 15,4 31,2 180664 15,4 31,2 R134a R134a R134a R134a R134a R134a 110 2 146 2 146 2 145 2 145 2 145 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,78 3,06 2,77 3,03 2,62 3,2 2,78 3,18 2,77 3,1 2,76 3,13 73,1 92,9 71,7 91,4 72 91,8 71,6 91,9 76 96,2 76,2 96,4 GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- Length mm Width mm Height mm 3520 2260 2550 3520 2260 2550 3520 2260 2550 4490 2260 2550 4490 2260 2550 4490 2260 2550 kg 3992 4258 4411 4544 4753 4890 Ø mm 141,3 141,3 141,3 168,3 168,3 168,3 Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" Ø Ø mm 2 x 2" -- 2 x 2" -- 2 x 2" -- 2 x 2 1/2" -- 2 x 2 1/2" -- 2 x 2 1/2" -- Total air flow m³/h Power input kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER - Eurovent Standard SOUND LEVEL Average sound pressure level [LPm](4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP 1 pump in operation 2 pumps in operation 1 pump in operation + 1 reserve pump 2 pumps in operation + 1 reserve pump GE GE GE GE DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet – OD PARTIAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M TOTAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M Inlet/outlet – OD 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chilled water temperature 12/7°C; hot water inlet temperature at 40°C. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 37 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2. ➜ Cooling only - EQSL 300 / 1310 | EQSL MODEL 530 540 560 610 650 kW kW A m³/h kPa 523 174 286 89,8 38 543 180 297 93,3 41 563 186 309 96,7 45 611 204 332 105 51 645 217 354 111 56 kW kW kW A m³/h kPa 527 699 171 281 118 81 551 726 175 290 126 63 568 750 183 305 130 69 620 818 198 323 132 71 668 870 203 333 151 69 HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa 104 17,9 3,8 108 18,6 3,5 112 19,2 2,6 121 20,9 3,1 128 22,1 2,8 COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS twin-screw twin-screw twin-screw twin-screw twin-screw Quantity n. Maximum current A Starting current A Capacity steps EVAPORATOR (shell and tube) n. Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h AXIAL FANS n. Total air flow m³/h Power input kW Plate current [FLA] A REFRIGERANT 2 330,4 811,2 25…100% 2 348,6 526,2 25…100% 2 366,8 544,4 25…100% 2 390,4 544,4 25…100% 2 414 568 25…100% 1 1 1 1 1 150 95 143 100 143 100 256 127 256 127 2 2 2 2 2 42 118 46 132 46 132 46 132 58 156 2 2 2 2 2 6,8 30 6,8 30 6,8 30 8,6 35 10,4 40 8 8 8 8 8 180664 15,4 31,2 177924 15,5 31,2 175184 15,6 31,2 175184 15,6 31,2 175184 15,6 31,2 R134a R134a R134a R134a R134a 145 2 170 2 194 2 194 2 194 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,76 3,17 2,78 3,23 2,79 3,21 2,78 3,17 2,77 3,24 76,4 96,7 76,4 96,7 76,4 96,7 78 98,2 79,2 99,4 GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- Length mm Width mm Height mm 4490 2260 2550 4490 2260 2550 4490 2260 2550 4490 2260 2550 4490 2260 2550 kg 5012 5117 5221 5321 5241 168,3 168,3 168,3 168,3 168,3 Inlet/outlet – ISO228/1-G M Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" Inlet/outlet – ISO228/1-G M Ø Inlet/outlet – OD Ø mm 2 x 2 1/2" -- 2 x 2 1/2" -- 2 x 2 1/2" -- 2 x 2 1/2" -- 2 x 3" -- Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER - Eurovent Standard SOUND LEVEL Average sound pressure level [LPm](4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP 1 pump in operation 2 pumps in operation 1 pump in operation + 1 reserve pump 2 pumps in operation + 1 reserve pump GE GE GE GE DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet – OD Ø mm PARTIAL HEAT RECOVERY TOTAL HEAT RECOVERY 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chilled water temperature 12/7°C; hot water inlet temperature at 40°C. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 38 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2. 710 770 850 910 950 1060 1120 1180 1310 707 237 377 121 63 768 258 400 132 73 853 289 456 147 55 905 303 479 156 63 949 320 515 163 71 1063 355 597 183 41 1121 375 634 193 45 1181 396 680 203 49 1310 443 742 225 59 718 948 230 366 156 78 783 1031 248 385 179 81 878 1151 273 432 200 86 924 1214 290 459 211 86 979 1277 298 482 222 82 1081 1425 344 579 248 105 1159 1511 353 599 263 74 1227 1595 368 638 277 81 1357 1770 414 697 308 86 141 24,2 2,7 153 26,3 3,2 170 29,2 2,6 180 31 2,5 189 32,5 3,3 212 36,4 4,1 223 38,4 4,6 235 40,5 5,1 261 44,9 6,2 twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw 2 444,1 581 25…100% 2 474,2 611,1 25…100% 2 535,8 720,9 25…100% 2 567,4 826,7 25…100% 2 615,4 902,7 25…100% 2 709,6 1057,8 25…100% 2 753,6 1137,8 25…100% 2 797,6 1181,8 25…100% 2 896 1324 25…100% 1 1 1 1 1 1 1 1 1 256 127 247 143 238 154 223 172 223 172 382 208 382 208 370 220 359 241 2 2 2 2 2 2 2 2 2 58 156 64 180 72 204 80 228 88 252 88 252 100 284 100 284 114 326 2 2 2 2 2 2 2 2 2 10,4 40 10,4 40 15,8 50 15,8 50 19,4 50 23 50 25,7 60 28,4 60 35,6 60 9 10 10 12 12 16 16 16 16 197082 17,6 35,1 218980 19,5 39 212690 20,1 39 262776 23,4 46,8 262776 23,4 46,8 361328 30,9 62,4 361328 30,9 62,4 361328 30,9 62,4 350368 31,2 62,4 R134a R134a R134a R134a R134a R134a R134a R134a R134a 241 2 241 2 302 2 289 2 289 2 290 2 290 2 290 2 389 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,78 3,18 2,77 3,18 2,76 3,19 2,77 3,26 2,76 3,32 2,75 3,29 2,76 3,34 2,77 3,32 2,76 3,3 79,4 100,1 80 100,7 79,7 100,4 78,8 99,8 78,8 99,8 81,1 102,9 81,1 102,9 81,1 102,9 81,4 103,2 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 5460 2260 2550 5460 2260 2550 5460 2260 2550 6430 2260 2550 6430 2260 2550 8720 2260 2550 8720 2260 2550 8720 2260 2550 8720 2260 2550 6232 6517 7032 7354 7414 9491 9975 9995 10075 168,3 219,1 219,1 219,1 219,1 219,1 219,1 219,1 273 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- -2 x 114,3 39 Air Cooled Chiller | EQSLA 290 / 1510 Energy Class classA More efficient A+ A B C D E cooling only Screw CLASS A Less efficient F G ooling Capacity from 283 to 1510 KW C Size = 26 Refrigerant : R-134a EER up to 3,38 ESSEER up to 3,95 classA Main Functions: vailable with 2 cooling circuits A 2 SCREW compressors mounted on rubber pad Modern design and modular Shell and tube evaporator Main accessories and options Available Versions: artial heat recovery P Total heat recovery Extra low noise EC fan version Brine Low ambiant operation up to -10°C STD) Product Advantages lassA = high energy efficiency c Large cooling capacity range with SCREW technology with a maximum reliability Compressors screw per circuit for a highest efficiency and reliability Electronic Expansion valve STD Linear step capacity control Screen display with graphics symbols for an easy reading Choice of the sound level Total or partial heat recovery Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. (°C) Evaporator outlet temperature 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -10 -13 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45(°C) Ambiant air temperature 40 Code 101 118 119 143 150 151 170 171 351 450 451 550 605 650 731 739 740 769 770 919 923 926 931 932 934 942 943 EC Fan Brine version kit A Brine version kit B Glycol free LNO Kit Kit ELN Spring antivibration holders Rubber antivibration holders Coils with pre painted fins Desuperheater 100% Heat Reclaim Stop valve on compressor suction line Compr. Power factor capcitor 0,9 Compressor thermal relays Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group 1 pump + 1 pump stdby Pumping group 2 pumps + 1 pump stdby Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQSLA MODEL 290 300 320 340 360 400 450 kW kW A m³/h kPa 283 76,8 133 48,7 12 300 83 140 51,5 17 319 87,1 148 54,8 19 340 92 157 58,4 21 358 97 157 61,4 17 399 110 192 68,5 13 446 122 212 76,6 17 kW kW kW A m³/h kPa 264 348 83,8 142 60,4 48 289 380 91,1 151 66 58 310 404 94,2 158 70,3 39 326 428 102 170 74,4 42 345 453 107 168 78,7 55 388 507 119 204 88,1 57 433 565 132 227 98,2 42 HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa 56,4 9,7 5,9 59,7 10,3 6,6 63,6 10,9 7,5 67,7 11,7 6,7 71,2 12,3 3 79,4 13,7 2,9 88,8 15,3 2,8 twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew 2 163 350 25…100% 2 179 356 25…100% 2 190 392 25…100% 2 201 403 25…100% 2 205 382 25…100% 2 235 468 25…100% 2 269 629 25…100% COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity n. Maximum current A Starting current A Capacity steps EVAPORATOR (shell and tube) n. Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h AXIAL FANS n. 1 1 1 1 1 1 1 113 63 107 72 107 72 107 72 160 90 157 90 150 95 2 2 2 2 2 2 2 24 66 28 78 32 90 32 90 32 90 38 108 46 132 2 2 2 2 2 2 2 3,2 20 3,2 20 4,1 20 5 20 5 20 5 20 5 20 6 6 7 8 8 8 10 131388 11,7 23,4 127614 12,1 23,4 153286 13,7 27,3 175184 15,6 31,2 170152 16,1 31,2 170152 16,1 31,2 212690 20,1 39 74 2 74 2 96 2 96 2 96 2 145 2 120 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,2 3,55 3,16 3,52 3,17 3,53 3,16 3,53 3,17 3,51 3,16 3,52 3,14 3,51 72,3 92 72,8 92,5 72,5 92,7 72,7 92,9 71,3 91,5 71,7 91,9 71,4 92,1 GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- Length mm Width mm Height mm 3520 2260 2550 3520 2260 2550 4490 2260 2550 4490 2260 2550 4490 2260 2550 4490 2260 2550 5460 2260 2550 kg 3738 4109 4515 4520 4697 4902 5428 Ø mm 141,3 141,3 141,3 141,3 168,3 168,3 168,3 Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" Ø Ø mm 2 x 2" -- 2 x 2" -- 2 x 2" -- 2 x 2" -- 2 x 2" -- 2 x 2 1/2" -- 2 x 2 1/2" -- Total air flow m³/h Power input kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER - Eurovent Standard SOUND LEVEL Average sound pressure level [LPm](4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP 1 pump in operation 2 pumps in operation 1 pump in operation + 1 reserve pump 2 pumps in operation + 1 reserve pump GE GE GE GE DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet – OD PARTIAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M TOTAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M Inlet/outlet – OD 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chilled water temperature 12/7°C; hot water inlet temperature at 40°C. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 41 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2. ➜ Cooling only - EQSLA 290/ 1510 | EQSLA MODEL 480 520 570 620 660 700 760 kW kW A m³/h kPa 472 129 222 81 17 518 144 243 88,9 17 565 159 264 97 24 614 172 289 105 49 654 184 306 112 33 695 196 323 119 38 761 215 328 131 44 kW kW kW A m³/h kPa 458 598 140 238 104 42 503 659 156 260 115 42 554 720 166 274 125 50 604 782 178 298 136 56 647 836 189 313 145 61 684 887 203 334 154 60 749 971 222 339 169 63 HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa 93,9 16,2 2,6 103 17,8 2,2 112 19,4 2,6 122 21 2,5 130 22,4 2,3 138 23,8 2,6 151 26,1 2,1 twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew 2 288 639 25…100% 2 309 790 25…100% 2 330 811 25…100% 2 366 544 25…100% 2 390 568 25…100% 2 414 568 25…100% 2 444 598 25…100% COOLING ONLY (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop COOLING + TOTAL HEAT RECOVERY (2) COOLING CAPACITY HEATING CAPACITY Compressors power input Compressors operating current [OA] Heat recovery water flow rate Heat recovery pressure drop PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity n. Maximum current A Starting current A Capacity steps EVAPORATOR (shell and tube) n. Water volume l Max water flow rate m³/h TOTAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h AXIAL FANS n. 1 1 1 1 1 1 1 143 100 256 127 256 127 256 127 247 143 247 143 223 172 2 2 2 2 2 2 2 46 132 46 132 58 156 58 156 64 180 64 180 72 204 2 2 2 2 2 2 2 6,8 30 6,8 30 6,8 30 6,8 30 8,6 35 10,4 40 10,4 40 10 10 10 10 11 12 13 212690 20,1 39 212690 20,1 39 212690 20,1 39 212690 20,1 39 244303 21,3 42,9 262776 23,4 46,8 284674 25,4 50,7 181 2 181 2 181 2 181 2 217 2 217 2 252 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,17 3,51 3,16 3,55 3,15 3,52 3,2 3,62 3,18 3,55 3,17 3,56 3,17 3,52 75,5 96,2 75,8 96,4 76 96,7 76 96,7 78,2 99,3 79,4 100,4 79,7 101,1 GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- GE80/1 -GE80/2 -- -GE80/11 -GE80/21 Length mm Width mm Height mm 5460 2260 2550 5460 2260 2550 5460 2260 2550 5460 2260 2550 6430 2260 2550 6430 2260 2550 7400 2260 2550 kg 5662 5999 6121 6112 6733 6743 7404 Ø mm 168,3 168,3 168,3 168,3 219,1 219,1 219,1 Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" Ø Ø mm 2 x 2 1/2" -- 2 x 2 1/2" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- Total air flow m³/h Power input kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER - Energy Efficiency Ratio kW/kW ESEER - Eurovent Standard SOUND LEVEL Average sound pressure level [LPm](4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP 1 pump in operation 2 pumps in operation 1 pump in operation + 1 reserve pump 2 pumps in operation + 1 reserve pump GE GE GE GE DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet – OD PARTIAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M TOTAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M Inlet/outlet – OD 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to chilled water temperature 12/7°C; hot water inlet temperature at 40°C. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 42 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2. 830 870 920 980 1020 1090 1150 1280 1350 1430 1470 1510 826 233 333 142 51 871 248 375 150 56 916 262 418 157 61 974 274 435 167 68 1020 287 464 175 76 1084 305 504 186 71 1148 322 544 197 79 1276 359 611 219 54 1352 385 652 232 41 1430 411 693 246 44 1474 406 685 253 35 1510 398 672 259 35 811 1053 242 346 183 72 860 1115 255 385 194 71 910 1176 266 423 204 69 962 1244 281 446 216 76 1018 1306 288 466 227 53 1078 1386 308 508 241 60 1138 1466 327 552 255 66 1265 1630 365 620 283 72 1348 1735 388 656 302 77 1435 1843 408 688 320 55 1458 1869 411 692 325 57 1483 1896 413 696 329 57 164 28,3 2 173 29,8 2,8 182 31,4 3 194 33,4 3,4 203 35 3,8 216 37,1 4,3 228 39,3 4,6 254 43,7 5,7 269 46,4 6,3 285 49 7 293 50,5 7,5 301 51,8 7,7 twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew 2 474 611 25…100% 2 505 690 25…100% 2 535 720 25…100% 2 567 826 25…100% 2 615 902 25…100% 2 662 1010 25…100% 2 709 1057 25…100% 2 797 1181 25…100% 2 846 1274 25…100% 2 896 1324 25…100% 2 896 1324 25…100% 2 896 1324 25…100% 1 1 1 1 1 1 1 1 1 1 1 1 382 208 382 208 382 208 382 208 348 265 348 265 348 265 348 265 620 407 620 407 620 407 620 407 2 2 2 2 2 2 2 2 2 2 2 2 72 204 80 228 88 252 88 252 100 284 100 284 100 284 114 326 126 362 132 386 132 386 132 386 2 2 2 2 2 2 2 2 2 2 2 2 10,4 40 13,1 45 15,8 50 15,8 50 19,4 50 21,2 50 23 50 28,4 60 32 60 35,6 60 35,6 60 35,6 60 14 14 14 16 16 18 20 20 20 20 22 24 306572 27,3 54,6 302169 27,7 54,6 297766 28,1 54,6 350368 31,2 62,4 350368 31,2 62,4 401014 34,9 70,2 451660 38,6 78 437960 39 78 431670 39,6 78 425380 40,2 78 467918 44,2 85,8 510456 48,2 93,6 252 2 295 2 337 2 290 2 290 2 326 2 362 2 362 2 412 2 462 2 530 2 578 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,17 3,5 3,16 3,49 3,16 3,51 3,19 3,55 3,21 3,68 3,19 3,69 3,18 3,68 3,21 3,69 3,18 3,68 3,17 3,72 3,27 3,83 3,38 3,95 80,3 101,7 80,1 101,6 80 101,4 78,1 99,9 78,1 99,9 79,5 101,7 81,5 103,9 81,5 103,9 81,7 104,1 81,8 104,2 81,6 104,2 81,3 104,2 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE80/11 -GE80/21 -GE100/11 -GE100/21 -GE100/11 -GE100/21 -GE100/11 -GE100/21 7400 2260 2550 7400 2260 2550 7400 2260 2550 8720 2260 2550 8720 2260 2550 9690 2260 2550 10660 2260 2550 10660 2260 2550 10660 2260 2550 10660 2260 2550 11630 2260 2550 12600 2260 2550 8139 8341,5 8544 9195 9318 10274 11180 11362 11972 12292 12931 13090 219,1 219,1 219,1 219,1 273 273 273 273 323,9 323,9 323,9 323,9 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- -2 x 114,3 -2 x 114,3 -2 x 114,3 -2 x 114,3 -2 x 114,3 43 Air Cooled Chiller | MQHD STAR 06 / 018 Heat pump Scroll Compressor R410A ❯❯Cooling capacity from 2,4 to 18 KW ❯❯Heating capacity from 1,8 to 18 KW ❯❯COP up to 4,4 ❯❯EER up to 4,6 ❯❯Refrigerant : R410A ❯❯Tailles = 3 Main Functions: ❯❯Compressor DCI INVERTER ❯❯Management domestic hot water ❯❯Leaving hot water temperature up to 55°C ❯❯Compatible floor heating ❯❯Modbus protocol RS 485 ❯❯All season operation ❯❯Eurovent certified Main accessories and options 7ACFH0666 7ACFH0278 7ACFH0663 7ACFH0662 7ACFH0665 232617 7ACTL0472 ❯❯Decanting filter ❯❯Water filter ❯❯Water tank 140 L ❯❯300-litre domestic hot water tank ❯❯6 kW electric heater in line ❯❯Wired ambient thermostat ❯❯Shock-absorbing support feet Product Advantages ❯❯Inverter techno ❯❯Inverter technology on fan motor ❯❯Electronic expansion valve on standard ❯❯Low sound level ❯❯operating up -15°C external temperature ❯❯Leaving hot water temperature up to 55°C ❯❯Integratd water circulator ❯❯Integrated expansion tank 2 liters ❯❯Water law compensation via 0/10V ❯❯Blue fins hydrofilic ❯❯On / Off remote ❯❯Alarm remote ❯❯COOL/HEAT remote mode ❯❯Water differential pressure switch STD ❯❯Condenser coil grils STD Fixed speed system Conventional technoly: The compressor rotates at a fixed speed and adjusts the power requirements through ON/OFF cycles Inverter system The set point is reached quickly and compressor adjusts the power constantly as required. THE TIME FOR REACHING THE REQUIRED TEMPERATURE IS REDUCED BY 30% WITH A DC INVERTER SYSTEM INSIDE TEMPERATURE Energy savings INSIDE TEMPERATURE High power Consumption REQUIRED TEMPERATURE WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Max leaving water temperature A40 Min leaving water temperature A41 Max external air temperature Min external air temperature DC INVERTER SYSTEM 5°C 20°C 46°C / 10°C -10°C STARTING THE UNIT La technologie Inverter permet d’obtenir un très haut rendement saisonnier, de participer à réduire les émissions de CO2 et d’économiser sur les coûts d’entretien annuels tout en procurant un très grand confort. heating Mode Max leaving water temperature A15 Min leaving water temperature A-15 Min external air temperature Max external air temperature at W55 TIMES FIXED SPEED SYSTEM 55°C 55°C -15°C 35°C 44 MQHD STAR MQHD08 MQHD12 MQHD16 CODE 7OG012287 Nominal Cooling Capacity A35W18 kW 8 7OG012290 12,25 16,00 Nominal Power Input kW EER Energy efficiency class 2,85 4,30 A 4,15 3,86 A 2,13 3,75 A Nominal Cooling Capacity A35W7 kW 6,8 Nominal Power Input kW EER 2,43 2,8 7OG012292 11,44 14,50 4,02 2,85 5,37 2,70 Nominal Heating Capacity A7W35 kW 7,7 12,01 15,50 Nominal Power Input kW Max Power Input kW C.O.P. Energy efficiency class 2,79 6,50 4,31 A 3,88 6,50 4,00 B 1,97 3,2 3,9 B Nominal Heating Capacity A7W45 kW 7;00 Nominal Power Input kW C.O.P. 2,26 3,1 11,75 15,30 3,55 3,31 4,77 3,21 400/3/50 400/3/50 Power Supply V-ph-Hz 230/1/50 Rated current (Cooling) Rated current (heating) Started current Circuit breaker rating A 8,9 4,8 6,3 A 9,1 4,9 6,8 A A 15 20 15 20 15 20 2 2 2 variable variable variable 0,135 0,077 0,077 kg 1,76 2,7 3,2 kPa 50 151 134 m /hr 1,23 2,06 2,75 pouces 3/4 3/4 1 pouces 3/4 3/4 1 950 340 864 82 1241 401 1382 185 1241 401 1382 190 64 69 70 Components Refrigerant control Compressor Expansion tank l capacity Condenser Condenser type & quantity Fan type & quantity Fan speeds H RPM Rated current fan KW motor unit Evaporator Evaporator type & quantity Standard charge(R410a) Available Water Pressure Water flow Hydraulic Connection (Inlet Water) Hydraulic Connection (Outlet Water) 3 Dimensions and Weight Lenght Widht Height Weight mm mm mm kG Sound level Nominal comp f [dBA] Sound power level All data are according to Eurovent Standard. 45 Air Cooled Chiller | AQAH 25/40 Heat pump NEWS Scroll R410A ooling Capacity from 25 to 37 KW C Heating Capacity from 27 to 40 KW Size = 4 Refrigerant : R410A EER up to 2.97 ESSEER up to 4 COP up to 3,04 Main Functions: Available with one cooling circuit Tandem scroll per refrigerant circuit Extented working limits Heat Pump operating function Leaving hot water up to 55°C Main accessories and options Code Available Versions: ow sound level Standard L High temperature operation up to 50°C Return or leaving water temperature control With Hydraulic kit as STD Product Advantages perating heating mode up to -15°C O Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 L/KW Low footprint Easy maintenance Low water pressure drop Set point compensation as STD Night mode (extra low sound level) std ON OFF Remote Remote heat cool mode Water flow switch factory mounted STD Water filter STD (not mounted) Phase monitor STD Few options, maximum features as STD WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External Max air temperature External Min air temperature 5/18°C 2/18°C 50°C -10°C Heating mode Leaving water temperature max External Max air temperature External Min air temperature 55°C +20°C -15°C 46 HP/BP Manometers Kit interface modbus Low temperature kit (-15°C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 1 pump medium pressure as standard Rubber antivibration pad Water level pressure switch External water tank HEAT PUMP VERSION STD AQAH 25 30 35 40 25,3 26,9 35,8 36,8 8,6 9,3 13,2 13,6 Total EER 100% * * 2,94 2,88 2,71 2,70 ESEER * * 3,78 3,77 3,88 3,71 Heating Capacity kW 26,9 29,95 37,3 40,4 Power input kW 9,28 9,92 13,23 13,2 2,91 3,02 2,82 3,04 C B C B AQUALOGIC II Cooling Capacity kW Power input kW Total COP 100% * ** Class Electrical power 400V/3ph/50 Hz Direct Direct Direct Direct Nominal current A Start up type 15,1 16,3 24 24 Maximum operating current A 18,2 21 29,6 30 61 75 115 118 1 1 1 1 8,2 8,4 9,1 9,2 1 2 2 2 Scroll Scroll Scroll Scroll 0/50/100 0/50/100 0/50/100 0/50/100 40 70 70 70 Inrush current A REFRIGERANT Type Quantity cooling cicuits Charge kg R410A COMPRESSEURS Quantity cooling cicuits Type N° capactity steps % Cranckcrease heater W EVAPORATEUR Quantity 1 1 1 1 Plaques Plaques Plaques Plaques 4,3 4,6 6,1 6,3 37 22 37 37 1,78 2,55 2,55 2,55 30 30 30 30 1 1 1 1 2,4 2,4 2,8 2,8 Row quantity 2 2 2 2 Quantity 1 1 1 1 13800 13800 16000 16000 930 930 650 650 620 620 900 900 STD STD STD STD 1 1 1 1 Inlet Diameter pouces 1"1/2 1"1/2 1"1/2 1"1/2 Outlet diameter pouces 1"1/2 1"1/2 1"1/2 1"1/2 Length mm 1000 1000 1000 1000 Width mm 1000 1000 1000 1000 height mm 1983 1983 1983 1983 300 330 340 340 75 75 76 76 Type Water flow rate m³/h Water pressure drop kPa Water volume l Antifreeze heater W Coil Quantity Exchange surface m2 Fan motors Air flow m³/h Rotation speed tr/mn power input (unitary) W Pumps Quantity Power input Kw Available static pressure Kpa Hydraulic connexion Type Dimensions Weight Opérating weight kg Sound Level Niveau de puissance sonore (*) dB(A) (*)Following Eurovent standard. (**) Followingt Eurovent 14511 47 Air Cooled Chiller | AQAH 45/125 Heat pump NEWS Scroll R410A ooling Capacity from 46 to 122 KW C Heating Capacity from 50 to 120 KW Size = 7 Refrigerant : R410A EER up to 3 ESSEER up to 4 COP up to 3,06 Main Functions: vailable with one cooling circuit A Tandem scroll per refrigerant circuit Extented working limits Heat Pump operating function Leaving hot water up to 55°C Main accessories and options Code Available Versions: ow sound level Standard L High temperature operation up to 50°C Return or leaving water temperature control With or without Hydraulic kit Product Advantages Operating heating mode up to -15°C Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 L/KW Low footprint Easy maintenance Low water pressure drop Set point compensation as STD Night mode (extra low sound level) std ON OFF Remote Remote heat cool mode Water flow switch factory mounted STD Water filter STD (not mounted) Phase monitor STD Few options, maximum features as STD WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External Max air temperature External Min air temperature 5/18°C 2/18°C 50°C -10°C Heating mode Leaving water temperature max External Max air temperature External Min air temperature 55°C +20°C -15°C 48 HP/BP Manometers Kit interface modbus Low temperature kit (-15°C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 1 pump medium pressure Rubber antivibration pad Water level pressure switch Water tank Complete Hydraulic kit 2 pumps medium pressure HEAT PUMP VERSION STD AQAH 45 55 65 75 90 105 125 AQUALOGIC II Cooling Capacity kW Power input kW 46,8 53,3 65,8 71,6 91,4 106,0 122 16,89 19,66 22,1 23,8 34,36 38,0 46,4 Total EER 100% * * 2,77 2,71 2,97 3 2,66 2,79 2,63 ESEER * * 3,87 3,89 4 3,97 3,82 3,85 3,83 119 Heating Capacity kW Power input kW Total COP 100% * ** Class 50 58,4 69,6 75,9 88 101,0 17,85 20,42 22,7 24,3 33,72 38,4 45,4 2,8 2,86 3,06 3,12 2,62 2,63 2,62 C C B B D D D Electrical power 400V/3ph/50 Hz Start up type Nominal current A Maximum operating current A Inrush current A Direct Direct Direct Direct Direct Direct Direct 30 35 42 47 62 69 84 34 39 52 57 67 77 92 126 134 195 201 250 300 330 1 1 1 1 1 1 1 14 14,3 18,9 19,3 22,0 32,3 33 2 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Scroll 0/50/100 0/40/60/100 0/40/60/100 0/45/55/100 0/45/55/100 0/38/62/100 0/33/67/100 2*90 2*90 2*90 2*90 90/120 90/140 90/140 REFRIGERANT Type Quantity cooling cicuits Charge kg R410A COMPRESSEURS Quantity cooling cicuits Type N° capactity steps % Cranckcrease heater W EVAPORATEUR Quantity Type Water flow rate m³/h Water pressure drop kPa Water volume l Antifreeze heater W 1 1 1 1 1 1 1 Plaques Plaques Plaques Plaques Plaques Plaques Plaques 20,9 8 9,1 11,3 12,3 15,7 18,2 27 35 28 33 26 34 45 4,1 4,1 6,1 6,1 10,8 10,8 10,8 30 30 2*30 2*30 2,30 2*30 2*30, 1 1 2 2 2 2 2 4,2 4,2 5,55 5,55 6,4 6,4 6,4 2 2 2 2 2 3 3 2 Coil Quantity Exchange surface m2 Row quantity Fan motors Quantity Air flow m³/h Rotation speed tr/mn power input (unitary) W 1 1 2 2 2 2 23500 23500 30000 30000 42000 42000 42000 900 900 630 630 900 900 900 1800 1800 800 800 1800 1800 1800 Pumps Quantity OPTION 1 ou 2 POMPES Power input Kw OPTION 1 ou 2 POMPES Available static pressure Kpa OPTION 1 ou 2 POMPES Hydraulic connexion Type Male GAS Threaded Inlet Diameter pouces 2" 2" 2" 2" 2"1/2 2"1/2 2"1/2 Outlet diameter pouces 2" 2" 2" 2" 2"1/2 2"1/2 2"1/2 Dimensions Length mm 2180 2180 2180 2180 2180 2180 2180 Width mm 1160 1160 1160 1160 1160 1160 1160 height mm 1986 1986 1986 1986 2286 2286 2286 510 510 580 580 890 1000 1020 79 79 79 79 82 82 82 Weight Opérating weight kg Sound Level Niveau de puissance sonore (*) dB(A) (*)Following Eurovent standard. (**) Followingt Eurovent 14511 49 Air Cooled Chiller | AQCH 25-80 Heat pump Scroll Ductable Cooling capacity: from 25 to 80 kW Refrigerant: r407c Sizes: 8 Main Functions: 2 scroll compressors/1 refrigerant circuit Centrifugal Fans Product Advantages Scroll compressors. Brazed stainless steel plate heat exchangers. Microprocessor based iltc control. r407c refrigerant. Compact units taking up the strict minimum of ground surface area, for easy installation. “Plug and Play” design with an integrated hydraulic module for minimising installation costs. Accessibility: easy access to all components, thanks to panels removable by screws, thus significantly reducing unit maintenance times. WORKING LIMITS (to be confirmed following selection software issue) COOLING MODE Leaving water temperature without glycol Outdoor air temperature 5/18°C 15/46°C -7/46°C(with optional fan speed control) HEATING MODE Leaving water temperature without glycol Outdoor air temperature 25/50°C -5/20°C 50 Main accessories and options nti-vibration pads: rubber anti-vibration pads, to A be fitted on site by the installer. Anti-vibration mounts: Visible spring anti-vibration mounts, for on site fitting by the installer. Compressor jacket: Supplied fitted. Condenser coil protective coating: - aluminium fins with hydrophilic coating, - aluminium fins with polyurethane coating. High static motor. Remote control terminal: Hard-wired control enabling the unit’s Start/Stop functions to be controlled remotely. Low ambient kit (-7°c): Factory-fitted option consists of frequency inverter acting on the motor in order to keep fan speed under control. Chiller sequencer: Supplied loose, it allows a control up to 4 units. Water isolating valves: Supplied loose. Water flow switch: Factory-installed option for models 25 to 35. Double water pump: Supplied with a control and power supply remote panel. the electrical supply of the latter is to be carried out by others during installation. Inlet air duct collar. AQCH - siZes COOLING CAPACITy kW Power input (compressor) kW HEATING CAPACITy kW Power input (compressor) kW 25 30 35 40 50 60 70 80 2,9 28,8 33,7 39,6 46,2 56,3 67,5 76,5 11,5 12,9 13,5 16,2 22,0 25,8 28,1 31,6 27/06/12 32,2 36,3 43,9 55,4 64,2 76,2 84,0 11,5 12,9 13,5 16,2 22,0 25,8 28,1 31,6 Power supply Startup type 400V/3+N/50Hz Direct Direct Direct Direct Direct Direct Direct Direct 1 2 3 4 5 6 7 8 2 2 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll 1 1 1 1 1 1 1 1 Plate Plate Plate Plate Plate Plate Plaque Plaque number 1 1 1 1 1 1 1 1 number 2 2 2 2 2 2 2 2 inlet/outlet diameter pouces 1"1/2 1"1/2 1"1/2 2" 2" 2" 2" 2" operating with pump kg 385 410 425 570 640 660 865 920 operating without pump kg 385 410 425 570 640 660 865 920 length mm 1752 1752 1752 2206 2206 2206 2464 2464 Width mm 890 890 890 890 890 890 1100 1100 Height mm 1505 1505 1505 1773 1773 1773 2313 2313 81 81 81 80,8 86,1 86,1 83,3 83,3 REFRIGERANT Type number of refrigerant circuit R407C COMPRESSORS number Type EVAPORATOR number Type COIL FANS WATER CONNECTIONS Type Gas threaded WEIGHT DIMENSIONS ACOUSTICAL DATA (NORMAL MODE) Sound power level dB(A) (1) Values are based on chilled water inlet/outlet temperature of 12/7°C and an outdoor temperature of35°C. 51 Air Cooled Chiller | EQPH 128 / 830 Heat pump Scroll R410A ❯❯Cooling Capacity from 117 to 772 KW ❯❯Heating capacity from 132 to 932 KW ❯❯Size = 26 ❯❯Refrigerant : R410A ❯❯EER up to 2,74 ❯❯ESSEER up to 4,18 ❯❯COP up to 3,18 Main Functions: ❯❯Available with 1, 2, 3, or 4 cooling circuits ❯❯Tandem scroll per refrigerant circuit ❯❯Modern design and modular ❯❯Shell and tube evaporator from the size 430 Main accessories and options Available Versions: ❯❯Partial heat recovery ❯❯Extra low noise ❯❯EC fan version ❯❯Brine ❯❯Low ambiant operation up to -10°C STD Product Advantages ❯❯Large cooling capacity range with scroll technology with a maximum reliability thanks to the multi circuit ❯❯Tandem scroll compressors per circuit for a highest efficiency and reliability ❯❯Electronic Expansion valve STD ❯❯High COP ❯❯Screen display with graphics symbols for an easy reading ❯❯Choice of the sound level ❯❯EC fan motor for available static pressure ❯❯Remote demand limit via additional elec board ❯❯Analog set point compensation ❯❯Eurovent certified ❯❯Easy maintenance WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Leaving water temperature (sans glycol) Leaving water temperature (avec glycol max 40%) External Max air temperature External Min air temperature 5 / 20°C -12 / 5°C 45°C -10°C Heating mode Leaving water temperature max External Max air temperature External Min air temperature 55°C 20°C -10°C 52 Code 79 83 101 118 119 150 170 171 180 183 251 350 449 450 459 720 721 722 723 725 726 727 728 923 926 931 934 943 Electrical panel heating system Compressor operation indicator EC Fan Brine version kit A Brine version kit B LNO Kit Spring antivibration holders Rubber antivibration holders Power factor capacitor for motor compressor Complete hydraulic connection Coils protection nets Kit TK PRO KIT protective coating for hard environnement Voltage free contact for partial heat recovery water pump activation Desuperheater Shell and tube evaporator Average discharge head single pump Average discharge head double pump Low discharge head single pump Low discharge head double pump Water tank + 1 pump medium pressure Water tank + 2 pump medium pressure Water tank + 1 pump low pressure Water tank + 2 pump low pressure COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board MP.COM expansion card Data Logger preliminary data EQPH MODEL 128,1 128,2 146,1 146,2 164,1 164,2 186,1 COOLING CAPACITY kW 117 117 138 138 155 155 175 Compressors power input kW 42,6 42,6 46,3 46,3 52,3 52,3 60,1 72,6 72,6 79,6 79,6 89,5 89,6 102 12 12 12 12 12 12 12 7 7 7 7 7 7 7 20,1 20,1 23,7 23,7 26,7 26,7 30,1 45 41 50 55 47 51 49 35 35 35 35 35 35 35 HEATING CAPACITY kW 132 132 153 153 173 177 197 Compressors power input kW 41,1 41 47,8 47,7 53,6 53,2 61,2 70,8 70,8 81,7 81,7 91,6 90,8 104 39,3 39,3 39,4 39,4 39,4 39,2 39,3 45 45 45 45 45 45 45 SUMMER WORKING MODE Compressors electric absorption A Water temperature (in) °C Water temperature (out) °C Water flow m³/h Pressure drop kPa External air temperature °C WINTER WORKING MODE Compressors electric absorption A Water temperature (in) °C Water temperature (out) °C External air temperature °C COMPRESSORS Quantity n. Max electric absorption [FLA] A Starting current [LRA] A 7 7 7 7 7 7 7 scroll scroll scroll scroll scroll scroll scroll 2 2 2 2 2 2 2 97 97 114 113,9 97 131 148 473 321 320,5 359 358,5 321 320,5 Capacity steps n. 2 2 2 2 2 2 2 n. 1 1 1 1 1 1 1 8 8,8 9 8,8 11 8,6 12 28,1 28,1 33,1 33,1 37,3 37,4 42,1 0 0 0 0 0 0 0 0,043 0,043 0,043 0,043 0,043 0,043 2 2 3 3 3 3 3 36900 36900 56700 56700 56700 56700 55350 2,8 2,8 4,3 4,3 4,3 4,3 4,3 7,8 7,8 11,7 11,7 11,7 11,7 11,7 R410A R410A R410A R410A R410A R410A R410A 44,6 47,7 52,1 55,7 53 56,7 65,6 1 2 1 2 1 2 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 PLANT WATER EXCHANGER Water content l Maximum water flow m³/h Antifreezing % Fouling factor m²°K/kW 0,043 AXIAL FANS n. Air flow m³/h Engaged power kW Max electric absorption [FLA] A REFRIGERANT Total refrigerant charge kg Gas Circuits n. POWER SUPPLY V/ph/Hz ENERGY EFFICIENCY INDEXES EER Eurovent kW/kW 2,53 2,53 2,67 2,67 2,69 2,69 2,67 EER = Energy Efficiency Ratio kW/kW 2,58 2,58 2,73 2,73 2,74 2,74 2,72 COP Eurovent kW/kW 2,98 2,99 2,91 2,91 2,96 3,05 2,98 COP = Coefficient of Performance kW/kW 3,01 3,01 2,94 2,94 2,99 3,08 3,01 3,41 3,42 3,61 3,62 3,64 3,65 3,61 SPL @ 1 m in free field conditions (ISO3744) dB(A) 63,9 63,8 64,1 64,1 64,1 64,1 66,1 Power level Lw (ISO EN 9614-2) dB(A) 81,9 81,9 83 83 83 83 85 Length mm 2960 2960 4000 4000 4000 4000 4000 Width mm 1200 1200 1200 1200 1200 1200 1200 ESEER = Eurovent Standard IPLV = ARI Standard 550/590 Sound Level DIMENSIONS NET WEIGHT Height mm 1950 1950 1970 1970 1970 1970 1970 kg 1065 1097 1160 1194 1182 1217 1277 ➜ 53 Heat pump - EQPH 128 / 830 | preliminary data EQPH MODEL 186,2 204,1 204,2 215,2 235,2 255,2 305,2 COOLING CAPACITY kW 175 194 195 194 210 242 274 Compressors power input kW 60,2 68,6 68,6 66,9 76,9 81,1 96,7 SUMMER WORKING MODE Compressors electric absorption A Water temperature (in) °C Water temperature (out) °C 102 115 116 120 132 140 165 12 12 12 12 12 12 12 7 7 7 7 7 7 7 30,1 33,4 33,5 33,4 36,2 41,5 47 48 47 46 47 46 51 43 35 35 35 35 35 35 35 HEATING CAPACITY kW 201 218 222 220 240 281 315 Compressors power input kW 60,8 68,7 68,2 67 74,5 83,4 94,9 103 116 115 120 129 143 162 39,2 39,3 39,2 39,3 39,2 39,1 39,2 Water temperature (out) °C 45 45 45 45 45 45 45 External air temperature °C 7 7 7 7 7 7 7 scroll scroll scroll scroll scroll scroll scroll 2 2 2 4 4 4 4 148 165 165,2 165 177 194 228 Water flow m³/h Pressure drop kPa External air temperature °C WINTER WORKING MODE Compressors electric absorption A Water temperature (in) °C COMPRESSORS Quantity n. Max electric absorption [FLA] A Starting current [LRA] A Capacity steps n. PLANT WATER EXCHANGER n. Water content l Maximum water flow m³/h Antifreezing % 473,4 491 490,6 389 401 418 472 2 2 2 4 4 4 4 1 1 1 1 1 1 1 9,8 14 11,7 11,7 13,3 15,1 22,8 42,1 46,7 46,8 46,7 50,5 58,1 65,7 0 0 0 0 0 0 0 Fouling factor m²°K/kW 0,043 AXIAL FANS n. Air flow m³/h Engaged power kW Max electric absorption [FLA] A REFRIGERANT Total refrigerant charge kg Gas Circuits n. POWER SUPPLY V/ph/Hz 0,043 0,043 0,043 0,043 0,043 0,043 3 3 3 4 4 6 6 55350 55350 55350 68400 68400 106920 106920 4,3 4,3 4,3 5,7 5,7 8,5 8,5 11,7 11,7 11,7 15,6 15,6 23,4 23,4 R410A R410A R410A R410A R410A R410A R410A 70,2 66 70,6 67,2 69,2 76,2 77,4 2 1 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,57 ENERGY EFFICIENCY INDEXES EER Eurovent kW/kW 2,67 2,62 2,63 2,63 2,5 2,66 EER = Energy Efficiency Ratio kW/kW 2,71 2,66 2,67 2,67 2,54 2,7 2,6 COP Eurovent kW/kW 3,06 2,96 3,04 3 2,97 3,04 3,03 COP = Coefficient of Performance kW/kW 3,09 2,99 3,06 3,03 2,99 3,06 3,05 3,61 3,54 3,55 3,59 3,42 3,62 3,49 66,1 67,5 67,5 68,9 70 71,2 71,2 85 86,4 86,4 87,7 88,8 90,7 90,7 ESEER = Eurovent Standard IPLV = ARI Standard 550/590 Sound Level SPL @ 1 m in free field conditions (ISO3744) dB(A) Power level Lw (ISO EN 9614-2) dB(A) DIMENSIONS NET WEIGHT Length mm 4000 4000 4000 2410 2410 3530 3530 Width mm 1200 1200 1200 2260 2260 2260 2260 Height mm 1970 1970 1970 2304 2304 2304 2304 kg 1316 1296 1335 1957 2114 2458 2507 54 340,2 380,2 410,2 430,3 470,3 500,3 560,3 610,3 680,4 750,4 800,4 830,4 306 340 380 408 430 469 506 542 615 666 729 772 108 127 142 145 147 165 190 221 217 254 265 274 184 213 238 247 251 279 320 369 368 427 445 461 12 12 12 12 12 12 12 12 12 12 12 12 7 7 7 7 7 7 7 7 7 7 7 7 52,7 58,5 65,4 70,3 74 80,8 87,1 92,9 106 114 126 133 45 43 46 31 34 40 44 50 59 70 80 57 35 35 35 35 35 35 35 35 35 35 35 35 359 402 456 482 512 558 617 678 728 823 873 932 104 122 137 142 148 163 179 201 213 238 258 274 178 206 230 243 253 278 304 339 364 404 436 461 39,1 39 38,9 39 39 39 38,8 38,7 39 38,7 39 38,9 45 45 45 45 45 45 45 45 45 45 45 45 7 7 7 7 7 7 7 7 7 7 7 7 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 4 4 4 6 6 6 6 6 8 8 8 8 262 296 330 342 359 393 444 496 523 592 626,4 660,8 506 621 656 586 603 718 769 821 866 917 951,8 986,2 4 4 4 6 6 6 6 6 8 8 8 8 1 1 1 1 1 1 1 1 1 1 1 1 22,8 26 29,2 133,4 124,7 124,7 221,7 221,7 221,7 206,5 184,4 184,4 73,6 81,7 91,4 107 110 110 135 135 135 160 190 190 0 0 0 0 0 0 0 0 0 0 0 0 0,043 0,043 0,043 0,043 0,043 0,043 0,043 0,043 0,043 0,043 0,043 0,043 6 6 8 9 9 9 9 9 12 12 14 16 102600 102600 142560 160380 153900 153900 153900 153900 205200 205200 239400 273600 8,5 8,5 11,4 12,8 12,8 12,8 12,8 12,8 17,1 17,1 19,9 22,8 23,4 23,4 31,2 35,1 35,1 35,1 35,1 35,1 46,8 46,8 54,6 62,4 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 100,9 101,9 102,9 141,9 162,5 164 182,5 182,5 233,3 237,8 269,4 294,8 2 2 2 3 3 3 3 3 4 4 4 4 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,59 2,48 2,45 2,56 2,66 2,61 2,47 2,29 2,59 2,42 2,51 2,56 3,17 3,06 3,05 3,1 3,17 3,16 3,2 3,15 3,14 3,2 3,11 3,12 3,52 3,37 3,33 3,48 3,62 3,55 3,36 3,11 3,53 3,3 3,44 3,5 71,2 73,6 75,1 72,9 72,9 74,3 75,3 76,8 74,2 76,6 77,4 78,1 90,7 93 95,1 93,4 93,4 94,8 95,8 97,3 95,1 97,5 98,8 99,8 3530 3530 4650 5770 5770 5770 5770 5770 6890 6890 8010 9130 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2304 2304 2304 2304 2304 2304 2304 2304 2304 2304 2304 2304 2681 2739 3015 3876 4029 4087 4422 4461 5213 5358 5600 5789 55 Air Cooled Chiller | EQUH 21 / 260 Heat pump Scroll R410A ooling Capacity from 20 to 260 KW C Heating capacity from 23 to 333 KW Size = 29 Refrigerant : R410A EER up to 3,08 ESSEER up to 4,67 COP up to 3,66 Main Functions: eat pump operation H Available with one or 2 cooling circuit 1 or 2 scroll compressors following sizes Condenser coil on only one face Implementation for difficult place Main accessories and options Available Versions: artial heat recovery P Extra low noise For available air static pressure see PF version next page Product Advantages Implantation angles or against wall Choice mono or bi-circuit Water tank under the unit for a better mass repartition and low footprint (option) Easy acces to component High performances Choice of the sound level Total or partial heat recovery Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance Service valves on gas discharge and liquid line WORKING LIMITS - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. Hot water outlet temperature ••• •••••• • • • •••• •••• •••• •••• •••• •••• ••• • •••••••••••••••••••••••••• ••• ••••• •••••••••••••••••••• • ••••••••••••••••••••••••• ••• ••••••••••••••••••••• ••• • •••••••••••• •••••••••••• • • •••••••••••• • ••••••••••••••••••• •••••••••••••••••• • • ••••••••••• • •••••••••••••••• ••• ••••• •• Ambiant air temperature 56 Code 150 151 170 172 175 251 351 450 605 731 739 740 756 757 768 919 923 926 931 932 934 942 943 LNO Kit Kit ELN Spring antivibration holders Rubber support (kit) Victaulic Connections Coils protection nets Kit Coils with pre painted fins Desuperheater Compr. Power factor capcitor 0,9 Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group LN 1 pump Pumping group LN 2 pumps Chilled water storage tank Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQUH MODEL 21.1 24.1 28.1 30.1 34.1 19,2 6,1 11,1 3,3 26 21,6 7,1 13,2 3,7 33 25,5 8,2 15,2 4,4 36 27,7 10,2 18,2 4,8 27 32,7 10,1 18,5 5,6 35 23,9 6,2 11,2 27,2 7,1 13,3 31,8 8,2 15,2 32,1 9,4 16,7 41 10,3 19 7 1,2 17,5 7,9 1,4 22,2 9,4 1,6 30,9 10,2 1,8 12,3 12 2,1 17,1 SUMMER WORKING MODE (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Plant exchanger water flow rate Plant exchanger pressure drop kW kW A m³/h kPa WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Total air flow m³/h Power input kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER - Energy Efficiency Ratio kW/kW COP - Coefficient of Performance kW/kW ESEER Eurovent Standard IPLV - ARI Standard 550/590 scroll scroll scroll scroll scroll 1 16 95 1 1 21 111 1 1 22 118 1 1 25 118 1 1 31 140 1 1 1 1 1 1 1,9 4,9 1,9 5,6 1,9 6,6 2,5 7,1 2,5 7,8 1 1 1 1 1 0,4 1,8 0,4 2,1 0,4 2,4 0,6 2,6 0,6 2,9 1 1 1 1 2 8500 0,5 1,6 8500 0,5 1,6 11000 0,8 1,6 11000 0,8 1,6 13000 0,5 3,2 R410A R410A R410A R410A R410A 10,5 1 10,6 1 10,6 1 10,8 1 12,9 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,95 3,6 4,59 5,09 2,87 3,59 4,66 5,17 2,86 3,57 4,48 4,97 2,53 3,17 4,29 4,76 3,08 3,8 4,67 5,18 64,6 81,1 64,9 81,5 65,6 82,2 64,8 81,4 64,9 82,2 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 2/1 -2/1 LN -210 1250 890 2010 1250 890 2010 1250 890 2010 1250 890 2010 1800 1040 2060 390 390 400 410 410 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 2" -- 1" 1" 1" 1" 1 1/4" SOUND LEVEL - ISO 3744 Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF REV PPF REV PPF REV PPF REV l DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg PLANT WATER EXCHANGER Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to hot water outlet temperature at 45°C; 7°C ambient temperature. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 57 ➜ Heat pump - EQUH 21 / 260 | EQUH MODEL 40.1 50.1 52.1 52.2 37,6 12,2 23,6 6,5 36 46,8 15,7 27,6 8,1 31 47,7 16,8 31,3 8,2 32 47,7 16,8 31,3 8,2 32 47,2 12,2 23,6 60 15,9 25,6 61,7 17 31,8 61,5 16,6 30,8 13,8 2,4 22,6 17,2 3 35 17,5 3 23,7 17,5 3 27,1 SUMMER WORKING MODE (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Plant exchanger water flow rate Plant exchanger pressure drop kW kW A m³/h kPa WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. scroll scroll scroll scroll 1 34 174 1 1 40 225 1 1 44 140 1 2 44 140 2 1 1 1 1 2,5 9 3,1 11,2 3,9 11,4 3,6 11,3 1 1 1 1 0,6 3,3 0,6 4,1 0,8 4,2 0,7 4,8 2 2 2 2 15000 0,8 3,2 20500 1,6 3,3 20500 1,6 3,3 20500 1,6 3,3 R410A R410A R410A R410A 12,9 1 14,3 1 18,1 1 14,6 2 400/3/50 400/3/50 400/3/50 400/3/50 2,9 3,64 4,29 4,76 2,7 3,42 3,83 4,25 2,59 3,31 4,2 4,66 2,59 3,38 3,6 3,99 67,7 84,9 71,8 89 68,9 86,1 68,9 86,1 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 1800 1040 2060 1800 1040 2060 1800 1040 2060 1800 1040 2060 420 650 650 650 Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet - OD Ø mm 2" -- 2" -- 2" -- 2" -- Inlet / Outlet (ISO 7/1 - R) Ø 1 1/4" 1 1/4" 1 1/4" 1 1/4" Total air flow m³/h Power input kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW COP - Coefficient of Performance kW/kW ESEER Eurovent Standard IPLV - ARI Standard 550/590 SOUND LEVEL - ISO 3744 Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF REV PPF REV PPF REV PPF REV l DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg HYDRAULIC CONNECTIONS PLANT WATER EXCHANGER PARTIAL HEAT RECOVERY 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to hot water outlet temperature at 45°C; 7°C ambient temperature. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 58 58.1 58.2 62.1 65.1 65.2 76.1 76.2 98.1 54,3 17,9 32,1 9,3 32 54,6 18,9 33,9 9,4 17 58 19,9 34,6 10 27 60,6 20,5 37,6 10,4 32 61,3 20,7 37,9 10,5 18 70,3 24,4 47,3 12,1 33 71,4 24,4 47,3 12,3 20 89,6 30,8 54,4 15,4 32 70,7 18,2 32,6 70,9 18,5 35 74,8 20 35,1 79,1 20,5 37,8 79,2 20,9 38,3 91,6 24,3 47,4 90,8 24,6 47,6 118 31,8 56,2 19,9 3,4 30,7 20 3,5 11,9 21,3 3,7 35 22,2 3,8 38,2 22,5 3,9 15 25,8 4,4 30,1 26,2 4,5 20,3 32,9 5,7 28,5 scroll scroll scroll scroll scroll scroll scroll scroll 2 50 143 2 2 50 143 2 2 48,5 272 2 2 62 171 2 2 62 171 2 2 68 208 2 2 68 208 2 2 80 265 2 1 1 1 1 1 1 1 1 3,9 13 3,6 13 3,9 13,9 4,7 14,6 4,2 14,5 5,8 17,4 5,1 16,9 5,8 22 2 1 2 1 2 1 2 1 0,8 4,8 1,1 5,1 0,8 4,2 0,8 5,4 1,2 5,3 1 6,4 1,2 6,2 1,7 8,1 3 3 3 3 3 3 3 4 22000 1,1 4,7 22000 1,1 4,7 23000 1,3 4,7 24000 1,5 4,7 24000 1,5 4,7 30000 2,4 4,9 30000 2,4 4,9 40000 2,5 6,5 R410A R410A R410A R410A R410A R410A R410A R410A 19,6 1 17,9 2 22,9 1 18,3 1 23,3 2 21,6 1 24 2 32,3 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,85 3,66 4,11 4,56 2,73 3,61 4,02 4,46 2,74 3,51 4,32 4,79 2,76 3,6 3,84 4,26 2,76 3,54 4,3 4,77 2,63 3,43 4,01 4,45 2,67 3,37 3,52 3,9 2,69 3,44 4,18 4,63 68 85,9 68 85,9 73,8 91,6 67,8 85,7 67,8 85,7 68,2 86,1 68,2 86,1 65,6 84,2 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 4/1 4/2 4/1 LN 4/2 LN 520 2600 1200 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 2600 1200 2060 3700 1260 2050 720 730 700 730 730 920 930 1120 -76,1 -76,1 -76,1 -76,1 -76,1 -76,1 -76,1 -88,9 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" ➜ 59 Heat pump - EQUH 21 / 260 | EQUH MODEL 98.2 124.1 124.2 158.1 91,8 31 55 15,8 23 111 39 68,1 19,2 34 116 39,5 69 19,9 27 150 52,5 89,8 25,8 32 118 31,9 56,2 149 40,6 70,2 150 40,3 69,9 182 61,3 86,2 33,7 5,8 33,7 40,9 7 30,8 42,5 7,3 34,9 55,1 9,5 42,9 SUMMER WORKING MODE (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Plant exchanger water flow rate Plant exchanger pressure drop kW kW A m³/h kPa WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. scroll scroll scroll scroll 2 80 265 2 2 97 320,5 2 2 97 320,5 2 2 130,8 375,4 2 1 1 1 1 6,7 21,5 7,2 27,7 6,7 26,7 8,7 37,9 2 1 2 1 1,2 7,9 2,1 10,2 1,5 9,8 4 13,9 4 4 4 4 40000 2,5 6,5 46000 3,6 11,4 46000 3,6 11,4 55800 6,4 11,4 R410A R410A R410A R410A 35,4 2 36,7 1 39,8 2 37,7 1 400/3/50 400/3/50 400/3/50 400/3/50 2,74 3,43 3,71 4,11 2,61 3,37 4,01 4,45 2,69 3,42 3,55 3,94 2,55 2,69 3,75 4,16 65,6 84,2 69,5 88,1 69,5 88,1 72 90,6 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 Length mm Width mm Height mm 3700 1260 2050 3700 1260 2050 3700 1260 2050 3700 1260 2050 kg 1120 1510 1500 1600 Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet - OD Ø mm -88,9 -88,9 -88,9 -88,9 Inlet / Outlet (ISO 7/1 - R) Ø 2" 2" 2" 2" Total air flow m³/h Power input kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW COP - Coefficient of Performance kW/kW ESEER Eurovent Standard IPLV - ARI Standard 550/590 SOUND LEVEL - ISO 3744 Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF REV PPF REV PPF REV PPF REV l DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS PLANT WATER EXCHANGER PARTIAL HEAT RECOVERY 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to hot water outlet temperature at 45°C; 7°C ambient temperature. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 60 158.2 180.1 180.2 197.1 197.2 230.1 240.2 260.2 155 53,1 91 26,6 26 170 58,4 100 29,1 34 176 59,3 102 30,3 33 188 66,1 114 32,4 41 194 66,8 115 33,4 32 227 79,7 136 39 41 223 85,2 146 38,4 36 261 100 170 45 33 195 41,3 71,4 215 57,3 98,9 215 57,4 99,4 238 64 110 238 64,5 112 280 75,4 130 288 80,8 141 333 90,1 156 56,9 9,8 36,1 62,2 10,7 32,1 64,8 11,2 27,7 69,1 11,9 39,6 71,2 12,3 33,5 83,2 14,3 40,9 81,9 14,1 30,6 95,8 16,5 41,9 scroll scroll scroll scroll scroll scroll scroll scroll 2 130,8 375,4 2 2 147,4 439,4 2 2 147,4 439,4 2 2 164 456 2 2 164 456 2 3 196,2 440,8 3 4 194 417,5 4 4 294,8 586,8 4 1 1 1 1 1 1 1 1 8,3 37,7 11,1 42,2 9,5 40,6 17,6 48,3 15,8 46,9 17,6 55,3 20,3 54,5 20,3 60,6 2 1 2 1 2 1 2 2 2 13,8 5,3 15,5 3,4 14,9 5,3 17,7 3,4 17,2 6,3 20,3 4,2 20 4,2 22,2 4 5 5 5 5 5 5 5 55800 6,4 11,4 60000 4,6 14,3 60000 4,6 14,3 66000 6,1 14,3 66000 6,1 14,3 69000 7 14,3 69000 8,1 14,3 69000 8,1 14,3 R410A R410A R410A R410A R410A R410A R410A R410A 40,4 2 60,6 1 63,7 2 78,8 1 95,6 2 79,5 1 106,8 2 106,7 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,6 4,09 3,45 3,83 2,7 3,48 4,17 4,62 2,76 3,47 3,65 4,05 2,6 3,4 4,1 4,55 2,66 3,37 3,63 4,03 2,62 3,4 4,27 4,73 2,39 3,24 3,35 3,72 2,42 3,39 3,3 3,66 72 90,6 69,3 88,6 69,3 88,6 71,1 90,4 71,1 90,4 71,9 91,2 73,6 92,9 73,8 93 4/1 4/2 4/1 LN 4/2 LN 520 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 3700 1260 2050 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 4950 1260 2090 1590 1650 1640 2050 2040 2220 2380 2430 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 2" 2" 2" 2" 2" 2" 2" 2" 61 Aircooled Chiller | EQUH PF 22 / 290 Heat pump Scroll Ductable R410A ooling Capacity from 20 to 260 KW C Heating capacity from 23 to 333 KW Size = 29 Refrigerant : R410A EER up to 3,08 ESSEER up to 4,67 COP up to 3,66 Main Functions: eat pump operation H Available with one or 2 cooling circuit 1 or 2 scroll compressors following sizes Condenser coil on only one face Implementation for difficult place Ductable unit with 50 to 700 Pa available static pressure (following models) Main accessories and options Available Versions: artial heat recovery P Extra low noise Product Advantages entilateurs plug fan as std V Implantation angles or against wall Choice mono or bi-circuit Water tank under the unit for a better mass repartition and low footprint (option) Easy acces to component High performances Choice of the sound level Total or partial heat recovery Standard EC fan motor remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance Service valves on gas discharge and liquid line WORKING LIMITS - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. Hot water outlet temperature ••• •••••• • • • •••• •••• •••• •••• •••• •••• ••• • •••••••••••••••••••••••••• ••• ••••• •••••••••••••••••••• • ••••••••••••••••••••••••• ••• ••••••••••••••••••••• ••• • •••••••••••• •••••••••••• • • •••••••••••• • ••••••••••••••••••• •••••••••••••••••• • • ••••••••••• • •••••••••••••••• ••• ••••• •• Ambiant air temperature 62 Code 150 160 170 172 175 251 351 450 460 605 731 739 740 756 757 768 919 923 926 931 932 934 942 943 LNO Kit Discharge air plenum with sound attenuator Spring antivibration holders Rubber support (kit) Victaulic Connections Coils protection nets Kit Coils with pre painted fins Desuperheater Kit for Outdoor installation Compr. Power factor capcitor 0,9 Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group LN 1 pump Pumping group LN 2 pumps Chilled water storage tank Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQUH PF MODEL 22.1 24.1 28.1 32.1 36.1 42.1 53.1 19,1 6,4 11,5 3,3 27 20,7 7,4 13,7 3,6 35 24,2 8,7 16 4,2 37 28,8 9,9 17,4 5 29 32 11 19,9 5,5 35 36,5 13,4 25,3 6,3 36 46,2 16,6 28,7 7,9 32 23,7 6,2 11,3 25,1 7 13,3 29,3 8,1 15,2 35,5 9,3 16,5 39,8 10,3 18,8 45,6 12,1 23,4 58,2 16,1 28,2 7 1,2 17,3 7,6 1,3 20,3 8,9 1,5 27,9 10,6 1,8 13,2 11,8 2 16,4 13,4 2,3 21,3 17 2,9 34,1 SUMMER WORKING MODE (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop kW kW A m³/h kPa WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PLUG FANS Total air flow External static pressure Max external static pressure Engaged power Plate current [FLA] scroll scroll scroll scroll scroll scroll scroll 1 16 95 1 1 21 111 1 1 22 118 1 1 25 118 1 1 31 140 1 1 34 174 1 1 40 225 1 1 1 1 1 1 1 1 1,9 6,9 1,9 7,8 2,1 9 2,8 10,3 2,9 11,6 3,3 13,4 4,2 16,9 1 1 1 1 1 1 1 0,4 1,9 0,4 2,1 0,4 2,4 0,6 2,8 0,6 3,1 0,6 3,6 0,6 4,6 n. 1 1 1 1 1 1 2 m³/h Pa Pa kW A 6500 50 737 0,6 4,3 7000 50 704 0,7 4,3 8500 50 509 1,1 4,3 10000 50 480 1,2 4,9 11000 50 312 1,6 4,9 12000 50 112 2,1 4,9 16000 50 568 2 8,6 REFRIGERANT R410A R410A R410A R410A R410A R410A R410A 10,5 1 10,6 1 10,6 1 10,8 1 10,8 1 10,8 1 14,3 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,74 3,51 4,49 4,98 2,56 3,26 4,4 4,88 2,46 3,16 4,05 4,5 2,6 3,38 4,1 4,55 2,54 3,34 3,88 4,3 2,36 3,22 3,57 3,96 2,48 3,21 3,93 4,36 Average sound pressure level [LPm] (4) dB(A) 70,6 72,1 76,3 75,6 77,6 79,4 77,6 Sound power level [Lw] (5) dB(A) 87,1 88,7 92,9 92,1 94,2 96 94,8 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 1/1 -1/1 LN -130 2/1 -2/1 LN -210 1250 890 1950 1250 890 1950 1250 890 1950 1250 890 1950 1250 890 1950 1250 890 1950 1800 1040 2000 390 390 400 410 410 420 650 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 1 1/2" -- 2" -- 1" 3/4" 1" 3/4" 1" 3/4" 1" 3/4" 1" 3/4" 1" 3/4" 1 1/4" 3/4" Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES (1) V/Ph/Hz EER - Energy Efficiency Ratio kW/kW COP - Coefficient of Performance kW/kW ESEER Eurovent Standard IPLV - ARI Standard 550/590 SOUND LEVEL - ISO 3744 PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF REV 1/1 PPF REV -PPF REV 1/1 LN PPF REV -l 130 DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg PLANT SIDE HEAT E Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD (6) Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø Condensate discharge (iso 7/1 - r) Ø 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to hot water outlet temperature at 45°C; 7°C ambient temperature. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 63 4. Sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 – 2. ➜ Heat pump - EQUH PF 22 / 290 | EQUH PF MODEL 67.1 55.1 55.2 62.1 62.2 71.1 71.2 85.1 58,4 21,1 36,1 10 29 48,7 17,1 31,6 8,4 36 48,4 17,1 31,4 8,3 21 54,8 19,6 34,7 9,4 35 54,8 19,6 34,7 9,4 18 62 21,8 39,5 10,7 34 61,5 21,8 39,3 10,5 20 72,8 25,4 48,4 12,5 37 73,1 20 34,7 61,5 16,9 31,2 62 16,7 30,9 69,5 19,1 34 69,3 18,7 33,5 77,7 20,8 38,1 77,4 20,6 37,7 85,7 24,4 47,2 21,4 3,7 35,5 17,9 3,1 24,7 17,7 3,1 27,8 20,1 3,5 31,2 20,1 3,5 12 22,8 3,9 40 22,6 3,9 15,1 26,7 4,6 32,3 SUMMER WORKING MODE (1) COOLING CAPACITY Compressors power input Compressors operating current [OA] Evaporator water flow rate Evaporator pressure drop kW kW A m³/h kPa WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h PLUG FANS Total air flow External static pressure Max external static pressure Engaged power Plate current [FLA] scroll scroll scroll scroll scroll scroll scroll 2 44 140 2 2 44 140 2 2 50 143 2 2 50 143 2 2 62 171 2 2 62 171 2 2 68 208 2 1 1 1 1 1 1 1 1 5,7 21,4 4,2 17,6 4,3 17,6 4,8 19,9 5,3 20 5,5 22,7 5,6 22,7 6,3 27 1 1 2 1 2 1 2 1 0,8 5,8 0,8 4,8 0,7 4,8 0,8 5,4 1,1 5,4 0,8 6,2 1,2 6,2 1 7,3 n. 2 2 2 2 2 2 2 3 m³/h Pa Pa kW A 21000 50 363 2,3 8,4 18000 50 589 2 9,8 18000 50 589 2 9,8 20500 50 421 2,2 8,4 20500 50 421 2,2 8,4 23000 50 308 2,9 8,4 23000 50 308 2,9 8,4 25500 50 643 2,7 14,7 REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY scroll 1 48,5 272 1 V/Ph/Hz R410A R410A R410A R410A R410A R410A R410A R410A 14,8 1 14,6 1 19,6 2 14,5 1 19,6 2 15 1 19,9 2 21,6 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFICIENCY INDEXES (1) EER - Energy Efficiency Ratio kW/kW COP - Coefficient of Performance kW/kW ESEER Eurovent Standard IPLV - ARI Standard 550/590 2,5 3,28 3,56 4,02 2,55 3,25 3,92 4,35 2,53 3,31 4,31 4,78 2,52 3,27 3,93 4,36 2,52 3,32 3,73 4,14 2,51 3,28 4,04 4,48 2,49 3,29 3,71 4,11 2,59 3,17 4,41 4,89 79,5 96,7 75,9 93,1 75,9 93,1 69,6 86,8 69,6 86,8 72 89,2 72 89,2 76 93,9 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 2/1 -2/1 LN -210 3/1 3/2 3/1 LN 3/2 LN 360 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 1800 1040 2000 2600 1200 2000 700 650 650 720 730 730 740 920 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- -76,1 1 1/4" 3/4" 1 1/4" 3/4" 1 1/4" 3/4" 1 1/4" 3/4" 1 1/4" 3/4" 1 1/4" 3/4" 1 1/4" 3/4" 1 1/2" 2 x 3/4" SOUND LEVEL - ISO 3744 Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP With 1 pump – 2 poles motor With 2 pumps – 2 poles motor With 1 pump – 4 poles motor With 2 pumps – 4 poles motor WATER TANK - Volume PPF REV 2/1 PPF REV -PPF REV 2/1 LN PPF REV -l 210 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg HYDRAULIC CONNECTIONS PLANT SIDE HEAT E Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD (6) Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø Condensate discharge (iso 7/1 - r) Ø 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to hot water outlet temperature at 45°C; 7°C ambient temperature. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 64 4. Sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 – 2. 85.2 107.1 107.2 135.1 135.2 170.1 170.2 195.1 195.2 220.1 220.2 250.1 265.2 290.2 71,9 25,3 48,4 12,4 23 93,1 32,6 56,8 16 35 91 32,3 56,2 15,7 26 115 41,9 71,6 19,8 36 112 41,7 71,3 19,3 30 150 52,9 90,3 25,8 35 146 52,6 89,9 25,1 33 175 63,1 107 30,2 41 170 62,3 106 29,3 35 201 68 116 34,6 42 195 67,4 115 33,6 36 230 84,7 143 39,6 40 231 85,4 145 39,8 41 255 102 173 44 44 92,4 24,4 47,1 117 32 56,2 117 31,6 55,7 147 40,4 69,9 147 40,1 69,6 189 51,4 88,5 189 51,4 88,3 211 57,6 99,8 198 56,7 98,1 241 64,2 111 241 63,7 110 273 75,9 131 291 79,4 138 324 90,7 157 26,4 4,6 20,7 34,2 5,9 30,8 33,4 5,8 33,1 42,3 7,3 32,8 41,1 7,1 32,7 55 9,5 42,6 53,5 9,2 31,9 64,4 11,1 34,4 62,5 10,8 25,8 73,9 12,7 45,3 71,7 12,4 34 84,5 14,6 42,2 84,9 14,6 32,9 93,6 16,1 40 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 2 68 208 2 2 80 265 2 2 80 265 2 2 97 320,5 2 2 97 320,5 2 2 130,8 375,4 2 2 130,8 375,4 2 2 147,4 439,4 2 2 147,4 439,4 2 2 164 456 2 2 164 456 2 3 196,2 440,8 3 4 194 417,5 4 4 294,8 586,8 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5,9 27 8,4 34,1 7,5 33,8 10,5 42,4 8,8 41,9 14,7 55 11,4 54,2 14 60,9 17,2 61,9 16 70 19,6 71,1 18,8 79,6 22 84,6 23,6 92,6 2 1 2 1 2 1 2 1 2 1 2 1 2 2 1,2 7,3 1,7 9,3 1,2 9,2 2,1 11,5 1,5 11,4 4 14,9 2 14,7 5,3 16,5 3,4 16,8 5,3 19 3,4 19,3 6,3 21,6 4,2 23 4,2 25,1 3 3 3 4 4 4 4 4 4 5 5 5 5 5 25500 50 643 2,7 14,7 32000 50 324 5 14,7 32000 50 324 5 14,7 40000 50 467 3,6 16,8 40000 50 467 3,6 16,8 52000 50 175 7,6 16,8 52000 50 175 7,6 16,8 54000 50 120 8,5 16,8 54000 50 120 8,5 16,8 62500 50 243 8,2 21 62500 50 243 8,2 21 64000 50 212 8,8 21 66000 50 147 10,1 21 66000 50 147 10,1 21 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 24 2 30,1 1 33,1 2 33,2 1 36,4 2 37,7 1 40,4 2 38,8 1 41,8 2 78,8 1 95,6 2 79,5 1 106,8 2 106,7 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,57 3,41 3,95 4,38 2,48 3,17 3,89 4,31 2,44 3,2 3,56 3,95 2,53 3,34 4,45 4,93 2,47 3,36 3,94 4,37 2,48 3,2 3,91 4,33 2,42 3,2 3,58 3,97 2,45 3,19 3,79 4,2 2,4 3,04 3,49 3,87 2,64 3,33 4,13 4,58 2,58 3,35 3,81 4,23 2,46 3,22 4,31 4,78 2,42 3,25 3,68 4,08 2,27 3,21 3,55 3,94 76 93,9 80,8 98,7 80,8 98,7 74 92,6 74 92,6 77,3 95,9 77,3 95,9 78 96,6 78 96,6 77,3 96,6 77,3 96,6 77,7 96,9 78,1 97,4 78,1 97,4 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 3/1 3/2 3/1 LN 3/2 LN 360 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 4/1 4/2 4/1 LN 4/2 LN 520 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 5/1 5/2 5/1 LN 5/2 LN 720 2600 1200 2000 2600 1200 2000 2600 1200 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 3700 1260 2000 4950 1260 2040 4950 1260 2040 4950 1260 2040 4950 1260 2040 4950 1260 2040 930 1120 1120 1510 1500 1600 1590 1650 1640 2050 2040 2220 2380 2430 -76,1 -76,1 -76,1 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 1 1/2" 2 x 3/4" 1 1/2" 2 x 3/4" 1 1/2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 2" 2 x 3/4" 65 Air Cooled Chiller | EQSH 200 / 1090 Heat pump Screw ❯❯Cooling Capacity from 201 to 1098 KW ❯❯Heating capacity de 233 à 1307 KW ❯❯Size = 15 ❯❯Refrigerant : R410A ❯❯EER up to 3,02 ❯❯ESSEER up to 3,46 ❯❯COP up to 3,75 Main Functions: ❯❯available with 2 cooling circuits ❯❯2 SCREW compressors mounted on rubber pad ❯❯Leaving hot water Temperature up to 60°C ❯❯Shell and tube evaporator Main accessories and options Available Versions: ❯❯Partial heat recovery ❯❯Extra low noise Product Advantages ❯❯Large cooling capacity range with SCREW technology with a maximum reliability ❯❯Screw compressors per circuit for a highest efficiency and reliability ❯❯Electronic Expansion valve STD ❯❯Linear step capacity control ❯❯Screen display with graphics symbols for an easy reading ❯❯Choice of the sound level ❯❯Total or partial heat recovery ❯❯Remote demand limit via additional elec board ❯❯Analog set point compensation ❯❯Eurovent certified ❯❯Easy maintenance WORKING LIMITS - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. ••• ••••• • • • Hot water outlet temperature •••• •••• •••• •••• •••• •••• •••• •••• ••• ••• • •••••••••••••••••••••••••••••••••• ••• ••••••••••••••••••••••••••••••••••••• ••• ••••••••••••••••••••••••••••••••• •••• • ••••••••••••••••••••••••••• •••••••••• • • •••••••••••••••••••••••••••••••• ••• • •••••••••••••••••••••••••••••• •••••• • • •••• ••• ••••• •• Ambiant air temperature 66 Code 150 151 170 172 175 351 450 452 550 605 650 731 739 740 756 757 919 923 926 931 932 934 942 943 LNO Kit Kit ELN Spring antivibration holders Rubber support (kit) Coils with pre painted fins Desuperheater 20% Sanitary hot water Stop valve on compressor suction line Compr. Power factor capcitor 0,9 Compressor thermal relays Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group LN 1 pump Pumping group LN 2 pumps Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger Data logger EQSH MODEL 200 250 280 340 370 COOLING CAPACITY kW 201 244 281 340 373 Compressors power input kW 59,5 70,3 83,1 99 109 97,3 113 142 142 191 34,5 41,9 48,2 58,4 63,9 10 8 11 9 18 HEATING CAPACITY kW 233 277 321 379 417 Compressors power input kW 65,4 78 92,3 96,4 109 106 124 154 110 167 40 48,5 55,9 67,7 74,1 6,9 8,4 9,6 11,7 12,8 twin-screw twin-screw twin-screw twin-screw twin-screw 2 2 2 2 2 SUMMER WORKING MODE (1) Compressors operating current [OA] A Plant exchanger water flow rate m³/h Plant exchanger pressure drop kPa WINTER WORKING MODE (2) Compressors operating current [OA] A PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h COMPRESSORS Quantity n. Maximum current A 145 165 203 205 236 Starting current A 350 386 474 383 469 Capacity steps 4 4 4 25…100% 25…100% 1 1 1 1 1 20 20 32 225 225 55 70 70 165 165 2 2 2 2 2 18 18 18 18 28 12 12 12 18 18 4 6 6 8 8 Total air flow m³/h 89644 144498 139686 193536 187992 Power input kW 7,7 10,9 11,2 14,6 15 15,6 23,4 23,4 31,2 31,2 R134a R134a R134a R134a R134a 116 103 138 143 191 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 EER - Energy Efficiency Ratio kW/kW 2,99 3 2,98 2,99 3,01 COP - Coefficient of Performance kW/kW 3,19 3,12 3,1 3,41 3,36 3,46 3,42 3,29 3,37 3,38 Average sound pressure level [LPm] (4) dB(A) 72,3 72,2 72,3 71,7 72,1 Sound power level [Lw] (5) dB(A) 91,6 92,2 92,3 92,5 92,9 With 1 pump – 2 poles motor GP R10/1 R20/1 R20/1 R30/1 R30/1 With 2 pumps – 2 poles motor GP R10/2 R20/2 R20/2 R30/2 R30/2 With 1 pump – 4 poles motor GP R10/1 LN R20/1 LN R20/1 LN R30/1 LN R30/1 LN With 2 pumps – 4 poles motor GP R10/2 LN R20/2 LN R20/2 LN R30/2 LN R30/2 LN Length mm 3815 5215 5215 6045 6045 Width mm 2206 2206 2206 2206 2206 Height mm 2015 2015 2015 2525 2525 kg 3181 3773 3783 5714 5730 88,9 88,9 88,9 219,1 219,1 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" PLANT WATER EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES ESEER Eurovent Standard SOUND LEVEL - ISO 3744 PUMPING GROUP DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS PLANT WATER EXCHANGER Inlet / Outlet - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to hot water outlet temperature at 45°C; 7°C ambient temperature. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 67 ➜ Heat pump - EQSH 200 / 1090 | EQSH MODEL 410 440 520 570 COOLING CAPACITY kW 412 448 520 575 Compressors power input kW 123 130 153 169 211 224 253 284 70,7 76,9 89,3 98,9 30 14 32 27 HEATING CAPACITY kW 468 496 599 657 Compressors power input kW 124 125 157 166 186 186 259 280 SUMMER WORKING MODE (1) Compressors operating current [OA] A Plant exchanger water flow rate m³/h Plant exchanger pressure drop kPa WINTER WORKING MODE (2) Compressors operating current [OA] A PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h COMPRESSORS 81,9 89,1 104 114 14,1 15,4 17,8 19,7 twin-screw twin-screw twin-screw twin-screw 2 2 2 2 Maximum current A 270 288 330 367 Starting current A 630 639 811 544 Capacity steps 25…100% 25…100% 25…100% 25…100% Quantity n. PLANT WATER EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h 1 1 1 1 207 310 185 225 165 120 190 148 2 2 2 2 28 36 36 48 38 18 26 26 8 10 10 10 Total air flow m³/h 181216 241920 234990 234990 Power input kW 15,6 18,3 18,8 18,8 31,2 39 39 39 R134a R134a R134a R134a 239 179 238 238 AXIAL FANS n. Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 EER - Energy Efficiency Ratio kW/kW 2,97 3,02 3,03 3,06 COP - Coefficient of Performance kW/kW 3,35 3,46 3,41 3,56 3,31 3,37 3,34 3,45 POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES ESEER Eurovent Standard SOUND LEVEL - ISO 3744 Average sound pressure level [LPm] (4) dB(A) 76,4 76 76,5 76,5 Sound power level [Lw] (5) dB(A) 97,2 97,2 97,7 97,7 With 1 pump – 2 poles motor GP R40/1 R50/1 R50/1 R50/1 With 2 pumps – 2 poles motor GP R40/2 R50/2 R50/2 R50/2 With 1 pump – 4 poles motor GP R40/1 LN R50/1 LN R50/1 LN R50/1 LN With 2 pumps – 4 poles motor GP R40/2 LN R50/2 LN R50/2 LN R50/2 LN Length mm 6045 7175 7175 7175 Width mm 2206 2206 2206 2206 Height mm 2525 2525 2525 2525 kg 5782 6475 6642 6739 219,1 219,1 219,1 219,1 2 x 2" 2 x 2" 2 x 2" 2 x 2" PUMPING GROUP DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS PLANT WATER EXCHANGER Inlet / Outlet - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature. 2. Gross value - Referred to hot water outlet temperature at 45°C; 7°C ambient temperature. 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 68 670 790 880 930 980 1090 668 796 884 937 980 1098 201 242 272 284 298 336 327 372 427 447 479 563 115 137 152 161 168 189 47 41 39 41 44 52 782 945 1030 1092 1160 1307 208 245 261 273 286 321 336 375 412 431 461 540 133 158 176 186 195 219 22,9 27,3 30,3 32,1 33,6 37,6 twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw 2 2 2 2 2 2 414 474 536 567 615 710 568 611 721 827 903 1058 25…100% 25…100% 25…100% 25…100% 25…100% 25…100% 1 1 1 1 1 1 185 225 303 378 378 348 148 165 205 218 218 236 2 2 2 2 2 2 48 58 58 68 76 86 38 52 52 76 96 118 12 12 12 14 14 14 290304 281988 271824 328986 328986 317128 22 22,6 23,4 26,3 26,3 27,3 46,8 46,8 46,8 54,6 54,6 54,6 R134a R134a R134a R134a R134a R134a 214 284 355 331 331 414 2 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3 3,01 2,99 3,02 3,02 3,02 3,4 3,53 3,62 3,65 3,71 3,75 3,38 3,38 3,37 3,41 3,49 3,49 78,8 80,1 79,8 77,7 77,7 80,9 100,4 101,7 101,4 99,9 99,9 102,9 R60/1 R60/1 R70/1 R80/1 R80/1 R80/1 R60/2 R60/2 R70/2 R80/2 R80/2 R80/2 R60/1 LN R60/1 LN R60/1 LN R70/1 LN R70/1 LN R70/1 LN R60/2 LN R60/2 LN R60/2 LN R70/2 LN R70/2 LN R70/2 LN 8305 8305 8305 9435 9435 9435 2206 2206 2206 2206 2206 2206 2525 2525 2525 2525 2525 2525 7118 7695 8170 8507 8567 9563 219,1 219,1 219,1 219,1 219,1 219,1 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 69 Air Cooled Chiller | EQMF 21 / 260 cooling only free cooling Scroll R410A ooling Capacity from 20 to 260 KW C Size = 29 Refrigerant : R410A EER up to 3,02 ESSEER up to 4,67 Main Functions: REE COOLING F Available with one or 2 cooling circuit 1 or 2 scroll compressors following sizes Condenser coil on only one face Implementation for difficult place Main accessories and options Available Versions: artial heat recovery P Extra low noise Brine Low ambiant operation up to -10°C STD For available air static pressure see PF version next page Product Advantages ree cooling = recovery of «free» energy F Implantation angles or against wall Choice mono or bi-circuit Easy acces to component High performances Choice of the sound level Electronic expansion valve from size 98 Remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance Service valves on gas discharge and liquid line Water tank (option) under the unit, optimization for footprint and mass repartition Free cooling coil with 3 way value and ambiant control, management by the unit controller WORKING LIMITS - FREE-COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. Température de sortie d’eau du chiller ••• ••••• •••• •••• •••• •••• •••• •••• •• •• ••• •• ••• • •• •• ••• • •• •• •• ••• • •••••••••••• •••• ••• • •••••••••••• •••• • •••••••• •••••••• ••• ••••••••••••••••••••• • ••••• •••••• •••••• ••• ••••••••• •••••••••• • • ••••••••••••••••• • • • •••••••• •••• •••• • •••••••••••••• • • ••• • •••••••••••••••• • • •• •••••• ••••• Température air extérieur 70 Code 118 119 150 151 170 172 175 251 351 450 605 650 731 739 740 768 919 923 926 931 932 934 942 943 Brine version kit A Brine version kit B LNO Kit Kit ELN Spring antivibration holders Rubber support (kit) Victaulic Connections Coils protection nets Kit Coils with pre painted fins Desuperheater Compr. Power factor capcitor 0,9 Compressor thermal relays Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Chilled water storage tank Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQMF MODEL 21.1 24.1 28.1 30.1 34.1 18,9 21,3 25,2 27,7 33,3 6,2 7,3 8,4 9,9 10,4 11,3 13,5 15,6 17,6 19 Evaporator water flow rate m³/h 3,5 3,9 4,6 5,1 6,1 Evaporator pressure drop kPa 62 77 92 89 87 COOLING CAPACITY kW 18,4 19,4 23,5 24,4 31,6 HEATING CAPACITY kW COOLING ONLY (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A FREE COOLING (2) PARTIAL HEAT RECOVERY (3) 7 7,8 9,2 10,2 12,2 Heat recovery water flow rate m³/h 1,2 1,4 1,6 1,8 2,1 Heat recovery pressure drop kPa 17 21,6 30,1 12,3 17,7 scroll scroll scroll scroll scroll 1 1 1 1 1 COMPRESSORS Quantity n. Maximum current A 16 21 22 25 31 Starting current A 95 111 118 118 140 Capacity steps n. 1 1 1 1 1 n. 1 1 1 1 1 18 18 18 18,7 27,1 4,7 5,3 6,3 6,9 8,3 1 1 1 1 1 0,4 0,4 0,4 0,6 0,6 1,7 2 2,3 2,6 3,1 1 1 1 1 2 7500 7500 9650 9650 12000 EVAPORATOR Water volume (evaporator + free cooling coil) l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Total air flow m³/h Engaged power kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz 0,5 0,5 0,8 0,8 0,6 1,5 1,5 1,6 1,6 3 R410A R410A R410A R410A R410A 11,3 11,3 11,3 11,5 13,7 1 1 1 1 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW 2,84 2,75 2,73 2,58 3,02 IPLV - ARI Standard 550/590 4,79 4,76 4,53 4,38 5,18 ESEER Eurovent Standard 4,32 4,29 4,09 3,95 4,67 Average sound pressure level [LPm] (4) dB(A) 64,2 64,6 66 65,2 66,4 Sound power level [Lw] (5) dB(A) 80,8 81,2 82,6 81,8 83,6 1/1 1/1 1/1 1/1 2/1 - - - - - 130 130 130 130 210 Length mm 1250 1250 1250 1250 1800 Width mm 1010 1010 1010 1010 1180 Height mm 2010 2010 2010 2010 2060 430 440 440 440 600 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" - - - - - 1" 1" 1" 1" 1 1/4" SOUND LEVEL PUMPING GROUP With 1 pump – 2 poles motor PPF MAX With 2 pumps – 2 poles motor PPF MAX WATER TANK - Volume l DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – Flexible joint - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø ➜ 1. Gross value - Referred to chiller water temperature 12/7°C; 20% Ethylene glycol solution; ambient temperature 35°C, 2. Gross value - Referred to chiller water inlet temperature 15°C; 20% Ethylene glycol solution; ambient temperature 3°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 71 Cooling only and Free cooling - EQMF 21 / 260 | EQMF MODEL 40.1 50.1 52.1 52.2 COOLING CAPACITY kW 37,5 46 47,8 47,7 Compressors power input kW 12,4 16,3 17,2 17,3 23,9 28,5 31,9 31,9 Evaporator water flow rate m³/h 6,9 8,5 8,8 8,8 Evaporator pressure drop kPa 96 94 100 80 COOLING CAPACITY kW 35,7 42,6 43,1 43,1 HEATING CAPACITY kW COOLING ONLY (1) Compressors operating current [OA] A FREE COOLING (2) PARTIAL HEAT RECOVERY (3) 13,8 16,9 17,5 17,5 Heat recovery water flow rate m³/h 2,4 2,9 3 3 Heat recovery pressure drop kPa 22,5 33,9 23,8 23,6 scroll scroll scroll scroll 1 1 2 2 44 COMPRESSORS Quantity n. Maximum current A 34 40 44 Starting current A 174 225 140 140 Capacity steps n. 1 1 2 2 EVAPORATOR n. Water volume (evaporator + free cooling coil) l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Total air flow m³/h Engaged power kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz 1 1 1 1 27,1 27,8 28,8 28,4 9,4 11,4 11,9 11,9 1 1 1 2 0,6 0,6 0,8 0,8 3,4 4,2 4,4 4,4 2 2 2 2 14000 17300 17300 17300 1 1,7 1,7 1,7 3 3,2 3,2 3,2 R410A R410A R410A R410A 13,7 15 15,3 16 1 1 1 2 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW 2,8 2,56 2,54 2,52 IPLV - ARI Standard 550/590 4,63 4,16 4,41 3,97 ESEER Eurovent Standard 4,18 3,75 3,98 3,58 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) 69,4 72,5 70 70 Sound power level [Lw] (5) dB(A) 86,6 89,8 87,2 87,2 2/1 2/1 2/1 2/1 - - - - 210 210 210 210 Length mm 1800 1800 1800 1800 Width mm 1180 1180 1180 1180 Height mm 2060 2060 2060 2060 600 740 700 700 2" 2" 2" 2" - - - - 1 1/4" 1 1/4" 1 1/4" 1 1/4" PUMPING GROUP With 1 pump – 2 poles motor PPF MAX With 2 pumps – 2 poles motor PPF MAX WATER TANK - Volume l DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – Flexible joint - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø 1. Gross value - Referred to chiller water temperature 12/7°C; 20% Ethylene glycol solution; ambient temperature 35°C, 2. Gross value - Referred to chiller water inlet temperature 15°C; 20% Ethylene glycol solution; ambient temperature 3°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 72 58.1 58.2 62.1 65.1 65.2 76.1 76.2 98.1 55,6 55,8 59,1 62,6 62,4 71,7 71,3 92,7 18,7 18,7 20,2 21 20,9 25,4 25,4 32,1 33,6 33,4 35,1 38,2 38,1 48,7 48,6 56,3 10,2 10,3 10,9 11,5 11,5 13,2 13,1 17 91 68 89 101 81 99 79 79 53,9 53,9 56,3 58,8 58,7 65,1 65 82,8 20,4 20,5 21,7 23 22,9 26,3 26,2 34 3,5 3,5 3,7 4 3,9 4,5 4,5 5,9 36,8 32,3 14 40,7 15,5 31,3 20,3 30,6 scroll scroll scroll scroll scroll scroll scroll scroll 2 2 1 2 2 2 2 2 50 50 48,5 62 62 68 68 80 143 143 272 171 171 208 208 265 2 2 1 2 2 2 2 2 1 1 1 1 1 1 1 1 42,2 41,9 42 43,2 42,6 44,5 43,7 62 13,9 14 14,8 15,6 15,6 17,9 17,9 23,2 1 2 1 1 2 1 2 1 0,8 1,2 0,8 0,8 1,2 1 1,2 1,7 5,1 5,1 5,4 5,8 5,8 6,6 6,6 8,6 3 3 3 3 3 3 3 4 21000 21000 22000 23000 23000 25750 25750 35000 1,5 1,5 1,7 2 2 2,5 2,5 2,7 4,5 4,5 4,5 4,5 4,5 4,8 4,8 6,4 R410A R410A R410A R410A R410A R410A R410A R410A 21,7 19,3 18,9 22,1 19,6 28,6 25,5 33,9 1 2 1 1 2 1 2 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,75 2,76 2,7 2,73 2,73 2,57 2,56 2,66 4,91 4,41 4,45 4,62 4,18 4,35 3,88 4,6 4,42 3,98 4,01 4,17 3,77 3,92 3,5 4,14 70,3 70,3 75,1 70,2 70,2 69,4 69,4 68,4 88,2 88,2 93 88,1 88,1 87,3 87,3 87 3/1 3/1 3/1 3/1 3/1 3/1 3/1 4/1 3/2 3/2 3/2 3/2 3/2 3/2 3/2 4/2 360 360 360 360 360 360 360 520 2600 2600 2600 2600 2600 2600 2600 3700 1340 1340 1340 1340 1340 1340 1340 1490 2060 2060 2060 2060 2060 2060 2060 2050 930 920 970 940 930 1000 1000 1470 - - - - - - - - 76,1 76,1 76,1 76,1 76,1 76,1 76,1 88,9 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" ➜ 73 Cooling only and Free cooling - EQMF 21 / 260 | EQMF MODEL 98.2 124.1 124.2 158.1 COOLING CAPACITY kW 91,5 114 112 147 Compressors power input kW 31,9 41,4 41,4 54,6 56 71,3 71,3 92,9 16,8 21 20,6 27 66 74 64 80 COOLING CAPACITY kW 82,3 98,1 97,5 113 HEATING CAPACITY kW COOLING ONLY (1) Compressors operating current [OA] A Evaporator water flow rate m³/h Evaporator pressure drop kPa FREE COOLING (2) PARTIAL HEAT RECOVERY (3) 33,6 41,9 41,2 53,9 Heat recovery water flow rate m³/h 5,8 7,2 7,1 9,3 Heat recovery pressure drop kPa 33,5 32,2 32,7 41 scroll scroll scroll scroll 2 2 2 2 130,8 COMPRESSORS Quantity n. Maximum current A 80 97 97 Starting current A 265 320,5 320,5 375,4 Capacity steps n. 2 2 2 2 EVAPORATOR n. Water volume (evaporator + free cooling coil) l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Total air flow m³/h Engaged power kW Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz 1 1 1 1 63,1 63,7 63,1 65,5 23 28,6 28,2 36,7 2 1 2 1 1,2 2,1 1,6 4 8,5 10,5 10,4 13,5 4 4 4 4 35000 42000 42000 46800 2,7 4,7 4,7 7,1 6,4 11,4 11,4 11,4 R410A R410A R410A R410A 31,3 38,6 42,1 50,9 2 1 2 1 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW 2,64 2,47 2,43 2,38 IPLV - ARI Standard 550/590 4,11 4,07 3,66 3,84 ESEER Eurovent Standard 3,71 3,67 3,3 3,46 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) 68,4 72,3 72,3 74,4 87 90,9 90,9 93 With 1 pump – 2 poles motor PPF MAX 4/1 4/1 4/1 4/1 With 2 pumps – 2 poles motor PPF MAX 4/2 4/2 4/2 4/2 520 520 520 520 Length mm 3700 3700 3700 3700 Width mm 1490 1490 1490 1490 Height mm 2050 2050 2050 2050 kg 1470 1610 1610 1660 - - - - 88,9 88,9 88,9 88,9 2" 2" 2" 2" Sound power level [Lw] (5) dB(A) PUMPING GROUP WATER TANK - Volume l DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – Flexible joint - OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø 1. Gross value - Referred to chiller water temperature 12/7°C; 20% Ethylene glycol solution; ambient temperature 35°C, 2. Gross value - Referred to chiller water inlet temperature 15°C; 20% Ethylene glycol solution; ambient temperature 3°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 74 158.2 180.1 180.2 197.1 197.2 230.1 240.2 260.2 149 169 170 186 183 209 231 258 54,8 60,4 60,5 69,1 69,5 85,6 83,2 99 93,4 103 104 118 117 145 143 168 27,3 31 31,1 34,1 33,7 38,5 42,5 47,5 72 65 68 89 81 97 95 100 113 131 132 145 145 153 165 190 54,5 61,9 62,3 68,1 67,2 76,6 84,9 94,6 9,4 10,7 10,7 11,7 11,6 13,2 14,6 16,3 33,2 31,8 25,6 38,5 29,8 34,7 32,9 40,9 scroll scroll scroll scroll scroll scroll scroll scroll 2 2 2 2 2 3 4 4 130,8 147,4 147,4 164 164 196,2 194 227,8 375,4 459,4 459,4 476 476 440,8 417,5 472,4 2 2 2 2 2 3 4 4 1 1 1 1 1 1 1 1 65 116,2 114,2 124 121,8 104,8 161,2 161,2 37,2 42,2 42,4 45,6 46,3 51,9 54,5 54,5 2 1 2 1 2 1 2 2 2 5,3 4,2 5,3 4,2 6,3 4,2 4,2 13,7 15,5 15,6 16,8 17 19,1 20 20 4 5 5 5 5 5 5 5 46800 53000 53000 54000 54000 56300 69000 69000 7,1 6,8 6,8 7,2 7,2 8,2 9,1 9,1 11,4 14,3 14,3 14,3 14,3 14,3 14,3 14,3 R410A R410A R410A R410A R410A R410A R410A R410A 42,9 73,7 65,8 83,1 102,2 83,7 127 126,6 2 1 2 1 2 1 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,41 2,51 2,53 2,44 2,39 2,23 2,5 2,39 3,53 4,15 3,75 3,99 3,6 4,15 3,79 3,72 3,18 3,74 3,38 3,6 3,25 3,74 3,4 3,34 74,4 74,1 74,1 74,4 74,4 75,4 74,1 74,1 93 93,3 93,3 93,7 93,7 94,7 93,4 93,4 5/1 5/1 5/1 5/1 5/1 5/1 5/1 5/1 5/2 5/2 5/2 5/2 5/2 5/2 5/2 5/2 520 720 720 720 720 720 720 720 3700 4950 4950 4950 4950 4950 4950 4950 1490 1500 1500 1500 1500 1500 1500 1500 2050 2090 2090 2090 2090 2090 2090 2090 1640 2240 2210 2220 2230 2370 2510 2510 - - - - - - - - 88,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 2" 2" 2" 2" 2" 2" 2" 2" 75 Air Cooled Chiller | EQMF PF 22 / 290 cooling only and free cooling Scroll Ductable R410A ooling Capacity from 20 to 260 KW C Size = 29 Refrigerant : R410A EER up to 3,26 ESSEER up to 4,67 Main Functions: REE COOLING F Available with one or 2 cooling circuit 1 or 2 scroll compressors following sizes Condenser coil on only one face Implementation for difficult place Available static pressure 50 to 700 Pa following models Plug fan as STD Available Versions: artial heat recovery P Extra low noise Brine Low ambiant operation up to -10°C STD Picture with hydraulic kit under the unit urovent certified E Easy maintenance Service valves on gas discharge and liquid line Water tank (option) under the unit, optimization for footprint and mass repartition Free cooling coil with 3 way value and ambiant control, management by the unit controller Product Advantages Main accessories and options Free cooling = recovery of «free» energy Ductable unit Horizontal or vertical Blow Indoor implantation Choice mono or bi-circuit Easy acces to component High performances Choice of the sound level Electronic expansion valve from size 98 Standard EC fan motor Remote demand limit via additional elec board Analog set point compensation WORKING LIMITS - FREE-COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. Température de sortie d’eau du chiller ••• ••••• •••• •••• •••• •••• •••• •••• •• •• ••• •• Code 118 119 150 160 170 172 175 251 351 450 460 605 731 739 740 756 757 768 822 919 923 926 931 932 934 942 943 ••• • •• •• ••• • •• •• •• ••• • •••••••••••• •••• ••• • •••••••••••• •••• • •••••••• •••••••• ••• ••••••••••••••••••••• • ••••• •••••• •••••• ••• ••••••••• •••••••••• • • ••••••••••••••••• • • • •••••••• •••• •••• • •••••••••••••• • • ••• • •••••••••••••••• • • •• •••••• ••••• Température air extérieur 76 Brine version kit A Brine version kit B LNO Kit Discharge air plenum with sound attenuator Spring antivibration holders Rubber support (kit) Victaulic Connections Coils protection nets Kit Coils with pre painted fins Desuperheater Kit for Outdoor installation Compr. Power factor capcitor 0,9 Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group LN 1 pump Pumping group LN 2 pumps Chilled water storage tank Supply air plenum mounting kit Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQMF PF MODEL 22.1 24.1 28.1 32.1 36.1 42.1 53.1 21,4 23,9 27,9 31,6 35,2 39,6 51,4 6,6 7,7 9 10,2 11,4 14 17,3 11,9 14,1 16,4 17,9 20,6 26,1 29,8 Evaporator water flow rate m³/h 4 4,4 5,2 5,8 6,5 7,3 9,5 Evaporator pressure drop kPa 75 95 111 113 109 122 113 COOLING CAPACITY kW 18,1 19,5 22,9 26 28,2 29,9 42,3 HEATING CAPACITY kW COOLING ONLY (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A FREE COOLING (2) PARTIAL HEAT RECOVERY (3) 7,4 8,2 9,6 10,9 12,1 13,6 17,7 Heat recovery water flow rate m³/h 1,3 1,4 1,7 1,9 2,1 2,4 3,1 Heat recovery pressure drop kPa 19,1 23,8 32,5 14 17,4 22 37,1 1 1 1 1 1 1 1 Maximum current A 16 21 22 25 31 34 40 Starting current A 95 111 118 118 140 174 225 Capacity steps n. 1 1 1 1 1 1 1 n. 1 1 1 1 1 1 1 15 15 15,2 15,9 16 16,4 24,3 5,2 5,9 6,8 7,8 8,8 10,1 12,8 1 1 1 1 1 1 1 0,4 0,4 0,4 0,6 0,6 0,6 0,6 1,9 2,2 2,5 2,8 3,2 3,7 4,7 1 1 1 1 1 1 2 COMPRESSORS Quantity n. EVAPORATOR Water volume (evaporator + free cooling coil) l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h plug FANS n. Total air flow m³/h 6500 7000 8500 10000 11000 11500 16000 50 50 50 50 50 50 50 Max external static pressure Pa 710 673 464 418 237 134 511 Power input kW 0,6 0,7 1,3 0,7 1,9 2,1 2,3 4,3 4,3 4,3 4,9 4,9 4,9 8,6 R410A R410A R410A R410A R410A R410A R410A 11,3 11,3 11,3 11,5 11,6 11,6 18 1 1 1 1 1 1 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 External static pressure Pa Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz 400/3/50 ENERGY EFFICIENCY INDEXES (1) EER - Energy Efficiency Ratio kW/kW 2,96 2,85 2,74 2,89 2,65 2,45 2,62 ESEER Eurovent Standard 4,39 4,31 3,94 4,63 3,68 3,45 3,77 IPLV - ARI Standard 550/590 4,87 4,78 4,37 5,13 4,09 3,83 4,19 Average sound pressure level [LPm] (4) dB(A) 70,7 72,3 76,4 75,5 77,9 78,9 77,8 Sound power level [Lw] (5) dB(A) 87,3 88,9 93 92,1 94,5 95,5 95 1/1 1/1 1/1 1/1 1/1 2/1 - - - - - - 130 130 130 130 130 130 210 Length mm 1250 1250 1250 1250 1250 1250 1800 Width mm 1010 1010 1010 1010 1010 1010 1180 Height mm 1950 1950 1950 1950 1950 1950 2000 450 460 460 470 470 480 750 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" -- -- -- -- -- -- -- 1" 1" 1" 1" 1" 1" 1 1/4" SOUND LEVEL PUMPING GROUP With 1 pump – 2 poles motor PPF UNI 1/1 With 2 pumps – 2 poles motor PPF UNI WATER TANK - Volume l DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD (6) Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø 1. Gross value - Referred to chiller water temperature 12/7°C; 20% Ethylene glycol solution; ambient temperature 35°C, 2. Gross value - Referred to chiller water inlet temperature 15°C; 20% Ethylene glycol solution; ambient temperature 3°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 – . 77 ➜ Cooling only and Free cooling - EQMF PF 22 / 290 | EQMF PF MODEL 67.1 55.1 55.2 62.1 62.2 71.1 71.2 85.1 COOLING CAPACITY kW 54,1 54,2 60,7 60,9 64,4 68,4 68,3 80,5 Compressors power input kW 18,3 18,2 19,8 19,8 22 22,8 22,7 26,5 33,6 33,4 35,1 35,1 37,4 40,9 40,8 50,4 Evaporator water flow rate m³/h 10 10 11,2 11,2 11,9 12,6 12,6 14,9 Evaporator pressure drop kPa 124 100 139 112 139 157 135 120 COOLING CAPACITY kW 45,7 45,7 50,6 50,6 52,1 55,6 55,5 67,1 HEATING CAPACITY kW COOLING ONLY (1) Compressors operating current [OA] A FREE COOLING (2) PARTIAL HEAT RECOVERY (3) 18,6 18,6 20,9 21 22,2 23,5 23,5 27,7 Heat recovery water flow rate m³/h 3,2 3,2 3,6 3,6 3,8 4,1 4 4,8 Heat recovery pressure drop kPa 26,7 30,6 33,7 13 37,9 42,8 16,4 34,7 2 2 2 2 1 2 2 2 44 44 50 50 48,5 62 62 68 Starting current A 140 140 143 143 272 171 171 208 Capacity steps n. 2 2 2 2 1 2 2 2 n. 1 1 1 1 1 1 1 1 24,3 24,4 24,9 25,4 25,8 25,6 25,7 37,6 13,3 13,3 15 15,1 16,2 17,2 17,1 20,4 1 2 1 2 1 1 2 1 0,8 0,7 0,8 1,1 0,8 0,8 1,2 1 4,9 4,9 5,5 5,5 5,9 6,3 6,3 7,5 2 2 2 2 2 2 2 3 18000 18000 20500 20500 21000 23000 23000 25500 50 50 50 50 50 50 50 50 Max external static pressure Pa 516 516 324 324 263 188 188 580 Power input kW 2,5 2,5 3 3 2,3 4,1 4,1 3,2 9,8 9,8 8,4 8,4 8,4 8,4 8,4 14,7 R410A R410A R410A R410A R410A R410A R410A R410A COMPRESSORS Quantity n. Maximum current A EVAPORATOR Water volume (evaporator + free cooling coil) l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h plug FANS n. Total air flow m³/h External static pressure Pa Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY 18,3 16 18,3 16 18,5 18,7 16,2 28,7 1 2 1 2 1 1 2 1 V/Ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFICIENCY INDEXES (1) EER - Energy Efficiency Ratio kW/kW 2,6 2,62 2,67 2,67 2,65 2,55 2,55 2,71 ESEER Eurovent Standard 3,73 3,92 3,63 3,51 3,56 3,62 3,38 4,18 IPLV - ARI Standard 550/590 4,14 4,35 4,03 3,89 4,02 4,01 3,75 4,63 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) 76,4 76,4 70,3 70,3 80 72,6 72,6 76,5 Sound power level [Lw] (5) dB(A) 93,6 93,6 87,5 87,5 97,2 89,8 89,8 94,4 2/1 2/1 2/1 2/1 2/1 2/1 3/1 PUMPING GROUP With 1 pump – 2 poles motor PPF UNI 2/1 With 2 pumps – 2 poles motor PPF UNI WATER TANK - Volume l 210 - - - - - - 3/2 210 210 210 210 210 210 360 DIMENSIONS Length mm 1800 1800 1800 1800 1800 1800 1800 2600 Width mm 1180 1180 1180 1180 1180 1180 1180 1340 Height mm NET WEIGHT kg 2000 2000 2000 2000 2000 2000 2000 2000 740 740 810 810 790 820 820 1050 2" 2" 2" 2" 2" 2" 2" -- -- -- -- -- -- -- -- 76,1 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/2" HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet (ISO 7/1 - R) Ø Inlet / Outlet – OD (6) Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet (ISO 7/1 - R) Ø 1. Gross value - Referred to chiller water temperature 12/7°C; 20% Ethylene glycol solution; ambient temperature 35°C, 2. Gross value - Referred to chiller water inlet temperature 15°C; 20% Ethylene glycol solution; ambient temperature 3°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 – . 78 85.2 107.1 107.2 135.1 135.2 170.1 170.2 195.1 195.2 220.1 220.2 250.1 265.2 290.2 80,1 103 102 128 126 166 164 182 185 210 214 240 253 277 26,5 34 33,9 43,6 43,6 55 55 55,4 65,9 69,8 70,1 87,2 90 108 50,1 58,9 58,5 74,4 73,7 94,6 93,3 111 111 119 119 147 152 180 14,8 19,1 18,9 23,5 23,2 30,6 30,2 33,6 34,2 38,8 39,4 44,4 46,7 51,3 98 155 139 88 77 107 101 123 117 112 106 124 131 148 67 81,1 80,9 99,5 99 124 123 127 127 163 163 171 173 176 27,6 35,6 35,2 43,9 43,2 57,2 56,3 62,6 63,7 72,3 73,5 82,7 87 95,4 4,8 6,1 6,1 7,6 7,4 9,9 9,7 10,8 11 12,5 12,7 14,2 15 16,4 22,5 33,5 36,7 35,4 36 46,1 35,4 32,6 26,8 43,4 35,7 40,4 34,5 41,6 2 2 2 2 2 2 2 2 2 2 2 3 4 4 68 80 80 97 97 130,8 130,8 147,4 147,4 164 164 196,2 194 294,8 208 265 265 320,5 320,5 375,4 375,4 439,4 439,4 456 456 440,8 417,5 586,8 2 2 2 2 2 2 2 2 2 2 2 3 4 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 37,2 39,7 38,8 56,4 54,7 60,6 57,3 59,9 63,1 81,6 85,2 84,4 87,6 89,2 20,4 25,8 25,5 32 31,6 41,5 40,9 46 46,8 53,6 52,8 60,2 63,9 70 2 1 2 1 2 1 2 1 2 1 2 1 2 2 1,2 1,7 1,2 2,1 1,5 4 2 5,3 3,4 5,3 4,2 6,3 4,2 4,2 7,5 9,5 9,4 11,8 11,6 15,2 15 16,8 17 19,4 19,7 22 23,3 25,5 3 3 3 4 4 4 4 4 4 5 5 5 5 5 25500 32000 32000 40000 40000 52000 52000 52000 52000 62500 62500 64000 64000 64000 50 50 50 50 50 50 50 50 50 50 50 50 50 50 580 224 224 396 396 55 55 55 55 108 108 71 50 50 3,2 6 6 4,8 4,8 10,2 10,2 11,3 11,3 11,7 11,7 12,5 13 13 14,7 14,7 14,7 16,8 16,8 16,8 16,8 16,8 16,8 21 21 21 21 21 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 25,5 32 29,3 35,1 38,6 50,9 42,6 51,9 44 83,1 102,2 83,7 113,3 113,2 2 1 2 1 2 1 2 1 2 1 2 1 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,7 2,57 2,55 2,64 2,6 2,55 2,51 2,73 2,4 2,58 2,62 2,41 2,46 2,29 3,79 3,62 3,36 4,14 3,73 3,54 3,29 3,39 3,18 3,7 3,47 3,85 3,36 3,26 4,2 4,01 3,73 4,6 4,14 3,92 3,65 3,76 3,53 4,1 3,85 4,27 3,73 3,62 76,5 81,3 81,3 74,1 74,1 77,6 77,6 77,6 77,6 77,6 77,6 77,9 78 78 94,4 99,2 99,2 92,7 92,7 96,2 96,2 96,2 96,2 96,8 96,8 97,2 97,3 97,3 3/1 3/1 3/1 4/1 4/1 4/1 4/1 4/1 4/1 5/1 5/1 5/1 5/1 5/1 3/2 3/2 3/2 4/2 4/2 4/2 4/2 4/2 4/2 5/2 5/2 5/2 5/2 5/2 360 360 360 520 520 520 520 520 520 720 720 720 720 720 2600 2600 2600 3700 3700 3700 3700 3700 3700 4950 4950 4950 4950 4950 1340 1340 1340 1490 1490 1490 1490 1490 1490 1500 1500 1500 1500 1500 2000 2000 2000 2000 2000 2000 2000 2000 2000 2040 2040 2040 2040 2040 1050 1240 1240 1690 1690 1800 1780 1850 1820 2320 2330 2490 2670 2720 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 76,1 76,1 76,1 88,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 79 Air Cooled Chiller | EQEF 60 / 300 cooling only free cooling Scroll R410A Cooling Capacity from 64 to 313 KW Size = 17 Refrigerant : R410A EER up to 2,91 ESSEER up to 3,34 Main Functions: REE COOLING F Available with one or 2 cooling circuit Tandem scroll per refrigerant circuit Available Versions: artial heat recovery P Extra low noise Brine low ambiant operation up to -10°C STD Main accessories and options Product Advantages ree cooling = recovery of "free" energy F Tandem scroll compressors per circuit for a highest efficiency and reliability Electronic Expansion valve STD Choice of the sound level partial heat recovery Service valves on gas discharge and liquid line Eurovent certified Easy maintenance Free cooling coil with 3 way value and ambiant control, management by the unit controller WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External Max air temperature External Min air temperature 5 / 15°C -10 / 5°C 45°C -20°C 80 Code 118 119 150 151 170 172 251 450 605 731 739 740 919 923 926 931 Brine version kit A Brine version kit B LNO Kit Kit ELN Spring antivibration holders Rubber support (kit) Coils protection nets Kit Desuperheater Compr. Power factor capcitor 0,9 Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board 932 BACnet MS/TP serial board 942 Serial card for GSM Modem 943 Data Logger EQEF MODEL 60.1 60.2 70.1 70.2 90.1 64 64 73,4 73,2 94,9 20,5 20,5 24,6 24,6 30,9 37,8 37,8 47,8 47,8 55 Evaporator water flow rate m³/h 11,7 11,8 13,5 13,4 17,4 Evaporator pressure drop kPa 112 91 131 111 94 COOLING CAPACITY kW 46,3 46,3 50,2 50,2 61,9 HEATING CAPACITY kW MECHANICAL COOLING (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A FREE COOLING (2) PARTIAL HEAT RECOVERY (3) 23,5 -- 26,9 -- 34,8 Heat recovery water flow rate m³/h 4 -- 4,6 -- 6 Heat recovery pressure drop kPa -- -- -- -- -- scroll scroll scroll scroll scroll 2 2 2 2 2 COMPRESSORS Quantity n. Maximum current A 62 62 68 68 80 Starting current A 171 171 207 207 265 Capacity steps n. 2 2 2 2 2 n. 1 1 1 1 1 22 22 22 22 33 17,4 17,5 20 20 25,9 1 -- 1 -- 1 0,8 -- 1 -- 1,7 5,6 -- 6,4 -- 8,4 6 6 6 6 2 Total air flow m³/h 30000 30000 33000 33000 44000 Power input kW 1,5 1,5 1,5 1,5 3,4 2,4 2,4 2,4 2,4 7,8 R410A R410A R410A R410A R410A 31,6 34,6 32 35,6 42 1 2 1 2 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 EVAPORATOR Water volume (evaporator + free cooling coil) l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h AXIAL FANS n. Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER = Energy Efficiency Ratio kW/kW 2,91 2,91 2,81 2,8 2,77 ESEER Eurovent Standard 4,76 4,57 4,61 4,27 4,61 IPLV = ARI Standard 550/590 5,26 5,13 5,12 4,89 5,07 Average sound pressure level [LPm] (4) dB(A) 66,3 66,3 66,4 66,4 74,2 Sound power level [Lw] (5) dB(A) 83,3 83,3 83,8 83,8 92,3 With 1 pump – 2 poles motor 1/1 1/1 2/1 2/1 2/1 With 2 pumps – 2 poles motor 1/2 1/2 2/2 2/2 2/2 Length mm Width mm 2580 1200 2580 1200 2580 1200 2580 1200 3020 1200 Height mm 1630 1630 1630 1630 1950 830 810 870 850 1170 2" 2" 2" 2" -- -- -- -- -- 76,1 1 1/2" -- 1 1/2" -- 1 1/2" SOUND LEVEL PUMPING GROUP DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet – ISO 7/1 R Ø Inlet / Outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet / Outlet – ISO 7/1 R Ø ➜ 1. Gross value - Referred to chiller water temperature 12/7°C; 20% Ethylene glycol solution; ambient temperature 35°C, 2. Gross value - Referred to chiller water inlet temperature 15°C; 20% Ethylene glycol solution; ambient temperature 3°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 81 Cooling only and Free cooling - EQEF 60 / 300 | EQEF MODEL 90.2 120.1 120.2 135.1 150.1 COOLING CAPACITY kW 93,8 116 114 130 154 Compressors power input kW 30,8 40,7 40,5 47,6 50,9 54,9 70,7 70,5 81,8 88 17,2 21,3 21 23,9 28,3 78 114 103 133 111 61,6 69,3 68,9 71,9 106 MECHANICAL COOLING (1) Compressors operating current [OA] A Evaporator water flow rate m³/h Evaporator pressure drop kPa FREE COOLING (2) COOLING CAPACITY kW PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa -- 42,6 -- 47,7 56,6 -- 7,3 -- 8,2 9,8 -- -- -- -- -- scroll scroll scroll scroll scroll 2 2 2 2 2 80 97 97 113,9 130,8 Starting current A 265 320,5 320,5 358,5 375,4 Capacity steps n. 2 2 2 2 2 n. 1 1 1 1 1 COMPRESSORS Quantity n. Maximum current A EVAPORATOR Water volume (evaporator + free cooling coil) l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h 33 33 33 33 54 25,6 31,1 31,5 45 42,6 -- 1 -- 1 1 -- 2,1 -- 2,1 4 13,6 -- 10,2 -- 11,5 2 2 2 2 3 Total air flow m³/h 44000 48000 48000 50000 66000 Power input kW 3,4 3,4 3,4 3,4 5,1 7,8 7,8 7,8 7,8 11,7 R410A R410A R410A R410A R410A 40,8 42,9 41,4 43,6 62,6 2 1 2 1 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 AXIAL FANS n. Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER = Energy Efficiency Ratio kW/kW 2,74 2,63 2,6 2,55 2,75 ESEER Eurovent Standard 4,36 4,3 4,06 4,17 4,45 IPLV = ARI Standard 550/590 4,92 4,73 4,59 4,6 4,95 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) 74,2 74,4 74,4 75,4 76 Sound power level [Lw] (5) dB(A) 92,3 92,5 92,5 93,5 95,4 With 1 pump – 2 poles motor 2/1 2/1 2/1 2/1 2/1 With 2 pumps – 2 poles motor 2/2 2/2 2/2 2/2 2/2 PUMPING GROUP DIMENSIONS NET WEIGHT Length mm 3020 3020 3020 3020 4400 Width mm 1200 1200 1200 1200 1800 Height mm 1950 1950 1950 1950 1990 kg 1150 1280 1270 1350 1560 HYDRAULIC CONNECTIONS EVAPORATOR Inlet / Outlet – ISO 7/1 R Ø Inlet / Outlet – OD Ø mm -- -- -- -- -- 76,1 76,1 76,1 76,1 88,9 -- 1 1/2" -- 1 1/2" 2” PARTIAL HEAT RECOVERY Inlet / Outlet – ISO 7/1 R Ø 1. Gross value - Referred to chiller water temperature 12/7°C; 20% Ethylene glycol solution; ambient temperature 35°C, 2. Gross value - Referred to chiller water inlet temperature 15°C; 20% Ethylene glycol solution; ambient temperature 3°C. 3. Gross value - Referred to chiller water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744 5. Sound power level [Lw] according to ISO EN 9614 - 2 82 150.2 190.2 200.1 200.2 240.2 270.2 300.2 157 186 187 192 227 269 313 51,1 66,1 68,3 68 85,2 93,3 106 88,3 116 116 115 146 161 182 28,8 34,1 34,3 35,2 41,8 49,4 57,5 101 89 116 113 120 140 172 106 115 116 117 129 172 192 57,4 68,1 68,6 70,4 83,5 98,6 115 9,9 11,7 11,8 12,1 14,4 17 19,8 -- -- -- -- -- -- -- scroll scroll scroll scroll scroll scroll scroll 2 4 2 2 4 4 4 130,8 160 164 164 194 227,8 261,6 375,4 345 466 466 417,5 472,4 506,2 2 4 2 2 4 4 4 1 1 1 1 1 1 1 54 68 54 54 68 84 84 42 50,9 51,6 50,7 61,7 72,8 81,3 2 2 1 2 2 2 2 2 3,4 5,3 3,4 4,2 4,2 16 13,7 16,2 16,4 16,8 20 23,7 27,4 3 3 3 4 4 6 6 66000 72000 72000 76000 88000 108000 126000 5,1 5,1 5,1 6,8 6,8 10,2 10,2 11,7 11,7 11,7 15,6 15,6 23,4 23,4 R410A R410A R410A R410A R410A R410A R410A 64,6 68,4 66,4 67 68 94,2 95,8 2 2 1 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 2,79 2,61 2,55 2,57 2,47 2,6 2,69 4,28 4,2 4 3,97 4,08 4,51 4,49 4,83 4,67 4,45 4,47 4,48 4,96 4,96 76 75,4 75,4 75,4 80,2 81,5 81,5 95,4 94,8 94,8 94,8 100 101,8 101,8 3/1 3/1 3/1 3/1 3/1 4/1 5/1 3/2 3/2 3/2 3/2 3/2 4/2 5/2 4400 3600 4400 4400 3600 4600 4600 1800 2290 1800 1800 2290 2290 2290 1990 2250 1990 1990 2250 2250 2250 1580 1840 1710 1730 1850 2260 2710 -- -- -- -- -- -- -- 88,9 88,9 88,9 88,9 88,9 88,9 88,9 2” 2" 2" 2" 2" 2" 2" 83 Air Cooled Chiller | EQSFA 290 / 1450 cooling only free cooling Screw Class A Energy Class More efficient A+ A B C D E Less efficient classA F G ooling Capacity from 2838 to 1450 KW C Size = 24 Refrigerant : R-134a EER up to 3,15 ESSEER up to 3,77 classA Main Functions: REE COOLING F Available with 2 cooling circuits 2 SCREW compressors mounted on rubber pad Modern design Shell and tube evaporator Main accessories and options Available Versions: xtra low noise E EC fan version Low ambiant operation up to -20°C (Free cooling) Product Advantages LASSE A = high energy efficiency C Free cooling = recovery of "free" energy Large cooling capacity range with SCREW technology with a maximum reliability Electronic Expansion valve STD Linear step capacity control Screen display with graphics symbols for an easy reading Choice of the sound level Specific free cooling heat exchanger remote demand limit via additional elec board Analog set point compensation Eurovent certified Easy maintenance Free cooling coil with 3 way value and ambiant control, management by the unit controller WORKING LIMITS - FREE-COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software. ••• ••••• •••• Chiller outlet water temperature •••• •••• •••• •••• •••• •• •• ••• •• ••• • •• •• ••• • •• •• ••• • •• •• •• ••• • •••••••••••• •••• ••• • •••••••••••• •••• • •••••••• •••••••• ••• ••••••••••••••••••••• • ••••• •••••• •••••• ••• ••••••••• •••••••••• • • ••••••••••••••••• • • • •••••••• •••• •••• • •••••••••••••• • • ••• • •••••••••••••••• • • •• ••••• ••••• Ambiant air temperature 84 Code 101 143 170 171 175 351 605 650 731 739 740 769 770 919 923 926 931 932 934 942 943 EC Fan Glycol free Spring antivibration holders Rubber antivibration holders Victaulic Connections Coils with pre painted fins Compr. Power factor capcitor 0,9 Compressor thermal relays Safety water flow switch Pumping group 1 pump Pumping group 2 pumps Pumping group 1 pump + 1 pump stdby Pumping group 2 pumps + 1 pump stdby Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board MP.COM expansion card Serial card for GSM Modem Data Logger EQSFA MODEL 290 310 330 360 380 288 305 329 352 373 MECHANICAL COOLING (1) COOLING CAPACITY kW Compressors power input kW 79 85 90,2 96 102 135 143 152 160 161 51,6 54,6 58,9 63,1 66,8 Plant exchanger pressure drop kPa 28 24 26 29 25 COOLING CAPACITY kW Free-cooling coil pressure drop kPa Free-cooling coil volume l 312 16,9 244 316 18,9 244 386 27 324 422 30,5 332 426 30,2 332 57,3 60,7 65,4 70 74,2 Compressors operating current [OA] A Plant exchanger water flow rate m³/h FREE-COOLING (2) PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Heat recovery water flow rate m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity n. 9,9 10,5 11,3 12,1 12,8 5 5,2 5,4 5,2 5,6 twin-screw twin-screw twin-screw twin-screw twin-screw 2 2 2 2 2 Maximum current A 163,4 179,2 190,5 201,8 205 Starting current A 350,7 356,6 392,6 403,9 382,5 Capacity steps n. 25…100% 25…100% 25…100% 25…100% 25…100% 1 1 1 1 1 160 143 256 256 256 90 100 127 127 127 2 2 2 2 2 3,2 3,2 4,1 5 5 20 20 20 20 20 6 6 7 8 8 Total air flow m³/h 122376 119280 142772 163168 159040 Power input kW 12,4 12,5 14,4 16,5 16,7 23,4 23,4 27,3 31,2 31,2 R134a R134a R134a R134a R134a 110 146 145 145 194 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,15 3,13 3,14 3,13 3,14 3,59 3,53 3,57 3,56 3,55 Average sound pressure level [LPm] (4) dB(A) 72,4 72,8 72,5 72,7 71,3 Sound power level [Lw] (5) dB(A) 92,1 92,5 92,7 92,9 91,5 GE65/1 GE65/1 GE65/1 GE65/1 GE65/1 -- -- -- -- -- GE65/2 GE65/2 GE65/2 GE65/2 GE65/2 -- -- -- -- -- Length mm 3520 3520 4490 4490 4490 Width mm 2260 2260 2260 2260 2260 Height mm 2550 2550 2550 2550 2550 kg 5330 5923 6633 6638 6857 168,3 168,3 168,3 168,3 168,3 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" EVAPORATOR n. Water volume Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h AXIAL FANS n. Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW ESEER - Eurovent Standard SOUND LEVEL PUMPING GROUP 1 pump in operation GE 2 pumps in operation GE 1 pump in operation + 1 reserve pump GE 2 pumps in operation + 1 reserve pump GE DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS PLANT WATER EXCHANGER Inlet/outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M Ø ➜ 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature; 20% Ethylene glycol solution. 2. Gross value - Referred to water inlet temperature at 15°C; 3°C ambient temperature; 20% Ethylene glycol solution 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 85 Cooling only and Free cooling - EQSFA 290 / 1450 | EQSFA MODEL 420 460 490 540 590 COOLING CAPACITY kW 412 457 484 532 581 Compressors power input kW 115 125 134 150 165 196 204 226 247 269 73,8 81,9 86,7 95,3 104 Plant exchanger pressure drop kPa 31 37 51 51 51 COOLING CAPACITY kW Free-cooling coil pressure drop kPa Free-cooling coil volume l 441 36,1 332 544 53,1 402 554 58,8 402 571 69,6 402 585 81,2 402 MECHANICAL COOLING (1) Compressors operating current [OA] A Plant exchanger water flow rate m³/h FREE-COOLING (2) PARTIAL HEAT RECOVERY (3) 82 90,9 96,3 106 116 Heat recovery water flow rate m³/h HEATING CAPACITY kW 14,1 15,7 16,6 18,2 19,9 Heat recovery pressure drop kPa 5,3 4,9 5,2 5,6 5,7 twin-screw twin-screw twin-screw twin-screw twin-screw 2 2 2 2 2 Maximum current A 235,6 269,6 288,2 309,3 330,4 Starting current A 468,8 629,8 639,1 790,1 811,2 Capacity steps n. 25…100% 25…100% 25…100% 25…100% 25…100% COMPRESSORS Quantity n. EVAPORATOR n. 1 1 1 1 1 247 247 247 223 223 143 143 143 172 172 2 2 2 2 2 5 5 6,8 6,8 6,8 20 20 30 30 30 8 10 10 10 10 Total air flow m³/h 159040 198800 198800 198800 198800 Power input kW 16,7 20,9 20,9 20,9 20,9 31,2 39 39 39 39 R134a R134a R134a R134a R134a 194 241 241 241 241 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Water volume Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h AXIAL FANS n. Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW ESEER - Eurovent Standard 3,13 3,13 3,13 3,11 3,13 3,52 3,53 3,52 3,52 3,55 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) 71,7 71,4 75,6 75,8 76 Sound power level [Lw] (5) dB(A) 91,9 92,1 96,2 96,5 96,7 GE65/1 GE65/1 GE65/1 GE65/1 GE65/1 -- -- -- -- -- GE65/2 GE65/2 GE65/2 GE65/2 GE65/2 -- -- -- -- -- Length mm 4490 5484 5484 5484 5484 Width mm 2260 2260 2260 2260 2260 Height mm 2550 2550 2550 2550 2550 kg 6895 8018 8030 8182 8304 219,1 219,1 219,1 219,1 219,1 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" PUMPING GROUP 1 pump in operation GE 2 pumps in operation GE 1 pump in operation + 1 reserve pump GE 2 pumps in operation + 1 reserve pump GE DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS PLANT WATER EXCHANGER Inlet/outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature; 20% Ethylene glycol solution. 2. Gross value - Referred to water inlet temperature at 15°C; 3°C ambient temperature; 20% Ethylene glycol solution 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 86 630 680 720 790 860 910 960 1050 1110 629 670 715 786 859 905 951 1048 1108 176 189 200 221 242 257 272 303 318 291 309 324 332 339 383 426 483 500 113 120 128 141 154 162 170 188 199 62 66 70 54 61 66 70 46 51 637 19,3 482 715 24,6 562 754 26,6 562 846 33,2 648 895 38,8 648 909 42,5 648 923 46,4 648 947 55,1 648 1035 67,7 726 125 133 142 156 171 180 189 209 221 21,6 23 24,5 27 29,5 31 32,6 35,9 38 6 6,4 6,5 6,4 6,8 6,6 6,9 7 6,9 twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw 2 2 2 2 2 2 2 2 2 366,8 390,4 414 444,1 474,2 505 535,8 615,4 662,5 544,4 544,4 568 581 611,1 690,1 720,9 826,7 1010,7 25…100% 25…100% 25…100% 25…100% 25…100% 25…100% 25…100% 25…100% 25…100% 1 1 1 1 1 1 1 1 1 247 238 238 370 370 359 359 348 348 143 154 154 220 220 241 241 265 265 2 2 2 2 2 2 2 2 2 6,8 8,6 10,4 10,4 10,4 13,1 15,8 19,4 21,2 30 35 40 40 40 45 50 50 50 12 13 14 15 16 16 16 16 18 238560 261794 278320 302070 318080 318080 318080 318080 357840 25 27 29,2 31,1 33,4 33,4 33,4 33,4 37,6 46,8 50,7 54,6 58,5 62,4 62,4 62,4 62,4 70,2 R134a R134a R134a R134a R134a R134a R134a R134a R134a 289 295 337 340 389 389 389 389 436 2 2 2 2 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,13 3,1 3,12 3,12 3,12 3,12 3,11 3,12 3,12 3,68 3,58 3,59 3,55 3,57 3,52 3,56 3,76 3,72 76,7 77,9 79 79,3 79,9 79,8 79,6 78,1 79,5 97,7 99,3 100,4 101,1 101,7 101,6 101,4 99,9 101,7 GE65/1 GE65/1 GE65/1 -- -- -- -- -- -- -- -- -- GE65/11 GE65/11 GE65/11 GE65/11 GE65/11 GE65/11 GE65/2 GE65/2 GE65/2 -- -- -- -- -- -- -- -- -- GE65/21 GE65/21 GE65/21 GE65/21 GE65/21 GE65/21 6428 7398 7398 8767 8767 8767 8767 8767 9737 2260 2260 2260 2260 2260 2260 2260 2260 2260 2550 2550 2550 2550 2550 2550 2550 2550 2550 9086 9669 9872 11754 12233 12267 12277 12376 13934 219,1 219,1 219,1 219,1 219,1 273 273 273 273 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" ➜ 87 Cooling only and Free cooling - EQSFA 290 / 1450 | EQSFA MODEL 1170 1240 1310 1380 1450 1170 1239 1311 1377 1445 334 356 379 396 414 517 558 599 644 688 Plant exchanger water flow rate m³/h 210 222 235 247 259 Plant exchanger pressure drop kPa 56 61 45 50 54 COOLING CAPACITY kW Free-cooling coil pressure drop kPa Free-cooling coil volume l 1174 91,8 804 1191 90,9 804 1208 100,1 804 1292 42 884 1339 23,8 964 MECHANICAL COOLING (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A FREE-COOLING (2) PARTIAL HEAT RECOVERY (3) 233 247 261 274 288 Heat recovery water flow rate m³/h HEATING CAPACITY kW 40,1 42,5 44,9 47,2 49,5 Heat recovery pressure drop kPa 6,8 6,5 7 6,9 7,1 twin-screw twin-screw twin-screw twin-screw twin-screw 2 2 2 2 2 COMPRESSORS Quantity n. Maximum current A 709,6 753,6 797,6 846,8 896 Starting current A 1057,8 1137,8 1181,8 1274,8 1324 Capacity steps n. 25…100% 25…100% 25…100% 25…100% 25…100% 1 1 1 1 1 348 620 620 620 620 265 385 385 385 385 2 2 2 2 2 23 25,7 28,4 32 35,6 50 60 60 60 60 20 20 20 22 24 Total air flow m³/h 397600 397600 397600 437360 477120 Power input kW 41,7 41,7 41,7 45,9 50,1 78 78 78 85,8 93,6 R134a R134a R134a R134a R134a 482 482 482 530 578 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,11 3,12 3,12 3,12 3,11 3,72 3,72 3,77 3,72 3,72 81,5 81,5 81,5 81,4 81,3 103,9 103,9 103,9 104,1 104,2 EVAPORATOR n. Water volume Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Water volume l Max water flow rate m³/h AXIAL FANS n. Plate current [FLA] A REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW ESEER - Eurovent Standard SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) PUMPING GROUP 1 pump in operation GE 2 pumps in operation GE 1 pump in operation + 1 reserve pump GE -- -- -- -- -- GE65/11 GE65/11 GE65/11 GE65/11 GE65/11 -- -- -- -- -- GE65/21 GE65/21 GE65/21 GE65/21 GE65/21 Length mm 10660 10660 10660 11630 12600 Width mm 2260 2260 2260 2260 2260 Height mm 2550 2550 2550 2550 2550 15142 15402 15422 16101 16780 273 323,9 323,9 323,9 323,9 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 pumps in operation + 1 reserve pump GE DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS PLANT WATER EXCHANGER Inlet/outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet/outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature; 20% Ethylene glycol solution. 2. Gross value - Referred to water inlet temperature at 15°C; 3°C ambient temperature; 20% Ethylene glycol solution 3. Gross value - Referred to chilled water temperature 12/7°C; 35°C ambient temperature and hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 88 Water Cooled Chillers 89 Water Cooled Chiller | EWNL 06 / 30 Cooling only Scroll R410A ❯❯Cooling Capacity from 5 to 30 KW ❯❯Size = 10 ❯❯Refrigerant : R410A ❯❯EER up to 4.84 ❯❯ESSEER up to 6.68 Main Functions: ❯❯Solution for domestic and small offices installation ❯❯Scroll compressor ❯❯Evaporator Heat plate exchanger ❯❯Condenser Heat plate exchanger Available Versions: ❯❯One phase up to the 13 KW ❯❯3 phases on the full range ❯❯Heat pump version (see EWNH range) ❯❯Remote condenseur cooling only (see EWNL RC Main accessories and options Code 450 610 920 923 1002 range) ❯❯Remote condenseurheat pump (see EWNH RC range) Product Advantages ❯❯Simple and reliable ❯❯Plug and play ❯❯Microprocessor control ❯❯3 speed circulating pump as STD (evap) ❯❯Signal 0 10 V for 2 ways valve management on condenseur side ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software Evaporator outlet temperature (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit -5 -10 -13 20 25 30 35 40 45 50 55 60(°C) Condenser water outlet temperature 90 Desuperheater Noise deading cup on compresseur Remote control kit COM MBUS/JBUS serial board Condensing control with 2 way valve EWNL MODEL 06M 08M 10M 13M 06T COOLING CAPACITY (1) kW 5,7 7,4 11,1 14,1 5,7 Compressor power input kW 1,4 1,8 2,4 3 1,4 6,5 8,2 11,9 14,9 2,8 1 1 Compressor operating current [OA] A EVAPORATOR Qty Water flow rate m³/h Pressure drop kPa CONDENSER Water flow m³/h 0,98 1,27 1,91 2,41 0,98 35 33 37 40 35 1 1 1 1 1 1,23 1,6 2,34 2,95 1,23 Pressure drops kPa 54 49 53 58 53 HEATING CAPACITY kW PARTIAL HEAT RECOVERY (2) 0,9 1,2 1,7 2,2 0,9 Water flow rate m³/h 0,15 0,2 0,3 0,38 0,15 Pressure drop kPa 0,25 0,41 0,93 1,48 0,25 scroll scroll scroll scroll scroll 1 1 1 1 1 COMPRESSORS Quantity n. Maximum current A 12,8 17,1 21 31 4,7 Starting current A 60 67 98 115,5 28 Capacity steps n. 1 1 1 1 1 n. 1 1 1 1 1 0,5 0,7 0,9 1,1 0,5 1,5 2 2,7 3,5 1,4 EVAPORATOR Water volume l Max water flow rate m³/h CONDENSER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY V/Ph/Hz 0,5 0,7 0,9 1,1 0,5 1,8 2,4 3,2 4,1 1,7 1 1 1 1 1 0,1 0,1 0,1 0,1 0,1 0,4 0,5 0,6 0,8 0,3 R410A R410A R410A R410A R410A 0,7 0,9 1,1 1,4 0,7 1 1 1 1 1 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50+N 4,12 4,09 4,63 4,7 4,11 ENERGY EFFIFICIENCY INDEXES EER – Energy Efficiency Ratio kW/kW ESEER – Eurovent Standard 6,01 6,23 6,28 6,54 6,26 IPLV – ARI Standard 550/590 6,39 6,62 6,68 6,95 6,65 Sound pressure level [Lp] (3) dB(A) 42 42 44 44 42 56,2 56,2 58,2 58,2 56,2 Length mm 555 555 555 555 555 Width mm 650 650 650 650 650 Height mm 900 900 900 900 900 88,7 91,4 101,5 106,3 88,7 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1" 1" 1" 1" 1" SOUND LEVEL Sound power level [Lw] (4) dB(A) DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS EVAPORATOR / CONDENSER Inlet / outlet – ISO228/1-G M Ø PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 3. Sound pressure level [Lp] 1m far according to ISO EN 3744. 4. Sound power level [Lw] according to ISO EN 9614 - 2 91 ➜ Cooling only - EWNL 06 / 30 | EWNL MODEL 08T 10T 13T 15T COOLING CAPACITY (1) kW 7,3 10,4 13,3 15,1 Compressor power input kW 1,8 2,3 2,9 3,4 3,6 4,1 5 6,4 Compressor operating current [OA] A EVAPORATOR Qty 1 Water flow rate m³/h Pressure drop kPa CONDENSER 1,25 1,78 2,29 2,58 32 36 40 37 1 1 1 1 1,57 2,2 2,81 3,2 Pressure drops kPa 48 53 57 53 HEATING CAPACITY kW 1,1 1,6 2,1 2,4 Water flow m³/h PARTIAL HEAT RECOVERY (2) Water flow rate m³/h 0,2 0,28 0,36 0,4 Pressure drop kPa 0,4 0,81 1,33 0,45 COMPRESSORS Quantity n. Maximum current A scroll scroll scroll scroll 1 1 1 1 6,5 8 10,3 11,8 Starting current A 38 43 51,5 64 Capacity steps n. 1 1 1 1 EVAPORATOR n. Water volume l Max water flow rate m³/h CONDENSER 1 1 1 1 0,7 0,9 1,1 1,2 1,9 2,5 3,3 3,8 0,7 0,9 1,1 1,2 2,2 3 3,9 4,5 1 1 1 1 0,1 0,1 0,1 0,2 0,4 0,6 0,8 0,9 R410A R410A R410A R410A n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY V/Ph/Hz 0,9 1,1 1,4 1,5 1 1 1 1 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 4,15 4,48 4,55 4,43 ENERGY EFFIFICIENCY INDEXES EER – Energy Efficiency Ratio kW/kW ESEER – Eurovent Standard 6,41 6,62 6,49 6,38 IPLV – ARI Standard 550/590 6,81 7,04 6,9 6,78 SOUND LEVEL Sound pressure level [Lp] (3) dB(A) 42 44 44 47 56,2 58,2 58,2 61,2 Length mm 555 555 555 555 Width mm 650 650 650 650 Height mm 900 900 900 900 91,4 101,5 106,3 114,5 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1” 1” 1" 1" Sound power level [Lw] (4) dB(A) DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS EVAPORATOR / CONDENSER Inlet / outlet – ISO228/1-G M Ø PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 3. Sound pressure level [Lp] 1m far according to ISO EN 3744. 4. Sound power level [Lw] according to ISO EN 9614 - 2 92 17T 20T 25T 30T 17,4 20,1 24,8 30,5 4 4,5 5,6 6,3 7,4 9,2 11,2 12,7 1 1 1 1 2,99 3,45 4,26 5,24 43 40 40 44 1 1 1 1 3,7 4,26 5,26 6,38 61 55 53 49 2,7 3,1 3,9 4,8 0,47 0,54 0,67 0,82 0,61 0,81 1,23 1,87 scroll scroll scroll scroll 1 1 1 1 15 15 21 22 75 101 111 118 1 1 1 1 1 1 1 1 1,3 1,6 2 2,4 4,4 5 6,3 7,4 1,3 1,6 2 2,4 5,2 5,9 7,4 8,7 1 1 1 1 0,2 0,2 0,2 0,2 1,1 1,2 1,5 1,7 R410A R410A R410A R410A 1,8 1,8 2,5 3,1 1 1 1 1 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 4,37 4,48 4,44 4,84 6,53 6,4 6,47 6,68 6,94 6,8 6,88 7,1 51 48 50 50 65,2 62,2 64,2 64,2 555 555 555 555 650 650 650 650 900 900 900 900 116 118,5 141,7 147,4 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1" 1" 1" 1" 93 Water Cooled Chiller | EWNL RC 06 / 30 Cooling only Scroll Remote condenser R410A ❯❯Cooling Capacity from 5 to 30 KW ❯❯Size = 13 ❯❯Refrigerant : R410A ❯❯EER up to 4.84 ❯❯ESSEER up to 6.68 Main Functions: ❯❯Remote condenseur ❯❯Solution for domestic and small offices installation ❯❯Scroll compressor ❯❯Evaporator Heat plate exchanger Available Versions: ❯❯One phase up to the 13 KW ❯❯3 phases on the full range ❯❯Heat pump version (see EWNH range) ❯❯Cooling only (see EWNL range) ❯❯Remote condenseurheat pump (see EWNH RC Main accessories and options Code 450 610 764 920 923 range) Desuperheater Noise deading cup on compresseur Ballon tampon Remote control kit COM MBUS/JBUS serial board Product Advantages ❯❯Simple and reliable ❯❯Plug and play ❯❯Microprocessor control ❯❯3 speed circulating pump as STD (evap) For general caracteristics, cf EWNL data page 88, for performances see software selection program WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Evaporator Leaving water temperature (sans glycol) Evaporator Leaving water temperature (avec glycol max 40%) 5 / 20°C -12 / 5°C 94 95 Water Cooled Chiller | EWML 27 / 570 Cooling only Scroll R410A ❯❯Cooling Capacity from 23 to 670 KW ❯❯Size = 33 ❯❯Refrigerant : R410A ❯❯EER up to 4.40 ❯❯ESSEER up to 6.51 Main Functions: ❯❯Scroll compressor ❯❯Evaporator Heat plate exchanger ❯❯Condenser Heat plate exchanger Available Versions: ❯❯Mono ou Bo-circuit ❯❯Partial heat recovery available ❯❯Heat pump version reversible on refrigerant circuit Main accessories and option Code 118 119 172 175 220 450 605 919 923 926 931 (see EWMH range) ❯❯Remote condenseur cooling only (see EWML RC range) ❯❯Remote condenseurheat pump (see EWMH RC range) ❯❯Brine version Product Advantages ❯❯Plug and play ❯❯Leaving condenseur Temperature up to 60°C ❯❯Microprocessor control universal dialog, easy to read and acces to all 932 942 943 1002 informations ❯❯Electronic expansion valve STD from the 175 size ❯❯Signal 0 10 V for 2 ways valve management on condenseur side ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software Evaporator outlet temperature (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit -5 -10 -13 20 25 30 35 40 45 50 55 60(°C) Condenser water outlet temperature 96 Brine version kit A Brine version kit B Rubber support (kit) Victaulic Connections Electronic expansion valve Desuperheater Compr. Power factor capcitor 0,9 Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board Serial card for GSM Modem Data Logger Condensing control with 2 way valve EWML MODEL T 27 P1 T 30 P1 T 33 P1 T 40 P1 T 40 P2 T 40 P2 COOLING CAPACITY (1) kW 29,1 32,9 36,6 41,3 47,6 48,5 Compressor power input kW 6,4 7,2 8,2 10,1 11,4 11,5 12,8 13,7 16 21 22,7 22,9 Compressor operating current [OA] A EVAPORATOR Qty Water flow rate m³/h 5 5,7 6,3 7,1 8,2 8,3 Pressure drop kPa 55 56 50 37 46 28 CONDENSER 6,1 7 7,8 8,9 10,2 10,4 Pressure drops kPa Water flow m³/h 69 63 64 47 57 38 HEATING CAPACITY kW 4,5 5,1 5,7 6,4 7,4 -- PARTIAL HEAT RECOVERY (2) Water flow rate m³/h 0,8 0,9 1 1,1 1,3 -- Pressure drop kPa 7,3 9,3 11,5 4,9 6,5 -- scroll scroll scroll scroll scroll scroll COMPRESSORS Quantity n. Maximum current A 1 1 1 1 2 2 22 25 31 34 42 42 Starting current A 118 118 140 173 132 132 Capacity steps n. 1 1 1 1 2 2 n. 1 1 1 1 1 1 EVAPORATOR Water volume l Max water flow rate m³/h CONDENSER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY V/Ph/Hz 2,8 2,8 2,8 3,1 3,1 3,6 7 7,9 8,8 9,9 11,4 11,6 1 1 1 1 1 1 2,8 2,8 2,8 3,1 3,1 3,6 8,6 9,7 10,9 12,5 14,3 14,6 1 1 1 1 1 -- 0,4 0,4 0,4 0,6 0,6 -- 1,1 1,2 1,4 1,6 1,8 -- R410A R410A R410A R410A R410A R410A 2,9 2,9 3 3,9 4,2 5 1 1 1 1 1 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFIFICIENCY INDEXES EER – Energy Efficiency Ratio kW/kW 4,55 4,56 4,44 4,09 4,18 4,22 ESEER – Eurovent Standard 6,36 6,32 5,97 6,14 5,34 6,27 IPLV – ARI Standard 550/590 6,76 6,72 6,35 6,53 5,68 6,67 Sound pressure level [Lp] (3) dB(A) 50 51 52 53 53 53 65,4 66,4 67,4 68,8 68,9 68,9 1000 1000 1000 1000 1200 1200 SOUND LEVEL Sound power level [Lw] (4) dB(A) DIMENSIONS Length mm NET WEIGHT Width mm 650 650 650 650 750 750 Height mm 1400 1400 1400 1400 1700 1700 258 260 270 281 440 450 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" -- -- -- -- -- -- 1" 1" 1" 1" 1" -- kg HYDRAULIC CONNECTIONS EVAPORATOR / CONDENSER Inlet / outlet – ISO228/1-G M Ø Inlet / outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 3. Sound pressure level [Lp] 1m far according to ISO EN 3744. 4. Sound power level [Lw] according to ISO EN 9614 - 2 97 ➜ Cooling only - EWML 27 / 570 | EWML MODEL T 48 P2 T 48 P2 T 54 P2 T 54 P2 T 60 P2 COOLING CAPACITY (1) kW 56,9 56,7 65,4 64,2 69,8 Compressor power input kW 13,2 12,9 15,1 14,6 16,8 26,2 25,8 28,3 27,7 32,5 Water flow rate m³/h 9,8 9,7 11,2 11 12 Pressure drop kPa 47 29 50 28 43 12,1 12,1 13,9 13,6 15 57 38 60 37 51 Compressor operating current [OA] A EVAPORATOR Qty CONDENSER Water flow m³/h Pressure drops kPa PARTIAL HEAT RECOVERY (2) HEATING CAPACITY kW 8,9 -- 10,2 -- 10,9 Water flow rate m³/h 1,5 -- 1,8 -- 1,9 Pressure drop kPa 9,3 -- 8 -- 9,2 scroll scroll scroll scroll scroll 2 2 2 2 2 COMPRESSORS Quantity n. Maximum current A 44 44 50 50 62 Starting current A 140 140 143 143 171 Capacity steps n. 2 2 2 2 2 n. 1 1 1 1 1 3,1 4,2 3,9 4,2 3,9 13,7 13,6 15,7 15,4 16,8 1 1 1 1 1 3,1 4,2 3,9 4,2 3,9 16,9 16,9 19,5 19 21 1 -- 1 -- 1 0,6 -- 0,8 -- 0,8 2,1 -- 2,5 -- 2,6 R410A R410A R410A R410A R410A EVAPORATOR Water volume l Max water flow rate m³/h CONDENSER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY V/Ph/Hz 4,3 5,7 5,7 5,7 5,8 1 2 1 2 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,31 4,4 4,33 4,4 4,15 ENERGY EFFIFICIENCY INDEXES EER – Energy Efficiency Ratio kW/kW ESEER – Eurovent Standard 5,59 6,47 5,54 6,52 5,21 IPLV – ARI Standard 550/590 5,94 6,88 5,88 6,93 5,54 Sound pressure level [Lp] (3) dB(A) 53 53 54 54 55 68,9 68,9 69,9 69,9 70,9 Length mm 1200 1200 1200 1200 1200 Width mm 750 750 750 750 750 Height mm 1700 1700 1700 1700 1700 444 455 455 468 460 2" 2" 2" 2" 2" -- -- -- -- -- 1" -- 1" -- 1" SOUND LEVEL Sound power level [Lw] (4) dB(A) DIMENSIONS NET WEIGHT kg HYDRAULIC CONNECTIONS EVAPORATOR / CONDENSER Inlet / outlet – ISO228/1-G M Ø Inlet / outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 3. Sound pressure level [Lp] 1m far according to ISO EN 3744. 4. Sound power level [Lw] according to ISO EN 9614 - 2 98 T 60 P2 T 70 P2 T 70 P2 T 90 P2 T 90 P2 T 120 P2 T 120 P2 T 150 P2 T 150 P2 70,4 83,4 83,1 108 107 135 134 175 173 16,5 20,6 20 26,2 25,7 33,2 32,6 42,3 41,6 31,9 41,9 41,3 48,3 47,7 61 60,5 75,5 75,1 12,1 14,3 14,3 18,5 18,4 23,1 23 30 29,7 28 50 28 46 29 48 38 46 42 15 18 17,8 23,2 23 29,1 28,8 37,5 37,2 36 60 37 52 36 53 47 45 47 -- 13 -- 16,9 -- 21 -- 27,2 27 -- 2,2 -- 2,9 -- 3,6 -- 4,7 4,7 8,3 -- 7,7 -- 7,5 -- 8,1 -- 10,5 scroll scroll scroll scroll scroll scroll scroll scroll scroll 2 2 2 2 2 2 2 2 2 62 68 68 80 80 97 97 131 131 171 207 207 265 265 321 321 375 375 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 4,2 4,7 6,4 5,8 6,7 7,2 8,3 8,7 12,3 16,9 20 20 25,9 25,8 32,3 32,2 42 41,6 1 1 1 1 1 1 1 1 1 4,2 4,7 6,4 5,8 6,7 7,2 8,3 8,7 12,3 21 25,2 24,9 32,5 32,2 40,7 40,3 52,5 52,1 -- 1 -- 1 -- 1 -- 1 2 -- 1 -- 1,7 -- 2,1 -- 4 2 x 1,0 -- 3,1 -- 4,1 -- 5,1 -- 6,6 6,5 R410A R410A R410A R410A R410A R410A R410A R410A R410A 5,7 6,6 8,1 8,7 10,4 10,7 12,7 12,4 17 2 1 2 1 2 1 2 1 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,27 4,05 4,16 4,12 4,16 4,07 4,11 4,14 4,16 5,93 5,56 6,45 5,18 6,06 5,23 6,1 5,08 6,13 6,3 5,91 6,86 5,5 6,44 5,56 6,48 5,4 6,52 55 56 56 61 61 64 64 64 64 70,9 71,9 71,9 76,9 76,9 80,1 80,1 81 81 1200 1200 1200 1200 1200 1200 1200 1800 1800 750 750 750 750 750 750 750 1200 1200 1700 1700 1700 1700 1700 1700 1700 1740 1740 485 465 495 715 760 775 788 1022 1030 2" 2" 2" -- -- -- -- -- -- -- -- -- 73,1 73,1 73,1 73,1 73,1 73,1 -- 1" -- 1 1/4" -- 1 1/4" -- 2" 2 x 1" ➜ 99 Cooling only - EWML 27 / 570 | EWML MODEL T 170 P4 T 175 P3 T 190 P4 T 200 P2 T 200 P2 COOLING CAPACITY (1) kW 200 199 214 229 227 Compressor power input kW 45,8 49,8 54,3 53,4 53,3 88,9 91,5 95,8 95,2 95,5 Compressor operating current [OA] A EVAPORATOR Qty Water flow rate m³/h Pressure drop kPa 34,3 34,2 36,8 39,2 38,9 42 54 34 46 53 42,6 43,1 46,6 48,8 48,5 70 51 42 62 71 CONDENSER Water flow m³/h Pressure drops kPa PARTIAL HEAT RECOVERY (2) HEATING CAPACITY kW 31,2 31,1 33,5 35,6 35,3 Water flow rate m³/h 5,4 5,4 5,8 6,1 6,1 Pressure drop kPa 11 8 7,4 10,6 8,2 scroll scroll scroll scroll scroll 4 3 4 2 2 Maximum current A 148 146 160 164 164 Starting current A 333 369 345 466 466 Capacity steps n. 4 3 4 2 2 n. 1 1 1 1 1 12,3 11,1 20,3 20,7 20,3 48 47,9 51,5 54,9 54,5 1 1 1 1 1 12,3 11,1 20,3 20,3 21,2 59,6 60,3 65,2 68,3 67,9 2 1 2 1 2 2 x 1,7 5,3 2 x 1,7 5,3 2 x 1,7 7,5 7,5 8,1 8,6 8,5 R410A R410A R410A R410A R410A COMPRESSORS Quantity n. EVAPORATOR Water volume l Max water flow rate m³/h CONDENSER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY V/Ph/Hz 17,8 16 23,9 22,4 22,8 2 1 2 1 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,37 4 3,94 4,29 4,26 ENERGY EFFIFICIENCY INDEXES EER – Energy Efficiency Ratio kW/kW ESEER – Eurovent Standard 5,29 6,33 6,02 5,29 6,11 IPLV – ARI Standard 550/590 5,76 6,73 6,8 5,62 6,49 Sound pressure level [Lp] (3) dB(A) 64 65,8 64 64 64 Sound power level [Lw] (4) dB(A) 81 82,8 81 81 81 Length mm 1800 1800 1800 1800 1800 SOUND LEVEL DIMENSIONS NET WEIGHT Width mm 1200 1200 1200 1200 1200 Height mm 1740 1740 1740 1740 1740 kg 1130 1152 1315 1085 1115 -- -- -- -- -- 73,1 73,1 88,9 88,9 88,9 2 x 1 1/4" 2" 2 x 1 1/4" 2" 2 x 1 1/4" HYDRAULIC CONNECTIONS EVAPORATOR / CONDENSER Inlet / outlet – ISO228/1-G M Ø Inlet / outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 3. Sound pressure level [Lp] 1m far according to ISO EN 3744. 4. Sound power level [Lw] according to ISO EN 9614 - 2 100 T 220 P3 T 240 P4 T 290 P3 T 300 P4 T 340 P4 T 380 P4 T 460 P6 T 570 P6 270 276 331 347 403 446 534 670 62,4 65 79,3 83,2 95 107 124 161 113 121 142 150 170 190 224 287 46,4 47,3 56,8 59,5 69,1 76,6 91,6 115 52 61 49 70 70 64 63 85 57,6 59 71,1 74,5 86,2 95,7 114 144 68 81 60 89 86 74 64 83 42,1 43 51,7 54,1 62,8 69,6 83,2 104 7,3 7,4 8,9 9,3 10,8 12 14,3 18 10,5 8,4 10 10,3 13,9 10,1 10,3 10,1 scroll scroll scroll scroll scroll scroll scroll scroll 3 4 3 4 4 4 6 6 197 246 194 262 295 328 393 492 441 584 418 507 597 630 637 794 3 4 3 4 4 4 6 6 1 1 1 1 1 1 1 1 20,7 27 20,3 27,5 33,8 44,6 44,6 57,2 65 66,2 79,5 83,3 96,7 107,2 128,2 161 1 1 1 1 1 1 1 1 22,5 23,9 30,6 29,3 33,8 41 51,8 56,3 80,6 82,6 99,5 104,3 120,7 134 159,6 201,6 1 2 1 2 2 2 2 2 6,3 2 x 2,1 8 2 x 4,0 2 x 4,0 2 x 5,3 2 x 6,3 2 x 8,0 10,2 10,4 12,5 13 15,1 16,8 20 25,2 R410A R410A R410A R410A R410A R410A R410A R410A 23,1 24,7 30,3 31,6 31,1 48,1 49,5 62,4 1 2 1 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,33 4,25 4,17 4,17 4,24 4,17 4,31 4,16 6,51 5,64 6,35 5,76 5,88 5,77 6,14 6,05 6,92 6 6,75 6,13 6,25 6,14 6,53 6,43 65,8 67 65,8 67 67 67 68,8 68,8 82,8 84,1 82,8 84,1 84,5 84,5 86,3 86,3 1800 1800 1800 1800 1800 1800 1800 1800 1200 1200 1200 1200 1800 1800 1800 1800 1740 1740 1740 1740 1740 1740 1740 1740 1302 1545 1403 1590 1665 1775 2270 2300 -- -- -- -- -- -- -- -- 88,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 2" 2 x 1 1/4" 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 101 Water Cooled Chiller | EWML RC 27 / 570 Cooling only Scroll Remote condenser R410A ❯❯Cooling Capacity from 23 to 670 KW ❯❯Size = 33 ❯❯Refrigerant : R410A ❯❯EER up to 4.40 ❯❯ESSEER up to 6.51 Main Functions: ❯❯Remote condenseur ❯❯Scroll compressors ❯❯Evaporator Heat plate exchanger Available Versions: ❯❯Mono ou Bo-circuit ❯❯Partial heat recovery available ❯❯Heat pump version reversible on refrigerant circuit Main accessories and options Code 118 119 172 175 178 450 451 605 919 923 926 931 Brine version kit A Brine version kit B Rubber support (kit) Victaulic Connections HR 100% Victaulic connections Desuperheater 100% Heat Reclaim Compr. Power factor capcitor 0,9 Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board 932 BACnet MS/TP serial board 942 Serial card for GSM Modem 943 Data Logger (see EWMH range) ❯❯Heat pump version reversible on Hydraulic circuit (see EWMH W range) ❯❯Remote condenseurheat pump (see EWMH RC range) ❯❯Brine version ❯❯Total 100% heat recovery Product Advantages ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED For general caracteristics, cf EWML data page 94, for performances see software selection program 102 103 Water Cooled Chiller | EWSL K 190 / 660 Energy Class More efficient A+ A B C D E Cooling only Screw Less efficient B F G ❯❯Cooling Capacity from 186 to 655 KW ❯❯Size = 13 ❯❯Refrigerant : R134 A ❯❯EER up to 4.76 ❯❯ESSEER up to 5.25 Main Functions: ❯❯CLASS B ❯❯MONO Screw compressor ❯❯Evaporator Heat plate exchanger ❯❯Condenser Heat plate exchanger ❯❯Linear Modulating control capacity 25…100 % Main accessories and options Available Versions: ❯❯Brine version Code 118 119 171 550 919 923 926 931 Brine version kit A Brine version kit B Rubber antivibration holders Stop valve on compressor suction line Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board 932 BACnet MS/TP serial board 942 Serial card for GSM Modem 943 Data Logger Product Advantages ❯❯Plug and play, robust and reliable ❯❯Leaving evaporator Temperature up to -12°C ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Input for air ambiant t° ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED ❯❯large operating range WORKING LIMITS - COOLING - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings. (°C) 20 Evaporator outlet temperature 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -10 -13 15 20 25 30 35 40 45 50 55 60 65 (°C) Condenser water outlet temperature 104 105 207 43,5 69,8 39,1 66 Compressors power input kW 134,8 495 1 117,8 351 50…100 1 102,5 280 50…100 Starting current A Maximum current A Quantity n. Twin screw Twin screw 1 88,9 88,9 88,9 88,9 88,9 88,9 1465 1790 600 2500 93,1 76 5,35 5,2 4,74 400/3/50 1 17 R134a 68 29 1 42 18 1 50…100 1 Twin screw 1. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C. 2. Sound pressure level [Lp] 1m far according to ISO EN 3744. 3. Sound power level [Lw] according to ISO EN 9614 - 2 Inlet/outlet – (OD) nxØ mm CONDENSER Inlet/outlet – (OD) nxØ mm EVAPORATOR 1790 1423 1790 1399 Height mm kg 2500 600 2500 600 Width mm 72 89,1 Length mm Sound power level [Lw] (3) dB(A) Sound pressure level [Lp] (2) dB(A) 71 5,4 5,23 IPLV - ARI Standard 550/590 88,1 4,76 5,25 4,76 5,09 ESEER - Eurovent Standard 400/3/50 1 V/Ph/Hz 400/3/50 Gas circuits n. R134a 16 R134a 15 27 63 25 58 Total water volume l Max water flow rate m³/h 37 1 32 1 Max water flow rate m³/h n. 1 16 1 14 n. Water volume l EER - Energy Efficiency Ratio kW/kW HYDRAULIC CONNECTIONS NET WEIGHT DIMENSIONS SOUND LEVEL 48,4 5 43,4 5 39 6 Stepless capacity control % ENERGY EFFICIENCY INDEXES POWER SUPPLY 39,6 20 Pressure drop kPa Pressure drop kPa 80,3 48,7 231 240.1 Water flow rate m³/h 35,5 22 31,9 18 Water flow rate m³/h Compressors operating current [OA] A 210.1 190.1 186 COOLING CAPACITY kW Total refrigerant charge (optional excluded) kg REFRIGERANT CONDENSER EVAPORATOR COMPRESSOR CONDENSER EVAPORATOR EWSL K MODEL 88,9 88,9 1476 1790 600 2500 93,1 76 5,21 5,07 4,76 400/3/50 1 17 R134a 68 29 1 47 20 1 50…100 495 144,1 1 Twin screw 5 52,2 18 42,7 90,4 52,3 249 250.1 88,9 88,9 1689 1790 600 2500 93,1 76 5,28 4,99 4,72 400/3/50 1 15 R134a 58 25 1 53 23 1 50…100 646 165,2 1 Twin screw 7 55,2 27 45,1 90,6 55,7 263 270.1 88,9 88,9 1733 1790 600 2500 96,1 79 5,39 5,1 4,71 400/3/50 1 16 R134a 63 27 1 68 29 1 50…100 361 183,4 1 Twin screw 7 63 31 52,5 109 65 306 310.1 2x88,9 2x88,9 1750 1790 700 2800 97,4 80 5,38 5,09 4,73 400/3/50 1 37 R134a 74 2x31 2 74 2x31 2 50…100 361 207 1 Twin screw 8 74 32 60,6 128 74,7 353 360.1 2x88,9 2x88,9 2117 1790 700 2800 97,4 80 5,36 5,07 4,72 400/3/50 1 42 R134a 84 2x36 2 84 2x36 2 50…100 374 237,1 1 Twin screw 8 84 33 70,3 139 86,8 410 410.1 2x88,9 2x88,9 2151 1790 700 2800 96,4 79 5,35 5 4,69 400/3/50 1 48 R134a 95 2x40 2 95 2x40 2 50…100 453 267,9 1 Twin screw 10 95 35 79,4 159 98,7 463 470.1 2x88,9 2x88,9 2177 1790 700 2800 98,4 81 5,44 5,04 4,63 400/3/50 1 53 R134a 105 2x45 2 95 2x40 2 50…100 543 283,7 1 Twin screw 11 103 32 84,2 167 106 491 500.1 2x88,9 2x88,9 2233 1790 700 2800 98,4 81 5,56 5,18 4,73 400/3/50 1 58 R134a 116 2x49 2 105 2x45 2 50…100 595 307,7 1 Twin screw 11 110 31 90,1 180 111 525 530.1 2x88,9 2x88,9 2616 1790 700 3100 99,6 82 5,56 5,17 4,71 400/3/50 1 64 R134a 126 2x54 2 126 2x54 2 50…100 703 354,8 1 Twin screw 9 122 28 99,3 201 123 579 580.1 2x88,9 2x88,9 2663 1790 700 3100 99,6 82 5,57 5,19 4,75 400/3/50 1 69 R134a 137 2x58 2 158 2x67 2 50…100 783 398,8 1 Twin screw 9 137 19 112 225 138 655 660.1 Water Cooled Chiller | EWSL A 410 / 1610 Energy Class classA More efficient A+ A B C D E Cooling only Screw Class A Less efficient F G ❯❯Cooling Capacity from 406 to 1604 KW ❯❯Size = 14 ❯❯Refrigerant : R134 A ❯❯EER up to 5.12 ❯❯ESSEER up to 5.72 Main Functions: ❯❯classA ❯❯Twin Screw compressors ❯❯Shell and tube evaporator high efficiency ❯❯Shell and tube condenser high efficiency ❯❯Linear Modulating control capacity 25…100 % ❯❯2 cooling circuits Main accessories and options Code 118 119 171 450 550 731 780 919 923 926 931 Available Versions: ❯❯Brine version ❯❯Partial heat recovery Brine version kit A Brine version kit B Rubber antivibration holders Desuperheater Stop valve on compressor suction line Safety water flow switch Noise absorption box Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board 932 BACnet MS/TP serial board 942 Serial card for GSM Modem 943 Data Logger Product Advantages ❯❯classA ❯❯2 cooling circuits ❯❯Plug and play, robust and reliable ❯❯Leaving evaporator Temperature up to -11°C ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Input for air ambiant t° ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED ❯❯large operating range WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings Evaporator outlet temperature (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -10 -13 15 20 25 30 35 40 45 50 55 (°C) Condenser water outlet temperature 106 107 Water volume Max water flow rate Quantity Maximum current Starting current Stepless capacity control 3359,5 975 1498 3268 168,3 2 x 3" -2 x 2" 74 91,8 3359,5 975 1498 3237 168,3 mm mm mm kg Ømm nxØ 2 x 3" n x Ømm -2 x 2" dB(A) dB(A) nxØ 74 91,8 5,08 5,34 5,42 5,06 5,41 5,72 kW/kW 2 x 2" 2 x 3" -- 168,3 3349,5 1013 1618 3498 74 91,8 5,08 5,68 5,77 65,9 11,3 3,7 twinscrew 2 219,6 460,8 25...100 1 255 127 2 99 116 2 19,2 37 R134a 155 2 400/3/50 105 16 87 19 507 99,9 162 510 2 x 2" 2 x 3" -- 168,3 3349,5 1013 1618 3590 79 96,8 5,09 5,72 6,04 70,2 12,1 3,5 twinscrew 2 238,4 614,2 25...100 1 255 127 2 99 116 2 19,2 37 R134a 155 2 400/3/50 112 1 92,6 21 540 106 181 540 1. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C. 2. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C and hot water temperature 40/45°C. Total water volume Max water flow rate PARTIAL HEAT RECOVERY EXCHANGERS Total water volume Max water flow rate REFRIGERANT Total refrigerant charge (optional excluded) Gas circuits POWER SUPPLY ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio ESEER - Eurovent Standard IPLV - ARI Standard 550/590 SOUND LEVEL Sound pressure level [Lp] (3) Sound power level [Lw] (4) DIMENSIONS Length Width Height NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet – (OD) CONDENSER Inlet/outlet – (ISO228/1) Inlet/outlet – (OD) PARTIAL HEAT RECOVERY Inlet/outlet – (ISO228/1) CONDENSER EVAPORATOR COMPRESSORS 94,9 13 59,5 10,3 4,2 twinscrew 2 194,4 377,2 25...100 1 142 100 2 78 98 2 14,4 37 R134a 65 2 400/3/50 84,6 10 78,6 18 458 90,2 142 408 80,6 134 70 12 460 410 53 9,1 4,6 twinscrew n. 2 A 185,8 A 354,9 25...100 n. 1 l 149 m³/h 95 n. 2 l 78 m³/h 98 n. 2 l 14,4 m³/h 37 R134a kg 65 n. 2 V/Ph/Hz 400/3/50 Water flow rate m³/h Pressure drop kPa Water flow rate m³/h Pressure drop kPa HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa PARTIAL HEAT RECOVERY (2) CONDENSER EVAPORATOR COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A COOLING ONLY (1) EWSL A MODEL 2 x 2" 2 x 3" -- 168,3 3435 1007 1740 3720 79 96,8 5,06 5,12 5,44 78,9 13,6 3,3 twinscrew 2 271,8 359,9 25...100 1 255 127 2 99 116 2 19,2 37 R134a 155 2 400/3/50 126 22 104 24 607 120 194 610 2 x 2" 2 x 3" -- 219,1 3894 1210 1888 4071 82 100,6 5,06 5,16 5,49 103 17,7 3,8 twinscrew 2 347,8 453,9 25...100 1 237 154 2 109 170 2 37 37 R134a 142 2 400/3/50 164 25 136 13 790 156 264 790 2 x 2" 2 x 3" -- 219,1 3894 1210 1888 4835 82 100,6 5,07 5,08 5,37 121 20,9 4,6 twinscrew 2 391,4 549,7 25...100 1 229 172 2 109 186 2 32 67 R134a 136 2 400/3/50 193 19 160 19 932 184 290 940 2 x 2" 2 x 3" -- 219,1 3894 1210 1888 4949 82 101,2 5,05 5,06 5,34 135 23,3 5,2 twinscrew 2 441,8 594,9 25...100 1 276 172 2 135 216 2 34 67 R134a 130 2 400/3/50 216 21 179 26 1041 206 326 1050 2 x 2" 2 x 3" -- 219,1 3932,5 1218 1890 5031 82 101,2 5,09 5,16 5,46 144 24,8 7,2 twinscrew 2 466,2 686,1 25...100 1 276 172 2 135 216 2 34 67 R134a 130 2 400/3/50 229 25 190 27 1105 217 340 1110 3. Sound pressure level [Lp] 1m far according to ISO EN 3744. 4. Sound power level [Lw] according to ISO EN 9614 - 2 2 x 2" 2 x 3" -- 168,3 3514 1060 1780 3967 79 97,6 5,12 5,19 5,51 91,1 15,7 3,4 twinscrew 2 310,8 435,4 25...100 1 255 127 2 99 116 2 27 37 R134a 155 2 400/3/50 145 21 120 16 701 137 230 700 2 x 2" -2 x 114,3 219,1 3874 1287 1975 5549 82 101,2 5,08 5,04 5,17 148 25,5 8,3 twinscrew 2 497,2 791,6 25...100 1 370 220 2 155 240 2 39 67 R134a 121 2 400/3/50 236 23 195 23 1139 224 359 1140 2 x 2" -2 x 114,3 219,1 4273 1284 2084 6407 84 103,6 5,09 5,04 5,18 170 29,2 10,9 twinscrew 2 569,6 835,8 25...100 1 368 245 2 171 260 2 39 67 R134a 180 2 400/3/50 270 19 224 28 1304 256 415 1310 2 x 2" -2 x 114,3 273 4273 1284 2084 6537 84 103,6 5,08 5,1 5,24 189 32,5 13,5 twinscrew 2 640,6 1023,3 25...100 1 357 267 2 182 284 2 54 67 R134a 176 2 400/3/50 301 19 249 36 1453 286 455 1460 2 x 2" -2 x 141,3 273 4352 1284 2108 6814 84 103,6 5,06 4,99 5,12 209 35,9 16,5 twinscrew 2 713,6 1147,8 25...100 1 431 312 2 210 320 2 54 67 R134a 172 2 400/3/50 333 22 275 45 1604 317 504 1610 Water Cooled Chiller | EWSL A+ 620 / 1180 Class Énergie Économe A+ A B C D E Cooling only Screw Class A+ Peu économe A+ classA+ F G ❯❯Cooling Capacity from 620 to 1160 KW ❯❯Size = 7 ❯❯Refrigerant : R134 A ❯❯EER up to 5.61 ❯❯ESSEER up to 6.55 Main Functions: ❯❯classA+ ❯❯Twin Screw compressors ❯❯Shell and tube evaporator high efficiency ❯❯Shell and tube condenser high efficiency ❯❯Linear Modulating control capacity 25…100 % ❯❯2 cooling circuits Main accessories and options Code 118 119 171 450 550 731 780 919 923 926 931 Available Versions: ❯❯Brine version ❯❯Partial heat recovery Brine version kit A Brine version kit B Rubber antivibration holders Desuperheater Stop valve on compressor suction line Safety water flow switch Noise absorption box Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board 932 BACnet MS/TP serial board 942 Serial card for GSM Modem 943 Data Logger Product Advantages ❯❯classA+ ❯❯High level of energy efficiency ❯❯Plug and play, robust and reliable ❯❯Leaving evaporator Temperature up to -11°C ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Input for air ambiant t° ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED ❯❯Large operating range WORKING LIMITS - COOLING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software (°C) 20 Evaporator outlet temperature 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -10 -13 15 20 25 30 35 40 45 50 55 (°C) Condenser water outlet temperature 108 EWSL A+ MODEL 620 720 820 970 1080 1150 1180 COOLING CAPACITY kW 623 717 813 961 1064 1123 1160 Compressors power input kW 111 131 147 175 197 208 214 179 218 251 277 317 328 347 Water flow rate m³/h 107 123 140 165 183 193 199 Pressure drop kPa 11 16 25 15 20 22 25 Water flow rate m³/h 127 147 166 197 218 230 238 Pressure drop kPa 22 4 40 55 8 5 4 81,1 93,2 106 125 138 146 151 14 16 18,2 21,5 23,8 25,1 26 3,4 3,5 4 4,9 5,4 7,4 8,6 twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew 2 2 2 2 2 2 2 Maximum current A 272 311 348 391 442 466 497 Starting current A 360 435 454 550 595 686 792 25 ...100 25 ...100 25 ...100 25 ...100 25 ...100 25 ...100 25 ...100 1 1 1 1 1 1 1 382 359 348 425 625 724 724 208 241 265 385 407 440 440 2 2 2 2 2 2 2 267 213 297 342 297 342 366 204 204 252 326 326 362 362 2 2 2 2 2 2 2 19,2 27 37 32 34 34 39 37 37 37 67 67 67 67 R134a R134a R134a R134a R134a R134a R134a 171 171 156 216 216 211 211 2 2 2 2 2 2 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 COOLING ONLY (1) Compressors operating current [OA] A EVAPORATOR CONDENSER PARTIAL HEAT RECOVERY (2) HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa COMPRESSORS Quantity n. Stepless capacity control % EVAPORATOR n. Water volume l Max water flow rate m³/h CONDENSER n. Total water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Total water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY V/Ph/Hz ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio kW/kW 5,61 5,47 5,53 5,49 5,4 5,4 5,42 ESEER - Eurovent Standard 6,14 6,18 6,16 6,1 6,13 6,18 5,98 IPLV - ARI Standard 550/590 6,55 6,53 6,54 6,46 6,45 6,52 6,2 Sound pressure level [Lp] (3) dB(A) 79 79 82 82 82 82 82 96,8 96,8 97,6 97,6 97,6 98,2 98,2 Length mm 3514 3514 3982 3818 3818 3818 3818 Width mm 1060 1060 1057,5 1269 1269 1269 1269 Height mm 1770 1770 1770 1991 1991 1991 1991 kg 4009 4051 4325 5439 5459 5565 5649 168,3 219,1 219,1 219,1 219,1 219,1 273 3" 3" 3" -- -- -- -- -- -- -- 114,3 114,3 114,3 114,3 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" SOUND LEVEL Sound power level [Lw] (4) dB(A) DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet – (OD) Ømm CONDENSER Inlet/outlet – (ISO228/1) Ø Inlet/outlet – (OD) Ømm PARTIAL HEAT RECOVERY Inlet/outlet – (ISO228/1) n x Ø 1. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C. 2. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C and hot water temperature 40/45°C. 3. Sound pressure level [Lp] 1m far according to ISO EN 3744. 4. Sound power level [Lw] according to ISO EN 9614 - 2 109 Water Cooled Chiller | EWNH 06 / 30 Heat pump Scroll R410A ❯❯Cooling Capacity from 5 to 30 KW ❯❯Heating capacity from 7 up to 37 KW ❯❯Size = 13 ❯❯Refrigerant : R410A ❯❯EER up to 4.81 ❯❯ESSEER up to 6.68 ❯❯COP up to 4.44 Main Functions: ❯❯Heat pump (reversible on the refrigerant circuit) ❯❯Solution for domestic and small offices installation ❯❯Scroll compressor ❯❯Evaporator Heat plate exchanger ❯❯Condenser Heat plate exchanger Main accessories and options Code 450 610 920 923 1002 Available Versions: ❯❯One phase up to the 13 KW ❯❯3 phases on the full range ❯❯Cooling only (see EWNL range) ❯❯Remote condenseur cooling only (see EWNL RC range) ❯❯Remote condenseurheat pump (see EWNH RC range) Product Advantages ❯❯Simple and reliable ❯❯Plug and play ❯❯Microprocessor control ❯❯3 speed circulating pump as STD (evap) ❯❯Signal 0 10 V for 2 ways valve management on condenseur side ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED WORKING LIMITS - COOLING - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software (°C) 20 Evaporator outlet temperature 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit -5 -10 -13 20 25 30 35 40 45 50 55 60(°C) Condenser water outlet temperature 110 Desuperheater Noise deading cup on compresseur Remote control kit COM MBUS/JBUS serial board Condensing control with 2 way valve 111 0,96 37 1,2 54 7,6 1,9 3,4 0,96 29 0,98 31 0,9 0,2 0,3 scroll 1 12,8 60 1 1 0,5 1,6 1 0,5 1,2 1 0,1 0,3 R410A 0,7 1 230/1/50 m³/h kPa m³/h kPa kW kW A m³/h kPa m³/h kPa kW m³/h kPa 3,95 4,09 4,78 6,39 42 56,2 555 650 900 90,8 1 1/2" 1" Kw/Kw Kw/Kw dB(A) dB(A) mm mm mm kg Ø Ø kg n. V/Ph/Hz n. A A n. n. l m³/h n. l m³/h n. l m³/h 5,6 1,4 2,8 kW kW A 06M 1" 1 1/2" 555 650 900 93,5 42 56,2 4,23 4,11 6,23 6,62 1,1 0,2 0,4 scroll 1 17,1 67 1 1 0,7 2,2 1 0,7 1,6 1 0,1 0,5 R410A 0,9 1 230/1/50 1,24 28 1,3 30 9,5 2,3 4,3 1,6 48 1,3 33 7,6 1,8 3,6 08M 1" 1 1/2" 555 650 900 103,6 44 58,2 4,53 4,3 5,19 6,68 1,6 0,3 0,8 scroll 1 21 98 1 1 0,9 2,9 1 0,9 2,1 1 0,1 0,6 R410A 1,1 1 230/1/50 1,73 32 1,8 34 13,1 3,1 5,2 2,1 49 1,8 38 10,5 2,3 4,1 10M 1" 1 1/2" 555 650 900 108,4 44 58,2 4,41 4,44 5,46 6,95 2,1 0,4 1,3 scroll 1 31 115,5 1 1 1,1 3,7 1 1,1 2,8 1 0,1 0,8 R410A 1,4 1 230/1/50 2,3 35 2,23 33 17,2 3,9 6,4 2,76 59 2,23 42 13 3 5,1 13M 1" 1 1/2" 555 650 900 90,8 42 56,2 3,76 3,9 4,6 6,65 0,9 0,2 0,2 scroll 1 4,7 28 1 1 0,5 1,6 1 0,5 1,1 1 0,1 0,3 R410A 0,7 1 400/3/50+N 0,92 27 0,91 26 7,2 1,9 3,4 1,1 45 0,91 33 5,3 1,4 2,8 06T 1. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Referred to chilled water temperature 12/7°C; hot water outlet temperature 45°C. 3. Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. COOLING CAPACITY Compressor power input Compressor operating current [OA] PLANT SIDE HEAT EXCHANGER Water flow rate Pressure drop EXHAUSTION SIDE HEAT EXCHANGER Water flow Pressure drops WINTER WORKING MODE (2) HEATING CAPACITY Compressor power input Compressor operating current [OA] PLANT SIDE HEAT EXCHANGER Water flow rate Pressure drop EXHAUSTION SIDE HEAT EXCHANGER Water flow Pressure drops PARTIAL HEAT RECOVERY (3) HEATING CAPACITY Water flow rate Pressure drop COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT SIDE HEAT EXCHANGER Water volume Max water flow rate EXHAUSTION SIDE HEAT EXCHANGER Water volume Max water flow rate PARTIAL HEAT RECOVERY EXCHANGER Water volume Max water flow rate REFRIGERANT Total refrigerant charge (optional excluded) Gas circuit POWER SUPPLY ENERGY EFFIFICIENCY INDEXES EER – Energy Efficiency Ratio COP – Coefficient of Performance ESEER – Eurovent Standard IPLV – ARI Standard 550/590 SOUND LEVEL Sound pressure level [Lp] (4) Sound power level [Lw] (5) DIMENSIONS Length Width Height NET WEIGHT HYDRAULIC CONNECTIONS PLANT / EXHAUSTION HEAT EXCHANGERS Inlet / outlet – ISO228/1-G M PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M SUMMER WORKING MODE (1) EWNH MODEL 2,39 27 2,43 29 2,2 0,4 0,4 scroll 1 11,8 64 1 1,2 4 1,2 3 0,2 0,9 R410A 1,5 1 400/3/50+N 4,02 4,26 5,28 6,78 47 61,2 555 650 900 116,6 1 1/2" 1" 2,12 29 2,18 31 2 0,3 1,2 scroll 1 10,3 51,5 1 1,1 3,6 1,1 2,6 0,1 0,8 R410A 1,4 1 400/3/50+N 4,18 4,3 6,49 6,9 44 58,2 555 650 900 108,4 1 1/2" 1" 1,5 0,3 0,7 scroll 1 8 43 1 0,9 2,7 0,9 2 0,1 0,6 R410A 1,1 1 400/3/50+N 1,1 0,2 0,4 scroll 1 6,5 38 1 1 0,7 2,1 1 0,7 1,6 0,1 0,4 R410A 0,9 1 400/3/50+N 1” 1” 1 1 1 1 1 1" 1 1/2" 555 650 900 118,1 51 65,2 4,15 4,23 5,38 6,94 0,2 1 R410A 1,8 1 400/3/50+N 1 1,3 3,5 1 1,3 4,7 2,6 0,5 0,6 scroll 1 15 75 1 2,87 33 2,85 32 21,8 5,2 8,9 3,5 56 2,85 40 16,6 4 7,4 17T 1 1" 1 1/2" 555 650 900 120,6 48 62,2 4,12 4,24 5,28 6,8 0,2 1,2 R410A 1,8 1 400/3/50+N 1 1,6 3,9 1 1,6 5,3 3 0,5 0,7 scroll 1 15 101 1 3,24 31 3,19 29 24,7 5,8 10,8 3,9 50 3,19 37 18,6 4,5 9,3 20T 4. Sound pressure level [Lp] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 1 1/2" 555 650 900 103,6 44 58,2 4,08 4,19 6,62 7,04 1 1 1 1,66 28 1,63 27 1 1/2" 555 650 900 93,5 42 56,2 3,78 3,92 4,86 6,81 1 1,18 25 1,16 23 12,7 3 5,1 1 18,5 4,3 7,8 16,5 3,8 6,4 9,2 2,4 4,3 1 3 51 2 47 1,63 34 2,6 53 1,48 45 1,16 30 2,39 35 15T 2,12 38 13T 13,9 3,5 6,4 9,5 2,3 4,1 10T 12,3 2,9 5,1 6,8 1,8 3,6 08T 1 1" 1 1/2" 555 650 900 143,8 50 64,2 4,18 4,34 6,47 6,88 0,2 1,5 R410A 2,5 1 400/3/50+N 1 2 5 1 2 6,7 3,7 0,6 1,1 scroll 1 21 111 1 4,09 34 4,02 30 30,8 7,1 13,1 5 53 4,02 40 23,4 5,6 11,3 25T 1 1” 1 1/2" 555 650 900 149,5 50 64,2 4,81 4,37 6,68 7,1 0,2 1,7 R410A 3,1 1 400/3/50+N 1 2,4 5,8 1 2,4 7,8 4,7 0,8 1,8 scroll 1 22 118 1 4,95 35 5,16 34 37,4 8,6 16 5,8 40 5,16 41 30 6,2 12,5 30T Water Cooled Chiller | EWNH RC 06 / 30 Heat pump Scroll Remote condenseur R410A ❯❯Cooling Capacity from 5 to 30 KW ❯❯Heating capacity from 7 up to 37 KW ❯❯Size = 13 ❯❯Refrigerant : R410A ❯❯EER up to 4.84 ❯❯ESSEER up to 6.68 ❯❯COP up to 4.44 Main Functions: ❯❯Heat pump (reversible on the refrigerant circuit) ❯❯Remote condenseur ❯❯Solution for domestic and small offices installation ❯❯Scroll compressor ❯❯Evaporator Heat plate exchanger Main accessories and options Code 450 610 920 923 Available Versions: ❯❯One phase up to the 13 KW ❯❯3 phases on the full range ❯❯Heat pump version (see EWNH range) ❯❯Cooling only (see EWNL range) ❯❯Remote condenseur heat pump Desuperheater Noise deading cup on compresseur Remote control kit COM MBUS/JBUS serial board (see EWNH RC range) ❯❯Remote condenseur cooling only (see EWNL range) Product Advantages ❯❯Simple and reliable ❯❯Plug and play ❯❯Microprocessor control ❯❯3 speed circulating pump as STD (evap) For general caracteristics, cf EWNH data page 108, for performances see software selection program 112 113 Water Cooled Chiller | EWMH 27 / 570 Heat pump Scroll R410A ❯❯Cooling Capacity from 23 to 670 KW ❯❯Heating capacity from 27 to 828 KW ❯❯Size = 33 ❯❯Refrigerant : R410A ❯❯EER up to 4.29 ❯❯ESSEER up to 6.63 ❯❯COP up to 4.35 Main Functions: ❯❯Heat pump (reversible on the refrigerant circuit) ❯❯Scroll compressors ❯❯Evaporator Heat plate exchanger ❯❯Condenser Heat plate exchanger Main accessories and options Code 118 119 172 175 450 605 919 923 926 931 Available Versions: ❯❯Mono ou Bo-circuit ❯❯Partial heat recovery available ❯❯Cooling only (see EWML range) ❯❯Remote condenseur cooling only (see EWML RC range) ❯❯Remote condenseur heat pump (see EWMH RC range) ❯❯Brine version ❯❯Heat pump reversible on water circuit (see EWMH W range) 932 942 943 1002 Product Advantages ❯❯Plug and play ❯❯Leaving condenseur Temperature up to 60°C ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Signal 0 10 V for 2 ways valve management on condenseur side ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED WORKING LIMITS - COOLING - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software Evaporator outlet temperature (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit -5 -10 -13 20 25 30 35 40 45 50 55 60(°C) Condenser water outlet temperature 114 Brine version kit A Brine version kit B Rubber support (kit) Victaulic Connections Desuperheater Compr. Power factor capcitor 0,9 Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board Serial card for GSM Modem Data Logger Condensing control with 2 way valve EWMH MODEL 27.1 30.1 33.1 39.1 40.1 40.2 48.1 26,8 6,3 12,6 30,3 7,1 13,5 33,7 8,1 15,6 37,4 10 20,5 42,3 11,3 22,4 43,8 11,3 22,5 51,7 13,1 25,9 Water flow rate m³/h Pressure drop kPa 4,6 55 5,2 56 5,8 50 6,4 37 7,3 46 7,5 28 8,9 47 Water flow rate m³/h Pressure drop kPa 5,7 69 6,5 63 7,2 64 8,2 47 9,3 57 9,5 38 11,2 57 34,8 8,1 15 39,3 9 16,1 43,8 10,3 18,5 50,2 12,5 23,5 57,6 14,3 26,4 59,2 14,4 26,5 69,3 16,8 30,9 Water flow rate m³/h Pressure drop kPa 4,6 42 5,2 42 5,8 37 6,4 25 7,3 30 7,5 20 8,9 31 Water flow rate m³/h Pressure drop kPa 4,6 47 5,2 48 5,8 42 6,5 31 7,5 38 7,7 22 9 38 HEATING CAPACITY kW Water flow rate m³/h Pressure drop kPa 4,2 0,7 6,1 4,7 0,8 7,9 5,2 0,9 9,6 5,9 1 4,1 6,8 1,2 5,4 ---- 8,2 1,4 8 scroll scroll scroll scroll scroll scroll scroll 1 22 118 1 1 25 118 1 1 31 140 1 1 34 173 1 2 42 132 2 2 42 132 2 2 44 140 2 1 1 1 1 1 1 1 2,8 6,4 2,8 7,3 2,8 8,1 3,1 9 3,1 10,2 3,6 10,5 3,1 12,4 1 1 1 1 1 1 1 2,8 8 2,8 9,1 2,8 10,1 3,1 11,5 3,1 13 3,6 13,4 3,1 15,7 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PLANT WATER EXCHANGER EXHAUST WATER EXCHANGER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PLANT WATER EXCHANGER EXHAUST WATER EXCHANGER PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h EXHAUST WATER EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY ENERGY EFFIFICIENCY INDEXES V/Ph/Hz EER – Energy Efficiency Ratio kW/kW COP – Coefficient of Performance kW/kW ESEER - Eurovent Standard IPLV - ARI 550/590 1 1 1 1 1 -- 1 0,4 1 0,4 1,1 0,4 1,3 0,6 1,4 0,6 1,6 --- 0,6 2 R410A R410A R410A R410A R410A R410A R410A 2,9 1 2,9 1 3 1 3,9 1 4,2 1 5 2 4,3 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,24 4,31 5,87 6,24 4,27 4,35 5,84 6,21 4,17 4,25 5,86 6,23 3,76 4,02 6,02 6,4 3,74 4,03 5,2 5,52 3,88 4,11 6,14 6,53 3,95 4,13 5,46 5,8 50 65,4 51 66,4 52 67,4 53 68,8 53 68,9 53 68,9 53 68,9 1000 650 1400 1000 650 1400 1000 650 1400 1000 650 1400 1200 750 1700 1200 750 1700 1200 750 1700 263 266 275 288 445 455 455 1 1/2" -1" 1 1/2" -1" 1 1/2" -1" 2" -1" 2" -1" 2" --- 2" -1" SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg PLANT/EXHAUST EXCHANGER Inlet / outlet – ISO228/1-G M Ø PARTIAL HEAT RECOVERY Ø mm Inlet / outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/ 35°C. 2. Gross value - Referred to hot water outlet temperature at 45°C and chilled water temperature 15/10°C 3. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 115 ➜ Heat pump - EWMH 27 / 570 | EWMH MODEL 48.2 54.1 54.2 60.1 60.2 70.1 70.2 50,5 12,7 25,5 56,9 14,9 27,8 57,3 14,5 27,2 62,5 16,5 31,8 63,7 16,2 31,2 84,7 20,1 41,1 74,8 19,6 40,6 Water flow rate m³/h Pressure drop kPa 8,7 29 9,8 50 9,8 28 10,7 43 10,9 28 14,5 50 12,8 28 Water flow rate m³/h Pressure drop kPa 11 38 12,4 60 12,4 37 13,7 51 13,8 36 18,2 60 16,4 37 68 16,4 30,4 76,4 19,1 33,7 76,6 18,6 32,9 84 21,1 37,9 84,6 20,6 37,3 101 25,1 47,1 101 24,8 46,7 Water flow rate m³/h Pressure drop kPa 8,7 20 9,8 32 9,8 20 10,7 27 10,9 20 14,5 40 12,8 19 Water flow rate m³/h Pressure drop kPa 8,9 23 9,9 40 10 22 10,8 35 11 22 13,1 41 13,1 23 ---- 8,9 1,5 6,2 ---- 9,8 1,7 7,4 ---- 11,9 2 6,4 ---- scroll scroll scroll scroll scroll scroll scroll 2 44 140 2 2 50 143 2 2 50 143 2 2 62 171 2 2 62 171 2 2 68 207 2 2 68 207 2 1 1 1 1 1 1 1 4,2 12,1 3,9 13,7 4,2 13,8 3,9 15 4,2 15,3 4,7 20,3 6,4 17,9 1 1 1 1 1 1 1 4,2 15,4 3,9 17,4 4,2 17,4 3,9 19,2 4,2 19,3 4,7 25,5 6,4 23 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PLANT WATER EXCHANGER EXHAUST WATER EXCHANGER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PLANT WATER EXCHANGER EXHAUST WATER EXCHANGER PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Water flow rate m³/h Pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h EXHAUST WATER EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY ENERGY EFFIFICIENCY INDEXES V/Ph/Hz EER – Energy Efficiency Ratio kW/kW COP – Coefficient of Performance kW/kW ESEER - Eurovent Standard IPLV - ARI 550/590 -- 1 -- 1 -- 1 -- --- 0,8 2,2 --- 0,8 2,4 --- 1 2,9 --- R410A R410A R410A R410A R410A R410A R410A 5,7 2 5,7 1 5,7 2 5,8 1 5,7 2 6,6 1 8,1 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,98 4,15 6,43 6,84 3,82 4 5,38 5,72 3,95 4,12 6,15 6,54 3,79 3,98 5,09 5,41 3,93 4,11 5,79 6,15 4,21 4,02 5,45 5,79 3,82 4,07 6,3 6,7 53 68,9 54 69,9 54 69,9 55 70,9 55 70,9 56 71,9 56 71,9 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 470 465 480 470 495 475 506 2" --- 2" -1" 2" --- 2" -1" 2" --- 2" -1" 2" --- SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg PLANT/EXHAUST EXCHANGER Inlet / outlet – ISO228/1-G M Ø PARTIAL HEAT RECOVERY Ø mm Inlet / outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/ 35°C. 2. Gross value - Referred to hot water outlet temperature at 45°C and chilled water temperature 15/10°C 3. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 116 90.1 90.2 120.1 120.2 150.1 150.2 170.2 190.2 200.1 200.2 220.1 220.2 96,9 25,7 47,5 98,2 25,1 46,7 122 32,6 60 119 31,9 59,3 158 41,5 74,1 154 40,8 73,6 194 45,4 88 206 53,3 94 207 52,4 93,7 220 52,3 93,6 262 61,1 110 250 63,9 119 16,6 46 16,8 29 20,9 48 20,5 38 27 46 26,4 42 33,3 43 35,4 34 35,6 46 37,7 53 45 52 42,9 61 21,2 52 21,3 36 26,7 53 26,2 47 34,5 45 33,8 47 41,5 69 45 42 45 62 47,1 71 55,9 68 54,3 81 132 32,5 55,6 132 31,7 54,5 165 40,9 69,3 164 40,3 68,5 213 52 87,8 211 51,6 87,3 237 58,1 105 262 69,7 113 275 64,7 110 276 64,2 109 332 76,8 130 335 80,4 137 16,6 27 16,8 19 20,9 28 20,5 24 27 24 26,4 24 33,3 58 35,4 76 35,6 37 37,7 43 45 46 42,9 44 17,1 37 17,3 23 21,4 39 21,2 31 27,8 38 27,4 33 30,9 45 33,2 28 36,2 43 36,4 44 43,9 49 43,8 50 15,5 2,7 6,3 ---- 19,4 3,3 6,9 ---- 25,2 4,3 8,9 24,9 4,3 7 28 4,8 8,9 30,1 5,2 6 32,9 5,7 9 33 5,7 7,2 39,8 6,9 9,4 39,7 6,8 7,2 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 2 80 265 2 2 80 265 2 2 97 321 2 2 97 321 2 2 131 375 2 2 131 375 2 4 148 333 4 4 160 345 4 2 164 466 2 2 164 466 2 3 197 441 3 4 246 584 4 1 1 1 1 1 1 1 1 1 1 1 1 5,8 23,2 6,7 23,5 7,2 29,3 8,3 28,7 8,7 37,8 12,3 37 12,3 46,6 20,3 49,6 20,7 49,8 20,3 52,8 20,7 63 20,3 60,1 1 1 1 1 1 1 1 1 1 1 1 1 5,8 29,7 6,7 29,8 7,2 37,4 8,3 36,7 8,7 48,3 12,3 47,3 12,3 58,1 20,3 63 20,7 63 20,3 65,9 20,7 78,3 20,3 76 1 -- 1 -- 1 2 2 2 1 2 1 2 1,7 3,7 --- 2,1 4,7 --- 4 6,1 2 6 3,4 6,7 3,4 7,3 5,3 7,9 3,4 8 6,3 9,6 4,2 9,6 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 8,7 1 10,4 2 10,7 1 12,7 2 12,4 1 17 2 17,8 2 23,9 2 22,4 1 22,8 2 23,1 1 24,7 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 3,77 4,06 5,2 5,52 3,91 4,16 5,96 6,34 3,74 4,03 5,13 5,46 3,73 4,07 5,99 6,37 3,81 4,1 5,1 5,42 3,77 4,09 6 6,38 4,27 4,08 5,46 5,62 3,86 3,76 6,63 6,43 3,95 4,25 5,17 5,5 4,21 4,3 6,01 6,39 4,29 4,32 6,37 6,77 3,91 4,17 5,53 5,87 61 76,9 61 76,9 64 80,1 64 80,1 64 81 64 81 64 81 64 81 64 81 64 81 65,8 82,8 67 84,1 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 730 770 785 800 1035 1040 1140 1345 1100 1135 1310 1570 -73,1 1 1/4" -73,1 -- -73,1 1 1/4" -73,1 -- -73,1 2" -73,1 2 x 1" -73,1 2 x 1 1/4" -88,9 2 x 1 1/4" -88,9 2" -88,9 2 x 1 1/4" -88,9 2" -88,9 2 x 1 1/4" ➜ 117 Heat pump - EWMH 27 / 570 | EWMH MODEL 290.1 300.2 340.2 380.2 460.2 570.2 328 78,3 140 313 81,8 147 364 93,4 168 405 104 187 482 121 219 606 158 282 Water flow rate m³/h Pressure drop kPa 56,3 49 53,7 70 62,6 70 69,5 64 82,7 63 104 85 Water flow rate m³/h Pressure drop kPa 70,3 60 68,4 89 79,3 86 88,2 74 105 64 132 83 413 96,4 164 420 103 175 488 116 197 539 129 220 646 130 260 817 196 333 Water flow rate m³/h Pressure drop kPa 56,3 40 53,7 48 62,6 46 69,5 40 82,7 34 104 44 Water flow rate m³/h Pressure drop kPa 54,5 46 54,6 57 63,9 57 70,5 53 88,9 52 107 69 HEATING CAPACITY kW Water flow rate m³/h Pressure drop kPa 49,4 8,5 9,1 49,5 8,5 8,6 57,9 10 11,8 63,9 11 8,5 80,6 13,9 9,6 96,9 16,7 8,7 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PLANT WATER EXCHANGER EXHAUST WATER EXCHANGER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A PLANT WATER EXCHANGER EXHAUST WATER EXCHANGER PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps PLANT WATER EXCHANGER n. A A n. n. Water volume l Max water flow rate m³/h EXHAUST WATER EXCHANGER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT scroll scroll scroll scroll scroll 4 262 507 4 4 295 597 4 4 328 630 4 6 393 637 6 6 492 794 6 1 1 1 1 1 1 27 78,8 27,5 75,2 33,8 87,6 44,6 97,3 44,6 115,8 57,2 145,6 1 1 1 1 1 1 27 98,4 27,5 95,8 33,8 111 44,6 123,5 44,6 147 57,2 184,8 1 2 2 2 2 2 8 11,9 8 11,9 8 14 10,6 15,4 12,6 19,5 16 23,4 R410A R410A R410A R410A R410A R410A 30,3 1 31,6 2 31,1 2 48,1 2 49,5 2 62,4 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,19 4,28 6,23 6,62 3,83 4,08 5,65 6,01 3,9 4,21 5,75 6,12 3,89 4,18 5,66 6,02 3,98 4,97 6 6,38 3,84 4,17 5,93 6,31 65,8 82,8 67 84,1 67 84,5 67 84,5 68,8 86,3 68,8 86,3 Length mm Width mm Height mm 1800 1200 1740 1800 1200 1740 1800 1800 1740 1800 1800 1740 1800 1800 1740 1800 1800 1740 kg 1390 1615 1710 1796 2270 2365 -88,9 2" -88,9 2 x 2" -88,9 2 x 2" -88,9 2 x 2" -88,9 2 x 2" -88,9 2 x 2" Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY ENERGY EFFIFICIENCY INDEXES scroll 3 194 418 3 V/Ph/Hz EER – Energy Efficiency Ratio kW/kW COP – Coefficient of Performance kW/kW ESEER - Eurovent Standard IPLV - ARI 550/590 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS PLANT/EXHAUST EXCHANGER Inlet / outlet – ISO228/1-G M Ø PARTIAL HEAT RECOVERY Ø mm Inlet / outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/ 35°C. 2. Gross value - Referred to hot water outlet temperature at 45°C and chilled water temperature 15/10°C 3. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 118 119 Water Cooled Chiller | EWMH RC 27 / 380 Heat pump Scroll Remote condenseur R410A ❯❯Cooling Capacity from 23 to 670 KW ❯❯Heating capacity from 27 to 828 KW ❯❯Size = 28 ❯❯Refrigerant : R410A ❯❯EER up to 4.29 ❯❯ESSEER up to 6.63 ❯❯COP up to 4.35 Main Functions: ❯❯Heat pump (reversible on the refrigerant circuit) ❯❯Remote condenseur ❯❯Scroll compressor ❯❯Evaporator Heat plate exchanger Main accessories and options Code 118 Kit A fonctionnement basse température sortie eau glacée 119 Kit B fonctionnement basse température sortie eau glacée 172 Support caoutchoucs 174 EVP Victaulic connections 450 Desurchauffeur 605 Batterie de condensateurs pour cos phi 0,9 sur moteur compresseurs 919 Carte horloge 923 COM MBUS/JBUS carte série 926 LON carte série 931 BACnet Ethernet - SNMP - TCP/IP carte série 932 BACnet MS/TP carte série 942 Carte série pour modem GSM 943 Data logger Available Versions: ❯❯Mono ou Bi-circuit ❯❯Partial heat recovery available ❯❯Cooling only (see EWML range) ❯❯Remote condenseur cooling only (see EWML RC range) ❯❯Heat pump (see EWMH range) ❯❯Brine version ❯❯Heat pump reversible on water circuit (see EWMH W range) Product Advantages ❯❯Remote condenseur ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED For general caracteristics, cf EWMH data page 112, for performances see software selection program 120 121 Water Cooled Chiller | EWMH W 27 / 570 Heat pump on water side Scroll R410A ❯❯Cooling Capacity from 28 to 655 KW ❯❯Heating capacity from 35 to 828 KW ❯❯Size = 33 ❯❯Refrigerant : R410A ❯❯EER up to 4.44 ❯❯ESSEER up to 6.56 ❯❯COP up to 4.60 Main Functions: ❯❯Heat pump (reversible on the Hydraulic circuit) ❯❯Scroll compressors ❯❯Evaporator Heat plate exchanger ❯❯Condenser Heat plate exchanger Main accessories and options Code 118 119 172 220 450 605 919 923 926 931 Available Versions: ❯❯Mono ou Bo-circuit ❯❯Partial heat recovery available ❯❯Cooling only (see EWML range) ❯❯Remote condenseur cooling only (see EWML RC range) ❯❯Remote condenseur heat pump (see EWMH RC range) ❯❯Brine version ❯❯Heat pump on refrigerant circuit (see EWMH range ) 932 942 943 1002 Product Advantages ❯❯Plug and play ❯❯Leaving condenseur Temperature up to 60°C ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Signal 0 10 V for 2 ways valve management on condenseur side ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED WORKING LIMITS - COOLING - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software Evaporator outlet temperature (°C) 20 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit -5 -10 -13 20 25 30 35 40 45 50 55 60(°C) Condenser water outlet temperature 122 Brine version kit A Brine version kit B Rubber support (kit) Electronic expansion valve Desuperheater Compr. Power factor capcitor 0,9 Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board BACnet MS/TP serial board Serial card for GSM Modem Data Logger Condensing control with 2 way valve EWMH W MODEL 27.1 30.1 33.1 39.1 40.1 40.2 48.1 28 6,3 12,7 31,7 7,1 13,6 35,7 8,3 16 40,3 10 20,6 47 11,4 22,7 46,8 11,2 22,4 55,4 13,1 25,9 Water flow rate m³/h Pressure drop kPa 4,8 55 5,5 56 6,1 51 6,9 37 8,1 46 8 28 9,5 47 Water flow rate m³/h Pressure drop kPa 5,9 69 6,7 63 7,6 65 8,7 47 10,1 57 10,1 38 11,9 57 35,1 8,1 15,2 39,6 9,1 16,3 44,8 10,5 19,1 51,3 12,6 24,1 59,8 14,6 27 59,5 14,2 26,5 69,9 16,9 31,2 Water flow rate m³/h Pressure drop kPa 4,6 52 5,3 53 5,9 48 6,7 35 7,8 43 7,8 26 9,1 44 Water flow rate m³/h Pressure drop kPa 4,8 49 5,5 49 6,1 43 6,9 30 8,1 37 8 25 9,5 38 HEATING CAPACITY kW Water flow rate m³/h Pressure drop kPa 4,2 0,7 6,2 4,8 0,8 8 5,4 0,9 10,1 6 1 4,3 7,1 1,2 5,9 ---- 8,3 1,4 8,1 scroll scroll scroll scroll scroll scroll scroll 1 22 118 1 1 25 118 1 1 31 140 1 1 34 173 1 2 42 132 2 2 42 132 2 2 44 140 2 1 1 1 1 1 1 1 2,8 6,7 2,8 7,6 2,8 8,6 3,1 9,7 3,1 11,3 3,6 11,3 3,1 13,3 1 1 1 1 1 1 1 2,8 8,3 2,8 9,4 2,8 10,7 3,1 12,2 3,1 14,1 3,6 14,1 3,1 16,7 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Water volume l Max water flow rate m³/h CONDENSER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY ENERGY EFFIFICIENCY INDEXES V/Ph/Hz EER – Energy Efficiency Ratio kW/kW COP – Coefficient of Performance kW/kW ESEER - Eurovent Standard IPLV - ARI 550/590 1 1 1 1 1 -- 1 0,4 0,6 0,4 0,7 0,4 0,8 0,6 0,9 0,6 1 --- 0,6 1,2 R410A R410A R410A R410A R410A R410A R410A 2,9 1 2,9 1 3 1 3,9 1 4,2 1 5 2 4,3 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,42 4,31 5,98 6,36 4,44 4,35 5,95 6,33 4,3 4,27 5,98 6,35 4,03 4,07 6,14 6,53 4,12 4,1 5,3 5,63 4,18 4,19 6,26 6,66 4,23 4,14 5,56 5,92 50 65,4 51 66,4 52 67,4 53 68,8 53 68,9 53 68,9 53 68,9 1000 650 1400 1000 650 1400 1000 650 1400 1000 650 1400 1200 750 1700 1200 750 1700 1200 750 1700 258 260 270 281 440 450 444 1 1/2" -- 1 1/2" -- 1 1/2" -- 2" -- 2" -- 2" -- 2" -- 1" 1" 1" 1" 1" -- 1" SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg PLANT/EXHAUST EXCHANGER Inlet / outlet – ISO228/1-G M Ø Inlet / outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Gross value - Referred to hot water outlet temperature at 45°C and chilled water temperature 15/10°C 3. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 123 ➜ Heat pump on water side - EWMH W 27 / 570 | EWMH W MODEL 48.2 54.1 54.2 60.1 60.2 70.1 70.2 55,6 12,8 25,5 63,8 14,9 27,9 63 14,5 27,4 69,1 17 32,5 69,5 16,6 32,1 80,9 20,3 41,5 83 19,3 39,8 Water flow rate m³/h Pressure drop kPa 9,5 29 10,9 50 10,8 28 11,9 44 11,9 28 13,9 50 14,3 29 Water flow rate m³/h Pressure drop kPa 11,8 38 13,6 60 13,4 37 14,9 52 14,9 37 17,5 60 17,7 37 70,2 16,5 30,6 80 19,2 34,1 78,9 18,6 33,3 87,5 21,5 39 87,8 21 38,4 103 25,4 48,5 99,2 24,4 46,7 Water flow rate m³/h Pressure drop kPa 9,2 27 10,5 46 10,4 26 11,4 41 11,5 27 13,4 47 14,3 25 Water flow rate m³/h Pressure drop kPa 9,5 26 10,9 40 10,8 25 11,9 34 11,9 25 13,9 39 12,9 24 ---- 9,5 1,6 7 ---- 10,3 1,8 8,2 ---- 12,1 2,1 6,6 ---- scroll scroll scroll scroll scroll scroll scroll 2 44 140 2 2 50 143 2 2 50 143 2 2 62 171 2 2 62 171 2 2 68 207 2 2 68 207 2 1 1 1 1 1 1 1 4,2 13,4 3,9 15,3 4,2 15,1 3,9 16,7 4,2 16,7 4,7 19,5 6,4 20,1 1 1 1 1 1 1 1 4,2 16,5 3,9 19 4,2 18,8 3,9 20,9 4,2 20,9 4,7 24,5 6,4 24,8 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kW Water flow rate m³/h Pressure drop kPa COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Water volume l Max water flow rate m³/h CONDENSER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY ENERGY EFFIFICIENCY INDEXES V/Ph/Hz EER – Energy Efficiency Ratio kW/kW COP – Coefficient of Performance kW/kW ESEER - Eurovent Standard IPLV - ARI 550/590 -- 1 -- 1 -- 1 -- --- 0,8 1,4 --- 0,8 1,5 --- 1 1,7 --- R410A R410A R410A R410A R410A R410A R410A 5,7 2 5,7 1 5,7 2 5,8 1 5,7 2 6,6 1 8,1 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,34 4,25 6,56 6,97 4,28 4,17 5,49 5,84 4,34 4,24 6,27 6,67 4,06 4,07 5,19 5,52 4,19 4,18 5,91 6,28 3,99 4,06 5,56 5,91 4,3 4,07 6,43 6,83 53 68,9 54 69,9 54 69,9 55 70,9 55 70,9 56 71,9 56 71,9 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 455 455 468 460 485 465 495 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- 2" -- -- 1" -- 1" -- 1" -- SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg PLANT/EXHAUST EXCHANGER Inlet / outlet – ISO228/1-G M Ø Inlet / outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Gross value - Referred to hot water outlet temperature at 45°C and chilled water temperature 15/10°C 3. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 124 90.1 90.2 120.1 120.2 150.1 150.2 170.2 175.1 190.2 200.1 200.2 220.1 106 25,9 47,8 105 25,4 47,2 132 32,7 60,5 132 32,3 60 172 41,5 74,8 170 41,2 74,3 200 45,8 88,9 195 48,6 90,2 228 51,3 94,9 222 53 94,7 224 52,9 94,6 265 61,7 111 18,2 46 18,1 29 22,7 48 22,6 38 29,5 46 29,2 42 34,3 42 33,5 56 39 34 38,1 46 38,4 52 45,5 52 22,8 52 22,7 36 28,6 53 28,4 47 37 45 36,6 47 42,6 70 42,2 78 48,3 42 47,6 61 47,9 70 56,6 68 135 32,6 56,6 134 31,8 55,6 169 41 70,6 177 38,5 70,1 217 52,2 89,4 216 51,8 88,8 250 57,2 104 249 60,9 105 276 64 112 279 65,1 112 280 64,9 112 334 77,5 133 17,6 43 17,5 27 21,9 45 23,8 36 28,3 44 28,3 40 33,2 39 33,5 51 36,5 29 36,8 43 37 49 44,1 49 18,2 35 18,1 24 22,7 34 22,6 28 29,5 30 29,2 32 34,3 44 32,4 53 39 33 38,1 41 38,4 47 45,5 46 15,9 2,7 6,7 ---- 19,9 3,4 7,3 ---- 25,7 4,4 9,3 25,7 4,4 7,5 30,1 5,2 10,2 29,4 5,1 7,2 33,1 5,7 7,2 33,3 5,7 9,2 33,6 5,8 7,5 40 6,9 9,5 scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll 2 80 265 2 2 80 265 2 2 97 321 2 2 97 321 2 2 131 375 2 2 131 375 2 4 148 333 2 3 146 369 3 4 160 345 2 2 164 466 2 2 164 466 2 3 197 441 3 1 1 1 1 1 1 1 1 1 1 1 1 5,8 25,5 6,7 25,3 7,2 31,8 8,3 31,7 8,7 41,3 12,3 41,9 12,3 48 11,1 46,9 20,3 54,6 20,7 53,3 20,3 53,8 20,7 63,7 1 1 1 1 1 1 1 1 1 1 1 1 5,8 31,9 6,7 31,8 7,2 40 8,3 39,8 8,7 51,8 12,3 51,2 12,3 59,6 11,1 59,1 20,3 67,6 20,7 66,6 20,3 67,1 20,7 79,3 1 -- 1 -- 1 2 2 1 2 1 2 1 1,7 2,3 --- 2,1 2,8 --- 4 3,6 2 3,6 2 4,3 5,3 4,1 3,4 4,7 5,3 4,7 3,4 4,7 6,3 5,6 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 8,7 1 10,4 2 10,7 1 12,7 2 12,4 1 17 2 17,8 2 16 1 23,9 2 22,4 1 22,8 2 23,1 1 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,09 4,14 5,3 5,63 4,13 4,21 6,08 6,46 4,04 4,12 5,24 5,57 4,09 4,6 6,11 6,49 4,14 4,16 5,2 5,53 4,13 4,17 6,12 6,51 4,37 4,37 5,59 5,76 4,01 4,09 6,25 6,65 4,44 4,31 6,56 6,76 4,19 4,29 5,27 5,61 4,23 4,31 6,13 6,52 4,29 4,31 6,5 6,91 61 76,9 61 76,9 64 80,1 64 80,1 64 81 64 81 64 81 65,8 82,8 64 81 64 81 64 81 65,8 82,8 1200 750 1700 1200 750 1700 1200 750 1700 1200 750 1700 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1200 1740 715 760 775 788 1022 1030 1130 1152 1315 1085 1115 1302 -73,1 -73,1 -73,1 -73,1 -73,1 -73,1 -73,1 -73,1 -88,9 -88,9 -88,9 -88,9 1 1/4" -- 1 1/4" -- 2" 2 x 1" 2 x 1 1/4" 2" 2 x 1 1/4" 2" 2 x 1 1/4" 2" ➜ 125 Heat pump on water side - EWMH W 27 / 570 | EWMH W MODEL 240.2 290.1 300.2 340.2 380.2 460.2 570.2 270 64,5 120 331 79,3 142 339 82,4 149 394 94,2 169 436 106 189 523 123 222 655 160 285 Water flow rate m³/h Pressure drop kPa 46,3 61 56,8 49 58,2 70 67,5 70 74,8 64 89,8 63 112 85 Water flow rate m³/h Pressure drop kPa 57,9 81 71,1 60 73 89 84,5 86 93,8 74 112 64 141 83 342 80,7 139 417 97,4 168 431 104 177 497 117 201 550 130 225 660 154 264 828 197 339 Water flow rate m³/h Pressure drop kPa 44,9 58 54,9 46 56,3 66 65,3 66 72,2 60 87,1 59 109 79 Water flow rate m³/h Pressure drop kPa 46,3 54 56,8 40 58,2 59 67,5 57 74,8 49 89,8 43 112 55 HEATING CAPACITY kW Water flow rate m³/h Pressure drop kPa 40,7 7 7,6 49,8 8,6 9,3 51,1 8,8 9,2 59,2 10,2 12,4 65,5 11,3 8,9 79 13,6 9,3 98,5 17 9 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity Maximum current Starting current Capacity steps EVAPORATOR n. A A n. n. Water volume l Max water flow rate m³/h CONDENSER n. Water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGER n. Water volume l Max water flow rate m³/h REFRIGERANT scroll scroll scroll scroll scroll scroll 3 194 418 3 4 262 507 4 4 295 597 4 4 328 630 4 6 393 637 6 6 492 794 6 1 1 1 1 1 1 1 27 64,8 20,3 79,5 27,5 81,5 33,8 94,5 44,6 104,7 44,6 125,7 57,2 156,8 1 1 1 1 1 1 1 27 81,1 20,3 99,6 27,5 102,2 33,8 118,3 44,6 131,3 44,6 156,8 57,2 197,4 2 1 2 2 2 2 2 4,2 5,8 8 7 8 7,2 8 8,4 10,6 9,2 12,6 11,1 16 13,9 R410A R410A R410A R410A R410A R410A R410A 24,7 2 30,3 1 31,6 2 31,1 2 48,1 2 49,5 2 62,4 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,19 4,24 5,64 5,99 4,17 4,28 6,35 6,75 4,11 4,14 5,76 6,13 4,18 4,25 5,87 6,24 4,11 4,23 5,77 6,14 4,25 4,29 6,12 6,51 4,09 4,2 6,05 6,43 67 84,1 65,8 82,8 67 84,1 67 84,5 67 84,5 68,8 86,3 68,8 86,3 Length mm Width mm Height mm 1800 1200 1740 1800 1200 1740 1800 1200 1740 1800 1800 1740 1800 1800 1740 1800 1800 1740 1800 1800 1740 kg 1545 1403 1590 1665 1775 2270 2300 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 -88,9 2 x 1 1/4" 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" Total refrigerant charge (optional excluded) kg Gas circuit n. POWER SUPPLY ENERGY EFFIFICIENCY INDEXES scroll 4 246 584 4 V/Ph/Hz EER – Energy Efficiency Ratio kW/kW COP – Coefficient of Performance kW/kW ESEER - Eurovent Standard IPLV - ARI 550/590 SOUND LEVEL Average sound pressure level [LPm] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS PLANT/EXHAUST EXCHANGER Inlet / outlet – ISO228/1-G M Ø Inlet / outlet – OD Ø mm PARTIAL HEAT RECOVERY Inlet / outlet – ISO228/1-G M Ø 1. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C. 2. Gross value - Referred to hot water outlet temperature at 45°C and chilled water temperature 15/10°C 3. Gross value - Referred to chilled water temperature 12/7°C; condenser water temperature 30/35°C and recovery hot water temperature 40/45°C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 126 127 Water Cooled Chiller | EWSH W 410 / 1610 Heat pump on water side Screw ❯❯Cooling Capacity from 406 to 1604 KW ❯❯Heating capacity from 477 to 1976 KW ❯❯Size = 14 ❯❯Refrigerant : R134 A ❯❯EER up to 5.06 ❯❯ESSEER up to 5.72 ❯❯COP up to 5.30 Main Functions: ❯❯Reversible on hydraulic circuit ❯❯Twin Screw compressors ❯❯Shell and tube evaporator high efficiency ❯❯Shell and tube condenser high efficiency ❯❯Linear Modulating control capacity 25…100 % ❯❯2 cooling circuits Main accessories and options Code 118 119 171 550 731 780 919 923 926 931 Brine version kit A Brine version kit B Rubber antivibration holders Stop valve on compressor suction line Safety water flow switch Noise absorption box Clock card COM MBUS/JBUS serial board LON serial board BACnet Ethernet - SNMP - TCP/IP serial board 932 BACnet MS/TP serial board 942 Serial card for GSM Modem 943 Data Logger Available Versions: ❯❯Brine version Product Advantages ❯❯2 cooling circuits ❯❯Plug and play, robust and reliable ❯❯Leaving evaporator Temperature up to -10°C ❯❯Microprocessor control universal dialog, easy to read and acces to all informations ❯❯Electronic expansion valve STD ❯❯Input for air ambiant t° ❯❯Service valves gas discharge and liquid line ❯❯EUROVENT CERTIFIED ❯❯Large operating range WORKING LIMITS - COOLING - HEATING Values are indicative. The working temperatures are influenced by a series of variables as: Working conditions, Thermal load, Settings, etc.., Data to be confirmed with the selection software (°C) 20 Evaporator outlet temperature 15 10 5 Glycol solu)on 0 Glycol solu)on + brine Kit A -5 Glycol solu)on + brine Kit B -10 -13 15 20 25 30 35 40 45 50 55 60 65 (°C) Condenser water outlet temperature 128 EWSH W MODEL 410 460 510 540 610 700 790 394 82,5 148 443 92,4 178 494 103 195 551 109 202 603 134 225 656 144 250 740 163 273 Water flow rate m³/h Pressure drop kPa 67,7 10 76,1 16 84,7 17 94,6 22 103 24 113 14 127 12 Water flow rate m³/h Pressure drop kPa 82,6 10 92,8 12 103 15 114 1 128 23 139 18 156 22 477 94,8 244 533 106 247 598 119 289 666 128 295 736 144 240 830 159 271 963 182 304 Water flow rate m³/h Pressure drop kPa 65,7 13 73,4 18 82,4 19 92,6 22 102 26 115 8 134 6 Water flow rate m³/h Pressure drop kPa 67,7 7 76,1 2 84,7 1 94,6 4 103 16 113 16 127 17 HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa 49,7 8,56 4,6 55,5 9,57 4,2 62,3 10,7 3,7 70 12,1 3,5 77 13,3 3,3 87,2 15 3,4 101 17,5 3,8 twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew 2 205 383 25...100 2 236 469 25...100 2 270 630 25...100 2 288 639 25...100 2 330 811 25...100 2 367 544 25...100 2 414 568 25...100 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity n. Maximum current A Starting current A Stepless capacity control EVAPORATOR n. Water volume l Max water flow rate m³/h CONDENSER n. Total water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Total water volume l Max water flow rate m³/h REFRIGERANT 1 1 1 1 1 1 1 149 95 142 100 255 127 255 127 255 127 255 127 237 154 2 2 2 2 2 2 2 78 98 78 98 99 116 99 116 99 116 99 116 109 170 2 2 2 2 2 2 2 14,4 37 14,4 37 19,2 37 19,2 37 19,2 37 27 37 37 37 R134a R134a R134a R134a R134a R134a R134a 65 2 65 2 155 2 155 2 155 2 155 2 142 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,78 5,03 5,41 5,72 4,79 5,03 5,34 5,42 4,8 5,03 5,25 5,39 5,06 5,2 5,72 6,04 4,5 5,11 5,12 5,44 4,56 5,22 5,19 5,51 4,54 5,29 5,16 5,49 74 91,8 74 91,8 74 91,8 74 91,8 79 96,8 79 96,8 79 97,6 3359,5 975 1498 3359,5 975 1498 3349,5 1013 1618 3349,5 1013 1618 3435 1007 1740 3514 1060 1780 3894 1210 1888 3237 3268 3498 3498 3590 3720 3967 168,3 168,3 168,3 168,3 168,3 168,3 219,1 Inlet/outlet – (ISO228/1) n x Ø Inlet/outlet – (OD) n x Ømm 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- 2 x 3" -- Inlet/outlet – (ISO228/1) n x Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER – Energy Efficiency Ratio COP – Coefficient of Performance ESEER - Eurovent Standard IPLV - ARI 550/590 SOUND LEVEL Sound pressure level [Lp] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS Length mm Width mm Height mm NET WEIGHT HYDRAULIC CONNECTIONS kg EVAPORATOR Inlet/outlet – (OD) Ø mm CONDENSER PARTIAL HEAT RECOVERY 1. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C. 2. Gross value - Referred to chilled water temperature 15/10°C; water outlet to the condenser 45°C. 3. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C and hot water temperature 40/45°C. 129 4. Sound pressure level [Lp] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 ➜ Heat pump on water side - EWSH W 410 / 1610 | EWSH W MODEL 940 1050 1110 1140 1310 1460 1610 880 196 299 973 218 349 1031 228 362 1073 236 385 1224 269 463 1365 297 516 1505 335 567 Water flow rate m³/h Pressure drop kPa 151 17 167 24 177 23 184 21 210 24 234 33 258 41 Water flow rate m³/h Pressure drop kPa 186 17 206 18 218 23 227 20 259 16 288 17 319 20 1115 215 335 1257 240 386 1346 255 406 1412 271 441 1569 298 516 1766 333 575 1976 378 642 Water flow rate m³/h Pressure drop kPa 155 13 175 25 187 21 196 22 218 20 246 35 275 43 Water flow rate m³/h Pressure drop kPa 151 13 167 12 177 15 184 13 210 11 234 12 258 14 HEATING CAPACITY kW Heat recovery water flow m³/h Heat recovery pressure drop kPa 117 20,2 4,6 132 22,8 5,2 142 24,4 7,2 148 25,6 8,3 165 28,5 10,9 186 32,1 13,5 208 35,8 16,5 twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew twinscrew 2 474 611 25...100 2 536 721 25...100 2 567 827 25...100 2 615 903 25...100 2 710 1058 25...100 2 798 1182 25...100 2 896 1324 25...100 SUMMER WORKING MODE (1) COOLING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER WINTER WORKING MODE (2) HEATING CAPACITY kW Compressors power input kW Compressors operating current [OA] A EVAPORATOR CONDENSER PARTIAL HEAT RECOVERY (3) COMPRESSORS Quantity n. Maximum current A Starting current A Stepless capacity control EVAPORATOR n. Water volume l Max water flow rate m³/h CONDENSER n. Total water volume l Max water flow rate m³/h PARTIAL HEAT RECOVERY EXCHANGERS n. Total water volume l Max water flow rate m³/h REFRIGERANT 1 1 1 1 1 1 1 229 172 276 172 276 172 370 220 368 245 357 267 431 312 2 2 2 2 2 2 2 109 186 135 216 135 216 155 240 171 260 182 284 210 320 2 2 2 2 2 2 2 32 67 34 67 34 67 39 67 39 67 54 67 54 67 R134a R134a R134a R134a R134a R134a R134a 136 2 130 2 130 2 121 2 180 2 176 2 172 2 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 4,49 5,19 5,08 5,37 4,46 5,24 5,06 5,34 4,52 5,28 5,16 5,46 4,55 5,21 5,04 5,17 4,55 5,27 5,04 5,18 4,6 5,3 5,1 5,24 4,49 5,23 4,99 5,12 82 100,6 82 100,6 82 101,2 82 101,2 82 101,2 84 103,6 84 103,6 Length mm Width mm Height mm 3894 1210 1888 3894 1210 1888 3932,5 1218 1890 3874 1287 1975 4273 1284 2084 4273 1284 2084 4352 1284 2108 kg 4071 4835 4949 5031 5549 6407 6537 219,1 219,1 219,1 219,1 219,1 273 273 Inlet/outlet – (ISO228/1) n x Ø Inlet/outlet – (OD) n x Ømm 2 x 3" -- 2 x 3" -- 2 x 3" -- -2 x 114,3 -2 x 114,3 -2 x 114,3 -2 x 141,3 Inlet/outlet – (ISO228/1) n x Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" Total refrigerant charge (optional excluded) kg Gas circuits n. POWER SUPPLY ENERGY EFFICIENCY INDEXES V/Ph/Hz EER – Energy Efficiency Ratio COP – Coefficient of Performance ESEER - Eurovent Standard IPLV - ARI 550/590 SOUND LEVEL Sound pressure level [Lp] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS NET WEIGHT HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet – (OD) Ø mm CONDENSER PARTIAL HEAT RECOVERY 1. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C. 2. Gross value - Referred to chilled water temperature 15/10°C; water outlet to the condenser 45°C. 3. Gross value - Referred to chilled water temperature 12/7°C; water to the condenser 30/35°C and hot water temperature 40/45°C. 130 4. Sound pressure level [Lp] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 - 2 131 132 Condensing Units 133 Air Cooled condensing units | CDN air coolEd condEnSing unit - cooling ModE ooling capacity: from 19 to 83 kW C Refrigerant: r407c Size: 8 Configurations: Monobloc system Product Advantages eather resistant casing with external panels coated with W powder-based epoxy paint colour ral 9001. compatible with any indoor unit. Easy service acces to main components. Hermetic Scroll compressor with crankcase heater. low noise fan. Phase controller. External HP and lP pressure taps. Electrical, refrigeration and thermal protection devices. Main accessories and options aZ version: complete with standard component B and fan speed controller. Bac version: BaZ version + suction accumulator. Bal version: BaZ version + suction accumulator + liquid receiver. WORKING LIMITS (to be confirmed following selection software issue) Cooling mode Minimum outdoor air temperature (with fan speed controller) Maximum outdoor air temperature -10°C 46°C DB 134 CDN - UNIT CDN 205 CDN 305 CDN 405 M CDN 405 CDN 505 CDN 605 CDN 755 CDN 905 CAPACITIES Cooling capacity kW 18,6 27,8 36,0 35,1 44,4 55,6 69,1 83,0 6,5 9,5 12,4 13,0 16,1 19,0 22,9 27,5 1 1 1 2 2 2 2 2 1 1 1 2 2 2 2 2 8600 9000 16000 2x9000 2x9000 2x9000 2x16000 2x16000 78 82 83 82 84 87 87 87 Max current A 16,5 24 32 38 39 47 56 67 Max starting current A 104 131 121 123 113 153 192 234 1-1/8" 1-3/8" 1-1/8" 1-1/8" 1-1/8" 1-3/8" 1-3/8" 1/2" 5/8" 1/2" 1/2" 1/2" 5/8" 5/8" Power input kW Number of refrigerant circuits VENTILATION Number of fan Nominal airflow m³/h SOUND LEVELS Sound power level dB(A) POWER SUPPLy Power supply 400V/3P + N + Earth/50 Hz REFRIGERANT CONNECTION Suction pipe diameter pouces 1-1/8" liquid pipe diameter pouces 1/2" DIMENSIONS (LxWxH) mm 900x800x1060 1003xx1003x1094 1003xx1003x1250 1708x1123x972 1708x1123x1171 1708x1123x1171 2213x1345x1304 2213x1345x1454 164 187 245 317 378 405 490 530 7SP112103 7SP112107 7SP112134 7SP112144 7SP112111 7SP112115 7SP112140 7SP112149 WEIGHT unit weight kg PRODUCT CODES BAC Code BAL Code 7SP112220 7SP112208 7SP112198 7SP112230 7SP112216 7SP112217 7SP112218 7SP112219 BAZ Code 7SP112102 7SP112106 7SP112133 7SP112182 7SP112110 7SP112114 7SP112139 7SP112148 135 136 Air cooled condensers Dry coolers 137 Air Condenser | ACCL 11 / 280 for cooling ACCH 11 / 280 for Reversible R410A ❯❯ACCL for cooling ❯❯ACCH for Reversible ❯❯ Capacity from 12 to 300 KW ❯❯Size = 19 ❯❯Réfrigérants : ❯❯R410A = ACCL only ❯❯R134A, R407C = ACCL ACCH Main Functions: ❯❯A xial fans with low sound profil blades ❯❯Valves on gas and liquid line for coupling to refrigerant pipe. The valves are supplied not installed. The condenser is supplied with nitrogen seal. ❯❯Thermostatic expansion valve. (only on ACCH) ❯❯Liquid and moisture indicator. (only on ACCH) ❯❯Dryer and anti-acid gas filter. (only on ACCH) ❯❯Solenoid valve (only on ACCH) ❯❯Non return valve (only on ACCH) ❯❯Terminals for 0÷10V signal for condensing control system (connect to indoor machine). ❯❯ Terminals for alarm signal (connect to indoor machine). ❯❯Fans speed regulator for condensing control (only with axial fans). Main accessories and options Code 511 Legs for vertical air flow (kit) Available Versions ❯❯ACCL for cooling ❯❯ACCH for Reversible ❯❯One phase up 140 KW ❯❯Version STD ❯❯Version low sound level LS ❯❯Version extra low sound level XLS Product Advantages ❯❯Simple and reliable ❯❯Choice for sound level ❯❯Integrated condensing control 138 ACCL ACCH STD MODEL 11 14 17 20 25 30 35 12,1 12 11,7 14,7 14,7 14,4 18,4 18,2 17,9 20,7 20,4 20 24,2 24,2 23,7 32,7 32,3 31,7 37,4 37,1 36,6 CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 1 1 1 1 1 1 1 m³/h Pa kW A 4900 0 0,25 1,2 4500 0 0,25 1,2 5200 0 0,25 1,2 6400 0 0,39 1,8 9600 0 0,53 2,9 9500 0 0,53 2,9 9100 0 0,53 2,9 dB(A) 63 63 63 65 67 67 67 COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 0,8 1,2 1,7 1,7 2 3 4 875 540 727 875 540 727 1200 540 727 1200 540 727 1400 665 1027 1400 665 1027 1400 665 1027 51 55 66 72 102 111 120 45 50 60 70 95 110 130 47,6 47,1 46,5 56,1 55,5 54,8 62,6 62 61,2 74 73,3 72,4 99,4 98,3 97 111 110 109 133 132 130 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 2 2 2 2 3 3 4 m³/h Pa kW A 12000 0 0,78 3,6 17000 0 1,08 5,7 16000 0 1,08 5,7 18000 0 1,08 5,7 28200 0 1,59 8,5 27200 0 1,59 8,5 37800 0 2,12 11,4 dB(A) 67,4 69,4 69,4 69,4 70,5 70,5 71,1 COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 4,7 4,1 5,5 7,7 8,7 11,6 11,6 1600 665 1027 1850 665 1027 1850 665 1027 2320 665 1140 3490 665 1150 3490 665 1150 4540 665 1150 153 175 188 214 240 270 320 140 185 210 250 280 151 150 149 201 198 195 232 231 228 276 273 270 307 304 301 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 4 6 6 8 8 m³/h Pa kW A 36000 0 2,12 11,4 56000 0 3,18 17,1 54000 0 3,18 17,1 74600 0 4,24 22,8 72000 0 4,24 22,8 dB(A) 71,1 71,5 71,5 72,2 72,2 V/ph/Hz 230/1/50 400/3/50+N(*) 400/3/50+N(*) 400/3/50+N(*) 400/3/50+N(*) 15,4 20,8 27,7 27,7 37 4540 665 1150 3490 665 2200 3490 665 2200 4540 665 2200 4540 665 2200 350 470 520 630 690 COMMON DATA POWER SUPPLY REFRIGERANT CHARGE contenance (3) kg DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg 1. Gross value - Referred to condensing temperature at 50°C and outdoor air temperature at 35°C. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 3. The condenser is supplied with nitrogen seal. For the refrigerant charge consider, in addition to the these value, even the refrigerant pipes for the connection to the indoor machine and lubricant oil in 10% ratio of charged refrigerant. 139 (*)Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. **Not Available with ACCH Air Condenser - ACCL ACCH 11 / 280 | ACCL ACCH LS MODEL 11 14 17 20 25 30 35 10,9 10,8 10,6 13,1 13,1 12,9 16,4 16,2 15,9 18,5 18,2 17,9 21,8 21,8 21,3 29,1 28,7 28,3 32,9 32,6 32,3 CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 1 1 1 1 1 1 1 m³/h Pa kW A 4165 0 0,21 1,2 3825 0 0,21 1,2 4420 0 0,21 1,2 5440 0 0,33 1,8 8160 0 0,45 2,9 8075 0 0,45 2,9 7735 0 0,45 2,9 dB(A) 59,1 59,1 59,1 61,1 63,1 63,1 63,1 COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 0,8 1,2 1,7 1,7 2 3 4 875 540 727 875 540 727 1200 540 727 1200 540 727 1400 665 1027 1400 665 1027 1400 665 1027 51 55 66 72 102 111 120 45 50 60 70 95 110 130 42 41,6 41,1 50,1 49,6 48,9 55,3 54,8 54,2 65,1 64,6 63,8 88,3 87,4 86,3 97,7 97,3 96,2 118 117 116 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 2 2 2 2 3 3 4 m³/h Pa kW A 10200 0 0,66 3,6 14450 0 0,92 5,7 13600 0 0,92 5,7 15300 0 0,92 5,7 23970 0 1,35 8,5 23120 0 1,35 8,5 32130 0 1,8 11,4 dB(A) 63,6 65,5 65,5 65,5 66,6 66,6 67,2 COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 4,7 4,1 5,5 7,7 8,7 11,6 11,6 1600 665 1027 1850 665 1027 1850 665 1027 2320 665 1140 3490 665 1150 3490 665 1150 4540 665 1150 153 175 188 214 240 270 320 140 185 210 250 280 133 132 131 179 176 174 205 203 201 245 243 240 270 268 265 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 4 6 6 8 8 m³/h Pa kW A 30600 0 1,8 11,4 47600 0 2,7 17,1 45900 0 2,7 17,1 63410 0 3,6 22,8 61200 0 3,6 22,8 dB(A) 67,2 67,7 67,7 68,3 68,3 V/ph/Hz 230/1/50 400/3/50+N(*) 400/3/50+N(*) 400/3/50+N(*) 400/3/50+N(*) 15,4 20,8 27,7 27,7 37 4540 665 1150 3490 665 2200 3490 665 2200 4540 665 2200 4540 665 2200 350 470 520 630 690 COMMON DATA POWER SUPPLY REFRIGERANT CHARGE contenance (3) kg DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg 1. Gross value - Referred to condensing temperature at 50°C and outdoor air temperature at 35°C. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 3. The condenser is supplied with nitrogen seal. For the refrigerant charge consider, in addition to the these value, even the refrigerant pipes for the connection to the indoor machine and lubricant oil in 10% ratio of charged refrigerant. 140 (*)Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. **Not Available with ACCH ACCL ACCH XLS MODEL 11 14 17 20 25 30 35 9,6 9,5 9,3 11,4 11,4 11,2 14,1 14 13,8 16,1 15,8 15,6 19,2 19,2 18,8 25,2 24,9 24,5 28,2 27,9 27,6 CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 1 1 1 1 1 1 1 m³/h Pa kW A 3430 0 0,18 1,2 3150 0 0,18 1,2 3640 0 0,18 1,2 4480 0 0,27 1,8 6720 0 0,37 2,9 6650 0 0,37 2,9 6370 0 0,37 2,9 dB(A) 54,5 54,5 54,5 56,5 58,5 58,5 58,5 COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 0,8 1,2 1,7 1,7 2 3 4 875 540 727 875 540 727 1200 540 727 1200 540 727 1400 665 1027 1400 665 1027 1400 665 1027 51 55 66 72 102 111 120 45 50 60 70 95 110 130 36,1 35,7 35,3 43,5 43,1 42,6 47,6 47,2 46,7 55,8 55,3 54,7 76,4 75,7 74,8 83,7 83,3 82,5 102 101 100 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 2 2 2 2 3 3 4 m³/h Pa kW A 8400 0 0,55 3,6 11900 0 0,76 5,7 11200 0 0,76 5,7 12600 0 0,76 5,7 19740 0 1,11 8,5 19040 0 1,11 8,5 26460 0 1,48 11,4 dB(A) 58,9 60,8 60,8 60,8 61,9 61,9 62,5 COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 4,7 4,1 5,5 7,7 8,7 11,6 11,6 1600 665 1027 1850 665 1027 1850 665 1027 2320 665 1140 3490 665 1150 3490 665 1150 4540 665 1150 153 175 188 214 240 270 320 140 185 210 250 280 114 113 112 155 153 151 175 173 172 212 210 208 231 229 227 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) n. 4 6 6 8 8 m³/h Pa kW A 25200 0 1,48 11,4 39200 0 1,48 17,1 37800 0 2,23 17,1 52220 0 2,23 22,8 50400 0 2,97 22,8 dB(A) 62,5 63 63 63,7 63,7 V/ph/Hz 230/1/50 400/3/50+N(*) 400/3/50+N(*) 400/3/50+N(*) 400/3/50+N(*) 15,4 20,8 27,7 27,7 37 4540 665 1150 3490 665 2200 3490 665 2200 4540 665 2200 4540 665 2200 350 470 520 630 690 COMMON DATA POWER SUPPLY REFRIGERANT CHARGE contenance (3) kg DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg 1. Gross value - Referred to condensing temperature at 50°C and outdoor air temperature at 35°C. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 3. The condenser is supplied with nitrogen seal. For the refrigerant charge consider, in addition to the these value, even the refrigerant pipes for the connection to the indoor machine and lubricant oil in 10% ratio of charged refrigerant. 141 (*)Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. **Not Available with ACCH Air Condenser | ACCL PF 11/144 for cooling ACCH PF 11/144 for Reversible R410A ❯❯ACCL for cooling ❯❯ACCH for Reversible ❯❯ Capacity from 12 to 300 KW ❯❯Size = 19 ❯❯Réfrigérants : ❯❯R410A = ACCL only ❯❯R134A, R407C = ACCL ACCH ❯❯Available static pressure from 50 to 500 Pa folowing sizes Main Functions: ❯❯Plug fan with EC motor ❯❯Valves on gas and liquid line for coupling to refrigerant pipe. The valves are supplied not installed. The condenser is supplied with nitrogen seal. ❯❯Thermostatic expansion valve. (only on ACCH) ❯❯Liquid and moisture indicator. (only on ACCH) ❯❯Dryer and anti-acid gas filter. (only on ACCH) ❯❯Solenoid valve (only on ACCH) ❯❯Non return valve (only on ACCH) ❯❯Terminals for 0÷10V signal for condensing control system (connect to indoor machine). ❯❯ Terminals for alarm signal (connect to indoor machine). Available Versions: ❯❯ACCL for cooling ❯❯ACCH for Reversible ❯❯One phase up 140 KW ❯❯Version STD ❯❯Version low sound level LS ❯❯Version extra low sound level XLS Product Advantages ❯❯Available static pressure ❯❯Simple and reliable ❯❯Choice for sound level ❯❯Integrated condensing control ❯❯EC motor ❯❯Low consumption 142 ACCL ACCH PF STD MODEL 11 14 17 20 25 12,1 12 11,7 15,6 15,6 15,3 18,2 18,2 17,9 21,6 21,6 21,3 25 25 24,7 n. 1 1 1 1 1 m³/h Pa Pa kW A 4900 50 375 0,38 1,6 4900 50 350 0,42 1,6 4900 50 332 0,45 1,6 4900 50 290 0,52 1,6 6400 50 748 0,64 4,3 61,6 61,6 61,5 61,5 67,1 CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Max esternal static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 0,8 1,2 1,7 2,6 2,5 Length mm Width mm Height mm 890 880 900 890 880 900 890 880 900 890 880 900 1190 880 900 kg 143 148 153 163 210 33 38 44 58 69 35,1 35,1 34,7 39,8 39,8 39,3 46,5 46,5 46 62 62 61,2 73,1 73,1 72,4 n. 1 1 1 2 2 m³/h Pa Pa kW A 8000 50 474 1,3 4,3 10000 50 298 1,14 3,6 10000 50 268 1,24 3,6 16000 50 552 2,18 8,6 16000 50 512 2,39 8,6 72 71,1 71,3 77,3 77,4 DIMENSIONS NET WEIGHT CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Max esternal static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 3,8 4,3 6,4 5,9 8,8 1190 880 900 1390 880 1300 1390 880 1300 1840 880 1300 1840 880 1300 222 284 310 387 421 86 108 114 144 91 91 89,9 113 113 111 122 122 121 154 154 152 n. 3 3 3 4 m³/h Pa Pa kW A 24000 50 542 3,34 12,9 32000 50 515 4,74 17,2 28000 50 204 5,63 12,9 36000 50 237 7,4 17,2 80,3 81,8 83,7 84,5 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Max esternal static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 10,2 9,4 10,3 14 2290 880 1300 1840 880 1800 2290 880 1300 1840 880 1800 515 625 557 673 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg 1. Gross value - Referred to condensing temperature at 50°C and outdoor air temperature at 35°C. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 3. The condenser is supplied with nitrogen seal. For the refrigerant charge consider, in addition to the these value, even the refrigerant pipes for the connection to the indoor machine and lubricant oil in 10% ratio of charged refrigerant. 143 (*)Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. **Not Available with ACCH PF Air Condenser - ACCL ACCH PF 11 / 144 | ACCL ACCH PF LS MODEL 11 14 17 20 25 10,8 10,5 10,2 13,7 13,7 13,3 15,9 15,9 15,5 18,8 18,8 18,4 21,6 21,6 21 n. 1 1 1 1 1 m³/h Pa Pa kW A 4165 50 375 0,26 1,6 4165 50 350 0,28 1,6 4165 50 332 0,3 1,6 4165 50 290 0,34 1,6 5440 50 748 0,42 4,3 57,7 57,7 57,6 57,6 63,2 CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Max esternal static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 0,8 1,2 1,7 2,6 2,5 Length mm Width mm Height mm 890 880 900 890 880 900 890 880 900 890 880 900 1190 880 900 kg 143 148 153 163 210 33 38 44 58 69 30,2 30,2 29,4 34,5 34,5 33,7 40,1 40,1 39,3 53,4 53,4 51,8 62,7 62,7 61,3 n. 1 1 1 2 2 m³/h Pa Pa kW A 6800 50 474 0,83 4,3 8500 50 298 0,74 3,6 8500 50 268 0,8 3,6 13600 50 552 1,4 8,6 13600 50 512 1,51 8,6 68,1 67,2 67,4 73,4 73,5 DIMENSIONS NET WEIGHT CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Max esternal static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 3,8 4,3 6,4 5,9 8,8 1190 880 900 1390 880 1300 1390 880 1300 1840 880 1300 1840 880 1300 222 284 310 387 421 86 108 114 144 78,6 78,6 76,2 98,9 98,9 96,2 105 105 102 131 131 127 n. 3 3 3 4 m³/h Pa Pa kW A 20400 50 542 2,15 12,9 27200 50 515 3,04 17,2 23800 50 204 3,57 12,9 30600 50 237 4,69 17,2 76,4 77,9 79,8 80,6 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg CAPACITY (1) **With R410A refrigerant charge kW With R407C refrigerant charge kW With R134a refrigerant charge kW AXIAL FANS Air flow External static pressure Max esternal static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY V/ph/Hz REFRIGERANT CHARGE contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 10,2 9,4 10,3 14 2290 880 1300 1840 880 1800 2290 880 1300 1840 880 1800 515 625 557 673 DIMENSIONS Length mm Width mm Height mm NET WEIGHT kg 1. Gross value - Referred to condensing temperature at 50°C and outdoor air temperature at 35°C. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 3. The condenser is supplied with nitrogen seal. For the refrigerant charge consider, in addition to the these value, even the refrigerant pipes for the connection to the indoor machine and lubricant oil in 10% ratio of charged refrigerant. 144 (*)Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. **Not Available with ACCH PF ACCL ACCH PF XLSPFTAILLE XLS MODEL 11 14 17 20 25 9,5 9,3 9,1 11,9 11,9 11,6 13,7 13,7 13,4 16 16 15,7 18,7 18,7 18,2 n. 1 1 1 1 1 m³/h Pa Pa kW A 3430 50 375 0,16 1,6 3430 50 350 0,17 1,6 3430 50 332 0,19 1,6 3430 50 290 0,21 1,6 4480 50 748 0,26 4,3 53,1 53,1 53 53 58,6 PUISSANCE(1)(1) CAPACITY Avec **With Charge R410A de refrigerant réfrigérant charge R410A kW AvecWith Charge R407C de refrigerant réfrigérant charge R407C kW AvecWith Charge R134a de refrigerant réfrigérant charge R134A kW VENTILATEURS AXIAL FANS AXIAUX Débit Air d'air flow Pression External statique staticdisponible pressure Pression statique Max esternal disponible staticMaximum pressure Puissance Operating absorbée power nominale input Intensité maximale Max operating de fonctionnement current (FLA) Niveaux sonore AVERAGE SOUND PRESSURE Moyenne (2) LEVEL (2) dB(A) CARACTERISTIQUES COMMON DATA COMMUNES ALIMENTATION POWER SUPPLYELECTRIQUE V/ph/Hz REFRIGERANT CHARGE CHARGE DE REFRIGERANT contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 0,8 1,2 1,7 2,6 2,5 Longueur Length mm Largeur Width mm Hauteur Height mm 890 880 900 890 880 900 890 880 900 890 880 900 1190 880 900 kg 143 148 153 163 210 33 38 44 58 69 25,8 25,8 25,2 29,7 29,7 29,1 34 34 33,5 46,2 46,2 45 53,4 53,4 52,4 n. 1 1 1 2 2 m³/h Pa Pa kW A 5600 50 474 0,5 4,3 7000 50 298 0,49 3,6 7000 50 268 0,48 3,6 11200 50 552 0,84 8,6 11200 50 512 0,92 8,6 63,5 62,6 62,8 68,8 68,9 DIMENSIONS POIDS NET WEIGHT NET PUISSANCE(1)(1) CAPACITY Avec **With Charge R410A de refrigerant réfrigérant charge R410A kW AvecWith Charge R407C de refrigerant réfrigérant charge R407C kW AvecWith Charge R134a de refrigerant réfrigérant charge R134A kW VENTILATEURS AXIAL FANS AXIAUX Débit Air d'air flow Pression External statique staticdisponible pressure Pression statique Max esternal disponible staticMaximum pressure Puissance Operating absorbée power nominale input Intensité maximale Max operating de fonctionnement current (FLA) Niveaux sonore AVERAGE SOUND PRESSURE Moyenne (2) LEVEL (2) dB(A) CARACTERISTIQUES COMMON DATA COMMUNES ALIMENTATION POWER SUPPLYELECTRIQUE V/ph/Hz REFRIGERANT CHARGE CHARGE DE REFRIGERANT contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 3,8 4,3 6,4 5,9 8,8 1190 880 900 1390 880 1300 1390 880 1300 1840 880 1300 1840 880 1300 222 284 310 387 421 86 108 114 144 68,1 68,1 66,4 85,9 85,9 83,8 89,8 89,8 87,9 113 113 110 n. 3 3 3 4 m³/h Pa Pa kW A 16800 50 542 1,29 12,9 22400 50 515 1,82 17,2 19600 50 204 2,1 12,9 25200 50 237 2,76 17,2 71,8 73,3 75,2 76 DIMENSIONS Longueur Length mm Largeur Width mm Hauteur Height mm POIDS NET WEIGHT NET kg PUISSANCE(1)(1) CAPACITY Avec **With Charge R410A de refrigerant réfrigérant charge R410A kW AvecWith Charge R407C de refrigerant réfrigérant charge R407C kW AvecWith Charge R134a de refrigerant réfrigérant charge R134A kW VENTILATEURS AXIAL FANS AXIAUX Débit Air d'air flow Pression External statique staticdisponible pressure Pression statique Max esternal disponible staticMaximum pressure Puissance Operating absorbée power nominale input Intensité maximale Max operating de fonctionnement current (FLA) Niveaux sonore AVERAGE SOUND PRESSURE Moyenne (2) LEVEL (2) dB(A) CARACTERISTIQUES COMMON DATA COMMUNES ALIMENTATION POWER SUPPLYELECTRIQUE V/ph/Hz REFRIGERANT CHARGE CHARGE DE REFRIGERANT contenance (3) kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 10,2 9,4 10,3 14 2290 880 1300 1840 880 1800 2290 880 1300 1840 880 1800 515 625 557 673 DIMENSIONS Longueur Length mm Largeur Width mm Hauteur Height mm POIDS NET WEIGHT NET kg 1. Gross value - Referred to condensing temperature at 50°C and outdoor air temperature at 35°C. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 3. The condenser is supplied with nitrogen seal. For the refrigerant charge consider, in addition to the these value, even the refrigerant pipes for the connection to the indoor machine and lubricant oil in 10% ratio of charged refrigerant. 145 (*)Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. **Not Available with ACCH PF Dry coolers | DC 14 / 280 ventilators axiaux ❯❯Capacity from 8 to 172 KW ❯❯Size = 10 Principales fonctions : ❯❯Axial fans with low sound profil blades ❯❯Terminals for 0÷10V signal for condensing control system (connect to indoor machine). ❯❯Terminals for alarm signal (connect to indoor machine). ❯❯Fans speed regulator for condensing control (only with axial fans). ❯❯Heat exchanger coil with copper tubes and high Principaux accessoires et options efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Code 511 Legs for vertical air flow (kit) Versions Disponibles : ❯❯One phase up 140 KW ❯❯Version STD ❯❯Version low sound level LS 85% ❯❯Version low sound level LS 70% Avantages Produit ❯❯Simple and reliable ❯❯Choice for sound level ❯❯Integrated condensing control 146 DC MODEL CAPACITY (1) 14 20 35 45 60 8,3 11,7 22,6 26,4 31,8 1,5 24 4 2,1 21 5,7 4 26 15,7 4,7 16 15,2 5,7 8 17,9 n. 1 1 1 2 2 m³/h Pa kW A 4500 0 0,25 0,7 6400 0 0,39 1,8 9100 0 0,53 2,9 12000 0 0,78 3,6 16000 0 1,08 5,7 63 65 67 67,4 69,4 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 875 540 727 1200 540 727 1400 665 1027 1600 665 1027 1850 665 1027 73 122 156 191 kW DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 56 70 110 140 210 280 CAPACITY (1) kW 40,2 62,2 86,1 124 172 7,2 12 25,1 11,1 17 37,7 15,4 40 72,8 22,1 17 75,3 30,8 40 100,4 n. 2 3 4 6 8 m³/h Pa kW A 18000 0 1,08 5,7 27200 0 1,59 8,5 36000 0 2,12 11,4 54000 0 3,18 17,1 72000 0 4,24 22,8 69,4 70,5 71,1 71,5 72,2 230/1/50 230/1/50 230/1/50 400/3/50+N(*) 400/3/50+N(*) 2320 665 1140 3490 665 1150 4540 665 1150 3490 665 2200 4540 665 2200 219 227 359 533 708 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 1. Valeurs brutes - entrée d’air à 35°C avec température entrée eau 45°C - 20% de glycol 2.Pression de niveau sonore Lpm 1 m suivant ISO EN 3744 (*) disponible aussi en 230V / 1PH/ 50 HZ, se réferrer au schéma electrique de l’unité 147 Axial fans - DC 14 / 280 | DC LS 85% MODEL CAPACITY (1) 14 20 35 45 60 7,3 10,4 19,8 23,3 28 1,3 19 4 1,9 17 5,7 3,5 21 15,7 4,2 13 15,2 5 6 17,9 n. 1 1 1 2 2 m³/h Pa kW A 3825 0 0,21 0,7 5440 0 0,33 1,8 7735 0 0,45 2,9 10200 0 0,66 3,6 13600 0 0,92 5,7 59,1 61,1 63,1 63,6 65,5 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 875 540 727 1200 540 727 1400 665 1027 1600 665 1027 1850 665 1027 73 122 156 191 kW DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 56 70 110 140 210 280 CAPACITY (1) kW 35,3 54,8 75,9 109 152 6,3 10 25,1 9,8 14 37,7 13,6 32 72,8 19,5 14 75,3 27,1 32 100,4 n. 2 3 4 6 8 m³/h Pa kW A 15300 0 0,92 5,7 23120 0 1,35 8,5 30600 0 1,8 11,4 45900 0 2,7 17,1 61200 0 3,6 22,8 65,5 66,6 67,2 67,7 68,3 230/1/50 230/1/50 230/1/50 400/3/50+N(*) 400/3/50+N(*) 2320 665 1140 3490 665 1150 4540 665 1150 3490 665 2200 4540 665 2200 219 227 359 533 708 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 1. Gross value – Characteristics referred to entering air at 35°C with hot water inlet temperature 45°C – 20% glycol. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. (*) Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. 148 DC LS 70% MODEL CAPACITY (1) 14 20 35 45 60 6,4 9 16,9 19,9 23,8 1,1 15 4 1,6 13 5,7 3 16 15,7 3,6 10 15,2 4,3 5 17,9 n. 1 1 1 2 2 m³/h Pa kW A 3150 0 0,18 0,7 4480 0 0,27 1,8 6370 0 0,37 2,9 8400 0 0,55 3,6 11200 0 0,76 5,7 54,5 56,5 58,5 58,9 60,8 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 875 540 727 1200 540 727 1400 665 1027 1600 665 1027 1850 665 1027 73 122 156 191 kW DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 56 70 110 140 210 280 CAPACITY (1) kW 30,2 46,9 65 93,2 130 5,4 7 25,1 8,4 11 37,7 11,6 25 72,8 16,7 10 75,3 23,3 25 100,4 n. 2 3 4 6 8 m³/h Pa kW A 12600 0 0,76 5,7 19040 0 1,11 8,5 25200 0 1,48 11,4 37800 0 2,23 17,1 50400 0 2,97 22,8 60,8 61,9 62,5 63 63,7 230/1/50 230/1/50 230/1/50 400/3/50+N(*) 400/3/50+N(*) 2320 665 1140 3490 665 1150 4540 665 1150 3490 665 2200 4540 665 2200 219 227 359 533 708 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 1. Gross value – Characteristics referred to entering air at 35°C with hot water inlet temperature 45°C – 20% glycol. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. (*) Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. 149 Dry coolers | DC PF 14 / 144 Plug Fans ❯❯Capacity from 8 to 89 KW ❯❯Size = 13 ❯❯Available static pressure from 50 to 500 Pa folowing sizes Main Functions: ❯❯Plug fan and EC motors ❯❯Terminals for 0÷10V signal for condensing control system (connect to indoor machine). ❯❯Terminals for alarm signal (connect to indoor machine). ❯❯Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Available Versions: ❯❯One phase up 140 KW ❯❯Version STD ❯❯Version low sound level LS 85% ❯❯Version low sound level LS 70% Product Advantages ❯❯Available static pressure ❯❯Simple and reliable ❯❯Choice for sound level ❯❯Integrated condensing control ❯❯EC moteur ❯❯Low consumption 150 DC PF MODEL CAPACITY (1) 14 17 21 24 33 8,8 10,5 12,6 13,7 20,6 1,6 26 3,9 1,9 24 5,2 2,3 15 7,8 2,4 15 7,4 3,7 26 11,1 n. 1 1 1 1 1 m³/h Pa Pa kW A 4900 50 350 0,42 1,6 4900 50 332 0,45 1,6 4900 50 290 0,52 1,6 6400 50 748 0,64 4,3 8000 50 474 1,3 4,3 61,6 61,5 61,5 67,1 72 kW DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) CARACTERISTIQUES COMMUNES ALIMENTATION ELECTRIQUE DIMENSIONS V/ph/Hz 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 Longueur mm Largeur mm Hauteur mm 890 880 900 890 880 900 890 880 900 1190 880 900 1190 880 900 POIDS NET kg 149 154 165 209 224 38 44 58 69 86 CAPACITY (1) kW 24,3 28 31,8 41,9 50 4,3 30 12,7 5 29 19,1 5,7 8 17,5 7,5 18 26,2 9 18 24,5 n. 1 1 2 2 3 m³/h Pa Pa kW A 10000 50 298 1,14 3,6 10000 50 268 1,24 3,6 16000 50 552 2,18 8,6 16000 50 512 2,39 8,6 24000 50 542 3,34 12,9 71,1 71,3 77,3 77,4 80,3 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) CARACTERISTIQUES COMMUNES ALIMENTATION ELECTRIQUE DIMENSIONS V/ph/Hz Longueur mm Largeur mm Hauteur mm 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1390 880 1300 1390 880 1300 1840 880 1300 1840 880 1300 2290 880 1300 314 391 427 520 POIDS NET kg 287 108 114 144 CAPACITY (1) kW 60,3 68,8 89 10,8 10 28 12,3 15 36,7 15,9 31 41,9 n. 4 3 4 m³/h Pa Pa kW A 32000 50 515 4,74 17,2 28000 50 204 5,63 12,9 36000 50 237 7,4 17,2 81,8 83,7 84,5 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1840 880 1800 2290 880 1300 1840 880 1800 631 565 682 1. Gross value – Characteristics referred to entering air at 35°C with hot water inlet temperature 45°C – 20% glycol. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. (*) Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. 151 Plug Fans DC PF 14 / 144 | DC PF LS 85% MODEL CAPACITY (1) 14 17 21 24 33 7,8 9,2 11 12,1 18 1,4 21 3,9 1,7 19 5,2 2 11 7,8 2,2 12 7,4 3,2 21 11,1 n. 1 1 1 1 1 m³/h Pa Pa kW A 4165 50 350 0,28 1,6 4165 50 332 0,3 1,6 4165 50 290 0,34 1,6 5440 50 748 0,42 4,3 6800 50 474 0,83 4,3 57,7 57,6 57,6 63,2 68,1 kW DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 Length mm Width mm Height mm 890 880 900 890 880 900 890 880 900 1190 880 900 1190 880 900 NET WEIGHT kg 149 154 165 209 224 38 44 58 69 86 CAPACITY (1) kW 21,4 24,5 28 36,7 44,3 3,8 24 12,7 4,4 23 19,1 5 6 17,5 6,6 14 26,2 7,9 14 24,5 n. 1 1 2 2 3 m³/h Pa Pa kW A 8500 50 298 0,74 3,6 8500 50 268 0,8 3,6 13600 50 552 1,4 8,6 13600 50 512 1,51 8,6 20400 50 542 2,15 12,9 67,2 67,4 73,4 73,5 76,4 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1390 880 1300 1390 880 1300 1840 880 1300 1840 880 1300 2290 880 1300 314 391 427 520 NET WEIGHT kg 287 108 114 144 CAPACITY (1) kW 53,3 60,4 78,3 9,5 8 28 10,8 12 36,7 14 24 41,9 n. 4 3 4 m³/h Pa Pa kW A 27200 50 515 3,04 17,2 23800 50 204 3,57 12,9 30600 50 237 4,69 17,2 77,9 79,8 80,6 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1840 880 1800 2290 880 1300 1840 880 1800 631 565 682 1. Gross value – Characteristics referred to entering air at 35°C with hot water inlet temperature 45°C – 20% glycol. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. (*) Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. 152 DC PF LS 70% MODEL CAPACITY (1) 14 17 21 24 33 6,8 8 9,3 10,3 15,4 1,2 17 3,9 1,4 15 5,2 1,7 9 7,8 1,9 9 7,4 2,8 16 11,1 n. 1 1 1 1 1 m³/h Pa Pa kW A 3430 50 350 0,17 1,6 3430 50 332 0,19 1,6 3430 50 290 0,21 1,6 4480 50 748 0,26 4,3 5600 50 474 0,5 4,3 53,1 53 53 58,6 63,5 kW DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 Length mm Width mm Height mm 890 880 900 890 880 900 890 880 900 1190 880 900 1190 880 900 NET WEIGHT kg 149 154 165 209 224 38 44 58 69 86 CAPACITY (1) kW 18,3 20,6 23,8 31,1 38,1 3,3 18 12,7 3,7 17 19,1 4,3 5 17,5 5,6 11 26,2 6,8 11 24,5 n. 1 1 2 2 3 m³/h Pa Pa kW A 7000 50 298 0,49 3,6 7000 50 268 0,48 3,6 11200 50 552 0,84 8,6 11200 50 512 0,92 8,6 16800 50 542 1,29 12,9 62,6 62,8 68,8 68,9 71,8 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1390 880 1300 1390 880 1300 1840 880 1300 1840 880 1300 2290 880 1300 314 391 427 520 NET WEIGHT kg 287 108 114 144 CAPACITY (1) kW 45,8 51,4 67 8,2 6 28 9,2 9 36,7 12 19 41,9 n. 4 3 4 m³/h Pa Pa kW A 22400 50 515 1,82 17,2 19600 50 204 2,1 12,9 25200 50 237 2,76 17,2 73,3 75,2 76 DISSIPATION COIL Water flow m³/h Discharge head kPa Water volume l AXIAL FANS Air flow External static pressure Max external static pressure Operating power input Max operating current (FLA) AVERAGE SOUND PRESSURE LEVEL (2) dB(A) COMMON DATA POWER SUPPLY DIMENSIONS V/ph/Hz Length mm Width mm Height mm NET WEIGHT kg 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1840 880 1800 2290 880 1300 1840 880 1800 631 565 682 1. Gross value – Characteristics referred to entering air at 35°C with hot water inlet temperature 45°C – 20% glycol. 2. Average sound pressure level [LPm] 1m far according to ISO EN 3744. (*) Available also with 230/1/50 power supply. Refer to the wiring diagram of the unit. 153 154 General Terms 155 General Terms of sale ARTICLE 1 – Purpose and field of application 1.1. The purpose of these general terms of sale is to define the general provisions applicable to any sale of any good(s) and/or service(s) by an AIRWELL Group company, including but not limited to: AIRWELL FRANCE SAS, AIRWELL INDUSTRIE FRANCE SAS, WESPER INDUSTRIE FRANCE SAS (hereinafter the “Vendor”). 1.2. Equipment shall mean finished good(s), accessory(ies) and spare parts. 1.3. Any order implies full and total acceptance of these general terms of sale. Any condition or clause to the contrary, or general purchasing conditions of the Buyer shall therefore be, in the absence of express written acceptance, non-opposable to the Vendor. Acceptance of these general terms of sale by the Buyer constitutes a material condition without which the Vendor would not have entered into an agreement with the Buyer. 1.4. At any given time, if the Vendor chooses not to act upon any clause of these general terms of sale, this shall not be deemed as a waiver of his future right to act upon these clauses or the general terms of sale. ARTICLE 2 – General points types: catalogues, documentation… 2.1. Due to rapidly changing technology and standards, or security advances in the field concerned, any information, instruction, or value sent by the manufacturer or the Vendor on any support media whatsoever, is provided for information purposes only. The manufacturer or the Vendor reserve the right to make modifications, at any time and without notice, to their apparatus, machines, or machine parts whose prints, photos, or sketches are in its documents. 2.2. When the Vendor chooses the equipment based on information provided by the Buyer, the Vendor shall not be held responsible for errors which may result from inaccurate, vague, or incomplete data. It is still up to the Buyer to ensure that the proposed equipment’s features actually correspond to his requirements, both in terms of performance and implementation feasibility. In addition, if the Buyer requires the collaboration of the Vendor’s freely offered engineers or technicians for a study or project, the Vendor shall not be held liable on any grounds whatsoever. With respect to the aforementioned cases, it is officially agreed that the Vendor shall not be liable, and that the sale shall be concluded at the Buyer’s own risk. The Buyer commits to seek the advice of professionals, both for the choice of equipment and for its implementation. 2.3. The Buyer shall not amend markings affixed on the Equipment or on the packing, nor add any marking, nor make any use of markings, logos and brand which is not expressly authorized by the Vendor. ARTICLE 3 –Orders and quotations 3.1. Orders placed by the Buyer are firm. Once accepted, the order or the quotation shall not be amended or cancelled without Vendor prior and express approval. If a Buyer wholly or partially cancels any order, he shall be held responsible for paying indemnities to the Vendor for the amount of the order cancelled, without prejudice to any other damages. 3.2. The Vendor is not bound by orders placed unless written confirmation has been given by acknowledgement of receipt. The Vendor reserves the right to accept or refuse any order within 10 days of receipt of the order. 3.3. The Buyer shall check the acknowledgement of receipt and notice the Vendor any error or omission within 48 hours maximum from its reception. After this time period, the order is binding for the Buyer. In the event the Buyer makes an order to the Vendor without having paid previous order(s), the Vendor may refuse to honour the order and to deliver the relevant equipment, without Buyer’s possibility to pretend to any indemnity whatsoever. 3.4. Due to the following: deterioration of Buyer’s credit, non-registration of documents and deeds at the commercial court registry, lowering of Buyer’s quote by Vendor’s sales department, refusal by credit insurance to cover the amount of the sales, change or modification in Buyer’s financial or legal capacity, third party rights or claims to Buyer’s funds, and more generally, in the event of a change in Buyer’s situation, the Vendor reserves the right, even after partial fulfillment of an order, to demand 156 guarantees or cancel the order(s) or remaining portion of the order(s) in progress, in the name of the Buyer without any indemnity whatsoever. ARTICLE 4 – Transport and delivery 4.1. The Equipment is deemed delivered “Ex Works” (except as otherwise agreed). The Equipment is delivered at the address mentioned in the acknowledgement receipt. The Vendor shall therefore not be responsible for transport operations. The Buyer agrees to collect the Equipment at the date mentioned in the acknowledgement receipt. The Vendor may make full or spread deliveries. 4.2. The delivery dates are specified as accurately as possible but are given for information only. Delayed deliveries shall not lead to damages, withholding or order cancellation. However, if two (2) months after an unsuccessful injunction the Equipment has not been delivered, for any reason other than a force majeure event, the order may then be cancelled on the request of either of the parties and the Buyer may ask for its instalment to be returned, excluding any further compensation or damages. 4.3. In case of damage occurred during the transport of the Equipment, the Buyer shall notify by recommended letter with acknowledgement of receipt the carrier of such damage within 3 days as from delivery. The Buyer shall immediately send a copy of the letter to the Vendor. If no such provision has been made and no letter has been sent within that time, the relevant Equipment shall be deemed accepted by the Buyer. ARTICLE 5 – Receipt and return of goods 5.1. Any delivery shall be accompanied by a delivery slip. Without prejudice to article 4.3, claims for apparent defects or non-compliance for the delivered Equipment should be sent by registered mail with receipt confirmation to the Vendor’s registered address within three (3) working days after the delivery. Failure to notify within 3 days, the received Equipment shall be deemed compliant with the order and free from defects. The Buyer shall be responsible for providing with its claim any proof of the reality of the defects it could have found to the Vendor. The Buyer shall give the Vendor the possibility to remedy such defects. 157 5.2. In no event shall the Buyer return the Equipment goods without first being allowed to do so in writing by the Vendor. Return costs and risks shall be borne by the Buyer. They shall be borne by the Vendor exclusively in case of apparent defect, or shortage, if confirmed by the Vendor. If a claim is justified, the returned Equipment(s) shall be exchanged, or if it is not possible, shall result in a credit note, without any possibility to ask for compensation or damages for any reason. Any return of Equipment previously accepted will lead to an automatic drop of 20% of the price excluded taxes. Such losses in value include the reconditioning costs or any costs generated by this return. ARTICLE 6 – Warranty – limitation of liabilities 6.1. The contractual warranty is applicable only if the Buyer if fully up-to-date in his payment obligations. 6.2. This warranty does not apply: (i) if problems occur from equipment or spare parts provided by the Buyer or from a design imposed by him; (ii) if the Equipment and/or accessories have been modified by the Buyer or by a third party without Vendor’s written agreement; (iii) to wear parts, consumables and fluid refills, corrosion, and abrasion due to conditions in which Equipment is used that is contrary to Vendor’s specifications, or to the particular use of equipment that was not made known to the Vendor; (iv) if the Equipment is not used and/or maintained in accordance with its original purpose and Vendor’s and/or manufacturer’s instructions; (v) if the Equipment is not installed in rules of art by installer authorized to manipulate refrigerant (vi) in the case of force majeure or exceptional circumstances after equipment has been placed into service as defined as defined hereafter: Except for the payment of money, neither party shall be liable to the other for delays, failures of performance and the like, arising out of acts of God, acts of civil or military authority, fire, strikes, labour disputes or disturbances, floods, epidemics, war, civil strife, riots or delays in transport or due to any other causes similar to the foregoing, beyond its reasonable control. 6.3. Finished goods and spare parts are guaranteed against any defect in material or manufacturing of equipment and parts for one year as of the date of delivery of equipment, unless specific warranty had General Terms of sale been granted for some sideline of equipment to the Buyer. Any procedure underway with respect to contractual warranty shall not prolong the duration of said warranty. 6.4. With respect to the contractual warranty or the warranty for hidden defects, the Vendor’s only obligation shall be, at its choice, to replace or repair, free of charge, the product or item acknowledged as defective by its services. Any Product entitled to the warranty shall first be subjected to the Vendor’s after sales service, whose agreement is required for any replacement; it will first check that the disorder does not result from improper installation or from another fact of the Buyer. Labour expenses for replacement of parts under warranty, as well as transport expenses and consumables, remain at the Buyer’s expense. 6.5. In all cases and for whatever problem encountered, no damages shall be paid for operating losses, property damage, or tangible or intangible losses consequential or not. 6.6. The Vendor undertakes to supply the Buyer with spare parts for a maximum period of 3 years as from delivery of the Equipment, except in the event of agreement to the contrary. ARTICLE 7 – Prices and rebates 7.1. Unless otherwise agreed, prices are Ex Works, and inclusive of packaging as needed, except for special packaging, which is charged extra, according to the terms specified in the Order. Any tax, duty, fee or other charge to be paid shall be borne by the Buyer. 7.2. Prices are those in effect at time of confirmation of order. If the related delivery occurs more than 2 months after confirmation of the order, any modification of price shall immediately apply. 7.3. In the event of early payment compared with the period possibly granted, a discount of 0.50 % per 30-day period shall be granted and deducted from the price initially agreed. 7.4. Except in the event of an agreement to the contrary, the Vendor may grant to the Buyer rebates on the prices in effect at the time of the confirmation of the order, according to the volume of sales net of tax generated annually or during a determined period and/or to the quantity/nature of the products purchased and/or to services eventually rendered by the Buyer. These rebates can be fixed and/ or progressive by tranche of sales generated. The Purchaser can obtain the schedule of rebates in effect by simple request on its part if it has not yet received it from the Vendor. ARTICLE 8 – Term of payment 8.1. Except by express agreement to the contrary, invoices are payable at Vendor’s head office. 100 % of Payment of the price must be made at time of order, except otherwise previously agreed by the parties. In case the Vendor accepts to be paid by (i) bill of exchange or a promissory note, such document have to be returned within a full 8 days after receipt by the Buyer; or by (ii) instalments, the Buyer shall pay on due dates. 8.2. In the event of non-payment on due date or failure to return the bill of exchange within the time given, or of payment by instalments, the non-payment of a single term shall lead to immediate and full payment of sums due by the Buyer to the Vendor, in full right of the law. Any amount not paid by the due date will incur a) late penalty charges owed at right amounting to the European Central Bank’s re-financing rate + 10 points, b) collection fees amounting to at least 40 €. In addition, if a payment is late, (i) the Vendor may suspend all orders in progress or future ones; (ii) he may terminate the contract 48 hours after non-response to formal notice and could request for restitution of the Equipment, in full right of the law without prejudice to any other action and/or damages. The Buyer shall reimburse all expenses caused by the recovery of disputed amounts owed, including legal and lawyer fees, collection agency fees, and in a general sense any amounts paid by the Vendor for recovery. 8.3. Under no circumstances may payments be suspended nor be subject to any compensation without prior written agreement by the Vendor. Any partial payment will first be applied to the nonpreferential debt, and then to the oldest balance. 158 ARTICLE 9 – Retention of title and transfer or risks 9.1. Transfer of ownership of equipment is dependent upon full payment of price by the Buyer. The Buyer agrees to take proper care of the equipment, specifically to insure it against all risks as from its delivery, at its costs. In order to allow any demand from the Seller, the Buyer shall identify and individualize the Equipment. 9.2. In case of resale by the Buyer to a subsequent buyer(s), the Buyer shall inform the subsequent buyer of the Vendor’s retention of title still prevailing over the Equipment. In case of non payment of any invoice on due dates or in case of insolvency of the Buyer, the Vendor will have the right to recover the Equipments, whatever the subsequent buyer is, if any. ARTICLE 10 – Election of jurisdiction – applicable law The present general sales conditions are governed by the French law. Any litigation shall be exclusively submitted to the Tribunal de commerce de Paris, as well for an interim ruling, an ancillary claim, or multiple defendants or third-party claims. THESE GENERAL CONDITIONS ARE IMMEDIATELY AVAILABLE IN LARGE PRINT BY REQUEST. IF THESE CONDITIONS ARE ILLEGIBLE, PLEASE ADVISE US AS THEY ARE AN INTEGRAL PART OF THE VENDOR’S COMMITMENT. 159 160 161 162 163 Airwell France SAS 1 bis avenue du 8 mai 1945 78280 Guyancourt France Tel. +33 (0)1 39 44 78 00 Fax +33 (0)1 39 44 11 55 www.wesper.com 2013 CATCHIGBW001V12013 - The mentioned specifications are subject to change without notice and are not contractual. Airwell France© 2013 - Impression in the U. E.