Power generators
Transcription
Power generators
Power generators 2008 Product Catalog ENDRESS Innovative energy of a strong brand In 94 years of existence, ENDRESS has specialized in the development, construction and sale of first-class power generators. With innovation and new products of technical excellence ENDRESS will set the trend and secure its leading position also in future. The mainstays of the corporate policy are: High performance and reliability due to the choice of outstanding components and standard quality; Environmental compatibility and future-proof technology through in-house development and production; ENDRESS know-how at the company's sites in Germany, Italy, France and Spain. • • • Innovative strength and customized product development as well as professional guidance in application are the parameters of a service-oriented corporate philosophy. In this way, ENDRESS meets the growing requirements and the internationalization of business also in future. This makes ENDRESS so important to power generators: ENDRESS ENDRESS ENDRESS ENDRESS ENDRESS ENDRESS is the leading brand for power generators in Europe. supplies products of all ratings and for all application classes. has passed all safety related tests and holds all awards. has a complete range of accessory items and services with guarantee. offers its partners free professional consultation on product application. maintains a closely knit network of service outlets. Innovation from ENDRESS What you should know about generators Differences in consumers Types of protection 4-7 8 9 Explanations, specifications and what they mean 10 The Professional GT line 2.5 - 12 kVA The ENDRESS generator profile 11 The Professional Plus GT line 4 - 12 kVA 19 - 20 16 - 18 The Silent product line 1.3 - 3.8 kVA 12 - 13 The Duplex line 3 - 13 kVA 21 - 24 The Classic Power line 1.6 - 2.9 kVA 14 - 15 The Silent Power line 5 - 12 kVA 25 - 27 The Diesel Line 3 - 11 kVA 28 - 29 TRIPLEX Technology Emergency generators • • • Manual or automatic supply to the in-house network. Welding generators • Modern petrol or diesel engines. • Robust and sturdy welding generators. • • • Brushless synchronous generator with electronic voltage regulation. Highest protection: IP 54. Maintenance-free for 20,000 generator hours, wear and maintenancefree due to inductive transmission. • OHV engines from HONDA. Site generators • DEUTZ oil/water cooled industrial engines. • Synchronous generators with electronic voltage regulation. Mobile floodlight systems DUPLEX-G5 technology down the engine to the lowest possible • Slows speed in idle running. • Restart at full load from the beginning. • Substantial reduction of noise level in idle running. • Up to 25 % less fuel consumption. Mobile generators • Safe, reliable, long-lived. • Fully hot dip galvanized chassis, turn 360° degs. • Telescopic posts for mechanical or pneumatic extension. Power supply systems • DEUTZ oil/water cooled industrial engines. • VOLVO-Penta water-cooled industrial engines. • Extremely long-lived OHV engines. • Robust, long-lived diesel engines. generator equipment • Site-optimized with compound regulator – 400 V and higher. 3 Generators acc. to DIN 14685 3 - 15 kVA 30 - 35 PTO generators 12 - 55 kVA 46 - 47 Export product line 3.5 - 13 kVA 36 - 37 Engine pumps 600 - 1340 l/min 48 - 49 Emergency generators 6 - 13 kVA 38 - 43 Site generators 13 - 40 kVA 50 - 51 Mobile floodlight systems 52 - 53 Welding line generators 30 - 200 A 44 - 45 2008 Engine pumps DUPLEX-G4 technology Product Catalog • • Corresponds to the VCSF (variable speed constant frequency) technology. Constant voltage and frequency, unrelated to the engine speed. Substantial reduction of pollution and noise emission. Very economical due to low cost of operation. Power supply systems 15 - 600 kVA 54 - 64 Power supply systems Aid to selection Accessory items 65 66 - 68 Mobile generator Accessory items Aid to selection 69 70 - 71 TRIPLEX technology Generator communication Engine communication ENDRESS INNOVATION Analysis of connected consumers 44 26 Made by ENDRESS a success story 1970 1980 1985 1990 Electric and engine welding units from 50 – 240 A Permanently installed and mobile welding generators from 170 – 400 A Permanently installed and noise-controlled large mobile units of 1500 rpm Vertical generators from 1 – 3 kVA Optimal efficiency ENDRESS TRIPLEX technology ENDRESS Efficiency • For global use • Conforms with VSCF (variable speed constant frequency) technology • Constant voltage and frequency - Unrelated to engine speed - The optimal efficiency of the engine is used • Substantial reduction of pollution and noise emission • Very economical due to low cost of operation INNOVATION ENDRESS TRIPLEX technology 55 Speed Future-proof technology with in-house development and production ENDRESS is among the leading European suppliers of power generators. Decades of experience in the development and production of power generators ensure highest quality and absolute reliability. With an output range of up to 2000 kVA, ENDRESS supplies all needs. Innovative units for fire brigades, emergency management and rescue services or the supply of products bound to certain projects are part of the range, as are floodlight systems and emergency power generators. 1997 2000 2006 2007 Generators for fire brigades and emergency rescue services from 3 – 13 kVA Duplex generators from 3 – 13 kVA Silent generators from 6 – 10 kVA Triplex technology from 5 – 30 kVA DUPLEX-G4 generators Powerful tools and circular saws Light and lighting systems M G DUPLEX VKS-Technologie = Verschleißfrei · Kontaktlos S törungsfrei E ENDRESS INNOVATION Site and waste sewage pumps 6 26 PE, inverter or electrode welding units PC and computer processing systems Miniature crane or cement machine DUPLEX = more power from less volume! Powerful like a big unit: compact and handy like a 6 kV frame-mounted unit Where large and heavy units used to work … This is the Duplex difference: In the days where there was no electronics, an asynchronous generator was needed to be able to achieve “smooth” electricity and synchronous generators to tackle “heavy” electricity. With the DUPLEX technology, the electronic control module adapts to the drive engine and responds correspondingly … today, DUPLEX technology proves its competence. before the engine is overloaded. Hidden power reserves can be tapped and the DUPLEX generator “pushes up” even the heaviest inductive consumers and protects even sensitive consumers from damage. In this way all the advantages of asynchronous and synchronous alternators are combined in a single product, and the differences are not needed anymore. The subtle difference Where conventional machines still have carbon brushes, which are subject to wear and tear, the ENDRESS DUPLEX system has an intelligent exciter machine. In combination with the power electronic assemblies, it marks the peak of modern power generation technology. DUPLEX-G5 technology ENDRESS DUPLEX-G5 speed reduction by comparison Full-load phase Idle phase LWA noise reduction Points for the DUPLEX-G5 technology • Slows down the engine to the lowest possible speed in idle running. • Restarts at full load from the beginning. • Substantial reduction of noise level in idle running. • Up to 25 % less fuel consumption. • Less emission of pollutants. • Life is extended several times over. Full-load phase Recovery phaseWaiting time (competitor) mechanical/manual speed reduction ENDRESS DUPLEX-G5 speed reduction ENDRESS DUPLEX-G5 technology Competitor Recovery phase – Waiting time (competitor) The new E-MSC 3.0 at a glance The perfect Multifunction Control System (MSC) from ENDRESS. A system for optimal safety and user friendliness for everyday use. CanBus capability included as standard. Icon Run hours Function Total run hours of the engine/generator Display LED P icon Load Function Phases 1-3 load Display LED Green = 0 to 80% Yellow = 81 to 100% Red = 101 to 110% Option: CanBus linkup The link between the unit and the customer’s operator panel is provided by a control interface unit (CIU). Before data can be exchanged, some customization must be made at the ENDRESS factory. Icon Ambient temperature1 Function Measures the direct ambient temperature Display LED Red = Ambient temperature too high Icon Engine temperature1 Function Measures the engine temperature Display LED Red = Engine temperature too high Icon Oil pressure Function Measures the oil pressure Display LED Red = Oil pressure fault Icon Fuel temperature1 Function Measures the fuel temperature Display LED Red = Fuel temperature too high Icon Rotating field Function Status of the rotating field (cw or ccw) Display LED Red blinking = ccw rotation Icon Emergency stop Function Emergency stop enabled Display LED Red = Emergency stop has been pressed Icon Battery charge indicator Function Charge function of the alternator has failed Display LED Red = Fault P icon Phase voltage Function Indicates voltage of phases 1-3 Display LEDs Red = high (undervoltage) Green = voltage OK Red = low (overvoltage) Icon Iso3 Function Isolation fault Display LED Yellow = Half fault Red = Fault Icon Protective conductor check Function Protective conductor of the connected unit is checked Display LED Green = OK Icon L1 = Phase 1 L2 = Phase 2 L3 = Phase 3 Icon Frequency Function Frequency of generated voltage Display LED Red = high (frequency too high) Yellow = 47 - 53 Hz (frequency OK) Red = low (frequency too low) Icon Tank2 Function Level indication Display LED Green = Tank (full) Yellow = Tank (half full) Red = Tank (reserve) 1 2 3 Option - Warning signal package II (ambient, engine and fuel temperature functions only available as a set) Option - Fuel indicator, incl. fuel sensor ISO function only with fitted isometer INNOVATION r.p.m phase uction d red Spee Most generators do not run at constant load all the time but there are times of idling in between. Power is withdrawn as and when needed, such as when power tools are used. Today it is important to have power available on call. ENDRESS Why speed reduction? 7 What you should know about generators Verify prior to any start-up that the overall output of the unit to be connected does not exceed that of the nominal continuous output of the generator. The required information can be found on the nameplate or in the product booklet of the consumer. GENERATORS I N F O R M AT I O N Types of engines Petrol engines should be considered when the mobile generator should be small and must only run for short periods at intermittent occasions. Diesel engines are heavier and more robust and therefore better for long run hours. Diesel engines have lower specific consumption. When to use a high-speed and when a low-speed engine? The correct decision. High-speed engine (OHV petrol and diesel engines of 3000 rpm) Engines for daily operation of 4 - 10 hours. Life = service life between 3000 and 5000 hrs. (e.g., building sites, craft businesses) • Low-speed engines (diesel engines of 1500 rpm) Engines for round-the-clock service Life = service life between 10000 and 20000 hrs. (e.g., electricity and emergency generators) • Start-up system A distinction is generally made between two types of start-up systems: 1. Recoil starter to crank the engine manually via a strong pull of an automatic wind-up rope. 2. Electric starter via ignition. At a glance Performance data often indicate the maximum output of the engine without load on the crankshaft = SAE HP, usually at 3600 rpm. For electrotechnical reasons all high-speed engines must run at 3000 rpm. Hence, the output is lower even if no load is connected. Therefore: Rely only on performance data that relate to 3000 rpm. 8 Rule of thumb: 1 HP engine output supplies maximum 0.5 kVA generator output (50%) 1 kW engine output supplies maximum 0.65 kVA generator output (65%) Synchronous or asynchronous generators: The generator makes the difference. A system comparison. Application Synchronous Asynchronous All ohmic and inductive consumers. Only ohmic consumers without restrictions. Inductive consumers with considerable restrictions. Start up reaction Unproblematic start up reaction, irrespective of the consumer. Problematic start up reaction with consumers which are difficult Compound regulatored alternators with 3 times the start up current. to start, particularly with alternators which do not have a Duplex alternators with 4 times the start up current. strengthened start up. A large generator is required for alternators with a strengthened start up. Loading capacity The alternator can also be loaded up to 100% by inductive consumers and can therefore be smaller. The alternator can only be loaded up to 1/3 (without strengthened start up) and 2/3 (with strengthened start up) by inductive consumers. Mechanical regulator IP23. Electronic regulator IP54. Normally unregulated, capacitor. Determined by internal cooler IP 23. Determined by external cooler IP 54. Determined by the external cooler IP 54. Regulator Type of protection Protective measures Fuse disconnections as protection for user. RCD protection switch not necessary. Fuse disconnections as protection for user. RCD protection switch not necessary. Differences in consumers Ohmic consumers Inductive consumers In this case, the consumers concerned are machines which do not require any start up current, i.e., consumers whose power consumption does not increase up to the normal operating condition in the moment of ignition. Start-up current = operating current. The consumption data of these machines can be used without making any additions. In this case, the consumers concerned are machines which require a multiplicity of power indicated only for a short time during the moment of starting. * GENERATORS * I N F O R M AT I O N * Particularly electric motors require 2-6 times the given value for the build up of the magnetic field as well as for the acceleration to the working speed. * * Universal motors which are mostly active power load consumers 9 Types of protection Why are they so important? IP = International protection according to DIN 40050 60° Electrical machines must be protected from moisture and dirt to be able to function properly. ENDRESS generators work to the protection measure/protection separation VDE 0100. The protection separation divides the supply line of a connected unit from the storing network. In this way a situation of a closed electric circuit can be prevented by the ground. Therefore the installation of grounding can be avoided. The IP code is a two-digit number which indicates the type of protection. The first digit specifies the protection class for shock and ingress of solid foreign bodies, the second digit indicates the protection against water and moisture. IP 23 IP 54 0 1 2 3 4 5 Unprotected Foreign bodies > 50 mm Foreign bodies > 12 mm Foreign bodies > 2.5 mm Foreign bodies > 2.5 mm Protected against dust 0 Unprotected 1 Vertical dripping 2 Dripping at up to 15° from vertical 3 Water spray at up to 60° from vertical 4 Splash water from all directions 5 Hose water from all directions Explanations, Specifications and what they mean Explanation of the abbreviations in the tables GENERATORS I N F O R M AT I O N V = Volts Hz = Hertz A = Ampere W = Watt (x 1000 = kW) VA = Volt x Amperes (x 1000 = kVA) Cos phi = Physical power factor 10 26 Voltage (230/400/115) Frequency (50/60) Amperage Active power Power factor Power factor (0.8 - 1) Apparent power - indicated in units of VA or kVA This is the power the generator can produce. Active power - indicated in units of W or kW This is the power the generator can supply, depending on the generator's power factor. Reactive power This is the difference between active power and apparent power. It provides the required start-up current - moves between generator and consumer to build up the magnetic field. Most ENDRESS generators comply with EC directive 2000/14/EC. Generators which do not comply with that directive are marked “Not for EC countries”. Unit dB(A) dB = Decibel (A) = Filter COP = Continuous power of the unit Continuous power in full power application without a time limit. PRP = Variable continuous power of the unit Continuous power in a varying load operation (average 80% load within 24 hrs.) without time limit. LTP = Limited time unit power A maximum power which can be applied for a maximum of 500 hours per year, whereby in a variable load operation 300 hours should not be exceeded. LP sound pressure level L = Level (measured value) P = Pressure LWA sound power level L = Level (measured value) W = Watt (power) A = Filter RCD Insulation monitoring The RCD, also named grounding or short circuit switch, is one of the most widely used electrical safety elements that protects the user from electrically loaded components if he should accidentally touch them. The electricity supply will be automatically cut off as soon as there is a loss of power towards the ground wire, e.g. from a faulty conductor. Correct grounding, to which all earth conductors of the unit are connected, is a prerequisite for the perfect functioning of the RCD. ENDRESS ISO makes a so-called “built grounding” unnecessary, whatever the bedding might be. Furthermore the “calibration” of this protective measure may be dispensed with. Hence operation becomes possible at any workplace without any further preparations. In addition high resistance insulation defects are reliably detected and automatically cause the voltage to be switched off. ENDRESS type code ESE 504 SDYS-GT ES ISO DIN Diesel Silent = = = = = with silencer acc. to DIN 14658 insulation monitored electric starting large tank S = Synchronous generator IP 23 T = TRIPLEX G = DUPLEX G4/G5 IP54 Y = YANMAR D = B = BRIGGS & STRATTON V = H = HONDA petrol R = HATZ diesel D = 3-phase current 400 V 3 ph. S = Welding generator 2 = Base frame 4 = Frame unit 6 = Large tank 8 = Noise cover = Output rating = ENDRESS GENERATOR DEUTZ VOLVO RUGGERINI AC E M TRIPLEX G Synchronous generator Duplex-G4 generator Triplex technology • • • • • • • • • • • with VSCF technology. • Conforms voltage and frequency unrelated to • Constant engine speed. reduction of pollution and noise • Substantial emission. economical due to low cost of operation. • Very • Smaller and with higher output. Class of protection IP 23 against water spray. Maintenance-free. Can withstand start-up current for a short time. Compound-controlled high-performance generator suitable for 3 times overload from 400 V. Smooth voltage shape. Brushless synchronous generator IP 54, with electronic voltage regulation. Start-up performance 60% higher than conventional generators. 100% constant voltage in spite of varying speed. Suitable for 200% load unbalance. 20000 generator hours. VKS technology. GENERATOR PROFILE M G G E Duplex-G5 technology down the engine to the lowest possible • Slows speed in idle running. at full load from the beginning. • Restarts reduction of noise level in idle run• Substantial ning. • Up to 25 % less fuel consumption. ENDRESS M DUPLEX The ENDRESS generator profile 11 Engine or diesel. • Petrol starting by recoil starter. • Easy OHV design. • Modern Less petrol consumption. Less oil consumption. oil cutoff. • Low transistor ignition. • Contactless • Simple handling. Monobloc tube frame protection of engine and transmission. • Optimal 4 fold-out • Tool box. carrying handles. • Strong steel tube. • Bearings in vibration absorbing Silent block • Supported bearings. Socket outlets water protected socket outlets • Splash with neutral conductor. socket outlet for 230 V. • CEE • CEE socket outlet for 400 V, 5-pin. SILENT-LINE G E N E R AT O R S Silent Line generators 1.3 - 3.8 kVA 12 The concept of the future in the mobile generator market: compact, lightweight, low noise, powerful… …and suitable for all applications. Most advanced generator technology supplies highest output and current whose quality compares to that of the public mains. The intelligent engine management controls the engine speed as function of the load which reduces fuel consumption and noise. Constant power output is a particular advantage for electronic consumers and consumers with start-up current. • TRIPLEX technology. • Intelligent engine management. • Constant power output. • Stable and exact parameters. • Low-noise and economical. • Easy starting with most advanced • • • • engine technology. Light-weight and compact. Long service life. Simple and safe to handle. Complies with all norms. Mobile power generation on highest level. For boats, camping and events, high cost effectiveness. SILENT-LINE G E N E R AT O R S ESE 3500 T Silent ESE 4500 T Silent E ESE 2000 T Silent M Type ESE 2000 T Silent ESE 3500 T Silent ESE 4500 T Silent Order No. 110 000 110 001 110 002 Alternator synchronous synchronous synchronous Max. output [LTP] kVA/kW 1,65/1,65 3,2/3,2 4,3/4,3 Constant rating [COP] kVA/kW 1,35/1,35 2,8/2,8 3,8/3,8 Nominal voltage 230 V 1~/12 V = 230 V 1~/12 V = 230 V 1~/12 V = Nominal current/cos (phi) 5,8 A 1~/8,3 A =/1 12,1 A 1~/8,3 A =/1 16,5 A 1~/8,3 A =/1 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 Voltage regulation electronic electronic electronic Engine type ROBIN EH09 ROBIN EX21 ROBIN EX27 Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke 1-cyl. 4-stroke Engine capacity 86 cm3 212 cm3 265 cm3 Max. output 2,1 kW/2,9 HP 5,1 kW/7 HP 6,6 kW/9 HP Fuel/Tank capacity (litres) Unleaded petrol/4 Unleaded petrol/10,8 Unleaded petrol/12,8 Consumption/Running-time1 0,7 l/6 h 1,4 l/6,5 h 1,8 l/7 h Start-up system Recoil E-start incl. battery E-start incl. battery Sound power level LWA2 90 dB(A) 91 dB(A) 91 dB(A) Sound pressure level LPA3 65 dB(A) 66 dB(A) 66 dB(A) Weight kg 21 59 74 Dimensions L x W x H in mm 490 x 295 x 445 537 x 482 x 583 580 x 527 x 618 Outfit Shockproof sockets 2 x 230 V/16 A 2 x 230 V/16 A 2 x 230 V/16 A Operating control lamps Digital display Digital display Cut-off when lack of oil, load-dependent engine speed, overload protection, connection for 12 V battery charge Application areas* 230 V 230 V 230 V Appliances up to 1350 W 2800 W 3800 W PC/Multimedia up to 1350 W 2800 W 3800 W Electric tools up to 1200 W 2600 W 3600 W Gardening equipment up to 1000 W 1900 W 2500 W 1400 W 1900 W Construction equipment up to 1 2 * Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. TRIPLEX G 13 G E N E R AT O R S CLASSIC POWER-LINE Classic Power Line generators 1.6 - 2.9 kVA 14 18 26 ESE 30 BS All-round generators for electrical equipment, power tools, gardening equipment and lighting. The portable ENDRESS generators of this type series are equipped with HONDA engines as well as with high-performance synchronous generators. A sturdy monobloc tube frame with large side panels protects engine and generator (except ESE 20 BS). Low oil cut-off and overload protection belong to standard outfit. G E N E R AT O R S ESE 20 BS CLASSIC POWER-LINE Classic Power-Line quality generators, which convince in performance and price. ESE 3000 ESE 40 BS Available accessories Set of wheels Order No. 161 000 Type ESE 20 BS ESE 30 BS ESE 35 BS ESE 40 BS Order No. 230 001 45 900-P 230 004 45 9800-FP 210 002 Alternator synchronous synchronous synchronous synchronous synchronous Max. output [LTP] kVA/kW 15 except for ESE 20 BS, ESE 3000 ESE 3000 2,1/1,9 2,5/2,2 3,0/2,7 3,4/3,1 2,8/2,6 Constant rating [COP] kVA/kW 1,6/1,5 2,0/1,8 2,4/2,1 2,9/2,6 2,4/2,2 Nominal voltage 230 V 1~ 230 V 1~ 230 V 1~ 230 V 1~ 230 V 1~/12 V Nominal current 6,5 A 1~/0,9 8,7 A 1~/0,9 10,3 A 1~/0,9 12,5 A 1~/0,9 10,4 A 1~/10 A =/0,9 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 Engine type HONDA GC 135 HONDA GC 160 HONDA GC 190 HONDA GX 200 HONDA GX 160 Version 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV Engine capacity 135 cm3 160 cm3 187 cm3 196 cm3 163 cm3 Max. output 2,7 kW/3,7 HP 3,2 kW/4,4 HP 4,4 kW/5,9 HP 4,3 kW/5,8 HP 3,6 kW/4,9 HP Fuel/Tank capacity (litres) Unleaded petrol/1,7 Unleaded petrol/2 Unleaded petrol/2 Unleaded petrol/11 Unleaded petrol/11 Consumption/Running-time1 0,7 l/2,5 h 0,8 l/2,5 h 1 l/2 h 1,1 l/10 h 0,9 l/12 h Start-up system Recoil Recoil Recoil Recoil Recoil Sound power level LWA2 94 dB(A) 95 dB(A) 96 dB(A) 96 dB(A) 93 dB(A) Sound pressure level LPA3 69 dB(A) 70 dB(A) 71 dB(A) 71 dB(A) 68 dB(A) Weight kg 20 33 34 42 43 Dimensions L x W x H in mm 492 x 355 x 390 640 x 455 x 400 640 x 455 x 400 620 x 405 x 500 620 x 405 x 400 2 x 230 V/16 A 2 x 230 V/16 A 2 x 230 V/16 A 2 x 230 V/16 A 230 V Outfit Shockproof sockets 1 x 230 V/16 A Cut-off when lack of oil, overload protection Application areas* 230 V 230 V 230 V 230 V Electric tools up to 1400 W 1700 W 2000 W 2500 W 2100 W Construction equipment up to 1000 W 1200 W 1400 W 1700 W 1500 W 1000 W 1300 W 1100 W Compressors or pumps up to 1 2 * Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. G E N E R AT O R S PROFESSIONAL-GT-LINE Professional GT Line generators 2.5 - 7 kVA 16 Type ESE 206 HS-GT Order No. 112 000 112 011 Alternator synchronous synchronous Max. output [LTP] kVA/kW 2,9/2,6 Constant rating [COP] kVA/kW 2,45/2,2 ESE 206 HS-GT • HONDA OHV engines. • Compound regulator at 400 V. • Thermo protection switch. • Low oil cut-off. • Robust monobloc tube frame. • 11-18 liter tank for long run hours. 3,4/3,1 2,9/2,6 Nominal voltage 230 V 1~ 230 V 1~ Nominal current 10,6 A 1~ 12,5 A 1~ Power factor cos (phi) 0,9 0,9 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 Engine type HONDA GX 160 HONDA GX 200 Engine version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV Engine capacity 163 cm3 196 cm3 Max. output 3,6 kW/4,9 HP 4,3 kW/5,8 HP Fuel/Tank capacity (litres) Unleaded petrol/11 Unleaded petrol/11 Running-time at ¾ load approx.1 The Professional GT Line excels in the high standard of quality, reliability and long service life. ESE 306 HS-GT 0,9 l/12 h Start-up system Recoil Recoil Sound power level LWA2 96 dB(A) 96 dB(A) Sound pressure level LPA3 71 dB(A) 71 dB(A) Weight kg 42 44 Dimensions L x W x H in mm 623 x 409 x 500 623 x 409 x 500 Outfit 2 x 230 V/16 A 2 x 230 V/16 A Shockproof sockets Cut-off when lack of oil, overload protection Application areas* 230 V 230 V Electric tools up to 2100 W 2500 W Construction equipment up to 1500 W 1700 W 1300 W 1300 W Inverter welding machines up to Compressors, pumps up to 1 2 * Consumption/litres in hours, running-time in hours. These indications are based on approx. values Sound level indication according to the directive for noise emission law 2000/14/EG. As the power needs of each consumer are influenced by various factors, no claims can be derived For demanding users. Mature technology and solid construction: the Professional GT line G E N E R AT O R S PROFESSIONAL-GT-LINE ESE 606 HS-GT ESE 506 DHS-GT Options Set of wheels Crane loading device Order No. 161 000 all types 161 103 except for ESE 206 HS-GT, ESE 306 HS-GT carrying handles, fold-out (4 pcs.) 161 002 all types ESE 406 HS-GT ESE 506 DHS-GT ESE 406 HS-GT ES ESE 606 HS-GT ESE 606 DHS-GT ESE 606 DHS-GT ESE 606 DHS-GT ES 112 001 112 009 112 003 112 002 112 004 112 008 synchronous synchronous synchronous synchronous synchronous synchronous 5,1/4,6 5,1/4,6 6,3/5,0 4,2/3,7 7,2/6,4 8,3/6,6 5,5/4,9 8,3/6,6 5,5/4,9 4,2/3,9 4,2/3,9 5,4/4,3 3,1/2,8 6,0/5,4 7,0/5,6 4,1/3,7 7,0/5,6 4,1/3,7 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 18,3 A 1~ 18,3 A 1~ 7,7 A 3~ 13,5 A 1~ 26,1 A 1~ 10,1 A 3~ 17,8 A 1~ 10,1 A 3~ 17,8 A 1~ 0,9 0,9 0,8 0,9 0,9 0,8 0,9 0,8 0,9 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 HONDA GX 270 HONDA GX 270 HONDA GX 270 HONDA GX 390 HONDA GX 390 HONDA GX 390 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 270 cm3 270 cm3 270 cm3 389 cm3 389 cm3 389 cm3 6,3 kW/8,6 HP 6,3 kW/8,6 HP 6,3 kW/8,6 HP 8,3 kW/11,3 HP 8,3 kW/11,3 HP 8,3 kW/11,3 HP Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18 1,1 l/10 h 1,6 l/11 h 1,6 l/11 h Recoil E-start incl. battery Recoil Recoil Recoil E-start incl. battery 97 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 62 66 76 74 82 90 832 x 513 x 570 832 x 513 x 570 832 x 513 x 570 832 x 513 x 570 832 x 513 x 570 832 x 513 x 570 2 x 230 V/16 A 2 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A 1 x CEE400 V/16 A 1,6 l/11 h 2,2 l/8 h 2,1 l/8,5 h 2,1 l/8,5 h 230 V 230 V 400 V 230 V 230 V 400 V 230 V 400 V 230 V 3800 W 3800 W 4200 W 2700 W 5300 W 5500 W 3600 W 5500 W 3600 W 2600 W 2600 W 2900 W 1900 W 3600 W 3700 W 2500 W 3700 W 2500 W 2,5 mm 2000 W at ¾ load and therefore without obligation. 3 Sound pressure level at distance of 7 m. from this table. 2000 W 2200 W 3,25 mm 1400 W 2800 W 2800 W 3,25 mm 1900 W 2800 W 1900 W 17 G E N E R AT O R S PROFESSIONAL-GT-LINE Professional GT Line generators 10 - 12 kVA These “power packs” provide maximum performance and reliability. Compact design and best craftsmanship for harsh professional duty. • HONDA 2-cylinder OHV engines. • B & S V-Twin 2-cylinder OHV engines. • Thermo protection switch. • Low oil cut-off. • High-performance synchronous generators. • Robust monobloc tube frame with side panels • • Available accessories Set of wheels Set of wheels Crane loading device Order No. 161 000 161 007 161 104 for type series ESE 1006 for type series ESE 1206 for type series ESE 1206 NEW 18 for perfect dust and weather protection. 16 - 24 liter tank for long run hours. Compound regulator at 400 V. NEW Type ESE 1006 DBS-GT ESE 1006 DBS-GT ES ESE 1206 HS-GT ES Order No. 112 023 112 024 112 021 ESE 1206 DHS-GT ES 112 022 Alternator synchronous synchronous synchronous synchronous Max. output [LTP] kVA/kW 11,0/8,8 6,6/5,9 11,0/8,8 6,6/5,9 11,9/10,7 13,9/11,1 9,2/8,3 Constant rating [COP] kVA/kW 10,0/8,0 6,0/5,4 10,0/8,0 6,0/5,4 10,0/9,1 11,8/9,4 6,9/6,2 Nominal voltage 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 14,4 A 3~ 26,0 A 1~ 14,5 A 3~ 26,1 A 1~ 43,5 A 1~ 17 A 3~ 30 A 1~ Power factors cos (phi) 0,8 0,9 0,8 0,9 0,9 0,9 0,8 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 Engine type B & S V-Twin B & S V-Twin HONDA GX 620 HONDA GX 620 Engine version 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV Engine capacity 570 cm3 570 cm3 614 cm3 614 cm3 Max. output 12,0 kW/16,3 HP 12,0 kW/16,3 HP 13,5 kW/18,4 HP 13,5 kW/18,4 HP Fuel/Tank capacity (litres) Unleaded petrol/16 Unleaded petrol/16 Unleaded petrol/24 Unleaded petrol/24 Running-time at ¾ load approx.1 2,9 l/5 h 2,9 l/5 h 3,5 l/7 h 3,5 l/7 h Start-up system Recoil E-start incl. battery E-start incl. battery E-start incl. battery Sound power level LWA2 97 dB(A) 97 dB(A) 96 dB(A) 96 dB(A) Sound pressure level LPA3 72 dB(A) 72 dB(A) 71 dB(A) 71 dB(A) Weight kg 110 115 170 175 Dimensions L x W x H in mm 945 x 570 x 640 945 x 570 x 640 960 x 638 x 664 960 x 638 x 664 Outfit 2 x 230 V/16 A 2 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A Shockproof sockets 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 2 x CEE 230 V/16 A Handles, fold-out Handles, fold-out 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A Cut-off when lack of oil, overload protection Application areas* 400 V 230 V 400 V 230 V 230 V 400 V Electric tools up to 7900 W 5300 W 7900 W 5300 W 9000 W 9300 W 6100 W Construction equipment up to 5300 W 3600 W 5300 W 3600 W 6000 W 6200 W 4100 W 2500 W 3700 W 2500 W 4500 W 4700 W Inverter welding sets up to 4,5 mm Compressors or pumps up to 3700 W 1 2 * 4,5 mm 230 V 5,0 mm Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. 3100 W G E N E R AT O R S PROFESSIONAL-GT-LINE Professional Plus GT Line generators 4 - 5.4 kVA High-quality design plus extra outfit are typical of this series. Points for the Professional Plus GT line: Isometer. Voltmeter. Run hour meter. Large tank. Thermal overload protection. HONDA OHV engines. Compound regulator at 400 V. • • • • • • • Type ESE 506 HS-GT ES ISO ESE 506 DHS-GT ES ISO Order No. 112 013 112 006 Alternator synchronous synchronous Max. output [LTP] kVA/kW 5,3/4,8 6,3/5,0 4,2/3,7 Constant rating [COP] kVA/kW 4,1/3,7 5,4/4,3 3,1/2,8 Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 17,8 A 1~ 7,7 A 3~ 13,5 A 1~ Power factor cos (phi) 0,9 0,8 0,9 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 Engine type HONDA GX 270 HONDA GX 270 Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV Engine capacity 270 cm3 270 cm3 Max. output 6,3 kW/8,6 HP 6,3 kW/8,6 HP Fuel/Tank capacity (litres) Unleaded petrol/18 Unleaded petrol/18 Consumption/Running-time1 1,6 l/11 h 1,6 l/11 h Start-up system E-start incl. battery E-start incl. battery Sound power level LWA2 97 dB(A) 97 dB(A) Sound pressure level LPA3 72 dB(A) 72 dB(A) Weight kg 79 88 Dimensions L x W x H in mm 832 x 513 x 570 832 x 513 x 570 Outfit 1 x 230 V/16 A 1 x 230 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A Shockproof sockets Cut-off when lack of oil, overload protection, voltmeter, operating hour meter, isometer Application areas* 230 V 400 V 230 V Electric tools up to 3600 W 4200 W 2700 W Construction equipment up to 2400 W 2900 W 1900 W Inverter welding up to Compressors or pumps up to 1 2 * 2,5 mm 1900 W 2200 W 1400 W Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. 19 PROFESSIONAL-PLUS-GT-LINE G E N E R AT O R S 20 Professional Plus GT Line generators 6 - 12 kVA Note on insulation monitoring: The insulation monitoring is a major contribution to improving electrical safety and makes the application of this unit possible in damp places such as ducts and shafts, and in areas in which suitable grounding for the generator cannot be produced. The isometer provides highest safety during electric fault and stops the voltage supply instantly. Made for harsh professional duty. ESE 606 DHS-GT ES ISO Available accessories Set of wheels Set of wheels Crane loading device Crane loading device Order No. 161 000 161 007 161 103 163 104 for for for for type type type type series series series series ESE ESE ESE ESE 506, ESE 606 1206 506, ESE 606 1206 ESE 1206 HS-GT ES ISO Type ESE 606 HS-GT ES ISO ESE 606 DHS-GT ES ISO ESE 1206 HS-GT ES ISO ESE 1206 DHS-GT ES ISO Order No. 112 019 112 007 112 016 112 017 Alternator synchronous synchronous synchronous synchronous Max. output [LTP] kVA/kW 7,1/6,4 8,3/6,6 5,5/4,9 11,9/10,7 13,9/11,1 9,2/8,3 Constant rating [COP] kVA/kW 6,0/5,4 7,0/5,6 4,1/3,7 10,0/9,1 11,8/9,4 6,9/6,2 Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 26,1 A 1~ 10,1 A 3~ 17,8 A 1~ 43,5 A 1~ 17 A 3~ 30 A 1~ Power factor cos (phi) 0,9 0,8 0,9 0,9 0,9 0,8 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 Engine type HONDA GX 390 HONDA GX 390 HONDA GX 620 HONDA GX 620 Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV Engine capacity 389 cm3 389 cm3 614 cm3 614 cm3 Max. output 8,3 kW/11,3 HP 8,3 kW/11,3 HP 13,5 kW/18,4 HP 13,5 kW/18,4 HP Fuel/Tank capacity (litres) Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/24 Unleaded petrol/24 Consumption/Running-time1 2,1 l/8,5 h 2,1 l/8,5 h 3,5 l/7 h 3,5 l/7 h Start-up system E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery Sound power level LWA2 97 dB(A) 97 dB(A) 96 dB(A) 96 dB(A) Sound pressure level LPA3 72 dB(A) 72 dB(A) 71 dB(A) 71 dB(A) Weight kg 91 96 170 176 Dimensions L x W x H in mm 832 x 513 x 570 832 x 513 x 570 960 x 638 x 664 960 x 638 x 664 Outfit 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A Shockproof sockets 1 x CEE230 V/32 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A Cut-off when lack of oil, overload protection, voltmeter, operating hour meter, isometer Application areas* 230 V 400 V 230 V 230 V 400 V Electric tools up to 5300 W 5500 W 3600 W 9000 W 9300 W 6100 W Construction equipment up to 3600 W 3700 W 2500 W 6000 W 6200 W 4100 W 1900 W 4500 W Inverter welding machines up to 3,25 mm Compressors or pumps up to 2800 W 1 2 * 2800 W 230 V 5,0 mm Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. 4700 W 3100 W Duplex Line generators 3 - 13 kVA Where large and heavy units used to work, today DUPLEX technology proves its competence. • PE and inverter welding units. • Electrode welding units. • PC and computer processing systems. • Lights and lighting systems. • Complete power delivery in three • • phase and alternating current with different consumers. Powerful electric tools as well as pumps and circular saws. Miniature cranes, cement machine. STOP! One generator for all applications! Why lower speed? Most generators do not run at constant load all the time but there are times of idling in between. Power is withdrawn as and when needed, such as when power tools are used. Today it is important to have power available on call. Points for the DUPLEXS-G5 technology • Slows down the engine to the lowest possible speed in idle running. • Restarts at full load from the beginning. • Substantial reduction of noise level in idle running. • Up to 25 % less fuel consumption. • Less emission of pollutants. • Life is extended several times over. DUPLEX-LINE Due to its advantages, the brushless synchronous generator IP 54 (4-fold starting current) can pick up the load peaks of individual consumers, such as electric machines which are difficult to start up (cement machines), and at the same time operate electronic consumers (PE welding unit). G E N E R AT O R S Exemplary and trend-setting in quality, technology and outfit. 21 Duplex Line generators DUPLEX-LINE G E N E R AT O R S Modern and more powerful consumers need more output from mobile generators. The development of such units is governed by customer and market demands. Therefore, we constantly add new versions to our product lines. The new DUPLEX generators set new standards in precision and reliability. • Optimal operating comfort with new • • ESE 604 DHG DUPLEX ESE 304 HG DUPLEX • Available accessories Set of wheels Set of wheels Crane loading device Refuelling system Exhaust pipe Order No. 161 000 161 015 E 130 265 163 110 163 120 for for for for for ESE ESE ESE ESE ESE control panel. Larger tank for longer run time - 20 liters. New place for the tank for less heating, less sensitive to temperature. Improved tank opening, higher filler neck. 604 DHG, ESE 604 DHG ES Diesel 606, ESE 1006, ESE 1306 DBG ES Duplex 604 DHG, ESE 604 DHG ES Diesel 606, ESE 1006, ESE 1306 DBG ES Duplex 606, ESE 1006, ESE 1306 DBG ES Duplex NEW 22 NEW Type ESE 304 HG Duplex ESE 604 DHG Duplex ESE 606 DBG Duplex Order No. 113 012 113 000 113 002 113 003 Alternator/Duplex-G4 synchronous synchronous synchronous synchronous Max. output [LTP] kVA/kW 3,3/2,6 6,6/5,3 4,4/4,0 6,6/5,3 4,4/4,0 6,6/5,3 4,4/4,0 Constant rating [COP] kVA/kW 3,0/2,4 6,0/4,8 4,0/3,6 6,0/4,8 4,0/3,6 6,0/4,8 4,0/3,6 Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 13 A 1~ 8,7 A 3~ 18,0 A 1~ 8,7 A 3~ 18,0 A 1~ 8,7 A 3~ 18,0 A 1~ Power factor cos (phi) 0,9 0,8 0,9 0,8 0,9 0,8 0,9 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 Voltage regulation electronic electronic electronic electronic Engine type HONDA GX 200 HONDA GX 390 B & S V-Twin B & S V-Twin Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV Engine capacity 196 cm3 389 cm3 480 cm3 480 cm3 Max. output [LTP] kVA/kW 4,3 kW/5,8 HP 8,3 kW/11,3 HP 7,5 kW/10,2 HP 7,5 kW/10,2 HP Fuel/Tank capacity (litres) Unleaded petrol/3,6 Unleaded petrol/6,5 Unleaded petrol/20 Unleaded petrol/20 Consumption/Running-time1 1,2 l/3 h 2,1 l/3 h 2,4 l/8 h 2,4 l/8 h Start-up system Recoil Recoil Recoil E-start incl. battery Sound power level LWA2 96 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) Sound pressure level LPA3 71 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) Weight kg 53 100 117 120 Dimensions L x W x H in mm 555 x 405 x 445 820 x 495 x 570 870 x 562 x 640 870 x 562 x 640 Outfit 2 x 230 V/16 A 3 x 230 V/16 A 3 x 230 V/16 A 3 x 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A Shockproof sockets ESE 606 DBG ES Duplex Cut-off when lack of oil (except for ESE 604 DHG ES Diesel), overload protection, start-stop system (types with E-start), handles (except Application areas* 230 V 400 V 230 V 400 V 230 V 400 V 230 V Electronic loads up to 2400 W 4800 W 3600 W 4800 W 3600 W 4800 W 3600 W Electric tools up to 2300 W 4700 W 3500 W 4700 W 3500 W 4700 W 3500 W Construction equipment up to 1600 W 3200 W 2400 W 3200 W 2400 W 3200 W 2400 W Inverter welding machines Compressors or pumps 1 2 * 3,25 mm 1100 W 2200 W 3,25 mm 1700 W 2200 W Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. 3,25 mm 1700 W 2200 W 1700 W Options - not retrofit 3-way fuel cock for ext. refuelling Duplex G5/Idle-down automatic Automatik Choke Automatik Choke Isometer Cable Remote control (50 m) Remote remole control Multifunctional-Control-System E-MCS 3.0 Detailed description you find on page 7 Warning signal kit fuel gauge incl. fuel level sensor NEW Order No. 162 005 163 020 163 030 163 031 010 043 162 006 162 007 162 311 for ESE 606, ESE 1006, ESE 1306 DBG ES Duplex for ESE 606, ESE 1006, ESE 1306 DBG ES Duplex for ESE 606, ESE 1006 DBG ES Duplex for ESE 1306 DBG ES Duplex for all types except ESE 304 HG type with E-Start ESE 606, 1006, 1306, 808, 1308 type with E-Start ESE 606, 1006, 1306, 808, 1308 except for type series ESE 304 HG, ESE 604 162 312 162 313 for E-MCS 3.0 for E-MCS 3.0 NEW ESE 1002 DHG ES Diesel DUPLEX Not for EU countries NEW NEW ESE 1006 DBG Duplex ESE 1006 DBG ES Duplex ESE 1306 DBG ES Duplex ESE 604 DHG ES Diesel Duplex ESE 1002 DHG ES Diesel Duplex 113 004 113 005 113 006 113 009 113 010 synchronous synchronous synchronous synchronous synchronous 12,1/9,7 6,6/5,9 12,1/9,7 6,6/5,9 14,3/11,4 7,7/6,9 6,5/5,3 4,4/4,0 11,0/8,8 6,0/5,4 11,0/8,8 6,0/5,4 11,0/8,8 6,0/5,4 13,0/10,4 7,0/6,3 6,0/4,8 4,0/3,6 10,0/8,0 5,5/5,0 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 15,9 A 3~ 25,0 A 1~ 15,9 A 3~ 25,0 A 1~ 18,8 A 3~ 30,4 A 1~ 8,7 A 3~ 18,0 A 1~ 14,5 A 3~ 21,7 A 1~ 0,8 0,9 0,8 0,9 0,8 0,9 0,8 0,9 0,8 0,9 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 electronic electronic electronic electronic electronic B & S V-Twin B & S V-Twin B & S V-Twin HATZ 1B 40 HATZ 1 D81 C 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 1-cyl. 4-stroke 1-cyl. 4-stroke 570 cm3 570 cm3 627 cm3 462 cm3 667 cm3 13,4 kW/18,0 HP 13,4 kW/18,0 HP 16,7 kW/22,0 HP 6,2 kW/8,4 HP 10,0 kW/13,6 HP Unleaded petrol/20 Unleaded petrol/20 Unleaded petrol/20 Diesel/6 Diesel/15 2,9 l/6,5 h 2,9 l/6,5 h 3,4 l/6,0 h 2,0 l/3 h 2,1 l/7 h Recoil E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery 97 dB(A) 97 dB(A) 96 dB(A) 72 dB(A) 72 dB(A) 71 dB(A) 115 120 144 133 870 x 562 x 640 870 x 562 x 640 870 x 562 x 640 820 x 495 x 570 1105 x 684 x 862 3 x 230 V/16 A 3 x 230 V/16 A 3 x 230 V/16 A 2 x 230 V/16 A 3 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/32 A 1 x CEE 400 V/16 A 97 dB(A) 72 dB(A) 290 for ESE 304 HG), crane loading device for ESE 1002 DHG ES Diesel 400 V 230 V 400 V 230 V 400 V 230 V 400 V 230 V 400 V 230 V 8800 W 5400 W 8800 W 5400 W 10400 W 6300 W 4800 W 3600 W 8000 W 6300 W 8700 W 5300 W 8700 W 5300 W 10300 W 6200 W 4700 W 3500 W 7900 W 6200 W 5800 W 3600 W 5800 W 3600 W 6900 W 4200 W 3200 W 2400 W 5300 W 4200 W 4,5 mm 4100 W 4,5 mm 2500 W 4100 W 6,5 mm 2500 W 4800 W 3,25 mm 2900 W 2200 W 4,5 mm 1700 W DUPLEX-LINE ESE 1306 DBG ES DUPLEX G E N E R AT O R S Includes run hour meter 3700 W 2900 W 23 Duplex Line Silent generators 8 - 13 kVA DUPLEX-LINE G E N E R AT O R S ESE 1008 DHG ES Diesel Duplex Silent Includes run hour meter ESE 808 DBG ES Duplex Silent Available accessories Refuelling system Exhaust pipe Order No. 163 110 163 120 for ESE 808, ESE 1308 DBG ES Duplex Silent for ESE 808, ESE 1308 DBG ES Duplex Silent Options - not retrofit Duplex G5/Idle-down Isometer Cable Remote control (50 m) Remote remole control Multifunktions-Control-System E-MCS 3.0 Detailed description you find on page 7 Warning signal kit Fuel gauge incl. Fuel level sensor Order No. 163 020 010 043 162 006 162 007 162 311 for for for for for 162 312 162 313 for E-MCS 3.0 for E-MCS 3.0 • ESE 808, ESE 1308 DBG ES Duplex Silent all types ESE 808, ESE 1308 DBG ES Duplex Silent ESE 808, ESE 1308 DBG ES Duplex Silent all types NEW 24 • Elaborate silencing system for very • • • NEW good LWA data. Improved cooling air and exhaust concept for safer operation. Optimal operating comfort with new control panel. Larger tank for longer run time. Very good access for maintenance. NEW Type ESE 808 DBG ES Duplex Silent ESE 1308 DBG ES Duplex Silent ESE 1008 DHG ES Diesel Duplex Silent Order No. 113 007 113 008 113 011 Alternator/Duplex G4 synchronous Max. output [LTP] kVA/kW 8,8/7,0 5,4/5,0 14,3/11,4 7,7/6,9 11,0/8,8 7,7/6,9 Constant rating [COP] kVA/kW 8,0/6,4 5,0/4,5 13,0/10,4 7,0/6,3 10,0/8,0 7,0/6,3 Nominal voltage 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 12,3 A 3~ 21,7 A 1~ 18,8 A 3~ 30,4 A 1~ 14,4 A 3~ 30,4 A 1~ Power factor cos (phi) 0,8 0,9 0,8 0,9 0,8 0,9 synchronous synchronous Frequency/Type of protection 50 Hz/IP 54 50 Hz/IP 54 50 Hz/IP 54 Voltage regulation electronic electronic electronic Engine type B & S V-Twin B & S V-Twin HATZ 1 D81 C Version 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 1-cyl. 4-stroke Engine capacity 480 cm3 627 cm3 667 cm3 Max. output [LTP] kVA/kW 11,9 kW/16,0 HP 16,7 kW/22,0 HP 10,0 kW/13,6 HP Fuel/Tank capacity (litres) Unleaded petrol/20 Unleaded petrol/20 Diesel/15 Consumption/Running-time1 2,4 l/8 h 3,4 l/6 h 2,1 l/7 h Start-up system E-start incl. battery E-start incl. battery E-start incl. battery Sound power level LWA2 92 dB(A) 93 dB(A) 96 dB(A) Sound pressure level LPA3 67 dB(A) 68 dB(A) 71 dB(A) Weight kg 137 148 320 Dimensions L x W x H in mm 820 x 440 x 580 820 x 440 x 580 1110 x 684 x 862 Outfit 3 x 230 V/16 A 3 x 230 V/16 A 3 x 230 V/16 A Shockproof sockets 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/32 A Crane loading device Cut-off when lack of oil, overload protection, handles, start-stop system Application areas* 400 V 230 V 400 V 230 V 400 V 230 V Electronic loads up to 6400 W 4500 W 10400 W 6300 W 8000 W 6300 W Electric tools up to 6300 W 4400 W 10300 W 6200 W 7900 W 6200 W Construction equipment up to 4200 W 3000 W 6900 W 4200 W 5300 W 4200 W Inverter welding machines up to 4,0 mm Compressors or pumps 1 2 * 3000 W 6,5 mm 2100 W 4800 W 4,5 mm 2900 W 3700 W Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. 2900W G E N E R AT O R S SILENT POWER-LINE Silent Power Line generators 5 - 12 kVA 25 The new Silent Power Line provides maximum performance and reliability. Designed for professional application where a reduced noise level is important. G E N E R AT O R S SILENT POWER-LINE Silent Power Line generators ESE 608 DBS ES Silent NEW 26 Noise-controlled generators in robust and sturdy design. High quality construction and generous outfit are serial in all Silent Power line generators. • High-quality 2-cylinder OHV engines. • Robust diesel engines. • Compound regulator at 400 V. • Low-oil cut-off protects the engine from damage due to lack of oil. • Generous tank volume for extended run time. • All generators with electric starter, including battery. • Very good access for maintenance. • Optimal operating comfort. • Side panels for perfect dust and weather protection. Type ESE 608 DBS ES Silent Order No. 131 006 Alternator synchronous Max. output [LTP] kVA/kW 6,6/5,3 Constant rating [COP] kVA/kW 6,0/4,8 4,0/3,6 Nominal voltage 400 V 3 ~ 230 V 1~ Nominal current 8,0 A ~ 14,0 A 1~ Power factor cos (phi) 0,8 0,9 Frequency/Type of protection 50 Hz/IP 23 Engine type B & S V-Twin Version 2-cyl. 4-stroke OHV Engine capacity 480 cm3 Max. output 7,5 kW/10,2 HP 4,5/4,0 Fuel/Tank capacity (litres) Unleaded petrol/20 Consumption/Running-time1 2,4 l/8 h Start-up system E-start incl. battery Sound power level LWA2 92 dB(A) Sound pressure level LPA3 67 dB(A) Weight kg 160 Dimensions L x W x H in mm 950 x 457 x 579 Outfit Shockproof sockets 2 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Operating hour meter start-stop system Cut-off when lack of oil, overload Options not retrofit Cable Remote control (40 m cable) Cable Remote control (50 m cable) Order No. 164 000 for type series ESE 1308 HS ES Silent, ESE 608 YS ES Diesel Silent 162 006 for type series ESE 608, ESE 1008 DBS ES Silent Application areas* 400 V 230 V Electric tools up to 4700 W 3500 W Construction equipment up to 3200 W 2400 W Inverter welding machines up to 2,5 mm Compressors or pumps 2200 W 1600 W NEW NEW ESE 1308 HS ES Silent ESE 1308 DHS ES Silent ESE 608 YS ES Diesel Silent 131 005 131 007 131 008 131 009 131 010 synchronous synchronous synchronous synchronous synchronous ESE 608 DYS ES Diesel Silent 11,0/8,8 6,6/5,9 11,9/10,7 13,8/11 9,1/8,2 5,9/5,3 6,9/5,5 4,6/4,1 10,0/8,0 6,0/5,4 10,0/9,0 11,8/9,4 6,9/6,2 4,9/4,4 5,7/4,6 3,3/3,0 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 14,4 A ~ 26,0 A 1~ 43,5 A 1~ 17 A 3~ 30 A 1~ 21,3 A 1~ 8,2 A 3~ 14,3 A 1~ 0,8 0,9 0,9 0,8 0,9 0,9 0,8 0,9 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 B & S V-Twin HONDA GX 620 HONDA GX 620 YANMAR L 100 YANMAR L 100 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 1-cyl. 4-stroke 1-cyl. 4-stroke 570 cm3 614 cm3 614 cm3 406 cm3 406 cm3 13,4 kW/18,0 HP 13,5 kW/18,4 HP 13,5 kW/18,4 HP 6,9 kW/9,4 HP 6,9 kW/9,4 HP Unleaded petrol/20 Unleaded petrol/24 Unleaded petrol/24 Diesel/19 Diesel/19 2,9 l/7 h 3,4 l/7 h 3,4 l/7 h 1,4 l/13,5 h 1,4 l/13,5 h E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery 92 dB(A) 96 dB(A) 96 dB(A) 84 dB(A) 84 dB(A) 67 dB(A) 71 dB(A) 71 dB(A) 59 dB(A) 59 dB(A) 165 166 176 205 205 950 x 457 x 579 930 x 555 x 800 930 x 555 x 800 1050 x 620 x 830 1050 x 620 x 830 2 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Operating hour meter start-stop system 1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A 1 x 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 400 V/16 A 1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A Operating hour meter 1 x 230 V /16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Operating hour meter d protection, crane loading device 400 V 230 V 230 V 400 V 230 V 230 V 400 V 230 V 7900 W 5300 W 8900 W 9300 W 6100 W 4300 W 4500 W 2900 W 5300 W 3600 W 6000 W 6200 W 4100 W 2900 W 3000 W 2000 W 3700 W 1 2 * 5,0 mm 2500 W 4500 W 4700 W 3,25 mm 3100 W 2200 W Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. SILENT POWER-LINE NEW ESE 1008 DBS ES Silent 4,5 mm G E N E R AT O R S ESE 608 DYS ES Diesel Silent ESE 1308 DHS ES Silent 2500 W 1500 W 27 nk with large ta All machines g n ri o n monit and insulatio DIESEL-LINE G E N E R AT O R S Diesel Line generators 3 - 11 kVA 28 Type Order No. Alternator Max. output [LTP] kVA/kW Constant rating [COP] kVA/kW ESE 404 YS-GT ISO Diesel Nominal voltage Nominal current/cos (phi) Power factor cos (phi) Frequency/Type of protection Engine type Version Engine capacity Max. output Fuel/Tank capacity (litres) Consumption/Running-time1 Diesel Line generators have modern quality diesel engines with direct injection. The machines are of high quality, reliability and long life. The engines meet the strictest emission standards and comply with the exhaust norms, e.g., CARB. These generators are preferably used in damp environments such as ducts and shafts, and in areas in which suitable grounding for the generator cannot be produced. Start-up system Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm Outfit Shockproof sockets Application areas* Electric tools up to Construction equipment up to Inverter welding machines up to Compressors or pumps up to Mature engineering for hard professional service. All models with the following serial features: Side walls for perfect protection against dust and weather, large tank and ISOMETER. The isometer provides highest safety and stops the voltage supply instantly in case of an electric fault. G E N E R AT O R S ng Including operati hour meter and ls set of site whee DIESEL-LINE ESE 1004 DRS-GT ISO Diesel ESE 1204 DHS ES ISO Diesel Available accessories Set of wheels Set of wheels Carrying handles Adapter CEE 230 V/16 A of Schuko 230 V/16 A One axle trailer FG 75 ST One axle trailer FG 75 HV Order No. 161 000 161 001 161 002 for ESE 404 YS-GT ISO Diesel except for ESE 404 YS-GT, ESE 1204 DHS ES ISO Diesel for ESE 404 YS-GT ISO Diesel 162 004 341 100 341 101 for ESE 1204 DHS ES ISO Diesel for ESE 1204 DHS ES ISO Diesel Options - not retrofit Cable remote control (40 m) Order No. 164 000 except for ESE 404 YS-GT ISO Diesel ESE 704 DYS-GT ES ISO Diesel ESE 404 YS-GT ISO Diesel ESE 604 YS-GT ES ISO Diesel ESE 704 DYS-GT ES ISO Diesel ESE 1004 DRS-GT ES ISO Diesel ESE 1204 DHS ES ISO Diesel 122 001 131 002 122 003 122 004 122 005 synchronous synchronous synchronous 3,8/3,4 5,9/5,3 6,9/5,5 4,6/4,1 10,2/8,2 6,7/6,0 15,8/12,6 10,4/9,4 3,2/2,9 4,8/4,3 5,7/4,5 3,3/3,0 8,8/7,0 5,1/4,6 11,0/8,8 6,5/5,8 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 13,9 A 1~ 20,9 A 1~ 8,2 A 3~ 14,3 A 1~ 12,7 A 3~ 22,1 A 1~ 15,9 A 3~ 28,3 A 1~ 0,9 50 Hz/IP 23 0,9 50 Hz/IP 23 0,8 0,9 50 Hz/IP 23 0,8 0,9 50 Hz/IP 23 0,8 0,9 50 Hz/IP 23 YANMAR L 70 YANMAR L 100 YANMAR L 100 RUGGERINI MD 150 HATZ 2G 40 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke 2-cyl. 4-stroke OHV 2-cyl. 4-stroke 296 cm3 406 cm3 406 cm3 654 cm3 997 cm3 synchronous synchronous 4,8 kW/6,5 HP 6,9 kW/9,4 HP 6,9 kW/9,4 HP 10,0 kW/13,6 HP 15,4 kW/20,9 HP Diesel/18 Diesel/24 Diesel/24 Diesel/24 Diesel/17 1,0 l/18 h 1,4 l/17 h 1,4 l/17 h 2,1 l/11,5 h 2,3 l/7,5 h Recoil E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery 96 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) 71 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 98 149 153 193 275 800 x 520 x 660 930 x 555 x 800 930 x 555 x 800 930 x 555 x 800 1270 x 830 x 920 1 x 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 400 V/16 A Crane loading device 1 x 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 400 V/16 A Crane loading device 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A Crane loading device 1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A Crane loading device Voltmeter, isometer, overload protection 230 V 230 V 400 V 230 V 400 V 230 V 400 V 230 V 2800 W 4200 W 4400 W 2900 W 6900 W 4500 W 8700 W 5700 W 1900 W 2800 W 3000 W 2000 W 4600 W 3000 W 5800 W 3800 W 3,25 mm 1500 W 2100 W 1 2 * 2200 W 4,0 mm 1500 W 3500 W 4,5 mm 2300 W 4400 W Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. 2900 W 29 G E N E R AT O R S ACCORDING TO DIN 14685 Generators according to DIN 14685 3 - 15 kVA 30 M G DUPLEX ENDRESS generators according to DIN 14685 - reliable and robust helpers for harsh environments - for fire brigades, civil protection and rescue missions. E Convincing points for the DIN generators with DUPLEX technology • Brushless synchronous generator with electronic control. • 4-time start-up current, 200% load unbalance. • Simultaneous operation of electronic and inductive consumers possible. • 20000 generator hours. Maintenance-free. • Automatic choke as serial feature in all versions with remote starter. • Engine protection by low oil cut-off. • Protection against overheating by heat deflection panels. Option: DUPLEX G5 technology Slows down the engine to the lowest possible speed in idle running. • The new DIN generators in 8-size frame, 8 - 13 kVA, set standards of quality, technology and outfit. Multifunction Control System E-MSC 3.0 as standard. For a detailed description, see p. 7. • Optimal operator comfort with new control panel. • • • • • The perfect multifunction control system from ENDRESS. A system for optimal safety and user friendliness in everyday use. CanBus capability included as standard. G E N E R AT O R S • • All displays, control and operation functions at a glance. Keyless start by START/STOP/EMERGENCY STOP button. New place for the tank for less heating, less sensitive to temperature. Visual fuel level. 50% larger tank capacity. Improved tank opening, higher filler neck. New B & S V-Twin engines 0.5 dB(A) less noise than earlier model´lower oil temperature - higher life expectancy. Noise reduced by 3 dB(A). Option: CanBus link-up The link between the unit and the customer’s operator panel is provided by a control interface unit (CIU). Before data can be exchanged, some customization must take place at the ENDRESS factory. Option: exhaust hose Electronics Option: Filling system Control box ESE 804 DBG ES DIN Higher filler neck ACCORDING TO DIN 14685 NEW Visual fuel level in tank 31 ACCORDING TO DIN 14685 Generators according to DIN 14685 • Multifunction Control System E-MCS 3.0 • Keyless start by START/STOP/EMERGENCY STOP button. • New B & S V-Twin engines in ESE 854 DBG DIN • CanBus capability G E N E R AT O R S (except ESE 304 HG, ESE 604 DYG DIN). ESE 604 DYG DIN ESE 304 HG ESE 604 DBG DIN aligned to DIN 14685 32 5er DIN frame Type ESE 304 HG ESE 604 DYG DIN ESE 604 DBG DIN Order No. 151 000 151 001 1151 002 ESE 854 DBG DIN 151 004 Alternator/Duplex G4 synchronous synchronous synchronous synchronous Max. output [LTP] kVA/kW 3,3/3,0 6,6/5,3 4,4/4,0 6,6/5,3 4,4/4,0 8,8/7,0 5,5/5,0 Constant rating [COP] kVA/kW 3,0/2,4 6,0/4,8 4,0/3,6 6,0/4,8 4,0/3,6 8,0/6,4 5,0/4,5 Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 13 A 1~ 8,7 A 3~ 18,0 A 1~ 8,7 A 3~ 18,0 A 1~ 12,3 A 3~ 21,7 A 1~ Power factor cos (phi) 0,9 0,8 0,9 0,8 0,9 0,8 0,9 Frequency/Type of protection 50 Hz/IP 54 50 Hz/IP 54 50 Hz/IP 54 50 Hz/IP 54 Voltage regulation electronic electronic electronic electronic Engine type HONDA GX 200 HONDA GX 390 B & S VANGUARD B & S VANGUARD Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV Engine capacity 196 cm3 357 cm3 480 cm3 480 cm3 Max. output 4,3 kW/5,8 HP 7,5 kW/10,2 HP 7,5 kW/10,2 HP 11,9 kW/16,0 HP Fuel/Tank capacity (litres) Unleaded petrol/3,6 Unleaded petrol/6,7 Unleaded petrol/8,5 Unleaded petrol/8,5 Consumption/Running-time1 1,2 l/3 h 2,1 l/3 h 2,4 l/3,5 h 2,4 l/3,5 h Start-up system Recoil Recoil Recoil Recoil Sound power level LWA2 96 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) Sound pressure level LPA2 71 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) Weight kg 53 95 117 114 Dimensions L x W x H in mm 555 x 405 x 445 700 x 440 x 580 700 x 440 x 580 700 x 440 x 580 Outfit 2 x 230 V/16 A 3 x 230 V/16 A, DIN 49442 Shockproof sockets IP 68 according to VDE-norm 1 x CEE 400/16 A, DIN 49462 Overload protective switch 3 x 2-pole, 1 x 4-pole circuit breaker, protective conductor test equipment, cut-off when lack of oil, Cut-off when lack of oil On-board tool: 1 x spark plug spanner, 2 x spark plug, 1 x testing spike and 1 testing cable-1 m long Multifunction control display E-MCS 3.0 standard Types with electric start without battery ESE 604 DBG ES DIN ESE 854 DBG ES DIN Order No. 151 012 151 014 Types with electric start and remote control incl. automatic choke without battery ESE 604 DBG ES FS DIN ESE 854 DBG ES FS DIN Order No. 151 022 151 024 1 2 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. ACCORDING TO DIN 14685 Modern and more powerful consumers need more output from mobile generators. The development of such units is governed by customer and market demands. Therefore, we constantly add new versions to our product lines. The new DUPLEX generators in size 8 DIN frame set new standards in precision and reliability. Serial features: G E N E R AT O R S • Multifunction Control System E-MCS 3.0. • CanBus capability. • Carrying handles in flexible supports. • Visual fuel level. • Tank holds 12 liters ESE 1304 DBG ES DIN 8er DIN frame ESE 804 DBG DIN ESE 1104 DBG ES DIN 151 003 151 015 ESE 1304 DBG ES DIN 151 016 synchronous synchronous synchronous Optional: DUPLEX G5 technology Slows down the engine to the lowest possible speed in idle running. 8,8/7,0 5,5/5,0 12,1/9,7 7,7/6,9 14,3/11,4 7,7/6,9 8,0/6,4 5,0/4,5 11,0/8,8 7,0/6,3 13,0/10,4 7,0/6,3 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 12,3 A 3~ 21,7 A 1~ 15,9 A 3~ 30,4 A 1~ 18,8 A 3~ 30,4 A 1~ 0,8 0,9 0,8 0,9 0,8 0,9 50 Hz/IP 54 DIN 40050 50 Hz/IP 54 DIN 40050 50 Hz/IP 54 DIN 40050 electronic electronic electronic B & S VANGUARD B & S VANGUARD B & S VANGUARD 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 480 cm3 627 cm3 627 cm3 11,9 kW/16,0 HP 14,8 kW/20,0 HP 16,7 kW/22,0 HP Unleaded petrol/20 Unleaded petrol/12,0 Unleaded petrol/12,0 2,4 l/5 h 3,4 l/3,5 h 3,4 l/3,5 h Recoil E-Start E-Start 97 dB(A) 98 dB(A) 98 dB(A) 72 dB(A) 73 dB(A) 73 dB(A) 139 155 154 820 x 440 x 580 820 x 440 x 580 820 x 440 x 580 3 x shockproof sockets 230 V/16 A according to DIN 49442 2 x three-phase-CEE socket 400/16 A according to DIN 49462 handle elastically supported, optical fuel gauge, painting powder-coated RAL 1012 to testing device for earthed conductor ESE 804 DBG ES DIN 151 013 ESE 804 DBG ES FS DIN ESE 1104 DBG ES FS DIN ESE 1304 DBG ES FS DIN 151 023 151 025 151 026 Available accessories Battery 12 V - 18 Ah maintenance-free Refuelling system Exhaust pipe cable drum ELT 50/3 Options not retrofit 3-Way-Valve for ext. refuelling 33 Order No. 163 040 Range with E-start 163 110 suitable for 3-way-fuel cock 163 120 except for ESE 304 HG E 132 513 Order No. 163 050 Type series with B & S VANGUARD engines Duplex-G5/ Idle down Isometer Automatic choke Automatic choke Part set - remote-start-Nato-socket Part set - battery charge with charging socket DIN 14690 Part set - battery charge with solenoide socket MagCode 163 010 Range with E-start 163 018 Warning signal kit II Fuel gauge incl. fuel level sensor Special sockets 162 312 162 313 on request except for range 604 DBG, 854 DBG and ESE for E-MCS 3.0 for E-MCS 3.0 163 163 163 163 163 020 070 030 031 000 Range with E-start except for ESE 304 HG Range 6-8,5 kVA with E-start Range 11-13 kVA with E-start Range with E-start ACCORDING TO DIN 14685 SILENT G E N E R AT O R S 34 Generators according to DIN 14685 Silent • Multifunction Control System E-MCS 3.0. • Complete aluminum enclosure for • • • • • • • • lower weight. Elaborate silencing system for very good LWA data. Improved cooling air and exhaust concept for safer operation. Optimal operating comfort with new control panel. Very good access for maintenance. 12h/18 Ah battery, maintenance-free. 3-way fuel cock for external filling. Visual fuel level. CanBus capability. 8er DIN Rahmen Type ESE 804 DBG ES DIN ESE 1304 DBG ES DIN Silent Silent Order No. 151 413 151 416 Alternator/Duplex G4 synchronous synchronous Max. output [LTP] kVA/kW 8,8/7,0 5,5/5,0 14,3/11,4 7,7/6,9 Constant rating [COP] kVA/kW 8,0/6,4 5,0/4,5 13,0/10,4 7,0/6,3 Nominal voltage 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 12,3 A 3~ 21,7 A 1~ 18,8 A 3~ 30,4 A 1~ Power factor cos (phi) 0,8 0,9 0,8 0,9 Frequency/Type of protection 50 Hz/IP 54 50 Hz/IP 54 Voltage regulation electronic electronic Engine type B & S VANGUARD B & S VANGUARD Version 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV Engine capacity 480 cm3 627 cm3 Max. output 11,9 kW/16,0 HP 16,7 kW/22,0 HP Fuel/Tank capacity (litres) Unleaded petrol/12 Unleaded petrol/12 Consumption/Running-time1 2,4 l/5 h 3,4 l/3,5 h Start-up system E-start incl. battery E-start incl. battery Sound power level LWA2 92 dB(A) 94 dB(A) Sound pressure level LPA3 67 dB(A) 69 dB(A) Weight kg 136 148 Dimensions L x W x H in mm 820 x 440 x 580 820 x 440 x 580 Outfit 3 x shockproof sockets 230 V/16 A, according to DIN 49442, 1 x CEE socket 400 V/16 A, according to DIN 49462, Multifunctional Control Display E-MCS 3.0 standard, 3 x 2-pole und 1 x 4-pole automatic circuit-breakers, testing device for earthed conductor, cut-off when lack of oil, 3-way-fuel valve for external fuelling, carrying handles elastically supported, optical fuel gauge, powdercoated RAL 1012. On-board tool: 1 x spark plug spanner, 2 x spark plug, 1 x testing spike and 1 testing cable1 m long to testing device for earthed conductor Types with electric start and remote start device incl. automatic choke and battery Type ESE 804 DBG ES FS DIN ESE 1304 DBG ES FS DIN Silent Silent Order No. 151 423 151 426 Available accessories Exhaust pipe Refuelling system 1 2 * Order No. 163 120 163 110 all types suitable for 3-wax fuel cock Options not retrofit Duplex G5/Idle-down Isometer Automatic choke Automatic choke Part set - remote-start-Nato-socket Part set - battery charge with charging socket DIN 14690 Part set - battery charge with solenoide socket MagCode Warning signal kit II Fuel gauge incl. fuel level sensor Special sockets Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. Options not retrofit. Order No. 163 020 163 070 163 030 163 031 163 003 all types all types ESE 804 DBG ES DIN Silent ESE 1304 DBG ES DIN Silent all types 163 013 all types 163 018 162 312 162 313 on request all types for E-MCS 3.0 for E-MCS 3.0 E M TRIPLEX G TRIPLEX technology • Engine speed adapts to output • • • requirement. Optimal efficiency of the engine is used. Any type of current can be supplied. Any frequency can be generated. For global use: constant voltage and frequency independent of the engine speed (variable speed constant frequency) 8er DIN frame Type ESE 1504 DBT ES DIN TRIPLEX Silent Order No. 151 800 Alternator permanently excited Max. output [LTP] kVA/kW 16,5/13,2 5,5/4,4 Constant rating [COP] kVA/kW 15,0/12,0 5,0/4,0 Nominal voltage 400 V 3~ 230 V 1~ Nominal current 20,0 A 3~ 21,8 A 1~ Power factor cos (phi) 0,8 0,9 TRIPLEX, the intelligent way of generating electricity. Low weight, compact unit and high efficiency are typical features of TRIPLEX generators. Engine, generator and electronics form an intelligent unit. The variable speed design of the unit and the automatic adjustment of the engine speed to the power requirement open versatile applications around the globe: whether 3-phase, AC or DV; 50 Hz, 60 Hz, 230 V or 115 V. Other frequencies can be generated reliably without complicated cooling or rectifier, e.g., 400 Hz on-board networks - or any other defined value. Frequency/Type of protection 50 Hz/IP 54 Insulation class/Interf. degree F-VDE 05030/N-VDE 0875 Voltage regulation electronic Engine type B & S VANGUARD Version 2-cyl. 4-stroke OHV Engine capacity 627 cm3 Max. output 16,7 kW/22,0 HP Fuel/Tank capacity (litres) Unleaded petrol/12 Consumption/Running-time1 3,4 l/3,5 h Start-up system E-start incl. battery Sound power level LWA2 92 dB(A) Sound pressure level LPA3 67 dB(A) Weight kg 148 Dimensions L x W x H in mm 820 x 440 x 580 Outfit User benefits • Substantial reduction of pollutant and noise emission. • Reduced fuel consumption. • Less wear, longer engine life. smooth electricity under all conditions, distortion factor • Extremely less than 1%. • Ultrafine electronic assemblies can be used. • Each connection is isolated from all other connections. operation of machines which are difficult to start with sensitive • Mixed consumers is possible without hazard. lower operating costs due to extended service intervals • Substantially und less maintenance. like ESE 1304 DBG ES DIN Silent see page 34 Available accessories Refuelling system 1 2 Order No. 163 110 suitable for 3-way fuel cock Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. ACCORDING TO DIN 14685 SILENT VA Genuine 15 k frame in 8-size DIN G E N E R AT O R S Top-notch technology Fire brigades, emergency management and rescue services 35 Export Line generators 3 - 13 kVA EXPORT-LINE G E N E R AT O R S Not for EU countries Not for EC 36 ESE 404 YS Diesel ESE 604 DYS ES Diesel Profi Diesel This line employs high-quality diesel engines. Highperformance synchronous generators with strengthened phase winding are added. A sturdy monobloc tube frame with large side panels protects engine and alternator. Type Available accessories Set of wheels Crane loading device Refuelling system Order No. 161 000 for all types E 101 115 for type ESE 1104 DBS, ESE 1104 DBS ES 163 110 for type ESE 1104 DBS, ESE 1104 DBS ES Options - not retrofit Cable Remote control (40 m) Automatic control panel 3-way fuel cock Idle down Duplex G5 Order No. 164 000 162 311 162 005 162 200 for for for for ESE 604 DYS ES Diesel, ESE 904 DRS ES ESE 604 DYS ES Diesel, ESE 904 DRS ES type ESE 1104 DBS, ESE 1104 DBS ES ESE 1314 DBG ES Duplex ESE 404 YS ESE 604 YS ESE 604 DYS ESE 604 DYS ES ESE 904 DRS ES Diesel Diesel Diesel Diesel Diesel Order No. 121 000 121 004 121 001 121 002 121 003 Alternator synchronous synchronous synchronous synchronous synchronous Max. output [LTP] kVA/kW 3,9/3,5 5,9/5,3 6,9/5,5 4,6/4,1 6,9/5,5 4,6/4,1 10,2/8,21 Constant rating [COP] kVA/kW 3,3/3,0 4,8/4,3 5,7/4,5 3,3/3,0 5,7/4,5 3,3/3,0 8,8/7,0 6,7/6,0 5,1/4,6 Nominal voltage 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 14,3 A 1~ 20,9 A 1~ 8,2 A 3~ 14,3 A 1~ 8,2 A 3~ 14,3 A 1~ 12,7 A 3~ 22,2 A 1~ Power factor cos (phi) 0,9 0,9 0,8 0,9 0,8 0,9 0,8 0,9 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 Engine type YANMAR L 70 YANMAR L 100 YANMAR L 100 YANMAR L 100 RUGGERINI MD 150 Version 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke 2-cyl. 4-stroke Engine capacity 296 cm3 406 cm3 406 cm3 406 cm3 654 cm3 Max. output 4,8 kW/6,5 HP 6,9 kW/9,4 HP 6,9 kW/9,4 HP 6,9 kW/9,4 HP 10,0 kW/13,6 HP Fuel/Tank capacity (litres) Diesel/3,5 Diesel/5,5 Diesel/5,5 Diesel/5,5 Diesel/24 Consumption/Running-time1 1,0 l/3,5 h 1,4 l/4 h 1,4 l/4 h 1,4 l/4 h 2,0 l/12 h Start-up system Recoil Recoil Recoil E-start incl. battery E-start incl. battery Weight kg 54 100 96 112 153 Dimensions L x W x H in mm 760 x 490 x 530 800 x 575 x 570 800 x 575 x 570 830 x 490 x 570 970 x 600 x 690 Outfit Shockproof sockets 2 x 230 V/16 A 1 x 230 V/16 A 1 x CEE230 V/32 A 1 x 230 V/16 A 1 x CEE 400 V/16 A 2 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Voltmeter 1 x 230 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A Voltmeter Application areas* 230 V 230 V 400 V 230 V 400 V 230 V 400 V Electric tools up to 2900 W 4200 W 4400 W 2900 W 4400 W 2900 W 6900 W 4500 W Construction equipment up to 2000 W 2900 W 3000 W 2000 W 3000 W 2000 W 4600 W 3000 W 1400 W 3500 W Overload protection Inverter welding machines up to Compressors or pumps 1 1400 W 3,25 mm 2000 W 2200 W 3,25 mm 1400 W Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. **Not for EU countries - export model ***Not according to directive 2000/14/EG 2 * 2200 W 230 V 4,0 mm 2300 W countries! Not for EU countries Where large and heavy units were needed for 25 kVA supply, today the handy ENDRESS Power Pack ESE 1314 DBG ES DUPLEX is enough. EXPORT-LINE G E N E R AT O R S el Including 3-wayfu e ibl tank and collaps handles ESE 1104 DBS ESE 1104 DBS for harsh professional duty • B & S VANGUARD 2-cylinder OHV engine. • High-performance synchronous generators. • Compound regulator at 400 V. • Large side panels protect engine and generator. • Handles. ESE 4000 DS ESE 5000 DS ESE 5000 DS ES Diesel Diesel Diesel ESE 1314 DBG ES Duplex ESE 1104 DBS ESE 1104 DBS ES ESE 1314 DBS ES Duplex 250 001 250 002 250 003 121 005 121 006 051 307 synchronous synchronous synchronous synchronous synchronous synchronous/Duplex-G4 3,6/3,2 5,4/4,9 5,4/4,9 11,0/8,8 6,6/5,9 11,0/8,8 6,6/5,9 14,3/11,4 7,7/6,9 3,3/3,0 4,8/4,3 4,8/4,3 10,0/8,0 6,0/5,4 10,0/8,0 6,0/5,4 13,0/10,4 7,0/6,3 230 V 1~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1 14,3 A 1~ 20,7 A 1~ 20,7 A 1~ 14,4 A 3~ 26,1 A 1~ 14,4 A 3~ 26,1 A 1~ 14,4 A 3~ 26,1 A 1~ 0,9 0,9 0,9 0,8 0,9 0,8 0,9 0,8 0,9 50 Hz/IP 23 M 50 Hz/IP 23 M 50 Hz/IP 23 M 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 B & S VANGUARD B & S VANGUARD B & S VANGUARD 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 296 cm3 406 cm3 406 cm3 570 cm3 570 cm3 627 cm3 4,0 kW/5,4 HP 6,5 kW/8,8 HP 6,5 kW/8,8 HP 12,0 kW/16,3 HP 12,0 kW/16,3 HP 14,8 kW/20,1 HP Diesel/30 Diesel/30 Diesel/30 Unleaded petrol/8,5 Unleaded petrol/8,5 Unleaded petrol/8,5 1,0 l/30 h 1,5 l/20 h 1,5 l/20 h 2,8 l/3 h 2,8 l/3 h 3,4 l/2,5 h Recoil Recoil E-start incl. battery Recoil E-start incl. battery E-start incl. battery 73 89 107 103 107 144 805 x 558 x 580 805 x 558 x 580 805 x 558 x 580 945 x 570 x 640 945 x 570 x 640 820 x 440 x 580 2 x 230 V/16 A 1 x 230 V/16 A 1 x CEE 230 V/32 A 1 x 230 V/16 A 1 x CEE 230 V/32 A 2 x 230 V/16 A 1 x CEE400 V/16 A Cut-off when lack of oil Handles 2 x 230 V/16 A 1 x CEE 400 V/16 A Cut-off when lack of oil Handles 3 x 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/32 A Cut-off when lack of oil 230 V 230 V 230 V 400 V 230 V 400 V 230 V 400 V 230 V 2900 W 4200 W 4200 W 7900 W 5300 W 7900 W 5300 W 10400 W 6200 W 2000 W 2800 W 2800 W 5300 W 3600 W 5300 W 3600 W 6900 W 4200 W 4,5 mm 1400 W 2100 W 2100 W 4000 W 4,5 mm 2700 W 4000 W 6,5 mm 2700 W 5200 W 2900 W 37 EMERGENCY POWER SUPPLY Mobile emergency supply for 230rsV consume G E N E R AT O R S Professional emergency power supply for the in-house network 38 Please note! The power requirement must not be higher than the continuous output of the set. Otherwise damage can occur. Recommended: Always remain 10% below the continuous output. This extends the life of the machine. Important! The in-house installation and feeding connection must be made by a specialized electrical installation firm which warrants the proper and safe installation. That firm will also advise you as to the choice of the correct emergency supply set. Inform your electricity supplier of your intention and study the supplier’s general terms. Conditions are different from country to country. 5 steps for quick emergency supply 1 Generator set outdoors - set it up at a place protected from rain and moisture. 2 Make the connection between the generator set and the consumers. 3 Start the set. 4 Set the switch of the ENDRESS manual transfer switch to “emergency supply”. 5 Electricity is supplied. Simple and quick power supply in the whole house with the ENDRESS emergency set, a reliable supply source for all important 230 V consumers. The ENDRESS emergency set ensures that emergency power is available throughout the house in very short time. No extension cables or multiple socket outlets. The feeding distributor E-NEV/1 ensures that 230 V supplied by the generator is distributed to emergency consumers in the house via distribution boxes. EMERGENCY POWER SUPPLY G E N E R AT O R S 39 An important advantage of this system is that there is no need to check if the consumers in the house need grounded supply because the feeding distributor ensures that the generator set is automatically integrated in the in-house network. For use in DIY rooms and similar environments, simply separate the set from the in-house network for unrestricted mobile application. 230 V load Standby-set with the Professional GT Line 2-11 kVA Type ESE 606 HS-GT ESE 1206 HS-GT ES Order No. 112 002 112 021 Type manual transfer switch E-NEV/3-32 E-NEV/3-32 Order No. 162 301 162 301 Max. connection power 5400 W 10000 W Recommended collecting power 4900 W 9000 W Possible application areas Heating system Lighting Multimedia Communication Appliances Cooling Heating system Lighting Multimedia Communication Appliances Cooling Pumps Warm water preparation Detailed description and technical data you find on page 17-18. ESE 1206 HS-GT ES Mobile emergency supply for 400rsV consume G E N E R AT O R S EMERGENCY POWER SUPPLY Professional emergency power supply for the in-house network 40 5 steps for quick emergency supply 1 2 3 4 5 PETROL Standby set with the DUPLEX-LINE 6-13 kVA Type 400 V load The perfect emergency power supply in the whole house - without extension cables or multiple outlet sockets. The ENDRESS emergency set is a reliable emergency power source for all consumers. Generator set outdoors - set it up at a place protected from rain and moisture. Make the connection between the generator set and the consumers. Start the set. Set the switch of the ENDRESS manual transfer switch to "emergency supply". Electricity is supplied. ESE 604 DHG ESE 606 DBG ESE 606 DBG ES ESE 1006 DBG ESE 1006 DBG ES Duplex Duplex Duplex Duplex Duplex Duplex Order No. 113 000 113 002 113 003 113 004 113 005 113 006 Type manual transfer switch E-NEV/3-16 E-NEV/3-16 E-NEV/3-16 E-NEV/3-16 E-NEV/3-16 E-NEV/3-32 Order No. 162 303 162 303 162 303 162 303 162 303 162 304 Max. connection power 4800 W 4800 W 4800 W 8800 W 8800 W 10400 W Recommended collecting power 4300 W 4300 W 4300 W 8100 W 8100 W 9400 W Possible application areas Detailed description and technical data you find on page 22-23. Complete house supply ESE 1306 DBG ES Synchronous 3-phase generators are not the best choice for 3-phase emergency supply. Because they cannot stand unbalanced load*. For this reason, ENDRESS uses the proven G4 DUPLEX technology for safe and reliable 3-phase emergency supply. * Unbalanced load is the state in which the phases of a 3-phase system carry unequal load. If needed, simply separate the set from the in-house network for unrestricted mobile application. The advantage of the Duplex technology is that the brushless synchronous generator IP 54 has full electronic control and can stand 200% load unbalance. Besides, this technology provides 100% constant voltage, distortion factor of less than 5% and 4 times the start-up current. This makes these sets not only suitable for the private home but also for small businesses to maintain computer supply in the case of a power outage. Thus, these generators are best for the difficult requirements which consumers make on an emergency generating set. EMERGENCY POWER SUPPLY The decisive advantage G E N E R AT O R S With this system, power is fed from the set into the in-house network via feeding distributor E-NV/3. This configuration is the same as a standard 3-phase feeding system known from the supplying network. All consumers, including 3-phase, in the house can be supplied. Emergency power sets in combination with the proven DUPLEX technology make a perfect match for emergency power supply in the whole house. 41 ESE 1308 ES Duplex Silent ESE 1008 DBG ES Diesel Duplex Silent SOUNDPROOF D IE SEL Standby set with the DUPLEX-LINE 6-13 kVA 400 V load Type ESE 808 DBG ES ESE 1308 DBG ES ESE 1002 DHG ES ESE 1008 DHG ES Duplex Silent Duplex Silent Diesel Duplex Diesel Duplex Silent Diesel Duplex Order No. 113 007 113 008 113 010 113 011 113 009 Type manual transfer switch E-NEV/3-16 E-NEV/3-32 E-NEV/3-16 E-NEV/3-16 E-NEV/3-16 Order No. 162 303 162 304 162 303 162 303 162 303 Max. connection power 6400 W 10400 W 8000 W 8000 W 4800 W Recommended collecting power 5800 W 9400 W 7200 W 7200 W 4300 W Possible application areas Detailed description and technical data you find on page 22-23. Complete house supply ESE 606 DBG ES G E N E R AT O R S EMERGENCY POWER SUPPLY Automatic power supply 42 ENDRESS fully automatic emergency generator systems, together with the automatic control unit, automatically restore the power supply if the mains supply fails. The mains voltage is monitored automatically and if a drop is detected in one PETROL TYPE SERIES 5-12 kVA 230 V load Type or several phases, the engine starts automatically - manual starting is also possible. When the power supply is restored, the set cuts out automatically. ESE 606 HS-GT/A ESE 1206 HS-GT/A DIESEL ESE 1308 HS/A ESE 604 YS-GT/A ESE 608 YS/A Silent Diesel Diesel Silent Order No. 112 105 112 106 131 105 122 105 131 106 Max. connection power 5500 W 9100 W 9100 W 4300 W 4400 W Recommended demand power 5000 W 8200 W 8200 W 3900 W 4000 W Possible application areas Heating system Lighting Multimedia Communication Appliances Cooling Heating system Lighting Multimedia Communication Appliances Cooling Pumps Warm waterpreparation Heating system Lighting Multimedia Communication Appliances Cooling Pumps Warm waterpreparation Heating system Lighting Multimedia Communication Appliances Heating system Lighting Multimedia Communication Appliances page 27 page 29 page 29 Detailed description and specifications you find on page 17-18. EMERGENCY POWER SUPPLY ENDRESS automatic emergency set 5 - 13 kVA. This series is a complete system with latest generator technology. The high-performance synchronous generators supply single-phase 230 V consumers in the house. For 3-phase supply, ENDRESS uses DUPLEX generators (a brushless synchronous generator IP 54 with electronic control), which are excellent for individual household consumers, also for medium-size businesses, e.g., to maintain the power supply to computers in case of a mains power outage. G E N E R AT O R S 5-12 kVA 1-phase feeding series These generators are factory wired with the automatic emergency machine and therefore need no socket outlet. Automatic emergency function cannot be service fitted. 8-13 kVA 3-phase feeding series The connection of the automatic emergency function in these models is made by a separate connection to the set, which can also be disconnected and used for mobile applications. 43 Only strong components will make powerful generators. For reasons of technical competence, ENDRESS relies on high-end industrial engines from DEUTZ and VOLVO Penta as well as quality generators from STAMFORD and Mecc Alte. (Detailed system descriptions from p. 54). PETROL TYPE SERIES 6-13 kVA 400 V load Type SOUNDPROOF ESE 606 DBG/A ESE 1006 DBG/A ESE 1306 DBG/A ESE 808 DBG/A Duplex Duplex Duplex Duplex Silent Duplex Silent Order No. 113 200 113 201 113 202 113 203 113 204 Max. connection power 4800 W 8800 W 10400 W 6400 W 10400 W Recommended collecting power 4300 W 8100 W 9400 W 5800 W 9400 W Possible application areas Complete house supply DIESEL TYPE SERIES 6-13 kVA Type ESE 1002 DHG/A ESE 1008 DHG/A Diesel Duplex Diesel Duplex Silent Order No. 113 207 113 206 Max. connection power 8000 W 8000 W Recommended collecting power 7200 W 7200 W Possible application areas Complete house supply Detailed description and specifications you find on page 22-24. ESE 1308 DBG/A G E N E R AT O R S WELDING-LINE Welding Line generators 30 - 200 A 44 Welding generator selection chart The table below can be used for guidance and does not purport to be exhaustive. No claims can be based on this table. ESE 704 SHS-AC ESE 804 SDHA-DC ESE 804 SDHA-DC ES ENDRESS welding generators are versatile energy sources which supply three-phase, alternating and welding currents. Due to their excellent welding characteristics, they are simply indispensable for repair work such as in steel and pipeline engineering. On-load factor (OLF) OLF = tb x 100% (tb + tp) tb = load duration tp = pause duration tb + tp = cycle duration (acc. To VDE 0544. tb + tp = 10 min) Example: 60% on-load factor yields a succession of 6 min welding and 4 min pause. ø 1,5 50 ø2 70 ø 2,5 90 ø 3,25 110 ø 3,25 130 ø 3,25 150 ø4 170 ø4 190 ø5 210 ø5 35 % ED 60 % ED 35 % ED Electrode 30 100 % ED welding current (A) 60 % ED ESE 504 SDHA 100 % ED ESE 404 SHS-AC ESE 504 SDHA-DC ESE 504 SDYA-DC ES Diesel • Continuous welding current regulation - at constant motor speed. • Silent, easy ignitable arcs, drop weld proof, K symbol (only at DC-models). • Modern HONDA-OHV engine technology. • Economical, reliable diesel units. • Sturdy asynchronous generators. • AC = AC welding for simple welding. • DC = DC welding for professional welding. ESE 404 SHS-AC ESE 804 SDYA-DC ES Not for EC-countries Type ESE 404 SHS-AC ESE 704 SHS-AC ESE 504 SDHA-DC ESE 804 SDHA-DC ESE 504 SDYA-DC ES Order No. 141 008 141 007 141 000 141 001 141 003 Alternator synchronous synchronous asynchronous asynchronous asynchronous Max. output [LTP] kVA/kW 3,9/3,5 6,9/6,2 5,0/4,0 4,4/4,0 6,4/5,1 4,4/4,0 5,3/4,2 4,4/40 Constant rating [COP] kVA/kW 3,3/3,0 5,9/5,3 4,5/3,6 4,0/3,6 6,0/4,8 4,0/3,6 5,0/4,0 4,0/3,6 Nominal voltage 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ Nominal current 14,3 A 1~ 25,7 A 1~ 6,5 A 3~ 17,4 A 1~ 8,7 A 3~ 17,4 A 1~ 7,2 A 3~ 17,4 A Power factor cos (phi) 0,9 0,9 0,8 0,8 0,8 0,9 Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 44 50 Hz/IP 44 Min./Max. welding output (A) 60 - 180 60 - 200 30 - 170 30 - 200 30 - 180 180 130 170 140 DIESEL Welding current intensity at 60 % (A) 125 0,9 400 V 3~ 230 V 1~ 0,9 400 V 1~ 230 V 1~ 50 Hz/IP 44 Off-load voltage (V) 45 ÷ 60 45 ÷ 60 95 95 95 Min./Max. welding voltage (V) 22,4/27,2 22,4/28 21,2/26,8 21,2/28,0 21,2/27,2 Welding regulation mechanical mechanical mechanical mechanical mechanical Engine type HONDA GX 270 HONDA GX 390 HONDA GX 270 HONDA GX 390 YANMAR L 100 AE Engine version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke 1-cyl. 4-stroke OHV 1-cyl. 4-stroke Engine capacity 270 cm³ 389 cm³ 270 cm³ 389 cm³ 406 cm³ Max. output 6,3 kW/8,6 HP 8,3 kW/11,3 HP 6,3 kW/8,6 HP 8,3 kW/11,3 HP 6,9 kW/9,4 HP Fuel/Tank capacity (litres) Unleaded petrol/6 Unleaded petrol/6,5 Unleaded petrol/6 Unleaded petrol/6,5 Diesel/24 Consumption/Running-time1 1,7 l/,5 h 2,1/3 h 1,65 l/3,5 h 2,1 l/3 h 1,4 l/17 h Start-up system Recoil Recoil Recoil Recoil E-start incl. battery Sound power level LWA2 97 dB(A) 97 dB(A) 97 dB(A) Sound pressure level LPA3 72 dB(A) 72 dB(A) 72 dB(A) Weight kg 62 76 115 115 180 Dimensions L x W x H in mm 802 x 510 x 510 802 x 510 x 510 830 x 490 x 570 830 x 490 x 570 930 x 555 x 800 Outfit 2 x 230 V/16 A 2 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 3 x CEE 230 V/16 A Voltmeter Cut-off when lack of oil Thermic winding shield, overload protection Type ESE 804 SDHA-DC ES Order No. 141 002 with E-start incl. battery Available accessories Adapter CEE 230 V/16 A to shockproof socket 230 V/16 A 162 004 162 004 162 004 162 004 162 004 Set of wheels with handles 161 000 161 000 161 000 161 000 161 001 Welding accessories 162 000 162 000 162 000 162 000 162 000 Application areas Rutile electrode max. Ø mm 4 4 4 5 4 Basic electrode max. Ø mm – – 3,25 4 4 Cellulose electrode max. Ø mm – – 3,25 5 4 1 2 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. G E N E R AT O R S ESE 704 SHS-AC front view WELDING-LINE ESE 404 SHS-AC front view 45 G E N E R AT O R S PTO GENERATORS PTO generators 12 - 55 kVA 46 Types with 3000 rpm Type EZG 11/2 EZG 15/2 EZG 20/2 EZG 25/2 EZG 29/2 Order No. 511 007 511 008 511 009 511 010 511 011 EZG 35/2 511 012 Alternator synchronous synchronous synchronous synchronous synchronous synchronous Constant rating [COP] kVA/kW 21,1/9,7 14,4/11,5 19,8/15,9 24,3/19,4 28,3/22,7 34,2/27,4 Nominal voltage 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ Nominal current 17,5 A 3~ 20,8 A 3~ 28,6 A 3~ 35,1 A 3~ 40,8 A 3~ 49,4 A 3~ Power factor cos (phi) 0,8 0,8 0,8 0,8 0,8 0,8 Frequency/Type of protection 50 Hz/IP 44 50 Hz/IP 44 50 Hz/IP 44 50 Hz/IP 44 50 Hz/IP 44 50 Hz/IP 44 Power requirement at take-off (kW) 13 15,5 21 25 29 34 Alternator rpm 3000 3000 3000 3000 3000 3000 Weight kg 115 124 144 154 188 209 Dimensions L x W x H in mm 929 x 640 x 915 929 x 640 x 915 929 x 640 x 915 929 x 640 x 915 1135 x 640 x 915 1135 x 640 x 915 Outfit 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A Shockproof sockets 1 x CEE 400 V/16 A 1 x CEE 400 V/32 A 1 x CEE 400 V/32 A 1 x CEE 400 V/32 A 1 x CEE 400 V/63 A 1 x CEE 400 V/63 A • • • • • • • • • • • • • • • • • • • • Residual current device 4-pole fuse protection 2-pole fuse protection Voltmeter Frequency meter amperemeter Operating hour meter • • • • • • • • • • • • Mobile power sources for communities, building and agriculture. PTO GENERATORS A cost-effective power supply possibility is provided by the ENDRESS power take-off generators, as they are simply coupled on to existing farm tractors, municipal tractors or an UNIMOG vehicle. With no need to invest in an additional engine, highly efficient energy sources are available in an emergency or mobile use. G E N E R AT O R S An ENDRESS power take-off generator substantially improves the versatility and utilization of e.g. municipal tractors, provides a secure supply and widens the application capabilities of many electrical appliances and machines. Top rate equipment and quality • RCD with voltmeter and frequency meter. • Robust synchronous generators. • Compound regulation in models with 3000 rpm. • Electronic AVR control in models with 1500 rpm. • 3-point linkage for tractor mounting. • Standard shaft linkage - 450 rpm rated speed. • High protection type IP 44. • Silent transmission runs in oil bath. 47 Types with 1500 rpm EZG 30/4 EZG 40/4 EZG 50/4 511 013 511 014 511 015 EZG 60/4 511 016 synchronous synchronous synchronous synchronous 27,0/21,6 36,5/29,2 46,1/36,9 54,8/43,8 Voltage monitoring module 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 39,0 A 3~ 52,7 A 3~ 66,5 A 3~ 79,1 A 3~ 0,8 0,8 0,8 0,8 50 Hz/IP 44 50 Hz/IP 44 50 Hz/IP 44 50 Hz/IP 44 28 39 48 57 1500 1500 1500 1500 223 345 361 392 1135 x 640 x 915 1172 x 640 x 918 1172 x 640 x 918 1172 x 6440 x 918 1 x 230 V/16 A 1 x 230 V/16 A 1 x CEE 230 V/32 A 1 x 230 V/16 A 1 x CEE V/63 A • • • • • • 1 x CEE 230 V/32 A 1 x CEE 230 V/32 A 1 x CEE 230 V/32 A 1 x CEE 400 V/63 A 1 x CEE 400 V/63 A 1 x CEE 400 V/125 • • • • • • • • • • • • • • • • • • • • • The voltage monitor controls the output voltages to the socket outlets. If the permitted values are undershot or exceeded the electronic unit of the voltage monitor will give out a signal on the circuit relay (protection) and interrupt the output voltage to the socket outlets. Available accessories Earth rod Voltage monitoring module Order No. 342 304 512 000 Adapter CEE 230 V/16 A to Shockproof socket 230 V/16 A 162 004 G E N E R AT O R S ENGINE PUMPS Motor pumps from 600 - 1340 l/min 40 30 48 max. För derhöhe in Mete r Max. delivery head in meters 20 10 0 300 600 900 1200 1500 Förderleistung in Liter/mi n Delivery in liters Tough, robust motor pumps for the harsh use in construction, industry, communities, agriculture and rigging. Using world-wide proven HONDA OHV engines with long service life, easy start-up and high reliability. Top quality materials for all pump components afford full functionality, good performance and little need for maintenance at all times. Due to their robust design, self-priming sewage pumps from ENDRESS allow for a professional transport of clean and heavily soiled water in construction, industry, agriculture and communities. An ENDRESS motor pump ensures independence from electricity and water mains and gives the necessary security every time. The versatile ENDRESS centrifugal pumps are in their element when a high flow rate and high output are required. The following examples are typical applications for which they can be used: Draining of ditches, cable shafts, basements, foundation pits or sewage works, irrigation of fields as well as the emptying and filling of ponds, the drainage of quarries, pits and coal mines. EMP 305 T Depending on the model, centrifugal pumps allow a maximum of 27mm solids through. Both the gyroscope and impeller are well resistant to abrasion and in addition sealing elements which run in an oil bath give the necessary reliability under the most severe of operating conditions. Cleaning is facilitated to a large extent by two swing-out closure blocks. Rotary pumps Engine pumps with decisive advantages OHV engine technology from HONDA. Very high delivery rates. Extremely high insensitivity to impurity laden water. Tough and long life due to a resistance to abrasive materials. • • • • Dirty.water pumps Type EMP 205 EMP 305 EMP 205 T EMP 305 T Order No. 411 000 411 001 411 002 411 003 Max. flow rate 600 l/min (36 m3/h) 930 l/min (55,8 m3/h) 700 l/min (42 m3/h) 1340 l/min (80,4 m3/h) Max. suction lift in m 8m 8m 8m 8m Max. total delivery height 30 m 26 m 30 m 27 m Solids Ø mm 3 mm 7 mm 20 mm 27 mm Connection S/D 2’’ x 2’’ 3’’ x 3’’ 2’’ x 2’’ 3’’ x 3’’ Axie sealing Carbon ceramics Carbon ceramics Silikon carbid Silikon carbid Engine type HONDA GX 120 HONDA GX 160 HONDA GX 160 HONDA GX 240 Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV Engine capacity 118 cm3 163 cm3 163 cm3 242 cm3 Max. output 2,9 kW/3,9 HP 4,1 kW/5,6 HP 4,1 kW/5,6 HP 5,9 kW/8,0 HP Rotation speed rpm 3600 3600 3600 3600 Fuel/Tank capacity (litres) Unleaded petrol/2,5 Unleaded petrol/3,6 Unleaded petrol/3,6 Unleaded petrol/6 Consumption/Running-time1 1,25 l/2 h 1,8 l/2 h 1,7 l/2 h 2,6 l/2,3 h Start-up system Recoil Recoil Recoil Recoil Sound power level LWA2 103 dB(A) 105 dB(A) 106 dB(A) 110 dB(A) Sound pressure level LPA3 78 dB(A) 80 dB(A) 81 dB(A) 95 dB(A) Weight kg 20 29 47 58 Dimensions L x W x H in mm 468 x 352 x 385 505 x 374 x 453 620 x 462 x 481 690 x 485 x 537 Outfit Possible application areas Cut-off when lack of oil, 3 x hose clip, 2 x hose couplings, 1 x stainer, spark plug spanner Rotary pumps for irrigation and drainage, extraction Dirty-water pump of clear or only moderately polluted media for irrigation and drainage in construction industry and agriculture Sturdy dirty-water pump for industrial, municipal and agricultural application Available accessories Suction tube 2’’ 8 m 38 410 Suction tube 2’’ 8 m Pressure tube 2’’ 15 m Pressure tube-extension 2’’ 10 m 38 410 38 407 38 411 Pressure tube 2’’ 15 m 38 407 38 411 38 408 38 414 38 408 38 414 Pressure tube-extension 3’’ 10 m 38 409 38 409 Reduction coupling 3’’ to 2’’ 38 483 38 483 Suction tube, Pressure tube and pressure tube extension are equipped with quick couplings. 1 ENGINE PUMPS EMP 305 G E N E R AT O R S EMP 205 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. 49 BUILDING SITE GENERATORS G E N E R AT O R S Building site generators 13 - 40 kVA 50 ESE 40 DL-B ENDRESS power supply installations meet the EC machine and low voltage directives as well as the requirements of DIN VDE 0100. These sound damped, all-round protected diesel units are made for the rough service on construction sites in. They are equipped with high-quality generators according to VDE 0530 (insulation of class H) and conceived for highest output on harshest operating conditions. • Maintenance intervals only every 1000 working • • • • • • hours with oil cooling. Fittings and hinges of stainless material. Operation with less vibration. Low noise emission. No projecting parts. Constant voltage control AVR (ESE 30/40 DL-B and higher). Service friendly due to modular construction. Order No. 341 102 341 103 DIN-pull eyelet 40 mm for lorry Rear parking supports, (1 pair) Supporting wheel, semi automatic 341 501 341 500 341 502 *reinforced version ST = rigid drawbar all types all types HV = height adjustable drawbar Type ESE 15 DW-B ESE 20 DW-B ESE 30 DL-B Order No. 310 009 310 010 310 002 ESE 40 DL-B 310 003 Max. output [LTP] kVA/kW 13,8/11,0 20,1/16,1 30,0/24,0 41,2/33,0 Constant rating [COP] kVA/kW 13,0/10,4 19,0/15,2 29,0/23,2 39,3/31,4 Alternator type LINZ E1S 13M 4-13 kVA LINZ E1S 13M 4-19 kVA STAMFORD BCI 184 F STAMFORD BCI 184 J Version/Insulation synchronous/class H synchronous/class H synchronous/class H synchronous/class H Nominal voltage 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ Nominal current/cos (phi) 18,8 A 3~/0,8 27,4 A 3~/0,8 41,9 A 3~/0,8 56,7 A 3~/0,8 Frequency 50 Hz 50 Hz 50 Hz 50 Hz Regulation Compound Compound Electronic (± 1,5) Electronic (± 1,5) Engine type DEUTZ D2009 L03 DEUTZ D2009 L04 DEUTZ F4M 2011 DEUTZ F4M 2011 Version 3-cyl. 4-stroke Diesel 4-cyl. 4-stroke Diesel 4-cyl. 4-stroke Diesel 4-cyl. 4-stroke Diesel Aspiration and cooling Suction engine, water-cooled Suction engine, water-cooled Suction engine, oil-cooled Turbo, oil-cooled Engine capacity 1718 cm3 2290 cm3 3110 cm3 3110 cm3 Constant rating [PRP] 14,8 kW 19,1 kW 27,6 kW 36,4 kW Rpm/Regulation 1500/mechanical 1500/mechanical 1500/mechanical 1500/mechanical Fuel/Tank capacity (litres)*1 Diesel/51 Diesel/51 Diesel/51 Diesel/51 Consumption/Running-time1 2,6 l/19,5 h 3,6 l/14 h 5,3 l/9,5 h 7,1 l/7 h Cooling air volume m3/h N/A N/A 1800 2370 Start-up system/Batterie V/Ah E-Start 2 kW/12/45 E-Start 2 kW/12/70 E-Start 3 kW/12/70 E-Start 3 kW/12/70 Sound power level LWA2 96 dB(A) 96 dB(A) 92 dB(A) 92 dB(A) Sound pressure level LPA3 71 dB(A) 71 dB(A) 67 dB(A) 67 dB(A) Weight kg 470 514 916 918 Dimensions L x W x H in mm 1600 x 870 x 1072 1600 x 870 x 1072 2000 x 920 x 1300 2000 x 920 x 1300 Outfit Shockproof sockets 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 x x x x 230 CEE CEE CEE V/16 A 230 V/16 A 400 V/16 A 400 V/32 A x x x x 230 CEE CEE CEE V/16 A 230 V/16 A 400 V/16 A 400 V/32 A x x x x 230 CEE CEE CEE V/16 A 230 V/16 A 400 V/32 A 400 V/63 A x x x x 230 CEE CEE CEE V/16 A 230 V/16 A 400 V/32 A 400 V/63 A Analogue, manual control panel with control units, thermo magnetic automatic circuit breaker with 3-pole protection for 230/400 V, residual current device, oil suction pump (manual), crane loading device, optical fuel gauge Options not retrofit Order No. Emergency power supply 342 400 incl. preheating system, 1 x CEE 400 V socket 342 400 Electronic engine speed governor 342 400 342 400 342 001 342 001 Available accessories: Load transfer switch panel 343 012/E-US 20 343 000/E-US 32 343 001/E-US 45 343 002/E-US 60 Earth rod 343 304 343 304 343 304 342 304 1 2 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. BUILDING SITE GENERATORS Undercarriages according to StVZO: One axle trailer FG 135 ST One axle trailer FG 135 HV G E N E R AT O R S ESE 20 DW-B 51 ! Ideal for leasing and mobile Floodlight system e unit! generator in on Transport securing MOBILE FLOODLIGHT SYSTEMS Floodlight systems Simple handling and safe transport 52 Base turns 360 degrees steplessly EFA 950 S6 MK ENDRESS floodlight systems turn the night into day. For optimal, bright illumination of building sites and many other places. Very versatile and flexible. Due to the top-mounted ENDRESS generator the flood light system does not require mains supply. EFA 950 S6 MK Simple handling by crank. Set-up and extension in one go. Light pole turns 360 degrees steplessly. Self-locking crank winch. Low transportation height. Swivel-type special halogen flood lamps. Fully galvanized chassis acc. to highway code. Adjustable drawbar height. Extending stabilizers for high stability. • • • • • • • • EFA 850 S6 P Pneumatic aluminium telescopic pole, stepless extension. Internal helical cable for more operational safety. Light directly availably at site. Light pole turns 360 degrees steplessly. Maintenance-free anodized aluminium pole. swivel-type special halogen flood lamps. Fully galvanized chassis acc. to highway code. Adjustable drawbar height. Extending stabilizers for high stability. EFA 650 S4, EFA 830 S4, EFA 830 S6, EFA S6 V Maintenance-free aluminum telescoping pole. Integrated drop arrest device. Simple handling by crank. Light pole turns 360 degrees steplessly. Self-locking crank winch. Swivel-type special halogen flood lamps. Fully galvanized chassis acc. to highway code. Adjustable drawbar height • • • • • • FLOODLIGHT SYSTEMS • • • • • • • • • • EFA 850 S6 P MOBILE • • Extending stabilizers for high (except ESE 650 S4). stability. EFA 650 S4 53 NEW NEW Type EFA 650 S4 EFA 830 S4 EFA 830 S6 EFA 850 S6 V EFA 850 S6 P EFA 950 S6 MK Order No. 716 200 716 260 716 280 716 240 716 290 716 230 Light output 4 x 1500 W 4 x 1500 W 6 x 1500 W 6 x 1500 W 6 x 1500 W 6 x 1500 W 3 x switchable 3 x switchable 3 x switchable 3 x switchable 3 x switchable 3 x switchable Max. spotlight height 6,5 m 8,3 m 8,3 m 8,5 m 8,5 m 9,5 m Min. transport height 2,68 m 2,55 m 2,55 m 2,55 m 2,75 m 2,.25 m Lamp poles Pole continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable Version Alu-teleskopic pole Alu-teleskopic pole Alu-teleskopic pole Alu-teleskopic pole Alu-teleskopic pole Steel mast/folding Function mech./hand crank mech./hand crank mech./hand crank pneumatic pneumatic mech./hand crank Undercarriage according to StVZO FG 75 LM FG 100 LM FG 160 LM FG 2500 LM Tandem FG 160 LM FG 160 LM Width in mm 1600 1540 1650 1720 1650 1650 Length over all in mm 3400 4230 5150 5450 5150 5150 Tyres 13’’ 13’’ 14’’ 15’’ 14’’ 14’’ Drawbar rigid height adjustable height adjustable height adjustable height adjustable height adjustable Overrun brake non-braked yes yes yes yes yes Total weight allowed kg 750 1000 1600 2500 1600 1600 Supp. weight allowed kg 50 75 75 100 75 75 Recommended generators ESE 1008 DBS ES Silent ESE 15 DW-B ESE 20 DW-B ESE 30 DL/MS ESE 30 DW-B ESE 20 DW-B ESE ESE ESE ESE ESE 40 DL/MS ESE 65 DW/MS ESE 80 DW/MS ESE 40 DW-B ESE ESE ESE ESE ESE 1308 DBS ES Silent ESE 1204 DHS ES ISO Diesel 30 40 15 20 DL-B DL-B DW/MS DW/MS 30 40 15 20 DL-B DL-B DW/MS DW/MS SUPPLY SYSTEMS P OW E R S U P P LY SYS T E M S Power supply systems 15 - 600 kVA 54 All ENDRESS generators of type series AS and MS meet the new directive Appendix VIII - 2000/14/EC concerning noise emission. Only strong components will make powerful generators! For reasons of technical competence, ENDRESS employs only the high quality industrial engines from DEUTZ and VOLVO-Penta as well as quality alternators from STAMFORD and Mecc Alte. Profi-Power package Oil and water cooled 4-stroke industrial diesel engines secure the professional drive. Due to low fuel and oil consumption as well as the small maintenance effort they are very economical in continuous application. ENDRESS power supply installations are equipped with high-quality, tropicalized* STAMFORD generators** as per VDE 0530 - insulation class H - and are designed for maximum output under the toughest of conditions. Perfect also for leasing. * For safe application in countries with high ambient temperature and air humidity. **Except ESE 15 series One key system, suitable at all doors, ignition lock and fuel tank cap. SUPPLY SYSTEMS P OW E R S U P P LY SYS T E M S Removable cover and large doors for easy cleaning 55 Easy to access, large air filter with exchangeable filter elements. as standard: Large diesel filter with water separator and drain plug. Battery main switch separates the battery from all components of the generator. Manual oil drain pump for simple and quick oil change. SUPPLY SYSTEMS P OW E R S U P P LY SYS T E M S Manual, analogical control panel ENDRESS power generating systems supply constant power, which makes them versatile in use, e.g., for irrigation systems, conveyor belts, cranes, ramming work as well as for building sites and mobile applications. There is no need to connect an automatic emergency supply. Manual control panel The set is started manually by a STARTSTOP key-operated switch. The set can be stopped instantly at the emergency stop button in case of danger. An automatic control unit for the engine and generator functions, 3-pole circuit breaker (4-pole breaker optional) and a differential protection switch are standard for the MS series. Also part of the delivery is a power terminal board for full power withdrawal. A socket combination is available as optional extra. For more information, read on p. 66-67. 56 ENDRESS power supply installations meet the EU machine and low voltage directives as well as the requirements of DIN VDE 0100. Engine output: Continuous output to ISO 3046 (ICN 2) measured at 300 m altitude and +25°C outdoor temperature under variable load. All models meet the German emission control requirements. Analog displays • Voltmeter* • Ammeter* • Frequency meter • Run hour meter • Fuel level • Oil pressure • Engine temperature *3-phase measurement with changeover switch Engine protection functions with alarm Low oil pressure Overtemperature Fuel reserve Battery charge fault • • • • Control functions START-STOP switch with key Emergency STOP button • • Generator protection functions 3-pole main circuit breaker RCD • • Power supply system Terminal board Optional: Profi-Power-Package Socket outlet combination Battery main switch 3-way fuel cock Grounding rod • • (available in series ESE 220 and earlier) Engine protection functions with cut-off Low oil pressure Overtemperature Fuel reserve Battery charge fault • • • • • Optional: Socket outlet combination in series ESE 310 and higher Automatic control panel The control panel is mounted on the base frame (open design) or integrated in the noise cover. It consists of the automatic control of engine and generator functions. Faults are signaled visually and audibly. The circuit breaker (3-pole standard, 4-pole optional) and differential protection are part of the supply. The automatic control panel is prepared for connection of a changeover contactor. (E-US available as accessory item). Integrated functions and components: Measures and displays the following parameters (instantaneous values) by digital display and LED. Programming switch Mode selection 1 Automatic Test T 2 Automatic standard mode A 3 Locked mode Electronic system disabled, required for maintenance 4 Consumer mains supply CR 5 Manual Start enable for manual start-up 6 Manual control of the supply of the consumer by the generator CG Digital display: Warnings (W) and switch-offs (S) • Mains and generator voltages • 3-phase generator current • Generator frequency • Output (kVA, kW, kVAr, cos (phi) • Battery charge voltage and charge • Low oil (W + S) • Overtemperature (W + S) • Failed start (W) • Battery over- and undertvoltage (W) • External STOP (S) • Under- and overfrequency (W + S) • Fuel reserve (W + S) • ELCB (S) • Overload kVA (S) • Shirt circuit (S) • Over- and undervoltage (W + S) • Battery charge fault (W + S) • • • • • • • current Speed Fuels reserve Oil pressure Temperature Run hours, maintenance intervals Starting attempts State and alarm description LEDs Mains availability Mains contactor ON Generator contactor ON Differential protection tripped Generator service Engine alarm status Battery charger ON Battery ON Microcontroller operation Fuel pump filling Engine start Engine stop • • • • • • • • • • • • SUPPLY SYSTEMS ENDRESS emergency generator systems, together with the automatic control unit, automatically restore the power supply if the mains supply fails. The mains voltage is monitored automatically and if a drop is detected in one or several phases, the engine starts automatically - manual starting is also possible. P OW E R S U P P LY SYS T E M S Automatic control panel 57 SUPPLY SYSTEMS P OW E R S U P P LY SYS T E M S DEUTZ oil- and water-cooled engines 15 - 40 kVA The ESE 15 and ESE 20 model series have compact water-cooled DEUTZ industrial engines of the D2009 series. Little maintenance and high quality are typical of these engines which are in worldwide use. The ESE 30 and ESE 40 series are equipped with oil-cooled DEUTZ engines and turbocharger (depending on model). These oil-cooled diesel engines are very reliable and long-lived. Low fuel and oil consumption make them very economical in continuous service. STAMFORD ensure the parallel operation of ohmic and inductive consumers. Designed for maximum output under the toughest of conditions and made according to VDE 0530, insulation class H. The brushless synchronous generators with electronic regulation from Mecc Alte and 58 ESE 80 DW Serial equipment at a glance: Liquid collection pan in AS/MS series models to ensure that no operating fluid is spilled. Engine prewarming system in models with automatic emergency supply. for reliable starting little wear saves fuel low emission level • • • • ESE 15 15,0/12,0 14,3/11,4 Mecc Alte ECO 32 L/4 synchronous/class H 400 V 3~/230 V 1~ 20,6 A 3~/0,8 50 Hz electronic (± 1,5) ESE 20 21,1/16,8 20,1/16,1 STAMFORD BCI 184 E synchronous/class H 400 V 3~/230 V 1~ 29,0 A 3~/0,8 50 Hz electronic (± 1,5) ESE 30 30,0/24,0 29,0/32,2 STAMFORD BCI 184 F synchronous/class H 400 V 3~/230 V 1~ 41,9 A 3~/0,8 50 Hz electronic (± 1,5) ESE 40 41,2/33,0 39,3/31,4 STAMFORD BCI 184 J synchronous/class H 400 V 3~/230 V 1~ 56,7 A 3~/0,8 50 Hz electronic (± 1,5) Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume m3/h Start-up system/Battery V/Ah DEUTZ D2009 L03 3-cyl. 4-stroke Diesel Suction engine/water-cooled 1718 cm3 14,8 1500/mechanical N/A E-Start 2 kW/12/45 DEUTZ D2009 L04 4-cyl. 4-stroke Diesel Suction engine/water-cooled 2290 cm3 19,1 1500/mechanical N/A E-Start 2 kW/12/70 DEUTZ F4M 2011 4-cyl. 4-stroke Diesel Suction engine/oil-cooled 3110 cm3 27,6 1500/mechanical 1800 E-Start 3 kW/12/70 DEUTZ BF4M 2011 4-cyl. 4-stroke Diesel Turbor/oil-cooled 3110 cm3 36,4 1500/mechanical 2370 E-Start 3 kW/12/70 Type series DW/DL Model: Opfen version incl. automatic control panel, preheating system and terminal box Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm ESE 15 DW* 330 200 Diesel/51 2,6 l/19,5 h 410 1600 x 870 x 1000 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, battery pre-charged dryly. * ESE 15 DW * ESE 15 DW ESE 20 DW* 330 201 Diesel/51 3,6 l/14 h 445 1600 x 870 x 1000 ESE 30 DL 330 202 Diesel/90 5,3 l/17 h 714 1800 x 750 x 1570 ESE 40 DL 330 203 Diesel/90 6,9 l/13 h 761 1800 x 750 x 1570 max. output [LTP] kVA/kW 13,8/11,0 · constant rating [PRP] kVA/kW 13,0/10,4 · alternator type: LINZ E1S 13 M 4-13 kVA · regulation: compound max. output [LTP] kVA/kW 20,1/16,1 · constant rating [PRP] kVA/kW 19,0/15,2 · alternator type: LINZ E1S 13 M 4-19 kVA · regulation: compound Type series AS Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LWA3 Weight kg Dimensions L x W x H in mm ESE 15 DW/AS 331 200 Diesel/55 2,8 l/28,5 h 91 dB(A) 66 dB(A) 720 1800 x 830 x 1295 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading devive, soundproof canopy, battery pre-charged dryly. Type series MS ESE 20 DW/AS 331 201 Diesel/55 3,9 l/20,5 h 91 dB(A) 66 dB(A) 785 1800 x 830 x 1295 ESE 30 DL/AS 331 202 Diesel/120 5,6 l/21,5 h 92 dB(A) 67 dB(A) 992 2225 x 1100 x 1290 ESE 40 DL/AS 331 203 Diesel/120 7,5 l/16 h 92 dB(A) 67 dB(A) 1064 2225 x 1100 x 1290 Model: Closed version with key start, analogue control panel, terminal box, soundproof canopy and leak proof tray Type Order No. ESE 15 DW/MS 332 200 Outfit Manual control panel with control unit, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, terminal strip for full collection of power, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly. Load transfer switch Order No. 1 2 343 012/E-US 20 ESE 20 DW/MS 332 201 343 000/E-US 32 ESE 30 DL/MS 332 202 343 001/E-US 45 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. ESE 40 DL/MS 332 203 343 002/E-US 60 SUPPLY SYSTEMS General specifications Type Max. output [LTP] kVA/kW Constant rating [COP] kVA/kW Alternator type Version/Insulation Nominal voltage Nominal current Frequency Regulation P OW E R S U P P LY SYS T E M S MS version Optional: Profi-Power-Package and galvanized base frame 59 SUPPLY SYSTEMS P OW E R S U P P LY SYS T E M S DEUTZ water-cooled engines 60 - 540 kVA DEUTZ water-cooled industrial engines with 4- and 6-cylinder in-line engines of the 2012 and 1013 series are used up to model series ESE 220. Engines with turbocharger and turbocharger/charge air cooler ensure professional drive. The progressive high-pressure injection system and the individual injection pumps reduce the fuel consumption of the engines. DEUTZ water-cooled V8 industrial engines of series 1015 are fitted in the model series ESE 530 and higher series. Electronic engine control ensures optimal steady-state behavior under conditions of peak load (max. 0.3 s). Direct injection, 4-valve technology and environmentally compatible combustion not only improve the operating characteristics but also reduce the operating costs. 60 The brushless synchronous generators with electronic control from Mecc Alte and STAMFORD ensure the parallel operation of ohmic and inductive consumers. Designed for maximum output under the toughest of conditions and made according to VDE 0530, insulation class H. MS version Optional: Profi-Power-Package and galvanized base frame General specifications Type Max. output [LTP] kVA/kW Constant rating [COP] kVA/kW Alternator type Version/Insulation Nominal voltage Nominal current/cos (phi) Frequency Regulation ESE 65 63,0/50,4 57,7/46,1 STAMFORD UCI 224 E synchronous/class H 400 V 3~/230 V 1~ 83 A 3~/0,8 50 Hz electronic (± 1,5) ESE 80 78,5/62,8 74,1/59,3 STAMFORD UCI 224 F synchronous/class H 400 V 3~/230 V 1~ 107 A 3~/0,8 50 Hz electronic (± 1,5) ESE 110 108/86,5 102/82,0 STAMFORD UCI 274 C synchronous/class H 400 V 3~/230 V 1~ 147 A 3~/0,8 50 Hz electronic (± 1,5) Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume Start-up system/Batterie V/Ah DEUTZ BF4M 2012-G2 4-cyl. 4-stroke Diesel Turbo/water-cooled 4040 cm3 52,0 1500/mechanical 5400 E-Start 3 kW/12/95 DEUTZ BF4M 2012 C 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 4040 cm3 66,1 1500/mechanical 4680 E-Start 3 kW/12/95 DEUTZ BF4M 1013 EC 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 4760 cm3 91,1 1500/mechanical 6120 E-Start 3,1 kW/12/145 Type series DW Model: Open version incl. automatic control panel, preheating system a Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm ESE 65 DW 330 204 Diesel/240 10,2 l/23,5 h 865 2200 x 1000 x 1620 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main battery pre-charged dryly. Serial equipment at a glance: Leak proof tray in AS/MS series models to ensure that no operating fluid is spilled. Engine pre-heating system in models with automatic emergency supply. for reliable starting saves fuel little wear low emission level • • • • ESE 80 DW 330 205 Diesel/240 11,7 l/20,5 h 945 2200 x 1000 x 1620 ESE 110 DW 330 206 Diesel/240 16,5 l/14,5 h 1326 2200 x 1000 x 1620 Type series AS Model: Closed version with automatic control panel, preheating system, Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm ESE 65 DW/AS 331 204 Diesel/340 10,2 l/33,4 h 96 dB(A) 71 dB(A) 1300 2710 x 1180 x 1535 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main terminal box for full collection of power, leak proof tray, oil suction pump (manual), crane loading de Type series MS Model: Closed version with key start, analogue control panel, terminal b Type Order No. ESE 65 DW/MS 332 204 Outfit Manual control panel with control unit, main switch ON/OFF, main fuse, emergeny stop switch, resid leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-ch Load transfer switch Order No. 1 2 343 003/E-US 90 ESE 80 DW/AS 331 205 Diesel/340 11,7 l/29 h 96 dB(A) 71 dB(A) 1460 2710 x 1180 x 1535 ESE 80 DW/MS 332 205 343 004/E-US 110 ESE 110 DW/AS 331 206 Diesel/340 16,5 l/20 h 96 dB(A) 72 dB(A) 1900 3000 x 1150 x 1680 ESE 110 DL/MS 332 206 343 005/E-US 200 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. ESE 170 167/134 159/127 STAMFORD UCI 274 E synchronous/class H 400 V 3~/230 V 1~ 230 A 3~/0,8 50 Hz electronic (± 1,5) ESE 195 194/155 186/149 STAMFORD UCI 274 G synchronous/class H 400 V 3~/230 V 1~ 269 A 3~/0,8 50 Hz electronic (± 1,5) ESE 220 220/176 208/166 STAMFORD UCI 274 H synchronous/class H 400 V 3~/230 V 1~ 300 A 3~/0,8 50 Hz electronic (± 1,5) ESE 530 528/422 459/367 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 663 A 3~/0,8 50 Hz electronic (± 1,5) ESE 560 546/437 509/407 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 735 A 3~/0,8 50 Hz electronic (± 1,5) DEUTZ BF6M 1013 E 6-cyl. 4-stroke Diesel Turbo/water-cooled 7150 cm3 117,8 1500/mechanical 9000 E-Start 3,1 kW/12/145 DEUTZ BF6M 1013 EC 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 7150 cm3 138,1 1500/mechanical 10800 E-Start 3,1 kW/12/145 DEUTZ BF6M 1013 FC G2 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 7150 cm3 161,6 1500/electronic 7377 E-Start 3,1 kW/24/2 x 145 DEUTZ BF6M 1013 FC G3 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 7150 cm3 178,6 1500/electronic 8852 E-Start 3,1 kW/24/2 x 145 DEUTZ BF8M 1015 C G2 V 8-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 15900 cm3 391,3 1500/electronic 24120 E-Start 5,4 kW/24/2 x 200 DEUTZ BF8M 1015 CP V 8-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 15900 cm3 433,9 1500/electronic 33120 E-Start 5,4 kW/24/2 x 200 ESE 170 DW 330 208 Diesel/250 24,5 l/10 h 1615 2600 x 1000 x 1620 ESE 195 DW 330 209 Diesel/410 43,7 l/9 h 1980 2650 x 1100x 1965 ESE 220 DW 330 210 Diesel/410 49,2/8 h 2030 2650 x 1100 x 1965 ESE 530 DW 330 211 Diesel/636 74,8 l/8,5 h 3860 3300 x 1800 x 2135 ESE 560 DW 330 212 Diesel/636 84,8 l/7,5 h 3910 3300 x 1800 x 2135 and terminal box ESE 145 DW 330 207 Diesel/250 23 l/11 h 1545 2200 x 1000 x 1600 fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, fuse protection by power switch, , terminal box and leak proof tray ESE 145 DW/AS 331 207 Diesel/340 23 l/14,5 h 97 dB(A) 72 dB(A) 2180 3400 x 1250 x 1680 ESE 170 DW/AS 331 208 Diesel/340 24,5 l/14 h 97 dB(A) 72 dB(A) 2250 3400 x 1250 x 1680 ESE 195 DW/AS 331 209 Diesel/340 32,9 l/10,5 h 97 dB(A) 72 dB(A) 2700 3400 x 1250 x 2070 ESE 220 DW/AS 331 210 Diesel/340 36,8 l/9 h 97 dB(A) 72 dB(A) 2750 3400 x 1250 x 2070 ESE 530 DW/AS 331 211 Diesel/636 74,8 l/8,5 h 98 dB(A) 73 dB(A) 5130 4200 x 1860 x 2250 ESE 560 DW/AS 331 212 Diesel/636 84,8 l/7,5 h 104 dB(A) 73 dB(A) 5155 4200 x 1860 x 2250 fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, fuse protection by power switch, evice, soundproof canopy, battery pre-charged dryly box, soundproof canopy and leak proof tray ESE 145 DW/MS 332 207 ESE 170 DW/MS 332 208 ESE 195 DW/MS 332 209 ESE 220 DW/MS 332 210 dual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, fuse protection by power switch terminal strip for fully collection of power, arged dryly 343 005/E-US 200 343 006/E-US 325 343 006/E-US 325 343 006/E-US 325 343 0109/E-US 1000 343 010/E-US 1000 SUPPLY SYSTEMS ESE 145 142/113 135/108 STAMFORD UCI 274 E synchronous/class H 400 V 3~/230 V 1~ 195 A 3~/0,8 50 Hz electronic (± 1,5) P OW E R S U P P LY SYS T E M S AS version Optional: Socket outlet combination 61 SUPPLY SYSTEMS P OW E R S U P P LY SYS T E M S VOLVO-PENTA water-cooled engines 310 - 600 kVA VOLVO-PENTA water-cooled 4-stroke 6-cyliner in-line engines the powerful diesel engines with turbocharger/charge air cooler provide professional drive. The industrial engines with direct injection and optimized combustion respond quickly in cold weather and have low exhaust emission and high economy of operation. The electronic engine control ensures optimal steady-state behavior under conditions of peak load (max. 0.3 s). put under the toughest of conditions and made according to VDE 0530, insulation class H. Mecc Alte generator, the brushless highperformance synchronous generator with electronic control, ensures the parallel operation of ohmic and inductive consumers. Designed for maximum out- 62 Serial equipment at a glance: • • Leak proof tray in AS series models to ensure that no operating fluid is spilled. Engine pre-heating system in models with automatic emergency supply. for reliable starting little wear saves fuel low emission level • • ESE 275 275/220 252/202 Mecc Alte ECO 38 1L synchronous/class H 400 V 3~/230 V 1~ 363 A 3~/0,8 50 Hz electronic (± 1,5) ESE 330 330/264 315/264 Mecc Alte ECO 38 2L synchronous/class H 400 V 3~/230 V 1~ 454 A 3~/0,8 50 Hz electronic (± 1,5) ESE 415 414/331 378/302 Mecc Alte ECO 40 31 synchronous/class H 400 V 3~/230 V 1~ 546 A 3~/0,8 50 Hz electronic (± 1,5) Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume m3/h Start-up system/Batterie V/Ah VOLVO TAD 734 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 7150 cm3 216 1500/electronic N/A E-Start 5,4 kW/24/2 x 155 VOLVO TAD 941 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 9360 cm3 279 1500/electronic 17410 E-Start 5,4 kW/24/2 x 200 VOLVO TAD 1241 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 12130 cm3 323 1500/electronic 16225 E-Start 6 kW/24/2 x 155 Type series VW Model: Open version incl. automatic control panel, preheating system and terminal box Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm ESE 275 VW 330 224 Diesel/636 39 l/16 h 2108 2950 x 1300 x 1800 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, battery pre-charged drylyn ESE 330 VW 330 215 Diesel/636 48,9 l/13 h 2600 3300 x 1400 x 1887 ESE 415 VW 330 216 Diesel/636 57,8 l/11 h 3050 3300 x 1400 x 1917 Type series AS Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm ESE 275 VW/AS 331 224 Diesel/636 39 l/16 h 97 dB(A) 72 dB(A) 2726 3550 x 1360 x 2016 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly ESE 330 VW/AS 331 215 Diesel/636 48,9 l/13 h 97 dB(A) 72 dB(A) 3200 3950 x 1460 x 2095 ESE 415 VW/AS 331 216 Diesel/636 74,8 l/8,5 h 97 dB(A) 72 dB(A) 3675 3950 x 1460 x 2095 Load transfer switch Order No. 1 2 343 007/E-US 400 343 008/E-US 500 343 009/E-US 700 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. SUPPLY SYSTEMS General specifications Type Max. output [LTP] kVA/kW Constant rating [PRP] kVA/kW Alternator type Building class/Insulation Nominal voltage Nominal current/cos (phi) Frequency Regulation P OW E R S U P P LY SYS T E M S AS version Optional: Socket outlet combination 63 SUPPLY SYSTEMS P OW E R S U P P LY SYS T E M S VOLVO-PENTA water-cooled engines 440 - 600 kVA 64 AS version Optional: Socket outlet combination General specifications Type Max. output [LTP] kVA/kW Constant rating [PRP] kVA/kW Alternator type Building class-/Insulation Nominal voltage Nominal current/cos (phi) Frequency Regulation ESE 450 437/350 411/329 Mecc Alte ECO 40 1S synchronous/class H 400 V 3~/230 V 1~ 593 A 3~/0,8 50 Hz electronic (± 1,5) ESE 510 507/406 461/369 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 665 A 3~/0,8 50 Hz electronic (± 1,5) ESE 560 546/437 505/404 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 729 A 3~/0,8 50 Hz electronic (± 1,5) ESE 590 601/481 571/457 Mecc Alte ECO 40 1L synchronous/class H 400 V 3~/230 V 1~ 824 A 3~/0,8 50 Hz electronic (± 1,5) Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume m3/h Start-up system/Batterie V/Ah VOLVO TAD 1242 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 12130 cm3 352 1500/electronic 19918 E-Start 6 kW/24/2 x 155 VOLVO TAD 1640 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 16120 cm3 393 1500/electronic 16820 E-Start 7 kW/24/2 x 200 VOLVO TAD 1641 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 16120 cm3 430 1500/electronic 21541 E-Start 7 kW/24/2 x 200 VOLVO TAD 1642 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 16120 cm3 485 1500/electronic 21541 E-Start 7 kW/24/2 x 200 Type series VW Model: Open version incl. automatic control panel, preheating system and terminal box Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm ESE 450 VW 330 217 Diesel/636 63,6 l/10 h 3050 3300 x 1400 x 1197 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, battery pre-charged dryly ESE 510 VW 330 218 Diesel/636 66,9 l/9,5 h 3620 3500 x 1500 x 2120 ESE 560 VW 330 219 Diesel/636 74,8 l/8,5 h 3620 3500 x 1500 x 2120 ESE 590 VW 330 220 Diesel/636 84,8 l/7,5 h 3850 3500 x 1500 x 2120 Type series AS Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm ESE 450 VW/AS 331 217 Diesel/636 63,6 l/10 h 97 dB(A) 72 dB(A) 3675 3950 x 1460 x 2095 Outfit Automatic control panel with control unit and integrated battery charger, main switch ON / OFF, main fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly Load transfer switch Order No. 1 2 343 009/E-US 700 ESE 510 VW/AS 331 218 Diesel/636 66,9 l/9,5 h 98 dB(A) 73 dB(A) 4500 4400 x 1560 x 2250 343 010/E-US 700 ESE 560 VW/AS 331 219 Diesel/636 74,8 l/8,5 h 105 dB(A) 80 dB(A) 4500 4400 x 1560 x 2250 343 010/E-US 1000 Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. ESE 590 VW/AS 331 220 Diesel/636 84,8 l/7,5 h 105 dB(A) 80 dB(A) 4890 4400 x 1560 x 2250 343 010/E-US 1000 *with consideration of the charge state of the diesel engine Machines with no-load fans rotary pumps circular saws < < < < < < < < < < Machines < with load fans with high < flywheel moment < compressors < < conveyors < construction < machinery < Machines with < heavy starting < < elevators < heavy < conveyors < construction < machinery < < All above < < mentioned < machines < but with < star-delta< connection < < < ESE 195 ESE 170 ESE 145 ESE 110 ESE 80 ESE 65 ESE 40 Type ESE 30 Power output in kw at 400 V 3~/50 Hz 10 14 19 28 30 38 42 50 67 4,5 6,5 9 13 14 17 19 22 32 3 4,5 6 9 10 12 13 15 21 9 14 18 27 29 36 39 47 64 The above table serve as a guideline for the 1st load connection. Smaller consumers using a serial or ohmic load connection may utilize the generator up to it’s nominal power. The opposite table provides a quick survey of what generator is the right choice for your consumers and your needs. The information is only for guidance and is not exhaustive. The power requirement of consumers depends on several factors and therefore no claims can be based on the table. Abbreviations used in the tables: COP = Continuous power of the unit Continuous power in full power application without a time limit. PRP = Variable continuous power of the unit Continuous power in a varying load operation (average 80% load within 24 hrs.) without time limit. LTP = Limited time unit power A maximum power which can be applied for a maximum of 500 hours per year, whereby in a variable load operation 300 hours should not be exceeded. Explanation of the ENDRESS type code ESE 110 D W / AS S = Noise cover A = Automatic M = Manual W = Water-cooled A = Air-cooled L = Oil-cooled D = DEUTZ V = VOLVO PENTA 110 = Series ESE = ENDRESS GENERATOR AN AID TO CHOICE Application survey* Emergency generating sets P OW E R S U P P LY SYS T E M S Power supply systems - an aid to choice 65 ZUBEHÖR ACCESSORIES P OW E R S U P P LY SYS T E M S Accessory items - description Rental kit Socket combination consisting of: socket outlet combination series ESE 20 AS and MS and earlier 1 x socket outlet with grounding contact 230 V/16 A 1 x CEE 400 V/16 A, 1 x CEE 400 V/32 A From series from ESE 310 AS to ESE 590 AS, consisting of: 1 x CEE 230 V/16 A, 1 x CEE 400 V/16 A 1 x CEE 400 V/32 A, 1 x CEE 400 V/63 A thermomagnetic switch, RCD Socket outlet combination from ESE 30 AS to ESE 220 and MS 1 x socket outlet with grounding contact 230 V/16 A 1 x CEE 230 V/16 A, 1 x CEE 400 V/16 A 1 x CEE 400 V/32 A, 1 x CEE 400 V/63 A Battery main switch separates the battery from all components of the generator. 66 Large diesel filter with water separator and drain plug. Load transfer switch The ENDRESS load transfer contactors are considered as option to the automatic control panel. They consist of a steel cabinet which is delivered separately from the generator. This cabinet is equipped as follows: 2 mechanical and electrically locked contactor pairs for load transfer between mains and generator as well as all necessary auxiliary controls. To ensure easy connection to the automatic control panel at the generator, everything is factory-wired on a terminal block which is integrated in the cabinet. The type of protection of the steel cabinet is IP 45. Includes emergency stop button and 5 m control cable. Earth rod If a generator is used in an RCD environment, the generator must be grounded with a earth rod. One key system suitable at all doors, ignition lock and fuel tank cap. Electronic engine speed governor Automatic fuel pump Fuel pump for automatic or manual filling of the integrated standard tank. Galvanized heavy duty base frame 3-way fuel cock for direct connection of an external fuel tank. Guarantees an optimal transient response at peak load of max. 0.3s ESE 15 DW ESE 15 DW/AS ESE 15 DW/MS ESE 20 DW ESE 20 DW/AS ESE 20 DW/MS ESE 30 DL ESE 30 DL/AS ESE 30 DL/MS ESE 40 DL ESE 40 DL/AS ESE 40 DL/MS ESE 65 DW ESE 65 DW/AS ESE 65 DW/MS ESE 80 DW ESE 80 DW/AS ESE 80 DW/MS ESE 110 DW Residential silencer for fix installation Residual current device All-current sensitive Earth rod Electro-plated base frame ACCESSORIES Modell Exhaust compensator 342 200 342 310 342 311 342 305 342 006 342 001 342 021 342 110 342 111 342 112 342 015 342 016 342 017 342 018 342 019 342 012 342 013 342 014 342 303 Elektronic speed govenor Order No. PMG controller Automatic fuel pump Profi Power Paket (Rental-Kit) Sockets combination Article description P OW E R S U P P LY SYS T E M S Available accessories ESE 110 DW/AS ESE 110 DW/MS ESE 145 DW ESE 145 DW/AS ESE 145 DW/MS ESE 170 DW ESE 170 DW/AS ESE 170 DW/MS ESE 195 DW ESE 195 DW/AS ESE 195 DW/MS ESE 220 DW ESE 220 DW/AS ESE 220 DW/MS ESE 530 DW ESE 530 DW/AS ESE 560 DW ESE 560 DW/AS ESE 310 VW ESE 310 VW/AS ESE 330 VW ESE 330 VW/AS ESE 415 VW ESE 415 VW/AS ESE 450 VW ESE 450 VW/AS ESE 510 VW ESE 510 VW/AS ESE 560 VW ESE 560 VW/AS ESE 590 VW ESE 590 VW/AS 67 ACCESSORIES P OW E R S U P P LY SYS T E M S Accessories Chassis Trailer complying with German road traffic act StVZO All trailers incl. drawbar are fully zinc-coated. The support wheel (semi-automatic/reinforced) is a serial feature. One axle and tandem trailer with rigid or adjustable drawbar equipment with car/truck drawbar eye and lighting are available. All models are delivered with type approval. Type FG 160 ST FG 160 HV FG 2500 ST FG 2500 HV FG 3000 ST FG 3000 HV FG 3500 ST FG 3500 HV Order No. 341 104 341 105 341 110 341 111 341 108 341 109 341 112 341 113 Total weight allowed in kg 1600 1600 2500 2500 3000 3000 3500 3500 One-axle/Tandem One-axle One-axle Tandem Tandem Tandem Tandem Tandem Tandem Drawbar rigid adjustable rigid adjustable rigid adjustable rigid adjustable Overrun brake yes yes yes yes yes yes yes yes 341 503 – 341 503 341 500 341 500 341 500 341 500 341 500 341 500 Available accessories DIN pull eyelet 400 mm for lorry 341 501 Rear parking supports (1 pair) 341 500 341 500 ST = rigid drawbar with ball coupling for car Type series with DEUTZ engines FG 160 ST 68 341 501 ESE 15 AS/MS ESE 20 AS/MS ESE 30 AS/MS ESE 40 AS/MS ESE 65 AS/MS ESE 80 AS/MS • • • • FG 160 HV • • • • ESE 110 AS/MS HV = height adjustable drawbar, zinc-coated with ball coupling for car FG 2500 ST FG 2500 HV • • • • ESE 145 AS/MS FG 3000 ST FG 3000 HV • • ESE 170 AS/MS Type FG 75 ST* FG 75 HV* FG 135 ST FG 135 HV Order No. 341 100 341 101 341 102 341 103 Total weight allowed in kg 750 750 1350 1350 One-axle yes yes yes Drawbar rigid height adjustable rigid height adjustable Overrun brake non-braked non-braked yes yes yes Available accessories DIN pull eyelet 40 mm for lorry 341 501 Supporting wheel, semi-automatic, strengthened Rear parking supports (1 pair) 341 500 * Supporting wheel in front with gripper clamp as standard ESE 1204 DHS ES ISO Diesel ESE 15 DW-B ESE 20 DW-B ESE 30 DL-B ESE 40 DL-B 341 500 341 501 341 502 341 502 341 500 341 500 ST = rigid drawbar with ball coupling for car HV = height adjustable drawbar, zinc-coated with ball coupling for car • • • • • • • • • • FG 3500 ST FG 3500 HV • • • • Generator accessories Remote control Set of wheels The generator and the control unit are connected by a 40 m or 50 m cable. The remote control allows starting und stopping - not retrofitable. Scope of delivery: 2 large inflated wheels, axle, 2 handles and fastening material. Easy assembly with no need for drilling. Crane loading device ACCESSORIES Facilitates the transportation and loading and offers additional protection for engine and alternator. Insulation monitoring According to ISO, a so-called “built ground” is no longer necessary, regardless of which subsurface exists. Consequently you can operate at each place of work without further preparation. Even high-impedance insulation faults are recorded securely and this leads automatically to an immediate shut-down of the voltage. Fuelling system Set of handles A pumping system directly takes in the fuel from a 20-liter can. Cumbersome refueling is not applicable. No spillage of fuel. Uninterruptible can change possible. Scope of delivery: 4 plastic-covered handles and mounting material. Easy assembly with no need for drilling. 3-way fuel cock For direct connection to the fueling system. Cable drum ELT 50/3 acc. to DIN 14680 Welding accessories Scope of delivery: welding mask, metal brush, electrode box, thermo gloves, welding hammer, earth terminal with 5 m cable, electrode holder with 5 m cable. P OW E R G E N E R AT O R S For order numbers, please see the product tables. With 50 m hose line H07 RN-F3 G 2.5. Of that 5 m on the small drum, plug connections according to DIN 49442/49443 (16 A, 2 P + PE), pressure water tight, suitable for DIN power generators. 69 70 The table below provides a quick survey of what generator is the right choice for your consumers and your needs. The information is only for guidance and is not exhaustive. The power requirement of consumers depends on several factors and therefore no claims can be based on the table. To define the optimal generator, add the performance values of the consumers which you want to use simultaneously. Add 10% for ohmic consumers to obtain the correct generator rating. Take at least double the calculated value for inductive consumers such as electric motors. Classic Power-Line Professional-GT-Line Professional-Plus-GT-Line Pages 14 - 15 ESE 1206 DHS-GT ISO ESE 1206 HS-GT ISO ESE 1006 DBS-GT ESE 1006 DBS-GT ES ESE 606 DHS-GT ESE 606 DHS-GT ISO ESE 606 HS-GT ESE 606 HS-GT ISO ESE 506 DHS-GT ESE 506 DHS-GT ISO ESE 404 HS-GT ESE 506 HS-GT ISO ESE 306 HS-GT ESE 206 HS-GT ESE 3000 ESE 40 BS ESE 35 BS ESE 30 BS Pages 16 - 20 ESE 20 BS G E N E R AT O R S AID TO SELECTION Aid to selection Power Household Voltage Lighting 230 V Fridge 230 V 100- 200 Hotplate 230 V 600-2000 <1400 <1700 Fan heater 230 V 1000-2000 <1400 <1700 Hair drier 230 V 400-1500 <1400 Coffee machine 230 V 800-1600 <1400 Drilling maschine 230 V 400-1000 Hammer drill 230 V 600-1600 <1200 <1500 Hand circular saw 230 V 500-1600 <1200 <1500 Angle grinder 230 V 400-2000 <1200 <1500 Hedge shears 230 V 350-1000 Compressor 230 V 1000-2000 Compressor 400 V 1500-3000 Water pump 230 V 500-1500 Water pump VA 100- 500 Electric tools Electric tools 400 V 1500-3000 Circular saw bench 230 V 1000-2500 Circular saw bench 400 V 2500-4000 Inverter wel. device 400 V Ø mm <1100 < 800 <1000 <1200 <1400 <1200 <1000 <1100 <1700 <1200 <1600 <1800 <2400 <1300 <1400 <2300 <1000 <1300 <1100 <1100 <1300 <1900 <1400 <1900 <2100 <2800 2,5 Chopper 230 V 800-2500 < 800 <1000 <1200 <1400 <1200 <1300 <1400 <2100 <2300 Lawn-mower 230 V 800-2000 <1000 <1200 <1400 <1700 <1500 <1500 <1700 Electric motor 3,25 5,0 4,5 <2000 <1800 e.g. in builder’s hoists, stone saws, cranes 0,55 kW 230 V 700 0,75 kW 230 V 1000 1,1 kW 230 V 1500 1,5 kW 230 V/400 V 2000 2,2 kW 230 V/400 V 3000 3,0 kW 230 V/400 V 4000 3~ 1~ 4,0 kW 230 V/400 V 5000 3~ 1~ 5,0 kW 400 V 6250 7,5 kW 400 V 9400 12,0 kW 400 V 15000 1~ 3~ 1~ 1~ 3~ 3~ ESE 1204 DHS ES ISO Diesel ESE 1004 DRS GT ES ISO Diesel ESE 704 DYS GT ES ISO Diesel ESE 604 YS GT ES ISO Diesel ESE 404 YS GT ISO Diesel ESE 608 DYS ES Diesel Silent ESE 608 YS ES Diesel Silent ESE 1308 DHS ES Silent Pages 28 - 29 ESE 1308 HS ES Silent Diesel-Line Pages 25 - 27 ESE 1008 DBS ES Silent Silent Power-Line ESE 608 DBS ES Silent ESE 604 DHG ES Diesel Duplex ESE 808 DBG ES Duplex Silent ESE 1006 DBG Duplex ESE 1006 DBG ES Duplex ESE 604 DHG Duplex ESE 606 DBG Duplex ESE 304 DHG Duplex Pages 21 - 24 ESE 1306 DBG ES Duplex ESE 1308 DBG ES Duplex Silent Duplex-Line ESE 1002 DHG ES Diesel Duplex ESE 1008 DHG ES Diesel Duplex Silent ✔ The black OK sign indicates that the generator output is sufficient for this consumer. AID TO SELECTION ENDRESS products are subject to constant modification. Therefore specifications may change as design revisions take place. All technical specifications and illustrations are without obligation. G E N E R AT O R S < Following this sign is the maximum consumption of the relevant consumer when operating on the appropriate generator. 71 <1600 <1100 <1900 <2400 <2400 <2500 <1300 <1300 <1900 <1600 <1400 <1600 <1600 <2500 <2500 <1900 <1300 3,25 <1400 <2800 <2900 <3000 4,5 4,0 6,5 3,25 <2200 4,5 3,25 <1500 <1500 <2200 <2000 3,25 3,25 5,0 <2400 <1600 <1500 <2300 <2300 4,5 <1300 <2000 <2000 <1600 <2400 1~ 1~ 4,0 4,5 <1600 <1700 1~ 3~ 1~ 1~ 3~ 1~ 3~ 1~ 1~ 3~ 3~ ENDRESS units are subject to a permanent process of further development. Therefore ENDRESS reserves the right to make changes in the sense of a technical improvement. Therefore technical information and illustrations are without obligation. 3~ ENDRESS Elektrogerätebau GmbH Neckartenzlinger Straße 39 D-72658 Bempflingen Telefon +49 - (0 ) -71 23 - 97 37- 0 Telefax +49 - (0 ) -71 23 - 97 37- 50 e-mail [email protected] Internet www.endress-generators.de 901 119/F/1/11.07/ GB Consultation, sale and service by your ENDRESS distribution partner