CDW7 Air Circuit Breaker
Transcription
CDW7 Air Circuit Breaker
S International Catalogue 2011 Delixi Electric: Who are we A global company at your service Delixi was founded in 1984 in Zhejiang province with sales over 1.5BM€,employing more than 15000 people. Delixi created an international Joint Venture in November 2007,named Delixi Electric Ltd., in order to serve you worldwide,with core LV products having the right quality at the right price. Our products are designed for Residential/Building/Energy/infrastructure and Industrial markets.Delixi Electric employs 5200 people world wide. A reliable company serving you with reliable product Dedicated R&D center International quality control of suppliers International quality control of plants Fully automatized distribution center Network of recognized 600 distributors world wide Ⅰ Reliable Quality For more details, please contact your local Delixi Electrc Company. Ⅱ Ⅲ Contents Residual Current Devices 33-36 Accessories for MCB&RCBO 37-40 Control Devices 41-42 Surge Protective Devices 43-47 Distribution Box Low-voltage Low-voltage Distribution Distribution 64-82 48-63 Molded Case Circuit Breaker Final Distribution 19-32 3-18 Miniature Circuit Breakers&Switch Disconnectors Air Circuit Breaker Motor Control & Protection 128-134 86-127 Contactor&Thermal Overload Relay 135-146 Definite-purpose Contactors Relays Management Power Energy Power Energy Management 148-150 151-163 Current Transformer 164-167 Meter Digital Time Switch 168-174 Voltage Stabilizer Industrial Control Components 175-202 Control Signal 203-208 Fuse 209 Cable Connector 210-215 Industrial Plug& Socket 216-220 Copper Terminal Block Series 221 Din-rail 1 Contents Final Distribution Miniature Circuit Breaker & Switch Disconnectors 3-18 Final Distribution CDB6 18mm Miniature Circuit Breaker 4 CDB6s 18mm Miniature Circuit Breaker 8 CDB2 27mm Miniature Circuit Breaker 12 CDB3 Phase-neutral Circuit Breaker 15 CDB5 Switch Disconnector 17 Residual Current Devices 19-32 CDB6LE Residual Current Operated Circuit Breaker 20 CDB6v Residual Current Protection Module 23 CDB2LE Residual Current Operated Circuit Breaker 26 CDB3LE Residual Current Operated Circuit Breaker 29 CDL7 Electromagnetic Type Residual Current Switch 31 Accessories for MCB&RCBO 33-36 SD,OF,MX+OF 33 Busbar 36 Control Devices 37-40 1~5 CDCH8 Modular Contactor 37 CDRT8 Time Relay 39 Surge Protective Devices 41-42 CDY1 41 Surge Protective Devices 1~5 2 Distribution Box 43-47 CDPZ50 Series Lighting Distribution Box 43 JXF Power Distribution Box 45 Miniature Circuit Breaker & Switch Disconnectors Product Overview 18mm MCB 27mm MCB Final Distribution CDB6 CDB6s S 4 In: 1-63A Breaking Capacity: 3/4.5 kA In: 1-63A Breaking Capacity: 4.5/6 kA A 18mm 1P+N MCB CDB3 CDB2 12 In: 63-125A Breaking Capacity: 10kA Switch Disconnectors CDB5 15 In: 6-32A Breaking Capacity: 3kA Accessories page** MX+OF 8 17 In: 20-100A * 33 SD OF 3 CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A Function RoHS CDB6 miniature circuit breaker combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation Final Distribution Order Information Type Breaking Capacity (kA) Rating Width (A) 1P 3 1 3 6 10 16 20 25 32 40 50 63 2 2 2 2 2 2 2 2 2 2 2 4.5 1 3 6 10 16 20 25 32 40 50 63 3 1 3 6 10 16 20 25 32 40 50 63 2P B curve C curve D curve CDB6a1B1 CDB6a1B3 CDB6a1B6 CDB6a1B10 CDB6a1B16 CDB6a1B20 CDB6a1B25 CDB6a1B32 CDB6a1B40 CDB6a1B50 CDB6a1B63 CDB6a1C1 CDB6a1C3 CDB6a1C6 CDB6a1C10 CDB6a1C16 CDB6a1C20 CDB6a1C25 CDB6a1C32 CDB6a1C40 CDB6a1C50 CDB6a1C63 CDB6a1D1 CDB6a1D3 CDB6a1D6 CDB6a1D10 CDB6a1D16 CDB6a1D20 CDB6a1D25 CDB6a1D32 CDB6a1D40 CDB6a1D50 CDB6a1D63 2 2 2 2 2 2 2 2 2 2 2 CDB6L1B1 CDB6L1B3 CDB6L1B6 CDB6L1B10 CDB6L1B16 CDB6L1B20 CDB6L1B25 CDB6L1B32 CDB6L1B40 CDB6L1B50 CDB6L1B63 CDB6L1C1 CDB6L1C3 CDB6L1C6 CDB6L1C10 CDB6L1C16 CDB6L1C20 CDB6L1C25 CDB6L1C32 CDB6L1C40 CDB6L1C50 CDB6L1C63 CDB6L1D1 CDB6L1D3 CDB6L1D6 CDB6L1D10 CDB6L1D16 CDB6L1D20 CDB6L1D25 CDB6L1D32 CDB6L1D40 CDB6L1D50 CDB6L1D63 4 4 4 4 4 4 4 4 4 4 4 CDB6a2B1 CDB6a2B3 CDB6a2B6 CDB6a2B10 CDB6a2B16 CDB6a2B20 CDB6a2B25 CDB6a2B32 CDB6a2B40 CDB6a2B50 CDB6a2B63 CDB6a2C1 CDB6a2C3 CDB6a2C6 CDB6a2C10 CDB6a2C16 CDB6a2C20 CDB6a2C25 CDB6a2C32 CDB6a2C40 CDB6a2C50 CDB6a2C63 CDB6a2D1 CDB6a2D3 CDB6a2D6 CDB6a2D10 CDB6a2D16 CDB6a2D20 CDB6a2D25 CDB6a2D32 CDB6a2D40 CDB6a2D50 CDB6a2D63 Note: Width refers to multiple of 9 mm. 4 Reference CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A RoHS Order Information Type 4P Rating Width (A) Reference B curve C curve D curve 4.5 1 3 6 10 16 20 25 32 40 50 63 4 4 4 4 4 4 4 4 4 4 4 CDB6L2B1 CDB6L2B3 CDB6L2B6 CDB6L2B10 CDB6L2B16 CDB6L2B20 CDB6L2B25 CDB6L2B32 CDB6L2B40 CDB6L2B50 CDB6L2B63 CDB6L2C1 CDB6L2C3 CDB6L2C6 CDB6L2C10 CDB6L2C16 CDB6L2C20 CDB6L2C25 CDB6L2C32 CDB6L2C40 CDB6L2C50 CDB6L2C63 CDB6L2D1 CDB6L2D3 CDB6L2D6 CDB6L2D10 CDB6L2D16 CDB6L2D20 CDB6L2D25 CDB6L2D32 CDB6L2D40 CDB6L2D50 CDB6L2D63 3 1 3 6 10 16 20 25 32 40 50 63 6 6 6 6 6 6 6 6 6 6 6 CDB6a3B1 CDB6a3B3 CDB6a3B6 CDB6a3B10 CDB6a3B16 CDB6a3B20 CDB6a3B25 CDB6a3B32 CDB6a3B40 CDB6a3B50 CDB6a3B63 CDB6a3C1 CDB6a3C3 CDB6a3C6 CDB6a3C10 CDB6a3C16 CDB6a3C20 CDB6a3C25 CDB6a3C32 CDB6a3C40 CDB6a3C50 CDB6a3C63 CDB6a3D1 CDB6a3D3 CDB6a3D6 CDB6a3D10 CDB6a3D16 CDB6a3D20 CDB6a3D25 CDB6a3D32 CDB6a3D40 CDB6a3D50 CDB6a3D63 4.5 1 3 6 10 16 20 25 32 40 50 63 6 6 6 6 6 6 6 6 6 6 6 CDB6L3B1 CDB6L3B3 CDB6L3B6 CDB6L3B10 CDB6L3B16 CDB6L3B20 CDB6L3B25 CDB6L3B32 CDB6L3B40 CDB6L3B50 CDB6L3B63 CDB6L3C1 CDB6L3C3 CDB6L3C6 CDB6L3C10 CDB6L3C16 CDB6L3C20 CDB6L3C25 CDB6L3C32 CDB6L3C40 CDB6L3C50 CDB6L3C63 CDB6L3D1 CDB6L3D3 CDB6L3D6 CDB6L3D10 CDB6L3D16 CDB6L3D20 CDB6L3D25 CDB6L3D32 CDB6L3D40 CDB6L3D50 CDB6L3D63 3 1 3 6 10 16 20 25 32 40 50 63 8 8 8 8 8 8 8 8 8 8 8 CDB6a4B1 CDB6a4B3 CDB6a4B6 CDB6a4B10 CDB6a4B16 CDB6a4B20 CDB6a4B25 CDB6a4B32 CDB6a4B40 CDB6a4B50 CDB6a4B63 CDB6a4C1 CDB6a4C3 CDB6a4C6 CDB6a4C10 CDB6a4C16 CDB6a4C20 CDB6a4C25 CDB6a4C32 CDB6a4C40 CDB6a4C50 CDB6a4C63 CDB6a4D1 CDB6a4D3 CDB6a4D6 CDB6a4D10 CDB6a4D16 CDB6a4D20 CDB6a4D25 CDB6a4D32 CDB6a4D40 CDB6a4D50 CDB6a4D63 Final Distribution 3P Breaking Capacity (kA) Note: Width refers to multiple of 9 mm. 5 CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A RoHS Order Information Type Breaking Capacity (kA) Reference Rating Width (A) 1 8 3 8 6 8 10 8 16 8 20 8 25 8 32 8 40 8 50 8 63 8 Note: Width refers to multiple of 9 mm. Final Distribution 4.5 B curve C curve D curve CDB6L4B1 CDB6L4B3 CDB6L4B6 CDB6L4B10 CDB6L4B16 CDB6L4B20 CDB6L4B25 CDB6L4B32 CDB6L4B40 CDB6L4B50 CDB6L4B63 CDB6L4C1 CDB6L4C3 CDB6L4C6 CDB6L4C10 CDB6L4C16 CDB6L4C20 CDB6L4C25 CDB6L4C32 CDB6L4C40 CDB6L4C50 CDB6L4C63 CDB6L4D1 CDB6L4D3 CDB6L4D6 CDB6L4D10 CDB6L4D16 CDB6L4D20 CDB6L4D25 CDB6L4D32 CDB6L4D40 CDB6L4D50 CDB6L4D63 Technical Data MCB CDB6 18mm Circuit Breaker IEC60898-1 CB, CE, RoHS Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui 1-4P 1,3,6,10,16,20,25,32,40,50,63A 230/400V AC 500V Breaking Capacity Icn Electrical Features Rate current(A) Poles Voltage(V) Breaking capactiy Icn(KA) 1-63 1P 2P, 3P, 4P 230/400 400 3/4.5 3/4.5 Tripping Curve(see following tripping curve pictures) B Curve:the magnetic release operates between 3 and 5 In C Curve:the magnetic release operates between 5 and 10 In D Curve:the magnetic release operates between 10 and 14 In Mechanical Features 2 Connection Installation Up to 25mm cables Rate Current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 1-63 M5 2.5 4.5 Mounting Accessories 35mm Din-rail Contact Accessory Fault-indicating Accessory Shunt -trip release 6 4000 times 10000 times 2 treatment 2 ~ 40℃ -5℃~+ Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature OF SD MX+OF CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A RoHS Tripping Curve CDB6 Miniature Circuit Breaker Final Distribution Overall Dimensions Accessory The Sketch Map of Installation with Breakers SD OF CDB6 MX+OF 7 CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A Function CDB6s miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation Final Distribution Order Information Type Rating Width (A) 1P 1 2P Reference B curve C curve D curve 2 CDB6s1B1 CDB6s1C1 CDB6s1D1 2 2 CDB6s1B2 CDB6s1C2 CDB6s1D2 3 2 CDB6s1B3 CDB6s1C3 CDB6s1D3 4 2 CDB6s1B4 CDB6s1C4 CDB6s1D4 5 2 CDB6s1B5 CDB6s1C5 CDB6s1D5 6 2 CDB6s1B6 CDB6s1C6 CDB6s1D6 8 2 CDB6s1B8 CDB6s1C8 CDB6s1D8 10 2 CDB6s1B10 CDB6s1C10 CDB6s1D10 13 2 CDB6s1B13 CDB6s1C13 CDB6s1D13 16 2 CDB6s1B16 CDB6s1C16 CDB6s1D16 20 2 CDB6s1B20 CDB6s1C20 CDB6s1D20 25 2 CDB6s1B25 CDB6s1C25 CDB6s1D25 32 2 CDB6s1B32 CDB6s1C32 CDB6s1D32 40 2 CDB6s1B40 CDB6s1C40 CDB6s1D40 50 2 CDB6s1B50 CDB6s1C50 CDB6s1D50 63 2 CDB6s1B63 CDB6s1C63 CDB6s1D63 1 4 CDB6s2B1 CDB6s2C1 CDB6s2D1 2 4 CDB6s2B2 CDB6s2C2 CDB6s2D2 3 4 CDB6s2B3 CDB6s2C3 CDB6s2D3 4 4 CDB6s2B4 CDB6s2C4 CDB6s2D4 5 4 CDB6s2B5 CDB6s2C5 CDB6s2D5 6 4 CDB6s2B6 CDB6s2C6 CDB6s2D6 8 4 CDB6s2B8 CDB6s2C8 CDB6s2D8 10 4 CDB6s2B10 CDB6s2C10 CDB6s2D10 13 4 CDB6s2B13 CDB6s2C13 CDB6s2D13 16 4 CDB6s2B16 CDB6s2C16 CDB6s2D16 20 4 CDB6s2B20 CDB6s2C20 CDB6s2D20 25 4 CDB6s2B25 CDB6s2C25 CDB6s2D25 32 4 CDB6s2B32 CDB6s2C32 CDB6s2D32 40 4 CDB6s2B40 CDB6s2C40 CDB6s2D40 50 4 CDB6s2B50 CDB6s2C50 CDB6s2D50 63 4 CDB6s2B63 CDB6s2C63 CDB6s2D63 Note: Width refers to multiple of 9 mm. 8 CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A Order Information Rating Width (A) Reference B curve C curve D curve 3P 1 6 CDB6s3B1 CDB6s3C1 CDB6s3D1 2 6 CDB6s3B2 CDB6s3C2 CDB6s3D2 3 6 CDB6s3B3 CDB6s3C3 CDB6s3D3 4 6 CDB6s3B4 CDB6s3C4 CDB6s3D4 5 6 CDB6s3B5 CDB6s3C5 CDB6s3D5 6 6 CDB6s3B6 CDB6s3C6 CDB6s3D6 8 6 CDB6s3B8 CDB6s3C8 CDB6s3D8 10 6 CDB6s3B10 CDB6s3C10 CDB6s3D10 13 6 CDB6s3B13 CDB6s3C13 CDB6s3D13 16 6 CDB6s3B16 CDB6s3C16 CDB6s3D16 20 6 CDB6s3B20 CDB6s3C20 CDB6s3D20 25 6 CDB6s3B25 CDB6s3C25 CDB6s3D25 32 6 CDB6s3B32 CDB6s3C32 CDB6s3D32 40 6 CDB6s3B40 CDB6s3C40 CDB6s3D40 50 6 CDB6s3B50 CDB6s3C50 CDB6s3D50 63 6 CDB6s3B63 CDB6s3C63 CDB6s3D63 1 8 CDB6s4B1 CDB6s4C1 CDB6s4D1 2 8 CDB6s4B2 CDB6s4C2 CDB6s4D2 3 8 CDB6s4B3 CDB6s4C3 CDB6s4D3 4 8 CDB6s4B4 CDB6s4C4 CDB6s4D4 5 8 CDB6s4B5 CDB6s4C5 CDB6s4D5 6 8 CDB6s4B6 CDB6s4C6 CDB6s4D6 8 8 CDB6s4B8 CDB6s4C8 CDB6s4D8 10 8 CDB6s4B10 CDB6s4C10 CDB6s4D10 13 8 CDB6s4B13 CDB6s4C13 CDB6s4D13 16 8 CDB6s4B16 CDB6s4C16 CDB6s4D16 20 8 CDB6s4B20 CDB6s4C20 CDB6s4D20 25 8 CDB6s4B25 CDB6s4C25 CDB6s4D25 32 8 CDB6s4B32 CDB6s4C32 CDB6s4D32 40 8 CDB6s4B40 CDB6s4C40 CDB6s4D40 50 8 CDB6s4B50 CDB6s4C50 CDB6s4D50 63 8 CDB6s4B63 CDB6s4C63 CDB6s4D63 4P Final Distribution Type Note: Width refers to multiple of 9 mm. 9 CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A Technical Data MCB CDB6s 18mm Circuit Breaker Final Distribution Standard IEC 60898-1 Certitication KEMA CB CE RoHS poles 1-4P Rated Current In 1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63 Rated Voltage Ue 230/400V AC Insulation Voltage Ui 500V AC Breaking Capacity Icn Electrical Features Rate current(A) Breaking 1-40 6 B,C 1P 2P, 3P, 4P 230/400 400 50,63 4.5 B,C 1P 2P, 3P, 4P 230/400 400 1-63 4.5 D 1P 2P, 3P, 4P 230/400 400 Type Poles Voltage capacity lcn(kA) (V) Tripping Curve ( see following tripping curve pictures) B curve;the magnetic release operates between 3 and 5 In C curve;the magnetic release operates between 5 and 10 In D curve;the magnetic release operates between 10 and 14 In Mechanical Features Electrical Durability 4000 times Mechanical Durability 10000 times Protection Degree 2 Tropicalization treatment 2 Ambient Temperture ~ + 40℃ -5℃~ Connection Installation Up to 25mm2 cables Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 1-63 M5 2.5 4.5 Mounting Accessories 10 35mm Din-rail Contact Accessory OF Fault-indicating Accessory SD Shunt-trip Release MX+OF CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A Tripping Curves Final Distribution Overall Dimensions Unit: mm 88 max : 67.21–0.43 Accessory SD OF CDB6s MX+OF 11 CDB2 27mm Miniature Circuit Breaker Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Function CDB2 miniature circuit breaker combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation Final Distribution Order Information 12 Type Rating (A) Width (in mod.of 9mm) Reference C curve D curve 1P 63 80 100 125 3 3 3 3 CDB2H1C63 CDB2H1C80 CDB2H1C100 CDB2H1C125 CDB2H1D63 CDB2H1D80 CDB2H1D100 CDB2H1D125 2P 63 80 100 125 6 6 6 6 CDB2H2C63 CDB2H2C80 CDB2H2C100 CDB2H2C125 CDB2H2D63 CDB2H2D80 CDB2H2D100 CDB2H2D125 3P 63 80 100 125 9 9 9 9 CDB2H3C63 CDB2H3C80 CDB2H3C100 CDB2H3C125 CDB2H3D63 CDB2H3D80 CDB2H3D100 CDB2H3D125 4P 63 80 100 125 12 12 12 12 CDB2H4C63 CDB2H4C80 CDB2H4C100 CDB2H4C125 CDB2H4D63 CDB2H4D80 CDB2H4D100 CDB2H4D125 CDB2 27mm Miniature Circuit Breaker Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Technical Data MCB CDB2 27mm Circuit Breaker IEC60947-2 Certification CB, SEMKO, CE Poles 1-4P Rated Current In 63,80,100,125A Rated Voltage Ue 230/400V AC Insulation Voltage Ui 500V Electrical Final Distribution Standard Breaking Capacity Icn Features Rating (A) Poles Voltage (V) Breaking capacity (kA) 63~125 1P 2P,3P,4P 230 400 10 10 Tripping Curve (see following tripping curve pictures) C curve the magnetic release operates between 5 and 10 In D curve the magnetic release operates between 10 and 14 In Electrical Durability Mechanical Features Mechanical Durability Protection Degree 2 Tropicalization treatment 2 Ambient Temperature -5℃~+40℃ ~ Up to 50mm cables 2 Connection Installation Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 63-125 M7 4 5.5 Mounting Accessories 35mm Din-rail Contact Accessory: OF Shunt-trip Release: MX+OF 13 CDB2 27mm Miniature Circuit Breaker Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Tripping Curves Final Distribution Overall Dimensions Accessories MX+OF 14 OF CDB2 CDB3 Phase-neutral Circuit Breaker Standard: IEC 60898-1 Trip Curve: C curves Breaking Capacity: 3000A Function CDB3 phase-neutral circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation 1P+N Final Distribution Order Information 6 2 CDB3a5C6 10 2 CDB3a5C10 16 2 CDB3a5C16 20 2 CDB3a5C20 25 2 CDB3a5C25 32 2 CDB3a5C32 Technical Data CDB3 18mm Circuit Breaker MCB Electrical Features Standard IEC60898-1 Certification CE Poles 1P+N Rated Current In 6,10,16,20,25,32A Rated Voltage Ue 230V AC Insulation Voltage Ui 500V Breaking Capacity Icn 3KA Tripping Curve (see following tripping curve pictures) C curve:the magnetic release operates between 5 and 10In Mechanical Features Electrical Durability 4000 times Mechanical Durability 16000 times Protection Degree 2 Tropicalization treatment 2 Ambient Temperature -5℃~+40℃ Up to 10mm cables 2 Connection Installation Rate current(A) 6-32 Mounting Screw M4 Rated Torque (Nm) 2 Limiting Torque (Nm) 3 35mm Din-rail 15 CDB3 Phase-neutral Circuit Breaker Standard: IEC 60898-1 Trip Curve: C curves Breaking Capacity: 3000A Tripping Curves 10000 5000 1h 2000 1000 Final Distribution 500 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0.001 0.5 1 2 3 4 5 7 10 20 30 50 70 100 Overall Dimensions 16 200 CDB5 Switch Disconnector Standard: IEC 60947-3 Function CDB5 switch disconnectorscombine combinethe thefollowing followingfunctions: functions: Making and breaking normal load circuits Isolation Order Information Voltage (V) Rating (A) Width (in mod.of 9mm) Reference 1P 230 20 32 63 100 2 2 2 2 CDB5120 CDB5132 CDB5163 CDB51100 2P 400 20 32 63 100 4 4 4 4 CDB5220 CDB5232 CDB5263 CDB52100 3P 400 20 32 63 100 6 6 6 6 CDB5320 CDB5332 CDB5363 CDB53100 4P 400 20 32 63 100 8 8 8 8 CDB5420 CDB5432 CDB5463 CDB54100 Final Distribution Type 17 CDB5 Switch Disconnector Standard: IEC 60947-3 Technical Data CDB5 Switch Disconnector Switch Disconnector Final Distribution Electrical Features Mechanical Features Standard IEC60947-3 Poles 1-4P Rated Current In 20,32,63,100A Rated Voltage Ue 230/400V AC Insulation Voltage Ui 500V Rated Short-circuit Making Capacity 1066A(Ie:20~63A) Short-time Withstand 756A(Ie:20~63A) Capacity for 1s 1200A(Ie:100A),1s Electrical Durability 1500 times Mechanical Durability 8500 times Protection Degree 2 Ambient Temperature -5℃~+40℃ Tropicalization treatment 2 1692A(Ie:100A), Peak current Storage Temperature Up to 50mm cables Connection Installation Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 20-100 M7 4 5.5 Mounting Overall Dimensions 18 -25℃~+55℃ 2 35mm Din-rail Residual Current Devices Overview Add-on RCD 18mm RCBO Final Distribution CDB6LE 20 CDB6v 23 Sensitivity: 30,50,100,200,300mA Sensitivity: 30,100,300mA In: 6-60A In: V32A, V63A Breaking Capacity: 3kA Poles: 1P+N, 2P, 3P, 3P+N, 4P Poles: 1P+N, 2P, 3P, 3P+N, 4P 27mm RCBO CDB2LE Phase-neutral RCBO 26 Sensitivity: 30,100,300mA In: 63-100A Breaking Capacity: 10kA Poles: 1P+N, 2P, 3P, 3P+N, 4P CDB3LE 29 Sensitivity: 30mA In: 6-40A Breaking Capacity: 4.5kA Poles: 1P+N RCCB CDL7 31 Sensitivity:10,30,100,300mA In: 25-100A Poles: 2P,4P 19 CDB6LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA Function Final Distribution CDB6LE electronic type residual current operated circuit breakers combine the following functions: Overload protection Protection against short-circuit current Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation Order Information Type Voltage (V) Sensitivity (mA) Rating (A) Width Reference C curve 1P+N 230 30 6 10 16 20 25 32 40 50 60 5 5 5 5 5 5 6 6 6 CDB6LEa1C6S CDB6LEa1C10S CDB6LEa1C16S CDB6LEa1C20S CDB6LEa1C25S CDB6LEa1C32S CDB6LEa1C40S CDB6LEa1C50S CDB6LEa1C60S CDB6LEa1D6S CDB6LEa1D10S CDB6LEa1D16S CDB6LEa1D20S CDB6LEa1D25S CDB6LEa1D32S CDB6LEa1D40S CDB6LEa1D50S CDB6LEa1D60S 2P 230 30 6 10 16 20 25 32 40 50 60 7 7 7 7 7 7 8 8 8 CDB6LEa2C6S CDB6LEa2C10S CDB6LEa2C16S CDB6LEa2C20S CDB6LEa2C25S CDB6LEa2C32S CDB6LEa2C40S CDB6LEa2C50S CDB6LEa2C60S CDB6LEa2D6S CDB6LEa2D10S CDB6LEa2D16S CDB6LEa2D20S CDB6LEa2D25S CDB6LEa2D32S CDB6LEa2D40S CDB6LEa2D50S CDB6LEa2D60S 3P 400 30 6 10 16 20 25 32 40 50 60 10 10 10 10 10 10 12 12 12 CDB6LEa3C6S CDB6LEa3C10S CDB6LEa3C16S CDB6LEa3C20S CDB6LEa3C25S CDB6LEa3C32S CDB6LEa3C40S CDB6LEa3C50S CDB6LEa3C60S CDB6LEa3D6S CDB6LEa3D10S CDB6LEa3D16S CDB6LEa3D20S CDB6LEa3D25S CDB6LEa3D32S CDB6LEa3D40S CDB6LEa3D50S CDB6LEa3D60S 3P+N 400 30 6 10 16 20 25 32 40 50 60 11 11 11 11 11 11 14 14 14 CDB6LEa6C6S CDB6LEa6C10S CDB6LEa6C16S CDB6LEa6C20S CDB6LEa6C25S CDB6LEa6C32S CDB6LEa6C40S CDB6LEa6C50S CDB6LEa6C60S CDB6LEa6D6S CDB6LEa6D10S CDB6LEa6D16S CDB6LEa6D20S CDB6LEa6D25S CDB6LEa6D32S CDB6LEa6D40S CDB6LEa6D50S CDB6LEa6D60S D curve Note: 1. Width refers to multiple of 9 mm. 2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with "W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T". 20 CDB6LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA Order Information Voltage (V) Sensitivity (mA) Rating (A) Width 4P 400 30 6 10 16 20 25 32 40 50 60 13 13 13 13 13 13 16 16 16 Reference C curve D curve CDB6LEa4C6S CDB6LEa4C10S CDB6LEa4C16S CDB6LEa4C20S CDB6LEa4C25S CDB6LEa4C32S CDB6LEa4C40S CDB6LEa4C50S CDB6LEa4C60S CDB6LEa4D6S CDB6LEa4D10S CDB6LEa4D16S CDB6LEa4D20S CDB6LEa4D25S CDB6LEa4D32S CDB6LEa4D40S CDB6LEa4D50S CDB6LEa4D60S Note: 1. Width refers to multiple of 9 mm. 2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with "W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T". Technical Data CDB6LE Residual Current Operated Circuit Breaker RCBO Electronic Type IEC 61009-1 AC Poles 1P+N,2P,3P,3P+N,4P Rated Current In 6,10,16,20,25,32,40,50,60A Standard Electrical Features Rated Voltage Ue 230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P Insulation Voltage Ui 500V Breaking Capacity 3KA Sensitivity 30,50,100,200,300mA Tripping Curve(see following tripping curve pictures) C curve:the magnetic release operates between 5 and 10 D curve:the magnetic release operates between 10 and 14 Mechanical Features Electrical Durability 2000 times Mechanical Durability 2000 times Protection Degree 2 Tropicalization treatment 2 -5℃~+40℃ Ambient Temperature 6-32A,Up to 16mm cables, 40-60A,Up to 25mm2 cables Screw Rated Torque Limiting Torque Connection 2 Rate current(A) Installation Mounting Accessories (Nm) (Nm) 6-32 M4 2.0 3.0 40-60 M5 2.5 4.5 35mm Din-rail OF Contact Accessory: Fault-indicating Accessory: SD 21 Final Distribution Type CDB6LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA Tripping Curves Final Distribution Overall Dimensions Accessories SD 22 OF CDB6LE CDB6v Residual Current Protection Module Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Function CDB6v can be assembled with CDB6s to be residual current breaker overcurrent Protection of persons against indirect contacting Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products marked "G" Final Distribution Order Information Frame Type Voltage (V) Sensitivity (mA) Width Reference V32 1P+N 230 30 5 CDB6v321N 100 5 CDB6v321NR100 300 5 CDB6v321NR300 30 7 CDB6v322P 100 7 CDB6v322PR100 300 7 CDB6v322PR300 30 10 CDB6v323P 100 10 CDB6v323PR100 300 10 CDB6v323PR300 30 11 CDB6v323N 100 11 CDB6v323NR100 300 11 CDB6v323NR300 30 13 CDB6v324P 100 13 CDB6v324PR100 300 13 CDB6v324PR300 30 6 CDB6v631N 100 6 CDB6v631NR100 2P 400 3P 3P+N 4P V63 1P+N 2P 230 400 3P 3P+N 4P Note: Width refers to mutultiple of 9mm. 300 6 CDB6v631NR300 30 8 CDB6v632P 100 8 CDB6v632PR100 300 8 CDB6v632PR300 30 12 CDB6v633P 100 12 CDB6v633PR100 300 12 CDB6v633PR300 30 14 CDB6v633N 100 14 CDB6v633NR100 300 14 CDB6v633NR300 30 16 CDB6v634P 100 16 CDB6v634PR100 300 16 CDB6v634PR300 23 CDB6v Residual Current Protection Module Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Technical Data RCD Final Distribution Electrical Features Mechanical Features CDB6v Residual Current Protection Module Standard IEC61009-1 Electronic Type AC Poles 1P+N, 2P, 3P, 3P+N, 4P Rated Current In V32 In≤32A;V63 In≤63A Rated Voltage Ue 230/400V AC Rated Insulation Voltage 500V A Breaking Capacity after CDB6s assembled with reference to CDB6s parameters Sensitivity 30,100,300mA Tripping Indication On CDB6v is a residual opening current indication, which distinguish residual current from other faults Manual Control Manual control:allows for two kinds of reset CDB6v resets at the same time with breaker CDB6v resets before breaker “G” products offer overvoltage protection 280V±5% AC,applicable to products with 1P+N and 2P Electrical Durability 2000 times(In≤25A) 1000times(In>25A) 1000 times(In>25A) Mechanical Durability 2000 times Protection Degree IP20 Tropicaliation treatrment 2 Ambient Temperature ~ -5℃~+40℃ 2 -Up to 16mm cables(V32) 2 -Up to 25mm cables(V63) Connection Installation 24 Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) V32 V63 M4 M5 2.2 2.5 3.0 4.5 CDB6v Residual Current Protection Module Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Overall Dimensions Final Distribution Pole V32 V63 1P+N 45±0.32 54±0.37 2P 63±0.37 72±0.43 3P 90±0.5 108±0.57 3P+N 99±0.5 126±0.64 4P 117±0.57 144±0.72 Assembly + CDB6v can be assembled with CDB6s to be residual current breaker overcurrent Protection of persons against indirect contacting Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products marked“G” 25 CDB2LE Residual Current Operated Circuit Breaker Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA Function CDB2LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Protection of electrical installations against insulation faults (fire hazard, etc) Isolation Final Distribution Order Information Sensitivity Rating (A) (mA) Reference C curve D curve 6 30 30 30 100 100 100 300 300 300 63 80 100 63 80 100 63 80 100 CDB2LEH1C63S CDB2LEH1C80S CDB2LEH1C100S CDB2LEH1C63Y CDB2LEH1C80Y CDB2LEH1C100Y CDB2LEH1C63T CDB2LEH1C80T CDB2LEH1C100T CDB2LEH1D63S CDB2LEH1D80S CDB2LEH1D100S CDB2LEH1D63Y CDB2LEH1D80Y CDB2LEH1D100Y CDB2LEH1D63T CDB2LEH1D80T CDB2LEH1D100T 2P 9 30 30 30 100 100 100 300 300 300 63 80 100 63 80 100 63 80 100 CDB2LEH2C63S CDB2LEH2C80S CDB2LEH2C100S CDB2LEH2C63Y CDB2LEH2C80Y CDB2LEH2C100Y CDB2LEH2C63T CDB2LEH2C80T CDB2LEH2C100T CDB2LEH2D63S CDB2LEH2D80S CDB2LEH2D100S CDB2LEH2D63Y CDB2LEH2D80Y CDB2LEH2D100Y CDB2LEH2D63T CDB2LEH2D80T CDB2LEH2D100T 3P 12 30 30 30 100 100 100 300 300 300 63 80 100 63 80 100 63 80 100 CDB2LEH3C63S CDB2LEH3C80S CDB2LEH3C100S CDB2LEH3C63Y CDB2LEH3C80Y CDB2LEH3C100Y CDB2LEH3C63T CDB2LEH3C80T CDB2LEH3C100T CDB2LEH3D63S CDB2LEH3D80S CDB2LEH3D100S CDB2LEH3D63Y CDB2LEH3D80Y CDB2LEH3D100Y CDB2LEH3D63T CDB2LEH3D80T CDB2LEH3D100T 3P+N 12 30 30 30 100 100 100 300 300 300 63 80 100 63 80 100 63 80 100 CDB2LEH6C63S CDB2LEH6C80S CDB2LEH6C100S CDB2LEH6C63Y CDB2LEH6C80Y CDB2LEH6C100Y CDB2LEH6C63T CDB2LEH6C80T CDB2LEH6C100T CDB2LEH6D63S CDB2LEH6D80S CDB2LEH6D100S CDB2LEH6D63Y CDB2LEH6D80Y CDB2LEH6D100Y CDB2LEH6D63T CDB2LEH6D80T CDB2LEH6D100T Type Width 1P+N Note: Width refers to multiple of 9mm . 26 CDB2LE Residual Current Operated Circuit Breaker Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA Order Information Type Sensitivity Rating (A) (mA) Width 4P 15 63 80 100 63 80 100 63 80 100 D curve CDB2LEH4C63S CDB2LEH4C80S CDB2LEH4C100S CDB2LEH4C63Y CDB2LEH4C80Y CDB2LEH4C100Y CDB2LEH4C63T CDB2LEH4C80T CDB2LEH4C100T CDB2LEH4D63S CDB2LEH4D80S CDB2LEH4D100S CDB2LEH4D63Y CDB2LEH4D80Y CDB2LEH4D100Y CDB2LEH4D63T CDB2LEH4D80T CDB2LEH4D100T Note: Width refers to multiple of 9mm . Technical Data RCBO Electrical Features CDB2LE Residual Current Operated Circuit Breake r Standard IEC60947-2 Electronic Type AC Poles 1P+N,2P,3P,3P+N,4P Rated Current In 63,80,100A Rated Voltage Ue 230V for 1P+N; 400V for 2P/3P/3P+N/4P Insulation Voltage Ui 500V Breaking Capacity 10KA Sensitivity 30,100,300mA Tripping Curve ( see following tripping curve pictures) C curve:the magnetic release operated between 5 and 10 In D curve:the magnetic release operated between 10 and 14 In Mechanical Features Electrical Durability 1500 times Mechanical Durability 8500 times Protection Degree 2 Tropicalization treatment 2 Ambient Temperature -5℃~+40℃ Connection Installation Accessories Up to 50mm2 cables Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 63-100 M7 4 5.5 Contact Accessory: OF Shunt -trip Release: MX+OF 27 Final Distribution 30 30 30 100 100 100 300 300 300 Reference C curve CDB2LE Residual Current Operated Circuit Breaker Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA Tripping Curve e Final Distribution Overall Dimensions Accessories MX+OF 28 OF CDB2LE CDB3LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA Function Order Information Type Width (mm) Rating(A) 1P+N 36 6 10 16 20 25 32 40 Reference C curve CDB3LEL5C6S CDB3LEL5C10S CDB3LEL5C16S CDB3LEL5C20S CDB3LEL5C25S CDB3LEL5C32S CDB3LEL5C40S Technical Data CDB3LE Residual Current Operated Circuit Breaker RCBO Electrical Features Standard IEC61009-1 Electronic Type AC Poles 1P+N Rated Current In 6,10,16,20,25,32,40A Rated Voltage Ue 230V AC Insulation Voltage Ui 500V Breaking Capacity 4.5KA Sensitivity 30mA Tripping Curve (see following tripping curve pictures) C curve:the magnetic release operates between 5 and 10 In Mechanical Features Electrical Durability 2000 times Mechanical Durability 2000 times Protection Degree 2 Tropicalization treatment 2 Ambient Temperature -5℃~+40℃ 2 Connection Installation Mounting Up to 16mm cables Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 6-40 M5 2.5 4.5 35mm Din-rail 29 Final Distribution CDB3LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc) Isolation CDB3LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA Tripping Curve Final Distribution Overall Dimensions 30 CDL7 Electromagnetic Type Residual Current Switch Standard: IEC 61008 RCCB Type: A , AC Sensitivity: 10, 30, 100, 300mA Function CDL7 electromagnetic type residual current switch combine the following functions: Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Order Information 4 10 16 25 40 63 80 100 4P 8 10 16 25 40 63 80 100 10 30 100 300 10 30 100 300 10 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 CDL7210LA CDL7210SA CDL7210YA CDL7210TA CDL7216LA CDL7216SA CDL7216YA CDL7216TA CDL7225LA CDL7225SA CDL7225YA CDL7225TA CDL7240SA CDL7240YA CDL7240TA CDL7263SA CDL7263YA CDL7263TA CDL7280SA CDL7280YA CDL7280TA CDL72100SA CDL72100YA CDL72100TA CDL7210LC CDL7210SC CDL7210YC CDL7210TC CDL7216LC CDL7216SC CDL7216YC CDL7216TC CDL7225LC CDL7225SC CDL7225YC CDL7225TC CDL7240SC CDL7240YC CDL7240TC CDL7263SC CDL7263YC CDL7263TC CDL7280SC CDL7280YC CDL7280TC CDL72100SC CDL72100YC CDL72100TC 10 30 100 300 10 30 100 300 10 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 CDL7410LA CDL7410SA CDL7410YA CDL7410TA CDL7416LA CDL7416SA CDL7416YA CDL7416TA CDL7425LA CDL7425SA CDL7425YA CDL7425TA CDL7440SA CDL7440YA CDL7440TA CDL7463SA CDL7463YA CDL7463TA CDL7480SA CDL7480YA CDL7480TA CDL74100SA CDL74100YA CDL74100TA CDL7410LC CDL7410SC CDL7410YC CDL7410TC CDL7416LC CDL7416SC CDL7416YC CDL7416TC CDL7425LC CDL7425SC CDL7425YC CDL7425TC CDL7440SC CDL7440YC CDL7440TC CDL7463SC CDL7463YC CDL7463TC CDL7480SC CDL7480YC CDL7480TC CDL74100SC CDL74100YC CDL74100TC Final Distribution 2P 31 CDL7 Electromagnetic Type Residual Current Switch Standard: IEC 61008 RCCB Type: A , AC Sensitivity: 10, 30, 100, 300mA Technical Data RCCB Final Distribution Electrical Features Mechanical Features Connection CDL7 Electromagnetic Type Residual Current Switc h Standard IEC61008 Certification , KEMA、CB Type AC, A Poles 2P、4P , Rated Current In A 10,16,25,40,63,80,100P Rated Voltage Ue 230/400V AC Insulation Voltage Ui 500V Sensitivity 10,30,100,300mA Electrical Durability 1000 times Mechanical Durability 2000 times Overload or Short Circuit Protection no Tripping Indication Instantaneous, rated residual operated current unadjustable Fault Curren Indicator Mechanical indication in the front Protection Degree 2 Tropicalization Treatment 2 Ambient Temperature -25℃~+40℃ 2 Rate Installation Screw current(A) 25-100 Mounting Power source Auxilary Overall Dimensions 32 2 Up to 35mm cables(In>63A) Up to 16mm M5 Rated Torque Limiting Torque (Nm) (Nm) 2.0 4.5 35mm Din-rail Not need Accessory CDB6,CDB6LE The sketch map of installation with breakers Final Distribution SD OF Breaker MX+OF Remote Control Auxiliaries OF contact auxiliary SD fault-indicating switch Indicate ON or OFF state of the breaker Sent out fault signal on the font when breaking down Basic type of auxiliary contact:1NO+1NC Indicator on the front to show fault trip 2 Connection: 1-4mm cables Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables Tripping Device Introductions MX+OF shunt trip release OF, SD must be assembled on the left ,one auxiliary only Indicate ON or OFF state of the breaker Each time only one auxiliary accepted in the left of MCB Make the assembled breaker trip once got signal MX+OF must be assembled on the right, one MX+OF only Basic type of auxiliary contact:1NO+1NC CDB6LE can't assemble MX+OF Connection: 1-4mm2 cables Order Information type Width(mm) Voltage(V) Reference OF 9 CDB6OF SD 9 CDB6SD MX+OF 18 AC/DC 12V CDB6MX12 18 AC/DC 24V CDB6MX24 18 AC/DC 48V CDB6MX48 18 AC 110-130V CDB6MX110 18 AC 130V CDB6MX130 18 AC 230V CDB6MX230 18 AC 400V CDB6MX400 33 Accessory CDB6s The sketch map of installation with breakers Final Distribution SD CDB6s OF MX+OF Remote Control Auxiliaries OF contact auxiliary SD fault-indicating switch Indicate ON or OFF state of the breaker Sent out fault signal when breaking down Basic type of auxiliary contact:1NO+1NC Indicator on the front to show fault trip Connection:1-4mm2 cables Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables Tripping Device Introductions MX+OF shunt trip release OF,SD must be assembled on the left ,one auxiliary only Indicate ON or OFF state of the breaker Each time only one auxiliary accepted in the left of MCB Make the assembled breaker trip while given signal MX+OF must be assembled on the right, one MX+OF only Basic type of auxiliary contact:1NO+1NC CDB6s can't assemble MX+OF while assembled with CDB6v Connection:1-4mm2 cables Order Information 34 type Width(mm) Voltage(V) Reference OF 9 CDB6sOF SD 9 CDB6sSD MX+OF 118 AC/DC12-24V CDB6sMX24 18 AC/DC24-48V CDB6sMX48 18 AC110-127V CDB6sMX110 18 AC230-400V CDB6sMX230 Accessory CDB2,CDB2LE The sketch map of installation with breakers Final Distribution MX+OF Remote Control Auxiliaries OF contact auxiliary Indicate ON or OFF state of the breaker Basic type of auxiliary contact:2NO+2NC OF Breaker Introductions MX+OF, OF must be assembled on the left Each time only one auxiliary accepted in the left of MCB Connection: 1-4mm2 cables Tripping Device MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip once got signal Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables Order Information Type Width(mm) Description Reference OF 18 1NO 1NC CDB2OF11 18 2NO 2NC CDB2OF22 18 AC/DC24V CDB2MX24 18 AC48V~130V DC48V CDB2MX48 18 AC230V-400V DC110V-130V CDB2MX230 MX+OF 35 Accessory Busbar Technical Data Final Distribution Standard IEC 60664 Material of busbar E-CU-F25 Material of insulation PVC Short-circuit strength 50kA Nominal voltage 415V Operating voltage Max 500V Surge voltage 4kV Clima stability IEC 60068-2 Order Information Type Thickness Section Max. Pole of pin cross current(A) (mm) (mm2) End feed-in PIN-TYPE 1 2 3 4 U-TYPE 1 2 3 4 36 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 A Reference 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 CBB14012P CBB16315P CBB17015P CBB18015P CBB24012P CBB26315P CBB27015P CBB28015P CBB34012P CBB36315P CBB37015P CBB38015P CBB44012P CBB46315P CBB47015P CBB48015P CBB14012F CBB16315F CBB17015F CBB18015F CBB24012F CBB26315F CBB27015F CBB28015F CBB34012F CBB36315F CBB37015F CBB38015F CBB44012F CBB46315F CBB47015F CBB48015F Dimension(mm) A A A A A A A A CDCH8 Modular Contactor Standard: IEC 61095 Function CDCH8 Modular Contactor provide: Automatic control on equipment in buildings Switch on or Swith off lighting or other equipments Order Information Current (A) Voltage (V) Reference 2P 20 220V 230V 220V 230V CDCH8202M CDCH8202N CDCH8252M CDCH8252N 25 Final Distribution Pole Technical Data Building Control Command Devices CDCH8 Modular Contactor IEC 61095 Standard KEMA CE CB Certification Type AC-7a AC-7b 230V AC Rated Voltage Ue 500V AC Rated Insulation Voltage Ui Conventional Thermal Current(I ) Rated Current(le) Rated power Operation Frequency 20A/25A 20A/25A 9A/10A 4kw/5.4kw 1.2kw/1.4kw 1200times/h 30times/h ≥30000times Operation Time Making&Breaking capacity 1.5le 8le AC-7b,8le,10S With stand Overcurrent Capacity Adapted to fuse :RT18-32X/32 Short-circuit Protection Ambient Temperature Connection Adapted to breaker :CDB6s-63/C32 -5℃~+40℃ ~ Both 1 and 2 lines can be used CDCH8-20 1~2.5mm2, CDCH8-25,1~4mm2 Techenical Data of Coil Coil Voltage(Us) 220/230V AC Allowable Voltage of Controlloop(V) Operating:85%~110%Us Release:20%~75%Us Rated Power of Coil Start:16VA Holding:4VA Working power:1.4W 37 CDCH8 Modular Contactor Standard: IEC 61095 Wiring Diagram Final Distribution Overall Dimensions 38 CDRT8 Time Relay Standard:IEC 60947.5 Function CDRT8 Time Relay provide: Disconnect Delay Connect Delay Order Information Delay type Reference 10 power delay CDRT810B 120 power delay CDRT8120B 480 power delay CDRT8480B 480 off delay CDRT8480A Final Distribution Limit delay time Technical Data Building Control Command Devices CDRT8 Time Relay Standard IEC 60947.5 Rated Voltage Ue 230V AC Rated Current(le) 5A Delay Type Off dalay Power delay 10s 120s 480s Limit Delay Time th Conventional Thermal Current(l ) 8A Timing Range Contact Type Normally open contact Contact Number 1 Rated Control Supply Voltage(Us) 230V AC Operating Voltage Range 85%-110%Us Electrical Durability 30000 times Rated Wattage <1W Insulation Resistance > To each:AC 1760V 5s Insulation Strength Disconnect between the contact position:AC 1000V 1min Connection up to 1mm2 cables 39 CDRT8 Time Relay Standard:IEC 60947.5 Wiring Diagram Final Distribution Overall Dimensions 19max 68max 40 CDY1 Surge Protective Devices Standard: IEC61643 Function CDY1 surge protective devices provide: Applicable to household appliances and the like to offer protection When there is an over-voltage caused by either lightning strike or operation in the circuit Imax (kA) Imax Imax (kA) (kA) 20 40 60 80 100 Uc (V) Uc Uc (V) (V) Up (kV) Up Up (kV) (kV) Final Distribution Order Information Reference 1P Reference Reference 1P 1P 2P 3P 4P 1P+N 3P+N 2P 2P 3P 3P 4P 4P 1P+N 1P+N 3P+N 275 1.3 CDY1201275 CDY1202275 CDY1203275 CDY1204275 CDY1205275 CDY1206275 385 1.5 CDY1201385 CDY1202385 CDY1203385 CDY1204385 CDY1205385 CDY1206385 420 1.8 CDY1201420 CDY1202420 CDY1203420 CDY1204420 CDY1205420 CDY1206420 275 1.5 CDY1401275 CDY1402275 CDY1403275 CDY1404275 CDY1405275 CDY1406275 385 1.8 CDY1401385 CDY1402385 CDY1403385 CDY1404385 CDY1405385 CDY1406385 420 2.0 CDY1401420 CDY1402420 CDY1403420 CDY1404420 CDY1405420 CDY1406420 275 1.8 CDY1601275 CDY1602275 CDY1603275 CDY1604275 CDY1605275 CDY1606275 385 2.2 CDY1601385 CDY1602385 CDY1603385 CDY1604385 CDY1605385 CDY1606385 420 2.5 CDY1601420 CDY1602420 CDY1603420 CDY1604420 CDY1605420 CDY1606420 275 2.0 CDY1801275 CDY1802275 CDY1803275 CDY1804275 CDY1805275 CDY1806275 385 2.2 CDY1801385 CDY1802385 CDY1803385 CDY1804385 CDY1805385 CDY1806385 420 2.5 CDY1801420 CDY1802420 CDY1803420 CDY1804420 CDY1805420 CDY1806420 275 2.2 CDY11001275 CDY11002275 CDY11003275 CDY11004275 CDY11005275 CDY11006275 385 2.5 CDY11001385 CDY11002385 CDY11003385 CDY11004385 CDY11005385 CDY11006385 420 2.5 CDY11001420 CDY11002420 CDY11003420 CDY11004420 CDY11005420 CDY11006420 41 CDY1 Surge Protective Devices Standard: IEC61643 Technical Data Final Distribution Type Pole Nominal discharge current In(8/20us) kA Maximum discharge current Imax(8/20us) kA Maximum continuous operational voltage Uc V Protection level Up kV Leakage current (75%Uc 1mA) uA Response time ns Standard: IEC 61643 Certification: SEMKO, CB Overall Dimensions 42 CDY1-80 CDY1-100 1P, 1P+N, 2P, 3P, 3P+N, 4P 10 20 30 CDY1-20 CDY1-40 40 50 20 80 100 40 CDY1-60 60 275 385 420 275 385 420 275 385 420 275 385 420 275 385 420 1.3 ≤20 ≤25 1.5 1.8 1.5 1.8 2.0 1.8 2.2 2.5 2.0 2.2 2.5 2.2 2.5 2.5 CDPZ50 Series Lighting Distribution Box Standard: IEC60439-1 IEC60670 Function CDPZ50 series lighting distribution box provide: Protection against overload Protection against over voltage Protection against leakage Material Holistic steel-plastic Installation Surface installation Flush installation Material Full plastic (fire-retardancy) Installation Surface installation Flush installation Full plastic (Non fire-retardancy) Surface installation Flush installation No. of loop 6 Final Distribution Order Information Reference CDPZ50M6 8 CDPZ50M8 12 CDPZ50M12 16 CDPZ50M16 20 CDPZ50M20 24 6 CDPZ50M24 CDPZ50R6 8 CDPZ50R8 12 CDPZ50R12 16 CDPZ50R16 20 CDPZ50R20 24 No. of loop 4 6 8 12 15 18 24 36 4 6 8 12 15 18 24 36 4 6 8 12 15 18 24 36 4 6 8 12 15 18 24 36 CDPZ50R24 Reference CDPZ50PM4IP30F CDPZ50PM6IP30F CDPZ50PM8IP30F CDPZ50PM12IP30F CDPZ50PM15IP30F CDPZ50PM18IP30F CDPZ50PM24IP30F CDPZ50PM36IP30F CDPZ50PR4IP30F CDPZ50PR6IP30F CDPZ50PR8IP30F CDPZ50PR12IP30F CDPZ50PR15IP30F CDPZ50PR18IP30F CDPZ50PR24IP30F CDPZ50PR36IP30F CDPZ50PM4IP30NF CDPZ50PM6IP30NF CDPZ50PM8IP30NF CDPZ50PM12IP30NF CDPZ50PM15IP30NF CDPZ50PM18IP30NF CDPZ50PM24IP30NF CDPZ50PM36IP30NF CDPZ50PR4IP30NF CDPZ50PR6IP30NF CDPZ50PR8IP30NF CDPZ50PR12IP30NF CDPZ50PR15IP30NF CDPZ50PR18IP30NF CDPZ50PR24IP30NF CDPZ50PR36IP30NF 43 CDPZ50 Series Lighting Distribution Box Standard: IEC60439-1 IEC60670 Technical Data Final Distribution Type CDPZ50 CDPZ50P Material Box:Metal, Cover:Plastic Full Plastic Fire-resistancy Fire-resistancy Optional Protection grade IP30 Rated operation voltage 230/400V Rated insulated voltage 500V Rated operating current 100A Withstand current 6kA Overall Dimensions Unit:mm Surface installation Flush installation CDPZ50 Holistic steel-plastic Surface installation Flush installation Thickness Loop number 6 8 12 16 20 24 A 171 207 279 351 423 303 A 163 199 272 343 413 282 C 90 90 90 90 90 90 B 220 220 220 220 220 383 B 200 200 200 200 200 364 CDPZ50P Full plastic Loop number 4 6 8 12 15 18 24 36 44 Surface installation A 110 147 183 255 310 362 270 270 B 200 200 200 200 200 218 324 459 Flush installation Thickness A 126 162 198 270 324 378 261 261 C 90 90 90 90 90 90 90 90 B 200 200 200 200 200 216 310 441 JXF Power Distribution Box Standard: EN60529 Function JXF power distribution box provide: Control, monitering, measurement and protection for the electric power loops and main power controlling equipment. Order Information Overall Installation Mounting plate Final Distribution (mm) Lock Thick JXF-2520/14 IP43 JXF-3025/14 IP43 JXF-3025/18 IP43 JXF-3030/14 IP43 JXF-3030/18 IP43 JXF-4030/14 IP43 JXF-4030/20 IP43 JXF-5040/14 IP43 JXF-5040/20 IP43 JXF-5040/25 IP43 JXF-6040/14 IP43 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 250 300 300 300 300 400 400 500 500 500 600 200 250 250 300 300 300 300 400 400 400 400 140 140 180 140 180 140 200 140 200 250 140 290 340 340 340 340 440 440 540 540 540 150 200 200 250 250 250 250 350 350 350 170 220 220 220 220 320 320 420 420 420 158 208 208 258 258 258 258 358 358 358 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1 1 1 1 1 1 1 1 2 2 JXF252014 JXF302514 JXF302518 JXF303014 JXF303018 JXF403014 JXF403020 JXF504014 JXF504020 JXF504025 JXF-6040/20 IP43 JXF-6040/25 IP43 JXF-6050/14 IP43 JXF-6050/20 IP43 JXF-6050/25 IP43 JXF-7050/16 IP43 JXF-7050/20 IP43 JXF-7050/25 IP43 JXF-8060/20 IP43 JXF-8060/25 IP43 JXF-10080/20 IP43 JXF-10080/25 IP43 JXF-10080/30 IP43 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 600 600 600 600 600 700 700 700 800 800 1000 1000 1000 400 400 500 500 500 500 500 500 600 600 800 800 800 200 250 140 200 250 160 200 250 200 250 200 250 300 640 640 640 640 640 640 740 740 740 840 840 1040 1040 1040 350 350 350 450 450 450 450 450 450 550 550 750 750 750 520 520 520 520 520 520 620 620 620 720 720 920 920 920 358 358 358 458 458 458 458 458 458 558 558 758 758 758 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 2 2 2 2 2 2 2 2 2 2 2 2 JXF604014 JXF604020 JXF604025 JXF605014 JXF605020 JXF605025 JXF705016 JXF705020 JXF705025 JXF806020 JXF806025 JXF1008020 1.5 1.5 2 2 JXF1008025 JXF1008030 JXF-2520/14 IP43 Improved JXF-3025/14 IP43 Improved JXF-3025/18 IP43 Improved JXF-3030/14 IP43 Improved JXF-3030/18 IP43 Improved JXF-4030/14 IP43 Improved JXF-4030/20 IP43 Improved JXF-5040/14 IP43 Improved JXF-5040/20 IP43 Improved JXF-5040/25 IP43 Improved JXF-6040/14 IP43 Improved JXF-6040/20 IP43 Improved JXF-6040/25 IP43 Improved JXF-6050/14 IP43 Improved JXF-6050/20 IP43 Improved JXF-6050/25 IP43 Improved JXF-7050/16 IP43 Improved JXF-7050/20 IP43 Improved JXF-7050/25 IP43 Improved JXF-8060/20 IP43 Improved JXF-8060/25 IP43 Improved JXF-10080/20 IP43 Improved JXF-10080/25 IP43 Improved JXF-10080/30 IP43 Improved 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 250 300 300 300 300 400 400 500 500 500 600 600 600 600 600 600 700 700 700 800 800 1000 1000 1000 200 250 250 300 300 300 300 400 400 400 400 400 400 500 500 500 500 500 500 600 600 800 800 800 140 140 180 140 180 140 200 140 200 250 140 200 250 140 200 250 160 200 250 200 250 200 250 300 290 340 340 340 340 440 440 540 540 540 640 640 640 640 640 640 740 740 740 840 840 1040 1040 1040 150 200 200 250 250 250 250 350 350 350 350 350 350 450 450 450 450 450 450 550 550 750 750 750 170 220 220 220 220 320 320 420 420 420 520 520 520 520 520 520 620 620 620 720 720 920 920 920 158 208 208 258 258 258 258 358 358 358 358 358 358 458 458 458 458 458 458 558 558 758 758 758 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 JXF252014B JXF302514B JXF302518B JXF303014B JXF303018B JXF403014B JXF403020B JXF504014B JXF504020B JXF504025B JXF604014B JXF604020B JXF604025B JXF605014B JXF605020B JXF605025B JXF705016B JXF705020B JXF705025B JXF806020B JXF806025B JXF1008020B JXF1008025B JXF1008030B 45 JXF Power Distribution Box Standard: EN60529 Order Information Dimension(mm) Overall (mm) Installation Mounting plate Lock Thick Final Distribution JXF-2520/14 IP54 JXF-3025/14 IP54 JXF-3025/18 IP54 JXF-3030/14 IP54 JXF-3030/18 IP54 JXF-4030/14 IP54 JXF-4030/20 IP54 JXF-5040/14 IP54 JXF-5040/20 IP54 JXF-5040/25 IP54 JXF-6040/14 IP54 JXF-6040/20 IP54 JXF-6040/25 IP54 JXF-6050/14 IP54 JXF-6050/20 IP54 JXF-6050/25 IP54 JXF-7050/16 IP54 JXF-7050/20 IP54 JXF-7050/25 IP54 JXF-8060/20 IP54 JXF-8060/25 IP54 JXF-10080/20 IP54 JXF-10080/25 IP54 JXF-10080/30 IP54 46 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 250 300 300 300 300 400 400 500 500 500 600 600 600 600 600 600 700 700 700 800 800 1000 1000 1000 200 250 250 300 300 300 300 400 400 400 400 400 400 500 500 500 500 500 500 600 600 800 800 800 140 140 180 140 180 140 200 140 200 250 140 200 250 140 200 250 160 200 250 200 250 200 250 300 320 370 370 370 370 470 470 570 570 570 670 670 670 670 670 670 770 770 770 870 870 1070 1070 1070 150 200 200 250 250 250 250 350 350 350 350 350 350 450 450 450 450 450 450 550 550 750 750 750 215 265 265 265 265 365 365 465 465 465 565 565 565 565 565 565 665 665 665 765 765 965 965 965 148 198 198 248 248 248 248 348 348 348 348 348 348 448 448 448 448 448 448 548 548 748 748 748 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1 1 1 1 1 1 1 2 2 JXF252014Q JXF302514Q JXF302518Q JXF303014Q JXF303018Q JXF403014Q JXF403020Q JXF504014Q JXF504020Q 2 2 2 2 2 2 2 2 2 2 JXF504025Q JXF604014Q JXF604020Q JXF604025Q JXF605014Q JXF605020Q JXF605025Q JXF705016Q JXF705020Q JXF705025Q 2 2 2 2 2 JXF806020Q JXF806025Q JXF1008020Q JXF1008025Q JXF1008030Q JXF Power Distribution Box Standard: EN60529 Technical Data JXF IP43 JXF IP43 Improved JXF IP54 Protection grade IP43 IP43 IP54 Standard: EN60529 Certificate CE Rated voltage 220/400V Rated insulated voltage 660V Rated operating current 400A Withstand current 15kA Sheet thickness 1.0~1.5mm 1.0~1.5mm 1.2~1.5mm Mounting plate thickness 1.0~1.5mm 1.0~1.5mm 2.0mm Hinge Normal Enhanced Enhanced Sealing rubber gasket Seal band Black rubber gasket Black rubber gasket Cable gland Top and bottom bottom only bottom only Final Distribution Type Overall Dimensions Unit: mm sealing rubber gasket sealing rubber gasket handle lock door wall fixing bracket box hinge 47 Contents Low-voltage Distribution Low-voltage Distribution 48 Molded Case Circuit Breaker 49-63 CDM1 Molded Case Circuit Breaker 49 CDMLE Earth-Leakage Circuit Breaker 57 Air Circuit Breaker 64-82 CDW7 64 Air Circuit Breaker CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 Function CDM1 moulded case circuit breaker provide: To distribute electric power To protect power line and equipments against overload, undervoltage and shortcircuit faults (In≤400A) To infrequently start and control AC motors Order Information Type CDM1-63 In A 3P 2P 3P 4P 49 Low-voltage CDM1-100 40 50 63 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 Type L CDM163L103 CDM163L163 CDM163L203 CDM163L253 CDM163L323 CDM163L403 CDM163L503 CDM163L633 -----------------CDM1100L163 CDM1100L203 CDM1100L253 CDM1100L323 CDM1100L403 CDM1100L503 CDM1100L633 CDM1100L803 CDM1100L1003 ---------- Distribution 4P 10 16 20 25 32 Reference Type M CDM163M103 CDM163M163 CDM163M203 CDM163M253 CDM163M323 CDM163M403 CDM163M503 CDM163M633 CDM163M104 CDM163M164 CDM163M204 CDM163M254 CDM163M324 CDM163M404 CDM163M504 CDM163M634 CDM1100M162 CDM1100M202 CDM1100M252 CDM1100M322 CDM1100M402 CDM1100M502 CDM1100M632 CDM1100M802 CDM1100M1002 CDM1100M163 CDM1100M203 CDM1100M253 CDM1100M323 CDM1100M403 CDM1100M503 CDM1100M633 CDM1100M803 CDM1100M1003 CDM1100M164 CDM1100M204 CDM1100M254 CDM1100M324 CDM1100M404 CDM1100M504 CDM1100M634 CDM1100M804 CDM1100M1004 CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 Order Information Type CDM1-225 In A 2P 3P Low-voltage Distribution 4P CDM1-400 3P 4P CDM1-630 3P 4P CDM1-800 3P 4P CDM1-1250 3P 100 125 160 180 200 225 100 125 160 180 200 225 100 125 160 180 200 225 200 225 250 315 350 400 200 215 250 315 350 400 400 500 630 400 500 630 400 500 630 700 800 400 500 630 700 800 700 800 1000 1250 Reference Type L Type M CDM1225M1002 -CDM1225M1252 -CDM1225M1602 -CDM1225M1802 --CDM1225M2002 -CDM1225M2252 CDM1225L1003 CDM1225M1003 CDM1225L1253 CDM1225M1253 CDM1225L1603 CDM1225M1603 CDM1225L1803 CDM1225M1803 CDM1225L2003 CDM1225M2003 CDM1225L2253 CDM1225M2253 -CDM1225M1004 -CDM1225M1254 -CDM1225M1604 -CDM1225M1804 -CDM1225M2004 -CDM1225M2254 CDM1400L2003 CDM1400M2003 CDM1400L2253 CDM1400M2253 CDM1400L2503 CDM1400M2503 CDM1400L3153 CDM1400M3153 CDM1400L3503 CDM1400M3503 CDM1400L4003 CDM1400M4003 CDM1400M2004 -CDM1400M2254 -CDM1400M2504 --CDM1400M3154 -CDM1400M3504 -CDM1400M4004 CDM1630L4003 CDM1630M4003 CDM1630L5003 CDM1630M5003 CDM1630L6303 CDM1630M6303 -CDM1630M4004 -CDM1630M5004 -CDM1630M6304 CDM1800L4003 CDM1800M4003 CDM1800L5003 CDM1800M5003 CDM1800L6303 CDM1800M6303 CDM1800L7003 CDM1800M7003 CDM1800L8003 CDM1800M8003 -CDM1800M4004 -CDM1800M5004 -CDM1800M6304 -CDM1800M7004 -CDM1800M8004 -CDM11250M7003 -CDM11250M8003 -CDM11250M10003 -CDM11250M12503 Note: The connection mode for CDM1 is the fixed type front connection. 50 CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 Order Information for Assessories Voltage (V) Type 230V AC 400V AC CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 OF CDM163OF* SD CDM163SD* TR(Round Handle) TS(Square Handle) CDM163TR CDM163TS CDM1100OF* CDM1100SD* CDM1100TR CDM1100TS CDM1225OF* CDM1225SD* CDM1225TR CDM1225TS CDM1400OF* CDM1400SD* CDM1400TR CDM1400TS CDM1630OF* CDM1630SD* CDM1630TR CDM1630TS CDM1800OF* CDM1800SD* CDM1800TR CDM1800TS CDM11250OF* Note 1: MN and MX could be sold with CDM1 product and installed by manufactory 2: *means the connecting type; Blank: terminal connection; D5: 500mm wire connection 9 8 10 7 11 1 2 12 6 5 4 13 3 1 Connection 6 Shunt release contactor 11 Stationary type rear connection R 2 Phase partition 7 Undervoltage release contactor 12 Alarm contactor 3 Motor mechanism 8 Plug-type connection terminal 13 Auxiliary contactor 4 Round handle mechanism 9 Plug-type front connection 5 Quadrate handle mechanism 10 Plug-type rear connection 51 Low-voltage CDM1-1250 MX CDM163MX230* CDM163MX400* CDM1100MX230* CDM1100MX400* CDM1225MX230* CDM1225MX400* CDM1400MX230* CDM1400MX400* CDM1630MX230* CDM1630MX400* CDM1800MX230* CDM1800MX400* CDM11250MX230* CDM11250MX400* Distribution CDM1-800 Reference MN CDM163MN230* CDM163MN400* CDM1100MN230* CDM1100MN400* CDM1225MN230* CDM1225MN400* CDM1400MN230* CDM1400MN400* CDM1630MN230* CDM1630MN400* CDM1800MN230* CDM1800MN400* CDM11250MN230* CDM11250MN400* CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 Technical Data Main technical parameters are shown in the table below MCCB CDM1 standard IEC 60947-2 MCCB KEMA,SEMKO,CB,CE Type CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250 63 100 225 400 630 800 1250 Frame size rated current A Number of poles Rated frequency Hz Rated current In A Low-voltage Distribution Rated insulation voltage Ui V Rated impulse withstand voltage Uimp V Rated operational voltage Ue V Icu kA Type M (400V) Type L Ics kA Type M (400V) Type L 3P,4P 50/60 10 16 20 25 32 40 50 63 2P,3P,4P 3P,4P 3P 400 500 700 800 630 700 1000 800 1250 690 16 20 100 125 200 350 400 500 25 30 160 180 250 315 630 32 40 200 225 400 50 63 80 100 800 690/750 6000 8000 6000/8000 6000 400 400 / 690 400 400 690 65 45 42 34 400 70 50 40 30 85 45 - 60 1000 4000 20 500 2500 20 500 2500 150 200 135 190 240 300 50 25 30 18 Arcing distance mm 50 Durability Cycles/h 120 Electrical 4000 Mechanical 6000 Power consumpution (W) Fixed 25 Plug-in 30 50 35 30 26 50 35 30 26 120 1500 8500 120 1000 7000 70 50 40 30 100 60 1000 4000 40 50 60 75 40 110 690 Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The circuit breaker can be fixed type or plug-in type For 4-pole circuit breakers: N-pole without overcurrent release, it switches on and off with other poles ( N-pole lead-make, lag-break) Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part 52 CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 Accessories The accessories are fixed into the circuit breaker. ■ Remote tripping: MX or MN releases are used to trip the circuit breaker. ■ This release trips the circuit breaker when the control voltage drops below the tripping threshold: □ Tripping threshold between 35% to 70% of the rated voltage □ Circuit-breaker closing is possible only if the voltage exceeds 85% of the rated voltage. ■ Circuit-breaker tripping by an MN release meets the requirements of standard IEC 60947-2. power source input MN (Undervoltage Release) ■ □ □ 230V, 400V AC (0.35~0.7) Ue (0.85~1.1) Ue MX shunt release: The MX release trips the circuit breaker when the control voltage rises above 0.7 x Un. Control signals can be of the impulse type (u 20 ms) or maintained. MX (Shunt Release) Technical data power source input Rated control voltage US(V) Operating voltage(V) ■ □ □ ■ □ □ 230V, 400V AC (0.7~1.1) US Indication contacts: These common-point changeover contacts can be used to remotely indicate circuit-breaker status information for indications, electrical locking, relays, etc. They comply with international standard IEC 60947-5. Functions: OF (ON/OFF): indicates the position of the circuit-breaker contacts. SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload v short-circuit v operation of a voltage release v operation of the“push-to-trip” button Returns to de-energised state when the circuit breaker is reset. OF (Auxiliary Contactor) Auxiliary Contact wiring diagram Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC (Change over) 2NO+2NC (Change over) 0.4A (400V AC) SD (Alarm Contactor) “Trip” position Arm Switch wiring diagram Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC 0.26A (400V AC) 0.4A (400V AC) 53 Low-voltage Rated operating voltage Ue(V) Drop-out voltage(V) Pick-up voltage(V) Distribution Technical data CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 Overall Dimensions Low-voltage Distribution Type Poles Overall Dimensions L L1 W H H1 H2 a b Φd CDM1-63L 3 135 21 76 89 74 21 25 117 3.5 CDM1-63M 3 135 21 76 99 82 28 25 117 3.5 CDM1-63M 4 135 21 103 99 82 28 25 117 3.5 CDM1-100M 2 150 51 65 103 87 24 -- 129 4.5 CDM1-100L 3 150 51 92 87 68 25 30 129 4.5 CDM1-100M 3 150 51 92 103 87 24 30 129 4.5 CDM1-100M 4 150 51 122 103 87 24 30 129 4.5 CDM1-225M 2 165 64 75 124 104 24 -- 126 5.5 CDM1-225L 3 165 64 107 108 87 24 35 126 5.5 CDM1-225M 3 165 64 107 124 104 24 35 126 5.5 CDM1-225M 4 165 64 142 124 104 24 35 126 5.5 CDM1-400L,M 3 257 105 140 146 100 36 44 215 6.5 CDM1-400M 4 257 105 184 146 100 36 44 215 6.5 CDM1-630L,M 3 270 118 182 160 108 41 58 200 7 CDM1-630M 4 270 118 240 160 108 41 58 200 7 CDM1-800L,M 3 280 102 210 146 103 34 70 243 7 CDM1-800M 4 280 102 280 146 103 34 70 243 7 CDM1-1250M 3 406 104 210 190 140.5 58 70 375 10 Install dimensions Unit:mm 2P ■ 3P 4P e Overall and cut-out diagram of round handle hinge 54 CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 ■ Overall and cut-out diagram of square handle hinge ■ Centrally revolvable type Unit:mm ■ H 49 54 54 76 83 76 Eccentrically rotating Unit:mm Dimension for handle mechanism(eccentrically revolvable type) Frame CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 A 35 35 65 60 48 B 11.5 31 15 15 15 H 46 48 61 61 66 55 Low-voltage Distribution Dimension for handle mechanism(centrally revolvable type) A B Frame 117 25 CDM1-63 129 30 CDM1-100 126 35 CDM1-225 215 44 CDM1-400 200 58 CDM1-630 243 70 CDM1-800 CDM1 Moulded Case Circuit Breaker Standard: IEC 60947-2 Characteristic Curve of Circuit Breaker max max max min min min Instantaneous current Low-voltage Distribution Delay trip Instantaneous current Delay trip Instantaneous trip For power distribution CDM1-63 Time / current characteristic curve Delay trip Instantaneous trip For power distribution CDM1-100 Time / current characteristic curve max max min min Delay trip Delay trip Instantaneous trip Instantaneous trip For power distribution Delay trip Delay trip Instantaneous trip Instantaneous trip For power distribution CDM1-400 Time / current characteristic curve CDM1-630 Time / current characteristic curve 56 Delay trip Instantaneous trip Instantaneous trip For power distribution CDM1-225 Time / current characteristic curve CDM1LE Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Function Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The residual operating current value can be fixed or adjustable The residual operating current protection can be with time-delay or without time-delay Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the position indication contact, for detail see the accessories part Product name Frame current Breaking capacity Current Pole CD M1LE 100 M 16 3 100:100A 225:225A 400:400A L: L type M: M type 16: 16A … 400: 400A 3:3 pole 4:4 pole Usage Blank for distribution protection Residual current N Pole L A S:30mA Y:100mA T:300mA F:500mA KY:30/100/500mA KT:100/300/500mA For CDM1LE 4pole: A=A type (Direct connect) B=B type (Direct connect, lead-make, lag break) 57 Low-voltage Country code Distribution Coding System CDM1LE Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Order Information Type CDM1LE-100 3P Low-voltage Distribution 4P A 4P B CDM1LE-225 3P 4P A 4P B Note:* express residual current. 58 Rated current In A 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 100 125 140 160 180 200 225 100 125 140 160 180 200 225 100 125 140 160 180 200 225 Reference Type M CDM1LE100M163* CDM1LE100M203* CDM1LE100M253* CDM1LE100M323* CDM1LE100M403* CDM1LE100M503* CDM1LE100M633* CDM1LE100M803* CDM1LE100M1003* CDM1LE100M164*A CDM1LE100M204*A CDM1LE100M254*A CDM1LE100M324*A CDM1LE100M404*A CDM1LE100M504*A CDM1LE100M634*A CDM1LE100M804*A CDM1LE100M1004*A CDM1LE100M164*B CDM1LE100M204*B CDM1LE100M254*B CDM1LE100M324*B CDM1LE100M404*B CDM1LE100M504*B CDM1LE100M634*B CDM1LE100M804*B CDM1LE100M1004*B CDM1LE225M1003* CDM1LE225M1253* CDM1LE225M1403* CDM1LE225M1603* CDM1LE225M1803* CDM1LE225M2003* CDM1LE225M2253* CDM1LE225M1004*A CDM1LE225M1254*A CDM1LE225M1404*A CDM1LE225M1604*A CDM1LE225M1804*A CDM1LE225M2004*A CDM1LE225M2254*A CDM1LE225M1004*B CDM1LE225M1254*B CDM1LE225M1404*B CDM1LE225M1604*B CDM1LE225M1804*B CDM1LE225M2004*B CDM1LE225M2254*B Type L CDM1LE100L163* CDM1LE100L203* CDM1LE100L253* CDM1LE100L323* CDM1LE100L403* CDM1LE100L503* CDM1LE100L633* CDM1LE100L803* CDM1LE100L1003* CDM1LE100L164*A CDM1LE100L204*A CDM1LE100L254*A CDM1LE100L324*A CDM1LE100L404*A CDM1LE100L504*A CDM1LE100L634*A CDM1LE100L804*A CDM1LE100L1004*A CDM1LE100L164*B CDM1LE100L204*B CDM1LE100L254*B CDM1LE100L324*B CDM1LE100L404*B CDM1LE100L504*B CDM1LE100L634*B CDM1LE100L804*B CDM1LE100L1004*B CDM1LE225L1003* CDM1LE225L1253* CDM1LE225L1403* CDM1LE225L1603* CDM1LE225L1803* CDM1LE225L2003* CDM1LE225L2253* CDM1LE225L1004*A CDM1LE225L1254*A CDM1LE225L1404*A CDM1LE225L1604*A CDM1LE225L1804*A CDM1LE225L2004*A CDM1LE225L2254*A CDM1LE225L1004*B CDM1LE225L1254*B CDM1LE225L1404*B CDM1LE225L1604*B CDM1LE225L1804*B CDM1LE225L2004*B CDM1LE225L2254*B CDM1LE Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Order Information Type CDM1LE-400 3P 4P A Type L CDM1LE400M2003* CDM1LE400M2503* CDM1LE400M3153* CDM1LE400M3503* CDM1LE400M4003* CDM1LE400L2003* CDM1LE400L2503* CDM1LE400L3153* CDM1LE400L3503* CDM1LE400L4003* 200 CDM1LE400M2004*A CDM1LE400L2004*A 225 CDM1LE400M2254*A CDM1LE400L2254*A 250 CDM1LE400M2504*A CDM1LE400L2504*A 315 CDM1LE400M3154*A CDM1LE400L3154*A 350 CDM1LE400M3504*A CDM1LE400L3504*A 400 CDM1LE400M4004*A CDM1LE400L4004*A 200 CDM1LE400M2004*B CDM1LE400L2004*B 225 CDM1LE400M2254*B CDM1LE400L2254*B 250 CDM1LE400M2504*B CDM1LE400L2504*B 315 CDM1LE400M3154*B CDM1LE400L3154*B 350 CDM1LE400M3504*B CDM1LE400L3504*B 400 CDM1LE400M4004*B CDM1LE400L4004*B Note:* express residual current. Order Information for Accessories Voltage (V) Type Reference MN* 230V AC 400V AC CDM1LE-100 CDM1LE100MN230* CDM1LE100MN400* CDM1LE-225 CDM1LE225MN230* CDM1LE225MN400* CDM1LE-400 CDM1LE400MN230* MX* OF SD TS(Square Handle) CDM1LE100MX230* CDM1LE100OF* CDM1LE100SD* CDM1LE100TS CDM1LE100MX400* CDM1LE225MX230* CDM1LE225OF* CDM1LE225SD* CDM1LE225TS CDM1LE225MX400* CDM1LE400MX230* CDM1LE400OF* CDM1LE400SD* CDM1LE400TS TR(Round Handle) CDM1LE100TR CDM1LE225TR CDM1LE400TR CDM1LE400MN400* CDM1LE400MX400* Note 1: MN and MX could be sold with CDM1LE product and installed by manufactory 2: *means the connecting type; Blank: terminal connection; D5: 500mm wire connection 59 Low-voltage Type M 200 250 315 350 400 Distribution 4P B Reference Rated current In A CDM1LE Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Technical Data Type CDM1LE-100 CDM1LE-225 CDM1LE-400 Frame size rated current A 100 225 400 Rated current In A 16 20 25 32 40 100 125 140 160 200 250 315 50 63 80 100 180 200 225 350 400 Rated frequency Hz 50/60 Rated insulation voltage Ui V 800 Rated operational voltage Ue V 400 Rated impulse withstand voltage Uimp V 8000 Number of poles 3P, 4P Low-voltage Distribution Icu kA Type M 50 50 _ (400V) Type L 35 35 50 Ics kA Type M 35 35 _ (400V) Type L 22 22 30 Rated residual Without delay 30/100/500 30/100/500 100/300/500 100/300/500 100/300/500 100/300/500 100/300/500 100/300/500 1/2 IΔn 1/2 IΔn 1/2 IΔn Electrical 1500 1000 1000 Mechanical 8500 7000 4000 Total 10000 8000 5000 operating current IΔn (mA) With delay Rated residual non-operating current IΔn(mA) Durability Maximum break time for residual operating current protection Number of poles IΔn 2 IΔn 5 IΔn 10 IΔn Max. break Without delay 0.2 0.1 0.04 0.04 time S With delay 0.5/1.15/2.15 0.35/1/2 0.25/0.9/1.9 0.25/0.9/1.9 Table for 4 pole CDM1LE (Neutral line) Code Note A N(direct connect) B N(direct connect N pole lead-make, lag-break) Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The residual operating current value can be fixed fxed or or adjusted adjusted The residual operating current protection can be with time-delay or without time-delay Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part 60 CDM1LE Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Handle mechanism ■ Centrally revolvable type Unit:mm ■ Square Handle CDM1LE-100 CDM1LE-225 CDM1LE-400 Dimension 49 55 74 Accessories The accessories are fixed into the circuit breaker. ■ Remote tripping: MX or MN releases are used to trip the circuit breaker. ■ This release trips the circuit breaker when the control voltage drops below the trip ping threshold: □ tripping threshold between 0.35 and 0.7 times the rated voltage □ circuit-breaker closing is possible only if the voltage exceeds 0.85 times the rated voltage. ■ Circuit-breaker tripping by an MN release meets the requirements of standard IEC 60947-2. MN (Undervoltage Release) Technical data Power source input Rated operating voltage Ue(V) Drop-out voltage(V) Pick-up voltage(V) 230V, 400V AC (0.35~0.7) Ue (0.85~1.1) Ue 61 Low-voltage Distribution Dimension for handle mechanism Frame CDM1LE Earth-Leakage Circuit Breaker Standard: IEC 60947-2 ■ □ □ MX shunt release: The MX release trips the circuit breaker when the control voltage rises above 0.7 x Un. Control signals can be of the impulse type (u 20 ms) or maintained. MX (Shunt Release) Technical data Rated control voltage Us(V) Operating voltage(V) ■ □ Power source input □ Low-voltage Distribution ■ □ □ 230V, 400V AC (0.7~1.1) Us Indication contacts: These common-point changeover contacts can be used to remotely indicate circuit-breaker status information for indications, electrical locking, relays, etc. They comply with international standard IEC 60947-5. Functions: OF (ON/OFF): indicates the position of the circuit-breaker contacts. SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload v short-circuit v operation of a voltage release v operation of the“push-to-trip” button Returns to de-energised state when the circuit breaker is reset. OF (Auxiliary Contactor) Auxiliary Contact wiring diagram Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC (Change over) 2NO+2NC (Change over) 0.4A (400V AC) SD (Alarm Contactor) “Trip” position Arm Switch wiring diagram Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC 62 0.26A (400V AC) 0.4A (400V AC) CDM1LE Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Overall Dimensions Unit:mm Type Poles Overall size L1 CDM1LE-100L 3 92max 4 122max CDM1LE-100M 3 92max 4 122max CDM1LE-225L 3 107max 4 142max CDM1LE-225M 3 107max 4 142max CDM1LE-400L,M 3 150max 4 198max L2 150max 150max 150max 150max 165max 165max 165max 165max 257max 257max L3 94max 94max 110max 110max 94max 94max 110max 110max 150max 150max L4 75max 75max 92max 92max 72max 72max 90max 90max 107max 107max Installation size a b Φd 30 129 4×Φ4.5 60 129 6×Φ4.5 30 129 4×Φ4.5 60 129 6×Φ4.5 35 126 4×Φ4.5 70 126 6×Φ4.5 35 126 4×Φ4.5 70 126 6×Φ4.5 48 194 4×Φ4.5 95 194 6×Φ6.5 63 Low-voltage Distribution Key to Overall Dimensions CDW7 Air Circuit Breaker Standard: IEC 60947-2 Application Applied to power distribution of AC 50Hz/60Hz, rated operational voltage 400/690V, rated current 200A~6300A and lower For power distribution and protecting circuit and power supply equipment aganist harm from overload, undervoltage, short circuit, earthing, and other faults Circuit breaker which ampere frame size is under 630A can protect motor aganist overload,undervoltage and shortcircuit Core parts use intelligent control unit which has accurate discrimination protection, it can avoid unnecessary power failure and enhance the reliability of power supply system Standard and Certification Low-voltage Distribution Standard: IEC60947-2 Approved certification: CB, CE, KEMA Operating condition and installation recommendation Ambiant temperature Altitude Environmental humidity Degree of pollution Installation position Category of installation 64 Ambient temperature shall be controlled between +40℃ and -5℃, the average temperature in 24 hours shall not exceed +35℃ Note:contacting manufacturer about circuit breaker used in place where ambient temperature is higher than +40℃ or lower than -5℃ Altitude of installation position shall not exceed than 2000m The relative humidity of the installation position shall not exceed 50% when the maximum temperature reached +40℃, but there can be higher relative humidity under lower temperature, for example, i t c a n r e a c h 9 0 % a t 2 0℃. C o n s i d e r i n g t h a t condensation occurred on product surface when temperature changes Ⅲ Vertically mounting, tolerance on slope in any direction shall not exceed 5° Main circuit and undervoltage trip coil, power transformer primary coil:Ⅵ Auxiliary circuit,control circuit:Ⅲ CDW7 Air Circuit Breaker Standard: IEC 60947-2 Parameter and characteristics Certification approved: IEC 60947-1 IEC 60947-2 Type CDW7-1000 CDW7-2000 CDW7-3200 CDW7-6300 Number of poles 3, 4 3, 4 3, 4 3, 4 Utilization categories B B B B Arc-over distance (mm) 0 0 0 0 400 400/690 400/690 400 Ui 690 800 800 800 Rated impulse withstand voltage (V) Uimp 8000 8000 8000 8000 50 50 50 50 200/400/630 630/800/1000 2000/2500 4000/5000 /800/1000 /1250/1600/2000 /3200 /6300 AC 400V 42 65 80 120 AC 690V -- 50 65 -- AC 400V 30 50 80 100 AC 690V -- 40 50 -- AC 400V 88 176 220 264 AC 690V -- 105 143 -- AC 400V 30 40 50 85 AC 690V -- 40 50 -- mechanical 9000 9000 4500 1500 electrical 1000 1000 500 500 Rated frequency (Hz) Rated current (A) In Rated ultimate short circuit breaking capacity (kA) Icu Rated service short circuit breaking capacity (kA) Rated short circuit making capacity (kA) Rated short circuit withstand current (kA) Service life(c/o cycles) Ics Icm Icw 65 Low-voltage Ue Rated insulation voltage (V) Distribution Rated opertional voltage (V) CDW7 Air Circuit Breaker Standard: IEC 60947-2 Protection characteristics structural feature of ESW series intelligent controller Interlocking device Floor plate Contactor Device Chassis Controller Accessories Reset devise Magnetic flux converter Basic circuit Chassis and other units Sensor Mutual inductor Power supply accessories AC power supply DC power supply UPS Relay Low-voltage Distribution Outline and operation of ECW series intelligent controller ECWS-H (Applicable to CDW7-1000) ELECTRIC ECWS-H 1 2 ECWS-H 3 Ir1 RESET 4 Warn/ Alarm Healthy Ir2 Bus 5 Isd Ir4 Ir3 6 SEPECIFICATION 1-LCD interface display 2-Fault and alarm reset button 3-“Fault/Alarm” LED In normal state, this LED is off. In case of fault release, the red LED will flash quickly; in case of alarm, the red LED will be on constantly 4-“Normal” LED As long as the controller is on and operates normally, the green LED always flashes 5-Communication indicator The communication state indication is as follows: Profibus: OFF if no communication; ON if communication exists Modbus: OFF if no communication; flash if communication exists Device Net: Flash if no communication; ON if communication exists 6-Curve LEDs Red LEDs exist behind the curve. In case of fault release, the corresponding LED will flash indicating the fault type; During the parameter setting process, the LED is always on and indicates the current item. Keypad 66 7 8 9 10 11 12 13 14 7-Measure key l, used to switch to the default measurement menu. 8-Set key 2, used to switch to the parameter setting menu. 9-Protection Key 3, used to switch to the protection parameter setting menu. 10-Info key 4, used to switch to the historical record and maintenance menu. 11-Up, Move up the cursor through the menu items on the current level, or increment the value of the selected parameter. 12-Down, Move down the cursor through the menu items on the current level, or decrement the value of the selected parameter. 13-Exit, exit from the current level and return to the upper level, or cancel the current parameter selection. 14-Select, Select to enter into the next level from the current item, or select the current parameter, or store the change. CDW7 Air Circuit Breaker Standard: IEC 60947-2 ECW-M(applicable to CDW72000/3200/6300) 1 ECW-M 2 3 4 5 8 67 Low-voltage 7 1-Reset button of Fault release In case of breakers tripping, breakers cant be reclosed until this button is pressed. 2-voltmeter display Display the phase current ,normally display the Max.phase current. 3-light—emitting diode Indicators Display Setting , test , fault and Categorization 4-Ammeter display Display each of the phase current value and earth or leakage current value. Normally display Max. phase current value and can display the value of setting , test and fault current or time . 5-Key button Setting , test, check various state and Categorization 6-“lighting clear ”or “reset ”button When it is pressed ,the controller enters into normal run state , The breaker cant be closed until the button is pressed in case of setting, test, fault. 7-Shaft hole for test current 8-Shield As soon as the controller enters into normal run state ,the shield need to be sealed to protect the setting parameter. Distribution 6 SEPECIFICATION CDW7 Air Circuit Breaker Standard: IEC 60947-2 ECW-H (enhanced type ,applicable to CDW7 2000/3200/6300) SPECIFICATION ELECTRIC 1 ECW-H 2 3 4 Low-voltage Distribution Ir1 RESET 5 Warn/ Alarm Healthy Ir2 Bus 6 Isd Ir4 Ir3 7 1-Mechanical reset button(the button will pop up when fault tripping or test tripping, circuit breaker won’t be closed without pressing down,when the button is pressed down,fault indication is reset immediately) 2-LCD display screen 3-Warn and alarm reset 4-Warn/ alarm LED When normally operated, LED is off When fault tripping , red LED will blink quickly When alarming, red LED is opening eternally 5-“Healthy” LED:green LED will blink continuously as long as the controller is energized and operating healthily 6-Communication lamp Communication status is indicated as follows Profibus:off when without communication,on uninterrupted when in communication Modbus:off when without communication,blinking when in communication Device Net:blinking when without communication,on uninterrupted when in communication 7-Curve LED A red LED lamp is hided in curve When triped by failure , the regarding LED will blink to indicate the failure type, when the protection reference is set, the lighting LED will indicate the set option 8-There is a 16pin test connector in the bottom of front plate of test terminal,you can insert a plug-in portable power box and inspection -unit Keypad 8 TEST 68 9 10 11 12 13 14 15 16 9-Measurement function key1, navigated to measurement default theme menu 10-Setting function key2, navigated to parameter setting theme menu 11-Protection function key3, navigated to protection parameter setting theme menu 12-Information function key4, navigated to history and maintenance theme menu 13-Move upwards from the current used level to change the menu content,or change the selected parameter 14-Move downwards from the current used level to change the menu content,or change the selected parameter 15-Exit the current used level to back the parent menu,or cancel the current parameter 16-Choose to enter the currrent programme leading to son menu,or select the current parameter, store the modification CDW7 Air Circuit Breaker Standard: IEC 60947-2 ECW series intelligent controller function feature Intelligent controller function ECWS- H Basic function Addtional function* Protection Different curves available Measurement Maintenance Human-machine Digital Four phase current (I1, Up to 8 fault logs LCD display of MCR and out-of-limit for long time delay I2, I 3, IN) and earth Up to 8 alarm logs Chinese GUI tripping protection protection current Up to 8 position logs LED indication DO Signal alarm function Different curves available Thermal capacity Historical current peak Key operation Communication function Contact equivalence for inverse short time Number of operating delay protection cycles Definite short time delay Clock function protection Self-diagnosis function Instantaneous protection phase) protection Earth protection Earth fault alarm Neutral phase protection Load monitor ECW - M Long time delay protection Max. phase current Fault log Digital display DO Signal alarm function Definite time delay + Four phase current (I1, Self-diagnosis LED indication MCR and out-of-limit I2, I 3, IN) and earth function Key operation tripping protection current Feature test function Digital setting of Earth fault or leakage protection parameters protection (either) inverse time delay for short time delay protection Instantaneous protection Earthing protection Load monitor Different curves available ECW - H for long time delay Four phase current (I1, Up to 8 fault logs LCD display of Chinese Over-voltage protection protection I2, I 3, IN) and earth Up to 8 alarm logs GUI Under-voltage protection current Up to 8 position logs LED indication Voltage unbalance Thermal capacity Historical current Key operation protection Different curves available for inverse short time delay protection Definite short time delay protection Instantaneous protection MCR and out-of-limit tripping protection Current unbalance (open peak Over-currency protection Contact equivalence Under-frequency Number of operating protection cycles Phase protection Fault clock function Inverse power protection Self-diagnosis fault Demand protection log Zonal system interlock Self-diagnosis protection phase) protection function Communication function Earth protection Feature test function Earth fault alarm Neutral phase protection Load monitor note:* can measure voltage,frenquency,voltage unbalance rate,phase-sequency detection, power,energy,demand paramteter(current,power),harmonic 69 Low-voltage Distribution Current unbalance (open CDW7 Air Circuit Breaker Standard: IEC 60947-2 Basic protection Long time CDW7-1000 CDW7-2000~6300 Basic configuration ECWS-H intelligent ECW-M intelligent controllers ECW-H intelligent controllers of ECW intelligent controller controllers Current Setting Ir1=(0.4~1)ln Ir1=(0.4~1)ln Ir1=(0.4~1)ln Action conventional non-tripping 1.05×Ir1 h characteristics conventional tripping ≥2h ≥2h ≥2h 1.3×Ir1 h ≤2h ≤1h ≤1h 1.5Ir1 8,12.8,19.2,32,48,64,80,108 15,30,60,120,240,480 15,30,60,120,240,360,480,60 ,144,224,320,480,640,800,9 0,720,840,960 60,1120 2.0Ir1 3.32,5.32,8.00,13.32,20.00, 8.4,16.9,33.8,67.5,135,270 Low-voltage Distribution 26.66,33.30,45.00,60.00,93. 8.4,16.9,33.8,67.5,135,202.5, 270,337.5,405,472.5,540 32,133,200,266,333,400,43 3 3.0Ir1 1.25,2.00,3.00,5.00,7.50,10. 0,12.5,16.8,22.5,35.0,50.0,7 5.0,100,125,150,162 Short time Current setting Ir2=(1.5~15)In Ir2=(0.4~15)In Ir2=(1.5~15)In Accuracy ±15% ±10% ±10% Ts=K/10(N2-1),(Ts≥20ms) I2Ts=(8Ir1)2ts Ts=K/10(N2-1),(Ts≥20ms) Time setting(S) 0.1,0.2,0.3,0.4 0.1,0.2,0.3,0.4 0.1,0.2,0.3,0.4 Resettable time(S) 0.06,0.13,0.2,0.27 0.06,0.16,0.25,0.34 0.06,0.13,0.2,0.27 Action Inverse time-limit characteristics Definite time-delay Instantaneous ECWS-H ECW-H ECW-M CDW7-3200 CDW7-6300 CDW7-1000~6300A CDW7-2000 Current setting (1.0~20)ln Ir3=1In~50KA+OFF Ir3=1In~75KA+OFF IIr3=1In~100KA+OFF Accuracy ±15% ±15% Ir4=(0.2~1.0)In Ir4=(0.2~1.0)In Ir4=(0.2~1.0)In ±10% ±10% ±10% ±15% ±15% Earth fault Current setting Accuracy Action Inverse time-limit characteristics Definite time-delay Time setting 0.1s~1s (Rank difference 0.1s) 0.1~0.4s (Rank difference 0.1s) 0.1s~1s(Rank difference 0.1s) note:*pick-up shall not be crossed due to having three-stage protection simultaneously 70 CDW7 Air Circuit Breaker Standard: IEC 60947-2 Auxiliary Functions undervoltage release The undervoltage release automatically opens a circuit breaker when voltage drops to a value ranging between 35% to 70% of the line voltage. after tripping,the circuit breaker cannot be re-closed again when the voltage lowers than 35% or until returns to 85% of line voltage. Undervoltage release AC 380V AC220V (0.35~0.7)Ue (0.35~0.7)Ue (0.85~1.1)Ue (0.85~1.1)Ue ≤0.35Ue ≤0.35Ue CDW7-2000~6300 36VA 24VA CDW7-1000 5VA 5VA Rated operational voltage Operation voltage Ue V V Range of closing voltage V Range of non-closing voltage Consumption V Shunt release Power supply Us V AC380 AC220 DC220 Consumption CDW7-2000~6300 36VA 24VA 24W 24W CDW7-1000 5VA 5VA 5W 5W Operational voltage V DC110 (0.7~1.1)Us less than 30ms Breaking time Closing voltage release Closing release shall close the circuit breaker when supply voltage drops to a value ranging between 85% to 110% Closing voltage release Power supply Us V AC380 AC220 DC220 DC110 Consumption CDW7-2000~6300 36VA 24VA 24W 24W CDW7-1000 10VA 10VA 10W 10W Operational voltage Breaking time V (0.85~1.1)Us less than 70ms 71 Low-voltage Distribution Shunt release The shunt release shall open the circuit breaker when the supply drops to a value ranging between voltage rise between 70% to 110% of the line voltage CDW7 Air Circuit Breaker Standard: IEC 60947-2 Electric motor Motor operator shall complete energy storage when line voltage rise to between 85% to110% Motor operator structure Rated control power supply volage Us V AC380 AC220 DC220 DC110 85VA 85VA 85VA 85VA 2000~6300 2000A<In≤3200A 110VA 110VA 110VA 110VA 3200A<In≤6300A 150VA 150VA 150VA 150VA CDW7-1000 Operational voltage V 80VA 80VA 80VA 80VA Energy storage time less than 5s In≤2000A CDW7Power consumption (0.85~1.1)Us Low-voltage Distribution Auxiliary switch Making and breaking capacity of auxiliary contact under normal or abnormal conditions Utilizaiton category AC-15 Auxiliary contact default type Four normal open four normal close Conventional thermal current Ith 6A Auxiliary contact's energized operational Equal to circuit breaker operation performance performance Making& Under I/Ie making 10 1 breaking normal I/Iebreaking 1 1 capacity conditions U/Ue 1 1 cosΦor T0.95 0.3 6Pe* Under I/Ie 10 1.1 abnormal U/Ue 1.1 1.1 0.3 6Pe* 10 10 conditions cosΦor T0.95 operation cycles note:* when Pe≥50W,T0.95e’s upper limit≤300ms 72 DC-13 CDW7 Air Circuit Breaker Standard: IEC 60947-2 Overall Dimension Unit:mm CDW7-1000A fixed circuit breaker overall and mounting dimension horizonal/vertical connection diagram N 6 12 12 8 16 16 73 Low-voltage Distribution CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension Current rating (A) Pole L L1 L2 200, 400 3P 266 244 630 266 244 800, 1000 266 244 200, 400 4P 336 314 70 630 336 314 70 800, 1000 336 314 70 CDW7 Air Circuit Breaker Standard: IEC 60947-2 CDW7-1000A drawout circuit breaker overall and horizonal/vertical connection diagram Low-voltage Distribution CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring Current rating (A) 200, 400 630 800, 1000 200, 400 630 800, 1000 74 Pole 3P 4P L 284 284 284 354 354 354 L1 194 194 194 264 264 264 L2 70 70 70 L3 55 75 75 55 75 75 L4 63 83 83 63 83 83 N 6 12 12 8 16 16 H 6 8 10 6 8 10 CDW7 Air Circuit Breaker Standard: IEC 60947-2 CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical connection dimension(CDW7-2000) CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical wiring Type Pole L1 L2 L3 L4 In A a CDW7-2000* 3P 362 318 292 340 400~800 10 4P 457 413 292 435 1000~1600 15 457 413 292 435 2000 20 3P 422 378 352 400 2000~2500 20 4P 537 493 352 515 3200 30 CDW7-3200 note:* CDW7-2000 mounting dimension is same regardless of different current used in"horizonalwiring" or"vertical-wiring" 75 Low-voltage Distribution CDW7-2000A fixed circuit breaker vertical connection diagram CDW7 Air Circuit Breaker Standard: IEC 60947-2 door Low-voltage Distribution 76 CDW7 Air Circuit Breaker Standard: IEC 60947-2 CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection Type Pole CDW7-2000 1) 3P CDW7-3200 CDW7-6300 (4000/5000A) CDW7-6300 4P 3P 4P 3P 4P 3P L1 375 375 470 435 550 813 928 928 L2 335 335 430 395 510 773 888 888 L3 292 292 292 352 352 352 352 352 L4 265 265 360 325 440 703 818 818 L5 247 247 247 307 307 307 307 307 W1 461 461 461 471 471 494 494 494 W2 507 507 507 517 517 540 540 540 b 179 179 179 189 189 212 212 212 In A 400~800 1000~1600 2000 2000~2500 3200~4000 4000 5000~6300 5000~6300 a 10 15 20 20 30 20 30 30 note: 1) CDW7-2000 the mounting dimension is same regardless of different current used in"horizonal-connected" or "vertical-connected" CDW7-1000A drawout type CDW7-1000A fixed type CDW7-2000~6300 panel cut-out dimension CDW7-2000~6300A fixed type CDW7-2000~6300A drawout type CDW7-2000~6300 panel cut-out dimension and mounting dimension Type a b c 3P 4P CDW7-2000 306 346 0 47.5 CDW7-3200 366 406 0 57.5 CDW7-6300 366 406 189(4000/5000A) 246.5(4000/5000A) 246.5(6300A) -- 77 Low-voltage Distribution CDW7-1000 panel cut-out dimension CDW7 Air Circuit Breaker Standard: IEC 60947-2 Auxiliary connection diagramn ■ ECWS-H type intelligent release unit connection diagram Low-voltage Distribution 1:Q、F、X with different current ratings shall connect with different sources. ■ 2:If users have special requirements£¬the auxiliary switches can reach up to a maximum of 6ON6OFF. At this condition, the 45 - 49 output terminals will become the auxiliary switch contacts. For the detailed wiring diagram , please see the dotted line part of the diagram. At this time, the external sensor and supplementary functions are not available. ■ 78 ■ Sign interpretation in connection diagram: ----Connected by user ----Connected by manufacturer SB1 shunt pushbutton(self-prepared) SB2 close pushbutton SB3 undervoltage pushbutton(self-prepared) X closing voltage release FU fuse F closing voltage release DF auxiliary switch SA electrical path switch M electric motor Q undervoltage instantaneous lamp(self-prepared) (or time-delay) release XT circuit breaker wiring terminal 41、42 when controller power choose DC,the output is DC24V,user can select DC power module □ 43、44 circuit breaker status detection terminal(used when MCR function included) □ 45 overload pre-alarm signal output □ 46 automatic diagnosis alarm signal output □ 47 fault trip alarm signal output □ 48 earthing but non-tripping,only alarm signal output □ 49 four groups of contacts output common terminal □ 50、51 externally sensor input terminal □ 58 able to directly connect to power supply(automatic pre-energization),also able to join up with normal open pushbutton to connect to power supply(manual preenergization) □ CDW7 Air Circuit Breaker Standard: IEC 60947-2 ■ ECW-M intelligent release connection diragram Components: Q - Under-voltage release F - Shunt release X – Closing electromagnet DF - Auxiliary switch M - Motor SB1—Button for closing SB2—Button for shunt Note: 1. If the control voltage values of Q, F, X, and M are different to each other, these components can be connected to different power supply units; in the application, the shunt release and closing electromagnet shall be connected serially with normally open and normally closed auxiliary contacts (the part enclosed by dotted lines shall be connected by the user; the part represented by a two-dot chain line is the wiring of circuit 51); Note 2: The pin 35# can be connected to the power supply directly (automatic pre-energy storage) or connected serially to a normally open button and then to the power supply (manual pre-energy storage); Note 3: If the user requests, pin #6~#7 can be connected to normally closed contacts; Note 4: The ECW power supply module I is a DC power supply module, and it can be omitted if the power supply is AC power supply; the polarity and lead-ins/lead-outs shall not be reversed (for draw-out type circuit breakers, the lead-outs of the power supply module has been connected before the circuit break is shipped from the factory); Note 5: In case of circuit 47, the auxiliary contacts are four closed and four open contacts; pin #25 and #26 are input terminals of an external current transformer , used for earth fault protection as (3P+N)T type ; Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open contacts (or five closed and five open contacts); pin #25, #26, and #51 form normally open and normally closed contacts; Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module and other conversion modules must be ordered; ECW power supply module lV and ECW201 relay module must be ordered separately; Note 8:Pin #12~#19 input/output contacts can be user-defined programmable signal contacts. 79 Low-voltage Distribution Pin functions: Pin 1# and 2#: Auxiliary power input,pin 1# is positive for DC input Pin 3#, 4#, 5#: Fault trip contact output (4# is common terminal); contact capacity: AC380V, 16A Pin 6# and 7#, 8# and 9#: Two groups of auxiliary contacts for breaker status; contact capacity: AC380V, 16A 12#,13#(Contact1)and 14#,15#(Contact2)and 16#,17#(Contact3)and 18#,19#(Contact4):Output of four groups of signal for controllers,contact capacity:4A/240V 7A/24VDC 20#: Earth protection 21#~24#:input of voltage signal (Note:the order cant be wrong) CDW7 Air Circuit Breaker Standard: IEC 60947-2 ECW-H intelligent release connection diagram ■ Low-voltage Distribution 1: different power supply can be connected respectively if ■ ■ the control supply voltage of Q、F、X、M are different the shunt release、closing release shall respectively,join up with normal open、normal close auxiliary contacts(the broken line part of diagram is connected by user own;double point line is 51 circuit connection) 2: terminal 35# can directly connect to power supply ■ (automatic pre-energy storage),or join up with normal open pushbutton to connect power supply(manual pre-energy storage) 3: terminal 6#~7# can lead out normal close contact if user ■ suggested 4: ECW power supply module is DC power supply module, ■ the module doesn't exist when power supply current is AC,polarity,incoming line and leading-out line shall not connected reversely(leading-out terminal of power supply module in drawout type had been connected before sale) 5: in 47 circuit,auxiliary contact is 4 open 4 close;25#、26# is ■ input terminal of external sensor 6: in 51 circuit,auxiliary contact is 6open6close(5open ■ 5close);25#、26#、51# form normal open normal close contact(earth-leakage protection excluded) ■ 7: if using profibus or other protocols, user shall order ECWH+HP transformation module and others;ECW power supply moduleV,ECW201 relay module and others shall order seperately 8: #12~#19 output input contacts are programmableself- ■ defined signal contaccts 80 components: Q- undervoltage release F- shunt release X- closing voltage release DF- auxiliary switch M- electric motor Pin function: 1#、2#: 1# is the front terminal when DC is supplied by auxiliary power □ 3#、4#、5#: fault trip contact output(4 is the common termincaoln)contact capacit: AC380V、16A □ 6#、7#和8#、9#: two groups of circuit breaker status auxiliary terminal: contact capacit:AC380V、16A □ 10#、11#: respectively as the communication leading-out of RS485A ,RS485B □ 12#: overload pre-alarm signal output □ 13#: communication remote control shunt release output □ 14#: communication remote control closing output or instantaneous short time-delay trip signal output □ 15#: communication remote control energy storage or long time-delay trip signal output □ 16#: S-earth(RS-485 transmissionn common ground wire □ 17#: load monitor output1 □ 18#: load monitor signal 2 □ 19#: signal output common earth wire □ 20#: PE line ,shield earth wire □ 21#: neutral voltage signal N phase □ 22#: voltage signal A phase □ 23#: voltage signal B phase □ 24#: voltage signal C phase ■ □ CDW7 Air Circuit Breaker Standard: IEC 60947-2 Other Additional Parameter ■ ECWS-H ECW-H overcurrent proteciton curver ECW-M overcurrent protection curve 81 Low-voltage Distribution ■ CDW7 Air Circuit Breaker Standard: IEC 60947-2 Order Instruction Customer Sets purchased Date Mode CDW7 Fixed Draw-out Rated voltage AC400 AC690 Low-voltage Distribution H Type Intelligent electronic trip Basic function 3 Poles 4Poles Rated current In= A Overload long delay Short-circuit short Short-circuit instantaneous time protection delay time protection protection Earthing protection Load monitoring function Metering function (Not available for L type) Power supply AC 230V AC 400V DC 220V DC 110V Under-voltage instantaneous trip AC 230V Under-voltage time-delay trip 1s AC 400V Under-voltage trip 3s 5s Accessaries Shunt trip AC 230V AC 400V DC 220V DC 110V Energy releasing electromagnet AC 230V AC 400V DC 220V DC 110V Motor Driven AC 230V AC 400V DC 220V DC 110V Interphase barrier Escutcheon N phase external connection Earth-leakage CT(Only for cable) Auxiliary switch standard(4a4b) special(6a6b) Auxiliary Connection Terminal Mechanical interlock 1-lock,1-key 2-lock,1-key Steel-cable interlock Interlocking rod with 2 switches Interlocking rod with 3 switches Door interlock(Available for Draw-out type) Note:for any special requirement,please contact with the manufacturer. 82 3-lock, 2-key Contents Motor Control & Protection Contactor&Thermal Overload Relay 86-127 CDC17-K Mini AC Contactor 86 CDC17 AC Contactor 89 CDR17 Thermal Overload Relay 100 CJX2 AC Contactor 106 JRS1D Thermal Overload Relay 112 CJX2-F AC Contactor 117 JRS2 Thermal Overload Relay 123 Definite Purpose Contactor 128-134 CDC9 Switching Capacitor Contactor 128 CDCK8 Air Condition Contactor 131 135-146 CDZ17 Contactor Relay 135 CDZ8 Miniature Relay 139 JSZ3 Electronic Time Relay 143 XJ9 Phase Failure and Sequence Protection Relay 146 83 Motor Control & Protection Relay Motor Control and Protection Product Overview Contactor Thermal Overload Relay CDC17-K 86 100 Current:6-12A Pole:3P,4P Coil Voltage:AC24-400V Setting Current:0.1-18A Trip class:10A CDC17 CDR17 89 Current:9-185A Pole:3P Coil Voltage:AC24-400V CDC17 89 Motor Control & Protection Current:115-1000A Pole:3P Coil Voltage:AC110-400V CJX2 106 100 Setting Current:0.1-185A Trip class:10A, 10 JRS2 123 Setting Current:55-630A Trip class:10A,10 JRS1D 112 Current:9-95A Pole:3P Coil Voltage:AC36-400V Setting Current:0.1-93A Trip class:10A,10 CJX2-F JRS2 117 Current:115-630A Pole:3P Coil Voltage:AC36-400V 84 CDR17-18 123 Setting Current:55-630A Trip class:10A,10 Motor Control and Protection Product Overview Definite Purpose Contactor CDC9 128 CDCK8 131 Current: 25-65A Poles: 3P Current: 25-45A Poles: 1P,2P Application: Power factor correction Application: Air Conditioner Features: A unique limiting module Effectively inhibit the inrush current Features: Compact Convenient and reliable connection Suitable for high-temperature enviroment Motor Control & Protection Control Relay CDZ8 139 Contact: 2Z,3Z,4Z Coil Voltage: AC6-220V DC6-220V Features: PCB type and plug-in type are availble Convenient installation High sensitivity Wide range of application CDZ17 135 Contact: 13, 22, 31, 40, 04, 44, 53, 62, 71, 80 Coil Voltage: AC36-380V DC22-440V Features: Large capacity of contacts Scalable accessories Longer life 85 CDC17-K Mini AC Contactor Standard: IEC 60947-4-1 Function CDC17-K AC contactor provide: □ Remote make & break of circuits □ Frequent start and stop of motors Order Information Moter P(kW) 380V Rated current(A) 2.2 6 4 9 4 Auxiliary contact Main contact 12 Reference Motor Control & Protection NO NC NO NC 3 0 1 0 CDC17K63010*· 3 0 0 1 CDC17K63001*· 4 0 0 0 CDC17K64000*· 2 2 0 0 CDC17K62200*· 3 0 1 0 CDC17K93010*· 3 0 0 1 CDC17K93001*· 4 0 0 0 CDC17K94000*· 2 2 0 0 CDC17K92200*· 3 0 1 0 CDC17K123010*· 3 0 0 1 CDC17K123001*· 4 0 0 0 CDC17K124000*· Reference Description CDC17-K 6 30 10 * · Coil Frequency Coil Voltage Auxiliary contact Main contact Rate current Model Coil voltage code coil voltage * 24V 36V 110V 127V 220V 380V 400V B C F S M Q V Coil frequency code 86 coil frequency 50Hz 60Hz · 5 6 CDC17-K Mini AC Contactor Standard: IEC 60947-4-1 Technical Data Model CDC17-K06 CDC17-K09 CDC17-K12 Main circuit characteristics Rated operational current 380V/400V, AC-3 A 6 9 12 380V/400V, AC-4 A 2.6 3.5 5 660V/690V, AC-3 A 3.5 5 6 660V/690V, AC-4 1.5 2 A 1.2 Rated operational voltage V 220/230, 380/400, 660/690 Rated insulation voltage V 690 Rated conventional thermal current A 16 Pole Power of controlled 3-phase cage motor 3, 4 220V/230V, AC-3 kW 1.5 2.2 3 380V/400V, AC-3 kW 2.2 4 4 5.5 7.5 kW 3 AC-3 ×104 operations 100 cycles/h 1200 ×104 operations 20 Operating rate cycles/h 600 Mechanical durabilities ×104 cycles 1000 Operating rate Electric durabilities AC-4 Matched Fuse Cable connection RT16-16 Inflexible cable number of piece Cross Section of Cable mm2 Motor Control & Protection 660V/690V, AC-3 Electric durabilities 20 RT16-20 2 4 Coil Coil voltage(Us) V AC 24,36,110,127,220,380,400 Operational voltage V 85%~110% Us Drop-out voltage V 20%~75% Us Inrush VA 30 Sealed VA 4.5 Rated conventional thermal current V 690 Rated insulation voltage A 10 Rated operational current 380V, AC-15 A 0.95 220V, DC-13 A 0.15 AC-15 VA 360 DC-13 W 33 Auxliary contact Control capacity 87 CDC17-K Mini AC Contactor Standard: IEC 60947-4-1 Working Conditions ■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures ■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and shock and vibration place Install Location Motor Control & Protection Overall Dimensions 88 CDC17 AC Contactor Standard: IEC 60947-4-1 Order Information Moter P(kW) 380V Rate current (A) 4 9 12 5.5 18 7.5 25 11 32 15 10 * NC 1 0 CDC17910* 0 1 CDC17901* 1 0 CDC171210* 0 1 CDC171201* 1 0 CDC171810* 0 1 CDC171801* 1 0 CDC172510* 0 1 CDC172501* 1 0 CDC173210* 0 1 CDC173201* 40 1 1 CDC174011* 22 50 1 1 CDC175011* 30 65 1 1 CDC176511* 37 80 1 1 CDC178011* 45 95 1 1 CDC179511* 55 115 2 2 CDC1711522* 75 150 2 2 CDC1715022* 90 185 2 2 CDC1718522* 110 225 2 2 CDC1722522* 132 265 2 2 CDC1726522* 160 330 2 2 CDC1733022* 220 400 2 2 CDC1740022* 265 500 2 2 CDC1750022* 335 630 2 2 CDC1763022* 450 800 2 2 CDC1780022* 560 1000 2 2 CDC17100022* Motor Control & Protection 9 Reference NO 18.5 Reference Description CDC17 Auxiliary contact Coil voltage code · coil voltage 24V 36V 110V 127V 220V 380V 400V * B C F S M Q V Coil Frequency Coil Voltage Auxiliary contact Rate current Model Coil frequency code coil frequency 50Hz 5 60Hz 6 89 CDC17 AC Contactor Standard: IEC 60947-4-1 Technical Data CDC17-9 CDC17-12 CDC17-18 CDC17-25 CDC17-32 380V / 400V, AC-3 A 9 12 18 25 32 380V / 400V, AC-4 A 3.5 5 7.7 8.5 12 660V, AC-3 A 6.6 8.9 12 18 21 660V, AC-4 A 1.5 2 3.8 4.4 7.5 660 Model Main circuit characteristics Rated operational current Rated operational voltage V 380 / 400 Rated insulation voltage V 690 Rated conventional thermal current A 20 20 32 40 50 4 5.5 7.5 11 15 5.5 7.5 9 15 18.5 Power of controlled 380V/400V, AC-3 kW 3-phase cage motor 660V, AC-3 kW AC-3 ×10 operations 100 Electric durabilities Operating rate cycles/h Electric durabilities ×10 operations 20 AC-4 Operating rate 1200 4 cycles/h Mechanical durabilities 80 4 300 800 Motor Control & Protection ×10 cycles 1000 Coil voltage(Us) V AC 24, 36, 48, 110, 127, 220, 230, 380, 400 Operational voltage V 85%~110%Us Drop-out voltage V 20%~75%Us Inrush VA 70 110 Sealed VA 8 11 Heat dissipation W 1.8~2.7 3~4 4 Coil Accessories Auxiliary contact Time-delay block Front mount CDF4 Side mount - Front mount CDLA2 or CDLA3 Mechanical Interlock CDJL17-1 Matched Relay CDR17-18 Matched Fuse Cross Section of Cable RT16-20 Number of Piece Flexible cable Inflexible cable Weight 90 CDR17-32 1 2 1 2 RT16-32 RT16-40 RT16-50 1 1 1 2 2 mm 2 2.5 4 6 mm 2 4 6 10 0.315 0.335 Kg 0.513 0.510 2 CDC17 AC Contactor Standard: IEC 60947-4-1 Technical Data CDC17-40 CDC17-50 CDC17-65 CDC17-80 CDC17-95 380V / 400V, AC-3 A 40 50 65 80 95 380V / 400V, AC-4 A 18.5 24 28 37 44 Model Main circuit characteristics Rated operational current 660V, AC-3 A 34 39 42 49 55 660V, AC-4 A 9 12 14 17.3 21.3 Rated operational voltage V 380 / 400 660 Rated insulation voltage V 690 Rated conventional thermal current A 60 80 80 125 125 18.5 22 30 37 45 30 33 37 45 45 Power of controlled 380V/400V, AC-3 kW 3-phase cage motor 660V, AC-3 kW AC-3 ×10 operations 80 Electric durabilities Operating rate Electric durabilities 4 cycles/h AC-4 60 1200 ×104 operations 20 cycles/h 300 4 ×10 cycles 800 Coil voltage(Us) V AC 24, 36, 48, 110, 127, 220, 230, 380, 400 Operational voltage V 85%~110%Us Drop-out voltage V 20%~75%Us Inrush VA 200 Sealed VA 20 Heat dissipation W 6~10 Operating rate Mechanical durabilities 600 Motor Control & Protection Coil Accessories Auxiliary contact Time-delay block Front mount CDF4 Side mount - Front mount CDLA2 or CDLA3 Mechanical Interlock CDJL17-2 Matched Relay CDR17-95 Matched Fuse Cross Section of Cable Number of Piece Flexible cable Inflexible cable Weight RT16-63 RT16-80 1 1 mm 2 10 mm 2 16 Kg 1.14 2 2 16 - 25 RT16-100 RT16-125 RT16-200 1 1 2 1 2 50 25 50 25 - 50 - 2 25 - 25 - 50 1.35 91 CDC17 AC Contactor Standard: IEC 60947-4-1 Technical Data CDC17-115 CDC17-150 CDC17-185 CDC17-225 CDC17-265 CDC17-330 Model Main circuit characteristics Rated operational current 380V/400V, AC-3 A 115 150 185 225 265 330 380V/400V, AC-4 A 52 60 79 85 105 117 660V, AC-3 A 86 110 118 135 170 225 660V, AC-4 69 82 98 118 A 49 61 Rated operational voltage V 380 / 400 660 Rated insulation voltage V 690 Rated conventional thermal current A 150 150 210 225 300 330 Power of controlled 380V/400V, AC-3 kW 55 75 90 110 132 160 3-phase cage motor 660V, AC-3 kW 80 100 110 129 160 220 AC-3 ×10 operations 60 Electric durabilities 4 cycles/h Electric durabilities ×10 operations 20 AC-4 300 1200 Operating rate 4 30 cycles/h 300 4 ×10 cycles 600 Coil voltage(Us) V AC110,127,220,230,380,400 Operational voltage V 85%~110%Us Drop-out voltage V 20%~75%Us Inrush VA 559 695 1198 Sealed VA 33 45 83 9.5~14 13~15 18~25 Operating rate Mechanical durabilities 600 Motor Control & Protection Coil Heat dissipation W Accessories Auxiliary contact Time-delay block Front mount - Side mount CDFC17-11,CDFC17-12 Front mount - Mechanical Interlock CDJL17-3 Matched Relay CDR17-185 Matched Fuse RT16-200 Cross Section of Cable Weight 92 JRS2-400 RT16-250 RT16-250 RT16-400 1 2 1 2 1 2 1 2 1 2 1 2 Flexible cable mm2 95 50 120 - 150 - 185 - 240 - 240 - Inflexible cable mm2 - 20x3 - 25x3 - 25x3 - Kg 2.15 Number of Piece 32x4 6.6 32x4 6.6 30x5 CDC17 AC Contactor Standard: IEC 60947-4-1 Technical Data Model CDC17-400 CDC17-500 CDC17-630 CDC17-800 CDC17-1000 380V / 400V, AC-3 A 400 500 630 800 1000 380V / 400V, AC-4 A 138 147 188 242 - 660V, AC-3 A 305 355 460 530 580 660V, AC-4 170 215 - Main circuit characteristics Rated operational current A 135 145 Rated operational voltage V 380 / 400 660 Rated insulation voltage V 690 Rated conventional thermal current A 500 500 800 800 1000 Power of controlled 380V/400V, AC-3 kW 220 265 335 450 560 3-phase cage motor 660V, AC-3 kW 280 335 450 500 560 Electric durabilities AC-3 Operating rate Electric durabilities 4 ×10 operations 60 cycles/h AC-4 Operating rate ×10 operations 20 cycles/h Mechanical durabilities 300 4 4 30 ×10 cycles 600 Coil voltage(Us) V AC110,127,220,230,380,400 Operational voltage V 85%~110%Us Drop-out voltage V 20%~75%Us Inrush VA 780 1050 Sealed VA 10 12 Heat dissipation W 8~14 10~18 600 Motor Control & Protection Coil Accessories Auxiliary contact Time-delay block Front mount - Side mount - Front mount CDFC17-21 Mechanical Interlock - Matched Relay JRS2-400 JRS2-630 Matched Fuse RT16-500 RT16-630 RT16-800 RT17-4/1000 150 185 240 - 30x5 40x5 50x5 60x5 Cross Section of Cable Number of Piece Flexible cable Inflexible cable Weight RT17-4/-1250 2 mm2 mm Kg 2 9.36 80x5 22.8 93 CDC17 AC Contactor Standard: IEC 60947-4-1 CDC17-9~95 Contactor Accessories Top of auxiliary contact Mechanical interlocking module Air delay head Motor Control & Protection Thermal overload relays Contactor 9 12 25 32 40 50 Top of auxiliary contact 2 Poles:CDF411,CDF402,CDF420 4 Poles:CDF404,CDF413,CDF422,CDF431,CDF440 Air delay head Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4 Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4 Mechanical interlocking module CDJL171,CDJL17265,CDJL17295 CDR17-18 Thermal 0.1-0.13-0.15A overload relays … 14-16-18 94 18 CDR17-32 4.5-5-6.3A … 23-25-32 CDR17-95 9-10-12A … 75-80-95A 65 80 95 CDC17 AC Contactor Standard: IEC 60947-4-1 CDC17-115~1000 Contactor Accessories Top of auxiliary contact Mechanical interlocking module Side auxiliary contact Air delay head Thermal overload relays 115 150 185 225 265 330 400 500 Top of auxiliary contact 2 Poles:CDF411,CDF402,CDF420 4 Poles:CDF404,CDF413,CDF422,CDF431,CDF440 Only applicable for CDC17-115~330 Air delay head Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4 Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4 Only applicable for CDC17-115~330 Side auxiliary contact CDFC1711,CDFC1721,CDFC1712 Only applicable for CDC17-115~500 Mechanical interlocking module CDJL173150,CDJL173225,CDJL173330 Only applicable for CDC17-115~330 JRS2-180 Thermal 55-88A overload relays … 150-180A JRS2-400 80-125A … 250-400A 630 800 1000 JRS2-630 320-500A 400-630A Only applicable for CDC17-115~630 95 Motor Control & Protection Contactor CDC17 AC Contactor Standard: IEC 60947-4-1 Accessories CDF4 Top of auxiliary contact Pole Contact Reference Recommended Contactor 1 CDF411 CDC17 115~330 0 2 CDF402 CDC17 115~330 2 0 CDF420 CDC17 115~330 0 4 CDF404 CDC17 115~330 1 3 CDF413 CDC17 115~330 2 2 CDF422 CDC17 115~330 3 1 CDF431 CDC17 115~330 4 0 CDF440 CDC17 115~330 Delay Range Reference Recommended Contactor 0.1-3S CDLA2ON0 CDC17 115~330 0.1-30S CDLA2ON2 CDC17 115~330 10-180S CDLA2ON4 CDC17 115~330 0.1-3S CDLA3OFF0 CDC17 115~330 0.1-30S CDLA3OFF2 CDC17 115~330 10-180S CDLA3OFF4 CDC17 115~330 Reference Recommended Contactor CDFC1711 CDC17 115~330 CDFC1721 CDC17 115~330 CDFC1712 CDC17 115~330 NO NC 1 Wiring diagram 2P 4P Motor Control & Protection CDLA Air delay head Delay Type Wiring diagram Making time-delay Breaking time-delay CDFC17 Side auxiliary contact Pole 2P Contact NO NC 1 1 2 1 Wiring diagram 13 23 31 3P 14 24 32 1 96 2 CDC17 AC Contactor Standard: IEC 60947-4-1 Accessories Mechanical interlocking module Contactor Specifications Reference CDC17-9~32A CDJL171 CDC17-40~65A CDJL17265 CDC17-80~95A CDJL17295 CDC17-115~150A CDJL173150 CDC17-185~225A CDJL173225 CDC17-265~330A CDJL173330 Working Conditions Motor Control & Protection ■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures ■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and shock and vibration place Install Location 97 CDC17 AC Contactor Standard: IEC 60947-4-1 Overall Dimensions CDC17-9~32 a 2- d CDC17-40~95 3 d Motor Control & Protection Type Amax Bmax Cmax C1max C2max a b c CDC17-9~12 45 68 77 109 133 35±0.21 59±0.28 4.5 CDC17-18 45 68 82 115 138 CDC17-25 56.5 79 91 124 149 40±0.21 66±0.43 4.5 CDC17-32 56.5 40±0.21 105±0.57 6.5 79 95 127 152 CDC17-40~65 75 127 115 145 170 CDC17-80~95 85 127 123 153 178 Note:C1max-Contactor+CDF4 98 C2max-Contactor+CDLA CDC17 AC Contactor Standard: IEC 60947-4-1 CDC17-115~150 CDC17-185~330 A A1 B C C1 a1 a2 a3 b1 b2 Φ b3 Φ1 CDC17-185 138 111 180 163 95 40 20 80 158 154 9 150 7 CDC17-225 138 111 199 163 95 48 25 80 172 172 11 150 7 CDC17-265, 330 171 144 207 201 119 48 25 96 180 180 11 166 11 Motor Control & Protection Type CDC17-400~500 48 48 CDC17-630~1000 99 CDR17 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Function CDR17 series thermal overload relay provide: □ Protection of circuits and motors against overload □ Protection of circuits and motors against phase loss □ Motor starters installation in association with contactors Order Information Reference Description CDR17 18 P15 Setting current Rated current Model Type Rated insulation voltage Ui V CDR17-18 690 Range of current setting A Reference Recommended contactor 18 0.1~0.13~0.15 CDR1718P15 CDC17-9~18 0.12~0.16~0.18 CDR1718P18 CDC17-9~18 0.18~0.2~0.25 CDR1718P25 CDC17-9~18 0.25~0.32~0.36 CDR1718P36 CDC17-9~18 0.35~0.4~0.5 CDR1718P5 CDC17-9~18 0.5~0.6~0.7 CDR1718P7 CDC17-9~18 0.63~0.72~0.9 CDR1718P9 CDC17-9~18 0.9~1~1.2 CDR17181P2 CDC17-9~18 1.2~1.6~1.8 CDR17181P8 CDC17-9~18 1.8~2~2.5 CDR17182P5 CDC17-9~18 2.5~3.2~3.6 CDR17183P6 CDC17-9~18 3.5~4~4.8 CDR17184P8 CDC17-9~18 4.5~5~6.3 CDR17186P3 CDC17-9~18 5~6~7 CDR17187 CDC17-9~18 6.3~7.2~9 CDR17189 CDC17-9~18 9~10~12 CDR171812 CDC17-9~18 11~13~15 CDR171815 CDC17-9~18 14~16~18 CDR171818 CDC17-9~18 4.5~5~6.3 CDR17326P3 CDC17-25~32 5~6~7 CDR17327 CDC17-25~32 6.3~7.2~9 CDR17329 CDC17-25~32 9~10~12 CDR173212 CDC17-25~32 12~16~18 CDR173218 CDC17-25~32 18~20~25 CDR173225 CDC17-25~32 23~25~32 CDR173232 CDC17-25~32 Motor Control & Protection Frame size rated current CDR17-32 690 100 32 CDR17 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Order Information Type Rated insulation voltage Ui V CDR17-95 690 CDR17-185 690 Range of current setting A Reference Recommended contactor 95 9~10~12 CDR179512 CDC17-40~95 12~16~18 CDR179518 CDC17-40~95 18~20~25 CDR179525 CDC17-40~95 23~25~32 CDR179532 CDC17-40~95 30~36~40 CDR179540 CDC17-40~95 37~45~50 CDR179550 CDC17-40~95 48~55~65 CDR179565 CDC17-40~95 55~63~70 CDR179570 CDC17-40~95 63~70~80 CDR179580 CDC17-40~95 75~90~95 CDR179595 CDC17-40~95 37~45~50 CDR1718550 CDC17-115~185 48~55~65 CDR1718565 CDC17-115~185 55~63~70 CDR1718570 CDC17-115~185 63~70~80 CDR1718580 CDC17-115~185 75~90~95 CDR1718595 CDC17-115~185 90~100~115 CDR17185115 CDC17-115~185 105~115~135 CDR17185135 CDC17-115~185 120~135~150 CDR17185150 CDC17-115~185 130~150~160 CDR17185160 CDC17-185 150~160~185 CDR17185185 CDC17-185 185 101 Motor Control & Protection Frame size rated current CDR17 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Technical Data Temperature compensation -10℃~+55℃ Trip class10A CDR17-18, 32, 95 CDR17-185 10 Rated insulation voltage Ui V 690V Structure characteristics Overload protection Yes Phase-failure protection Yes Manual reset Yes Automatic reset Yes Stop button Yes Test button Yes Trip direction Yes Tolerance on slope in any direction ±22.5° Control circuit Motor Control & Protection 102 Utilization category AC-15 Rated frequency Hz 50 50 50 Rated insulation voltage Ui V 690 690 690 690 Rated operational voltage Ue V 220/230 380/400 660/690 Rated operational current Ie A 1.64/1.57 0.95/0.9 0.55/0.52 0.23/0.22 Conventional free air thermal current Ith A 6 6 6 Contact circuit Utilization category AC-15 DC-13 Rated frequency Hz 50 Rated insulation voltage Ui V 690 690 Rated operational voltage Ue V 660/690 220/230 Rated operational current Ie A 6 6 Conventional free air thermal current Ith A 6 6 DC-13 6 220/230 CDR17 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Trip Characteristic Trip time Multiples of Sequence setting current Trip class 10A Initial condition Ambient temperature >2h From cold state +20℃ <2h From hot state(immediately following sequence 1 test) Trip class 10 Limits of operation of relays when energized on all poles 1 1.05 2 >2h 1.2 <2h 3 1.5 <2min <4min From hot state(immediately following sequence 1 test) 4 7.2 2s<Tp≤10s 4s<Tp≤10s From cold state +20℃ >2h From cold state +20℃ <2h From hot state(immediately following sequence 1 test) Limits of operation when energized on two poles 1 1.0 2 1.15 0.9 0 >2h <2h Motor Control & Protection Any two The thirdpoles pole Accessories Base Name Thermal Overload Relay Reference CDR17-18 CDR1718J CDR17-32 CDR1732J CDR17-95 CDR1795J 103 CDR17 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Work conditions Ambient temperature: -10℃~+55℃, daily average temperature ≤35℃ Altitude: ≤2000m Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3 Installation conditions Installation Type: Ⅲ Installation position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 22.5° 22.5 22.5 Motor Control & Protection 360° Wire Connection Picture FU-Fuse KM-Contactor FR-Relay SB1-Stop Button SB2-Start Button 104 CDR17 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Overall Dimensions CDR17-18 ■ CDR17-32 ■ CDR17-95 ■ CDR17-185 Motor Control & Protection ■ 105 CJX2 AC Contactor Standard: IEC 60947-4-1 Function CJX2 AC contactors provide: □ Remote make & break of circuits □ Frequent start and stop of motors Order Information Rated current(A) Motor P(kW) 380V 5.5 Auxiliary contact NO 9 7.5 12 10 18 15 25 18.5 32 Reference NC Motor Control & Protection 1 0 CJX2910*· 0 1 CJX2901*· 1 0 CJX21210*· 0 1 CJX21201*· 1 0 CJX21810*· 0 1 CJX21801*· 1 0 CJX22510*· 0 1 CJX22501*· 1 0 CJX23210*· 0 1 CJX23201*· 30 40 1 1 CJX24011*· 33 50 1 1 CJX25011*· 37 65 1 1 CJX26511*· 45 80 1 1 CJX28011*· 55 95 1 1 CJX29511*· Reference Description CJX2 9 10 * · Coil Frequency Coil Voltage Auxiliary contact Rate current Model Coil voltage code coil voltage * 36V 110V 127V 220V 380V 400V C F S M Q V Coil frequency code coil frequency · 106 50Hz 5 60Hz 6 CJX2 AC Contactor Standard: IEC 60947-4-1 Technical Data Model CJX2-09 CJX2-12 CJX2-18 CJX2-25 CJX2-32 CJX2-40 CJX2-50 CJX2-65 CJX2-80 CJX2-95 Main circuit characteristics Rated operational voltage V 380, 660 Rated insulation voltage V 690 Conventional thermal current A 25 25 32 40 50 60 80 80 125 125 12 18 25 32 40 50 65 80 95 39 42 Rated operational 380V, AC-3 A 9 current 380V, AC-4 A 3.5 5 7.7 18 21 34 49 55 660V, AC-3 A 6.6 8.9 12 8.5 12 18.5 24 28 37 44 660V, AC-4 A 1.5 2 3.8 4.4 7.5 9 12 14 17.3 21.3 Power of controlled 220V, AC-3 kW 4 5.5 7.5 11 15 18.5 22 30 37 45 3-phase cage 380V, AC-3 kW 5.5 7.5 10 15 18.5 30 33 37 45 55 motor 660V, AC-4 kW 2.2 3 4 5.5 7.5 11 15 18.5 22 25 4 AC-3 ×10 operations 100 80 80 60 4 AC-4 ×10 operations 20 20 15 10 Electric durabilities 4 Mechanical durabilities Operating rate ×10 cycles 1000 800 800 600 AC-3 cycles/h 1200 600 600 600 AC-4 cycles/h 300 300 300 300 RT16-20 RT16-20 RT16-32 RT16-40 RT16-50 RT16-63 RT16-80 RT16-80 RT16-100 RT16-125 Cable connection cross section mm2 1.5 1.5 2.5 4 6 10 16 16 25 35 Coil Coil voltage(Us) V AC36,110,127,220,380,400 Operational voltage V 85%~110%Us Drop-out voltage V 20%~75%Us Inrush VA 70 110 200 Sealed VA 8 11 20 Heat dissipation W 1.8~2.7 3~4 6~10 Front mount F4 Side mount FC6 Accessories Auxiliary contact Time-delay block Front mount SK4 FR632H Mechanical Interlock Rated conventional thermal current A 10 Rated operational voltage AC V 380 DC V 220 Rated control capacity AC-15 VA 360 DC-13 W 33 FR695HX 107 Motor Control & Protection Matched Fuse CJX2 AC Contactor Standard: IEC 60947-4-1 CJX2 Contactor Accessories Mechanical interlocking module Top of auxiliary contact Side auxiliary contact Air delay head Thermal overload relays Motor Control & Protection Contactor 9 Top of auxiliary contact Side auxiliary contact Air delay head Mechanical interlocking module Thermal overload relays 108 12 18 25 32 40 50 2 Poles:F411,F402,F420 4 Poles: F404,F413,F422,F431,F440 2 Poles: FC611, FC602, FC620 Making time-delay: SK420,SK422,SK424 Breaking time-delay: SK430,SK432,SK434 9-32A: FR632H 40-95A: FR695HX JRS1D-25 0.1-0.16A ... 17-25A JRS1D-36 23-32A 30-40A JRS1D-93 23-32A ... 80-93A 65 80 95 CJX2 AC Contactor Standard: IEC 60947-4-1 Accessories F4 Top of auxiliary contact Pole 2P 4P Contact Wiring diagram Reference NC 1 1 F411 0 2 F402 2 0 F420 0 4 F404 1 3 F413 2 2 F422 3 1 F431 4 0 F440 Motor Control & Protection NO SK4 Air delay head Delay Type Wiring diagram Making timedelay Breaking time-delay Delay Range Reference 0.1-3S SK420 0.1-30S SK422 10-180S SK424 0.1-3S SK430 0.1-30S SK432 10-180S SK434 FC6 Side auxiliary contact Pole Contact NO NC 0 2 Wiring diagram Reference 51 61 2P 1 2 FC602 52 62 53 61 54 62 53 63 FC611 1 FC620 0 54 64 109 CJX2 AC Contactor Standard: IEC 60947-4-1 Accessories Mechanical interlocking module Contactor Specifications Reference CJX2-9~32 FR632H CJX2-40~95 FR695HX Working Conditions Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures ■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and shock and vibration place ■ ■ Motor Control & Protection Install Location 110 CJX2 AC Contactor Standard: IEC 60947-4-1 Overall Dimensions Unit:mm CJX2-09~32 CJX2-40~95 Motor Control & Protection Product Type Amax Bmax Cmax C1max C2max a b d CJX2-09~12 47 76 82 115 115 35 50/60 4.5 CJX2-18 47 76 87 120 120 CJX2-25 57 86 97 130 130 40 50/60 4.5 CJX2-32 57 86 102 135 135 CJX2-40~65 77 129 116 149 149 40 100/110 6.5 CJX2-80~95 127 87 160 160 129 Note: C1max is auxiliary contact group +F4 C2max is air-delay contact+SK4 111 JRS1D Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Function JRS1D relay provide: □ Protect motor and circuit □ Possess overload and phase failure protection functions. Order Information Reference Description JRS1D 25 P16 Setting current Rated current Model Current setting(A) Reference Recommended contactor Recommended fuse 25 0.1~0.16 JRS1D25P16 CJX2-09~32 RT16-4 0.16~0.25 JRS1D25P25 CJX2-09~32 RT16-4 0.25~0.4 JRS1D25P4 CJX2-09~32 RT16-4 0.4~0.63 JRS1D25P63 CJX2-09~32 RT16-4 0.63~1 JRS1D251 CJX2-09~32 RT16-4 1~1.6 JRS1D251P6 CJX2-09~32 RT16-4 1.6~2.5 JRS1D252P5 CJX2-09~32 RT16-6 2.5~4 JRS1D254 CJX2-09~32 RT16-10 4~6 JRS1D256 CJX2-09~32 RT16-16 5.5~8 JRS1D258 CJX2-09~32 RT16-20 7~10 JRS1D2510 CJX2-09~32 RT16-20 9~13 JRS1D2513 CJX2-12~32 RT16-25 12~18 JRS1D2518 CJX2-18~32 RT16-35 17~25 JRS1D2525 CJX2-25~32 RT16-50 23~32 JRS1D3632 CJX2-25~32 RT16-63 30~40 JRS1D3640 CJX2-32 RT16-80 23~32 JRS1D9332 CJX2-40~95 RT16-63 30~40 JRS1D9340 CJX2-40~95 RT16-80 37~50 JRS1D9350 CJX2-50~95 RT16-100 48~65 JRS1D9365 CJX2-50~95 RT16-100 55~70 JRS1D9370 CJX2-65~95 RT16-125 63~80 JRS1D9380 CJX2-80~95 RT16-125 80~93 JRS1D9393 CJX2-95 RT16-160 Motor Control & Protection Frame size rated current(A) 36 93 112 JRS1D Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Technical Data Temperature compensation -5℃~+40℃ Trip class 10A JRS1D-25, 36 10 JRS1D-93 660V Structure characteristics Overload protection Yes Phase-failure protection Yes Manual reset Yes Automatic reset Yes Stop button Yes Test button Yes Trip direction Yes Tolerance on slope in any direction ±5° Auxiliary circuit Utilization category AC-15 Rated frequency Hz 50 50 50 Rated insulation voltage Ui V 500 500 500 Rated operational voltage Ue V 220 380 220 Rated operational current Ie A Motor Control & Protection Rated insulation voltage Ui V DC-13 1.64 0.95 0.15 Conventional free air thermal current I th A NO 5 5 5 NC 5 5 5 113 JRS1D Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Accessories Thermal Overload Relay Reference JRS1D-25 JRS1D25J JRS1D-36 JRS1D36J JRS1D-93 JRS1D93J Trip Characteristic Sequence Multiples of setting current Trip time Initial condition Ambient temperature >2h From cold state +20℃ <2h From hot state(immediately following sequence 1 test) Trip class Trip class 10 10A Limits of operation of relays when energized on all poles 1 Motor Control & Protection 2 1.05 >2h 1.2 <2h 3 1.5 <2min <4min From hot state(immediately following sequence 1 test) 4 7.2 2s< Tp≤10s 4s<Tp≤10s From cold state +20℃ >2h From cold state +20℃ <2h From hot state(immediately following sequence 1 test) Limits of operation when energized on two poles Any two The thirdpoles pole 1 2 114 1.0 1.15 0.9 0 >2h <2h JRS1D Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Work Conditions Ambient temperature: -5℃~+40℃, daily average temperature ≤35℃ Altitude: ≤2000m Humidity:The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3 Installation Conditions �c �c Installation Type: Ⅲ Installation position: Unobvious shake and impact shock is necessary. Vertically �cmounting. Tolerance on slope in any direction shall not exceed 5° 5° 5° 360° Motor Control & Protection �c Wire Connection Picture FU-Fuse KM-Contactor FR-Relay SB1-Stop Button SB2-Start Button 115 JRS1D Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Overall Dimensions Unit: mm JRS1D-25 / Z JRS1D-36 / Z Motor Control & Protection JRS1D-93 / Z 116 CJX2-F AC Contactor Standard: IEC 60947-4-1 Function CJX2-F AC contactors provide: □ Remote make & break of circuits □ Frequent start and stop of motors Order Information Motor P(kW) 380V Rated current (A) Reference 55 115 CJX2F115* 75 150 CJX2F150* 90 185 CJX2F185* 110 225 CJX2F225* 132 265 CJX2F265* 160 330 CJX2F330* 200 400 CJX2F400* 250 500 CJX2F500* 335 630 CJX2F630* CJX2-F 9 10 Motor Control & Protection Reference Description * Coil Frequency Coil Voltage Auxiliary contact Rate current Model Coil voltage code coil voltage 36V 110V 220V 380V 400V * C F M Q V Coil frequency code coil frequency · 50Hz 5 60Hz 6 117 CJX2-F AC Contactor Standard: IEC 60947-4-1 Technical Data Model CJX2-F115 CJX2-F150 CJX2-F185 CJX2-F225 CJX2-F265 CJX2-F330 CJX2-F400 CJX2-F500 CJX2-F630 Main circuit characteristics Rated operational voltage V 1000 Rated insulation voltage V 380,660 Rated conventional thermal current A 200 200 275 275 315 380 450 630 800 Rated operational 380V, AC-3 A 115 150 185 225 265 330 400 500 630 current 380V, AC-4 A 52 60 79 85 105 117 138 147 188 660V, AC-3 A 86 108 118 137 170 235 303 353 462 660V, AC-4 A 49 61 69 82 98 118 135 145 170 Power of controlled 380V, AC-3 kW 55 75 90 110 132 160 200 250 335 3-phase cage motor 380V, AC-4 kW 25 30 40 45 55 63 72 80 100 660V, AC-3 kW 80 100 110 129 160 220 280 335 450 660V, AC-4 kW 45 55 63 75 90 110 129 140 160 Mechanical durabilities ×104 cycles 1000 1000 600 600 600 600 600 600 600 Electric durabilities ×104 operations 120 120 100 100 80 80 80 80 80 AC-3 cycles/h 600 600 600 600 600 600 300 300 300 AC-4 cycles/h 120 120 120 120 120 120 120 120 120 Operating rate Motor Control & Protection Matched Fuse Cable cooper RT16-250 RT16-355 RT16-425 RT16-500 RT16-630 RT16-800 RT16-800 RT17-1000 RT17-1250 number of Piece 2 connection conductor cross section mm cooper bar number of Piece dimension 1 1 1 1 1 1 2 2 2 95 95 150 150 185 240 150 185 240 / / / / / / 2 2 2 / / / / / / 30×5 40×5 50×5 Coil Rated voltage power control(Us) V AC36,110,220,380,400 Operational voltage V 85%~110%Us Drop-out voltage V 20%~75%Us Inrush VA 550 550 800 800 1200 1200 1200 1250 1650 Sealed VA 45 45 55 55 13 13 20 24 22 Heat dissipation W 16 16 24 24 12 12 14 18 20 Rated conventional thermal current A 10 Auxliary contact Rated operational AC V 380 voltage DC V 220 Rated control capacity AC-15 VA 360 DC-13 W 33 118 CJX2-F AC Contactor Standard: IEC 60947-4-1 CJX2-F Contactor Accessories Top of auxiliary contact Air delay head Thermal overload relays Motor Control & Protection Contactor 115 Top of auxiliary contact Air delay head Thermal overload relays 150 185 225 265 330 400 500 630 2 Poles:F411,F402,F420 4 Poles: F404,F413,F422,F431,F440 Making time-delay : SK420,SK422,SK424 Breaking time-delay : SK430,SK432,SK434 JRS2-180 55-88A ... 150-180A JRS2-400 80-125A ... 250-400A JRS2-630 320-500A 400-630A 119 CJX2-F AC Contactor Standard: IEC 60947-4-1 Accessories F4 Top of auxiliary contact Pole 2P 4P Contact Wiring diagram Reference Motor Control & Protection NO NC 1 1 F411 0 2 F402 2 0 F420 0 4 F404 1 3 F413 2 2 F422 3 1 F431 4 0 F440 SK4 Air delay head Delay Type Making timedelay Breaking time-delay 120 Wiring diagram Delay Range Reference 0.1-3S SK420 0.1-30S SK422 10-180S SK424 0.1-3S SK430 0.1-30S SK432 10-180S SK434 CJX2-F AC Contactor Standard: IEC 60947-4-1 Working Conditions Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures ■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and shock and vibration place ■ ■ Install Location Motor Control & Protection 121 CJX2-F AC Contactor Standard: IEC 60947-4-1 Overall Dimensions Unit: mm CJX2-F115~330 CJX2-F400~500 Motor Control & Protection CJX2-F630 Model Amax Bmax Cmax P S F M H L X1 X1 Ga Ha (200~500v) (600~1000v) 122 CJX2-F115 167 163 172 37 20 M6 131 147 124 107 10 15 80 110~1120 CJX2-F150 167 171 172 40 20 M8 131 150 124 107 10 15 80 110~1120 CJX2-F185 171 174 183 40 20 M8 131 154 127 103.5 10 15 80 110~1120 CJX2-F225 171 197 183 48 25 M10 131 172 127 103.5 10 15 80 110~1120 CJX2-F265 202 203 215 48 25 M10 147 178 147 141 10 15 96 110~1120 CJX2-F330 213 206 220 48 25 M10 147 181 158 145 10 15 96 110~1120 CJX2-F400 213 206 220 48 25 M10 146 181 158 145 15 20 80 170~1180 CJX2-F500 233 238 233 55 30 M10 150 208 172 146 15 20 80 170~1180 CJX2-F630 309 304 256 80 40 M12 181 264 202 155 20 30 180 170~1180 JRS2 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Function JRS2 relay provide: □ Protect motor and circuit □ Possess overload and phase failure protection functions. Order Information Reference Description JRS2 12P5 P16 F:Installed independently Setting current Rated current Model Current setting(A) Reference Recommended fuse 180 55~88 JRS218088F RT16 -125 63~90 JRS218090F RT16 -125 80~110 JRS2180110F RT16 -200 90~120 JRS2180120F RT16 -200 110~135 JRS2180135F RT16 -200 120~150 JRS2180150F RT16 -200 135~160 JRS2180160F RT16 -250 150~180 JRS2180180F RT16 -250 80~125 JRS2400125F RT16 -200 125~200 JRS2400200F RT16 -400 160~250 JRS2400250F RT16 -400 200~320 JRS2400320F RT16 -500 250~400 JRS2400400F RT16 -500 320~500 JRS2630500F RT16 -630 400~630 JRS2630630F RT16 -630 400 630 Motor Control & Protection Frame size rated current( A ) 123 JRS2 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Technical Data Temperature compensation -5℃~+40℃ Trip class 10A JRS2-180 10 JRS2-400, 630 Rated insulation voltage Ui V 660V Structure characteristics Motor Control & Protection Overload protection Yes Phase-failure protection Yes Manual reset Yes Automatic reset Yes Stop button Yes Test button Yes Trip direction Yes Tolerance on slope in any direction ±5° Auxiliary circuit 124 DC-13 Utilization category AC-15 Rated frequency Hz 50 50 50 Rated insulation voltage Ui V 380 380 500 Rated operational voltage Ue V 220 380 220 Rated operational current Ie A 1.64 0.95 0.16 Conventional free NO 5 5 5 NC 5 5 5 JRS2 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Trip Characteristic Multiples of Sequence setting current Trip time Initial condition Trip class Trip 10A class 10 Ambient temperature Limits of operation of relays when energized on all poles 1 1.05 >2h >2h From cold state +20℃ 2 1.2 <2h <2h From hot state(immediately following sequence 1 test) 3 1.5 <2min <4min From hot state(immediately following sequence 1 test) 4 7.2 2s< Tp≤10s 4s< Tp≤10s From cold state +20℃ +20℃ Motor Control & Protection Limits of operation when energized on two poles Any two The thirdpoles pole 1 1.0 0.9 >2h >2h From cold state 2 1.15 0 <2h <2h From hot state(immediately following sequence 1 test) 125 JRS2 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Work Conditions Ambient temperature: -5℃~+40℃, daily average temperature ≤35℃ Altitude: ≤2000m Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3 Installation Conditions Installation Type: Ⅲ Installation position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 5° 5° 5° Motor Control & Protection 360° Wire Connection Picture FU-Fuse KM-Contactor FR-Relay SB1-Stop Button SB2-Start Button 126 JRS2 Thermal Overload Relay Standard: IEC 60947-4-1 IEC 60947-5-1 Overall Dimensions JRS2-180/F ■ JRS2-400~630/F Motor Control & Protection ■ 25x4 50 10.5 70 146 171 50 Unit: mm 127 CDC9 Switching Capacitor Contactor Standard: IEC 60947-4-1 IEC 60947-5-1 Function CDC9 switching capacitor contactors provide: □ Switch three-phase unipolar or multipolar capacitor group,to improve their power factor □ Reduce the current closing of the impact of capacitor Order Information Auxiliary contact Rated current(A) 25 32 43 Motor Control & Protection 63 95 Reference NO NC 1 1 CDC92511*· 2 0 CDC92520*· 0 2 CDC92502*· 1 1 CDC93211*· 2 0 CDC93220*· 0 2 CDC93202*· 1 1 CDC94311*· 2 0 CDC94320*· 0 2 CDC94302*· 1 2 CDC96312*· 2 1 CDC96321*· 1 2 CDC99512*· 2 1 CDC99521*· Reference Description CDC9 9 10 * · Coil Frequency Coil Voltage Auxiliary contact Rate current Model Coil voltage code coil voltage * 36V 110V 127V 220V 380V 400V C F S M Q V Coil frequency code coil frequency · 128 50Hz 5 60Hz 6 CDC9 Switching Capacitor Contactor Standard: IEC 60947-4-1 IEC 60947-5-1 Technical Data Model CDC9-25 CDC9-32 CDC9-43 CDC9-63 CDC9-95 Main circuit Rated operational voltage V 380 Rated insulation voltage V 500 Controlled capacitor rate capacity 380V, AC-6b A 17 23 29 43 63 Controlled capacitor rate capacity 220V, AC-6b Kvar 6 9 10 15 22.5 380V, AC-6b Kvar 12 18 20 30 45 A 25 32 43 63 95 Rate conventional thermal current Control inrush current capacity ≤20ln Mechanical life ×104 operations 100 Electric life 380V, AC-6b ×104 operations 10 Operating frequency 380V, AC-6b operations/h 300 mm2 4 Cable connection cross section 400 120 of copper conductor Coil V AC36,110,127,220,380,400 Operational voltage V 85%~110%Us Drop-out voltage V 20%~75%Us A 10 Motor Control & Protection Coil voltage(Us) Auxiliary contact Rate conventional thermal current Minimum load can be connected 6V×10mA 129 CDC9 Switching Capacitor Contactor Standard: IEC 60947-4-1 IEC 60947-5-1 Working Conditions Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures ■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and shock and vibration place ■ ■ Altitude: Install Location Motor Control & Protection 130 CDCK8 Air Condition Contactor Standard: IEC 60947-4-1 IEC 60947-5-1 Function CDCK8 air condition contactor provide: □ Remote make & break of circuits □ Frequent start and stop of motors Order Information Rated current(A) Pole 25 1P 32 Auxiliary contact 1P Reference NO NC 0 1 CDCK825101*· 0 0 CDCK825100*· 0 1 CDCK832101*· 0 0 CDCK832100*· 45 1P 0 0 CDCK845100*· 25 2P 0 0 CDCK825200*· 32 2P 0 0 CDCK832200*· Motor Control & Protection Reference Description CDCK8 25 1 10 * · Coil Frequency Coil Voltage Auxiliary contact Pole Rate current Model Coil voltage code Coil voltage * 36V 110V 220V C F M 50Hz 5 60Hz 6 Coil frequency code Coil frequency · 131 CDCK8 Air Condition Contactor Standard: IEC 60947-4-1 IEC 60947-5-1 Technical Data Model CDCK8-25 CDCK8-32 CDCK8-45 Main circuit characteristics Rate insulation voltage V 690 Rated voltage shock tolerance kV 4 Rated operational voltage V 220 A 32 40 50 A 25 32 45 kW(Hp) 2.5(3) 3.2(4) 4.5(5) x104 operations 100 Rate conventional thermal current Rate operational current Power of controlled AC-8b 220V, AC-8b single-phase motor Mechanical life Electric life AC-8b x104 operations 8 Operating frequency AC-8b operations/h 300 Short time withstand current 10S A 8le Matched fuse Motor Control & Protection RT16-40 RT16-50 RT16-63 Connecting line mm2 6 10 16 Coil Coil voltage(Us) V AC36,110,220 V 70%~110%Us V 20%~60%Us VA 36 VA 4 Rate conventional thermal current A 5 Rated operational voltage V V 220 VA 100 Operational voltage Drop-out voltage Inrush Sealed Auxiliary contact Control capability 132 AC-1 CDCK8 Air Condition Contactor Standard: IEC 60947-4-1 IEC 60947-5-1 Working Conditions Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures ■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and shock and vibration place ■ ■ Install Location Motor Control & Protection 133 CDCK8 Air Condition Contactor Standard: IEC 60947-4-1 IEC 60947-5-1 Overall Dimensions Unit:mm Motor Control & Protection 134 Product type Pole Amax Bmax CDCK8-25,32 1P 70 62 CDCK8-25/01,32/01 1P 70 69 CDCK8-25,32 2P 86 61.5 CDCK8-45 1P 85 67 CDZ17 Contactor Relay Standard: IEC 60947-5-1 Function CDZ17 contactor relays provide: □ Remote make & break of circuits □ Start, stop and control of small capacity motors □ Boost signals, interlock electric, transfer signals or control various kinds of magnetic coils Order Information Contact blocks Rated current(A) 6 9 9 NC 1 3 CDZ17613* 2 2 CDZ17622* 3 1 CDZ17631* 4 0 CDZ17640* 0 4 CDZ17604* 1 3 CDZ17913* 2 2 CDZ17922* 3 1 CDZ17931* 4 0 CDZ17940* 0 4 CDZ17904* 4 4 CDZ17644* 5 3 CDZ17653* 6 2 CDZ17662* 7 1 CDZ17671* 8 0 CDZ17680* 4 4 CDZ17944* 5 3 CDZ17953* 6 2 CDZ17962* 7 1 CDZ17971* 8 0 CDZ17980* Motor Control & Protection 6 Reference NO Coil voltage code Coil voltage 24V 36V 48V 110V 220V 380V 400V 440V * B C E F M Q V X Coil power supply Coil power supply DC AC Z Default Reference Description CDZ17 9 13 M Default: AC Z:DC Coil voltage Contact blocks Rated current Model 135 CDZ17 Contactor Relay Standard: IEC 60947-5-1 Technical Data 6A Model 9A 24 48 110 220 440 24 48 110 220 440 4 2.5 1 0.5 0.2 6 3.5 1.5 0.6 0.3 36 110 220/230 380/400 690 36 110 220/230 380/400 Rated operational current A 6 6 6 9 9 9 Contact assemble Single Rated operational voltage V DC-13 Rated operational voltage A Rated operational current V AC-15 4 1.5 Double NO NC NO NC 1 3 4 4 2 2 5 3 3 1 6 2 4 0 7 1 0 4 8 0 Motor Control & Protection Rated insulation voltage V 690 Rated impulse withstand voltage V 8000 Rated conventional thermal current A 16 Minimum load can be connected 12V Electric durabilities(x104 operations) 100 Mechanical durabilities(x104 cycles) 1000 Operating rate(cycles/h) 3000(AC) Matched Fuse RT16-20 Cross Section of Cable mm2 (maximum) 2.5(X2) 10mA 1200(DC) Coil Coil voltage(Us) V AC36, 110, 220, 380,400; DC24, 48, 110, 220, 440 Operational voltage V 80%~110%Us Drop-out voltage V 20%~75%Us(AC) Inrush VA 70(AC) Sealed VA 8(AC) Heat dissipation W 2.8(AC) Weight 0.32(Single,AC) 0.36(double,AC) 0.52(Single,DC) 0.56(double,DC) 136 Kg 10%~75%Us(DC) 7(DC) 6.5(DC) 6 690 3 CDZ17 Contactor Relay Standard: IEC 60947-5-1 Work Conditions ■ Ambient temperature: -15℃~+50℃, daily average temperature ≤35℃ ≤2000m ■ Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +50℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change ■ Pollution class: 3 ■ Altitude: Installation Conditions ■ Installation Type: Ⅲ position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 5° ■ Installation 25° 25° Motor Control & Protection 137 CDZ17 Contactor Relay Standard: IEC 60947-5-1 Overall Dimensions CDZ17-40, 31, 22, 13, 04 CDZ17-80, 71, 62, 53, 44 Motor Control & Protection CDZ17-40/Z, 31/Z, 22/Z, 13/Z, 04/Z CDZ17-80/Z,71/Z,62/Z,53/Z,44/Z 138 Unit: mm CDZ8 Miniature Relay Function Used to implement the conversion of intermediate control signals and low-power output, In the field of industrial control, used in conjunction with contactors, relays, circuit breakers, etc. Order Information Poles Rated Current LED Voltage Type Reference 2 5A L AC CDZ8052L*1 None AC CDZ8052*1 L DC CDZ8052L*Z1 None DC CDZ8052*Z1 Accessory 3 CDZ8PYF08AXXKH 5A L AC CDZ8053L*1 None AC CDZ8053*1 L DC CDZ8053L*Z1 None DC CDZ8053*Z1 Accessroy 4 CDZ8PYF11AXXKH 3A AC CDZ8034L*1 AC CDZ8034*1 L DC CDZ8034L*Z1 None DC CDZ8034*Z1 Accessory CDZ8PYF14AXXKH Rated voltage code Rated voltage 6V 12V 24V 36V 48V 110V 127V 220V 230V * I J B C E F S M N 139 Motor Control & Protection L None CDZ8 Miniature Relay Technical Data Contact Form 2Z 3Z 4Z Capacity 5A 5A 3A Nominal coil voltage AC 6-220V DC 6-220V Resistance ≤50mΩ Materials Silver Alloy Electrical life expectancy ≥105 times (1800 Ops/h) Mechanical life expectancy ≥107 times (18000 Ops/h) Type Description LED Operating voltage (25℃) DC:≤ 75%Ue, AC:80%Ue Release voltage (25℃) DC:≥10%Ue, AC:30%Ue Maximum voltage (25℃) 110%Ue Coil consumption DC(W) 0.9 1.2 AC(VA) Motor Control & Protection Operating time (Rated voltage) ≤20ms Release time (Rated voltage) ≤20ms Dielectric Strength Between contacts 1300VAC/1min Between 1500VAC/1min contacts(different pole) Between Contact and coil 1800VAC/1min Ambient temperature -25~+55℃ Humidity 35%~85%RH Atmospheric pressure 86~106KPa Shock resistance 10G(Sine half-wave pulse:11ms) Vibration resistance 10~55Hz Double amplitude:1.0mm Install model Plug-in terminals Weight 35g Coil Specifications (25℃) 140 Rated voltage V.DC 6 12 24 36 Coil resistanceΩ(±10%) 40 160 600 1440 2600 11000 42000 Rated voltage V.AC 6 12 24 36 48 110 127 220 Coil resistance Ω(±10%) 11.5 40 160 370 600 3750 4100 14000 48 110 220 CDZ8 Miniature Relay Accessories Matched relay socket Outline dimensions(mm) CDZ8PYF08AXXKH 3Z CDZ8PYF11AXXKH 4Z CDZ8PYF14AXXKH Wiring diagram Motor Control & Protection 2Z Mount dimensions 141 CDZ8 Miniature Relay Overall Dimensions Unit: mm CDZ8-2Z ■ CDZ8-3Z ■ CDZ8-4Z Motor Control & Protection ■ 142 JSZ3 Series Electronic Time Relay Standard: IEC 60947-5-1 Function JSZ3 Series eletroms time relay provide Rated AC frequency 50Hz & controlling voltage 400V or below. Rated DC control power voltage 220V or below. Be used as time-control component in the automatic controlling circuit, according to the scheduled time turn on or off the circuit. Order Information Relay mode Rated working voltage Relay after 120V power-on 240V Reference A: 0.05-0.5s/5s/30s/3M JSZ3AA120 B: 0.1-1s/10s/60s/6M JSZ3AB120 C: 0.5-5s/50s/5M/30M JSZ3AC120 D: 1-10s/100s/10M/60M JSZ3AD120 E: 6s-60s/10M/60M/6h JSZ3AE120 F: 0.2M-2M/20M/2h/12h JSZ3AF120 G: 0.4M-4M/40M/4h/24h JSZ3AG120 A: 0.05-0.5s/5s/30s/3M JSZ3AA240 B: 0.1-1s/10s/60s/6M JSZ3AB240 C: 0.5-5s/50s/5M/30M JSZ3AC240 D: 1-10s/100s/10M/60M JSZ3AD240 E: 6s-60s/10M/60M/6h JSZ3AE240 F: 0.2M-2M/20M/2h/12h JSZ3AF240 G: 0.4M-4M/40M/4h/24h JSZ3AG240 A: 0.05-0.5s/5s/30s/3M JSZ3AA400 B: 0.1-1s/10s/60s/6M JSZ3AB400 C: 0.5-5s/50s/5M/30M JSZ3AC400 D: 1-10s/100s/10M/60M JSZ3AD400 E: 6s-60s/10M/60M/6h JSZ3AE400 F: 0.2M-2M/20M/2h/12h JSZ3AF400 G: 0.4M-4M/40M/4h/24h JSZ3AG400 Motor Control & Protection 400V Relay time 143 JSZ3 Series Electronic Time Relay Standard: IEC 60947-5-1 Order Information Relay mode Relay after Rated working voltage 120V power-off 240V Motor Control & Protection 400V 144 Relay time Reference 1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s 5S: 0.5s-5s 6S: 0.6s-6s 10S: 1s-10s 20S: 2s-20s 30S: 3s-30s 60S: 6s-60s 100S: 10s-100s 180S: 18s-180s 4M: 0.4min-4min 5M: 0.5min-5min 6M: 0.6min-6min 10M: 1min-10min 20M: 2min-20min 30M: 3min-30min 1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s 5S: 0.5s-5s 6S: 0.6s-6s 10S: 1s-10s 20S: 2s-20s 30S: 3s-30s 60S: 6s-60s 100S: 10s-100s 180S: 18s-180s 4M: 0.4min-4min 5M: 0.5min-5min 6M: 0.6min-6min 10M: 1min-10min 20M: 2min-20min 30M: 3min-30min 1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s 5S: 0.5s-5s 6S: 0.6s-6s 10S: 1s-10s 20S: 2s-20s 30S: 3s-30s 60S: 6s-60s 100S: 10s-100s 180S: 18s-180s 4M: 0.4min-4min 5M: 0.5min-5min 6M: 0.6min-6min 10M: 1min-10min 20M: 2min-20min 30M: 3min-30min JSZ3F1S120 JSZ3F2S120 JSZ3F3S120 JSZ3F5S120 JSZ3F6S120 JSZ3F10S120 JSZ3F20S120 JSZ3F30S120 JSZ3F60S120 JSZ3F100S120 JSZ3F180S120 JSZ3F4M120 JSZ3F5M120 JSZ3F6M120 JSZ3F10M120 JSZ3F20M120 JSZ3F30M120 JSZ3F1S240 JSZ3F2S240 JSZ3F3S240 JSZ3F5S240 JSZ3F6S240 JSZ3F10S240 JSZ3F20S240 JSZ3F30S240 JSZ3F60S240 JSZ3F100S240 JSZ3F180S240 JSZ3F4M240 JSZ3F5M240 JSZ3F6M240 JSZ3F10M240 JSZ3F20M240 JSZ3F30M240 JSZ3F1S400 JSZ3F2S400 JSZ3F3S400 JSZ3F5S400 JSZ3F6S400 JSZ3F10S400 JSZ3F20S400 JSZ3F30S400 JSZ3F60S400 JSZ3F100S400 JSZ3F180S400 JSZ3F4M400 JSZ3F5M400 JSZ3F6M400 JSZ3F10M400 JSZ3F20M400 JSZ3F30M400 JSZ3 Series Electronic Time Relay Standard: IEC 60947-5-1 Technical Data Condition AC-15 400V/1.95A; 240V/1.5A; 120V/3.0A DC-13 250V/0.27A; 125V/0.55A Repetitive error ≤5% Rated themal current 5A Mechanical life ≥1×106 times Electric life ≥1×105 times Power loss ≤3W Working mode A: Relay after power-on Reset mode A:Power-off reset F:External device reset Contactor endurance A:5A (Resistive) F:1A(Resistive) Relay time JSZ3A: 0.05s-0.5s/5s/30s/3M,0.1s-1s/10s/60s/6M 0.5s-5s/50s/5M/30M,1s-10s/100s/10M/60M F:Relay after power-off 6s-60s/10M/60M/6h,0.2M-2M/20M/2h/12h 0.4M-4M/40M/4h/24h JSZ3F: 0.1s-1s,0.2s-2s,0.3s-3s,0.5s-5s,0.6s-6s,1s10s,2s-20s,3s-30s,6s-60s,10s-100s,10s-120s,10s180s,0.4M-4M,0.5M-5M,0.6M-6M,1M-10M,2MTemp. -5℃~+40℃ Install mode Install mounted, Din rail mounted, Panel mounted Motor Control & Protection 20M,3M-30M Overall Dimensions Unit: mm ELECTRIC 145 XJ9 Phase Failure And Sequence Protection Relay Standard: IEC 60947-5-1 Function XJ9 phace failare and sequence proctection relay provide: Rated AC frequency of 50Hz, rated control supply voltage AC 400V. Phase failure and phase sequence protector. Order Information Function Voltage Reference Phase failure sequency protection 380V 400V XJ9380 XJ9400 Technical Data Standard IEC 60947-5-1 Overvoltage protection 400-480V(adjustable), Reaction time: 1.5-4S(adjustable) Undervoltage protection 320-400V(adjustabe). Reaction time: 2-9S(adjustable) Phase failure & phase Reaction time ≤2S Wrong protect time Motor Control & Protection Contactor mode 1 NO,1NC Contactor endurance 5A Resistive Power voltage AC 400V Mechanical lifetime ≥1×106 times Electrical lifetime ≥1×105 times Power loss ≤1W Contactor capacity AC400V×3 Overall Dimensions Unit: mm XJ9 35.5 83Max 91Max 24Max 146 Contents Power Energy Management Current Transformer 148-150 LMK Series 148 Current Transformer 151-163 Meter DDS607 Single-phase Electronic Watt-hour Meter 152 DTS607 Three-phase Four-Wire Electronic Watt-hour Meter 154 DSS607 Three-phase Three-Wire Electronic Watt-hour Meter 157 72 Series Panel Meter 160 96 Series Panel Meter 162 164-167 1~5 KG316T Digital Time Switch 165 KG316TD Digital Time Switch 166 KG816 Series Digital Time Switch 167 Voltage Stabilizer 168-174 TND Single-phase Full Automatic AC Voltage Stabilizer 169 SJW Three-phase Full Automatic AC Voltage Stabilizer 171 SBW Three-phase Compensation AC Voltage Stabilizer 173 Management Power Energy Digital Time Switch 147 LMK Series Current Transformer Standard: IEC 60044-1 Function LMK Series Current Transformer provide: Measuring and transforming the high current to low current. Order Information Model LMK-0.66-20 LMK-0.66-30 LMK-0.66-40 LMK-0.66-50 LMK-0.66-60 Power Energy Management LMK-0.66-80 LMK-0.66-100 LMK-0.66-120 148 Current ratio (A) 30/5 50/5 75/5 100/5 100/5 150/5 200/5 100/5 200/5 250/5 300/5 250/5 300/5 400/5 500/5 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5 Class: 0.5 Maximum Voltage: 0.66KV Rated Load (VA) 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75 Bar (mm) 30×10 30×10 30×10 40×10 40×10 40×10 40×10 50×10 50×10 50×10 50×10 50×10 50×10 50×10 60×20 60×20 60×20 60×20 60×20 60×20 60×20 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 Diameter (mm) 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 35 35 35 35 35 35 35 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Number of Turns Reference through the core 5 3 2 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LMKP63020 LMKP65020 LMKP67520 LMKP610020 LMKP610020 LMKP615020 LMKP620020 LMKP610030 LMKP620030 LMKP625030 LMKP630030 LMKP625040 LMKP630040 LMKP640040 LMKP650040 LMKP630050 LMKP640050 LMKP650050 LMKP660050 LMKP675050 LMKP680050 LMKP6100050 LMKP650060 LMKP660060 LMKP675060 LMKP680060 LMKP6100060 LMKP6120060 LMKP6150060 LMKP660080 LMKP675080 LMKP680080 LMKP6100080 LMKP6120080 LMKP6150080 LMKP6200080 LMKP6250080 LMKP6600100 LMKP6750100 LMKP6800100 LMKP61000100 LMKP61200100 LMKP61500100 LMKP62000100 LMKP62500100 LMKP63000100 LMKP61500120 LMKP62000120 LMKP62500120 LMKP63000120 LMKP64000120 LMKP65000120 LMK Series Current Transformer Standard: IEC 60044-1 Order Information Class: 1 Maximum Voltage: 0.66KV Model Current ratio Rated Load (VA) (A) Bar (mm) LMK-0.66-20 30/5 50/5 75/5 100/5 150/5 200/5 100/5 200/5 250/5 300/5 250/5 300/5 400/5 500/5 600/5 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 1200/5 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5 20 20 20 20 20 20 20 20 30×10 20 30×10 20 30×10 30 40×10 30 40×10 30 40×10 30 40×10 30 40×10 35 50×10 35 50×10 35 50×10 35 50×10 35 50×10 35 50×10 35 50×10 35 60×20 45 60×20 45 60×20 45 60×20 45 60×20 45 60×20 45 60×20 45 60×20 45 60×20 80×10 or 60×30 50 80×10 or 60×30 50 80×10 or 60×30 50 80×10 or 60×30 50 80×10 or 60×30 50 80×10 or 60×30 50 80×10 or 60×30 50 80×10 or 60×30 50 100×10 or 80×30 60 100×10 or 80×30 60 100×10 or 80×30 60 100×10 or 80×30 60 100×10 or 80×30 60 100×10 or 80×30 60 100×10 or 80×30 60 100×10 or 80×30 60 100×10 or 80×30 60 120×10 or 80×30 60 120×10 or 80×30 60 120×10 or 80×30 60 120×10 or 80×30 60 120×10 or 80×30 60 120×10 or 80×30 60 LMK-0.66-30 LMK-0.66-40 LMK-0.66-50 LMK-0.66-60 LMK-0.66-100 LMK-0.66-120 5 3 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LMKP6P13020 LMKP6P15020 LMKP6P17520 LMKP6P110020 LMKP6P115020 LMKP6P120020 LMKP6P110030 LMKP6P120030 LMKP6P125030 LMKP6P130030 LMKP6P125040 LMKP6P130040 LMKP6P140040 LMKP6P150040 LMKP6P160040 LMKP6P130050 LMKP6P140050 LMKP6P150050 LMKP6P160050 LMKP6P175050 LMKP6P180050 LMKP6P1100050 LMKP6P1120050 LMKP6P150060 LMKP6P160060 LMKP6P175060 LMKP6P180060 LMKP6P1100060 LMKP6P1120060 LMKP6P1150060 LMKP6P1200060 LMKP6P160080 LMKP6P175080 LMKP6P180080 LMKP6P1100080 LMKP6P1120080 LMKP6P1150080 LMKP6P1200080 LMKP6P1250080 LMKP6P1600100 LMKP6P1750100 LMKP6P1800100 LMKP6P11000100 LMKP6P11200100 LMKP6P11500100 LMKP6P12000100 LMKP6P12500100 LMKP6P13000100 LMKP6P11500120 LMKP6P12000120 LMKP6P12500120 LMKP6P13000120 LMKP6P14000120 LMKP6P15000120 149 Management Power Energy LMK-0.66-80 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75 Diameter Number of Turns Reference through the core (mm) LMK Series Current Transformer Standard: IEC 60044-1 Technical Data Primary current: 100A-5000A Secondary approval: 5A, 1A Maximum voltage: 0.66kV Class: 0.5, 1.0, 3.0 Short time thermal current: Ith=100Ih Rated security coefficient: FS<5 Standard: IEC 60044-1 Overall Dimensions Unit: mm Power Energy Management 150 Model H W D LMK-0.66-20 87 68 42 LMK-0.66-30 79 60 37 LMK-0.66-40 99 75 40 LMK-0.66-50 99 82 40 LMK-0.66-60 126 102 40 LMK-0.66-80 118 125 40 LMK-0.66-100 136 170 40 LMK-0.66-120 136 190 41 Meter Overview Watt-hour Meter Meter Single-phase DDS607 152 Type: Single-phase Specification 1.5(6)A, 3(6)A 2.5(10)A, 5(20)A 5(30)A, 10(40)A 15(60)A, 20(80)A 30(100)A Three-phase DTS607 154 DSS607 Type: Three-phase Three-wire Specification Specification 1.5(6)A, 3(6)A 2.5(10)A, 5(20)A 5(30)A, 10(40)A 15(60)A, 20(80)A 30(100)A 1.5(6)A, 3(6)A 5(20)A, 10(40)A 15(60)A. 20(80)A 30(100)A Management Power Energy Type: Three-phase Four-wire 157 Panel Meter 72 Series 160 96 Series Type: Ammeter Voltmeter Frequency meter Type: Ammeter Voltmeter Frequency meter Specification 72x72mm Specification 96x96mm 162 151 DDS607 Single-phase Electronic Watt-hour Meter Standard:IEC 620531-21 Function DDS607 single-phase watt-hour meter provide: Measuring the active energy in the single-phase AC power network with frequency of 50Hz or 60Hz. Measuring the active energy for enterprises, transformer substation or power substation. And be used as the automation meter in power transmission and distribution. Order Informationn Power Energy Management Function Description Current specification Reference Type A (Import chip) 1.5(6)A DDS607N16M4A Type A (Import chip) 2.5(10)A DDS607N110M4A Type A (Import chip) 5(20)A DDS607N120M4A Type A (Import chip) 5(30)A DDS607N130M6A Type A (Import chip) 10(40)A DDS607N140M4A Type A (Import chip) 15(60)A DDS607N160M4A Type A (Import chip) 20(80)A DDS607N180M4A Type A (Import chip) 30(100)A DDS607N1100M3A Type C (Domestic chip) 1.5(6)A DDS607N26M4C Type C (Domestic chip) 2.5(10)A DDS607N210M4C Type C (Domestic chip) 5(20)A DDS607N220M4C Type C (Domestic chip) 5(30)A DDS607N230M6C Type C (Domestic chip) 10(40)A DDS607N240M4C Type C (Domestic chip) 15(60)A DDS607N260M4C Type C (Domestic chip) 20(80)A DDS607N280M4C Type C (Domestic chip) 30(100)A DDS607N2100M3C LCD without 485 communications 1.5(6)A DDS607N16M4CD LCD without 485 communications 2.5(10)A DDS607N110M4CD LCD without 485 communications 5(20)A DDS607N120M4CD LCD without 485 communications 5(30)A DDS607N130M6CD LCD without 485 communications 10(40)A DDS607N140M4CD LCD without 485 communications 15(60)A DDS607N160M4CD LCD without 485 communications 20(80)A DDS607N180M4CD LCD with 485 communications 1.5(6)A DDS607N16M4CD485 LCD with 485 communications 5(20)A DDS607N120M4CD485 LCD with 485 communications 10(40)A DDS607N140M4CD485 LCD with 485 communications 15(60)A DDS607N160M4CD485 LCD with 485 communications and infrared communications 1.5(6)A DDS607N116M4CD485I LCD with 485 communications and infrared communications 2.5(10)A DDS607N110M4CD485I LCD with 485 communications and infrared communications 5(20)A DDS607N120M4CD485I LCD with 485 communications and infrared communications 5(30)A DDS607N130M6CD485I LCD with 485 communications and infrared communications 10(40)A DDS607N140M4CD485I LCD with 485 communications and infrared communications 15(60)A DDS607N160M4CD485I LCD with 485 communications and infrared communications 20(80)A DDS607N180M4CD485I LCD with 485 communications and infrared communications DDS607N1100M3CD485I Note: Users need special specifications can be customized 152 30(100)A DDS607 Single-phase Electronic Watt-hour Meter Standard:IEC 620531-21 Technical Data Standard IEC 620531-21 Certificate KEMA Working voltage(V) 230V Power loss Voltage circuit ≤2W per10VA, Current circuit ≤4VA Optional functions LCD display, Infrared communication, 485 communication Normal working temp. -10℃~+45℃ Limited working temp. -25℃~+55℃ Normal working voltage 0.9~1.1(Ref. voltage) Limited working voltage 0.8~1.15(Ref. voltage) Relative humidity <75% Installation location Should be installed in the height of 1.8m vertically and the angularity≤1° Overall Dimensions Unit: mm Management Power Energy Single-phase Type A,C Meter Single-phase LCD Meter 153 DTS607 Three-phase Four-wire Electronic Watt-hour Meter Standard: IEC 62053-21 Function DTS607 Three Phase four-wire watt-hour meter provide: Measuring the active energy in the three-phase four-wire AC power network at frequency of 50Hz or 60Hz. Measure the active energy of enterprises, transformer substation or power stations, and be used as automation meters of power transmission and distribution network. Order Information Voltage(V) Grade Current(A) Reference 57.7/100 1 1.5(6) DTS607WY16M4 3(6) DTS607WY16M2 230/400 1 1.5(6) DTS607NV16M4 3(6) DTS607NV16M2 5(20) DTS607NV120M4 10(40) DTS607NV120M5 15(60) DTS607NV120M6 20(80) DTS607NV120M7 30(100) DTS607NV120M8 NOTE: “M” expresses the current multiple in the standard codes. Transformer function (H) is merely available for 1.5(6)A and 3(6)A. Power Energy Management 154 DTS607 Three-phase Four-wire Electronic Watt-hour Meter Standard: IEC 62053-21 Technical Data Working voltage 57.7/100V, 230/400V Power loss Voltage circuit≤2W per10VA, Current circuit≤4VA Optional functions LCD display, Infrared communication, 485 communication Normal working temp. -10℃~+45℃ Ultimate working temp. -25℃~+55℃ Normal working voltage 0.9~1.1(Ref. voltage) Ultimate working voltage 0.8~1.15(Ref. voltage) Relative humidity <75% Installation location Should be installed in the height of 1.8m vertically and the angularity≤1°. Wiring Diagram Wiring diagram for 3 x 57.7/100V ≤3 x 3(6)A with voltage transformer ■ Wiring diagram for 3 x 230/400V ≤3 x 3(6)A with current transformer Management Power Energy ■ 155 DTS607 Three-phase Four-wire Electronic Watt-hour Meter Standard: IEC 62053-21 Wiring Diagram ■ Wiring diagram for 3 x 230/400V ≥3 x 2.5(10)A direct pulse ■ pulse pulse Wiring diagram for impulse testing Overall Dimensions Power Energy Management 156 pulse Unit: mm DSS607 Single-phase Electronic Watt-hour Meter Standard: IEC 62053-21 Function DSS607 Single-phase electronic watt-hour meter provides: Measuring the active energy in the three-phase three-wire AC power network at frequency of 50Hz or 60Hz. Measure the active energy of enterprises, transformer substation or power stations, and be used as automation meters of power transmission and distribution network Order Information Voltage(V) Grade Current(A) Reference 100 1 1.5(6) DSS607Y16M4 3(6) DSS607Y16M2 1.5(6) DSS607V16M4 3(6) DSS607V16M2 5(20) DSS607V120M4 10(40) DSS607V140M4 15(60) DSS607V160M4 20(80) DSS607V180M4 30(100) DSS607V1100M3 1 400 NOTE: “M” expresses the current multiple in the standard codes. Transformer function (H) is merely available for 1.5(6)A and 3(6)A. Management Power Energy 157 DSS607 Single-phase Electronic Watt-hour Meter Standard: IEC 62053-21 Technical Data Standard IEC 62053-21 ℃~ ℃ ℃~ ℃ ~ ~ <75% Wiring Diagram Power Energy Management 158 ■ Wiring diagram for 3 x 100V ≤3 x 3(6)A with voltage transformer ■ Wiring diagram for 3 x 400V ≤3 x 3(6)A with current transformer DSS607 Single-phase Electronic Watt-hour Meter Standard: IEC 62053-21 Wiring Diagram ■ Wiring diagram for 3 x 400V ≥3 x 2.5(10)A direct pulse ■ pulse pulse pulse Wiring diagram for impulse testing Overall Dimensions Unit: mm Management Power Energy 159 72 Series Panel Meter Standard: IEC 60051 Function 72 series panel meter provide: 72T applies to measure the current, voltage or frequency in the AC circuit. 72C applies to measure the current or voltage in the DC circuit. Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and other electric-control facilities in the AC transmission circuit system Order Information Accuracy Specification rating Note Shape(mm) Reference Ammeter 1.5 30/5A AC Type 72×72×67.5 72TA30 40/5A External connection 72×72×67.5 72TA40 50/5A transformer 72×72×67.5 72TA50 60/5A 2 times of current 72×72×67.5 72TA60 75/5A overload 72×72×67.5 72TA75 80/5A 72×72×67.5 72TA80 100/5A 72×72×67.5 72TA100 150/5A 72×72×67.5 72TA150 160/5A 72×72×67.5 72TA160 200/5A 72×72×67.5 72TA200 250/5A 72×72×67.5 72TA250 300/5A 72×72×67.5 72TA300 400/5A 72×72×67.5 72TA400 600/5A 72×72×67.5 72TA600 800/5A 72×72×67.5 72TA800 1000/5A 72×72×67.5 72TA1000 1600/5A 72×72×67.5 72TA1600 5000/5A 72×72×67.5 72TA5000 10000/5A 72×72×67.5 72TA10000 72×72×67.5 72TA5A Power Energy Management Type 2.5 Voltmeter 5A AC Type Direct connection 15A AC Type 72×72×67.5 72TA15A 20A Direct connection 72×72×67.5 72TA20A 25A 2 times of current 72×72×67.5 72TA25A 30A overload 72×72×67.5 72TA30A 40A 72×72×67.5 72TA40A 50A 72×72×67.5 72TA50A 60A 72×72×67.5 72TA60A 80A 72×72×67.5 72TA80A 100A 72×72×67.5 72TA100A 1.5 5A DC Type 72×72×67.5 72CA5A 1.5 300V AC Type 72×72×67.5 72TV300V 500V 72×72×67.5 72TV500V 600V 72×72×67.5 72TV600V DC Type 72×72×67.5 72CV5500V 45-55HZ (200V) AC Type 72×72×67.5 72THZ01200V 500V Frequency meter 160 1.0 72 Series Panel Meter Standard: IEC 60051 Technical Data Standard IEC 60051 Dielectric strength test Frequency 50Hz /60Hz Voltage 2000V, duration 1 minute 2 Impact test Response time Max acceleration 147m/s Angular Deflection 90 Temp. Humidity -25℃~+40 (25%~80%)RH No mildew, insects, salt mist, dew in the air, few sands and dusts are permitted. Shall be installed Vertically v Environment : Installation: : 4s 。 Overall Dimensions Management Power Energy 161 96 Series Panel Meter Standard: IEC 60051 Function 96 series panel meter provide: 96T applies to measure the current, voltage or frequency in the AC circuit. 96C applies to measure the current or voltage in the DC circuit. Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and other electric-control facilities in the AC transmission circuit system Order Information Type Ammeter Accuracy Specification rating 1.5 Power Energy Management 2.5 1.5 Voltmeter 1.5 Note Shape(mm) Reference 30/5A AC Type 96×96×67.5 96TA30 40/5A External connection 96×96×67.5 96TA40 50/5A transformer 96×96×67.5 96TA50 60/5A 96×96×67.5 96TA60 75/5A 96×96×67.5 96TA75 80/5A 96×96×67.5 96TA80 100/5A 96×96×67.5 96TA100 150/5A 96×96×67.5 96TA150 160/5A 96×96×67.5 96TA160 200/5A 96×96×67.5 96TA200 250/5A 96×96×67.5 96TA250 300/5A 96×96×67.5 96TA300 400/5A 96×96×67.5 96TA400 600/5A 96×96×67.5 96TA600 800/5A 96×96×67.5 96TA800 1000/5A 96×96×67.5 96TA1000 1600/5A 96×96×67.5 96TA1600 5000/5A 96×96×67.5 96TA5000 10000/5A 96×96×67.5 96TA10000 96×96×67.5 96TA5A 5A AC Type Direct connection 15A AC Type 96×96×67.5 96TA15A 20A Direct connection 96×96×67.5 96TA20A 25A 96×96×67.5 96TA25A 30A 96×96×67.5 96TA30A 40A 96×96×67.5 96TA40A 50A 96×96×67.5 96TA50A 60A 96×96×67.5 96TA60A 80A 96×96×67.5 96TA80A 100A 96×96×67.5 96TA100A DC Type 96×96×67.5 96CA5A AC Type 96×96×67.5 96TV300V 500V 96×96×67.5 96TV500V 600V 96×96×67.5 96TV600V DC Type 96×96×67.5 96CV500 45-55HZ (200V) AC Type 96×96×67.5 96THZ01200V 5A 300V 500V Frequency meter 1.0 162 96 Series Panel Meter Standard: IEC 60051 Technical Data Standard IEC 60051 Dielectric strength test Frequency 50Hz /60Hz Voltage 2000V, duration 1 minute 2 Impact test Max acceleration 147m/s Response time ≤ 4s Angular Deflection 90 Temp. Humidity: -25℃~+40 (25%~80%)RH No mildew, insects, salt mist, dew in the air, few sands and dusts are permitted. v Shall be installed Vertically Environment : Installation: 。 Overall Dimensions Management Power Energy 163 Time Switch Overview KG316T 165 Max.switch times per day:10-on-10-off, 8-on-8-off Reset:Power-off reset KG316TD 166 Max.switch times per day:16-on-16-off Reset:key-button reset KG816A 167 Power Energy Management Max.switch times per day:16-on-16-off Reset:key-button reset KG816B Max.switch times per day:8-on-8-off Reset:key-button reset 164 167 KG316T Series Digital Time Switch Standard: IEC 60947-5-1 KG316T Series Digital Time Switch provide: Rated AC frequency of 50Hz, rated AC control voltage 400V or below. Be used as time control components in automatic control circuit, according to the scheduled time to turn-on or off the circuits. Order Information Output loops Rated control voltage Reference 10-on-10-off (Single output) AC:230V KG316T230 AC:400V KG316T400 AC:230V KG316T2230 AC:400V KG316T2400 8-on-8-off (Double output) Technical Data IEC 60947-5-1 Control time Control power Setting Value range from 1min to168h Operation by daily or weekly AC-15: 240V/3A 400V/1.9A 6kW Rated control voltage 230/400V AC Rated thermal cur. Accuracy Mechanical life 10A y 2 ≥1×106 times Electrical life ≥1×105 times Power loss ≤3W Temp. Display modet -5℃~+40℃ ~ Digital LED display Time-set Mode Digital Keyswitch settingt Battery Inner alkaline battery Install Mode Install mounted, Din rail mounted Using mode Management Power Energy Standard Overall Dimensions Unit: mm Wiring Diagram N OUT PUT LOAD Single output IN L1 OUT L1 OUT L2 SOURCE INPUT SOURCE Function LOAD 1 LOAD 2 Double output 165 KG316TD Series Digital Time Switch Standard: IEC 60947-5-1 Function KG316TD Series Digital Time Switch provide: Rated AC frequency of 50Hz, rated control supply voltage AC 400V or below. Any circuit equipments that need to be turned-on-or-off timely. Order Information Output loops Rated control voltage Reference 16-on-16-off AC:230V KG316TD230 AC:400V KG316TD400 Technical Data Standard IEC 60947-5-1 Control time Control power Setting Value range from 1min to168h Operation by daily or weekly AC-15: 240V/3A 400V/1.9A 6kW Rated control voltage 230/400V AC Rated thermal cu r. Accuracy Mechanical life 10A Electrical life ≥1×105 times Power loss ≤3W Temp. Display modet -5℃~+40℃ Digital LED display Time-set Mode Digital Keyswitch settingt Battery Inner rechangeable battery Install Mode Install mounted, Din rail mounted Using mode ≥1×106 times Power Energy Management Overall Dimensions Unit: mm Management Power Energy Wiring Diagram 166 KG816 Series Digital Time Switch Standard:IEC 60947-5-1 Function KG816 Series Digital Time Switch provide: Rated AC frequency of 50Hz, rated AC control voltage 230V or below. Be used as time control components in automatic control circuit, according to the scheduled time to turn-on or off the circuits. Order Information KG816A Cover Output loops Rated control voltage Reference Non-transparent cover 16-on-16-off AC:230V KG816A230 Transparent cover 8-on-8-off AC:230V KG816B230 Technical Data Standard IEC 60947-5-1 Control time Setting value range from 1min to 168 hrs Operate by daily or weekly KG816B Using mode AC-15: 240V/3A; 400V/1.9A Countrol power ≤6kW 230VAC Rated thermal cur. 10A Accuracy ≤2s/day Mechanical life ≥1X106 Electrical life ≥1X105 Power loss ≤4.5W Temp. -5℃~+40℃ Display mode Digital LED display Time-set Mode Digital Keyswitch setting Battery Inner rechangable battery Install Mode Din rail mounted Management Power Energy Rated control voltage Overall Dimensions Unit: mm 87 36 45.5 87 66 167 Voltage Stabilizer Overview Single-phase TND 169 Type: Single-phase Specification: 0.5kVA, 1kVA 1.5kVA, 2kVA, 3kVA, 5kVA, 7kVA, 10kVA, 15kVA, 20kVA, 30kVA Three-phase SJW 171 Type: Three-phase Specification: 1.5kVA, 3kVA 4.5kVA, 6kVA, 9kVA, 15kVA, 20kVA, 30kVA, 45kVA, 60kVA Power Energy Management SBW 173 Type: Three-phase Compensation Specification: 10kVA, 15kVA 30kVA, 50kVA, 100kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA, 600kVA, 800kVA 168 TND Single-phase Full Automatic AC Voltage Stabilizer Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1 Function TND single-phase AC voltage stabilizer provide: This product is constructed by connecting three stabilizers with Y-connection Wide input voltage range, high efficiency, over-load protection, short adjusting time, high regulation accuracy, same input and output voltage waveform, small volume, less weight. It's available in the electric equipments and facilities in housing, school, shop, office and precision instrument for scientific experiment. Order Information Shape Desktop Cabinet Desktop Power rating Europe plug British plug Terminal connect 220V 0.5K TNDP5HE220 TNDP5HB220 - 1K TND1HE220 TND1HB220 - 1.5K TND1P5HE220 TND1P5HB220 - 2K - - TND2H220 3K - - TND3H220 5K - - TND5H220 7K - - TND7H220 10K 10K - - TND10H220 TND10GH220 15K - - TND15GH220 20K - - TND20GH220 30K - - TND30GH220 0.5K TNDP5HE230 TNDP5HB230 - 1K TND1HE230 TND1HB230 - 1.5K TND1P5HE230 TND1P5HB230 - 2K - - TND2H230 3K - - TND3H230 5K - - TND5H230 7K - - TND7H230 10K - - TND10H230 10K - - TND10GH230 15K - - TND15GH230 20K - - TND20GH230 30K - - TND30GH230 220V 230V 230V Reference Management Power Energy Cabinet Output voltage 169 TND Single-phase Full Automatic AC Voltage Stabilizer Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1 Technical Data Type TND0.5kVA~5kVA Voltage regulation accuracy 220±4%,110±4% Output voltage Undervoltage protection Overvoltage protection TND7kVA~30kVA 220±4% 184V±4V(set up according to the customers request) 246V±4V Phase single-phase Input voltage range 160V~240V Efficiency >90% Voltage regulation speed <1s(when input voltage change 10%) Frequency 50/60Hz Enviroment -50℃~40℃ below 90% temperature,relative temperature 2(500VA), 4(1000VA), 6(1500VA), 8(2000VA) 12(3000VA), 20(5000VA), 25(7000VA), 40(10KVA) 85(15KVA), 73(20KVA), 109(30KVA) 1500V/1min Rated maximum output current(A) Withstand voltage Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1 Certification: CE Overall Dimensions Unit: mm Power Energy Management Product shape Model Wide×Length×Hight Desktop TND-0.5 W 190 L 160 H 135 TND-1 205 190 155 TND-1.5 205 190 155 TND-2 240 270 200 TND-3 225 305 235 TND-5 225 310 290 TND-7 240 387 360 TND-10 240 387 360 TND-10 310 340 535 TND-15 340 360 640 TND-20 340 380 780 TND30 425 390 845 Cabinet type 170 SJW Three-phase Full Automatic AC Voltage Stabilizer Function SJW three-phase AC voltage stabilizer provide: This product is constructed by connecting three stabilizers with Y-connection Wide input voltage range, high efficiency, over-load protection, short adjusting time, high regulation accuracy, same input and output voltage waveform, small volume, less weight. It's available in the electric equipments and facilities in housing, factory, shool, shop, office and precision instrument for scientific experiment. Order Information Shape Desktop Cabinet Power rating Reference 1.5 kVA SJW1P5 3 kVA SJW3 4.5 kVA SJW4P5 6 kVA SJW6G 9 kVA SJW9G 15 kVA SJW15G 20 kVA SJW20G 30 kVA SJW30G 45 kVA SJW45G Technical Data Type Output voltage SJW 1.5KVA~60KVA Voltage regulation accuracy 380V ±4% Low-voltage protection 340V±7V(adjustable) Over-voltage protection 420V ±7V 280~415V Efficiency 90% Voltage regulation speed <1s(voltage fluctuation≥10%) Frequency 50/60Hz Waveform distortion: No additional distortion Withstand voltage 1500V/1min Temperature rise <+60℃ Environment temp. -5℃~+40℃ Management Power Energy Input voltage range Overall Dimensions 171 SJW Three-phase Full Automatic AC Voltage Stabilizer Overall Dimensions ■ Cabinet ELECTRIC WORKING PHASE A WORKING PHASE B WORKING PHASE C PROTECT OUTPUT VOLTAGE VOLTAGE TEST SJW9 HIGH ACCURACY FULL-AUTOMATIC AC VOLTAGE STABILIZER Shape Desktop Power Energy Management Cabinet 172 Model Wide x Length x Hight W L H SJW-1P5 485 315 165 SJW-3 485 315 165 SJW-4.5 485 315 165 SJW-6 278 322 665 SJW-9 320 325 750 SJW-15 350 350 855 SJW-20 425 390 845 SJW-30 440 415 875 SJW-45 550 450 1170 SJW-60 600 495 1300 SBW Three-phase Compensation AC Voltage Stabilizer Function SBW three-phase compensation AC voltage stabilizer provide: This product is designed and developed with the international advanced compensation technology. It can keep the output voltage in steady state automatically when the network voltage fluctuated or the load current varied. It's provided with over-voltage, over-current, phase sequence protection function. Order Information Power rating Reference 10kVA SBW10 15kVA SBW15 30kVA SBW30 50kVA SBW50 100kVA SBW100 150kVA SBW150 200kVA SBW200 250kVA SBW250 300kVA SBW300 400kVA SBW400 500kVA SBW500 600kVA SBW600 800kVA SBW800 Technical Data Output voltage SBW 10KVA~1600KVA Voltage regulation accuracy 380V ±3% Low-voltage protection 340V ±7V Over-voltage protection 425V ±7V Input voltage range 304~456 V Efficiency ≥98% Voltage regulation speed <1s(voltage fluctuation≥10%) Frequency 50/60Hz Waveform distortion ≤1% Insulation resistance ≥2MΩ Withstand voltage Temperature rise 2000V/1min <+60℃ Environment temp. -5℃~+40℃ Management Power Energy Type 173 SBW Three-phase Compensation AC Voltage Stabilizer Overall Dimensions Unit: mm Model Power Energy Management 174 Wide x Length x Hight W L H SBW-10 750 580 1170 SBW-20 750 580 1170 SBW-50 800 570 1300 SBW-100 850 645 1460 SBW-200 1050 750 1850 SBW-500 1400 1100 2100 SBW-800 1350 1100 2200 SBW-1000 1050 750 2200 SBW-1600 1300 1100 2200 Contents Industrial Control Components Control Signal 175-202 LD11 Indicator Light 177 LAY5 Pushbutton Switches 181 LAY7 Pushbutton Switches 191 LAY8 Pushbutton Switches 197 Accessories 203-221 RT16 Fuse 203 RT18 Fuse 206 CCF Series Cable Connector 209 CDPM Moving Industrial Plugs 211 CDP Fixed Industrial Plugs 212 CDSM Moving Industrial Sockets 213 CDSF Fixed Industrial Sockets 214 CDPS Multi-function Plugs and Sockets 215 TB Series Copper Terminal Blocks 217 DINR Din-rail 221 Industrial Control Components 175 Control Signal Overview Indicator Light LD11 177 IP degree:IP65 Specification AC/DC: 6V 12V 24V 36V 48V 110V 230V AC: 230V 400V Pushbutton Switches LAY5 181 LAY7 IP degree:IP55 IP degree:IP55 Specification Specification AC-15: 380V/2A 230V/3.3A AC-15: 660V/1.1A DC-13: 230V/0.5A 110V/1.1A 400V/2.0A 230V/3.3A DC-13: 440V/0.25A 230V/0.5A 110V/1A LAY8 IP degree:IP55 Industrial Control Components Specification AC-15: 660V/1.5A 400V/2.5A 230V/4.5A DC-13: 440V/0.2A 230V/0.4A 110V/0.8A 176 197 191 LD11 Indicator Light Standard: IEC 60947-5 Function LD11 Series of indicator light provide: Pilot signal, anticipating signals Emergency signals and other instructions incidents signal use Technical Data Rated voltage(V) AC/DC 6 12 24 36 48 110 230 AC 230 400 Rated current(mA) Working life(H) Brightness of light(cd/m2) Power frequency withstand voltage Degree of protection ≤50 30000 ≤20 ≥40 2500V AC 1min IP65 Order Information Installation dimension 22:¢22 Type Step-down Type A: Full cover 2: Resistance head & long type 4: Capacitance terminal type Button colour Reference AC.DC 6V LD1122A21T7 LD1122A21T3 LD1122A21T4 LD1122A21T5 LD1122A21T8 LD1122A21J7 LD1122A21J3 LD1122A21J4 LD1122A21J5 LD1122A21J8 LD1122A21B7 LD1122A21B3 LD1122A21B4 LD1122A21B5 LD1122A21B8 LD1122A21F7 LD1122A21F3 LD1122A21F4 LD1122A21F5 LD1122A21F8 LD1122A21M7 LD1122A21M3 LD1122A21M4 LD1122A21M5 LD1122A21M8 LD1122A41M7 LD1122A41M3 LD1122A41M4 LD1122A41M5 LD1122A41M8 AC.DC 12V AC.DC 24V AC.DC 110V AC.DC 230V AC 230V Overall Dimensions Unit:mm Industrial Control Components Rated voltage 177 LD11 Indicator Light Standard: IEC 60947-5 Order Information Installation dimension Type Step-down Type Button colour Rated voltage Reference AC 400V LD1122A41Q7 LD1122A41Q3 LD1122A41Q4 LD1122A41Q5 LD1122A41Q8 22:¢22 B: Half cover 2: Resistance head&long type terminal 4: Capacitance type AC.DC 6V LD1122B21T7 LD1122B21T3 LD1122B21T4 LD1122B21T5 LD1122B21T8 AC.DC 12V LD1122B21J7 LD1122B21J3 LD1122B21J4 LD1122B21J5 LD1122B21J8 AC.DC 24V LD1122B21B7 LD1122B21B3 LD1122B21B4 LD1122B21B5 LD1122B21B8 AC.DC 110V LD1122B21F7 LD1122B21F3 LD1122B21F4 LD1122B21F5 LD1122B21F8 AC.DC 230V LD1122B21M7 LD1122B21M3 LD1122B21M4 LD1122B21M5 Industrial Control Components LD1122B21M8 AC 230V LD1122B41M7 LD1122B41M3 LD1122B41M4 LD1122B41M5 LD1122B41M8 AC 400V LD1122B41Q7 LD1122B41Q3 LD1122B41Q4 LD1122B41Q5 LD1122B41Q8 178 Overall Dimensions Unit:mm LD11 Indicator Light Standard: IEC 60947-5 Order Information Installation dimension 22:¢22 Type Step-down Type C: Full cover 2: Resistance head & short type terminal 4: Capacitance type Button colour Rated voltage Reference AC.DC 6V LD1122C21T7 Overall Dimensions Unit:mm LD1122C21T3 LD1122C21T4 LD1122C21T5 LD1122C21T8 AC.DC 12V LD1122C21J7 LD1122C21J3 LD1122C21J4 LD1122C21J5 LD1122C21J8 AC.DC 24V LD1122C21B7 LD1122C21B3 LD1122C21B4 LD1122C21B5 LD1122C21B8 AC 230V LD1122C41M7 LD1122C41M3 LD1122C41M4 LD1122C41M5 LD1122C41M8 AC 400V LD1122C41Q7 LD1122C41Q3 LD1122C41Q4 LD1122C41Q5 LD1122C41Q8 Industrial Control Components 179 LD11 Indicator Light Standard: IEC 60947-5 Order Information Installation dimension 22:¢22 Type Step-down Type D: Half cover 2: Resistance head&short type terminal 4: Capacitance type Button colour Rated voltage Reference AC.DC 6V LD1122D21T7 LD1122D21T3 LD1122D21T4 LD1122D21T5 LD1122D21T8 AC.DC 12V LD1122D21J7 LD1122D21J3 LD1122D21J4 LD1122D21J5 LD1122D21J8 AC.DC 24V LD1122D21B7 LD1122D21B3 LD1122D21B4 LD1122D21B5 LD1122D21B8 AC 230V LD1122D41M7 LD1122D41M3 LD1122D41M4 LD1122D41M5 LD1122D41M8 AC 400V LD1122D41Q7 LD1122D41Q3 LD1122D41Q4 LD1122D41Q5 LD1122D41Q8 Industrial Control Components 180 Overall Dimensions Unit:mm LAY5 Pushbutton Switches Standard: IEC 60947-5 Function LAY5 series of pushbutton switches provide: Control and indicate the status of the circuit Technical Data Usage mode Rated valve Rated voltage (Ue) V AC-15 Rated current (Ie) A 380 2 230 3.3 Rated voltage (Ue) V Rated current (Ie) A 230 110 0.5 1.1 DC-13 Mechanical endurance 105 Electric endurance 105 3 0 Flush type , 1 0 Illuminated 1 Emergency stop, Selective-type, Key-tpye AC6( Flush type ) DC3( Illuminated ) 1 Emergency stop, Selective-type, Key-tpye Rated thermal current (Ith) A 6 IP55 Protect degree Illuminated pushbutton Power supplier voltage 6 12 24 ≤ 50%(40 ) 90%(20 V 110 230 380 LED Neon lamp Filament lamp Working Condition Temperature Ralative humidity -5 ~+40 ≤ 2000m Pollution grade 3 ) Industrial Control Components Above sea level 181 LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Flush Button Name Unit: MM Material Type Color NO + NC 1 White 1: 1NO LAY5BA15 2 Black 2: 1NC LAY5BA25 3 Green 3: 2NO LAY5BA31 4 Red 4: 2NC LAY5BA42 5 Yellow 5: 1NO+1NC LAY5BA55 LAY5 B Metal A Momentary 6 Blue E Plastic A Momentary 1 White 1: 1NO LAY5EA15 2: 1NC LAY5EA25 3 Green 3: 2NO LAY5EA31 4 Red 4: 2NC LAY5EA42 5 Yellow 5: 1NO+1NC LAY5EA55 LAY5EA65 Unit: MM Material Type B Metal D Selective button with short handle Operation NO + NC LAY5 Industrial Control Components 182 Dimension LAY5BA65 2 Black 6 Blue Selective Button Switch Name Reference 2:2p C R 3:3p L C R 4:2 p C R 5:3p L C R Reference 1: 1NO LAY5BD21 2: 1NC LAY5BD25 3: 2NO LAY5BD33 4: 2NC LAY5BD45 5: 1NO+1NC LAY5BD53 Dimension LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Selective Switches Name Material Unit: MM Operation Type NO + NC LAY5 E Plastic B Metal E Plastic D Selective switch with short handle 2:2 p 3:3 p C R L C R 4:2p C R 5:3 p L C R J Selective 2:2 p switch with short handle 3:3 p C R J Selective switch with short handle L C R 4:2p C R 5:3 p L C R 2:2 p C R 3:3 p L C R 4:2p C R 5:3 p L C R Reference 1: 1NO LAY5ED21 2: 1NC LAY5ED25 3: 2NO LAY5ED33 4: 2NC LAY5ED45 5: 1NO+1NC LAY5ED55 1: 1NO LAY5BJ21 2: 1NC LAY5BJ25 3: 2NO LAY5BJ33 4: 2NC LAY5BJ45 5: 1NO+1NC LAY5BJ55 1: 1NO LAY5EJ21 2: 1NC 3: 2NO LAY5EJ25 LAY5EJ33 4: 2NC LAY5EJ45 5: 1NO+1NC LAY5EJ55 Dimension Industrial Control Components 183 LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Key-operated Selective Switches Name Material Unit: MM Operation Type NO + NC LAY5 B Metal E Plastic G Key-operated 2:2 p selective switches 3:3 p C R L C R 4:2p reset C R 5:3 p reset L C R C R G Key-operated 2:2p selective switches 3:3 p L C R 4:2p reset C R 5:3 p reset L C R Reference 1: 1NO LAY5BG21 2: 1NC LAY5BG25 3: 2NO LAY5BG33 4: 2NC LAY5BG45 5: 1NO+1NC LAY5BG55 1: 1NO LAY5EG21 2: 1NC LAY5EG25 3: 2NO LAY5EG33 4: 2NC LAY5EG45 5: 1NO+1NC LAY5EG55 Mushroom Button Name Unit: MM Material Type Color 40 Mushroom 3 Green 4 Red NO + NC LAY5 Industrial Control Components B Metal C: Reference 1: 1NO LAY5BC31 2: 1NC LAY5BC42 3: 2NO LAY5BC35 4: 2NC LAY5BC45 5: 1NO+1NC 184 Dimension Dimension LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Mushroom Button Name Unit: MM Material Type Color 60 Mushroom 3 Green 4 Red NO + NC LAY5 B Metal R: Reference 1: 1NO LAY5BR31 2: 1NC LAY5BR42 3: 2NO LAY5BR35 4: 2NC LAY5BR45 Dimension 5: 1NO+1NC E Plastic C: 40 Mushroom 3 Green 4 Red 1: 1NO LAY5EC31 2: 1NC LAY5EC42 3: 2NO LAY5EC35 4: 2NC LAY5EC45 5: 1NO+1NC E Plastic R: 60 Mushroom 3 Green 4 Red 1: 1NO LAY5ER31 2: 1NC LAY5ER42 3: 2NO LAY5ER35 4: 2NC LAY5ER45 5: 1NO+1NC Industrial Control Components 185 LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Emergency Stop Button Name Material Unit: MM Type Head Color NO + NC 3 Green 1: 1NO LAY5BS431 LAY5 B Metal S: Emergency 4: 30 4 Red Reference 2: 1NC LAY5BS442 3: 2NO LAY5BS435 4: 2NC LAY5BS445 5: 1NO+1NC B Metal S: Emergency 5: 40 3 Green 1: 1NO LAY5BS531 4 Red 2: 1NC LAY5BS542 3: 2NO LAY5BS535 4: 2NC LAY5BS545 5: 1NO+1NC B Metal S: Emergency 6: 60 3 Green 4 Red 1: 1NO LAY5BS631 2: 1NC LAY5BS642 3: 2NO LAY5BS635 4: 2NC LAY5BS645 5: 1NO+1NC Industrial Control Components 186 Dimension LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Emergency Stop Button Name Unit: MM Material Type E Plastic S: Emergency Head Color NO + NC LAY5 4: 30 Reference 3 Green 1: 1NO LAY5ES431 4 Red 2: 1NC LAY5ES442 3: 2NO LAY5ES435 4: 2NC LAY5ES445 Dimension 5: 1NO+1NC E Plastic S: Emergency 5: 40 3 Green 4 Red 1: 1NO LAY5ES531 2: 1NC LAY5ES542 3: 2NO LAY5ES535 4: 2NC LAY5ES545 5: 1NO+1NC E Plastic S: Emergency 6: 60 3 Green 1: 1NO LAY5ES631 4 Red 2: 1NC LAY5ES642 3: 2NO LAY5ES635 4: 2NC LAY5ES645 5: 1NO+1NC Industrial Control Components 187 LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Unit: MM Two-head Button Name Material Type Head No.of head NO + NC LAY5 Industrial Control Components 188 Reference B Metal L8: Two-head 3: Flush button 2: 2 5: 1NO+1NC LAY5BL8325 B Metal L8 : Two-head 4: One high, one low 2: 2 5: 1NO+1NC LAY5BL8425 Dimension LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Illuminated Pushbutton Switches Name Material Type Color Voltage LAY5 NO + NC * B Metal W3 Flush Light * 1 White T:6V 1: 1NO N Neon LAY5BW31*5 3 Green B:24V 2: 1NC L LED LAY5BW33*1 4 Red F:110V 3: 2NO 5 Yellow Blank: N:230V 4: 2NC 6 Blue Q:380V 5: 1NO+1NC Filament * * LAY5BW34*2 * LAY5BW35*5 * LAY5BW36*5 * LAY5BW37*5 * LAY5BW38*5 * T:6V 5: 1NO+1NC N Neon LAY5BW84*5* 7 Pure white 8 Pure blue B Metal W8:Two head 4 One high one low B:24V L LED F:110V Blank: N:230V Filament Q:380V E Plastic W3 Flush T:6V 1: 1NO N Neon LAY5EW31*5 3 Green B:24V 2: 1NC L LED LAY5EW33*1 4 Red F:110V 3: 2NO N:230V Blank: 5 Yellow 4: 2NC Q:380V Filament 6 Blue 5: 1NO+1NC * * LAY5EW34*2 * LAY5EW35*5 * LAY5EW36*5 * LAY5EW37*5 * LAY5EW38*5 * T:6V 5: 1NO+1NC N Neon LAY5EW84*5* 8 Pure blue W8:Two head 4 One high one low B:24V L LED F:110V Blank: Filament N:230V Industrial Control Components 1 White 7 Pure white E Plastic Reference Q:380V Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp. 189 LAY5 Pushbutton Switches Standard: IEC 60947-5 Order Information Indication Lamp Name Unit: MM Material Type LAY5 Voltage Color * * B Metal V: Indication Light T:6V 1 White N Neon B:24V 3 Green L LED F:110V 4 Red N:230V 5 Yellow Blank: Q:380V 6 Blue 7 Pure white 8 Pure blue Filament Reference Dimension LAY5BV*1* LAY5BV*3* LAY5BV*4* LAY5BV*5* LAY5BV*6* LAY5BV*7* LAY5BV*8* Base Name Type Contact LAY5 BE Auxiliary contact 101: 1NO LAY5BE101 102: 1NC LAY5BE102 103: 2NO LAY5BE103 104: 2NC LAY5BE104 105: 1N0+1NC LAY5BE105 Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp. Industrial Control Components 190 Reference Dimension LAY7 Pushbutton Switches Standard: IEC 60947-5 Function LAY7 series of pushbutton switches provide: Control and indicate the status of the circuit Technical Data Usage mode Rated valve Rated voltage (Ue) V AC-15 Rated current (Ie) A 660 380 230 1.1 2 3.3 Rated voltage (Ue) V DC-13 Rated current (Ie) A 440 230 110 0.25 0.5 1 Mechanical endurance 105 3 0 Flush type , 1 0 Illuminated 0 . 5 Emergency stop, Selective-type,,Key-tpye Electric endurance 6 Flush type , 1 Illuminated 0 . 5 Emergency stop,,Selective-type,,Key-tpye 105 Rated thermal current l th Operation frequency Contact resistance A T /h m 10 1200 ≤ 50 Protect degree IP55 Illuminated pushbutton Power supplier voltage Working voltage Lifetime (Ue)V h Filament lamp Neon lamp LED 6, 12, 24 110, 220, 380 6, 12, 24 ≥ 1000 ≥ 2000 ≥ 3000 Working Condition Temperature -5 Ralative humidity ≤ 50%(40 ) Above sea level ≤ 2000m Pollution grade 3 ~+40 90%(20 ) Industrial Control Components 191 LAY7 Pushbutton Switches Standard: IEC 60947-5 Order Information Flush Button Name Unit: MM Type NO + NC Color Installation LAY7 BN Momentary Reference 1 White 2 Black 2 22 LAY711BN12 01: 1NC 3 25 LAY711BN22 20: 2NO 3 Green 4 30 LAY711BN32 02: 2NC 4 Red 5 Yellow LAY711BN42 6 Blue LAY711BN62 10: 1NO 11: 1NO+1NC 10: 1NO BNZS Maintained 01: 1NC LAY711BN52 3 Green 2 22 LAY711BNZS32 4 Red 3 25 LAY711BNZS42 4 30 3 Green 2 22 LAY711GN32 4 Red 3 25 LAY711GN42 4 30 3 Green 2 22 LAY711GNZS32 4 Red 3 25 LAY711GNZS42 4 30 20: 2NO 02: 2NC 11: 1NO+1NC 10: 1NO GN Momentary 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC Industrial Control Components 10: 1NO GNZS Maintained 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC 192 Dimension LAY7 Pushbutton Switches Standard: IEC 60947-5 Order Information Unit: MM Flush Button Name LAY7 NO + NC Type 10: 1NO JN Full protection Installation Color 01: 1NC Reference 3 Green 2 22 LAY711JN32 4 Red 3 25 LAY711JN42 4 30 20: 2NO Dimension 02: 2NC 11: 1NO+1NC Unit: MM Selective Switches Name Operation NO + NC Type 10: 1NO X Selective button with 20:2p 01: 1NC 20: 2NO short handle 21:2p Color Installation LAY7 C R C R 2 Black 2 22 LAY711X2022 3 Green 3 25 LAY711X2132 4 30 LAY711X3042 4 Red 01: 1NC 20: 2NO 30:3p L C R 31:3p L C R 33:3p L C R XB Selective 20:2 button with long handle 21:2 C R C R 02: 2NC 11: 1NO+1NC LAY720X3022 2 Black 2 22 LAY711XB2022 3 Green 3 25 LAY711XB2132 4 30 LAY711XB3042 Red 4 Industrial Control Components 10: 1NO Dimension LAY711X3122 02: 2NC 11: 1NO+1NC Reference LAY720XB3022 30:3 L C R 31:3 L C R 33:3 L C R LAY720XB3322 193 LAY7 Pushbutton Switches Standard: IEC 60947-5 Order Information Key-operated Selective Switches Name NO + NC Unit: MM Type Installation Operation LAY7 10: 1NO Y Key-operated 20:2p C R 21:2p C R 30:3p L C R 31:3p L C R 33:3p L C R 01: 1NC 20: 2NO Reference 2 22 LAY711Y202 3 25 LAY711Y212 4 30 LAY711Y302 LAY711Y312 02: 2NC 11: 1NO+1NC LAY720Y332 Unit: MM Mushroom Button Name NO + NC Type Color Installation LAY7 10: 1NO M Momentary 01: 1NC Reference 3 Green 2 22 LAY711M32 4 Red 3 25 LAY711M42 4 30 3 Green 2 22 LAY711MZS32 4 Red 3 25 LAY711MZS42 4 30 20: 2NO 02: 2NC 11: 1NO+1NC 10: 1NO Industrial Control Components 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC 194 Dimension MZS Maintained Dimension LAY7 Pushbutton Switches Standard: IEC 60947-5 Order Information Unit: MM Emergency Stop Button Name NO + NC Type Installation Color LAY7 10: 1NO 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC ZS:Emergency 3: Green 4: Red 2: Φ22 3: Φ25 4: Φ30 Reference Dimension LAY710ZS32 LAY701ZS42 LAY711ZS32 LAY711ZS42 Unit: MM Illuminated Pushbutton Switches Name NO + NC Type Color LAY7 Voltage Installation * 10: 1NO D: Momentary 01: NC (Illuminated) 20: 2NC 02: 2NC 11: 1NO+1NC 3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue 2: Φ22 T: 6V B: 24V 3: Φ25 F: 110V 4: Φ30 N: 230V Q: 380V DZS: Maintained 10: 1NO (Illuminated) 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC 3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue T: 6V 2: Φ22 B: 24V 3: Φ25 F: 110V 4: Φ30 N: 230V Q: 380V Light * N Neon L LED Blank: Filament N Neon L LED Blank: Filament Reference Dimension LAY711D3*2 * LAY711D4*2 * LAY711D5*2 * * LAY711D7*2 * LAY711D8*2 * LAY711D6*2 LAY711DZS2*2 * LAY711DZS4*2* LAY711DZS5*2* LAY711DZS6*2* LAY711DZS7*2 * LAY711DZS8*2* 3: Green 4: Red DMZS: Maintained 3: Green 10: 1NO 4: Red (Illuminated) 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC T: 6V 2: Φ22 B: 24V 3: Φ25 F: 110V 4: Φ30 N: 230V Q: 380V T: 6V 2: Φ22 B: 24V 3: Φ25 F: 110V 4: Φ30 N: 230V Q: 380V N Neon L LED Blank: Filament LAY711DM3*2 * LAY711DM4*2 * N Neon LAY711DMZS3*2 L LED LAY711DMZS4*2 Blank: Filament Industrial Control Components DM: Momentary 10: 1NO (Illuminated) 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC * * Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp. 195 LAY7 Pushbutton Switches Standard: IEC 60947-5 Order Information Illuminated Selective Switches Name NO + NC Unit: MM Operation Type Light Color Voltage Install LAY7 * XD: Selective 20:2p (Illuminated) 10: 1NO 01: 1NC C R Reference 3 Green T: 6V 2 22 N Neon LAY711XD203*2 4 Red B: 24V 3 25 L LED LAY711XD204*2 F: 110V 4 30 Blank: Filament 20: 2NO 02: 2NC * N: 230V 30:3p L C R Q: 380V 11: 1NO+1NC * * LAY711XD303*2 * LAY711XD304*2 * Indication Lamp Name Unit: MM Type Color Voltage Install * LAY7 Reference XD1 Filament 1 White T: 6V XD2 Neon 3 Green B: 24V LAY7XD23*2 XD3 LED 4 Red F: 110V LAY7XD34*2 5 Yellow N: 230V LAY7XD15*2 6 Blue Q: 380V LAY7XD26*2 2 22 Dimension LAY7XD11*2 7 Pure white LAY7XD37*2 8 Pure blue LAY7XD38*2 Base Unit: MM Name Type Contact Industrial Control Components LAY7 BE Auxiliary contact 101: 1NO Reference LAY7BE101 102: 1NC LAY7BE102 103: 2NO LAY7BE103 104: 2NC LAY7BE104 105: 1N0+1NC LAY7BE105 Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp. 196 Dimension Dimension LAY8 Pushbutton Switches Standard: IEC 60947-5 Function LAY8 series of pushbutton switches provide: Control and indicate the status of the circuit Technical Data Usage mode AC-15 DC-13 Rated valve Rated voltage (Ue) V Rated current (Ie) A 660 380 230 1.5 2.5 4.5 Rated voltage (Ue) V Rated current (Ie) A 440 230 0.2 0.4 110 0.8 Mechanical endurance 105 3 0 Flush type , 3 Selective 0 . 5 Emergency stop, Key-tpye Electric endurance 6( Flush type ) , 1( Illuminated ) 105 0 . 5 Emergency stop, Key-tpye 10 Rated thermal current(Ith)A Contact resistance ≤50 m IP55 Protect degree Illuminated pushbutton Rated working voltage (Ue)V 6 12 24 36 48 110 220 Power supply AC, DC AC Rated working current (Ie)mA ≤ 50 ≤ 20 230 380 Working Condition -5 ~+40 Ralative humidity ≤ 50%(40 ) Above sea level ≤ 2000m Pollution grade 3 90%(20 ) Industrial Control Components Temperature 197 LAY8 Pushbutton Switches Standard: IEC 60947-5 Order Information Unit: MM Flush Button Name LAY8 NO + NC Type 10: 1NO BN Momentary 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC 10: 1NO BNZS Maintained 01: 1NC 20: 2NO Color 1 White 2 Black Reference LAY811BN1 LAY811BN2 3 Green LAY811BN3 4 Red 5 Yellow LAY811BN4 6 Blue LAY811BN6 LAY811BN5 3 Green LAY811BNZS3 4 Red 5 Yellow LAY811BNZS4 3 Green LAY811S3 4 Red 5 Yellow LAY811S4 LAY811BNZS5 02: 2NC 11: 1NO+1NC 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC Industrial Control Components 198 S Waterproof LAY811S5 Dimension LAY8 Pushbutton Switches Standard: IEC 60947-5 Order Information Unit: MM Selective Switches Name NO + NC Type 10: 1NO X Selective button with short handle Operation Color LAY8 01: 1NC 20: 2NO 20:2p 21:2p C R C R 2 Black LAY811X202 3 Green LAY811X213 4 Red LAY811X304 02: 2NC Dimension LAY811X312 11: 1NO+1NC 10: 1NO XB Selective 01: 1NC button with 20: 2NO long handle 30:3p L C R 31:3p L C R 33:3p L C R 20:2p C R 21:2p C R 02: 2NC 11: 1NO+1NC Reference LAY820X332 2 Black LAY811XB202 3 Green LAY811XB213 4 Red LAY811XB304 LAY811XB312 30:3p L C R 31:3p L C R 33:3p L C R LAY820XB332 Industrial Control Components 199 LAY8 Pushbutton Switches Standard: IEC 60947-5 Order Information Key-operated Selective Switch Name NO + NC Unit: MM Type Operation LAY8 10: 1NO Y Key-operated 20:2p C R 21:2p C R 30:3p L C R 31:3p L C R 33:3p L C R 01: 1NC Reference LAY811Y20 LAY811Y21 20: 2NO 02: 2NC LAY820Y30 LAY811Y31 11: 1NO+1NC LAY811Y33 Mushroom Button Name Unit: MM NO + NC Type 10: 1NO M Momentary Color LAY8 01: 1NC Reference 3 Green LAY811M3 4 Red LAY811M4 20: 2NO 02: 2NC 11: 1NO+1NC Industrial Control Components 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC 200 Dimension MZS Maintained 3 Green 4 Red LAY811MZS3 LAY811MZS4 Dimension LAY8 Pushbutton Switches Standard: IEC 60947-5 Order Information Unit: MM Emergency Stop Button Name Type NO + NC Color Reference LAY8 ZS Emergency 10: 1NO 01: 1NC 3 Green LAY811ZS3 4 Red LAY811ZS4 Dimension 20: 2NO 02: 2NC 11: 1NO+1NC Unit: MM Illuminated Pushbutton Switches Name LAY8 NO + NC Type Color Voltage Power * 10: 1NO 01: 1NC D: Momentary (Illuminated) 20: 2NO 02: 2NC 11: 1NO+1NC 3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue T: 6V B: 24V F: 110V N: 230V Q: 380V 2: AC/DC 4: AC Reference Dimension LAY811D3*4 LAY811D4*4 LAY811D5*2 LAY811D6*2 LAY811D7*2 LAY811D8*2 10: 1NO 01: 1NC DZS: Maintained (Illuminated) 20: 2NO 02: 2NC 11: 1NO+1NC 3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue T: 6V B: 24V F: 110V N: 230V Q: 380V 2: AC/DC 4: AC LAY811DZS3*4 LAY811DZS4*4 LAY811DZS5*2 LAY811DZS6*2 LAY811DZS7*4 LAY811DZS8*4 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC DS:Waterproof (Illuminated) 3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue T: 6V B: 24V F: 110V N: 230V Q: 380V 2: AC/DC 4: AC Industrial Control Components 10: 1NO LAY811DS3*4 LAY811DS4*4 LAY811DS5*2 Note:Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp. 201 LAY8 Pushbutton Switches Standard: IEC 60947-5 Order Information Unit: MM Base Name LAY8 Type BE Auxiliary contact Industrial Control Components 202 Contact 101: 1NO Reference LAY8BE101 102: 1NC LAY8BE102 103: 2NO LAY8BE103 104: 2NC LAY8BE104 105: 1N0+1NC LAY8BE105 Dimension RT16 Fuse Standard: IEC 60269 Function RT16 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current Order Information Fuse-link RT16-00 Rate current In(A) Suitable fuse bases 2 RT16-00 Weight(g) Reference 170 RT16002 4 RT16004 6 RT16006 8 RT16008 10 RT160010 12 RT160012 16 RT160016 20 RT160020 25 RT160025 32 RT160032 40 RT160040 50 RT160050 63 RT160063 80 RT160080 100 RT1600100 125 RT1600125 160 RT16-1 80 RT1600160 RT16-1 450 RT161100 125 RT161125 160 RT161160 200 RT161200 250 RT16-2 125 RT161250 RT16-2 660 RT162125 RT162160 200 RT162200 250 RT162250 300 RT162300 315 RT162315 355 RT162355 315 Industrial Control Components 160 400 RT16-3 RT16180 100 RT162400 RT16-3 850 RT163315 355 RT163355 400 RT163400 450 RT163450 500 RT163500 630 RT163630 203 RT16 Fuse Standard: IEC 60269 Order Information Fuse Base Rate current In(A) Material Weight(g) Reference RT16-00 160 Ceramic 200 RT1600ZT RT1600ZS Resin RT16-1 250 RT161ZT 700 Ceramic RT161ZS Resin RT16-2 400 RT162ZT 1150 Ceramic RT162ZS Resin RT16-3 630 RT163ZT 1280 Ceramic RT163ZS Resin Technical Data Rated working current 2-630A Rated operation voltage 500/660V Rated breaking capacity 120KA(500V), 50KA(660V) Accessory-puller Industrial Control Components 204 Material Usage Reference ABS(frame resistance) Assemble and replace RT16 fuse RT16C RT16 Fuse Standard: IEC 60269 Overall Dimensions Unit: mm RT16-00 RT16-1 RT16-2 RT16-3 a 78.5 135 150 150 b 29 48 58 67 c 57 62 72 85 d 49 67 67 67 e 6 6 6 6 A 30 58 64 64 B 120 200 250 250 C1 61 83 99 105 C2 85 96 112 120 D 100 175 200 210 E 25 25 25 25 F 7.5 10.5 10.5 10.5 30 30 30 G Industrial Control Components Type 205 RT18 Fuse Standard: IEC 60269 Function RT18 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current Order Information Cylindrical Fuse Rate current In(A) Weight(g) Reference RT18-32 2 8 RT1810382 RT18-63 Industrial Control Components 206 4 RT1810384 6 RT1810386 8 RT1810388 10 RT18103810 12 RT18103812 16 RT18103816 20 RT18103820 25 RT18103825 32 RT18103832 2 20 RT1814512 4 RT1814514 6 RT1814516 8 RT1814518 10 RT18145110 12 RT18145112 16 RT18145116 20 RT18145120 25 RT18145125 32 RT18145132 40 RT18145140 50 RT18145150 63 RT18145163 RT18 Fuse Standard: IEC 60269 Order Information Holder of fuse Pole Rate current In(A) Note Weight (g) Reference RT18-32X 1P 32 Material:Resin 82 RT1832ZXB With Indicator 2P RT1832Z2XB 3P RT18-32 1P RT1832Z3XB Material:Resin 32 2P 82 RT1832Z2B Without Indicator 3P RT18-32X 1P RT1832Z3B Material:Nylon 32 2P 82 With Indicator 1P RT1832Z3X Material:Nylon 32 2P 82 1P RT1832Z3 Material:Resin 63 2P 206 With Indicator 1P RT1863ZXB RT1863Z2XB 3P RT18-63 RT1832Z RT1832Z2 Without Indicator 3P RT18-63X RT1832ZX RT1832Z2X 3P RT18-32 RT1832ZB RT1863Z3XB Material:Resin 63 2P Without Indicator 3P 206 RT1863ZB RT1863Z2B RT1863Z3B Technical Data 2-63A Rated operation voltage 380V Rated breaking capacity 100KA Industrial Control Components Rated working current 207 RT18 Fuse Standard: IEC 60269 Overall Dimensions Unit: mm Cylindrical Fuse Type Size L C Hmax RT18-32 10×38 38±0.6 10.3±0.1 10.5 RT18-63 14×51 51 +0.6 -1.0 14.3±0.1 13.8 Holder of fuse Industrial Control Components 208 Type A B C D E F G RT18-32 63 60 79 35 80 18 54 RT18-63 78 76 103 35 110 25 75 CCF Series Cable Connector Technical Data Thread specification: International metric standard Material: Nylon 66 Working temp.: -40℃~+100℃ Max temp. in short time: +120℃. Installation: Standard threaded hole Colour: Black & gray Order Information Cabel range (mm) Thread external diameter (mm) Panel hole (mm) Thread length (mm) Spanner size A&F Reference Black Gray 7.6-4.6 12 12.5 8.5 18/19 CCFMG12IP68B CCFMG12IP68W 10-6 16 16.5 15 22/22 CCFMG16IP68B CCFMG16IP68W 14-9 20 20.5 15 27/27 CCFMG20IP68B CCFMG20IP68W 18-13 25 25.5 15 33/33 CCFMG25IP68B CCFMG25IP68W 25-18 32 33 15 41/41 CCFMG32IP68B CCFMG32IP68W 30-24 40 41 20 50/50 CCFMG40IP68B CCFMG40IP68W 41-30 50 51 22 62/62 CCFMG50IP68B CCFMG50IP68W 51-40 63 64 25 75/75 CCFMG63IP68B CCFMG63IP68W 7-3.5 7 12.5 8 17/19 --- B CCFPG7IP54W 8-4.5 9 15.2 8.5 22/19 --- B CCFPG9IP54W 10.5-6 11 18.6 9 24/22 --- 12.5-7.5 13.5 20.4 9.6 27/24 14-8.5 16 22.5 10 30/27 18-12.5 21 28.3 12 36/33 --- CCFPG21IP54W 25-18 29 37 15 46/41 --- CCFPG29IP54W 30-23 36 47 15 57/50 --- CCFPG36IP54W 39-30 42 54 15.5 64/62 --- CCFPG42IP54W 45-35 48 59.3 15.5 70/65 --- CCFPG48IP54W --C --- CCFPG11IP54W B B CCFPG135IP54W CCFPG16IP54W Industrial Control Components 209 Industrial Plugs&Sockets Overview CDPM Moving Industrial plugs 211 Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A CDP Fixed Industrial Plugs 212 Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A CDSM Moving Industrial Sockets 213 Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A CDSF Fixed Industrial Sockets 214 Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A Industrial Control Components CDPS Multi-function Plugs and Sockets Pole: 2P+E Voltage:110V, 230V Current:16A 210 215 CDPM Moving Industrial Plugs Standard: IEC 60309-1-2 Moving Industrial Plugs 16Amp 32Amp a b 63 67 63 CDPM463IP67 125 CDPM4125IP67 63 CDPM563IP67 125 CDPM5125IP67 5 125Amp 3 4 5 230 230 230 295 295 295 109 109 109 124 124 124 36 36 36 50 50 50 Industrial Control Components 3P+N+E CDPM3125IP67 a b c 4 400-415 3P+E 67 63Amp 3 125 67 CDPM363IP67 230-250 2P+E PG 400-415 211 CDP Fixed Industrial Plugs Standard: IEC 60309-1-2 Fixed Industrial Plugs CDP316IP441 CDP332IP441 CDP316IP44 CDP332IP44 CDP416IP44 CDP432IP44 CDP516IP44 CDP532IP44 67 230~250 63 CDP363IP67 63Amp 67 400~415 63 CDP463196 3P+E a b Industrial Control Components c d e f 67 3P+N+E 212 400~415 63 CDP5631967 g h PG 3 193 122 157 109 19 6 288 127 29 4 193 122 157 109 19 6 288 127 29 5 193 122 157 109 19 6 288 127 29 CDSM Moving Industrial Sockets Standard: IEC 60309-1-2 Moving Industrial Sockets CDSM316IP441 16Amp 32Amp 4 5 3 4 5 Poles 3 a 130 131 139 149 149 154 b 66 76 90 90 90 100 a 67 CDSM3125IP67 63 CDSM463IP67 PG 125 CDSM4125IP67 63 CDSM563IP67 125 CDSM5125IP67 a b PG 63Amp 125Amp 3 4 5 240 240 240 3 4 5 300 300 300 112 112 112 36 36 36 126 126 126 50 50 50 400~415 213 Industrial Control Components 3P+N+E 125 b 400~415 3P+E 67 CDSM363IP67 230~250 2P+E 67 63 CDSF Fixed Industrial Sockets Standard: IEC 60309-1-2 Fixed Industrial Sockets Pole No. IP 44 Nominal voltage(V) 3P+E 3P+N+E 44 44 16 CDSF316IP441 32 CDSF332IP441 16 CDSF316IP44 32 CDSF332IP44 16 CDSF416IP44 230~250 400~415 32 CDSF432IP44 230~400 16 CDSF516IP44 240~415 32 CDSF532IP44 63 CDSF363IP67 125 CDSF3125IP67 63 CDSF463IP67 67 3 4 5 3 5 5 a 128 128 129 b 86 90 96 97 97 104 M 25 25 25 25 25 141 141 143 25 230~250 Industrial Control Components 67 230~400 63 CDSF4125IP67 CDSF563IP67 67 3P+N+E 240~415 125 CDSF5125IP67 125Amp 63Amp Poles 400~415 125 214 32Amp 16Amp Poles 44 2P+E 3P+E Reference 110~130 2P+E 2P+E Nominal current(A) 3 4 5 3 4 5 a 193 193 193 220 220 220 b 122 122 122 140 140 140 c 157 157 157 185 185 185 d 109 109 109 130 130 130 e 19 19 19 17 17 17 f 6 6 6 8 8 8 g 270 270 270 320 320 320 h 130 130 130 150 150 150 PG 29 29 29 36 36 36 CDPS Multi-function Plugs&Sockets Standard: IEC 60309-1-2 Multi-function Plugs and Sockets 1 Plug 1 Plug 1 Plug 1 Plug Industrial Control Components 215 Copper Terminal Block Overview TB010 217 Hole:4, 6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150 TB019 218 Hole:4, 6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150 TB007 219 Hole:6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150 TB043 220 Hole:78, 109, 116, 133 Hole diameter(mm):5~9 Screw dimension(mm):M4*8~M6*12 Max current(A):100~200 Industrial Control Components TB112 220 Hole:2x7, 2x15, 4x7, 4x11, 4x15 Hole diameter(mm):5.2 Screw dimension(mm):M4 Max current(A):125 216 TB010 Series Copper Terminal Block Order Information Industrial Control Components 217 TB019 Series Copper Terminal Block Order Information Industrial Control Components 218 TB007 Series Copper Terminal Block Order Information Industrial Control Components 219 TB112 Series Copper Terminal Blocks TB043 Series Copper Terminal Blocks Order Information 65 132 65 132 Industrial Control Components 220 DIN Rail Series Order Information Thickness(mm) Reference 0.8 CDIN01E* 0.9 CDIN01N* 1.0 CDIN02T* * means length 1000=1000mm 2000=2000mm 5000=5000mm Overall Dimensions Unit:mm Industrial Control Components 221 A Company to Serve You Where You Are E-mail Address:[email protected] Algeria Phone: +213 5 600 600 11 Chile Phone:+56-2-4822100 Philippines / Laos / Bangladesh Phone:+86 158 6807 8915 Colombia / Venezuela / Ecuador / Peru / Bolivia Phone:+57 3212056531 Russia / Kazakhstan Phone: +7 916 693 59 84 Egypt Phone:+20 10 011 3238 - +20 11 811 3546 Santo Domingo / Trinidad and Tobago / Jamaica Phone: +809 861 5803 Israel Phone:+972 543311087 Kenya / Tanzania / Uganda / Rwanda / Burundi Phone:+97150 5536433 Malaysia Phone:+601 93227688 222 Pakistan Phone:+92 300 8465 789 Saudi Arabia / Yemen Phone:+966-50 440 62 69 Turkey / Romania / Serbia / Bulgaria / Macedonia / Montenegro / Albania / Moldova / Syria / Lebanon / Jordan / Iran / Iraq / Central Asia Phone:+90 5335256771 Morocco Phone:+212 661 114 6999 UAE / Qatar / Oman / Bahrain / Kuwait Phone:+97150 5536433 Nigeria / Ghana / Liberia Phone:+234 8035059040 Vietnam / Cambodia Phone:+8490 381 3973 Memo 223 Memo 224 Jan.2011