Cables - Condumex Inc.

Transcription

Cables - Condumex Inc.
RoHS
DATA, COAXIAL
AND ELECTRONIC
M.R.
D A TA , C O A X I A L ,
A N D EL E CTRON I C
ECOLGICAL
Telecom Cables
Cables
RoHS
M.R.
Index
ECOLGICAL
Telecom Cables
2
3-5
6
7
8-11
12
13-16
17-18
19-20
21-33
34-37
• SOLID MULTI-CONDUCTOR CABLES
• STRANDED MULTI-CONDUCTOR CABLES
• SPEAKER/ZIP WIRE
• THERMOSTAT CABLE
• FIRE ALARM CABLE
• CATEGORY 3 CABLE
• BRAVOTWIST™ CATEGORY 5E
• BRAVOTWIST™ CATEGORY 5E+
• BRAVOTWIST™ CATEGORY 6
• COAXIAL CABLE
• COMPOSITE/HOME CONTROL CABLES
Condumex Wire and Cable
5-05
1
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Solid - Unshielded Multi-Conductor Cable
M.R.
ECOLGICAL
Telecom Cables
SOLID MULTI-CONDUCTOR CABLE
DECRIPTION:
• Solid bare copper conductor 24 or 22 AWG
• Semirigid PVC insulation
• PVC Jacket
SPECIFICATIONS:
NEC 800
UL-444
ETL Listed
CMR or CL2R
Product
Code
631737
Gauge
631722
631724
631726
631728
631731
Standard stocked lengths of 1000 ft or 500 ft,
in coil packs or pull boxes.
NEC 725
RoHS
24
Number of
Conductors
4
Insulation
Thickness
0.006”
Jacket
Thickness
0.0135”
Overall
Diameter
0.110”
Net Weight
Lb/mft
9
22
22
22
22
22
2
4
6
11
12
0.006”
0.006”
0.006”
0.006”
0.006”
0.0135”
0.0135”
0.0135”
0.0135”
0.0135”
0.105”
0.124”
0.148”
0.170”
0.186”
7
12
18
22
32
Conductor
Gauge
AWG
Conductor Resistance
D.C. Maximum
Ù/kft 200C
Temperature
Rating
24
26.80
60 C
22
APPLICATION:
Burglar alarm, audio control systems,
limited circuits.
17.60
Voltage
Rating
0
300 V
0
300 V
60 C
*All values are nominal,
and subject to
manufacturing tolerances.
Non-Stocked item, subject to minimum quantity.
Condumex Wire and Cable
9-04
2
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Stranded - Unshielded Multi-Conductor Cable
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Stranded bare copper conductor 22, 18, 16, or 14 AWG
• Semirigid PVC insulation
• PVC Jacket
• CMR / CL3R / FPLR
• Sunlight resistant
SPECIFICATIONS:
NEC 725/800 UL-44 ETL CL-13
APPLICATION:
Burglar alarm, audio control systems,
limited circuits.
Standard lengths of 1000 ft or 500 ft,
in reels or boxes.
RoHS
Product
Code
Gauge
Number of
Conductors
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
Lb/mft
656050
656052
656054
656056
656058
656059
22
22
22
22
22
22
2
4
6
8
10
12
0.006”
0.006”
0.006”
0.006”
0.006”
0.006”
0.0135”
0.0135”
0.0135”
0.0135”
0.0135”
0.0135”
0.107”
0.139”
0.155”
0.185”
0.242”
0.273”
8
15
20
26
32
37
656021
656023
656025
18
18
18
2
4
6
0.009”
0.009”
0.009”
0.0135”
0.0135”
0.0135”
0.148”
0.187”
0.213”
17
29
42
656018
656020
16
16
2
4
0.010”
0.010”
0.0175”
0.0175”
0.183”
0.233”
25
48
656016
656017
14
14
2
4
0.020”
0.020”
0.020”
0.020”
0.248”
0.318”
42
80
Conductor
Gauge
AWG
Conductor
Construction
Wire/AWG
Conductor Resistance
D.C. Maximum
Ù/kft @ 200C
Temperature
Rating
0
C
22
7/30
16.3
60 C
18
19/31
6.55
60 C
Voltage
Rating
0
300 V
0
300 V
0
16
26/30
4.00
60 C
300 V
14
41/301
2.60
600C
300 V
Condumex Wire and Cable
Non-Stocked item, subject to minimum
quantity.
*All values are nominal,
and subject to
manufacturing tolerances.
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
9-04
3
RoHS
Stranded - Shielded Multi-Conductor Cable
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION::
• Stranded bare copper conductor 22,18,16 or 14 AWG
• Semirigid PVC insulation
• Aluminum Foil - Polyester Shield
• Drain Wire
• CMR / CL3R / FPLR
• PVC Jacket
• Sunlight resistant
4
SPECIFICATIONS:
NEC 725/800, UL-444/13
ETL Listed RoHS
Product
Code
Gauge
Number of
Conductors
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
Lb/mft
656090
656091
656092
656094
22
22
22
22
2
3
4
6
22
8
0.0135”
0.0135”
0.0135”
0.0135”
0.0135”
0.135”
0.136”
0.162”
0.181”
0.208”
14
16
20
27
656096
0.006”
0.006”
0.006”
0.006”
0.006”
34
656070
656071
656072
656074
18
18
18
18
2
3
4
6
0.008”
0.008”
0.008”
0.008”
0.0135”
0.0135”
0.0135”
0.0135”
0.115”
0.173”
0.212”
0.245”
24
30
38
52
656065
656067
16
16
2
4
0.010”
0.010”
0.0175”
0.0175”
0.212”
0.262”
33
58
Conductor
Gauge
AWG
Conductor
Construction
Wire/AWG
Conductor Resistance
D.C. Maximum
0
Ù/kft @ 20 C
Temperature
Rating
0
C
Voltage
Rating
22
7/30
16.30
600C
300 V
18
19/31
6.55
600C
300 V
16
26/30
4.00
600C
300 V
Condumex Wire and Cable
9-04
APPLICATION:
Burglar alarm, audio control systems,
limited circuits.
Standard lengths of 1000 ft or 500 ft,
in reels or boxes.
th
Non-Stocked item, subject to minimum
quantity.
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
High Strand - Unshielded Multi-Conductor Cable
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• High strand copper conductor 16, 14, or 12 AWG
• Semirigid PVC insulation
• Tissue paper wrap
• Nylon rip cord
• PVC Jacket
• CL3R
APPLICATION:
Burglar alarm, audio control systems,
limited circuits.
Standard lengths of 1000 ft or 500 ft,
in reels or boxes.
SPECIFICATIONS:
NEC 725/800 UL-444/13 ETL RoHS
Product
Code
Gauge
Number of
Conductors
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
Lb/mft
656018HS
656020HS
16
16
2
4
0.015”
0.015”
0.020”
0.020”
0.202”
0.254”
29
52
656016HS
656017HS
14
14
2
4
0.020”
0.020”
0.020”
0.020”
0.256”
-
47
-
TBA
12
2
-
-
-
-
Conductor
Gauge
AWG
Conductor
Construction
Wire/AWG
Conductor Resistance
D.C. Maximum
Ù/kft @ 200C
Temperature
Rating
0
C
16
65/34
4.02
60 C
14
65/32
2.60
600C
12
-
-
60 C
Condumex Wire and Cable
0
0
Voltage
Rating
300 V
Non-Stocked item, subject to minimum
quantity.
*All values are nominal,
and subject to
manufacturing tolerances.
300 V
300 V
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
5
RoHS
Speaker/Zip Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Stranded copper conductors 22, 18, or 16 AWG
• PVC insulation
• CL2
APPLICATION:
Burglar alarm, audio control systems,
limited circuits.
STANDARD LENGTH
Standard lengths of 1000 ft, 500 ft,
250 ft reels or boxes.
SPECIFICATIONS:
NEC 725
UL13
RoHS
Product
Code
Number of
Conductors/
Gauge
Jacket
Thickness
External
Dimensions
Inches
Net
Weight
Lb/kft
720553
*720559
22
22
0.02”
0.02”
0.132 x 0.070”
0.132 x 0.070”
9
9
720583
18
0.022”
0.169 x 0.089”
17
720600
16
0.024”
0.201 x 0.110”
28
* Non UL-approved
Conductor
Construction
Wire/AWG
7/30
Bare Copper
16.30
Tinned Copper
17.10
300 V
18
19/31
6.55
6.90
300 V
16
26/30
4.00
4.20
300 V
Condumex Wire and Cable
8-04
6
Conductor Resistance
D.C. Maximum
Ù/kft @ 200C
Conductor
Gauge
AWG
22
th
Voltage
Rating
*All values are nominal,
and subject to
manufacturing tolerances.
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Thermostat / Control Cables
M.R.
ECOLGICAL
Telecom Cables
APPLICATION:
Thermostat cable for, air condition control,
heating control, intercom systems.
DESCRIPTION:
• Solid bare copper conductors 20 and 18 AWG
• Semirigid PVC insulation
• Sunlight resistant brown PVC Jacket
• CL2R
STANDARD LENGTH
SPECIFICATIONS:
NEC 725 UL-13 ETL Listed
RoHS
Standard lengths of 500 ft or 250 ft
reels. Brown in stock, white available
with minimum purchase requirement.
Product
Code
Gauge
Number of
Conductors
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
Lb/kft
666510
666511
666512
666513
666514
666516
18
18
18
18
18
18
2
3
4
5
6
8
0.0075”
0.0075”
0.0075”
0.0075”
0.0075”
0.0075”
0.013”
0.013”
0.013”
0.013”
0.013”
0.013”
0.126”
0.129”
0.161”
0.185”
0.185”
0.220”
14
20
27
33
40
52
666520
666521
666522
666523
666524
666525
666527
20
20
20
20
20
20
20
2
3
4
5
6
7
9
0.006”
0.006”
0.006”
0.006”
0.006”
0.006”
0.006”
0.013”
0.013”
0.013”
0.013”
0.013”
0.013”
0.013”
0.105”
0.106”
0.131”
0.150”
0.150”
0.210”
0.224”
10
13
18
22
26
31
38
Conductor
Gauge
AWG
Conductor Resistance
D.C. Maximum
Ù/kft @ 200C
Temperature
Rating
0
C
Voltage
Rating
20
10.12
60
300 V
18
6.40
60
300 V
Condumex Wire and Cable
Non-Stocked item, subject to minimum
quantity.
*All values are nominal,
and subject to
manufacturing tolerances.
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
8-04
7
RoHS
UNSHIELDED FIRE ALARM CABLE
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Solid bare copper conductor 22, 18, 16 or 14 AWG
• Semirigid PVC insulation
• Insulated conductors are cabled in all constructions
• PVC jacket
• Rip-Cord
• FPLR
SPECIFICATIONS
NEC 760 UL-1424 ETL Listed RoHS
*All values are nominal,
and subject to
manufacturing tolerances.
Gauge
Number of
Conductors
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
Lb/kft
666551
22
4
0.075”
0.020”
0.137”
15
666556
666558
666559
666560
18
18
18
18
2
4
6
8
0.010”
0.010”
0.010”
0.010”
0.020”
0.020”
0.020”
0.020”
0.146”
0.183”
—
0.265”
17
31
51
58
666591
666593
16
16
2
4
0.010”
0.010”
0.020”
0.020”
0.165”
0.208”
24
44
666596
666597
14
14
2
4
0.013”
0.013”
0.020”
0.020”
0.205”
0.260”
36
68
Conductor
Gauge
AWG
Conductor Resistance
D.C. Maximum
Ù/kft @ 200C
Temperature
Rating
0
C
0
0
300 V
0
300 V
16.30
-20 C to 60 C
6.40
-20 C to 60 C
16
4.00
-20 C to 60 C
2.52
Voltage
Rating
0
22
18
Condumex Wire and Cable
8
Standard lengths of 1000 ft or 500 ft reels
or boxes.
Product
Code
14
8-04
APPLICATION:
Smoke detectors, burglar
alarm, critical control circuits, power
limited circuits.
0
0
300 V
0
0
300 V
-20 C to 60 C
th
Non-Stocked item, subject to minimum
quantity.
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
SHIELDED FIRE ALARM CABLE
M.R.
ECOLGICAL
Telecom Cables
DECRIPTION:
• Solid bare copper conductor 18, 16, 14 or 12 AWG
• Semirigid PVC insulation
• Insulated conductors are cabled in all constructions
• Polyester - aluminum foil shield
• Drain wire, stranded 22 or 18 AWG
• PVC Jacket
• FPLR
• Rip-Cord
APPLICATION:
Smoke detectors, burglar alarm,
critical control circuits, power limited
circuits.
Standard lengths of 1000 ft or 500 ft reels
or boxes.
SPECIFICATIONS:
NEC 760 UL-1424 ETL Listed RoHS
Product
Code
Gauge
Number of
Conductors
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
Lb/kft
666571
666573
18
18
2
4
0.010”
0.010”
0.020”
0.020”
0.170”
0.216”
25
39
666581
666582
16
16
2
4
0.010”
0.010”
0.020”
0.020”
0.205”
0.283”
36
56
666585
666586
14
14
2
4
0.013”
0.013”
0.020”
0.020”
0.241”
0.205”
51
82
666590
12
4
0.013”
0.020”
0.260”
66
Voltage
Rating
Conductor
Gauge
AWG
Conductor Resistance
D.C. Maximum
0
Ù/kft @ 20 C
Temperature
Rating
0
C
18
6.40
-200C to 60 C
300 V
16
4.00
0
-200C
60to
C600C
300 V
14
2.56
-200C to 60 C
12
Condumex Wire and Cable
4.00
0
0
0
300 V
0
300 V
-20 C to 60 C
Non-Stocked item, subject to minimum
quantity.
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
8-04
9
RoHS
UNSHIELDED FIRE ALARM CABLE
M.R.
ECOLGICAL
Telecom Cables
PLENUM FIRE ALARM CABLE
DESCRIPTION:
APPLICATION:
Typically used on smoke detectors, fire protective circuits, fire alarms and other
signals used in the fire protection circuits.
Solid bare copper conductors.
Polyvinyl chloride (PVC) smokeguard compound insulation.
Conductors cabled into a core.
Flame retardant PVC somokeguard compound jacket.
Flame test: Plenum as per NFPA 262.
SPECIFICATIONS:
UL-1424
UL-13
UL listed FPLP/CL3P
Quality System ISO-9001
Product Gauge Number of
Code
Conductor
Thickness
Overall
Diameter
Net Weight
14
14
2
4
0.01142
0.01142
0.01575
0.01654
0.1929”
0.2480”
35.614
66.525
667162
667164
16
16
2
4
0.00949
0.00949
0.01378
0.01575
0.1575”
0.2047”
22.847
43.006
667182
667183
18
18
2
3
0.00949
0.00949
0.01378
0.01378
0.136”
0.138”
16.127
22.175
667184
18
4
0.00949
0.01378
0.173”
28.895
Conductor
Gauge
AWG
Conductor Resistance
D.C. Maximum
0
Ù/kft @ 20 C
Temperature
Rating
0
C
Voltage
Rating
14
2.53
75 C
0
300 V
4.02
0
300 V
0
300 V
18
Condumex Wire and Cable
10
Thickness
Jacket
667142
667144
16
8-04
s
Insulation
6.40
75 C
75 C
Standard lengths of 1000 ft or 500 ft reels
or boxes.
2590 114th Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
SHIELDED FIRE ALARM CABLE
M.R.
ECOLGICAL
Telecom Cables
PLENUM SHIELDED FIRE ALARM CABLE
DESCRIPTION:
APPLICATION:
Typically used on smoke detectors, fire protective circuits, fire alarms and other
signals used in the fire protection circuits.
Solid bare copper conductors.
Polyvinyl chloride (PVC) smokeguard compound insulation.
Conductors cabled into a core.
Flame retardant PVC somokeguard compound jacket.
Flame test: Plenum as per NFPA 262.
SPECIFICATIONS:
UL-1424
UL-13
UL listed FPLP/CL3P
Quality System ISO-9001
Product Gauge Number of
Code
Conductor
s
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
667142
667144
14
14
2
4
0.01142
0.01142
0.01575
0.01654
0.1929”
0.2480”
35.614
66.525
667162
667164
16
16
2
4
0.00949
0.00949
0.01378
0.01575
0.1575”
0.2047”
22.847
43.006
Conductor
Gauge
AWG
Conductor Resistance
D.C. Maximum
0
Ù/kft @ 20 C
Temperature
Rating
0
C
Voltage
Rating
14
2.53
75 C
0
300 V
16
4.02
0
75 C
300 V
18
6.40
75 C
0
300 V
Condumex Wire and Cable
Standard lengths of 1000 ft or 500 ft reels
or boxes.
2590 114th Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
8-04
11
RoHS
Voice-Grade Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• 22 or 24 gauge solid bare copper conductor
• PVC insulation
• Insulated conductors twisted into pairs
• PVC Jacket
• CM or CMR
• Operating Temp: -20 C to 75 C
SPECIFICATIONS:
NEC 800 UL-444 RoHS
ANSI/EIA/TIA 568-B.2-1
Standard put-ups are 1000 foot boxes.
FEATURES:
Verified for Category 3 and ETL listed
Product
Code
Gauge
Number of
Pairs
662448*
662451
662459
662462
662464
662467
662471
24
24
24
24
24
24
24
2
3
4
6
8
12
25
662480*
662481
662482
662484
22
22
22
22
2
3
4
6
Insulation
Thickness
Jacket
Thickness
Overall
Diameter
Net Weight
Lb/kft
0.0085”
0.0135”
0.0135”
0.0135”
0.0135”
0.0135”
0.0135”
0.0135”
0.160”
0.176”
0.190”
0.238”
0.269”
0.306“
0.397”
11
15
19
27
30
50
100
0.013”
0.013”
0.013”
0.013”
0.179”
0.197”
0.213”
0.267”
15
20
26
37
* Add SW to part number for special color code (Station Wire) Rd/Gr & Yl/Bk
*All values are nominal,
and subject to
manufacturing tolerances.
Conductor
Resistance
d.c.
Maximum
0
@ 20 C
Nominal
Impedance
Ù
Nominal
Capacitance
1 to 16 MHz
pf/ft
28.6 Ù/kft
100 + 15
20
Transmission Characteristics
Frequency
MHz
Maximum
Attenuation
dB/100 m
Minimum
NEXT loss
dB/100 m
1
4
10
16
2.6
5.6
9.7
13.1
41
32
26
23
Non-Stocked item, subject to minimum
quantity.
Condumex Wire and Cable
9-04
12
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Data-Grade Cables - Cat 5E
PVC CM or CMR Rated 350Mhz
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• 24 gauge solid bare copper conductor
• Polyethylene insulation
• Insulated conductors twisted into pairs
• PVC Jacket
• CMR or CM
• Operating Temp: -20 C to 75 C
FEATURES:
Category 5E and ETL listed, intended
for riser installation.
Standard put-ups are 1000 boxes
SPECIFICATIONS:
NEC 800 RoHS
ANSI/EIA/TIA 568-B.2-1
Product
Code
+
664455
~
664455CM
+
664463
Number
of Pairs
4
4
6
+ CMR Rated Cable
Overall
Diameter
0.189”
0.189”
0.228”
Net Weight
Lb/mft
18
18
25
Jacket
Insulation
Thickness Thickness
0.017”
0.0073”
0.017”
0.0073”
0.017”
0.0073”
~ CM Rated Cable
Conductor
Resistance
d.c.
0
Maximum @ 20 C
Mutual
Capacitance
28.6 Ù/ft
Delay Skew
Maximum
pf/ft
Characteristic
Impedance
Ù
1 to 100 MHz
14
100 + 15
45
Condumex Wire and Cable
ns
Return Loss
Minimal
(fin Mhz)
dB
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-7.0Log(f/20) ; 20<f<100
Frequency
MHz
Transmission Characteristics
Maximum
Minimum
Minimum
Attenuation
NEXT Loss FEXT Loss
dB/100 m
dB/100 m
dB/100 m
4
10
16
31
100
4.1
6.5
8.2
11.7
22.0
56.3
50.3
47.2
42.9
35.3
51.8
43.8
39.7
33.9
23.8
200
250
350
32.4
36.9
44.9
30.8
29.3
27.1
17.8
15.8
12.9
*Typical values, there are no specified values at this frequency in the specification
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
13
RoHS
Data-Grade Cables - Cat 5E
Plenum Rated 350Mhz
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• 24 gauge solid bare copper conductor
• FEP insulation
• Insulated conductors twisted into pairs
• Low smoke PVC Jacket
• CMP
FEATURES:
Category 5E verified and ETL listed,
intended for horizontal, riser and
plenum installation.
Standard put-ups are 1000 boxes
SPECIFICATIONS:
NEC 800 RoHS
ANSI/EIA/TIA 568-B.2-1
Product
Code
664373
Number
of Pairs
4
Conductor
Resistance
d.c.
0
Maximum @ 20 C
Mutual
Capacitance
28.6 Ù/ft
Overall
Diameter
0.195”
Net Weight Jacket Insulation
Lb/mft
Thickness Thickness
21
0.013”
0.0065”
Delay Skew
Maximum
pf/ft
Characteristic
Impedance
Ù
1 to 100 MHz
14
100 + 15
45
ns
Frequency
MHz
Transmission Characteristics
Maximum
Minimum
Minimum
Attenuation
NEXT Loss FEXT Loss
dB/100 m
dB/100 m
dB/100 m
Return Loss
Minimal
(fin Mhz)
dB
4
10
16
31
100
4.1
6.5
8.2
11.7
22.0
56.3
50.3
47.2
42.9
35.3
51.8
43.8
39.7
33.9
23.8
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-7.0Log(f/20) ; 20<f<100
200
250
350
32.4
36.9
44.9
30.8
29.3
27.1
17.8
15.8
12.9
*Typical values, there are no specified values at this frequency in the specification
*All values are nominal,
and subject to
manufacturing tolerances.
Condumex Wire and Cable
2-05
14
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Data-Grade Cables - Cat 5E
CMR Rated 350Mhz
M.R.
ECOLGICAL
Telecom Cables
INSIDE CABLE CATEGORY 5E - STRANDED
*All values are nominal,
and subject to
manufacturing tolerances.
DESCRIPTION:
• 24 gauge stranded bare copper conductor
• Polyethylene insulation
• Insulated conductors twisted into pairs
• PVC Jacket
• CM or CMR
FEATURES:
Category 5E verified and ETL listed
Standard put-ups are 1000 foot reels,
boxes and reel-in-a-box.
SPECIFICATIONS:
NEC 800,CM rated
ANSI/EIA/TIA 568-B.2-1
RoHS
Product
Code
Number
of Pairs
Conductor
Construction
Wires/AWG
Overall
Diameter
664555
4
7/32
0.217”
Conductor
Resistance
d.c.
0
Maximum @ 20 C
Mutual
Capacitance
28.6 Ù/ft
Net Weight Jacket Insulation
Lb/mft
Thickness Thickness
24
Delay Skew
Maximum
pf/ft
Characteristic
Impedance
Ù
1 to 100 MHz
14
100 + 15
45
ns
Transmission Characteristics
Frequency
MHz
Maximum
Attenuation
dB/100 m
Minimum
NEXT Loss
dB/100 m
Return Loss
Minimal
(fin Mhz)
dB
4
10
16
31
100
4.9
7.8
9.9
14.1
26.4
56.3
50.3
47.2
42.9
35.3
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-8.6Log(f/20) ; 20<f<100
200*
250*
350*
38.9
44.2
53.8
30.8
29.3
27.1
0.020”
0.0071”
*Typical values, there are no specified values at this frequency in the specification
Non-Stocked item, subject to minimum
quantity.
Condumex Wire and Cable
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
15
RoHS
Shielded Data-Grade Cables - Cat 5E
CMR Rated 350Mhz
M.R.
ECOLGICAL
Telecom Cables
INSIDE CABLE CATEGORY 5E - SHIELDED
DESCRIPTION:
• 24 gauge solid bare copper conductor
• Polyethylene insulation
• Insulated conductors twisted into pairs
• Tinned copper drain wire
• Foil Shield
• -10 C to 60 C
• PVC Jacket
• CM or CMR
Product
Code
664405
Number
of Pairs
4
Overall
Diameter
0.276”
Net Weight
Lb/mft
30
Delay Skew
Maximum
pf/ft
Characteristic
Impedance
Ù
1 to 100 MHz
14
100 + 15
45
Conductor
Resistance
d.c.
0
Maximum @ 20 C
Mutual
Capacitance
28.6 Ù/ft
ns
Jacket
Insulation
Thickness Thickness
0.024”
0.010”
Return Loss
Minimal
(fin Mhz)
dB
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-7.0Log(f/20) ; 20<f<100
FEATURES:
Category 5E and ETL listed
SPECIFICATIONS:
CMR Rated, ISO/IEC 11801
ANSI/EIA/TIA 568-B.2-1
RoHS
Standard put-ups are 1000 foot reels.
Frequency
MHz
Transmission Characteristics
Maximum
Minimum
Minimum
Attenuation
NEXT Loss FEXT Loss
dB/100 m
dB/100 m
dB/100 m
4
10
16
31
100
4.1
6.5
8.2
11.7
22.0
56.3
50.3
47.2
42.9
35.3
51.8
43.8
39.7
33.9
23.8
200
250
350
32.4
36.9
44.9
30.8
29.3
27.1
17.8
15.8
12.9
*Typical values, there are no specified values at this frequency in the specification
Condumex Wire and Cable
2-05
16
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Data-Grade Cables - Cat 5E+
CMR Rated 400Mhz
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• 24 gauge solid bare copper conductor
• Polyethylene insulation
• Insulated conductors twisted into pairs
• PVC Jacket
• CM orCMR
FEATURES:
Category 5E and ETL listed, intended
for horizontal installation.
Standard put-ups are 1000 foot boxes
SPECIFICATIONS:
NEC 800 RoHS
ANSI/EIA/TIA 568-B.2-1
Product
Code
664455A
Number
of Pairs
4
Overall
Diameter
0.190”
Net Weight Jacket Insulation
Lb/mft
Thickness Thickness
18
0.017”
0.0073”
Delay Skew
Maximum
pf/ft
Characteristic
Impedance
Ù
1 to 100 MHz
14
100 + 15
45
Conductor
Resistance
d.c.
0
Maximum @ 20 C
Mutual
Capacitance
28.6 Ù/ft
ns
Frequency
MHz
Return Loss
Minimal
(fin Mhz)
dB
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-7.0Log(f/20) ; 20<f<100
Transmission Characteristics
Maximum
Minimum
Minimum
Attenuation
NEXT Loss FEXT Loss
dB/100 m
dB/100 m
dB/100 m
1
10
16
31
100
2.1
6.5
8.2
11.7
22.0
65.3
50.3
47.2
42.9
35.3
63.8
43.8
39.7
33.9
23.8
200*
250*
350*
400*
32.4
36.9
44.9
48.5
30.8
29.3
27.1
26.3
17.8
15.8
12.9
11.8
*Typical values, there are no specified values at this frequency in the specification
Non-Stocked item, subject to minimum
quantity.
Condumex Wire and Cable
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
17
RoHS
Data-Grade Cables - Cat 5E+
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• 24 gauge solid bare copper conductor
• Polyethylene insulation
• Insulated conductors twisted into pairs
• Core filled with water blocking gel
• Polyethylene Jacket
FEATURES:
Category 5E intended for structured
cabling in telecommunications networks,
for outdoor use in direct burial or
duct installations.
Standard put-ups are 1000 foot boxes
SPECIFICATIONS:
ISO/IEC 11801 RoHS
ANSI/EIA/TIA 568-B.2-1
Product
Code
664455DB
Conductor
Resistance
d.c.
0
Maximum @ 20 C
Number
of Pairs
4
Mutual
Capacitance
pf/ft
28.6 Ù/ft
16
Overall
Diameter
0.225”
Characteristic
Impedance
Ù
1 to 100 MHz
100 + 15
(1-100MHz)
100 ± 22
(100-200MHz)
Net Weight Jacket
Lb/mft
Thickness
18
0.0205”
Delay Skew
Maximum
ns
45
Frequency
MHz
Return Loss
Minimal
(fin Mhz)
dB
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-7.0Log(f/20) ; 20<f<100
*All values are nominal,
and subject to
manufacturing tolerances.
Condumex Wire and Cable
2-05
18
Transmission Characteristics
Maximum
Minimum
Minimum
Attenuation
NEXT Loss FEXT Loss
dB/100 m
dB/100 m
dB/100 m
1
10
16
31
100
2.1
6.5
8.2
11.7
22.0
65.3
50.3
47.2
42.9
35.3
63.8
43.8
39.7
33.9
23.8
200*
250*
350*
400*
32.4
36.9
44.9
48.5
30.8
29.3
27.1
26.3
17.8
15.8
12.9
11.8
*Typical values, there are no specified values at this frequency in the specification
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Data-Grade Cables - Cat 6
CMR Rated 250Mhz
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• 23 gauge solid bare copper conductor
• Polyethylene insulation
• Insulated conductors twisted into pairs
• PVC Jacket
• Polyethylene crossweb to separate the pairs
• CM or CMR
FEATURES:
Category 6 verified and UL and ETL
listed, intended for horizontal installation.
Standard put-ups are 1000
reel-in-a-box.
SPECIFICATIONS:
NEC 800 UL-444 RoHS
ANSI/EIA/TIA 568-B.2-1
Product
Code
664466
Conductor
Resistance
d.c.
0
Maximum @ 20 C
26 Ù/ft
Number
of Pairs
4
Mutual
Capacitance
Overall
Diameter
0.244”
Characteristic
Impedance
Delay Skew
Maximum
Ù
ns
pf/ft
16.8
Net Weight Jacket Insulation
Lb/mft
Thickness Thickness
26
0.017”
0.009”
100 + 15
(1 - 100 MHz)
100 + 22
(100 - 200 MHz)
100 + 32
(200 to 250 MHz)
Condumex Wire and Cable
45
Return Loss
Minimal
(fin MHz)
dB
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-7.0Log(f/20) ; 20<f<250
Frequency
MHz
Transmission Characteristics
Maximum
Minimum
Attenuation
NEXT Loss
dB/100 m
dB/100 m
Minimum
FEXT Loss
dB/100 m
10
16
31
100
200
250
6.0
7.7
10.7
19.8
29.0
32.8
59.3
36.2
51.9
44.3
39.8
38.3
47.8
43.2
37.9
27.8
21.8
19.8
350*
39.8
36.1
16.9
*Typical values, there are no specified values at this frequency in the specification
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
1-06
19
RoHS
Data-Grade Cables - Cat 6
CMP Rated 250Mhz
M.R.
ECOLGICAL
Telecom Cables
*All values are nominal,
and subject to
manufacturing tolerances.
DESCRIPTION:
• 23 gauge solid bare copper conductor
• FEP insulation
• Insulated conductors twisted into pairs
• Plenum rated PVC Jacket
• Polyethylene crossweb to separate the pairs
• CMP
SPECIFICATIONS:
ISO/IEC 11801 (2002)
ANSI/EIA/TIA 568-B.2-1
RoHS
Product
Code
664866
Number
of Pairs
4
Overall
Diameter
0.232”
Mutual
Capacitance
Characteristic
Impedance
Delay Skew
Maximum
pf/ft
Ù
ns
26 Ù/ft
16.8
100 + 15
(1 - 100 MHz)
100 + 22
(100 - 200 MHz)
100 + 32
(200 to 250 MHz)
Condumex Wire and Cable
1-06
20
45
Standard put-ups are 1000
reel-in-a-box.
UL-444: MPP
NEMA WC 66
Net Weight Jacket
Lb/mft
Thickness
28
0.014”
Conductor
Resistance
d.c.
0
Maximum @ 20 C
FEATURES:
Category 6 verified and UL and ETL
listed, intended for horizontal installation.
Return Loss
Minimal
(fin MHz)
dB
20+5Log(f) ; 1<f<10
25 ; 10<f<20
25-7.0Log(f/20) ; 20<f<250
Frequency
MHz
Transmission Characteristics
Maximum
Minimum
Attenuation
NEXT Loss
dB/100 m
dB/100 m
Minimum
FEXT Loss
dB/100 m
10
16
31
100
200
250
6.0
7.7
10.7
19.8
29.0
32.8
59.3
36.2
51.9
44.3
39.8
38.3
47.8
43.2
37.9
27.8
21.8
19.8
350*
39.8
36.1
16.9
*Typical values, there are no specified values at this frequency in the specification
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of solid copper wire
• Gas injected foamed polyethylene insulation
• Braid of copper wires
• Black PVC jacket
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
CM or CL2 ETL Listed
NEC 725/800 RoHS
Standard lengths of 1000 ft boxes
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
801426
811428
20 AWG
20 AWG
0.144”
0.144”
0.242”
0.242”
95%
95%
31
31
Impedance
Ù
*All values are nominal,
and subject to
manufacturing tolerances.
75 + 5
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
10.34
81
16
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
1.22
2.06
3.94
4.72
5.83
6.47
7.62
8.24
8.87
COAXIAL CABLE RG 6/U BC - 95% BC BRAID
DESCRIPTION:
• Conductor of solid copper wire
• Gas injected foamed polyethylene insulation
• Braid of copper wires
• Black PVC jacket
Standard stock lengths of 1000 ft boxes
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
CM or CL2 ETL Listed
NEC 725/800 RoHS
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
809145
18 AWG
0.180”
0.268”
95%
42
Impedance
Ù
75 + 5
Condumex Wire and Cable
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
6.37
81
16
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
0.81
1.60
3.08
3.70
4.56
5.09
6.00
6.50
7.00
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
21
RoHS
RG-59U - Plenum Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
COAXIAL CABLE RG 59/U BC - 95% BC BRAID - PLENUM RATED
DESCRIPTION:
• Conductor of solid copper wire
• Foamed fluorinated ethylene propylene insulation
• Braid of copper wires
• Low Smoke White PVC jacket
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
NEC Type CMP
RoHS
Standard lengths of 1000 ft reels
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
801426FEP
20 AWG
0.135”
0.193”
95%
35
Impedance
Ù
*All values are nominal,
and subject to
manufacturing tolerances.
75
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
10.0
75
16.1
* Minimum order
quantity required.
Condumex Wire and Cable
5-05
22
th
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
0.89
1.95
3.59
4.27
5.30
5.90
6.96
7.54
8.09
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
RG-6U - Plenum Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
COAXIAL CABLE RG 6/U BC - 95% BC BRAID - PLENUM RATED
DESCRIPTION:
• Conductor of solid copper wire
• Foamed fluorinated ethylene propylene insulation
• Braid of copper wires
• Low Smoke White PVC jacket
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
NEC Type CMP
RoHS
Standard lengths of 1000 ft reels
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
809146FEP
18 AWG
0.170”
0.233”
95%
42
Impedance
Ù
75
Conductor
Resistance
0
@ 20 C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
6.4
83
16.3
* Minimum order
quantity required.
Condumex Wire and Cable
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
0.67
1.60
2.87
3.43
4.26
4.71
5.59
6.00
6.54
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
5-05
23
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of copper clad steel
• Gas injected polyolefin insulation
• Polyester - aluminum foil, adhered to the
insulation
• Braid of aluminum wires
• PVC jacket
PROPERTIES:
High speed of propagation.
SPECIFICATIONS:
UL-444 RoHS
SCTE IPS SP 001
NEC 800/825
CM or CATV ETL Listed
Standard lengths of 1000 ft reels.
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
807520
14 AWG
0.28”
0.397”
60%
61
Impedance
Ù
*All values are nominal,
and subject to
manufacturing tolerances.
75
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
12.9
82
16
Non-Stocked item, subject to minimum
quantity.
Condumex Wire and Cable
5-05
24
th
Attenuation
dB/100 ft
Frequency
MHz
Maximum
250
500
750
1000
1200
1540
1800
2200
2.20
3.19
3.99
4.67
4.93
5.69
6.24
7.03
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of copper clad steel
• Gas injected foamed polyethylene
• Polyester - aluminum foil, adhered to the
insulation
• Braid of aluminum wires
• Water-block flooding compound
• Black linear low density polyethylene
PROPERTIES:
High speed of propagation.
SPECIFICATIONS:
UL-444 RoHS
SCTE IPS SP 001
NEC 800/825
CM or CATV ETL Listed
Standard lengths of 1000 ft or 500 ft reels.
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
TBD
14 AWG
0.28”
0.397”
60%
52
Impedance
Ù
75
Conductor
Resistance
0
@ 20 C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
12.9
82
16
Attenuation
dB/100 ft
Frequency
MHz
Maximum
250
500
750
1000
1200
1540
1800
2200
2.20
3.19
3.99
4.67
4.93
5.69
6.24
7.03
Non-Stocked item, subject to minimum
quantity.
Condumex Wire and Cable
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
5-05
25
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of bare copper
• Solid polyethylene insulation
• Braid of tinned copper wires
• PVC jacket
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
UL-13 RoHS
CL2 ETL Listed
Standard lengths of 1000 ft reels
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
809940
20 AWG
0.116”
0.195”
95%
26
Non-Stocked item, subject to minimum
quantity.
*All values are nominal,
and subject to
manufacturing tolerances.
Condumex Wire and Cable
2-05
26
Impedance
Ù
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
5
Nominal
Capacitance
pF/ft
50 + 5
10.34
66
30
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of stranded, tinned copper
• Solid polyethylene insulation
• Braid of tinned copper wires
• PVC jacket
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
UL-13 RoHS
CL2 ETL Listed
Standard lengths of 1000 ft or 500 ft
reels or boxes.
Product
Code
Conductor
Diameter
Conductor
Construction
Wires/AWG
Insulation
Diameter
Overall
Diameter
Braid
Coverage
Net
Weight
Lb/kft
800116
20 AWG
19 x 33 AWG
0.116”
0.195”
95%
26
Impedance
Ù
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
12.35
29
66
50 + 5
Non-Stocked item, subject to minimum
quantity.
Condumex Wire and Cable
Attenuation
dB/100 ft
Frequency
MHz
100
400
1000
1800
2000
Maximum
4.28
9.32
16.58
25.07
27.16
*All values are nominal,
and subject to
manufacturing tolerances.
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
27
RoHS
Rg6U PVC Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of copper clad steel
• Gas injected foamed polyethylene insulation
• Polyester - aluminum foil, adhered to the
insulation
• Braid of aluminum wires
• PVC jacket
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
UL-444, NEC 800/820
SCTE-IPS-SP-001 RoHS
CM or CATV ETL listed
Standard lengths of 1000 ft boxes
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
809114
18 AWG
0.180”
0.264”
40%
Impedance
Ù
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
32
81
16
75 + 5
Non-Stocked item, subject to minimum
quantity.
Condumex Wire and Cable
2-05
28
Net
Weight
Lb/kft
26
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
0.81
1.60
3.08
3.70
4.58
5.09
6.00
6.50
7.00
*All values are nominal,
and subject to
manufacturing tolerances.
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Rg6U PVC Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of copper clad steel
• Gas injected foamed polyethylene insulation
• Polyester - aluminum foil, adhered to the
insulation
• Braid of aluminum wires
• PVC jacket
• Operating Temp: -20 C to 60 C
PROPERTIES:
Flexible high speed of propagation.
SPECIFICATIONS:
UL-444, NEC 800/820
SCTE-IPS-SP-001 RoHS
CM or CATV ETL listed
Standard lengths of 1000 ft reels or boxes
500 ft boxes
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
809116R
18 AWG
0.139”
0.226”
60%
Impedance
Ù
Conductor
Resistance
0
@ 20 C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
39.04
82
16.18
75 + 3
Condumex Wire and Cable
Net
Weight
Lb/kft
29.42
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
870
1250
2200
3000
0.81
1.60
3.08
3.70
4.58
6.50
7.62
9.49
11.54
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
29
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of copper clad steel
• Gas injected foamed polyethylene insulation
• Polyester - aluminum foil, adhered to the insulation
• Inner braid of aluminum wires
• Overlapped aluminum - polyester - aluminum foil,
• Outer braid of aluminum wires
• PVC jacket
*All values are nominal,
and subject to
manufacturing tolerances.
30
SPECIFICATIONS:
UL-444, NEC 800/820
SCTE-IPS-SP-001 RoHS
CM or CATV ETL Listed
Standard lengths of 1000 ft or 500 ft
reels or 500 ft boxes.
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
801189
18 AWG
0.180”
0.291”
1st Layer: 60%
2nd Layer: 40%
Impedance
Ù
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
32
81
16
75 + 5
Condumex Wire and Cable
2-05
PROPERTIES:
Flexible, high speed of propagation.
th
Net
Weight
Lb/kft
30
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
0.81
1.60
3.08
3.70
4.58
5.09
6.00
6.50
7.00
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of bare copper
• Gas injected foamed polyethylene insulation
• Polyester - aluminum foil, adhered to the insulation
• Inner braid of alumium wires
• Overlaped aluminum - polyester - aluminum foil,
• Outer braid of alumium wires
• PVC jacket
*All values are nominal,
and subject to
manufacturing tolerances.
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
UL-444, NEC 800/820
SCTE-IPS-SP-001 RoHS
CM or CATV ETL Listed
Standard lengths of 1000 ft or 500 ft
reels or 500 ft boxes.
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
801189DSS
18 AWG
0.180”
0.291”
1st Layer: 60%
2nd Layer: 40%
Impedance
Ù
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
6.4
81
16
75 + 5
Condumex Wire and Cable
Net
Weight
Lb/kft
33
Attenuation
dB/100 ft
Frequency
MHz
Maximum
1
10
50
100
200
400
700
900
1000
1200
1450
1800
2200
0.25
0.70
1.46
1.95
2.73
3.80
5.20
5.90
6.30
6.80
7.60
8.20
9.80
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
9-04
31
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
COAXIAL CABLE RG 6/U - 60% BRAID - PLENUM RATED
DESCRIPTION:
• Conductor of copper clad steel
• Foamed fluorinated ethylene propylene insulation
• Polyester - aluminum foil, adhered to the
insulation
• Braid of aluminum wires
• Low smoke PVC jacket
PROPERTIES:
Flexible high speed of propagation.
SPECIFICATIONS:
NEC Type CMP
RoHS
Standard lengths of 1000 ft or 500 ft
reels or boxes.
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
809116FEP
18 AWG
0.170”
0.235”
60%
Impedance
Ù
75
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
28
83
16.3
*All values are nominal,
and subject to
manufacturing tolerances.
* Minimum order
quantity required.
Net
Weight
Lb/kft
24
Attenuation
dB/100 ft
Frequency
MHz
5
55
211
300
450
550
750
870
1000
Maximum
0.67
1.60
2.87
3.43
4.26
4.71
5.59
6.00
6.54
COAXIAL CABLE RG 6/U - QUAD SHIELD - PLENUM RATED
DESCRIPTION:
• Conductor of copper clad steel
• Foamed fluorinated ethylene propylene insulation
• Polyester - aluminum foil, adhered to the insulation
• Inner braid of aluminum wires
• Overlapped aluminum - polyester - aluminum foil,
• Outer braid of aluminum wires
• Low smoke PVC jacket
Standard lengths of 1000 ft or 500 ft
reels or 500 ft boxes.
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
801289FEP
18 AWG
0.170”
0.248”
1st Layer: 60%
2nd Layer: 40%
Impedance
Ù
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
28
83
16.3
* Minimum order
quantity required.
Condumex Wire and Cable
32
SPECIFICATIONS:
NEC Type CMP
RoHS
Product
Code
75
5-05
PROPERTIES:
Flexible, high speed of propagation.
th
Net
Weight
Lb/kft
34
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
0.67
1.60
2.87
3.43
4.26
4.71
5.59
6.00
6.54
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Coaxial Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
• Conductor of copper clad steel
• Gas injected foamed polyethylene insulation
• Polyester - aluminum foil, adhered to the
insulation
• Braid of aluminum wires
• PVC jacket
PROPERTIES:
Flexible high speed of propagation.
SPECIFICATIONS:
UL-444, NEC 800/820
SCTE-IPS-SP-001 RoHS
CM or CATV ETL listed
Standard lengths of 1000 ft or 500 ft
reels.
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
809220
18 AWG
0.180”
(2 x) 0.264”
60%
Impedance
Ù
Conductor
Resistance
0
@ 20 C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
32
81
16
75 + 5
*All values are nominal,
and subject to
manufacturing tolerances.
DESCRIPTION:
• Conductor of copper clad steel
• Gas injected foamed polyethylene insulation
• Polyester - aluminum foil, adhered to the insulation
• Inner braid of aluminum wires
• Overlapped aluminum - polyester - aluminum foil,
• Outer braid of aluminum wires
• PVC jacket
Attenuation
dB/100 ft
Frequency
MHz
Maximum
5
55
211
300
450
550
750
870
1000
0.81
1.60
3.08
3.70
4.58
5.09
6.00
6.50
7.00
PROPERTIES:
Flexible, high speed of propagation.
SPECIFICATIONS:
UL-444, NEC 800/820
SCTE-IPS-SP-001 RoHS
CM or CATV ETL listed
Standard lengths of 1000 ft or 500 ft
reels.
Product
Code
Conductor
Diameter
Insulation
Diameter
Overall
Diameter
Braid
Coverage
809221
18 AWG
0.180”
(2 x) 0.291”
1st Layer: 60%
2nd Layer: 40%
Impedance
Ù
75 + 5
Condumex Wire and Cable
Conductor
Resistance
@ 200C
Ù/kft
Propagation
Speed
Nominal
Capacitance
%
pF/ft
6.4
83
16
Net
Weight
Lb/kft
50
Net
Weight
Lb/kft
70
Attenuation
dB/100 ft
Frequency
MHz
Maximum
1
10
50
100
200
400
700
900
1000
1200
1450
1800
2200
0.25
0.70
1.46
1.95
2.73
3.80
5.20
5.90
6.30
6.80
7.60
8.20
9.80
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
2-05
33
RoHS
Home Control Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
One RG 59/U BC - 95% BC braid cable and one stranded 18 AWG 2 conductor cable
PROPERTIES:
1One RG 59/U cable:
• 20 AWG bare copper center conductor
• Gas-injected foamed polyethylene insulation
• 95% bare copper braid
• PVC jacket
18 AWG Cable Properties
Number of
Insulation
Jacket
Conductors Thickness Thickness
2
0.009”
0.0135”
RG 59/U Cable Properties
Insulation
Conductor
Diameter
Diameter
AWG
20
Product
Code
Overall
Diameter
820148
0.487 x 0.308”
1One, 18 AWG, 2 Conductor cable:
• Stranded bare copper conductors
• Semirigid PVC insulation
• PVC jacket
1Overall PVC jacket
Net
Weight
Lb/kft
74
SPECIFICATIONS:
NEC 800 RoHS
Overall
Diameter
Conductor
Gauge
AWG
Conductor
Construction
Wires/AWG
Conductor Resistance
D.C. Maximum
0
Ù/kft @ 20 C
Temperature
Rating
0
60 C
Voltage
Rating
0.148
18
19/31
6.55
60
300 V
Overall
Diameter
Braid
Coverage
Impedance
Ù
Conductor
Resistance
0
@ 20 C
Ù/kft
Propagation
Speed
%
Nominal
Capacitance
pF/ft
0.232”
95%
75 + 5
10.34
81
16
0.144”
*All values are nominal,
and subject to
manufacturing tolerances.
DESCRIPTION:
One RG 59/U BC - 95% BC braid cable and two stranded 18 AWG wires
DESCRIPTION:
1One RG 59/U cable:
• 20 AWG bare copper center conductor
• Gas-injected foamed polyethylene insulation
• 95% bare copper braid
• PVC jacket
18 AWG Wire Properties
Insulation
Overall
Thickness
Diameter
0.009”
0.063
RG 59/U Cable Properties
Insulation
Conductor
Diameter
Diameter
AWG
20
0.144”
Condumex Wire and Cable
2-05
34
Product
Code
Overall
Diameter
820149X
0.336 x 0.455”
1Two,18 AWG wires:
• Stranded bare copper conductors
• Semirigid PVC insulation
1Overall PVC jacket
SPECIFICATIONS:
NEC 800
RoHS
Net
Weight
Lb/kft
71
Conductor
Gauge
AWG
Conductor
Construction
Wires/AWG
Conductor Resistance
D.C. Maximum
0
Ù/kft @ 20 C
Temperature
Rating
600C
Voltage
Rating
18
19/31
6.55
600C
300 V
Overall
Diameter
Braid
Coverage
Impedance
Ù
Conductor
Resistance
0
@ 20 C
Ù/kft
Propagation
Speed
%
Nominal
Capacitance
pF/ft
0.232”
95%
75 + 5
10.34
81
16
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Home Control Cables
M.R.
ECOLGICAL
Telecom Cables
COMPOSITE CABLE - RG 6/U + 18/2
DESCRIPTION:
One RG 6/U BC - 95% BC braid cable and one stranded 18 AWG 2 conductor cable
PROPERTIES:
1One RG 6/U cable:
• 18 AWG bare copper center conductor
• Gas-injected foamed polyethylene insulation
• 95% bare copper braid
• PVC jacket
Product
Code
Overall
Diameter
2
0.0155”
RG 6/U Cable Properties
Conductor
Conductor
Diameter
Diameter
AWG
18
0.040”
• Stranded bare copper conductors
• Polypropylene insulation
• PVC jacket
Net
Weight
Lb/kft
59
820081SIM 0.264 x 0.485”
18 AWG Cable Properties
Number of
Insulation
Conductors
Thickness
1One, 18 AWG, 2 Conductor cable:
1Siamese construction
SPECIFICATIONS:
NEC 800 RoHS
UL PVC 75OC
*All values are nominal,
and subject to
manufacturing tolerances.
Conductor
Diameter
Conductor
Gauge
AWG
Conductor
Construction
Wires/AWG
Temperature
Rating
0
C
Voltage
Rating
0.046”
18
16/30
75
300 V
Insulation
Thickness
Overall
Diameter
Insulation
Braid
Coverage
Impedance
Ù
Nominal
Capacitance
pF/ft
0.070”
0.178 + .006”
95%
75 + 3
16.3
COMPOSITE CABLE - RG 59+ 18/2
DESCRIPTION:
One RG 59BC - 95% BC braid cable and one stranded 18 AWG 2 conductor cable
PROPERTIES:
1One RG 6/U cable:
• 20 AWG bare copper center conductor
• Gas-injected foamed polyethylene insulation
• 95% bare copper braid
• PVC jacket
Product
Code
Overall
Diameter
2
0.0091”
RG 6/U Cable Properties
Conductor
Conductor
Diameter
Diameter
AWG
20
0.032”
Condumex Wire and Cable
• Stranded bare copper conductors
• Polypropylene insulation
• PVC jacket
Net
Weight
Lb/kft
59
820150SIM 0.264 x 0.485”
18 AWG Cable Properties
Number of
Insulation
Conductors
Thickness
1One, 18 AWG, 2 Conductor cable:
1Siamese construction
SPECIFICATIONS:
UL-1655 RoHS
UL -13
*All values are nominal,
and subject to
manufacturing tolerances.
Conductor
Diameter
Conductor
Gauge
AWG
Conductor
Construction
Wires/AWG
Temperature
Rating
0
C
Voltage
Rating
0.043”
18
16/18
75
300 V
Insulation
Thickness
Overall
Diameter
Insulation
Braid
Coverage
Impedance
Ù
Nominal
Capacitance
pF/ft
0.056”
0.144 + .006”
95%
75 + 3
16.3
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
4-05
35
RoHS
Home Control Cables
M.R.
ECOLGICAL
Telecom Cables
DESCRIPTION:
1Two RG 6/U Quad cables:
• 18 AWG copper clad steel center conductor
• Gas-injected foamed polyethylene insulation
1Two, 4-pair, Cat 5e cables
• Solid copper conductors
• Polyethylene insulation
APPLICATION:
Residential Cabling with structured design for voice,
data, video and any other high-speed application.
PROPERTIES:
19 mm
Overall Diameter:
250 lbs
Cable Weight per 1,000 feet:
RoHS
Standard lengths of 500 foot reels
1Overall PVC jacket
Product Conductor Conductor
Code
Diameter Resistance
TBD
18 AWG
Insulation
Diameter
Braid
Coverage
Impedance
4.5 mm
60% - 40%
75 + 3Ù
105 Ù/km
Conductor
Diameter
Number
of Paris
Conductor
Resistance
Impedance
24 AWG
4
90.5 Ù/km
100 + 15
Capacitance
52 pF/m
Mutual
Capacitance
45.9 pF/m
*All values are nominal,
and subject to
manufacturing tolerances.
Propagation
Speed
81%
Attenuation
MHz
55
211
300
550
750
1000
dB/100 m
5.3
10.0
11.7
16.1
18.6
21.5
Properties at 100 m
Frequency Attenuation PSNext
MHz
dB/100 m
dB/100
4
10
16
62.5
100
4.1
6.5
8.2
17.0
22.0
53.3
42.3
44.2
35.4
32.3
DESCRIPTION:
APPLICATION:
1Two RG 6/U Quad cables:
Residential Cabling with structured design for voice,
• 18 AWG copper clad steel center conductor
data, video and any other high-speed application.
• Gas-injected foamed polyethylene insulation.
PROPERTIES:
1Two, 4-pair, Cat 5e cables
1Two, 62.5µ Multimode Fibers
19 mm
Overall Diameter:
• Solid copper conductors
• Overall PVC jacket
255 lbs
Cable Weight per 1,000 feet:
• Tight-buffered
• Polyethylene insulation
Standard lengths of 500 foot reels
distribution construction
1Overall PVC jacket
RoHS
Product Conductor Conductor
Code
Diameter Resistance
TBD
18 AWG
36
Braid
Coverage
Impedance
4.5 mm
60% - 40%
75 + 3Ù
105 Ù/km
Conductor
Diameter
Number
of Paris
Conductor
Resistance
Impedance
24 AWG
4
90.5 Ù/km
100 + 15
Capacitance
52 pF/m
Mutual
Capacitance
45.9 pF/m
Number
of Fibers
Core
Diameter
Cladding
Diameter
Minimum
Bend Radius
2
62.5 + 3 µm
125 + 2 µm
60 mm
Condumex Wire and Cable
4-05
Insulation
Diameter
th
Propagation
Speed
81%
Attenuation
MHz
55
211
300
550
750
1000
dB/100 m
5.3
10.0
11.7
16.1
18.6
21.5
Properties at 100 m
Frequency Attenuation PSNext
MHz
dB/100 m
dB/100
4
10
16
62.5
100
4.1
6.5
8.2
17.0
22.0
53.3
47.3
44.2
35.4
32.3
Attenuation
3.2 dB/km @ 850 nm
0.9 dB/km @ 1300 nm
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
RoHS
Home Control Cables
M.R.
ECOLGICAL
Telecom Cables
COMPOSITE CABLE - RG 6/U CABLE + CAT 5E SIAMESE
DESCRIPTION:
1One RG 6/U Quad cable:
• 18 AWG bare copper center conductor
• Gas-injected foamed polyethylene insulation
1One, 4-pair, Cat 5E cable
• Solid copper conductors
• Polyethylene insulation
1Siamese construction
APPLICATION:
Residential Cabling with structured design for voice,
data, video and any other high-speed application.
PROPERTIES:
0.525 x 0.3”
Overall Diameter:
Cable Weight per 1,000 feet:
55 lbs.
RoHS
Standard lengths of 500 foot reels
Braid
Propagation
Resistance
r
Product
Speed
Diameter Insulation Coverage Capacitance
Code
Conducto Conductor Diameter Impedance
821005
*All values are nominal,
and subject to
manufacturing tolerances.
18 AWG
4.5 mm
38 Ù/km
60% - 40%
75 + 3Ù
Conductor
Diameter
Number
of Pairs
Conductor
Resistance
Impedance
24 AWG
4
93.8 Ù/km
100 + 15Ù
Attenuation
52.0 pF/m
Pair-to-Pair
Capacitance
Unbalance
< 330 pF/100 m
81%
MHz
dB/100 m
55
211
300
550
750
1000
5.3
10.0
11.7
16.1
18.6
21.5
Properties at 100 m
Frequency Attenuation PSNext
MHz
dB/100 m dB/100ft
4.1
4
53.3
10
6.5
47.3
16
8.2
44.3
62.5
17.0
35.4
100
22.0
32.3
COMPOSITE CABLE - 2 X RG 6/U CABLE + CAT 5E TRIAMESE
DESCRIPTION:
1Two RG 6/U Quad cables:
• 18 AWG bare copper center conductor
• Gas-injected foamed polyethylene insulation
1One, 4-pair, Cat 5E cable
• Solid copper conductors
• Polyethylene insulation
1Triamese construction
APPLICATION:
Residential Cabling with structured design for voice,
data, video and any other high-speed application.
PROPERTIES:
Overall Diameter:
0.823 x 0.3”
Cable Weight per 1,000 feet:
90 lbs
RoHS
Standard lengths of 500 foot reels
Braid
Propagation
Resistance
or
Product
Coverage Capacitance
Speed
Diameter Insulation
Code
Conduct Conductor Diameter Impedance
820146
18 AWG
99.5 Ù/km
4.57 mm
60% - 40%
75 + 3Ù
Conductor
Diameter
Number
of Pairs
Conductor
Resistance
Impedance
24 AWG
4
93.8 Ù/km
100 + 15Ù
Condumex Wire and Cable
Attenuation
53.1 pF/m
Pair-to-Pair
Capacitance
Unbalance
< 330 pF/100 m
82%
MHz
dB/100 m
55
211
300
550
750
1000
5.25
10.10
12.14
16.70
19.69
22.97
Properties at 100 m
Frequency Attenuation PSNext
MHz
dB/100 m dB/100ft
53.3
4.1
4
47.3
6.5
10
44.3
8.2
16
35.4
17.0
62.5
32.3
22.0
100
th
2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473
4-05
37
NOTES:
Condumex Wire and Cable
5-05
2590 114th Street, #200 - Grand Prairie, TX 75050 (800) 925-9473
www.condumexinc.com