Cables - Condumex Inc.
Transcription
Cables - Condumex Inc.
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA , C O A X I A L , A N D EL E CTRON I C ECOLGICAL Telecom Cables Cables RoHS M.R. Index ECOLGICAL Telecom Cables 2 3-5 6 7 8-11 12 13-16 17-18 19-20 21-33 34-37 • SOLID MULTI-CONDUCTOR CABLES • STRANDED MULTI-CONDUCTOR CABLES • SPEAKER/ZIP WIRE • THERMOSTAT CABLE • FIRE ALARM CABLE • CATEGORY 3 CABLE • BRAVOTWIST™ CATEGORY 5E • BRAVOTWIST™ CATEGORY 5E+ • BRAVOTWIST™ CATEGORY 6 • COAXIAL CABLE • COMPOSITE/HOME CONTROL CABLES Condumex Wire and Cable 5-05 1 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Solid - Unshielded Multi-Conductor Cable M.R. ECOLGICAL Telecom Cables SOLID MULTI-CONDUCTOR CABLE DECRIPTION: • Solid bare copper conductor 24 or 22 AWG • Semirigid PVC insulation • PVC Jacket SPECIFICATIONS: NEC 800 UL-444 ETL Listed CMR or CL2R Product Code 631737 Gauge 631722 631724 631726 631728 631731 Standard stocked lengths of 1000 ft or 500 ft, in coil packs or pull boxes. NEC 725 RoHS 24 Number of Conductors 4 Insulation Thickness 0.006” Jacket Thickness 0.0135” Overall Diameter 0.110” Net Weight Lb/mft 9 22 22 22 22 22 2 4 6 11 12 0.006” 0.006” 0.006” 0.006” 0.006” 0.0135” 0.0135” 0.0135” 0.0135” 0.0135” 0.105” 0.124” 0.148” 0.170” 0.186” 7 12 18 22 32 Conductor Gauge AWG Conductor Resistance D.C. Maximum Ù/kft 200C Temperature Rating 24 26.80 60 C 22 APPLICATION: Burglar alarm, audio control systems, limited circuits. 17.60 Voltage Rating 0 300 V 0 300 V 60 C *All values are nominal, and subject to manufacturing tolerances. Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable 9-04 2 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Stranded - Unshielded Multi-Conductor Cable M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Stranded bare copper conductor 22, 18, 16, or 14 AWG • Semirigid PVC insulation • PVC Jacket • CMR / CL3R / FPLR • Sunlight resistant SPECIFICATIONS: NEC 725/800 UL-44 ETL CL-13 APPLICATION: Burglar alarm, audio control systems, limited circuits. Standard lengths of 1000 ft or 500 ft, in reels or boxes. RoHS Product Code Gauge Number of Conductors Insulation Thickness Jacket Thickness Overall Diameter Net Weight Lb/mft 656050 656052 656054 656056 656058 656059 22 22 22 22 22 22 2 4 6 8 10 12 0.006” 0.006” 0.006” 0.006” 0.006” 0.006” 0.0135” 0.0135” 0.0135” 0.0135” 0.0135” 0.0135” 0.107” 0.139” 0.155” 0.185” 0.242” 0.273” 8 15 20 26 32 37 656021 656023 656025 18 18 18 2 4 6 0.009” 0.009” 0.009” 0.0135” 0.0135” 0.0135” 0.148” 0.187” 0.213” 17 29 42 656018 656020 16 16 2 4 0.010” 0.010” 0.0175” 0.0175” 0.183” 0.233” 25 48 656016 656017 14 14 2 4 0.020” 0.020” 0.020” 0.020” 0.248” 0.318” 42 80 Conductor Gauge AWG Conductor Construction Wire/AWG Conductor Resistance D.C. Maximum Ù/kft @ 200C Temperature Rating 0 C 22 7/30 16.3 60 C 18 19/31 6.55 60 C Voltage Rating 0 300 V 0 300 V 0 16 26/30 4.00 60 C 300 V 14 41/301 2.60 600C 300 V Condumex Wire and Cable Non-Stocked item, subject to minimum quantity. *All values are nominal, and subject to manufacturing tolerances. th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 9-04 3 RoHS Stranded - Shielded Multi-Conductor Cable M.R. ECOLGICAL Telecom Cables DESCRIPTION:: • Stranded bare copper conductor 22,18,16 or 14 AWG • Semirigid PVC insulation • Aluminum Foil - Polyester Shield • Drain Wire • CMR / CL3R / FPLR • PVC Jacket • Sunlight resistant 4 SPECIFICATIONS: NEC 725/800, UL-444/13 ETL Listed RoHS Product Code Gauge Number of Conductors Insulation Thickness Jacket Thickness Overall Diameter Net Weight Lb/mft 656090 656091 656092 656094 22 22 22 22 2 3 4 6 22 8 0.0135” 0.0135” 0.0135” 0.0135” 0.0135” 0.135” 0.136” 0.162” 0.181” 0.208” 14 16 20 27 656096 0.006” 0.006” 0.006” 0.006” 0.006” 34 656070 656071 656072 656074 18 18 18 18 2 3 4 6 0.008” 0.008” 0.008” 0.008” 0.0135” 0.0135” 0.0135” 0.0135” 0.115” 0.173” 0.212” 0.245” 24 30 38 52 656065 656067 16 16 2 4 0.010” 0.010” 0.0175” 0.0175” 0.212” 0.262” 33 58 Conductor Gauge AWG Conductor Construction Wire/AWG Conductor Resistance D.C. Maximum 0 Ù/kft @ 20 C Temperature Rating 0 C Voltage Rating 22 7/30 16.30 600C 300 V 18 19/31 6.55 600C 300 V 16 26/30 4.00 600C 300 V Condumex Wire and Cable 9-04 APPLICATION: Burglar alarm, audio control systems, limited circuits. Standard lengths of 1000 ft or 500 ft, in reels or boxes. th Non-Stocked item, subject to minimum quantity. 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS High Strand - Unshielded Multi-Conductor Cable M.R. ECOLGICAL Telecom Cables DESCRIPTION: • High strand copper conductor 16, 14, or 12 AWG • Semirigid PVC insulation • Tissue paper wrap • Nylon rip cord • PVC Jacket • CL3R APPLICATION: Burglar alarm, audio control systems, limited circuits. Standard lengths of 1000 ft or 500 ft, in reels or boxes. SPECIFICATIONS: NEC 725/800 UL-444/13 ETL RoHS Product Code Gauge Number of Conductors Insulation Thickness Jacket Thickness Overall Diameter Net Weight Lb/mft 656018HS 656020HS 16 16 2 4 0.015” 0.015” 0.020” 0.020” 0.202” 0.254” 29 52 656016HS 656017HS 14 14 2 4 0.020” 0.020” 0.020” 0.020” 0.256” - 47 - TBA 12 2 - - - - Conductor Gauge AWG Conductor Construction Wire/AWG Conductor Resistance D.C. Maximum Ù/kft @ 200C Temperature Rating 0 C 16 65/34 4.02 60 C 14 65/32 2.60 600C 12 - - 60 C Condumex Wire and Cable 0 0 Voltage Rating 300 V Non-Stocked item, subject to minimum quantity. *All values are nominal, and subject to manufacturing tolerances. 300 V 300 V th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 5 RoHS Speaker/Zip Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Stranded copper conductors 22, 18, or 16 AWG • PVC insulation • CL2 APPLICATION: Burglar alarm, audio control systems, limited circuits. STANDARD LENGTH Standard lengths of 1000 ft, 500 ft, 250 ft reels or boxes. SPECIFICATIONS: NEC 725 UL13 RoHS Product Code Number of Conductors/ Gauge Jacket Thickness External Dimensions Inches Net Weight Lb/kft 720553 *720559 22 22 0.02” 0.02” 0.132 x 0.070” 0.132 x 0.070” 9 9 720583 18 0.022” 0.169 x 0.089” 17 720600 16 0.024” 0.201 x 0.110” 28 * Non UL-approved Conductor Construction Wire/AWG 7/30 Bare Copper 16.30 Tinned Copper 17.10 300 V 18 19/31 6.55 6.90 300 V 16 26/30 4.00 4.20 300 V Condumex Wire and Cable 8-04 6 Conductor Resistance D.C. Maximum Ù/kft @ 200C Conductor Gauge AWG 22 th Voltage Rating *All values are nominal, and subject to manufacturing tolerances. 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Thermostat / Control Cables M.R. ECOLGICAL Telecom Cables APPLICATION: Thermostat cable for, air condition control, heating control, intercom systems. DESCRIPTION: • Solid bare copper conductors 20 and 18 AWG • Semirigid PVC insulation • Sunlight resistant brown PVC Jacket • CL2R STANDARD LENGTH SPECIFICATIONS: NEC 725 UL-13 ETL Listed RoHS Standard lengths of 500 ft or 250 ft reels. Brown in stock, white available with minimum purchase requirement. Product Code Gauge Number of Conductors Insulation Thickness Jacket Thickness Overall Diameter Net Weight Lb/kft 666510 666511 666512 666513 666514 666516 18 18 18 18 18 18 2 3 4 5 6 8 0.0075” 0.0075” 0.0075” 0.0075” 0.0075” 0.0075” 0.013” 0.013” 0.013” 0.013” 0.013” 0.013” 0.126” 0.129” 0.161” 0.185” 0.185” 0.220” 14 20 27 33 40 52 666520 666521 666522 666523 666524 666525 666527 20 20 20 20 20 20 20 2 3 4 5 6 7 9 0.006” 0.006” 0.006” 0.006” 0.006” 0.006” 0.006” 0.013” 0.013” 0.013” 0.013” 0.013” 0.013” 0.013” 0.105” 0.106” 0.131” 0.150” 0.150” 0.210” 0.224” 10 13 18 22 26 31 38 Conductor Gauge AWG Conductor Resistance D.C. Maximum Ù/kft @ 200C Temperature Rating 0 C Voltage Rating 20 10.12 60 300 V 18 6.40 60 300 V Condumex Wire and Cable Non-Stocked item, subject to minimum quantity. *All values are nominal, and subject to manufacturing tolerances. th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 8-04 7 RoHS UNSHIELDED FIRE ALARM CABLE M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Solid bare copper conductor 22, 18, 16 or 14 AWG • Semirigid PVC insulation • Insulated conductors are cabled in all constructions • PVC jacket • Rip-Cord • FPLR SPECIFICATIONS NEC 760 UL-1424 ETL Listed RoHS *All values are nominal, and subject to manufacturing tolerances. Gauge Number of Conductors Insulation Thickness Jacket Thickness Overall Diameter Net Weight Lb/kft 666551 22 4 0.075” 0.020” 0.137” 15 666556 666558 666559 666560 18 18 18 18 2 4 6 8 0.010” 0.010” 0.010” 0.010” 0.020” 0.020” 0.020” 0.020” 0.146” 0.183” — 0.265” 17 31 51 58 666591 666593 16 16 2 4 0.010” 0.010” 0.020” 0.020” 0.165” 0.208” 24 44 666596 666597 14 14 2 4 0.013” 0.013” 0.020” 0.020” 0.205” 0.260” 36 68 Conductor Gauge AWG Conductor Resistance D.C. Maximum Ù/kft @ 200C Temperature Rating 0 C 0 0 300 V 0 300 V 16.30 -20 C to 60 C 6.40 -20 C to 60 C 16 4.00 -20 C to 60 C 2.52 Voltage Rating 0 22 18 Condumex Wire and Cable 8 Standard lengths of 1000 ft or 500 ft reels or boxes. Product Code 14 8-04 APPLICATION: Smoke detectors, burglar alarm, critical control circuits, power limited circuits. 0 0 300 V 0 0 300 V -20 C to 60 C th Non-Stocked item, subject to minimum quantity. 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS SHIELDED FIRE ALARM CABLE M.R. ECOLGICAL Telecom Cables DECRIPTION: • Solid bare copper conductor 18, 16, 14 or 12 AWG • Semirigid PVC insulation • Insulated conductors are cabled in all constructions • Polyester - aluminum foil shield • Drain wire, stranded 22 or 18 AWG • PVC Jacket • FPLR • Rip-Cord APPLICATION: Smoke detectors, burglar alarm, critical control circuits, power limited circuits. Standard lengths of 1000 ft or 500 ft reels or boxes. SPECIFICATIONS: NEC 760 UL-1424 ETL Listed RoHS Product Code Gauge Number of Conductors Insulation Thickness Jacket Thickness Overall Diameter Net Weight Lb/kft 666571 666573 18 18 2 4 0.010” 0.010” 0.020” 0.020” 0.170” 0.216” 25 39 666581 666582 16 16 2 4 0.010” 0.010” 0.020” 0.020” 0.205” 0.283” 36 56 666585 666586 14 14 2 4 0.013” 0.013” 0.020” 0.020” 0.241” 0.205” 51 82 666590 12 4 0.013” 0.020” 0.260” 66 Voltage Rating Conductor Gauge AWG Conductor Resistance D.C. Maximum 0 Ù/kft @ 20 C Temperature Rating 0 C 18 6.40 -200C to 60 C 300 V 16 4.00 0 -200C 60to C600C 300 V 14 2.56 -200C to 60 C 12 Condumex Wire and Cable 4.00 0 0 0 300 V 0 300 V -20 C to 60 C Non-Stocked item, subject to minimum quantity. th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 8-04 9 RoHS UNSHIELDED FIRE ALARM CABLE M.R. ECOLGICAL Telecom Cables PLENUM FIRE ALARM CABLE DESCRIPTION: APPLICATION: Typically used on smoke detectors, fire protective circuits, fire alarms and other signals used in the fire protection circuits. Solid bare copper conductors. Polyvinyl chloride (PVC) smokeguard compound insulation. Conductors cabled into a core. Flame retardant PVC somokeguard compound jacket. Flame test: Plenum as per NFPA 262. SPECIFICATIONS: UL-1424 UL-13 UL listed FPLP/CL3P Quality System ISO-9001 Product Gauge Number of Code Conductor Thickness Overall Diameter Net Weight 14 14 2 4 0.01142 0.01142 0.01575 0.01654 0.1929” 0.2480” 35.614 66.525 667162 667164 16 16 2 4 0.00949 0.00949 0.01378 0.01575 0.1575” 0.2047” 22.847 43.006 667182 667183 18 18 2 3 0.00949 0.00949 0.01378 0.01378 0.136” 0.138” 16.127 22.175 667184 18 4 0.00949 0.01378 0.173” 28.895 Conductor Gauge AWG Conductor Resistance D.C. Maximum 0 Ù/kft @ 20 C Temperature Rating 0 C Voltage Rating 14 2.53 75 C 0 300 V 4.02 0 300 V 0 300 V 18 Condumex Wire and Cable 10 Thickness Jacket 667142 667144 16 8-04 s Insulation 6.40 75 C 75 C Standard lengths of 1000 ft or 500 ft reels or boxes. 2590 114th Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS SHIELDED FIRE ALARM CABLE M.R. ECOLGICAL Telecom Cables PLENUM SHIELDED FIRE ALARM CABLE DESCRIPTION: APPLICATION: Typically used on smoke detectors, fire protective circuits, fire alarms and other signals used in the fire protection circuits. Solid bare copper conductors. Polyvinyl chloride (PVC) smokeguard compound insulation. Conductors cabled into a core. Flame retardant PVC somokeguard compound jacket. Flame test: Plenum as per NFPA 262. SPECIFICATIONS: UL-1424 UL-13 UL listed FPLP/CL3P Quality System ISO-9001 Product Gauge Number of Code Conductor s Insulation Thickness Jacket Thickness Overall Diameter Net Weight 667142 667144 14 14 2 4 0.01142 0.01142 0.01575 0.01654 0.1929” 0.2480” 35.614 66.525 667162 667164 16 16 2 4 0.00949 0.00949 0.01378 0.01575 0.1575” 0.2047” 22.847 43.006 Conductor Gauge AWG Conductor Resistance D.C. Maximum 0 Ù/kft @ 20 C Temperature Rating 0 C Voltage Rating 14 2.53 75 C 0 300 V 16 4.02 0 75 C 300 V 18 6.40 75 C 0 300 V Condumex Wire and Cable Standard lengths of 1000 ft or 500 ft reels or boxes. 2590 114th Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 8-04 11 RoHS Voice-Grade Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • 22 or 24 gauge solid bare copper conductor • PVC insulation • Insulated conductors twisted into pairs • PVC Jacket • CM or CMR • Operating Temp: -20 C to 75 C SPECIFICATIONS: NEC 800 UL-444 RoHS ANSI/EIA/TIA 568-B.2-1 Standard put-ups are 1000 foot boxes. FEATURES: Verified for Category 3 and ETL listed Product Code Gauge Number of Pairs 662448* 662451 662459 662462 662464 662467 662471 24 24 24 24 24 24 24 2 3 4 6 8 12 25 662480* 662481 662482 662484 22 22 22 22 2 3 4 6 Insulation Thickness Jacket Thickness Overall Diameter Net Weight Lb/kft 0.0085” 0.0135” 0.0135” 0.0135” 0.0135” 0.0135” 0.0135” 0.0135” 0.160” 0.176” 0.190” 0.238” 0.269” 0.306“ 0.397” 11 15 19 27 30 50 100 0.013” 0.013” 0.013” 0.013” 0.179” 0.197” 0.213” 0.267” 15 20 26 37 * Add SW to part number for special color code (Station Wire) Rd/Gr & Yl/Bk *All values are nominal, and subject to manufacturing tolerances. Conductor Resistance d.c. Maximum 0 @ 20 C Nominal Impedance Ù Nominal Capacitance 1 to 16 MHz pf/ft 28.6 Ù/kft 100 + 15 20 Transmission Characteristics Frequency MHz Maximum Attenuation dB/100 m Minimum NEXT loss dB/100 m 1 4 10 16 2.6 5.6 9.7 13.1 41 32 26 23 Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable 9-04 12 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Data-Grade Cables - Cat 5E PVC CM or CMR Rated 350Mhz M.R. ECOLGICAL Telecom Cables DESCRIPTION: • 24 gauge solid bare copper conductor • Polyethylene insulation • Insulated conductors twisted into pairs • PVC Jacket • CMR or CM • Operating Temp: -20 C to 75 C FEATURES: Category 5E and ETL listed, intended for riser installation. Standard put-ups are 1000 boxes SPECIFICATIONS: NEC 800 RoHS ANSI/EIA/TIA 568-B.2-1 Product Code + 664455 ~ 664455CM + 664463 Number of Pairs 4 4 6 + CMR Rated Cable Overall Diameter 0.189” 0.189” 0.228” Net Weight Lb/mft 18 18 25 Jacket Insulation Thickness Thickness 0.017” 0.0073” 0.017” 0.0073” 0.017” 0.0073” ~ CM Rated Cable Conductor Resistance d.c. 0 Maximum @ 20 C Mutual Capacitance 28.6 Ù/ft Delay Skew Maximum pf/ft Characteristic Impedance Ù 1 to 100 MHz 14 100 + 15 45 Condumex Wire and Cable ns Return Loss Minimal (fin Mhz) dB 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-7.0Log(f/20) ; 20<f<100 Frequency MHz Transmission Characteristics Maximum Minimum Minimum Attenuation NEXT Loss FEXT Loss dB/100 m dB/100 m dB/100 m 4 10 16 31 100 4.1 6.5 8.2 11.7 22.0 56.3 50.3 47.2 42.9 35.3 51.8 43.8 39.7 33.9 23.8 200 250 350 32.4 36.9 44.9 30.8 29.3 27.1 17.8 15.8 12.9 *Typical values, there are no specified values at this frequency in the specification th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 13 RoHS Data-Grade Cables - Cat 5E Plenum Rated 350Mhz M.R. ECOLGICAL Telecom Cables DESCRIPTION: • 24 gauge solid bare copper conductor • FEP insulation • Insulated conductors twisted into pairs • Low smoke PVC Jacket • CMP FEATURES: Category 5E verified and ETL listed, intended for horizontal, riser and plenum installation. Standard put-ups are 1000 boxes SPECIFICATIONS: NEC 800 RoHS ANSI/EIA/TIA 568-B.2-1 Product Code 664373 Number of Pairs 4 Conductor Resistance d.c. 0 Maximum @ 20 C Mutual Capacitance 28.6 Ù/ft Overall Diameter 0.195” Net Weight Jacket Insulation Lb/mft Thickness Thickness 21 0.013” 0.0065” Delay Skew Maximum pf/ft Characteristic Impedance Ù 1 to 100 MHz 14 100 + 15 45 ns Frequency MHz Transmission Characteristics Maximum Minimum Minimum Attenuation NEXT Loss FEXT Loss dB/100 m dB/100 m dB/100 m Return Loss Minimal (fin Mhz) dB 4 10 16 31 100 4.1 6.5 8.2 11.7 22.0 56.3 50.3 47.2 42.9 35.3 51.8 43.8 39.7 33.9 23.8 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-7.0Log(f/20) ; 20<f<100 200 250 350 32.4 36.9 44.9 30.8 29.3 27.1 17.8 15.8 12.9 *Typical values, there are no specified values at this frequency in the specification *All values are nominal, and subject to manufacturing tolerances. Condumex Wire and Cable 2-05 14 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Data-Grade Cables - Cat 5E CMR Rated 350Mhz M.R. ECOLGICAL Telecom Cables INSIDE CABLE CATEGORY 5E - STRANDED *All values are nominal, and subject to manufacturing tolerances. DESCRIPTION: • 24 gauge stranded bare copper conductor • Polyethylene insulation • Insulated conductors twisted into pairs • PVC Jacket • CM or CMR FEATURES: Category 5E verified and ETL listed Standard put-ups are 1000 foot reels, boxes and reel-in-a-box. SPECIFICATIONS: NEC 800,CM rated ANSI/EIA/TIA 568-B.2-1 RoHS Product Code Number of Pairs Conductor Construction Wires/AWG Overall Diameter 664555 4 7/32 0.217” Conductor Resistance d.c. 0 Maximum @ 20 C Mutual Capacitance 28.6 Ù/ft Net Weight Jacket Insulation Lb/mft Thickness Thickness 24 Delay Skew Maximum pf/ft Characteristic Impedance Ù 1 to 100 MHz 14 100 + 15 45 ns Transmission Characteristics Frequency MHz Maximum Attenuation dB/100 m Minimum NEXT Loss dB/100 m Return Loss Minimal (fin Mhz) dB 4 10 16 31 100 4.9 7.8 9.9 14.1 26.4 56.3 50.3 47.2 42.9 35.3 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-8.6Log(f/20) ; 20<f<100 200* 250* 350* 38.9 44.2 53.8 30.8 29.3 27.1 0.020” 0.0071” *Typical values, there are no specified values at this frequency in the specification Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 15 RoHS Shielded Data-Grade Cables - Cat 5E CMR Rated 350Mhz M.R. ECOLGICAL Telecom Cables INSIDE CABLE CATEGORY 5E - SHIELDED DESCRIPTION: • 24 gauge solid bare copper conductor • Polyethylene insulation • Insulated conductors twisted into pairs • Tinned copper drain wire • Foil Shield • -10 C to 60 C • PVC Jacket • CM or CMR Product Code 664405 Number of Pairs 4 Overall Diameter 0.276” Net Weight Lb/mft 30 Delay Skew Maximum pf/ft Characteristic Impedance Ù 1 to 100 MHz 14 100 + 15 45 Conductor Resistance d.c. 0 Maximum @ 20 C Mutual Capacitance 28.6 Ù/ft ns Jacket Insulation Thickness Thickness 0.024” 0.010” Return Loss Minimal (fin Mhz) dB 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-7.0Log(f/20) ; 20<f<100 FEATURES: Category 5E and ETL listed SPECIFICATIONS: CMR Rated, ISO/IEC 11801 ANSI/EIA/TIA 568-B.2-1 RoHS Standard put-ups are 1000 foot reels. Frequency MHz Transmission Characteristics Maximum Minimum Minimum Attenuation NEXT Loss FEXT Loss dB/100 m dB/100 m dB/100 m 4 10 16 31 100 4.1 6.5 8.2 11.7 22.0 56.3 50.3 47.2 42.9 35.3 51.8 43.8 39.7 33.9 23.8 200 250 350 32.4 36.9 44.9 30.8 29.3 27.1 17.8 15.8 12.9 *Typical values, there are no specified values at this frequency in the specification Condumex Wire and Cable 2-05 16 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Data-Grade Cables - Cat 5E+ CMR Rated 400Mhz M.R. ECOLGICAL Telecom Cables DESCRIPTION: • 24 gauge solid bare copper conductor • Polyethylene insulation • Insulated conductors twisted into pairs • PVC Jacket • CM orCMR FEATURES: Category 5E and ETL listed, intended for horizontal installation. Standard put-ups are 1000 foot boxes SPECIFICATIONS: NEC 800 RoHS ANSI/EIA/TIA 568-B.2-1 Product Code 664455A Number of Pairs 4 Overall Diameter 0.190” Net Weight Jacket Insulation Lb/mft Thickness Thickness 18 0.017” 0.0073” Delay Skew Maximum pf/ft Characteristic Impedance Ù 1 to 100 MHz 14 100 + 15 45 Conductor Resistance d.c. 0 Maximum @ 20 C Mutual Capacitance 28.6 Ù/ft ns Frequency MHz Return Loss Minimal (fin Mhz) dB 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-7.0Log(f/20) ; 20<f<100 Transmission Characteristics Maximum Minimum Minimum Attenuation NEXT Loss FEXT Loss dB/100 m dB/100 m dB/100 m 1 10 16 31 100 2.1 6.5 8.2 11.7 22.0 65.3 50.3 47.2 42.9 35.3 63.8 43.8 39.7 33.9 23.8 200* 250* 350* 400* 32.4 36.9 44.9 48.5 30.8 29.3 27.1 26.3 17.8 15.8 12.9 11.8 *Typical values, there are no specified values at this frequency in the specification Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 17 RoHS Data-Grade Cables - Cat 5E+ M.R. ECOLGICAL Telecom Cables DESCRIPTION: • 24 gauge solid bare copper conductor • Polyethylene insulation • Insulated conductors twisted into pairs • Core filled with water blocking gel • Polyethylene Jacket FEATURES: Category 5E intended for structured cabling in telecommunications networks, for outdoor use in direct burial or duct installations. Standard put-ups are 1000 foot boxes SPECIFICATIONS: ISO/IEC 11801 RoHS ANSI/EIA/TIA 568-B.2-1 Product Code 664455DB Conductor Resistance d.c. 0 Maximum @ 20 C Number of Pairs 4 Mutual Capacitance pf/ft 28.6 Ù/ft 16 Overall Diameter 0.225” Characteristic Impedance Ù 1 to 100 MHz 100 + 15 (1-100MHz) 100 ± 22 (100-200MHz) Net Weight Jacket Lb/mft Thickness 18 0.0205” Delay Skew Maximum ns 45 Frequency MHz Return Loss Minimal (fin Mhz) dB 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-7.0Log(f/20) ; 20<f<100 *All values are nominal, and subject to manufacturing tolerances. Condumex Wire and Cable 2-05 18 Transmission Characteristics Maximum Minimum Minimum Attenuation NEXT Loss FEXT Loss dB/100 m dB/100 m dB/100 m 1 10 16 31 100 2.1 6.5 8.2 11.7 22.0 65.3 50.3 47.2 42.9 35.3 63.8 43.8 39.7 33.9 23.8 200* 250* 350* 400* 32.4 36.9 44.9 48.5 30.8 29.3 27.1 26.3 17.8 15.8 12.9 11.8 *Typical values, there are no specified values at this frequency in the specification th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Data-Grade Cables - Cat 6 CMR Rated 250Mhz M.R. ECOLGICAL Telecom Cables DESCRIPTION: • 23 gauge solid bare copper conductor • Polyethylene insulation • Insulated conductors twisted into pairs • PVC Jacket • Polyethylene crossweb to separate the pairs • CM or CMR FEATURES: Category 6 verified and UL and ETL listed, intended for horizontal installation. Standard put-ups are 1000 reel-in-a-box. SPECIFICATIONS: NEC 800 UL-444 RoHS ANSI/EIA/TIA 568-B.2-1 Product Code 664466 Conductor Resistance d.c. 0 Maximum @ 20 C 26 Ù/ft Number of Pairs 4 Mutual Capacitance Overall Diameter 0.244” Characteristic Impedance Delay Skew Maximum Ù ns pf/ft 16.8 Net Weight Jacket Insulation Lb/mft Thickness Thickness 26 0.017” 0.009” 100 + 15 (1 - 100 MHz) 100 + 22 (100 - 200 MHz) 100 + 32 (200 to 250 MHz) Condumex Wire and Cable 45 Return Loss Minimal (fin MHz) dB 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-7.0Log(f/20) ; 20<f<250 Frequency MHz Transmission Characteristics Maximum Minimum Attenuation NEXT Loss dB/100 m dB/100 m Minimum FEXT Loss dB/100 m 10 16 31 100 200 250 6.0 7.7 10.7 19.8 29.0 32.8 59.3 36.2 51.9 44.3 39.8 38.3 47.8 43.2 37.9 27.8 21.8 19.8 350* 39.8 36.1 16.9 *Typical values, there are no specified values at this frequency in the specification th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 1-06 19 RoHS Data-Grade Cables - Cat 6 CMP Rated 250Mhz M.R. ECOLGICAL Telecom Cables *All values are nominal, and subject to manufacturing tolerances. DESCRIPTION: • 23 gauge solid bare copper conductor • FEP insulation • Insulated conductors twisted into pairs • Plenum rated PVC Jacket • Polyethylene crossweb to separate the pairs • CMP SPECIFICATIONS: ISO/IEC 11801 (2002) ANSI/EIA/TIA 568-B.2-1 RoHS Product Code 664866 Number of Pairs 4 Overall Diameter 0.232” Mutual Capacitance Characteristic Impedance Delay Skew Maximum pf/ft Ù ns 26 Ù/ft 16.8 100 + 15 (1 - 100 MHz) 100 + 22 (100 - 200 MHz) 100 + 32 (200 to 250 MHz) Condumex Wire and Cable 1-06 20 45 Standard put-ups are 1000 reel-in-a-box. UL-444: MPP NEMA WC 66 Net Weight Jacket Lb/mft Thickness 28 0.014” Conductor Resistance d.c. 0 Maximum @ 20 C FEATURES: Category 6 verified and UL and ETL listed, intended for horizontal installation. Return Loss Minimal (fin MHz) dB 20+5Log(f) ; 1<f<10 25 ; 10<f<20 25-7.0Log(f/20) ; 20<f<250 Frequency MHz Transmission Characteristics Maximum Minimum Attenuation NEXT Loss dB/100 m dB/100 m Minimum FEXT Loss dB/100 m 10 16 31 100 200 250 6.0 7.7 10.7 19.8 29.0 32.8 59.3 36.2 51.9 44.3 39.8 38.3 47.8 43.2 37.9 27.8 21.8 19.8 350* 39.8 36.1 16.9 *Typical values, there are no specified values at this frequency in the specification th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of solid copper wire • Gas injected foamed polyethylene insulation • Braid of copper wires • Black PVC jacket PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: CM or CL2 ETL Listed NEC 725/800 RoHS Standard lengths of 1000 ft boxes Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft 801426 811428 20 AWG 20 AWG 0.144” 0.144” 0.242” 0.242” 95% 95% 31 31 Impedance Ù *All values are nominal, and subject to manufacturing tolerances. 75 + 5 Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 10.34 81 16 Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 1.22 2.06 3.94 4.72 5.83 6.47 7.62 8.24 8.87 COAXIAL CABLE RG 6/U BC - 95% BC BRAID DESCRIPTION: • Conductor of solid copper wire • Gas injected foamed polyethylene insulation • Braid of copper wires • Black PVC jacket Standard stock lengths of 1000 ft boxes PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: CM or CL2 ETL Listed NEC 725/800 RoHS Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft 809145 18 AWG 0.180” 0.268” 95% 42 Impedance Ù 75 + 5 Condumex Wire and Cable Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 6.37 81 16 Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 0.81 1.60 3.08 3.70 4.56 5.09 6.00 6.50 7.00 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 21 RoHS RG-59U - Plenum Coaxial Cables M.R. ECOLGICAL Telecom Cables COAXIAL CABLE RG 59/U BC - 95% BC BRAID - PLENUM RATED DESCRIPTION: • Conductor of solid copper wire • Foamed fluorinated ethylene propylene insulation • Braid of copper wires • Low Smoke White PVC jacket PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: NEC Type CMP RoHS Standard lengths of 1000 ft reels Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft 801426FEP 20 AWG 0.135” 0.193” 95% 35 Impedance Ù *All values are nominal, and subject to manufacturing tolerances. 75 Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 10.0 75 16.1 * Minimum order quantity required. Condumex Wire and Cable 5-05 22 th Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 0.89 1.95 3.59 4.27 5.30 5.90 6.96 7.54 8.09 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS RG-6U - Plenum Coaxial Cables M.R. ECOLGICAL Telecom Cables COAXIAL CABLE RG 6/U BC - 95% BC BRAID - PLENUM RATED DESCRIPTION: • Conductor of solid copper wire • Foamed fluorinated ethylene propylene insulation • Braid of copper wires • Low Smoke White PVC jacket PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: NEC Type CMP RoHS Standard lengths of 1000 ft reels Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft 809146FEP 18 AWG 0.170” 0.233” 95% 42 Impedance Ù 75 Conductor Resistance 0 @ 20 C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 6.4 83 16.3 * Minimum order quantity required. Condumex Wire and Cable Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 0.67 1.60 2.87 3.43 4.26 4.71 5.59 6.00 6.54 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 5-05 23 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of copper clad steel • Gas injected polyolefin insulation • Polyester - aluminum foil, adhered to the insulation • Braid of aluminum wires • PVC jacket PROPERTIES: High speed of propagation. SPECIFICATIONS: UL-444 RoHS SCTE IPS SP 001 NEC 800/825 CM or CATV ETL Listed Standard lengths of 1000 ft reels. Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft 807520 14 AWG 0.28” 0.397” 60% 61 Impedance Ù *All values are nominal, and subject to manufacturing tolerances. 75 Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 12.9 82 16 Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable 5-05 24 th Attenuation dB/100 ft Frequency MHz Maximum 250 500 750 1000 1200 1540 1800 2200 2.20 3.19 3.99 4.67 4.93 5.69 6.24 7.03 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of copper clad steel • Gas injected foamed polyethylene • Polyester - aluminum foil, adhered to the insulation • Braid of aluminum wires • Water-block flooding compound • Black linear low density polyethylene PROPERTIES: High speed of propagation. SPECIFICATIONS: UL-444 RoHS SCTE IPS SP 001 NEC 800/825 CM or CATV ETL Listed Standard lengths of 1000 ft or 500 ft reels. Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft TBD 14 AWG 0.28” 0.397” 60% 52 Impedance Ù 75 Conductor Resistance 0 @ 20 C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 12.9 82 16 Attenuation dB/100 ft Frequency MHz Maximum 250 500 750 1000 1200 1540 1800 2200 2.20 3.19 3.99 4.67 4.93 5.69 6.24 7.03 Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 5-05 25 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of bare copper • Solid polyethylene insulation • Braid of tinned copper wires • PVC jacket PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: UL-13 RoHS CL2 ETL Listed Standard lengths of 1000 ft reels Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft 809940 20 AWG 0.116” 0.195” 95% 26 Non-Stocked item, subject to minimum quantity. *All values are nominal, and subject to manufacturing tolerances. Condumex Wire and Cable 2-05 26 Impedance Ù Conductor Resistance @ 200C Ù/kft Propagation Speed 5 Nominal Capacitance pF/ft 50 + 5 10.34 66 30 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of stranded, tinned copper • Solid polyethylene insulation • Braid of tinned copper wires • PVC jacket PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: UL-13 RoHS CL2 ETL Listed Standard lengths of 1000 ft or 500 ft reels or boxes. Product Code Conductor Diameter Conductor Construction Wires/AWG Insulation Diameter Overall Diameter Braid Coverage Net Weight Lb/kft 800116 20 AWG 19 x 33 AWG 0.116” 0.195” 95% 26 Impedance Ù Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 12.35 29 66 50 + 5 Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable Attenuation dB/100 ft Frequency MHz 100 400 1000 1800 2000 Maximum 4.28 9.32 16.58 25.07 27.16 *All values are nominal, and subject to manufacturing tolerances. th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 27 RoHS Rg6U PVC Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of copper clad steel • Gas injected foamed polyethylene insulation • Polyester - aluminum foil, adhered to the insulation • Braid of aluminum wires • PVC jacket PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: UL-444, NEC 800/820 SCTE-IPS-SP-001 RoHS CM or CATV ETL listed Standard lengths of 1000 ft boxes Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 809114 18 AWG 0.180” 0.264” 40% Impedance Ù Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 32 81 16 75 + 5 Non-Stocked item, subject to minimum quantity. Condumex Wire and Cable 2-05 28 Net Weight Lb/kft 26 Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 0.81 1.60 3.08 3.70 4.58 5.09 6.00 6.50 7.00 *All values are nominal, and subject to manufacturing tolerances. th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Rg6U PVC Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of copper clad steel • Gas injected foamed polyethylene insulation • Polyester - aluminum foil, adhered to the insulation • Braid of aluminum wires • PVC jacket • Operating Temp: -20 C to 60 C PROPERTIES: Flexible high speed of propagation. SPECIFICATIONS: UL-444, NEC 800/820 SCTE-IPS-SP-001 RoHS CM or CATV ETL listed Standard lengths of 1000 ft reels or boxes 500 ft boxes Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 809116R 18 AWG 0.139” 0.226” 60% Impedance Ù Conductor Resistance 0 @ 20 C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 39.04 82 16.18 75 + 3 Condumex Wire and Cable Net Weight Lb/kft 29.42 Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 870 1250 2200 3000 0.81 1.60 3.08 3.70 4.58 6.50 7.62 9.49 11.54 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 29 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of copper clad steel • Gas injected foamed polyethylene insulation • Polyester - aluminum foil, adhered to the insulation • Inner braid of aluminum wires • Overlapped aluminum - polyester - aluminum foil, • Outer braid of aluminum wires • PVC jacket *All values are nominal, and subject to manufacturing tolerances. 30 SPECIFICATIONS: UL-444, NEC 800/820 SCTE-IPS-SP-001 RoHS CM or CATV ETL Listed Standard lengths of 1000 ft or 500 ft reels or 500 ft boxes. Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 801189 18 AWG 0.180” 0.291” 1st Layer: 60% 2nd Layer: 40% Impedance Ù Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 32 81 16 75 + 5 Condumex Wire and Cable 2-05 PROPERTIES: Flexible, high speed of propagation. th Net Weight Lb/kft 30 Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 0.81 1.60 3.08 3.70 4.58 5.09 6.00 6.50 7.00 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of bare copper • Gas injected foamed polyethylene insulation • Polyester - aluminum foil, adhered to the insulation • Inner braid of alumium wires • Overlaped aluminum - polyester - aluminum foil, • Outer braid of alumium wires • PVC jacket *All values are nominal, and subject to manufacturing tolerances. PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: UL-444, NEC 800/820 SCTE-IPS-SP-001 RoHS CM or CATV ETL Listed Standard lengths of 1000 ft or 500 ft reels or 500 ft boxes. Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 801189DSS 18 AWG 0.180” 0.291” 1st Layer: 60% 2nd Layer: 40% Impedance Ù Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 6.4 81 16 75 + 5 Condumex Wire and Cable Net Weight Lb/kft 33 Attenuation dB/100 ft Frequency MHz Maximum 1 10 50 100 200 400 700 900 1000 1200 1450 1800 2200 0.25 0.70 1.46 1.95 2.73 3.80 5.20 5.90 6.30 6.80 7.60 8.20 9.80 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 9-04 31 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables COAXIAL CABLE RG 6/U - 60% BRAID - PLENUM RATED DESCRIPTION: • Conductor of copper clad steel • Foamed fluorinated ethylene propylene insulation • Polyester - aluminum foil, adhered to the insulation • Braid of aluminum wires • Low smoke PVC jacket PROPERTIES: Flexible high speed of propagation. SPECIFICATIONS: NEC Type CMP RoHS Standard lengths of 1000 ft or 500 ft reels or boxes. Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 809116FEP 18 AWG 0.170” 0.235” 60% Impedance Ù 75 Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 28 83 16.3 *All values are nominal, and subject to manufacturing tolerances. * Minimum order quantity required. Net Weight Lb/kft 24 Attenuation dB/100 ft Frequency MHz 5 55 211 300 450 550 750 870 1000 Maximum 0.67 1.60 2.87 3.43 4.26 4.71 5.59 6.00 6.54 COAXIAL CABLE RG 6/U - QUAD SHIELD - PLENUM RATED DESCRIPTION: • Conductor of copper clad steel • Foamed fluorinated ethylene propylene insulation • Polyester - aluminum foil, adhered to the insulation • Inner braid of aluminum wires • Overlapped aluminum - polyester - aluminum foil, • Outer braid of aluminum wires • Low smoke PVC jacket Standard lengths of 1000 ft or 500 ft reels or 500 ft boxes. Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 801289FEP 18 AWG 0.170” 0.248” 1st Layer: 60% 2nd Layer: 40% Impedance Ù Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 28 83 16.3 * Minimum order quantity required. Condumex Wire and Cable 32 SPECIFICATIONS: NEC Type CMP RoHS Product Code 75 5-05 PROPERTIES: Flexible, high speed of propagation. th Net Weight Lb/kft 34 Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 0.67 1.60 2.87 3.43 4.26 4.71 5.59 6.00 6.54 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Coaxial Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: • Conductor of copper clad steel • Gas injected foamed polyethylene insulation • Polyester - aluminum foil, adhered to the insulation • Braid of aluminum wires • PVC jacket PROPERTIES: Flexible high speed of propagation. SPECIFICATIONS: UL-444, NEC 800/820 SCTE-IPS-SP-001 RoHS CM or CATV ETL listed Standard lengths of 1000 ft or 500 ft reels. Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 809220 18 AWG 0.180” (2 x) 0.264” 60% Impedance Ù Conductor Resistance 0 @ 20 C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 32 81 16 75 + 5 *All values are nominal, and subject to manufacturing tolerances. DESCRIPTION: • Conductor of copper clad steel • Gas injected foamed polyethylene insulation • Polyester - aluminum foil, adhered to the insulation • Inner braid of aluminum wires • Overlapped aluminum - polyester - aluminum foil, • Outer braid of aluminum wires • PVC jacket Attenuation dB/100 ft Frequency MHz Maximum 5 55 211 300 450 550 750 870 1000 0.81 1.60 3.08 3.70 4.58 5.09 6.00 6.50 7.00 PROPERTIES: Flexible, high speed of propagation. SPECIFICATIONS: UL-444, NEC 800/820 SCTE-IPS-SP-001 RoHS CM or CATV ETL listed Standard lengths of 1000 ft or 500 ft reels. Product Code Conductor Diameter Insulation Diameter Overall Diameter Braid Coverage 809221 18 AWG 0.180” (2 x) 0.291” 1st Layer: 60% 2nd Layer: 40% Impedance Ù 75 + 5 Condumex Wire and Cable Conductor Resistance @ 200C Ù/kft Propagation Speed Nominal Capacitance % pF/ft 6.4 83 16 Net Weight Lb/kft 50 Net Weight Lb/kft 70 Attenuation dB/100 ft Frequency MHz Maximum 1 10 50 100 200 400 700 900 1000 1200 1450 1800 2200 0.25 0.70 1.46 1.95 2.73 3.80 5.20 5.90 6.30 6.80 7.60 8.20 9.80 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 2-05 33 RoHS Home Control Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: One RG 59/U BC - 95% BC braid cable and one stranded 18 AWG 2 conductor cable PROPERTIES: 1One RG 59/U cable: • 20 AWG bare copper center conductor • Gas-injected foamed polyethylene insulation • 95% bare copper braid • PVC jacket 18 AWG Cable Properties Number of Insulation Jacket Conductors Thickness Thickness 2 0.009” 0.0135” RG 59/U Cable Properties Insulation Conductor Diameter Diameter AWG 20 Product Code Overall Diameter 820148 0.487 x 0.308” 1One, 18 AWG, 2 Conductor cable: • Stranded bare copper conductors • Semirigid PVC insulation • PVC jacket 1Overall PVC jacket Net Weight Lb/kft 74 SPECIFICATIONS: NEC 800 RoHS Overall Diameter Conductor Gauge AWG Conductor Construction Wires/AWG Conductor Resistance D.C. Maximum 0 Ù/kft @ 20 C Temperature Rating 0 60 C Voltage Rating 0.148 18 19/31 6.55 60 300 V Overall Diameter Braid Coverage Impedance Ù Conductor Resistance 0 @ 20 C Ù/kft Propagation Speed % Nominal Capacitance pF/ft 0.232” 95% 75 + 5 10.34 81 16 0.144” *All values are nominal, and subject to manufacturing tolerances. DESCRIPTION: One RG 59/U BC - 95% BC braid cable and two stranded 18 AWG wires DESCRIPTION: 1One RG 59/U cable: • 20 AWG bare copper center conductor • Gas-injected foamed polyethylene insulation • 95% bare copper braid • PVC jacket 18 AWG Wire Properties Insulation Overall Thickness Diameter 0.009” 0.063 RG 59/U Cable Properties Insulation Conductor Diameter Diameter AWG 20 0.144” Condumex Wire and Cable 2-05 34 Product Code Overall Diameter 820149X 0.336 x 0.455” 1Two,18 AWG wires: • Stranded bare copper conductors • Semirigid PVC insulation 1Overall PVC jacket SPECIFICATIONS: NEC 800 RoHS Net Weight Lb/kft 71 Conductor Gauge AWG Conductor Construction Wires/AWG Conductor Resistance D.C. Maximum 0 Ù/kft @ 20 C Temperature Rating 600C Voltage Rating 18 19/31 6.55 600C 300 V Overall Diameter Braid Coverage Impedance Ù Conductor Resistance 0 @ 20 C Ù/kft Propagation Speed % Nominal Capacitance pF/ft 0.232” 95% 75 + 5 10.34 81 16 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Home Control Cables M.R. ECOLGICAL Telecom Cables COMPOSITE CABLE - RG 6/U + 18/2 DESCRIPTION: One RG 6/U BC - 95% BC braid cable and one stranded 18 AWG 2 conductor cable PROPERTIES: 1One RG 6/U cable: • 18 AWG bare copper center conductor • Gas-injected foamed polyethylene insulation • 95% bare copper braid • PVC jacket Product Code Overall Diameter 2 0.0155” RG 6/U Cable Properties Conductor Conductor Diameter Diameter AWG 18 0.040” • Stranded bare copper conductors • Polypropylene insulation • PVC jacket Net Weight Lb/kft 59 820081SIM 0.264 x 0.485” 18 AWG Cable Properties Number of Insulation Conductors Thickness 1One, 18 AWG, 2 Conductor cable: 1Siamese construction SPECIFICATIONS: NEC 800 RoHS UL PVC 75OC *All values are nominal, and subject to manufacturing tolerances. Conductor Diameter Conductor Gauge AWG Conductor Construction Wires/AWG Temperature Rating 0 C Voltage Rating 0.046” 18 16/30 75 300 V Insulation Thickness Overall Diameter Insulation Braid Coverage Impedance Ù Nominal Capacitance pF/ft 0.070” 0.178 + .006” 95% 75 + 3 16.3 COMPOSITE CABLE - RG 59+ 18/2 DESCRIPTION: One RG 59BC - 95% BC braid cable and one stranded 18 AWG 2 conductor cable PROPERTIES: 1One RG 6/U cable: • 20 AWG bare copper center conductor • Gas-injected foamed polyethylene insulation • 95% bare copper braid • PVC jacket Product Code Overall Diameter 2 0.0091” RG 6/U Cable Properties Conductor Conductor Diameter Diameter AWG 20 0.032” Condumex Wire and Cable • Stranded bare copper conductors • Polypropylene insulation • PVC jacket Net Weight Lb/kft 59 820150SIM 0.264 x 0.485” 18 AWG Cable Properties Number of Insulation Conductors Thickness 1One, 18 AWG, 2 Conductor cable: 1Siamese construction SPECIFICATIONS: UL-1655 RoHS UL -13 *All values are nominal, and subject to manufacturing tolerances. Conductor Diameter Conductor Gauge AWG Conductor Construction Wires/AWG Temperature Rating 0 C Voltage Rating 0.043” 18 16/18 75 300 V Insulation Thickness Overall Diameter Insulation Braid Coverage Impedance Ù Nominal Capacitance pF/ft 0.056” 0.144 + .006” 95% 75 + 3 16.3 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 4-05 35 RoHS Home Control Cables M.R. ECOLGICAL Telecom Cables DESCRIPTION: 1Two RG 6/U Quad cables: • 18 AWG copper clad steel center conductor • Gas-injected foamed polyethylene insulation 1Two, 4-pair, Cat 5e cables • Solid copper conductors • Polyethylene insulation APPLICATION: Residential Cabling with structured design for voice, data, video and any other high-speed application. PROPERTIES: 19 mm Overall Diameter: 250 lbs Cable Weight per 1,000 feet: RoHS Standard lengths of 500 foot reels 1Overall PVC jacket Product Conductor Conductor Code Diameter Resistance TBD 18 AWG Insulation Diameter Braid Coverage Impedance 4.5 mm 60% - 40% 75 + 3Ù 105 Ù/km Conductor Diameter Number of Paris Conductor Resistance Impedance 24 AWG 4 90.5 Ù/km 100 + 15 Capacitance 52 pF/m Mutual Capacitance 45.9 pF/m *All values are nominal, and subject to manufacturing tolerances. Propagation Speed 81% Attenuation MHz 55 211 300 550 750 1000 dB/100 m 5.3 10.0 11.7 16.1 18.6 21.5 Properties at 100 m Frequency Attenuation PSNext MHz dB/100 m dB/100 4 10 16 62.5 100 4.1 6.5 8.2 17.0 22.0 53.3 42.3 44.2 35.4 32.3 DESCRIPTION: APPLICATION: 1Two RG 6/U Quad cables: Residential Cabling with structured design for voice, • 18 AWG copper clad steel center conductor data, video and any other high-speed application. • Gas-injected foamed polyethylene insulation. PROPERTIES: 1Two, 4-pair, Cat 5e cables 1Two, 62.5µ Multimode Fibers 19 mm Overall Diameter: • Solid copper conductors • Overall PVC jacket 255 lbs Cable Weight per 1,000 feet: • Tight-buffered • Polyethylene insulation Standard lengths of 500 foot reels distribution construction 1Overall PVC jacket RoHS Product Conductor Conductor Code Diameter Resistance TBD 18 AWG 36 Braid Coverage Impedance 4.5 mm 60% - 40% 75 + 3Ù 105 Ù/km Conductor Diameter Number of Paris Conductor Resistance Impedance 24 AWG 4 90.5 Ù/km 100 + 15 Capacitance 52 pF/m Mutual Capacitance 45.9 pF/m Number of Fibers Core Diameter Cladding Diameter Minimum Bend Radius 2 62.5 + 3 µm 125 + 2 µm 60 mm Condumex Wire and Cable 4-05 Insulation Diameter th Propagation Speed 81% Attenuation MHz 55 211 300 550 750 1000 dB/100 m 5.3 10.0 11.7 16.1 18.6 21.5 Properties at 100 m Frequency Attenuation PSNext MHz dB/100 m dB/100 4 10 16 62.5 100 4.1 6.5 8.2 17.0 22.0 53.3 47.3 44.2 35.4 32.3 Attenuation 3.2 dB/km @ 850 nm 0.9 dB/km @ 1300 nm 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 RoHS Home Control Cables M.R. ECOLGICAL Telecom Cables COMPOSITE CABLE - RG 6/U CABLE + CAT 5E SIAMESE DESCRIPTION: 1One RG 6/U Quad cable: • 18 AWG bare copper center conductor • Gas-injected foamed polyethylene insulation 1One, 4-pair, Cat 5E cable • Solid copper conductors • Polyethylene insulation 1Siamese construction APPLICATION: Residential Cabling with structured design for voice, data, video and any other high-speed application. PROPERTIES: 0.525 x 0.3” Overall Diameter: Cable Weight per 1,000 feet: 55 lbs. RoHS Standard lengths of 500 foot reels Braid Propagation Resistance r Product Speed Diameter Insulation Coverage Capacitance Code Conducto Conductor Diameter Impedance 821005 *All values are nominal, and subject to manufacturing tolerances. 18 AWG 4.5 mm 38 Ù/km 60% - 40% 75 + 3Ù Conductor Diameter Number of Pairs Conductor Resistance Impedance 24 AWG 4 93.8 Ù/km 100 + 15Ù Attenuation 52.0 pF/m Pair-to-Pair Capacitance Unbalance < 330 pF/100 m 81% MHz dB/100 m 55 211 300 550 750 1000 5.3 10.0 11.7 16.1 18.6 21.5 Properties at 100 m Frequency Attenuation PSNext MHz dB/100 m dB/100ft 4.1 4 53.3 10 6.5 47.3 16 8.2 44.3 62.5 17.0 35.4 100 22.0 32.3 COMPOSITE CABLE - 2 X RG 6/U CABLE + CAT 5E TRIAMESE DESCRIPTION: 1Two RG 6/U Quad cables: • 18 AWG bare copper center conductor • Gas-injected foamed polyethylene insulation 1One, 4-pair, Cat 5E cable • Solid copper conductors • Polyethylene insulation 1Triamese construction APPLICATION: Residential Cabling with structured design for voice, data, video and any other high-speed application. PROPERTIES: Overall Diameter: 0.823 x 0.3” Cable Weight per 1,000 feet: 90 lbs RoHS Standard lengths of 500 foot reels Braid Propagation Resistance or Product Coverage Capacitance Speed Diameter Insulation Code Conduct Conductor Diameter Impedance 820146 18 AWG 99.5 Ù/km 4.57 mm 60% - 40% 75 + 3Ù Conductor Diameter Number of Pairs Conductor Resistance Impedance 24 AWG 4 93.8 Ù/km 100 + 15Ù Condumex Wire and Cable Attenuation 53.1 pF/m Pair-to-Pair Capacitance Unbalance < 330 pF/100 m 82% MHz dB/100 m 55 211 300 550 750 1000 5.25 10.10 12.14 16.70 19.69 22.97 Properties at 100 m Frequency Attenuation PSNext MHz dB/100 m dB/100ft 53.3 4.1 4 47.3 6.5 10 44.3 8.2 16 35.4 17.0 62.5 32.3 22.0 100 th 2590 114 Street, Suite 200 - Grand Prairie, TX 75050 - (800) 925-9473 4-05 37 NOTES: Condumex Wire and Cable 5-05 2590 114th Street, #200 - Grand Prairie, TX 75050 (800) 925-9473 www.condumexinc.com