selectra 1/ 2/e
SELECTRA 1/ 2/E ÁCIDO ÚRICO TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME PREDILUITION: SLOPE BLANK: DELAY, MIN.TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: INCUBATION TIME: 37ºC ÁCIDO ÚRICO AUR ENDPOINT 546 nm mg/dL 1 0.00 mg/dL 25 mg/dL * 1 1 * * CUT OFF: PROZONE CHECK: REF.MALE LOW: REF.MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT.FACTOR: CORRELAT. OFFSET: * NO 2.5 7 1.5 6 * * * * * 1,000 0.000 mg/dL AUR NO 25 mL 250 µL 250 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENT BLANK: CAL. LOW LIMIT: CAL. HIGH LIMIT: FACTOR: (- 0.100 )ABS 3.000 ABS (- 0.100) ABS 3.000 ABS YES # 0.000 3,000 # LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENT BLANK: CAL. LOW LIMIT: CAL. HIGH LIMIT: FACTOR: (- 0.100 )ABS 3.000 ABS (- 0.100) ABS 3.000 ABS YES # 0.000 3,000 # 6 µL 5 µL 5 mL 0 µL 0 µL NO NO 4.5 MIN AUR NO 25 mL 250 µL 250 µL 6 µL 2 µL 4.5 MIN. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E ALBUMINA TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: INCUBATION TIME: 37 ºC ALBUMINA ALB ENDPOINT 620 nm g/dL 2 0.00 g/dL 6.00 g/dL * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO 3.5 5.5 3.5 5.5 * * * * * 1,000 0.000 g/dL ALB NO 25 mL 300 µL 301 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENT BLANK: CAL. L. LIMIT: CAL. H. LIMIT FACTOR: (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENT BLANK: CAL. L. LIMIT: CAL. H. LIMIT: FACTOR: (- 0.100 ABS) 3.000 ABS (- 0.100 ABS) 3.000 ABS YES # (-0.100 )ABS 3,000 # 3 µL 2 µL 5 mL 0 µL 0 µL No No 11.5 MIN. ALB NO 25 mL 300 µL 301 µL 3 µL 2 µL 11.5 MIN. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E AMILASE TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37 ºC AMILASE AMIL KINETIC 405 nm U/L 0 10 U/L 1500 U/L * * * * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO 30 130 30 130 * * * * * 1,000 0.000 U/L AMI NO 25 mL 250 µL 253 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENT BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 0.600 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENT BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 0.600 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # 5 µL 3 µL 5 mL 0 µL 0 µL NO NO 50, 186 SEC. AMILASE NO 25 mL 250 µL 253 µL 5 µL 3 µL 50,1860 SEC. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E BILIRRUBINA DIRETA TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: 37ºC BILIRRUBINA DIRETA BD ENDPOINT 525 nm mg/dL 2 0 18 * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 mg/dL BIL YES 25 mL 400 µL 401 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.200 ABS 3.000 ABS YES # * 25 µL 12 µL 5 mL 40 µL 40 µL NO NO 6.5 MIN. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: ( 11) 3429-2555/ [email protected] SELECTRA1/ 2/E BILIRRUBINA TOTAL TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: 37ºC BILIRRUBINA TOTAL BT ENDPOINT 546 nm mg/dL 2 0 18 * 1 1 * * CUT OFF: * PROZONE CHECK: NO REF. MALE LOW: * REF. MALE HIGH: * REF. FEMALE LOW: * REF. FEMALE HIGH: * REF. PED. LOW: * REF. PED HIGH: * CONTROL 1: * CONTROL 2: * CONTROL 3: * CORRELAT. FACTOR: 1,000 CORRELAT. OFFSET: 0.000 mg/dL BIL YES 25 mL 400 µL 401 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 25 µL 12 µL 5 mL 40 µL 40 µL NO NO 6.5 MIN. 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.200 ABS 3.000 ABS YES # * * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E CÁLCIO ARSENAZO TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC CÁLCIO ARSENAZO CAL ARS ENDPOINT 620 nm mg/dL 1 0.0 mg/dL 30 mg/dL * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO 8.5 10.5 8.5 10.5 * * * * * 1,000 0.000 mg/dL CAL ARS NO 5 mL 300 µl 303 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100 )ABS 3.000 ABS (-0.100 )ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # 6 µL 3 µL 5 mL 0 µL 0 µL NO NO 4.5 MIN CAL ARS NO 5 mL 300 µl 303 µL 25 µL 12 µL 4.5 MIN * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: ( 11) 3429-2555/ [email protected] SELECTRA 1/ 2/E CÁLCIO TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC CÁLCIO CAL ENDPOINT 578 nm mg/dL 1 0.0 mg/dL 20 mg/dL * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO 8.8 11 8.8 11 * * * * * 1,000 0.000 mg/dL CAL NO 25 mL 200 µl 200 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.200 ABS 3.000 ABS YES # # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.200 ABS 3.000 ABS YES # # 4 µL 3 µL 25 mL 200 µL 200 µL NO NO 11.5 MIN. CAL NO 25 mL 300 µL 303 µl 3 µL 2 µL 11.5 min. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E COLESTEROL HDL TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC COLESTEROL HDL HDL ENDPOINT 505 nm mg/dL 0 0 150 PADRÃO 1 1 40 * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: HDL NO 25 mL 230 µL 243 µL LINEARITY LIMIT: 15% LOW ABSORBANCE: (-0.100) ABS HIGH ABSORBANCE: 3.000 ABS R. ABS. L. LIMIT: (-0.100) ABS R. ABS. H. LIMIT: 3.000 ABS R. ABS. DEVIATION 3.000 ABS REAGENTE BLANK: YES # CAL. L. LIMIT CAL. L. LIMIT (-0.100 )ABS CAL. H. LIMITCAL. H. LIMIT3.000 ABS FACTOR: # 23 µL 20 µL 5 mL 0 µL 0 µL NO NO 11.5 MIN. HDL NO 25 mL 230 µL 243 µL 23 µL 20 µL 11.5 MIN. LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: * NO * * * * * * * * * 1,000 0.000 mg/dL 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: ( 11) 3429-2555/ [email protected] SELECTRA 1 / 2/E COLESTEROL HDL DIRETO TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: 37ºC HDL HDL TWO POINT 578 nm mg/dL 0 0 130 * * * * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 mg/dL HDL NO 25 mL 270 µl 275 µL POINT 1.2 LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 6.236 SEC (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # 3µL 2 µL 5 mL 90 µL 85 µL NO NO * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555/ [email protected] SELECTRA 1 / 2/E COLESTEROL TOTAL TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC COLESTEROL TOTAL COL ENDPOINT 505 nm mg/dL 0 30 500 * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO 0 200 0 200 * * * * * 1,000 0.000 mg/dL COL NO 25 mL 300 µl 301 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100 )ABS 3.000 ABS (-0.100 )ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.200 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # 3 µL 2 µL 5 mL 0 µL 0 µL NO NO 11.5 MIN. COL NO 25 mL 300 µL 301 µL 3 µL 2 µL 11.5 MIN. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: ( 11) 3429-2555/ [email protected] SELECTRA1/ 2/E CK MB TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC CK MB CK MB KINETIC 340 nm U/L 0 0 600 * * * * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: NO NO * * * * * * * * * 1,000 0.000 U/L CK MB NO 25 mL 250 µL 252 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 10% (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS 8254 LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 10% (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 3.000 ABS YES # 8254 10 µL 8 µL 5 mL 0 µL 0 µL NO NO 226.196 SEC CK MB NO 25 mL 250 µL 252 µL 10 µL 8 µL 226.196 SEC. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E CK TOTAL TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC CK TOTAL CK KINETIC 340 nm U/L 0 0 1000 * * * * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: NO NO * * * * * * * * * 1,000 0.000 U/L CK Total NO 25 mL 250 µL 265 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 10% (-0.100) ABS 3.000 ABS 1.100 ABS 3.000 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 10% (-0.100) ABS 3.000 ABS 1.100 ABS 3.000 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # 10 µL 5 µL 5 mL 0 µL 0 µL NO NO 129.293 SEC. CK Total NO 25 mL 250 µL 265 µL 10 µL 5 µL 129. 293 SEC. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: ( 11) 3429-2555/ [email protected] SELECTRA 1/ 2/E CREATININA TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC CREATININA CRE TWO POINT 505 nm mg/dL 1 0.0 mg/dL 10 mg/dL * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 mg/dL CRE NO 25 mL 230 µl 248 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # 23 µL 20 µL 5 mL 0 µL 0 µL NO NO 24, 77 SEC. CRE NO 25 mL 230 µL 248 µL 23 µL 20 uL 24, 77 SEC. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555/ [email protected] SELECTRA1/ 2/E DESIDROGENASE LÁCTICA TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37 ºC LDH UV LDH KINETIC 340 nm U/L 0 0 U/L 1500 U/L * * * * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 U/L LDH NO 25 mL 250 µL 253 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS 1.000 ABS 3.000 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 Abs # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.000 ABS 3.000 ABS 1.000 ABS 3.000 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # 5 µL 2 µL 5 mL 0 µL 0 µL NO NO 50,186 SEC. LDH NO 25 mL 250 µL 253 µL 5 µL 2 µL 50,186 SEC. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/2/E FERRO CROMAZUROL TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37 ºC FERRO CRX FE ENDPOINT 620 nm ug/dL 0 0 500 * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: NÃO NÃO 0 0 0 0 0 0 * * * 1,000 0.000 FERROCRX NO 25 mL 250 µL 255 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100) ABS 3.000 ABS (-0.100) ABS (-0.100) ABS (-0.100) ABS (-0.100) ABS (-0.100) ABS (-0.100) ABS LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS YES # (-0.100) ABS 3.000 ABS # 10 µL 8 µL 5 mL 0 µL 0 µL NO 4.5 MIN. FERROCRX NO 25 mL 250 µL 255 µL 10 µL 8 µL 4.5 MIN. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA1/ 2/E FERRO TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: DELAY, MIN. TIME: 37 ºC FERRO FE ENDPOINT 576 nm µg/dL 0 10 800 * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: NO NO 0 0 0 0 0 0 * * * 1,000 0.000 FERRO NO 25 mL 200 µL 200 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT -0.1 3,000 -0.1 1,000 YES (-0.010) * * 50 µL 50 µL 5 mL 10 µL 10 µL NO 6.5 MIN * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/2/E FOSFATASE ALCALINA TEMPERATURE: 37ºC NAME: FOSF. ALC. ABBR. NAME: FAL MODE: KINETIC WAVELENGTH: 405 nm UNITS: U/L DECIMALS: 0 LOW CONC: 15 U/L HIGH CONC: 1200 U/L CALIBRATOR NAME* REPEAT: * NUMBER: * CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: FOSF. ALC. NO 25 mL 250 µL 253 µL 5 µL 2 µL 5 mL 0 µL 0 µL No No 50, 186 SEC. FOSF. ALC. NO 25 mL 250 µL 253 µL 5 µL 2 µL 50, 186 SEC. CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 U/L LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.500 ABS 0.300 ABS YES # 6599.68 LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.500 ABS 0.300 ABS YES # 6599.68 * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E FÓSFORO TEMPERATURE: 37ºC NAME: FÓSFORO ABBR. NAME: FOS MODE: ENDPOINT WAVELENGTH: 340 nm UNITS: mg/dL DECIMALS: 0 LOW CONC: 0 HIGH CONC: 15 CALIBRATOR NAM * REPEAT: 1 NUMBER: 1 CONCENTRATION* INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: FOS NO 25 mL 300 µL 301 µL 3 µL 2 µL 5 mL 0 µL 0 µL No No 11.5 MIN FOS NO 25 mL 300 µL 301 µL 3 µL 2 µL 11.5 MIN. CUT OFF: * PROZONE CHECK: NO REF. MALE LOW: * REF. MALE HIGH: * REF. FEMALE LOW: * REF. FEMALE HIGH: * REF. PED. LOW: * REF. PED HIGH: * CONTROL 1: * CONTROL 2: * CONTROL 3: * CORRELAT. FACTOR 1,000 CORRELAT. OFFSET 0.000 mg/dL LOW ABSORBANCE: (-0.100) ABS HIGH ABSORBANCE: 3.000 ABS R. ABS. L. LIMIT: (-0.100) ABS R. ABS. H. LIMIT: 3.000 ABS REAGENTE BLANK: YES # CAL. L. LIMIT (-0.100 )ABS CAL. H. LIMIT 3.000 ABS FACTOR: 16817 LOW ABSORBANCE: (-0.100) ABS HIGH ABSORBANCE: 3.000 ABS R. ABS. L. LIMIT: (-0.100) ABS R. ABS. H. LIMIT: 3.000 ABS REAGENTE BLANK: YES # CAL. L. LIMIT (-0.100 )ABS CAL. H. LIMIT 3.000 ABS FACTOR: 16817 * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E GAMA GT TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC GAMA GT GGT KINETIC 405 nm U/L 0 0 U/L 700 U/L * * * * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 U/L GAMA GT NO 25 mL 260 µL 265 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 1.600 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS 16817 LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.600 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS 16817 13 µL 8 µL 5 mL 0 µL 0 µL NO NO 77, 132 SEC. GAMA GT NO 25 mL 260 µL 265 µL 13 µL 8 µL 77, 132 SEC. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11 ) 3429-2555/ [email protected] SELECTRA 1/ 2/E GLICOSE TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC GLICOSE GLI ENDPOINT 505 nm mg/dL 0 0.0 mg/dL 400 mg/dL * * * * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO 70 99 70 99 * * * * * 1,000 0.000 mg/dL GLI NO 25 mL 300 µl 301 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100 )ABS 3.000 ABS (-0.100 )ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.200 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # 3 µL 2 µL 5 mL 0 µL 0 µL NO NO 11.5 MIN. GLI NO 25 mL 300 µL 301 µL 3 µL 2 µL 11.5 MIN. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11 ) 3429-2555/ [email protected] SELECTRA 1/2/E LACTATO TEMPERATURE: 37ºC NAME: LACTATO ABBR. NAME: LAC MODE: ENDPOINT WAVELENGTH: 540 nm UNITS: mmol/L * DECIMALS: 0 LOW CONC: * HIGH CONC: * CALIBRATOR NAME* REPEAT: * NUMBER: * CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: MAG NO 25 mL 300 µL 301 µL 3 µL 2 µl 5 mL 0 µL 0 µL No No 11.5 MIN. LAC NO 25 mL 300 µL 301 µL 3 µL 2 µL 11.5 MIN CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 U/L LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/ 2/E LIPASE TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: 37ºC LIP LIP TWO POINT 578 nm U/L 0 3 300 * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 mg/dL LIP NO 25 mL 220 µL 220 µL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: FACTOR: 0.000 ABS 3.000 ABS 0.000 ABS 3.000 ABS YES # # 4 µL 2 µL 5 mL 110 µL 110 µL NO NO 130, 130 SEC. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA 1/2/E MAGNÉSIO TEMPERATURE: NAME: ABBR. NAME: MODE: WAVELENGTH: UNITS: DECIMALS: LOW CONC: HIGH CONC: CALIBRATOR NAME: REPEAT: NUMBER: CONCENTRATION: INTERVAL: DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: 37ºC MAGNÉSIO MAG ENDPOINT 505 nm mg/dL 0 0 4.5 * 1 1 * * CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 U/L MAG NO 25 mL 300 µL 301 µL LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% (-0.100) ABS 3.000 ABS (-0.100) ABS 3.000 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.000 ABS 3.000 ABS 0.000 ABS 1.200 ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # 3 µL 2 µL 5 mL 0 µL 0 µL NO NO 4.5 MIN. MAG NO 25 mL 300 µL 301 µL 3 µL 2 µL 4.5 MIN. * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555 / [email protected] SELECTRA 1/ 2/E PROTEÍNAS TOTAIS TEMPERATURE: 37ºC NAME: PROTEÍNAS TOTAIS ABBR. NAME: PT MODE: ENDPOINT 546 nm WAVELENGTH: UNITS: g/dL DECIMALS: 1 LOW CONC: 0 HIGH CONC: 11 CALIBRATOR NAME * REPEAT: 1 NUMBER: 1 CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: PT NO 25 mL 300 µL 301 µL 6 µL 5 µL 5 mL 0 µL 0 µL NO NO 11.5 MIN. PT YES 25 mL 300 µL 301 µL 6 µL 5 µL 11,5 MIN. CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: NO NO * * * * * * * * * 1,000 0.000 g/dL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100 )ABS 3.000 ABS (-0.100 )ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (- 0.100) ABS 3.000 ABS (- 0.100) ABS 0.300 ABS YES (- 0.100) ABS 3,000 # * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected] SELECTRA1/ 2/E PROTEÍNA URINÁRIA TEMPERATURE: 37ºC NAME: PROTURI ABBR. NAME: PROTURI ENDPOINT MODE: WAVELENGTH: 620 nm UNITS: mg/dL DECIMALS: 1 LOW CONC: 0 HIGH CONC: 100 CALIBRATOR NAME * REPEAT: 1 NUMBER: 1 CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: PROTURI YES 25 mL 240 µL 248 µL 12 µL 3 µL 5 mL 0 µL 0 µL No No 11.5 MIN. PROTURI YES 25 mL 240 µL 248 µL 12 µL 3 µL 11,5 MIN. CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: NO NO * * * * * * * * * 1,000 0.000 g/dL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100 )ABS 3.000 ABS (-0.100 )ABS 0.500 YES # (-0.100 )ABS 3.000 ABS # LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (- 0.100) ABS 3.000 ABS (- 0.100) ABS 0.500 ABS YES (- 0.100) ABS 3,000 # * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555 / [email protected] SELECTRA 1/ 2/E TGP / ALT TEMPERATURE: 37ºC NAME: TGP / ALT ABBR. NAME: ALT MODE: KINETIC WAVELENGTH: 340 nm UNITS: U/L DECIMALS: 0 LOW CONC: 0 HIGH CONC: 440 CALIBRATOR NAME * REPEAT: * NUMBER: * CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: TGP / ALT NO 25 mL 230 µl 248 µL 23 µL 5 µL 5 mL 0 µL 0 µL NO NO 50, 186 SEC. TGP / ALT NO 25 mL 230 µL 248 µL 23 µL 5 µL 50, 186 SEC. CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 U/L LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.800 ABS 3.000 ABS 1.000 ABS 3.000 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS (-1750.3) LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.800 ABS 3.000 ABS 1.000 ABS 3.000 ABS 0.200 ABS YES # (-0.100 )ABS 3.000 ABS (-1750.3) * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555 / [email protected] SELECTRA 1/2/E AST / TGO TEMPERATURE: 37ºC NAME: ASTGOT ABBR. NAME: AST MODE: KINETIC WAVELENGTH: 340 nm UNITS: U/L DECIMALS: 0 LOW CONC: 0 HIGH CONC: 440 CALIBRATOR NAME * REPEAT: 1 NUMBER: 1 CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: ASTGOT NO 25 mL 250 µL 265 µL 25 µL 10µL 5 mL 0 µL 0 µL NO NO 103, 133 SEC. ASTGOT NO 25 mL 250 µL 265 µL 25 µL 10 µL 103, 133 SEC. CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 U/L LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.800 ABS 3.000 ABS 1.000 ABS 3.000 ABS 0.200 ABS YES # (-0.100 )ABS 3.000 ABS (-1565.3) LINEARITY LIMIT: LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 15% 0.800 ABS 3.000 ABS 1.000 ABS 3.000 ABS 0.200 ABS YES # (-0.100 )ABS 3.000 ABS (-1565.3) * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555 / [email protected] SELECTRA 1/2/E TRIGLICÉRIDES TEMPERATURE: 37ºC NAME: TRIGLICÉRIDES ABBR. NAME: TRIG MODE: ENDPOINT WAVELENGTH: 505 nm UNITS: mg/dL DECIMALS: 0 LOW CONC: 0 1100 HIGH CONC: CALIBRATOR NAME * REPEAT: 1 NUMBER: 1 CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: TRIG No 25 mL 300 µL 301 µL 3 µL 2 µL 5 mL 0 µL 0 µL NO NO 11.5 MIN. TRIG NO 25 mL 300 µL 301 µL 3 µL 2 µL 11,5 MIN. CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: NO NO * * * * * * * * * 1,000 0.000 U/L LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (-0.100 )ABS 3.000 ABS (-0.100 )ABS 3.000 ABS YES # (-0.100 )ABS 3.000 ABS # LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: (- 0.100) ABS 3.000 ABS (- 0.100) ABS 0.300 ABS YES 0.000 3,000 # * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL SAC: (11) 3429-2555 / [email protected] SELECTRA 1/ 2/ E URÉIA UV TEMPERATURE: 37ºC URÉIA UV NAME: ABBR. NAME: URÉIA MODE: KINETIC WAVELENGTH: 340 nm UNITS: mg/dL DECIMALS: 0 LOW CONC: 0 HIGH CONC: 250 CALIBRATOR NAME * 1 REPEAT: NUMBER: 1 CONCENTRATION: * INTERVAL: * DUAL MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: R2 BOTTLE: NORMAL VOLUME: RERUN VOLUME: PREDILUITION: SLOPE BLANK: DELAY, MIN. TIME: MONO MODE NAME: SAMPLE BLANK: R1 BOTTLE: NORMAL VOLUME: RERUN VOLUME: SAMPLE: NORMAL VOLUME: RERUN VOLUME: DELAY, MIN. TIME: URÉIA NO 25 mL 300 µL 303 µL 3 µL 2 µL 5 mL 0 µL 0 µL No NO 77, 132 SEC. URÉIA NO 25 mL 300 µL 301 µL 3 µL 2 µL 77, 132 SEC. CUT OFF: PROZONE CHECK: REF. MALE LOW: REF. MALE HIGH: REF. FEMALE LOW: REF. FEMALE HIGH: REF. PED. LOW: REF. PED HIGH: CONTROL 1: CONTROL 2: CONTROL 3: CORRELAT. FACTOR: CORRELAT. OFFSET: * NO * * * * * * * * * 1,000 0.000 mg/dL LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: CAL. L. LIMIT CAL. H. LIMIT FACTOR: 0.800 ABS 3.000 ABS 1.000 ABS 3.000 ABS 0.300 ABS YES # (-0.100 )ABS 3.000 ABS # LOW ABSORBANCE: HIGH ABSORBANCE: R. ABS. L. LIMIT: R. ABS. H. LIMIT: R. ABS. DEVIATION REAGENTE BLANK: FACTOR: 0.800 ABS 3.000 ABS 1.000 ABS 3.000 ABS 0.200 ABS YES # # * Indica que os dados serão inseridos pelo operador. # Calculado pelo aparelho. Para esclarecimentos de dúvidas, favor entrar em contato com o SAC. Assessoria Técnica KATAL: SAC: (11) 3429-2555/ [email protected]