SSF
Transcription
SSF
SSF series Fail-safe Light curtain sensors ● Safety ensured in the unlikely event of failure Fail-safe feature ● Enhanced safety with high performance and userfriendliness Multifunctional ● 20 - 40 ㎜ beam intervals available Wide variation Output relay turns OFF (safe side) when failure occurs Light Curtain Sensors Light emitting circuit damaged Receiver Transmitter Light receiving circuit damaged Light emitting element damaged Light sensitive element damaged Synchronization/ Anti Interference line Disconnection damaged Output circuit damaged Control unit Disconnection Output relay contact welded Output circuit broken Power supply line broken 480 SSF Optical axis alignment indicator for ease of use Beam interval: Optical axis alignment indicator lamps for the top (H) and bottom (L) optical axes are provided at the center of the receiver for assistance to adjust and check the optical axes. 20 / 40mm Minimum detection objec t: φ 30mm /φ 50mm Detecting distance 2 sets of sensors mounted adjacently or face-to-face without interference 5m Anti Interference feature counteracts the installation restrictions and ensures reliability. Relay contacts used for all outputs for enhanced fail-safe feature Fail-safe automatic sensitivity compensation feature provided Contact relays are used for control and lockout outputs. Failure-safe is taken into consideration for failure mode as well. Easy maintenance thanks to robust and slim case provided with spatter resistant plate Robust aluminum drawn case is employed. Front cover that protects the lenses from scattered oil dust or spatters may be removed for cleaning and replacement. CHECK switches provided for simple operation check Light Curtain Sensors After the optical axis alignment, turn the power off once and back on. The automatic sensitivity compensation feature is enabled and the sensitivity is set at the optimum. If the lens is soiled with dirt or dust, or even after the soil is removed the sensitivity is automatically compensated to achieve the optimum sensitivity. The CHECK switches on the control unit allow simple operation check and lockout release check. Wide variation Detecting width 2520mm A wide range of sizes from 4 (120㎜) to 64 optical axes (2520 ㎜) Detecting width 120mm offered for various applications (compatible to supersized machines). 481 SSF ■ Type Series name Detecting distance SSFT200 5m SSFT400 ● Detecting width 140㎜ 300㎜ 460㎜ 620㎜ 780㎜ 940㎜ 1100㎜ 1260㎜ 120㎜ 280㎜ 440㎜ 600㎜ 760㎜ 920㎜ 1080㎜ 1240㎜ Set model No. of Optical axis No. light axes interval 8 SSF-T8C 16 SSF-T16C 24 SSF-T24C 32 SSF-T32C 20㎜ 40 SSF-T40C 48 SSF-T48C 56 SSF-T56C 64 SSF-T64C 4 SSF-T404C 8 SSF-T408C 12 SSF-T412C 16 SSF-T416C 40㎜ 20 SSF-T420C 24 SSF-T424C 28 SSF-T428C 32 SSF-T432C Detecting object Opaque φ30㎜ or more Opaque φ50㎜ or more Set model description Light Curtain Sensors Transmitter: SSF-TL □□□ ⎫ ⎬ □ indicates the number of optical axes Receiver: SSF-TR □□□ ⎭ Control unit: SSF-C Cord with connector for transmitter: SS-H5L Cord with connector for receiver: SS-H5R ● Products with countermeasures provided in the event of faulty operation due to spatter or arc light are available (SSF-T400 Series). Transmitter: SSF-TL4 □□ -HP Receiver: SSF-TR4 □□ A-HP Set model: SSF-T4 □□ AC-HP ● 2 output type Products with two 1a contact outputs are available on request. ■ Optional Parts ● Corner reflector Deflects light at a corner. Model SSM-F8N SSM-F16N SSM-F24N SSM-F32N SSM-F40N SSM-F48N SSM-F56N SSM-F64N Applicable model (*) SSF-T8 SSF-T16 SSF-T24 SSF-T32 SSF-T40 SSF-T48 SSF-T56 SSF-T64 (Note) The detecting distance will be reduced to 4m max. *May also be used for the SSF-T400 Series. Note the number of axes and the overall length of the reflector. See P.491 for details. ● Front cover Model: SSF-K□* □ indicates the number of optical axes (unified price for all models). 482 SSF ■ Rating/Performance/Specification SSF-T400 series (with 20mm beam interval) SSF-T200 series (with 40mm beam interval) Through beam Series Detection method Detecting distance Detecting object Optical axis interval No. of light axes Detecting width Power supply Current consumption Control output Lockout output 5m or less 20㎜ (See “Type.”) 24VDC ±10% 300mA or less Output: Relay contact 1a (2 relay outputs in series) Rating: 250V 3A AC resistive load 30V 2A DC resistive load Output mode Operation mode Response time Activated when light beams of all axes are received Light blocking: 20 ms or less / Light reception: 30 ms or less Output: Relay contact 1a Rating: 250V 1A AC resistive load 30V 1A DC resistive load Output mode Operation mode Response time Light source Light-sensitive element ON for normal operation, OFF for failure 50ms or less Infrared LED (wavelength 880nm) Photo IC Circuit failure indicator (Orange) Synchronization failure indicator (Red) RUN indicator (Green) Slave indicator (Orange) Transmitter Receiver Top optical axis alignment indicator (Green)/Disturbing light indicator (Orange) /Bottom optical axis alignment indicator (Green) Operation indicator (Red)/Unstable light reception indicator (Orange) /Stable light reception indicator (Green) Control POWER (Green) OUTPUT (Yellow) SENSOR FAIL (Red) LOCK OUT (Red) unit Auxiliary functions Switch Mutual interference prevention feature for adjacent installation, automatic sensitivity compensation Control unit: CHECK switch Material Transmitter/Receiver: Aluminum / Front cover: Acrylic Control unit: Polycarbonate Connection Attached cable with connector φ6.8 ㎜ 4 cores cable / 0.2 m Control unit: Terminal block type with M3.5㎜ screws Weight Sensor Control unit Accessory Light Curtain Sensors Indicator Opaque φ50㎜ or more. 40㎜ Opaque φ30㎜ or more. Approx. 230g - 1000g Approx. 160g Cable with connector 5 m, mounting brackets, operation manual ■ Environmental Specification Ambient light Ambient temperature Ambient humidity Vibration Protective structure Dielectric withstanding Insulation resistance 9000lx or less –10 - +55 °C (non-freezing) 35-85%RH (non-condensing) 10-55 Hz / 1.5 ㎜ double amplitude / 2 hours each in 3 directions Sensor: IP65 / Control unit: IP40 1500 VAC for 1 minute 500 VDC, 20 MΩ or higher. ■ Optional Parts Cable with connector (10 m) For transmitter: SS-H10L (gray covering) For receiver: SS-H10R (black covering) 483 SSF Transmitter ■ Input/Output Circuit and Connection Sensor Lead colors Control unit SSF-C 7 8 Anti Interference input 9 0V (Blue) 10 +V (Brown) 11 Synchronization line 12 5 2 4 1 6 3 IN (Black) Internal circuit Receiver M/S line ( Purple) (Orange/purple striped) 24VDC 0V OUT Control output OUT LOCK OUT Lockout output LOCK OUT (Circled numbers show pin Nos.) ■ Indicators and Operation The indicators provided for the transmitter, receiver and control unit and their operation are outlined as follows: Transmitter Control unit Light Curtain Sensors Indicator location ⑪ ⑫ ④ ③ ⑩ ⑨ ⑧ ⑬ ⑭ ② Control unit Receiver Transmitter Type No. 484 Receiver ① ② Indicator name ① Color Green Orange Red Orange Green Orange Red Green Orange Green ⑦ ⑥ ⑤ Normal operation Illuminated ⑫ RUN indicator Slave indicator Synchronization failure indicator Circuit failure indicator Stable light reception indicator Unstable light reception indicator Operation indicator Bottom optical axis alignment indicator Disturbing light indicator Top optical axis alignment indicator Power indicator Control output indicator ⑬ Sensor failure indicator Not illuminated Illuminated when beam of top axis is received Green Illuminated when power is supplied Yellow Illuminated when beam of any axis is unstably received Red Not illuminated ⑭ Lockout output indicator Red Not illuminated ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ Illuminated on slave Not illuminated Not illuminated Failure description and indication Flashes to indicate transmitter failure Flashes to indicate abnormal operation on slave Flashes to indicate broken synchronization line Flashes to indicate circuit failure Illuminated when beams of all axes are stably received Illuminated when beam of any axis is unstably received Flashes to indicate receiver failure Illuminated when beam of any axis is received/blocked Illuminated when beam of bottom axis is received Flashes to indicate broken synchronization line/transmitter failure Illuminated when disturbing light/noise is detected Flashes to indicate receiver failure Illuminated when power supply is down — Illuminated to indicate sensor failure/unconnected/power short circuit Illuminated to indicate lockout output SSF ■ Connection Examples Connection for standalone use ● ● Connection for Anti Interference Connect as shown below for adjacent installation of two sets of sensors. BRN BLU 10 11 12 7 8 9 Slave BLK VIO ORG/VIO BRN BRN BLU BLU 10 11 12 7 8 9 Control unit SSF-C Control unit SSF-C Control output (relay contact output) 4 5 6 OUT +24 LOCKOUT Lockout output (relay contact output) ORG/VIO BLK Receiver VIO ORG/VIO Receiver BRN BLU Transmitter BLU Receiver BRN Master ORG/VIO Transmitter BLK Transmitter VIO ORG/VIO ORG/VIO BRN BLU 10 11 12 7 8 9 (Mutual Interference line) Control unit SSF-C 4 5 6 4 5 6 OUT +24 LOCKOUT OUT +24 LOCKOUT 1 2 3 1 2 3 1 2 3 OUT 0V LOCKOUT OUT 0V LOCKOUT OUT 0V LOCKOUT DC24V Power supply 0V DC24V Power supply 0V Be sure to use the same power supply for the master and slave control units. The terms master and slave are only used for convenience in distinguishing between two units of the same model that function differently depending on the wiring. The unit with its Anti Interference line connected to Terminal 9 is referred to as the master. Do not connect the transmitter and receiver to separate control units. For wiring length, see Cable Extension. ● ● ● ● ■ Perfomance Curves (Typical) Response Curves:Longitudinal Gap ● (All models) ● Response Curves:Lateral Gap Response Curves:Tilt Angle Light Curtain Sensors ● (All models) (All models) Receiver Detecting distance L(m) 5 4 7 θ 6 L 5 5 4 4 3 3 Detecting distance L(m) Detecting distance L(m) Transmitter 3 Displace receiver Transmitter fixed α Transmitter fixed 2 1 1 300 200 100 0 100 200 300 300 200 100 0 100 200 300 20 15 10 5 0 5 10 15 20 Angle θ (degrees) Position α (mm) Position α (mm) ● 2 L 1 L 2 Receiver Displace receiver α Receiver Response Curves:Minimum Detecting Object SSF-T200 series SSF-T400 series 30 50 20 40 5m A (transmitter) A C B (midway) 5m L R Detection object Detection object L B C (receiver) A (transmitter) A C B (midway) R B C (receiver) 485 SSF ■ Indication/Operation Matrix The operations of the indicators and outputs of the sensor and control unit are as shown in the table below: ●:Illuminated Sensor Transmitter indicator Receiver indicator Normal operation Item Stable light reception Light blocking Disturbing light (when detected) Light emitting element damaged Light sensitive element damaged Light emitting circuit damaged ● ● ● ○ ● ○ ● CIR SYNC CIR NOISE SYNC ▲ △ ● ○ ● ● ● ○ SLV RUN OP UNSTB STB ● ● ▲ △ ● ▲ △ CIR SYNC CIR NOISE SYNC ▲ △ ● ○ ● ○ ● ● SLV RUN OP UNSTB STB ● ● ● ○ ● ○ ● ○ CIR SYNC CIR NOISE SYNC ▲ △ ● ○ ● ● ● ○ SLV RUN OP UNSTB STB ● ● ▲ △ ● ▲ △ CIR SYNC CIR NOISE SYNC ▲ △ ● ○ ● ○ ● ● SLV RUN OP UNSTB STB ● ● ● CIR SYNC CIR NOISE SYNC RUN OP UNSTB STB ● ● CIR NOISE SYNC OP UNSTB STB ▲ △ Sensor SLV Light receiving circuit damaged Failure Light Curtain Sensors Output circuit damaged ● ● CIR SYNC ▲ △ ● ○ SLV RUN ● ● ▲ △ ▲ △ ▲ △ CIR SYNC CIR NOISE SYNC Output line broken ▲ △ ● ○ ▲ △ ▲ △ ▲ △ SLV RUN OP UNSTB STB Transmitter power ● ● ● ● CIR SYNC CIR NOISE SYNC supply line broken ● ● SLV RUN OP UNSTB STB Receiver power supply line broken Synchronization line broken Anti Interference ● ● ● ● ● CIR SYNC CIR NOISE SYNC ▲ △ ● ○ ● ● ● SLV RUN OP UNSTB STB ● ● ● ● CIR SYNC CIR NOISE SYNC ▲ △ ● ○ SLV RUN OP UNSTB STB ● ● CIR SYNC CIR NOISE SYNC SLV RUN OP UNSTB STB ● line broken (slave)* Relay contact Control unit welded Circuit damaged Power supply line broken Power supply cut off ● ● ● ● ● CIR SYNC CIR NOISE SYNC ▲ △ ● ○ ▲ △ ▲ △ ▲ △ SLV RUN OP UNSTB STB ● ● ● ● ● CIR SYNC CIR NOISE SYNC ▲ △ ● ○ ▲ △ ▲ △ ▲ △ SLV RUN OP UNSTB STB ● ● ● ● ● CIR SYNC CIR NOISE SYNC ● ● ● ● ● SLV RUN OP UNSTB STB :Flashing ●:Unilluminated △:Operation ▲:Operation depending on situation Indicator ● ○POWER ●OUTPUT ●FAIL ●LOCKOUT ● ○POWER ● ○OUTPUT ●FAIL ●LOCKOUT ○POWER ● ○OUTPUT ● ●FAIL ●LOCKOUT ○POWER ● ○OUTPUT ● ●FAIL ●LOCKOUT ○POWER ● ○OUTPUT ● ○FAIL ● ●LOCKOUT ○POWER ● ○OUTPUT ● ○FAIL ● ●LOCKOUT ○POWER ● ○OUTPUT ● ○FAIL ● ●LOCKOUT ○POWER ● ○OUTPUT ● ○FAIL ● ●LOCKOUT ○POWER ● ○OUTPUT ● ○FAIL ● ●LOCKOUT ○POWER ● ○OUTPUT ● ○FAIL ● ●LOCKOUT ○POWER ● ○OUTPUT ● ○FAIL ● ●LOCKOUT ○POWER ● ●OUTPUT ●FAIL ○LOCKOUT ● ○POWER ● ●OUTPUT ●FAIL ○LOCKOUT ● ●POWER ●OUTPUT ●FAIL ●LOCKOUT Control unit Control output Lockout output Locked Locked Locked Locked Locked Locked Welded (Note) “Locked” refers to a state in which the output relay stays open due to circuit failure. (Note2) When the output circuit is damaged, the control output stays open. *When the Anti Interference line is broken in the master/slave configuration, the indicator on the slave flashes and the slave control output relay opens. 486 SSF ■ Control Unit Operation and Output The control unit outputs control and lockout signals depending on the detection by sensor and of different types of failure. ● Control output The control unit has duplicate circuits and the control output is composed of two output relays connected in series. Contact closed ● When light beams of all sensor axes are received (normal operation) Contact open When light beam of any axis is blocked When control unit lockout has been tripped ● When circuit damage or disconnection has occurred in components ● When power has been supplied with the sensor wired in a wrong way ● When the power supply, 0V, detection output, synchronization or Mutual Interference prevention line, etc. has been broken ● When the sensor output line has been short-circuited to the sensor power supply line (+V or 0V) of the control unit ● ● Lockout output Lockout is a feature that forces the control output relay to stay open when any internal failure has been detected. The control unit SSF-C has completely duplicated internal circuitry and any inconsistency found is regarded as failure, which trips lockout. In addition to lockout, the contact is opened for 2 seconds after power-up or when power supply line to the control unit has been broken. Light Curtain Sensors ● Condition of lockout (1) Inconsistency between the two control output relays When either of the output relays does not operate due to welding of contact (2) Inconsistency between the duplicate circuits When the operation of the two circuits do not agree due to failure in output circuit components of the control unit Notes on lockout release Lockout can be released by pressing the CHECK switch on the control unit. Before releasing lockout, identify and eliminate the cause of the lockout. If lockout cannot be released by pressing the CHECK switch, the control unit output circuit may be damaged or the output relay may be welded. Replace the control unit. Use the lockout output for monitoring. Do not use the output for control. For control, be sure to use the control output. 487 SSF For Correct Use ● ● ● ● Be sure to follow the instructions in the operation manual provided for correct use of the product. This sensor cannot be used as a power press safety device or other safety device to prevent death or injury that requires conformity to domestic or overseas standards or certification concerning protection of human body. Use for such purposes may lead to death or serious injury. This sensor is designed to detect an object passing over a certain point or line. When using this sensor for safety purposes except those mentioned above, ensure safe operation of the system as a whole including detection and control function. Cable Extension Figure 2 Receiver Transmitter Receiver Transmitter To extend the cable, use wires of at least 0.5 ㎜2 and limit the length as follows: ● Basic wiring :within 25 m between the transmitter/receiver and control unit (Figure 1) Figure 1 ● Synchronization wiring :within 50 m between transmitter and receiver (Figure 2) ● Power supply wiring for M/S wiring :within 25 m between the two 25m or less 25m or less control units (Figure 3) Synchronization line 50m or less black cable Slave unit gray cable Receiver Transmitter gray cable Receiver Light Curtain Sensors Transmitter Figure 3 Master unit black cable Control unit 2 Notes on installation ● ● 2 9 7 0V, 25m or less Interference prevention line 25m or less When installing the sensor, make sure that the ends of the transmitter and receiver with the cable are oriented either upward or downward. The sensor does not function if the transmitter and receiver are not oriented the same way. The tightening torque for installing the sensor should be up to 2 N・m. The tightening torque for installing the control unit with screws should be up to 0.78 N・m. Transmitter cable Receiver cable ● Wall, floor, machine, etc. Reflected light Receiver Any reflecting object (wall, floor, machine, etc.) within the detecting range between the transmitter and receiver may allow the light to go around the detection object, which is supposed to block the light, and reach the receiver. Choose the installation location carefully (Any glossy object such as stainless steel in the surrounding area must be at least 300㎜ away from the optical axes both vertically (up and down) and horizontally (left and right). Do not install the sensor in a place subject to steam, large amount of dust or direct exposure to water or rain. Transmitter ● Detection object Reflected light Wall, floor, machine, etc. 488 SSF ■ Dimensions (in ㎜) SSF-T200 Series transmitter/receiver SSF-T400 Series transmitter/receiver 15.5 15.5 28 28 25 13 25 13 29.5 4−5×7 9 29.5 4−5×7 6 9 28 6 48 20 40 A (Detecting width) Indicator Receiver (Green, Red, Green) Transmitter (Orange, Red) Indicator Receiver (Red, Orange, Green) Transmitter (Orange, Green) B C D Indicator Receiver (Green, Red, Green) Transmitter (Orange, Red) Indicator Receiver (Red, Orange, Green) Transmitter (Orange, Green) 20 26 9 6 210 φ14 (in ㎜) Dimensions of portions Model SSF-T8 SSF-T16 SSF-T24 SSF-T32 SSF-T40 SSF-T48 SSF-T56 SSF-T64 9 φ6.8 210 ● 26 (44) φ6.8 φ14 40 A 140 300 460 620 780 940 1100 1260 B 194 354 514 674 834 994 1154 1314 C 212 372 532 692 852 1012 1172 1332 D 224 384 544 704 864 1024 1184 1344 Model SSF-C (Control unit) Display panel 32 8.2 Cover 80 4.5 ● (in ㎜) Dimensions of portions Model SSF-T404 SSF-T408 SSF-T412 SSF-T416 SSF-T420 SSF-T424 SSF-T428 SSF-T432 SSF-T436 SSF-T440 SSF-T444 SSF-T448 SSF-T452 SSF-T456 SSF-T460 SSF-T464 A 120 280 440 600 760 920 1080 1240 1400 1560 1720 1880 2040 2200 2360 2520 B 194 354 514 674 834 994 1154 1314 1474 1634 1794 1954 2114 2274 2434 2594 C 212 372 532 692 852 1012 1172 1332 1492 1652 1812 1972 2132 2292 2452 2612 D 224 384 544 704 864 1024 1184 1344 1504 1664 1824 1984 2144 2304 2464 2624 Light Curtain Sensors (44) 6 A B C D (Detecting width) Cable with connector (accessory) 6.5 70 4.5 φ14 φ6.8 78 44 5m 6.5 22 Mounting hole dimensions SS-H5L (covering: gray) SS-H5R (covering: black) To download CAD data including dimensions, please visit www.takex-elec.co.jp/index_e.html. 489