K`ELECTRIC GmbH
Transcription
K`ELECTRIC GmbH
PRODUCT MANUAL 2014 K’ELECTRIC WE CONNECT TO PROTECT K’ELECTRIC WE CONNECT TO PROTECT 2 K’ELECTRIC The innovative brand in the area of protection system components. Our products stand for security, economic efficiency, user-friendly, save space and are extemly reliable. They protect people, buildings and equipment. We are with our flashing indicator and protection supervision technology leaders in the D0-fuse technic. Customers and partners profit from a product supply. Fast delivery and therefore efficiant time saving is guaranteed. 3 INDEX: Opto-electronic flashing indicator (OEFI) and plug-in systems Main Protection – intelligent fuse monitoring 5 6 1.0 D0-Fuse switch disconnector (for DIN rail mounting) 7 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 8 10 13 14 16 18 20 22 2.0 Bus Bar System 60mm 23 2.1 2.2 2.3 2.4 2.5 26 28 30 31 34 2.6 2.7 2.8 2.9 2.10 2.11 4 TYTAN® II TYTAN® II Main Protection TYTAN® II Flashing indicator plug and accessories TYTAN® I TYTAN® T (for DO and cylindrical fuses) TYTAN® T Main Protection (for DO and cylindrical fuses) CORON® 2 Fuse base Universal bus bar support Mains supply/hook type terminals D0-Bus mounting fuse base Component adapter D0-vertical fuse switch disconnector TYTAN® R (also suitable for cylindrical fuses) TYTAN R Main Protection Vertical fuse switch disconnector CORON® R NH-fuse switch disconnector MULTIVERT® NH-fuse switch disconnector type series KE NH-vertical fuse switch disconnector MULTIVERT® Front protection panels/Covers and cover shrouds 36 38 40 44 46 47 3.0 NH-fuse switch disconnector (for panel mounting) 48 3.1 Type series MULTIBLOC® 3.2 Type series KE 48 54 4.0 Sammelschienensystem 100/185mm 56 4.1 Bus bar support 100/185mm 4.2 MULTIVERT® vertical fuse switch disconnector MSL 100mm 4.3 MULTIVERT® vertical fuse NH-switch disconnector 185mm 56 57 59 5.0 Fuse accessories 62 6.0 Supervisory relays 65 7.0 Digital electric meter 69 8.0 Accessories 71 8.1 Wiring rails 8.2 Circuit diagram pockets 71 74 German Production & Technology OPTO- ELECTRONIC FLASHING INDICATOR AND PLUG- IN SYSTEM Opto -electronic flashing indicator (OEFI) The patented OEFI is a very reliable state of the art visual indicator signaling fuse failure. The blown fuse is immediately identifiable and remedial action for instantaneous reclosing can be taken. The fuse bridges the electronic control circuit In the event of a fault, the electronic circuit is triggered On switching off, the bridged control circuit will also be disconnected K’ELECTRIC WE CONNECT TO PROTECT range of operational slackening A quick fuse swap is possible since no cumbersome screwing-on is involved. “plug-in and reclose” Additionally, operator safety is enhanced. The fuse plug being extractable, physical contact with the fuse, which could have a temperature of 100° C is averted. area of manual dispersion The plug-in system with extractable fuse holders ensures continuous optimum contact pressure. Screw cap designs which can get loose, contribute to an avoidable dissipation loss of up to 10VA. begin of destructive damage area Plug- in system – quick and safe System relevant constant section work side contact pressure 5 MAIN PROTECTION INTELLIGENT FUSE MONITORING Our TYTAN® – Main protection switch has the capability of transmitting a floating signal via a relay contact. This is in addition to the visual opto- electronic function. Consequently fuse failure can be reliably identified and reported. Innovation! Safety plug with power measurement - super fast power rating by inserting the power measurement plug - min.-/max.-and average value available - can be retrofitted in all TYTAN ® R D0 rider Disconnectors current measurement easy, safe and inexpensive. 6 1.0 D0-FUSE SWITCH DISCONNECTOR for DIN rail mounting 1.1 TYTAN® II 1.2 TYTAN® II MAIN PROTECTION D0-Fuse switch disconnector - integrated flashing indicator (OEFI) - safety switch - codeable for ALL amperages - sealable - lockable D02 - Fuse switch disconnector with supervisory relay - integrated flashing indicator (OEFI) - safety switch - codeable for ALL amperages - sealable - lockable 1.3 TYTAN® II-FLASHING PLUG 1.4 TYTAN® I D0 - fuse plug with integrated flashing indicator suitable for insertion in TYTAN® II - Fuse switch disconnector and main protection switch. fuses included D01 - Fuse switch disconnector - integrated flashing indicator (OEFI) - universal-fuse plug - compatible LS-switch 1.5 TYTAN® T 1.6 TYTAN® T MAIN PROTECTION switch disconnector fuse for D0- and cylindrical fuses 10x38mm - only 4TE wide - integrated flashing indicator (OEFI) - universal-fuse plug Fuse switch disconnector for D0- cylindrical fuses 10x38mm with fuse and temperature control - only 4TE wide - integrated flashing indicator (OEFI) - universal-fuse plug 1.7 CORON® 2 1.8 D0-FUSE BASE E18 D0 - Fuse switch disconnector - integrated flashing indicator (OEFI) - universal-fuse plug - sealable - lockable with padlock - contact-protected execution - simple inscription possible 7 1.1 TYTAN® II 35mm DIN rail unit D0-Fuse switch disconnector - integrated flashing indicator (OEFI) - safety switch - codeable for ALL amperages - sealable - lockable Technical data: Classification Norm Suited for fuses Fuse switch disconnector IEC 947-3 D01: 1, 2, 4, 6, 10, 13, 16; D02: 20, 25, 32, 35, 40, 50, 63AgL, gG, aM Fire classification / track resistance Protection/ voltage contact protection Rated operational voltage Ue UL94 / V0, heating wire 960°C / CTI 600 IP 20 / finger and back of hand proof -AC -DC Rated operational current Ie Overvoltage category / degree of pollution 400V 1-pole 110V, 2-pole 220V 63A IV/3 (DIN VDE 0110) Rated impulse withstand voltage Uimp 6000V stainless steel cage clamp 1,5...35mm2; MD 4Nm, pozidriv Type of terminations Rated short circuit making capacity Icm Utilization category 8 10 26XX 10 28XX 50kAeff AC 22B, DC 21B Item-No. 10 2651 10 2652 10 2653 10 2641 10 2643 10 2851 10 2852 10 2853 10 2841 10 2843 Component width a in mm 27 54 81 54 108 54 81 108 81 135 German Production & Technology TYTAN® II D0–Fuse switch disconnector Fitted with opto-electronic flashing indicators for TYTAN® II K’ELECTRIC WE CONNECT TO PROTECT Item Item No. 10 2651 10 2652 10 2653 10 2641 10 2643 10 2851 10 2852 10 2853 10 2841 10 2843 1-pole 2-pole 3-pole 1-pole+N 3-pole+N 1-pole with auxiliary switch for switching status 2-pole with auxiliary switch for switching status 3-pole with auxiliary switch for switching status 1-pole+N with auxiliary switch for switching status 3-pole+N with auxiliary switch for switching status kg/Pc. Packaging 0,12 12 0,23 6 0,35 4 0,25 6 0,48 3 0,17 6 0,28 4 0,40 3 0,30 4 0,53 2 TYTAN® II - opto-electronic flashing indicators ref. page 12-13. Corresponding bus bar connectors can be found on page 72 Fool proof rated voltage coding The TYTAN® color coding system is designed for all amperages. It also caters to the new ranges of 13, 32 and 40A e.g.: 13A for 1,5mm2 e.g.: 32A for CEE-plugs e.g.: 40A for fault current switches 9 1.2 German Production & Technology TYTAN® II MAIN PROTECTION 35mm DIN rail unit D02 - Fuse switch disconnector with supervisory relay - integrated flashing indicator (OEFI) - safety switch - codeable for ALL amperages - sealable - lockable Technical data: Classification Norm Suitable for fuses Fire classification / Track resistance Protection / Voltage contact protection Rated operational voltage Ue -AC -DC Rated operational current Ie Over voltage category / degree of pollution Rated impulse withstand voltage Uimp Type of terminations Rated short circuit making capacity Icm Utilization category Fuse switch disconnector IEC 947-3 D01: 1, 2, 4, 6, 10, 13, 16; D02: 20, 25, 32, 35, 40, 50, 63AgL, gG, aM UL94 / V0, heating wire resistance 960°C / CTI 600 IP 20 / finger and back of hand proof 400V 1-pole 110V, 2-polig 220V 63A IV/3 (DIN VDE 0110) 6000V Stainless steel cage clamp 1,5...35mm2; MD4Nm, pozidriv 50kAeff AC 22B,DC 21B Item-No. 10 2751 10 2752 10 2753 10 2741 10 2743 10 2711 10 2712 10 2713 10 27XX 10 Component width a in mm 54 81 108 81 135 54 81 108 TYTAN® II MAIN PROTECTION D0–Fuse switch disconnector with fuse monitoring relay Fitted with TYTAN® II - opto electronic flashing plugs - potential free warning by fuse failure and switch position Item Item No. kg/Pc. Packaging 1-pole with fuse monitoring 60-230/400V AC 10 2751 10 2752 10 2753 10 2741 10 2743 10 2751 10 2752 10 2711 10 2712 10 2713 0,18 0,29 0,41 0,31 0,54 0,18 0,29 0,18 0,29 0,41 6 4 3 4 2 6 4 6 4 3 2-1-pole with fuse monitoring 60-230/400V AC 3-1-pole with fuse monitoring 60-230/400V AC 1-pole+N with fuse monitoring 60-230/400V AC (N pre-/post lagging phase) 3-pole+N with fuse monitoring 60-230/400V AC (N pre-/post lagging phase) 1-pole with fuse monitoring 60-110V DC 2-pole with fuse monitoring 60-220V DC 1-pole with fuse monitoring 24-60V AC/DC 2-pole with fuse monitoring 24-60V AC/DC 3-pole with fuse monitoring 24-60V AC/DC TYTAN® II - opto-electronic flashing indicators ref. page 12-13 Corresponding bus bar connectors can be found on page 72 K’ELECTRIC WE CONNECT TO PROTECT U RESET Main current Power suply 24V - 230V AC/DC Voltage control Auxilary switch TYTAN D0 1...63A Relay 1 Relay 2 11 1.3 German Production & Technology TYTAN® II-OPTO ELECTRONIC FLASHING PLUGS 35mm DIN rail unit D0-Fuse plugs with built-in opto electronic flashing indicator suitable for insertion in TYTAN® II - fuse switch disconnector and main protection switches. Fuses included K’ELECTRIC WE CONNECT TO PROTECT The inventive design of the plug ensures low loses Constant contact pressure Pressure spring 3 Dual contacts saves 0,8 watts per pole 4 Ceramic body 5 Quartz sand 6 Fuse element 7 Base contact 8 Sand sealing cover 1 2 1 2 3 3 4 5 6 3 7 3 12 8 TYTAN® II-FLASHING PLUGS for TYTAN® II - Fuse switch disconnectors and main protection switches 1 set = 3x plugs with fuses, 3x coding inserts, spares in clip box Item 1 Set 1A 1 Set 2A 1 Set 4A 1 Set 6A 1 Set 10A 1 Set 13A 1 Set 16A 1 Set 20A 1 Set 25A 1 Set 32A 1 Set 35A 1 Set 40A 1 Set 50A 1 Set 63A Colour orange pink brown green red ocher grey blue yellow purple 60 - 400V AC Item-No. 10 2601 10 2602 10 2604 10 2606 10 2610 10 2613 10 2616 10 2620 10 2625 10 2632 24 - 60V DC Item-No. 10 2401 10 2402 10 2404 10 2406 10 2410 10 2413 10 2416 10 2420 10 2425 10 2432 60 - 240V DC Part-No. 10 2501 10 2502 10 2504 10 2506 10 2510 10 2513 10 2516 10 2520 10 2525 10 2532 black violet white copper 10 2635 10 2640 10 2650 10 2663 10 2435 10 2440 10 2450 10 2463 10 2535 10 2540 10 2550 10 2563 kg/box Packaging 0,13 1/12 0,13 1/12 0,13 1/12 0,13 1/12 0,13 1/12 0,13 1/12 0,13 1/12 0,13 1/12 0,13 1/12 0,13 1/12 0,13 0,13 0,13 0,13 1/12 1/12 1/12 1/12 TYTAN® II ACCESSOIRES Short circuit plug cut off element 1 Set: 3 pcs. Item Item-No. Label: Warning triangle Label:“Trennmesser” 10 2300-2 10 2300-3 kg/box Packaging 0,20 0,20 1/12 1/12 Re-switch block in a clip box for DIN rails Item Padlock 5A5 Padlock 5A4 Padlock 5A3 Padlock 5A1 Padlock 5A2 Plastic lock Plastic lock Plastic lock Plastic lock Plastic lock Colour black blue green yellow red black blue green yellow red Item-No. 10 2007-1 10 2007-2 10 2007-3 10 2007-4 10 2007-5 10 2008-1 10 2008-2 10 2008-3 10 2008-4 10 2008-5 kg/box Packaging 0,09 1/12 0,09 1/12 0,09 1/12 0,09 1/12 0,09 1/12 0,06 1/12 0,06 1/12 0,06 1/12 0,06 1/12 0,06 1/12 13 1.4 German Production & Technology TYTAN® I 35mm DIN rail unit D01 - Fuse switch disconnector - integrated flashing indicator (OEFI) - universal-fuse plug - compatible LS-switch -sealable Technical data: Classification Norm Suitable for fuses Fire classification / Track resistance Protection / Voltage contact protection Switch disconnector fuse IEC 947-3 D01: 2, 4, 6, 10 und 16; gL, gG, aM UL94 / V0, heating wire resistance 960°C / CTI 600 IP 20 / finger and back of hand proof Rated operational voltage Ue -AC -DC Rated operational current Ie Over voltage category / degree of pollution Rated impulse withstand voltage Uimp 400V 1-pole 110V, 2-pole 220V 16A IV/3 (DIN VDE 0110) 6000V Stainless steel cage clamp 1,5...25mm2; MD 2,5Nm, pozidriv Type of terminations Rated short circuit making capacity Icm Utilization category 10 1651 10 1652 14 10 1653 50kAeff AC 22B 10 1641 10 1643 TYTAN® I D01-Switch disconnector fuse Flashing indicator This built-in opto electronic flashing indicator is activated when the fuse blows. The dependable disturbance indication replaces the unreliable mechanical indicator. This special feature leaves the vital protective insulation intact due to the elimination of the hole for the indicator. Item 1-pole 2-pole 3-pole 1-pole+N (N pre-/post lagging phase) 3-pole+N (N pre-/post lagging phase) Corresponding bus bar connectors can be found on page 72 Item-No. 10 1651 10 1652 10 1653 10 1641 10 1643 kg/box 0,09 0,18 0,27 0,17 0,35 Packaging 12 6 4 6 3 Fuse plug This innovative fuse plug protects the operator. A blown fuse with a temp. of up to 100°C can be replaced without direct physical contact K’ELECTRIC WE CONNECT TO PROTECT Automatic coding TYTAN® l codes the rated current of the fuse via a smart plug. This plug permits the coding of all current levels. The coding of the max. permissible rated current of the fuse is individually set by the technician by means of a adjustable coding insert. When the fuse is inserted in the plug, the coding insert is activated in dependence with the rated current 15 1.5 German Production & Technology TYTAN® T Switch disconnector fuse for D0- and cylindrical fuses 10x38mm - only 4TE wide - intgrated flashing indicator (OEFI) - universal-fuse plug Technical data: Classification Norm Suitable for D0- fuses DIN 49522 Suitable for cylindrical fuses IEC 60269-1 Fire classification / Track resistance Protection / Voltage contact protection Rated operational voltage Ue -D0 -10 x 38 Rated operational current Ie Over voltage category / degree of pollution Rated impulse withstand voltage Uimp Type of terminations Rated short circuit making capacity Icm Utilization category Thermo switch 16 35mm DIN rail unit Switch disconnector fuse IEC 947-3 D01: 2, 4, 6, 10, 16; D02: 20, 25, 32, 35, 40, 50, 63AgL, gG, aM 10 x 38mm: 2, 4, 6, 8, 10, 12, 16, 20, 25, 32A UL94 / V0, heating wire resistance 960°C / CTI 600 IP 20 / finger and back of hand proof 400V AC 500V AC D0: 63A; 10 x 38: 32A IV/3 (DIN VDE 0110) 6000V Stainless steel cage clamp 1,5...25mm2; MD 3,5Nm, Pozidriv 50kAeff AC 22B AC: 1,5A/250V; cos 0,6; DC 1,2A/48V TYTAN® T Switch disconnector fuse for D0 and cylindrical fuses Item Item-No. TYTAN® T, 400V~, D0: 2...63A, 10x38mm: 2...32A 3-pole 3-pole + N (pre-/post lagging phase) 3-pole with aux. switch 5A / 250V for switching status 10 4213 10 4215 10 4217 0,40 0,40 0,40 3 3 3 TYTAN® T, 400V~, with Thermo-indicator 3-pole 3-pole + N (pre-/post lagging phase) 3-pole with aux. switch 5A / 250V for switching status 10 4203 10 4205 10 4207 0,40 0,40 0,40 3 3 3 TYTAN® T, 500V~, 10x38mm: 2...25A 3-pole 3-pole + N (pre-/post lagging phase) 3-pole with aux. switch 5A / 250V for switching status 10 4383 10 4385 10 4387 0,40 0,40 0,40 3 3 3 10 1774 10 4664 10 1780 0,01 0,05 0,01 12 1 3 Plugs and reducer springs from DO2 to DO1 and for fuses 10x38 mm Padlock in the click box Short circuit plug as a disconnector Bus bar connectors can be found on page 71 kg/box Packaging K’ELECTRIC WE CONNECT TO PROTECT 17 1.6 German Production & Technology TYTAN® T MAIN SWITCH Switch disconnector fuse for D0 and cylindrical fuses 10x38 mm including signal relay for fuse and temperature monitoring - only 4TE wide - integrated flashing indicator (OEFI) - universal-fuse plug Technical data: Classification Norm Suitable for D0- fuses DIN 49522 Suitable for cylindrical fuses IEC 60269-1 Fire classification / Track resistance Protection / Voltage contact protection Rated operational voltage Ue -D0 -10 x 38 Rated operational current Ie Over voltage category / degree of pollution Rated impulse withstand voltage Uimp Type of terminations Rated short circuit making capacity Icm Utilization category 18 35mm DIN rail unit Switch disconnector fuse IEC 947-3 D01: 2, 4, 6, 10, 16; D02: 20, 25, 32, 35, 40, 50, 63AgL, gG, aM 10 x 38mm: 2, 4, 6, 8, 10, 12, 16, 20, 25, 32A UL94 / V0, heating wire resistance 960°C / CTI 600 IP 20 / finger and back of hand proof 400V AC 500V AC D0: 63A; 10 x 38: 32A IV/3 (DIN VDE 0110) 6000V Stainless steel cage clamp 1,5...35mm2; MD 4Nm, Pozidriv 50kAeff AC 22B TYTAN® T MAIN PROTECTION with temperature and fuse monitoring TYTAN® – Main protection signals fuse cut-offs and forwards them with an RJ connection cable to the externally fitted relay. At the same time a dangerous overheating of the fuse plug is displayed and logged. As an interface on the relay part, a contact is available on each potential-free changeover. Collective fault messages can be monitored by the serial connecting of up to 12 fuse plugs. K’ELECTRIC WE CONNECT TO PROTECT Item Item-No. kg/pc 10 4703 10 4705 0,50 0,50 3 3 10 4783 10 4785 0,50 0,50 3 3 use DIN rail 35x15mm! Main protection relay module HR 11; 3 switch contacts (reports ; blown fuse, excess temp., on/off ) 10 3711 Main protection relay module HR 12; 2 switch contact (reports; blown fuse, excess temp.) 10 3712 Main protection relay module HR 13; 1switch contact (reports; blown fuse, excess temp.) 10 3713 0,12 0,12 0,12 1 1 1 0,01 400V~, D0:2…63A; 10X38: 2…32A TYTAN TH1 3-pole TYTAN TH1 3-pole+N (pre-/post lagging phase) use DIN rail 35x15mm! 500V~, 10X38: 2…25A TYTAN TH1 3-pole TYTAN TH1 3-pole+N (pre-/post lagging phase) RJ-connection cable 200mm RJ-connection cable 500mm RJ-connection cable 1000mm further lengths at disposal Mains adapter 100-240V AC/24V DC 10W Mains adapter 100-240V AC/24V DC 30W Bus bar connectors can be found on page 71 Packaging 10 3730 10 3731 10 3732 0,01 0,01 1 1 1 10 3700 10 3701 0,10 0,25 1 1 Quick connection using RJ plugs Single evaluation Collective disturbance signal 19 1.7 German Production & Technology CORON® 2 D0-Fuse switch disconnector - integrated flashing indicator (OEFI) - universal-fuse plug - sealable - lockable with padlock Technical data: Classification Norm Suitable for fuses Fire classification / Track resistance Protection / Voltage contact protection Rated operational voltage Ue -AC -DC Rated operational current Ie Over voltage category / degree of pollution Rated impulse withstand voltage Uimp Type of terminations Rated short circuit making capacity Icm Utilization category 20 35mm DIN rail unit Fuse switch disconnector IEC 947-3 D01: 2, 4, 6, 10, 16; D02: 20, 25, 32, 35, 40, 50, 63AgL, gG, aM UL94 / V0, heating wire resistance 960°C / CTI 600 IP 20 / finger and back of hand proof 400V 1-pole 110V, 2-polig 220V 63A IV/3 (DIN VDE 0110) 6000V Stainless steel cage clamp 1,5...35mm2; MD 4Nm, pozidriv 50kAeff AC 22B CORON® 2 D0-Fuse switch disconnector CORON® 2 Item Item-No. 1-pole 1-pole + N (pre-/post lagging phase) 2-pole 3-pole 3-pole + N (pre-/post lagging phase) Plug-reducer spring from D02 to D01 Padlock in the click box 10 4651 10 4641 10 4652 10 4653 10 4643 10 4601 10 4664 kg/pc 0,13 0,26 0,26 0,40 0,53 0,01 0,05 Packaging 12 6 6 4 3 12 1 Bus bar connectors can be found on page 72 K’ELECTRIC WE CONNECT TO PROTECT 21 1.8 D0-FUSE BASE E18 - touch-protected version - easy inscription possible German Production & Technology DIN SchienenGeräte H 35mm Technical data: 1 – 3-pole; DIN 49524 for D0-fuses 2…63A 400V AC/250V DC With snap on or screw on mounting Terminations: Stainless steel cage clamp 1,5-35mm Item Item-No. Packaging 1-pole 3-pole 10 4011 10 4013 20 6 Bus bar connectors see page 72 Screw caps ref. page 64 22 2.0 BUS BAR SYSTEM 60mm K’ELECTRIC WE CONNECT TO PROTECT “ SYSTEM 60” is a modular designed current distribution system up to 630A Snap on mounting of all components provides extreme flexibility in assembly and add on design. 23 BUS BAR SYSTEM 60 mm 24 2.1 Bus bar support 2.2 Input clamps - rotating base - an extensive bus bar programm can be realised with few components - for bus bars 12-30mm/5 and 10mm - also fits Striebel & John cabinets The input of the system 60 takes place via the connecting terminals - Protective covers and a universal connection clamp individually according to the cross section of the connection 2.5 TYTAN® R 2.6 TYTAN® R Hauptschutz D02 - Bus mounting switch disconnector - flashing indicator - safety switch - width 27mm - lockable D02 - Bus mounting switch disconnector with fuse and temperature control - flashing indicator - safety switch - width 36mm - lockable 2.9 NH-Bus bar mounting fuse load break switch Modell series KE 2.10 NH-vertical fuse switch disconnector MULTIVERT® NH 00 MSL 2.3 D0 - Bus mounting fuse base E18 - distinctive labeling on the base. - low loss stainless steel terminal clamps - contact protection shroud on the sides - clip on rear touch protection shroud 2.7 CORON® R D02 - Bus mounting switch disconnector - flashing indicator - safety switch - width 27mm - lockable - compact and low form 2.4 Component adapter - steplessly adjustable - mounting support - low loss dual contact 2.8 NH- Bus bar mounting fuse load break switch Modell series MULTIBLOC® 2.11 Partitions and shrouds The partition and shroud system offers comprehensive contact protection for the System 60 25 2.1 System 60 BUS BAR SUPPORT - rotating base - an extensive bus bar programm can be realised with very few components - for bus bars 12-30mm/5 and 10mm - also fits Striebel & John cabinets 26 ACCESORIES FOR SYSTEM 60 Item No. 10 6300 10 6301 10 6302 10 6304 10 6307 10 6303 10 6308 10 6310 10 6311 kg/pc 0,121 0,006 0,048 0,056 0,004 0,019 0,024 0,006 0,007 Bus bar support 2-pole; 1 fixing hole Bus bar support 2-pole; 2 fixing holes 10 6004 10 6005 0,08 0,09 Packaging 10 20 10 10 10 10 10 10 10 10 10 Measured peak current lpk in KA Item 3-pole, 2-hole mounting inside; incl. spacer and fixing screws External fixing with item 10 6300 incl. fixing screws 1-pole, fixed to 10 6300 or for 2-pole; incl. spacer and fixing screws 1-pole, for single assembly; incl. spacer and fixing screws Combi joiner; for the assembly of a 2-pole bus bar with 2 X 10 6203 End cap 3-pole; yellow with warning triangle Z-end cap 3-pole; yellow with warning triangle End cap 1-pole Z-end cap 1-pole Bus bar support gap in mm Resistance to short-circuits chart after IEC 60439-1: 1999-09; DIN EN 60439 part 1 (VDE 0660 part 500): 2000-08 bus bar system 60mm calculation operating voltage: 690V rated frequency: 50Hz 10 6303 end cap 3-pole 10 6308 Z-end cap 3-pole also as side protection for the bus mounting fuse base 10 6309 fixing-screw 25mm 10 6300 bus bar support 3-pole 2-hole assemby inside 10 6312 fixing screw 10mm 10 6301 external fitting for 4- hole assembly 10 6310 endcap 1-pole 10 6311 Z-endcap 1-pole 10 6309 fixing screw 25mm 10 6302 bus bar support 1-pole fixable for extending a 4- or 5-pole bus bar 10 6307 combi joiner for the assembly of a 2-pole bus base 10 6310 end cap 1-pole 10 6311 Z-end cap 1-pole 10 6309 fixing screw 25mm 2 x 10 6302 bus bar support 2-pole 2-hole assembly 27 2.2 German Production & Technology INPUT CLAMPS The input connections of the System 60 are carried out using a universal connection clamp that matches with the cross section of the conductor Clip on protective covers provide for required safety System 60 K’ELECTRIC WE CONNECT TO PROTECT 28 Connection clamps and protection covers with warning triangle including conductor and bus bar protection cover Item (yellow) Item-No. 10 6090 10 6091 10 6092 kg/pc. 0,11 0,17 0,22 Packaging 2 1 1 Item-No. 10 6096 10 6097 10 6098 kg/pc. 0,11 0,17 0,22 Packaging 2 1 1 Item Item-No. kg/pc. Packaging 54mm wide, internal height 44mm2 10 6033 10 6034 10 6035 0,09 0,12 0,12 2 1 1 Item Item-No. kg/pc. Packaging 1,5…16mm2, for 5mm2 bus bars 1,5…35mm2, for 5mm2 bus bars 1,5…50mm2, for 5mm2 bus bars 16…70mm2, for 5mm2 bus bars 16…120mm2, for 5mm2 bus bars 16…185mm2, for 5mm2 bus bars 1,5…16mm2, for 10mm2 bus bars 1,5…35mm2, for 10mm2 bus bars 1,5…50mm2, for 10mm2 bus bars 16…70mm2, for 10mm2 bus bars 16…120mm2, for 10mm2 bus bars 16…185mm2, for 10mm2 bus bars 11 6051 11 6052 11 6053 0,03 0,04 0,05 100 50 50 11 6054 11 6055 11 6056 11 6061 11 6062 11 6063 11 6064 11 6065 11 6066 0,06 0,09 0,10 0,03 0,04 0,05 0,06 0,09 0,10 10 10 10 100 50 50 10 10 10 Item Item-No. kg/pc. Packaging 1,5…16mm2, for 5mm2 bus bars 4,0…35mm2, for 5mm2 bus bars 16…70mm2, for 5mm2 bus bars 16…120mm2, for 5mm2 bus bars 16…185mm2, for 5mm2 bus bars 1,5…16mm2, for 10mm2 bus bars 4,0…35mm2, for 10mm2 bus bars 16…70mm2, for 10mm2 bus bars 16…120mm2, for 10mm2 bus bars 16…185mm2, for 10mm2 bus bars 11 6070 11 6071 11 6072 11 6073 11 6074 11 6080 11 6081 11 6082 11 6083 11 6084 0,03 0,04 0,06 0,09 0,10 0,03 0,04 0,06 0,09 0,10 50 50 10 10 10 50 50 10 10 10 54mm wide, internal height 44mm, for clamps 16…50mm2 108mm wide, internal height 44mm, for clamps 16…70mm2 108mm wide, internal height 80mm, for clamps 16…185mm2 Item (grey) 16…50mm2 54mm wide, internal height 44mm, for clamps 108mm wide, internal height 44mm, for clamps 16…70mm2 108mm wide, internal height 80mm, for clamps 16…185mm2 Bus bar protection cover, grey 108mm wide, internal height 44mm2 108mm wide, internal height 80mm2 ZUBEHÖR SYSTEM 60 ACCESSORIES FOR SYSTEM 60 Pressure clamps Pressure clamps for AI und Cu 29 2.3 German Production & Technology labeling space D0 - BUS MOUNTING FUSE BASE E18 System 60 - distinctive labeling on the base. - low loss stainless steel terminal clamps - contact protection shroud on the sides - clip on rear touch protection shroud Technical Data 3-pole; DIN VDE 0636-3 for D0-fuse links 2…63A DIN49522 Cartridge ring adapter D02 DIN 49523 400V AC/250V DC 50KAeff Steel cage clamp 1,5...25mm2, 3-4Nm Creep resistance: CTI600, Fire classification: UL94-V0 Temperature withstand: 200C, Glow wire: 960°C Artikel Bus mounting fuse base 27mm, without cover Bus mounting fuse base 27mm, with cover Bus mounting fuse base 36mm, with cover and lateral extension Bus mounting fuse base 54mm, with cover and lateral extension Cover shroud 27mm Cover shroud 36mm, incl. extension Cover shroud 54mm, incl. extension Shroud pair Single left Single right Clip on touch protection shroud with back of hand protection Artikel-Nr. kg/Stück VE €/Stk. 10 6022 10 6023 10 6028 10 6029 10 6011 10 6012 10 6013 10 6016 10 6017 10 6018 10 6026 0,15 0,17 0,19 0,21 0,02 0,03 0,05 0,05 0,02 0,02 0,01 10 10 10 10 10 10 10 10 10 10 10 5,60 6,25 6,60 7,40 0,70 1,00 1,80 2,70 0,85 0,85 1,80 Fuses and screw caps ref. page 62 Frame covering for the switch board 10 6022 30 10 6011 10 6012 10 6013 10 6017 10 6018 10 6016 (pair) 10 6016 (pair) for masking the middle of bus bar supports or for use on left or right frames at the beginning or end of a bus base 2.4 COMPONENT ADAPTER - steplessly adjustable - mounting support - low loss dual contact Item Item-No. kg/pc. Packaging 10 6142.451 10 6142.452 10 6142.541 10 6142.542 0,21 0,23 0,22 0,24 2 2 2 2 1 universal mounting rail, 63mm wide 1 universal mounting rail, 72mm wide 2 universal mounting rails, 81mm wide 10 6143.451 10 6143.452 10 6143.541 10 6143.542 10 6143.631 10 6143.721 10 6143.812 0,22 0,24 0,23 0,25 0,27 0,29 0,31 2 2 2 2 2 2 2 Ie=63A connection cable cross section AWG 8 / 10mm2 1 universal mounting rail, 54mm wide 2 universal mounting rails, 54mm wide 1 universal mounting rail, 63mm wide 1 universal mounting rail, 72mm wide 2 universal mounting rails, 81mm wide 10 6146.541 10 6146.542 10 6146.631 10 6146.721 10 6146.812 0,26 0,28 0,30 0,32 0,34 2 2 2 2 2 Ie=80A connection cable cross section AWG 6 / 16mm2 1 universal mounting rail, 54mm wide 2 universal mounting rails, 54mm wide 1 universal mounting rail, 63mm wide 1 universal mounting rail, 72mm wide 2 universal mounting rails, 81mm wide 10 6148.541 10 6148.542 10 6148.631 10 6148.721 10 6148.812 0,29 0,31 0,33 0,35 0,37 2 2 2 2 2 Ie=25A connection cable cross section AWG 12 / 4mm2 1 universal mounting rail, 45mm wide 2 universal mounting rails, 45mm wide 1 universal mounting rail, 54mm wide 2 universal mounting rails, 54mm wide Ie=35A connection cable cross section AWG 10 / 6mm2 1 universal mounting rail, 45mm wide 2 universal mounting rails, 45mm wide 1 universal mounting rail, 54mm wide 2 universal mounting rails, 54mm wide 10 6142 10 6143 10 6146 10 6148 10 6152 10 6153 10 6140 10 6142 10 6143 10 6146 10 6148 10 6152 10 6153 10 6110 31 German Production & Technology COMPONENT ADAPTOR Item Ie = 25A; 4mm2 connection cable cross section, AWG 12 width 45mm Ie = 35A; 6mm2 connection cable cross section, AWG 10 width 45mm Is = 63A; 10mm2 connection cable cross section, AWG 8 width 45mm Ie = 80A; 16mm2 connection cable cross section, AWG 6 width 45mm Item-No. 10 6142 10 6143 10 6146 10 6148 kg/pc. 0,19 0,20 0,23 0,26 Packaging 4 4 4 4 Ie = 25A; Double central terminal 4mm2, AWG 12 width 45mm Ie = 35A;Double central terminal 4mm2, AWG 10 width 45mm Without contacts; incl. X connector for lateral extension or single mounting; 45mm 10 6152 10 6153 10 6140 0,20 0,25 0,15 4 4 4 Item-No. kg/pc. 10 6110 10 6104 10 6105 10 6106 10 6107 10 6108 0,02 0,02 0,02 0,02 0,02 0,02 Accessories Item Lateral extension piece for the adaptor in 9mm steps Universal mounting rail 45mm wide; steplessly adjustable Universal mounting rail 54mm wide; steplessly adjustable Universal mounting rail 63mm wide; steplessly adjustable Universal mounting rail 72mm wide; steplessly adjustable Universal mounting rail 81mm wide; steplessly adjustable Packaging 10 10 10 10 10 10 Mounting rails are steplessly adjustable with dual wedge fastening Adapter base Position the upper mounting rail and fasten from the front. + 9mm side part enables an individuell extension of the base in steps of 9mm 1. Place the component on the top mounting rail and connect 2. Place the component on the lower mounting rail. Position the lower mounting rail to suit component and then connect. + Mounting rail with dual wedge fastening 32 Fasten lower mounting rail from below Contacting 1 Dual contacting 2 Contact clamp 2 3 Spring loaded steel clamp 4 5mm spacer clip with CuAg contact 3 4 1 5mm 5 1 5 Bus bar The dual contacting design has low losses. Contact pressure exclusively via the metal clamp and not via plastic parts.. K’ELECTRIC WE CONNECT TO PROTECT COMPONENT ADAPTOR with TYTAN® D0-fuse switch disconnector ready for mounting on a 60mm bus bar adaptor incl. connections and protective shrouds centre to centre Design 100mm Item-No. 125mm Item-No. 150mm Item-No. kg/pc. Packaging TYTAN® I Mono TYTAN® I Mono TYTAN® I Duo TYTAN® I Duo TYTAN® I Duo 1X3-poles 3X1-poles 2X3-poles 6X1-poles 3X1+1X3 10 6201 10 6203 10 6202 10 6204 10 6205 10 6201 10 6203 10 6206 10 6207 10 6208 - 0,52 0,52 0,80 0,80 0,80 1 1 1 1 1 TYTAN® II Mono TYTAN® II Mono TYTAN® II Duo TYTAN® II Duo TYTAN® II Duo TYTAN® II Mono TYTAN® II Mono TYTAN® II Duo TYTAN® II Duo 1X3-poles 3X1-poles 2X3-poles 6X1-poles 3X1 + 1X3 1X2-poles 2X1-poles 2X2-poles 4X1-poles 10 6221 10 6223 10 6222 10 6224 10 6225 10 6239 10 6240 10 6237 10 6238 10 6221 10 6223 10 6226 10 6227 10 6228 10 6239 10 6240 10 6232 10 6233 10 6234 10 6235 10 6229 10 6230 10 6231 - 0,85 0,85 1,30 1,30 1,30 0,46 0,46 0,70 0,70 1 1 1 1 1 1 1 1 1 Item TYTAN® II Main Protection mounted on component adaptor Item TYTAN® II Mono TYTAN® II Duo TYTAN® II Mono TYTAN® II Duo Design 1X3-poles 2X3-poles 1X2-poles 2X2-poles 100mm Item-No. - 125mm Item-No. 150mm Item-No. kg/pc. Packaging. 10 6275 10 6276 10 6285 10 6289 106277 106278 - 1,30 1,75 0,70 0,98 1 1 1 1 33 2.5 German Production & Technology Flashing indicator Fuse failure can be reliably identified and reported through the opto-electronic flashing indicator. Quick and easy fuse swop The fuse holder enables an easy and safe swop of the D0-fuse plug. Operating status display Lock With the optical display unauthorized switching. A simple lock to prevent on / off the operating condition can be constantly TYTAN® R checked. D02 - Bus mounting switch disconnector - flashing indicator - safety switch - width 27mm - lockable System 60 multi pole 3-pole+N 34 3-pole single pole New! Fuse plug with power indicator can be fitted on standard equipment min/max value can be saved D02 - Bus mounting switch disconnector TYTAN® R Technische Daten Classification Norm Suitable for D0 fuses DIN 49522 Suitable for cylinder fuses IEC 60269-1 Fire classification / Track resistance Protection / Voltage contact protection Rated operational voltage Ue -D0 -10 x 38 Rated operational current Ie Over voltage category / degree of pollution Rated impulse withstand voltage Uimp Type of terminations Rated short circuit making capacity Icm Utilization category Bus bar measurements Item 400V~, D0:2…63A; 10x38: 2…32A400V~, Switch disconnector fuse IEC 947-3 D01: 2, 4, 6, 10, 16; D02: 20, 25, 32, 35, 40, 50, 63AgL, gG, aM 10 x 38mm: 2, 4, 6, 8, 10, 12, 16, 20, 25, 32A UL94 / V0, heating wire resistance 960°C / CTI 600 IP 20 / finger and back of hand proof 400V AC 500V AC D0: 63A; 10 x 38: 32A IV/3 (DIN VDE 0110) 6000V Stainless steel cage clamp 1,5...25mm2; MD 3,5Nm, Pozidriv 50kAeff AC 22B 12mm - 30mm; 5 und 10mm depth Item-No. kg/pc. Packaging 3-pole 3-pole+N 3-pole; with auxiliary switch for switch position 3-polig+N; with auxiliary switch for switch position 10 6601 10 6602 10 6603 10 6604 0,40 0,40 0,40 0,40 3 3 3 3 500V~, 10x38: 2…25A 3-pole 3-pole+N 3-pole; with auxiliary switch for switch status 3-pole+N; with auxiliary switch for switch status 10 6631 10 6632 10 6633 10 6634 0,40 0,40 0,40 0,40 3 3 3 3 10 6626 10 1774 10 4664 10 1780 10 6675 0,01 0,01 0,05 0,01 0,05 10 12 1 3 1 Rear touch protection; plugin above and below Plug reduction spring from D02 to D01 Padlock in the click box Short circuit plug as a disconnector Power measuring plug (Set = 3 pieces) 35 2.6 German Production & Technology MAIN PROTECTION - intelligent fuse monitoring TYTAN® R MAIN PROTECTION D02 - Bus mounting switch disconnector with fuse and temperature control - flashing indicator - safety switch - width 36mm - lockable System 60 TYTAN® R Main protection with temperature and fuse monitoring kg/pc. 10 6701 10 6702 0,40 0,40 3 3 10 6731 10 6732 0,40 0,40 3 3 Mains protection – relay module HR11; 3 switch contacts (reports: blown fuse, excess temperature, on/off) 10 3711 10 3712 Mains protection – relay module HR12; 2 switch contacts (reports: blown fuse, excess temperature) 10 3713 Mains protection – relay module HR13; 1 switch contact (reports: blown fuse, excess temperature) 0,12 0,12 0,12 1 1 1 10 3730 10 3731 10 3732 0,01 0,01 0,01 1 1 1 10 3700 10 3701 0,10 0,25 1 1 500V~, 10x38: 2…25A TYTAN RH1 3-pole TYTAN RH1 3-pole+N (pre-/post lagging phase) 36 Packaging Item-No. Item 400V~, D0:2…63A; 10x38: 2…32A TYTAN RH1 3-pole TYTAN RH1 3-pole+N (pre-/post lagging phase) RJ-connection cable 200mm RJ-connection cable 500mm RJ-connection cable 1000mm Further lengths on request Power Supply 100-240V AC/24V DC 10W Power Supply 100-240V AC/24V DC 30W TYTAN® – Main protection switch indicates fuse breaks and has the capability of transmitting a floating signal via an RJ-connection cable on the external relay. A dangerous overheating of the fuse switch can be reliably identified and reported. The serial interface on each relay has a floating signal via a relay contact For collective disturbance monitoring it is possible to put 12 fuse switches together. Relay supply : 24V DC Relay exit: 1 Switch contact for fuse failure 1 Switch contact for temperature control 1 Switch contact for Switch position 3x green normal operating condition middle red fuse break bottom yellow overheating K’ELECTRIC WE CONNECT TO PROTECT 37 2.7 CORON® R D02 - Bus mounting switch disconnector - flashing indicator - safety switch - width 27mm - lockable - compact and low form D02 - Bus mounting switch disconnector CORON®R Technical data Classification Norm Suitable for D0 fuses DIN 49522 Fire classification / Track resistance Protection / Voltage contact protection Rated operational voltage Ue Rated operational current Ie Over voltage category / degree of pollution Rated impulse withstand voltage Uimp Type of terminations Rated short circuit making capacity Icm Utilization category Bus bar dimensions 38 Switch disconnector fuse IEC 947-3 D01: 2, 4, 6, 10, 16; D02: 20, 25, 32, 35, 40, 50, 63AgL, gG, aM UL94 / V0, heating wire resistance 960°C / CTI 600 IP 20 / finger and back of hand proof 400V AC D0: 63A; 10 x 38: 32A IV/3 (DIN VDE 0110) 6000V Stainless steel cage clamp 1,5...25mm2; MD 3,5Nm, Pozidriv 50kAeff AC 22B 12mm - 30mm; 5 und 10mm thick German Production & Technology - compact and low construction form - with a 4-pole collective rail system leading connection clips can be placed on the N rail - sealable and lockable optional extension set K’ELECTRIC WE CONNECT TO PROTECT CORON® R Item 400V~, D0:2…63A 3-pole extension set Item-No. kg/pc. Packaging 10 6901 10 6971 0,40 0,01 4 1 Plug reduction spring from D02 to D01 Padlock in the click box 10 1774 10 4664 0,01 0,05 12 1 Schematic diagram Multi pole 39 German Production & Technology 2.8 NH-Bus bar mounting fuse load break switch series MULTIBLOC® series Size 000 3-pole 100A / 690 54mm width Item NH 000 RT, clamp strap 2,5-50mm 2,5-50mm2, output at bottom end NH 000 RT, clamp strap 2,5-50mm 2,5-50mm2, output at top end Control switch indicating switching status Bus bar touch protection 1 set = 2 Pcs. Protection material ref. page 62 System 60 - snap on assembly - for bus bars 12-30mm wide and 5-10mm thickness - integrated touch protection Item-No. kg/pc. Packaging 14 9010 14 9011 14 0643 14 0644 0,60 0,60 1 1 1 1 Cabel covering (Accessory) 40 Technical details ref. page 43 NH-Bus bar mounting fuse load break switch series MULTIBLOC® series Size 00 3-pole 160A / 690V - snap on assembly - selectable upper or lower cable outputs - for bus bars 12-30mm wide and 5-10mm thickness - fuse surveillance - optional Item Item-No. kg/pc. Packaging NH-00 RT, 3 M8 terminal screws, 3 clamp straps 4-70mm2 NH-00 RT, 3 M8 terminal screws, 3 clamp straps 4-70mm2 with elec. fuse surveillance (monitoring) 14 8010 14 8070 0,88 0,96 1 1 Monitoring switch for switching status Cable termination protection cover 1 set = 2 pcs. Bus bar touch protection 1 set = 2 pcs. 14 0852 14 0147 14 0148 14 0155 14 0126 14 0127 14 0128 0,01 0,05 1 1 0,05 0,01 0,02 0,05 0,07 1 1 1 1 1 Covering for distributor installation, single double triple Protection material ref. page 62 Technical details ref. page 43 K’ELECTRIC WE CONNECT TO PROTECT 41 NH-Bus bar mounting fuse load break switch MULTIBLOC® NH 1 RT System 60 Size 1 3-pole 250A / 690V IItem Item-No. kg/pc. Packaging NH 1 RT with 3 terminal screws M 10 NH 1 RT with 3 terminal screws M 10, with electronic fuse monitoring 14 8110 14 8170 3,06 3,14 1 1 3 Clamp straps 70-150mm2 Monitoring switch for switching status Bus bar touch protection 1 set = 2 pcs. Cable termination protection cover 1 set = 2 pcs. 14 0420 14 0852 14 0355 14 0382 0,01 0,01 0,16 0,25 1 1 1 1 Covering for distributor installation, single 14 0353 0,07 1 K’ELECTRIC WE CONNECT TO PROTECT NH-Bus bar mounting fuse load break switch MULTIBLOC® NH 2 RT Size 2 3-pole 400A / 690V 42 Item Item-No. kg/pc. Packaging NH 2 RT with 3 terminal screws M10 NH 2 RT with 3 terminal screws M10, with electronic fuse monitoring 14 8210 14 8270 4,50 4,58 1 1 3 Clamp straps 120-240mm2 (set) Monitoring switch for switching status Bus bar touch protection 1 Set = 2 pcs. Cable termination protection cover 1 set = 2 pcs. Protection material ref. page 62 14 1237 14 0852 14 0862 14 0861 0,25 0,01 0,15 0,22 1 1 1 1 MULTIBLOC® NH 00 RT Cross section of main cover MULTIBLOC® NH 00 RT, 3-pole MULTIBLOC® NH 1 RT 5mm with spacer Cross section of main cover MULTIBLOC® NH 1 RT, 3-pole bus bar version MULTIBLOC® NH 2 RT 5mm with spacer Cross section of main cover MULTIBLOC® NH 2 RT, 3-pole NH 000 RT 3 100A 690 V 1000 V Technical data No. of poles Conventional free air thermal current links NH Ith Rated operational voltage Ue Rated insulation voltage Ui Rated impulse withstand voltage Uimp Conditional short circuit making capacity NH AC 400V AC 500V AC 690 V Utilizationcategory AC 23B AC 22B AC 21B NH 00 RT/AT 3 160A 690 V 1000 V NH 1 RT/AT 3 250A 690 V 1000 V NH 2 RT/AT 3 400A 690 V 1000 V NH 3 AT 3 630A 690 V 1000 V 6 KV 8 KV 12 KV 12 KV 12 KV 80kA 80kA 80kA 50kA 50kA 50kA 80kA 80kA 50kA 80kA 80kA 80kA 50kA 50kA 50kA 100A 100A 100A 160A 160A 125A 160A - 250A 250A 200A 250A 400A 400A 315A 400A 630A 630A 500A - IP 3X 7,5W IP 20 12W -5 bis + 40 IP 20 23W IP 20 34W IP 20 48W Rated operationalcurrent Ie voltage 400V 500V 690V Ie= Ie = Ie = 440V Ie= DC 22B 440V Ie= DC 21B Environment temperature tolerence °C Degree of protection max. permissible power dissipation of solid links Pn 43 2.9 NH-Bus bar mounting fuse load break switch Series KE Size 00 3-pole 160A / 690V Item System 60 - snap on assembly on 60mm bus bars - for 12-30mm width and 5-10mm thickness - integrated touch protection - lockable - fuse surveillance optional Item-No. 2,5-70mm2 Clamp strap output at bottom end Clamp strap 2,5-70mm2 output at top end Terminal screw M8 output at bottom end Terminal screw M8 output at top end Attachable connection space extension Monitoring switch for switching status kg/pc. Packaging 20 8010 20 8011 20 8012 0,90 0,90 0,90 1 1 1 20 8013 20 0148 20 0852 0,90 0,02 0,01 1 1 1 kg/pc. Packaging Size 1 3-pole 250A / 690V Item Item-No. Terminal screw M10 output at bottom end Terminal screw M10 output at top end Clamp straps 70-150mm2 (Set) Attachable connection space extension Monitoring switch for switching status 20 8110 20 8111 20 0420 20 1148 20 1852 2,50 2,50 0,01 0,02 0,01 1 1 1 1 1 115,00 115,00 16,50 3,80 4,95 Size 2 3-pole 400A / 690V Artikel 44 Terminal screw M10 output at bottom end Terminal screw M10 output at top end Clamp straps 120-240mm2 (Set) Attachable connection space extension Monitoring switch for switching status Protection material ref. page 62 Artikel-Nr. 20 8210 20 8211 14 1237 20 2148 20 1852 kg/Stück 4,50 4,50 0,25 0,02 0,01 VE €/Stk. 1 1 1 1 1 139,00 139,00 25,20 4,80 4,95 Size 00 3-pole 160A / 690V Size 1 3-pole 250A / 690V Size 2 3-pole 400A / 690V Technical data No. of poles Conventional free air thermal current links NH Ith Rated operational voltage Ue Rated insulation voltage Ui Rated impulse withstand voltage Uimp Utilization category Rated operational current Ie (A) Rated operational voltage Ue (A) Conventional nominal impactshort circuit current Rated short circuit making capacity Reduction by Ith (without Fuse operation) Rated operational frequency Degree of protection Environment temperature tolerence °C 690V 400V 690V 400V NH 00 3 160A 690 V 1000 V NH 1 3 250A 690 V 1000 V 3 400A 690 V 1000 V 8 KV 12 KV 12 KV AC 23B AC 22B DC 22B 250 250 250 400 690 250 80kA 25kA 100kA 80kA 25kA 100kA 32W AC 23B DC 21B DC 22B 400 400 400 690 440 220 80kA 15kA 20kA 100kA 80kA 15kA 20kA 100kA 45W 50-60 IP 20 AC 23B DC 21B DC 22B 160 160 160 690 440 250 20kA 80kA 100kA 20kA 80kA 100kA 12W 50-60 IP 20 50-60 NH 2 - IP 20 -25°C bis + 55°C 45 2.10 NH-vertical fuse switch disconnector MULTIVERT® NH 00 MSL Size 00 3-pole 160A / 690V - for snap on mounting on 60mm bus bar systems - Optional top/bottom cable terminal connections - for bus bars 20-30mm wide, 10mm thick System 60 NH 00 MSL Technical data 3 No. of poles 160A Conventional free air thermal current links NH Ith 690 V AC Rated operational voltage Ue 1000 V Rated insulation voltage Ui Rated impulse withstand voltage Uimp Conditional short circuit making capacity NH AC 400V AC 500V AC 690 V Utilizationcategory 8 KV 80kA 80kA 50kA Rated operationalcurrent Ie voltage 400V Ie= AC 23B 500V Ie = AC 22B 690V Ie = AC 21B Degree of protection max. permissible power dissipation of NH Fuses 160A 160A 100A IP 30 12W MULTIVERT® 160 A/60 mm for snap on mounting Item NH 00 MSL with 3 connection screws M8, incl. cover shroud 46 3 clamp straps Cu 4-70mm2 (set) Indicating switch for switching status Protection material ref. page 62 Item-No. 14 8050 kg/pc. 1,12 Packaging 1 14 8051 14 0852 0,04 0,01 1 1 2.11 PARTITIONS AND SHROUDS The partition and shroud system offers comprehensive contact protection for the System 60 System 60 Covering systems Item Item-No. kg/pc. Packaging Cover shroud for bus bar support 10 6300 Side cover for partition and shroud system Slitted shroud ; 2000mm long Closed shroud; 2000mm long Panel mount; support edge 32mm Panel cover 1000mm long 12 6070 12 6071 12 6072 12 6073 12 6074 12 6075 0,06 0,03 0,47 0,53 0,04 0,64 10 10 5 5 10 2 Item Item-No. kg/pc. Cover strips for 5mm bus bar Cover strips for 10mm bus bar 15 6076 15 6077 0,07 0,09 K’ELECTRIC WE CONNECT TO PROTECT Bus bar covering Length 1m for Cu-bars up to 30mm Packaging 10 10 47 3.0 NH-FUSE SWITCH DISCONNECTOR for panel mounting 3.1 Series MULTIBLOC® MULTIBLOC® NH 00 AT Size 00, 160A / 690V Panel mounting version 1-pole 2-pole 3-pole 3-pole + N K’ELECTRIC WE CONNECT TO PROTECT NH-fuse load break switch MULTIBLOC® NH 1 AT Size 1, 250A / 690V Panel mounting version 1-pole 2-pole 3-pole 3-pole + N 48 MULTIBLOC® NH 00 AT Size 00, 160A / 690V, 1-pole, 2-pole Artikel Item Artikel-Nr. Item-No. kg/Stück kg/pc. VE Packaging €/Stk. NH 00AT 1-pole with 6 clamp straps NH 00AT 2-pole with 6 clamp straps 4-70mm2 14 3019 14 3018 0,32 0,62 1 1 Cable termination cover 1 Set = 2 Stück Fixing set for DIN-bus bar 125mm Fixing set for DIN-bus bar 150mm Sealing set Monitoring switch for switching status Connection screws M8 (Set = 3 Stück) Connection clamps AI/Cu 1,5-70mm2 14 0149 14 0151 14 0152 14 0155 14 0852 14 8052 14 8053 0,02 0,08 0,10 0,01 0,01 0,03 0,04 1 1 1 1 1 1 1 4-70mm2 Size 00, 160A / 690V, 3-pole, panel mounting version Artikel Item Artikel-Nr. Item-No. kg/Stück kg/pc. 4-70mm2 NH 00AT with 6 clamp straps NH 00AT with 6 clamp straps 4-70mm2 with electronic fuse monitoring 14 3010 14 3070 0,74 0,82 1 1 Monitoring switch for switching status 14 0852 14 0148 14 0153 14 0154 0,01 0,05 0,14 0,16 1 1 1 1 14 0126 14 0127 14 0128 0,02 0,05 0,07 1 1 1 Item Item-No. kg/pc. NH 00 AT with connection screw 14 3090 1,8 Artikel-Nr. Item-No. kg/Stück kg/pc. Cable termination cover 1 set = 2 pcs. DIN - fixing for 125mm DIN - fixing for 150mm Covering for distributor installation, single double triple VE Packaging. €/Stk. Size 00, 160A / 690V, 3-polig+N Packaging 1 NH-Fuse load break switch MULTIBLOC® NH 1 AT Size 1, 250A / 690V, 1-pole, 2-pole Artikel Item VE Packaging €/Stk. NH 1AT 1-pole with terminal screws M10 NH 1AT 2-pole with terminal screws M10 14 3119 14 3118 1,02 2,06 1 1 Cable termination cover 1 Set = 2 pcs Fixing set for DIN-bus bar 125mm Fixing set for DIN-bus bar 150mm Sealing set Monitoring switch for switching status 14 0354 14 0402 14 0403 14 0155 14 0852 0,09 0,28 0,24 0,01 0,01 1 1 1 1 1 Item-No. kg/pc. 14 3110 14 3170 2,42 2,50 1 1 14 0420 14 0852 14 0382 14 0353 0,10 0,01 0,25 0,07 1 1 1 1 Item Item-No. kg/pc. NH 1 AT with terminal screws M10 14 3190 3,55 Size 1, 250A / 690V, 3-pole, panel mounting version Item NH 1 AT with 6 terminal screws M10 NH 1 AT with 6 terminal screws M10, with electronic fuse monitoring 3 Clamp straps 70-150mm2 Monitoring switch for switching status Cable termination cover 1 set = 2 pcs. Covering for distributor installation, single Packaging Size 1, 250A / 690V 3-pole+N Packaging Protection material ref. page 62 1 49 NH-Fuse load break switch MULTIBLOC® NH 2 AT Size 2, 3-polig, 400A / 690V Panel mounting version Packaging Item Item-No. kg/pc. NH 2 AT; with 6 terminal screws M10 NH 2 AT; with 6 terminal screws M10, 14 3210 14 3270 3,50 4,58 1 1 14 1237 14 0852 14 0861 0,25 0,01 0,22 1 1 1 kg/pc. with electronic fuse monitoring 3 clamp straps 120-240mm2 (set) Monitoring switch for switching status Cable termination cover 1 set = 2 pcs. NH-Fuse load break switch MULTIBLOC® NH 3 AT Size 3, 3-polig, 630A / 690V Panel mounting version Item-No. 14 3310 14 3370 4,94 5,23 1 1 3 clamp straps 150-300mm2 (set) Monitoring switch for switching status Cable termination cover 1 set = 2 pcs. 14 1238 14 0852 14 0893 14 0490 0,32 0,01 0,32 - 1 1 1 1 Bus bar-adapter system 60mm 50 Packaging Item NH 3 AT; with 6 terminal screws M12 NH 3 AT; with 6 terminal screws M12, with electronic fuse monitoring MULTIBLOC® NH 00 AT, 1-pole Dimensions of the control panel cutout for floor mounting, without cover max. controll panel thickness 4mm Dimensions for floor mounting switch panel neutral leader support attaching center connection center attaching center connection center Die neutral conductor support Art. Nr. 00SZNS can be mounted either on the left or on both sides MULTIBLOC® NH 00 AT NH-fuse load break switch 1-pole MULTIBLOC® NH 00 AT, 2-pole Dimensions of the control panel cutout for floor mounting, without cover max. controll panel thickness 4mm switch panel connection center attaching center Dimensions for floor mounting attaching center connection center Die Neutralleiterstütze Art. Nr. 00SZNS kann sowohl links als auch beidseitig montiert werden MULTIBLOC® NH 00 AT NH-fuse load break switch 2-pole MULTIBLOC® NH 00 AT, 3-polig Dimensions of the control panel cutout for floor mounting, without cover switch panel Dimensions for floor mounting connection center connection center MULTIBLOC® NH 00 AT NH-fuse load break switch 3-pole mounting variant MULTIBLOC® NH 00 AT, 3-polig+N Dimensions of the control panel cutout for floor mounting, without cover max. controll panel thickness 4mm switch panel Dimensions for floor mounting neutral leader support connection center attaching center attaching center connection center The neutral leader support Art. Nr. 00SZNS can be mounted on the left oron both sides MULTIBLOC® NH 00 AT NH-fuse load break switch 3-pole + N mounting variant 51 German Production & Technology MULTIBLOC® NH 1 AT Cross section of main cover MULTIBLOC® NH 1 AT, 3-pole mounting variant with electronic fuse monitoring ESÜ MULTIBLOC® NH 2 AT Cross section of main cover MULTIBLOC® NH 2 AT, 3-pole mounting variant with electronic fuse monitoring ESÜ NH-Fuse load break switch MULTIBLOC® NH 3 AT switch panel attaching center connection center dimensions for floor mounting 52 MULTIBLOC® NH 3 AT, 3-pole mounting variant MULTIBLOC® NH 3 AT, 3-pole mounting variant with electronic fuse monitoring ESÜ Technical data No. of poles Conventional free air thermal current links NH Ith Rated operational voltage Ue Rated insulation voltage Ui Rated impulse withstand voltage Uimp Conditional short circuit making capacity NH AC 400V AC 500V AC 690 V UtilizationRated operationalcategory voltage current Ie AC 23B 400V AC 22B 500V AC 21B 690V DC 22B 440V DC 21B 440V Environment temperature tolerence °C Ie= Ie = Ie = Ie= Ie= Degree of protection max. permissible power dissipation of solid links Pn NH 000 RT 3 100A 690 V 1000 V 6 KV NH 00 RT/AT 3 160A 690 V 1000 V 8 KV NH 1 RT/AT 3 250A 690 V 1000 V 12 KV NH 2 RT/AT 3 400A 690 V 1000 V 12 KV NH 3 AT 80kA 80kA 80kA 50kA 50kA 50kA 80kA 80kA 50kA 80kA 80kA 80kA 50kA 50kA 50kA 100A 100A 100A 160A 160A 125A 160A - 250A 250A 200A 250A 400A 400A 315A 400A 630A 630A 500A - IP 3X 7,5W IP 20 12W -5 to + 40 IP 20 23W IP 20 34W IP 20 48W 3 630A 690 V 1000 V 12 KV K’ELECTRIC WE CONNECT TO PROTECT 53 3.2 NH-FUSE SWITCH DISCONNECTOR for panel mounting Series KE Size 00 3-pole 160A / 690V Item Item-No. kg/pc. Packaging NH 00 with 6 clamp straps 4-70mm NH 00 with 6 terminal screws M8 20 3010 20 3011 0,70 0,70 1 1 Attachment set for DIN rail 20 0153 0,01 1 Attachable terminal space-extension Monitoring switch for switching status 20 0148 20 0852 0,02 0,01 1 1 kg/pc. Packaging Size 1 3-pole 250A / 690V Item Item-No. NH 1 with terminal screws M10 20 3110 2,00 1 Clamp straps 70-150mm (set) Attachable terminal space-extension Monitoring switch for switching status 20 0420 20 1148 20 1852 0,01 0,02 0,01 1 1 1 kg/pc. Packaging Size 2 3-pole 400A / 690V 54 Item Item-No. NH 2 with terminal screws M10 20 3210 3,00 1 Clamp straps 120-240mm (set) Attachable terminal space-extension Monitoring switch for switching status 14 1237 20 2148 20 1852 0,25 0,02 0,01 1 1 1 German Production & Technology Size 00 3-pole 160A / 690V Size 1 3-pole 250A / 690V Size 2 3-pole 400A / 690V Technical data No. of poles Conventional free air thermal current links NH Ith Rated operational voltage Ue Rated insulation voltage Ui Rated impulse withstand voltage Uimp Utilization category Rated operational current Ie (A) Rated operational voltage Ue (A) conventional rated peak short-circuit current Rated short circuit switch capacity power dissipation Ith (without fuse) measurement frequency Degree of protection Environment temperature tolerence °C 690V 400V 690V 400V NH 00 3 160A 690 V 1000 V NH 1 3 250A 690 V 1000 V 3 400A 690 V 1000 V 8 KV 12 KV 12 KV AC 23B DC 21B DC 22B 160 160 690 690 440 250 20kA 80kA 100kA 20kA 80kA 100kA 12W 50-60 AC 23B DC 22B 250 250 690 250 80kA 25kA 100kA 80kA 25kA 100kA 32W IP 20 IP 20 -25°C bis + 55°C AC 23B DC 21B DC 22B 160 400 400 690 440 220 80kA 15kA 20kA 100kA 80kA 15kA 20kA 100kA 45W 50-60 IP 20 50-60 NH 2 - 55 4.0 BUS BAR SYSTEM 100/185mm 4.1 BUS BAR SUPPORT for 100 and 185mm systems - snap on bus bar support mounting - bus bar rail width of 30—120 mm (185mm system) - bus bar rail width of 30—60 mm (100mm system) - bus bar rail thickness: 10 mm Technical data rated operating voltage rated insulation voltage rated frequency flame behavior resistance to leakage current continuous operation temperature filament firmness 1000V AC 2000V AC 50Hz to UL 94 V40 CTI 600 150° 960° M6 DIN 912 (rail adjustment) M6 DIN 912 (rail adjustment) 2 Carrier mounting holes (socket head screw M8 starting torque 20Nm +0/-2Nm) 56 ((socket head screw M8 starting torque 20Nm +0/-2Nm) M6 DIN 912 (rail adjustment) Item Item-No. 100mm bus bar carrier 3 pole 185mm bus bar carrier 3 pole bus bar carrier 1 pole 100mm end covering 3 pole 185mm end covering 3 pole 18 8100 18 8101 18 8102 18 8103 18 8104 kg/pc. Packaging 0,36 0,54 0,20 0,07 0,12 1 1 1 1 1 4.2 German Production & Technology NH-vertical fuse switch disconnector MULTIVERT® NH 00 MSL Size 00 3-pole 160A / 690V Mounting on 100mm bus bar systems Mounting on 185mm bus bar systems with adapter top/bottom cable terminal Technical Data No. of poles Conventional free air thermal current links NH Ith Rated operational voltage Ue Rated insulation voltage Ui Rated impulse withstand voltage Uimp Conditional short circuit making capacity NH 8 KV 80kA 80kA 50kA AC 400V AC 500V AC 690 V Utilizationcategory NH 00 MSL 3 160A 690 V AC 1000 V Rated operationalcurrent Ie voltage 400V Ie= AC 23B 500V Ie = AC 22B 690V Ie = AC 21B Schutzart Degree of protection max. permissible power dissipation of solid links Pn 160A 160A 100A IP 30 12W 57 MULTIBLOC® NH 00 MSL mounting on 100mm bus bar system open switch cover 2451) deponie1801) cross section of central cover drilling for Supporting angle (accessory) 1) Dimensions refer to bus bar upper edge connection screw M8 strap/Al/Cu/clamp frame clamp n.... number or switch panels A 170 163 172 MULTIBLOC® NH 00 MSL mounting on 185mm bus bar system 58 Item Item-No. kg/pc. NH 00 MSL with clamp straps 4-70mm2 NH 00 MSL with V-connection NH 00 MSL with frame straps Cu 2,5-70mm2 Claw strap (set) for direkt assemby 14 8055 14 8056 14 8057 14 8063 14 8066 14 8067 14 8076 14 8077 14 8061 1,12 1,12 1,12 0,10 0,45 0,85 0,56 0,45 0,45 Single adapter for mounting on 185mm SS-System Twin adapter for mounting on 185mm SS-System Single adapter for mounting on 185mm / Claw strap Single adapter for mounting on 185mm / claw cramp cover shield, set=2 pieces Protection material ref. page 62 Packaging 1 1 1 1 1 1 1 1 1 4.3 NH-vertical fuse switch disconnector MULTIVERT® Size 1-3 250A - 630A - mounting on 185mm bus bar system - top and bottom cable terminal - drill free direct assembly with claw clamps - various connecting possibilities without shroud for cable termination shroud for top cable termination article number: 148062 (accessory) for terminal connections with cable lugs (bolt and insert nut) - on switch boards with central cover shroud for top cable termination article number: 148064 (accessory) for terminal connections with cable lugs for installation in distribution units with central cover (cover level 16 mm reduced) standarddesign: integrated shroud for bottom cable termination for terminal connections with cable lugs (bolt and insert nut) - on switch boards with central coverg for clamp terminal connections (V-terminal) for special "high" clamp terminal connections (double V-clamps) - on switch boards with central cover and in feeder pillars 59 MULTIBLOC® NH 1-3 MSL open switch cover 2451) middle distance (separation) deponie: (large protection size 3) bus bar upper edge central cover 1) Dimensions refer to bus bar upper edge Technical Data according to EN/IEC 60947 Size Number of poles/phases Conventional free air thermal current with NH-fuse links Ith Rated operational voltage Ue Rated insulation voltage Ui Rated impulse withstand voltage Uimp Rated short circuit making capacity with fuse links NH AC 400V AC 500V AC 690 V Utilization category to IEC/EN60947-3 Ue= 400V AC Ue= 500V AC Ue= 690V AC Rated frequency Power dissipation by lth without NH-fuse links Power dissipation by lth without separation blade Degree of protection Max. power dissipation of fuse links Pn 60 NH 1 MSL 1 3 250A 690 V AC 1000 V 8 KV NH 2MSL 2 3 400A 690 V AC 1000 V 8 KV NH 3 MSL 3 3 630A 690 V AC 1000 V 8 KV 120kA 120kA 120kA 120kA 120kA 110kA 80kA 80kA 80kA AC 23 B AC 23 B AC 22 B 50-60 Hz 24W 65W IP 30 23W AC 23 B AC 22 B AC 21 B AC 23 B AC 22 B AC 21 B 50-60 Hz 92W 161W IP 30 43W 50-60 Hz 46W 126W IP 30 34W MULTIVERT® NH 1 MSL Size 1, 250A / 690V Item 1-pole switchable NH 1 MSL bolt connection M 10 NH 1 MSL press-in nut M 10 Item 3-pole switchable NH 1 MSL bolt connection M 10 NH 1 MSL V-connection with 3 V-clamps NH 1 MSL press-in nut M 10 Item-No. 14 8160 14 8162 kg/pc. 4,52 4,46 Packaging 1 1 Item-No. 14 8150 14 8190 14 8152 kg/pc. 4,67 4,60 4,63 Packaging 1 1 1 Item-No. 14 8260 14 8262 14 8268 kg/pc. 4,60 4,52 4,46 Packaging 1 1 1 Item-No. 14 8250 14 8290 14 8252 14 8258 kg/pc. 4,76 4,70 4,68 4,53 Packaging 1 1 1 1 Item-No. 14 8360 14 8362 14 8368 kg/pc. 5,43 4,38 6,10 Packaging 1 1 1 Item-No. 14 8350 14 8390 14 8352 14 8358 kg/pc. 5,59 5,52 5,63 4,53 Packaging 1 1 1 1 MULTIVERT® NH 2 MSL Size 2, 400A / 690V Item 1-pole switchable NH 2 MSL bolt connection M 12 NH 2 MSL screw connection M 12 NH 2 MSL clamp strap with side connections Item 3-pole switchable NH 2 MSL bolt connection M 12 NH 2 MSL V-connection with 3 V-clamps NH 2 MSL press-in nut M 12 NH 2 MSL clamp strap with side connections MULTIVERT® NH 3 MSL Size 3, 630A / 690V Item 1-pole switchable NH 3 MSL bolt connection M 12 NH 3 MSL press-in nut M 12 NH 3 MSL clamp strap with side connections Item 3-pole switchable NH 3 MSL bolt connection M 12 NH 3 MSL V-connection with 3 V-clamps NH 3 MSL Einpressmutter M 12 NH 3 MSL clamp strap with side connections Versions with fuse monitoring and integrated converters on request. K’ELECTRIC WE CONNECT TO PROTECT 61 5.0 FUSES D0-Fuse links D0-Fuse links 400V~/250V-; DIN 49522 DIN VDE 0636 IEC 60269 Item Item-No. kg/pc. Packaging D01 2A D01 4A D01 6A D01 10A D01 13A D01 16A D02 20A D02 25A D02 32A D02 35A D02 40A D02 50A D02 63A 10 0202 10 0204 10 0206 10 0210 10 0213 10 0216 10 0220 10 0225 10 0232 10 0235 10 0240 10 0250 10 0263 0,10 0,10 0,10 0,11 0,11 0,11 0,18 0,18 0,19 0,21 0,21 0,22 0,22 50 50 50 50 50 50 50 50 50 50 50 50 50 Item-No. kg/pc. Packaging 10 1202 10 1204 10 1206 10 1210 10 1213 10 1216 10 1220 10 1225 10 1232 10 1235 10 1240 10 1250 10 1263 10 1200 0,10 0,10 0,10 0,11 0,11 0,11 0,18 0,18 0,19 0,21 0,21 0,22 0,22 2,10 1/24 1/24 1/24 1/24 1/24 1/24 1/12 1/12 1/12 1/12 1/12 1/12 1/12 1 Item-No. kg/pc. Packaging 14 0602 14 0604 14 0606 14 0610 14 0616 14 0620 14 0625 14 0632 14 0635 14 0640 14 0650 14 0663 14 0680 14 0690 14 0691 14 0692 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 3 3 3 3 9 9 9 9 9 9 9 9 9 9 3 3 The handy spare click box mounted in the distribution rack provides immediate swapping of fuses and reswitching Item 12X 2A D01 in Box 1,5TE 12X 4A D01 in Box 1,5TE 12X 6A D01 in Box 1,5TE 12X 10A D01 in Box 1,5TE 12X 13A D01 in Box 1,5TE 12X 16A D01 in Box 1,5TE 12X 20A D02 in Box 3TE 12X 25A D02 in Box 3TE 12X 32A D02 in Box 3TE 12X 35A D02 in Box 3TE 12X 40A D02 in Box 3TE 12X 50A D02 in Box 3TE 12X 63A D02 in Box 3TE Complete range 13X12 cartridge ring adaptors 2-63A NH-Fuse links with non-isolated gripping lugs, double indicator, contact blades, complying with DIN VDE 0632-2 Operating class (gL) gG Size 000/00 500~/250VItem 62 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 000 Size 00 Size 00 2A 4A 6A 10A 16A 20A 25A 32A 35A 40A 50A 63A 80A 100A 125A 160A Size 1 500~/440VItem Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Item-No. 14 1620 14 1625 14 1635 14 1650 14 1663 14 1680 14 1690 14 1691 14 1692 14 1693 14 1699 14 1694 20A 25A 35A 50A 63A 80A 100A 125A 160A 200A 224A 250A kg/pc. 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 0,12 Packaging 3 3 3 3 3 3 3 3 3 3 3 3 Size 2 500~/440VItem Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 50A 63A 80A 100A 125A 160A 200A 224A 250A 300A 315A 355A 400A Item-No. kg/pc. Packaging 14 2650 14 2663 14 2680 14 2690 14 2691 14 2692 14 2693 14 2699 14 2694 14 2695 14 2696 14 2698 14 2697 0,42 0,42 0,42 0,42 0,42 0,42 0,42 0,42 0,42 0,61 0,61 0,61 0,61 3 3 3 3 3 3 3 3 3 3 3 3 3 Item-No. kg/pc. Packaging 14 3696 14 3698 14 3629 14 3630 0,12 0,12 0,12 0,12 3 3 3 3 Item-No. kg/pc. Packaging 14 1710 14 1711 14 1712 14 1713 0,12 0,12 0,12 0,12 3 3 3 3 Size 3 500~/440VItem Size 3 Size 3 Size 3 Size 3 315A 400A 500A 630A NH-contact blades with non-isolated gripping lugs Item Size 00/000 Size 1 Size 2 Size 3 160A 250A 400A 630A K’ELECTRIC WE CONNECT TO PROTECT 63 D0-Cartridge ring adaptor insert D0-Cartridge ring adaptor inserts DIN 49523 DIN VDE 0636 IEC 60269 Item Item-No. kg/pc. D01 E14 2A D01 E14 4A D01 E14 6A D01 E14 10A D02 E18 2A D02 E18 4A D01 E18 6A D01 E18 10A D01 E18 16A D01 E18 20A D01 E18 25A D01 E18 35A D01 E18 50A 10 0302 10 0304 10 0306 10 0310 10 0402 10 0404 10 0406 10 0410 10 0416 10 0420 10 0425 10 0435 10 0450 0,001 0,001 0,001 0,001 0,001 0,001 0,001 0,001 0,001 0,001 0,001 0,001 0,001 Packaging 50 50 50 50 50 50 50 50 50 50 50 50 50 Item Item-No. kg/pc. 12X 2A D01 in a box 1,5TE 12X 4A D01 in a box 1,5TE 12X 6A D01 in a box 1,5TE 12X 10A D01 in a box 1,5TE 12X 2A D02 in a box 3TE 12X 4A D02 in a box 3TE 12X 6A D02 in a box 3TE 12X 10A D02 in a box 3TE 12X 16A D02 in a box 3TE 12X 20A D02 in a box 3TE 12X 25A D02 in a box 3TE 12X 35A D02 in a box 3TE 12X 50A D02 in a box 3TE 10 1302 10 1304 10 1306 10 1310 10 1402 10 1404 10 1406 10 1410 10 1416 10 1420 10 1425 10 1435 10 1450 0,03 0,03 0,03 0,03 0,03 0,03 0,03 0,03 0,03 0,03 0,03 0,03 0,03 Packaging 1/24 1/24 1/24 1/24 1/24 1/24 1/24 1/24 1/24 1/24 1/24 1/24 1/24 Complete range 13X12 fuse link sets 2-50A 10 1300 0,39 1 Item Item-No. kg/pc. Cartridge ring adaptor wrench Screw cap D02 plastic with testing hole Adapter ring for D01 fuse links Screw cap D02 porcelain with testing hole Screw cap D01 porcelain with testing hole 10 1400 12 6024 12 1401 12 7024 12 7025 0,02 0,01 0,01 0,01 0,01 Item Item-No. kg/pc. Reserve box pink Reserve box brown Reserve box green Reserve box red Reserve box grey Reserve box blue Reserve box yellow Reserve box black Reserve box white Reserve box ocher 10 1102 10 1104 10 1106 10 1110 10 1116 10 1120 10 1125 10 1135 10 1150 10 1163 0,04 0,04 0,04 0,04 0,04 0,04 0,04 0,04, 0,04 0,04 Accessories Packaging 1/12 20 50 20 20 Servicebox for the distribution rack as reserve box for small parts Fits in the standard distributor screen cutout 3 TE width (54mm) 64 Packaging 1/12 1/12 1/12 1/12 1/12 1/12 1/12 1/12 1/12 1/12 6.0 SUPERVISORY RELAY German German Production && Production Technology Technology Low voltage measuring relay - 3-phase supervision for low voltage and phase failure - Neutral supervision - Width 17,8mm (1 unit) - Switching voltage 85%, delay 0,5 sec; - Accords to DIN EN 50172 (DIN VDE 108-100) - Power consumption less than 1W - LED indication for phase and neutral faults K’ELECTRIC WE CONNECT TO PROTECT relay tv = 0,5s Principle of operation Low voltage monitoring for AC in 3-phase networks (each phase against N) with fixed adjusted switch level and fixed time delay.The relay is triggered off when the measured voltage of all connected phases exceeds the level of Us.The green LED lights up. As soon as the voltage of one of the connected phases sinks below the set value for longer than 0.5 seconds, the relay falls back to its starting position and the corresponding red LED will blink. If the voltage exceeds the level again for at least 0,5s, the relay switches back to normal operation. Item Item-No. kg/pc. Packaging Low voltage measuring relay 2 break contacts Low voltage measuring relay 1 break contact 10 3059 10 3060 0,10 0,10 1/18 1/18 65 Low voltage measuring relay with rotary field recognition - 3-phase supervision for low voltage and phase failure - Neutral supervision - Width 17,8mm (1 unit) - Switching voltage 85%, delay 0,5 sec; - Accords to DIN EN 50172 (DIN VDE 108-100) - Power consumption less than 1W - LED indication for phase and neutral faults, phase and N-fault - Test key Principle of operation Low voltage monitoring for AC in 3-phase networks (each phase against N) with fixed adjusted switch level and fixed time delay.The relay is triggered off when the measured voltage of all connected phases exceeds the level of Us.The green LED lights up. As soon as the voltage of one of the connected phases sinks below the set value for longer than 0.5 seconds, the relay falls back to its starting position and the corresponding red LED will flash. If the voltage exceeds the level again for at least 0,5s, the relay switches back to normal operation. If the phase (left run) changes, the relay likewise falls back in the initial position.The LED for phase flashes. Item Item-No. kg/pc. Packaging Low voltage-measure relay with phase recognition 2 break contacts 10 3061 0,10 1/18 Low voltage measuring relay with switch back delay - 3-phase supervision for low voltage and phase failure - Neutral supervision - Width 17,8mm (1 unit) - Switching voltage 85%, delay 0,5 sec; - Switch back delay - Accords to DIN VDE 100-718 - Power consumption less than 1W - LED indication for phase and neutral faults 66 relay tv = 1min Principle of operation Low voltage monitoring for AC in 3-phase networks (each phase against N) with fixed adjusted switch level and fixed time delay.The relay is triggered off when the measured voltage of all connected phases exceeds the level of Us.The green LED lights up. As soon as the voltage of one of the connected phases sinks below the set value for longer than 0.5 seconds, the relay falls back to its starting position and the corresponding red LED will flash. If the voltage exceeds the level again for at least 0,5s, the relay switches back to normal operation. Item Item-No. Low voltage measuring relay 2 break contacts 10 3062 kg/pc. Packaging 0,10 1/18 K’ELECTRIC WE CONNECT TO PROTECT Techncal data Operation temperature Temperaturbereich Lagerung Climate stability (DIN EN 0160/IEC 68) -25/+60°C -25/+60°C F / DIN 40040 Insulation parts Filament examination leakage current resistance Protection class / contact protection Plastic halogen and phosphate free 960° CTI 600 Finger and back of hand protection BGV A3 Standards DIN EN 61000 (EMC-failure safety) IEC/EN61000-4-2, IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 60255, DIN VDE 0435-300 DIN VDE 100-718 (103062) IP 40 - Housing IP 20 - Terminal 35mm Hutschiene DIN EN 50022 Mounting High voltage class (VDE 0100) (VDE 0100) III 2 Degree of pollution as per IEC 801 Teil 1-4 EMC-compatibility Supply Rated operational voltage Power consumption Rated frequency Rated electric strength Uimp Recommended fuse Relay contacts Rated operational current lowest operationl current/ voltage Connection terminals Rated cross section Torque 230/400V AC < 1VA 50-60Hz 4000V 6 A gG (gL) 250V / 5A AC 30V AC / 5A DC 300 / 0,25A DC 100mV / 10mA AC/DC 2,5mm2 (AWG14) flexible 4,0mm2 (AWG12) inflexible 0,5 Nm 67 German Production & Technology Low voltage monitoring relays, series USR Principle of operation If in one, two or three phases, the rated operation voltage Ue drops under Us level, then the relay switches back to its rest position.The LED extinguishes.This also happens in case of neutral failure. Functional display 1 LED 1 break contact; Us= 0,85 X Ue; tv = ca. 400msec 1 break contact/1 make contact; Us= 0,85 X Ue; tv = ca. 400msec 1 break contact/1 make contact; Us= 0,65…0,95 X Ue; tv = ca. 400msec 1 break contact/1 make contact; Us= 0,85 X Ue; tv = 0,1…5 sec 1 break contact/1 make contact; Us= 0,65…0,95 X Ue; tv = 0,1…5 sec Functional display 3 LED (for each phase) 1 break contact/1 make contact; Us= 0,85 X Ue; tv = ca. 400msec 1 break contact/1 make contact; Us= 0,65…0,95 X Ue tv = ca.400msec 1 break contact/1 make contact; Us= 0,85 X Ue; tv = 0,1…5 sec 1 break contact/1 make contact; Us= 0,65…0,95 X Ue; tv = 0,1…5 sec Item-No USR 3000 USR 3001 USR 3002 USR 3003 USR 3004 Packaging 3/60 3/60 3/60 3/60 3/60 USR 3005 USR 3006 USR 3007 USR 3008 3/60 3/60 3/60 3/60 These units are in compliance with DIN EN 50172 (DIN VDE 108-100). K’ELECTRIC WE CONNECT TO PROTECT Low and high voltage monitoring relays, series UER Principle of operation If in one, two or three phases, the rated voltage drops or exceeds Ue then the relay switches back to its rest position. If the switching point is above Uso then the green LED extinguishes and the yellow LED U>Us lights up. If the switching point is below Usu then the green LED extinguishes and the yellow LED U<Us lights up. Item/Function 230/400V AC 24V DC 24V AC 68 1 break contact; 1 make contact; 3 LEDs Usu= 0,65…0,95 X Ue ; Uso= 1,05…1,15 X Ue ; tv = ca. 400msec 2 break contacts; 3 LEDs Usu= 0,65…0,95 X Ue ; Uso= 1,05…1,15 X Ue ; tv = ca. 400msec 2 break contacts; 3 LEDs Usu= 0,65…0,95 X Ue ; Uso= 1,05…1,15 X Ue ; tv = ca. 400msec Item-No. UER 3011 Packaging 3/60 UER 3015 3/60 UER 3016 3/60 UBERWACHUNGRELAIS 7.0 DIGITALE CURRENT METER NOVA Three-phase meter with MID authentication for effect and reactive energy installation dimension 4TE - Digital three-phase meter up to 80A direct measurement - Digital three-phase transformer also for 5A und 1A - Adjustable (unlimited changeable) converter ratio - Double tariff meter HT/NT with tariff switching input - S0-output for active and reactive energy - Resettable partial counter - Optional extension through communication modules - Accuracy: active energy B (cll. 1), reactive energy A (cl. 2) - Made in EU, with EU wide valid MID certification 4 TE width (72 mm) Item Nova 80A MID -4L Nova 5/1A MID -4L communications module for the Nova-Serie Nova M-bus module Nova MOD-bus module RTU module Nova LAN-bus gateway module KNX module 3 PHASE - 4 CONDUCTORS - 3W 3 PHASE - 4 CONDUCTORS Installment dimension Type 4 TE direct measurement 4 TE converter measurement 1TE 1TE 2TE 1TE Item-No. 19 5500 19 5501 kg/pc. 0,5 0,4 19 5510 19 5511 19 5512 19 5513 0,1 0,1 0,15 0,1 69 German Production & Technology SINUS Three-phase meter without MID authentication for effect and reactive energy installation dimension 4TE - Digital three-phase meter up to 85A direct measurement - Digital three-phase transformer also for 5A und 1A - Adjustable (unlimited changeable) converter ratio - 2 N-clamp for branching connections - Double tariff meter HT/NT with tariff switching input - S0-output for active and reactive energy - Display of: V, A, W, VA, var, Hz and cos phi - Installment test - Optional supply with integrated M-BUS - Optional works adjustable S0 pulse amount and length - Accuracy: active energy B (cl. 1), reactive energy A (cl. 2) - Made in Germany - MID-certification in preparation 4 TE width (72 mm) Item Sinus 85 Sinus 5/1 Sinus 85 M-bus Sinus 5/1 M-bus Type direct measurement converter measurement direct measurement converter measurement Installment dimension 4 TE 4 TE 4 TE 4 TE Artikel-Nr. 19 5600 19 5601 19 5602 19 5603 VE 1 1 1 1 AC meter Electronic one phase AC meter for recording the flow amount 230V AC, 5(32)A, 50Hz S0-Interface with and without MID Zulasung M-bus interface in preparation 70 Item Alternating current meter without MID Alternating current meter with MID Alternating current meter with MID M-BUS i. vorb. Item-No. 19 5660 19 5661 19 5662 kg/pc. 0,10 0,10 0,10 Packaging 1 1 1 8.0 ACCESSORIES German Production & Technology 8.1 BUS BAR CONNECTORS Double clamp for TYTAN® II, CORON® 2 for branching connections Item 3-pole Item-No. 10 2013 Cross section 2x35mm2 Packaging 4 Bus bar connector for TYTAN® T Module width: 17,8mm; length 1000mm; cutable; branching connection Item 3-pole 4-pole Item-No. 11 1053 11 1054 No. of pegs 42 56 Cross section 30mm2 30mm2 End cap A6 A6 Packaging 10 10 Fixed length, unit width 17,8mm, including end caps, cross section 30mm; branching connection Artikel 2 X 3-pole; 30mm2 Item-No. 11 1223 11 1224 11 1233 11 1234 2 X 4-pole; 30mm2 3 X 3-pole; 30mm2 3 X 4-pole; 30mm2 Packaging 10 10 10 10 Power rating at 35°C ambient temp. depends on the final input point Supply at any one end of bus bar Bus bar cross section Max.. bus bar current Is/phase Other supply points Max. input Ie/phase Comb bus bars (1 pole) 10mm2 16mm2 25mm2 35mm2 63A 80A 100A 130A 100A 130A 180A 220A 10mm2 63A 100A Bus bar block ( multi pole) 16mm2 25mm2 30mm2 35mm2 80A 100A 120A 130A 130A 180A 180A 220A K’ELECTRIC WE CONNECT TO PROTECT Supply from near or far end of bus bar Other supply points Ie= aggregate Is In the case of supply in the middle, the sum of the loss currents S1…Sn should not exceed the specified max. bus bar current Is/phase 71 BUS BAR CONNECTORS Bus bar connectors for TYTAN® I Cross section: 16mm, unit width 17,8; length :1000mm cutable to size Artikel 1-pole; 90° hooked 2-pole 3-pole Item-No. 11 1061 11 1062 11 1063 End cap A11 A3 A3 Packaging 10 10 10 For fixed lengths no end caps necessary. Cross section 16mm2; Unit width 17,8mm not cutable. 11 1261 11 1262 11 1263 12 x 1 pole; length 210 mm 6 x 2 pole; length 212mm 4 x 3 pole; length 212mm 10 10 10 Bus bar systems for TYTAN® II, CORON® 2, D0-Fuse base Unit width ; 27mm; length 1000mm cutable. Item 1-pole; 90° hooked Item-No. 11 1071 11 1072 11 1073 11 1074 No. of pegs 37 38 39 40 2-pole 3-pole 4-pole 10 2021 10 2022 10 2023 10 2024 37 38 39 40 25mm2 25mm2 25mm2 25mm2 A20 A26 A26 A26+A20 10 10 10 10 1-pole; 90° hooked 2-pole 3-pole 4-pole 10 2031 10 2032 10 2033 10 2034 37 38 39 40 35mm2 35mm2 35mm2 35mm2 A20 A26 A26 A26+A20 10 10 10 10 End cap A1 End cap A2 End cap A3 End cap A5 End cap A6 End cap A11 End cap A20 End cap A26 11 1001 11 1002 11 1003 11 1005 11 1006 11 1011 11 1020 10 0262 2-pole 3-pole 4-pole 1-pole; 90° hooked Cross section 16mm2 16mm2 16mm2 16mm2 End cap A11 A1 A1 A2 Packaging 10 10 10 10 10 10 10 10 10 10 10 10 Fixed length, unit width 27mm, not cutable. Item 72 8 X 1-pole ; length 210mm; 16mm2 4 X 2-pole ; length 212mm; 16mm2 4 X 2-pole ; length 212mm; 25mm2 2 X 3-pole ; length 159mm; 16mm2 2 X 3-pole ; length 159mm; 25mm2 3 X 3-pole ; length 243mm; 16mm2 3 X 3-pole ; length 243mm; 25mm2 4 X 3-pole ; length 324mm; 16mm2 4 X 3-pole ; length 324mm; 25mm2 Item-No. 11 1271 11 1272 11 1282 11 1275 11 1285 11 1276 11 1286 11 1277 11 1278 Packaging 10 10 10 10 10 10 10 10 10 3-pole bus bar connectors Fork - and bridge bus bar connectors with 17, 8 mm module width bridge bus bar connectors 17, 6 mm module width for ABB and Siemens circuit breaker “simply plug - tighten - ready” about 30% time savings compared to metre lengths 3-pole fork-bus bar connectors, Module width 17,8mm for circuit breaker Item Fork Fork Fork Fork Item-No. 11 1245 11 1244 11 1243 11 1041 No. of pegs 6 9 12 57 Cross section 10mm2 10mm2 10mm2 10mm2 Length 105mm 159mm 212mm 1000mm End cap 11 1005 Packaging 10 10 10 10 3-pole bridge-bus bar connectors, Module width 17,8mm for circuit breaker Bridge Bridge Bridge Bridge 11 1248 11 1247 11 1246 11 1042 6 9 12 57 10mm2 10mm2 10mm2 10mm2 105mm 159mm 212mm 1000mm 11 1005 10 10 10 10 3-pole bridge-bus bar connectors, Module width 17,6mm for circuit breakers like ABB Siemens Bridge Bridge Bridge Bridge 11 1242 11 1241 11 1240 11 1040 6 9 12 57 10mm2 10mm2 10mm2 10mm2 105mm 159mm 212mm 1000mm 11 1005 10 10 10 10 - 10 10 10 3-pole bus bar connectors for FI/LS for fork, bridge combination 17,8mm for ABB and Siemens / 1 FI +8 LS Fork Bridge, 17,6mm Bridge, 17,8mm 11 1251 11 1250 11 1252 11 11 11 10mm2 10mm2 10mm2 212mm 212mm 212mm Blind cover for distributor shroud, 12 place units, 220mm long Blindcover for distributor shroud, grey, 12 place units Blindcover for distributor shroud, white, 12 place units 11 1400 50/500 11 1401 50/500 Contact protection for bus bar support contact protection for bus bar support, single detachable for 5TE 11 1249 10 all prices plus. metal surcharges 73 8.2 DIAGRAM POCKETS Diagram pocket 1013U-1 - diagram pocket grey - from polystyrene in RAL 7035 - impact resistant - self adhesive - screw fitting possible - size corresponds to DIN A4 - internal dimensions (HxWxD): 230mm x 220mm x 30mm Foil diagram pocket - self adhesive - size corresponds to DIN A4 - size (WxH): 230mm x 305mm Diagram pocket with extension fold - cardboard reinforced rear panel - just as deep as the documents - self adhesive - size corresponds to DIN A4 - rear panel (WxH): 250mm x 230mm - front pocket (HxWxD): 250mm x 190mm x 25mm Item plastic 230x220x30mm adhesive foil 230x305mm (DIN A4) adhesive reinforced cardboard with extension fold 74 Item-No. 19 5001 kg/pc. 0,15 19 5002 0,01 19 5003 0,05 Packaging 25 25 25 NOTES WE CONNECT TO PROTECT - K’ELECTRIC 75 K’ELECTRIC GMBH Carl-Benz-Straße 7 D-95448 Bayreuth Germany Telephone +49 (0) 921 151 26 78-0 Telefax +49 (0) 921 151 26 78-20 Mail [email protected] www.k-electric-gmbh.de ac-graphicdesign-1-14 K’ELECTRIC