NKE/PMS-Katalog/GB mit Bund

Transcription

NKE/PMS-Katalog/GB mit Bund
(
Patient Monitoring
Accessories
)
(
A l ways P e r f e c t l y B a l a n c e d :
O r i g i n a l a c c e s s o r i e s fo r o pt i m a l ex a m i n a t i o n r e s u l t s
)
Your patient is unique. Our accessories are original.
Health is man’s most valuable asset and therefore products that help to
preserve health are not to be equated with any other possessions. Espousing this
philosophy is something we consistently do, since we concentrate exclusively on
the development, manufacture, marketing and servicing of medical devices — an
activity we discharge not as a medical department or an enterprise sector within
a large concern with many business areas, but rather in our capacity as a large,
internationally reputed specialist enterprise for this specialist domain. We are
therefore able to target all our decision-making processes precisely towards
elucidating what is necessary and beneficial for this sensitive medical electronics
market.
In our view there is always a direct link between technical and methodical
innovations when it comes to research and development of the latest technologies. Only the synthesis of these two components will ensure that the human
being will really be the final focus of all efforts. Only those devices that, in
addition to optimal technology, are able to assure enhanced patient friendliness,
ease of operation and diagnostic accuracy will be placed on the market.
The direct interface to the patient is an essential feature of our highlydeveloped medical devices and systems. The method of signal acquisition plays a
pivotal role in collecting the requisite information for successful diagnosis and
therapy. We supply a comprehensive range of accessories and consumable
materials for each of our products. These are developed, tested and
manufactured together with the corresponding devices and are thus precisely
tailored to their technical requirements. This is because the quality and reliability
of medical devices and systems are inextricably bound up with the quality and
reliability of the accessories used.
Only the use of original accessories guarantees optimal examination results
and makes an important contribution towards ensuring that your device will
continue to function impeccably and reliably even in years to come, while
preserving the device’s features and functional capabilities.
With this catalogue we would now like to give you an overview of our accessories
and consumable materials.
I am delighted to have the pleasure of presenting this catalogue to you and hope
to have gained your interest in the products behind this quality philosophy!
Yours sincerely,
Dirk Mehlhorn
Head of Department for Technology and Quality Assurance
3
Highest Safety and Quality Standards
Our safety guide
Anyone manufacturing medical devices and accessories must have complete faith
in the technology, quality and reliability of their products. Prolonged trial phases,
continuous quality checks and state-of-the-art production facilities are indispensable prerequisites here.
This is because the target being aspired to is: absolute reliability, error-free
operation – especially during those decisive seconds. NIHON KOHDEN has
already taken appropriate in-depth measures here. The national and international
test standards regulating medical devices are stringent — but often not
sufficiently stringent as far as we are concerned. If we believe that the state-ofthe-art permits and warrants the use of even more exacting standards, then we
shall let these guide us.
Quality Assurance in Practice
A comprehensive quality assurance system ensures that each of the more
than 3,000 NIHON KOHDEN staff members makes his/her contribution towards
development, manufacture, marketing and customer services such that maximum
product quality is guaranteed.
NIHON KOHDEN is certified as per ISO 9001:2000, JIS Q 9001:2000, ISO
13485:1996, ISO 14001:1996, JIS Q 14001:1996 and ISO 13488:2001.
4
Trailblazers in Medical Technology
A lighthouse stands supreme, showing others the way. With the symbolic
light beam of our stylised lighthouse, we express our claim as well as our sense
of assurance of standing supreme, while at the same time playing a trailblazing
role.
As one of the leaders in innovation and technology we have specialized
exclusively in the field of medical technology.
Here we feel committed to progress in medicine.
Here we have our core competence.
Here, in the services of health, we find trailblazing solutions in the domains of
• Neurology
• Cardiology
• Patient monitoring
• Haematology
Fighting Disease with Electronics
NIHON KOHDEN shares with you a common goal: »Fighting Disease« – for the
health and quality of life of all patients. To that effect, we support your everyday
activities »with Electronics« – with technical product innovations in line with the
latest innovations in medical technology.
NIHON KOHDEN is active in research and development. The main focus of
our activities is on permanently improving diagnostic facilities. We develop all
devices for and together with our clients – in the services of the patient. Your
requirements and experiences gleaned from everyday practice always serve as
the cornerstone of our efforts. You are our yardstick when developing new
systems and technologies — from the most minute technical detail right up to the
complex system solution.
NIHON KOHDEN is Tradition and Future at the same time. With our
competence spanning more than 50 years, our various technological innovations
and ideas, we shall continue to be a strong partner for you in the future too.
Allow yourself to be convinced of the quality and functional capabilities of our
products, services and enterprise.
5
(
I n n ova t i o n s · H i g h l i g h t s
)
CapONE – CO2 Main stream sensor for capnography
Multi-parameter connection
NIHON KOHDEN patient monitors are equipped with innovative multi-parameter connectors. This unique technology offers high flexibility in terms of parameter selection.
The multi-parameter connector automatically detects the
sensor cable connected and independently configures the
patient monitor in accordance with the related parameter.
CapONE – innovative and extraordinary in
monitoring non-intubated patients:
No module needed – CapONE is a main stream sensor and does
not extract a gas sample from the patient’s respiratory flow.
High signal quality – CapONE measures close to the patient.
Its quality is particularly demonstrated in low-flow
respiration and oral breathing.
Extensive patient safety – CapONE needs no gas sampling line.
This reduces the risk of infection posed to the patient as a result
of a potentially contaminated gas sampling tube.
BluPRO® Sensors for SpO2 Measurement
Thanks to the consistent further development of its SpO2 sensor technology,
NIHON KOHDEN is once again able to demonstrate with the BluPRO® series of
probes just how precise and stable measurement results can be when measuring
arterial oxygen saturation.
Thanks to the parallel mounting of the sensor components, the reusable SpO2
sensor fits comfortably on any finger. Moreover, the mechanical design provides
for exact alignment of the optical components in respect of each other and
external light is effectively shielded out. The sensors are water tight and insensitive
to disinfectants.
The underlying philosophy when developing the single-use SpO2 sensors was
precise positioning of LED and photodetector. Therefore the two optical
components are designed with mechanical separation.
The paediatric version of the sensors features an additional child-friendly motif
series.
6
Contents
ECG and Respiration
Connection cables
ECG electrodes
Respiration (thermistor respiration measurement)
9 to 13
10
11 to 13
13
SpO2 Measurement
SpO2 connection cord
Reusable SpO2 probes
Disposable SpO2 probes
14 to 17
15
16
17
Temperature Measurement
18 to 19
Non-invasive Blood Pressure (NIBP)
Hoses
Cuffs (reusable, latex-free)
Disposable cuffs
20 to 23
21
22
23
Invasive Blood Pressure (IBP)
24 to 25
Cardiac Output (CO)
26 to 27
Capnography
Main stream method
CO2 calibration gas
Side stream method
28 to 32
29 to 31
31
32
FiO2 Measurement and Measurement of Anaesthetic Gas
FiO2 measurement
Measurement of anaesthetic gas
33 to 35
34
34 to 35
Dye Densitograph
Dye
Sensors
36 to 37
37
37
Other Accessories
Power cable
Cleaning pen
Touch pen
Connection cable for external equipment
38 to 39
39
39
39
39
Batteries
Batteries
Battery charger (external)
40 to 41
41
41
Recording Paper
42 to 43
Accessories for Telemetry Transmitter
ECG electrode leads
ECG electrodes
Reusable SpO2 probes
Disposable SpO2 probes
Cuffs (reusable, latex-free)
Bags
44 to 50
45
46 to 47
48
49
50
50
Warranty/Remarks
51 to 52
Index as per Supply Code No./Article No.
53 to 54
7
Overview of our Patient Monitoring Systems
The original accessories in this catalogue are optimally tailored to our patient monitors —
for reliable examination results and error-free operation of your equipment for many
years to come.
8
BSM-2300
BSM-4100
BSM-5100
BSM-9510
BSS-9800
OPV-1500
WEP-4200
WEP-8400
DDG-2001
ZB-810/811
ZB-820/823
ZB-930, ZS-930, ZM-930
ZB/ZS-910/920, ZM-920
ZS-940
(
ECG and Respiration
)
Connection cables · page 10
ECG electrodes · page 11 to 13
Respiration (thermistor respiration measurement) · page 13
9
BR-903P Electrode lead for 3 electrodes · clip type · cable length 0.8 m
Quantity
DDG-2001
WEP-4200/WEP-8400
OPV-1500 Lifescope N
BSM-9800 Lifescope S
BSM-9510 Lifescope M
R
x
x
x
x
x
x
1*
–
1
• K910A BR-913P Electrode lead for 3 electrodes · snap type · cable length 0.8 m
R
x
x
x
x
x
x
1*
–
1
• K912
BR-906P Electrode lead for 6 electrodes · clip type · cable length 0.8 m
R
x
x
x
x
x
–
1*
–
1
• K915
BR-916P Electrode lead for 6 electrodes · snap type · cable length 0.8 m
R
x
x
x
x
x
–
1*
–
1
• K922
JC-906P
Connection cord for connecting electrode lead K910, K911, K912
and K915 to patient monitor · cable length 3.0 m
R
x
x
x
x
x
–
1*
–
1
• L060
JC-103T
Connection cord for connecting electrode lead K910 and K911 to
patient monitor · cable length 3.0 m
R
–
–
–
–
–
x
1*
–
1
• K901
BJ-900P
ECG patient cable for 12 channel ECG · comprising electrode
lead and connection cord · cable length 3.8 m
R
–
x
x
x
x
–
1*
–
1
• K921
JC-900P
ECG patient cable for 12 channel ECG · for connection of disposable electrodes with DIN type connector (touch-proof) ·
cable length 3.0 m
R
–
x
x
x
x
–
1*
–
1
ECG connection cord cover for K922 connection cord
R
x
x
x
x
x
–
1*
–
1
• 6124-039432
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = see also section Accessories for Telemetry Transmitter
[1]
[1]
[2]
[2]
[1] K910A | [2] K911
[1] K915 | [2] K912
K922
L060
K901
K921
6124-039432
10
BSM-5100 Lifescope A
BSM-4100 Lifescope P
BSM-2300 Lifescope i/L
Description
Article No.
• K911
Disposable/Reusable/
Supplies
Connection Cables
Supply Code No.
ECG AND RESPIRATION
ECG and Respiration (Impedance Method)
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
D-90
Vitrode D · disposable ECG electrode · electrode material:
D
Ag/AgCl · size: ca. 55 mm dia · applicable for X-ray, CT and MRT ·
patent pending electrode adhesive (2-dimensional elastic for
tension) · very kind to the skin · suitable for long term
measurements (> 72 h) · wash-, shower- and bath-tolerant ·
for universal use
x
x
x
x
x
x
1*
–
30 x 3
• G207
L-150X
Vitrode L · disposable ECG electrode · electrode material:
D
Ag/AgCl · size: ca. 35 mm dia · applicable for X-ray, CT and MRT ·
strong adhesive · resistant against detachment by solvents ·
foam tape · for universal use
x
x
x
x
x
x
1*
–
5 x 30
• G210C F-150S
Vitrode F · disposable ECG electrode (small) · electrode
material: Ag/AgCl · size: ca. 18 mm x 36 mm · cotton tape ·
electrically conductive adhesive gel · repeatedly positionable ·
very kind to the skin · very suitable for children · not for use
in operating rooms
D
x
x
x
x
x
x
1*
–
50 x 3
• G210D F-150M
Vitrode F · disposable ECG electrode (medium) · electrode
material: Ag/AgCl · size: ca. 25 mm x 45 mm · cotton tape ·
electrically conductive adhesive gel · repeatedly positionable ·
very kind to the skin · not for use in operating rooms
D
x
x
x
x
x
x
1*
–
50 x 3
• G201
Bs-150
Vitrode Bs · disposable ECG electrode · electrode material:
Ag/AgCl · size: ca. 47 mm x 47 mm · soft breathable cotton tape
with an elastic quality for tension · hydro gel for low electrode
impedance and stable measurements even on dry skin ·
for universal use
D
x
x
x
x
x
x
1*
–
30 x 5
• G204
C-150
Vitrode C · disposable ECG electrode · electrode material:
Ag/AgCl · size: ca. 47 mm x 47 mm · soft breathable cotton tape
with an elastic quality for tension · hydro gel for low electrode
impedance and stable measurements even on dry skin ·
the electrode gel is almost removed after removing the
electrode · for universal use
D
x
x
x
x
x
x
1*
–
30 x 5
Disposable/Reusable/
Supplies
Description
• G217
Supply Code No.
Article No.
ECG Electrodes
ECG AND RESPIRATION
ECG and Respiration (Impedance Method)
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = see also section Accessories for Telemetry Transmitter
G217
G207
G210C
G210D
G201
G204
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
11
ECG Electrodes
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
J-150
Vitrode J · disposable ECG electrode · electrode material:
D
Ag/AgCl · size: ca. 40 mm dia · foam tape with excellent adhesion
unaffected by the effects of sweat or solvents · hydro gel for
low electrode impedance and stable measurements even on dry
skin · the electrode gel is almost removed after removing the
electrode · for universal use
x
x
x
x
x
x
1*
–
30 x 5
• G272A V-090M3 Vitrode V · disposable ECG electrode · electrode material:
D
Ag/AgCl · size: ca. 25 mm x 45 mm · DIN type connector
(touch-proof) with 100 cm electrode lead · electrode and cable
applicable for X-ray, CT and MRT · conductive hydro gel with
excellent adhesive advantages · foam and cotton tape · for universal
use · 3 electrodes for ECG monitoring · coloured cable
(red, yellow, green)
x
x
x
x
x
x
–
–
30 x 3
• G272B V-040M4 Vitrode V · disposable ECG electrode · same as G272A, but
with 4 electrodes for limb leads · coloured cable (red, yellow,
green, black)
D
x
x
x
x
x
x
–
–
10 x 4
• G272C V-060M6 Vitrode V · disposable ECG electrode · same as G272A, but
with 6 electrodes for chest leads · coloured cable (red, yellow,
green, brown, black, purple)
D
x
x
x
x
x
x
–
–
10 x 6
• G271K V-120SK Vitrode V-s · disposable ECG electrode · electrode material:
D
Ag/AgCl · size: ca. 20 mm x 20 mm · DIN type connector
(touch-proof) with 60 cm electrode lead · electrode and cable
applicable for X-ray, CT and MRT · foam and cotton tape with
excellent adhesive advantages · very kind to the skin · very small –
for neonates and infants · child friendly with motif print »Kitty« ·
coloured cable (red, yellow, green)
x
x
x
x
x
x
–
–
40 x 3
• G271A V-120S3 Vitrode V · disposable ECG electrode · same as G271K, but
without motif print
x
x
x
x
x
x
–
–
40 x 3
• G250
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = see also section Accessories for Telemetry Transmitter
12
Disposable/Reusable/
Supplies
BSM-9510 Lifescope M
G271A
BSM-5100 Lifescope A
G271K
BSM-4100 Lifescope P
G272C
BSM-2300 Lifescope i/L
G272B
Description
G272A
Article No.
G250
Supply Code No.
ECG AND RESPIRATION
ECG and Respiration (Impedance Method)
D
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
Description
Article No.
Supply Code No.
ECG Electrodes
D
x
x
x
x
x
x
1*
–
10 x 3
D
x
x
x
x
x
x
1*
–
• G300A N-03IS3
Vitrode N · disposable ECG electrode · electrode material:
Ag/AgCl · size: ca. 14 mm x 25 mm · DIN type connector
(touch-proof) with 60 cm electrode lead · electrode and cable
applicable for X-ray, CT and MRT · fleece tape with excellent
adhesive advantages · very kind to the skin · very small – for
neonates and infants · child friendly with motif print »Sweezy« ·
coloured cable (red, yellow, green)
• NKD-H34SG
30
Disposable ECG electrode ARBO® · size: ca. 45 mm dia · applicable
ECG AND RESPIRATION
ECG and Respiration (Impedance Method) · Respiration (Thermistor Respiration Measurement)
for X-ray, CT and MRT · hydro gel · very strong adhesive ·
72 h endurance test · shower- and wash-tolerant · with skin
remover
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = see also section Accessories for Telemetry Transmitter
G300A
NKD-H34SG
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
x
x
x
x
x
–
–
–
1
• P902
TR-910P
R
x
x
x
x
x
–
–
–
1
• V911
YG-001P Airway adapter for respiration pickup P902
D
x
x
x
x
x
–
–
–
1
Description
Disposable/Reusable/
Supplies
TR-900P Respiration pickup for air flow measurement · placed at the nose · R
applicable for spontaneous breathing patients · cable length
3.0 m
Article No.
• P901
Supply Code No.
BSM-2300 Lifescope i/L
Respiration (Thermistor Respiration Measurement)
Respiration pickup for air flow measurement · applicable for
artificially respirated patients · Airway adapter V911 is needed ·
cable length 3.0 m
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
P901
P902
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
V911
13
(
SpO2 Measurement
)
SpO2 connection cord · page 15
Reusable SpO2 probes · page 16
Disposable SpO2 probes · page 17
14
Description
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
• K931
JL-900P
SpO2 connection cord · for connecting SpO2 probes to the
patient monitor · with protective cap for probe connector ·
cable length 2.5 m
R
x
x
x
x
x
–
–
–
1
• L311
JL-302T
SpO2 connection cord · for connecting SpO2 probes to the
patient monitor · with protective cap for probe connector ·
cable length 2.5 m
R
–
–
–
–
–
x
–
–
1
Supply Code No.
Article No.
SpO2 Connection Cord
S p O2 M E A S U R E M E N T
SpO2 Measurement
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
K931

L311
1972 Development of Measurement Method for the Pulsoximetry (SpO2 Measurement)
The method for determination of arterial oxygen saturation, based on the
photoelectric plethysmography, was conceptualised and implemented in 1972 by
the Japanese bio-engineer Takuo Aoyagi (NIHON KOHDEN Corporation). This idea
came about while using an ear densitometer for recording dilution curves for dyes
(pigments). The first commercial oximeter »OLV-5100« was presented by
NIHON KOHDEN back in 1975.
This method has been used worldwide since the late 1970s and has since then
been further refined by many manufacturers.
The NIHON KOHDEN SpO2 sensors of the BluPRO®-Series are at the cutting edge
of this progressive technology.
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
15
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
Finger probe · for adults and children with a weight of more
than 20 kg · cable length 1.6 m
R
x
x
x
x
x
–
1*
–
1
• P225F TL-201T
Finger probe BluPRO® series · for adults and children with a
weight of more than 20 kg · cable length 1.6 m
R
x
x
x
x
x
x
1*
–
1
• P225G TL-220T
Multi-site probe BluPRO® series · for adults and children with R
a weight of more than 3 kg · cable length 1.6 m
x
x
x
x
x
x
1*
–
1
• P205A TL-260T
Multi-site Y probe · for neonates and infants (semi disposable) · R
cable length 1.6 m
x
x
x
x
x
x
1*
–
5
R
x
x
x
x
x
x
1*
–
1
• P260A 6143-011854 Sponge attachment tape S for multi-site Y probe P205A
S
x
x
x
x
x
x
1*
–
24
• P260B 6143-011863 Sponge attachment tape L for multi-site Y probe P205A
S
x
x
x
x
x
x
1*
–
24
• P256
Description
• P224A TL-101T
Article No.
Disposable/Reusable/
Supplies
Reusable SpO2 Probes
Supply Code No.
S p O2 M E A S U R E M E N T
SpO2 Measurement
6143-012434 Ear clip for multi-site Y probe P205A (no illustration)
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = see also section Accessories for Telemetry Transmitter
P224A
16
P225F
P225G
P260A
P260B
P205A
S p O2 M E A S U R E M E N T
SpO2 Measurement
Disposable SpO2 Probes
[1]
[1]
[2]
[2]
[3]
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
D
x
x
x
x
x
x
1*
–
5
• P201B TL-252T
Disposable probe BluPRO® series for finger or toe · for
children with a weight between 3 kg and 40 kg · cable
length 1.6 m
D
x
x
x
x
x
x
1*
–
5
• P201A TL-251T
Disposable probe BluPRO® series for finger or toe · for adults D
with a weight of more than 30 kg · cable length 1.6 m
x
x
x
x
x
x
1*
–
5
• P229A TL-061S
Disposable probe · for adults and children with a weight
between 15 kg and 50 kg (finger probe) and/or children with
a weight between 3 kg and 15 kg (toe probe) · cable
length 0.8 m
D
x
x
x
x
x
x
1*
–
5
• P229B TL-062S
Disposable probe · same as P229A, but cable length 1.6 m
D
x
x
x
x
x
x
1*
–
5
• P228A TL-051S
Disposable probe · for adults with a weight more than 50 kg
(finger probe) and/or neonates with a weight less than 3 kg
(foot probe) · cable length 0.8 m
D
x
x
x
x
x
x
1*
–
5
• P228B TL-052S
Disposable probe · same as P228A, but cable length 1.6 m
D
x
x
x
x
x
x
1*
–
5
• P259
COTTONY tape for fixing the disposable probes
S
x
x
x
x
x
x
1*
–
20
340703
Description
Disposable probe BluPRO® series for foot · for infants with a
weight of less than 3 kg · cable length 1.6 m
Article No.
• P201C TL-253T
Supply Code No.
BSM-4100 Lifescope P
P259
BSM-2300 Lifescope i/L
[1] P228A | P228B | [2] P229A | P229B
Disposable/Reusable/
Supplies
[1] P201A | [2] P201B | [3] P201C
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = see also section Accessories for Telemetry Transmitter
 BluPRO®-SpO2 Sensors
The sensors of the BluPRO® series are water tight, so you can clean them under running water or even immerse them in a soapy
alkaline or disinfectant solution (glutaraldehyde solution 2.0 % or hydrochloric alkyl diaminoethylene glycine 0.5 %)!
In the finger version of the sensor, the sensor upper and lower shells are mounted in parallel thus, providing, on the one hand, exact
alignment of the optical sensor components vis-à-vis one another and, on the other hand, markedly enhanced comfort during longterm wear.
In addition, flexible lateral flaps shield out external light, thus preventing corruption of the measuring signals as a result of additional artificial light sources!
The single-use versions place special emphasis on exact positioning of LED and photodetector. For this reason the two optical
components are designed separately and can thus be brought into precise alignment with each other by the user.
The outcome of these myriad innovative detailed solutions is more precise and more stable measurement results.
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
17
(
Te m p e r a t u r e M e a s u r e m e n t
)
Temperature measurement · page 19
18
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
Temperature sensor for adults (esophagus, rectum) ·
6.3 mm Ø miniature jack · cable length 3.5 m
R
x
x
x
x
x
–
–
–
1
• NKD-P241A
Temperature sensor for children (esophagus, rectum) ·
6.3 mm Ø miniature jack · cable length 3.5 m
R
x
x
x
x
x
–
–
–
1
• NKD-P242A YSI-409A Temperature sensor for body surface · 6.3 mm Ø
miniature jack · cable length 3.5 m
R
x
x
x
x
x
–
–
–
1
• K961
Connection cable for temperature sensors · for
connecting of two temperature sensors with 6.3 mm Ø
miniature jacks to a multi-parameter socket · cable
length 0.3 m
R
–
x
x
x
x
–
–
–
1
Probe cover for temperature sensor NKD-P240A
(illustration similar to NKD-P249S)
D
x
x
x
x
x
–
–
–
10
Probe cover for temperature sensor NKD-P240A
D
x
x
x
x
x
–
–
–
100
Probe cover for temperature sensor NKD-P241A
(illustration similar to NKD-P249S)
D
x
x
x
x
x
–
–
–
100
Article No.
Description
• NKD-P240A YSI-401
Supply Code No.
Disposable/Reusable/
Supplies
Temperature Measurement
YSI-402
JT-900P
• NKD-P249
• NKD-P249S
ASR618a
• NKD-P249M ASR618
TEMPERATURE MEASUREMENT
Temperature Measurement
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1]
K961
NKD-P249S
[2]
[3]
[1] NKD-P242A | [2] NKD-P241A
[3] NKD-P240A
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
19
(
N o n - i nva s i ve B l o o d P r e s s u r e ( N I B P )
)
Hoses · page 21
Cuffs (reusable, latex-free) · page 22
Disposable cuffs · page 23
20
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
R
x
x
x
x
x
–
–
–
1
• S902
YN-901P Hose for cuffs for adults and children · NK bayonet joint ·
double hose system · hose length 3.5 m
R
x
x
x
x
x
–
–
–
1
• S904
YN-920P Hose for disposable cuffs for neonates · cone joint · double
hose system · hose length 1.5 m
R
x
x
x
x
x
–
–
–
1
• S905
YN-921P Hose for disposable cuffs for neonates · cone joint · double
hose system · hose length 3.5 m
R
x
x
x
x
x
–
–
–
1
• S929A YN-100T Hose for cuffs for adults and children · NK bayonet joint ·
double hose system · hose length 1.5 m
R
–
–
–
–
–
x
–
–
1
• S929B YN-101T Hose for cuffs for adults and children · NK bayonet joint ·
double hose system · hose length 3.5 m
R
–
–
–
–
–
x
–
–
1
• S930A YN-120T Hose for disposable cuffs for neonates · cone joint · double
hose system · hose length 1.5 m
R
–
–
–
–
–
x
–
–
1
• S930B YN-121T Hose for disposable cuffs for neonates · cone joint · double
hose system · hose length 3.5 m
R
–
–
–
–
–
x
–
–
1
• S903
R
x
x
x
x
x
x
–
–
1
Description
YN-900P Hose for cuffs for adults and children · NK bayonet joint ·
double hose system · hose length 1.5 m
Article No.
• S901
Supply Code No.
Disposable/Reusable/
Supplies
Hoses
YN-990P Extension hose · to extend the hoses S901, S902, S929A and
S929B with NK bayonet joint · hose length 1.5 m
NON-INVASIVE BLOOD PRESSURE
Non-invasive Blood Pressure (NIBP)
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[2]
[1]
[2]
[1]
[1] S901 | [2] S902
[1] S904 | [2] S905
S929A | S929B
S930A | S930B
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
S903
21
NON-INVASIVE BLOOD PRESSURE
Non-invasive Blood Pressure (NIBP)
Cuffs (reusable, latex-free)
[6]
[5]
[1]
[2]
[3]
[4]
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
x
x
x
x
x
x
–
–
1
• S943B YP-961T
R
x
x
x
x
x
x
–
–
1
• S943C YP-962T Cuff for children · width 10 cm · for circumference of 15 – 23 cm · R
latex-free · NK bayonet joint on 15 cm connection hose ·
Velcro fastening
x
x
x
x
x
x
–
–
1
• S944B YP-963T Cuff for adults · width 13 cm · for circumference of 21 – 30 cm ·
latex-free · NK bayonet joint on 15 cm connection hose ·
Velcro fastening
R
x
x
x
x
x
x
–
–
1
• S944C YP-964T Cuff for adults · width 15 cm · for circumference of 26 – 36 cm ·
latex-free · NK bayonet joint on 15 cm connection hose ·
Velcro fastening
R
x
x
x
x
x
x
–
–
1
• S944D YP-965T Cuff for adults · width 19 cm · for circumference of 33– 45 cm ·
latex-free · NK bayonet joint on 15 cm connection hose ·
Velcro fastening
R
x
x
x
x
x
x
–
–
1
Description
R
Article No.
• S943A YP-960T Cuff for infants · width 5 cm · for circumference of 8 –13 cm ·
latex-free · NK bayonet joint on 15 cm connection hose ·
Velcro fastening
Supply Code No.
Disposable/Reusable/
Supplies
[1] S943A | [2] S943B | [3] S943C | [4] S944B | [5] S944C | [6] S944D
Cuff for children · width 7 cm · for circumference of 12 –18 cm ·
latex-free · NK bayonet joint on 15 cm connection hose ·
Velcro fastening
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
22
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
Cuff for neonates · width 2.5 cm · cone joint on 15 cm
connection hose
D
x
x
x
x
x
x
–
–
10
• YP-921P
Cuff for neonates · width 3 cm · cone joint on 15 cm
connection hose
D
x
x
x
x
x
x
–
–
10
• YP-922P
Cuff for neonates · width 4 cm · cone joint on 15 cm
connection hose
D
x
x
x
x
x
x
–
–
10
Cuff for neonates · width 5 cm · cone joint on 15 cm
connection hose
D
x
x
x
x
x
x
–
–
10
Cuff for infants · width 6 cm · NK bayonet joint on 20 cm
connection hose
D
x
x
x
x
x
x
–
–
20
• YP-912P
Cuff for children · width 9 cm · NK bayonet joint on 20 cm
connection hose
D
x
x
x
x
x
x
–
–
20
• YP-913P
Cuff for adults · width 12 cm · NK bayonet joint on 20 cm
connection hose
D
x
x
x
x
x
x
–
–
20
Cuff for adults · width 14 cm · NK bayonet joint on 20 cm
connection hose
D
x
x
x
x
x
x
–
–
20
Cuff for adults · width 16 cm · NK bayonet joint on 20 cm
connection hose
D
x
x
x
x
x
x
–
–
20
Cuff for adults · width 20 cm · NK bayonet joint on 20 cm
connection hose
D
x
x
x
x
x
x
–
–
20
Description
Supply Code No.
Disposable/Reusable/
Supplies
Disposable Cuffs
• YP-920P
• YP-923P
• YP-910P
• YP-914P
• YP-915P
• YP-916P
NON-INVASIVE BLOOD PRESSURE
Non-invasive Blood Pressure (NIBP)
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1]
[2]
[3]
[4]
[1] YP-920P | [2] YP-921P | [3] YP-922P
[1]
[2]
[1] YP-910P | [2] YP-912P
[4] YP-923P
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
[1]
[2]
[3]
[4]
[1] YP-913P | [2] YP-914P | [3] YP-915P
[4] YP-916P
23
(
I nva s i ve B l o o d P r e s s u r e ( I B P )
)
Invasive Blood Pressure (IBP) · page 25
24
Description
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
• K951
JP-900P
Connection cord for invasive blood pressure · for Becton
Dickinson (Ohmeda) transducer (e.g. TP 400T) · cord
length 3.5 m
R
x
x
x
x
x
–
–
–
1
• K952
JP-910P
Connection cord for invasive blood pressure · transduceradapter cable · for Becton Dickinson (Ohmeda) transducer
(e.g. P23XL-1, P10EZ-1) · cord length 0.3 m
R
x
x
x
x
x
–
–
–
1
• L901
JP-920P
Connection cord for invasive blood pressure · for Baxter
(Edwards) transducer · cord length 3.5 m
R
x
x
x
x
x
–
–
–
1
Supply Code No.
Article No.
Invasive Blood Pressure
INVASIVE BLOOD PRESSURE
Invasive Blood Pressure (IBP)
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
K951
K952
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
L901
25
(
Cardiac Output (CO)
)
Cardiac Output (CO) · page 27
26
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
x
x
x
x
–
–
–
1
CO extension cable · cable length 1.0 m
R
–
x
x
x
x
–
–
–
1
• NKD-SP4045
684062 Inline sensor connection cable Becton Dickinson
D
–
x
x
x
x
–
–
–
1
• NKD-SP5107H
680078 Thermodilution catheter Becton Dickinson 7F · length
1.1 m (no illustration)
D
–
x
x
x
x
–
–
–
5
• NKD-SP5107H-IS 680077 Thermodilution catheter Becton Dickinson with inline
sensor 7F · length 1.1 m (no illustration)
D
–
x
x
x
x
–
–
–
5
• NKD-SP4500
680000 Inline iced injectate kit with injectate sensor housing
(illustration similar to NKD-SP5045)
D
–
x
x
x
x
–
–
–
4
• NKD-SP4572
680178 Room temperature injectate kit with injectate sensor
housing (illustration similar to NKD-SP5045)
D
–
x
x
x
x
–
–
–
5
• NKD-SP5045
680006 Injectate sensor housing for inline measurement of
injectate temperature with sensor cable
D
–
x
x
x
x
–
–
–
25
• SP-4035-1
Description
–
• K962
Article No.
R
Supply Code No.
Disposable/Reusable/
Supplies
Cardiac Output
JT-950P Connection cord for catheter and temperature measurement (Baxter and Becton Dickinson) · cord length 2.0 m
CARDIAC OUTPUT
Cardiac Output (CO)
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
K962
SP-4035-1
NKD-SP4045
NKD-SP5045
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
27
(
C a p n o g r a p hy
)
Main stream method · page 29 to 31
CO2 calibration gas · page 31
Side stream method · page 32
28
CAPNOGRAPHY
Capnography
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
x
x
x
–
–
–
1
R
x
x
x
x
x
–
–
–
1
R
x
x
x
x
x
–
–
–
1
YG-120T Disposable nasal adapter for CapONE · for expiratory
information · rejects condensates · short starting time of
5 s only
D
x
x
x
x
x
–
–
–
30
• V922
YG-121T
D
x
x
x
x
x
–
–
–
30
• V923
YG-122T Disposable nasal adapter with O2 tube for CapONE · for
expiratory information · rejects condensates · during
supply of O2 with face mask or O2 tube the capnogram can
be constantly displayed without any distortion
D
x
x
x
x
x
–
–
–
30
Description
Disposable/Reusable/
Supplies
x
Article No.
x
Supply Code No.
BSM-2300 Lifescope i/L
Main stream Method
• P907
TG-920P CO2 sensor kit CapONE · it includes CO2 sensor P923 and
R
CO2 adapter K984 · main stream CO2 sensor for nonintubated patients · for expiratory information · new
measurement technique decreases the number of false alarms ·
for connection to a multi-parameter socket · includes data
processing hardware · maintenance-free · cable length 3.5 m
• P923
TG-921T
CO2 sensor CapONE · for non-intubated patients · for
expiratory information · for connection to the CO2 adapter
K984 · exceptionally shockproof · cable length 1.5 m
• K984
JG-920P
CO2 adapter CapONE · for non-intubated patients · for
expiratory information · for connection to a multi-parameter
socket · includes data processing hardware · cable length
2.0 m
• V921
Disposable nasal adapter for CapONE · for expiratory
information · rejects condensates
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
P907
P923
K984
V921
V922
V923
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
29
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
x
x
x
x
–
–
–
1
R
x
x
x
x
x
–
–
–
1
CO2 adapter · for intubated patients · for expiratory
information · for connection to a multi-parameter socket ·
includes data processing hardware · cable length 2.0 m
R
x
x
x
x
x
–
–
–
1
Airway adapter without heater · rejects condensates ·
short starting time of 5 s only · 5 ml dead space volume
D
x
x
x
x
x
–
–
–
50
R
x
x
x
x
x
–
–
–
1
R
x
x
x
x
x
–
–
–
1
Disposable/Reusable/
Supplies
x
Description
Article No.
Main stream Method
Supply Code No.
CAPNOGRAPHY
Capnography
• P903*
TG-900P CO2 sensor kit · it includes CO2 sensor P922A and CO2
R
adapter K981 · main stream CO2 sensor for intubated
patients · for expiratory information · for connection to a
multi-parameter socket · includes data processing hardware ·
maintenance-free · cable length 3.0 m
• P922A
TG-101T
CO2 sensor · for intubated patients · for expiratory information · for connection to the CO2 adapter K981 ·
exceptionally shockproof · cable length 1.0 m
• K981
JG-900P
• R801
YG-101T
• P905
TG-950P CO2 sensor kit · it includes CO2 sensor P921 and CO2
adapter K982 · for intubated patients · for inspiratory and
expiratory information · for connection to a multi-parameter
socket · includes data processing hardware · maintenancefree · cable length 4.0 m
• P921
TG-201T
CO2 sensor · for intubated patients · for inspiratory and
expiratory information · for connection to the CO2 adapter
K982 · exceptionally shockproof · cable length 2.0 m
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[*] Attention during anaesthesia! Especially during the use of closed respiration circuits (CO2 returned respiration)!
The sensor does not measure inspiratory CO2 concentrations!
30
P903
P922A
K981
R801
P905
P921
CAPNOGRAPHY
Capnography
Main stream Method
[2]
[1]
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
• K982
JG-950P
CO2 adapter · for intubated patients · for inspiratory and
expiratory information · for connection to a multi-parameter
socket · includes data processing hardware · cable length
2.0 m
R
x
x
x
x
x
–
–
–
1
• R802
YG-201T Airway adapter without heater · for adults and children with
a weight of more than 10 kg · rejects condensates · short
starting time of 5 s only · 5 ml dead space volume
D
x
x
x
x
x
–
–
–
30
• R803
YG-202T Airway adapter without heater · for children and neonates
D
with a weight between 3 kg and 10 kg · rejects condensates ·
short starting time of 5 s only · 2 ml dead space volume
x
x
x
x
x
–
–
–
30
Supply Code No.
Description
[1] R802 | [2] R803
Article No.
K982
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
CO2 calibration gas · 200 g gas cylinder
R
x
x
x
x
x
–
–
–
1
Flow regulator
S
x
x
x
x
x
–
–
–
1
Description
• NKD-CO2Gas
• NKD-Ventil
Supply Code No.
Disposable/Reusable/
Supplies
CO2 Calibration Gas
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
NKD-CO2Gas
NKD-Ventil
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
31
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
• V907C
YG-914P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube
for non-intubated neonates · tube length 2.5 m
D
x
x
x
x
x
–
–
–
25
• V907B
YG-913P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube
for non-intubated children · tube length 2.5 m
D
x
x
x
x
x
–
–
–
25
• V907A
YG-912P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube
for non-intubated adults · tube length 2.5 m
D
x
x
x
x
x
–
–
–
25
• NKD-006342
FilterLine (H) for neonates and infants · for use together with D
humidifier · max. 72 h continuous operation · 0.5 ml dead
space volume · tube length 2.0 m
x
x
x
x
x
–
–
–
25
• NKD-XS04624
FilterLine (H) for adults and children · for use together with
humidifier · max. 72 h continuous operation · 7.3 ml dead
space volume · tube length 2.0 m
D
x
x
x
x
x
–
–
–
25
• NKD-XS04620
FilterLine (H) for adults and children · for use without
humidifier · max. 6 h continuous operation · 7.3 ml dead
space volume · tube length 2.0 m
D
x
x
x
x
x
–
–
–
25
• V903F
618877
Microstream (TM) Airway adapter · for neonates and infants · D
0.5 ml dead space volume
x
x
x
x
x
–
–
–
25
• V903E
YG-904P Microstream (TM) Airway adapter · for adults · 7.3 ml dead
space volume
D
x
x
x
x
x
–
–
–
25
• V901
YG-920P Exhaust gas adapter · tube length 3.0 m
R
x
x
x
x
x
–
–
–
1
Article No.
Description
Disposable/Reusable/
Supplies
Side stream Method
Supply Code No.
CAPNOGRAPHY
Capnography
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1]
[2]
[1] V907A | [2] V907B | [3] V907C
[3]
[1]
[1] NKD-006342 | [2] NKD-XS04624
[3] NKD-XS04620
V903E
32
[2]
V901
[3]
V903F
(
FiO2 Measurement and Measurement of Anaesthetic Gas
)
FiO2 measurement · page 34
Measurement of anaesthetic gas · page 34 to 35
33
Description
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
• P911
074705
O2 sensor · coiled cord · cable length 0.6 m
R
–
x
x
x
x
–
–
–
1
• K941
JO-900P
Connection cable for O2 sensor · for connection to a multiparameter socket · cable length 3.0 m
R
–
x
x
x
x
–
–
–
1
• V912
110774
T-adapter for O2 measurement (connection of the O2 sensor) D
–
x
x
x
x
–
–
–
1
Supply Code No.
Article No.
FiO2 Measurement
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
P911
K941
V912
Article No.
Description
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
Measurement of Anaesthetic Gas
• NKD-V915B
613721
Dryline water trap · for children and neonates
R
–
x
x
–
x
–
–
–
10
• NKD-V915A
613712
Dryline water trap · for adults
R
–
x
x
–
x
–
–
–
10
• NKD-V916A
613739
Dryline Airway adapter · straight
D
–
x
x
–
x
–
–
–
10
Supply Code No.
MEASUREMENT OF ANAESTHETIC GAS
FIO2 MEASUREMENT ·
FiO2 Measurement · Measurement of Anaesthetic Gas
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
NKD-V915B
34
NKD-V915A
NKD-V916A
MEASUREMENT OF ANAESTHETIC GAS
Measurement of Anaesthetic Gas
NKD-V916B
V903E
V903F
NKD-V917B
NKD-V917A
NKD-Scottgas
FIO2 MEASUREMENT ·
Measurement of Anaesthetic Gas
• NKD-V917B
• NKD-V917A
613775
613766
WEP-4200/WEP-8400
DDG-2001
Quantity
618877
OPV-1500 Lifescope N
• V903F
BSM-9800 Lifescope S
YG-904P Microstream (TM) Airway adapter · for adults · 7.3 ml
dead space volume
BSM-9510 Lifescope M
• V903E
BSM-5100 Lifescope A
Dryline Airway adapter · elbow
BSM-4100 Lifescope P
613748
BSM-2300 Lifescope i/L
Description
• NKD-V916B
Disposable/Reusable/
Supplies
Article No.
Supply Code No.
611358
D
–
x
x
–
x
–
–
–
10
D
–
x
x
–
x
–
–
–
25
Microstream (TM) Airway adapter · for neonates and
infants · 0.5 ml dead space volume
D
–
x
x
–
x
–
–
–
25
Sampling tube · for children and neonates · tube
length 2.5 m
D
–
x
x
–
x
–
–
–
25
Sampling tube · for adults · tube length 2.5 m
D
–
x
x
–
x
–
–
–
25
• NKD-Scottgas
Anaesthesia calibration gas · 1,000 ml
S
–
x
x
–
x
–
–
–
1
• 611358
Flow regulator · with pressure gauge and connection tube
R
–
x
x
–
x
–
–
–
1
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
35
(
D ye D e n s i t o g r a p h
)
Dye · page 37
Sensors · page 37
36
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
S
–
–
–
–
–
–
–
x
5
Finger sensor
R
–
–
–
–
–
–
–
x
1
Nose sensor
R
–
–
–
–
–
–
–
x
1
Injection detector
R
–
–
–
–
–
–
–
x
1
• P196
• TL-351P
TL-321P
Description
Indocyanin-green · 5 x 50 mg dye
• TL-301P
Article No.
• NKD-IC-GreenP
Supply Code No.
Disposable/Reusable/
Supplies
Dye · Sensors
DYE DENSITOGRAPH
Dye Densitograph
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1]
[2]
NKD-IC-GreenP
[1] TL-301P | [2] P196
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
TL-351P
37
(
Other Accessories
)
Power cable · page 39
Cleaning pen · page 39
Touch pen · page 39
Connection cable for external equipment · page 39
38
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
• NKD-L936 314839B
Power cable · cable length 2.5 m
R
x
x
x
x
x
x
x
x
1
Description
Article No.
Supply Code No.
Power Cable · Cleaning Pen · Touch Pen · Connection Cable for External Equipment
• Y011
404617
Cleaning pen for thermal head
R
x
x
x
x
x
x
x
x
1
• Y075
577297A
Touch pen for easy use of touch screen monitors · includes
cord and touch pen holder
R
x
x
x
x
x
x
x
–
1
• K974
515738
Connection cable for signal output of ECG and blood
pressure · cable length 5.0 m
–
x
x
–
–
–
–
–
1
R
OTHER ACCESSORIES
Other Accessories
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
NKD-L936
Y011
Y075
K974
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
39
(
Batteries
)
Batteries · page 41
Battery charger (external) · page 41
40
BATTERIES
Batteries
Description
Disposable/Reusable/
Supplies
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
• X062
YS-076P5
Battery pack · 12 V, 3700 mAh · nickel metal hydride
(Ni-MH) · rechargeable
R
x
–
–
–
–
–
–
–
1
• X060
NKB-101
Battery pack · 12 V, 1700 mAh · nickel cadmium
(Ni-Cd) · rechargeable
R
–
x
x
–
–
–
–
–
1
External battery charger for battery X060
(no illustration)
R
–
x
x
–
–
–
–
–
1
Supply Code No.
Article No.
Batteries · Battery Charger (external)
• SB-201VK
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
X062
X060
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
41
(
Recording Paper
)
Recording paper · page 43
42
BSM-2300 Lifescope i/L
BSM-4100 Lifescope P
BSM-5100 Lifescope A
BSM-9510 Lifescope M
BSM-9800 Lifescope S
OPV-1500 Lifescope N
WEP-4200/WEP-8400
DDG-2001
Quantity
S
x
x
x
x
x
–
x
x
1
• A810
Thermal recording paper · roll · 60 mm x 20 m
(each page 100 mm) · without grid
S
–
–
–
–
–
x
–
–
1
QW60-2
Description
Thermal recording paper · Z-fold book · 50 mm x 30 m
(each page 100 mm) · without grid
Article No.
• NKD-A723 FQW50-3-100
Supply Code No.
Disposable/Reusable/
Supplies
Recording Paper
RECORDING PAPER
Recording Paper
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
43
(
A c c e s s o r i e s f o r Te l e m e t r y Tr a n s m i t t e r
)
ECG electrode leads · page 45
ECG electrodes · page 46 to 47
Reusable SpO2 probes · page 48
Disposable SpO2 probes · page 49
Cuffs (reusable, latex-free) · page 50
Bags · page 50
44
ZB-810/ZB-811
ZB-820
ZB-823
ZB/ZS-910
ZB/ZS/ZM-920
ZB/ZS/ZM-930
ZS-940
Quantity
–
–
–
x1*
x1*
x
1
R
–
–
–
x1*
x1*
x
1
• K226
BR-019P Electrode lead for 3 electrodes · snap type · cable length 0.8 m
R
x
–
x
–
–
–
1
• K225
BR-018P Electrode lead for 3 electrodes · clip type · cable length 0.8 m
R
x
–
x
–
–
–
1
• K910A BR-913P Electrode lead for 3 electrodes · snap type · cable length 0.8 m
R
–
–
–
x
x
x
1
• K911
BR-903P Electrode lead for 3 electrodes · clip type · cable length 0.8 m
R
–
–
–
x
x
x
1
• K228
BR-021P Electrode lead for 5 electrodes · snap type · cable length 0.8 m
R
–
x
x
–
–
–
1
• K227
BR-020P Electrode lead for 5 electrodes · clip type · cable length 0.8 m
R
–
x
x
–
–
–
1
• K915
BR-916P Electrode lead for 6 electrodes · snap type · cable length 0.8 m
R
–
–
–
x
x
–
1
• K912
BR-906P Electrode lead for 6 electrodes · clip type · cable length 0.8 m
R
–
–
–
x
x
–
1
Description
R
• K907A BR-902P Electrode lead for 2 electrodes · clip type · cable length 0.8 m
Article No.
• K908A BR-912P Electrode lead for 2 electrodes · snap type · cable length 0.8 m
Supply Code No.
Disposable/Reusable/
Supplies
ECG Electrode Leads
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = not possible for ZM-9x0 series
[1]
[2]
[3]
[4]
[1]
[2]
[2]
[1] K908A | [2] K907A
[1]
[1]
ACCESSORIES FOR TELEMETRY TRANSMITTER
Accessories for Telemetry Transmitter
[1] K225 | [2] K226 | [3] K227 | [4] K228
[1] K910A | [2] K911
[2]
[1] K915 | [2] K912
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
45
Article No.
Description
Disposable/Reusable/
Supplies
ZB-810/ZB-811
ZB-820
ZB-823
ZB/ZS-910
ZB/ZS/ZM-920
ZB/ZS/ZM-930
ZS-940
Quantity
ECG Electrodes
• G217
D-90
Vitrode D · disposable ECG electrode · electrode material: Ag/AgCl ·
size: ca. 55 mm dia · applicable for X-ray, CT and MRT · adhesive by patent
pending electrode structure (2-dimensional elastic for tension) · very kind to
the skin · suitable for long term measurements (> 72 h) · wash-, shower- and
bath-steadily · for universal use
D
x
x
x
x
x
x
30 x 3
• G207
L-150X
Vitrode L · disposable ECG electrode · electrode material: Ag/AgCl ·
size: ca. 35 mm dia · applicable for X-ray, CT and MRT · strong adhesive ·
resistant against detachment by solvents · foam tape · for universal use
D
x
x
x
x
x
x
5 x 30
• G210C F-150S
Vitrode F · disposable ECG electrode (small) · electrode material: Ag/AgCl ·
size: ca.18 mm x 36 mm · cotton tape · electrically conductive adhesive gel ·
repeatedly positionable · very kind to the skin · very suitable for children ·
not for use in operating rooms
D
x
x
x
x
x
x
50 x 3
• G210D F-150M
Vitrode F · disposable ECG electrode (medium) · electrode material:
Ag/AgCl · size: ca. 25 mm x 45 mm · cotton tape · electrically conductive
adhesive gel · repeatedly positionable · very kind to the skin · not for use
in operating rooms
D
x
x
x
x
x
x
50 x 3
• G201
Vitrode Bs · disposable ECG electrode · electrode material: Ag/AgCl ·
D
size: ca. 47 mm x 47 mm · soft breathing cotton tape with an elastic quality for
tension · hydro gel for low electrode impedance and stable measurements
even on dry skin · for universal use
x
x
x
x
x
x
30 x 5
Supply Code No.
ACCESSORIES FOR TELEMETRY TRANSMITTER
Accessories for Telemetry Transmitter
Bs-150
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
46
G217
G207
G210D
G201
G210C
ECG Electrodes
ZB-810/ZB-811
ZB-820
ZB-823
ZB/ZS-910
ZB/ZS/ZM-920
ZB/ZS/ZM-930
ZS-940
Quantity
Disposable/Reusable/
Supplies
NKD-H34SG
Description
G250
Article No.
Supply Code No.
G204
• G204
C-150
Vitrode C · disposable ECG electrode · electrode material: Ag/AgCl ·
D
size: ca. 47 mm x 47 mm · soft breathing cotton tape with an elastic quality for
tension · hydro gel for low electrode impedance and stable measurements
even on dry skin · the electrode gel is nearly removed after removing the
electrode · for universal use
x
x
x
x
x
x
30 x 5
• G250
J-150
Vitrode J · disposable ECG electrode · electrode material: Ag/AgCl ·
D
size: ca. 40 mm dia · foam tape with excellent adhesive advantages even by
effects of sweat or solvents · hydro gel for low electrode impedance and stable
measurements even on dry skin · the electrode gel is nearly removed after
removing the electrode · for universal use
x
x
x
x
x
x
30 x 5
Disposable ECG electrode ARBO® · size: ca. 45 mm dia · applicable for X-ray,
CT and MRT · hydro gel · very strong adhesive · 72 h endurance test · showerand wash-steadily · with skin remover
x
x
x
x
x
x
30
• NKD-H34SG
D
ACCESSORIES FOR TELEMETRY TRANSMITTER
Accessories for Telemetry Transmitter
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
47
ZB-810/ZB-811
ZB-820
ZB-823
ZB/ZS-910
ZB/ZS/ZM-920
ZB/ZS/ZM-930
ZS-940
Quantity
Finger probe · for adults and children with a weight of more than 20 kg ·
cable length 1.6 m
R
–
–
–
–
x
1*
1
• P225F TL-201T
Finger probe BluPRO® series · for adults and children with a weight of
more than 20 kg · cable length 1.6 m
R
–
–
–
–
x
1*
1
• P225G TL-220T
Multi-site probe BluPRO® series · for adults and children with a weight of
more than 3 kg · cable length 1.6 m
R
–
–
–
–
x
1*
1
• P225H TL-201T
Finger probe BluPRO® series · same as P225F, but cable length 0.6 m
(illustration similar to P225F)
R
–
–
–
–
–
x
1
• P205A TL-260T
Multi-site Y probe · for neonates and infants (semi disposable) · cable
length 1.6 m
R
–
–
–
–
x
1*
5
• P256
Ear clip for multi-site Y probe P205A (no illustration)
R
–
–
–
–
x
1*
1
• P260A 6143-011854
Sponge attachment tape S for multi-site Y probe P205A
R
–
–
–
–
x
1*
24
• P260B 6143-011863
Sponge attachment tape L for multi-site Y probe P205A
R
–
–
–
–
x
1*
24
6143-012434
Description
• P224A TL-101T
Article No.
Disposable/Reusable/
Supplies
Reusable SpO2 Probes
Supply Code No.
ACCESSORIES FOR TELEMETRY TRANSMITTER
Accessories for Telemetry Transmitter
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = because of cable length, fit for limited use
P224A
48
P225F
P225G
P260A
P260B
P205A
Disposable SpO2 Probes
[1]
[1]
[2]
[2]
[3]
ZB-823
ZB/ZS-910
ZB/ZS/ZM-920
ZB/ZS/ZM-930
ZS-940
Quantity
D
–
–
–
–
x
1*
5
• P201B TL-252T
Disposable probe BluPRO® series for finger or toe · for children with a weight
between 3 kg and 40 kg · cable length 1.6 m
D
–
–
–
–
x
1*
5
• P201A TL-251T
Disposable probe BluPRO® series for finger or toe · for adults with a weight of
more than 30 kg · cable length 1.6 m
D
–
–
–
–
x
1*
5
• P229A TL-061S
Disposable probe · for adults and children with a weight between 15 kg and
50 kg (finger probe) and/or children with a weight between 3 kg and 15 kg
(toe probe) · cable length 0.8 m
D
–
–
–
–
x
1*
5
• P229B TL-062S
Disposable probe · same as P229A, but cable length 1.6 m
D
–
–
–
–
x
1*
5
• P228A TL-051S
Disposable probe · for adults with a weight more than 50 kg (finger probe)
D
and/or neonates with a weight less than 3 kg (foot probe) · cable length 0.8 m
–
–
–
–
x
1*
5
• P228B TL-052S
Disposable probe · same as P228A, but cable length 1.6 m
D
–
–
–
–
x
1*
5
• P259
COTTONY tape for fixing the disposable probes
R
–
–
–
–
x
x
20
340703
Description
Disposable probe BluPRO® series for foot · for infants with a weight of less
than 3 kg · cable length 1.6 m
Article No.
• P201C TL-253T
Supply Code No.
ZB-820
P259
ZB-810/ZB-811
[1] P228A | P228B | [2] P229A | P229B
Disposable/Reusable/
Supplies
[1] P201A | [2] P201B | [3] P201C
ACCESSORIES FOR TELEMETRY TRANSMITTER
Accessories for Telemetry Transmitter
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
[1*] = because of cable length, fit for limited use
Disposable accessories can be used only once. Do not use disposable accessories repeatedly!
49
ZB-810/ZB-811
ZB-820
ZB-823
ZB/ZS-910
ZB/ZS/ZM-920
ZB/ZS/ZM-930
ZS-940
Quantity
–
–
–
–
–
x
1
• S938C YP-944P Cuff for adults · width 15 cm · for circumference of 26–36 cm · latex-free ·
NK bayonet joint on connection hose (no illustration)
R
–
–
–
–
–
x
1
Description
R
Article No.
• S938B YP-943P Cuff for adults · width 13 cm · for circumference of 21–30 cm · latex-free ·
NK bayonet joint on connection hose (no illustration)
Supply Code No.
Disposable/Reusable/
Supplies
Cuffs (reusable, latex-free)
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
ZB-810/ZB-811
ZB-820
ZB-823
ZB/ZS-910
ZB/ZS/ZM-920
ZB/ZS/ZM-930
ZS-940
Quantity
Disposable transportation bag for telemetry transmitter · with belt
D
x
x
x
x
–
–
3
• NKD-Tasche
Transportation bag for telemetry transmitter · with belt (illustration similar as
NKD-Tasche1)
R
x
x
x
x
–
–
1
• NKD-Tasche1
Transportation bag for telemetry transmitter · with belt
R
–
–
–
–
x
–
1
• Y236
Shoulder strap (no illustration)
R
–
–
–
–
–
x
1
Description
• Y264E
Article No.
Disposable/Reusable/
Supplies
Bags
Supply Code No.
ACCESSORIES FOR TELEMETRY TRANSMITTER
Accessories for Telemetry Transmitter
[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies
Y264E
50
NKD-Tasche1
Warranty
General Warranty Regulations
NIHON KOHDEN offers a one-year warranty for their products against material
defects and functional breakdowns starting from the day of delivery.
Excluded from this warranty are consumable materials such as recorder paper,
ink and batteries. NIHON KOHDEN products in which a defect occurs during this
warranty period will be repaired or replaced by NIHON KOHDEN customer
services or will be repaired or replaced by the authorised specialist dealer, provided that the products were used in accordance with the instructions given in
the Operating Instructions.
No other persons or organisations are authorised to grant a warranty or enter
into obligations for our products. NIHON KOHDEN does not recognise any other
form of warranty, whether implicit or in writing.
The warranty claim expires as soon as servicing measures, technical modifications or other product changes are carried out by personnel not authorised by
NIHON KOHDEN or without the explicit agreement of NIHON KOHDEN.
Furthermore, the warranty claim expires in the event of unauthorised opening
of the device, of re-installation or repair by personnel not authorised by
NIHON KOHDEN as well as in the event of removal of the rating plates, in the
event of damage resulting from negligence, the use of force, or in the event of
damage caused by fire, lightning, water, vandalism, force majeure or improper
installation or use.
Warranty for reusable SpO2 sensors
The warranty period granted by NIHON KOHDEN for SpO2 sensor materials and
workmanship ends 6 months after opening the packaging, but by the latest 12
months after delivery. NIHON KOHDEN or its authorised specialist dealer will
repair or replace defective sensors provided that they have been used in
accordance with the Instructions for Use.
Please also observe our General Sales, Delivery and Payment Conditions!
Despite the meticulous care taken in compiling the information for this
Catalogue of Accessories, we cannot unfortunately rule out errors or
mistakes!
51
Remarks
Customer Number:
(By quoting your customer number you will particularly help us to expedite processing of your order.)
Device
52
Type Designation
Serial Number
Index as per Supply Code No.
Supply Code No. Page
611358
35
6124-039432
10
A810
43
G201
11, 46
G204
11, 47
G207
11, 46
G210C
11, 46
G210D
11, 46
G217
11, 46
G250
12, 47
G271A
12
G271K
12
G272A
12
G272B
12
G272C
12
G300A
13
K225
45
K226
45
K227
45
K228
45
K901
10
K907A
45
K908A
45
K910A
10, 45
K911
10, 45
K912
10, 45
K915
10, 45
K921
10
K922
10
K931
15
K941
34
K951
25
K952
25
K961
19
K962
27
K974
39
K981
30
K982
31
K984
29
L060
10
L311
15
L901
25
NKD-006342
32
NKD-A723
43
NKD-CO2Gas
31
NKD-H34SG
13, 47
NKD-IC-GreenP
37
NKD-L936
39
NKD-P240A
19
NKD-P241A
19
Supply Code No. Page
NKD-P242A
19
NKD-P249
19
NKD-P249S
19
NKD-P249M
19
NKD-Scottgas
35
NKD-SP4045
27
NKD-SP4500
27
NKD-SP4572
27
NKD-SP5045
27
NKD-SP5107H
27
NKD-SP5107H-IS
27
NKD-Tasche
50
NKD-Tasche1
50
NKD-V915A
34
NKD-V915B
34
NKD-V916A
34
NKD-V916B
35
NKD-V917A
35
NKD-V917B
35
NKD-Ventil
31
NKD-XS04620
32
NKD-XS04624
32
P196
37
P201A
17, 49
P201B
17, 49
P201C
17, 49
P205A
16, 48
P224A
16, 48
P225F
16, 48
P225G
16, 48
P225H
48
P228A
17, 49
P228B
17, 49
P229A
17, 49
P229B
17, 49
P256
16, 48
P259
17, 49
P260A
16, 48
P260B
16, 48
P901
13
P902
13
P903
30
P905
30
P907
29
P911
34
P921
30
P922A
30
P923
29
R801
30
R802
31
Supply Code No. Page
R803
31
S901
21
S902
21
S903
21
S904
21
S905
21
S929A
21
S929B
21
S930A
21
S930B
21
S938B
50
S938C
50
S943A
22
S943B
22
S943C
22
S944B
22
S944C
22
S944D
22
SB-201VK
41
SP-4035-1
27
TL-301P
37
TL-351P
37
V901
32
V903E
32, 35
V903F
32, 35
V907A
32
V907B
32
V907C
32
V911
13
V912
34
V921
29
V922
29
V923
29
X060
41
X062
41
Y011
39
Y075
39
Y236
50
Y264E
50
YP-910P
23
YP-912P
23
YP-913P
23
YP-914P
23
YP-915P
23
YP-916P
23
YP-920P
23
YP-921P
23
YP-922P
23
YP-923P
23
53
Index as per Article No.
Article No.
074705
110774
314839B
340703
404617
515738
577297A
613712
613721
613739
613748
613766
613775
6143-011854
6143-011863
6143-012434
618877
680000
680006
680077
680078
680178
684062
ASR618
ASR618a
BJ-900P
BR-018P
BR-019P
BR-020P
BR-021P
BR-902P
BR-903P
BR-906P
BR-912P
BR-913P
BR-916P
Bs-150
C-150
D-90
F-150M
F-150S
FQW50-3-100
J-150
JC-103T
JC-900P
JC-906P
JG-900P
JG-920P
JG-950P
JL-302T
54
Page
34
34
39
17, 49
39
39
39
34
34
34
35
35
35
16, 48
16, 48
16, 48
32, 35
27
27
27
27
27
27
19
19
10
45
45
45
45
45
10, 45
10, 45
45
10, 45
10, 45
11, 46
11, 47
11, 46
11, 46
11, 46
43
12, 47
10
10
10
30
29
31
15
Article No.
JL-900P
JO-900P
JP-900P
JP-910P
JP-920P
JT-900P
JT-950P
L-150X
N-03IS3
NKB-101
QW60-2
TG-101T
TG-201T
TG-900P
TG-920P
TG-921T
TG-950P
TL-051S
TL-052S
TL-061S
TL-062S
TL-101T
TL-201T
TL-220T
TL-251T
TL-252T
TL-253T
TL-260T
TL-321P
TR-900P
TR-910P
V-040M4
V-060M6
V-090M3
V-120S3
V-120SK
YG-001P
YG-101T
YG-120T
YG-121T
YG-122T
YG-201T
YG-202T
YG-904P
YG-912P
YG-913P
YG-914P
YG-920P
YN-100T
YN-101T
Page
15
34
25
25
25
19
27
11, 46
13
41
43
30
30
30
29
29
30
17, 49
17, 49
17, 49
17, 49
16, 48
16, 48
16, 48
17, 49
17, 49
17, 49
16, 48
37
13
13
12
12
12
12
12
13
30
29
29
29
31
31
32, 35
32
32
32
32
21
21
Article No.
YN-120T
YN-121T
YN-900P
YN-901P
YN-920P
YN-921P
YN-990P
YP-943P
YP-944P
YP-960T
YP-961T
YP-962T
YP-963T
YP-964T
YP-965T
YS-076P5
YSI-401
YSI-402
YSI-409A
Page
21
21
21
21
21
21
21
50
50
22
22
22
22
22
22
41
19
19
19
CARDIOLOGY
PATIENT MONITORING
first art // Gießen
NEUROLOGY
Vol. 1
NIHON KOHDEN EUROPE GmbH
Raiffeisenstraße 10
D-61191 Rosbach (Germany)
Telefax:
+ 49 (0) 60 03 / 8 27-599
E-Mail:
[email protected]
www.nihonkohden.com
Dealer
PMS-Z-e-01/05
Telephone: + 49 (0) 60 03 / 8 27-0