3200 Cours Le Corbusier, Boisbriand, Quebec J7G 3E8 Tel.: (450
Transcription
3200 Cours Le Corbusier, Boisbriand, Quebec J7G 3E8 Tel.: (450
3200 Cours Le Corbusier, Boisbriand, Quebec J7G 3E8 Tel.: (450) 939-0799 – Fax: (450) 939-2115 www.APG-Neuros.com Company Overview Leader of Turbo Machinery - Development Creating Clear and Clean Environment Neuros Co. Daejeon (South Korea) Company Overview APG-Neuros Name: APGN Inc. Business: Design, Manufacturing, Service, Sales Product: Turbo machinery and Waste Water Control System Address: 3200, Cours Le Corbusier, Boisbriand, QC, Canada J7G 3E8 Contact: Tel.: +1-450-939-0799 – Fax: +1-450-939-2115 Toll Free: 1-866-592-9482 Homepage: www.APG-Neuros.com Plattsburgh NY, USA Field of Business Turbo Blower, Turbo Compressor, Turbo Refrigerator Turbo Power Air Conditioning/ Refrigeration Micro Gas Turbine Energy/ Environment Gas Turbine Engine for UAV Field of Business / Technology Aero Engines CybirdTM MAV, Automatic Water Sampler Robot / Control Development Projects • • • • • • • Turbo pump design for rocket launch vehicle and turbo compressor Gas Turbine Engine maintenance and performance simulation S/W Turbo Charger performance test for ships Propulsion system for UAV Test equipment for turbojet and turboprop engines Motor and controller for Smart UAV Power System Rotor spin test Technology High Efficiency Centrifugal / Axial Flow Compressor Design Radial / Axial Flow Turbine Design Oil-free Bump Foil Air Bearings High Efficiency Permanent Magnet Synchronous Motor Design and Manufacturing High Speed Flexible Coupling High-precision Flux Measurement / Venturi / Orifice / Nozzle / Belmouth Low Emission Diesel / Natural Gas Combuster Air Cycle Turbo Refrigeration Precision Electronic Control (Flux Control / Velocity Control) Gas Ejector (Jet Pump) Design and Integration of Complete Aeration Control System Features and Benefits Turbo Power Introduction The Neuros Turbo Blower is a “Plug and Play” product that offers high-efficiency in a compact size made possible by combining the latest design technologies of Aeronautic Compressor, Bump Foil Air Bearing and High Speed Permanent Magnet Synchronous Motors (PMSM) with built in Variable Speed Drive and Programmable Logic Controller. Neuros Turbo Blowers can attain flow rates up to 8500 CFM and a discharge pressure up to 42 PSIG with motor horsepower range from 30 to 300 HP. We also offer the “Dual Core” models NX400 (400 HP) and NX600 (600 HP) models that combine two cores within the same enclosure unit to provide flow rates range between 3000 and 17,000 SCFM while maintaining a small footprint compared to conventional technologies with similar flow rates. Features and Benefits 1 Energy Efficiency, operating cost savings • The Neuros Turbo Blower is the most efficient in its class through the use of advanced technologies in aerodynamics, high speed permanent magnet motors and Bump-Foil air bearings along with intelligent use of drive & control technologies. • Operating cost savings up to 40% are possible when compared to conventional blower, drive and control technologies. [NX Series Operating Cost] 2 Low Noise, Low Vibration • Neuros’ clever enclosure design effectively controls sound propagation and reduces noise levels to 80dB(A). • Non-contact air bearing having low vibration eliminates need for heavy foundations. • Patent technology of Noise Trapping System. 3 Reliable, Easy to Install, Outdoor Application • Extensive testing has proved out the Neuros product reliability in hot environments, vibration, air bearing endurance and impeller spin tests. • Blower packages are significantly more compact than conventional technologies and simpler to install. • Outdoor installation package is available. 4 Maintenance • Regular maintenance involves periodic cleaning or replacing of inlet air filter only, as required. • Reading operating parameters from user-friendly touchscreen control panel. Turbo Power Features and Benefits 5 High Efficiency Impeller Design and Manufacturing 6 Oil-free, Non-contact Air Bearing 7 Permanent Magnet Synchronous Motor (PMSM) 8 Cooling 9 Alternate Arrangement Option 10 • Ten years of experience designing impellers in aerospace industry. • Designed with in-house software and 3-D Computational Fluid Dynamics. • 5-axis machining of solid forging provides higher integrity, tighter manufacturing tolerances, larger diameters and lower speeds all resulting in higher efficiency. • Production technology permits design of impeller with both axial and radial compression. • No lubricating oil or associated maintenance. • No contact - Less noise and vibration from rotor during operation. • 25,000 cycle start-stop endurance test, equivalent to more than twenty years life time in typical operation. • Patent (air Foil Bearing): No. 10-0604132. • • • • Very High Efficiency and power factor. Maintains efficiency and power factor in partial load conditions. Driven by sinusoidal PWM algorithm lowers motor heat rejection and minimizes cooling requirements. High precision motor speed control. • • • • Blower core and motor cooled with blower inlet air. VFD and control systems cooled by inlet air. No heat rejection to blower room. Integrated Glycol cooling system in NX200 and NX300 models for higher performance and durability. No external water supply required. • No auxiliary exhaust systems. (No additional power consumption). • Patent (Efficient Motor Cooling): No. 10-0572849. • The specially tuned controls and variable frequency drive integrated in our packagd can be built into a separate cabinet and located up to 600 feet away from mechanical section for high ambient temperature or toxic gas environments. Control, Monitoring, Diagnostics • Integrated Programmable Logic Controller (PLC) makes it possible to run the blower in constant pressure, flow or DO control mode. • PLC options: Allen Bradley, CIMON, Siemens, GE and Modicon available to suit customer control system. • Communication protocols include Ethernet, Profibus, Modbus and hard wiring. • User friendly control, monitoring and diagnostics on touch screen panel to view all process paramaters and blower conditions. Turbo Power Oil-free, High-efficiency Turbo Blower Performance Characteristics of NX Series Standard Air Flow Rate of NX Series Turbo Blower Performance Characteristics of NX Series *Air Flow at 68OF, 14.7 PSI, 65% RH (20OC, 1 atm, 65% RH) Turbo Power APG–Neuros, Clean Environment and Energy Saving Oriented Company Model Selection Model Selection NX100, NX150 NX30, NX50, NX75 NX30-C100 NX50-C100 NX30-C080 NX50-C080 NX75-C080 NX50-C070 NX30-C070 NX30-C060 NX75-C070 NX50-C060 NX50-C050 NX75-C060 NX75-C050 NX200, NX300 Turbo Power Technical Data Technical Data / Material of Construction Design pressure range Design suction flow rate Reference design condition Turndown ratio Operating speed range Motor kW (HP) rating Casing design pressure Casing design temperature Vibration Inlet configuration Impeller Air Seals Discharge configuration Lubrication Bearings Motor Motor starter Input power Noise level Control panel Control algorithm Network communicatioin Enclosure cooling Motor/ VFD cooling 4.4-14.5 psig (0.3 - 1.0 bar) 670-7293 SCFM at 8.5 psi (0.59 bar) 68F, 14.7 psia, 65% RH 100-45 % 17,000 ~ 47,000 rpm 22/37/55/75/112/150/223 kW (30-300 HP) 284 psig (19.6 bar) – Scroll 300oC (572 F) – Scroll <0.039 in/Sec Louver or Flange Single Stage / Centrifugal Labyrinth Vertical/Horizontal ANSI 150 lb Flange Not required Bump Foil Air Bearing Permanent Magnet Synchronous Motor type Inverter type – Variable frequency drive 380-480V, 3 Ø, 50/60 Hz 75 – 80 dB(A) PLC & Touch Screen (Allen Bradley, CIMON, Siemens, Modicon) Auto Speed/Flow/Pressure Mode/DO Ethernet IP/ Modbus/ Profibus/ Hard Wiring Filtered Air cooled Air (50-150 HP)/ Water (200-300 HP) Material of Construction Blower casing Impeller Diffuser vanes Shaft Air bearings Motor Case Electrical enclosure Blower enclosure Bloser enclosure skid Enclosure finish ASTM 356.0 (Al Alloy)/ Cast Iron Forged aluminum alloy (Al 7075) Vaneless Type Ti Alloy (Ti-6Al-04V) Ni-base Super Alloy (X-750) ASTM 356.0 (Al Alloy) Powder coated steel Powder coated steel with sound dampening material Structural steel construction with fork lift access ports Powder coating Turbo Power Benefits Benefits / Typical Applications Energy savings up to 40% compared to conventional technologies. Maintenance costs savings with minimum maintenance. Savings Significant space and installation cost savings with compact blower package design. Product is recognized by energy efficiency and accreditation agencies for energy credit and rebates. Environment Low noise and vibration for better working environment. Lower emissions, power savings, no oil to change, no disposable items, uses washable and re-usable air filters. Typical Applications Aeration for municipal industrial waste water treatment. Pneumatic conveying of powders and materials in cement, wood chips, coal, limestone and plastic industries. Pneumatic conveying and blending for petrochemical industry. Oxidization in power plant desulfurization process. Cooling air for power plant generators. Combustion Air, in power generation plants. Air knife application in steel industry. Atomization. Neuros Turbo Blower is on a different level Standard VFD Separated Unit: inch NX50-NX100 NX150 NX200 NX300 Unit: inch NX50-NX100 NX150 NX200 NX300 A 61 69 83 83 B 30 30 39 55 C 53 53 65 80 A 61 55 61 65 B 30 30 35 39 C 37 42 61 68 Dimensions based on standard configuration, subject to change without notice. VFD cabinet dimensions can be changed per application requirements. VFD cabinet can be installed up to 650 feet from blower. Dimensions do not include mounting feet height. 3200 Cours Le Corbusier, Boisbriand, Quebec J7G 3E8 Tel.: (450) 939-0799 – Fax: (450) 939-2115 www.APG-Neuros.com