V-Series - Carling Technologies
Transcription
V-Series - Carling Technologies
V-Series Contura Switches Product Highlights: Maximum sealing protection with dual seals around lamps and rocker stem, certified to IP66 & IP68. Optional panel seals for additional protection. Silver plated butt contact mechanism provides 50 to 100 thousand electrical cycles and a variety of different electrical ratings. Roller pin mechanism does not require lubricants and allows the switch to withstand extreme temperatures. The switch base accommodates up to 10 terminals and a large variety of switch and lighting circuits. The multi-step mounting wings provide a secure fit for panel thicknesses of 0.032” thru 0.250” in an industry standard 0.830” x 1.450” mounting hole. The switch connector allows the user to preload FQC terminals for easy assembly to switch base. Numerous choices of removable rockers allow for style change without having to retest or re-qualify the switch base. Illumination options are endless with bar, oval, and square lenses available with choices of incandescent, neon and a wide variety of LEDs including superbrite, megabrite, flashing and bicolor lighting. Available with a variety of complimentary mounting panels, hole plugs, illuminated indicators and boots to accommodate most any design need. Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: (860) 793-9281 • Fax: (860) 793-9231 www.carlingtech.com CONTURA III CONTURA V CONTURA II CONTURA VII Carling Technologies’ fully sealed V-Series Contura switches are well known for their cutting edge design, high quality, maximum performance and unmatched reliability. These switches are a staple in the marine and transportation industries and have passed a range of environmental, corrosion, temperature, vibration, shock and sealing tests including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC 60529 and BS 5490 among others, making them one of the most rugged and reliable switches ever manufactured. 2 | V-Series Contura Sealed Rocker Switches V-Series Switch DESIGN FEATURES INTERCHANGEABLE ACTUATORS Panel redesign is a snap with our wide range of rocker styles. Achieve maximum design variety with minimum inventory. Simply swap rockers to create an entirely new look for your panel. OPTIONAL PANEL SEAL Prevents water/dust ingress behind panel. DUAL SEAL PROTECTION Seals out water, dust, debris, and enables switch certification to IP66/IP68 for front panel components. MULTIPLE LIGHTING OPTIONS In addition to Incandescent lamps, our LED illumination is offered in a wide array of light intensities, colors, as well as dual level, tri-color, and flashing options. CLEAN CONNECTIONS Options for both eight and ten terminal base styles with AMP & Packard compatible connectors affords myriad circuit options while providing ease of assembly. BRASS ROLLER PIN Robust mechanism eliminates the need for lubricants. Enables switch to withstand -40°C to +85°C temperatures. SILVER PLATED BUTT CONTACT MECHANISM Providing 50k to 100k electrical cycles and a variety of different electrical ratings. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com V-Series Contura Sealed Rocker Switches & Illuminated Plug | 3 Contura II & III Contura X The Contura II & III actuators are constructed of thermoplastic polycarbonate and are offered with a hard nylon overlay or a “soft-touch” elastomer overlay. These models incorporate aesthetic designs on the top and bottom of the rocker featuring two rows of raised “bumps” on the Contura II and three “indented” lines on the Contura III. The raised bracket/bezel on the Contura X helps prevent inadvertent actuation of the rocker, as well as preventing debris from being trapped under the actuator. This curved rocker style is available with a variety of lenses and legends. Contura IV Contura XI The Contura IV’s “Shape to create a Shape” actuator works with the curves, contours & advanced styling of the latest panel designs, flowing with these advanced curves & radii. This actuator style fits on the Contura flush bracket/ bezel. Contura V The raised bracket/bezel on the Contura XI helps prevent inadvertent actuation of the rocker, as well as preventing debris from being trapped under the actuator. This convex style rocker is available with a wide variety of lenses and legends. Contura XII The symmetrically curved Contura V actuator provides the perfect complement to the Contura IV’s “Shape to create a Shape” design concept. With its flush style mounting bracket, Contura V can be mounted in between two Contura IV’s, by itself, or in groups. The Contura XII version features a paddle style actuator with the raised bracket/bezel of Contura X and XI. The contoured handle design provides intuitive recognition and ease of operation and is available with all Contura X and XI lens and legend offerings. Contura VI (WAVE) Contura XIV The Contura VI WAVE sealed rocker switches, when used in a row, create an uniquely appealing “wave” design on your panel. A variety of colors and finishes are available for both rocker and wave insert. Contura VI features bar and oval lenses. Contura VII Contura VII featuring gently curved corners and edges assuring compatibility with most any panel design. Intuitive feel is maximized by the use of 2 embossed circular pads located at opposite ends of the rocker. Any combination of Bar or Oval style lenses can be located in the pads providing a truly unique look, exclusive to Contura VII. The Contura XIV represents a sleek new crossover rocker design which should appeal to Trucks, Buses and Heavy Vehicles as well as the Marine Industry. Intuitive feel is provided by recessed ridges along with a Center Groove which effectively defines the boundary between top and bottom switch functions. V-Series Illuminated Indicators & Accessories Alert operator of systems functions or malfunctions, are offered with removable/replaceable lamps in Contura II, II, V or X styles. Accessories include connectors, mounting panels, hole plugs, panel seals, and actuator removal tools. Refer to accessories page for full details Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 4 | V–Series Contura Sealed Rocker Switches - General Specifications Electrical Contact Rating .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 1/2 HP 125-250VAC 20 amps, 4-14VDC 15 amps, 15-28VDC 10A, 14VT 6A, 125VAC L Dielectric Strength 1500 Volts RMS Insulation Resistance 50 Megohms Initial Contact Resistance 10 milliohms max. @ 4VDC Life 50,000- 100,000 cycles circuit dependent Contacts Silver alloy, silver tin-oxide, fine silver Terminals Brass or copper/silver plate 1/4” (6.3mm) Quick Connect terminations standard. Solder lug, Wire Lead Mechanical Endurance Physical 150,000 cycles minimum circuit dependent Lighted Incandescent - rated 10,000 hours Neon - rated 25,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC) Seals Internal Optional external gasket panel seal Base Polyester blend rated to 125°C with a UL flammability rating of 94V0. Contura II,III,IV,V, Hard Surface: Basic actuator VI, VII Actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay. Soft Surface: Basic actuator structure molded of thermoplastic polycarbonate with an elastomer overlay. Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C Lens Polycarbonate rated at 100°C Contura XIV Polycarbonate lens/subrocker with ABS shell Actuator Travel (Angular Displacement) 2 position 3 positions 18° 9° from center Mounting Specifications .830[21.08] Panel Thickness Range Gaskets Acceptable Panel Thickness 0 .030 to .250 (.76mm to 6.35mm) TEST CUT 1.450[36.83] HOLE IN 1 .030 to .109 & .147 to .157 ACTUAL MATERIAL (.76 to 2.77mm & 3.73 to 3.98mm) Recommended: No gasket with panel SWITCH thickness of .032, .062, .093, .125,.187 or .250 MOUNTING HOLE Agency Certifications Environmental Sealing Sealed version: IP68, in accordance with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual switch only, and signifies protection against dust and the prolonged effects of immersion under pressure. The standard test for immersion under pressure requires submersion under one meter of water for 30 min. The V-Series switch has exceeded these parameters, having been actuated and illuminated during submersion. Corrosion Mixed Flowing Gas (MFG) Class III 3 year accelerated exposure per ASTM B-827, B-845 Silver and gold contacts Operating Temp. -40°C to + 85°C Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test, pre and post test contact resistance. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 Hz ±10 G’s peak Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10μ seconds chatter. Shock Per Mil-Std 202F, Method 213B, Test Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre and post test contact resistance. Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 96 Hrs. Sealed version only. Dust Per Mil-Std 810C, Method 510.2 Air Velocity 300 ±200 Feet/Min, Test Duration 16 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test Cond. A, -55°C to 85°C. Test criteria pre and post test contact resistance Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance Ignition Protection All Contura switches with sealed construction meet the requirements of UL1500/ISO8846 for ignition protection, in addition to conformance with EC directive 94/25/EC for marine products. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com V–Series Contura II, III, & IV | 5 Dimensional Specifications: in. [mm] Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 6 | V-Series Contura V, VI & VII Dimensional Specifications: in. [mm] CONTURA V CONTURA V SHOWN WITH BAR LENS SHOWN WITH LOW PROFILE LOCK 1.922[48.56] 1.922[48.56] 1.079 [27.40] 1.550 [39.37] .505 [12.83] .250 [6.35] X .031 [.78] .250 [6.35] X .031 [.78] .820 [20.83] .960 [24.38] 8 TERMINAL BASE W/O BARRIERS 7 8 1 2 5 2 5 3 6 3 6 1 SWITCH SHOWN WITH VCH CONNECTOR 8 TERMINAL BOTTOM VIEW TERMINAL ARRANGEMENT 8 TERMINAL BASE 10 .250 [6.35] .031 [.78] .820 [20.83] 10 TERMINAL BASE W/O BARRIERS 4 8 2.029 [51.53] 0.985 [25.02] .960 [24.38] .960 [24.38] 8 TERMINAL BASE W/BARRIERS 10 TERMINAL BASE W/O BARRIERS 1.000 [25.40] .250 [6.35] X .031 [.78] .390 [9.90] 1.922[48.82] 10 TERMINAL BASE W/BARRIER AND LAMP TERMINAL 1.020 [25.91] .505 [12.83] SHOWN WITH LARGE LENS AND BAR LENS 1.126 8 TERMINAL BASE W/O BARRIERS 1.020 [25.91] CONTURA VII SHOWN WITH OVAL LENS 1.950[49.53] .080[2.03] 1.479 [37.57] 8 TERMINAL BASE W/BARRIERS CONTURA VI .820 [20.83] .960 [24.38] 10 TERMINAL BASE W/O BARRIERS 7 4 9 BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL V-Series Contura X, XI, XII & XIV | 7 Dimensional Specifications: in. [mm] CONTURA X STYLE CONTURA XI STYLE SHOWN WITH RAISED BRACKET .350 [8.89] SHOWN WITH PADDLE ACTUATOR CONTURA XIV STYLE SHOWN WITH LARGE LENS 1.928 [48.97] .667 [16.94] 1.910[48.51] CONTURA XII STYLE SHOWN WITH RAISED BRACKET AND TWO SQUARE LENSES 1.910[48.51] .426[10.82] .350[8.89] 1.586[40.28] .573 [14.56] 1.305[33.15] 1.506[38.25] 1.370[34.79] 1.370[34.79] 1.370[34.79] 8 TERMINAL BASE W/BARRIERS 10 TERMINAL BASE W/O BARRIERS .960[24.38] 8 TERMINAL BASE W/O BARRIERS .960[24.38] .960[24.38] .780[19.81] 10 TERMINAL BASE W/O BARRIERS .970 [24.64] .780[19.81] .780[19.81] .250[6.35] X .031[.78] .390[9.90] .390[9.90] .820[20.82] 8 TERMINAL BASE W/BARRIERS SWITCH SHOWN WITH VCH CONNECTOR 8 TERMINAL .390[9.90] .820[20.82] .820[20.82] 10 TERMINAL BASE W/BARRIERS 10 TERMINAL BASE W/O BARRIERS 8 1 7 4 8 7 1 4 2 5 2 5 3 6 3 6 BOTTOM VIEW TERMINAL ARRANGEMENT 8 TERMINAL BASE 10 .820 [20.83] 9 BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE SWITCHES SHOWN WITH VC1 CONNECTOR 10 TERMINAL Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com .960 [24.38] 8 | V-Series Contura II to XIV - Circuit Diagram CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM 3 1 3 2 3 5 3 3 3 1 2 5 3 4 6 2 2 1 3 4 2 6 4 5 6 5 SYMBOL LEGEND 2 5 3 4 DEFINITION DESIGNATES TERMINALS AND CONTACTS DESIGNATES LAMP LOCATION DESIGNATES MAINTAINED CIRCUITS DESIGNATES OTHER POSITION H 2 5 3 2 SYM. 3 8 6 6 G 1 3 1 6 3 3 2 1 S 2 7 6 5 2 F 1 5 2 5 3 1 2 6 R 2 6 4 3 5 E 3 6 M D 1 4 5 3 1 6 2 5 3 L 2 3 5 2 5 C 1 1 6 2 4 6 K 2 3 4 2 B 1 3 J 2 3 CIRCUIT DIAGRAM 1 6 A 2 CIRCUIT DESIGNATES MOMENTARY CIRCUITS DESIGNATES TWO POSITION CONNECTION 2 5 DESIGNATES EXTERNAL JUMPER PROVIDED BY CUSTOMER Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com V-Series Contura II to XIV - Circuit Diagram | 9 LAMP CIRCUIT CIRCUIT DIAGRAM LAMP CIRCUIT +8 +8 A/1 F/6 1 G/7 2 M/R 2 J/8 +1 +3 -4 SPECIAL #3 +6 1 2 N/T +8 -6 2 1 SPECIAL #4 1 +3 2 -7 +3 +6 1 -7 2 -7 -8 2 +1 +3 -4 P/V 2 -6 1 2 -7 +8 +1 +3 1 2 K/W CIRCUIT DIAGRAM 1 U/Y 2 (-)7 CIRCUIT DIAGRAM 3 1 +6 1 -7 3 17 18 10(-) J1 1 1 2 5 2 3 14 3 14 5 CIRCUIT DIAGRAM CIRCUIT CIRCUIT 10(-) J5 J5 1 3 5 1 3 5 3 1 6 16 6 16 JK 8 17 18 10(-) SYMBOL LEGEND SYM. SYMBOL LEGENDDEFINITION 1 1 J4 5 5 3 14 15 12 8 J4 2 3 14 15 12 3 14 JK 17 18 10(-) 3 11 13 1311 1 1 5 3 14 JJ 17 18 10(-) 5 NOTE: J circuits are available for all non-locking V-Series styles. Consult factory for p /n details. 6 11 13 13 11 8 J3 3 6 3 14 JJ 1 2 3 14 5 8 17 18 10(-) 5 -9 8 J3 2 -7 8 5 1 5 2 JA 1 J2 1 JA 17 18 10(-) J2 +10 CIRCUIT DIAGRAM 13 11 2 +8 CIRCUIT DIAGRAM 11 13 17 18 2 2 17 18 10(-) CIRCUIT 17 18 3 2 8 8 CIRCUIT CIRCUIT DIAGRAM 10(-) 1 17 18 10(-) J1 2 2 -7 1 +6 1 +8 -6 +3 2 +1 +3 1 SPECIAL #1 +3 H/Z -7 13 11 +3 1 +8 C/3 11 13 L/9 CIRCUIT DIAGRAM -6 -7 +3 CIRCUIT +3 LAMP CIRCUIT -7 1 -7 CIRCUIT -6 2 +8 1 E/5 CIRCUIT DIAGRAM -7 +3 D/4 +3 1 -7 B/2 LAMP CIRCUIT CIRCUIT DIAGRAM SYM. CIRCUIT DESIGNATES TERMINALS AND CONTACTS DEFINITION DESIGNATES LAMP LOCATION DESIGNATES TERMINALS AND CONTACTS DESIGNATES LAMP LOCATION JA,JJ,JK J1,J3,J4,J5 J2 CONNECTOR PART # JC1-01 JC2-01 JC3-01 DESIGNATES TWO POSITION CIRCUIT Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 10 | V-Series Contura II & III Sealed Rocker Switches - Ordering Scheme V 1 D A B T 0 B 1 Series 2 Circuit 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp A R B 00 8 Bracket 9 Actuator Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 0 00 13 14 Legend Actuator Orientation Lens Legend No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No SealB One SealC 5 ILLUMINATION 3,6 Actuator orientation above terminals: 1,4 10 LENS 0 - No Actuator Z - No Lens ClearWhite Amber Green 1 6 8 G 2 7 C H 3 8 D J 4 9 E K 5 A F L .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. Gray G H 0 No Actuator A, B Contura II C, D Contura III 3 RATING 4 TERMINATION/BASE STYLE White W Y 9 ACTUATOR 3 1 B C D E F M N 12 Legend Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT 11 Color 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) 1 SERIES V 10 Lens Red M N P R S Blue T U V W Y Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR COLOR1 AND TEXTURE Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) 0 - No Actuator BlackGray Red White Soft Surface BGRW Hard Surface CHSY 12 ACTUATOR LENS OR BODY LEGENDS2 11ON 12 OFF 13 I 14O OFF ONO I 15 O O 16 O O F N N F FF 17 O I 18 I O For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Body legends not available on Soft surface actuators; White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. 4 Contura II available with two square lenses. Consult factory for details. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com V-Series Contura II & III Locking Sealed Rocker Switches - Ordering Scheme | 11 V 1 D A S W 0 B 1 Series 2 Circuit 4 5 6 Termination Illumination Lock 3 Rating 7 Lamp 1 SERIES V Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 11 Function 0 12 Legend 13 Legend Orientation 3 RATING .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No SealB One SealC White W Y Gray G H 9 HARD SURFACE ACTUATOR1 Contura II BlackGray Red White A BGH Contura III C DEF 3,6 Actuator orientation above terminals: 1,4 10 LENS Z - No Lens ClearWhite Amber Green Red Blue 3 8 D J P V 4 1 B C D E F M N 10 Lens Lamp above terminals 3 & 6 end of switch Position: 9 Actuator 7 LAMP 2 CIRCUIT A Z E 00 8 Bracket Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR LOCK FUNCTION AND COLOR1 Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY MR 1 UP 3 (+) 6 (–) 6 LOCK Lock above terminals 1 & 4 end of switch. Wlock Lock Color Match Actuator Black White Red Safety Orange Up Down Up & Down Center3 A HR1 BJ S2 CKT 3 DL V4 E M W5 12 ACTUATOR LENS OR BODY LEGEND2 00 - No Legend 21 22 OFF ON 25 O F F 23 26 O N O 27 O 24 I 28 I For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 21-28 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 ORIENTATION 1 ORIENTATION 4 AZC45-1 45 ORIENTATION 2 AZC45-2 45 Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See V-Series Switch Accessories page. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com ORIENTATION 3 12 | V-Series Contura IV Sealed Rocker Switches - Ordering Scheme V 1 D A B T 0 B 1 Series 2 Circuit 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp E P C 00 8 Bracket 9 Actuator Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 13 14 Legend Actuator Orientation Lens Legend No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 2 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No SealB One SealC 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING Gray G H 1,4 Actuator orientation above terminals: 3,6 No Actuator Contura IV, left orientation Contura IV, left orientation, laser etched Contura IV, right orientation Contura IV, right orientation, laser etched 10 LENS 0 - No Actuator Z - No Lens ClearWhite Amber Green 1 6 8 G 2 7 C H 3 8 D J 4 9 E K 5 A F L .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE White W Y 9 ACTUATOR 0 E T F R 3 RATING4 1 B C D E F M N 0 00 12 Legend Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Position: 11 Color 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) 1 SERIES V 10 Lens Red M N P R S Blue T U V W Y EF Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) 11 ACTUATOR COLOR1,5,6 No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E 12 ACTUATOR LENS OR BODY LEGENDS2 11ON 12 OFF 13 I 14O OFF ONO I 15 O O 16 O O F N N F FF 17 O I 18 I O For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 ORIENTATION 1 ORIENTATION 4 E8C45-100 E3C70-200 F8C45-100 F3C70-200 ORIENTATION 2 E8C45-300 F8C45-300 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Gloss brow is on left side of E actuator and right side of F actuator. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Laser etched rocker only available with lens code Z & actuator colors black, nickel or pewter. 6 Pewter and nickel colors only available with laser etched actuator. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com V-Series Contura V Sealed Rocker Switches - Ordering Scheme | 13 V 1 D A B T 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp G P C 00 8 Bracket 9 Actuator Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 0 00 13 14 Legend Actuator Orientation Lens Legend No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 2 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No SealB One SealC 0 G P 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING Gray G H No Actuator Contura V Contura V, laser etched 10 Lens 0 - No Actuator Z - No Lens ClearWhite Amber Green Red 1 6 8 G M 2 7 C H N 3 8 D J P 4 9 E K R 5 A F L S .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE White W Y 9 ACTUATOR 3 RATING4 1 B C D E F M N 12 Legend Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Position: 11 Color 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) 1 SERIES V 10 Lens Blue T U V W Y bar bar/bar oval oval/bar oval/oval Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR COLOR1,3,3 No Actuator 0 Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) Black C Gray H Red S White Y Nickel D Pewter E 12 ACTUATOR LENS OR BODY LEGENDS2,6 11ON 12 OFF 13 I 14O OFF ONO I 15 O O 16 O O F N N F FF 17 O I 18 I O For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 4G13L 4G MC MA MA3MC MA 4G MC 3L 4G200 MA1MC ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 ORIENTATION 4 ORIENTATION 2 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Laser Etched rocker only available with lens code Z & actuator colors black, nickel or pewter. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Nickel and Pewter colors only available with laser etched actuator. 6 Consult factory for laser etched lens callout. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 14 | V-Series Contura IV & V Locking Sealed Rocker Switches - Ordering Scheme V 1 D A S W 0 B 4 5 6 Termination Illumination Lock 3 Rating 7 Lamp 1 SERIES V 2 ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 ONNONE OFF ONNONE ON ONOFF ON ONOFF (ON) (ON)OFF (ON) OFFNONE ON 11 Function 0 12 Legend 13 Legend Orientation No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No SealB One SealC White W Y Gray G H 9 HARD SURFACE ACTUATOR 3 RATING4 1 B C D E F M N 10 Lens Lamp above terminals 3 & 6 end of switch Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 SPDP 1A 4D 6J 7K 8L 9N 9 Actuator 7 LAMP CIRCUIT3 Position: J Z E 00 8 Bracket .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY MR 1 UP 3 (+) 6 (–) BlackGray Red White J KL M NPR S CONTURA V: Orientation BlackGray Red White UV WY Actuator orientation above terminals: 3,6 1,4 Actuator orientation above terminals: 3,6 1,4 10 LENS5 Z - No Lens ClearWhite Amber Green Red Blue A B C D E F bar lens G H J K L M oval lens Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR LOCK FUNCTION AND COLOR1 Lock Color Match Actuator Black White Red Safety Orange Gray Up Down Up & Down Center3 A HR1 BJ S2 CKT 3 DL V4 E M W5 F GN6 12 ACTUATOR LENS OR BODY LEGEND2 6 LOCK Lock above terminals 1 & 4 end of switch. W low profile lock CONTURA IV: Orientation Left Right Y6 high profile lock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Located at T3-6 end of switch. 6 Contura V style only. 00 - No Legend 21 22 OFF ON 25 O F F 26 O N 23 O 27 O 24 I 28 I For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 1 2 3 4 ORIENTATION 1 No legend Orientation 1 Orientation 2 Orientation 3 Orientation 4 JHAY3-100 JHAY3-200 JHAY3-300 ORIENTATION 2 2 Circuit ORIENTATION 4 1 Series P P P P P P NHAY3-100 NHAY3-200 NHAY3-300 Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com ORIENTATION 3 V-Series Contura VI WAVE Sealed Rocker Switches - Ordering Scheme | 15 V 1 D B G N T B 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 8 Bracket 7 Lamp H A 7 C B AC 9 Actuator 1 SERIES V 13 Insert Color 1 00 14 Actuator Lens 15 16 Legend Actuator Orientation Lens Legend No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No SealB One SealC 0 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING Gray G H H High Insert No Actuator L Low Insert 10,11 LENS4 0 - No Actuator Z - No Lens ClearWhite Amber Green – 7 C H 3 – D J 4 – E K – A F L .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE White W Y 9 ACTUATOR 3 RATING3 1 B C D E F M N 12 Color Lamp above terminals 3 & 6 end of switch Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 11 Lens 7 LAMP 2 CIRCUIT 10 Lens Red N P R S Blue U V W Y Bar Lens Translucent Bar Lens Transparent Oval Lens Transparent Oval Lens Translucent Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 12 ACTUATOR COLOR C Jumper No No Yes T2 to 5 No No No No S Gray Red 13 INSERT COLOR B C D Y White N Bright Nickel Plated S Satin Chrome Plated T Satin Nickel Plated W White Black Bright Chrome Plated Satin Chrome Painted 14 ACTUATOR LENS OR BODY LEGENDS2 00 - No Legend this location/No actuator 11ON 12 OFF 13 I 14O OFF ONO I 15 O O 16 O O F N N F FF 17 O I 18 I O For additional legend options & codes, visit us at www.carlingtech.com. Orientation 1 15 LEGEND ORIENTATION 0 1 2 3 4 VTHAACN-MC1MC No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 VTHA7CN-3M100 VTHWZCB-45146 VTLSZSC-70100 Orientation 2 Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) H Black Orientation 4 1 Series VTLLFHC-A813H VTLDECC-001MG Orientation 3 16 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators. Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 16 | V-Series Contura VII Sealed Rocker Switches - Ordering Scheme V 1 D A B T 0 B 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp Z R C 00 8 Bracket 9 Actuator SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No SealB One SealC 0 Z 1,4 10 LENS Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - No Actuator Z - No Lens White Amber Green Red Blue Lens style & location 6 B G MT 7 C H NU 8 D J PV 9 E K RW A F L SY 1 2 3 45 11 ACTUATOR COLOR/THUMB PRINT COLOR1 Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) 3,6 O N/A - No Actuator HGrey/Black YWhite/Black CBlack/Black SRed/Black ORIENTATION 4 5 ILLUMINATION & SWITCH SEALING No Actuator Contura VII ORIENTATION 2 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. ACTUATOR ORENTATION ABOVE TERMINALS STANDARD .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE Gray G H 9 ACTUATOR 3 RATING4 1 B C D E F M N White W Y 14 ACTUATOR LENS OR BODY LEGENDS2 11ON 12 OFF 13 I 14O OFF ONO I 15 O O 16 O O F N N F FF 17 O I 18 I O For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION 1 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 AA 46 46 3AA-146 ORIENTATION 3 2 ORIENTATION 2 1 ORIENTATION 1 ( ) - momentary ORIENTATION 4 Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V ORIENTATION 4 13 14 Legend Actuator Orientation Lens Legend Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Position: 0 00 12 Legend ORIENTATION 1 11 Color 6,7 LAMP (same coding for both selections) 1 SERIES V 10 Lens ORIENTATION 2 2 Circuit ORIENTATION 3 1 Series AA 3AA-246 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators. Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. 4 Legends available for lighted oval lens version only Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com V-Series Contura X, XI & XII Sealed Rocker Switches - Ordering Scheme | 17 V 1 D A B 6 0 1 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING4 1 B C D E F M N 10 Lens 11 Lens 0 00 12 Legend 13 14 Legend Actuator Orientation Lens Legend Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Position: 9 Actuator 6,7 LAMP (same coding for both selections) 1 SERIES V 6 P Z 00 8 Bracket .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING Jumper No No Yes T2 to 5 No No No No * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET) X & XI w/Flush Bracket # of gaskets0 1 2 Black B C D White WY Z Gray GH J 9 ACTUATOR No Actuator Contura X Contura XI Contura XII X, XI, XII w/Raised Bracket 0 1 1 4 2 5 3 6 0 Black Gray WhiteRed 1 23 4 6 78 9 J K N M 3,6 Actuator orientation above terminals: 1,4 10 LENS - ABOVE LAMP #1 TERMINALS1,4 11 LENS - ABOVE LAMP #2 TERMINALS3,6 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue Lens Style 38 D J P VBar 49 E K R WOne piece Square 5AF L S YTwo piece Square* (w/ clear top protective lens) 27CHNUTwo piece Square* (w/ smoke top protective lens) 16 B G M TTwo piece Square* (w/ white top protective lens) * All bottom lenses are molded of opaque material. Consult factory for other lens colors. Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 12 ACTUATOR LENS OR BODY LEGEND2 00 - No Legend this location/No actuator 11 ON 12 OFF 13 I 14 O OFF ON O I 15 O O 16 O O 17 O I 18 I O F N N F F F 21 22 23 24 OFF ON O I 25 O F F 26 O N 27 O 28 I For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION3 0 1 2 3 4 ORIENTATION OF ACTUATOR/LENS IN PANEL No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 6ZZ3G-100 6FFMA-4MC MA 3G ORIENTATION 1 ORIENTATION 2 Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red & gray actuators. Custom colors are available, consult factory. 3 With 2 square lenses, use sel. 12 for lens above lamp 1, & selection 14 for lens above lamp 2. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Not available with Contura XI rockers. No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V ORIENTATION 4 1 Series 70 G3 A7 MC 6ZZ3G-1A7 MA 6FFMA-3MC MC 6FZ70-100 14 ACTUATOR LENS LEGEND ORIENTATION 3 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 18 | V-Series Contura X Locking Sealed Rocker Switches - Ordering Scheme V 1 D A S W 0 1 1 Series 2 Circuit 4 5 6 Termination Illumination Lock 3 Rating 7 Lamp 1 SERIES V ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 4D ONNONE ON 6J ONOFF ON 9N OFFNONE ON SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING4 1 B C D E F M N 9 Actuator 10 Lens 11 Function 12 Legend 13 Legend Orientation Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 8 Bracket 0 6,7 LAMP (same coding for both selections) 2 CIRCUIT 1 P B 00 .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION/BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY MR 1 UP 3 (+) 6 (–) 6 LOCK Lock above terminals 1 & 4 end of switch. Wlock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Located over T1-4 end of switch. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Located over T3-6 end of switch. No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black No Gasket1 One Gasket4 White 2 5 Gray 3 6 9 HARD SURFACE ACTUATOR Black 1 Contura X Grey 2 Red 3 White 4 Actuator orientation above terminals: 3,6 1,4 10 LENS - ABOVE LAMP #2 TERMINALS5 Z - No Lens Clear White Amber Green Red Blue Lens Style 38 D J P VBar 49 E K R WOne piece Square 5AF L S YTwo piece Square* (w/ clear top protective lens) 27CHNUTwo piece Square* (w/ smoke top protective lens) 16 B G M TTwo piece Square* (w/ white top protective lens) * All bottom lenses are molded of opaque material. Consult factory for other lens colors. Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR LOCK FUNCTION AND COLOR3 Lock Color Match Actuator Black White Red Gray Safety Orange Up Down Up & Down A HR BJ S CKT DL V E MW F NY 12 ACTUATOR LENS OR BODY LEGEND2 00 - No Legend 21 22 OFF ON 25 O F F 26 O N 23 24 O 27 O I 28 I For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION3 0 1 2 3 4 Orientation 1 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 Orientation Orientation 2 4 1PM4F-1 45 4F MC 18K45-2 13DMC-1 Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Orientation 3 V-Series Contura XIV Sealed Rocker Switches - Ordering Scheme | 19 V 1 D B B C 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp FA P C AB 8 Bracket 9 Actuator 1 SERIES V 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8 - - 7 8 - - 7 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 2 3 Color No Gasket BlackB GrayG White W 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 34 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 1 Gasket 2 Gasket C D H J YZ 9 ACTUATOR STYLE 0 FA FB No Actuator - Furnished separately Contura XIV Contura XIV - Laser Etched 10 LENS COLOR / STYLE 0 - No Actuator Z - No Lens ClearWhite Amber Green 1 6 B G 2 7 C H 3 8 D J 4 9 E K 5 A F L 5 A N/A N/A .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) 5 ILLUMINATION 13 14 Legend Actuator, Orientation Lens Legends 8 BRACKET COLOR & PANEL SEAL 3 RATING3 4 TERMINATION / BASE STYLE 12 Legend * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. SPDP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE(OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 S* 2 & 3, 5 & 6 2 & 3 1&2 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 1 B C D E F 11 Actuator Color 6 & 7 LAMP No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V ( ) - momentary 1 10 Lens 1 00 Red M N P R S N/A Blue T U V W Y N/A PAD Printed Laser-Etched Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Lamps Illumination Type Lamp wired to Terminals S NONE – – A 1 INDEPENDENT 8 (+) 7 (–) B 1 DOWN 3 (+) 7 (–) C 2 UP 3 (+) 7 (–) D 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H 2 INDEPENDENT 8 (+) 7 (–) SINGLE POLE SWITCHES ONLY J 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) K 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L 1 DOWN 3 (+) 6 (–) M 1 UP 3 (+) 6 (–) N 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) U 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) 11 ACTUATOR COLOR1 O N/A - No Actuator CBlack SRed YWhite 12 ACTUATOR LENS or BODY LEGEND2 00 - No Legend this location/No actuator 11ON 12 OFF 13 I 14O OFF ONO I 15 O O 16 O O F N N F FF 17 O I 18 I O 13 LEGEND ORIENTATION 0 1 2 3 4 No legend Orientation 1 Orientation 2 Orientation 3 Orientation 4 1 2 3 4 14 ACTUATOR / LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. 3 Additional ratings available. See V-Series Switch Accessories page. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 20 | V-Series Contura Sealed Rocker Switch Actuators Separately Reduce inventory levels and cost by stocking actuators and base switches separately. Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes. Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes. Contura VI Actuator with lenses and inserts only: VV with code selections 9-16 Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes. Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes. Panel Seal: VPS Contura X & XI actuators without lenses separately: VVR 6 1 00 1 1 Actuator Separately 4 Actuator Legend 2 3 Actuator Lens Style/Color Opening 5 Legend Orientation 2 ACTUATOR STYLE & COLOR Black 1 6 Gray 2 7 3 LENS OPENING FOR1 1 2 3 4 15 O O 16 O O F N N F F F 17 O I J Black Z No lens square lens on top/ bar lens on bottom (Contura X only) 6 7 Legend Legend Orientation 5 Legend N White 1 Bar lens 00 - No Legend 21 OFF 22 25 O F F 26 O N M Red 2 Square lens 5, 7 LENS OR BODY LEGEND2 14 O I 23 ON O 27 O 24 I 28 I For additional legend options & codes, visit us at www.carlingtech.com. 18 I O ORIENTATION OF ACTUATOR/LENS IN PANEL 6 LEGEND ORIENTATION3 0 No legend 1 Orientation 1 2 Orientation 2 ORIENTATION OF ACTUATOR/LENS IN PANEL 5 LEGEND ORIENTATION1 No legend Orientation 1 Orientation 2 Orientation 3 Orientation 4 K Gray 3,4 LENS OPENING FOR For additional legend options & codes, visit us at www.carlingtech.com. 0 1 2 3 4 4 Lens Opening 3 Lens Opening 2 ACTUATOR STYLE & COLOR Red 4 9 4 ACTUATOR LENS OR BODY LEGEND 00 - No Legend this location 11 ON 12 OFF 13 I OFF ON O 2 Style & Color 1 CONTURA XII ACTUATOR SEPARATELY VVP White 3 8 5 One bar lens One bar lenses One square lens two square lens VVP J 1 Z 21 1 00 1 Actuator 1 CONTURA X & XI ACTUATOR SEPARATELY VVP Contura X Contura XI Contura XII actuators without lenses separately: ORIENTATION 2 Contura X, XI & XII actuator lens assembly separately: ORIENTATION 1 ORIENTATION 4 ORIENTATION 1 VVL 2 1 00 0 ORIENTATION 2 1 Lens Separately ORIENTATION 3 2 Lens Style 4 Legend 3 Lens Color 5 Legend Orientation 1 CONTURA X, XI & XII LENS SEPARATELY VVL Contura X, XI & XII top piece of 2-piece lens separately: VVT 1 1 Lens Separately 1 TOP OF LENS SEPARATELY VVT 1 Clear 2 Smoke 3 White Contura X, XI & XII actuator lens assembly: top lens actuator stem posts mount toward actuator stem bottom lens } two piece lens assembly 1 piece lens/bar lens are positioned the same as bottom lens for assembly, minus the top lens. Lenses snap in from bottom. Notes: 1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2 must be chosen. 2 Center of actuator marking not available for Contura XII. 3 Legend is not available for bar style lens. 4 Not recommended with neon lamps. 5 Must also order top piece of 2 piece square lens separately. 2 One Piece Square lens 3 Bottom of Two-Piece Square lens5 3 TRANSLUCENT LENS COLOR 1 Clear 2 COLOR 2 Color 2 LENS STYLE3 1 Bar lens 2 White 3 Amber 4 Green4 4 LENS OR BODY LEGEND2 00 - No Legend 21 OFF 22 25 O F F 26 O N ON 23 5 Red O 27 O 24 6 Blue4 I 28 I For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 5 LEGEND ORIENTATION3 0 1 2 3 4 No legend Orientation 1 Orientation 2 Orientation 3 Orientation 4 ORIENTATION 1 ORIENTATION 4 ORIENTATION 2 ORIENTATION 3 Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com V-Series Contura Sealed Rocker Switch Accessories | 21 Easily integrate Contura products into your system, with Contura Accessories Q.C. SELECTION GUIDE Contura ConnectorsPART NO COMPANY SERIES WIRE RANGE Q.C. SELECTION TIN GUIDE PLAIN COMPANY SERIES ORIENTATION MM 2 AWG WIRE RANGE PLATED BRASS BRASS PART NO (REF) 12 3.0 ORIENTIN 2 TATION PLAIN 02965471 AWG(2)16-14 PLATED Q.C. SELECTION Q.C.12010601 SELECTION GUIDE Q.C. SELECTION GUIDE MM(2)1.0-2.0 GUIDE BRASS 02965470BRASS 16-14 (REF) 1.0-2.0 02965580 PACKARD 58 SERIES B WIRE WIRE WIRE PART NO PART NO RANGE PART 20-18 NO RANGE 02965580 12 3.0 02965469 06288318 .5-.8 RANGE COMPANY COMPANY ORIENORIENORIEN12010601 02965471 COMPANY (2)16-14 102TIN (2)1.0-2.0 TIN TIN 5.0 2 12084590 PLAIN PLAIN PLAIN SERIES SERIES SERIES TATION TATION TATION AWG MM AWG MM AWG MM 2 PACKARD PLATED PLATED Q.C. SELECTION GUIDE BRASS BRASS BRASS TANG 02965470 PLATED 16-14 1.0-2.0(REF) B (REF) 12 3.0 (REF) BRASS 12052224 BRASS BRASS 58 SERIES WIRE 02965469 02965580 06288318 20-18 3.0 .5-.8 3.0 02965580 1202965580 12 12 3.0 PART NO12015870 16-14 1.0-2.0 RANGE PACKARD 12010601 12010601 120106015.0(2)1.0-2.0 02965471 (2)16-14 (2)16-14 (2)16-14 (2)1.0-2.0 02965471 02965471 COMPANY ORIEN10(2)1.0-2.0 12084590 Q.C. 12020035 SELECTION GUIDE (2)22-18 (2).5-.8 A METRI-PACK TIN PACKARD PACKARD PACKARD 2 SERIES TATION TANG B1.0-2.0 B 02965470 PLAIN 02965470 16-14 02965470 16-14 MM 16-14 AWG PLATED 12 1.0-2.0 3.0 B1.0-2.0 SERIES58 58630 SERIES SERIES BRASS 58 12052224 SERIES WIRE 12015869 20-18 .5-.8 12015832 (REF) BRASS PART NO20-18 02965469 06288318 02965469 06288318 02965469 .5-.8 20-18 06288318 .5-.8 20-18 .5-.8 RANGE 12015870 16-14 1.0-2.0 12 5.0 PACKARD COMPANY 02965580 20-22 .35-.5 10 10 3.0 5.0 10ORIEN5.0 12084590 12052222 12084590 12084590 TIN TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT PLAIN SERIES 02965471 METRI-PACK 12020035 (2)22-18 (2).5-.82 12TATIONA 3.0 12010601 (2)16-14 TANG TANG TANG AWG 12052224 12052224 12052224 12 3.0 12(2)1.0-2.0MM 3.0 PLATED 16-12 1.3-3 BRASS 630 SERIES PACKARD (REF) SYMBOL B 02965470 16-14 1.0-2.0 BRASS 60253-2 60253-1 12015832 12015869 20-18 .5-.8 58 SERIES 12015870 12015870 12015870 16-14 1.0-2.0 16-14 1.0-2.0 16-14 1.0-2.0 AMP PACKARD PACKARD 02965469 PACKARD (2) 16 (2) 1.3 20-18 12 .5-.8 3.0 02965580 06288318 250 SERIES (2)22-18 (2)22-18 A(2).5-.8B A 12020035 12020035 12020035 METRI-PACK METRI-PACK METRI-PACK 12052222(2)22-18 20-22(2).5-.8 .35-.5A(2).5-.8 TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT 12010601 (2)1.0-2.0 .8-2 02965471 10 (2)16-14 5.0 12084590 630 SERIES 630 SERIES 630 SERIES 42100-2 18-14 FASTIN-FASTON 42100-1 12015869 12015869 12015869 20-18 .5-.8 20-18 .5-.8 20-18 .5-.8 TANG 12015832 12015832 12015832 PACKARD 16-12 1.3-3 12 16-14 3.0 B 02965470 12052224 1.0-2.0 SYMBOL 58 SERIES 60253-1 60253-2 20-22 .35-.5 20-22 .35-.5 20-22 .35-.5 12052222 12052222 12052222 60295-2 22-18 .3-.9 60295-1 AMP TANG SYMBOL = TANG SYMBOL = TANG SYMBOL = SHOWS ORIENTATION SHOWS OFORIENTATION TANG IN SHOWS SLOT OFORIENTATION TANG IN SLOT OF TANG IN SLOT 12015870 16-14 1.0-2.0 02965469 06288318 (2) 16 20-18 (2) .5-.8 1.3 PACKARD 250 SERIESMETRI-PACK 16-12 (2)22-18 1.3-3 16-12(2).5-.8 1.3-3 16-12 B 1.3-3 A 12020035 SYMBOL SYMBOL SYMBOL 10 5.0 and availability. 12084590 60253-2 60253-2 60253-2 60253-1 60253-1 60253-1 AMPConsult AMP AMP FASTIN-FASTON 42100-1 18-14 .8-2 42100-2 NOTE: Delphi Packard and/or Amp on actual part numbers 630 SERIES (2) 16 (2) 1.3 (2) 16 (2) 1.3 (2) 16 (2) 1.3 TANG 12015869 20-18 12 3.0 B 250 SERIES SERIES 12015832 250 SERIES B B AMP is 250 a registered trademark of12052224 AMP Inc. Harrisburg,.5-.8 PA 60295-1 FASTIN-FASTON 60295-2 22-18 .3-.9 18-14 .8-218-14 .8-2 42100-2 42100-2 42100-2 FASTIN-FASTON FASTIN-FASTON 42100-1 42100-1 42100-1 20-2216-14 .35-.5 12052222 12015870 1.0-2.0.8-218-14 Delphi Packard Warren, Ohio SHOWS ORIENTATION OF TANG IN SLOT TANG SYMBOL = PACKARDis a registered trademark of Delphi-Packard Electrical Systems 22-18 .3-.9 22-18 22-18 A .3-.9 60295-2 60295-2 60295-2 60295-1 60295-1 12020035 60295-1 16-12 1.3-3(2).5-.8.3-.9 (2)22-18 METRI-PACK SYMBOL 60253-1 Amp60253-2 NOTE: Consult Delphi on actual part numbers and availability. AMP 630Packard SERIES and/or 12015869 (2) 1620-18 (2) 1.3 .5-.8 12015832 .820[20.83] 250 SERIES NOTE: Consult NOTE: Packard Consult and/or Delphi NOTE: Amp Packard Consult onAMP actual and/or Delphi partAmp numbers Packard on actual and/or and part availability. numbers on actual and part availability. numbers and availability. AMP is aDelphi registered trademark of Inc. Harrisburg, PAAmp B 18-14 .8-2 FASTIN-FASTON 42100-1 20-22of AMP .35-.5 12052222 AMP isPackard a registered AMP trademark is a registered of AMP AMP trademark Inc. is42100-2 Harrisburg, a registered of AMP PA trademark Inc. Harrisburg, PAInc. Harrisburg, PA Warren, TANG Delphi is.820[20.83] a registered trademark of Delphi-Packard Electrical Systems Ohio SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT Delphi Packard is Delphi a registered Packard trademark is Delphi a registered of Packard Delphi-Packard trademark is a registered of Electrical Delphi-Packard trademark Systems of Electrical Warren, Delphi-Packard Systems Ohio Electrical Warren, Ohio Systems Warren, Ohio 22-18 .3-.91.3-3 60295-2 60295-1 16-12 SYMBOL 60253-2 60253-1 AMP (2) 16 and availability. (2) 1.3 NOTE: Consult Delphi Packard and/or Amp on actual part numbers 250 SERIES .820[20.83] .820[20.83] B .820[20.83] .820[20.83] .820[20.83] .820[20.83] .820[20.83] AMP is a registered trademark Inc. Harrisburg, PA 18-14 .8-2 42100-2 FASTIN-FASTON 42100-1 of AMP Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio 22-18 .3-.9 60295-2 60295-1 .820[20.83] .770[19.56] .820[20.83] NOTE: Consult.820[20.83] Delphi Packard and/or Amp on actual part numbers and availability. AMP is a registered trademark of AMP Inc. Harrisburg, PA Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio .920[23.37] A .920[23.37] A .920[23.37] A PACKARD 630 PACKARD 630 A B .820[20.83] VC1 B VC1 PACKARD 630 A .920[23.37] B A AMP, 58 AMP, PACKARD 58 AMP, PACKARD 58 PACKARD 630 PACKARD PACKARD 630 VC1 VC1 B B .920[23.37] .920[23.37] A A PACKARD 630 PACKARDPACKARD 630 630 VC1 VC1 VC1 PACKARD 630 VC1 VC1 B B A A AMP, 58 AMP, PACKARD AMP, PACKARD 58 630 58 PACKARD AMP, PACKARD 58 PACKARD B .920[23.37] A PACKARD 630 VC2 B A VC1 B .820[20.83] .920[23.37] .920[23.37] VC2 AMPAMP, PACKARD 58 PACKARD 630 AMP, PACKARD 58 VC2 A VC2 AMP,1.266[32.16] PACKARD 58 1.266[32.16] 1.466[37.24] 10 3A 1.266[32.16] 2 1 8 7 41.466[37.24] 5 1.466[37.24] 69 A 1.266[32.16] AMP, PACKARD 58 10 3 2 1 8 7 4 5 69 AMP 5 AMP 679 A VC2 B AMP PACKARD 630 58 VC2 AMP, PACKARD 4 73 45 2 A VC2 PACKARD 630 69 15 8 6 9 A 1.170[29.72] .770[19.56] PACKARD 630 .950[24.13] A B .770[19.56] B PACKARD 630 2 VC21 8 7 4 5 69 B 58AMP, PACKARD .950[24.13] 1 87 4 5 3 4 235 1 62 8 B AMP AMP AMP, PACKARD 58 AMP, PACKARD 58 1.250[31.75] 1.250[31.75] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.466[37.24] 10 3 2 11.266[32.16] 81.266[32.16] 7 4 5 6 9 1.466[37.24] 1.466[37.24] AMP, PACKARD A4 3 A2 1 8 7 58 5 6 10 3 A A .950[24.13] .950[24.13] PACKARD 630 A AMP, 58 PACKARD AMP, AMP, PACKARD PACKARD 58 B A .950[24.13] PACKARDBA630 B AMP, PACKARD 58 1.170[29.72] 1.170[29.72] 1.170[29.72] PACKARD 630 A PACKARD PACKARD 630 630 .950[24.13] 3 2 1.170[29.72] 1 8 7 B AMP .770[19.56] 1.170[29.72] A AMPAMP AMP 1.170[29.72] VC2 VC2 10 10 3 23 1 28 10 84 1053 6729 417VC1 845VC1 56 96 9 10 73 4 2 51 689 10 10 3 32.920[23.37] 128 1 7104 8 3 5 2 619 8VC27 4 1 38 2 1 7.920[23.37] B B AMP, PACKARD 58 .770[19.56] .770[19.56] .920[23.37] .920[23.37] .920[23.37] VC2 AMP AMP VC2 .770[19.56] 58 7 1.250[31.75]B AMP, PACKARD 58 MARKING 10 3DETAIL 2 1 FRONT VIEW FRONT VIEW VC1 VC1 AMP, PACKARD 58 8 AMP MARKING 7 4DETAIL 5 69 REAR VIEW REAR VIEW VC1 MARKING 10 3 DETAIL 2 1FRONT 8 VC2 FRONT VIEW VC2 VIEW AMP MARKING 7 4 DETAIL 5 69 REAR VIEW VC2 PACKARD 630 AMP, PACKARD 58 MARKING DETAIL REAR VIEW 3 2 1 8 FRONT VCHVIEW AMP, PACKARD 58 MARKING DETAIL VIEW FRONT 4 5 6 REAR7 VIEW VCH VCH MARKING DETAIL MARKING HOUSING DETAIL MARKING DETAIL MARKINGCONNECTOR DETAIL MARKING DETAIL HOUSING CONNECTOR HOUSING CONNECTOR HOUSING 1.250[31.75] 1.266[32.16] 1.466[37.24]CONNECTOR HOUSING 1.266[32.16] 1.466[37.24] CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR VCH VC2 FRONT VIEW REAR VIEW FRONT FRONT VIEW (For AMP terminals only) (For AMP terminals only) REAR VIEW (For AMP VIEW terminals only) VC1 VC1 VC2 VCH CONNECTOR HOUSING CONNECTOR HOUSING MARKING DETAIL CONNECTOR (For AMP terminals only) FRONT VIEW MARKING DETAIL REAR VIEW DETAIL HOUSINGMARKING REAR VIEW (ForVC2 AMP terminals only) CONNECTOR VC2 HOUSING CONNECTOR HOUSING (For AMP terminals only) Contura X Boot (P/N VB1-01) CONNECTOR HOUSING FRONT VIEW 6 AMP, PACKARD 58 7 4 5 6 7 4 5 6 MARKING DETAIL REAR VIEW MARKING DETAIL REAR VIEW MARKING DETAIL REAR VIEW MARKING DETAIL CONNECTOR REAR VIEW HOUSING VCH CONNECTOR HOUSING Additional V-Series Ratings VCH CONNECTOR HOUSING 1 .4VA @ 28VDC Resistive 4 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings 1.050[26.67] 1.050[26.67] 1.050[26.67] 1.050[26.67] 51 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified 62 15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85 VB1-01 VB1-01 2 VB1-01 7VB1-01 15A 125VAC 1/2 XHP, 12(6)A 125 VAC T85 2.000[50.80] 2.000[50.80] 2.000[50.80] CONTURA X BOOT CONTURA X BOOT CONTURA BOOT 1.050[26.67] 1.050[26.67] 2.000[50.80] CONTURA X BOOT 2 8 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85 1.050[26.67] 92 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85 VB1-01 B CONTURA X BOOT 15A 24V VB1-01 2.000[50.80] .757[19.23] .757[19.23] .757[19.23] .757[19.23] CONTURA X BOOT 2.000[50.80] C 20A 18V VB1-01 2.000[50.80] CONTURA X BOOT D 20A 12V E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only) .757[19.23] F 10A 14V, 6A, 14VT (circuit G only) G 20A 6V V Actuator Removal Tool .757[19.23] H 20A 3V 3.99 [101.35] .757[19.23] 3.99 [101.35] 3.99 [101.35] 3.99 [101.35] L 15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L VRT MVRT REMOVAL .4VA/20A 12V VRT (combi-contact) VRT ACTUATOR TOOL .900 [22.86] ACTUATOR REMOVAL ACTUATOR REMOVAL ACTUATOR REMOVAL contacts for borderline dry circuit applications) 3.99 [101.35] TOOL (combination gold/silver (For flush bracket) .900 [22.86] .900 [22.86] .900 [22.86] TOOL TOOL (For flush (For .4VA/15A flush bracket) (For flush bracket) N bracket) 24V (combi-contact) VRT REMOVAL ACTUATOR TOOL (combination gold/silver contacts for borderline dry circuit applications) .900 [22.86] TOP INSERT POINTS UNDER ACTUATOR TOP Contura II, III, IV & (P/N VRT) (For AMP terminals only) CONNECTOR HOUSING MARKING DETAIL 5 TOP MARKING DETAIL CONNECTOR HOUSING FRONT VIEW VC1 CONNECTOR HOUSING VC1 4 AMP, PACKARD 58 1.250[31.75] 3 2 1 8 PACKARD 630 PACKARD 630 VC1 VC1 VC2 1.250[31.75] 1.266[32.16] 1.466[37.24] 1.466[37.24] MARKING DETAIL1.266[32.16] MARKING MARKING DETAIL DETAIL MARKING DETAIL MARKING MARKING DETAIL DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING MARKING DETAIL DETAIL MARKING DETAIL MARKING MARKING DETAIL DETAIL MARKING DETAIL .950[24.13] BMARKING DETAIL B FRONT VIEW DETAIL FRONT VIEW REAR1.466[37.24] FRONT VIEW VIEW REAR VIEW FRONT REARVIEW VIEW FRONT VIEW DETAIL FRONT REAR VIEW VIEW REAR VIEWMARKING FRONT REAR VIEW VIEW FRONT VIEW REAR FRONT VIEW VIEW REAR VIEW B DETAIL B 1.266[32.16] 1.266[32.16] 1.466[37.24] 1.250[31.75] MARKING MARKING DETAIL MARKING MARKING DETAIL PACKARD 630 B PACKARD 630 B AMP, PACKARD 58 6 PACKARD 630 PACKARD 630 TOP INSERT POINTS UNDER INSERTAND POINTS INSERT POINTS UNDER HOLD FLUSH ON BRACKET PUSHUNDER ACTUATOR IN ACTUATOR ACTUATOR HOLD FLUSH ON BRACKET ANDHOLD PUSH FLUSH ON BRACKET AND HOLD PUSH FLUSH ON BRACKET AND PUSH IN INTOP IN TOP TOP TOP INSERT POINTS UNDER ACTUATOR HOLD FLUSH ON BRACKET AND PUSH IN TOP TOP (For flush bracket) 3.99 [101.35] 3.99 [101.35] NOTES Consult factory to determine availability for individual circuits and their HP rating. VRT VRT 1. Not avaiable with Contura 7 or 14 rocker styles. ACTUATOR REMOVAL INSERT POINTS UNDER ACTUATOR INSERT POINTS UNDER 2. Ratings 6 - 9 REMOVAL are UL, CSA & VDE certified, require terminations A or B for double .900 [22.86] ACTUATOR TOOL ACTUATOR TOOL HOLD FLUSH ON BRACKET AND PUSH.900 [22.86] HOLD FLUSH INON BRACKET AND PUSH (For flush bracket) pole(For circuits, are not available with illumination circuits 4, 8, D, J, N, & T or with IN flush & bracket) TOP TOP wire lead or solder lug terminations. Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8. Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only. TOP TOP Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 22 | V-Series Contura Sealed Rocker Switch Accessories Contura Mounting Panels Dimensional Specifications: in. [mm] Contura Hole Plug Dimensional Specifications: in. [mm] 1.450 [36.83] .830 [21.08] TEST CUT HOLE IN ACTUAL MATERIAL VHP CONTURA II,III HOLE PLUG 1.240 [31.50] 1.820 [46.23] .430 [10.92] VHP CONTURA II,III HOLE PLUG VH1 STANDARD HOLE PLUG (No wing serrations) (With VC1 connector attached) 2.000 [50.80] VH2 STANDARD HOLE PLUG (With wing serrations) 1.067 [27.10] (TYP. FOR VH3 & VH4) 1.928 [48.97] VH3 CONTURA IV HOLE PLUG (No wing serrations) VH4 CONTURA IV HOLE PLUG (With wing serrations) DETAIL VIEW VH1,VH3 & VH5 HOLE PLUGS (No wing serrations for ease of removal) 1.020 [25.91] (TYP. FOR VH5 & VH6) VH5 CONTURA V HOLE PLUG (No wing serrations) VH6 CONTURA V HOLE PLUG (With wing serrations) DETAIL VIEW VH2,VH4 & VH6 HOLE PLUGS (With wing serrations) Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Notes | 23 * Intentionally left blank Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: [email protected] • www.carlingtech.com East Region Sales Office, CT • [email protected] Midwest Region Sales Office, IL • [email protected] West Region Sales Office, CA • [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277 • Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China • [email protected] Shanghai, China • [email protected] Pune, India • [email protected] Kaohsiung, Taiwan • [email protected] Yokohama, Japan • [email protected] Europe/Middle East/Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Int + 44 1392-364422 • Fax: Int + 44 1392-364477 Email: [email protected] GmbH, Germany • [email protected] SAS, France • [email protected] REV_SW_V_06_2014
Similar documents
V-Series - Carling Technologies
V-Series Contura Switches V-Series switches offer countless unique options including choices for ratings, colors, illuminations and symbols. These switches feature removable actuators in a choice o...
More information