V-Series - Carling Technologies

Transcription

V-Series - Carling Technologies
V-Series
Contura Switches
Product Highlights:
Maximum sealing protection with dual seals around lamps
and rocker stem, certified to IP66 & IP68. Optional panel
seals for additional protection.
ŠŠ Silver plated butt contact mechanism provides 50 to
100 thousand electrical cycles and a variety of different
electrical ratings.
ŠŠ Roller pin mechanism does not require lubricants and
allows the switch to withstand extreme temperatures.
ŠŠ The switch base accommodates up to 10 terminals and a
large variety of switch and lighting circuits.
ŠŠ The multi-step mounting wings provide a secure fit for
panel thicknesses of 0.032” thru 0.250” in an industry
standard 0.830” x 1.450” mounting hole.
ŠŠ The switch connector allows the user to preload FQC
terminals for easy assembly to switch base.
ŠŠ Numerous choices of removable rockers allow for style
change without having to retest or re-qualify the switch
base.
ŠŠ Illumination options are endless with bar, oval, and square
lenses available with choices of incandescent, neon and
a wide variety of LEDs including superbrite, megabrite,
flashing and bicolor lighting.
ŠŠ Available with a variety of complimentary mounting
panels, hole plugs, illuminated indicators and boots to
accommodate most any design need.
ŠŠ
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: [email protected]
Application Support: [email protected]
Phone: (860) 793-9281 • Fax: (860) 793-9231
www.carlingtech.com
CONTURA III
CONTURA V
CONTURA II
CONTURA VII
Carling Technologies’ fully sealed V-Series Contura switches
are well known for their cutting edge design, high quality,
maximum performance and unmatched reliability. These
switches are a staple in the marine and transportation
industries and have passed a range of environmental,
corrosion, temperature, vibration, shock and sealing tests
including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC
60529 and BS 5490 among others, making them one of the
most rugged and reliable switches ever manufactured.
2 | V-Series Contura Sealed Rocker Switches
V-Series Switch
DESIGN FEATURES
INTERCHANGEABLE ACTUATORS
Panel redesign is a snap with our wide
range of rocker styles. Achieve maximum
design variety with minimum inventory.
Simply swap rockers to create an entirely
new look for your panel.
OPTIONAL PANEL SEAL
Prevents water/dust
ingress behind panel.
DUAL SEAL PROTECTION
Seals out water, dust,
debris, and enables switch
certification to IP66/IP68 for
front panel components.
MULTIPLE LIGHTING OPTIONS
In addition to Incandescent
lamps, our LED illumination is
offered in a wide array of light
intensities, colors, as well as
dual level, tri-color, and flashing
options.
CLEAN CONNECTIONS
Options for both eight and ten
terminal base styles with AMP &
Packard compatible connectors
affords myriad circuit options
while providing ease of assembly.
BRASS ROLLER PIN
Robust mechanism
eliminates the need for
lubricants. Enables switch
to withstand -40°C to
+85°C temperatures.
SILVER PLATED BUTT
CONTACT MECHANISM
Providing 50k to 100k
electrical cycles and
a variety of different
electrical ratings.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura Sealed Rocker Switches & Illuminated Plug | 3
Contura II & III
Contura X
The Contura II & III actuators are
constructed of thermoplastic
polycarbonate and are offered
with a hard nylon overlay or a
“soft-touch” elastomer overlay.
These models incorporate
aesthetic designs on the top and
bottom of the rocker featuring
two rows of raised “bumps” on the
Contura II and three “indented”
lines on the Contura III.
The raised bracket/bezel on
the Contura X helps prevent
inadvertent actuation of the
rocker, as well as preventing
debris from being trapped under
the actuator. This curved rocker
style is available with a variety of
lenses and legends.
Contura IV
Contura XI
The Contura IV’s “Shape to create
a Shape” actuator works with the
curves, contours & advanced
styling of the latest panel designs,
flowing with these advanced
curves & radii. This actuator style
fits on the Contura flush bracket/
bezel.
Contura V
The raised bracket/bezel on
the Contura XI helps prevent
inadvertent actuation of the
rocker, as well as preventing debris
from being trapped under the
actuator. This convex style rocker
is available with a wide variety of
lenses and legends.
Contura XII
The symmetrically curved
Contura V actuator provides
the perfect complement to the
Contura IV’s “Shape to create a
Shape” design concept. With its
flush style mounting bracket,
Contura V can be mounted in
between two Contura IV’s, by
itself, or in groups.
The Contura XII version features
a paddle style actuator with
the raised bracket/bezel of
Contura X and XI. The contoured
handle design provides intuitive
recognition and ease of operation
and is available with all Contura X
and XI lens and legend offerings.
Contura VI (WAVE)
Contura XIV
The Contura VI WAVE sealed
rocker switches, when used in a
row, create an uniquely appealing
“wave” design on your panel. A
variety of colors and finishes are
available for both rocker and wave
insert. Contura VI features bar and
oval lenses.
Contura VII
Contura VII featuring gently
curved corners and edges
assuring compatibility with most
any panel design. Intuitive feel
is maximized by the use of 2
embossed circular pads located at
opposite ends of the rocker. Any
combination of Bar or Oval style
lenses can be located in the pads
providing a truly unique look,
exclusive to Contura VII.
The Contura XIV represents a sleek
new crossover rocker design which
should appeal to Trucks, Buses and
Heavy Vehicles as well as the Marine
Industry. Intuitive feel is provided by
recessed ridges along with a Center
Groove which effectively defines the
boundary between top and bottom
switch functions.
V-Series Illuminated
Indicators & Accessories
Alert operator of systems functions
or malfunctions, are offered with
removable/replaceable lamps in
Contura II, II, V or X styles. Accessories
include connectors, mounting
panels, hole plugs, panel seals, and
actuator removal tools. Refer to
accessories page for full details
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
4 | V–Series Contura Sealed Rocker Switches - General Specifications
Electrical
Contact Rating .4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
10A, 14VT
6A, 125VAC L
Dielectric Strength 1500 Volts RMS
Insulation Resistance 50 Megohms
Initial Contact Resistance 10 milliohms max. @ 4VDC
Life 50,000- 100,000 cycles circuit
dependent
Contacts Silver alloy, silver tin-oxide, fine silver
Terminals Brass or copper/silver plate 1/4”
(6.3mm) Quick Connect terminations standard. Solder lug, Wire Lead
Mechanical
Endurance Physical
150,000 cycles minimum
circuit dependent
Lighted Incandescent - rated 10,000 hours Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24VDC)
Seals Internal
Optional external gasket panel seal
Base Polyester blend rated to 125°C with
a UL flammability rating of 94V0.
Contura II,III,IV,V,
Hard Surface: Basic actuator VI, VII Actuator
structure molded of thermoplastic
polycarbonate with a hard Nylon 66 thermoplastic surface overlay.
Soft Surface: Basic actuator structure
molded of thermoplastic polycarbonate
with an elastomer overlay.
Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C
Lens Polycarbonate rated at 100°C
Contura XIV
Polycarbonate lens/subrocker with ABS shell
Actuator Travel (Angular Displacement)
2 position 3 positions 18°
9° from center
Mounting Specifications
.830[21.08]
Panel Thickness Range
Gaskets Acceptable Panel Thickness
0
.030 to .250 (.76mm to 6.35mm)
TEST CUT
1.450[36.83] HOLE IN
1
.030 to .109 & .147 to .157
ACTUAL
MATERIAL
(.76 to 2.77mm & 3.73 to 3.98mm)
Recommended: No gasket with panel
SWITCH
thickness of .032, .062, .093, .125,.187 or .250
MOUNTING HOLE
Agency Certifications
Environmental
Sealing Sealed version: IP68, in accordance
with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual
switch only, and signifies protection
against dust and the prolonged effects of immersion under pressure.
The standard test for immersion
under pressure requires submersion
under one meter of water for 30 min.
The V-Series switch has exceeded
these parameters, having
been actuated and illuminated during
submersion.
Corrosion Mixed Flowing Gas (MFG) Class III
3 year accelerated exposure per ASTM B-827, B-845 Silver and gold contacts
Operating Temp. -40°C to + 85°C
Vibration 1 Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or 10G’s
10-500 Hz. Tested with VCH connector.
Test criteria - No loss of circuit during
test, pre and post test contact resistance.
Vibration 2 Resonance search
24-50 Hz 0.40 DA
50-2000 Hz ±10 G’s peak
Horizontal Axis 3-5 G’s max.
Random
24 Hz 0.06 PSD-Gsq/Hz
60 Hz 0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10μ
seconds chatter.
Shock Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with
VCH connector. Test criteria - No loss
of circuit during test, pre and post
test contact resistance.
Salt Spray Per Mil-Std 202F, Method 101D, Test
Condition A, 96 Hrs. Sealed version only.
Dust Per Mil-Std 810C, Method 510.2 Air
Velocity 300 ±200 Feet/Min, Test
Duration 16 Hrs.
Thermal Shock Per Mil-Std 202F, Method 107F, Test
Cond. A, -55°C to 85°C. Test criteria pre and post test contact resistance
Moisture Resistance Per Mil-Std 202F, Method 106F, Test
Criteria - pre and post test contact
resistance
Ignition Protection All Contura switches with sealed
construction meet the requirements
of UL1500/ISO8846 for ignition
protection, in addition to
conformance with EC directive
94/25/EC for marine products.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V–Series Contura II, III, & IV | 5
Dimensional Specifications: in. [mm]
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
6 | V-Series Contura V, VI & VII
Dimensional Specifications: in. [mm]
CONTURA V
CONTURA V
SHOWN WITH
BAR LENS
SHOWN WITH
LOW PROFILE LOCK
1.922[48.56]
1.922[48.56]
1.079
[27.40]
1.550
[39.37]
.505
[12.83]
.250
[6.35]
X
.031
[.78]
.250
[6.35]
X
.031
[.78]
.820
[20.83]
.960
[24.38]
8 TERMINAL BASE
W/O BARRIERS
7
8
1
2
5
2
5
3
6
3
6
1
SWITCH SHOWN WITH
VCH CONNECTOR 8
TERMINAL
BOTTOM VIEW
TERMINAL
ARRANGEMENT
8 TERMINAL BASE
10
.250 [6.35]
.031 [.78]
.820
[20.83]
10 TERMINAL BASE
W/O BARRIERS
4
8
2.029
[51.53]
0.985
[25.02]
.960
[24.38]
.960
[24.38]
8 TERMINAL BASE
W/BARRIERS
10 TERMINAL BASE
W/O BARRIERS
1.000
[25.40]
.250
[6.35]
X
.031
[.78]
.390
[9.90]
1.922[48.82]
10 TERMINAL BASE
W/BARRIER AND
LAMP TERMINAL
1.020
[25.91]
.505
[12.83]
SHOWN WITH LARGE LENS
AND BAR LENS
1.126
8 TERMINAL BASE
W/O BARRIERS
1.020
[25.91]
CONTURA VII
SHOWN WITH OVAL
LENS
1.950[49.53]
.080[2.03]
1.479
[37.57]
8 TERMINAL BASE
W/BARRIERS
CONTURA VI
.820
[20.83]
.960
[24.38]
10 TERMINAL BASE
W/O BARRIERS
7
4
9
BOTTOM VIEW
TERMINAL
ARRANGEMENT
10 TERMINAL BASE
SWITCH SHOWN WITH
VC1 CONNECTOR 10
TERMINAL
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
SWITCH SHOWN
WITH VC1
CONNECTOR 10
TERMINAL
V-Series Contura X, XI, XII & XIV | 7
Dimensional Specifications: in. [mm]
CONTURA X STYLE
CONTURA XI STYLE
SHOWN WITH RAISED BRACKET
.350
[8.89]
SHOWN WITH PADDLE
ACTUATOR
CONTURA XIV STYLE
SHOWN WITH LARGE LENS
1.928
[48.97]
.667 [16.94]
1.910[48.51]
CONTURA XII STYLE
SHOWN WITH RAISED
BRACKET AND TWO SQUARE
LENSES
1.910[48.51]
.426[10.82]
.350[8.89]
1.586[40.28]
.573
[14.56]
1.305[33.15]
1.506[38.25]
1.370[34.79]
1.370[34.79]
1.370[34.79]
8 TERMINAL BASE
W/BARRIERS
10 TERMINAL BASE
W/O BARRIERS
.960[24.38]
8 TERMINAL BASE
W/O BARRIERS
.960[24.38]
.960[24.38]
.780[19.81]
10 TERMINAL BASE
W/O BARRIERS
.970
[24.64]
.780[19.81]
.780[19.81]
.250[6.35]
X
.031[.78]
.390[9.90]
.390[9.90]
.820[20.82]
8 TERMINAL BASE
W/BARRIERS
SWITCH SHOWN WITH
VCH CONNECTOR
8 TERMINAL
.390[9.90]
.820[20.82]
.820[20.82]
10 TERMINAL BASE
W/BARRIERS
10 TERMINAL
BASE
W/O BARRIERS
8
1
7
4
8
7
1
4
2
5
2
5
3
6
3
6
BOTTOM VIEW
TERMINAL
ARRANGEMENT
8 TERMINAL BASE
10
.820
[20.83]
9
BOTTOM VIEW
TERMINAL
ARRANGEMENT
10 TERMINAL BASE
SWITCHES SHOWN WITH
VC1 CONNECTOR
10 TERMINAL
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
.960
[24.38]
8 | V-Series Contura II to XIV - Circuit Diagram
CIRCUIT
CIRCUIT DIAGRAM
CIRCUIT
CIRCUIT DIAGRAM
3
1
3
2
3
5
3
3
3
1
2
5
3
4
6
2
2
1
3
4
2
6
4
5
6
5
SYMBOL LEGEND
2
5
3
4
DEFINITION
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION
H
2
5
3
2
SYM.
3
8
6
6
G
1
3
1
6
3
3
2
1
S
2
7
6
5
2
F
1
5
2
5
3
1
2
6
R
2
6
4
3
5
E
3
6
M
D
1
4
5
3
1
6
2
5
3
L
2
3
5
2
5
C
1
1
6
2
4
6
K
2
3
4
2
B
1
3
J
2
3
CIRCUIT DIAGRAM
1
6
A
2
CIRCUIT
DESIGNATES MOMENTARY CIRCUITS
DESIGNATES TWO POSITION CONNECTION
2
5
DESIGNATES EXTERNAL JUMPER PROVIDED
BY CUSTOMER
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura II to XIV - Circuit Diagram | 9
LAMP
CIRCUIT
CIRCUIT DIAGRAM
LAMP
CIRCUIT
+8
+8
A/1
F/6
1
G/7
2
M/R
2
J/8
+1 +3 -4
SPECIAL
#3
+6
1
2
N/T
+8
-6
2
1
SPECIAL
#4
1
+3
2
-7
+3
+6
1
-7
2
-7
-8
2
+1 +3 -4
P/V
2
-6
1
2
-7
+8
+1 +3
1
2
K/W
CIRCUIT DIAGRAM
1
U/Y
2
(-)7
CIRCUIT DIAGRAM
3
1
+6
1
-7
3
17 18 10(-)
J1
1
1
2
5
2
3 14
3 14
5
CIRCUIT DIAGRAM
CIRCUIT
CIRCUIT
10(-)
J5
J5
1
3
5
1
3
5
3
1
6 16
6 16
JK
8
17 18 10(-)
SYMBOL LEGEND
SYM.
SYMBOL
LEGENDDEFINITION
1
1
J4
5
5
3 14 15 12
8
J4
2
3 14 15 12
3 14
JK
17 18 10(-)
3
11 13
1311
1
1
5
3 14
JJ
17 18 10(-)
5
NOTE:
J circuits are available for
all non-locking V-Series
styles. Consult factory for
p /n details.
6
11 13
13 11
8
J3
3
6
3 14
JJ
1
2
3 14
5
8
17 18 10(-)
5
-9
8
J3
2
-7
8
5
1
5
2
JA
1
J2
1
JA
17 18 10(-)
J2
+10
CIRCUIT DIAGRAM
13 11
2
+8
CIRCUIT DIAGRAM
11 13
17 18
2
2
17 18 10(-)
CIRCUIT
17 18
3
2
8
8
CIRCUIT
CIRCUIT DIAGRAM
10(-) 1
17 18 10(-)
J1
2
2
-7
1
+6
1
+8
-6
+3
2
+1 +3
1
SPECIAL
#1
+3
H/Z
-7
13 11
+3
1
+8
C/3
11 13
L/9
CIRCUIT DIAGRAM
-6
-7
+3
CIRCUIT
+3
LAMP
CIRCUIT
-7
1
-7
CIRCUIT
-6
2
+8
1
E/5
CIRCUIT DIAGRAM
-7
+3
D/4
+3
1
-7
B/2
LAMP
CIRCUIT
CIRCUIT DIAGRAM
SYM.
CIRCUIT
DESIGNATES TERMINALS AND CONTACTS
DEFINITION
DESIGNATES LAMP LOCATION
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
JA,JJ,JK
J1,J3,J4,J5
J2
CONNECTOR PART #
JC1-01
JC2-01
JC3-01
DESIGNATES TWO POSITION CIRCUIT
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
10 | V-Series Contura II & III Sealed Rocker Switches - Ordering Scheme
V 1 D A B T 0 B
1
Series
2
Circuit
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
A R B 00
8
Bracket
9
Actuator
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
Position:
0 00
13
14
Legend
Actuator
Orientation Lens Legend
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
5 ILLUMINATION
3,6
Actuator orientation above terminals:
1,4
10 LENS
0 - No Actuator Z - No Lens
ClearWhite Amber Green
1
6
8
G
2
7
C
H
3
8
D
J
4
9
E
K
5
A
F
L
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
Gray
G
H
0
No Actuator
A, B Contura II
C, D Contura III
3 RATING
4 TERMINATION/BASE STYLE
White
W
Y
9 ACTUATOR
3
1
B
C
D
E
F
M
N
12
Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
11
Color
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
V
10
Lens
Red
M
N
P
R
S
Blue
T
U
V
W
Y Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR COLOR1 AND TEXTURE
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
A
1
1
INDEPENDENT 8 (+) 7 (–)
B
2
1
DOWN 3 (+) 7 (–)
C
3
2
UP 3 (+) 7 (–)
D
4
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
5
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
6
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
7
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
U
Y
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J8
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
KW
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L9
1
DOWN
3 (+) 6 (–)
MR
1
UP
3 (+) 6 (–)
NT
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
PV
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
0 - No Actuator
BlackGray Red
White
Soft Surface
BGRW
Hard Surface
CHSY
12 ACTUATOR LENS OR BODY LEGENDS2
11ON 12 OFF 13 I
14O
OFF ONO I
15 O O 16 O O
F N N F
FF
17 O I
18 I O
For additional legend options & codes, visit us at www.carlingtech.com.
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Body legends not available on Soft surface actuators; White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
4 Contura II available with two square lenses. Consult factory for details.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura II & III Locking Sealed Rocker Switches - Ordering Scheme | 11
V 1 D A S W 0 B
1
Series
2
Circuit
4
5
6
Termination Illumination Lock
3
Rating
7
Lamp
1 SERIES
V
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
11
Function
0
12
Legend
13
Legend
Orientation
3 RATING
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
White
W
Y
Gray
G
H
9 HARD SURFACE ACTUATOR1
Contura II
BlackGray Red White
A BGH
Contura III
C DEF
3,6
Actuator orientation above terminals:
1,4
10 LENS
Z - No Lens
ClearWhite Amber Green Red Blue
3
8
D
J
P
V
4
1
B
C
D
E
F
M
N
10
Lens
Lamp above terminals 3 & 6 end of switch
Position:
9
Actuator
7 LAMP
2 CIRCUIT
A Z E 00
8
Bracket
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR LOCK FUNCTION AND COLOR1
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
C
3
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
MR
1
UP
3 (+) 6 (–)
6 LOCK
Lock above terminals 1 & 4 end of switch.
Wlock
Lock Color Match Actuator
Black White Red
Safety Orange
Up
Down
Up & Down Center3
A
HR1
BJ S2
CKT 3
DL V4
E M W5
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21
22
OFF ON
25 O
F
F
23
26 O
N
O
27 O
24
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 21-28 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION 1
ORIENTATION 4
AZC45-1
45
ORIENTATION 2
AZC45-2
45
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory.
3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function.
4 Additional ratings available. See V-Series Switch Accessories page.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
ORIENTATION 3
12 | V-Series Contura IV Sealed Rocker Switches - Ordering Scheme
V 1 D A B T 0 B
1
Series
2
Circuit
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
E P C 00
8
Bracket
9
Actuator
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
13
14
Legend
Actuator
Orientation Lens Legend
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Gray
G
H
1,4
Actuator orientation above terminals:
3,6
No Actuator
Contura IV, left orientation
Contura IV, left orientation, laser etched
Contura IV, right orientation
Contura IV, right orientation, laser etched
10 LENS
0 - No Actuator Z - No Lens
ClearWhite Amber Green
1
6
8
G
2
7
C
H
3
8
D
J
4
9
E
K
5
A
F
L
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
White
W
Y
9 ACTUATOR
0
E
T
F
R
3 RATING4
1
B
C
D
E
F
M
N
0 00
12
Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Position:
11
Color
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
V
10
Lens
Red
M
N
P
R
S
Blue
T
U
V
W
Y EF
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
A
1
1
INDEPENDENT 8 (+) 7 (–)
B
2
1
DOWN 3 (+) 7 (–)
C
3
2
UP 3 (+) 7 (–)
D
4
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
5
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
6
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
7
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
U
Y
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J8
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
KW
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L9
1
DOWN
3 (+) 6 (–)
MR
1
UP
3 (+) 6 (–)
NT
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
PV
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
11 ACTUATOR COLOR1,5,6
No Actuator 0
Black C
Gray H
Red S
White Y
Nickel D
Pewter E
12 ACTUATOR LENS OR BODY LEGENDS2
11ON 12 OFF 13 I
14O
OFF ONO I
15 O O 16 O O
F N N F
FF
17 O I
18 I O
For additional legend options & codes, visit us at www.carlingtech.com.
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION 1
ORIENTATION 4
E8C45-100
E3C70-200
F8C45-100
F3C70-200
ORIENTATION 2
E8C45-300
F8C45-300
ORIENTATION 3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory.
3 Gloss brow is on left side of E actuator and right side of F actuator.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Laser etched rocker only available with lens code Z & actuator colors black,
nickel or pewter.
6 Pewter and nickel colors only available with laser etched actuator.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura V Sealed Rocker Switches - Ordering Scheme | 13
V 1 D A B T 0 B
1
Series
2
Circuit
3
Rating
4
5
6
Termination Illumination Lamp
7
Lamp
G P C 00
8
Bracket
9
Actuator
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
0 00
13
14
Legend
Actuator
Orientation Lens Legend
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
0
G
P
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Gray
G
H
No Actuator
Contura V
Contura V, laser etched
10 Lens
0 - No Actuator Z - No Lens
ClearWhite Amber Green Red
1
6
8
G
M
2
7
C
H
N
3
8
D
J
P
4
9
E
K
R
5
A
F
L
S
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
White
W
Y
9 ACTUATOR
3 RATING4
1
B
C
D
E
F
M
N
12
Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Position:
11
Color
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
V
10
Lens
Blue
T
U
V
W
Y
bar
bar/bar
oval
oval/bar
oval/oval
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR COLOR1,3,3
No Actuator 0
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
A
1
1
INDEPENDENT 8 (+) 7 (–)
B
2
1
DOWN 3 (+) 7 (–)
C
3
2
UP 3 (+) 7 (–)
D
4
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
5
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
6
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
7
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
U
Y
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J8
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
KW
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L9
1
DOWN
3 (+) 6 (–)
MR
1
UP
3 (+) 6 (–)
NT
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
PV
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
Black C
Gray H
Red S
White Y
Nickel D
Pewter E
12 ACTUATOR LENS OR BODY LEGENDS2,6
11ON 12 OFF 13 I
14O
OFF ONO I
15 O O 16 O O
F N N F
FF
17 O I
18 I O
For additional legend options & codes, visit us at www.carlingtech.com.
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
4G13L
4G
MC
MA
MA3MC
MA
4G
MC
3L
4G200
MA1MC
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 1
ORIENTATION 4
ORIENTATION 2
ORIENTATION 3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on
white, red and gray actuators. Custom colors are available, consult factory.
3 Laser Etched rocker only available with lens code Z & actuator colors black,
nickel or pewter.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Nickel and Pewter colors only available with laser etched actuator.
6 Consult factory for laser etched lens callout.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
14 | V-Series Contura IV & V Locking Sealed Rocker Switches - Ordering Scheme
V 1 D A S W 0 B
4
5
6
Termination Illumination Lock
3
Rating
7
Lamp
1 SERIES
V
2
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
ONNONE OFF
ONNONE ON
ONOFF ON
ONOFF (ON)
(ON)OFF (ON)
OFFNONE ON
11
Function
0
12
Legend
13
Legend
Orientation
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
White
W
Y
Gray
G
H
9 HARD SURFACE ACTUATOR
3 RATING4
1
B
C
D
E
F
M
N
10
Lens
Lamp above terminals 3 & 6 end of switch
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
SPDP
1A
4D
6J
7K
8L
9N
9
Actuator
7 LAMP
CIRCUIT3
Position:
J Z E 00
8
Bracket
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
C
3
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
MR
1
UP
3 (+) 6 (–)
BlackGray Red White
J KL M
NPR S
CONTURA V:
Orientation
BlackGray Red White
UV WY
Actuator orientation above terminals: 3,6
1,4
Actuator orientation above terminals: 3,6
1,4
10 LENS5
Z - No Lens
ClearWhite Amber Green Red Blue
A
B
C
D
E
F bar lens
G
H
J
K
L
M oval lens
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR LOCK FUNCTION AND COLOR1
Lock Color Match Actuator
Black White Red
Safety Orange
Gray
Up
Down
Up & Down Center3
A
HR1
BJ S2
CKT 3
DL V4
E M W5
F GN6
12 ACTUATOR LENS OR BODY LEGEND2
6 LOCK
Lock above terminals 1 & 4 end of switch.
W
low profile lock
CONTURA IV:
Orientation
Left
Right
Y6
high profile lock
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory.
3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Located at T3-6 end of switch.
6 Contura V style only.
00 - No Legend
21
22
OFF ON
25 O
F
F
26 O
N
23
O
27 O
24
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
0
1
2
3
4
ORIENTATION 1
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
JHAY3-100
JHAY3-200
JHAY3-300
ORIENTATION 2
2
Circuit
ORIENTATION 4
1
Series
P
P
P
P
P
P
NHAY3-100
NHAY3-200
NHAY3-300
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
ORIENTATION 3
V-Series Contura VI WAVE Sealed Rocker Switches - Ordering Scheme | 15
V 1 D B G N T B
2
Circuit
3
Rating
4
5
6
Termination Illumination Lamp
8
Bracket
7
Lamp
H A 7 C B AC
9
Actuator
1 SERIES
V
13
Insert
Color
1 00
14
Actuator
Lens
15
16
Legend
Actuator
Orientation Lens Legend
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
0
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Gray
G
H
H High Insert
No Actuator
L
Low Insert
10,11 LENS4
0 - No Actuator Z - No Lens
ClearWhite Amber Green
–
7
C
H
3
–
D
J
4
–
E
K
–
A
F
L
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
White
W
Y
9 ACTUATOR
3 RATING3
1
B
C
D
E
F
M
N
12
Color
Lamp above terminals 3 & 6 end of switch
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
Position:
11
Lens
7 LAMP
2 CIRCUIT
10
Lens
Red
N
P
R
S
Blue
U
V
W
Y
Bar Lens Translucent
Bar Lens Transparent
Oval Lens Transparent
Oval Lens Translucent
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
12 ACTUATOR COLOR
C
Jumper
No
No
Yes T2 to 5
No
No
No
No
S
Gray
Red
13 INSERT COLOR
B
C
D
Y
White
N Bright Nickel Plated
S Satin Chrome Plated
T Satin Nickel Plated
W White
Black
Bright Chrome Plated
Satin Chrome Painted
14 ACTUATOR LENS OR BODY LEGENDS2
00 - No Legend this location/No actuator
11ON 12 OFF 13 I
14O
OFF ONO I
15 O O 16 O O
F N N F
FF
17 O I
18 I O
For additional legend options & codes, visit us at www.carlingtech.com.
Orientation
1
15 LEGEND ORIENTATION
0
1
2
3
4
VTHAACN-MC1MC
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
VTHA7CN-3M100
VTHWZCB-45146
VTLSZSC-70100
Orientation
2
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
A
1
1
INDEPENDENT 8 (+) 7 (–)
B
2
1
DOWN 3 (+) 7 (–)
C
3
2
UP 3 (+) 7 (–)
D
4
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
5
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
6
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
7
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
U
Y
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J8
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
KW
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L9
1
DOWN
3 (+) 6 (–)
MR
1
UP
3 (+) 6 (–)
NT
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
PV
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
H
Black
Orientation
4
1
Series
VTLLFHC-A813H
VTLDECC-001MG
Orientation
3
16 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators. Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
16 | V-Series Contura VII Sealed Rocker Switches - Ordering Scheme
V 1 D A B T 0 B
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
Z R C 00
8
Bracket
9
Actuator
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
0
Z
1,4
10 LENS
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
0 - No Actuator
Z - No Lens
White Amber
Green
Red
Blue Lens style & location
6 B
G
MT
7 C
H
NU
8 D
J
PV
9 E
K
RW
A F
L
SY
1 2
3
45
11 ACTUATOR COLOR/THUMB PRINT COLOR1
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
A
1
1
INDEPENDENT 8 (+) 7 (–)
B
2
1
DOWN 3 (+) 7 (–)
C
3
2
UP 3 (+) 7 (–)
D
4
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
5
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
6
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
7
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
U
Y
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J8
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
KW
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L9
1
DOWN
3 (+) 6 (–)
MR
1
UP
3 (+) 6 (–)
NT
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
PV
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
3,6
O N/A - No Actuator
HGrey/Black
YWhite/Black
CBlack/Black
SRed/Black
ORIENTATION 4
5 ILLUMINATION & SWITCH SEALING
No Actuator
Contura VII
ORIENTATION 2
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
ACTUATOR
ORENTATION
ABOVE TERMINALS
STANDARD
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
Gray
G
H
9 ACTUATOR
3 RATING4
1
B
C
D
E
F
M
N
White
W
Y
14 ACTUATOR LENS OR BODY LEGENDS2
11ON 12 OFF 13 I
14O
OFF ONO I
15 O O 16 O O
F N N F
FF
17 O I
18 I O
For additional legend options & codes, visit us at www.carlingtech.com.
ORIENTATION 1
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
AA
46
46
3AA-146
ORIENTATION 3
2
ORIENTATION 2
1
ORIENTATION 1
( ) - momentary
ORIENTATION 4
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
ORIENTATION 4
13
14
Legend
Actuator
Orientation Lens Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Position:
0 00
12
Legend
ORIENTATION 1
11
Color
6,7 LAMP (same coding for both selections)
1 SERIES
V
10
Lens
ORIENTATION 2
2
Circuit
ORIENTATION 3
1
Series
AA
3AA-246
ORIENTATION 3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators. Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
4 Legends available for lighted oval lens version only
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura X, XI & XII Sealed Rocker Switches - Ordering Scheme | 17
V 1 D A B 6 0 1
2
Circuit
3
Rating
4
5
6
Termination Illumination Lamp
7
Lamp
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
3 RATING4
1
B
C
D
E
F
M
N
10
Lens
11
Lens
0 00
12
Legend
13
14
Legend
Actuator
Orientation Lens Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Position:
9
Actuator
6,7 LAMP (same coding for both selections)
1 SERIES
V
6 P Z 00
8
Bracket
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Jumper
No
No
Yes T2 to 5
No
No
No
No
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET)
X & XI w/Flush Bracket
# of gaskets0
1
2
Black
B
C
D
White
WY Z
Gray
GH J
9 ACTUATOR
No Actuator Contura X
Contura XI
Contura XII
X, XI, XII w/Raised Bracket
0
1
1
4
2
5
3
6
0
Black Gray WhiteRed
1 23 4
6 78 9
J
K
N
M
3,6
Actuator orientation above terminals:
1,4
10 LENS - ABOVE LAMP #1 TERMINALS1,4
11 LENS - ABOVE LAMP #2 TERMINALS3,6
0 - No Actuator
Z - No Lens
Clear White Amber Green Red
Blue Lens Style
38 D J P VBar
49 E K R WOne piece Square
5AF L S YTwo piece Square*
(w/ clear top protective lens)
27CHNUTwo piece Square*
(w/ smoke top protective lens)
16 B G M TTwo piece Square*
(w/ white top protective lens)
* All bottom lenses are molded of opaque material. Consult factory for other lens colors.
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend this location/No actuator
11 ON 12 OFF
13 I
14 O
OFF ON
O
I
15 O O 16 O O 17 O I 18 I O
F N
N F
F
F
21
22
23
24
OFF ON
O
I
25 O
F
F
26 O
N
27 O
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
13 LEGEND ORIENTATION3
0
1
2
3
4
ORIENTATION OF
ACTUATOR/LENS IN PANEL
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
6ZZ3G-100
6FFMA-4MC
MA
3G
ORIENTATION 1
ORIENTATION 2
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
A
1
1
INDEPENDENT 8 (+) 7 (–)
B
2
1
DOWN 3 (+) 7 (–)
C
3
2
UP 3 (+) 7 (–)
D
4
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
5
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
6
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
7
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
U
Y
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J8
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
KW
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L9
1
DOWN
3 (+) 6 (–)
MR
1
UP
3 (+) 6 (–)
NT
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
PV
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white, red & gray actuators. Custom colors are available, consult factory.
3 With 2 square lenses, use sel. 12 for lens above lamp 1, & selection 14 for lens above lamp 2.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Not available with Contura XI rockers.
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
ORIENTATION 4
1
Series
70
G3
A7
MC
6ZZ3G-1A7
MA
6FFMA-3MC
MC
6FZ70-100
14 ACTUATOR LENS LEGEND
ORIENTATION 3
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
18 | V-Series Contura X Locking Sealed Rocker Switches - Ordering Scheme
V 1 D A S W 0 1
1
Series
2
Circuit
4
5
6
Termination Illumination Lock
3
Rating
7
Lamp
1 SERIES
V
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
4D
ONNONE ON
6J
ONOFF ON
9N
OFFNONE ON
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
S*
2 & 3, 5 & 6
2 & 3
1&2
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
3 RATING4
1
B
C
D
E
F
M
N
9
Actuator
10
Lens
11
Function
12
Legend
13
Legend
Orientation
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
Position:
8
Bracket
0
6,7 LAMP (same coding for both selections)
2 CIRCUIT
1 P B 00
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
C
3
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
MR
1
UP
3 (+) 6 (–)
6 LOCK
Lock above terminals 1 & 4 end of switch.
Wlock
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators; Custom colors are available, consult factory.
3 Located over T1-4 end of switch.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Located over T3-6 end of switch.
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No Gasket1
One Gasket4
White
2
5
Gray
3
6
9 HARD SURFACE ACTUATOR
Black
1
Contura X
Grey
2
Red
3
White
4
Actuator orientation above terminals: 3,6
1,4
10 LENS - ABOVE LAMP #2 TERMINALS5
Z - No Lens
Clear White Amber Green Red
Blue Lens Style
38 D J P VBar
49 E K R WOne piece Square
5AF L S YTwo piece Square*
(w/ clear top protective lens)
27CHNUTwo piece Square*
(w/ smoke top protective lens)
16 B G M TTwo piece Square*
(w/ white top protective lens)
* All bottom lenses are molded of opaque material. Consult factory for other lens colors.
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR LOCK FUNCTION AND COLOR3
Lock Color Match Actuator
Black White Red
Gray
Safety Orange
Up
Down
Up & Down
A
HR
BJ S
CKT
DL V
E MW
F NY
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21
22
OFF ON
25 O
F
F
26 O
N
23
24
O
27 O
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
13 LEGEND ORIENTATION3
0
1
2
3
4
Orientation 1
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
Orientation
Orientation
2
4
1PM4F-1
45
4F
MC
18K45-2
13DMC-1
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Orientation 3
V-Series Contura XIV Sealed Rocker Switches - Ordering Scheme | 19
V 1 D B B C 0 B
1
Series
2
Circuit
3
Rating
4
5
6
Termination Illumination Lamp
7
Lamp
FA P C AB
8
Bracket
9
Actuator
1 SERIES
V
2 CIRCUIT
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
Position:
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
2
3
Color No Gasket
BlackB
GrayG
White
W
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
34
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
1 Gasket
2 Gasket
C
D
H
J
YZ
9 ACTUATOR STYLE
0
FA FB
No Actuator - Furnished separately
Contura XIV
Contura XIV - Laser Etched
10 LENS COLOR / STYLE
0 - No Actuator Z - No Lens
ClearWhite Amber Green
1
6
B
G
2
7
C
H
3
8
D
J
4
9
E
K
5
A
F
L
5
A
N/A
N/A .4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
5 ILLUMINATION
13
14
Legend
Actuator,
Orientation Lens Legends
8 BRACKET COLOR & PANEL SEAL
3 RATING3
4 TERMINATION / BASE STYLE
12
Legend
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2 & 3
OFF
M*
(2 & 3, 5 & 6)
2 & 3
OFF
R*
(2 & 3, 5 & 6)
2 & 3
2&1
E*
5 & 6
5 & 3
5&1
S*
2 & 3, 5 & 6
2 & 3
1&2
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
1
B
C
D
E
F
11
Actuator
Color
6 & 7 LAMP
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
( ) - momentary
1
10
Lens
1 00
Red
M
N
P
R
S
N/A Blue
T
U
V
W
Y
N/A PAD Printed
Laser-Etched
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Lamps
Illumination Type Lamp wired to Terminals
S
NONE –
–
A
1
INDEPENDENT 8 (+) 7 (–)
B
1
DOWN 3 (+) 7 (–)
C
2
UP 3 (+) 7 (–)
D
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
2
INDEPENDENT 8 (+) 7 (–)
SINGLE POLE SWITCHES ONLY
J
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
K
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L
1
DOWN
3 (+) 6 (–)
M
1
UP
3 (+) 6 (–)
N
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
P
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
U
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
11 ACTUATOR COLOR1
O N/A - No Actuator
CBlack
SRed
YWhite
12 ACTUATOR LENS or BODY LEGEND2
00 - No Legend this location/No actuator
11ON 12 OFF 13 I
14O
OFF ONO I
15 O O 16 O O
F N N F
FF
17 O I
18 I O
13 LEGEND ORIENTATION
0
1
2
3
4
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
1
2
3
4
14 ACTUATOR / LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators.
3 Additional ratings available. See V-Series Switch Accessories page.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
20 | V-Series Contura Sealed Rocker Switch Actuators Separately
Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Contura VI Actuator with lenses and inserts only: VV with code selections 9-16
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Panel Seal: VPS
Contura X & XI actuators without lenses separately:
VVR 6 1 00 1
1
Actuator Separately
4
Actuator
Legend
2
3
Actuator
Lens
Style/Color Opening
5
Legend
Orientation
2 ACTUATOR STYLE & COLOR
Black
1
6
Gray
2
7
3 LENS OPENING FOR1
1
2
3
4
15 O O 16 O O
F N
N F
F
F
17 O I
J Black
Z No lens
square lens on top/
bar lens on bottom
(Contura X only)
6
7
Legend
Legend
Orientation
5
Legend
N White
1 Bar lens
00 - No Legend
21
OFF
22
25 O
F
F
26 O
N
M Red
2 Square lens
5, 7 LENS OR BODY LEGEND2
14 O
I
23
ON
O
27 O
24
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
18 I O
ORIENTATION OF
ACTUATOR/LENS IN PANEL
6 LEGEND ORIENTATION3
0 No legend
1 Orientation 1
2 Orientation 2
ORIENTATION OF
ACTUATOR/LENS IN PANEL
5 LEGEND ORIENTATION1
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
K Gray
3,4 LENS OPENING FOR
For additional legend options & codes, visit us at www.carlingtech.com.
0
1
2
3
4
4
Lens
Opening
3
Lens
Opening
2 ACTUATOR STYLE & COLOR
Red
4
9
4 ACTUATOR LENS OR BODY LEGEND
00 - No Legend this location
11 ON 12 OFF
13 I
OFF ON
O
2
Style &
Color
1 CONTURA XII ACTUATOR SEPARATELY
VVP
White
3
8
5
One bar lens
One bar lenses
One square lens
two square lens
VVP J 1 Z 21 1 00
1
Actuator
1 CONTURA X & XI ACTUATOR SEPARATELY
VVP
Contura X
Contura XI
Contura XII actuators without lenses separately:
ORIENTATION 2
Contura X, XI & XII actuator lens assembly separately:
ORIENTATION 1
ORIENTATION 4
ORIENTATION 1
VVL 2 1 00 0
ORIENTATION 2
1
Lens Separately
ORIENTATION 3
2
Lens
Style
4
Legend
3
Lens
Color
5
Legend
Orientation
1 CONTURA X, XI & XII LENS SEPARATELY
VVL
Contura X, XI & XII top piece of 2-piece lens separately:
VVT 1
1
Lens Separately
1 TOP OF LENS SEPARATELY
VVT
1 Clear
2 Smoke
3 White
Contura X, XI & XII actuator lens assembly:
top lens
actuator stem
posts mount toward actuator stem
bottom lens
}
two piece
lens assembly
1 piece lens/bar lens are positioned the same as bottom lens for assembly,
minus the top lens. Lenses snap in from bottom.
Notes:
1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2
must be chosen.
2 Center of actuator marking not available for Contura XII.
3 Legend is not available for bar style lens.
4 Not recommended with neon lamps.
5 Must also order top piece of 2 piece square lens separately.
2 One Piece Square lens
3 Bottom of Two-Piece Square lens5
3 TRANSLUCENT LENS COLOR
1 Clear
2 COLOR
2
Color
2 LENS STYLE3
1 Bar lens
2 White
3 Amber
4 Green4
4 LENS OR BODY LEGEND2
00 - No Legend
21
OFF
22
25 O
F
F
26 O
N
ON
23
5 Red
O
27 O
24
6 Blue4
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
ORIENTATION OF
ACTUATOR/LENS IN PANEL
5 LEGEND ORIENTATION3
0
1
2
3
4
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION 1
ORIENTATION 4
ORIENTATION 2
ORIENTATION 3
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura Sealed Rocker Switch Accessories | 21
Easily integrate Contura products into your system, with Contura Accessories
Q.C. SELECTION GUIDE
Contura ConnectorsPART NO
COMPANY
SERIES
WIRE
RANGE
Q.C.
SELECTION
TIN GUIDE
PLAIN
COMPANY
SERIES
ORIENTATION
MM 2
AWG
WIRE
RANGE
PLATED
BRASS
BRASS
PART NO
(REF)
12
3.0 ORIENTIN
2
TATION
PLAIN
02965471
AWG(2)16-14
PLATED
Q.C.
SELECTION
Q.C.12010601
SELECTION
GUIDE
Q.C.
SELECTION
GUIDE MM(2)1.0-2.0
GUIDE
BRASS
02965470BRASS
16-14 (REF) 1.0-2.0
02965580
PACKARD
58 SERIES
B
WIRE
WIRE
WIRE
PART
NO
PART
NO RANGE
PART 20-18
NO RANGE
02965580
12
3.0
02965469
06288318
.5-.8 RANGE
COMPANY
COMPANY
ORIENORIENORIEN12010601
02965471 COMPANY
(2)16-14 102TIN
(2)1.0-2.0
TIN
TIN
5.0
2
12084590
PLAIN
PLAIN
PLAIN
SERIES
SERIES
SERIES
TATION
TATION
TATION
AWG
MM
AWG
MM
AWG
MM 2
PACKARD
PLATED
PLATED
Q.C.
SELECTION
GUIDE
BRASS
BRASS
BRASS
TANG
02965470 PLATED
16-14
1.0-2.0(REF)
B (REF)
12
3.0
(REF)
BRASS 12052224
BRASS
BRASS
58 SERIES
WIRE
02965469 02965580
06288318
20-18 3.0
.5-.8 3.0
02965580
1202965580
12
12
3.0
PART
NO12015870
16-14
1.0-2.0
RANGE
PACKARD
12010601
12010601
120106015.0(2)1.0-2.0
02965471
(2)16-14
(2)16-14
(2)16-14
(2)1.0-2.0
02965471
02965471
COMPANY
ORIEN10(2)1.0-2.0
12084590
Q.C. 12020035
SELECTION
GUIDE
(2)22-18
(2).5-.8
A
METRI-PACK
TIN
PACKARD
PACKARD
PACKARD
2
SERIES
TATION
TANG
B1.0-2.0
B
02965470 PLAIN
02965470
16-14
02965470
16-14 MM
16-14
AWG
PLATED
12 1.0-2.0
3.0 B1.0-2.0
SERIES58
58630
SERIES
SERIES BRASS
58 12052224
SERIES
WIRE
12015869
20-18
.5-.8
12015832
(REF)
BRASS
PART
NO20-18
02965469
06288318
02965469
06288318
02965469 .5-.8
20-18
06288318
.5-.8
20-18
.5-.8
RANGE
12015870
16-14
1.0-2.0
12 5.0
PACKARD
COMPANY 02965580
20-22
.35-.5
10
10 3.0
5.0
10ORIEN5.0
12084590 12052222
12084590
12084590
TIN
TANG SYMBOL
=
SHOWS ORIENTATION OF TANG IN SLOT
PLAIN
SERIES 02965471
METRI-PACK
12020035
(2)22-18
(2).5-.82 12TATIONA 3.0
12010601
(2)16-14
TANG
TANG
TANG
AWG
12052224
12052224
12052224
12
3.0
12(2)1.0-2.0MM 3.0
PLATED
16-12
1.3-3
BRASS
630 SERIES PACKARD
(REF)
SYMBOL
B
02965470
16-14
1.0-2.0
BRASS
60253-2
60253-1
12015832
12015869
20-18
.5-.8
58
SERIES
12015870
12015870
12015870
16-14
1.0-2.0
16-14
1.0-2.0
16-14
1.0-2.0
AMP
PACKARD
PACKARD 02965469
PACKARD
(2)
16
(2)
1.3
20-18 12
.5-.8 3.0
02965580 06288318
250 SERIES
(2)22-18
(2)22-18
A(2).5-.8B
A
12020035
12020035
12020035
METRI-PACK
METRI-PACK
METRI-PACK
12052222(2)22-18
20-22(2).5-.8
.35-.5A(2).5-.8
TANG SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
12010601
(2)1.0-2.0 .8-2
02965471
10 (2)16-14
5.0
12084590
630 SERIES
630
SERIES
630
SERIES
42100-2
18-14
FASTIN-FASTON
42100-1
12015869
12015869
12015869
20-18
.5-.8
20-18
.5-.8
20-18
.5-.8 TANG
12015832
12015832
12015832
PACKARD
16-12
1.3-3
12 16-14
3.0
B
02965470 12052224
1.0-2.0
SYMBOL
58
SERIES
60253-1
60253-2
20-22
.35-.5
20-22
.35-.5
20-22
.35-.5
12052222
12052222
12052222
60295-2
22-18
.3-.9
60295-1
AMP
TANG
SYMBOL
=
TANG
SYMBOL
=
TANG
SYMBOL
=
SHOWS
ORIENTATION
SHOWS
OFORIENTATION
TANG
IN
SHOWS
SLOT
OFORIENTATION
TANG IN SLOT
OF TANG IN SLOT
12015870
16-14
1.0-2.0
02965469
06288318 (2) 16
20-18
(2) .5-.8
1.3
PACKARD
250 SERIESMETRI-PACK
16-12 (2)22-18
1.3-3
16-12(2).5-.8 1.3-3
16-12
B 1.3-3
A
12020035
SYMBOL
SYMBOL
SYMBOL
10
5.0 and availability.
12084590
60253-2
60253-2
60253-2
60253-1
60253-1
60253-1
AMPConsult
AMP
AMP
FASTIN-FASTON
42100-1
18-14
.8-2
42100-2
NOTE:
Delphi
Packard
and/or
Amp
on
actual
part
numbers
630 SERIES
(2)
16
(2)
1.3
(2)
16
(2)
1.3
(2)
16
(2)
1.3
TANG
12015869
20-18 12
3.0 B
250 SERIES
SERIES 12015832
250 SERIES
B
B
AMP is 250
a registered
trademark
of12052224
AMP Inc.
Harrisburg,.5-.8
PA
60295-1 FASTIN-FASTON
60295-2
22-18
.3-.9
18-14
.8-218-14
.8-2
42100-2
42100-2
42100-2
FASTIN-FASTON FASTIN-FASTON
42100-1
42100-1
42100-1
20-2216-14
.35-.5
12052222
12015870
1.0-2.0.8-218-14
Delphi Packard
Warren,
Ohio SHOWS ORIENTATION OF TANG IN SLOT
TANG
SYMBOL =
PACKARDis a registered trademark of Delphi-Packard Electrical Systems
22-18
.3-.9
22-18
22-18 A
.3-.9
60295-2
60295-2
60295-2
60295-1
60295-1 12020035
60295-1
16-12
1.3-3(2).5-.8.3-.9
(2)22-18
METRI-PACK
SYMBOL
60253-1 Amp60253-2
NOTE: Consult Delphi
on actual part numbers and availability.
AMP
630Packard
SERIES and/or
12015869 (2) 1620-18 (2) 1.3 .5-.8
12015832
.820[20.83]
250
SERIES
NOTE:
Consult
NOTE:
Packard
Consult
and/or
Delphi
NOTE:
Amp
Packard
Consult
onAMP
actual
and/or
Delphi
partAmp
numbers
Packard
on actual
and/or
and part
availability.
numbers
on actual
and part
availability.
numbers
and
availability.
AMP
is aDelphi
registered
trademark
of
Inc.
Harrisburg,
PAAmp
B
18-14
.8-2
FASTIN-FASTON
42100-1
20-22of AMP
.35-.5
12052222
AMP isPackard
a registered
AMP
trademark
is a registered
of AMP
AMP
trademark
Inc.
is42100-2
Harrisburg,
a registered
of AMP
PA
trademark
Inc.
Harrisburg,
PAInc.
Harrisburg,
PA Warren, TANG
Delphi
is.820[20.83]
a registered
trademark
of
Delphi-Packard
Electrical
Systems
Ohio SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
Delphi Packard is Delphi
a registered
Packard
trademark
is Delphi
a registered
of
Packard
Delphi-Packard
trademark
is a registered
of
Electrical
Delphi-Packard
trademark
Systems
of
Electrical
Warren,
Delphi-Packard
Systems
Ohio
Electrical
Warren, Ohio
Systems Warren, Ohio
22-18
.3-.91.3-3
60295-2
60295-1
16-12
SYMBOL
60253-2
60253-1
AMP
(2) 16 and availability.
(2) 1.3
NOTE: Consult
Delphi Packard and/or Amp on actual part numbers
250 SERIES
.820[20.83] .820[20.83]
B .820[20.83]
.820[20.83]
.820[20.83]
.820[20.83]
.820[20.83]
AMP is a registered
trademark
Inc. Harrisburg,
PA
18-14
.8-2
42100-2
FASTIN-FASTON
42100-1 of AMP
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
22-18
.3-.9
60295-2
60295-1
.820[20.83]
.770[19.56]
.820[20.83]
NOTE: Consult.820[20.83]
Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
.920[23.37]
A
.920[23.37]
A
.920[23.37]
A
PACKARD 630
PACKARD 630
A B
.820[20.83]
VC1
B
VC1
PACKARD 630
A
.920[23.37]
B
A
AMP,
58 AMP, PACKARD 58
AMP, PACKARD
58
PACKARD
630 PACKARD
PACKARD 630
VC1
VC1
B
B
.920[23.37]
.920[23.37]
A
A
PACKARD
630
PACKARDPACKARD
630
630
VC1
VC1
VC1
PACKARD 630
VC1
VC1
B
B
A
A
AMP,
58
AMP, PACKARD
AMP, PACKARD
58 630
58 PACKARD
AMP, PACKARD
58
PACKARD
B
.920[23.37]
A
PACKARD 630
VC2
B
A
VC1
B
.820[20.83]
.920[23.37]
.920[23.37]
VC2
AMPAMP, PACKARD 58
PACKARD 630
AMP, PACKARD 58
VC2
A
VC2
AMP,1.266[32.16]
PACKARD 58
1.266[32.16]
1.466[37.24]
10 3A 1.266[32.16]
2 1 8
7 41.466[37.24]
5 1.466[37.24]
69
A
1.266[32.16]
AMP, PACKARD 58
10 3
2 1 8
7 4
5
69
AMP
5
AMP
679
A
VC2
B AMP PACKARD 630
58
VC2
AMP, PACKARD
4
73 45
2
A
VC2
PACKARD 630
69
15 8 6
9
A
1.170[29.72]
.770[19.56]
PACKARD 630
.950[24.13]
A
B
.770[19.56]
B
PACKARD 630
2 VC21 8
7 4
5
69
B
58AMP, PACKARD
.950[24.13]
1 87 4 5
3 4 235 1 62 8
B
AMP
AMP
AMP,
PACKARD 58
AMP,
PACKARD 58
1.250[31.75]
1.250[31.75]
1.266[32.16]
1.466[37.24]
1.266[32.16]
1.466[37.24]
1.466[37.24]
10 3 2 11.266[32.16]
81.266[32.16]
7 4 5 6 9 1.466[37.24] 1.466[37.24]
AMP, PACKARD
A4
3 A2
1 8
7 58
5 6
10 3
A
A
.950[24.13]
.950[24.13]
PACKARD 630
A
AMP, 58
PACKARD
AMP,
AMP,
PACKARD
PACKARD
58
B
A
.950[24.13]
PACKARDBA630
B
AMP, PACKARD 58
1.170[29.72]
1.170[29.72]
1.170[29.72]
PACKARD 630
A
PACKARD
PACKARD
630 630
.950[24.13]
3 2 1.170[29.72]
1 8
7
B
AMP
.770[19.56]
1.170[29.72]
A
AMPAMP
AMP
1.170[29.72]
VC2
VC2
10 10
3 23 1 28 10
84 1053 6729 417VC1
845VC1
56 96 9 10 73 4 2 51 689 10 10
3 32.920[23.37]
128 1
7104 8
3 5 2 619 8VC27 4
1 38 2 1 7.920[23.37]
B B
AMP, PACKARD 58
.770[19.56]
.770[19.56]
.920[23.37]
.920[23.37]
.920[23.37]
VC2
AMP
AMP
VC2
.770[19.56]
58
7
1.250[31.75]B
AMP, PACKARD 58
MARKING
10 3DETAIL
2 1
FRONT
VIEW
FRONT VIEW
VC1
VC1
AMP, PACKARD 58
8
AMP
MARKING
7 4DETAIL
5 69
REAR
VIEW
REAR VIEW
VC1
MARKING
10 3 DETAIL
2 1FRONT
8
VC2 FRONT VIEW VC2
VIEW
AMP
MARKING
7 4 DETAIL
5 69
REAR VIEW
VC2
PACKARD 630
AMP, PACKARD 58
MARKING
DETAIL
REAR
VIEW
3 2
1 8
FRONT
VCHVIEW
AMP, PACKARD 58
MARKING
DETAIL VIEW
FRONT
4
5 6
REAR7 VIEW
VCH
VCH
MARKING DETAIL
MARKING HOUSING
DETAIL
MARKING
DETAIL
MARKINGCONNECTOR
DETAIL
MARKING
DETAIL HOUSING
CONNECTOR
HOUSING
CONNECTOR HOUSING
1.250[31.75]
1.266[32.16]
1.466[37.24]CONNECTOR HOUSING
1.266[32.16]
1.466[37.24]
CONNECTOR
HOUSING
CONNECTOR
HOUSING
CONNECTOR
HOUSING
CONNECTOR
HOUSING
CONNECTOR
VCH
VC2
FRONT VIEW
REAR VIEW
FRONT
FRONT VIEW
(For AMP terminals
only)
(For
AMP terminals only) REAR VIEW
(For
AMP VIEW
terminals
only)
VC1 VC1
VC2
VCH
CONNECTOR HOUSING
CONNECTOR
HOUSING
MARKING
DETAIL
CONNECTOR
(For AMP terminals
only)
FRONT VIEW
MARKING DETAIL
REAR VIEW
DETAIL
HOUSINGMARKING
REAR VIEW
(ForVC2
AMP terminals only)
CONNECTOR
VC2 HOUSING
CONNECTOR
HOUSING
(For
AMP terminals
only)
Contura X Boot (P/N VB1-01)
CONNECTOR HOUSING
FRONT VIEW
6
AMP, PACKARD 58
7
4
5
6
7 4
5 6
MARKING DETAIL
REAR VIEW
MARKING
DETAIL
REAR VIEW
MARKING DETAIL
REAR VIEW
MARKING DETAIL
CONNECTOR
REAR VIEW HOUSING
VCH
CONNECTOR HOUSING
Additional V-Series Ratings
VCH
CONNECTOR HOUSING
1
.4VA @ 28VDC Resistive
4
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings
1.050[26.67]
1.050[26.67]
1.050[26.67]
1.050[26.67]
51
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified
62 15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85
VB1-01
VB1-01
2 VB1-01
7VB1-01
15A
125VAC
1/2 XHP,
12(6)A 125 VAC T85
2.000[50.80]
2.000[50.80]
2.000[50.80]
CONTURA
X BOOT
CONTURA
X
BOOT
CONTURA
BOOT
1.050[26.67]
1.050[26.67]
2.000[50.80]
CONTURA
X
BOOT
2
8
10A
250VAC,
15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85
1.050[26.67]
92 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85
VB1-01
B CONTURA X BOOT
15A 24V VB1-01
2.000[50.80]
.757[19.23]
.757[19.23]
.757[19.23]
.757[19.23]
CONTURA X BOOT
2.000[50.80]
C
20A
18V
VB1-01
2.000[50.80]
CONTURA
X BOOT
D
20A 12V
E
20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
.757[19.23]
F
10A 14V, 6A, 14VT (circuit G only)
G
20A 6V
V Actuator Removal
Tool
.757[19.23]
H
20A 3V
3.99 [101.35]
.757[19.23]
3.99 [101.35]
3.99 [101.35]
3.99 [101.35]
L
15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
VRT
MVRT
REMOVAL
.4VA/20A
12V VRT
(combi-contact)
VRT
ACTUATOR
TOOL
.900 [22.86]
ACTUATOR
REMOVAL
ACTUATOR
REMOVAL
ACTUATOR
REMOVAL contacts for borderline dry circuit applications)
3.99 [101.35]
TOOL
(combination
gold/silver
(For
flush
bracket)
.900 [22.86]
.900 [22.86]
.900
[22.86]
TOOL
TOOL
(For flush
(For .4VA/15A
flush bracket)
(For
flush
bracket)
N bracket)
24V
(combi-contact)
VRT
REMOVAL
ACTUATOR
TOOL (combination gold/silver contacts for borderline dry circuit applications)
.900 [22.86]
TOP
INSERT POINTS UNDER
ACTUATOR
TOP
Contura II, III, IV &
(P/N VRT)
(For AMP terminals only)
CONNECTOR
HOUSING
MARKING
DETAIL
5
TOP
MARKING DETAIL
CONNECTOR HOUSING
FRONT VIEW
VC1
CONNECTOR HOUSING VC1
4
AMP, PACKARD 58
1.250[31.75]
3 2
1 8
PACKARD 630
PACKARD 630
VC1
VC1
VC2
1.250[31.75]
1.266[32.16]
1.466[37.24]
1.466[37.24]
MARKING DETAIL1.266[32.16]
MARKING
MARKING
DETAIL
DETAIL
MARKING DETAIL
MARKING
MARKING
DETAIL
DETAIL MARKING DETAIL MARKING
DETAIL MARKING DETAIL
MARKING
MARKING
DETAIL
DETAIL
MARKING
DETAIL MARKING
MARKING
DETAIL
DETAIL MARKING DETAIL
.950[24.13]
BMARKING DETAIL
B
FRONT
VIEW DETAIL
FRONT VIEW REAR1.466[37.24]
FRONT
VIEW
VIEW REAR
VIEW
FRONT
REARVIEW
VIEW
FRONT
VIEW DETAIL
FRONT
REAR VIEW
VIEW
REAR VIEWMARKING
FRONT
REAR
VIEW
VIEW
FRONT VIEW
REAR
FRONT
VIEW
VIEW
REAR VIEW
B DETAIL
B
1.266[32.16]
1.266[32.16]
1.466[37.24]
1.250[31.75]
MARKING
MARKING
DETAIL
MARKING
MARKING
DETAIL
PACKARD 630
B
PACKARD
630
B
AMP, PACKARD 58
6
PACKARD 630
PACKARD 630
TOP
INSERT POINTS
UNDER
INSERTAND
POINTS
INSERT POINTS UNDER
HOLD
FLUSH ON BRACKET
PUSHUNDER
ACTUATOR IN
ACTUATOR
ACTUATOR
HOLD FLUSH ON BRACKET ANDHOLD
PUSH FLUSH ON BRACKET AND HOLD
PUSH FLUSH ON BRACKET AND PUSH
IN
INTOP
IN
TOP
TOP
TOP
INSERT POINTS UNDER
ACTUATOR
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
TOP
(For flush bracket)
3.99 [101.35]
3.99 [101.35]
NOTES
Consult factory to determine availability for individual circuits and their HP rating.
VRT
VRT
1.
Not avaiable
with Contura
7 or 14 rocker styles.
ACTUATOR
REMOVAL
INSERT POINTS UNDER
ACTUATOR
INSERT POINTS
UNDER
2.
Ratings
6 - 9 REMOVAL
are UL,
CSA & VDE certified, require terminations A or B for double
.900
[22.86]
ACTUATOR
TOOL
ACTUATOR
TOOL
HOLD FLUSH ON BRACKET AND PUSH.900 [22.86]
HOLD FLUSH
INON BRACKET AND PUSH
(For
flush
bracket)
pole(For
circuits,
are not available with illumination circuits 4, 8, D, J, N, & T or with
IN
flush &
bracket)
TOP
TOP
wire lead or solder lug terminations.
Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available
with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8.
Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp
code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only.
TOP
TOP
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
22 | V-Series Contura Sealed Rocker Switch Accessories
Contura Mounting Panels
Dimensional Specifications: in. [mm]
Contura Hole Plug
Dimensional Specifications: in. [mm]
1.450 [36.83]
.830 [21.08]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
VHP
CONTURA II,III HOLE PLUG
1.240 [31.50]
1.820 [46.23]
.430 [10.92]
VHP
CONTURA II,III HOLE PLUG
VH1
STANDARD HOLE PLUG
(No wing serrations)
(With VC1 connector attached)
2.000 [50.80]
VH2
STANDARD HOLE PLUG
(With wing serrations)
1.067 [27.10]
(TYP. FOR VH3 & VH4)
1.928 [48.97]
VH3
CONTURA IV HOLE PLUG
(No wing serrations)
VH4
CONTURA IV HOLE PLUG
(With wing serrations)
DETAIL VIEW
VH1,VH3 & VH5
HOLE PLUGS
(No wing serrations
for ease of removal)
1.020 [25.91]
(TYP. FOR VH5 & VH6)
VH5
CONTURA V HOLE PLUG
(No wing serrations)
VH6
CONTURA V HOLE PLUG
(With wing serrations)
DETAIL VIEW
VH2,VH4 & VH6
HOLE PLUGS
(With wing serrations)
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Notes | 23
* Intentionally left blank
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
East Region Sales Office, CT • [email protected]
Midwest Region Sales Office, IL • [email protected]
West Region Sales Office, CA • [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China • [email protected]
Shanghai, China • [email protected]
Pune, India • [email protected]
Kaohsiung, Taiwan • [email protected]
Yokohama, Japan • [email protected]
Europe/Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: [email protected]
GmbH, Germany • [email protected]
SAS, France • [email protected]
REV_SW_V_06_2014

Similar documents

V-Series - Carling Technologies

V-Series - Carling Technologies V-Series Contura Switches V-Series switches offer countless unique options including choices for ratings, colors, illuminations and symbols. These switches feature removable actuators in a choice o...

More information