Submersible Borehole Pumps
Transcription
Submersible Borehole Pumps
Type series booklet 3400.51/2--10 60 Hz Submersible Borehole Pumps Applications --------- Submersible Borehole Pumps Drinking and service water supply Irrigation and spray irrigation Lowering and maintaining ground water levels Pressure boosting Fountains Mining, offshore, tank farms Building services systems VDS sprinkler systems S 100D, UPA 100C, UPA 150C, UPA 200, UPA 200B, UPA 250C, UPA 300, UPA 350, BSX - BSF, UPZ Operating Data Capacity . . . . . . . . . . . . . . . . . . Q up to 1080 m3/h (300 l/s or up to 5000 US GPM) Head . . . . . . . . . . . . . . . . . . . . . H up to 460 m Temperature of fluid handled . . t up to +50 oC Speed . . . . . . . . . . . . . . . . . . . . n ≈ 3500 rpm Supply voltage . . . . . . . . . . . . . U up to 10,000 V Design Single-- or multistage centrifugal pumps in pump shroud or in ring--section design. Radial or mixed flow hydraulic systems; reduced impeller diameters also available in some cases. The stage casings of radial pumps are connected by metal straps, those of mixed flow pumps by stud bolts. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Available with threaded or flanged end on option. Particularly suitable for vertical installation in narrow deep wells. Pump Designation (Example) UPA 200 B -- 80 / 5 b Type series Minimum well diameter (mm) (for ex.: 200 mm = 8 inches) Design status Capacity (Qopt at 50Hz) m3/h (4 up to 10 inches) 1) l/s (12 inches and above) Number of stages Reduced impeller diameters 1) Available automation products: UPA 200 -11 + 14: Q in l/s. Motor Designation (Example) UMA 250 D 110 / 2 1 Type series Well diameter (mm) (for ex. 250 mm = 10 inches) Design status Rated power PN for 50 Hz (kW) Number of poles Winding insulation • Hyamaster (UPA 200 and UPA 300) Complete Range The complete submersible borehole pump range comprises pump models for capacity up to Q = 2500 m3/h (695 l/s) and heads up to H = 1500 m. The submersible motor range covers sizes for power ratings up to P = 3500 kW (4700 hp) and voltages up to U = 10,000 V for 50 and 60 Hz. In addition, a special range is available which features submersible motors with a higher number of poles. Certification Quality management certified to ISO 9001 60 Hz Contents Submersible Borehole Pumps Page The 60 Hz Submersible Borehole Pump Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation with Soft Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation with Frequency Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Typical Installation Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Submersible Borehole Pump Selection for Deep Wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Request for Quotation (Form) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Head Losses in the Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pump Sets 4 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Pump Sets 6 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Pump Sets 8 Inches / 10 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Pump Sets 12 Inches / 14 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Pump Sets 16 Inches and Above . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Typical Tenders: 4 to 14 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Submersible Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Flow Velocity ”v” Past the Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 2 60 Hz What can you expect from the Booklet “Submersible Borehole Pumps”? The information provided can help you make a -- quick -- first rough selection -- on your own to find a suitable KSB submersible borehole pump for your application. We have kept the volume of the catalogue down to what we think is the absolute minimum. For the 4 to 14 inch range, you will find the following information on the pump selected: -- pump series, size and number of stages, -- motor series, size, power, amperage and allowable temperature, -- starting method, supply voltage and type of installation, -- material variants and -- major dimensions and weights. You may also complete, to the extent possible, the request for quotation on page 9. You will then receive as soon as possible a detailed quotation and, if required, additional literature on KSB submersible borehole pumps from the nearest KSB sales branch. Submersible Borehole Pumps General Information on fields of application, available models, type of installation, direction of rotation, coating, connection to power supply and speed control is provided in the detailed sections for the relevant type series. Pump Efficiency The characteristic curves for UPA 200/200B and larger pumps show pump efficiency for the maximum and optimum (reduced) impeller diameter (for ex. ”c”). The efficiency of pumps with a low number of stages or considerably reduced impeller diameter (for ex. ”d”, “e”) is lower than the value shown; it is given in the individual characteristic curves specifically prepared for the quotation. Dry Running Protection For use in wells with marked water level fluctuations or temporary low yield we strongly recommend installing dry running protection equipment (”Accessories”). Application Temperatures Benefits at a Glance + + + + + + + + + Full range of products High-tech equipment Optimum material selection Maximum efficiency Functional reliability Long service life No maintenance ”Clean” technology Customer focus The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = +30 oC. An indispensable requirement for this is a flow velocity of v = 0.2 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = +50 oC and for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.). The details below provide data of adequate accuracy for the allowable temperature as a function of the type of installation, motor size and flow velocity v past the motor: Vertical installation: -- DN 100 / DN 150: tallow = tmax1) irrespective of flow past the motor. -- UMA 150D/200D: v = 0 m/s . . . . . . tallow ≈ tmax1) -- 5 oC, v ≥ 0.2 m/s . . . . tallow = tmax1), v ≥ 0.5 m/s . . . . tallow ≈ tmax1) + 5 oC. -- UMA 250D: v = 0 m/s . . . . . . Please consult manufacturer, v ≥ 0.2 m/s . . . . tallow = tmax1), v ≥ 0.5 m/s . . . . tallow ≈ tmax1), + 5 oC. 1) Values taken from tables on pages 15, 16 etc., 27, 28 etc.. Horizontal installation: The principle is the same as for vertical installation. Exception: Pumps with UMA 250D motors. These units must always be equipped with a flow inducer sleeve. The flow inducer sleeve is not required, if the given pump is equipped with a motor having a 10 % higher power rating. For all pump sets: For a flow velocity of v ≥ 0.5 m/s and horizontal installation, check back with the manufacturer. 3 60 Hz Submersible Borehole Pumps The 60 Hz Submersible Borehole Pump Range " UPZ 1) BSX, BSF 1) (≥16 inches) " UPA 100C (4 inches) " UPV 200 (8 inches) " UPA 200 (8/10 inches) " S 100D (4 inches) " UPA 150C (6 inches) " UPA 200B (8/10 inches) " UPA 300, 350 (12/14 inches) " UPA 250C (8/10 inches) 4 60 Hz Submersible Borehole Pumps Operation of KSB Submersible Borehole Pumps with Soft Starters Soft starters electronically reduce the incoming line voltage and, hence, the initial starting torque and starting current of electric motors. During run--up they gently ramp up the applied voltage to the motor. In the case of submersible motors, the extremely slim design and consequential small moments of inertia result in special characteristics, which differ strongly from normal asynchronous motors. Effects on submersible borehole pumps -- Starting current ⇒ approx. 40% to 65% of IA required for d.o.l. starting. -- Run-up time tH increased to approx. 1s to 3s compared with approx. 0.2s to 0.5s for direct-starting. -- Starting torque MA roughly 1/4 of the direct-starting torque. -- No current or torque peaks (IA, MA), as in star-delta switching arrangement. -- Hydraulic pressure surges (waterhammer) upon starting and stopping of the pump can be reduced, but not fully eliminated. Therefore, soft starters are not suitable for solving water hammer problems. This would require the use of hydraulic control equipment or a frequency inverter. To prevent effects due to power failure, additional measures are required. Note Conspicuous noise or vibrations during run-up could well be an indication of incorrect settings on the soft starter. This might be due to exceeded ramp--up periods, incorrect operating mode (setting), activated special functions, etc. Soft starter settings Parameter / Function Setting Comments Minimum starting voltage 40% of the motor’s rated voltage Ramp time / acceleration (run-up) time < 4s Ramp time is not identical with the motor’s actual running-up time Current limitation IA / IN preset to approx. 3.5 Should only be altered with allowance for tH < 4s Deceleration (run-down) time / stop ramp Deceleration time tA < 4s Better without a ramp. Special functions, e.g.: -- special “pump function” -- kick-start / boost function -- speed adjustment -- Current controller -- cos ϕ / economy function -- delayed starting OFF Do not use, as they tend to be troublesome, particularly in submersible borehole applications. Voltage [%] During operation the soft starter must be bridged (bypass). This helps to avoid losses at the machine and motor to secure proper permanent operation. 120 100 80 Run-up Operation Run-down 60 40 20 0 4s Time [s] 4s 5 60 Hz Submersible Borehole Pumps Pump Operation with Frequency Inverter In principle, the motors of submersible borehole pumps can also be run on a frequency inverter. As submersible motors differ from conventional standardized motors in terms of bearings, moment of inertia, insulation, temperature increase, loss distribution and heat distribution, the following parameters must be observed: -- Maximum allowable acceleration time (start ramp) -- Maximum allowable deceleration time (stop ramp) -- Minimum frequency -- Maximum operating frequency -- Maximum permissible voltage increase velocity and peak voltages -- Control principle of frequency inverter Maximum Allowable Acceleration Time (Start Ramp) and Deceleration Time (Stop Ramp) The plain bearings of the submersible motor operation below the minimum frequency fmin do not tolerate (operation in mixed lubrication range). For this reason, the acceleration period from standstill to minimum frequency fmin should not exceed 2s. The same applies to the deceleration period. Minimum Frequency Minimum frequency fmin (Hz) Motor size DN 100 DN 150 Vertical installation 30 Horizontal installation 30 ---- UMA 150D UMA 200D UMA 250D 20 30 30 35 UMA 300D /2 UMA 300D /4 6 Maximum Operating Frequency Frequency inverter operation above the nominal frequency (50Hz / 60Hz) of the pump unit must be avoided so as, to prevent motor overload. Maximum Permissible Voltage Increase Velocity and Peak Voltages Excessive voltage increase velocities and excessive peak voltages will reduce the service life of the winding insulation. For this reason, the following limits must be adhered to: -- Maximum voltage increase velocity: du/dt ≤ 500 V/µs -- Maximum peak voltages to earth: Low-voltage motors ≤ 1 kV: J1 insulation ≤ 600 V J2 insulation ≤ 800 V Note: Compliance with these limits can usually be assured by means of a sine filter or du/dt filter. Control Principle of Frequency Inverter The control principle of the frequency inverter must correspond to linear U/f curve control. If other control principles are employed, such as field-oriented inverters, inverters with DTC or NOF, the manufacturer of the frequency inverter must ensure that the special requirements of submersible motors (very small moment of inertia, electrical data) are taken into account. 60 Hz Submersible Borehole Pumps Typical Installation Positions a) Vertical Installation (deep well, pump sump, etc.) CAUTION: The construction of the well head must meet the relevant regulations of the competent authorities! The unit must never be installed with its suction strainer exactly at the level of the well screen / filter! Before installing the unit in narrow deep wells we recommend to check narrow boreholes for dimensional accuracy over their entire length, e.g. by inserting a pipe of the length and biggest outside diameter of the pump unit. Sharp bends or bottlenecks can make installation difficult or even impossible. The unit is supported on the well head by supporting clamps (low-weight units and low submergence) or a supporting flange. The construction of the well head must meet the relevant regulations of the competent authority. 5 8 4 7 6 Ht Hh 3 He B B X 2 TF 1 1 2 3 4 5 6 7 8 9 Submersible borehole pump Riser pipe Cable tie Supporting flange / Well head Pressure gauge Shut-off valve Power supply cable Control box Well screen / filter D TB TF He Hh Ht Fig. 1 = = = = = = TB 9 Cooling / Suction shroud Fig. 2 b) Installation in a pump sump 3400:50 Horizontal Installation (in reservoirs, mine shafts, etc.) CAUTION: The instructions given in ”a) Vertical installation” shall also apply by analogy to horizontal installation, when the pump unit is fitted on mounts (pedestals / supporting frame) supplied by us. If the pump and motor are supplied ready mounted on a supporting frame, on-site alignment of pump and motor will not be necessary. If this is not the case, the relevant installation / assembly drawing must be ordered, giving the following details: -- installation height (floor clearance), -- spacing of supports, -- submergence X The ground / foundation must be level and of sufficient load-bearing capacity to accept the weight of the unit with supports. Air intake from an inlet arranged above the water level is not permitted. D 3410:70/4 Inside well diameter Well depth Well screen / filter depth Installation depth Static water level Dynamic water level (Pumping water level) Vertical installation (in deep well, pump sump, etc.) The suspension arrangement of the pump unit must be designed and dimensioned so that all static and dynamic forces can be absorbed and that the riser pipe cannot slip downwards. The supporting clamps or flanges must be fastened at the well head so that they cannot shift of lift off the well head. The unit must never be installed with its suction strainer exactly at the level of the well screen / filter! Excessive flow in the area of the well screen / filter entails the risk of large amounts of entrained sand clogging the well screen / filter and causing excessive wear in the pump. Pump units installed in a pump sump must generally be equipped with a cooling or suction shroud (fig. 2). X 3410:71/2 Fig. 3 Horizontal installation (in tanks, mine shafts etc.) 1 2 3 4 5 Submersible borehole pump Water storage tanks (UMA 300D and 14D motors only) Pedestal Expansion joint Check valve (only if pump unit does not have its own check valve) 6 Dismantling joint 7 Shut-off valve 8 Intake 7 60 Hz Submersible Borehole Pumps Selection for Deep Wells Pump Selection The following data are required for a first rough selection of a submersible borehole pump: -- Capacity Q in m3/h (l/s) -- Pressure at well head HA in m -- Well diameter D in inches or mm -- Temperature of fluid handled tA in °C -- Pump head HP in m While Q, HA, D and tA are usually specified by the customer, the head HP to be developed by the pump needs to be calculated. There are two typical applications to be considered (see the drawing on the right): 1. Pumping into an open overhead tank HP = HA + Ht + Hv + HS [m] with ... HA = Required pressure at well head Ht = Lowest water level (dynamic water level) Hv = Head losses in the check valve (see characteristic curves for different stage numbers for UPA 150S and above). HS = Head losses in riser pipe up to well head (see page 10). He = Installation depth 2. Pumping into a closed tank Hp = HA + Ht + Hv + HS + pü [m] with ... pü = Gauge pressure (also air cushion) in a tank Example Given ... " QA = 120 m3/h, " HA = 100 m, " tA = + 15 °C, " 50 Hz, " 400 V, " d.o.l. starting, " well diameter D = 300 mm (12 inches), " Ht = 33 m, " He = 60 m Found ... 1. step: pump type UPA 200B/250C . (for QA taken from selection chart on page 4) 2. step: pump size UPA 250C - 120 . (for QA taken from selection chart on page 50) 3. step: pump set UPA 250C-120/3f + UMA 200D 65/21 . (for Hp = HA + Ht + HV + HS = 100 + 33 + 0.5 + 1.5 = 135 m . with HV taken from characteristic curves for different stage . numbers on page 61). . Pump efficiency: ηP = 81 % (without check valve) 3300:54/3 Figure: Deep well with submersible borehole pump and overhead tank or closed tank at a pressure above atmospheric pressure of pÜ. 8 60 Hz Request for Quotation We should like to test the efficiency and quality of your computer-aided quotation process. Please let us have a quotation based on the following data. (Fill in the required data and / or underline the relevant information, as far as available.) 8 1. Water quality Temperature . . . . . . . . . . . . . . . . . . . . . °C Sand content . . . . . . . . . . . . . . . . . . g/m3 7 6 Nominal diameter . . . . . . . . . . . . . . . mm 6. Installation depth He = . . . . . . . . . . . . m Well depth (distance from ground level to well base): Caution: Do not install the submersible borehole pump at the level of the well screen / filter! Inside diameter at submersible pump installation depth: D = . . . . . . . . . . . . . . mm ( . . . . inches) 7. Power supply Well screen / filter: Single- / three-phase alternating current. Mains voltage at well: U= ............................. V -- Installation depth TF = . . . . . . . . . . . m Frequency f = . . . . . . . . . . . . . . . . . . Hz -- Length LF = . . . . . . . . . . . . . . . . . . . m If voltage drops cannot be precluded: 4. Capacity Q = . . . . . . . . . . . . . m3/h ( . . . . . . . l/s) H= ............................ m 3300:54/3 Overall length . . . . . . . . . . . . . . . . . . . . m 3. Deep well (including all friction losses) Well screen / filter Well casing Submersible borehole pump Riser Well head housing Well head Power supply cable Overhead tank piping outside well head housing: Ground level to check valve / to connection branch: 5. Total head 1 2 3 4 5 6 7 8 c) . . . . . . . . . . . . bar Discharge into a pressure vessel TB = . . . . . . . . . . . . . . . . . . . . . . . . . . . . m 1 pÜ = Inside diameter reduced by incrustation to: D = . . . . . . . . . . . . . . . . . . . . . . . . mm 5 F Cut-out pressure in the pressure vessel: 2. Type of system Discharge into an overhead tank 2 H = . . . . . . . . . . . . . m ( . . . . . . . . bar) Number of bends, valves and fittings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pcs Free discharge above ground 3 Discharge head required at the end of the piping: Please attach water analysis, if available. Well / Mine shaft / Tank 4 Submersible Borehole Pumps If H is not known, please provide the following data: a) Water level in well, measured from ground level: -- Static water level: Hh = . . . . . . . . . . m -- Dynamic water level: Ht = . . . . . . . . m (at capacity Q = . . . . . . . . . . . . . . m3/h) b) Head above ground: Geodetic altitude up to the highest point of the pipeline or up to the highest water level in the overhead tank: Minimum voltage ... Umin = . . . . . . . . . . . V 8. Control box Manual start-up / remote control / automatic start-up by way of float switch, pressure switch or dry running protection equipment. Other types of switchgear: . . . . . . . . . . . ................................... 9. Starting method D.o.l. (without / with autotransformer or soft starter) or star-delta starting. Hd = . . . . . . . . . . . . . . . . . . . . . . . . . . . m 9 60 Hz Submersible Borehole Pumps Head Losses in the Piping HV ft/100 ft HV m/100 m 3300:103/3-2 The friction losses given in the above chart roughly apply to new cast iron pipes. For new rolled steel or plastic pipes, multiply the values by approx. 0.8. For old, slightly rusty cast iron pipes, multiply by approx. 1.25. In pipes with incrustations, friction losses may rise to 1.7 times the value given in the chart for the 10 diameter reduced by incrustations. For pipes subject to considerable incrustation, the friction losses can only be determined experimentally. Example: Q = 140 m3/h, new DN 150 cast iron pipe. HV = 3.25 m per 100 m of pipe, v = 2.2 m/sec. 60 Hz Applications --------- S 100D Submersible Borehole Pumps Domestic and general water supply Irrigation and spray irrigation Lowering groundwater levels Fountains Pressure boosting Air-conditioning systems Fire protection Cooling water cycles for Well Diameters of 100 mm (4 inches) and Above Operating Data Capacity . . . . . . . . . . . . . . . . . . . Q up to 16 m3/h (4 l/s or up to 60 US GPM) Head . . . . . . . . . . . . . . . . . . . . . . H up to 300 m Temperature of fluid handled . t up to +30 °C in continuous operation Power . . . . . . . . . . . . . . . . . . . . . Pn up to 6.4 kW (8.7 hp) Design Pump: Stainless steel and plastic multistage centrifugal pump. -- Additional bearing depending on the number of stages -- Pump sizes D1 and D2 with anti-blockage feature. This consists of a hexagonal polyurethane disc mounted to the back of the diffuser. A PE-HD ring fitted to the impeller front side sits close to the disc. The impeller hub is protected by a polyurethane ring.This design improves the starting torque of low-capacity pumps and has the effect that solid particles such as sand are propelled outside instead of clogging the pump. Motor: Submersible canned motor (Franklin), NEMA standard, 60 Hz -- For three--phase current -- With motor lead -- Connection to power supply mains by means of cable connector (accessories) -- D.o.l., start-up frequency up to 20 / h -- Type of enclosure IP 68 -- Thermal class B Designation S 100 D -- 4 / 6 Type series Well diameter (mm) Design status Capacity (m3/h) Number of stages Certification Quality management certified to ISO 9001 Product Features ----------- Pumps sizes D1 and D2 with anti-blockage feature Rust-proof Suitable for installation in narrow deep wells High efficiency Hermetically sealed motor Motor designed for maximum pump output Low noise level For vertical, angled or horizontal installation Check valve with anti-blockage valve disc Easy dismantling of check valve 11 60 Hz S 100D Selection Chart (Ranges on Offer) n ¶ 3450 rpm S 100D 2 S 100D 1 S 100D 4 S 100D 7 12 S 100D 12 60 Hz Materials Drive Component Execution C1 Pump ... Outer pump casing / Suction casing / Valve housing CrNi steel (1.4301) Stage casing CrNi steel (1.4301) Stage casing (diffuser) / Impeller S 100D glass fibre reinforced Noryl (PPO) Shaft Cr steel (1.4021) Bearing bush Nitril NBR 80 Screws, bolts and nuts CrNiMo steel (A4--70) Motor ... Type . . . . . . . . . . . . . . . . . . . . . . . canned motor in squirrelcage design, 2 poles Connection . . . . . . . . . . . . . . . . . NEMA standard Type of enclosure . . . . . . . . . . . IP 68 Frequency . . . . . . . . . . . . . . . . . 60 Hz Type of current . . . . . . . . . . . . . . three-phase (3 µ) Rated voltage U . . . . . . . . . . . . . 460 V Rated power PN . . . . . . . . . . . . . . . . up to 5.5 kW (7.5 hp) Voltage fluctuations . . . . . . . . . . up to ± 5 % acc. to VDE Frequency of starts . . . . . . . . . . up to 20 / h Min. delay before restarting . . . . 3 min Shaft CrNi steel (1.4305) Bearing carrier CrNi steel (1.4301) Connection to Power Supply Stator case CrNi steel (1.4301) All DN 100 motors are factory-equipped as follows: Bearings / Lubrication Plain bearings, lubricated by the fluid pumped or by the motor fill liquid. Depending on the number of stages, an additional intermediate bearing is provided in the pump. The axial thrust is balanced by a thrust bearing in the motor. The hydraulic thrust is balanced by the pump’s counter thrust bearing. Direction of Rotation of the Pump Clockwise rotation (viewed at the drive shaft end). Pump End (Discharge Nozzle) S 100D - 1, 2, 4 + 7: Internal thread G 11/4” (DN 32). S 100D - 12: Internal thread G 2’’ (DN 50). Installation Vertical and, depending on the number of stages, inclined as well as horizontal installation (see tables on page 15 to 19) 1 x 1.5 m flat cable, quality 4 x 1.5 mm2 (3 phases + 1 earth conductor). Exception: DN 100 motors with a rating of 5.5 kW, 3~, are equipped as follows: 1 x 2.5 m cable, quality 4 x 1.5 mm2. Connection of extension cable (any length) by means of a cable connector: Connected at the factory by means of a standard cable connector (non-separable, shrink tube) -- Ident No. 40 980 708 For cable quality 4 x 1.5 mm2 or 4 x 2.5 mm2 -- Ident No. 39 020 536 For cable quality 4 x 4 mm2 Connected at the factory with Franklin cable connector (separable, sealing compound) -- Ident No. 90 049 385 For cable quality 4 x 1.5 mm2 up to 4 x 2.5 mm2 Starting Mode Only direct on line. Temperatures The S 100D submersible borehole pump is designed for use in water with temperatures of up to t = + 30 oC. 13 60 Hz S 100D Design Features (Pump sizes D1 -- D2) Stainless steel valve housing Non-return valve with double-guided valve disc -- No jamming or tilting. -- If not required, the non-return valve may be removed. Diffusers with smooth surfaces -- Made of glass fibre reinforced Noryl. Pump bearing with grooves -- Maintenance-free and highly wear-resistant. -- For smooth long-term operation. Stainless steel cable guard -- Easy assembly and dismantling. -- Protects the power supply cable against damage. High-performance impellers -- Made of glass fibre reinforced Noryl, highly abrasion- and corrosion-resistant. -- With integrated keys for easy assembly. State-of-the-art sintered metal coupling -- For optimum power transmission. Stainless steel stage casing without return vanes -- High pressure resistance. -- Easy assembly and dismantling. Anti-blockage feature with self-lubricating reinforcing rings with good anti-seizure properties and high abrasion resistance. -- Ensures smooth operation in water with a low sand content. -- Suitable for the low starting torque of pump sizes D1 and D2 for small capacities. Stainless steel suction casing Franklin submersible motor -- Designed for max. pump power to protect unit from overloads. -- Easy-to-fit plug-and-socket connection of power supply cable. 14 60 Hz S 100D S 100D -- 1 for well diameters of 100 mm (4 inches) and above Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . up + 30 oC -- Current / Operating voltage . . . . . . 3 µ/460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . direct Rated power Rated power (motor) (motor) Pump unit S 100D PN kW PN hp IN A 1 1 1 1 1 1 1 1 1 0.59 0.83 0.83 1.0 1.0 1.4 1.8 1.8 1.8 0.80 1.13 1.13 1.36 1.36 1.90 2.45 2.45 2.45 1.5 2.1 2.1 2.4 2.4 3.1 4.1 4.1 4.1 1) / 7 / 9 / 12 / 14 / 16 / 20 / 25 / 30 / 35 Current intensity for 3µ 460 V Tolerances to ISO 9906 Class 2 Annex A Installation 1) v+h v+h v+h v+h v+h v+h v v v v = vertical, h = inclined / horizontal. Note: Use a cooling shroud for horizontal installation. Capacity The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers / Horizontal Installation Pump unit S 100D LA ¶ mm mA ¶ kg 1/ 7 1/ 9 1 / 12 1 / 14 1 / 16 1 / 20 1 / 25 1 / 30 1 / 35 546 619 686 760 805 923 1064 1176 1366 10.7 11.8 12.2 13.6 13.8 15.7 17.5 18.0 20.0 3 µ / 460 V Ident. No. ¶ 39 022 613 39 022 614 39 020 615 39 022 616 39 022 617 39 022 618 39 022 619 39 022 620 39 300 025 A mm 410 450 530 590 630 720 ----- ----- C G 11/4” For information on cooling shroud refer to page 20. 15 60 Hz S 100D S 100D -- 2 for well diameters of 100 mm (4 inches) and above Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . up + 30 oC -- Current / Operating voltage . . . . . . 3 µ/460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . direct Current Installation 1) intensity for 3µ 460 V Rated power Rated power (motor) (motor) Pump unit S 100D PN kW PN hp IN A 2 2 2 2 2 2 2 2 2 1.00 1.40 1.80 2.50 2.50 2.50 3.40 3.40 4.20 1.36 1.90 2.45 3.40 3.40 3.40 4.62 4.62 5.71 3.4 4.3 5.6 8.6 8.6 8.6 10.6 10.6 15.5 1) / 7 / 11 / 15 / 18 / 20 / 22 / 27 / 30 / 33 Tolerances to ISO 9906 Class 2 Annex A v+h v+h v+h v+h v+h v+h v v v v = vertical and h = inclined / horizontal Note: Use a cooling shroud for horizontal installation. Capacity The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers / Horizontal Installation Pump unit S 100D 2/ 7 2 /11 2 /15 2 /18 2 /20 2 /22 2 /27 2 /30 2 /33 LA ¶ mm 594 721 839 935 980 1048 1205 1272 1506 mA ¶ kg 12.6 14.4 16.0 17.7 17.8 18.1 21.5 21.9 28.3 For information on cooling shroud refer to page 20. 16 3 µ / 460 V Ident-No. A C ¶ mm 39 022 621 39 022 622 39 022 623 39 022 624 39 022 625 39 022 626 39 022 627 39 022 628 39 022 629 410 530 630 750 750 750 ----- ----- G 11/4” 60 Hz S 100D S 100D -- 4 for well diameters of 100 mm (4 inches) and above Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . up + 30 oC -- Current / Operating voltage . . . . . . 3 µ/460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . direct Rated power (motor) (motor) Pump unit S 100D PN kW PN hp IN A 4 4 4 4 4 4 4 1.00 1.80 2.50 2.50 4.20 4.20 4.20 1.36 2.45 3.40 3.40 5.71 5.71 5.71 2.4 4.1 5.6 5.6 8.7 8.7 8.7 1) 21 Tolerances to ISO 9906 Class 2 Annex A 16 Current Installation 1) intensity for 3µ 460 V Rated power / 3 / 6 / 8 / 11 / 16 / 21 / 24 24 11 8 v+h v+h v+h v+h v+h v+h v 6 3 v = vertical, h = inclined / horizontal. Note: Use a cooling shroud for horizontal installation. Capacity The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers / Horizontal Installation Pump unit S 100D LA ¶ mm mA ¶ kg 4/ 3 4/ 6 4/ 8 4 /11 4 /16 4 /21 4 /24 556 663 768 845 1160 1287 1364 12.8 16.0 17.7 18.2 28.4 29.5 30.0 3 µ / 460 V Ident. No. ¶ 39 022 630 39 022 631 39 022 632 39 022 633 39 022 634 39 022 635 39 022 636 A mm 410 450 530 630 875 990 -------- C G 11/4” For information on cooling shroud refer to page 20. 17 60 Hz S 100D S 100D -- 7 for well diameters of 100 mm (4 inches) and above Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . up + 30 oC -- Current / Operating voltage . . . . . . 3 µ/460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . direct Current Installation 1) intensity for 3µ 460 V Rated power Rated power (motor) (motor) Pump unit S 100D PN kW PN hp IN A 7 7 7 7 7 7 1.80 2.50 3.40 4.20 4.20 6.40 2.45 3.40 4.62 5.71 5.71 8.70 4.1 5.6 7.4 8.7 8.7 13.1 1) / 4 / 6 / 8 / 11 / 13 / 18 18 Tolerances to ISO 9906 Class 2 Annex A 13 11 8 v+h v+h v+h v+h v+h v 6 4 v = vertical, h = inclined / horizontal. Note: Use a cooling shroud for horizontal installation. Capacity The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers / Horizontal Installation Pump unit S 100D 7/ 4 7/ 6 7/ 8 7 /11 7 /13 7 /18 LA ¶ mm 671 768 903 1127 1195 1518 mA ¶ kg 15.8 17.7 21.1 27.8 28.3 35.9 For information on cooling shroud refer to page 20. 18 3 µ / 460 V Ident. No. A C ¶ mm 39 022 637 39 022 638 39 022 639 39 022 640 39 022 641 39 022 642 450 530 650 875 960 -- -- G 11/4” 60 Hz S 100D S 100D -- 12 for well diameters of 100 mm (4 inches) and above Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . up + 30 oC -- Current / Operating voltage . . . . . . 3 µ/460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . direct RatedRatedCurrent Installation 1) power power intensity for (motor) (motor) 3µ 460 V Pump unit S 100D PN kW PN hp IN A 12 12 12 12 1.80 3.40 4.20 6.40 2.45 4.62 5.71 8.70 4.1 7.4 8.7 13.1 1) / 4 / 6 / 10 / 13 Tolerances to ISO 9906 Class 2 Annex A v+h v+h v v v = vertical, h = inclined / horizontal. Note: Use a cooling shroud for horizontal installation. Capacity The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers / Horizontal Installation Pump unit S 100D 12 / 4 12 / 6 12 /10 12 /13 LA ¶ mm 835 1039 1378 1694 mA ¶ kg 15.9 21.3 28.3 37.0 3 µ / 460 V Ident. No. A C ¶ mm 39 022 643 39 022 644 39 022 645 39 022 646 630 750 ----- -- G 2” For information on cooling shroud refer to page 20. 19 60 Hz S 100D Permissible Cable Lengths ∆U up to 3 %, direct starting and t up to + 30 oC Current / Voltage 3µ/ 460 V Motor rating Motor rating Cable lengths for cable cross-section in ... mm2 kW hp 1.5 2.5 4.0 6.0 1.0 1.4 1.8 3.2 3.4 4.2 6.4 1.36 1.90 2.45 4.35 4.62 5.71 8.70 352 m 262 m 203 m 154 m 118 m 97 m 62 m 587 m 437 m 339 m 258 m 197 m 161 m 104 m ---700 m 542 m 413 m 316 m 259 m 167 m ---------619 m 474 m 388 m 251 m Technical Data - Cooling Shroud Pump unit S 100D Installation 1) 1/7 to 1/16 2/7 4/3 Dimensions (dia. x length) and motor type (kW) Cooling Shroud Ident. No. v+h v+h v+h Ø115 (130) x 400 up to 1.0 kW (3~) Weight 1.5 kg 90 065 490 1/20 to 1/30 2/11 to 2/15 4/6 7/4 12/4 v v+h v+h v+h v+h Ø115 (130) x 500 up to 1.8 kW (3~) Weight 1.7 kg 90 065 491 2/18 to 2/22 2/27 to 2/30 4/8 to 4/11 7/6 to 7/8 12/6 v+h v v+h v+h v+h Ø115 (130) x 625 up to 3.4 kW (3~) Weight 2.0 kg 90 065 492 2/33 4/16 to 4/21 4/24 7/11 to 7/13 7/18 12/10 to 12/13 v v+h v v+h v v Ø115 (130) x 800 up to 6.4 kW (3~) Weight 2.5 kg 90 065 493 1) 20 v = vertical, h = inclined / horizontal Strainer Ident. No. Support feet Ident. No. 90 065 494 90 065 495 Ø115x117 Weight 0.3 kg Set = 2 pc. Weight 0.6 kg 60 Hz Applications --------- UPA 100C Submersible Borehole Pumps Domestic and general water supply Irrigation and spray irrigation Groundwater lowering Fountains Pressure boosting Air-conditioning systems Fire protection Cooling water cycles of Stainless Steel for Well Diameters of 100 mm (4 inches) and Above Operating Data Capacity . . . . . . . . . . . . . . . . . . . Q up to 18 m3/h (5 l/s or up to 80 US GPM) Head . . . . . . . . . . . . . . . . . . . . . . H up to 450 m Temperature of fluid handled . . t up to +30 °C Motor ratings . . . . . . . . . . . . . . . PN up to 7.5 kW (10 hp) Maximum permissible amount of suspended sand: . . 50 g/m3 Design Multistage centrifugal pump with components made of stainless steel and additional bearing for each stage. Submersible canned motor: Franklin Electric pre-filled motors, corrosion free, NEMA shaft end, 60 Hz -- three-phase motor type Super Stainless -- with separate lead -- direct start, max starts : 20 / h -- Type of enclosure: IP 68 -- Insulation: Class B Designation Type series Minimum well diameter (mm) Design status Capacity Qopt (US GPM) Number of stages Certification UPA 100 C 10 -- 6 Quality management certified to ISO 9001 Product Features ----------- Very sturdy design All components made of stainless steel Suitable for installation in narrow deep wells High efficiency Totally enclosed motor Motor designed for maximum pump output Low noise level For vertical or horizontal installation Non-return valve protected against blocking Pre-filled motor without risk of contamination of the pumped water 21 60 Hz Selection Chart (Ranges on UPA 100C n ¶ 3500 rpm Offer) UPA 100C 16 UPA 100C 10 UPA 100C 22 UPA 100C 35 UPA 100C 60 UPA 100C 22 UPA 100C 16 UPA 100C 35 UPA 100C 10 UPA 100C 60 Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this range. The operating ranges ∆QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages. 22 60 Hz Materials UPA 100C Drive Components Execution C1 Pump ... Type . . . . . . . . . . . . . . . . . . . submersible canned motor Connection . . . . . . . . . . . . . NEMA standard Type of enclosure . . . . . . . . IP 68 Diffuser, upper diffuser, lower diffuser, Impeller, Pump shaft with NEMA coupling, Suction casing, suction filter, Discharge casing, Spacer sleeve, Hook stainless steel AISI 304 Seal ring NBR + AISI 316 Upper bearing bush NBR + AISI 316 Starting Mode Intermediate bearing bush NBR Direct on line. Valve face NBR + AISI 316 Frequency . . . . . . . . . . . . . . 60 Hz Type of current . . . . . . . . . . three-phase Rated voltage U . . . . . . . . . 3~ 460 V Rated power PN . . . . . . . . . up to 7.5 kW (10 hp) Voltage fluctuations . . . . . . up to +/-- 10 % Start-up frequency . . . . . . . up to 20 / h Min. standstill time . . . . . . . 3 min Motor ... Shaft stainless steel AISI 304 SS Bearing housing stainless steel AISI 304 SS Stator case stainless steel AISI 304 SS Temperatures The UPA 100 C submersible borehole pump is designed for use in water with temperatures of up to +30 °C. Permissible Cable Lengths Direction of Rotation of the Pump ∆U up to 3 %, d.o.l starting and t up to +30 °C. Current / Voltage Clockwise rotation (viewed at the drive shaft end). Pump End (Discharge Nozzle) UPA 100C 10 -- 16 -- 22: Rp 11/2’’ 35 -- 60 Rp 2’’ 3~ / 460V Installation Vertical or horizontal installation without restriction. In order to guarantee the dissipation of the motor driving heating. It will be necessary to install a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) in horizontal installation. Motorrating kW Motorrating hp 0.75 1.10 1.50 Cable lengths for cable cross-section in ... mm2 1.5 2.5 4.0 6.0 1.02 1.50 2.04 352 m 262 m 203 m 587 m 437 m 339 m -700 m 542 m ---- 2.20 3.00 3.70 4.00 3.00 4.08 5.03 5.44 154 m 118 m 97 m 84 m 258 m 197 m 161 m 140 m 413 m 316 m 259 m 224 m 619 m 474 m 388 m 336 m 5.50 7.50 7.48 10.2 62 m 48 m 104 m 80 m 167 m 128 m 251 m 192 m Variants Available on Request ---- Higher medium temperatures Voltages above 500 V Other frequencies 23 60 Hz UPA 100C Design Features Optimised operating costs: Check valve, built into the discharge chamber, designed for low loss of head. Resistance to corrosion and abrasion, i.e. the same inherent qualities of stainless steel. Hydraulic profiles are optimized for the attainment of high efficiencies. Oversized intermediate bearings located at each pump stage to align the shaft, specially designed to optimize lubrication. Coupling and flange suitable for motors with pump mounting dimensions in accordance with NEMA standards. 24 Reliable in service: Very strong construction: minimum thickness of stainless sheet steel of 1 mm, 6 spot welding on each vane, special top bearing for every pump. Friendly service: Great ease of dismantling and assembly. Easy-to-replace wear-rings and bearings. 60 Hz UPA 100C UPA 100C 10 -- ... D1 UPA 100C 10 -- ... 62 (Tolerances to ISO 2548 Class C, Annex B) 54 (3.86 inch) 48 41 34 27 21 (3.75 inch) Ø D1 max: Pump = 96.5 mm Pump with motor = 98.0 mm 15 12 9 Rated power (Motor) Rated power (Motor) Pump unit UPA 100C 10 --.. PN kW PN hp Rated current for 3~ 460 V IN 1) A 6 9 12 15 21 0.37 0.37 0.55 0.75 1.1 0.50 0.50 0.75 1.00 1.50 1.5 1.5 2.1 2.4 3.1 27 1.5 2.00 4.1 34 2.2 3.00 5.6 41 3.7 5.00 8.7 48 3.7 5.00 8.7 54 3.7 5.00 8.7 62 3.7 5.00 8.7 1) Capacitor run motors (PSC motors) with starter. 6 Capacity m3/h Operating range: 1.1 -- 3.2 (5.0 -- 14.0 US GPM) Qmin = 1.1 m3/h (5.0 US GPM) Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers 3~ / 460 V Pump unit UPA 100C 10 --.. 6 9 12 15 21 27 34 41 48 54 62 A ≈ inches A ≈ mm B ≈ inches B ≈ mm C ≈ inches C ≈ mm Ident. No. mA ≈ kg 13.74 16.57 19.45 22.28 27.99 34.09 40.31 46.97 53.62 63.11 65.98 349 421 494 566 711 866 1024 1193 1362 1603 1676 9.53 9.53 10.66 11.75 11.75 13.62 16.06 22.20 22.20 22.20 22.20 242 242 271 298 298 346 408 564 564 564 564 23.27 26.10 30.11 34.03 39.74 47.74 56.37 69.17 75.82 80.54 85.30 591 663 765 864 1009 1212 1432 1747 1926 2046 2167 90 065 337 90 065 338 90 065 339 90 065 340 90 065 341 90 065 342 90 065 343 90 065 344 90 065 345 90 065 346 90 065 347 12.1 13.2 15.6 18.1 20.1 24.0 29.7 41.2 43.8 45.1 49.1 For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. 25 60 Hz UPA 100C UPA 100C 16 -- ... D1 UPA 100C 16 -- ... 62 (Tolerances to ISO 2548 Class C, Annex B) (3.86 inch) 51 41 31 24 (3.75 inch) Ø D1 max: 18 Pump = 96.5 mm Pump with motor = 98.0 mm 14 10 Pump unit UPA 100C 16 --.. Rated power (Motor) Rated power (Motor) PN kW PN hp 8 Rated current for 3~ 460 V IN 1) A 5 5 0.37 0.50 1.5 8 0.55 0.75 2.1 10 0.75 1.00 2.4 14 1.10 1.50 3.1 18 1.50 2.00 4.1 24 2.20 3.00 5.6 31 3.70 5.00 8.7 41 3.70 5.00 8.7 51 5.50 7.50 13.1 62 5.50 7.50 13.1 1) Capacitor run motors (PSC motors) with starter. Capacity m3/h Operating range: 2.2 -- 4.5 (10 -- 20 US GPM) Qmin = 2.2 m3/h (10 US GPM) Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers 3~ / 460 V Pump unit UPA 100C 16 --.. 5 8 10 14 18 24 31 41 51 62 A ≈ inches A ≈ mm B ≈ inches B ≈ mm C ≈ inches C ≈ mm Ident. No. mA ≈ kg 12.79 15.63 16.81 21.34 25.12 30.83 37.48 46.97 55.50 65.98 325 397 427 542 638 783 952 1193 1410 1676 9.53 10.66 11.75 11.75 13.62 16.06 22.20 22.20 28.20 28.20 242 271 298 298 346 408 564 564 716 716 18.32 26.29 28.56 33.09 38.74 46.89 59.68 69.17 83.69 94.16 567 668 725 840 984 1191 1516 1757 2126 2392 90 065 348 90 065 349 90 065 350 90 065 351 90 065 352 90 065 353 90 065 354 90 065 355 90 065 356 90 065 357 11.7 14.2 16.2 17.6 20.9 26.1 37.7 41.2 50.4 54.0 For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. 26 60 Hz UPA 100C UPA 100C 22 -- ... D1 UPA 100C 22 -- ... (Tolerances to ISO 2548 Class C, Annex B) 60 (3.86 inch) 47 39 31 26 (3.75 inch) Ø D1 max: 19 Pump = 96,5 mm Pump with motor = 98,0 mm Pump unit UPA 100C 22 --.. Rated power (Motor) Rated power (Motor) PN kW PN hp 13 7 Rated current for 3~ 460 V IN 1) A 4 10 6 4 0.37 0.50 1.5 6 0.55 0.75 2.1 7 0.75 1.00 2.4 10 1.10 1.50 3.1 13 1.50 2.00 4.1 19 2.20 3.00 5.6 26 3.70 5.00 8.7 31 3.70 5.00 8.7 39 5.50 7.50 13.1 47 5.50 7.50 13.1 60 7.50 10.0 17.0 1) Capacitor run motors (PSC motors) with starter. Capacity Operating range: 2.2 -- 6.8 m3/h (10 -- 30 US GPM) Qmin = 2.2 m3/h (10 US GPM) Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers 3~ / 460 V Pump unit UPA 100C 22 --.. 4 6 7 10 13 19 26 31 39 47 60 A ≈ inches A ≈ mm B ≈ inches B ≈ mm C ≈ inches C ≈ mm Ident. No. mA ≈ kg 11.85 13.74 14.68 16.81 20.39 26.06 32.72 37.48 45.08 52.68 64.10 301 349 373 427 518 662 831 952 1145 1338 1628 9.53 10.66 11.75 11.75 13.62 16.06 22.20 22.20 28.20 28.20 30.47 242 271 298 298 346 408 564 564 716 716 774 21.37 24.40 26.43 28.56 34.01 42.12 54.92 59.68 73.28 80.88 94.57 543 620 671 725 864 1070 1547 1516 1861 2054 2402 90 065 358 90 065 359 90 065 360 90 065 361 90 065 362 90 065 363 90 065 364 90 065 365 90 065 366 90 065 367 90 065 368 11.4 13.3 15.1 16.4 19.1 28.4 35.9 37.4 47.3 50.2 57.2 For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. 27 60 Hz UPA 100C UPA 100C 35 -- ... D1 UPA 100C 35 -- ... (Tolerances to ISO 2548 Class C, Annex B) 41 (3.86 inch) 36 31 26 20 16 (3.75 inch) Ø D1 max: Pump = 96,5 mm Pump with motor = 98,0 mm 12 9 5 Rated power (Motor) Rated power (Motor) Pump unit UPA 100C 35 --.. PN kW PN hp Rated current for 3~ 460 V IN 1) A 2 4 5 7 9 0.37 0.55 0.75 1.10 1.50 0.50 0.75 1.00 1.50 2.00 1.5 2.1 2.4 3.1 4.1 12 16 20 26 31 2.20 3.70 3.70 5.50 5.50 3.00 5.00 5.00 7.50 7.50 5.6 7.4 7.4 13.1 13.1 2 7 4 Capacity 36 7.50 10.0 17.0 41 7.50 10.0 17.0 1) Capacitor run motors (PSC motors) with starter. Operating range: 3.3 -- 10 m3/h (15--45 US GPM) Qmin = 3.3 m3/h (15 US GPM) Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers 3~ / 460 V Pump unit UPA 100C 35 --.. 2 4 5 7 9 12 16 20 26 31 36 41 A ≈ inches A ≈ mm B ≈ inches B ≈ mm C ≈ inches C ≈ mm Ident. No. mA ≈ kg 9.96 11.85 12.80 14.68 15.87 19.45 23.23 27.00 32.72 37.48 42.20 46.97 253 301 325 373 403 494 590 686 831 952 1072 1193 9.53 10.66 11.75 11.75 13.62 16.06 22.20 22.20 28.20 28.20 43.90 43.90 242 271 298 298 346 408 564 564 716 716 1115 1115 19.49 22.51 24.55 26.43 27.49 35.51 45.43 49.20 60.92 65.68 86.10 90.87 495 572 623 671 698 902 1154 1250 1547 1668 2187 2054 90 065 369 90 065 370 90 065 371 90 065 372 90 065 373 90 065 374 90 065 375 90 065 376 90 065 377 90 065 378 90 065 379 90 065 380 10.8 12.7 14.4 15.1 17.6 21.7 32.4 33.3 42.7 44.4 48.5 50.3 For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. 28 60 Hz UPA 100C UPA 100C 60 -- ... D1 UPA 100C 60 -- ... (Tolerances to ISO 2548 Class C, Annex B) (3.86 inch) 18 13 9 (3.75 inch) 7 Ø D1 max: Pump = 96,5 mm Pump with motor = 98,0 mm 5 4 Rated power (Motor) Rated power (Motor) Pump unit UPA 100C 60 --.. PN kW PN hp Rated current for 3 3~ 460 V IN 1) A 4 5 7 9 13 18 1.50 2.20 3.70 3.70 5.50 7.50 2.00 3.00 5.00 5.00 7.50 10.0 4.1 5.6 8.7 8.7 13.1 17.0 1) Capacitor run motors (PSC motors) with starter. Capacity Operating range: 5.5 -- 18.0 m3/h (25--80 US GPM) Qmin = 5.5 m3/h (25 US GPM) Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Dimensions / Weights / Ident. Numbers 3~ / 460 V Pump unit UPA 100C 60 --.. 4 5 7 9 13 18 A ≈ inches A ≈ mm B ≈ inches B ≈ mm C ≈ inches C ≈ mm Ident. No. mA ≈ kg 14.45 15.94 19.02 22.00 28.11 35.71 367 405 483 559 714 907 13.62 16.06 22.20 22.20 28.20 43.90 346 408 564 564 716 1115 28.07 32.01 41.22 44.21 56.30 79.62 713 813 1047 1123 1430 2022 90 065 381 90 065 382 90 065 383 90 065 384 90 065 385 90 065 386 16.2 19.8 29.7 30.5 39.5 43.4 For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. 29 60 Hz 30 UPA 100C 60 Hz Applications UPA 150C Submersible Borehole Pumps Suitable for handling clean or slightly contaminated water in applications such as: -- domestic water supply for Well Diameters of 150 mm (6 inches) -- general water supply -- irrigation and spray irrigation systems -- artificial lowering of the ground water level as well as -- heat transfer plants In addition, the pump sets are used in pressure boosting systems, air-conditioning systems, fountains, etc. Permissible sand content in the fluid handled: 50 g/m3. Operating Data Capacity . . . . . . . . . . . . . . . . . . Head . . . . . . . . . . . . . . . . . . . . . Temperature of fluid handled . Speed . . . . . . . . . . . . . . . . . . . . Q H t n up to 93 m3/h (26 l/s) up to 730 m up to 50 °C 3500 rpm Design Multistage centrifugal pump with components made of stainless steel and additional bearing for each stage. The stage casings are connected by means of tie bolts. Motor Canned or wet submersible squirrel-cage motor, 2 poles; NEMA shaft end; 60 Hz; type of enclosure: IP 68 Designation (Example) UPA 150 C -- 16 / 9 Type series Minimum well diameter (mm) Design status Capacity (m3/h) Number of stages Certification Quality management certified to ISO 9001 Product Features -- Rust-proof -- Suitable for installation in narrow deep wells -- High efficiency -- Motor designed for maximum pump output -- Low noise level -- For vertical, angled or horizontal installation -- Check valve with anti-blockage valve disc 31 2 60 Hz UPA 150C Selection Charts (Ranges on Offer) n ≈ 3500 rpm UPA 150C -- 60 UPA 150C -- 16 UPA 150C -- 30 UPA 150C -- 48 UPA 150C -- 16 UPA 150C -- 30 32 UPA 150C -- 48 UPA 150C -- 60 60 Hz Material Variants Bearings / Lubrication Material Component UPA 150C C1 (AISI 304) C2 (AISI 316) Radial plain bearings: pump bearings lubricated by the fluid handled, motor bearings by the motor’s water fill. Axial thrust is balanced by a tilting-pad thrust bearing in the motor (lower end). Pump Suction casing Direction of Rotation of the Pump 1.4408 Stage casing 1.4301 1.4404 Stage casing with hole 1.4301 1.4404 Upper stage casing 1.4301 1.4404 Suction strainer 1.4401 1.4404 Flanged end piece 1.4408 Shaft 1.4305 1.4401 Impeller 1.4301 1.4404 Thrust bearing HY22 Counter thrust bearing A2 A4 O-ring NBR Casing wear ring NBR Impeller wear ring 1.4301 1.4404 Bearing bush NBR Disc 1.4301 1.4404 Valve body 1.4408 Valve spring 1.4401 Valve plate 1.4404 Coupling 1.4308 1.4408 Tiebolt 1.4301 1.4404 Hexagon socket head screw A2 A4 Hexagon socket head screw A4 A4 Nut A2 A4 Impeller nut 1.4401 Locking sleeve 1.4401 Clamp 1.4301 1.4404 Cable support 1.4301 1.4404 Protection plug HY22 Material C Component t C1 (AISI 304) C2 (AISI 316) 1.4305 1.4462 1.4301 1.4401 JL--1030 1.4409 1.4301 1.4571 Motor Shaft Bearing carrier Stator case DN 100 UMA 150D Description 1.4301 1.4305 1.4308 1.4401 1.4404 1.4408 1.4462 1.4571 JL -- 1030 A2 A4 HY22 NBR CrNi steel CrNi steel CrNi steel CrNiMo steel CrNiMo steel CrNiMo steel CrNiMo steel CrNiMo steel cast iron CrNi steel CrNiMo steel Carbon/graphite in PTFE Acrylnitril--Butadien--Kautschuk Clockwise rotation (when looking at the drive shaft end). Pump End (Discharge) UPA 150C submersible borehole pumps can be supplied with the following discharge ends: G 21/2” G 3” G 4” DN 50 DN 65 DN 80 UPA 150C -- 16 x x -- x x x UPA 150C -- 30 -- x x -- x x UPA 150C -- 48 -- x x -- x x UPA 150C -- 60 -- x x -- x x Coating (Bearing carrier) UMA 150D motor: Quality . . . . . . . . . . . powder coating, approved for drinking water contact Type of Installation Standard vertical installation. Depending on the number of stages, horizontal installation is also possible. Motor DN 100: In order to guarantee the dissipation of the motor heat it will be necessary to install a device guiding the flow along the motor (cooling jacket, flow inducer sleeve, etc.) in horizontal installation. Drive Design . . . . . . . . . . . . . . Canned 1) or wet 2) submersible squirrel-cage motor, 2 poles Connection . . . . . . . . . . NEMA standard Type of enclosure . . . . IP 68 Frequency f . . . . . . . . . . 60 Hz Type of current . . . . . . . three-phase (3 ~) Rated voltage U . . . . . . up to 460V Rated power PN . . . . . . . . up to 44 kW Frequency of starts . . . 20 / h 1) and 15 / h 2) Minimum delay before restarting . . . . . . 1 min 1) or 2 min 2) Motor design is in compliance with VDE regulations. 1) Motor DN 100 2) Motor UMA 150D Connection to Power Supply The submersible motors are supplied ex factory with 1 or 2 motor leads, each equipped with an earth conductor. All motors are provided with internal earthing. Any extension cables required are connected using water-tight cable connectors. Motor leads and extension cables are suitable for drinking water applications. 33 4 60 Hz Starting Motor DN 100 . . . . . d.o.l. only (autotransformer or soft starter) Motor UMA 150D . . d.o.l. (autotransformer or soft starter) or star-delta Variable Speed The submersible borehole pumps can also be equipped with a speed control system to accommodate different operating points. Application Temperatures The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = + 30 °C. An indispensable requirement for this is a flow velocity of v = 0.5 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = + 50 °C or for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.). Variants Available on Request -- Other supply voltages up to 1000 V -- Models with cooling, suction or pressure shroud 34 UPA 150C 60 Hz UPA 150C Design Features of the pump Corrosion resistance The pump and motor are constructed of high--grade stainless steel as standard -- producing consistently high efficiency levels. Also available in higher grade CrNiMo steel for aggressive fluids. Low operating costs High efficiency and low--loss check valve maintain long--term energy savings over the entire service lifetime of the unit. Maintenance--friendly design D Simple disassembly and reassembly D Rewindable motors Flexibility D Exchangeable connection variants D Check valve can be removed easily D Suitable for vertical installation in deep wells or horizontal installation D NEMA connection High operating reliability and long service life Equipped with reinforced suction strainer, robust drive lantern and check valve made of investment cast stainless steel. Laser--welded impellers. Protected against thrust reversal. Hygienic and approved for drinking water ACS approved 35 6 60 Hz UPA 150C Design Features of the motor UMA 150D The KSB motor -- VDE-compliant, i.e., high level of electrical safety. -- Designed for max. pump power to protect unit from overloads. Dynamically balanced rotor -- Ensures smooth running. Counter thrust bearing -- Reliable balancing of negative axial thrust. -- Impellers do not rub on the stage casings. Tried and tested thrust bearing -- Water-lubricated self-aligning tilting-pad journal bearing. -- No-maintenance design suitable for maximum load-carrying capacity under continuous operation conditions. -- New materials combination (stainless steel / carbon) for high safety factor. 36 60 Hz UPA 150C 37 8 60 Hz UPA 150C -- 16 / ...; number of stages 1 -- 15 The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve ηp: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 21/2” The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) Dmax (mm) G 21/2” 40 G 3” 48 G 4” 93 DN 50 77 165 DN 65 77 185 DN 80 77 200 see page 41 Threaded end to DIN ISO 228, Part 1. Flange end to DIN 2501, Part 1 G 21/2” Dmax Lp LA 38 UPA 150C 60 Hz UPA 150C UPA 150C -- 16 / ...; number of stages 16 -- 45 The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve ηp: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 21/2” The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) Dmax (mm) G 21/2” 40 G 3” 48 G 4” 93 DN 50 77 165 DN 65 77 185 DN 80 77 200 see page 41 Threaded end to DIN ISO 228, Part 1. Flange end to DIN 2501, Part 1 G 21/2” Dmax Lp LA 39 0 60 Hz UPA 150C Technical Data Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid pumped v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) H0 m PN kW PN hp tmax 1) _C IN A ηM % cos ϕ ---- d.o.l. mm2 Y-∆ mm2 1 + DN 100 - 1.1 15.6 1.3 1.7 30 2.9 74.0 0.77 4 x 1.5 -- 2 + DN 100 - 2.2 31 2.5 3.4 30 5.6 77.0 0.77 4 x 1.5 -- 3 + DN 100 - 3.0 47 3.4 4.6 30 7.4 79.0 0.76 4 x 1.5 -- 4 + DN 100 - 3.7 64 4.2 5.6 30 8.7 78.0 0.79 4 x 1.5 -- 5 + UMA 150D 5/21 82 5.5 7.4 42 12.1 75.5 0.79 4 x 2.5 3/4 x 2.5 6 + UMA 150D 5/21 98 6.5 8.7 39 13.6 75.5 0.83 4 x 2.5 3/4 x 2.5 7 + UMA 150D 7/21 115 7.5 10.1 40 15.6 77.5 0.81 4 x 2.5 3/4 x 2.5 8 + UMA 150D 9/21 131 8.5 11.4 40 17.4 79.0 0.80 4 x 2.5 3/4 x 2.5 9 + UMA 150D 9/21 147 9.5 12.7 38 19.0 78.5 0.82 4 x 2.5 3/4 x 2.5 10 + UMA 150D 9/21 162 10.0 13.4 35 19.8 78.5 0.83 4 x 2.5 3/4 x 2.5 11 + UMA 150D 13/21 181 11.5 15.4 41 23.0 82.0 0.77 4 x 2.5 3/4 x 2.5 12 + UMA 150D 13/21 197 12.5 16.8 40 24.5 82.0 0.79 4 x 2.5 3/4 x 2.5 13 + UMA 150D 13/21 212 13.5 18.1 38 26.0 82.0 0.81 4 x 2.5 3/4 x 2.5 14 + UMA 150D 13/21 228 14.5 19.4 37 27.5 81.5 0.82 4 x 2.5 3/4 x 2.5 15 + UMA 150D 13/21 243 15.0 20.1 35 28.5 81.5 0.82 4 x 2.5 3/4 x 2.5 16 + UMA 150D 13/21 258 15.6 20.9 33 29.0 81.5 0.83 4 x 2.5 3/4 x 2.5 17 + UMA 150D 15/21 275 17.0 22.8 35 31.0 82.5 0.84 4 x 4.0 3/4 x 2.5 18 + UMA 150D 15/21 291 18.0 24.1 34 33.0 82.0 0.84 4 x 4.0 3/4 x 2.5 19 + UMA 150D 18/21 310 20.0 26.8 36 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5 20 + UMA 150D 18/21 325 20.0 26.8 34 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5 21 + UMA 150D 18/21 340 21.0 28.2 33 39.0 83.0 0.82 4 x 4.0 3/4 x 2.5 22 + UMA 150D 18/21 356 22.0 29.5 31 40.5 82.5 0.83 4 x 4.0 3/4 x 2.5 23 + UMA 150D 22/21 376 24.0 32.2 37 44.0 84.5 0.81 4 x 4.0 3/4 x 2.5 24 + UMA 150D 22/21 391 25.0 33.5 36 45.5 84.5 0.82 4 x 4.0 3/4 x 2.5 25 + UMA 150D 22/21 406 25.0 33.5 35 45.5 84.5 0.82 4 x 4.0 3/4 x 2.5 26 + UMA 150D 22/21 421 26.0 34.9 34 47.0 84.5 0.83 4 x 4.0 3/4 x 2.5 27 + UMA 150D 22/21 437 26.4 35.4 33 47.5 84.5 0.83 4 x 4.0 3/4 x 2.5 28 + UMA 150D 26/21 457 29.0 38.9 38 52.0 85.5 0.83 4 x 6.0 3/4 x 4.0 29 + UMA 150D 26/21 472 30.0 40.2 37 54.0 85.5 0.83 4 x 6.0 3/4 x 4.0 30 + UMA 150D 26/21 487 30.0 40.2 36 54.0 85.5 0.83 4 x 6.0 3/4 x 4.0 33 + UMA 150D 30/21 540 34.0 45.6 37 62.0 86.0 0.82 4 x 6.0 3/4 x 4.0 36 + UMA 150D 30/21 585 36.0 48.3 35 64.0 85.5 0.83 4 x 6.0 3/4 x 4.0 39 + UMA 150D 37/22 635 40.0 53.6 48 72.0 85.0 0.82 3/4 x 4.0 3) 3/4 x 4.0 42 + UMA 150D 37/22 682 42.0 56.3 46 76.0 85.0 0.83 3/4 x 4.0 3) 3/4 x 4.0 0.84 3) 3/4 x 4.0 UPA 150C -- 16 / ... 45 + UMA 150D 37/22 1) also see page 34 40 727 44.0 59.0 2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing. 43 3) Parallel cable 78.0 85.0 3/4 x 4.0 60 Hz UPA 150C Dimensions / Weights / Horizontal Installation 1) UPA 150C -- 16 / ... LP mm LA ≈ mm mA in ≈ kg g Dmax in ≈ mm Installation 2)3) C1 (AISI 304) C2 (AISI 316) d.o.l. Y-∆ 1 337 635 635 17 139 -- v 3) 2 397 755 755 21 139 -- v 3) 3 458 880 880 25 139 -- v 3) 4 518 1075 1075 34 139 -- v 3) 5 611 1310 1310 62 148 148 v+h 6 671 1370 1370 63 148 148 v+h 7 732 1455 1450 66 148 148 v+h 8 792 1545 1540 71 148 148 v+h 9 853 1605 1600 72 148 148 v+h 10 913 1665 1660 73 148 148 v+h 11 974 1805 1805 82 148 148 v+h 12 1034 1865 1865 83 148 148 v+h 13 1095 1925 1925 85 148 148 v+h 14 1155 1985 1985 86 148 148 v+h 15 1216 2045 2045 87 148 148 v+h 16 1276 2105 2105 89 148 148 v+h 17 1337 2215 2210 94 148 148 v+h 18 1397 2275 2270 95 148 148 v+h 19 1458 2380 2375 101 148 148 v+h 20 1518 2440 2435 102 148 148 v+h 21 1579 2500 2500 103 148 148 v+h 22 1639 2560 2560 105 148 148 v+h 23 1700 2710 2710 114 148 148 v+h 24 1760 2770 2770 116 148 148 v+h 25 1821 2830 2830 117 148 148 v+h 26 1881 2890 2890 118 148 148 v+h 27 1942 2955 2950 120 148 148 v+h 28 2002 3120 3115 130 149 149 v 3) 29 2063 3180 3175 131 149 149 v 3) 30 2123 3240 3235 133 149 149 v 3) 33 36 39 on request q 42 45 1) Including check valve with threaded end and standard motor leads. 2) v = vertical / h = horizontal. 3) horizontale installation on request 41 2 60 Hz UPA 150C -- 30 / ...; number of stages 1 -- 13 The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve ηp: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 3” The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) Dmax (mm) G 21/2” 40 G 3” 48 G 4” 93 DN 50 77 165 DN 65 77 185 DN 80 77 200 see page 45 Threaded end to DIN ISO 228, Part 1. Flange end to DIN 2501, Part 1 G 3’’ Dmax Lp LA 42 UPA 150C 60 Hz UPA 150C UPA 150C -- 30 / ...; number of stages 14 -- 23 The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve ηp: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 3” The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) Dmax (mm) G 21/2” 40 G 3” 48 G 4” 93 DN 50 77 165 DN 65 77 185 DN 80 77 200 see page 45 Threaded end to DIN ISO 228, Part 1. Flange end to DIN 2501, Part 1 G 3’’ Dmax Lp LA 43 4 60 Hz UPA 150C Technical Data Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) tmax 1) _C IN A ηM % cos ϕ ---- d.o.l. mm2 Y-∆ mm2 H0 m PN kW 1 + DN 100 - 1.5 15.6 1.8 30 4.1 74.0 0.80 4 x 1.5 -- 2 + DN 100 - 3.0 31.0 3.4 30 7.4 79.0 0.76 4 x 1.5 -- 3 + UMA 150D 5/21 49.0 5.0 43 11.4 75.0 0.77 4 x 2.5 3/4 x 2.5 4 + UMA 150D 5/21 64.0 6.5 39 13.6 75.5 0.83 4 x 2.5 3/4 x 2.5 5 + UMA 150D 7/21 80.0 8.0 38 16.4 77.0 0.82 4 x 2.5 3/4 x 2.5 6 + UMA 150D 7/21 95.0 9.0 33 18.0 76.5 0.84 4 x 2.5 3/4 x 2.5 UPA 150C -- 30 / ... PN hp Max. temperature of the fluid pumped v ≥ 0.5 m/s 7 + UMA 150D 9/21 111.0 11.0 33 21.0 78.0 0.84 4 x 2.5 3/4 x 2.5 8 + UMA 150D 13/21 129.0 12.5 39 24.5 82.0 0.79 4 x 2.5 3/4 x 2.5 9 + UMA 150D 13/21 144.0 14.0 37 26.5 82.0 0.81 4 x 2.5 3/4 x 2.5 10 + UMA 150D 13/21 159.0 15.5 34 29.0 81.5 0.83 4 x 2.5 3/4 x 2.5 11 + UMA 150D 15/21 176.0 17.0 36 31.0 82.5 0.84 4 x 4.0 3/4 x 2.5 12 + UMA 150D 15/21 190.0 18.0 33 33.0 82.0 0.84 4 x 4.0 3/4 x 2.5 13 + UMA 150D 18/21 208.0 20.0 34 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5 14 + UMA 150D 18/21 223.0 22.0 32 40.5 82.5 0.83 4 x 4.0 3/4 x 2.5 15 + UMA 150D 22/21 241.0 24.0 37 44.0 84.5 0.81 4 x 4.0 3/4 x 2.5 16 + UMA 150D 22/21 256.0 25.0 36 45.5 84.5 0.82 4 x 4.0 3/4 x 2.5 17 + UMA 150D 22/21 271.0 26.0 34 47.0 84.5 0.83 4 x 4.0 3/4 x 2.5 18 + UMA 150D 26/21 289.0 28.0 38 51.0 85.5 0.82 4 x 6.0 3/4 x 4.0 19 + UMA 150D 26/21 304.0 30.0 37 54.0 85.5 0.83 4 x 6.0 3/4 x 4.0 20 + UMA 150D 26/21 319.0 31.0 36 55.0 85.5 0.84 4 x 6.0 3/4 x 4.0 21 + UMA 150D 30/21 338.0 33.0 38 60.0 86.0 0.81 4 x 6.0 3/4 x 4.0 22 + UMA 150D 30/21 353.0 34.0 37 62.0 86.0 0.82 4 x 6.0 3/4 x 4.0 23 + UMA 150D 30/21 368.0 36.0 36 64.0 85.5 0.83 4 x 6.0 3/4 x 4.0 1) also see page 34 44 2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing. 60 Hz UPA 150C Dimensions / Weights / Horizontal Installation 1) UPA 150C -- 30 / ... LP mm mA ≈ kg g LA ≈ mm Dmax ≈ mm Installation 2) C1 (AISI 304) C2 (AISI 316) d.o.l. Y-∆ 1 389 715 715 20 139 -- v 3) 2 485 910 910 25 139 -- v 3) 3 613 1315 1310 60 146 148 v+h 4 709 1410 1410 61 146 148 v+h 5 805 1525 1525 65 146 148 v+h 6 901 1620 1620 67 146 148 v+h 7 997 1750 1745 71 146 148 v+h 8 1093 1925 1920 80 146 148 v+h 9 1189 2020 2020 81 146 148 v+h 10 1285 2115 2115 83 146 148 v+h 11 1381 2255 2255 88 147 148 v+h 12 1477 2355 2350 90 147 148 v+h 13 1573 2495 2490 96 147 148 v+h 14 1669 2590 2590 97 147 148 v+h 15 1765 2775 2775 107 147 148 v+h 16 1861 2870 2870 108 147 148 v+h 17 1957 2970 2965 110 147 148 v+h 18 2053 3170 3165 121 149 149 v 3) 19 2149 3265 3265 122 149 149 v 3) 20 2245 3360 3360 124 149 149 v 3) 21 2341 3555 3555 134 149 149 v 3) 22 2437 3655 3650 136 149 149 v 3) 23 2533 3750 3745 138 149 149 v 3) 1) Including check valve with threaded end and standard motor leads. 2) v = vertical / h = horizontal. 3) horizontale installation on request 45 6 60 Hz UPA 150C -- 48 / ...; number of stages 1 -- 14 The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve ηp: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 3” The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) Dmax (mm) G 21/2” 40 G 3” 48 G 4” 93 DN 50 77 165 DN 65 77 185 DN 80 77 200 see page 47 Threaded end to DIN ISO 228, Part 1. Flange end to DIN 2501, Part 1 G 3’’ Dmax Lp LA 46 UPA 150C 60 Hz UPA 150C Technical Data Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid pumped v ≥ 0.5 m/s Rated current Efficiency Power factor tmax 1) _C IN A ηM % cos ϕ ---- d.o.l. mm2 H0 m PN kW 1 + DN 100 - 3.0 19.2 3.4 30 7.4 79.0 0.76 4 x 1.5 -- 2 + UMA 150D 5/21 40.0 6.0 41 12.9 75.5 0.81 4 x 2.5 3/4 x 2.5 3 + UMA 150D 7/21 59.0 8.5 36 17.2 77.0 0.83 4 x 2.5 3/4 x 2.5 4 + UMA 150D 9/21 79.0 11.0 33 21.0 78.0 0.84 4 x 2.5 3/4 x 2.5 5 + UMA 150D 13/21 100.0 14.0 37 26.5 82.0 0.81 4 x 2.5 3/4 x 2.5 6 + UMA 150D 15/21 119.0 16.5 36 30.5 82.5 0.83 4 x 4.0 3/4 x 2.5 7 + UMA 150D 18/21 140.0 20.0 35 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5 8 + UMA 150D 18/21 158.0 22.0 31 40.5 82.5 0.83 4 x 4.0 3/4 x 2.5 9 + UMA 150D 22/21 179.0 25.0 36 45.5 84.5 0.82 4 x 4.0 3/4 x 2.5 10 + UMA 150D 26/21 200.0 28.0 38 51.0 85.5 0.82 4 x 6.0 3/4 x 4.0 11 + UMA 150D 26/21 218.0 31.0 36 55.0 85.5 0.84 4 x 6.0 3/4 x 4.0 12 + UMA 150D 30/21 240.0 34.0 37 62.0 86.0 0.82 4 x 6.0 3/4 x 4.0 13 + UMA 150D 30/21 258.0 36.0 35 64.0 85.5 0.83 4 x 6.0 3/4 x 4.0 14 + UMA 150D 37/22 279.0 40.0 48 72.0 85.0 0.82 3/4 x 4.0 3) 3/4 x 4.0 UPA 150C -- 48 / ... 1) also see page 34 PN hp Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) 2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing. Y-∆ mm2 3) Parallel cable Dimensions / Weights / Horizontal Installation 1) UPA 150C -- 48 / ... LP mm LA ≈ mm C1 (AISI 304) mA ≈ kg C2 (AISI 316) Dmax ≈ mm d.o.l. Installation 2) Y-∆ 1 406 830 830 26 139 -- v+h 2 551 1250 1250 61 143 146 v+h 3 664 1385 1385 65 143 146 v+h 4 777 1530 1525 71 143 146 v+h 5 890 1720 1720 80 143 146 v+h 6 1003 1880 1875 86 145 146 v+h 7 1116 2035 2035 92 145 146 v+h 8 1229 2150 2150 95 145 146 v+h 9 1342 2355 2350 105 145 146 v+h 10 1455 2570 2570 116 146 147 v+h 11 1568 2685 2680 119 146 147 v+h 12 1681 2895 2895 130 146 147 v+h 13 1794 3010 3010 132 146 147 v 3) 14 1907 3205 3200 141 146 147 v 3) 1) Including check valve with threaded end and standard motor leads. 2) v = vertical / h = horizontal. 3) horizontale installation on request 47 8 60 Hz UPA 150C -- 60 / ...; number of stages 1 -- 11 The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve ηp: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 3” The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) Dmax (mm) G 21/2” 40 G 3” 48 G 4” 93 DN 50 77 165 DN 65 77 185 DN 80 77 200 see page 49 Threaded end to DIN ISO 228, Part 1. Flange end to DIN 2501, Part 1 G 3’’ Dmax Lp LA 48 UPA 150C 60 Hz UPA 150C Technical Data Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid pumped v ≥ 0.5 m/s Rated current Efficiency Power factor tmax 1) _C IN A ηM % cos ϕ ---- d.o.l. mm2 H0 m PN kW 1 + DN 100 - 3.0 19.4 3.4 30 7.4 79.0 0.76 4 x 1.5 -- 2 + UMA 150D 5/21 40.0 6.6 37 13.8 75.5 0.83 4 x 2.5 3/4 x 2.5 3 + UMA 150D 9/21 60.0 10.0 36 19.8 78.5 0.83 4 x 2.5 3/4 x 2.5 4 + UMA 150D 13/21 81.0 13.5 38 26.0 82.0 0.81 4 x 2.5 3/4 x 2.5 5 + UMA 150D 15/21 101.0 16.5 36 30.5 82.5 0.83 4 x 4.0 3/4 x 2.5 6 + UMA 150D 18/21 121.0 20.0 34 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5 7 + UMA 150D 22/21 142.0 24.0 37 44.0 84.5 0.81 4 x 4.0 3/4 x 2.5 8 + UMA 150D 22/21 161.0 26.4 34 47.5 84.5 0.83 4 x 4.0 3/4 x 2.5 9 + UMA 150D 26/21 182.0 30.0 37 54.0 85.5 0.83 4 x 6.0 3/4 x 4.0 10 + UMA 150D 30/21 203.0 34.0 37 62.0 86.0 0.82 4 x 6.0 3/4 x 4.0 11 + UMA 150D 37/22 223.0 38.0 50 69.0 85.5 0.81 3/4 x 4.0 3) 3/4 x 4.0 UPA 150C -- 60 / ... 1) also see page 34 PN hp Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) 2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing. Y-∆ mm2 3) Parallel cable Dimensions / Weights / Horizontal Installation 1) UPA 150C -- 60 / ... LP mm mA ≈ kg g LA ≈ mm C1 (AISI 304) C2 (AISI 316) Dmax ≈ mm d.o.l. Y-∆ Installation 2) 1 406 830 830 25 139 -- v+h 2 551 1250 1250 61 143 146 v+h 3 664 1415 1415 68 143 146 v+h 4 777 1610 1605 78 143 146 v+h 5 890 1765 1765 84 145 146 v+h 6 1003 1925 1920 90 145 146 v+h 7 1116 2125 2125 100 145 146 v+h 8 1229 2240 2240 103 145 146 v+h 9 1342 2460 2455 114 146 147 v+h 10 1455 2670 2670 125 146 147 v+h 11 1568 2865 2860 134 145 147 v 3) 1) Including check valve with threaded end and standard motor leads. 2) v = vertical / h = horizontal. 3) horizontale installation on request 49 0 60 Hz 50 UPA 150C UPA 200, 200B, 250C 60 Hz Applications Submersible Borehole Pumps Handling clean or slightly contaminated water ... -- in general water supply systems, -- in irrigation and spray irrigation systems, -- in pressure boosting systems, -- in emergency water supply systems, -- in installations for lowering and maintaining ground water levels. for Well Diameters of 200 mm (8 inches) and Above and of 250 mm (10 inches) and Above Also used in ... -- mining, -- sprinkler installations, -- fountains etc Permissible sand content in the fluid handled: 50 g/m3. Also suitable for aggressive seawater if supplied in material variant C3 (duplex). Operating Data Capacity . . . . . . . . . . . . . . . . . . . Q up to 400 m3/h (111 l/s or up to 1600 US GPM) Head . . . . . . . . . . . . . . . . . . . . . . H up to 434 m Temperature of fluid handled . . t up to +50 °C Speed . . . . . . . . . . . . . . . . . . . . . n ≈ 3500 rpm Design Single or multistage, single-entry centrifugal pumps in ring-section design. Mixed flow hydraulic systems with impellers that can be turned down. Stage casings connected by means of studs. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with non-return valve or connection branch on option. Both models available with either threaded or flanged end. Particularly suitable for vertical installation in narrow deep wells. Designation (Example) UPA 200 B -- 80 B / 5 d Type series Minimum well diameter (mm) (for ex.: 200 mm = 8 inches) Design status Capacity Qopt for 50 Hz (m3/h) Impeller material1) without code letter: with code B: execution G execution B Number of stages Reduced impeller diameters 1) Applies to UPA 200B only. Certification Product Features --------- Very sturdy design Suitable for installation in narrow deep wells High efficiency Motor designed for maximum pump output Low noise level For vertical or horizontal installation Non-return valve protected against blocking Pre-filled motor; no risk of contamination of the handled water Quality management certified to ISO 9001 51 60 Hz UPA 200, 200B, 250C Selection Chart (Ranges on Offer) n ≈ 3500 rpm UPA 250C -- 120 UPA 250C -- 250 UPA 200B -- 80 UPA 200 -- 11 UPA 250C -- 150 UPA 200 -- 14 UPA 200B -- 130 UPA 200-14 UPA 250C-120 UPA 200B-80 UPA 200-11 UPA 250C-250 UPA 200B-130 UPA 250C-150 Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this range. The operating ranges ∆QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages. Selection charts or performance curves for UPA in material variant C3 (duplex) on request only. 52 UPA 200, 200B, 250C 60 Hz UPA 200 Threaded End Flanged End Material Variants Component Execution G Casing Cast iron Bronze (JL1030) 1) (CC480K--GS) 2) Glass fibre reinforced NORYL (PPO) Glass fibre reinforced NORYL (PPO) Cr steel CrNiMo steel (1.4021) (1.4462) CrNiMo steel (1.4401) CrNiMo steel (A4-70) Impeller Diffuser Shaft Wear ring Screws, bolts and nuts 1) DIN mat. code: GG-20 2) Execution B DIN mat. code: CuSn10 Bearings / Lubrication Plain bearing in the end stage, lubricated by the fluid handled. Axial thrust is balanced by a thrust bearing in the motor. Direction of Rotation of the Pump Clockwise rotation (when looking at the drive shaft end). Pump End (Discharge Nozzle) UPA 200 - 11 + 14: internal thread G 3’’ (DN 80). Flanged end with adapter also available (see “Accessories”). Variants Available on Request --- Pumps with flanged end Pumps with connection branch with either threaded or flanged end 3410:8/3 Example: UPA 200 - 14/3 with UMA 150D .. / 2. Part No Description 106/108 143 171 211 232 503 529/545 751 849 917 Suction casing / Stage casing Suction strainer Diffuser Pump shaft Clockwise impeller Impeller wear ring Bearing sleeve / Bearing bush Valve body Sleeve coupling Tie bolt 53 60 Hz UPA 200B, 250C Pump End (Discharge Nozzle) At choice with female thread G 5’’ and G 6’’ or flange DN 125 and DN 150 dependent on pump size. Material Variants G B UPA pump (Standard) (Special) (Duplex) Casing Cast iron (JL1040) 1) Bronze (CC480K-GS) 2) CrNiMo steel (1.4517) Impeller 200B 250C Shaft Wear ring C3 Glass fibre Bronze reinforced (CC480K-GS) 5) CrNiMo steel NORYL (1.4517) (PPO) 2) Bronze (CC480K-GS) Cr steel CrNiMo steel (1.4021) (1.4462) high-performance plastics CrNiMo steel (1.4538) CrNiMo steel (A4--70) CrNiMo steel (1.4462) Screws, bolts and nuts 4) G C2 C3 UMA motor (Standard) (Special) (Duplex) Shaft CrNi steel (1.4305) CrNiMo steel (1.4462) CrNiMo steel (1.4462) CrNiMo steel (1.4462) 150D 200D 250D 300D Housing g Stator case Screws bolts and d nuts 4) 1) 2) UPA 200, 200B, 250C 150D Cast iron (JL1030) 3) CrNiMo steel (1.4409) CrNiMo steel (1.4539) 200D 250D Cast iron (JL1030) 3) CrNiMo steel (1.4408) CrNiMo steel (1.4539) 300D Cast iron (JL1040) 1) 150D CrNi steel (1.4301) CrNiMo steel (1.4571) CrNiMo steel (1.4539) 200D 250D CrNiMo steel (1.4301) CrNiMo steel (1.4571) CrNiMo steel (1.4539) 300D CrNiMo steel (1.4301) 150D CrNi steel (1.4301) CrNiMo steel (1.4517) CrNiMo steel (1.4462) CrNiMo steel (A4--70) CrNiMo steel (1.4539) 200D 250D CrNiMo steel (A4--70) CrNiMo steel (1.4539) 300D CrNiMo steel (A4--70) CrNiMo steel (1.4462) 3) 4) 5) DIN mat. code GG-20 Wetted by fluid handled for size 80B and 130B DIN mat. code: GG-25 DIN mat. code: CuSn10 Bearings / Lubrication Radial plain bearings; lubricated by the liquid handled or by the motor filling water. Depending on the number of stages 1 intermediate bearings is fitted on the pump unit. The axial thrust is balanced by a thrust bearing with self-adjusting tilting pads in the lower part of the motor. Direction of Rotation of the Pump Clockwise rotation (when looking at the drive shaft end). 54 Coating (Standard) Quality . . . . . . . . . . . 2-component high-build coating (epoxy resin base), approved for drinking water contact Coating structure . . Primer and top coat Film thickness . . . . 100 to 150 µm Colour . . . . . . . . . . . ultramarine blue (RAL 5002) Type of Installation In general, the pumps are installed vertically. Some models may also be installed horizontally depending on the number of stages and motor size. Drive Motor type . . . . . . . . water-filled submersible squirrel-cage motor, 2 poles Type of enclosure . IP 68 Frequency . . . . . . . . 60 Hz Type of current . . . . three-phase (3~) Rated voltage U . . . 440 V ... 460 V Rated power PN . . . up to 225 kW ( 301.7 hp) Frequency of starts 15/h 1) and 10/h 2) Minimum delay before restarting . . 1 min 1) and 3 min 2) Motor design is in compliance with VDE regulations. 1) 2) Motor UMA 150D Motors UMA 200D and 250D Connection to Power Supply The motors are normally equipped ex works as follows with short flat cables ... -- UMA 150D: 1 x 4 m with 4 conductors (3 phases + 1 earth conductor) for direct starting or 1 x 4 m with 3 conductors and 1 x 4 m with 4 conductors (3 phases + 1 earth conductor) for direct and star-delta starting, -- UMA 200D + UMA 250D: 1 x 6 m with 3 conductors and 1 x 6 m with 4 conductors (3 phases + 1 earth conductor) for direct and star-delta starting. All motor sizes are equipped with internal earthing. Connection of extension cable on short cable by means of a waterproof cable connector (see ”accessories” ) Short cable and extension cable in food quality. Note: The cross-section of short cable is only designed for underwater use. For laying partially or completely in air it is necessary to check the cross-section of this cable. 60 Hz UPA 200, 200B, 250C Starting Direct on line (without or with starting transformer as well as with smooth running device) or star-delta starting. Variable Speed The submersible motor pumps can also be adjusted with a speed adjustment to different duty points. Application Temperatures The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = +30 °C. An indispensable requirement for this is a flow velocity of v = 0.5 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = +50 °C or for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.). Variants Available on Request -------- UPA 200B pumps with impellers out of Bronze other materials other or higher voltages until 6600 V other frequencies more wear resistant design pump with connection nozzle (instead of non-return valve) with cooling, suction or pressure shroud 55 60 Hz UPA 200, 200B, 250C Design Features All wetted plastic components are approved for contact drinking water (BAM 1)) -- Coating, electric cables, seal elements, gaskets, etc. are absolutely fit for use in drinking water applications. Check valve with anti-blockage valve disc -- No jamming or tilting. -- Spring-loaded design makes for minimum valve closing times and prevents waterhammer. -- High operating reliability. 1) German Federal Institute for Materials Research Robust wear rings -- Replaceable wear rings made of corrosion- and wear-resistant metal. -- Protection against wear in the clearance; easy servicing. Enclosed pump bearing -- No-maintenance design, high wear resistance. -- For trouble-free long-term operation. Energy-efficient hydraulic systems -- High efficiency and low energy costs. Integrated sand separator -- Tried and tested KSB patent. -- Added protection from abrasive wear for shafts and bearing areas. -- Long service life and high operating reliability. The KSB motor -- VDE-compliant, i.e., high level of electrical safety. -- Designed for max. pump power to protect unit from overloads. Wear-resistant mechanical seal -- Long service life and high operating reliability. Counter thrust bearing -- Reliable balancing of negative axial thrust. -- Impellers do not rub on the stage casings. 56 H04004669 Tried and tested thrust bearing -- Water-lubricated self-aligning tilting-pad journal bearing. -- No-maintenance design suitable for maximum load-carrying capacity under continuous operation conditions. -- New materials combination (stainless steel / carbon) for high safety factor. Dynamically balanced rotor -- Ensures smooth running. Reliable pressure balancing system -- Optimum rubber expansion diaphragm design. -- Enables installation at very low depths. 60 Hz UPA 200, 200B, 250C 57 60 Hz UPA 200 UPA 200 – 11 for Well Diameters of 200 mm (8 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤+30 _C) H0 m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1e + UMA 150D 5/21 1d + UMA 150D 5/21 1 + UMA 150D 5/21 26.5 29.2 32.5 4.0 4.5 5.5 5.4 6.0 7.4 45 44 42 10.1 10.7 12.1 73.5 74.6 75.5 0.71 0.74 0.79 4 x 2.5 4 x 2.5 4 x 2.5 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 2e + UMA 150D 7/21 2c + UMA 150D 7/21 2 + UMA 150D 9/21 51.9 58.6 63.9 7.5 9.0 10.5 10.1 12.1 14.1 40 35 35 15.6 18.0 20.5 77.3 76.7 78.4 0.81 0.84 0.84 4 x 2.5 4 x 2.5 4 x 2.5 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3d + UMA 150D 13/21 3 + UMA 150D 13/21 86.6 96.0 12.0 15.0 16.1 20.1 40 35 23.5 28.5 82.0 81.6 0.78 0.82 4 x 2.5 4 x 2.5 3/4 x 2.5 4) 3/4 x 2.5 4) 4c + UMA 150D 15/21 4 + UMA 150D 18/21 117.7 128.3 17.0 21.0 22.8 28.2 36 34 31.0 39.0 82.5 82.9 0.84 0.82 4 x 4.0 4 x 4.0 3/4 x 2.5 4) 3/4 x 2.5 4) 5b + UMA 150D 18/21 5 + UMA 150D 22/21 149.1 160.4 22.0 26.0 29.5 34.9 32 35 40.5 47.0 82.7 84.5 0.83 0.83 4 x 4.0 4 x 4.0 3/4 x 2.5 4) 3/4 x 2.5 4) 6b + UMA 150D 22/21 6 + UMA 150D 26/21 179.3 192.4 26.0 31.0 34.9 41.6 34 36 47.0 55.0 84.5 85.4 0.83 0.84 4 x 4.0 4 x 6.0 3/4 x 2.5 4) 3/4 x 4.0 4) 7 224.9 36.0 48.3 36 64.0 85.6 0.83 4 x 6.0 UPA 200 -- 11/ ... + .. + UMA 150D 30/21 8 + UMA 150D 37/22 9 256.9 42.0 56.3 47 76.0 85.1 0.83 3/4 x 4.0 4) 3/4 x 4.0 II 3) 3/4 x 4.0 4) 3) 3/4 x 4.0 4) + UMA 150D 37/22 287.0 44.0 59.0 43 78.0 84.9 0.84 3/4 x 4.0 II 10 + UMA 200D 45/21 322.4 52.0 69.7 31 89.0 85.7 0.87 4 x 10.0 1) 2) 3) 4) 3/4 x 6.0 4) Also see pages 3 and 55 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. Dimensions / Weights / Horizontal Installation 1) LP UPA 200 - 11/ .. 1) 2) 3) mm LA ¶ mm mA in ¶ kg Standard Special Standard Special D.o.l. Y-∆ Installation 2) A ¶ mm 1e 1d 1 515 515 515 1214 1214 1214 1214 1214 1214 67 67 68 70 70 71 192 192 192 195 195 195 v+h v+h v+h 645 645 645 2e 2c 2 580 580 580 1299 1299 1329 1299 1299 1329 73 73 76 77 77 80 192 192 192 195 195 195 v+h v+h v+h 720 720 735 3d 3 645 645 1474 1474 1474 1474 86 86 90 90 192 192 195 195 v+h v+h 840 840 4c 4 710 710 1584 1629 1584 1629 93 97 98 102 193 193 195 195 v+h v+h 927 950 5b 5 775 775 1694 1784 1694 1784 101 109 106 114 193 193 195 195 v+h v+h 1015 1060 6b 6 840 840 1849 1954 1849 1954 112 122 118 128 193 194 195 196 v+h v+h 1125 1177 7 905 2119 2119 134 140 194 196 v+h 1292 8 970 2264 2264 146 153 196 196 v 3) ---- 3) 9 1035 2329 2329 148 155 196 196 10 1110 2341 2341 207 215 196 199 Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. 58 Dmax in ¶ mm v v+h ---1506 60 Hz UPA 200 UPA 200 - 11 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 200 -- 11 /.. (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 3’’ / DN 80 The information is based on the model “with check valve / connection branch and threaded end”. The changes in the main dimensions of the “flanged end” model are specified in the table below. Check valve / connection branch with: Threaded end G 3’’ Flanged end DN 80 Length mm Length mm Outside dia. mm 200 200 (PN 10/16) 200 (PN 25/40) 200 200 Operating range: Qmin = 10 m3/h Qmax = End of characteristic curve Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. Optimum impeller dia. ”d” Maximum impeller dia. 59 60 Hz UPA 200 UPA 200 --14 for Well Diameters of 200 mm (8 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤+30 _C) H0 m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 5/21 5/21 7/21 25.1 30.2 35.5 5.0 6.0 7.5 6.7 8.0 10.1 43 41 40 11.4 12.9 15.6 75.2 75.5 77.3 0.77 0.81 0.81 4 x 2.5 4 x 2.5 4 x 2.5 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 2e + UMA 150D 9/21 2d + UMA 150D 9/21 2 + UMA 150D 13/21 50.4 60.4 72.1 10.0 11.2 14.5 13.4 15.0 19.4 36 31 36 19.8 21.5 27.5 78.5 78.1 81.7 0.83 0.85 0.82 4 x 2.5 4 x 2.5 4 x 2.5 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3d + UMA 150D 15/21 3 + UMA 150D 18/21 92.1 108.7 17.5 22.0 23.5 29.5 34 32 32.0 40.5 82.4 82.7 0.84 0.83 4 x 4.0 4 x 4.0 3/4 x 2.5 4) 3/4 x 2.5 4) 4c + UMA 150D 22/21 4 + UMA 150D 26/21 131.2 145.9 25.0 29.0 33.5 38.9 35 37 45.5 52.0 84.6 85.6 0.82 0.83 4 x 4.0 4 x 6.0 3/4 x 2.5 4) 3/4 x 4.0 4) 5c + UMA 150D 26/21 5 + UMA 150D 30/21 163.6 182.1 31.2 36.0 41.8 48.3 35 35 55.0 64.0 85.4 85.6 0.84 0.83 4 x 6.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 6c + UMA 150D 37/22 6 + UMA 150D 37/22 197.7 217.7 38.0 44.0 51.0 59.0 49 45 69.0 78.0 85.4 84.9 0.81 0.84 3/4 x 4.0 II 3) 3/4 x 4.0 II 3) 3/4 x 4.0 4) 3/4 x 4.0 4) 7c + UMA 150D 37/22 7 + UMA 200D 45/21 228.7 256.0 44.0 52.0 59.0 69.7 44 30 78.0 89.0 84.9 85.7 0.84 0.87 3/4 x 4.0 II 3) 4 x 10 3/4 x 4.0 4) 3/4 x 6.0 4) 8 + UMA 200D 55/21 294.1 60.0 80.5 32 101.0 86.8 0.86 4 x 16.0 3/4 x 6.0 4) 9 + UMA 200D 65/21 332.2 68.0 91.2 34 115.0 87.6 0.85 3/4 x 10 II 3) 3/4 x 10.0 4) UPA 200 -- 14/ ... + ... 1e + UMA 150D 1d + UMA 150D 1 + UMA 150D 1) 2) 3) 4) Also see pages 3 and 55 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. Dimensions / Weights / Horizontal Installation 1) LP mA in ¶ kg Installation 2) A Standard Special Standard Special D.o.l. Y-∆ 1e 1d 1 530 530 530 1229 1229 1249 1229 1229 1249 68 68 70 71 71 73 192 192 192 195 195 195 v+h v+h v+h 660 660 670 2e 2d 2 610 610 610 1359 1359 1439 1359 1359 1439 77 77 84 81 81 88 192 192 192 195 195 195 v+h v+h v+h 765 765 805 3d 3 690 690 1564 1609 1564 1609 92 96 96 100 193 193 195 195 v+h v+h 907 930 4c 4 770 770 1779 1884 1779 1884 108 117 113 123 193 194 195 196 v+h v+h 1055 1107 5c 5 850 850 1964 2064 1964 2064 125 134 130 139 194 194 196 196 v+h v+h 1187 1237 6c 6 930 930 2224 2224 2224 2224 144 144 150 150 196 196 196 196 v 3) v 3) ------- 7c 7 1020 1020 2314 2251 2314 2251 148 204 154 210 196 196 196 199 v 3) v+h ---1416 8 1100 2441 2441 228 235 199 199 v+h 1551 9 1180 2651 2651 252 259 199 199 v+h 1696 Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. 60 Dmax in ¶ mm mm UPA 200 -- 14/ .. 1) 2) 3) LA ¶ mm ¶ mm 60 Hz UPA 200 UPA 200 - 14 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 200 -- 14 /.. (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 3’’ / DN 80 The information is based on the model “with check valve / connection branch and threaded end. The changes in the main dimensions of the “flanged end” model are specified in the table below. Check valve / connection branch with Threaded end G 3’’ Flanged end DN 80 Length mm Length mm Outside dia. mm 200 200 (PN 10/16) 200 (PN 25/40) 200 200 Operating range: Qmin = 12 m3/h Qmax = End of characteristic curve Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. Maximum impeller dia. Optimum impeller dia. ”d” 61 60 Hz UPA 200B, 250C UPA 200B -- 80 for Well Diameters of 200 mm (8 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Discharge head Q = 0 m3/h UPA 200B -- 80/.. + ... Motor lead 2), flat Motor Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ 30 _C) H0 m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1g 1f 1d 1 + UMA 150D 7/21 + UMA 150D 9/21 + UMA 150D 13/21 + UMA 150D 13/21 29.1 34.1 36.8 39.1 9.0 10.5 12.5 14.0 12.1 14.1 16.8 18.8 33 34 39 37 18.0 20.5 24.5 26.5 76.7 78.4 82.0 81.8 0.84 0.84 0.79 0.81 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 2g 2f 2d 2 + UMA 150D + UMA 150D + UMA 150D + UMA 150D 15/21 18/21 22/21 26/21 55.7 64.0 69.2 76.2 17.0 21.0 25.0 28.0 22.8 28.2 33.5 37.5 35 34 36 38 31.0 39.0 45.5 51.0 82.5 82.9 84.6 85.7 0.84 0.82 0.82 0.82 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 4.0 4) 3f 3e 3c 3 + UMA 150D + UMA 150D + UMA 150D + UMA 150D 26/21 26/21 30/21 37/22 97.3 101.6 107.0 113.4 28.0 31.0 36.0 40.0 37.5 41.6 48.3 53.6 38 36 35 48 51.0 55.0 64.0 72.0 85.7 85.4 85.6 85.2 0.82 0.84 0.83 0.82 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0 II 3) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 4e + UMA 150D 37/22 4c + UMA 200D 45/21 4 + UMA 200D 55/21 135.8 143.6 152.9 42.0 50.0 54.0 56.3 67.1 72.4 46 32 35 76.0 86.0 93.0 85.1 85.7 86.7 0.83 0.86 0.85 3/4 x 4.0 II 3) 4 x 10.0 4 x 16.0 3/4 x 4.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 5d + UMA 200D 55/21 5 + UMA 200D 65/21 177.1 191.0 58.0 68.0 77.8 91.2 33 34 99.0 115.0 86.8 87.6 0.86 0.85 4 x 16.0 3/4 x 10.0 II 3) 3/4 x 6.0 4) 3/4 x 10.0 4) 6c + UMA 200D 65/21 6 + UMA 200D 75/21 215.9 228.5 74.0 80.0 99.2 107.3 31 31 124.0 136.0 87.6 87.5 0.86 0.85 3/4 x 10.0 II 3) 3/4 x 10.0 II 3) 3/4 x 10.0 4) 3/4 x 10.0 4) 7c + UMA 200D 90/21 7 + UMA 200D 90/21 253.8 267.4 90.0 95.0 120.7 127.4 34 32 156.0 162.0 88.2 88.2 0.83 0.84 3/4 x 16.0 II 3) 3/4 x 16.0 II 3) 3/4 x 16.0 4) 3/4 x 16.0 4) 8c + UMA 200D 90/21 8 + UMA 250D 110/21 288.4 309.4 100.0 110.0 134.1 147.5 30 33 169.0 188.0 88.2 88.7 0.85 0.83 3/4 x 16.0 II 3) 3/4 x 16.0 II 3) 3/4 x 16.0 4) 3/4 x 25.0 4) 1) 2) 3) 4) Also see pages 3 and 55 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. Dimensions / Weights / Horizontal Installation 1) LP LA ¶ mm mA in ¶ kg Dmax in ¶ mm Installation 2) A UPA 200B -- 80/.. mm Standard Special Standard Special D.o.l. Y-∆ 1g 1f 1d 1 582 582 582 582 1301 1331 1411 1411 1301 1331 1411 1411 89 92 99 99 95 98 105 105 193 193 193 193 196 196 196 196 v+h v+h v+h v+h 632 647 687 687 2g 2f 2d 2 714 714 714 714 1588 1633 1723 1828 1588 1633 1723 1828 113 117 125 134 122 126 134 143 194 194 194 195 196 196 196 198 v+h v+h v+h v+h 841 864 909 961 3f 3e 3c 3 846 846 846 846 1960 1960 2060 2140 1960 1960 2060 2140 145 146 155 162 155 156 165 172 195 195 195 198 198 198 198 198 v+h v+h v+h v 3) 1093 1093 1143 -- 4e 4c 4 978 978 978 2272 2209 2319 2272 2209 2319 172 225 245 184 237 257 198 201 205 198 201 201 v 3) v+h v+h -1284 1339 5d 5 1110 1110 2451 2581 2451 2581 256 279 269 292 205 201 201 205 v+h v+h 1471 1536 6c 6 1242 1242 2713 2803 2713 2803 289 305 304 320 201 205 205 205 v+h v+h 1668 1713 7c 7 1374 1374 3115 3115 3115 3115 348 348 364 364 211 211 211 211 v 3) 4) v 3) 4) --- 8c 8 1506 1506 3247 3035 3247 3035 358 428 446 446 211 232 211 235 v 3) 4) v 4) --- 1) 2) 3) 4) Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 62 ¶ mm 60 Hz UPA 200B, 250C UPA 200B -- 80 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 200B -- 80 /.. (Tolerances to ISO 9906 Class 2) Selection The characteristic curves shown apply to the standard impeller material, i.e. Noryl. The performance data for the full impeller diameter and impeller diameter “b” for the given number of stages will only be achieved when the impellers are made of Noryl (PPO). For the special impeller material (bronze), please select the next higher number of stages. In this case, please refer to the characteristic curves individually prepared for the quotation. The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Head losses in the check valve Hv : η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 5’’ / DN 125 The information is based on the model “with check valve / connection branch and threaded end”. Operating range: Qmin = 18 m3/h Qmax = End of characteristic curve The changes in the main dimensions of the “flanged end” model are specified in the table below. Check valve / connection branch with Threaded end G 5’’ Flanged end DN 125 Length mm Length mm Outside dia. mm 200 150 (PN 10/16) 150 (PN 25/40) 250 270 Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. Optimum dia.”f””d” optimaler impeller Laufrad-∅ Maximum Laufrad-∅ impeller dia. maximaler 63 60 Hz UPA 200B, 250C UPA 200B -- 130 for Well Diameters of 200 mm (8 inches) and Above Pumps with submersible motors for ... Pump unit Pump Discharge head Q = 0 m3/h UPA 200B -- 130/.. + ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Rated power Motor Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Motor lead 2), flat Number x cross-section of conductors (use under water, 460 V and ≤+30 _C) H0 m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1g 1e 1c 1 + UMA 150D 7/21 + UMA 150D 9/21 + UMA 150D 13/21 + UMA 150D 13/21 24.6 28.8 33.2 35.6 9.0 11.2 13.5 15.5 12.1 15.0 18.1 20.8 33 32 38 34 18.0 21.5 26.0 29.0 76.7 78.1 81.9 81.4 0.84 0.85 0.81 0.83 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 2g 2e 2d 2c 2 + UMA 150D + UMA 150D + UMA 150D + UMA 150D + UMA 150D 15/21 18/21 22/21 22/21 26/21 48.4 56.8 61.4 64.6 70.1 18.0 22.0 25.0 26.0 30.0 24.1 29.5 33.5 34.9 40.2 34 31 36 34 37 33.0 40.5 45.5 47.0 54.0 82.2 82.7 84.6 84.5 85.5 0.84 0.83 0.82 0.83 0.83 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 4.0 4) 3e 3d 3c 3 + UMA 150D + UMA 150D + UMA 150D + UMA 150D 30/21 30/21 37/22 37/22 85.3 91.1 96.6 103.8 33.0 36.0 40.0 44.0 44.3 48.3 53.6 59.0 38 36 49 45 60.0 64.0 72.0 78.0 85.8 85.6 85.2 84.9 0.81 0.83 0.82 0.84 4 x 6.0 4 x 6.0 3/4 x 4.0 II 3) 3/4 x 4.0 II 3) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 4d 4c 4b 4 + UMA 200D + UMA 200D + UMA 200D + UMA 200D 45/21 45/21 55/21 55/21 122.2 128.8 135.3 140.1 48.0 52.0 56.0 60.0 64.4 69.7 75.1 80.5 33 30 34 33 83.0 89.0 96.0 101.0 85.7 85.7 86.8 86.8 0.86 0.87 0.85 0.86 4 x 10 4 x 10 4 x 16 4 x 16 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 5c + UMA 200D 65/21 5b + UMA 200D 65/21 5 + UMA 200D 65/21 162.7 169.1 175.1 66.0 68.0 74.0 88.5 91.2 99.2 35 33 31 112.0 115.0 124.0 87.5 87.6 87.6 0.85 0.85 0.86 3/4 x 10 II 3) 3/4 x 10 II 3) 3/4 x 10 II 3) 3/4 x 10 4) 3/4 x 10 4) 3/4 x 10 4) 6c + UMA 200D 75/21 6b + UMA 200D 90/21 6 + UMA 200D 90/21 194.7 204.0 211.5 78.0 85.0 90.0 104.6 114.0 120.7 31 35 33 134.0 149.0 156.0 87.5 88.1 88.2 0.84 0.82 0.83 3/4 x 10 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 10 4) 3/4 x 16 4) 3/4 x 16 4) 7c + UMA 200D 90/21 7b + UMA 200D 90/21 7 + UMA 250D 110/21 227.8 236.6 249.5 95.0 95.0 105.0 127.4 127.4 140.8 32 31 33 162.0 162.0 181.0 88.2 88.2 88.6 0.84 0.84 0.83 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 16 4) 3/4 x 16 4) 3/4 x 25 4) 8b + UMA 250D 110/21 273.8 115.0 154.2 32 195.0 88.7 0.84 3/4 x 16 II 3) 3/4 x 25 4) 1) 2) 3) 4) Also see pages 3 and 55 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. Dimensions / Weights / Horizontal Installation 1) LP LA ¶ mm mA in ¶ kg Dmax in ¶ mm Installation 2) A UPA 200B -- 130/.. mm Standard Special Standard Special D.o.l. Y-∆ 1g 1e 1c 1 545 595 595 595 1264 1344 1424 1424 1264 1344 1424 1424 89 92 99 99 99 99 106 106 193 193 193 193 196 196 196 196 v+h v+h v+h v+h 585 650 690 690 2g 2e 2d 2c 2 740 740 740 740 740 1614 1659 1749 1749 1854 1614 1659 1749 1749 1854 113 117 125 125 135 122 126 134 135 144 194 194 194 194 195 196 196 196 196 198 v+h v+h v+h v+h v+h 857 880 925 925 977 3e 3d 3c 3 885 885 885 885 2099 2099 2179 2179 2099 2099 2179 2179 155 155 162 162 165 165 172 172 195 195 198 198 198 198 198 198 v+h v+h v 3) v 3) 1172 1172 --- 4d 4c 4b 4 1030 1030 1030 1030 2261 2261 2371 2371 2261 2261 2371 2371 225 225 245 245 237 237 257 257 201 201 205 205 201 201 201 201 v+h v+h v+h v+h 1326 1326 1381 1381 5c 5b 5 1175 1175 1175 2646 2646 2646 2646 2646 2646 279 279 279 292 292 292 201 201 201 205 205 205 v+h v+h v+h 1591 1591 1591 6c 6b 6 1320 1320 1320 2881 3061 3061 2881 3061 3061 305 337 337 320 352 352 205 211 211 205 211 211 v+h v 3) 4) v 3) 4) 1781 --- 7c 7b 7 1465 1465 1465 3206 3206 2994 3206 3206 2994 348 348 418 364 364 434 211 211 232 211 211 235 v 3) 4) v 3) 4) v+h --1910 8b 1610 3139 3139 428 446 232 235 v 4) ---- 1) 2) 3) 4) Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 64 ¶ mm 60 Hz UPA 200B, 250C UPA 200B -- 130 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 200B -- 130 /.. (Tolerances to ISO 9906 Class 2) Selection The characteristic curves shown apply to the standard impeller material, i.e. Noryl. The performance data for the full impeller diameter for the given number of stages will only be achieved when the impellers are made of Noryl (PPO). For the special impeller material (bronze), please select the next higher number of stages. In this case, please refer to the characteristic curves individually prepared for the quotation. The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 5’’ / DN 125 The information is based on the model “with check valve / connection branch and threaded end”. The changes in the main dimensions of the “flanged end” model are specified in the table below. Operating range: Qmin = 24 m3/h Qmax = End of characteristic curve Check valve / connection branch with: Threaded end G5’’ Flanged end DN 125 Length mm Length mm Outside dia. mm 200 150 (PN 10/16) 150 (PN 25/40) 250 270 Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. Optimum impeller dia. ”d” Maximum impeller dia. 65 60 Hz UPA 200B, 250C UPA 250C -- 120 for Well Diameters of 250 mm (10 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump UPA 250C -- 120/.. + ... Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) Ho m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1l 1h 1f 1d 1 + UMA 150D + UMA 150D + UMA 150D + UMA 150D + UMA 150D 13/21 18/21 18/21 22/21 26/21 42.5 50.2 53.7 58.8 62.5 15.5 20.0 22.0 25.0 29.0 20.8 26.8 29.5 33.5 38.9 34 35 32 36 38 29.0 37.0 40.5 45.5 52.0 81.4 83.1 82.7 84.6 85.6 0.83 0.82 0.83 0.82 0.83 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 4.0 4) 2l 2k 2h 2f 2d 2 + UMA 150D + UMA 150D + UMA 150D + UMA 150D + UMA 200D + UMA 200D 26/21 30/21 37/22 37/22 45/21 55/21 82.6 90.4 97.6 104.3 114.6 122.3 31.2 36.0 42.0 44.0 52.0 60.0 41.8 48.3 56.3 59.0 69.7 80.5 35 35 47 44 31 32 55.0 64.0 76.0 78.0 89.0 101.0 85.4 85.6 85.1 84.9 85.7 86.8 0.84 0.83 0.83 0.84 0.87 0.86 4 x 6.0 4 x 6.0 3/4 x 4.0 II 3) 3/4 x 4.0 II 3) 4 x 10.0 4 x 16 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 3h 3f 3d 3 + UMA 200D + UMA 200D + UMA 200D + UMA 200D 55/21 65/21 65/21 90/21 144.5 156.3 169.1 181.0 62.0 68.0 76.0 90.0 83.1 91.2 101.9 120.7 31 33 30 33 105.0 115.0 126.0 156.0 86.8 87.6 87.6 88.2 0.86 0.85 0.87 0.83 4 x 16 3/4 x 10 II 3) 3/4 x 10 II 3) 3/4 x 16 II 3) 3/4 x 6.0 4) 3/4 x 10 4) 3/4 x 10 4) 3/4 x 16 4) 4f + UMA 200D 90/21 4d + UMA 250D 110/21 4 + UMA 250D 132/21 208.7 229.9 243.8 95.0 105.0 120.0 127.4 140.8 160.9 32 34 35 162.0 181.0 200.0 88.2 88.6 89.3 0.84 0.83 0.85 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 25 II 3) 3/4 x 16 4) 3/4 x 25 4) 3/4 x 25 4) 5d + UMA 250D 132/21 5 + UMA 250D 160/21 286.0 304.0 130.0 150.0 174.3 201.2 33 32 214.0 247.0 89.3 89.7 0.86 0.85 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 25 4) 3/4 x 35 4) 5) 6 366.3 180.0 241.4 32 304.0 90.2 0.83 3/4 x 35 II 3) 5) + UMA 250D 190/21 7 1) 2) 3) 4) 5) 6) 7) + UMA 300D 250/22 434.6 215.0 288.3 62 359.0 89.6 0.84 3/3x70 II + 1x35 3) 6) 3/4 x 35 4) 5) 6x95 + 1x50 4) 7) Also see pages 3 and 55 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. 1 x 3--core flat + 1 x 4--core round. 2 x 3--core flat + 1 x 1--core round. 6 x 1--core round + 1 x 1--core round. Dimensions / Weights / Horizontal Installation 1) LP LA ¶ mm mA in ¶ kg Dmax in ¶ mm Installation 2) A UPA 250C -- 120/.. mm Standard Special Standard Special D.o.l. Y-∆ 1l 1h 1f 1d 1 681 681 681 681 681 1510 1600 1600 1690 1795 1510 1600 1600 1690 1795 123 131 131 139 148 135 143 143 151 160 230 230 230 230 232 232 232 232 232 233 v+h v+h v+h v+h v+h 751 796 796 841 893 2l 2k 2h 2f 2d 2 828 828 828 828 828 828 1942 2042 2122 2122 2059 2169 1942 2042 2122 2122 2059 2169 169 178 185 185 238 258 185 194 201 201 254 274 232 232 233 233 235 238 233 233 233 233 235 235 v+h v+h v 3) v 3) v+h v+h 1040 1090 --1099 1154 3h 3f 3d 3 975 975 975 975 2316 2446 2446 2716 2316 2446 2446 2716 278 301 301 349 299 322 322 370 238 235 235 244 235 239 239 244 v+h v+h v+h v 3) 1301 1366 1366 -- 4f 4d 4 1122 1122 1122 2863 2651 2781 2863 2651 2781 369 439 483 394 464 508 244 246 257 244 257 257 v 3) v+h v+h -1542 1607 5d 5 1269 1269 2928 3038 2928 3038 503 540 532 569 257 257 257 266 v+h v 4) 1754 -- 6 1416 3335 3335 611 644 266 280 v 3) 4) -- 7 1563 3636 3636 757 794 304 304 v 4) -- 1) 2) 3) 4) Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 66 ¶ mm 60 Hz UPA 200B, 250C UPA 250C -- 120 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 250C -- 120 /.. (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 6’’ / DN 150 The information is based on the model “with check valve / connection branch and threaded end”. The changes in the main dimensions of the “flanged end” model are specified in the table below. Check valve / connection branch with: Threaded end G6’’ Flanged end DN 150 Length mm Length mm Outside dia. mm 229 179 (PN 10/16) 179 (PN 25/40) 285 300 Threaded end to DIN ISO 228, Part 1. Operating range: Qmin = 24 m3/h Qmax = End of characteristic curve Flange mating dimensions to DIN EN 1092--2. Optimum impeller dia. ”f” Maximum impeller dia. 250 400 67 60 Hz UPA 200B, 250C UPA 250C --150 for Well Diameters of 250 mm (10 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Discharge head Q = 0 m3/h UPA 250C -- 150/.. + ... Motor lead 2), flat Motor Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) H0 m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1l 1k 1d 1 + UMA 150D + UMA 150D + UMA 150D + UMA 150D 18/21 22/21 30/21 37/22 39.1 46.3 55.9 59.6 19.0 24.0 33.0 38.0 25.5 32.2 44.3 51.0 36 37 38 49 36.0 44.0 60.0 69.0 83.2 84.7 85.8 85.4 0.81 0.81 0.81 0.81 4 x 4.0 4 x 4.0 4 x 6.0 3/4 x 4.0 II 3) 3/4 x 2.5 4) 3/4 x 2.5 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 2k 2h 2f 2c 2 + UMA 200D + UMA 200D + UMA 200D + UMA 200D + UMA 200D 45/21 55/21 55/21 65/21 65/21 92.5 99.2 106.8 113.8 117.7 48.0 54.0 60.0 68.0 76.0 64.4 72.4 80.5 91.2 101.9 32 35 32 34 30 83.0 93.0 101.0 115.0 126.0 85.7 86.7 86.8 87.6 87.6 0.86 0.85 0.86 0.85 0.87 4 x 10 4 x 16 4 x 16 3/4 x 10 II 3) 3/4 x 10 II 3) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 10 4) 3/4 x 10 4) 3h 3g 3d 3b 3 + UMA 200D + UMA 200D + UMA 200D + UMA 250D + UMA 250D 75/21 90/21 90/21 110/21 110/21 143.2 151.4 162.6 172.1 176.5 80.0 90.0 100.0 110.0 120.0 107.3 120.7 134.1 147.5 160.9 31 34 31 33 31 136.0 156.0 169.0 188.0 203.0 87.5 88.2 88.2 88.7 88.7 0.85 0.83 0.85 0.83 0.84 3/4 x 10 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 10 4) 3/4 x 16 4) 3/4 x 16 4) 3/4 x 25 4) 3/4 x 25 4) 4e 4c 4b 4 + UMA 250D 132/21 + UMA 250D 132/21 + UMA 250D 160/21 + UMA 250D 160/21 213.0 221.9 229.3 235.1 125.0 135.0 145.0 155.0 167.6 181.0 194.4 207.9 34 32 33 31 207.0 222.0 241.0 254.0 89.3 89.3 89.7 89.6 0.85 0.86 0.85 0.86 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 25 4) 3/4 x 25 4) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 5d + UMA 250D 190/21 5b + UMA 250D 190/21 5 + UMA 300D 250/22 276.2 287.2 300.9 170.0 180.0 200.0 228.0 241.4 268.2 34 32 62 291.0 304.0 341.0 90.2 90.2 89.3 0.82 0.83 0.83 3/4 x 35 II 3) 5) 3/4 x 35 II 3) 5) 3/3x70 II + 1x35 3) 6) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 6x95 + 1x50 5) 7) 6b + UMA 300D 250/22 350.5 225.0 301.7 61 373.0 89.8 0.85 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 5) 7) 1) 2) 3) 4) 5) 6) 7) Also see pages 3 and 55 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. 1 x 3--core flat + 1 x 4--core round. 2 x 3--core flat + 1 x 1--core round. 6 x 1--core round + 1 x 1--core round. Dimensions / Weights / Horizontal Installation 1) LP LA ¶ mm mA in ¶ kg Dmax in ¶ mm Installation 2) A UPA 250C -- 150/.. mm Standard Special Standard Special D.o.l. Y-∆ 1l 1k 1d 1 690 690 690 690 1609 1699 1904 1984 1609 1699 1904 1984 129 137 156 163 141 149 168 175 230 230 232 233 232 232 233 233 v+h v+h v+h v 3) 800 845 947 -- 2k 2h 2f 2c 2 846 846 846 846 846 2077 2187 2187 2317 2317 2077 2187 2187 2317 2317 235 255 255 278 278 250 270 270 293 293 235 238 238 235 235 235 238 235 239 239 v+h v+h v+h v+h v+h 1112 1167 1167 1232 1232 3h 3g 3d 3b 3 1002 1002 1002 1002 1002 2563 2743 2743 2531 2531 2563 2743 2743 2531 2531 313 345 345 415 415 331 363 363 433 433 239 244 244 246 246 239 244 244 257 257 v+h v 3) v 3) v+h v+h 1433 --1417 1417 4e 4c 4b 4 1158 1158 1158 1158 2817 2817 2927 2927 2817 2817 2927 2927 478 478 515 515 499 499 536 536 257 257 257 257 257 257 266 266 v+h v+h v+h v+h 1638 1638 1693 1693 5d 5b 5 1314 1314 1314 3233 3233 3387 3233 3233 3387 584 584 709 609 609 734 266 266 304 280 280 304 v 3) 4) v 3) 4) v 4) ---- 6b 1470 3543 3543 728 757 304 304 v 4) -- 1) 2) 3) 4) Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 68 ¶ mm 60 Hz UPA 200B, 250C UPA 250C -- 150 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 250C -- 150 /.. (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 6’’ / DN 150 The information is based on the model “with check valve / connection branch and threaded end”. The changes in the main dimensions of the “flanged end” model are specified in the table below. Check valve / connection branch with: Threaded end G 6’’ Flanged end DN 150 Length mm Length mm Outside dia. mm 229 179 (PN 10/16) 179 (PN 25/40) 285 300 Threaded end to DIN ISO 228, Part 1. Operating range: Qmin = 36 m3/h Qmax = End of characteristic curve Flange mating dimensions to DIN EN 1092--2. Optimum impeller dia. ”g” Maximum impeller dia. 250 400 69 60 Hz UPA 200B, 250C UPA 250C -- 250 for Well Diameters of 250 mm (10 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Discharge head Q = 0 m3/h UPA 250C -- 250/.. + ... Motor lead 2), flat Motor Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) H0 m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1m 1k 1f 1 + UMA 150D + UMA 150D + UMA 150D + UMA 150D 26/21 26/21 30/21 37/22 37.8 42.1 47.0 54.7 29.0 31.2 36.0 44.0 38.9 41.8 48.3 59.0 37 35 35 44 52.0 55.0 64.0 78.0 85.6 85.4 85.6 84.9 0.83 0.84 0.83 0.84 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0 II 3) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 2m 2l 2g 2e 2c 2 + UMA 200D + UMA 200D + UMA 200D + UMA 200D + UMA 200D + UMA 200D 55/21 55/21 65/21 65/21 90/21 90/21 73.7 80.3 89.0 96.1 104.2 108.0 58.0 62.0 70.0 76.0 85.0 90.0 77.8 83.1 93.9 101.9 114.0 120.7 33 31 33 31 34 33 99.0 105.0 118.0 126.0 149.0 156.0 86.8 86.8 87.6 87.6 88.1 88.2 0.86 0.86 0.86 0.87 0.82 0.83 4 x 16 4 x 16 3/4 x 10 II 3) 3/4 x 10 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 10 4) 3/4 x 10 4) 3/4 x 16 4) 3/4 x 16 4) 3h 3f 3d 3 + UMA 200D 90/21 + UMA 250D 110/21 + UMA 250D 132/21 + UMA 250D 132/21 125.8 136.5 149.8 159.0 100.0 110.0 120.0 135.0 134.1 147.5 160.9 181.0 31 33 35 32 169.0 188.0 200.0 222.0 88.2 88.7 89.3 89.3 0.85 0.83 0.85 0.86 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 16 4) 3/4 x 25 4) 3/4 x 25 4) 3/4 x 25 4) 4f 4e 4c 4 + UMA 250D 160/21 + UMA 250D 160/21 + UMA 250D 190/21 + UMA 250D 190/21 181.9 190.4 205.9 213.4 145.0 150.0 170.0 180.0 194.4 201.2 228.0 241.4 34 32 34 32 241.0 247.0 291.0 304.0 89.7 89.7 90.2 90.2 0.85 0.85 0.82 0.83 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 35 II 3) 5) 3/4 x 35 II 3) 5) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 5e + UMA 250D 190/21 5b + UMA 300D 250/22 238.5 264.4 190.0 220.0 254.8 295.0 31 62 317.0 367.0 90.2 89.7 0.84 0.84 3/4 x 35 II 3) 5) 3/3x70 II + 1x35 3) 6) 3/4 x 35 4) 5) 6x95 + 1x50 4) 7) 1) 2) 3) 4) 5) 6) 7) Also see pages 3 and 55 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. 1 x 3--core flat + 1 x 4--core round. 2 x 3--core flat + 1 x 1--core round. 6 x 1--core round + 1 x 1--core round. Dimensions / Weights / Horizontal Installation 1) LP mA in ¶ kg Installation 2) A Standard Special Standard Special D.o.l. Y-∆ 1m 1k 1f 1 709 709 709 709 1823 1823 1923 2003 1823 1823 1923 2003 146 147 156 163 154 155 164 171 232 232 232 233 233 233 233 233 v+h v+h v+h v 3) 896 896 946 -- 2m 2l 2g 2e 2c 2 884 884 884 884 884 884 2225 2225 2355 2355 2625 2625 2225 2225 2355 2355 2625 2625 255 255 278 278 326 326 266 266 289 289 337 337 238 238 235 235 244 244 235 235 239 239 244 244 v+h v+h v+h v+h v 3) v 3) 1185 1185 1250 1250 --- 3h 3f 3d 3 1059 1059 1059 1059 2800 2588 2718 2718 2800 2588 2718 2718 345 415 459 459 359 429 473 473 244 246 257 257 244 257 257 257 v 3) v+h v+h v+h -1454 1519 1519 4f 4e 4c 4 1234 1234 1234 1234 3003 3003 3153 3153 3003 3003 3153 3153 515 515 566 566 533 533 584 584 257 257 266 266 266 266 280 280 v 4) v 4) v 3) 4) v 3) 4) ----- 5e 5b 1409 1409 3328 3482 3328 3482 585 710 606 731 266 304 280 304 v 3) 4) v 4) --- Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 70 Dmax in ¶ mm mm UPA 250C- 250/.. 1) 2) 3) 4) LA ¶ mm ¶ mm 60 Hz UPA 200B, 250C UPA 250C -- 250 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 250C -- 250 /.. (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 6’’ / DN 150 The information is based on the model “with check valve / connection branch and threaded end”. The changes in the main dimensions of the “flanged end” model are specified in the table below. Check valve / connection branch with: Threaded end G 6’’ Flanged end DN 150 Length mm Length mm Outside dia. mm 229 179 (PN 10/16) 179 (PN 25/40) 285 300 Threaded end to DIN ISO 228, Part 1. Operating range: Qmin = 60 m3/h Qmax = End of characteristic curve Flange mating dimensions to DIN EN 1092--2. Optimum impeller dia. ”h” Maximum impeller dia. 250 400 71 60 Hz 72 UPA 200B, 250C UPA 300, 350 60 Hz Application Submersible Borehole Pumps Handling clean or slightly contaminated water in applications such as: -- general water supply -- irrigation and spray irrigation -- pressure boosting -- lowering and maintaining ground water levels as well as -- drainage for Well Diameters of 300 mm (12 inches) and Above and of 350 mm (14 inches) and Above Single-entry and mixed flow Also used in mining, sprinkler installations, fountains etc. Permissible sand content in the fluid handled: 50 g/m3. Also suitable for aggressive seawater if supplied in material variant C3 (duplex). Operating Data Capacity . . . . . . . . . . . . . . . . . . . Q up to 1080 m3/h (300 l/s or up to 4000 US GPM) Head . . . . . . . . . . . . . . . . . . . . . . H up to 474 m Temperature of fluid handled . . t up to +50 °C Speed . . . . . . . . . . . . . . . . . . . . . n ≈ 3500 rpm Design Single or multistage, single-entry centrifugal pump in ring-section design. For vertical and horizontal installation. Mixed flow hydraulic systems with impellers that can be turned down. Stage casings are connected by means of stud bolts. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Both models with threaded or flanged end. Particularly suitable for vertical installation in narrow deep wells. Designation (Example) UPA 300 -- 94 / 5 b Available automation products: Type series Minimum well diameter (mm) • Hyamaster (for UPA 300) (for ex.: 300 mm = 12 inches) Capacity Qopt at 50 Hz (l/s) Number of stages Reduced impeller diameter(s) Certification Quality management certified to ISO 9001 Product Features --------- Very sturdy design Suitable for installation in narrow deep wells High efficiency Motor designed for maximum pump output Low noise level For vertical or horizontal installation Non-return valve protected against blocking Pre-filled motor; no risk of contamination of the handled water 73 UPA 300, 350 60 Hz Selection Chart (Ranges on Offer) n ≈ 3500 rpm UPA 300 -- 94 UPA 300 -- 65 UPA 350 -- 128 UPA 350 -- 180 UPA 300 -- 65 UPA 350 -- 180 UPA 300 -- 94 UPA 350 -- 128 Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this range. The operating ranges ∆QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages. 74 UPA 300, 350 60 Hz Material Variants Type of Installation G (Standard) B (Special) C3 (Duplex) Cast iron (JL 1030 5) ) / Nodular cast iron 1) (JS--1030 6) ) Bronze (CC480K--GS) / Aluminium bronze 1) (CC333G--GS) CrNiMo steel (1.4517) Pump Casing Impeller Shaft Wear ring Bearings Screws, bolts and nuts 2) Bronze (CC480K--GS) Cr steel (1.4021) CrNiMo steel (1.4517) CrNiMo steel (1.4462) high-performance plastics Cr steel (1.4021) / carbon CrNiMo steel (1.4462) CrNiMo steel (1.4138) Drive Type . . . . . . . . . . . . . . . . water-filled submersible squirrel-cage motor, 2-poles Type of enclosure . . . . IP 68 Frequency . . . . . . . . . . . 60 Hz Type of current . . . . . . . three-phase (3~) Rated voltage U . . . . . . 440 V ... 460 V Rated power PN . . . . . . up to 415 kW (556.5 hp) Aluminium bronze (CC308G--R750) / carbon CrNiMo steel (A4--70) In general, the pumps are installed vertically. Some models may also be installed horizontally, depending on the number of stages and motor size. SiC / SiC CrNiMo steel (1.4462) Frequency of starts . . . 10 / h 1) and 5 / h 2) Minimum delay before re-starting . . . . . 3 min Motor design is in compliance with VDE regulations. 1) 2) G (Standard) C2 (Special) C3 (Duplex) motor Shaft UMA 200D and 250D motors UMA 300D motor and larger motors Connection to Power Supply CrNiMo steel (1.4462) Casing Cast iron (JL-1030 5) / JL 1040 4) 7) ) CrNiMo steel (1.4408 3) / 1.4517 4) ) CrNiMo steel (1.4539 3) / (1.4517 4) ) The submersible motors are supplied ex factory with 1 or 2 motor leads, each equipped with an earth conductor. All motors are provided with internal earthing. Stator case CrNi steel (1 4301) (1.4301) CrNiMo steel (1 4571 3) / (1.4571 1.4462 4) ) CrNiMo steel (1 4539 3) / (1.4539 1.4462 4) ) Any extension cables required are connected using water-tight cable connectors. Screws, bolts and nuts 2) CrNiMo steel (1.4539 3) / 1.4462 4) ) CrNiMo steel (A4-70) 1) For large number of stages 2) In contact with fluid handled 3) for motors UMA 200D and. UMA 4) for motors UMA 300D only 250D only 5) 6) 7) DIN mat. code: GG-20 DIN mat. code: GGG-40 DIN mat. code: GG-25 Bearings / Lubrication Radial plain bearings: pump bearings lubricated by the fluid handled, motor bearings by the motor’s water fill. Depending on the pump size and number of stages, 1 or 2 intermediate bearings are fitted in the pump. Axial thrust is balanced by a tilting-pad thrust bearing in the motor (lower end). Direction of Rotation of the Pump Clockwise rotation (when looking at the drive shaft end). Pump End (Discharge Nozzle) Optionally with internal thread G 6’’ and G 8’’ or flange DN 150 to DN 250, depending on pump size. Coating (Standard) Quality . . . . . . . . . . . . . . 2-component high-build coating (epoxy resin base), approved for drinking water contact Coating structure . . . . . Primer and top coat Film thickness . . . . . . . 100 to 150 µm Colour . . . . . . . . . . . . . . ultramarine blue (RAL 5002) Motor leads and extension cables are suitable for drinking water applications. Starting Methods D.o.l. (autotransformer or soft starter) or star-delta. Speed Control / Variable Speed The submersible borehole pumps can also be run at variable speed to accommodate different operating points. Application Temperatures The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = +30 °C. An indispensable requirement for this is a flow velocity of v ≥0.5 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = +50 °C or for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.). Variants Available on Request ----- Other materials More wear-resistant designs Higher supply voltages up to U = 6600 V Models with cooling, suction or pressure shroud 75 60 Hz UPA 300, 350 Design Features (UPA 300--94/.. + UMA 250D ../21) Check valve with anti-blockage valve disc -- No jamming or tilting. -- Spring-loaded design makes for minimum valve closing times and prevents waterhammer. -- High operating reliability. All wetted plastic components are approved for drinking water contact (BAM 1)) -- Coating, electric cables, seal elements, gaskets, etc. are absolutely fit for use in drinking water applications. 1) German Federal Institute for Materials Research Robust wear rings -- Replaceable wear rings made of corrosion- and wear-resistant metal. -- Protection against wear in the clearance; easy servicing. Enclosed pump bearing -- No-maintenance design, high wear resistance. -- For trouble-free long-term operation. Stainless steel union elements -- All wetted bolts, screws and nuts are made of CrNiMo steel. -- High operating reliability. -- Easy to remove and re-use even after many years of operation. Mixed-flow impellers -- Can be turned down. This means pump performance can be exactly matched to head requirements in the system. Stainless steel pump shaft -- Fully protected by impeller hubs and sleeves from direct wear caused by the fluid handled. Wear-resistant mechanical seal -- Long service life and high operating reliability. The KSB motor -- Efficiencies up to 91 %. -- VDE-compliant, i.e. high level of electrical safety. -- Designed for max. pump power to protect unit from overloads. Counter thrust bearing -- Reliable balancing of negative axial thrust. -- Impellers do not rub on the stage casings. Dynamically balanced rotor -- Ensures smooth running. Tried and tested thrust bearing -- Water-lubricated self-aligning tilting-pad journal bearing. -- No-maintenance design suitable for maximum load-carrying capacity under continuous operation conditions. -- New materials combination (stainless steel / carbon) for high safety factor. Reliable pressure balancing system -- Optimum rubber expansion diaphragm design. -- Enables installation at very low depths 3411:10 76 60 Hz UPA 300, 350 77 UPA 300, 350 60 Hz UPA 300 -- 65 for Well Diameters of 300 mm (12 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump Discharge head Q=0 UPA 300 -- 65/ ... + ... Motor lead 2), flat Motor Rated power m3/h Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ 30 _C) Ho m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1n 1m 1l 1f 1 + UMA 200D + UMA 200D + UMA 200D + UMA 200D + UMA 200D 37/21 37/21 37/21 45/21 55/21 42.1 49.9 54.5 59.6 69.0 26.0 34.0 38.0 46.0 60.0 34.9 45.6 51.0 61.7 80.5 41 38 35 34 32 49.5 61.0 67.0 80.0 101.0 83.5 84.6 84.8 85.7 86.8 0.79 0.84 0.85 0.85 0.86 4 x 10 4 x 10 4 x 10 4 x 10 4 x 16 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 2m 2l 2g 2d 2 + UMA 200D 65/21 + UMA 200D 75/21 + UMA 200D 90/21 + UMA 250D 110/21 + UMA 250D 132/21 101.5 111.4 120.4 132.9 142.9 68.0 78.0 95.0 110.0 125.0 91.2 104.6 127.4 147.5 167.6 34 31 32 33 34 115.0 134.0 162.0 188.0 207.0 87.6 87.5 88.2 88.7 89.3 0.85 0.84 0.84 0.83 0.85 3/4 x 10 II 3) 3/4 x 10 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 25 II 3) 3/4 x 10 4) 3/4 x 10 4) 3/4 x 16 4) 3/4 x 25 4) 3/4 x 25 4) 3k 3h 3e 3d 3 + UMA 250D 132/21 + UMA 250D 160/21 + UMA 250D 160/21 + UMA 250D 190/21 + UMA 300D 250/22 171.4 179.9 189.2 199.9 218.8 130.0 145.0 155.0 170.0 200.0 174.3 194.4 207.9 228.0 268.2 33 34 32 34 63 214.0 241.0 254.0 291.0 341.0 89.3 89.7 89.6 90.2 89.3 0.86 0.85 0.86 0.82 0.83 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 35 II 3) 5) 3/3x70 II + 1x35 3) 6) 3/4 x 25 4) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 6x95 + 1x50 4) 7) 4g 4e 4b 4 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 248.3 258.0 276.7 289.9 200.0 215.0 240.0 265.0 268.2 288.3 321.8 355.4 63 62 61 59 341.0 359.0 394.0 429.0 89.3 89.6 90.0 90.2 0.83 0.84 0.85 0.86 3/3x70 II + 1x35 3)6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 5e + UMA 300D 250/22 5b + UMA 300D 250/22 5 + UMA 300D 300/22 320.9 344.0 362.4 265.0 295.0 330.0 355.4 395.6 442.5 59 57 59 429.0 471.0 534.0 90.2 90.4 90.8 0.86 0.87 0.86 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6c + UMA 300D 300/22 6 + UMA 300D 400/22 408.4 432.9 345.0 390.0 462.7 523.0 58 57 554.0 622.0 90.9 91.1 0.86 0.87 6x95 II + 1x50 3) 7) 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 7c + UMA 300D 400/22 474.6 400.0 536.4 56 634.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 1) 2) 3) 4) 5) 6) 7) Also see pages 3 and 75 3/4 = 1 x 3-core + 1 x 4-core. flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. 1 x 3--core flat + 1 x 4--core round. 2 x 3--core flat + 1 x 1--core round. 6 x 1--core round + 1 x 1--core round. Dimensions / Weights / Horizontal Installation 1) LP LA ¶ mm mA in ¶ kg Dmax ¶ mm Installation 2) A UPA 300 - 65/ .. ¶ mm Standard Special Standard Special D.o.l Y-∆ 1n 1m 1l 1f 1 735 735 735 735 735 1876 1876 1876 1966 2076 1876 1876 1876 1966 2076 213 213 213 229 249 224 224 224 240 260 269 269 269 269 271 276 276 276 276 276 v+h v+h v+h v+h v+h 946 946 946 991 1046 2m 2l 2g 2d 2 900 900 900 930 930 2371 2461 2641 2459 2589 2371 2461 2641 2459 2589 304 320 352 430 474 319 335 367 446 490 276 275 278 278 289 275 275 278 289 289 v+h v+h v 3) v+h v+h 1276 1321 -1335 1400 3k 3h 3e 3d 3 1095 1095 1095 1095 1095 2754 2864 2864 3014 3168 2754 2864 2864 3014 3168 506 543 543 594 747 526 563 563 614 770 289 289 289 298 325 289 298 298 311 325 v+h v+h v+h v 3) 4) v 4) 1565 1620 1620 --- 4g 4e 4b 4 1260 1260 1260 1260 3333 3333 3333 3333 3333 3333 3333 3333 779 779 779 779 806 806 806 806 325 325 325 325 325 325 325 325 v 4) v 4) v 4) v 4) ----- 5e 5b 5 1425 1425 1425 3498 3498 3678 3498 3498 3678 811 811 889 842 842 920 325 325 304 325 325 304 v 4) v 4) v 4) ---- 6c 6 1590 1590 3843 3963 3843 3963 921 973 956 1008 304 304 304 304 v 4) v 3) 4) --- 7c 1755 4128 4128 1005 1044 304 304 v 3) 4) -- 1) 2) 3) 4) Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 78 ¶ mm 60 Hz UPA 300, 350 UPA 300 -- 65 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 300 -- 65 (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 6’’ / DN 150 The information is based on the model “with check valve and threaded end”. The changes in the main dimensions of the “flanged end” model or the model “with connection branch” are specified in the table below. a) Check valve with: Threaded end G 6’’ Flanged end DN 150 Length mm Length mm Outside dia. mm 255 220 (PN 10/16) 228 (PN 25/40) 285 300 b) Connection branch with: Threaded end G 6’’ Operating range: Qmin = 60 m3/h Qmax = End of characteristic curve Flanged end DN 150 Length mm Length mm Outside dia. mm 150 140 (PN 10/16) 148 (PN 25/40) 285 300 Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. Maximum impeller dia. Optimum impeller dia. “b” 79 UPA 300, 350 60 Hz UPA 300 -- 94 for Well Diameters of 300 mm (12 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump UPA 300 -- 94/ ... + ... Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ +30 _C) Ho m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1n 1m 1k 1g 1d 1 + UMA 200D + UMA 200D + UMA 200D + UMA 200D + UMA 200D + UMA 200D 45/21 55/21 55/21 65/21 75/21 90/21 49.0 54.5 62.5 68.1 73.4 78.7 48.0 56.0 62.0 72.0 80.0 95.0 64.4 75.1 83.1 96.6 107.3 127.4 32 34 31 32 31 32 83.0 96.0 105.0 120.0 136.0 162.0 85.7 86.8 86.8 87.6 87.5 88.2 0.86 0.85 0.86 0.86 0.85 0.84 4 x 10 4 x 16 4 x 16 3/4 x 10 II 3) 3/4 x 10 II 3) 3/4 x 16 II 3) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 6.0 4) 3/4 x 10 4) 3/4 x 10 4) 3/4 x 16 4) 2m 2k 2h 2d 2 + UMA 250D 110/21 + UMA 250D 132/21 + UMA 250D 160/21 + UMA 250D 190/21 + UMA 300D 250/22 113.3 131.7 139.7 153.4 167.1 110.0 130.0 145.0 170.0 200.0 147.5 174.3 194.4 228.0 268.2 32 33 34 34 63 188.0 214.0 241.0 291.0 341.0 88.7 89.3 89.7 90.2 89.3 0.83 0.86 0.85 0.82 0.83 3/4 x 16 II 3) 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 35 II 3) 5) 3/3x70 II + 1x35 3) 6) 3/4 x 25 4) 3/4 x 25 4) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 6x95 + 1x50 4) 7) 3k 3h 3e 3c 3 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 205.5 216.8 230.7 240.0 251.5 200.0 220.0 235.0 265.0 295.0 268.2 295.0 315.1 355.4 395.6 63 62 61 59 57 341.0 367.0 386.0 429.0 471.0 89.3 89.7 89.9 90.2 90.4 0.83 0.84 0.85 0.86 0.87 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 4f + UMA 300D 300/22 4c + UMA 300D 300/22 4 + UMA 300D 400/22 300.9 319.4 335.2 315.0 350.0 390.0 422.4 469.4 523.0 59 57 57 513.0 562.0 622.0 90.7 90.9 91.1 0.85 0.86 0.87 6x95 II + 1x50 3) 7) 6x95 II + 1x50 3) 7) 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 5e + UMA 300D 400/22 382.2 390.0 523.0 57 622.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 1) 2) 3) 4) 5) 6) 7) Also see pages 3 and 75 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. 1 x 3--core flat + 1 x 4--core round. 2 x 3--core flat + 1 x 1--core round. 6 x 1--core round + 1 x 1--core round. Dimensions / Weights / Horizontal Installation 1) LP LA ¶ mm mA in ¶ kg Dmax ¶ mm Installation 2) A ¶ mm UPA 300 - 94/ .. ¶ mm Standard Special Standard Special D.o.l Y-∆ 1n 1m 1k 1g 1d 1 775 775 775 775 775 775 2006 2116 2116 2246 2336 2516 2006 2116 2116 2246 2336 2516 253 273 273 296 312 344 268 288 288 311 327 359 279 281 281 286 285 288 286 286 286 285 285 288 v+h v+h v+h v+h v+h v 3) 1006 1061 1061 1126 1171 -- 2m 2k 2h 2d 2 980 980 980 980 980 2509 2639 2749 2899 3053 2509 2639 2749 2899 3053 450 494 531 582 731 471 515 552 603 755 288 299 299 308 331 299 299 308 321 331 v+h v+h v+h v 3) v 4) 1360 1425 1480 --- 3k 3h 3e 3c 3 1155 1155 1155 1155 1155 3228 3228 3228 3228 3228 3228 3228 3228 3228 3228 764 764 764 764 764 793 793 793 793 793 331 331 331 331 331 331 331 331 331 331 v 4) v 4) v 4) v 4) v 4) ------ 4f 4c 4 1330 1330 1330 3583 3583 3703 3583 3583 3703 875 875 927 909 909 961 311 311 311 311 311 311 v 4) v 4) v 3) 4) ---- 5e 1505 3878 3878 960 999 311 311 v 3) 4) -- 1) 2) 3) 4) Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 80 UPA 300, 350 60 Hz UPA 300 -- 94 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 300 -- 94 (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve. Pump efficiency η p: (not considering check valve). NPSH: Net positive suction head required by the pump. Pump End G 8’’ / DN 200 The information is based on the model “with check valve and threaded end”. The changes in the main dimensions of the “flanged end” model or the model “with connection branch” are specified in the table below. a) Check valve with: Threaded end G 8’’ Flanged end DN 200 Length mm Length mm Outside dia. mm 290 240 (PN 10) 240 (PN 16) 244 (PN 25) 340 340 360 b) Connection branch with: Threaded end G 8’’ Operating range: Qmin = 84 m3/h Qmax = End of characteristic curve Flanged end DN 200 Length mm Length mm Outside dia. mm 200 134 (PN 10) 134 (PN 16) 138 (PN 25) 340 340 360 Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. Optimum impeller dia. “b” Maximum impeller dia. 385 81 UPA 300, 350 60 Hz UPA 350 -- 128 for Well Diameters of 350 mm (14 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump UPA 350 -- 128/ ... + ... Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power Max. temperature of the fluid handled v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ 30 _C) Ho m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1l 1k 1h 1f 1d 1b 1 + UMA 200D 55/21 + UMA 200D 75/21 + UMA 200D 90/21 + UMA 250D 110/21 + UMA 250D 132/21 + UMA 250D 160/21 + UMA 250D 190/21 56.9 65.8 74.9 83.2 91.9 100.0 109.0 60.0 78.0 100.0 115.0 135.0 155.0 185.0 80.5 104.6 134.1 154.2 181.0 207.9 248.1 32 32 31 32 32 31 31 101.0 134.0 169.0 195.0 222.0 254.0 311.0 86.8 87.5 88.2 88.7 89.3 89.6 90.2 0.86 0.84 0.85 0.84 0.86 0.86 0.83 4 x 16 3/4 x 10 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 35 II 3) 5) 3/4 x 6.0 4) 3/4 x 10 4) 3/4 x 16 4) 3/4 x 25 4) 3/4 x 25 4) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 2h 2g 2e 2c 2b 2 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 300/22 + UMA 300D 300/22 154.9 162.6 174.6 189.0 204.1 220.4 205.0 220.0 245.0 280.0 315.0 360.0 274.9 295.0 328.6 375.5 422.4 482.8 62 62 60 58 59 57 347.0 367.0 400.0 450.0 513.0 575.0 89.5 89.7 90.1 90.3 90.7 91.0 0.83 0.84 0.86 0.87 0.85 0.87 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 6x95 II + 1x50 3) 7) 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 3c + UMA 300D 400/22 282.3 415.0 556.5 56 658.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 1) 2) 3) 4) 5) 6) 7) Also see pages 3 and 75 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. 1 x 3--core flat + 1 x 4--core round. 2 x 3--core flat + 1 x 1--core round. 6 x 1--core round + 1 x 1--core round. Dimensions / Weights / Horizontal Installation 1) LP LA ¶ mm mA in ¶ kg Dmax ¶ mm Installation 2) A ¶ mm UPA 350 -- 128/ .. ¶ mm Standard Special Standard Special D.o.l Y-∆ 1l 1k 1h 1f 1d 1b 1 898 898 898 898 898 898 898 2239 2459 2639 2427 2557 2667 2817 2239 2459 2639 2427 2557 2667 2817 289 328 360 432 476 513 564 308 347 379 452 496 533 584 316 320 324 324 334 334 343 322 320 324 334 334 343 357 v+h v+h v 3) v+h v+h v+h v 3) 1119 1229 ---1213 1278 1333 ---- 2h 2g 2e 2c 2b 2 1108 1108 1108 1108 1108 1108 3181 3181 3181 3181 3361 3361 3181 3181 3181 3181 3361 3361 764 764 764 764 842 842 793 793 793 793 871 871 360 360 360 360 341 341 360 360 360 360 341 341 v 4) v 4) v 4) v 4) v 4) v 4) ------------------- 3c 1308 3681 3681 936 970 341 341 v 3) 4) ---- 1) 2) 3) 4) Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 82 UPA 300, 350 60 Hz UPA 350 -- 128 / .. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 350 -- 128 (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 8’’ / DN 200 1) The information is based on the model “with check valve and threaded end”. The changes in the main dimensions of the “flanged end” model or the model “with connection branch” are specified in the table below. a) Check valve with: Threaded end G 8’’ Flanged end DN 200 Length mm Length mm Outside dia. mm 328 278 (PN 10) 278 (PN 16) 340 b) Connection branch with: Threaded end G 8’’ Flanged end DN 200 Length mm Length mm Outside dia. mm 169 123 (PN 10) 123 (PN 16) 340 Operating range: Qmin = 120 m3/h Qmax = End of characteristic curve Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. 1) DN 250 check valve (with flanged end only) on request. For relevant head losses see HV curve plotted over Q. Optimum impeller dia. “c” Maximum impeller dia. 448 365 -- pedestals for motor 440 -- pedestals for pump 83 UPA 300, 350 60 Hz UPA 350 -- 180 for Well Diameters of 350 mm (14 inches) and Above Pumps with submersible motors for ... Pump unit -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆) Pump UPA 350 -- 180/ ... + ... Motor lead 2), flat Motor Discharge head Q = 0 m3/h Rated power of the fluid handled Max. temperature v ≥ 0.5 m/s Rated current Efficiency Power factor Number x cross-section of conductors (use under water, 460 V and ≤ 30_C) Ho m PN kW PN hp tmax 1) _C IN A ηM % cos φ ---- D.o.l. mm2 Y-∆ mm2 1m 1l 1h 1e 1c 1 + UMA 200D 90/21 + UMA 250D 110/21 + UMA 250D 110/21 + UMA 250D 132/21 + UMA 250D 160/21 + UMA 250D 190/21 59.3 66.0 71.0 80.8 89.7 96.3 95.0 110.0 115.0 135.0 150.0 175.0 127.4 147.5 154.2 181.0 201.2 234.7 32 33 31 32 33 33 162.0 188.0 195.0 222.0 247.0 297.0 88.2 88.7 88.7 89.3 89.7 90.2 0.84 0.83 0.84 0.86 0.85 0.82 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 16 II 3) 3/4 x 25 II 3) 3/4 x 25 II 3) 3/4 x 35 II 3) 5) 3/4 x 16 4) 3/4 x 25 4) 3/4 x 25 4) 3/4 x 25 4) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 2k 2g 2f 2d 2b 2 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 300/22 + UMA 300D 300/22 141.7 149.9 164.3 177.6 189.0 198.2 230.0 245.0 265.0 290.0 320.0 360.0 308.4 328.6 355.4 388.9 429.1 482.8 61 60 59 57 59 57 381.0 400.0 429.0 463.0 521.0 575.0 89.9 90.1 90.2 90.4 90.8 91.0 0.85 0.86 0.86 0.87 0.85 0.87 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 3/3x70 II + 1x35 3) 6) 6x95 II + 1x50 3) 7) 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 6x95 + 1x50 4) 7) 3f + UMA 300D 400/22 244.5 405.0 543.1 56 642.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7) 1) 2) 3) 4) 5) 6) 7) Also see pages 3 and 75 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing. 2 cables in parallel. Delta wiring in the cable connector or control cabinet. 1 x 3--core flat + 1 x 4--core round. 2 x 3--core flat + 1 x 1--core round. 6 x 1--core round + 1 x 1--core round. Dimensions / Weights / Horizontal Installation 1) LP mA in ¶ kg Installation 2) A ¶ mm Standard Special Standard Special D.o.l Y-∆ 898 898 898 898 898 898 2639 2427 2427 2557 2667 2817 2639 2427 2427 2557 2667 2817 360 432 432 476 513 564 379 452 452 496 533 584 324 324 324 334 334 343 324 334 334 334 343 357 v 3) v+h v+h v+h v+h v 3) ---1213 1213 1278 1333 ---- 2k 2g 2f 2d 2b 2 1108 1108 1108 1108 1108 1108 3181 3181 3181 3181 3361 3361 3181 3181 3181 3181 3361 3361 764 764 764 764 842 842 793 793 793 793 871 871 360 360 360 360 341 341 360 360 360 360 341 341 v 4) v 4) v 4) v 4) v 4) v 4) ------------------- 3f 1308 3681 3681 936 970 341 341 v 3) 4) ---- Including check valve with threaded end and standard motor leads. v = vertical; h = horizontal. Horizontal installation on request. Horizontal installation only with bearing pedestals of special design. 84 Dmax ¶ mm 1m 1l 1h 1e 1c 1 UPA 350 - 180/ .. 1) 2) 3) 4) LA ¶ mm ¶ mm UPA 300, 350 60 Hz UPA 350 -- 180 /.. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. UPA 350 -- 180 (Tolerances to ISO 9906 Class 2) Selection The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve η p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump Pump End G 8 / DN 200 1) The information is based on the model “with check valve and threaded end”. The changes in the main dimensions of the “flanged end” model or the model “with connection branch” are specified in the table below. a) Check valve with: Threaded end G 8’’ Flanged end DN 200 Length mm Length mm Outside dia. mm 328 278 (PN 10) 278 (PN 16) 340 b) Connection branch with Threaded end G 8’’ Flanged end DN 200 Length mm Length mm Outside dia. mm 169 123 (PN 10) 123 (PN 16) 340 Operating range: Qmin = 144 m3/h Qmax = End of characteristic curve Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN EN 1092--2. 1) DN 250 check valve (with flanged end only) on request. For relevant head losses see HV curve plotted over Q. 448 365 -- pedestals for motor 440 -- pedestals for pump 85 60 Hz 86 UPA 300, 350 60 Hz Applications BSX, BSF Submersible Borehole Pumps Transport of pure and natural water for ... -- general water procuring and supplying, -- irrigation and sprinkling, -- ground-water lowering and maintaining in open-work mining, -- water maintaining and draining of galleries in underground mining. for Well Diameters of 400 mm (16 inches) and Above single-flow and mixed-flow In addition in pressure-boosting plants and sprinkler installations as well as in offshore and cavern technologies etc. Admissible contents of sand in the liquid handled: 50 g/m3. Operating Data Capacity . . . . . . . . . . . . . . . . . . . Q up to 2200 m3/h (610 l/s or up to 10,000 US GPM) Head . . . . . . . . . . . . . . . . . . . . . . H up to 240 m Temperature of liquid handled . t up to + 50 oC Speed . . . . . . . . . . . . . . . . . . . . . n ≈ 1750 rpm Design Single- or multi-stage, single-flow centrifugal pumps in ring-section design. For vertical, angled and horizontal installation. Mixed-flow hydraulics with reducibles impellers. The stage casings are connected by means of studs. Suction casing between pump and motor with suction strainer as protection of pump against coarse impurities of the liquid handled. Pump end at choice with non-return valve or connection nozzle. Either design with flanged connection. Especially suitable for installation in narrow deep wells. Designation B R Z S Type series Design status Minimum well diameter (mm) 1) Suction impeller Code for hydraulics (50 Hz) Number of stages Impellers reduced 1) X = 400 mm (16 inches), Y = 450 mm (18 inches), Z = 500 mm (20 inches), E = 600 mm (24 inches), F = 650 mm (26 inches) Certification Quality management certified to ISO 9001 535 / 5 a Product Features --------- Very sturdy design Suitable for installation in narrow deep wells High efficiency Motor designed for maximum pump output Low noise level For vertical or horizontal installation Non-return valve protected against blocking Pre-filled motor without risk of contamination of the pumped water 87 BSX, BSF 60 Hz Selection Chart (Ranges on Offer) U.S.gpm 1000 n ≈ 1750 rpm 1400 Imp.g.p.m. 1000 2000 1400 4000 3000 2000 3000 6000 4000 10000 6000 10000 700 2000 500 400 1000 300 BRY 504 H m 200 BRZS 535 BRE 555 BSX 463 BSF 586 500 150 400 100 80 300 H ft 60 200 50 40 100 30 80 20 60 15 40 10 200 40 60 300 80 400 100 500 Q m3/h Q l/s 200 1000 300 2000 400 600 3000 800 3430:80 88 60 Hz Materials Component Drive Execution G Execution B Cast iron JL1030 (GG-20) Bronze (G-CuSn10) Pump ... Casing Impeller Shaft Bronze (G-CuSn10) Cr steel (1.4021) Wear rings Bearings BSX, BSF CrNiMo steel (1.4462) KSB submersible motors DN 300 and above in squirrel-cage design, three-phase current (3~), 4 poles. For low (U = 1000 V) and high (U = 6000V) voltage. Water-filled motor. The water fill lubricates the bearings and cools the windings sealed with water-tight insulation material. The shaft is sealed by lip seals protected against ingress of sand or a mechanical seal. Pressure differences between motor and environment are equalized by a rubber expansion diaphragm in the motor. Construction complies with VDE regulations. Bronze (2.1090) Cr steel (1.4021) annealed / special bronze Component Alu bronze (G-CuAl11Ni) / special bronze Execution G Motor ... Shaft Cast parts Steel (C 45) enclosed Cast iron JL1030 (GG-20) Stator jacket Steel (St 37) Electrical Connection The motors are equipped ex works with 2 short cables. Generally with earthing. Connection of extension cable by means of a waterproof cable connector. At choice connection of the complete cable length direct at the winding in the submersible motor. Short cable and extension cable for low voltage (U ≤ 1000 V) in food quality. Starting Methods Bearings / Lubrication Pump: 1 radial plain bearing in suction casing and in bearing bracket housing resp. in last stage (BSF 586). Dependent on pump size and number of stages additionally 1 intermediate bearing. Lubricated by the liquid handled. Motor: 2 radial plain bearings and 1 thrust bearing with tilting pads for balancing of axial thrust. Lubricated by the motor fill water. Low voltage (U ≤ 1000 V): direct on line (without or with starting transformer as well as with smooth running device) and star-delta. High voltage (U > 1000 V): only direct on line. Application Temperatures The submersible units are so designed as to allow also operation without additional cooling in the motor area, e.g. installation in a deep well, in a big tank etc. (the liquid handled does not stream directly along the motor). Right-handed, i.e. clockwise rotation (viewed at the drive shaft end). With additional cooling, e.g. installation in the deep well above the filter area, execution with cooling shroud etc. (the liquid handled streams along the motor with v ≥ 0.5 m/s), the submersible units can be used in water of elevated temperatures (additionally 5 °C and more). Pump End (Discharge Nozzle) Designs on Request Direction of Rotation of the Pump Flange DN 200 up to DN 400 dependent on pump size. Coating (Standard) Quality . . . . . . . . . . . 2-component high-build coating (epoxy resin base), approved for drinking water contact Structure . . . . . . . . . Primer and top coat Thickness of coat . 100 to 150 µm. --------- other material designs higher temperatures of liquid handled higher voltages until 6600 V other frequencies more wear resistant design with cooling, suction or pressure shroud special coating motor in special design (solidly/sealed against high pressure, flameproof, etc.) Colour . . . . . . . . . . . ultramarine blue (RAL 5002). Mode of Installation Generally vertical installation. Dependent on number of stages and the motor size also horizontal installation possible. 89 BSX, BSF 60 Hz Design Features The coating and the cable in food quality (BAM)1) -- For use without any problems in drinking water area. The non-return valve with doubleguided valve plate -- No jamming or canting. -- With valve plate spring loaded. Thus allows minimum closing-times and avoids consequently waterhammers. 1) German federal inst. for materials research The enclosed pump bearing -- Maintenance-free and extensively protected against wear. -- Long-term operation without problems. The steadfast wear rings -- Replaceable rings (standardly with casing and impeller wear ring) out of wear- and corrosion-resistant metal. -- They protect against gap wear and allow easy servicing. The mixed-flow impellers -- Reducibles. Thus caused optimum adaptation to need of pump heads. -- With keys for reliable power transmission and simplified dismantling and mounting. The pump shaft out of stainless steel -- Completely protected by means of sleeves against direct wear caused by the liquid handled. Stainless steel union elements -- All screws and nuts of superior alloy steel (CrNiMo). -- That is a guarantee for a high degree of functional reliability and a considerably simplified dismantling. The motor KSB -- Acc. to VDE standards, i.e. a high level of electric safety. -- Designed for max. possible pump power consumption and thus protected against overload. The dynamically balanced rotor -- It ensures an optimum quietness of running. The counter thrust bearing -- It balances the negative axial thrust. -- Thus it prevents reliably butting of the impellers against the stage casings. The reliable pressure balancing system -- Optimum design of rubber diaphragm. -- Therefore largest possible immersion depths. The proven thrust bearing -- Water-lubricated plain bearing with self-adjusting tilting pads. -- This allows absolutely maintenance-free operation and maximum loads under continuous duty conditions. 3411:11 90 60 Hz Applications Handling clean and raw water in applications such as: -- general water extraction / supply, -- irrigation and spray irrigation, -- lowering and maintaining ground water levels in open-cast mines, -- dewatering and gallery drainage in underground mines. UPZ Submersible Borehole Pumps for Well Diameters of 500 mm (20 inches) and Above Double entry, back-to-back impeller arrangement Use in pressure-boosting and sprinkler systems, as well as for offshore and cavern applications, etc. Permissible sand content in the fluid handled: 50 g/m3. Operating Data Capacity . . . . . . . . . . . . . . . . . . . Q up to 2200 m3/h (612 l/s or up to 10,000 US GPM) Head . . . . . . . . . . . . . . . . . . . . . . H up to 1500 m Supply voltage . . . . . . . . . . . . . . U up to 6600 V Temperature of fluid handled . . t up to +40 oC Speed . . . . . . . . . . . . . . . . . . . . . n 3500 rpm and 1750 rpm Design Multistage, double-entry ring-section pump with back-to-back impeller arrangement. For vertical installation. Radial and mixed-flow hydraulic systems with impellers that can be turned down. Half the flow enters the pump through the lower suction casing, the other half through the upper suction casing. The upper half of the pump unit is surrounded by a pump shroud (outer shell). The two flows are collected by the channel created by the shroud and carried into the upper suction casing, which is equipped with two discharge branches. This design theoretically ensures full axial thrust balancing. The casing components (stage casings) are connected by means of round tie bolts. The two suction casings are equipped with strainers to protect the pump from coarse particles in the fluid. Flanged pump end. Check valve with flanged end available on request. Particularly suitable for installation in narrow deep wells. Pump Designation (Example) UPZ 160 -- 228 / 8 Type series Capacity Qopt (l/s) Nominal impeller diameter (mm) Number of stages Certification Quality management certified to ISO 9001 91 UPZ 60 Hz Selection Chart (Ranges on Offer) U.S.gpm n ≈ 3500 rpm and n ≈ 1750 rpm 500 1000 200 Imp. g. p. m. 500 2000 1000 5000 2000 2000 10000 5000 6000 UPZ ... 1500 5000 4000 1000 n = 1450 1/min 3000 H m 2000 500 H ft 400 300 1000 n = 2900 1/min 800 700 200 600 500 150 400 100 300 200 50 40 50 100 20 30 Q m3/h 200 50 300 400 500 100 Q l/s 1000 200 300 2000 500 3470:1 Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this flow range. 92 60 Hz UPZ Materials Coating (Standard) The choice of materials depends on the capacity and discharge head. For cast iron models only. Component Pump Casing Impeller/ Diffuser Cast iron (GJL-200) Nodular cast iron (GJS-600) Bronze (CuSn10) Aluminium bronze (CuAl10Ni) CrNi steel Bronze (CuSn10) Aluminium bronze (CuAl10Ni) CrNi steel Shaft CrNi steel (1.4057) CrNiMo steel (1.4462) Wear ring Aluminium bronze (CuAl10Ni) CrNiMo steel Bearings Screws, bolts and nuts 1) Chrome steel (1.4021), hard chrome plated / special bronze or other special materials CrNiMo steel Motor Quality . . . . . . . . . . . . . . 2-component high-build coating (epoxy resin base), approved for drinking water contact. Coating structure . . . . . Primer and top coat Film thickness . . . . . . . 100 to 150 µm Colour . . . . . . . . . . . . . . ultramarine blue (RAL 5002) Type of Installation In general, the pumps are installed vertically. Drive KSB submersible squirrel-cage motor, 2 or 4 poles. Three-phase current (3~). For supply voltages up to U = 6600 V. Water-filled motor. The water fill lubricates the bearings and cools the windings sealed with water-tight insulation material. Internal cooling circuit. The shaft is sealed by lip seals or a mechanical seal protected from ingress of sand. Pressure differences between motor and environment are equalized by a rubber expansion diaphragm in the motor. Shaft Steel (1.0503+N), protected Cast parts Cast iron (GJL-200) Bronze (CuSn10) Aluminium bronze (CuAl10Ni) CrNi steel Motor design is in compliance with VDE regulations. Stator case St 37, CrNiMo steel The motors are supplied ex factory with 1 or 2 motor leads. Screws, bolts and nuts 1) CrNiMo steel Any extension cables required are connected using cable connectors. On request, the entire length of cable required can be connected to the motor at the factory. All motor sizes are available either with or without earth conductor. 1) in contact with fluid handled Bearings / Lubrication Pump: 1 radial plain bearing in each suction casing. Depending on the pump size and number of stages, 1 additional intermediate bearing each in the two pump halves. Lubricated by the fluid handled. Motor: 2 radial plain bearings. Residual axial thrust is balanced by 1 self-aligning tilting-pad thrust bearing in the motor (lower end). Lubricated by the motor’s water fill. Direction of Rotation of the Pump Clockwise rotation (when looking at the drive shaft end). Connection to Power Supply Starting Low voltage (U ≤ 1000 V): d.o.l. (without or with autotransformer / with or without soft starter) and star-delta (Y-∆)starting. High voltage (U > 1000 V): d.o.l starting only. Variants Available on Request ------- Other materials Higher fluid temperatures More wear-resistant designs Models with cooling or pump shroud Special coating Special explosion protection up to 6 kV Pump End (Discharge Nozzle) With DN 200 to DN 350 flanges to DIN 2526 and 2512, depending on the pump size. 93 UPZ 60 Hz Design Features Robust wear rings -- Replaceable wear rings made of wear- and corrosion-resistant metal. -- Protection against wear in the clearance; easy servicing. Enclosed pump bearing -- No--maintenance design, high wear resistance. -- For trouble-free long-term operation. Pump shroud -- Slim, low-weight design. -- High operating reliability because of simple sealing of high-pressure section. Stainless steel pump shaft -- Fully protected by impeller hubs and sleeves from direct wear caused by the fluid handled. Impellers -- Can be turned down. -- This means pump performance can be matched exactly to head requirements in the system. Double-entry design with impellers in back-to-back arrangement -- Low wear thanks to low velocities in the pump and use of special materials. -- Designed to ensure full hydraulic thrust balancing, irrespective of any wear in the sealing clearances. -- Considerably reduced load on the thrust bearing. -- This allows high discharge heads at relatively large flow rates. Stainless steel union elements -- All wetted bolts, screws and nuts are made of CrNiMo steel. -- High operating reliability. Wear-resistant mechanical seal -- Long service life and high operating reliability. Circulation cooling through double shroud -- Low temperature rise Motor can be filled with drinking water -- Simply top up whenever needed. Winding insulation (J2) -- Cu--VPE--PA material makes for maximum heat resistance. Tried and tested thrust bearing -- New materials combination (stainless steel / carbon) for high safety factor. Sealing elements -- All joints sealed by O-rings. Pressure--proof up to a differential pressure of 16 bar. 94 High efficiency ηM -- Reduced operating costs thanks to optimized windings. Optimized cooling pump -- No peak temperatures. Reliable pressure balancing system -- Optimum selection thanks to generously sized rubber diaphragm. -- Enables installation at very low depths. 60 Hz Submersible Borehole Pumps Typical Tender for S 100D No. Q Quantity i Item Unit p price E Euro Amount E Euro Submersible borehole pump(s) type S 100D for well diameters of 100 mm (4 inches) and above Make: KSB Pump + motor: S 100D -- . . . . . . / . . . . . + . . . . . . . . . . . . . . kW Multistage centrifugal pump for vertical / angled / horizontal 1) installation. Integrated, check valve with double-guided valve disc. Plain bearing lubricated by the fluid handled and protected against ingress of sand. Discharge nozzle with threaded end. Submersible canned motor for three-phase current, with self--aligning thrust bearing, expansion diaphragm for pressure equalization and cable kit 1.5 / 2.5 1) m power supply cable. Max. permissible submergence below maximum water level: 350 m. Fluid handled: clean or slightly contaminated water with a permissible sand content of up to 50 g/m3! Outer pump casing, suction casing and check valve housing . . . . . . . . . . . . . . . . . . . . . . . . Stage casing (diffuser) . . . . . . . . . . . . . . . . . . . . . Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shaft (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bearing (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor (shaft and housing) . . . . . . . . . . . . . . . . . . Capacity . . . . . . . . . . . . . . . . Head . . . . . . . . . . . . . . . . . . . Temperature (fluid handled) Rated power (motor) . . . . . . Speed / Frequency . . . . . . . Voltage / Starting . . . . . . . . . Pump end . . . . . . . . . . . . . . . Outside diameter . . . . . . . . . Pump set length / weight . . Q = H = t = PN = n ¶ U = G Dmax= LA ¶ CrNi steel glass fibre reinforced NORYL glass fibre reinforced NORYL Chrome steel Rubber CrNi steel m3/h / kW / rpm / f = V/ d.o.l. 11/4’’ (DN 32) / 2’’ (DN 50) 1) mm / GA ¶ l/s m oC hp Hz mm kg Adapter from G 11/4’’ to R 11/2’’ . to flanged end DN . Adapter from threaded end G Pair of supporting and installation clamps for risers R11/4’’ (DN 32) / R2’’ (DN 50)1). Cooling shroud with suction strainer and pedestals for horizontal installation. Power supply cable x mm2, separate/connected 1), length m. 1) Cable connector, separable / non-separable , with sealing compound, motor supply cable not connected and sealed/connected and sealed1) at the factory. Cable tie UPA CONTROL box for 3 µ/ 400 V with thermal overcurrent relay with phase failure protection, temperature-compensated, insulating enclosure, with 3 electrodes and integrated ”Dry running protection” / ”Water level control” selector switch. Motor contactor for 1 µ/ 230 V with ON/OFF switch for automatic operation, insulating enclosure. Dry running protection equipment: -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of m each. Lightning protection with earthing terminal for 3 µ 400 V. Automatic control unit Controlmatic E / Cervomatic EDP1). Sum total 1) Delete as applicable 95 60 Hz Submersible Borehole Pumps Typical Tender UPA 100C No. Qty Unit p price Item Submersible borehole pump(s) type UPA 100C for well diameters of 100 mm (4 inches) and above. Marke: Pump + motor: KSB UPA 100C -- / + Multistage centrifugal pump for vertical / angled / horizontal 1) installation. Components of stainless steel with a minimum wall thickness of 1 mm and vanes welded at 6 points. Integrated check valve. Generously dimensioned plain bearing lubricated by the fluid handled. Discharge nozzle with threaded end. Submersible canned motor for three-phase current, with self--aligning thrust bearing, expansion diaphragm for pressure equalization and cable kit 1.5 / 2.5 1) m power supply cable. Max. permissible submergence below maximum water level: 350 m. Fluid handled: clean or slightly contaminated water with a permissible sand content of up to 50 g/m3. Suction and discharge casing . . . . . . . . . . . . . . . CrNi steel Diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel Shaft (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel Bearing (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . Rubber Motor (shaft and housing) . . . . . . . . . . . . . . . . . . CrNi steel m3/h / l/s Capacity . . . . . . . . . . . . . . . . . . . Q = Head . . . . . . . . . . . . . . . . . . . . . . H = m Temperature (fluid handled) . . . t = °C Rated power (motor) . . . . . . . . . PN= kW / hp Speed / Frequency . . . . . . . . . . n ≈ rpm / f = Hz Voltage / Starting . . . . . . . . . . . . U = V/ direct Pump end . . . . . . . . . . . . . . . . . . Rp 11/2’’ (DN 40) / 2’’ (DN 50) 1) Outside diameter . . . . . . . . . . . . Dmax= mm Pump set length / weight . . . . . LA ≈ mm/GA≈_____kg Adapter from G to DN . Pair of supporting and installation clamps for risers Rp 11/2’’ (DN 40) / R2’’ (DN 50)1). Power supply cable length x mm2, separate / connected1), m Cable connector, separable / non-separable1), with sealing compound,motor supply cable not connected and sealed / connected and sealed1) at the factory. Cable tie UPA CONTROL box for 3~ / 400 V with thermal overcurrent relay with phase failure protection, temperature-compensated, insulating enclosure, with 3 electrodes and integrated ”Dry running protection” / ”Water level control” selector switch. Motor contactor for 1~ / 230 V with ON / OFF switch for automatic operation, insulating enclosure. Dry running protection equipment: -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of m each. Lightning protection with earthing terminal for 3~ 400 V. Sum total 1) Delete as applicable 96 Amount 60 Hz Submersible Borehole Pumps Typical Tender UPA 200, 200B, 250C No. Qty Unit p price Item Amount Submersible borehole pump(s) type UPA 200 / 200B / 250C 1) for well diameters of 200 mm (8 inches) and above. Make: Pump + motor: KSB UPA -- / + Multistage centrifugal pump in ring-section design for vertical / horizontal 1) installation. Radial or mixed-flow hydraulic systems with impellers that can be turned down. Pump bearing lubricated by the fluid handled and protected against ingress of sand. Integrated check valve with anti-blockage, spring-loaded valve disc / connection branch. Pump end with internal thread / flange 1). Suction casing with suction strainer fitted between pump and motor. Pre-filled submersible motor. Three-phase current. Squirrel-cage design with self-aligning thrust bearing and adequately sized expansion diaphragm for pressure equalization. Design in compliance with VDE standards. IP 68 enclosure. With power supply cables. Required flow velocity past the motor: v ≥ 0.5 m/s. Fluid handled: clean to slightly contaminated water, slightly aggressive / more aggressive / as specified in water analysis1) , with a permissible sand content of up to 50 g/m3. Casings . . . . . . . . . . . . . . . . . . . . . . . . . . . . cast iron / bronze 1) Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . glass fibre reinforced NORYL/ bronze 1) (UPA 200/200B) / bronze (UPA 250C) Wear rings . . . . . . . . . . . . . . . . . . . . . . . . . bronze Shaft (pump + motor) . . . . . . . . . . . . . . . . Chrome / CrNiMo steel 1) Stator case (motor) . . . . . . . . . . . . . . . . . . CrNi / CrNiMo steel 1) Bolts, screws and nuts . . . . . . . . . . . . . . . CrNiMo steel (A4--70) m3/h / l/s Capacity . . . . . . . . . . . . . . . . . . . . . Q = Head . . . . . . . . . . . . . . . . . . . . . . . . H = m m Shut-off head . . . . . . . . . . . . . . . . . Ho = % / Motor % Efficiency . . . . . . . . . . . . . . . . . . . . η Pump °C Temperature (fluid handled) . . . . . t = hp / IN = A Rated power / amperage . . . . . . . PN = Speed / Frequency . . . . . . . . . . . . n ≈ rpm / f = Hz V Supply voltage . . . . . . . . . . . . . . . . U = Starting . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. / star-delta 1) Pump end . . . . . . . . . . . . . . . . . . . . G3’’ (DN 80) / G5’’ (DN 125) / G6’’ (DN 150) 1) mm Outside diameter . . . . . . . . . . . . . . Dmax= Economic efficiency analysis (for ex. for 10 years): Operating period per year approx. h/ Electricity costs /kWh. Pump data tolerances to ISO 9906 Class 1. During the acceptance test, the overall efficiency may be max. 3 percentage points lower than the overall efficiency quoted (η ”pump” x η ”motor”). Adapter, from threaded end G standard / special 1). to flange DN Pair of supporting and installation clamps for riser R / DN 1) Set of bearing pedestals for horizontal installation without / tank. Power supply cable, separate/connected 1), with1) mm2, length . water storage m. Cable connector, size , with sealing compound, motor supply not connected and sealed / connected and sealed 1) at the factory. Cable tie, size . Dry running protection equipment -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of m each. Temperature monitoring equipment Pt 100 for use in submersible motors to protect the windings from overheating; it consists of a resistance thermometer with measuring line and does not include / includes1) a display unit. Sum total 1) Delete as applicable 97 60 Hz Submersible Borehole Pumps Typical Tender for UPA 300, 350 No. Qty Unit p price Item Submersible borehole pump(s) type UPA 300 / 350 1) for well diameters of 300 mm (12 inches) and above. Make: Pump + motor: KSB UPA -- / + Multistage centrifugal pump in ring-section design for vertical / horizontal 1) installation. Mixed flow hydraulic systems with impellers that can be turned down. Pump bearing lubricated by the fluid handled and protected against ingress of sand. Integrated check valve with anti-blockage, spring-loaded valve disc / connection branch. Pump end with internal thread / flange 1). Suction casing with suction strainer fitted between pump and motor. Pre-filled submersible motor. Three-phase current. Squirrel-cage design with selfaligning thrust bearing and adequately sized expansion diaphragm for pressure equalization. Design in compliance with VDE standards. IP 68 enclosure. With power supply cables. Required flow velocity past the motor: v ≥ 0.5 m/s. Fluid handled: clean to slightly contaminated water, slightly aggressive / more aggressive / as specified in water analysis1) , with a permissible sand content of up to 50 g/m3. Casings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cast iron / bronze 1) Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bronze Wear rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bronze Shaft (pump + motor) . . . . . . . . . . . . . . . . . . . . . . . . . Chrome / CrNiMo steel 1) Stator case (motor) . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNiMo steel Bolts, screws and nuts . . . . . . . . . . . . . . . . . . . . . . . . CrNiMo steel (A4) Capacity . . . . . . . . . . . . . . . . . . . . . Q = m3/h / l/s Head . . . . . . . . . . . . . . . . . . . . . . . . H = m m Shut-off head . . . . . . . . . . . . . . . . . Ho = % / Motor % Efficiency . . . . . . . . . . . . . . . . . . . . η Pump °C Temperature (fluid handled) . . . . . t = hp / IN = A Rated power / amperage . . . . . . . PN = Speed / Frequency . . . . . . . . . . . . n ≈ rpm / f = Hz V Supply voltage . . . . . . . . . . . . . . . . U = Starting . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. / star-delta 1) Pump end . . . . . . . . . . . . . . . . . . . . G6’’ / G8’’ / DN 150 / DN 200 / DN 250 1) mm Outside diameter . . . . . . . . . . . . . . Dmax= Economic efficiency analysis (for ex. for 10 years): Operating period per year approx. h/ Electricity costs /kWh. Pump data tolerances to ISO 9906 Class 1. During the acceptance test, the overall efficiency may be max. 3 percentage points lower than the overall efficiency quoted (η ”pump” x η ”motor”). Pair of supporting and installation clamps for riser R / DN 1). . Set of bearing pedestals for horizontal installation without / with1) water storage tank. Power supply cable, separate / connected 1), mm2, m length. Cable connector, size , with sealing compound, motor supply not connected and sealed / connected and sealed 1) at the factory. Cable tie, size . Dry running protection equipment -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of m each. Temperature monitoring equipment Pt 100 for use in submersible motors to protect the windings from overheating; it consists of a resistance thermometer with measuring line and does not include / includes1) a display relay. Sum total 1) Delete as applicable 98 Amount 60 Hz Submersible Borehole Pumps 99 Submersible Motors 60 Hz Submersible Motors for Well Diameters of 100 mm (4 inches) and above DN 100, 150, UMA 150D, 200D, 250D and 300D Sizes / Connection DN 100, DN 150, UMA 150D, UMA200D: NEMA standard UMA 250D, UMA 300D: KSB standard Material Variants (Material specifications to EN) DN 100 Component All components G (Standard) CrNi steel 433 412.53 914.53 550.53 723 710 829 828 829 504 932.52 940.52 271 160.52 900.52 145 DN 150 Component Shaft Bearing carrier Stator case G (Standard) CrNi steel Cast iron (JL1030) 4) CrNi steel 901.51 550.52 UMA Components G (Standard) C1 (Special) C3 (Duplex) 914.52 529 Shaft CrNi steel (1.4305 2) ) CrNiMo steel (1.4462 2) ) CrNiMo steel ((1.4462)) 382.52 CrNiMo steel(1.4462) Cast iron CrNiMo steel (JL1030 4) / (1.4408 / JL 1040 5) 6) ) 1.4409 2) / 1.4517 5) ) CrNiMo steel (1.4539 / 1.4517 5) ) 818 Housing Stator case Screws, bolts and nuts 3) 2) 3) CrNi steel (1.4301) CrNiMo steel (1.4571 / 1.4462 5) ) CrNiMo steel (A4-70) UMA 150D motors only Wetted by fluid pumped. 545 CrNiMo steel ( 1.4539 / 1.4462 5) ) 81--59 23--2 CrNiMo steel ( 1.4539 / 1.4462 5) ) 4) 5) 6) DIN mat. code: GG-20 UMA 300D motors only DIN mat. code: GG-25 814 545 382.51 Bearings / Lubrication Two radial plain bearings as well as a thrust bearing to balance the pump’s axial thrust. Lubrication by motor fill liquid. Direction of Rotation of the Motor 529 900.51 940.51 389 932.51 412.51 387 32--2 392 903 384 Anti-clockwise rotation (when looking at the drive shaft end). Variants Available on Request -- DN 100: Other supply voltages up to 500 V -- UMA 150D -- 300D: Other supply voltages up to 1000 V Part No. 145 Description Adapter 354 382.51/52 384/387 389 Thrust bearing housing Bearing carrier (bottom) / (top) Thrust bearing plate / segment Counter thrust bearing ring 433 59-12 Mechanical seal Membrane 529/545.51 81-59 818 828/829.51 Bearing sleeve / Bearing bush Stator with windings Rotor Cable grommet / Cable gland ring 100 412.52 914.51 550.51 59--6 904.52 381 904.51 553 354 484 160.51 500.51 59--42 920.51 916.51 59--12 950 500.52 e.g. UMA 250 D 60 Hz Submersible Motors Submersible Motors DN 100, UMA 150D to 300D: 3~, n≈ 3500 1/min, d.o.l. + Y-∆ IN PN ηM cos Cu ∅ φ 3~ D (submerged) m Standard 460 V 4/4 4/4 d.o.l. Y-∆ kW hp A % -- mm2 mm2 0.59 0.83 1.0 1.4 1.8 2.5 3.4 4.2 6.4 8.6 0.8 1.1 1.3 1.9 2.4 3.4 4.5 5.6 8.6 11.6 1.5 2.1 2.4 3.1 4.1 5.6 7.4 8.7 13.1 17 70 73 72 74 74 77 79 78 78 78 0.76 0.74 0.79 0.82 0.80 0.77 0.76 0.79 0.82 0.82 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 ------------------------------- 5/21 7/21 9/21 13/21 15/21 18/21 22/21 26/21 30/21 37/22 6.6 9 11.2 15.6 18 22.2 26.4 31.2 36 44 9 12.2 15.2 21.2 24.5 30.2 35.9 42.4 49 59.8 13.4 17.5 21.2 28.9 32.5 40.2 47.2 54.8 63.8 77.4 76 77.5 79 82 83 83 85 85.5 86 85.5 0.82 0.84 0.84 0.83 0.84 0.84 0.83 0.83 0.83 0.84 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 3/4 x 4.0 2) 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 37/21 45/21 55/21 65/21 75/21 90/21 45 55 66 77 90 118 61 75 90 105 122 161 78 94 112 129 153 167 86 87 88 88.5 88 89 0.85 0.85 0.85 0.84 0.84 0.84 3/4 x 10 2) 3/4 x 6 2) 3/4 x 6 2) 3/4 x 10 2) 3/4 x 10 2) 3/4 x 16 2) 3/4 x 10 3/4 x 6 3/4 x 6 3/4 x 10 3/4 x 10 3/4 x 16 85/21 110/21 132/21 160/21 190/21 102 132 158 192 228 138 180 215 261 310 169 218 258 312 369 88 88.5 89 89.5 89.5 0.86 0.86 0.86 0.87 0.87 3/4 x 10 II 3/4 x 25 2) 3/4 x 25 2) 3/4 x 25 II 3/4 x 35 II 3/4 x 16 3/4 x 25 3/4 x 25 3/4 x 35 3/4 x 50 210 3) 250 3) 280 3) 310 3) 350 3) 400 3) 386 340 381 422 476 544 339 403 446 494 553 622 89 89.5 90 90.5 91.5 91.5 0.88 0.87 0.88 0.87 0.87 0.88 3/4 x 35 II 3/4 x 35 II 3/4 x 50 II 3/3 x 70 II 3/3 x 70 II 7 x 1 x 95 II 3/4 x 35 3/4 x 35 3/4 x 50 2 x 3 x 70 2 x 3 x 70 7 x 1 x 95 Motor size L 1~ mm 3~ Standard 1~ ¶ mm 3~ ¶ kg DN 100 ... 0.37 0.55 0.75 1.1 1.5 2.2 3.0 3.7 5.5 7.5 96 242 271 299 327 356 460 ------------- 223 242 271 299 327 356 423 552 704 780 8.3 9.6 10.8 13.5 14.4 18.0 ------------- 7.3 8.3 9.6 10.8 12.1 13.5 16.0 22.5 29.0 33.0 143 ------------------------------- 699 719 749 829 874 919 1009 1114 1214 1294 ------------------------------- 48 50 53 58 62 67 76 87 97 101 189 ------------------- 1140 1230 1340 1470 1560 1740 ------------------- 130 145 165 187 203 235 232 ---------------- 1419 1529 1659 1769 1919 ---------------- 260 295 340 390 428 282 ------------------- 1808 1908 2038 2108 2208 2308 ------------------- 535 575 645 680 720 780 UMA 150D ... UMA 150D UMA 150D UMA 150D UMA 150D UMA 150D UMA 150D UMA 150D UMA 150D UMA 150D UMA 150D UMA 200D ... UMA 200D UMA 200D UMA 200D UMA 200D UMA 200D UMA 200D UMA 250D ... UMA 250D UMA 250D UMA 250D UMA 250D UMA 250D UMA 300D ... UMA 300D UMA 300D UMA 300D UMA 300D UMA 300D UMA 300D 180/22 210/22 250/22 280/22 310/22 350/22 2) ∆-wiring of the 2 standard short cables for d.o.l. starting in the cable connector or in the control box. 3) Leistungsreduzierung für Y∆ -- Einschaltung Additional motor data: Frequency of starts . . . . . . . . . . . . . . . . . . . . . . . . . . 100 ≤ 20/h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 150D: ≤ 15/h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 200D/250D: ≤ 10/h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D ≤ 280/22: ≤ 10/h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D ≥ 310/22: ≤ 5/h Horizontal installation . . . . . . . . . . . . . . . . . . DN 100: all sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 150D: ≤ 30/21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 200D: ≤ 75/21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 250D: ≤ 160/21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D: ≤ 310/22 Motor cable: DN 100: L = 1.5 m (≤ 1.5 kW) / 2.5 m (> 1.5 kW), 1 x DN 150: L = 4 m, 1 x or 2 x UMA 150D: L = 4 m, 1 x or 1 x +1x UMA 200B: L = 6 m, 1 x +1x UMA 250B: L = 6 m, 1 x +1x or 1x +1x (≥ 35 mm2) UMA 300D: L = 10m, 1 x +1x or 2x (70 mm2) + 1 x (35 mm2) or 6x +1x (95 mm2) Other cables on request. 101 60 Hz Accessories Accessories Description Cable L Connector size 28 Plug Ident. No. Electric extension cable1), blue, rubber-sheathed cable for submerged operation in drinking water applications, ambient temperatures t ≤+50 oC. -- Cable kit, 4-core, round, only for pump sets with three-phase current (3~) motors, DN 100, L= 5m G RD GWT - J - 4G 1.5 (4 x 1.5 mm2) with earth conductor Consisting of: 1 plug, 10 m 2.5 m cable, 1 cable connector size 28 15 m and additional cable lengths. 20 m 25 m 30 m 35 m 40 m -- Cable kit, 4-core, round, G RD GWT - J 4G 1.5 (4 x 1.5 mm2) . . . per m with earth conductor 4G 2.5 (4 x 2.5 mm2) . . . . . . . . . . 4G 4.0 (4 x 4.0 mm2) . . . . . . . . . . 4G 6.0 (4 x 6.0 mm2) . . . . . . . . . . 4G 10 (4 x 10 mm2) . . . . . . . . . . . 4G 16 (4 x 16 mm2) . . . . . . . . . . 4G 25 (4 x 25 mm2) . . . . . . . . . . . 4G 35 (4 x 35 mm2) . . . . . . . . . . . 4G 50 (4 x 50 mm2) . . . . . . . . . . . 4G 70 (4 x 70 mm2) . . . . . . . . . . . -- Cable kit, 3-core, flat, G FL GWT - O 3 x 1.5 mm2 . . . . . . . . . . . per m without earth conductor 3 x 2.5 mm2 . . . . . . . . . . . . . . . . 3 x 4.0 mm2 . . . . . . . . . . . . . . . . . 3 x 6.0 mm2 . . . . . . . . . . . . . . . . . 3 x 10 mm2 . . . . . . . . . . . . . . . . . . 3 x 16 mm2 . . . . . . . . . . . . . . . . . . 3 x 25 mm2 . . . . . . . . . . . . . . . . . . 3 x 35 mm2 . . . . . . . . . . . . . . . . . . 3 x 50 mm2 . . . . . . . . . . . . . . . . . . 3 x 70 mm2 . . . . . . . . . . . . . . . . . . For selection see details and examples on pages 106 -- 109. Shielded Hydrofirm (T) cable Shielded Hydrofirm (T) cable Shielded Hydrofirm (T) cable S07BC4B--F 3x6/6KON S07BC4B--F 3x16/16KON S07BC4B--F 3x35+3G16/3 Standard cable connector with heat shrink tube, non--separable. -- 4 x 1.5 mm2 and 4 x 2.5 mm2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- As above, but connected and sealed at the factory . . . . . . . . . . . . . . . . . . . -- 4 x 4 mm2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- As above, but connected and sealed at the factory . . . . . . . . . . . . . . . . . . . Cable connector, separable, including sealing compound, size 25, only for pump sets with 3~ motors, DN 100, for connecting 1 extension cable to ... 1 motor lead . . . . . . . . . . . . . . . . . . . -- not including connection -- including connection Note: Can only be supplied together with the pump set. Separately available: -- Short cable: 1.5 m long, 4 x 1.5 mm2, with plug and cable joint 2.5 m long, 4 x 1.5 mm2, with plug and cable joint -- Cable joint: for 1 x 4 x 1.5 mm2, flat, or up to 1 x 4 x 4 mm2, round 1) For permissible cable lengths see pages 108 and 109. 102 ≈ kg 01 045 633 01 045 634 01 045 635 01 045 636 01 045 637 01 045 638 01 045 639 01 045 640 1.55 2.45 3.35 4.25 5.15 6.05 6.95 7.85 01 046 056 01 046 057 01 046 058 01 046 059 01 046 060 01 046 061 01 046 062 01 046 063 01 046 064 01 050 669 0.180 0.259 0.356 0.475 0.837 1.220 1.770 2.304 3.185 4.364 01 046 038 01 046 039 01 046 040 01 046 041 01 046 042 01 046 043 01 046 044 01 046 045 01 046 046 01 046 047 0.110 0.171 0.252 0.319 0.486 0.750 1.107 1.438 2.054 2.760 01 083 423 01 083 424 01 083 425 40 980 058 40 980 708 39 020 537 39 020 536 0.1 0.1 0.1 0.1 90 033 494 0.6 90 039 543 0.6 00 117 947 0.4 01 025 739 0.7 00 117 792 0.2 60 Hz Accessories Accessories Description Cable connector, non-separable, including sealing compound, for connecting 1 extension cable to 1 or 2 motor leads -- Size 28 for connecting 1 extension cable to ... 1 motor lead . . . . . . . . . . . . . . . . . -- supplied, but not connected -- connected and sealed at the factory . -- Size 35 for connecting 1 extension cable to ... 1 motor lead . . . . . . . . . . . . . . . . . -- supplied, but not connected -- connected and sealed at the factory -- Size 43 for connecting 1 extension cable to ... a) 1 motor lead . . . . . . . . . . . . . . -- supplied, but not connected -- connected and sealed at the factory b) 2 motor lead -- supplied, but not connected -- connected and sealed at the factory . Sizes 53 to 78 available on request. For selection see details and examples on page 110. 3300:236/2 Size 1 Ident. No. Size ≥ 2 Cable tie for fastening power supply cable to riser -- Size 1 (rubber strap / plastic studs), for cable sizes up to 1 FL 3 x 6 mm2 or 4 x 6 mm2 and 1 RD 4 x 6 mm2 . -- Sizes 2 -- 11 (metal strap / screw band with tension screw / rubber cable protector), for larger cross-sections up to 70 mm2 available on request Note: Cable ties for pump sets of material variants Standard B and Special on request. Note: Use 1 cable tie each per cable and per 3 m of riser pipe. For selection see details and examples on page 111. “UPA CONTROL” box 3~ / 400 V, for d.o.l. starting, temperature-compensated, insulating enclosure, with 4 PG cable glands for round cable, 3 immersion electrodes and integrated selector switch for “Dry running protection” or “Water level control” operation, as well as with thermal overcurrent relay with phase failure protection, for motor sizes ... 1~/230 V: 3~/400 V: -----0.37 kW -----0.55 kW + 0.75 kW -----1.10 kW + 1.50 kW 0.37 + 0.55 kW -----0.75 kW 2.20 kW 1.10 kW 3.00 kW + 3.7 kW 1.50 kW 2.2 kW 5.50 kW -----7.50 kW -----UMA 150D - 5/21 -----UMA 150D - 7/21 -----UMA 150D -- 9/21 Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode per m Automatic control units Cervomatic EDP with G 11/4’’ connection, for a max. flow rate of 12 m3/h, 3 Cervomatic EDP max. flow rate of 12 m /h, a max. operating pressure of 10 bar and a max. current rating of 10 A, for 1~ + 3~/ 220 to 240 V and 3~/ 380 to 415 V (with electric protection from 0 to 10 A, can be set in 0.5 A steps). Controlmatic E Controlmatic E with G 11/4’’ connection, for a max. flow rate of 10 m3/h, a max. operating pressure of 10 bar and a max. current rating of 10 A, for 1~ 220 to 240 V ≈ kg 95 005 106 0.45 90 049 385 0.45 90 049 397 0.5 90 049 387 0.5 90 049 399 90 049 389 90 049 400 90 049 390 0.55 0.55 0.55 0.55 90 006 993 0.04 ------ ------ 40 980 887 3.5 40 980 889 3.5 40 980 891 3.5 40 980 893 3.5 40 980 895 3.5 40 980 897 3.5 40 980 899 3.5 40 984 811 3.5 90 052 649 3.5 40 984 811 3.5 90 052 649 3.5 90 052 650 3.5 01 046 306 0.051 90 053 396 2.2 90 053 395 1.3 Dry running protection equipment for ... -- semi-automatic operation (1 relay, 1 pushbutton + 2 electrodes) . . . . . . . -- fully automatic operation (1 relay + 3 electrodes) . . . . . . . . . . . . . . . . . . . . 90 009 553 90 009 554 Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode 01 046 306 0.051 per m Pressure controller, (membrane-type), insulating enclosure . . . . . . . . . . . . . 1 -- 10 bar, with R 3/8 connection. 01 088 101 2.0 2.0 0.9 103 60 Hz Accessories Accessories Description Ident. No. ≈ kg 90 052 823 0.5 .......... .......... .......... .......... .......... 90 050 611 95 000 220 95 000 221 95 000 232 95 000 233 3.0 3.5 3.5 9.4 5.6 Pair of supporting and installation clamps for the following riser sizes ... incl. screws, bolts and nuts, -- R 11/4” / DN 32, L = 600 mm, F = 11.8 kN for installation / dismantling -- R 2’’ / DN 50, L = 600 mm, F = 17.5 kN ofvertical submersible --R 2 1/2’’ / DN 65 L = 600 mm, F = 17.5 kN pump sets in / -- R 3’’ / DN 80, L = 600 mm, F = 17.5 kN from wells, tanks, etc. -- R 4’’ / DN 100 L = 700 mm, F = 24.5 kN Material: Steel, painted. -- R 5’’ / DN 125 L = 800 mm, F = 31.0 kN -- R 6’’ / DN 150 L = 800 mm, F = 31.0 kN -- R 8’’ / DN 200 L = 900 mm, F = 108 kN 95 000 290 95 000 294 95 000 296 95 000 298 95 000 300 95 000 302 95 000 304 95 000 307 7.5 11.5 12.0 12.0 21.0 29.0 29.0 70.0 01 117 821 90 017 255 01 046 640 01 061 866 01 061 867 01 061 868 01 061 869 01 061 870 01 046 644 01 046 645 01 046 646 01 053 905 01 053 906 01 053 907 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 7.8 7.8 8.0 16.0 16.0 17.2 Adapter from threaded end G 11/4’’ to threaded end G 11/2’’ . . . . . . . . . . . Material: CrNiMo steel GR H Mode of supply: sealed and screwed tightly into the pump end. GP Adapter, threaded end G / Flange DN, PN 10/40 with 2 recesses on flange, 90o spacing (H = 120 mm, D = 155 mm) -- G 11/2’’ / DN 40, CrNi steel -- G 2’’ / DN 50, CrNi steel (H = 145 mm, D = 165 mm) -- G 2’’ / DN 50, CrNiMo steel (H = 145 mm, D = 165 mm) -- G 3’’ / DN 80, cast iron (H = 150 mm, D = 200 mm) -- G 3’’ / DN 80, CrNiMo steel (H = 180 mm, D = 200 mm) D DN H GP L Mode of supply: sealed and screwed tightly into the pump end. Other sizes and materials on request. 3409:3 Note: 2 pairs are required for installation / dismantling. Other sizes and materials on request. Set of bearing pedestals for horizontal installation consisting of 2 bearing pedestals, incl. screws, bolts and nuts. Material: CrNi steel 1.4301 -- UPA 150C pumps with UMA 150D motors . . . . . Galvanized steel -- UPA 200 pumps with UMA 150D motors . . . . . . . S235 JRG2+Z -- UPA 200 pumps with UMA 200D motors . . . . . . . CrNi steel 1.4301 -- UPA 200B pumps with UMA 150D motors . . . . . -- UPA 200B pumps with UMA 200D motors . . . . . -- UPA 250C pumps with UMA 150D motors . . . . . -- UPA 250C pumps with UMA 200D motors . . . . . -- UPA 250C pumps with UMA 250D motors . . . . . Galvanized steel -- UPA 300--65 pumps with UMA 200D motors . . . S235 JRG2+Z -- UPA 300--94 pumps with UMA 200D motors . . . -- UPA 350 pumps with UMA 200D motors . . . . . . . -- UPA 300--65 pumps with UMA 250D motors . . . -- UPA 300--94 pumps with UMA 250D motors . . . -- UPA 350 pumps with UMA 250D motors . . . . . . . Note: Screws, bolts and nuts for fixing the bearing pedestals on the foundation are to be supplied by the customer / end user. Other sizes and materials on request. Pt 100 temperature monitoring equipment for use in submersible motors to protect the windings from overheating. Consisting of -- Resistance thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- Control current line, blue, round 4 x 0.5 mm2 . . . . . . . . . . . . . . . . . . . per m -- Display / control box (supply voltage U = 110/220V/240V) . . . . . . . . . . . . . . Note: Motors with Pt 100 are manufactured to order! Centralizer for submersible motors for UMA 150D and UMA 200D motors in wells up to DN 350, plastic (PE) bis DN 250 bis DN 300 bis DN 350 Other sizes and materials on request. 104 ----------01 049 403 0.085 00 137 543 0.320 90 047 662 90 047 663 90 047 664 ---------------- 60 Hz Accessories Accessories Description Cooling, suction and pressure shroud for vertical and horizontal installation Galvanized steel and CrNiMo steel material variants on request. Stainless steel immersion electrodes Stainless steel wire rope for S 100D 3 electrodes 1 electrode 15 m 30 m Lightning protection with earthing terminal for -- 3~/ 400 V (supplied separately) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cable tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . per unit Ident. No. ≈ kg ------ ------ 40 980 055 0.3 40 980 056 0.1 42 200 727 0.7 42 204 021 1.2 00 533 299 0.28 40 980 709 105 60 Hz Accessories Electric Cable for Use in Drinking Water Applications Applications For use in water as standard short submersible motor cable (3- + 4-core, flat) and for use in air as extension cable from motor cable to control box / mains (3-core, flat and 4-core, round). Application Limits Rated voltage: -- UN ≤ 1000 V for ex. in wells, -- UN ≤ 750 V in swimming pools. Ambient temperature . . . . . t ≤ +50 oC. Immersion depth . . . . . . . . . ≤ 500 m. Description / Design a) Flat cables: b) Round cables: 1) 3 cores 2) 4 cores 1) As a standard, for use as short motor 2) For use as earth conductor only. 1 core 4 cores cable only. 3-/4-core rubber-sheathed cable. Consisting of finely stranded bare copper conductors, core insulation and outer sheath made of special rubber compound on EPR basis (ethylene propylene rubber), blue. With BAM 1) certificate, i.e. suitable for permanent use in drinking water applications. 1) German Federal Institute for Materials Research Designation (Example) Flat cable: ZN 1391 - G Factory standard Insulation: rubber FL: flat + RD: round For drinking water Earth conductor: “O = without, “- J” = with Cores (O: “3 x 25”, J: “4 G 25”) Materials FL GWT -J 4G25 - Cu-Rubber Dimensions + Weights Cross-section Type in mm2 1.5 2.5 4 6 10 16 25 35 50 70 mm 5.2 + 1 6.1 + 1.5 7.0 + 2 7.6 + 2.2 9.3 + 2.2 11.2 + 2.3 13.0 + 2.5 14.6 + 2.9 17.0 + 3 19.3 + 2.7 $ mm 11.0 + 2 13.2 + 2.3 15.5 + 3.5 17.4 + 3.6 21.5 + 3.5 26.7 + 4.3 31.6 + 3.9 35.5 + 5 42.1 + 4.9 48.4 + 3.6 ↕ 106 q m kg/m 0.110 0.171 0.252 0.319 0.486 0.750 1.107 1.438 2.054 2.760 ↕ mm 5.2 + 1 6.1 + 1.5 ------ 7.6 + 2.2 9.3 + 2.2 11.2 + 2.3 13.0 + 2.5 ------ ------ ------ $ mm 14.5 + 2.7 17.5 + 2.5 ------ 23.5 + 3 29.0 + 3.5 35.0 + 2.4 41.5 + 4.5 ------ ------ ------ m kg/m 0.165 0.237 ------ 0.440 0.704 1.026 1.457 ------ ------ ------ ∅ mm 5.3 + 1.1 ------ ------ ------ ------ ------ ------ 13.8 + 3.6 16 + 3.8 ------ m kg/m 0.051 ------ ------ ------ ------ ------ ------ 0.499 0.699 ------ ∅ mm 10.0 + 2 12.0 + 1.9 13.9 + 2 15.7 + 2.1 21.1 + 2.1 24.5 + 4.3 29.7 + 4.3 33.3 + 5.5 39.0 + 5.6 44.2 + 5.8 m kg/m 0.180 0.259 0.356 0.475 0.837 1.220 1.770 2.304 3.185 4.364 60 Hz Accessories Maximum Permissible Rated Motor Current Imax a) Ambient temperature t ≤ + 30 oC! Imax in A for cross-section of ... mm2 Starting Used as ... 1.5 2.5 4 6 10 16 25 35 50 70 D.o.l. (1 cable or 2 cables in parallel 1)) Short motor cable 2) 29 38 52 67 94 125 166 205 256 316 Extension cable 3) 23 30 41 53 74 99 131 162 202 250 Y-∆ (2 cables) Short motor cable 2) 50 66 90 116 163 217 288 355 443 547 Extension cable 3) 40 52 71 92 128 171 227 280 350 433 1) For 2 cables II: I ≤ 2 x I N max. 2) I max for submerged use, laid in free water or 3) I max for use in open air, laid along a surface. closely along the pump. For other conditions see DIN VDE 0298. For other conditions see DIN VDE 0298. b) Ambient temperature t > + 30 oC! If t > + 30 oC, the current-carrying capacity of the cables is lower. Imax indicated under a) must be de-rated by a factor fT: t in °C fT [----] ≤ 35 ≤ 40 ≤ 45 ≤ 50 0.96 0.91 0.87 0.82 Voltage Drop ∆U Along Extension Cable When calculating the required copper conductor cross-section q, not only IN, but also the voltage drop ∆U along the cable length L (distance from motor to control box) must be taken into account. Proper functioning of our submersible motors requires that ∆U ≤ 3 % of the supply voltage U! If ∆U > 3 %, a larger cable must be used. The voltage drop is calculated using the following equations: a) D.o.l. starting / autotransformer ... -- 1 cable: 3 µ ... ∆U = 3.1 x L x IN x cos phi q x U [%] 1 µ ... ∆U = 3.6 x L x IN x cos phi q x U [%] [%] 1 µ ... ∆U = 1.8 x L x IN x cos phi q x U [%] -- 2 cables in parallel (II): 3 µ ... ∆U = 1.55 x L x IN x cos phi q x U b) Y-∆ starting (2 cables) ... ∆U = 2.1 x L x IN x cos phi q x U [%] Power Loss ∆P Along the Extension Cable ∆P = where ... L IN cos phi q U ∆U (cos phi) 2 [%] = single cable length [m] = rated current [A] = power factor at 4/4 load = copper conductor cross-section [mm2] = supply voltage [V] 107 60 Hz Accessories Permissible Cable Lengths L D.o.l. Starting (1 cable or 2 cables in parallel) 400 300 70 mm2 Imax = 250 A 50 mm2 Imax = 202 A 200 35 mm2 Imax = 162 A 25 mm2 Imax = 131 A 16 mm2 Imax = 99 A 100 90 80 70 Imax = 74 A 10 mm2 → 60 6 mm2 Imax = 53 A 50 4.0 mm2 Imax = 41 A 40 ↓ ↓ ↓ ↓ 2.5 mm2 Imax = 30 A 30 U = 460 V ∆U = 3 % t ≤ + 30 oC in air laid along a surface! 1.5 mm2 Imax = 23 A 20 IN [A] 10 9 8 7 6 5 4 3 2 1 10 20 30 40 50 60 70 80 90100 L [m] 200 300 400 500 Example: a) IN = 68 A, 1 x 16 mm2 , ∆U ≤ 3 % → L ≤ 120 m! b) IN = 68 A, 1 x 25 mm2 , ∆U ≤ 3 % → L ≤ 185 m! For supply voltages other than 460 V, the cable lengths must be calculated as follows, for ex. ... U1 = 460 V, L1 = 120 m, U2 = 380 V → L2 = (U2 : U1) x L1, L2 = (380 V : 460 V) x 120 m = 99 m! For parallel cables the value is doubled to obtain the permissible length. 108 60 Hz Accessories Permissible Cable Lengths L Y-∆ Starting (2 cables) 400 300 Imax = 350 A 50 Imax = 280 A 35 mm2 Imax = 227 A 200 16 mm2 Imax = 128 A 10 mm2 6 mm2 Imax = 92 A 4,0 mm2 Imax = 71 A 60 Imax = 52 A 50 2,5 mm2 1,5 mm2 Imax = 40 A 40 30 mm2 25 mm2 Imax = 171 A 100 90 80 70 U = 460 V ∆U = 3 % t ≤ + 30 oC in air laid along a surface! 70 mm2 Imax = 433 A → 20 IN # # # # [A] 10 9 8 7 6 5 4 3 2 1 10 20 30 40 50 60 70 80 90100 L [m] 200 300 400 500 Example: a) IN = 27 A, 2 x 6 mm2, ∆U ≤ 3 % → L ≤ 165 m! b) IN = 27 A, 2 x 10 mm2 , ∆U ≤ 3 % → L ≤ 260 m! For supply voltages other than 400 V, the cable lengths must be calculated as follows, for ex. ... U1 = 460 V, L1 = 165 m, U2 = 380 V, → L2 = (U2 : U1) x L1, L2 = (380 V : 460 V) x 165 m = 136 m! 109 60 Hz Accessories Connector for Electric Cable Applications Used to provide a sealed, water--tight connection between electric extension cable and short submersible motor cable. Supply voltage . . . . . . . . . . . U ≤ 750 V. Ambient temperature . . . . . t ≤ +50 oC. Immersion depth . . . . . . . . . ≤ 500 m. Selection Criteria Type, number and dimensions of the standard short motor cable and the extension cable. Selection Table The table below only shows the electric cables on stock. Connectors for other cables on request. Extension cable ... mm2 Standard short motor cable mm2 1.5 1.5 / 2.5 28 28 28 35 35 4 6 ------- 35 ---- 35 35 35 35 35 35 10 ---- ---- ---- 43 16 25 ------- ------- ------- ------- 35 50 ------- ------- ------- 70 ---- ---- ---- 2.5 4 6 10 16 25 35 50 70 43 53 53 ---- ---- 43 43/29 f 53 53/29 f 53 53/39 f ------- ------- 43/29 f 43/29 f 53/29 f 53/39 f ---- ---- ------- 53 ---- 53 66 53 66 66 66 66 66 ------- ------- ------- ------- 66 66 66 66 66 66 ---- ---- ---- ---- ---- ---- 66 Cable connector size ... 1) 1.5 / 2.5 4 28 ---- 28 35 28 35 35 35 35 35 43 43 53 53 53 53 ------- ------- 6 10 ------- ------- 35 ---- 35 43 35 43 43 43 53 53 53 53 ------- ------- 16 ---- ---- ---- ---- ---- 53 53 53 66 66 25 ---- ---- ---- ---- ---- ---- 66 66 66 66 + or 1) + 1.5 28 28 28 35 35 ---- ---- ---- ---- ---- 2.5 4 35 ---- 35 ---- 35 35 35 35 35 35 ---43 ------- ------- ------- ------- 6 ---- ---- ---- 43 43 43 53 53 66 66 10 16 ------- ------- ------- 66 ---- 66 ---- 66 66 66 66 66 66 66 66 66 66 25 ---- ---- ---- ---- ---- ---- 78 78 78 ---- 1) 1.5 / 2.5 / 4 28 28 28 28 35 43 ---- ---- ---- ---- 6 28 28 28 28 35 43 53 53 ---- ---- 10 16 ------- ------- 35 ---- 35 ---- 35 43 43 43 53 53 53 53 ---66 ---66 25 35 ------- ------- ------- ------- ------- 53 ---- 53 ---- 53 53 66 66 78 78 50 ---- ---- ---- ---- ---- ---- ---- ---- 66 78 70 ---- ---- ---- ---- ---- ---- ---- ---- ---- 78 2) 1) 2) 35 ---- ---- ---- ---- ---- ---- ---- 35 ---- ---- 50 70 ------- ------- ------- ------- ------- ------- ------- ------- 35 ---- ---35 On stock up to 50 mm2 only. Legend: 110 2) For use as earth conductor only. = G FL GWT -O 3 x ... = G FL GWT -J 4G ... = G RD GWT -O 1 G (earth conductor for UMA 300C) = G RD GWT -J 4G 60 Hz Accessories Cable Tie for Electric Cable Applications Securing electric cable at the riser / discharge pipe. Suitable for use in normal or slightly aggressive water. Models for use in more aggressive wasser (for ex. seawater) available on request. Selection Criteria Type, number and size of the electric cable, as well as nominal diameter and length of the riser / discharge pipe. Selection Table Electric cable Number x core dia. in mm2 Type Flat Round 1) Tie size m 1) Required length of strap L per cable tie in ¶ ... mm for risers G .../DN ... ---- ¶ kg 11/4’’ / 32 11/2’’ / 40 2’’/ 50 21/2’’/ 65 3’’/ 80 4’’/ 100 5’’/ 125 6’’/ 150 7’’/ 175 8’’/ 200 10’’ 250 12’’ 300 14’’ 350 16’’ 400 3 x 1.5 to 3 x 6.0 4 x 1.5 to 4 x 6.0 1 ---- 270 280 320 360 400 450 500 600 -------- -------- -------- -------- -------- -------- 3 x 10 to 3 x 70 4 x 10 to 4 x 70 11 0.01 ---- ---- 350 400 450 550 650 800 950 1100 1300 1500 1700 1900 3 x 1.5 to 3 x 6.0 4 x 1.5 to 4 x 6.0 1 ---- 270 280 320 360 400 450 500 600 ------ ------ ------ ------ ------ ------ 3 x 10 4 x 10 2 0.08 ---- ---- 350 400 450 550 650 800 950 1100 1300 1500 1700 1900 3 x 16 3 x 25 4 x 16 3a 0.19 ------ ------ 350 400 450 550 650 800 950 1100 1300 1500 1700 1900 3 x 35 3 x 50 4 x 25 4 x 35 3 0.19 ------ ------ ------ 450 500 600 700 850 1000 1150 1350 1550 1750 1950 3 x 70 4 x 50 3b 0.19 ------ ------ ------ 450 500 600 700 850 1000 1150 1350 1550 1750 1950 3 x 95 4 x 70 4 x 95 4 0.55 ------ ------ ------ ------ ------ 650 750 900 1050 1200 1400 1600 1800 2000 3 cables 1 x 50 7 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050 3 cables 1 x 70 8 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050 3 cables 1 x 95 6 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050 3 cables 1 x 120 3 cables 1 x 150 9 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050 Cable protector (Sizes 11, 2 to 9). Design Size 11: Size 1: b a d Sizes 2, 3, 3a, 3b, 4: Sizes 6, 7, 8, 9: d b c e c a a= b= c= d= Riser Electric cable Rubber strap Plastic stud (2 pcs/cable tie) a = Riser b = Electric cable c = Metal strap d = Cable protector e = Screw band with tension screw (re-usable) Note: -- Use 1 cable tie each per cable and per 3 m of riser pipe. -- If an extension cable with a larger diameter is connected to the standard short motor cable, the cable tie size required for the larger cable is to be used along the entire cable length. 111 Submersible borehole pumps 60 Hz Flow Velocity v Past the UMA Submersible Motor Depending on the general installation arrangement (i.e. depending, for example, on the ratio of outside motor diameter to inside well or shroud diameter, etc.) a distinction must be made between the following cases ... a) v = 0 m/s ... this applies, for example, when the pump set is installed in a deep well below the well screen / filter, in a pump sump, tank or other reservoir, etc. Caution: At v = 0 m/s, UMA 250D motors can only be operated at reduced rated power. b) v ≥ 0.2 m/s ... this describes with adequate accuracy the case when the pump set is, for example, installed in a deep well above the well screen / filter, etc. In borderline cases (for ex. if the inside well diameter is very large compared with the outside motor diameter) the diagram below can be used to double-check the data. c) v ≥ 0.5 m/s ... In this case it must always be checked, using the diagram below, whether the installation dimensions (i.e. the ratio of outside motor diameter to inside well diameter) are adequate to ensure a minimum flow velocity past the motor of v ≥ 0.5 m/s. If not, use a special cooling shroud. How to read the diagram: The requirement for a “flow velocity past the motor of v ≥ 0.2 or 0.5 m/s” is met, if the point of intersection of the capacity Q and the inside well or shroud diameter DN is located on or to the right of the curve applicable to the submersible motor used. Max. permissible well diameter for compliance with required flow velocity past the motor 1400 V >= 0.2 m/s ∅ 1200 [mm] 1000 V >= 0.5 m/s 800 DN 100V ≥ 0.1 600 UMA 300D UMA 250D UMA 200D UMA 150D DN 100 400 200 0 0 100 200 300 400 500 600 700 800 900 Q [m#/h] Example: Given: UPA 300 - 65/4 + UMA 250D 160/21 and v ≥ 0.5 m/s. Found: For Q = 250 m3/h (¶ Qopt) the following applies: ⇒ DN ≤ 700 mm. This means that the requirement for v ≥ 0.5 m/s is met, if the pump set is, for example, installed in a well or cooling shroud of DN ≤ 700 mm or ≤ 28 inches. 112 60 Hz Submersible borehole pumps 113 3400.51/2--10 06/2008 Subject to technical modification without prior noice. 60 Hz Submersible Borehole Pumps