Section F – Air Atomizing Spray Nozzles
Transcription
Section F – Air Atomizing Spray Nozzles
Section F – Air Atomizing Spray Nozzles Overview Air Atomizing Spray Nozzles Table of Contents If your application requires air atomizing nozzles, you’ll find information on the largest selection in the industry available in this section. Choose from dozens of nozzle bodies, assemblies and spray set-ups to get the precise performance you require. Basic Information Set-ups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F3 Air atomizing nozzles require a single air source for the atomizing air. Some versions, equipped with a cylinder for automatic operation or clean-out and shut-off needles, may require an additional air line. Fluid lines are required for all models. The fluid line can be pressurized or supplied using a siphon- or gravityfed configuration. It is recommended that air and fluid lines are equipped with the proper filters, regulators and valves. Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F4 Air atomizing nozzles require spray set-ups. Each set-up consists of an air cap and fluid cap and some may also include O-rings and retainer caps. You can select from a wide assortment of capacities, spray patterns and pressure- or siphon-fed set-ups. Pressure Spray Set-ups, Internal Mix, High Transfer Efficiency (HTE). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F19 • Product Range: – 1/8J and 1/4J Series nozzles are available in many configurations and operate at standard flow rates. Ranges from: 0.55 to 58.1 gph at 40 psi (2.08 to 220 l/h at 2.8 bar). 1/8JJ Compact Series 1/8J and 1/4J Series Overview/Nozzle Bodies/Nozzle Assemblies. . . . . . . . . . . . . . . . . . . F5 Pressure Spray Set-ups, Internal Mix. . . . . . . . . . . . . . . . . . . . . . . . . F9 Pressure Spray Set-ups, External Mix. . . . . . . . . . . . . . . . . . . . . . . . F15 Siphon/Gravity-Fed Spray Set-ups, External Mix. . . . . . . . . . . . . . . F23 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F25 Pressure Spray Set-ups, Internal Mix. . . . . . . . . . . . . . . . . . . . . . . . F27 – Variable spray nozzles provide independent control of liquid, atomizing air and fan air pressure for fine tuning of flow rate, drop size, spray distribution and coverage. Pressure Spray Set-ups, External Mix, High Capacity. . . . . . . . . . F31 Pressure Spray Set-ups, Internal Mix, Air Efficient . . . . . . . . . . . . F33 – 1/2J Series nozzles offer the same features and benefits as 1/8J and 1/4J Series but operate at higher capacities. Ranges from: 22.2 to 222 gph at 40 psi (84 to 840 l/h at 2.8 bar). Siphon/Gravity-Fed Spray Set-ups, External Mix. . . . . . . . . . . . . . . F34 Variable Spray Series – 1J Series nozzles offer the highest flow rates available. Ranges from: 120 to 906 gph at 40 psi (454 to 3430 l/h at 2.8 bar). Variable Spray Nozzles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F36 Pressure Spray Set-ups, External Mix. . . . . . . . . . . . . . . . . . . . . . . . F38 Additional information can be found in Section G, Automatic Spray Nozzles and in Section K, Special Purpose Spray Nozzles. 1/2J Series Nozzle Bodies/Nozzle Assemblies. . . . . . . . . . . . . . . . . . . . . . . . . . . F43 Pressure Spray Set-ups, Internal Mix. . . . . . . . . . . . . . . . . . . . . . . . F45 Pressure Spray Set-ups, External Mix. . . . . . . . . . . . . . . . . . . . . . . . F47 Siphon/Gravity-Fed Spray Set-ups, External Mix. . . . . . . . . . . . . . . F49 1J Series Nozzle Bodies/Nozzle Assemblies. . . . . . . . . . . . . . . . . . . . . . . . . . . F50 Pressure Spray Set-ups, Internal Mix. . . . . . . . . . . . . . . . . . . . . . . . F51 Pressure Spray Set-ups, External Mix. . . . . . . . . . . . . . . . . . . . . . . . F53 Siphon/Gravity-Fed Spray Set-ups, External Mix. . . . . . . . . . . . . . . F53 Special Purpose Air atomizing caps AirJet® Fogger Spray Nozzles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F54 DripSafe™ AirJet Fogger Spray Nozzles. . . . . . . . . . . . . . . . . . . . . . F56 Humidification Spray Nozzles and Units. . . . . . . . . . . . . . . . . . . . . . F58 Humidification System Components. . . . . . . . . . . . . . . . . . . . . . . . . F60 Air Atomizing Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F61 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F1 Air Atomizing Nozzles Nozzle Bodies/Nozzle Assemblies. . . . . . . . . . . . . . . . . . . . . . . . . . . F26 Air Atomizing Nozzles Air Atomizing Spray Nozzles Optimization Tips • Reduce installation time by using split-eyelet connectors on both the air and fluid lines. Split-eyelet connectors only require a hole drilled into the pipe, eliminating the need for cutting, threading and brazing operations. • To eliminate the unintentional release of non-atomized liquid, use a check valve to shut down liquid flow if no air pressure is detected. • Use air atomizing nozzles with clean-out needles to eliminate clogging and ensure optimum performance. • Use strainers and air filters to ensure optimum performance. • If positive shut-off is required, use Drip Free™ set-ups with JAU nozzles. • Use a heat jacket with VAU/VMAU variable spray nozzles to keep viscous liquids warm and transferable. • When adjusting air pressure with internal mix nozzles, do not exceed recommended values as it may result in choking liquid flow. Increasing liquid flow can also choke air flow. AutoJet Spray Controllers and Systems • For optimal control of your air atomizing spray system, the use of an AutoJet® Spray System helps conserve liquid usage and reduces scrap by monitoring and automatically adjusting spray pattern, flow rate, drop size, liquid pressure and atomizing air pressure. Air atomizing nozzles with clean-out needles Heat jackets Spray nozzles Hot fluid flow channel Cut out view of heat jacket showing unique flow channel Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F2 Set-ups, Basic Information • Liquid can be supplied to the nozzle under pressure or it can be supplied through a liquid siphon or gravity-feed. Pressure Spray Set-ups Siphon/Gravity-Fed Spray Set-ups • Liquid is supplied to the nozzle under pressure. • Liquid is supplied via liquid siphon or is gravity-fed. • Air and liquid can be externally or internally mixed to produce a completely atomized spray. • Designed to draw liquid through the feed line into the air flow where it is atomized. Air pressure regulator with gauge – 1/8J and 1/4J Series Pages F23 – F24 – Compact 1/8JJ Series Pages F34 – F35 – 1/2J Series Page 49 – 1J Series Page 53 Air Atomizing Nozzles – 1/8J and 1/4J Series Pages F5 – F18 – 1/2J Series Pages F43 – F48 – 1J Series Pages F50 – F52 – Compact 1/8JJ Series Pages F25 – F33 – Variable 1/8VAA Series Pages F36 – F42 • New High Transfer Efficiency (HTE) external mix air atomizing set-ups recently introduced for 1/4J Series. – Pages F19 – F22 Air shut-off valve Air shut-off valve Air inlet Air pressure regulator with gauge Air filter 1/4JN air atomizing nozzle Air filter 1/4JN air atomizing nozzle Liquid inlet Siphon tube Liquid shut-off valve Liquid pressure regulator with gauge Air inlet Siphon height Liquid container TW liquid strainer Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F3 Air Atomizing Nozzles Features, Basic Information Spray Set-up Features Atomization Control Features • Each series is available with a pressure spray set-up or siphon spray set-up. • Achieved by adjusting the air and liquid pressure in the spray set-up. • Each set-up provides a specific spray pattern with a specific capacity and spray coverage range performance. • Obtaining finer atomization is accomplished by increasing the air pressure and/or lowering the liquid pressure, resulting in a high ratio of air flow rate to liquid flow rate. • Spray set-ups are interchangeable for each nozzle series. – Round spray: Extended full cone round spray pattern. – Wide angle round spray: Hollow cone-type, wide angle round spray pattern. – 360° circular spray: Hollow cone-type 360° circular spray pattern. – Flat spray: Extended flat or sheet-type spray pattern. – Deflected flat spray: Extended flat or sheet-type spray diverted away from the axis of the inlet connection. • Each spray set-up consists of an air cap and fluid cap. • For more information request Data Sheets 10616 and 10616-1. External mix with pressure set-ups: Flat and round spray patterns. Air cap Fluid cap Internal Mix Features External Mix Features • Liquid and air are mixed internally to produce a completely atomized spray. • Liquid and air streams are mixed outside of the nozzle. • Liquid and gas streams are not independent and a change in air flow will affect the liquid flow. • Effective for higher viscosity liquids and abrasive suspensions. • Air and liquid flow can be controlled independently. • External mix can use siphon set-ups or pressure set-ups. • Internal mix uses pressure set-ups and is available with the following spray patterns: – 360° circular spray. – Flat spray. – Deflected flat spray. – Round spray. – Elliptical spray. – Wide angle round spray. Internal mix with pressure set-ups: Round spray patterns • When a siphon set-up is used, a round spray pattern is produced. • When a pressure set-up is used, a flat spray pattern is produced. External mix with siphon set-ups: Round spray patterns Internal mix with pressure set-ups: Flat spray patterns External mix with pressure set-ups: Flat spray patterns Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F4 Overview/Nozzle Bodies/Nozzle Assemblies, 1/8J and 1/4J Series 1/8J and 1/4J Series air atomizing Spray set-up for HTE 1/8J, 1/4J Plug CP1159 2 3 Spray set-up 1/8JN, 1/4JN 1 1/8JCO, 1/4JCO 11005–1/8J, 11005–1/4J 1/4JAU – Drip Free Shut-off needle assembly 12810 4 2 3 1. Retainer ring CP1158 2. Air cap 3. Fluid cap 4. Fluid cap gasket CP3612 5. Nozzle body CP1151 6. Back seal gasket CP10439 6 5 Clean-out needle assembly 11829 Shut-off/clean-out needle assembly 11140 Air Atomizing Nozzles 1 Spray set-up for Drip Free™ 1 2 3 4 Shut-off/clean-out needle assembly Features and Benefits • The basic J Series nozzle assembly consists of a body and a spray set-up. • JN features a manual shut-off needle that enables the flow of liquid to the nozzle to be stopped. • Various assemblies can be added to provide shut-off and clean-out functions. • JCO features a clean-out needle that is activated manually. – The needle slides through the liquid orifice to clear obstructions. • 1/8J and 1/4J bodies have liquid and air feeds at opposite ends of the body. – Bodies are provided with a removable plug so other needle assemblies may be added in the future. – Ideal for intermittent spraying applications when liquid can dry in the orifice between uses. • 11005 combines the features of JN and JCO offering a combination shut-off/clean-out needle. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F5 Air Atomizing Nozzles Nozzle Bodies/Nozzle Assemblies, 1/8J and 1/4J Series 1/8J, 1/4J 1/8JN, 1/4JN 1/8" and 1/4" NPT or BSPT 1/8JCO, 1/4JCO 11005-1/8J, 1/4J 1/8" or 1/4" NPT or BSPT with clean-out needle 1/8" or 1/4" NPT or BSPT with shut-off/clean-out needle 1/8" and 1/4" NPT or BSPT with shut-off needle Optimization Tips See Also • See page F2 for optimization tips. • Accessories – Air line filters Materials Material Nozzle Type Material Code J JN JCO 11005 – Air pressure regulators – Solenoid valves – Liquid pressure regulators – Strainers Complete Nozzle Assembly Nozzle Body* Spray Set-up Only Spray Set-up Spray Set-up 1/4 JN – SS + SU11DF – SS (none) l l l l 303 Stainless Steel SS l l l l Lucite®* LUC l l l l l l Inlet Conn. Nozzle Body Assembly Type Material Code Spray Set-up No. Material Code *Includes retainer and gasket. Spray Set-ups Lucite* – Pressure gauges Ordering Info Nozzle Bodies Electroless Nickelplated Brass http:// BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. LUC l Electroless Nickelplated Brass Air Cap and 303 Stainless Steel Fluid Cap SSBR l l l l 303 Stainless Steel SS l l l l To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 2050-SS. SU11DF – SS l l Spray Set-up No. Material Code To order spray set-up only, use spray set-up number and material code: SU11DF-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: 67147-SS. To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1/4JN-SS. *May not be available for all spray set-ups listed. Other materials available upon request. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F6 Nozzle Bodies/Nozzle Assemblies, 1/8J and 1/4J Series Features and Benefits • 1/4JF features a built-in liquid strainer. • The 7545 multiple swivel spray assembly features each spray set-up mounted on its own swivel body. – One or two bodies may be used and each can be rotated 360° to the desired position. • 1/4JFN features built-in liquid strainer and liquid shut-off needle. • JBC features the center lines of the air and liquid inlet entering in the back of the nozzle and parallel to the spray projection axis. – Swivel bodies are locked in place by a stainless steel lock screw that runs vertical through the assembly. • JACN features air and liquid inlet connections entering the nozzle at 90° to spray projection axis and a shut-off needle. • 1/8-2JAC dual spray assembly features two opposing spray set-ups with the air and liquid inlet connections perpendicular to the spray axis. • 6552-1/8JAC miniature assembly body is only 1/2" (13 mm) thick with a 1-5/32" (29 mm) by 1-1/4" (32 mm) rectangular face. – The tip of the nozzle projects from the face a maximum of 1-3/16" (30 mm) depending upon the spray set-up used. • 1/4JBCJ features a steam jacket around the nozzle body for spraying liquids that are too viscous to spray at room temperature. With Strainer Top Inlet 1/4JF and 1/4JFN 1/4" NPT or BSPT (F) air inlet connection 1/8" NPT or BSPT (F) liquid inlet connection Swivel Back Connect 1/8JBC and 1/4JBC 1/8" or 1/4" NPT or BSPT (F) inlet connection 1/8JAC, 1/8JACN 1/4JAC, 1/4JACN 1/8" or 1/4" NPT or BSPT (F) inlet connection Top Inlet 1/8-2JAC 1/8" NPT or BSPT (F) inlet connection Optimization Tips Miniature • See page F2 for optimization tips. See Also • Accessories – Air line filters 7545 1/8" NPT or BSPT (F) air and liquid inlet connection – Air pressure regulators 6552-1/8JAC 1/8" NPT or BSPT (F) air and liquid inlet connection http:// – Pressure gauges – Solenoid valves – Liquid pressure regulators – Strainers • For JBC, request Data Sheets 4921, 6885 and 6185 • For JAC and JACN, request Data Sheets 4922 and 4922-1 Steam Jacket • For 1/8-2JAC dual spray assembly, request Data Sheet 6497 • For 7545 multiple swivel spray assembly, request Data Sheet 7545 • For 6552-1/8JAC, request Data Sheet 6552 • For 1/4JBCJ, request Data Sheets 4610 and 6331 1/4JBCJ 1/4" NPT or BSPT (F) inlet/outlet connection Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F7 Air Atomizing Nozzles • JAC features air and liquid inlet connections entering the nozzle at 90° to spray projection axis. Air Atomizing Nozzles Nozzle Bodies/Nozzle Assemblies, 1/8J and 1/4J Series Features and Benefits • 8650 multiple spray assembly (cluster type) features five spray set-ups located on the faces of the assembly or four set-ups located on the side faces. • 1/4JDLN and 1/4JDLCO feature a screw mount with 9/32" (7 mm) diameter mounting holes. – Standard 1/4" (6 mm) screws hold the body to the wall with a gasket providing the seal. • 2J is a dual spray assembly with opposing spray set-ups perpendicular to opposing air and liquid inlets. – The 1/4JDLN features a shut-off needle and the 1/4JDLCO features a clean-out needle. • 20470 Series hand-held air atomizing spray guns feature lightweight aluminum construction and a comfortable, easy-to-operate design. • Thin wall adapters add an adapter locknut and gasket to CP3376 thick wall adapters to provide secure mounting in thin walls and include CP6378 locknut and CP2804-3 gasket. • Thick wall adapters replace retainer rings on nozzle assemblies and fit into threaded wall openings, holding the nozzle securely in place. Cluster Type 8650 1/4" NPT or BSPT (F) air and liquid inlet connection – Extensions are available in up to 36" (91 cm) lengths. Twin Spray Thin Walls 2J 1/4" NPT or BSPT (F) inlet connection Available for 1/8J and 1/4J assemblies Thick Walls 1/8J and 1/4J with 3/4" NPT or BSPT (M) adapter connection Optimization Tips Screw Mount • See page F2 for optimization tips. See Also 1/4" NPT or BSPT (F) air and liquid inlet connection • Accessories – Air line filters – Air pressure regulators 20470 http:// – Pressure gauges – Solenoid valves – Liquid pressure regulators – Strainers • For 8650 multiple spray assembly, request Data Sheet 8650 • For 2J, request Data Sheets 5356 and 6530 • For thin wall adapters , request Data Sheet 3378 • For thick wall adapters, request Data Sheets 3378, 7003 and 7323 Hand-held spray gun 1/4" NPT or BSPT (F) inlet connection • For 1/4JDLN and 1/4JDLCO, request Data Sheet 7690 • For 20470 Series hand-held air atomizing spray guns, request Data Sheets 20470J, 20470JN, 20470JMCO, 20470JN-1, 20470JJ, 20470JJN and 20470JJNTK Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F8 Pressure Spray Set-ups, Internal Mix, 1/8J and 1/4J Series Features and Benefits Air Caps • For round spray pattern, angle “A” is maintained throughout distance “B”. Beyond “B”, the spray becomes turbulent and will project out to distance “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Round spray air caps produce a narrow, full cone round spray pattern Fluid cap Air cap Round spray pattern A B D 1158 retainer ring 3612 gasket Air Atomizing Nozzles 1158 retainer ring and 3612 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Round Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SU11 Fluid Cap 2050 + Air Cap 67147 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Liquid* Spray Angle A (°) B (in.) D (ft.) 12 10 13 12 9 24 20 13 13 10 14 11 Air* Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. 10.0 .66 .55 14.0 1.50 .40 24 1.68 .56 32 1.86 .68 50 2.28 .98 12.0 .48 .67 18.0 1.23 .50 28 1.44 .63 36 1.62 .80 54 2.05 1.07 14.0 .36 .78 22 .99 .63 32 1.08 .82 40 1.32 .93 58 1.80 1.19 – – – 24 .86 .70 36 .84 .96 44 1.08 1.07 62 1.56 1.36 36 30 13 – – – 26 .72 .76 38 .72 1.03 48 .85 1.23 66 1.32 1.52 44 40 14 15-1/2 12-1/2 – – – 28 .60 .82 40 .66 1.11 50 .72 1.33 68 1.23 1.58 – – – 30 .45 .93 42 .54 1.19 52 .66 1.38 70 1.11 1.66 62 60 15 17-1/2 14-1/2 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F9 Air Atomizing Nozzles Pressure Spray Set-ups, Internal Mix, 1/8J and 1/4J Series Performance Data Round Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SU12A SU12 SU22B SU22 SU42 Fluid Cap 2050 + Air Cap 73160 Fluid Cap 2850 + Air Cap 73160 Fluid Cap 40100 + Air Cap 1401110 Fluid Cap 60100 + Air Cap 1401110 Fluid Cap 100150 + Air Cap 1891125 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air* Liquid* Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. 10.0 .66 .66 18.0 1.44 .87 24 1.98 1.00 30 2.40 1.14 40 3.30 1.36 12.0 .54 .77 20 1.32 .98 28 1.68 1.17 34 2.16 1.29 46 2.94 1.54 14.0 .42 .90 22 1.20 1.06 32 1.44 1.35 38 1.92 1.47 52 2.58 1.83 – – – 24 1.08 1.16 34 1.32 1.46 42 1.62 1.68 58 – – – 26 .90 1.26 36 1.20 1.57 44 1.50 1.78 – – – – – – 38 1.11 1.66 46 1.38 1.88 – – – – – – 40 1.02 1.76 48 12.0 1.26 .73 22 2.16 1.05 30 2.90 1.24 16.0 1.08 .94 26 1.74 1.26 34 2.46 1.42 20 .90 1.15 30 1.44 1.47 38 22 .81 1.25 34 1.26 1.67 24 .78 1.36 38 26 .77 1.43 40 28 .76 1.56 16.0 Spray Angle A (°) B (in.) D (ft.) 12 10 12 17 12 20 20 13 18 13 2.28 2.09 34 30 13 19 14 62 2.10 2.26 42 40 13 20 15 66 1.86 2.46 1.32 1.98 70 1.68 2.67 58 60 15 22 17 36 4.32 1.26 48 5.82 1.50 40 3.85 1.36 52 5.28 1.65 22 10 12 19 13 2.10 1.65 44 3.55 1.56 56 4.92 1.73 34 20 13 20 14 42 1.74 1.87 48 2.80 1.78 60 4.56 1.88 42 30 13 21 15 1.08 1.87 46 1.50 2.03 52 2.46 2.01 64 4.08 2.08 1.02 1.96 50 1.24 2.25 56 2.16 2.20 68 3.72 2.25 48 40 14 22 16 42 .94 2.04 52 1.20 2.36 60 1.86 2.36 70 3.60 2.34 60 60 15 3.44 2.68 28 5.03 3.71 40 6.10 4.72 48 7.75 5.30 65 10.7 6.74 20 2.35 3.20 32 3.70 4.17 44 5.03 5.17 55 5.95 6.07 75 8.67 7.73 24 10 18 26 16 22 1.90 3.46 36 2.64 4.65 48 3.95 5.65 65 3.55 7.28 80 7.65 8.25 40 20 20 30 20 24 1.54 3.70 40 1.85 5.13 55 2.30 6.50 75 1.95 8.50 85 6.65 8.80 55 30 20 32 22 26 1.23 3.97 44 1.30 5.63 60 1.56 7.12 80 1.40 9.10 90 5.64 9.40 28 .96 4.22 48 .90 6.10 65 1.08 7.75 85 1.00 9.70 95 4.63 10.0 75 40 21 36 26 30 .72 4.48 50 .76 6.36 70 .73 8.35 90 .72 10.3 100 3.62 10.6 85 60 21 38 30 12.0 8.1 2.00 20 13.6 2.55 30 16.3 3.25 38 19.5 3.74 54 25.7 4.66 14.0 6.6 2.32 22 12.0 2.85 34 13.1 3.75 42 16.5 4.20 60 21.8 5.34 14 10 17 24 16 16.0 4.9 2.66 24 10.2 3.15 38 9.9 4.32 46 13.6 4.71 65 18.5 5.98 26 20 18 27 19 18.0 3.4 3.00 26 8.6 3.45 40 8.7 4.61 50 10.8 5.30 70 15.2 6.68 40 30 20 30 22 – – – 28 7.2 3.75 42 7.6 4.90 52 9.6 5.58 75 12.2 7.80 – – – 30 5.9 4.05 44 6.6 5.20 54 8.6 5.85 80 10.0 8.14 50 40 20 31 23 – – – 32 4.6 4.35 46 5.6 5.50 56 7.6 6.14 85 8.0 70 60 21 36 28 14 10 19 35 20 24 20 20 39 23 34 30 21 41 25 44 40 21 42 26 54 60 22 46 30 8.90 14.0 11.7 3.05 20 27.5 3.04 28 36.6 3.55 32 49.4 3.31 42 70.6 3.17 16.0 8.5 3.60 22 23.0 3.49 30 32.6 3.96 36 42.2 4.10 46 65.0 3.85 – – – 24 18.0 3.95 32 28.7 4.36 40 35.1 4.90 50 59.0 4.63 – – – 26 14.4 4.40 34 24.8 4.78 44 28.0 5.66 54 53.2 5.40 – – – 28 11.3 4.85 36 20.9 5.20 46 24.5 6.05 58 47.4 6.16 – – – – – – 38 17.5 5.60 48 21.3 6.45 65 37.8 7.54 – – – – – – 40 14.6 6.03 50 18.4 6.86 70 30.0 8.55 23-1/2 17-1/2 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F10 Pressure Spray Set-ups, Internal Mix, 1/8J and 1/4J Series Features and Benefits Air Caps • For wide angle round spray, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Wide angle round spray and 360° circular spray air caps produce hollow cone, wide angle round spray and 360° circular spray patterns. Fluid cap Air cap C B A Wide angle round spray pattern 6" (15 cm) 9" (23 cm) 15" (38 cm) D 1158 retainer ring 3612 gasket Air Atomizing Nozzles 1158 retainer ring and 3612 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Wide Angle Round Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SU16 Fluid Cap 2050 + Air Cap 67-6-20-70° Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Fluid Cap 60100 SU26 + Air Cap 140-6-37-70° Spray Dimensions Liquid Pressure 10 20 30 40 60 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) 8.0 1.41 .36 14.0 2.10 .42 22 2.36 .56 30 2.53 .68 44 2.95 .81 10.0 1.14 .43 16.0 1.90 .50 26 2.02 .69 34 2.23 .81 48 2.72 .94 12.0 .79 .50 18.0 1.68 .56 30 1.61 .83 38 1.90 .94 55 2.30 1.20 14.0 .45 .60 20 1.44 .64 34 1.15 1.00 42 1.50 1.1 60 1.92 1.40 – – – 22 1.17 .71 36 .91 1.07 46 1.10 1.26 65 1.50 1.60 – – – Fluid Cap 40100 SU26B + Air Cap 140-6-37-70° *At the stated pressure in psi. B (in.) C (in.) D (ft.) 7 9 5 10 10 5-1/2 20 20 6 34 30 6-1/2 8 10 42 40 6-1/2 8 10-1/2 9 60 60 7-1/2 9 12 13 12 10 7 7-1/2 9-1/2 6 7 24 .91 .80 38 .68 1.16 48 .90 1.35 70 1.07 1.80 12.0 1.85 1.78 22 3.30 2.30 30 5.10 2.54 38 6.40 2.84 54 8.76 3.44 14.0 .55 2.20 24 2.20 2.67 32 4.25 2.85 42 4.70 3.42 56 8.10 3.74 – – – 26 1.20 3.05 34 3.35 3.18 44 3.90 3.72 58 7.44 4.03 24 20 7-1/2 10 13 8 – – – – – – 36 2.50 3.50 46 3.06 4.05 60 6.76 4.32 34 30 7-1/2 10 13 10-1/2 – – – – – – 38 1.60 3.85 48 2.25 4.42 65 5.10 5.10 – – – – – – 40 .70 4.30 50 1.40 4.84 70 3.50 6.00 46 40 8 – – – – – – – – – 52 .60 5.34 75 1.85 6.95 60 60 8-1/2 11 10.0 6.3 1.14 20 9.0 1.60 30 11.2 2.04 40 12.4 2.54 56 16.2 2.75 12.0 3.6 1.54 22 6.9 2.00 32 9.3 2.44 42 10.6 2.92 58 14.8 3.11 12 10 7-1/2 10 14.0 2.0 2.00 24 5.1 2.40 34 7.4 2.80 44 8.8 3.33 60 13.8 3.50 22 20 8 10-1/2 14-1/2 10-1/2 – – – 26 3.3 2.80 36 5.4 3.20 46 7.1 3.72 65 9.8 4.42 34 30 8 10-1/2 14-1/2 13-1/2 – – – – – – 38 3.6 3.60 48 5.4 4.14 70 6.5 5.36 – – – – – – 40 2.3 3.98 50 3.6 4.51 75 4.0 6.31 46 40 8 11 – – – – – – – – – 52 2.2 4.91 80 2.4 6.51 65 60 8 11 9-1/2 12-1/2 6 10-1/2 13-1/2 13-1/2 14-1/2 19-1/2 14 15 7 16-1/2 15-1/2 22-1/2 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F11 Air Atomizing Nozzles Pressure Spray Set-ups, Internal Mix, 1/8J and 1/4J Series Performance Data Wide Angle Round Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) Fluid Cap 60100 SU29 + Air Cap 140-6-52-70° Fluid Cap 40100 SU30 + Air Cap 120-6-35-60° Fluid Cap 100150 SU46 + Air Cap 189-6-62-70° 18.0 9.4 3.0 30 13.4 4.15 44 15.3 5.45 60 15.6 7.05 80 21.4 8.55 22 7.7 3.6 34 11.9 4.65 48 13.8 5.9 70 12.5 8.25 85 19.5 9.15 26 6.0 4.13 38 10.3 5.1 55 11.3 6.75 80 9.3 9.45 90 17.9 9.75 28 5.2 4.4 42 8.9 5.6 65 7.8 8.0 85 7.8 10.05 30 4.4 4.7 46 7.3 6.1 70 6.1 8.6 90 6.2 32 3.7 5.0 50 5.8 6.65 75 4.5 9.25 95 4.8 34 3.0 5.25 60 2.4 7.95 80 3.3 9.85 100 3.7 16.0 3.24 1.43 28 4.60 1.96 42 5.27 2.67 18.0 2.61 1.59 32 3.37 2.27 46 4.0 20 2.08 1.75 36 2.45 2.55 22 1.62 1.90 40 24 1.30 2.06 42 26 1.04 2.20 28 .82 24 26 B (in.) C (in.) D (ft.) 10 13 18 28 10 8 42 20 8 95 16.5 10.35 65 30 8-1/2 11 14-1/2 27 10.7 100 9 11-1/2 15 30 – 11.9 – 15.1 10.95 85 – – 90 – – 40 11.3 9-1/2 12-1/2 16 34 55 5.69 3.30 80 7.10 4.50 2.96 60 4.24 3.68 85 5.80 4.88 48 3.45 3.11 65 3.15 4.06 90 4.65 5.27 1.75 2.85 50 3.03 3.26 70 2.31 4.44 95 3.75 5.65 1.45 3.00 55 2.11 3.63 75 1.72 4.82 100 3.00 6.03 44 1.21 3.14 60 1.47 3.98 80 1.32 5.20 – – – 2.35 46 1.0 3.28 65 1.03 4.36 85 1.05 5.58 – – – 6.7 5.5 38 10.7 7.4 48 16.5 8.8 60 18.6 10.4 85 29.2 13.7 5.2 5.9 42 7.6 8.3 52 12.5 9.6 65 13.7 11.4 90 24.6 14.7 28 4.0 6.3 44 6.2 8.7 56 9.2 10.4 70 10.0 12.4 95 20.7 15.8 30 3.0 6.8 46 5.0 9.1 60 6.6 11.3 75 7.4 13.5 100 17.5 16.9 32 2.0 7.2 48 4.0 9.5 62 5.6 11.7 80 5.5 14.5 – – – – – – 50 3.0 9.9 65 4.4 12.3 85 4.0 15.5 – – – – – – 52 2.4 10.3 70 2.6 13.3 90 2.5 16.6 – – – 60 10-1/2 13-1/2 21 22 10 6 7-1/2 9 9 40 20 6-1/2 8 9-1/2 15 50 30 6-1/2 8 9-1/2 18 70 40 7 8-1/2 10 24 90 60 7-1/2 9-1/2 11 31 28 10 9-1/2 18 18 46 20 10 13-1/2 18-1/2 21 60 30 11 14-1/2 20 24 75 40 11-1/2 15 21 26 90 60 13 16-1/2 23 32 13 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. 360° Circular Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SU340C Fluid Cap 60150 + Air Cap 189-6-62160HC *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Liquid Pressure 10 20 30 40 60 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. 20 4.0 2.45 34 6.6 4.09 50 7.1 6.38 60 11.0 7.6 85 14.4 11.8 22 2.8 2.7 38 4.4 4.8 52 6.2 6.75 65 8.3 8.63 90 12.0 13.0 24 2.0 2.97 42 2.8 5.5 56 4.4 7.55 70 6.1 9.78 95 9.8 14.1 26 1.5 3.3 46 1.7 6.34 60 3.2 8.41 80 3.1 12.44 100 7.8 15.4 28 1.1 3.62 48 1.3 6.85 70 1.3 11.75 90 1.4 – – – 15.4 360° circular spray pattern Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F12 Pressure Spray Set-ups, Internal Mix, 1/8J and 1/4J Series Features and Benefits Air Caps • For flat spray pattern, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Flat spray and deflected flat spray air caps produce flat or deflected flat spray patterns. Fluid cap Air cap C B A Flat spray pattern 6" (15 cm) 9" (23 cm) 15" (38 cm) 3612 gasket Air Atomizing Nozzles 1158 retainer ring D 1158 retainer ring and 3612 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Flat Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SU13A SU13 SUN13 Fluid Cap 2050 + Air Cap 73328 Fluid Cap 2850 + Air Cap 73328 Fluid Cap 2850 + Air Cap 73335 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. 10.0 1.44 .84 18.0 2.17 1.12 28 2.49 1.47 38 2.77 1.84 55 3.41 2.43 12.0 1.25 .96 22 1.82 1.31 32 2.19 1.64 42 2.49 2.01 65 2.83 2.85 14.0 1.09 1.08 26 1.50 1.50 36 1.89 1.82 46 2.20 2.19 75 16.0 .93 1.20 30 1.20 1.68 40 1.58 2.00 50 1.93 2.37 18.0 .79 1.32 34 .93 1.87 44 1.30 2.18 60 1.25 2.81 20 .65 1.43 38 .68 2.07 48 1.03 2.36 65 .93 22 .53 1.55 40 .57 2.16 55 .65 2.68 70 .65 12.0 2.17 .70 20 3.35 .96 30 3.98 1.27 14.0 1.80 .82 24 2.71 1.14 34 3.41 1.45 16.0 1.45 .95 28 2.06 1.34 38 18.0 A (in.) B (in.) C (in.) D (ft.) 16 10 10 14 18 8-1/2 2.26 3.26 30 20 14 19 26 10 85 1.69 3.67 40 30 15 21 30 10-1/2 90 1.40 3.88 3.02 95 1.13 4.09 50 40 18-1/2 24 34 11 3.25 100 .88 4.29 85 60 22 29 37 13 38 4.66 1.49 65 4.8 2.38 42 4.14 1.65 70 4.21 2.62 16 10 14 18 28 7 2.85 1.64 46 3.6 1.85 75 3.63 2.86 30 20 17 24 32 8 1.08 1.07 30 1.76 1.45 42 2.29 1.85 50 3.08 2.05 80 3.05 3.10 42 30 20 26 35 8-1/2 20 .77 1.2 32 1.44 1.56 46 1.72 2.07 60 1.76 2.58 85 2.48 3.35 – – – 34 1.18 1.67 48 1.43 2.18 65 1.2 2.84 90 1.98 3.60 50 40 23 30 38 9 – – – 36 .94 1.78 50 1.2 2.28 70 .76 3.09 95 1.57 3.85 80 60 23 30 38 10-1/2 14.0 2.4 .89 22 3.2 1.13 34 3.4 1.63 40 4.4 1.77 60 5.0 2.53 16.0 2.1 1.05 26 2.8 1.38 38 2.9 1.86 44 3.8 1.99 65 4.4 2.73 20 10 4 5 7 10 18.0 1.7 1.14 30 2.1 1.62 42 2.3 2.07 48 3.3 2.22 70 3.9 3.00 34 20 5 6 8 12 20 1.4 1.26 34 1.5 1.87 46 1.8 2.36 54 2.6 2.55 75 3.4 3.25 46 30 5 7 9 13 24 .81 1.54 38 1.2 2.1 50 1.4 2.58 60 1.9 2.98 80 3.0 3.57 28 .54 1.76 42 .72 2.38 60 .60 3.16 70 1.1 3.53 90 2.3 4.12 54 40 6 9 11 14 32 .30 1.96 48 .39 2.69 70 .33 3.65 85 .40 4.27 100 2.0 4.65 75 60 8 10 13 16 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F13 Air Atomizing Nozzles Pressure Spray Set-ups, Internal Mix, 1/8J and 1/4J Series Performance Data Flat Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SU14 SUN23 Fluid Cap 2850 + Air Cap 73320 Fluid Cap 60100 + Air Cap 125340 SU23B Fluid Cap 40100 + Air Cap 125328 SU23 Fluid Cap 60100 + Air Cap 125328 SU43 Fluid Cap 100150 + Air Cap 189351 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) 18.0 20 22 24 26 28 – 14.0 16.0 18.0 20 – – – 16.0 18.0 20 22 24 – 12.0 14.0 16.0 18.0 20 22 – 14.0 16.0 – – – – – 1.04 .80 .62 .47 .35 .25 – 4.5 2.9 2.0 .84 – – – 2.95 2.25 1.72 1.32 1.00 – 7.0 5.4 4.2 3.3 2.7 2.0 – 7.7 5.0 – – – – – 1.05 1.15 1.25 1.35 1.45 1.55 – .80 .97 1.17 1.42 – – – 1.92 2.10 2.30 2.50 2.70 – 1.15 1.35 1.57 1.69 1.97 2.20 – 3.17 3.83 – – – – – 30 34 36 38 40 42 44 24 26 28 30 32 34 36 28 30 32 34 36 – 22 26 30 32 34 36 38 26 28 – – – – – 1.56 1.10 .90 .74 .60 .47 .35 7.5 6.0 4.5 3.4 2.4 1.3 .80 4.45 3.87 3.30 2.78 2.28 – 11.5 8.3 6.0 5.1 4.3 3.6 3.0 10.5 7.0 – – – – – 1.43 1.61 1.70 1.79 1.88 1.97 2.07 1.24 1.44 1.68 1.82 2.06 2.32 2.61 2.66 2.84 3.04 3.22 3.40 – 1.65 2.02 2.40 2.60 2.78 2.97 3.16 4.55 5.15 – – – – – 42 44 46 48 50 55 – 34 36 38 40 42 46 50 38 40 42 44 46 48 34 38 42 46 48 50 52 34 36 38 40 42 – – 2.06 1.80 1.57 1.35 1.13 .70 – 9.5 7.8 6.5 5.2 4.1 2.6 1.1 5.94 5.40 4.86 4.32 3.78 3.25 12.4 9.8 7.8 5.9 5.0 4.3 3.7 20.8 16.6 12.8 9.5 6.7 – – 1.75 1.85 1.94 2.04 2.13 2.36 – 1.74 1.96 2.2 2.53 2.65 3.25 3.72 3.22 3.40 3.55 3.74 3.93 4.12 2.20 2.57 2.95 3.34 3.52 3.71 3.90 4.75 5.25 5.8 6.35 6.85 – – 55 60 65 70 – – – 44 46 48 52 56 60 65 46 50 52 54 56 58 46 50 54 56 60 65 70 42 44 46 48 50 52 54 2.16 1.60 1.15 .76 – – – 11.1 9.7 8.4 5.7 3.9 2.4 1.1 7.50 6.45 5.90 5.40 4.87 4.34 13.7 10.9 8.7 7.8 6.4 4.6 3.3 29.4 25.1 20.8 16.7 13.1 10.0 7.3 2.15 2.38 2.62 2.85 – – – 2.2 2.46 2.69 3.3 3.84 4.36 5.04 3.66 3.97 4.15 4.32 4.50 4.70 2.75 3.14 3.51 3.70 4.06 4.53 5.00 5.15 5.6 6.05 6.6 7.15 7.75 8.3 75 80 85 90 – – – 56 60 65 70 80 90 95 65 70 75 80 85 90 65 75 80 85 90 95 100 58 60 65 70 75 80 – 3.20 2.66 2.19 1.75 – – – 19.8 16.7 13.5 9.7 4.8 1.8 .70 9.70 8.60 7.50 6.40 5.30 4.25 18.3 12.6 10.6 8.7 6.9 5.5 4.5 44.7 41.0 31.4 22.5 15.0 8.7 – 2.66 2.90 3.13 3.36 – – – 2.56 2.97 3.5 4.33 5.73 7.4 8.38 4.80 5.20 5.60 6.00 6.48 6.96 3.56 4.47 4.95 5.40 5.85 6.30 6.76 6.05 6.42 7.45 8.75 10.1 11.45 – B (in.) C (in.) D (ft.) 22 10 10 13 18 6 38 20 14 20 27 6-1/2 46 30 23 29 36 6-1/2 60 40 24 29 37 7 80 60 25 30 38 7-1/2 16 10 4 5 6 8 30 20 4 5 7 10 40 30 5 7 9 11 52 40 6 8 11 12 70 60 8 10 14 13 20 32 42 54 75 10 20 30 40 60 6 9 10 12 13 7 11 13 15 16 8 13 18 18 19 10 10-1/2 11 11-1/2 13 16 10 7 9 12 11 32 20 9 12 16 11-1/2 46 30 10 13 17 12 56 40 12 15 19 12-1/2 85 60 13 16 20 14-1/2 14 10 7 8 10 11 26 20 10 12 17 12-1/2 38 30 10 12 18 14 48 40 13 16 21 15 70 60 14 17 23 17 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Deflected Flat Spray Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SU240E Fluid Cap 28150 + Air Cap 189110-75° *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Liquid Pressure 10 20 30 40 60 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. 6.0 8.0 10.0 12.0 – 2.9 2.5 2.0 1.5 – 1.6 1.9 2.3 2.7 – 14.0 16.0 18.0 20 22 3.9 3.5 3.1 2.8 2.3 2.6 2.8 3.1 3.5 3.8 22 24 26 30 34 4.7 4.3 4.0 3.3 2.3 3.3 3.6 3.8 4.5 5.2 26 32 38 44 46 5.8 4.8 3.8 2.8 2.3 3.6 4.4 5.3 6.2 6.6 38 46 54 62 70 7.4 6.4 5.3 4.2 2.8 4.6 5.5 6.6 7.8 9.4 Deflected flat spray pattern Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F14 Pressure Spray Set-ups, External Mix, 1/8J and 1/4J Series Features and Benefits Air Caps • Atomization can be controlled by varying the air pressure without changing liquid flow rates with external mix set-ups. • For flat spray, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. External mix air caps produce a flat spray pattern. • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • The liquid and compressed air or gas are mixed externally to produce a completely atomized spray. C B A Fluid cap Air cap Flat spray pattern 6" (15 cm) 9" (23 cm) 15" (38 cm) D 3612 gasket 1158 retainer ring Air Atomizing Nozzles 1158 retainer ring and 3612 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Flat Spray (External Mix) Spray Set-up No. SUE15B Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap 1650 + Air Cap 67228-45° *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 3 5 10 20 40 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) B (in.) C (in.) D (ft.) 3.0 .80 .89 5.0 1.0 .93 10.0 1.4 1.1 20 2.0 1.6 40 2.8 2.6 5.0 .80 .93 10.0 1.0 1.1 15.0 1.4 1.4 25 2.0 1.9 50 2.8 3.0 3 3 3-1/2 6 9 3 15 3 3-1/2 6 9 4 10.0 .80 1.1 15.0 1.0 1.4 20 1.4 1.6 30 2.0 2.1 60 2.8 3.6 20 5 4 6 9 4 15.0 .80 1.4 20 1.0 1.6 25 1.4 1.9 40 2.0 2.6 70 2.8 4.2 20 20 4-1/2 7 10 5 20 .80 1.6 25 1.0 1.9 30 1.4 2.1 50 2.0 3.0 75 2.8 4.5 25 10 4-1/2 6 9-1/2 5 40 20 5 7 11 6 70 40 6 7 9-1/2 8 25 .80 1.9 30 1.0 2.1 40 1.4 2.6 60 2.0 3.6 80 2.8 4.9 30 .80 2.1 40 1.0 2.6 50 1.4 3.0 80 2.0 4.9 90 2.8 5.6 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F15 Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, 1/8J and 1/4J Series Performance Data Flat Spray (External Mix) Spray Set-up No. SUE18B SUE15A SUE18A SUE15 SUE18 Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap 1650 + Air Cap 62240-60° Fluid Cap 2050 + Air Cap 67228-45° Fluid Cap 2050 + Air Cap 62240-60° Fluid Cap 2850 + Air Cap 67228-45° Fluid Cap 2850 + Air Cap 62240-60° *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 3 5 10 20 40 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) B (in.) C (in.) D (ft.) 11 12 14 13 12 14 15 13 16 18 17 16 19 20 4 6 6 8 9 8-1/2 9 2.8 6 8 8 15 20 15 20 5 10 20 20 20 30 40 8 9 11 11 10 11 12 4.4 2.9 5 3 3 50 4.4 3.0 20 3 3-1/2 6 2.6 60 4.4 3.6 25 5 4 6-1/2 3.1 3.0 70 4.4 4.2 25 20 5 7-1/2 11-1/2 60 3.1 3.6 75 4.4 4.5 30 10 5 7 10 6 3.0 70 3.1 4.2 90 4.4 5.6 50 20 5 8-1/2 12 8 2.2 3.6 90 3.1 5.6 95 4.4 5.8 75 40 6 7-1/2 10 10 8.0 2.2 1.0 10.0 3.1 1.2 15.0 4.4 1.6 1.2 10.0 2.2 1.2 20 3.1 1.9 20 4.4 1.9 1.6 1.6 20 2.2 1.9 30 3.1 2.5 30 4.4 2.5 20 1.6 1.9 30 2.2 2.5 35 3.1 2.8 35 4.4 2.8 10 15 10 20 35 25 25 5 10 20 20 20 30 40 11 12 15 14 13 15 16 13 15 18 17 16 18 19 16 19 23 22 20 23 26 5 7 6 8 10 9 9-1/2 1.1 15.0 3.0 1.4 20 4.2 1.6 35 6.0 2.4 50 8.4 3.0 10 3 5 6-1/2 10 4 2.3 1.4 20 3.0 1.6 25 4.2 1.9 40 6.0 2.6 60 8.4 3.6 25 3 5 6-1/2 10 6 20 2.3 1.6 25 3.0 1.9 30 4.2 2.1 50 6.0 3.0 70 8.4 4.2 30 5 5 7 9-1/2 6 25 2.3 1.9 30 3.0 2.1 40 4.2 2.6 60 6.0 3.6 75 8.4 4.5 35 20 5-1/2 8 12-1/2 6 30 2.3 2.1 40 3.0 2.6 50 4.2 3.0 70 6.0 4.2 80 8.4 4.9 40 10 5-1/2 7-1/2 12 7-1/2 40 2.3 2.6 50 3.0 3.0 60 4.2 3.6 80 6.0 4.9 90 8.4 5.6 60 20 5-1/2 8 14 10 50 2.3 3.0 60 3.0 3.6 70 4.2 4.2 90 6.0 5.6 100 8.4 6.2 75 40 6-1/2 8 12 13 6.0 2.3 .88 6.0 3.0 .88 6.0 4.2 .88 10.0 6.0 1.2 20 8.4 1.9 7.0 2.3 .97 8.0 3.0 1.0 8.0 4.2 1.0 12.0 6.0 1.4 25 8.4 2.2 8.0 2.3 1.0 9.0 3.0 1.1 10.0 4.2 1.2 15.0 6.0 1.6 30 8.4 2.5 10.0 2.3 1.2 10.0 3.0 1.2 12.0 4.2 1.4 20 6.0 1.9 35 8.4 2.8 8 8 10 15 20 25 30 5 10 20 20 20 30 40 14 14 15 16 17 16 16 19 19 19 20 21 20 20 24 25 25 26 26 27 27 6 5 6 7 8 9 9-1/2 5.0 .80 .78 5.0 1.0 .78 6.0 1.4 .88 8.0 2.0 1.0 10.0 2.8 1.2 6.0 .80 .88 6.0 1.0 .88 8.0 1.4 1.0 10.0 2.0 1.2 15.0 2.8 1.6 7.0 .80 .97 8.0 1.0 1.0 10.0 1.4 1.2 15.0 2.0 1.6 25 2.8 2.2 8.0 .80 1.0 10.0 1.0 1.2 12.0 1.4 1.4 20 2.0 1.9 35 2.8 5.0 1.2 .93 10.0 1.6 1.1 15.0 2.2 1.4 25 3.1 1.9 45 10.0 1.2 1.1 15.0 1.6 1.4 20 2.2 1.6 30 3.1 2.1 15.0 1.2 1.4 20 1.6 1.6 25 2.2 1.9 40 3.1 20 1.2 1.6 25 1.6 1.9 30 2.2 2.1 50 25 1.2 1.9 30 1.6 2.1 40 2.2 2.6 30 1.2 2.1 40 1.6 2.6 50 2.2 40 1.2 2.6 50 1.6 3.0 60 5.0 1.2 .78 5.0 1.6 .78 8.0 1.2 1.0 10.0 1.6 10.0 1.2 1.2 15.0 15.0 1.2 1.6 10.0 2.3 15.0 5-1/2 8-1/2 3-1/2 8-1/2 5-1/2 9 6 7 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F16 Pressure Spray Set-ups, External Mix, 1/8J and 1/4J Series Performance Data Flat Spray (External Mix) SUE25B SUE28B SUE25A SUE28A SUE28 Fluid Cap 35100 + Air Cap 134255-45° Fluid Cap 35100 + Air Cap 122281-60° Fluid Cap 40100 + Air Cap 134255-45° Fluid Cap 40100 + Air Cap 122281-60° Fluid Cap 60100 + Air Cap 122281-60° Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 3 5 10 20 40 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. A (in.) B (in.) C (in.) D (ft.) 5-1/2 10.0 3.6 3.0 15.0 4.7 3.6 20 6.6 4.1 35 9.4 6.3 45 13.2 7.5 10 3 5 7-1/2 10 15.0 3.6 3.6 20 4.7 4.1 25 6.6 4.9 40 9.4 6.9 50 13.2 8.2 25 3 5 7-1/2 10 9 20 3.6 4.1 25 4.7 4.9 30 6.6 5.5 50 9.4 8.0 55 13.2 9.0 30 5 6 7-1/2 11 10 25 3.6 4.9 30 4.7 5.5 35 6.6 6.3 60 9.4 9.4 60 13.2 9.7 35 10 6 8-1/2 11 11-1/2 30 3.6 5.5 40 4.7 6.9 40 6.6 6.9 70 9.4 11.0 70 13.2 11.1 35 20 6-1/2 9 14 12 20 6-1/2 9 14-1/2 14 6-1/2 8-1/2 12-1/2 16 40 3.6 6.9 50 4.7 8.0 50 6.6 8.0 80 9.4 12.7 80 13.2 12.7 60 50 3.6 8.0 60 4.7 9.4 60 6.6 9.4 90 9.4 14.5 90 13.2 14.5 70 40 8.0 3.6 3.2 10.0 4.7 3.6 20 6.6 5.5 30 9.4 7.4 45 13.2 10.0 10.0 3.6 3.6 15.0 4.7 4.6 30 6.6 7.4 40 9.4 9.1 60 13.2 12.6 15.0 3.6 4.6 25 4.7 6.5 35 6.6 8.3 50 9.4 10.9 75 13.2 15.2 20 3.6 5.5 30 4.7 7.4 40 6.6 9.1 60 9.4 12.6 80 13.2 16.0 20 30 30 45 60 55 60 5 10 20 20 20 30 40 13 13 14 15 15 16 15 10.0 4.8 3.0 20 6.1 4.1 25 8.7 4.9 40 12.3 6.9 50 17.4 8.2 10 3 6 7-1/2 10-1/2 7 15.0 4.8 3.6 25 6.1 4.9 30 8.7 5.5 45 12.3 7.5 60 17.4 9.7 25 3 6 7-1/2 10-1/2 10 20 4.8 4.1 30 6.1 5.5 35 8.7 6.3 50 12.3 8.0 70 17.4 11.1 35 5 6 8-1/2 13 11 25 4.8 4.9 35 6.1 6.3 40 8.7 6.9 60 12.3 9.4 75 17.4 12.0 40 10 6 8-1/2 14 12-1/2 30 4.8 5.5 40 6.1 6.9 50 8.7 8.0 70 12.3 11.0 80 17.4 12.7 40 20 6-1/2 10 14-1/2 13 20 6-1/2 10 14-1/2 16 15 16 18 19 19 20 20 19 22 23 26 25 27 28 12-1/2 14 13 15 17 15 16 40 4.8 6.9 50 6.1 8.0 60 8.7 9.4 80 12.3 12.7 90 17.4 14.5 60 50 4.8 8.0 60 6.1 9.4 70 8.7 11.0 90 12.3 14.5 95 17.4 15.1 75 40 7 9 14 19 8.0 4.8 3.2 10.0 6.1 3.6 15.0 8.7 4.6 35 12.3 8.3 50 17.4 10.9 15.0 4.8 4.6 20 6.1 5.5 25 8.7 6.5 45 12.3 10.0 65 17.4 13.5 20 4.8 5.5 25 6.1 6.5 35 8.7 8.3 55 12.3 11.7 85 17.4 16.8 25 4.8 6.5 30 6.1 7.4 40 8.7 9.1 60 12.3 12.6 95 17.4 18.5 15 25 35 45 60 60 70 3 10 20 20 20 30 40 13 14 15 13 12 13 13 15 19 18 17 17 17 17 20 25 25 24 23 24 24 11-1/2 10 12-1/2 14 16 17 13 10.0 9.9 3.6 15.0 12.7 4.6 25 18.0 6.5 45 25.5 10.0 75 36.0 15.2 15.0 9.9 4.6 20 12.7 5.5 30 18.0 7.4 50 25.5 10.9 85 36.0 16.8 20 9.9 5.5 30 12.7 7.4 40 18.0 9.1 70 25.5 14.3 95 36.0 18.5 25 9.9 6.5 35 12.7 8.3 45 18.0 10.0 80 25.5 16.0 100 36.0 19.4 30 40 45 65 80 55 90 5 10 20 20 20 30 40 16 18 19 17 15 19 16 22 23 23 21 20 25 22 30 32 31 30 26 33 31 12 13 14 16 19 14 19 Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F17 Air Atomizing Nozzles Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination *At the stated pressure in psi. Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, 1/8J and 1/4J Series Performance Data Flat Spray (External Mix) Spray Set-up No. SUE25 SUE45B SUE45A SUE45 Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap 60100 + Air Cap 134255-45° Fluid Cap 60150 + Air Cap 200278-45° Fluid Cap 80150 + Air Cap 200278-45° Fluid Cap 100150 + Air Cap 200278-45° *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 3 5 10 20 40 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. A (in.) B (in.) C (in.) 8 10 D (ft.) 15.0 9.9 3.6 25 12.7 4.9 35 18.0 6.3 45 25.5 7.5 55 36.0 9.0 15 3 6 20 9.9 4.1 30 12.7 5.5 40 18.0 6.9 50 25.5 8.0 60 36.0 9.7 30 3 6 8-1/2 11-1/2 25 9.9 4.9 35 12.7 6.3 45 18.0 7.5 55 25.5 8.7 65 36.0 10.5 40 5 7 9-1/2 14 11-1/2 30 9.9 5.5 40 12.7 6.9 50 18.0 8.0 60 25.5 9.4 70 36.0 11.1 45 20 8 11 15-1/2 12 36.0 12.7 50 10 15 13 36.0 14.5 60 20 8 11 15-1/2 14 36.0 16.0 80 40 7 9-1/2 15 19-1/2 35 40 9.9 9.9 6.3 6.9 45 50 12.7 12.7 7.5 8.0 60 70 18.0 9.4 18.0 11.0 70 80 25.5 11.0 25.5 12.7 80 90 7-1/2 10-1/2 9 10 50 9.9 8.0 60 12.7 9.4 80 18.0 12.7 90 25.5 14.5 100 25 10.0 8.3 25 12.9 8.3 35 18.0 10.5 55 25.5 14.5 – – – 25 3 6 8 11-1/2 10 30 10.0 9.2 30 12.9 9.2 40 18.0 11.6 60 25.5 15.7 – – – 40 3 6 8 12 11 35 10.0 10.5 35 12.9 10.5 45 18.0 12.5 65 25.5 17.0 – – – 40 5 6 8 12 13 40 10.0 11.6 40 12.9 11.6 50 18.0 13.4 70 25.5 18.4 – – – 50 10 6-1/2 8-1/2 12-1/2 45 10.0 12.5 45 12.9 12.5 55 18.0 14.5 75 25.5 20.0 – – – 55 20 6-1/2 8-1/2 13-1/2 15 6-1/2 9 13 15-1/2 9 13-1/2 18 14 15 50 10.0 13.4 50 12.9 13.4 60 18.0 15.7 80 25.5 21.2 – – – 60 60 10.0 15.7 60 12.9 15.7 70 18.0 18.4 90 25.5 24.2 – – – 70 20 6-1/2 30 17.4 9.2 40 22.5 11.6 55 31.5 14.5 70 44.7 18.4 – – – 30 3 6-1/2 9-1/2 13-1/2 11-1/2 35 17.4 10.5 45 22.5 12.5 60 31.5 15.7 75 44.7 20.0 – – – 45 3 7 9-1/2 14 14 40 17.4 11.6 50 22.5 13.4 65 31.5 17.0 80 44.7 21.2 – – – 55 5 7 10 14 16 45 17.4 12.5 55 22.5 14.5 70 31.5 18.4 85 44.7 22.5 – – – 70 10 7 10 14 18 50 17.4 13.4 60 22.5 15.7 75 31.5 20.0 90 44.7 24.2 – – – 70 20 8 10 15 18 60 17.4 15.7 70 22.5 18.4 80 31.5 21.2 – – – – 75 15 7 10 15 19 20 8 10 15 20 – – – – 80 72.0 21.2 – – – 40 3 7-1/2 10 14 15 72.0 22.5 – – – 55 3 8 10 14-1/2 16 72.0 24.2 – – – 65 5 8 10 14-1/2 17 – – – – 75 10 8-1/2 10-1/2 15 18 – – – – – 80 15 8-1/2 10-1/2 16 18 – – – – – – 80 20 8-1/2 10-1/2 16 19 – – – – – – 85 20 8-1/2 10-1/2 16 20 70 17.4 18.4 80 22.5 21.2 90 31.5 24.2 – 40 27.9 11.6 50 36.0 13.4 65 50.6 17.0 80 45 27.9 12.5 55 36.0 14.5 70 50.6 18.4 85 50 27.9 13.4 60 36.0 15.7 75 50.6 20.0 90 55 27.9 14.5 65 36.0 17.0 80 50.6 21.2 – – 60 27.9 15.7 70 36.0 18.5 85 50.6 22.5 – 65 27.9 17.0 75 36.0 20.0 90 50.6 24.2 70 27.9 18.4 80 36.0 21.2 – – – – – – Add DF to part number for “Drip Free™” set-ups. Example: SU11DF. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F18 Pressure Spray Set-ups, External Mix, High Transfer Efficiency (HTE), 1/4J Series Features and Benefits C B A Flat spray pattern • A new air cap design enables the use of lower air pressures to achieve the same spray performance as conventional external mix set-ups. 6" (15 cm) 9" (23 cm) 15" (38 cm) • HTE set-ups operate at pressures as low as 5 psi (0.3 bar). • A large air chamber directly feeds the air exit orifices. Design provides high liquid transfer efficiency, minimal air loss, and minimal misting. D • Air consumption is reduced and maximum spray coverage on the target is achieved. C • See also B A Round spray pattern – Section G, Automatic Spray Nozzles Air Caps 6" (15 cm) 9" (23 cm) 15" (38 cm) D Air Atomizing Nozzles 1158 retainer ring and 3612 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. HTE air cap produces a flat spray and a round spray. Performance Data Flat Spray (External Mix) Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap PF28100 SU-HTE60D + Air Cap LP130262-60 Fluid Cap PF20100 SU-HTE60E + Air Cap LP130262-60 SU-HTE60F Fluid Cap PF16100 + Air Cap LP130262-60 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 5 10 15 20 30 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) 8.0 10.0 12.0 14.0 16.0 6.0 8.0 10.0 12.0 14.0 16.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 3.0 3.0 3.0 3.0 3.0 1.6 1.6 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0 3.3 3.8 4.2 4.5 4.9 2.8 3.3 3.8 4.2 4.5 4.9 2.3 2.8 3.3 3.8 4.2 4.5 4.9 8.0 10.0 12.0 14.0 16.0 6.0 8.0 10.0 12.0 14.0 16.0 – – 8.0 10.0 12.0 14.0 16.0 4.2 4.2 4.2 4.2 4.2 2.2 2.2 2.2 2.2 2.2 2.2 – – 1.4 1.4 1.4 1.4 1.4 3.3 3.8 4.2 4.5 4.9 2.8 3.3 3.8 4.2 4.5 4.9 – – 3.3 3.8 4.2 4.5 4.9 – 10.0 12.0 14.0 16.0 – 8.0 10.0 12.0 14.0 16.0 – – 8.0 10.0 12.0 14.0 16.0 – 5.1 5.1 5.1 5.1 – 2.6 2.6 2.6 2.6 2.6 – – 1.7 1.7 1.7 1.7 1.7 – 3.8 4.2 4.5 4.9 – 3.3 3.8 4.2 4.5 4.9 – – 3.3 3.8 4.2 4.5 4.9 – – 12.0 14.0 16.0 – – 10.0 12.0 14.0 16.0 – – 8.0 10.0 12.0 14.0 16.0 – – 6.0 6.0 6.0 – – 3.1 3.1 3.1 3.1 – – 2.0 2.0 2.0 2.0 2.0 – – 4.2 4.5 4.9 – – 3.8 4.2 4.5 4.9 – – 3.3 3.8 4.2 4.5 4.9 – – – 14.0 16.0 – – – – 14.0 16.0 – – – – 12.0 14.0 16.0 – – – 7.2 7.2 – – – – 3.7 3.7 – – – – 2.4 2.4 2.4 – – – 4.5 4.9 – – – – 4.5 4.9 – – – – 4.2 4.5 4.9 B (in.) C (in.) D (in.) 14 8 13 10 11 36 40 40 45 41 10 15 10 15 10 5 5 10 10 20 7 13 5 6 11-1/2 13-1/2 6 9 10 15 5 10 15 5 10 15 5 5 5 10 10 10 7 9 11 4 4-1/2 4-1/2 3 4-1/2 5-1/2 8 11 13 8 9 9 6-1/2 7 7-1/2 25 31 34 22 27 32 3 5 10 15 5 10 15 5 5 5 5 10 10 10 9-1/2 11 13 9 10 12 8 9 11-1/2 6-1/2 7-1/2 8-1/2 8-1/2 9-1/2 12 7-1/2 9 11 6 7-1/2 9-1/2 23 24 25 28 22 25 29 Add DF to part number for “Drip Free™” set-ups. Example: SU-HTE60D-DF. The operating pressures and flow rates are based on spraying water and air at room temperature. Adjustments may need to be made to accommodate other liquids with different characteristics. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F19 Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, High Transfer Efficiency (HTE), 1/4J Series Performance Data Flat Spray (External Mix) Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap PF35100 SU-HTE61C + Air Cap LP130285-60 Fluid Cap PF28100 SU-HTE61D + Air Cap LP130285-60 Fluid Cap PF20100 SU-HTE61E + Air Cap LP130285-60 SU-HTE61F Fluid Cap PF16100 + Air Cap LP130285-60 Fluid Cap PF28100 SU-HTE62D + Air Cap LP120262-90 Fluid Cap PF20100 SU-HTE62E + Air Cap LP120262-90 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 5 10 15 20 30 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) 6.0 4.7 3.5 – – – – – – – – – – – – 8.0 4.7 4.2 8.0 6.6 4.2 – – – – – – – – – 10.0 4.7 4.7 10.0 6.6 4.7 – – – – – – – – – 12.0 4.7 5.3 12.0 6.6 5.3 12.0 8.1 5.3 – – – – – – 14.0 4.7 5.8 14.0 6.6 5.8 14.0 8.1 5.8 14.0 9.4 5.8 14.0 11.4 5.8 16.0 4.7 6.2 16.0 6.6 6.2 16.0 8.1 6.2 16.0 9.4 6.2 16.0 11.4 6.2 6.0 3.0 3.5 – – – – – – – – – – – – 8.0 3.0 4.2 8.0 4.2 4.2 – – – – – – – – – 10.0 3.0 4.7 10.0 4.2 4.7 10.0 5.1 4.7 – – – – – – 12.0 3.0 5.3 12.0 4.2 5.3 12.0 5.1 5.3 – – – – – – 14.0 3.0 5.8 14.0 4.2 5.8 14.0 5.1 5.8 14.0 6.0 5.8 14.0 7.2 5.8 16.0 3.0 6.2 16.0 4.2 6.2 16.0 5.1 6.2 16.0 6.0 6.2 16.0 7.2 6.2 4.0 1.6 2.8 – – – – – – – – – – – – 6.0 1.6 3.5 – – – – – – – – – – – – 8.0 1.6 4.2 8.0 2.2 4.2 8.0 2.6 4.2 – – – – – – 10.0 1.6 4.7 10.0 2.2 4.7 10.0 2.6 4.7 10.0 3.1 4.7 10.0 3.7 4.7 12.0 1.6 5.3 12.0 2.2 5.3 12.0 2.6 5.3 12.0 3.1 5.3 12.0 3.7 5.3 14.0 1.6 5.8 14.0 2.2 5.8 14.0 2.6 5.8 14.0 3.1 5.8 14.0 3.7 5.8 16.0 1.6 6.2 16.0 2.2 6.2 16.0 2.6 6.2 16.0 3.1 6.2 16.0 3.7 6.2 4.0 1.0 2.8 – – – – – – – – – – – – 6.0 1.0 3.5 6.0 1.4 3.5 – – – – – – – – – 8.0 1.0 4.2 8.0 1.4 4.2 8.0 1.7 4.2 8.0 2.0 4.2 – – – 10.0 1.0 4.7 10.0 1.4 4.7 10.0 1.7 4.7 10.0 2.0 4.7 10.0 2.4 4.7 12.0 1.0 5.3 12.0 1.4 5.3 12.0 1.7 5.3 12.0 2.0 5.3 12.0 2.4 5.3 14.0 1.0 5.8 14.0 1.4 5.8 14.0 1.7 5.8 14.0 2.0 5.8 14.0 2.4 5.8 16.0 1.0 6.2 16.0 1.4 6.2 16.0 1.7 6.2 16.0 2.0 6.2 16.0 2.4 6.2 4.0 3.0 2.0 – – – – – – – – – – – – 6.0 3.0 2.5 6.0 4.2 2.5 – – – – – – – – – – 8.0 3.0 2.9 8.0 4.2 2.9 8.0 5.1 2.9 – – – – – 10.0 3.0 3.3 10.0 4.2 3.3 10.0 5.1 3.3 10.0 6.0 3.3 – – – 12.0 3.0 3.6 12.0 4.2 3.6 12.0 5.1 3.6 12.0 6.0 3.6 12.0 7.2 3.6 14.0 3.0 4.0 14.0 4.2 4.0 14.0 5.1 4.0 14.0 6.0 4.0 14.0 7.2 4.0 16.0 3.0 4.3 16.0 4.2 4.3 16.0 5.1 4.3 16.0 6.0 4.3 16.0 7.2 4.3 4.0 1.6 2.0 – – – – – – – – – – – – 6.0 1.6 2.5 – – – – – – – – – – – – – 8.0 1.6 2.9 8.0 2.2 2.9 – – – – – – – – 10.0 1.6 3.3 10.0 2.2 3.3 10.0 2.6 3.3 10.0 3.1 3.3 – – – 12.0 1.6 3.6 12.0 2.2 3.6 12.0 2.6 3.6 12.0 3.1 3.6 12.0 3.7 3.6 14.0 1.6 4.0 14.0 2.2 4.0 14.0 2.6 4.0 14.0 3.1 4.0 14.0 3.7 4.0 16.0 1.6 4.3 16.0 2.2 4.3 16.0 2.6 4.3 16.0 3.1 4.3 16.0 3.7 4.3 5 10 15 10 15 10 5 5 5 10 10 20 5 10 15 5 10 15 5 5 5 10 10 10 3 5 10 15 5 10 15 B (in.) C (in.) 10-1/2 14 20 9 11-1/2 12 6-1/2 9 12 10-1/2 14 16-1/2 9 11 13 12 16 20-1/2 7 5 4 9 6 5 D (in.) 27 37 43 37 43 35 7 8 6 7-1/2 5 6-1/2 11 12 8-1/2 9 6 8 29 36 57 33 37 43 5 5 5 5 10 10 10 8 10 14 7 7-1/2 9 3-1/2 5 6 3-1/2 4 5-1/2 9-1/2 10 11-1/2 7 8 9 6 7-1/2 9-1/2 18 24 29 30 27 35 39 3 5 10 15 5 10 15 5 5 5 5 10 10 10 10 8-1/2 7 7-1/2 11 8-1/2 8-1/2 12-1/2 14-1/2 10 12 9-1/2 12 10 11 12-1/2 15 10-1/2 11-1/2 10 11-1/2 29 33 34 33 32 33 33 3 5 10 15 10 10 20 5 5 5 5 10 15 10 7 11 11 7 14 16 13 11 16 12-1/2 14 13 13-1/2 7 8 15 17 16 18 17 16 34 38 42 45 40 50 48 3 5 10 15 5 10 15 5 5 5 5 10 10 10 10 13-1/2 15 7-1/2 9-1/2 10 7 8 8-1/2 6 6-1/2 7 7-1/2 11 11-1/2 6-1/2 9 10 6-1/2 8 8-1/2 21 28 33 39 26 29 37 Add DF to part number for “Drip Free™” set-ups. Example: SU-HTE60D-DF. The operating pressures and flow rates are based on spraying water and air at room temperature. Adjustments may need to be made to accommodate other liquids with different characteristics. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F20 Pressure Spray Set-ups, External Mix, High Transfer Efficiency (HTE), 1/4J Series Performance Data Flat Spray (External Mix) SU-HTE62F SU-HTE64C SU-HTE64D SU-HTE64E SU-HTE64F Fluid Cap PF16100 + Air Cap LP120262-90 Fluid Cap PF35100 + Air Cap LP130210060 Fluid Cap PF28100 + Air Cap LP130210060 Fluid Cap PF20100 + Air Cap LP130210060 Fluid Cap PF16100 + Air Cap LP130210060 Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 5 10 15 20 30 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) B (in.) C (in.) D (in.) 11 12-1/2 26 8-1/2 9-1/2 10-1/2 28 4.0 1.0 2.0 – – – – – – – – – – – – 3 5 6.0 1.0 2.5 6.0 1.4 2.5 – – – – – – – – – 5 5 8.0 1.0 2.9 8.0 1.4 2.9 8.0 1.7 2.9 8.0 2.0 2.9 – – – 10 5 10.0 1.0 3.3 10.0 1.4 3.3 10.0 1.7 3.3 10.0 2.0 3.3 10.0 2.4 3.3 15 5 3.6 5 10 9 4.0 10 10 15 12.0 14.0 1.0 1.0 3.6 4.0 12.0 14.0 1.4 1.4 3.6 4.0 12.0 14.0 1.7 1.7 3.6 4.0 12.0 14.0 2.0 2.0 3.6 4.0 12.0 14.0 2.4 2.4 9 6 7-1/2 8-1/2 6-1/2 7-1/2 24 9 25 11 12-1/2 26 8 9 12 26 10 7-1/2 9 11 26 16.0 1.0 4.3 16.0 1.4 4.3 16.0 1.7 4.3 16.0 2.0 4.3 16.0 2.4 4.3 6.0 4.7 4.0 – – – – – – – – – – – – 5 5 12 16 19 30 8.0 4.7 4.7 8.0 6.6 4.7 – – – – – – – – – 10 5 11 11-1/2 15 34 10.0 4.7 5.3 10.0 6.6 5.3 – – – – – – – – – 15 5 6 9 10 44 12.0 4.7 5.9 12.0 6.6 5.9 12.0 8.1 5.9 – – – – – – 5 10 14 16 19 29 14.0 4.7 6.5 14.0 6.6 6.5 14.0 8.1 6.5 14.0 9.4 6.5 14.0 11.4 6.5 10 10 12 16 18 35 15 10 8 12 13 41 16.0 4.7 7.1 6.0 3.0 4.0 – 8.0 3.0 4.7 8.0 10.0 3.0 5.3 10.0 4.2 12.0 14.0 3.0 3.0 5.9 6.5 16.0 12.0 14.0 6.6 7.1 16.0 8.1 7.1 16.0 9.4 7.1 16.0 11.4 7.1 – – – – – – – – – – – 5 5 11 13 14 39 4.2 4.7 – – – – – – – – – 10 5 8 10 13 40 5.3 10.0 5.1 5.3 – – – – – – 15 5 7 8 11 50 – 5 10 11 12 18 30 6.5 10 10 8 11 14 41 10 7 8 13 53 7 9 11 23 4.2 4.2 5.9 6.5 12.0 14.0 5.1 5.1 5.9 6.5 – 14.0 – 6.0 – 6.5 – 14.0 – 7.2 16.0 3.0 7.1 16.0 4.2 7.1 16.0 5.1 7.1 16.0 6.0 7.1 16.0 7.2 7.1 15 4.0 1.6 3.2 – – – – – – – – – – – – 3 5 6.0 1.6 4.0 – – – – – – – – – – – – 5 5 8.0 1.6 4.7 8.0 2.2 4.7 8.0 2.6 4.7 – – – – – – 10 5 5 5 6 33 10.0 1.6 5.3 10.0 2.2 5.3 10.0 2.6 5.3 10.0 3.1 5.3 10.0 3.7 5.3 15 5 5 5 5-1/2 39 12.0 1.6 5.9 12.0 2.2 5.9 12.0 2.6 5.9 12.0 3.1 5.9 12.0 3.7 5.9 5 10 7-1/2 8-1/2 9 29 6.5 10 10 5-1/2 6-1/2 7-1/2 35 10 5-1/2 6-1/2 7 43 14.0 1.6 6.5 14.0 14.0 2.6 6.5 14.0 3.1 6.5 14.0 3.7 7.1 16.0 2.6 7.1 16.0 3.1 7.1 16.0 3.7 7.1 – – – – – – – – – – – 3 5 9 11 13-1/2 27 1.4 4.0 – – – – – – – – – 5 5 7 9 11-1/2 27 1.4 4.7 8.0 1.7 4.7 8.0 2.0 4.7 – – – 10 5 6-1/2 8 10 30 10.0 1.4 5.3 10.0 1.7 5.3 10.0 2.0 5.3 10.0 2.4 5.3 15 5 5-1/2 7 8-1/2 30 5.9 12.0 1.4 5.9 12.0 1.7 5.9 12.0 2.0 5.9 12.0 2.4 5.9 5 10 9 11 13-1/2 28 6.5 14.0 1.4 6.5 14.0 1.7 6.5 14.0 2.0 6.5 14.0 2.4 6.5 10 10 7-1/2 9 10 29 7.1 15 10 5-1/2 7 8-1/2 29 1.6 7.1 4.0 1.0 3.2 – 6.0 1.0 4.0 6.0 8.0 1.0 4.7 8.0 10.0 1.0 5.3 12.0 1.0 14.0 1.0 1.0 6.5 25 15 16.0 16.0 2.2 6-1/2 6-1/2 8-1/2 7.1 16.0 16.0 2.2 1.4 7.1 16.0 1.7 7.1 16.0 2.0 7.1 16.0 2.4 Add DF to part number for “Drip Free™” set-ups. Example: SU-HTE60D-DF. The operating pressures and flow rates are based on spraying water and air at room temperature. Adjustments may need to be made to accommodate other liquids with different characteristics. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F21 Air Atomizing Nozzles Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination *At the stated pressure in psi. Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, High Transfer Efficiency (HTE), 1/4J Series Performance Data Round Spray (External Mix) Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination SU-HTE91A Fluid Cap PF2850 + Air Cap LP60650-60 SU-HTE91B Fluid Cap PF2050 + Air Cap LP60650-60 SU-HTE91C Fluid Cap PF1650 + Air Cap LP60650-60 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 5 10 15 20 30 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) 4.0 6.0 8.0 10.0 12.0 14.0 16.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 6.0 8.0 10.0 12.0 14.0 16.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.9 2.5 2.9 3.4 3.8 4.1 4.5 1.9 2.5 2.9 3.4 3.8 4.1 4.5 2.5 2.9 3.4 3.8 4.1 4.5 – 6.0 8.0 10.0 12.0 14.0 16.0 – – 8.0 10.0 12.0 14.0 16.0 – 8.0 10.0 12.0 14.0 16.0 – 4.2 4.2 4.2 4.2 4.2 4.2 – – 2.2 2.2 2.2 2.2 2.2 – 1.4 1.4 1.4 1.4 1.4 – 2.5 2.9 3.4 3.8 4.1 4.5 – – 2.9 3.4 3.8 4.1 4.5 – 2.9 3.4 3.8 4.1 4.5 – – 8.0 10.0 12.0 14.0 16.0 – – – 10.0 12.0 14.0 16.0 – – – – 14.0 16.0 – – 5.1 5.1 5.1 5.1 5.1 – – – 2.6 2.6 2.6 2.6 – – – – 1.7 1.7 – – 2.9 3.4 3.8 4.1 4.5 – – – 3.4 3.8 4.1 4.5 – – – – 4.1 4.5 – – 8.0 10.0 12.0 14.0 16.0 – – – 10.0 12.0 14.0 16.0 – – – – 14.0 16.0 – – 6.0 6.0 6.0 6.0 6.0 – – – 3.1 3.1 3.1 3.1 – – – – 2.0 2.0 – – 2.9 3.4 3.8 4.1 4.5 – – – 3.4 3.8 4.1 4.5 – – – – 4.1 4.5 – – 8.0 10.0 12.0 14.0 16.0 – – – – – 14.0 16.0 – – – – – – – – 7.2 7.2 7.2 7.2 7.2 – – – – – 3.7 3.7 – – – – – – – – 2.9 3.4 3.8 4.1 4.5 – – – – – 4.1 4.5 – – – – – – B (in.) C (in.) D (in.) 3 5 10 15 5 10 15 5 5 5 5 10 10 10 1 3-1/2 2 2 2-1/2 1-1/2 1 3 3-1/2 3-1/2 5 3-1/2 4 3-1/2 5 4-1/2 5-1/2 2-1/2 3-1/2 2-1/2 4 44 40 43 44 39 41 47 3 5 10 15 5 10 15 5 5 5 5 10 10 10 2 3-1/2 4-1/2 2-1/2 3 3-1/2 2 3-1/2 5 2 3 5 2-1/2 3 3-1/2 2 3-1/2 5 2 3 5 41 42 42 49 42 42 49 5 10 15 5 10 15 5 5 5 10 10 10 3-1/2 4 5 4 4-1/2 5-1/2 4 5 6 2 4 4-1/2 3 4 4-1/2 3 3-1/2 5 34 38 46 35 38 52 Add DF to part number for “Drip Free™” set-ups. Example: SU-HTE60D-DF. The operating pressures and flow rates are based on spraying water and air at room temperature. Adjustments may need to be made to accommodate other liquids with different characteristics. Ordering Info Complete Nozzle Assembly Nozzle Body* 1/4 l Inlet Conn. Spray Set-up Only Spray Set-up Spray Set-up J – SS + SU-HTE60D – SS l l l l Nozzle No. Material Code Spray Set-up Number Material Code HTE60D – l Spray Set-up Number SS l Material Code BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. *To order fluid cap only, use fluid cap number (shown in performance data charts and material code). To order air cap only, use air cap number (shown in performance data charts and material code). To order spray nozzle without set-up, use inlet connection, nozzle body and material code. To order Drip Free set-ups, add DF after set-up number: SU-HTE60D-DF – SS. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F22 Siphon/Gravity-Fed Spray Set-ups, External Mix, 1/8J and 1/4J Series Features and Benefits Air Caps • For round and flat sprays, angle “A” is maintained throughout distance “B”. Beyond “B”, the spray becomes turbulent and will project out to distance “D”. • When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed. Round spray and flat spray air caps produce round spray and flat spray patterns. • Designed to draw liquid through the feed line into the air flow where it is atomized. Round spray pattern A B D 1158 retainer ring and 3612 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Air Atomizing Nozzles Refer to page F3 for Siphon/Gravity-Fed Spray Set-ups diagram. Performance Data Flat Spray Spray Set-up No. SUF1 SUF2C SUF3B SUF4B Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap 2850 + Air Cap 73420 Fluid Cap 35100 + Air Cap 120432 Fluid Cap 40100 + Air Cap 122435 Fluid Cap 40100 + Air Cap 122440 *At the stated pressure in psi. Atomizing Air Liquid Capacity (gallons per hour)* Spray Dimensions at 8" Siphon Height Air Capacity scfm 18 12 6 4 8 12 24 36 10.0 .99 .35 .33 .30 .27 .25 .22 .17 .13 20 1.42 .31 .30 .29 .26 .25 .23 .19 .16 30 1.83 .18 .16 .15 .11 .09 – – – 20 1.86 1.01 .95 .90 .77 .72 .67 .62 .56 30 2.42 .88 .84 .81 .75 .71 .67 .63 .57 40 2.96 .76 .73 .69 .65 .61 .58 .53 .48 60 4.05 .44 .41 .37 .33 .30 .27 – 20 2.26 1.35 1.28 1.20 1.01 .96 .92 .78 30 2.88 1.26 1.21 1.14 .92 .87 .82 .74 .59 40 3.52 .98 .92 .87 .66 .59 .52 .44 – 50 4.13 .58 .52 .44 – – – – 20 2.10 2.01 1.90 1.71 1.47 1.40 1.32 30 2.70 2.00 1.94 1.81 1.58 1.52 40 3.28 1.82 1.74 1.63 1.42 50 3.87 1.10 .97 .85 .69 Air Press. Gravity Head (in.) Siphon Height (in.) Air* A (in.) B (in.) C (in.) D (ft.) 10 20 30 8 8-1/2 9 10-1/2 11-1/2 12 15 15 15 7 7 6 – 20 30 40 60 9 9-1/2 10-1/2 11 12-1/2 15 13-1/2 16-1/2 14-1/2 18 15-1/2 19 .62 20 7-1/2 9 10-1/2 11 30 8 10 11 11 – 40 8-1/2 10-1/2 12 10 1.17 .92 20 6-1/2 8-1/2 10-1/2 11 1.45 1.34 1.11 1.34 1.22 1.03 – 30 7 9 11-1/2 11 – – – – 40 8 10-1/2 13 11 9 9 10 9 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F23 Air Atomizing Nozzles Siphon/Gravity-Fed Spray Set-ups, External Mix, 1/8J and 1/4J Series Performance Data Round Spray Spray Set-up No. SU1A SU1 SU2A SU2 SU4 SU5 Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap 1650 + Air Cap 64 Fluid Cap 2050 + Air Cap 64 Fluid Cap 2050 + Air Cap 70 Fluid Cap 2850 + Air Cap 70 Fluid Cap 60100 + Air Cap 120 Fluid Cap 100150 + Air Cap 180 *At the stated pressure in psi. Atomizing Air Liquid Capacity (gallons per hour)* Spray Dimensions at 8" Siphon Height Air Press. Air Capacity scfm 18 12 6 4 8 12 10.0 .40 .39 .35 .30 .23 .18 20 .59 .46 .43 .39 .34 .31 40 .95 .54 .50 .47 .41 Gravity Head (in.) Siphon Height (in.) Air* Spray Angle A (°) B (in.) D (ft.) 24 36 .14 – – 10 18 11 6 .28 .14 – 20 18 11 6-1/2 .38 .36 .28 .19 40 18 12 7-1/2 8-1/2 60 1.32 .59 .54 .49 .44 .41 .39 .31 .24 60 18 14 10.0 .47 .63 .55 .46 .40 .32 .21 – – 10 18 12 7 20 .66 .73 .66 .60 .54 .48 .40 .21 .07 20 18 13 7-1/2 40 1.06 .87 .81 .76 .71 .67 .61 .43 .28 40 18 15 8-1/2 60 1.48 .98 .92 .88 .83 .79 .73 .57 .40 60 19 17 10 10.0 .81 .67 .61 .53 .43 .37 .29 – – 10 18 12 8 20 1.20 .76 .72 .64 .56 .50 .44 .21 – 20 18 13 9 40 1.94 .89 .86 .82 .76 .71 .65 .46 .30 40 19 15 11 60 2.70 .98 .96 .94 .91 .87 .81 .68 .56 60 20 17 13 10.0 .68 1.19 1.05 .91 .56 .47 .38 – – 10 21 15 10 20 1.03 1.37 1.27 1.13 .88 .77 .68 .46 – 20 21 16 11 40 1.70 1.57 1.47 1.32 1.15 1.05 .91 .63 .28 40 21 18 13 60 2.39 1.48 1.41 1.30 1.08 1.02 .90 .74 .52 60 22 20 15 20 1.90 5.80 5.15 4.20 3.10 2.65 1.90 .60 – 20 17 18 12 40 3.00 6.50 5.95 5.10 4.30 3.70 3.00 1.55 .70 40 18 20 14 60 4.10 6.80 6.35 5.60 4.90 4.20 3.45 2.20 1.30 60 18 21 16 80 5.20 6.80 6.40 5.80 5.20 4.50 3.85 2.60 1.60 80 19 23 18 30 5.3 – – – 7.2 6.0 4.6 – – 30 20 20 22 40 6.5 – – – 7.8 6.8 5.3 – – 40 20 21 23 60 8.8 – 11.4 10.6 8.3 7.4 6.2 3.2 – 60 21 23 25 80 11.1 11.6 11.0 10.3 8.3 7.5 6.4 4.4 2.2 80 22 25 27 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F24 Overview, 1/8JJ Compact Series 1/8JJ Series air atomizing Spray set-up 1/8JJ 1 2 3 4 5 Spray set-up 1/8JJCO Clean-out needle assembly 14471 1 2 3 4 7 6 1/8JJN 1. Retainer ring CP12582 2. Air cap 3. Fluid cap 4. O-ring 7717-2/007 5. Nozzle body CP12891 6. Nozzle body CP14468 7. Back Seal Gasket 7222-BUC Shut-off needle assembly 14486 1/8JJAU – Drip Free Shut-off/clean-out needle assembly Applying lubricant to form presses in steel drum manufacturing. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F25 Air Atomizing Nozzles Spray Set-up for Drip Free™ Air Atomizing Nozzles Nozzle Bodies/Nozzle Assemblies, 1/8JJ Compact Series Features and Benefits Optimization Tips • Nozzle assembly consists of a body and spray set-up. • See page F2 for optimization tips. • Various assemblies can be added to provide shut-off or clean-out functions. See Also • 1/8JJ has liquid and air feeds at opposite ends of the body. • 1/8JJN features a manual shut-off needle that enables the flow of liquid to be stopped. • Accessories – Air line filters • 1/8JJCO features a clean-out needle that is activated manually. – Needle slides through the liquid orifice to clear obstructions. – Ideal for intermittent spraying applications when liquid can dry in the orifice between uses. 1/8JJ 1/8JJN 1/8" NPT or BSPT Material – Pressure gauges – Air pressure regulators – Solenoid valves – Liquid pressure regulators – Strainers 1/8JJCO 1/8" NPT or BSPT with shut-off needle Materials http:// 1/8" NPT or BSPT with clean-out needle Ordering Info Complete Nozzle Assembly Nozzle Type Material Code JJ JJN JJCO Nozzle Body* Spray Set-up Only Spray Set-up Spray Set-up 1/8 JJN – SS + SUJ12A – SS Nozzle Bodies Electroless Nickelplated Brass (none) l l l 303 Stainless Steel SS l l l Spray Set-ups l l l l l Inlet Conn. Nozzle Body Assembly Type Material Code Spray Set-up No. Material Code *Includes retainer and gasket. Electroless Nickelplated Brass Air Cap and 303 Stainless Steel Fluid Cap SSBR 303 Stainless Steel SS l l l BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. SUJ12A l Spray Set-up No. – SS l Material Code To order spray set-up only, use spray set-up number and material code: SU12A-SS. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: J2050-SS. l l l To order air cap only, use air cap number (shown in performance data charts) and material code: J73160-SS. To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1/8JJN-SS. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F26 Pressure Spray Set-ups, Internal Mix, 1/8JJ Compact Series Features and Benefits Air Caps • For round spray pattern, angle “A” is maintained throughout distance “B”. Beyond “B”, the spray becomes turbulent and will project out to distance “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Round spray and 360° circular spray air caps produce full cone round spray; air caps used in spray set-up SUJ340C produce 360° circular spray pattern. Round spray pattern A B D 12582 retainer ring and 7717-2/007 O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Round Spray Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination SUJ11 Fluid Cap J2050 + Air Cap J67147 SUJ12A Fluid Cap J2050 + Air Cap J73160 Air Atomizing Nozzles Performance Data *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air* Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. Liquid* Spray Angle A (°) B (in.) D (ft.) 10.0 .66 .55 14 1.50 .40 24 1.68 .56 32 1.86 .68 50 2.28 .98 12 10 13 12 9 12.0 .48 .67 18 1.23 .50 28 1.44 .63 36 1.62 .80 54 2.05 1.07 24 20 13 13 10 14.0 .36 .78 22 .99 .63 32 1.08 .82 40 1.32 .93 58 1.80 1.19 36 30 13 14 11 40 14 15-1/2 12-1/2 – – – 26 .72 .76 38 .72 1.03 48 .85 1.23 66 1.32 1.52 44 – – – 30 .45 .93 42 .54 1.19 52 .66 1.38 70 1.11 1.66 62 60 15 17-1/2 14-1/2 10.0 .66 .66 18 1.44 .87 24 1.98 1.00 30 2.40 1.14 40 3.30 1.36 12 10 12 17 12 12.0 .54 .77 20 1.32 .98 28 1.68 1.17 34 2.16 1.29 46 2.94 1.54 20 20 13 18 13 14.0 .42 .90 22 1.20 1.06 32 1.44 1.35 38 1.92 1.47 52 2.58 1.83 34 30 13 19 14 – – – 26 .90 1.26 36 1.20 1.57 44 1.50 1.78 62 2.10 2.26 42 40 13 20 15 – – – – – – 40 1.02 1.76 48 1.32 1.98 70 1.68 2.67 58 60 15 22 17 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F27 Air Atomizing Nozzles Pressure Spray Set-ups, Internal Mix, 1/8JJ Compact Series Performance Data Round Spray Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination SUJ12 Fluid Cap J2850 + Air Cap J73160 SUJ22B SUJ22 Fluid Cap J40100 + Air Cap J1401110 Fluid Cap J60100 + Air Cap J1401110 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* 10 20 30 40 60 Air* Liquid* Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. Spray Set-up No. SUJ340C Fluid Cap J60100 + Air Cap J150-6-62160HC Spray Angle A (°) B (in.) D (ft.) 12.0 1.26 .73 22 2.16 1.05 30 2.90 1.24 36 4.32 1.26 48 5.82 1.50 22 10 12 19 13 16.0 1.08 .94 26 1.74 1.26 34 2.46 1.42 40 3.85 1.36 52 5.28 1.65 34 20 13 20 14 20 .90 1.15 30 1.44 1.47 38 2.10 1.65 44 3.55 1.56 56 4.92 1.73 42 30 13 21 15 24 .78 1.36 38 1.08 1.87 46 1.50 2.03 52 2.46 2.01 64 4.08 2.08 48 40 14 22 16 60 15 23-1/2 17-1/2 1.56 42 .94 2.04 52 1.20 2.36 60 1.86 2.36 70 3.60 2.34 60 16.0 3.44 2.68 28 5.03 3.71 40 6.10 4.72 48 7.75 5.30 65 10.70 6.74 24 10 18 26 16 20 2.35 3.20 32 3.70 4.17 44 5.03 5.17 55 5.95 6.07 75 8.67 7.73 40 20 20 30 20 22 1.90 3.46 36 2.64 4.65 48 3.95 5.65 65 3.55 7.28 80 7.65 8.25 55 30 20 32 22 40 21 36 26 28 .76 26 1.23 3.97 44 1.30 5.63 60 1.56 7.12 80 1.40 9.10 90 5.64 9.40 75 30 .72 4.48 50 .76 6.36 70 .73 8.35 90 .72 10.34 100 3.62 10.60 85 60 21 38 30 12.0 8.1 2.00 20 13.6 2.55 30 16.3 3.25 38 19.5 3.74 54 25.7 4.66 14 10 17 24 16 14.0 6.6 2.32 22 12.0 2.85 34 13.1 3.75 42 16.5 4.20 60 21.8 5.34 26 20 18 27 19 16.0 4.9 2.66 24 10.2 3.15 38 9.9 4.32 46 13.6 4.71 65 18.5 5.98 40 30 20 30 22 – – – 28 7.2 3.75 42 7.6 4.90 52 9.6 5.58 75 12.2 7.80 50 40 20 31 23 – – – 32 4.6 4.35 46 5.6 5.50 56 7.6 6.14 85 8.0 70 60 21 36 28 360° Circular Spray† Spray Set-up Consists of Fluid and Air Cap Combination Spray Dimensions Liquid Pressure 8.90 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Liquid Pressure 10 20 30 40 60 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. 20 4.0 2.45 34 6.6 4.09 50 7.1 6.38 60 11.0 7.6 85 14.4 11.8 22 24 2.8 2.7 38 4.4 4.8 52 6.2 6.75 65 8.3 8.63 90 12.0 13.0 2.0 2.97 42 2.8 5.5 56 4.4 7.55 70 6.1 9.78 95 9.8 14.1 26 1.5 3.3 46 1.7 6.34 60 3.2 8.41 80 3.1 12.44 100 7.8 15.4 28 1.1 3.62 48 1.3 6.85 70 1.3 11.75 90 1.4 – – – 15.4 360° circular spray pattern †Use only with 1/8JJAU automatic air atomizing nozzles. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F28 Pressure Spray Set-ups, Internal Mix, 1/8JJ Compact Series Features and Benefits Air Caps • For wide angle round and flat sprays, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. Wide angle round and flat spray air caps produce hollow cone type, wide angle round spray and flat spray patterns. • The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. C B A Wide angle round spray pattern 6" (15 cm) 9" (23 cm) 15" (38 cm) D Air Atomizing Nozzles 12582 retainer ring and 7717-2/007 O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Wide Angle Round Spray Spray Set-up No. SUJ16 Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap J2050 + Air Cap J67-6-20-70° Fluid Cap J40100 SUJ26B + Air Cap J140-6-37-70° Fluid Cap J60100 SUJ26 + Air Cap J140-6-37-70° Fluid Cap J60100 SUJ29 + Air Cap J140-6-52-70° Fluid Cap J40100 SUJ30 + Air Cap J120-6-35-60° *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) 8.0 10.0 12.0 14.0 – 12.0 14.0 – – – 10.0 12.0 14.0 – – 18.0 22 26 30 34 16.0 18.0 20 24 28 1.41 1.14 .79 .45 – 1.85 .55 – – – 6.3 3.6 2.0 – – 9.4 7.7 6.0 4.4 3.0 3.24 2.61 2.08 1.30 .82 .36 .43 .50 .60 – 1.78 2.20 – – – 1.14 1.54 2.00 – – 3.0 3.6 4.13 4.7 5.25 1.43 1.59 1.75 2.06 2.35 14.0 16.0 18.0 22 26 22 24 26 – – 20 22 24 26 – 30 34 38 46 60 28 32 36 42 46 2.10 1.90 1.68 1.17 .55 3.30 2.20 1.20 – – 9.0 6.9 5.1 3.3 – 13.4 11.9 10.3 7.3 2.4 4.60 3.37 2.45 1.45 1.0 .42 .50 .56 .71 .90 2.30 2.67 3.05 – – 1.60 2.00 2.40 2.80 – 4.15 4.65 5.1 6.1 7.95 1.96 2.27 2.55 3.00 3.28 22 26 30 36 40 30 32 36 40 – 30 32 36 40 – 44 48 55 70 80 42 46 48 55 65 2.36 2.02 1.61 .91 .43 5.10 4.25 2.50 .70 – 11.2 9.3 5.4 2.3 – 15.3 13.8 11.3 6.1 3.3 5.27 4.0 3.45 2.11 1.03 .56 .69 .83 1.07 1.25 2.54 2.85 3.50 4.30 – 2.04 2.44 3.20 3.98 – 5.45 5.9 6.75 8.6 9.85 2.67 2.96 3.11 3.63 4.36 30 34 38 46 50 38 42 46 50 52 40 42 46 50 52 60 70 80 90 100 55 60 65 75 85 2.53 2.23 1.90 1.10 .69 6.40 4.70 3.06 1.40 .60 12.4 10.6 7.1 3.6 2.2 15.6 12.5 9.3 6.2 3.7 5.69 4.24 3.15 1.72 1.05 .68 .81 .94 1.26 1.45 2.84 3.42 4.05 4.84 5.34 2.54 2.92 3.72 4.51 4.91 7.05 8.25 9.45 10.7 11.9 3.30 3.68 4.06 4.82 5.58 44 48 55 65 75 54 56 60 70 75 56 58 65 75 80 80 85 90 100 – 80 85 90 100 – 2.95 2.72 2.30 1.50 .65 8.76 8.10 6.76 3.50 1.85 16.2 14.8 9.8 4.0 2.4 21.4 19.5 17.9 15.1 – 7.10 5.80 4.65 3.00 – .81 .94 1.20 1.60 2.05 3.44 3.74 4.32 6.00 6.95 2.75 3.11 4.42 6.31 6.51 8.55 9.15 9.75 10.95 – 4.50 4.88 5.27 6.03 – B (in.) C (in.) D (ft.) 10 20 34 42 60 10 20 30 40 60 5-1/2 7 9 6 7-1/2 9-1/2 6-1/2 8 10 6-1/2 8 10-1/2 7-1/2 9 12 12 24 34 46 60 10 20 30 40 60 7 9-1/2 12-1/2 6 7-1/2 10 13 8 7-1/2 10 13 10-1/2 8 10-1/2 13-1/2 13-1/2 8-1/2 11 14-1/2 19-1/2 12 22 34 46 65 10 20 30 40 60 7-1/2 10 14 7 8 10-1/2 14-1/2 10-1/2 8 10-1/2 14-1/2 13-1/2 8 11 15 16-1/2 8 11 15-1/2 22-1/2 28 42 65 85 90 10 20 30 40 60 8 10 13 8 10-1/2 13-1/2 8-1/2 11 14-1/2 9 11-1/2 15 9-1/2 12-1/2 16 18 21 27 30 34 22 40 50 70 90 10 20 30 40 60 6 7-1/2 6-1/2 8 6-1/2 8 7 8-1/2 7-1/2 9-1/2 9 15 18 24 31 9 9-1/2 9-1/2 10 11 5 6 7 9 13 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F29 Air Atomizing Nozzles Pressure Spray Set-ups, Internal Mix, 1/8JJ Compact Series Performance Data Flat Spray Spray Set-up No. SUJ13A SUJ13 SUJ14 SUJ23B SUJ23 Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap J2050 + Air Cap J73328 Fluid Cap J2850 + Air Cap J73328 Fluid Cap J2850 + Air Cap J73320 Fluid Cap J40100 + Air Cap J125328 Fluid Cap J60100 + Air Cap J125328 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. A (in.) B (in.) C (in.) D (ft.) 8-1/2 10.0 1.44 .84 18.0 2.17 1.12 28 2.49 1.47 38 2.77 1.84 55 3.41 2.43 16 10 10 14 18 12.0 1.25 .96 22 1.82 1.31 32 2.19 1.64 42 2.49 2.01 65 2.83 2.85 30 20 14 19 26 10 14.0 1.09 1.08 26 1.50 1.50 36 1.89 1.82 46 2.20 2.19 75 2.26 3.26 40 30 15 21 30 10-1/2 18.0 .79 1.32 34 .93 1.87 44 1.30 2.18 60 1.25 2.81 90 1.40 3.88 50 40 18-1/2 24 34 11 22 .53 1.55 40 .57 2.16 55 .65 2.68 70 .65 3.25 100 .88 4.29 85 60 22 29 37 13 12.0 2.17 .70 20 3.35 .96 30 3.98 1.27 38 4.66 1.49 65 4.8 2.38 16 10 14 18 28 7 14.0 1.80 .82 24 2.71 1.14 34 3.41 1.45 42 4.14 1.65 70 4.21 2.62 30 20 17 24 32 8 16.0 1.45 .95 28 2.06 1.34 38 2.85 1.64 46 3.6 1.85 75 3.63 2.86 42 30 20 26 35 8-1/2 20 .77 1.2 32 1.44 1.56 46 1.72 2.07 60 1.76 2.58 85 2.48 3.35 50 40 23 30 38 9 – – – 36 .94 1.78 50 1.2 2.28 70 .76 3.09 95 1.57 3.85 80 60 23 30 38 10-1/2 18.0 1.04 1.05 30 1.56 1.43 42 2.06 1.75 55 2.16 2.15 75 3.20 2.66 22 10 10 13 18 6 20 .80 1.15 34 1.10 1.61 44 1.80 1.85 60 1.60 2.38 80 2.66 2.90 38 20 14 20 27 6-1/2 22 .62 1.25 36 .90 1.70 46 1.57 1.94 65 1.15 2.62 85 2.19 3.13 46 30 23 29 36 6-1/2 26 .35 1.45 40 .60 1.88 50 1.13 2.13 – – – – – – 60 40 24 29 37 7 – – – 44 .35 2.07 – – – – – – – 80 60 25 30 38 7-1/2 – – 16.0 2.95 1.92 28 4.45 2.66 38 5.94 3.22 46 7.50 3.66 65 9.70 4.80 20 10 6 7 8 10 18.0 2.25 2.10 30 3.87 2.84 40 5.40 3.40 50 6.45 3.97 70 8.60 5.20 32 20 9 11 13 10-1/2 20 1.72 2.30 32 3.30 3.04 42 4.86 3.55 52 5.90 4.15 75 7.50 5.60 42 30 10 13 18 11 24 1.00 2.70 36 2.28 3.40 46 3.78 3.93 56 4.87 4.50 85 5.30 6.48 54 40 12 15 18 11-1/2 60 3.84 4.90 – 75 60 13 16 19 13 – – – – – – – – – – – 12.0 7.0 1.15 22 11.5 1.65 34 12.4 2.20 46 13.7 2.75 65 18.3 3.56 16 10 7 9 12 11 14.0 5.4 1.35 26 8.3 2.02 38 9.8 2.57 50 10.9 3.14 75 12.6 4.47 32 20 9 12 16 11-1/2 16.0 4.2 1.57 30 6.0 2.40 42 7.8 2.95 54 8.7 3.51 80 10.6 4.95 46 30 10 13 17 12 20 2.7 1.97 34 4.3 2.78 48 5.0 3.52 60 6.4 4.06 90 6.9 5.85 56 40 12 15 19 12-1/2 – – – 38 3.0 3.16 52 3.7 3.90 70 3.3 5.00 100 4.5 6.76 85 60 13 16 20 14-1/2 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F30 Pressure Spray Set-ups, External Mix, High Capacity, 1/8JJ Compact Series Features and Benefits • Offers an increased ability to atomize viscous fluids and allows for greater capacities of finely atomized sprays. • The liquid and compressed air or gas are mixed externally to produce a completely atomized spray. • Simple, one-piece, low-profile design permits larger air passage. More air can be brought in to atomize the liquid stream. • SUJE Spray Set-up Series is both compact and air efficient. • Atomization can be controlled by varying the air pressure without changing liquid flow rates. • SUJE Series features lower spray velocity for improved transfer and reduced misting and is ideal for applications where space is limited. • Offered in three spray angles – 50°, 65° and 90°. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • Very efficient use of air results in reduced air consumption costs and noise levels. C B CP46259 retainer ring and CP7717-2/007-VI O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. The 46599 adapter is used with all 1/8JJ nozzle bodies and automatic spray guns with extensions, but not on 1/8JJAU spray guns without extensions. Please contact your sales engineer. A Flat spray pattern External mix air caps produce a flat spray pattern. 6" (15 cm) 9" (23 cm) 15" (38 cm) D Performance Data Flat Spray (External Mix) Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination SUJE416-50 Fluid Cap PFJ1650 + Air Cap PAJ105-50 SUJE417-50 Fluid Cap PFJ2050 + Air Cap PAJ105-50 SUJE418-50 Fluid Cap PFJ2850 + Air Cap PAJ105-50 SUJE420-50 Fluid Cap PFJ40100 + Air Cap PAJ135-50 SUJE421-50 Fluid Cap PFJ60100 + Air Cap PAJ135-50 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Liquid Pressure 10 Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 30 40 50 60 70 20 gph scfm 1.3 1.3 1.3 1.3 1.3 1.9 1.9 1.9 1.9 1.9 2.9 2.9 2.9 2.9 2.9 8.0 8.0 8.0 8.0 8.0 – – – – – 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.1 7.3 – – – – – Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 30 40 50 60 70 30 gph scfm 1.8 1.8 1.8 1.8 1.8 2.6 2.6 2.6 2.6 2.6 5.8 5.8 5.8 5.8 5.8 11.7 11.7 11.7 11.7 11.7 – – – – – 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.1 7.3 – – – – – Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 30 40 50 60 70 Spray Angle 40 gph scfm 2.2 2.2 2.2 2.2 2.2 3.2 3.2 3.2 3.2 3.2 7.9 7.9 7.9 7.9 7.9 14.4 14.4 14.4 14.4 14.4 – – – – – 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.1 7.3 – – – – – Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 30 40 50 60 70 gph scfm 2.6 2.6 2.6 2.6 2.6 – – 4.0 4.0 4.0 8.3 8.3 8.3 8.3 8.3 16.7 16.7 16.7 16.7 16.7 – – – 33.2 33.2 2.3 3.7 5.0 6.2 7.4 – – 5.0 6.2 7.4 2.3 3.7 5.0 6.2 7.4 2.3 3.7 5.0 6.1 7.3 – – – 8.5 9.7 50° Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F31 Air Atomizing Nozzles • Simple four-part assembly allows easy installation and maintenance. Air Caps Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, High Capacity, 1/8JJ Compact Series Performance Data Flat Spray (External Mix) Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination SUJE416-65 Fluid Cap PFJ1650 + Air Cap PAJ080-65 SUJE417-65 Fluid Cap PFJ2050 + Air Cap PAJ080-65 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Liquid Pressure 10 Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 20 gph scfm 1.3 1.3 1.3 1.3 1.3 1.9 1.9 1.9 1.9 1.9 2.9 2.9 2.9 2.9 2.9 8.0 8.0 8.0 8.0 8.0 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 2.1 3.3 4.4 5.4 6.5 Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 30 gph scfm 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 2.1 3.3 4.4 5.4 6.5 Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 2.2 2.2 2.2 2.2 2.2 3.2 3.2 3.2 3.2 3.2 – 7.9 7.9 7.9 7.9 14.4 14.4 14.4 14.4 14.4 gph scfm 1.8 1.8 1.8 1.8 1.8 2.6 2.6 2.6 2.6 2.6 5.8 5.8 5.8 5.8 5.8 11.7 11.7 11.7 11.7 11.7 Spray Angle 40 gph scfm 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 – 3.0 4.0 5.0 5.9 2.1 3.3 4.4 5.4 6.5 Air Press. 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 2.6 2.6 2.6 2.6 2.6 4.0 4.0 4.0 4.0 4.0 – – 8.3 8.3 8.3 16.7 16.7 16.7 16.7 16.7 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 – – 4.0 5.0 5.9 2.1 3.3 4.4 5.4 6.5 SUJE418-65 Fluid Cap PFJ2850 + Air Cap PAJ080-65 SUJE420-65 Fluid Cap PFJ40100 + Air Cap PAJ125-65 30 16.0 4.4 30 – – 30 – – 30 – – SUJE421-65 Fluid Cap PFJ60100 + Air Cap PAJ125-65 40 16.0 5.4 40 23.2 5.4 40 – – 40 – – 50 16.0 6.5 50 23.2 6.5 50 28.7 6.5 50 – – SUJE416-90 Fluid Cap PFJ1650 + Air Cap PAJ075-90 SUJE417-90 Fluid Cap PFJ2050 + Air Cap PAJ075-90 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 20 30 40 50 30 40 50 60 70 1.3 1.3 1.3 1.3 1.3 1.9 1.9 1.9 1.9 1.9 2.9 2.9 2.9 2.9 2.9 8.0 8.0 8.0 8.0 16.0 16.0 16.0 – – 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 2.9 3.9 4.8 5.7 3.9 4.8 5.7 – – 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 20 30 40 50 30 40 50 60 70 1.8 1.8 1.8 1.8 1.8 2.6 2.6 2.6 2.6 2.6 – 5.8 5.8 5.8 5.8 – 11.7 11.7 11.7 – 23.2 23.2 – – 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 – 3.0 4.0 5.0 5.9 – 3.9 4.8 5.7 – 4.8 5.7 – – 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 20 30 40 50 30 40 50 60 70 2.2 2.2 2.2 2.2 2.2 3.2 3.2 3.2 3.2 3.2 – 7.9 7.9 7.9 7.9 – – 14.4 14.4 – – 28.7 – – 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 – 3.0 4.0 5.0 5.9 – – 4.8 5.7 – – 5.7 – – 10.0 20 30 40 50 10.0 20 30 40 50 10.0 20 30 40 50 20 30 40 50 30 40 50 60 70 2.6 2.6 2.6 2.6 2.6 4.0 4.0 4.0 4.0 4.0 – – 8.3 8.3 8.3 – – – 16.7 – – – 33.2 33.2 1.9 3.0 4.0 5.0 5.9 1.9 3.0 4.0 5.0 5.9 – – 4.0 5.0 5.9 – – – 5.7 – – – 6.6 7.5 SUJE418-90 Fluid Cap PFJ2850 + Air Cap PAJ075-90 SUJE420-90 Fluid Cap PFJ40100 + Air Cap PAJ115-90 SUJE421-90 Fluid Cap PFJ60100 + Air Cap PAJ115-90 65° 90° Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F32 Pressure Spray Set-ups, Internal Mix, Air Efficient, 1/8JJ Compact Series Air Caps Elliptical spray pattern Internal mix air caps produce an elliptical spray pattern. A D Performance Data Elliptical Spray/Air Efficient (Internal Mix) SUJ400 SUJ401 Fluid Cap PFJ16225 + Air Cap PAJ14739 Fluid Cap PFJ20232 + Air Cap PAJ132-50 Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 15 20 25 30 35 40 Spray D Air* Liquid* Angle Air Air Air Air Air Air (in.) gph scfm gph scfm gph scfm gph scfm gph scfm gph scfm A (°) Press. Press. Press. Press. Press. Press. – – – – – – – – – – – – 60 .13 1.1 60 .38 1.1 – – – – – – – – – 50 .17 .93 50 .60 .88 50 .88 .85 – – – – – – 40 .18 .75 40 .71 .72 40 1.1 .68 40 1.4 .66 – – – – – – 35 .55 .63 35 1.1 .59 35 1.4 .56 35 1.2 .53 10 10 35 24 – – – 30 .45 .56 30 .92 .51 30 1.3 .48 30 1.6 .46 30 1.9 .45 20 20 30 30 25 .30 .60 25 .80 .46 25 1.2 .43 25 1.5 .41 25 1.8 .39 25 2.1 .37 20 .69 .40 20 1.1 .38 20 1.4 .36 20 1.7 .34 20 1.9 .33 20 2.2 .30 15.0 .94 .33 15.0 1.5 .30 15.0 1.7 .27 15.0 1.9 .25 15.0 2.2 .23 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 50 1.1 1.4 – – – – – – – – – 40 0.7 1.2 40 1.2 1.1 40 1.8 1.0 – – – – – – 30 1.1 .88 30 1.7 .82 30 2.1 .77 30 2.6 .71 10 10 35 26 – – – 25 1.0 .59 25 1.6 .70 25 2.1 .64 25 2.6 .60 25 3.0 .56 20 20 25 32 20 .85 .64 20 1.5 .56 20 2.0 .54 20 2.5 .50 20 2.8 .49 20 3.2 .48 15.0 1.3 .47 15.0 1.9 .43 15.0 2.4 .40 15.0 2.9 .36 15.0 3.2 .34 15.0 3.5 .32 10.0 1.9 .32 10.0 2.3 .30 10.0 2.7 .28 10.0 3.2 .25 10.0 3.5 .23 10.0 3.8 .22 Tabulation is based on spraying air and water at room temperature under laboratory conditions. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F33 Air Atomizing Nozzles Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination *At the stated pressure in psi. Air Atomizing Nozzles Siphon/Gravity-Fed Spray Set-ups, External Mix, 1/8JJ Compact Series Features and Benefits Air Caps • For round spray pattern, angle “A” is maintained throughout distance “B”. Beyond “B”, the spray becomes turbulent and will project out to distance “D”. • When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed. Round spray air caps produce a full cone round spray pattern. • Designed to draw liquid through the feed line into the air flow where it is atomized. Round spray pattern A B D 12582 retainer ring and 7717-2/007 O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Round Spray Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination SUJ1A Fluid Cap J1650 + Air Cap J64 SUJ1 Fluid Cap J2050 + Air Cap J64 SUJ2A Fluid Cap J2050 + Air Cap J70 SUJ2 Fluid Cap J2850 + Air Cap J70 SUJ3 Fluid Cap J2850 + Air Cap J64-5 SUJ4B Fluid Cap J40100 + Air Cap J120 SUJ4 Fluid Cap J60100 + Air Cap J120 *At the stated pressure in psi. Atomizing Air Liquid Capacity (gallons per hour)* Air Press. Air Capacity scfm Gravity Head (in.) 18 12 6 4 10.0 20 40 60 10.0 20 40 60 10.0 20 40 60 10.0 20 40 60 10.0 20 40 60 10.0 20 40 60 20 40 60 80 .40 .59 .95 1.32 .47 .66 1.06 1.48 .81 1.20 1.94 2.70 .68 1.03 1.70 2.39 .41 .61 .99 1.36 1.30 1.97 3.12 4.28 1.90 3.00 4.10 5.20 .39 .46 .54 .59 .63 .73 .87 .98 .67 .76 .89 .98 1.19 1.37 1.48 1.57 – – 1.68 1.91 – – 3.20 3.47 5.80 6.50 6.80 6.80 .35 .43 .50 .54 .55 .66 .81 .92 .61 .72 .86 .96 1.05 1.27 1.41 1.47 – 1.22 1.56 1.81 – 2.57 2.96 3.24 5.15 5.95 6.35 6.40 .30 .39 .47 .49 .46 .60 .76 .88 .53 .64 .82 .94 .91 1.13 1.30 1.32 – 1.05 1.45 1.72 – 2.37 2.80 3.05 4.20 5.10 5.60 5.80 .23 .34 .41 .44 .40 .54 .71 .83 .43 .56 .76 .91 .56 .88 1.08 1.15 .59 .89 1.34 1.64 1.40 1.90 2.30 2.57 3.10 4.30 4.90 5.20 Spray Set-up No. Siphon Height (in.) Spray Set-up 8 12 24 No. 36 .18 .31 .38 .41 .32 .48 .67 .79 .37 .50 .71 .87 .47 .77 1.02 1.05 .49 .78 1.22 1.54 .97 1.50 2.02 2.32 2.65 3.70 4.20 4.50 .14 .28 .36 .39 .21 .40 .61 .73 .29 .44 .65 .81 .38 .68 .90 .91 .29 .63 1.10 1.44 .59 1.20 1.70 2.05 1.90 3.00 3.45 3.85 – SUJ1A– .14 – .28 .19 .31 .24 – SUJ1– .21 .07 .43 .28 .57 .40 – SUJ2A– .21 – .46 .30 .68 .56 – SUJ2– .46 – .63 .28 .74 .52 – SUJ3– .26 – .70 .30 1.02 .56 – SUJ4B– .34 – .76 .26 1.16 .52 .60 SUJ4– 1.55 .70 2.20 1.30 2.60 1.60 Spray Dimensions at 8" Siphon Height Air* Spray Angle A (°) B (in.) D (ft.) 10 20 40 60 18 18 18 18 11 11 12 14 6 6-1/2 7-1/2 8-1/2 10 20 40 60 18 18 18 19 12 13 15 17 7 7-1/2 8-1/2 10 10 20 40 60 18 18 19 20 12 13 15 17 8 9 11 13 10 20 40 60 21 21 21 22 15 16 18 20 10 11 13 15 10 20 40 60 18 18 18 19 12 13 15 17 8 9 11 13 10 20 40 60 17 17 18 19 18 19 21 23 10 11 13 15 20 40 60 80 17 18 18 19 18 20 21 23 12 14 16 18 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F34 Siphon/Gravity-Fed Spray Set-ups, External Mix, 1/8JJ Compact Series Features and Benefits Air Caps • For flat spray pattern, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. • Total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. C Flat spray air caps produce a flat spray pattern. B A Flat spray pattern 6" (15 cm) 9" (23 cm) 15" (38 cm) D Performance Data Flat Spray SUJF1 Fluid Cap J2850 + Air Cap J73420 Fluid Cap J35100 SUJF2C + Air Cap J120432 Fluid Cap J40100 SUJF3B + Air Cap J122435 Fluid Cap J40100 SUJF4B + Air Cap J122440 *At the stated pressure in psi. Atomizing Air Liquid Capacity (gallons per hour)* Air Capacity scfm 18 12 6 4 8 12 24 36 10.0 .99 .35 .33 .30 .27 .25 .22 .17 .13 20 1.42 .31 .30 .29 .26 .25 .23 .19 .16 30 1.83 .18 .16 .15 .11 .09 – – – 20 1.86 1.01 .95 .90 .77 .72 .67 .62 .56 30 2.42 .88 .84 .81 .75 .71 .67 .63 .57 40 2.96 .76 .73 .69 .65 .61 .58 .53 .48 60 4.05 .44 .41 .37 .33 .30 .27 – – 20 2.26 1.35 1.28 1.20 1.01 .96 .92 .78 .62 30 2.88 1.26 1.21 1.14 .92 .87 .82 .74 .59 40 3.52 .98 .92 .87 .66 .59 .52 .44 – 50 4.13 .58 .52 .44 – – – – – 20 2.10 2.01 1.90 1.71 1.47 1.40 1.32 1.17 .92 30 2.70 2.00 1.94 1.81 1.58 1.52 1.45 1.34 1.11 40 3.28 1.82 1.74 1.63 1.42 1.34 1.22 1.03 – 50 3.87 1.10 .97 .85 .69 – – – – Air Press. Gravity Head (in.) Spray Dimensions at 8" Siphon Height Siphon Height (in.) A (in.) B (in.) C (in.) D (ft.) 10 8 10-1/2 15 7 20 8-1/2 11-1/2 15 7 30 9 12 15 6 20 30 40 60 9 9-1/2 10-1/2 11 12-1/2 13-1/2 14-1/2 15-1/2 15 16-1/2 18 19 9 9 10 9 20 7-1/2 9 10-1/2 11 30 8 10 11 11 40 8-1/2 10-1/2 12 10 20 6-1/2 8-1/2 10-1/2 11 30 7 9 11-1/2 11 40 8 10-1/2 13 11 Air* Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F35 Air Atomizing Nozzles Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination Air Atomizing Nozzles Overview/Nozzle Bodies/Nozzle Assemblies, VAU and VMAU Series Variable Spray Series air atomizing nozzles 1/8VAA Plug 29155-001-SS Spray set-up 1/8VAAN Shut-off needle assembly 29535-001-SS 1/8VAACO 1 1/8VAANCO 2 3 4 5 1. Cap ring 28207-101-SS 2. Air cap 3. Fluid cap 4. Nozzle body 29074-001-SS 5. Washer 29154-001-BUC Clean-out needle assembly 29156 Shut-off/clean-out needle assembly 29534 1/8VAU Features and Benefits • The VAA, VAU and VMAU variable spray nozzles provide uniform spray distribution, even when spraying viscous liquids. • VAACO features a clean-out needle that clears the liquid orifice of obstructions when activated manually. • Independent control of liquid, atomizing air, and fan air pressures is possible for fine-tuning of flow rate, drop size, spray distribution and coverage. • VAANCO combines the features of the VAAN and VAACO, offering a combination shut-off/clean-out needle. • Can be set and re-set in seconds, simplifying application changes. • VAU offers automatic operation with a built-in shut-off/clean-out needle. • Independent air atomizing line can be adjusted to vary spray drop size without affecting liquid flow rates. • VAUPM has the same operating features as the VAU, but offers the convenience of a mounting plate. • Additional inlet/outlet port allows for liquid recirculation that effectively maintains the flow of viscous liquids. • VMAU allows for individual adjustment of the atomizing air, fan air and liquid flows and offers modular components to accommodate a wide range of spray applications. • VAA offers continuous operation and consists of a body, spray set-up and plug. • Mounting Kit 28945-001-316SS uses clamps to mount VAA nozzles. • VAAN features a manual shut-off needle that enables the flow of the liquid to be stopped. • Mounting Kit 28945-002-SS uses rods to mount VAA nozzles. Optimization Tips See Also http:// • Accessories – Air line filters • See page F2 for optimization tips. – Air pressure regulators – Liquid pressure regulators – Pressure gauges – Solenoid valves – Strainers Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F36 Nozzle Bodies/Nozzle Assemblies, VAU and VMAU Series VAA 1/4" NPT or BSPT with shut-off/clean-out needle VAANCO 1/8" NPT or BSPT 1/8" NPT or BSPT with shut-off needle 1/8" NPT or BSPT with clean-out needle VAU Clamp mounting kits Rod mounting kits 1/8" NPT or BSPT Materials Material Code Material 1/8" NPT or BSPT VAACO Mounting Kits 1/8" NPT or BSPT with shut-off/clean-out needle VAUPM VAAN Air Atomizing Nozzles VMAU Nozzles 303 Stainless Steel 303 Stainless Steel/Aluminum 316 Stainless Steel Air/Fluid Caps 303 Stainless Steel Nozzle Type VMAU VAA VAAN VAACO VAANCO VAU l l l l l l SS SSA VAUPM l l SS l l l l l l Other materials available upon request. Ordering Info Complete Nozzle Assembly Nozzle Body* Spray Set-up Only Spray Set-up 1/8 VAA – SS l l l Inlet Conn. Nozzle Body Assembly Type Material Code Spray Set-up + SUV128 – SS l l Spray Set-up No. Material Code *Includes retainer and gasket. BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: VF1650-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: VA67255-60-SS. To order spray nozzle without set-up, use inlet connection, nozzle body, and material code: 1/8VAA-SS. Order mounting kits separately: 28945-001-316SS. SUV128 l Spray Set-up No. – SS l Material Code To order spray set-up only, use spray set-up number and material code: SUV128-SS. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F37 Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, VMAU Series Performance Data VMAU Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination *At the stated pressure in psi. Liquid Capacity* Air Capacity* Capacity Press. Atomizing Air scfm Fan Air scfm Spray Coverage (in.) at Indicated Distance from Nozzle Fan Air Pressure Atom. Water Air Cap. Press. Press. Press. gph 10.0 10.0 .58 2.0 15.0 .73 2.6 20 Fluid Cap VMF1650 SUVM67B + Air Cap VMA67255-60 .84 3.1 30 1.1 3.9 40 1.3 4.6 50 1.6 5.8 60 1.8 6.6 70 2.0 7.5 80 2.3 8.3 90 2.5 9.0 1.0 .44 3.0 .74 5.0 1.0 10.0 1.4 20 30 15.0 1.7 20 1.9 40 60 10.0 10.0 Fluid Cap VMF2050 SUVM67A + Air Cap VMA67255-60 .58 2.0 15.0 .73 2.6 20 .84 3.1 30 1.1 3.9 40 1.3 4.6 50 1.6 5.8 60 1.8 6.6 70 2.0 7.5 80 2.3 8.3 90 2.5 9.0 1.0 3.0 5.0 .65 1.1 20 1.5 30 10.0 15.0 20 2.1 2.5 40 2.9 60 0 A B 5 C A B 10 C A B 20 C A B 30 C A B 40 C A B C 3.0 2.0 3.0 4.0 5.0 6.0 7.0 7.0 9.0 10.0 7.0 9.0 11.0 3.5 4.0 6.0 – – – 10.0 2.5 3.5 4.5 6.0 8.0 7.0 7.0 9.0 11.0 8.0 10.0 12.0 3.5 4.0 5.5 – – – 20 – – – – – – 6.0 9.0 8.0 8.0 12.0 13.0 10.0 12.0 14.0 3.5 5.5 7.0 3.0 2.0 3.0 4.5 4.0 5.0 6.0 6.0 7.0 8.0 7.0 9.0 11.0 5.0 6.5 7.0 7.0 8.0 10.0 10.0 2.0 3.0 4.0 5.0 7.0 7.0 7.0 9.0 10.0 8.0 10.0 12.0 4.5 5.0 6.0 7.0 8.0 10.0 20 2.0 3.0 4.0 6.0 7.0 8.0 8.0 10.0 12.0 9.0 12.0 14.0 6.0 7.5 9.0 7.0 8.0 10.0 3.0 2.0 3.0 4.5 3.0 4.0 5.0 5.0 6.0 7.0 6.0 8.0 10.0 5.5 6.0 7.0 7.0 9.0 11.0 10.0 2.0 3.0 4.5 4.0 4.5 6.0 6.0 7.5 10.0 7.0 9.0 11.0 5.5 6.5 8.0 7.0 9.0 12.0 20 2.0 3.0 4.0 4.5 6.0 7.0 7.0 9.0 12.0 8.0 10.0 12.0 6.0 7.0 9.0 8.0 9.0 11.0 3.0 2.5 3.5 6.0 3.5 4.5 5.0 5.0 6.0 8.0 6.0 8.0 10.0 5.0 6.5 8.0 7.0 9.0 11.0 10.0 2.0 3.0 5.0 4.0 5.0 5.0 5.0 7.0 9.0 7.0 9.0 11.0 6.0 7.5 9.0 7.0 9.0 11.0 20 2.0 3.0 4.5 4.0 5.5 6.0 6.0 8.0 10.0 8.0 9.0 11.0 6.0 7.5 10.0 8.0 10.0 12.0 3.0 2.5 3.5 6.0 3.0 4.5 4.0 4.0 5.0 6.0 5.0 7.0 9.0 5.0 6.5 10.0 7.0 9.0 11.0 10.0 2.5 3.0 5.0 3.5 4.0 4.5 4.5 5.0 7.0 7.0 9.0 11.0 6.0 7.5 11.0 8.0 10.0 12.0 20 2.0 3.0 4.5 3.5 5.0 5.0 5.0 7.0 9.0 7.0 9.0 11.0 6.0 7.5 11.5 8.0 10.0 12.0 3.0 2.0 3.0 4.0 5.0 6.0 8.0 7.0 9.0 10.0 7.0 9.0 11.0 3.5 4.0 4.5 – – – 10.0 2.5 3.5 4.5 6.0 8.0 9.5 7.0 9.0 11.0 8.0 10.0 12.0 4.5 5.0 6.0 – – – 20 – – – – 3.0 2.0 3.0 4.5 4.0 5.0 6.0 6.0 7.0 8.0 7.0 9.0 11.0 5.0 7.0 8.5 7.0 8.0 10.0 10.0 2.0 3.0 4.0 5.0 7.0 9.0 7.0 9.0 10.0 8.0 10.0 12.0 6.0 7.0 8.0 7.0 8.0 10.0 20 2.0 3.0 4.0 6.0 7.0 9.0 8.0 10.0 12.0 9.0 12.0 14.0 7.0 8.0 10.0 7.0 8.0 10.0 3.0 2.0 3.0 4.5 3.0 4.0 5.0 5.0 6.0 7.0 6.0 8.0 10.0 5.5 6.5 7.0 7.0 9.0 11.0 10.0 2.0 3.0 4.5 4.0 4.5 6.0 6.0 7.5 10.0 7.0 9.0 11.0 7.0 9.0 10.0 7.0 9.0 12.0 – – 6.0 9.0 11.0 8.0 12.0 13.0 10.0 12.0 14.0 7.0 8.5 9.5 20 2.0 3.0 4.0 4.5 6.0 8.0 7.0 9.0 12.0 8.0 10.0 12.0 8.0 10.0 12.0 8.0 9.0 11.0 3.0 2.5 3.5 6.0 3.5 4.5 7.0 5.0 6.0 8.0 6.0 8.0 10.0 6.0 8.0 9.0 7.0 9.0 11.0 10.0 2.0 3.0 5.0 4.0 5.0 7.5 5.0 7.0 9.0 7.0 9.0 11.0 6.0 8.0 9.5 7.0 9.0 11.0 20 2.0 3.0 4.5 4.0 5.5 8.0 6.0 8.0 10.0 8.0 9.0 11.0 6.0 8.5 10.5 8.0 10.0 12.0 3.0 2.5 3.5 6.0 3.0 4.5 6.0 4.0 5.0 6.0 5.0 7.0 9.0 6.5 7.5 9.0 7.0 9.0 11.0 10.0 2.5 3.0 5.0 3.5 4.0 6.5 4.5 5.0 7.0 7.0 9.0 11.0 6.5 9.0 11.0 8.0 10.0 12.0 20 2.0 3.0 4.5 3.5 5.0 7.0 5.0 7.0 9.0 7.0 9.0 11.0 6.5 9.0 12.0 8.0 10.0 12.0 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F38 Pressure Spray Set-ups, External Mix, VMAU Series Performance Data VMAU Spray Set-up Consists of Fluid and Air Cap Combination Liquid Capacity* Air Capacity* Capacity Press. Atomizing Fan Air Air scfm scfm Spray Coverage (in.) at Indicated Distance from Nozzle Fan Air Pressure Atom. Water Air Cap. Press. Press. Press. gph 10.0 SUVM67 Fluid Cap VMF2850 + Air Cap VMA67255-60 10.0 15.0 20 30 40 50 60 70 80 90 .58 .73 .84 1.1 1.3 1.6 1.8 2.0 2.3 2.5 2.0 2.6 3.1 3.9 4.6 5.8 6.6 7.5 8.3 9.0 1.0 1.26 3.0 2.2 5.0 2.8 10.0 4.0 15.0 4.9 20 5.6 20 30 40 60 10.0 Fluid Cap VMF3578 SUVM113A + Air Cap VMA113289-60 10.0 15.0 20 30 40 50 60 70 80 90 1.6 2.0 2.4 3.3 3.6 4.5 5.2 5.9 6.5 7.2 3.9 4.8 5.8 7.6 9.3 11.0 12.7 14.4 15.9 17.6 1.0 2.1 3.0 3.6 5.0 4.7 10.0 6.6 15.0 8.0 20 9.4 20 30 40 60 10.0 SUVM113 Fluid Cap VMF4078 + Air Cap VMA113289-60 10.0 15.0 20 30 40 50 60 70 80 90 1.6 2.0 2.4 3.3 3.6 4.5 5.2 5.9 6.5 7.2 3.9 4.8 5.8 7.6 9.3 11.0 12.7 14.4 15.9 17.6 1.0 2.9 3.0 4.9 5.0 6.4 10.0 9.0 15.0 11.0 20 12.8 20 30 40 60 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 3.0 6.0 10.0 0 5 10 20 30 40 A B C A B C A B C A B C A B C A B C 2.0 – – 2.5 – – 2.5 – – 2.5 2.0 – 2.5 2.5 2.0 – – – 1.5 – – 2.0 – – 2.0 2.5 2.0 2.0 2.5 2.5 2.0 – – 2.0 2.0 – 2.0 1.5 – 1.5 1.5 2.0 2.0 2.0 2.0 3.0 – – 3.0 – – 3.0 – – 3.5 3.0 – 3.5 3.5 3.0 – – – 2.0 – – 2.5 – – 2.5 3.5 3.0 2.5 3.0 3.0 2.5 – – 3.0 4.0 – 2.5 2.5 – 2.5 2.5 3.0 3.0 3.0 3.0 5.0 – – 4.5 – – 4.5 – – 5.0 4.5 – 5.5 5.5 4.5 – – – 3.0 – – 3.5 – – 4.0 5.56 4.0 3.0 4.5 5.0 4.0 – – 5.0 5.0 – 4.0 3.0 – 4.5 4.0 8.0 4.0 4.0 4.0 7.0 8.5 – 6.0 6.0 7.0 5.0 5.0 – 4.0 4.5 4.5 4.0 4.5 4.0 8.0 10.0 12.0 5.0 7.0 7.0 4.0 5.0 4.5 4.0 4.0 4.5 2.0 4.0 4.0 7.0 8.0 9.0 6.5 7.0 6.5 5.0 5.0 5.5 4.0 4.5 4.5 3.5 5.0 3.5 9.0 11.0 – 7.0 8.0 9.0 6.0 7.0 – 5.0 5.5 6.0 4.5 5.0 5.5 10.5 12.0 14.0 7.0 9.0 9.0 5.0 7.0 6.0 5.0 5.0 6.0 4.0 4.5 4.5 7.5 11.5 13.0 9.0 9.0 10.5 7.0 7.5 8.0 6.0 6.0 6.5 5.0 7.5 5.0 14.0 15.0 – 9.0 11.0 12.0 8.0 10.0 – 7.5 8.0 9.0 7.0 7.5 8.0 14.0 16.0 16.5 10.0 12.0 12.0 7.0 10.0 8.0 6.0 7.5 8.5 5.0 6.0 7.5 17.0 17.0 18.0 11.0 12.0 14.0 11.0 10.0 11.0 8.0 8.0 7.5 7.0 6.0 8.0 9.0 12.0 10.0 7.5 9.0 10.0 6.0 8.0 8.0 5.0 7.0 7.0 5.0 6.0 6.0 10.0 12.0 12.0 8.0 9.0 10.5 6.0 6.5 6.5 5.5 6.0 6.5 5.0 5.5 5.5 11.0 12.0 12.0 9.0 9.5 11.0 7.0 8.0 8.0 6.5 7.0 7.0 6.0 8.0 6.0 12.0 15.0 12.0 9.0 11.0 12.0 8.0 11.0 11.0 7.0 8.0 9.0 6.0 7.0 8.0 13.0 14.0 16.5 11.0 12.0 13.5 8.0 10.0 10.0 7.5 8.0 9.0 6.5 7.0 7.5 15.0 17.0 17.0 13.0 12.0 14.0 11.0 10.0 10.5 8.5 9.0 10.0 7.5 10.5 8.0 15.0 21 16.0 11.0 15.0 17.0 9.0 15.0 14.0 10.0 11.0 13.5 8.0 9.5 10.0 17.0 18.0 22 14.0 15.0 16.5 11.0 13.0 13.0 11.0 10.0 12.0 8.0 9.5 9.5 18.0 22 23 18.0 17.0 18.5 13.5 14.5 14.0 12.0 12.5 14.5 10.0 12.0 13.0 9.0 15.0 14.0 8.0 12.0 13.0 8.0 11.0 11.0 8.0 9.0 10.0 7.0 8.0 8.0 8.0 – – 8.5 – – 8.0 9.0 10.0 8.0 9.0 10.0 8.0 8.0 8.5 10.0 – – 10.0 14.0 16.0 9.0 11.0 11.5 9.0 10.0 10.0 8.0 9.0 8.5 10.0 18.0 18.0 10.0 15.0 17.0 10.0 14.0 14.0 9.0 12.0 12.0 9.0 11.0 11.0 10.0 – – 12.0 – – 11.0 12.0 14.0 10.5 11.5 14.0 10.0 10.0 11.0 13.5 – – 13.0 15.0 19.0 12.0 13.5 15.0 12.0 13.0 14.0 11.0 12.5 10.5 12.0 19.0 23 13.0 19.0 20 13.0 19.0 19.0 11.0 16.0 16.0 11.0 13.0 14.0 13.0 – – 14.0 – – 14.0 15.5 16.0 14.0 16.0 18.5 12.0 13.0 10.0 15.0 – – 16.5 18.5 20 17.0 16.0 20.5 16.0 17.0 19.0 14.0 15.5 16.5 – – 15.0 5.5 11.0 14.0 5.0 9.0 12.0 5.5 9.0 10.0 5.5 6.5 9.0 – – – 7.0 – – 8.0 9.0 – 8.0 8.0 10.0 7.5 10.0 10.0 – – – – – – 8.0 10.0 12.0 8.5 10.5 11.0 9.0 9.0 9.5 – – 19.0 6.5 12.0 17.0 5.5 11.0 16.0 6.5 10.0 12.5 6.5 9.0 11.0 – – – 8.5 – – 10.5 11.0 – 10.0 11.0 13.5 9.5 12.0 12.5 – – – – – – 11.0 12.0 15.0 11.5 12.0 13.0 11.0 12.5 13.0 – – 23 8.0 14.0 20 6.5 12.0 19.0 8.0 11.5 16.0 7.5 11.0 15.0 – – – 11.0 – – 13.0 12.0 – 13.0 14.0 18.0 14.0 15.0 18.0 – – – – – – 13.0 15.5 18.0 15.0 16.0 17.0 15.0 18.0 16.0 – – – 8.0 11.0 17.0 7.0 9.0 16.0 7.0 11.0 13.0 7.0 8.0 10.0 – – – 5.5 – – 7.5 – – 7.5 8.0 8.5 7.5 9.0 9.0 – – – – – – – 7.5 9.5 8.5 8.5 10.0 8.0 9.5 9.5 – – – 9.0 12.0 20 8.0 10.0 20 9.0 13.0 18.0 9.0 10.0 14.0 – – – 7.0 – – 9.0 – – 8.5 8.5 10.5 9.5 12.0 12.0 – – – – – – – 10.0 12.0 11.0 11.0 12.0 10.5 11.5 12.5 – – – 12.0 12.0 23 10.0 12.0 22 11.0 15.0 21 11.0 12.0 16.0 – – – 9.0 – – 11.0 – – 12.0 12.0 14.5 12.0 15.0 15.0 – – – – – – – 14.0 17.0 14.5 15.0 19.0 14.0 16.5 16.5 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F39 Air Atomizing Nozzles Spray Set-up No. *At the stated pressure in psi. Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, VMAU Series Performance Data VMAU Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination *At the stated pressure in psi. Liquid Capacity* Air Capacity* Spray Coverage (in.) at Indicated Distance from Nozzle Fan Air Pressure Atom. Water Air Press. Cap. Press. Press. Atomizing Fan Press. gph Air Air scfm scfm Capacity 10.0 Fluid Cap VMF60100 SUVM128 + Air Cap VMA1282100-60 10.0 15.0 20 30 40 50 60 70 80 90 1.8 2.2 2.6 3.4 4.3 5.0 5.8 6.6 7.4 8.0 4.9 5.9 7.0 9.1 11.2 13.3 15.3 17.2 19.2 21 1.0 6.6 3.0 10.8 5.0 13.8 10.0 19.8 15.0 24 20 28.2 20 30 40 60 10.0 Fluid Cap VMF80125 SUVM152 + Air Cap VMA1522110-60 10.0 15.0 20 30 40 50 60 70 80 90 2.1 2.6 3.2 4.1 5.0 5.9 6.9 7.0 7.7 8.7 5.1 6.2 7.3 9.5 11.7 13.9 16.0 18.0 20.1 22 1.0 12.6 3.0 19.2 5.0 24.6 10.0 36 15.0 43.2 20 49.8 20 30 40 60 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 1.0 3.0 6.0 0 5 10 15 20 25 A B C A B C A B C A B C A B C A B C – – – – – – 1.5 2.0 1.0 2.0 2.5 2.0 3.0 3.0 2.5 – – – – – – 2.5 – – 2.0 – – 1.5 2.0 – – – – – – – 3.0 3.0 3.0 3.0 3.0 3.0 4.0 4.0 3.5 – – – – – – 3.0 – – 3.0 – – 2.0 3.0 – – – – – – – 4.5 5.0 5.0 5.5 5.5 4.0 6.0 6.0 4.0 – – – – – – 4.0 – – 3.0 – – 3.0 3.5 – 10.0 9.5 10.0 6.0 7.0 7.5 5.0 5.5 4.5 5.0 5.0 5.0 4.5 4.5 4.0 10.5 – – 6.0 7.0 – 6.0 5.0 – 4.0 5.0 – 3.0 5.0 – 13.5 12.5 13.0 8.5 10.0 10.5 7.0 8.0 6.0 6.0 7.0 7.0 6.0 6.5 5.5 13.0 – – 8.0 9.5 – 8.0 7.0 – 5.0 7.5 – 5.0 5.0 – 21 19.0 20 13.0 14.5 14.5 9.5 13.5 9.5 9.0 10.0 10.0 9.0 9.5 7.5 21 – – 13.0 15.0 – 12.0 10.5 – 6.0 10.0 10.0 6.5 7.5 – 13.0 14.0 14.0 8.0 9.0 10.0 7.0 8.0 8.0 6.0 6.5 6.0 5.5 6.0 5.0 13.0 13.0 14.0 9.5 10.0 10.0 7.5 8.0 8.5 6.0 7.0 7.0 6.5 6.0 6.0 16.0 18.0 19.0 11.0 12.5 14.0 10.0 11.0 11.0 9.0 9.5 10.0 8.0 8.5 7.0 17.0 17.5 19.0 13.0 14.0 13.5 11.0 12.0 11.0 8.0 10.0 10.0 7.5 8.5 7.0 22 24 26 17.5 18.0 19.5 14.0 15.0 16.0 13.0 14.0 15.0 12.0 12.0 11.0 26 26 26.5 18.5 20 21 17.0 19.0 16.0 12.0 15.0 14.0 10.5 12.0 12.0 12.0 12.5 16.0 9.5 10.0 12.0 9.0 9.5 9.5 8.0 8.0 9.0 6.5 7.0 6.5 13.0 12.0 16.5 10.0 11.0 12.0 10.0 10.5 11.0 8.0 8.5 8.5 8.0 7.0 7.0 16.0 17.0 22 13.0 14.0 17.5 11.0 13.0 13.0 11.0 12.0 13.0 10.0 10.0 9.0 19.0 21 21 15.0 15.5 17.5 13.5 13.5 14.0 12.0 12.5 12.0 10.0 10.0 10.0 21 24 30 17.5 20 24 14.0 19.0 19.0 15.5 18.0 18.0 14.0 14.0 13.5 27 29 28 22 20.5 26 19.5 20 20 16.5 18.0 17.0 14.0 14.5 14.0 – 12.0 18.0 8.0 9.5 11.0 10.0 10.0 10.0 8.5 10.0 10.0 8.5 9.0 8.0 13.0 13.0 16.0 8.0 9.5 11.0 10.0 10.0 10.0 8.5 10.0 10.0 8.5 9.0 8.0 – 16.0 24.5 12.0 13.0 17.5 14.0 14.0 14.5 11.5 13.0 14.0 9.0 11.0 11.0 18.0 19.5 24 12.0 13.0 17.5 14.0 14.0 14.5 11.5 13.0 14.0 9.0 11.0 11.0 – 20 34 14.0 18.5 26 17.0 19.0 21.5 14.5 19.0 20 14.5 16.0 17.0 24 30 34 14.0 18.5 26 17.0 19.0 21.5 14.5 19.0 20 14.5 16.0 17.0 – – 19.0 8.0 10.0 12.0 9.5 10.0 12.0 9.0 10.0 11.0 8.5 9.0 9.0 10.0 15.0 – 9.0 12.5 15.0 9.0 12.0 12.0 9.0 10.0 11.0 8.0 10.0 10.0 – – 24 10.5 13.0 18.0 12.0 13.0 16.0 13.0 13.5 14.5 12.0 12.0 12.0 15.0 23 – 14.0 13.0 21 14.0 16.5 16.0 13.0 15.0 16.0 12.0 13.0 14.0 – – 33 12.0 16.0 27 16.0 16.5 22 17.0 19.0 22 16.0 16.5 18.0 21.5 30 – 21 25 32 19.5 22.5 24 18.0 21 23 18.0 18.5 19.0 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F40 Pressure Spray Set-ups, External Mix, VAU Series Features and Benefits Air Caps • The dimensions “A”, “B” and “C” of the flat spray pattern are controlled by the combination of fan air pressure and atomizing air pressure. Fan air Atomized liquid • The liquid flow rate is constant and not affected by the air pressure. Fan air C External mix with fan air: flat spray pattern Without fan air: round spray pattern. B Flat spray pattern 28207-101-SS cap ring and 29154-001-BUC must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. A 6" (15 cm) 9" (23 cm) 15" (38 cm) D Performance Data VAU SUV67B SUV67A SUV67 Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap VF1650 + Air Cap VA67255-60 Fluid Cap VF2050 + Air Cap VA67255-60 Fluid Cap VF2850 + Air Cap VA67255-60 Air Capacity*† Press. Atomizing Air scfm Spray Coverage (inches) at Indicated Distance from Nozzle Liquid Capacity*† Fan Air scfm Press. Cap. gph Atom. Air Press. 10.0 15.0 20 30 40 50 60 70 80 90 .44 .53 .62 .82 1.0 1.3 1.5 1.7 2.0 2.2 2.2 2.7 3.3 4.4 5.5 6.6 7.6 8.6 9.6 10.6 3.0 3.0 5.0 5.0 10.0 10.0 15.0 15.0 20 20 .7 .7 1.0 1.0 1.4 1.4 1.7 1.7 1.9 1.9 10.0 10.0 15.0 20 30 40 50 60 70 80 90 .44 .53 .62 .82 1.0 1.3 1.5 1.7 2.0 2.2 2.2 2.7 3.3 4.4 5.5 6.6 7.6 8.6 9.6 10.6 3.0 3.0 5.0 5.0 10.0 10.0 15.0 15.0 20 20 1.1 1.1 1.5 1.5 2.1 2.1 2.5 2.5 2.9 2.9 10.0 10.0 15.0 20 30 40 50 60 70 80 90 .44 .53 .62 .82 1.0 1.3 1.5 1.7 2.0 2.2 2.2 2.7 3.3 4.4 5.5 6.6 7.6 8.6 9.6 10.6 3.0 3.0 5.0 5.0 10.0 10.0 15.0 15.0 20 20 2.2 2.2 2.8 2.8 4.0 4.0 4.9 4.9 5.6 5.6 10.0 Fan Air Pressure Water Press. 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 30 40 60 30 40 60 30 40 60 0†† A 2.0 2.5 2.0 2.0 2.0 2.0 2.5 2.0 2.0 2.5 2.5 2.0 2.0 2.5 2.0 2.0 2.0 2.0 2.5 2.0 2.0 2.5 2.5 2.0 2.0 2.0 – 2.5 2.0 2.0 2.5 2.0 2.0 2.5 2.5 2.0 B 3.0 3.5 3.0 3.0 2.5 3.0 3.5 3.0 3.0 3.5 3.0 3.0 3.0 3.5 3.0 3.0 3.0 3.0 3.5 3.0 3.0 3.5 3.5 3.0 3.0 2.5 – 3.0 3.0 2.5 3.5 3.0 3.0 3.5 3.5 3.0 10 C 4.0 4.5 4.0 4.5 4.5 4.0 6.0 5.0 4.5 6.0 5.0 4.5 4.0 4.5 4.0 4.5 5.0 4.0 5.5 5.0 4.5 6.0 5.5 4.5 5.0 4.0 – 4.5 5.0 4.0 5.0 5.0 5.0 5.5 5.5 4.5 A 7.0 7.5 8.0 5.0 6.0 7.0 5.0 6.0 6.0 4.0 4.5 5.0 8.0 8.0 8.0 5.5 7.0 7.0 5.0 6.5 6.5 4.5 5.0 5.5 9.0 12.0 10.0 6.0 8.0 8.0 5.0 7.0 7.0 5.0 6.0 6.0 B 9.0 10.0 12.0 6.0 7.5 9.0 6.0 7.0 8.0 5.0 5.0 7.0 10.0 12.0 12.0 7.0 9.0 10.0 6.5 7.5 8.5 5.5 6.0 7.5 12.0 15.0 12.0 8.0 11.0 11.0 7.0 8.0 9.0 6.0 7.0 8.0 40 C 10.0 12.0 14.0 7.0 10.0 13.0 8.0 10.0 12.0 6.0 7.0 9.0 12.0 15.0 15.0 8.0 12.0 13.0 9.0 6.5 12.5 7.0 8.5 9.5 15.0 21 16.0 9.0 15.0 14.0 10.0 11.0 13.5 8.0 9.5 10.0 A 6.0 7.0 9.0 8.0 8.0 10.0 8.0 9.0 10.0 8.0 8.0 9.0 6.5 9.0 – 8.0 10.0 13.0 8.0 9.5 11.5 8.0 9.0 10.0 7.0 12.0 – 8.0 11.0 16.0 8.0 11.0 13.0 8.0 10.0 12.0 B 8.0 8.0 11.0 10.0 10.0 12.0 10.0 11.0 12.0 11.0 10.0 12.0 8.5 14.0 – 10.0 12.0 16.0 10.0 11.5 15.0 10.5 11.0 14.0 9.0 20 – 10.0 13.0 20 10.0 13.0 18.0 10.0 13.0 17.0 60 C 11.0 11.0 14.0 14.0 13.0 15.0 14.0 14.0 14.0 13.0 13.0 16.0 11.0 18.0 – 14.0 14.0 18.0 14.0 14.0 17.0 13.0 14.0 18.0 11.0 23 – 13.0 13.0 22 13.0 15.0 21 13.0 16.0 21 A 6.0 7.0 8.0 8.0 8.0 9.5 9.0 9.0 10.0 9.0 9.0 10.0 6.0 7.0 8.0 8.0 9.0 9.5 9.0 9.0 11.0 9.0 10.0 11.0 7.0 – – 8.0 10.0 – 8.0 10.0 12.0 8.0 11.0 13.0 B 8.0 8.0 10.0 11.0 10.0 11.5 11.0 11.0 12.0 11.0 12.0 13.0 9.0 10.0 10.0 11.0 10.0 11.5 11.0 12.0 14.0 11.0 12.0 14.0 9.0 – – 10.0 11.0 – 11.0 12.0 17.0 10.0 13.0 18.0 C 11.0 12.0 13.0 14.0 12.0 14.5 14.0 13.0 15.0 14.0 14.0 17.0 12.0 13.0 13.0 14.0 13.0 14.5 14.0 15.0 18.0 14.0 14.0 18.0 12.0 – – 13.0 13.0 – 13.0 13.0 21 13.0 15.0 21 †Since the pressures of the air and liquid lines are independently controlled, any combination of these air and liquid pressures can be used. The total air capacity is the sum of the atomizing air scfm and the fan air. For instance, for atomizing air at 10 psi and fan air at 30 psi, the total is equal to .44 scfm + 4.4 scfm for a total of 4.84 scfm. ††At 0 psi fan air pressure the spray forms a round spray pattern. Request Data Sheets 37459M-V67B, 37459M-V67A and 37459M-V67. Spray set-ups are interchangeable, but each set-up uses a different needle size. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F41 Air Atomizing Nozzles Spray Set-up No. *At the stated pressure in psi. Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, VAU Series Performance Data VAU Spray Set-up No. SUV113A SUV113 SUV128 SUV152 *At the stated pressure in psi. Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap VF3578 + Air Cap VA113293-60 Fluid Cap VF4078 + Air Cap VA113293-60 Fluid Cap VF60100 + Air Cap VA1282125-60 Fluid Cap VF80125 + Air Cap VA1522125-60 Air Capacity*† Press. Spray Coverage (inches) at Indicated Distance from Nozzle Liquid Capacity*† Atomizing Fan Air Air scfm scfm Press. Cap. gph Atom. Air Press. 10.0 15.0 20 30 40 50 60 70 80 90 1.6 2.0 2.4 3.2 4.0 4.7 5.5 6.3 7.0 7.8 3.5 4.4 5.4 7.2 8.9 10.6 12.3 14.0 15.5 17.2 3.0 3.0 5.0 5.0 10.0 10.0 15.0 15.0 20 20 3.6 3.6 4.7 4.7 6.6 6.6 8.0 8.0 9.4 9.4 10.0 10.0 15.0 20 30 40 50 60 70 80 90 1.6 2.0 2.4 3.2 4.0 4.7 5.5 6.3 7.0 7.8 3.5 4.4 5.4 7.2 8.9 10.6 12.3 14.0 15.5 17.2 3.0 3.0 5.0 5.0 10.0 10.0 15.0 15.0 20 20 4.9 4.9 6.4 6.4 9.0 9.0 11.0 11.0 12.8 12.8 10.0 10.0 15.0 20 30 40 50 60 70 80 90 1.6 2.0 2.4 3.1 3.9 4.7 5.4 6.2 7.0 7.8 3.9 4.9 6.0 8.1 10.2 12.3 14.3 16.3 18.2 20 3.0 3.0 5.0 5.0 10.0 10.0 15.0 15.0 20 20 10.0 10.0 13.0 13.0 18.4 18.4 23 23 26 26 10.0 10.0 15.0 20 30 40 50 60 70 80 90 1.8 2.2 2.6 3.6 4.4 5.3 6.2 7.0 7.8 8.6 3.9 4.8 5.8 7.8 9.8 11.7 13.6 15.4 17.2 18.8 3.0 3.0 5.0 5.0 10.0 10.0 15.0 15.0 20 20 18.3 18.3 24 24 33 33 41 41 47 47 10.0 Fan Air Pressure Water Press. 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 3.0 10.0 20 30 40 60 30 40 60 30 40 60 30 40 60 0†† A 2.5 2.0 – 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.0 – – 2.5 2.5 2.0 2.5 2.5 2.5 2.5 2.5 2.5 3.0 – – 3.0 2.5 – 3.0 2.5 2.5 3.0 3.0 3.0 3.0 – – 3.0 – – 3.0 3.0 – 3.0 3.0 2.5 B 3.5 3.0 – 3.0 3.5 3.5 3.0 3.5 3.5 3.5 3.5 3.5 4.0 – – 3.5 3.5 3.0 3.5 3.5 3.5 3.5 3.5 3.5 4.0 – – 4.0 3.5 – 4.0 3.5 3.5 4.0 4.0 3.5 4.0 – – 4.0 – – 4.0 3.5 – 4.0 4.0 3.0 10 C 5.0 4.5 – 5.0 5.0 5.5 5.0 5.0 5.0 5.0 4.5 4.5 6.0 – – 6.0 5.0 5.0 6.0 5.5 5.5 6.0 5.5 5.5 5.0 – – 5.0 5.0 – 5.5 5.0 5.0 6.0 5.0 5.0 5.0 – – 5.0 – – 5.5 5.0 – 6.0 6.5 5.0 A 9.0 10.0 9.0 4.0 5.0 4.0 3.5 4.0 4.0 3.0 3.0 3.0 9.0 8.0 9.0 4.0 4.5 4.5 3.5 4.0 3.5 2.5 3.0 3.0 7.0 – – 4.0 4.0 – 3.5 4.0 3.0 3.0 3.5 3.0 8.0 – – 5.0 5.0 – 5.0 4.5 – 4.0 4.0 3.5 B 13.0 14.0 13.0 5.0 7.0 6.0 4.5 5.0 5.5 4.0 4.0 4.5 12.0 11.0 12.0 6.0 6.0 6.0 5.0 6.0 5.0 4.0 4.0 4.0 10.0 – – 6.0 6.0 – 5.0 5.0 5.0 4.0 4.5 4.0 11.0 – – 6.5 7.0 – 6.0 5.5 – 6.0 6.5 4.5 40 C 17.0 16.0 17.0 7.0 9.0 9.0 6.5 6.5 8.0 6.0 6.0 7.0 18.0 15.0 15.0 8.0 8.0 9.0 7.0 8.0 8.0 7.0 6.0 6.0 13.0 – – 8.0 8.5 – 7.0 7.0 8.0 6.0 7.0 5.5 15.0 – – 9.0 9.0 – 9.0 7.5 – 8.0 7.5 6.0 A – – 18.0 11.0 13.0 13.0 9.0 10.0 11.0 8.0 8.0 10.0 – 24 21 12.0 14.0 14.0 10.0 12.0 13.0 9.0 10.0 9.0 – 21 17.0 12.0 12.0 11.0 10.0 11.0 9.0 8.0 9.0 8.0 – 21 18.0 13.0 13.0 13.0 11.0 11.0 10.0 9.0 10.0 7.0 B – – 24 14.0 16.0 19.0 12.0 14.0 15.0 10.0 11.0 12.0 – 29 28 15.0 18.0 18.0 13.0 16.0 17.0 11.0 13.0 13.0 – 26 22 14.0 16.0 15.0 12.0 14.0 13.0 10.0 12.0 10.0 – 27 22 18.0 17.0 17.0 15.0 15.0 14.0 12.0 13.0 12.0 60 C – – 29 18.0 22 24 14.0 18.0 21 13.0 14.0 16.0 – 35 – 19.0 23 27 17.0 20.0 22 14.0 16.0 17.0 – 33 30 21 22 21 17.0 20 17.0 13.0 16.0 15.0 – 35 30 23 22 22 19.0 20 20 16.0 17.0 15.0 A – – – 12.0 18.0 17.0 11.0 15.0 15.0 10.0 11.0 12.0 – – – 12.0 17.0 18.0 12.0 15.0 16.0 10.0 13.0 12.0 – – 22 17.0 15.0 15.0 12.0 14.0 13.0 10.0 12.0 12.0 – – – – 18.0 17.0 17.0 16.0 14.0 14.0 13.0 12.0 B – – – 15.0 21 22 13.0 18.0 20 12.0 15.0 17.0 – – – 15.0 22 23 14.0 18.0 20 12.0 16.0 17.0 – – 27 19.0 21 18.0 17.0 18.0 18.0 13.0 16.0 16.0 – – – – 25 22 24 20 19.0 17.0 17.0 16.0 C – – – 18.0 26 26 18.0 22 25 17.0 18.0 22 – – – 19.0 25 27 18.0 22 24 17.0 20 23 – – 34 25 28 24 21 25 24 18.0 21 21 – – – – 27 29 30 29 27 21 23 21 †Since the pressures of the air and liquid lines are independently controlled, any combination of these air and liquid pressures can be used. The total air capacity is the sum of the atomizing air scfm and the fan air. For instance, for atomizing air at 10 psi and fan air at 30 psi, the total is equal to .44 scfm + 4.4 scfm for a total of 4.84 scfm. ††At 0 psi fan air pressure the spray forms a round spray pattern. Request Data Sheets 37459M-V113A, 37459M-V113, 37459M-V128 and 37459M-V152. Spray set-ups are interchangeable, but each set-up uses a different needle size. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F42 Nozzle Bodies/Nozzle Assemblies, 1/2J Series 1/2J 1/2J Series air atomizing nozzles Plug CP1706 1/2J Spray set-up 1/2" NPT or BSPT Shut-off needle assembly 12810 1/2JN 1 2 3 4 5 1. Retainer ring CP1705 2. Air cap 3. Fluid cap 4. Fluid cap gasket CP8491 5. Nozzle body CP1701 1/2JN 1/2JCO 1/2JCO Features and Benefits • 1/2J air atomizing series ranges in capacity from 4.1 to 306 gph (15.5 to 1158 l/h). • The nozzles are available with shut-off and clean-out needles. • 1/2J body has liquid and air feeds at opposite ends of the body and is provided with a removable plug so other needle assemblies may be added in the future. • 1/2JN features a manual shut-off needle that enables the flow of liquid to be stopped. 1/2" NPT or BSPT with clean-out needle • 1/2JCO features a clean-out needle that is activated manually. – The needle slides through the liquid orifice to clear obstructions. – Ideal for intermittent spraying applications when liquid can dry in the orifice between uses. Optimization Tips • See page F2 for optimization tips. See Also http:// • Accessories – Air line filters – Air pressure regulators Materials Material Material Code – Pressure gauges – Strainers Complete Nozzle Assembly Nozzle Type J JN Nozzle Body* JCO Nickel-plated Brass (none) l l l 303 Stainless Steel SS l l l SSBR l l l SS l l l Spray Set-ups 303 Stainless Steel – Solenoid valves Ordering Info Nozzle Bodies Nickel-plated Brass Air Cap and 303 Stainless Steel Fluid Cap – Liquid pressure regulators 1/2 JN Inlet Conn. Nozzle Body Assembly Type l l Spray Set-up Only Spray Set-up – SS + SU77 – l l Material Code Spray Set-up No. SS l Material Code *Includes retainer and gasket. BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 250375-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: 422-6-73-70°. Spray Set-up SU77 – l Spray Set-up No. SS l Material Code To order spray set-up only, use spray set-up and material code: SU77-SS. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F43 Air Atomizing Nozzles 1/2" NPT or BSPT with shut-off needle Clean-out needle assembly 11829 Air Atomizing Nozzles Nozzle Bodies/Nozzle Assemblies, 1/2J Series Features and Benefits Optimization Tips • JBC features the center lines of the air and liquid inlet entering in the back of the nozzle and parallel to the spray projection axis. • See page F2 for optimization tips. • 1/2JBCJ features a steam jacket around the nozzle body for spraying liquids that are too viscous to spray at room temperature. See Also • 2J is a dual spray assembly with opposing spray set-ups perpendicular to opposing air and liquid inlets. • Accessories – Air line filters • Thick wall adapters replace retainer rings on nozzle assemblies and fit into threaded wall openings holding the nozzle securely in place. – Air pressure regulators http:// – Pressure gauges – Solenoid valves – Liquid pressure regulators – Strainers • For JBC, request Data Sheets 4921, 6885 and 6185 • For 1/2JBCJ, request Data Sheets 4610 and 6331 • For 2J, request Data Sheets 5356 and 6530 • For thick wall adapters, request Data Sheets 3378, 7003 and 7323 Back Connect 1/2" NPT or BSPT (F) inlet connection Steam Jacket Twin Spray 3/8" NPT or BSPT (F) steam inlet/outlet connection 1/2" NPT or BSPT (F) air and liquid inlet connection 1/2" NPT or BSPT (F) inlet connection Thick Walls Please refer to data sheets 1/2JBC air atomizing nozzle 1/2JBC air atomizing nozzle used to spray seasoned cooking oil onto corn snacks. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F44 Pressure Spray Set-ups, Internal Mix, 1/2J Series Features and Benefits Air Caps • For wide angle round, round, 360° circular and flat sprays, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Wide angle round, round, flat and 360° circular spray air caps produce wide angle round hollow cone spray, round hollow cone spray, flat spray and 360° circular spray patterns. Fluid cap C B A Air cap 9" (23 cm) 18" (46 cm) 27" (69 cm) D 8491 gasket 1705 retainer ring Air Atomizing Nozzles 8491 gasket must be ordered separately from the spray set-up, but is included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Flat Spray *At the stated pressure in psi. Spray Set-up Spray Consists of Spray Set-up Fluid and Pattern No. Air Cap Combination SU75 SU85 Fluid Cap 250375 + Air Cap 4533102 Fluid Cap 251376 + Air Cap 4693102 Flat Flat Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 5 15 25 35 55 Air Air Air Air Air A B C D gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) (in.) (in.) (ft.) – – – 28 39 22.4 44 44.1 31.5 58 53 40 – – – – – – 30 31.8 24 46 37.2 33.5 60 45.6 42 – – – – – – 32 24.6 25.9 48 31.2 35.1 63 38 44 – – – – – – 34 19.8 27.5 50 27 36.9 65 31 47 – – – 23 10.0 35.4 11.1 18.0 103 15.4 26 155 17.7 36 180 54 222 29.1 12.0 26.4 13.4 20 81.6 17.6 28 135 38 162 25.4 56 198 31.2 20 – – – 22 63.6 19.8 30 115 22.5 40 147 27.8 58 186 34 – – – 24 49.3 22.6 32 100 25.1 42 131 30.2 60 180 36.3 – – – – – – 34 84 27.5 44 116 32.6 62 166 38.9 – – – – – – 36 69.5 30 46 101 35.1 64 154 41.6 – – – – – – 38 56.4 32.6 48 81.5 37.6 66 142 44.1 – – – – – – 40 45.7 35.3 50 75.6 40.2 68 130 46.6 – – – – – – – – – 52 62.4 42.7 70 119 49.3 – – – – – – – – – – – – 72 108 51.6 – – – – – – – – – – – – 74 97.4 54.2 – – – – – – – – – – – – 76 87.5 57.1 20 10 17 28 35 18 30 15 18 29 36 19 10 5 20 34 47 13 20 15 34 62 83 15 32 25 34 62 82 17 44 35 36 66 85 19 64 55 36 67 89 21 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F45 Air Atomizing Nozzles Pressure Spray Set-ups, Internal Mix, 1/2J Series Performance Data Wide Angle Round and Round Spray Spray Set-up Spray Consists of Spray Set-up Fluid and Pattern No. Air Cap Combination SU77 SU78 SU79 SU89 SU72 SU82 Fluid Cap 250375 Wide + Angle Air Cap Round 422-6-73-70° Fluid Cap 250375 Wide + Angle Air Cap Round 422-6-94-70° Fluid Cap 250375 + Air Cap 469-6-12570° Fluid Cap 251376 + Air Cap 469-6-13070° Fluid Cap 250375 + Air Cap 4221250 Fluid Cap 251376 + Air Cap 4691312 Wide Angle Round Wide Angle Round Round Round *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 5 15 25 35 55 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. – – – – – – 28 – – – – – – 30 33 A (in.) B (in.) C (in.) D (ft.) 8.4 40 28.8 11.3 58 66 12.2 30 25 13-1/2 19 26-1/2 22 19.8 10.8 42 15.6 13.9 60 42 15.0 40 35 13-1/2 19 26-1/2 24 14 19-1/2 – – – – – – – – – – – – 62 25.2 18.2 60 55 8.0 10.0 12.0 – – 10.0 12.0 14.0 – – 10.0 12.0 – – – – – – – – – – 18.0 20 22 24 – – 10.0 12.0 – – – – – – – – – – 27 15.0 8.4 – – 34.2 21.6 12.0 – – 35.4 26.4 – – – – – – – – – – 9.0 6.7 5.4 4.1 – – 35.4 26.4 – – – – – – – – – – 6.5 8.2 9.8 – – 11.4 13.0 14.7 – – 11.1 13.4 – – – – – – – – – – 12.4 13.7 14.7 15.7 – – 11.1 13.4 – – – – – – – – – – 18.0 20 22 24 – 26 28 30 32 34 18.0 20 22 24 – – – – – – – – 28 32 36 38 40 42 18.0 20 22 24 – – – – – – – – 42 29.4 20.2 14.4 – 46.2 37.2 28.4 21.6 16.2 103 81.6 63.6 49.3 – – – – – – – – 31.7 22.5 15.9 13.2 11.1 9.2 103 81.6 63.6 49.3 – – – – – – – – 7.0 8.8 10.5 12.2 – 20.2 22 23.7 25.3 27 15.4 17.6 19.8 22.6 – – – – – – – – 14.9 17.0 19.3 20.4 21.5 22.6 15.4 17.6 19.8 22.6 – – – – – – – – 32 34 36 38 40 40 42 44 46 48 26 28 30 32 34 36 38 40 – – – – 38 44 50 54 58 60 26 28 30 32 34 36 38 40 – – – – 47 36 25.2 18.6 13.8 62.6 52.8 43.8 33.6 25.2 155 135 115 100 84 69.5 56.4 45.7 – – – – 58 37.7 24.7 19.5 16.0 14.5 155 135 115 100 84 69.5 56.4 45.7 – – – – 11.0 12.8 14.7 16.6 18.6 27.5 29.6 31.6 33.6 35.6 17.7 20 22.5 25.1 27.5 30 32.6 35.3 – – – – 17.3 20.8 24.8 27.5 30.2 31.8 17.7 20 22.5 25.1 27.5 30 32.6 35.3 – – – – 46 48 50 52 54 54 56 58 60 62 36 38 40 42 44 46 48 50 52 – – – 48 54 60 66 72 78 36 38 40 42 44 46 48 50 52 – – – 42.6 32.4 25.8 19.8 15.6 75.6 57 46.8 39 33 180 162 147 131 116 101 81.5 75.6 62.4 – – – 80 55.2 40 30 23.3 18.3 180 162 147 131 116 101 81.5 75.6 62.4 – – – 18.1 20.2 22.2 24 25.8 32.6 34.3 35.8 37.3 38.8 23 25.4 27.8 30.2 32.6 35.1 37.6 40.2 42.7 – – – 19.3 23.6 27.5 32.1 37 42.2 23 25.4 27.8 30.2 32.6 35.1 37.6 40.2 42.7 – – – 70 75 80 – – 75 80 85 – – 54 56 58 60 62 64 66 68 70 72 74 76 – – – – – – 54 56 58 60 62 64 66 68 70 72 74 76 81 33 22.2 – – 127 108 98 – – 222 198 186 180 166 154 142 130 119 108 97.4 87.5 – – – – – – 222 198 186 180 166 154 142 130 119 108 97.4 87.5 10 20 36 50 75 5 15 25 35 55 13 18-1/2 25-1/2 20 13-1/2 19 26-1/2 26 13 18-1/2 25-1/2 21 13-1/2 19 26-1/2 24 14 19 27 27 12 30 46 60 80 5 15 25 35 55 14 13-1/2 13 14 14 10 5 13 25 36 11 20 15 13 26 36 16 32 25 11 22 32 20 44 35 11 21 29 22 64 55 11 22 31 25 29.5 34.5 39.6 – – 39 42.4 45.6 – – 29.1 31.2 34 36.3 38.9 41.6 44.1 46.6 49.3 51.6 54.2 57.1 – – – – – – 29.1 31.2 34 36.3 38.9 41.6 44.1 46.6 49.3 51.6 54.2 57.1 27 28 19-1/2 27 26 19 26-1/2 24 18-1/2 26 23 19-1/2 27 28 19-1/2 28 30 20 5 3-1/2 6-1/2 10 22 36 15 3-1/2 6-1/2 10 24 50 25 3-1/2 6-1/2 10 27 60 35 3-1/2 6-1/2 10 30 10 5 4 7 9 23 20 15 6 10 13 21 32 25 5 8 10 37 44 35 4 7 10 41 64 55 4 7 10 47 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F46 Pressure Spray Set-ups, External Mix, 1/2J Series Features and Benefits Air Caps • The dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. • SUE75 and SU380C are pressure set-ups using pressurized liquids. Flat spray air caps produce a flat spray pattern. • In SU380C, the air and liquid mix internally, while in SUE75, they mix externally. • SU70 is a siphon set-up with the air and siphoned liquid mixing externally. Fluid cap Air cap C B A Flat spray pattern 9" (23 cm) 18" (46 cm) 27" (69 cm) D 8491 gasket 1705 retainer ring Air Atomizing Nozzles 1705 retainer ring and 8491 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Flat Spray (External Mix) Spray Set-up Spray Consists of Set-up Fluid and No. Air Cap Combination SUE75 Fluid Cap 250375 + Air Cap 14356 *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 3 5 7 10 15 Air Air Air Air Air A gph scfm gph scfm gph scfm gph scfm gph scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) 30 138 31 40 180 35 138 34 45 40 138 38 45 138 41.5 45 210 41.5 55 252 180 41.5 50 210 45 60 50 180 45 55 210 48 55 180 48 60 180 51.5 – – – 60 – – – – – 38 – 48 80 306 65 252 51.5 85 306 69 70 252 58 90 306 72 210 51.5 75 252 62 95 306 75 65 210 55 80 252 65 100 306 78 70 210 58 85 252 69 – – – 35 3 50 5 B (in.) C (in.) D (ft.) 8-1/2 14-1/2 20-1/2 19 9 16-1/2 21-1/2 22 55 7 9-1/2 17-1/2 23 23 70 10 9-1/2 18 24 25 90 15 10 19 26 29 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F47 Air Atomizing Nozzles Pressure Spray Set-ups, External Mix, 1/2J Series Performance Data 360° Circular Spray Spray Set-up No. SU380C Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap 251376 + Air Cap 469-6-130160HC *At the stated pressure in psi. Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* Liquid Pressure 10 20 30 40 60 Air Air Air Air Air gph scfm gph scfm gph scfm gph scfm gph scfm Press. Press. Press. Press. Press. 14.0 56.4 12.2 24 104 16.0 36 116 22.4 48 122 27.8 72 128 40.2 16.0 38.4 14.8 26 85.8 18.6 38 98.4 24.8 50 110 29.8 74 116 42.3 18.0 25.8 16.8 28 72.6 20.3 40 85.2 26.5 52 98.4 31.5 76 108 44.3 20 15.6 19.0 30 54.6 22.7 42 73.2 28.9 54 85.8 33.8 78 96.6 46.3 – – – 32 42 24.8 44 72 30.9 56 74.4 36 80 85.8 48.3 – – – 34 30.6 26.8 46 49.8 32.9 58 66 38.3 82 78.6 50.5 – – – 36 24.6 29.3 48 38.4 35 60 55.2 40.1 84 67.8 52.5 – – – 38 7.2 31.8 50 30 37.8 62 44.4 42 86 61.2 54.8 – – – – – – – – – 64 37.2 44.5 90 48 59 – – – – – – – – – 66 20.4 45.8 – – – 360° circular spray pattern Odor control at a compost facility using air atomizing nozzles. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F48 Siphon/Gravity-Fed Spray Set-ups, External Mix, 1/2J Series Air Caps Air cap C B Fluid cap A Round spray pattern 9" (23 cm) 18" (46 cm) 27" (69 cm) Round spray siphon air caps produce a round spray pattern. D 8491 gasket 1705 retainer ring 1705 retainer ring and 8491 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Refer to page F3 for Siphon/Gravity-Fed Liquid Spray Set-ups diagram. Performance Data Round Spray Siphon Set-ups SU70 Fluid Cap 250375 + Air Cap 437 *At the stated pressure in psi. Atomizing Air Liquid Capacity (gallons per hour)* Air Press. Air Capacity scfm Gravity Head (in.) 18 12 6 4 10.0 12.7 – – – 20 18.5 – – – 30 24 – – 40 29.2 – 50 34.8 60 40.1 Spray Dimensions at 8" Siphon Height Siphon Height (in.) 8 12 24 10.7 – – – 22.8 13.9 – – – 32.4 24.8 13.8 – 67.6 58.8 38.8 31.2 22.7 – 79.8 70.5 62.8 43 35.2 27.6 – 81.9 72.1 63.5 45.4 38.3 30.5 9.5 70 46.1 83.2 74.5 66.0 48 41.4 33.9 13.8 80 51.0 84.6 76.2 67.6 49.8 43.2 36 16.5 Air* A (in.) B (in.) C (in.) D (ft.) 20 3 6 8-1/2 20 30 3 6 8-1/2 22 40 3 6 8-1/2 24 50 3 6 8-1/2 26 60 3 6 8-1/2 29 70 3 6 8-1/2 32 80 3 6 8-1/2 35 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F49 Air Atomizing Nozzles Spray Set-up No. Spray Set-up Consists of Fluid and Air Cap Combination Air Atomizing Nozzles Nozzle Bodies/Nozzle Assemblies, 1J Series 1J Series air atomizing Spray set-up 1J 1 3 Shut-off needle assembly 12810 4 1. Retainer ring CP5713 2. Air cap 3. Fluid cap 4. Nozzle body CP5710 1JN 1J 2 Plug CP1706 Features and Benefits 1JN • Range in capacity from 24 to 1740 gph (91 to 6586 l/h). • Available with a shut-off needle. • 1J features liquid and air feeds at opposite ends of the body and are provided with a removable plug so other needle assemblies may be added in the future. 1" NPT or BSPT (F) 1" NPT or BSPT (F) with shut-off needle • 1JN features a manual shut-off needle that enables the flow of liquid to be stopped. Optimization Tips See Also • See page F2 for optimization tips. • Accessories – Air line filters Materials Material http:// – Pressure gauges – Air pressure regulators – Solenoid valves – Liquid pressure regulators – Strainers Ordering Info Material Code Complete Nozzle Assembly Nozzle Type J Nozzle Body* JN Nozzle Bodies 1 JN Inlet Conn. Nozzle Body Assembly Type l l – SS l Spray Set-up Only Spray Set-up + SU159 – l Spray Set-up SS l Nickel-plated Brass (none) l l 303 Stainless Steel SS l l SSBR l l SS BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. l l To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 4371000-SS. Spray Set-ups Nickel-plated Brass Air Cap and 303 Stainless Steel Fluid Cap 303 Stainless Steel Material Code Spray Set-up No. Material Code *Includes retainer and gasket. SU159 – l Spray Set-up No. SS l Material Code To order spray set-up only, use spray set-up number and material code: SU159-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: 1109-6-224-70-SS. To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1JN-SS. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F50 Pressure Spray Set-ups, Internal Mix, 1J Series Features and Benefits Air Caps • For wide angle round, round and flat sprays, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. • When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. • The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Wide angle round, round, and flat spray air caps produce hollow cone, wide angle round spray, round and flat spray patterns. Fluid cap C Air cap B A 12" (30 cm) 30" (76 cm) 48" (122 cm) D 5713 retainer ring Air Atomizing Nozzles 5713 retainer ring must be ordered separately from the spray set-up, but is included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Wide Angle Round Spray Set-up Spray Consists of Spray Set-up Fluid and Pattern No. Air Cap Combination Fluid Cap 4371000 + SU159 Air Cap 1109-6-22470° Wide Angle Round *At the stated pressure in psi. Liquid Capacity (gallons per minute)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 10 20 30 40 60 Air Air Air Air Air A B C D gpm scfm gpm scfm gpm scfm gpm scfm gpm scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) (in.) (in.) (ft.) 12.0 3.2 43 22 5.1 52 32 6.5 64 42 7.7 79 60 10.6 99 14.0 2.4 51 24 4.1 62 34 5.5 75 44 6.7 90 62 9.5 108 16.0 1.7 61 26 3.3 72 36 4.5 86 46 5.7 100 64 8.4 118 – – – 28 2.6 85 38 3.6 96 48 4.9 110 66 7.5 130 – – – 30 2.0 94 40 3.1 106 50 4.2 120 68 6.8 142 – – – 32 1.6 104 42 2.6 116 52 3.6 132 70 6.1 152 – – – – – – 44 2.2 128 54 3.1 140 72 5.5 166 – – – – – – 46 1.8 136 56 2.7 150 74 5.0 178 – – – – – – – – – 58 2.3 164 76 4.5 190 14 26 32 38 46 50 60 60 86 10 20 20 30 30 40 40 60 60 19 21 17 21 16 20 17 22 15 37 40 33 41 33 44 40 47 31 55 59 47 58 49 62 54 67 41 14 19 25 29 37 37 46 42 61 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F51 Air Atomizing Nozzles Pressure Spray Set-ups, Internal Mix, 1J Series Performance Data Round and Flat Spray Spray Set-up Spray Consists of Spray Set-up Fluid and Pattern No. Air Cap Combination SU152 Fluid Cap 4371000 + Air Cap 11091547 Round Liquid Capacity (gallons per minute)* and Air Capacity (standard cubic feet per minute)* SU172 SU155 Fluid Cap 4371000 + Air Cap 11093187 Round Flat Spray Dimensions Liquid Pressure 10 20 30 40 60 A B C D Air Air Air Air Air gpm scfm gpm scfm gpm scfm gpm scfm gpm scfm Air* Liquid* (in.) (in.) (in.) (ft.) Press. Press. Press. Press. Press. 12.0 3.2 43 22 5.1 52 32 6.5 64 42 7.7 79 60 10.6 99 14.0 2.4 51 24 4.1 62 34 5.5 75 44 6.7 90 62 9.5 108 16.0 1.7 61 26 3.3 72 36 4.5 86 46 5.7 100 64 8.4 118 – – – 28 2.6 85 38 3.6 96 48 4.9 110 66 7.5 130 – – – 30 2.0 94 40 3.1 106 50 4.2 120 68 6.8 142 – – – 32 1.6 104 42 2.6 116 52 3.6 132 70 6.1 152 – – – – – – 44 2.2 128 54 3.1 140 72 5.5 166 – – – – – – 46 1.8 136 56 2.7 150 74 5.0 178 – – – – – Fluid Cap 6251000 + Air Cap 11251625 *At the stated pressure in psi. – – – 58 2.3 164 76 4.5 190 12.0 5.92 48.5 20 – 11.0 42.5 30 13.2 55 40 15.1 66 60 18.3 79 14.0 4.40 82 22 9.1 60 32 11.7 69 42 13.8 78 65 15.8 107 16.0 3.45 128 24 7.8 80 34 10.4 85 44 12.6 93 70 13.5 138 18.0 2.75 187 26 6.72 110 36 9.4 102 46 11.6 109 – – – – – – 28 5.95 143 38 8.45 125 48 10.7 125 – – – – – – 30 5.25 183 40 7.75 150 50 9.7 145 – – – 12.0 3.2 43 22 5.1 52 32 6.5 64 42 7.7 79 60 10.6 99 14.0 2.4 51 24 4.1 62 34 5.5 75 44 6.7 90 62 9.5 108 16.0 1.7 61 26 3.3 72 36 4.5 86 46 5.7 100 64 8.4 118 – – – 28 2.6 85 38 3.6 96 48 4.9 110 66 7.5 130 – – – 30 2.0 94 40 3.1 106 50 4.2 120 68 6.8 142 – – – 32 1.6 104 42 2.6 116 52 3.6 132 70 6.1 152 – – – – – – 44 2.2 128 54 3.1 140 72 5.5 166 – – – – – – 46 1.8 136 56 2.7 150 74 5.0 178 – – – – – – – – – 58 2.3 164 76 4.5 190 14 26 32 38 46 50 60 60 86 10 20 20 30 30 40 40 60 60 4 4 4 4 4 4 4 5 4 8 8 9 9 10 9 10 9 10 12 13 13 13 14 14 15 13 15 30 36 41 45 53 54 63 59 83 14 10 6 11 13 25 24 20 6 11 14 30 36 30 6 10 14 35 46 40 6 10 14 42 65 60 6 11 15 50 14 26 32 38 46 50 60 60 86 10 20 20 30 30 40 40 60 60 29 32 23 34 27 37 29 49 25 60 64 50 72 52 72 59 88 63 84 92 70 96 70 104 88 126 92 21 23 26 27 30 30 33 31 39 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F52 Pressure Spray and Siphon/Gravity-Fed Spray Set-ups, External Mix, 1J Series Features and Benefits Air Caps • For flat spray, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. – The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. – When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. – The liquid and compressed air or gas are mixed externally to produce a completely atomized spray. • For round spray, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle. – The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”. – When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed. – Designed to draw liquid through the feed line into the air flow where it is atomized. Flat spray and round spray air caps produce a flat spray pattern and the siphon air caps produce a round spray pattern. C Fluid cap Air cap B A Flat spray pattern Air Atomizing Nozzles 12" (30 cm) 30" (76 cm) 48" (122 cm) 12415 retainer ring D 12415 retainer ring must be ordered separately from the spray set-up, but is included in the standard nozzle assembly. Please contact your sales engineer. Performance Data Flat Spray (External Mix) Spray Set-up No. SUE175B Spray Set-up Consists of Spray Fluid and Pattern Air Cap Combination Fluid Cap 625780 + Air Cap 12116 Flat *At the stated pressure in psi. Liquid Capacity (gallons per minute)* and Air Capacity (standard cubic feet per minute)* Spray Dimensions Liquid Pressure 3 5 7 10 20 25 30 40 50 60 13.0 13.0 13.0 13.0 13.0 13.0 87 101 115 140 166 191 25 30 40 50 60 70 17.0 17.0 17.0 17.0 17.0 17.0 101 115 140 166 191 216 30 40 50 60 70 80 20 20 20 20 20 20 115 140 166 191 216 242 40 50 60 70 80 90 Siphon Set-ups Round Spray Spray Set-up No. SU170 Spray Set-up Consists of Fluid and Air Cap Combination Fluid Cap 6251000 + Air Cap 1125 15 Air Air Air Air Air A B C D gpm scfm gpm scfm gpm scfm gpm scfm gpm scfm Air* Liquid* Press. Press. Press. Press. Press. (in.) (in.) (in.) (ft.) 23 23 23 23 23 23 140 166 191 216 242 268 50 60 70 80 90 – 29 29 29 29 29 – 166 191 216 242 268 – 30 40 50 60 70 3 5 7 10 15 20 22 23 22 22 36 37 39 38 39 47 48 51 49 50 25 28 30 32 35 *At the stated pressure in psi. Atomizing Air Liquid Capacity (gallons per minute)* Spray Dimensions at 8" Siphon Height Air Press. Air Capacity scfm 18 12 6 4 8 12 18 20 25 30 40 60 80 100 105 120 135 165 225 285 345 – 5.2 5.3 5.4 5.5 5.6 5.7 – 4.5 4.6 4.7 4.9 5.0 5.1 3.4 3.6 3.8 3.9 4.2 4.4 4.5 1.9 2.2 2.4 2.6 2.9 3.0 3.1 – – 1.4 1.8 2.2 2.3 2.4 – – – 1.1 1.5 1.6 1.7 – – – – .40 .50 .60 Gravity Head (in.) Siphon Height (in.) Air* A (in.) B (in.) C (in.) D (ft.) 30 5 10 15 29 40 5 10 15 35 60 5 10 15 44 80 5 10 15 54 100 5 10 15 64 Refer to page F3 for Siphon/Gravity-Fed Liquid Set-ups. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F53 Air Atomizing Nozzles Fogger Spray Nozzles, Special Purpose 23412 Features and Benefits QJ25655 • 23412 produces high quality, cost-efficient dry fog. – Drops average fifteen microns in size and less. – Drop size is adjustable to meet specific industrial needs by changing the ratio of compressed air to water. – Maintenance time is reduced because the built-in check valve, spray tip, and internal strainer are quickly serviced without tools. 1/4" NPT or BSPT (F) threaded type – Can use PVC pipe and low-pressure air tubing. Split-eyelet type to clamp on 1/2", 3/4", 1" pipe size – Tip has a relatively large clog-reducing orifice. • QJ25655 provides fast installation of the nozzle onto the liquid supply pipe – no additional pipe fittings are required. – Pipe cutting, threading and brazing are eliminated. – Features a chemical-resistant, tight-fitting Buna-N seal to ensure leak-free performance. Ordering Info Specifications Complete Nozzle Assembly Complete Nozzle Assembly 23412 – 1/4 – 20 QJ25655 – 3/4 – 20 l l l Nozzle Body Inlet Conn. Fluid Orifice Dia. l l l Nozzle Body Pipe Size Fluid Orifice Dia. Nozzle Inlet (in.) AirJet Fogger Type 1/4 23412 Fluid Orifice No. Orifice Dia. Nom. (in.) 16.0 .016 20 .020 26 .026 Fluid Orifice No. Orifice Dia. Nom. (in.) 16.0 .016 20 .020 26 .026 BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. To Clamp On Pipe Size (in.) AirJet Fogger Type 1/2 3/4 QJ25655 1 Humidification to reduce static charge in paint manufacturing plants. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F54 Fogger Spray Nozzles, Special Purpose Performance Data 23412, QJ25655 *At the stated pressure in psi. Fluid Orifice No. 16 (.016" Dia.) Water Pressure 20† 30 40 50 60 70 80 90 100 Fluid Orifice No. 20 (.020" Dia.) Water Pressure Air Pressure* 10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 1.1 – – – – – – 3.1 1.7 – – – – – – 1.5 2.5 – – – – – – 1.4 2.8 – – – – – – 1.7 1.6 1.2 – – – – – 3.6 2.1 1.7 – – – – – 1.4 2.4 3.4 – – – – – 1.3 2.5 3.6 – – – – – 2.0 1.6 1.5 1.4 – – – – 4.3 3.1 2.2 – – – – – 1.4 2.4 3.3 4.2 – – – – 1.2 2.3 3.4 – – – – – 2.1 1.9 1.7 1.5 1.3 – – – 4.9 3.7 3.1 2.3 – – – – 1.4 2.3 3.2 4.2 5.0 – – – 1.2 2.2 3.2 4.2 – – – – 2.3 2.1 1.9 1.7 1.4 1.3 0.8 – – 4.3 3.7 3.1 2.2 – – – 1.3 2.3 3.2 4.1 5.0 5.8 6.8 – – 2.1 3.0 3.9 5.0 – – – 2.6 2.4 2.2 1.9 1.7 1.7 1.5 1.0 – 4.8 4.3 3.6 3.1 2.1 – – 1.3 2.3 3.1 4.0 4.9 5.7 6.7 7.6 – 2.0 2.9 3.8 4.8 5.9 – – 2.7 2.6 2.4 2.2 2.0 1.9 1.7 1.6 – 5.3 4.9 4.2 3.7 3.1 2.2 – 1.3 2.2 3.1 4.0 4.9 5.7 6.6 7.5 – 1.9 2.7 3.6 4.6 5.6 6.7 – 2.9 2.8 2.6 2.4 2.2 2.0 1.9 1.9 – – 5.4 4.9 4.3 3.6 3.1 – 1.2 2.1 3.1 3.9 4.7 5.7 6.5 7.5 – – 2.6 3.5 4.4 5.4 6.5 – 3.1 3.0 2.8 2.6 2.4 2.3 2.2 2.2 – – 5.8 5.3 4.8 4.3 3.7 3.1 1.2 2.1 3.0 3.9 4.7 5.6 6.5 7.5 – – 2.5 3.3 4.3 5.3 5.9 7.3 20† 30 40 50 60 70 80 90 100 *At the stated pressure in psi. †For applications with liquid pressures below 30 psi (2 bar), request end cap sub-assembly 21950-20-NYB. Fluid Orifice No. 26 (.026" Dia.) Water Pressure 30 40 50 60 70 80 90 100 Air Pressure* 1.2 23412, QJ25655 20† *At the stated pressure in psi. In each line, figures in plain face indicate water atomized in gph (l/h) at psi (bar) water pressure. Air Pressure* 10 20 30 40 50 60 70 80 Figures in boldface indicate atomizing air in scfm (Nl/min) at psi (bar) air pressure. 3.3 1.8 – – – – – – 1.3 2.4 – – – – – – AirJet Fogger has a horizontal throwing distance of 15' (4.5 m) and will expand to approximately 8' (2.4 m) wide/3' (.9 m) thick. 4.3 3.4 2.1 – – – – – 1.1 2.1 3.2 – – – – – – 4.5 3.6 2.4 – – – – – 1.9 2.8 3.9 – – – – – 5.3 4.6 3.7 2.5 0.9 – – – 1.8 2.7 3.6 4.7 5.9 – – – 6.1 5.4 4.7 3.8 2.8 1.3 – – 1.7 2.5 3.4 4.4 5.4 6.7 – – – 6.2 5.5 4.8 4.0 3.0 1.7 – – 2.4 3.3 4.2 5.1 6.2 7.4 – – 6.8 6.2 5.5 4.8 4.1 3.1 – – 2.3 3.2 4.1 5.0 5.9 7.0 – – 7.4 6.9 6.3 5.6 5.0 4.3 – – 2.2 3.0 3.9 4.8 5.6 6.6 – – 7.9 7.4 6.9 6.3 5.7 5.0 – – 2.1 2.9 3.8 4.6 5.5 6.4 1. Values in blue area show optimum evaporation under normal room conditions, when center line of spray is 5' (1.5 m) from the lower surface. 2. Values in red area can require up to 10' (3 m) for evaporation. Other values may be used where extended heat, higher air velocity exist or where slight surface wetting is permitted. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F55 Air Atomizing Nozzles 23412, QJ25655 Air Atomizing Nozzles DripSafe™ Special Purpose Fogger Spray Nozzles, Features and Benefits • High-volume/high-efficiency air atomization. • Air requirements are met using an air compressor with a capacity range that is suitable for the application. • Produces an adjustable, high-quality dry fog without wetting with pressure-fed liquid. • Requires minimal maintenance. • Ideal for large/open structures and areas with high air exchange rates. • The flat spray tip has a large orifice that reduces clogging. • Operation is through a drip safe air-actuated liquid shut-off valve. • Spray set-up and built-in strainer are quickly removed by hand if cleaning is required. • Automatically prevents liquid from spraying until air pressure at the nozzle is sufficient for fine atomization. • Spray tip is brass; valve and body polymer. • Drip safe valve simplifies system construction and control while improving performance. • Operates at pressures up to 100 psi (7 bar) with a minimum air pressure range of 25 to 35 psi (1.7 to 2.5 bar). • Operates using normal water pressures found in municipal water systems, eliminating the need for expensive, high-pressure hydraulic pumps. • A split-eyelet or saddle clamp version of the AirJet Fogger (45269 Series) is also available for quick and easy mounting to the liquid supply pipe. 45265 Optimization Tips 45269 • See page F2 for optimization tips. Applications 1/4" NPT or BSPT (F) • Evaporative cooling • Insecticide spraying • Fogging • Plant propagation • Humidification Split-eyelet type to clamp on pipe 1/2" to 1" See Also Specifications Nozzle Inlet Conn. (in.) 1/4 To Clamp On Pipe Size (in.) AirJet Fogger Type 45265 AirJet Fogger Type 1/2 3/4 1 45269 Fluid Orifice No. Orifice Dia. Nom. (in.) 16.0 .016 20 .020 26 .026 Fluid Orifice No. Orifice Dia. Nom. (in.) 16.0 .016 20 .020 26 .026 • Accessories – Air line filters http:// – Pressure gauges – Air pressure regulators – Solenoid valves – Liquid pressure regulators – Strainers • For 23412 and QJ25655, request Data Sheets 23412 and 25635 • For 45265 and 45269, request Data Sheets 45265-1-2 and 45269-1-2 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F56 DripSafe™ Special Purpose Fogger Spray Nozzles, Performance Data 45265, 45269 *At the stated pressure in psi. Fluid Orifice No. 16 (.016" Dia.) Water Pressure 20 30 40 Fluid Orifice No. 20 (.020" Dia.) Water Pressure Air Pressure* 10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 1.1 – – – – – – 3.1 1.7 – – – – – – 1.5 2.5 – – – – – – 1.4 2.8 – – – – – – 1.7 1.5 1.2 – – – – – 3.6 2.1 1.7 – – – – – 1.4 2.4 3.4 – – – – – 1.3 2.5 3.6 – – – – – 2.0 1.7 1.5 1.4 – – – – 4.3 3.1 2.2 – – – – – 1.4 2.4 3.3 4.2 – – – – 1.2 2.3 3.4 – – – – – 20 30 40 *At the stated pressure in psi. In each line, figures in plain face indicate water atomized in gph (l/h) at psi (bar) water pressure. Fluid Orifice No. 26 (.026" Dia.) Water Pressure 30 40 Air Pressure* 1.2 45265, 45269 20 *At the stated pressure in psi. Figures in boldface indicate atomizing air in scfm (Nl/min) at psi (bar) air pressure. Air Pressure* 10 20 30 40 50 60 70 80 3.3 1.8 – – – – – – 1.3 2.4 – – – – – – 4.3 3.4 2.1 – – – – – 1.1 2.1 3.2 – – – – – – 4.5 3.6 2.4 – – – – – 1.9 2.8 3.9 – – – – 1. Values in blue area show optimum evaporation under normal room conditions, when center line of spray is 5' (1.5 m) from the lower surface. 2. Values in red area can require up to 10' (3 m) for evaporation. Other values may be used where extended heat, higher air velocity exist or where slight surface wetting is permitted. 3. AirJet Fogger has a horizontal throwing distance of 15' (4.5 m) and will expand to approximately 8' (2.4 m) wide/3' (.9 m) thick. Ordering Info Complete Nozzle Assembly Complete Nozzle Assembly 45265 – 1/4 – 16 l l l Nozzle Body Inlet Conn. Fluid Orifice Dia. 45269 – 1/2 – 16 l l l Nozzle Body Pipe Size Fluid Orifice Dia. BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F57 Air Atomizing Nozzles 45265, 45269 Air Atomizing Nozzles Humidification Spray Nozzles and Units Features and Benefits • All equipment supplied for humidification systems except piping and wiring. • YMF MiniFogger® III is ideal for humidification applications with limited space due to its compact design. – Available with a choice of one to four stainless steel spray nozzle set-ups with a wide variety of flow-rate sizes/droplet sizes and types. • 1/4JH siphon air atomizing nozzles provide automatic, efficient humidity control with low installation and operating costs. – Nozzles operate either with compressed air drawing water from the float box by siphon action, or with water being delivered to the nozzle under pressure. – For each spray set-up, water capacity is 0.26 to 1.19 gph (1.0 to 4.5 l/h), and air capacity is 30 to 35 nl/min at 43.5 psi (3.0 bar). – Produces a fine atomized spray for rapid evaporation and efficient humidification. – Can be placed in hard-to-reach spaces and can be easily installed on a header, on a wall or on a ceiling. – For information on siphon set-ups, see pages F23 to F53. • 1/4JT pressure-fed air atomizing nozzles provide automatic, efficient humidity control with low installation and operating costs. – 0.46 lbs. (210 g) for single spray set-up type; 0.55 lbs. (250 g) for multiple four set-up types. – Height is 4.53" (115 mm). – Suitable for use in systems where water is under pressure. – The body, retainer cap, and tank are made of corrosionresistant polypropylene with stainless steel air and water connections. – Have built-in strainers for air and water plus a ball check valve in the water line. – Materials are also compatible with deionized water. – Produces a fine atomized spray for rapid evaporation and efficient humidification. • 46215-008 provides a finely atomized spray without the use of compressed air. – Produces a hollow cone spray pattern. – For information on pressure set-ups, see pages F5 to F48. • 45400 humidification unit is a self-contained humidifier suitable for use with deionized water (DI). – Easy to install on a wall or for use in non-ducted applications. – Requires a minimum liquid pressure of 450 psi (31 bar) to the nozzle. – Maximum operating pressure of 1000 psi (69 bar). – Air regulator and gauge, 24VDC air control solenoid and air line filter are included within the Humidification Unit. – Wall-mounting bracket is also provided. – 9.7 lbs. (4.4 kg). – For each spray set-up, water capacity ranges from 2.7 lbs./hr at 10 psi (0.7 bar) air to 6.5 lbs./hr at 60 psi (4 bar) air. 1/4JH 45400 YMF 46215-008 Siphon inlet connection 1/4" NPT and BSPT inlets 1/4JT 1/4" NPT or BSPT (F) MiniFogger III 1/4" NPT or BSPT (F) air and liquid inlet connection 1/8" NPT or BSPT (F) misting nozzle Pressure-fed inlet connection 1/4" NPT and BSPT inlets Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F58 Humidification Spray Nozzles and Units Optimization Tips Materials • See page F2 for optimization tips. Material Code Material See Also http:// Nozzle Type JH JT 45400 YMF 46215 Nozzle Bodies – Air pressure regulators Brass (none) – Pressure gauges Nickel-plated Brass (none) – Solenoid valves Kynar® KY 303 Stainless Steel – Liquid pressure regulators – Strainers • For 1/4JH siphon air atomizing nozzles, request Data Sheet 10188 • For 1/4JT pressure-fed air atomizing nozzles, request Data Sheet 2843 l l SS l l Nickel-plated Brass SSBR l l Nickel-plated Brass Air Cap and 303 Stainless Steel Fluid Cap SSBR l l l l l Air/Fluid Caps • For 45400 humidification unit, request Data Sheet 45400 • For YMF MiniFogger® III, request Data Sheet YMF Performance Data l Kynar KY 303 Stainless Steel SS PTFE TEF l l l Ordering Info YMF MiniFogger III Data per Nozzle (Air Pressure 0.3 MPa) Orifice Set-up Air Mean Spray Diameter Liquid No. Capacity Capacity Droplet Size Distance (in.) gph scfm (micron)* (ft.) SU2.5N 0.02 .66 1.2 8.5 8.8 *Sauter Mean Diameter 0.1 MPa = 1 bar 1/4 JH – SS l l l Inlet Conn. Nozzle Body Material Code Spray Set-up + SU1A – l Spray Set-up No. SS l Material Code Humidification Unit YMF-3 – l Humidification Unit Type 4 l No. of Set-ups *Includes retainer and gasket. 45400 46215-008 Atomizing Air Complete Nozzle Assembly Nozzle Body* Water Capacity Air Press. psi Air Capacity scfm gph 10 .38 .32 20 .57 .42 30 .74 .52 40 .92 .62 50 1.10 .71 60 1.30 .78 BSPT connections require the addition of a “B” prior to the nozzle body inlet connection. Pressure psi Liquid Capacity gph 500 .94 To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 1650-SS. 600 1.0 700 1.1 To order air cap only, use air cap number (shown in performance data charts) and material code: 64-SS. 800 1.2 900 1.25 1000 1.3 To order spray set-up only, use spray set-up number and material code: SU1A-SS. Humidification Unit 45400 – l Humidification Unit Type 1 l No. of Set-ups To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1/4JH-SS. Typical humidifying set-ups for siphon nozzles B A A – Float box with float valve B – TW liquid strainer C – Air atomizing nozzle D – Spray pipe assembly E – Pipe hanger F – Air filter G – Pressure regulator with gauge H – Solenoid valve I – Switching relay J – Humidistat C I D E J G F H Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F59 Air Atomizing Nozzles • Accessories – Air line filters Air Atomizing Nozzles Humidification System Components Features and Benefits • 2335-SE pipe assembly consists of straight and formed tubing with fittings, globe valve and split-eyelet connectors. – Not assembled. • 11438-85 humidistat will respond to humidity levels in the range of 20% to 95% RH. – Maximum operating temperature 125°F (52°C). 24V DC; 110V. Overall height 6" (15 cm). • 11438-95 switching relay has built-in transformer that supplies low-voltage current for humidistat circuit. – 2-wire 24V control, 115V AC. Maximum temperature 115°F (46°C). • 55089 electric humidistat quick relative humidity LCD readouts from 1% to 99% with repeatability of ±5%. – Operating temperature range 32°F to 160°F (0°C to 71°C). – 24V (DC or AC). • 45604 float valve used in 45600 float box to shut off inlet flow at a preset water level. – Made of ABS plastic, 304 Stainless Steel, polypropylene with fiber washers and a brass nut. • 55400 valve package is easy to install and use – simply connect to existing air and fluid lines. – The NEMA type 4 panel is completely sealed to eliminate moisture damage to components. – Safety feature ensures there is no product damage due to unintentional water release. – Stainless steel components available for use with deionized water. – Separate atomizing and cylinder air lines with adjustable delay time assures liquid atomization. • 2202 pipe hanger for proper spacing between air and liquid lines. Sizes fit 1/2" piping. – Hanger is held by threaded rod and nuts (not included) for vertical adjustment. – Made of cast aluminum. 4" (10 cm) spacing. – Use with 2335-SE spray pipe assembly. See Also • Accessories – Air line filters Optimization Tips • See page F2 for optimization tips. http:// – Pressure gauges – Air pressure regulators – Solenoid valves – Liquid pressure regulators – Strainers • Section L, Accessories • For 2335-SE pipe assembly, request Data Sheet 2335-SE • For 55089 electrical humidistat, request Data Sheet 55089 2335-SE Spray pipe assembly 45604 Float valve 11438-85 11438-95 Humidistat Switching relay 45600 55400 Float box Valve package 55089 Electric humidistat 2202 Pipe hanger Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F60 Air Atomizing Accessories Features and Benefits • 22140 pressure tank assembly meets ASME® Boiler and Pressure Vessel Code requirements and OSHA safety regulations. – Constructed of 304 Stainless Steel. • 39272 tank heater bands provide anywhere from 6°F to 60°F (3°C to 33°C) heat gain depending upon the tank size and number of bands used. – Silicone rubber construction with fiberglass mesh reinforcement for added strength, flexibility, and corrosion resistance. – Assembly includes a pressure regulator with gauge, ASME coded pressure relief valve, air bleed valve and plug valves for air inlet and liquid outlet. – Features quick-release band clasp and built-in thermostat for temperature control. – Tanks are available in 1, 2, 5 and 10 gallon (3.8, 7.6, 18.9 and 38 liter) capacities. – Two sizes fit 9" and 12" (288.6 and 304.8 mm) diameter tanks. – The air inlet and liquid outlet have 1/4" NPT (F) connections. • 38673 push-in tube fittings provide fast and easy hook-up of air atomizing nozzles. – The maximum working pressure is 140 psi at 100°F (9.5 bar at 38°C). – Select from six configurations with 1/8", 1/4" or 3/8" NPT (M) connections for 1/4", 3/8" and 1/2" O.D. tubing. • 45592 ferrule-type tube fittings are intended for use when operating at higher pressures. – The 316 Stainless Steel is of durable construction and can be easily taken apart for cleaning. – Recommended pressure is up to 250 psi (17 bar) for liquid and air lines. – Six configurations available with 1/8", 1/4" or 3/8" NPT connections for 1/4", 3/8" and 1/2" O.D. tubing. • 38691 and 38692 strong, semi-rigid nylon tubes designed for use with 38673 fittings. – Abrasion resistant and dimensionally stable tubing available in 12', 25' and 50' (3.6 m, 7.5 m and 15 m) lengths. – Fits 1/2", 3/4" or 1" pipe or similar O.D. tube. 1/4" NPT or BSPT (M) outlet pipe connections. – Nickel-plated brass with zinc-plated pipe clamps or all stainless steel construction. • 39273, 39275 level switch kit indicates a low liquid level condition inside the pressure tank. – Use standard 39273 level switch with 5 and 10 gallon (18 and 38 liter) pressure tank assemblies with external 1/4" NPT (F) threads. – Maximum working pressure is 250 psi (17 bar) at –40°F to +70°F (–40°C to +20°C). – 38691 has 1/4" O.D. – 38692 has 3/8" O.D. – Use 39275 level switch with 1 and 2 gallon (4 and 8 liter) pressure tank assemblies with external 1/4" NPT (F) threads. – Features a U.L. listed float switch, quick disconnect and 12' (3 m) PVC jacketed cable. – Available in brass with Buna-N float or all stainless steel. Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F61 Air Atomizing Nozzles – Durable nickel-plated brass construction includes Buna-N O-ring. – The 22140 features brass fittings and an EPR lid seal. • 38180 split-eyelet swivel union simplifies installation and maintenance of air atomizing nozzles and spray guns. – Connector design reduces costs by eliminating cutting, threading, welding and brazing operations and adjustment of fittings, unions and nipples. Air Atomizing Nozzles Air Atomizing Accessories 22140 Pressure tank assembly 38180 Split-eyelet swivel union 39273 and 39275 Level switch kit 38673 and 45592 Tube fittings 39272 Tank heater bands Optimization Tips See Also • See page F2 for optimization tips. • For 22140 pressure tank assembly, request Data Sheet 22140 http:// • For 38180 split-eyelet swivel union, request Data Sheet 38180 • For 39273, 39275 level switch kit, request Data Sheet 39275 and 39273 • For 39272 tank heater bands, request Data Sheet 39272 • For 38673, request Data Sheet 38673 • For 45592 ferrule-type tube fittings, request Data Sheet 45592 • For 38691 and 38692, request Data Sheets 38691 and 38692 Phone 1-800-95-spray, FAX 1-888-95-spray Visit Our Web Site: www.spray.com, Email: [email protected] F62
Similar documents
Section F – Air Atomizing Spray Nozzles
• For 1/4JDLN and 1/4JDLCO, request Data Sheet 7690 • For 20470 Series hand-held air atomizing spray guns, request Data Sheets 20470J, 20470JN, 20470JMCO, 20470JN-1, 20470JJ, 20470JJN and 20470JJNT...
More information