The Belmont Rapid Infuser RI-2

Transcription

The Belmont Rapid Infuser RI-2
780 Boston Road
Billerica, MA 01821 USA
T: 866.663.0212
F: 978.663.0214
www.belmontinstrument.com
Technical
Assistance Hotline
1.855.397.4547
The Belmont
Rapid Infuser RI-2
Worldwide
978.663.0212
Hardware Specifications
MILITARY
Dimensions
13.5 in. x 7.5 in. x 12 in.
342.9 mm. x 190.5 mm. x 304.8 mm.
Weight
28 lb.
12.7 kg
Portability
Quick-on IV pole mount/handle at top
of unit
EMERGENCY & CRITICAL CARE
Power
115 volt or 220/240 volt AC input
120 ml Reservoir
3.0 Liter Reservoir
Battery
Internal, rechargable for transport
Operates all functions without heating
Order Information
Fluid Pump
Roller type peristaltic pump
Rapid Infuser RI-2, 1000 ml/min
Infusion rate: 2.5-1000 ml/min
Flow rate 2.5-1000 ml/min
Heater
Maximum applied power, 1440 watts
US: Part #903-00037 (120V)
International: Part #903-00037A (230V)
Sensors
Rapid Infuser RI-2, 750 ml/min
Infusion rate: 2.5-750 ml/min
OPERATING ROOM
2 air detectors, pressure transducer, 2
temperature probes (infrared sensing),
US: Part #903-00039 (120V)
International: Part #903-00039A (230V)
pump infusion rate sensor, open door
detector, and valve activation sensors
3-Spike Disposable Set
Control Computer
Part #903-00006
Built-in, controls all functions
Redundant hardware override protection
3.0 Liter Reservoir
in case of computer failure
Part #903-00018
Display
Patient Line Extension
LCD type with waterproof touch pad
Part #903-00022
External Dimensions
5.85 in. x 4.12 in.
Dual Patient Line
Part #903-00004
L & D AND PEDIATRICS
148.1 mm. x 104.7 mm
Active Area
4.53 in. x 3.40 in.
115.1 mm. x 86.3 mm
Belmont Instrument Corporation
Registered to ISO 13485
File Number: A18173
UL 60601-1
CAN/CSA-C22.2 No. 601.1
ANSI/AAMI/ES60601-1 (2005)
CAN/CSA-C22.2 No. 60601-1 (2008)
The Belmont® Rapid Infuser, RI-2, has been evaluated with respect to electrical shock, fire and
mechanical hazards in accordance with UL 60601-1, CAN/CSA-C22.2 No. 601.1, ANSI/AAMI/ES60601-1
(2005, 3rd ed.), CAN/CSA-C22.2 No. 60601-1 (2008), Electromagnetic Compatibility [EN60601-1-2
(2007) and IEC 60601-1-2 (2007)].
© Belmont Instrument Corporation
701-00136 Rev. E
Infuse in seconds
Save a life
The
Rapid Infuser RI-2
We understand that urgent moment when you need to safely and rapidly infuse
blood or fluids.
We know you need to:
Have quick
and easy
setup
Trust that all
air has been
removed
Know the exact
temperature of
the blood/fluid
being infused
Be alerted
when something
needs immediate
attention to keep
your patient
safe
Easy to Use – Large graphical display and simplified touch screen make the system easy to use and gives clear troubleshooting instructions.
There is also a screen to show how to load the disposable set for users that do not use the infuser often.
Receive immediate
and personal
customer service
Vent/Recirculation Line
Touch screen display
The Belmont RI-2 offers you:
Input Air Detector
• A patented inductive heater provides instant heat
without water baths or hot plates
Output
Temperature
Probe
• Step by step on-screen instructions
High Speed Peristaltic Pump
• Automatic priming in seconds
• Automatic air removal with two air detectors
one at input and another at output
• Precise control of infusion with settings from 2.5
ml/min to 1000 ml/min
Pressure Sensor/Debubbler
• A large simple touch screen that continuously
displays fluid temperature, total volume infused, line
pressure, and both target and actual infusion rates
The Belmont Rapid Infuser RI-2 Delivered Temperature (500ml/minute)
Heat
Exchanger
Output Air Detector
40
• Automatic alarms avoid unsafe conditions if the
line becomes obstructed, when you are out of fluid
and when other conditions occur
Infuse/Recirculation Valve
• An extra long 15 foot power cord for increased mobility
Input Temperature Probe
TEMP (CENTIGRADE)
30
• Operator controlled bolus infusion
20
10
• Several languages to choose from
• Easy transport - lightweight and compact
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
TIME (SECONDS)
Input Temp
Display Temp
Patient Line Temp
Unique Instant Heating - No “Hot Spots”
1
CALL 866.663.0212 OR EMAIL [email protected] FOR MORE INFORMATION
BELMONT INSTRUMENT CORPORATION
2