standard drawings water standard drawings
Transcription
standard drawings water standard drawings
UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed Date 02/1/16 STANDARD DRAWINGS WATER STANDARD DRAWINGS Title Drawing Number Fire Hydrant and Appurtenance Locations, Improved Streets with Curb Fire Hydrant and Appurtenance Locations, Unimproved Streets without Curbs Existing Water Service Abandonment 6-Inch High Pressure Fire Hydrant (above 200 psi minimum design pressure) Below-Ground Blow-Off (Potable or Reclaimed) Super Fire Hydrant Assembly (Steel Pipe) Super Fire Hydrant Assembly (PVC Pipe) 6-Inch Fire Hydrant Assembly (Steel Pipe) 6-Inch Fire Hydrant Assembly (PVC Pipe) 1-Inch Air Vac and Air Release Assembly 2-Inch Air Vac and Air Release Assembly Above-Ground 4-Inch Air Vac and Air Release Assembly for Steel Pipe Interim Unmetered Construction Water Details 1-Inch Copper Service Lateral 2-Inch Copper Service Lateral CML&C Steel Service Lateral (4”, 6”, 8”, and 12”) PVC Service Lateral (4”, 6”, 8”, and 12”) Typical Drop-in Meter Installation Dual Service (Fireflow & Domestic) Meter Assembly – Below-Grade (4”, 6”, 8”, and 10”) Turbine or Compound Meter Assembly – Below-Grade (3”, 4”, 6”, and 8”) Reduced Pressure Principle Backflow Prevention Assembly 2-Inch and Smaller Reduced Pressure Principle Backflow Prevention Device 3-Inch and Larger Double Check Backflow Prevention Device – 3-Inch and Larger Above-Ground Fire Service & Backflow Prevention Assembly (DCDA or RPDA) Below-Grade Double Check Detector Assembly PVC Pipe Installation Steel Casing for Steel or PVC Pipe Water Pipeline End Cap Installation (PVC) Water Pipeline Dead End Hydrant CML&C Steel Pipe Installation Change Legend: Revised Drawing Strike-out Current Date RW-1 01/2012 RW-1A RW-2 RW-3A RW-4 RW-5 RW-6 RW-7 RW-8 RW-9 RW-10 RW-11 RW-12 RW-13 RW-14 RW-15 RW-15A RW-16 01/2012 04/2014 12/2015 01/2012 12/2015 12/2015 12/2015 12/2015 01/2012 01/2012 01/2012 01/2012 01/2012 01/2012 01/2012 01/2012 01/2012 RW-17 RW-17A RW-18 RW-19 RW-19A RW-20 RW-21 RW-22 RW-23 RW-24 RW-24A RW-25 01/2012 01/2012 06/2012 01/2012 01/2012 02/2016 01/2012 01/2012 01/2012 01/2012 01/2014 01/2012 UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed Date 02/1/16 WATER STANDARD DRAWINGS (Continued) Title Drawing Number Thrust/Support Block Details Thrust Block Detail – Shear Ring for CML&C Steel Pipe Standard Restraint for Tees, Dead Ends, and Bends for PVC (C-900/C905) Concrete Encasement and Concrete Cap (8” – 16” Pipe) Weld Saddle and Service Saddle Fabricated Fittings and Tapping Flange Outlet Valve Cap and Riser Detail Valve Cap and Riser Detail (Plug Valves) Buried Valve Detail Buttstrap with Hand Hole Welded Steel Pipe Weld Detail for CML&C Steel Pipe Rubber Gasket, CML&C Steel Pipe Joints Steel Cylinder Pipe Bonded Joints Pipe Support Detail Water Quality Sample Station Cathodic Protection Test Station Cathodic Protection Test Station w/Reference Cell Cathodic Protection Test Station w/Prepackaged Sacrificial Anode Cathodic Protection Test Station w/Insulated Flange or Casing Telemetering Terminal Housing Chlorination Piping, Well Discharge Piping Chain Link Fence Detail Advance Notification Sign Alumino-Thermic Weld CP Test Box and Locator Wire Box Cathodic Protection and Locator Wire Labeling and Terminating Electrolysis Protection at Steel Pipeline Crossing Magnesium Anode and Reference Electrode Details Dual Service (Fireflow & Domestic) Meter Assembly - Above-Grade (4”, 6”, 8”, and 10”) Turbine or Compound Meter Assembly - Above-Grade (3”, 4”, 6”, and 8”) Change Legend: Revised Drawing Strike-out Current Date RW-26 RW-26A RW-26B RW-27 RW-28 RW-29 RW-30 RW-30A RW-31 RW-32 RW-33 RW-34 RW-35 RW-36 RW-37 RW-38 RW-40 RW-40A RW-40B RW-41 RW-42 RW-43 RW-44 RW-45 RW-46 RW-47 01/2009 02/2011 02/2011 02/2011 03/2008 03/2008 02/2011 01/2012 01/2012 01/2012 01/2012 01/2012 01/2012 02/2011 03/2008 01/2009 01/2009 08/2009 01/2009 01/2009 01/2009 02/2011 08/2009 06/2009 03/2008 06/2009 RW-48 RW-49 RW-50 01/2009 01/2009 01/2009 RW-51 RW-51A 01/2012 06/2012 UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed Date 02/1/16 STANDARD DRAWINGS SEWER STANDARD DRAWINGS Title Pipe Zone Bedding and Trench Backfill Concrete Caps and Encasement Sewer Connection at Concrete Encasement Sewer Lateral Normal Cut Sewer Lateral Deep Cut Sewer Lateral V.C.P. Saddle Connection Sewer Lateral Plastic Pipe Saddle Connection Connecting Dissimilar Sewer Pipes Residential Cleanout Sewer Chimney Lateral Sewer Tree Laterals and Cleanouts Precast Reinforced Eccentric Concrete Manhole Terminus Manhole with House Laterals Manhole Cover and Frame - Standard and Water Tight 36-Inch Two-Piece Manhole Cover and Frame – Standard and Water Tight Paving Detail around Manholes Manhole Cover and Frame - Locking Type Sewer Cleanout – Main Line 36-Inch I.D. Sampling Manhole NOT USED Typical Metering Manhole Metering Manhole Telemetry Pipe Casing Sewer Main Sewer Main Crossing Existing Water Sand/Oil Separator Sample Box #1 (Industrial) Sample Box #2 (Commercial) Grease Interceptor Sampling Wye Sewage Backflow Valve Assembly Change Legend: Revised Drawing Strike-out Drawing Number S- 1 S- 2 S- 3 S- 4 S- 5 S- 6 S- 7 S- 8 S- 9 S-10 S-11 S-12 S-13 S-14 S-14A S-15 S-16 S-17 S-18 S-19 S-20 S-21 S-22 S-23 S-24 S-25 S-26 S-27 S-28 S-29 Current Date 03/2008 03/2008 03/2008 02/2011 03/2008 03/2008 03/2008 03/2008 02/2011 03/2008 03/2008 03/2008 03/2008 03/2008 03/2008 01/2009 03/2008 03/2008 03/2008 02/2011 02/2011 03/2008 03/2008 03/2008 03/2008 03/2008 03/2008 03/2008 03/2008 Rancho California Water District Rancho California Water District Rancho California Water District Rancho California Water District Rancho California Water District Rancho California Water District