standard drawings water standard drawings

Transcription

standard drawings water standard drawings
UPDATE LOG FOR STANDARD DRAWINGS
Item(s) Changed
Date
02/1/16
STANDARD DRAWINGS
WATER STANDARD DRAWINGS
Title
Drawing Number
Fire Hydrant and Appurtenance Locations, Improved Streets with Curb
Fire Hydrant and Appurtenance Locations,
Unimproved Streets without Curbs
Existing Water Service Abandonment
6-Inch High Pressure Fire Hydrant (above 200 psi minimum design pressure)
Below-Ground Blow-Off (Potable or Reclaimed)
Super Fire Hydrant Assembly (Steel Pipe)
Super Fire Hydrant Assembly (PVC Pipe)
6-Inch Fire Hydrant Assembly (Steel Pipe)
6-Inch Fire Hydrant Assembly (PVC Pipe)
1-Inch Air Vac and Air Release Assembly
2-Inch Air Vac and Air Release Assembly
Above-Ground 4-Inch Air Vac and Air Release Assembly for Steel Pipe
Interim Unmetered Construction Water Details
1-Inch Copper Service Lateral
2-Inch Copper Service Lateral
CML&C Steel Service Lateral (4”, 6”, 8”, and 12”)
PVC Service Lateral (4”, 6”, 8”, and 12”)
Typical Drop-in Meter Installation
Dual Service (Fireflow & Domestic) Meter Assembly – Below-Grade (4”, 6”,
8”, and 10”)
Turbine or Compound Meter Assembly – Below-Grade (3”, 4”, 6”, and 8”)
Reduced Pressure Principle Backflow Prevention Assembly 2-Inch and Smaller
Reduced Pressure Principle Backflow Prevention Device 3-Inch and Larger
Double Check Backflow Prevention Device – 3-Inch and Larger
Above-Ground Fire Service & Backflow Prevention Assembly (DCDA or RPDA)
Below-Grade Double Check Detector Assembly
PVC Pipe Installation
Steel Casing for Steel or PVC Pipe
Water Pipeline End Cap Installation (PVC)
Water Pipeline Dead End Hydrant
CML&C Steel Pipe Installation
Change Legend:
Revised Drawing
Strike-out
Current Date
RW-1
01/2012
RW-1A
RW-2
RW-3A
RW-4
RW-5
RW-6
RW-7
RW-8
RW-9
RW-10
RW-11
RW-12
RW-13
RW-14
RW-15
RW-15A
RW-16
01/2012
04/2014
12/2015
01/2012
12/2015
12/2015
12/2015
12/2015
01/2012
01/2012
01/2012
01/2012
01/2012
01/2012
01/2012
01/2012
01/2012
RW-17
RW-17A
RW-18
RW-19
RW-19A
RW-20
RW-21
RW-22
RW-23
RW-24
RW-24A
RW-25
01/2012
01/2012
06/2012
01/2012
01/2012
02/2016
01/2012
01/2012
01/2012
01/2012
01/2014
01/2012
UPDATE LOG FOR STANDARD DRAWINGS
Item(s) Changed
Date
02/1/16
WATER STANDARD DRAWINGS (Continued)
Title
Drawing Number
Thrust/Support Block Details
Thrust Block Detail – Shear Ring for CML&C Steel Pipe
Standard Restraint for Tees, Dead Ends, and Bends for PVC (C-900/C905)
Concrete Encasement and Concrete Cap (8” – 16” Pipe)
Weld Saddle and Service Saddle
Fabricated Fittings and Tapping Flange Outlet
Valve Cap and Riser Detail
Valve Cap and Riser Detail (Plug Valves)
Buried Valve Detail
Buttstrap with Hand Hole
Welded Steel Pipe
Weld Detail for CML&C Steel Pipe
Rubber Gasket, CML&C Steel Pipe Joints
Steel Cylinder Pipe Bonded Joints
Pipe Support Detail
Water Quality Sample Station
Cathodic Protection Test Station
Cathodic Protection Test Station w/Reference Cell
Cathodic Protection Test Station w/Prepackaged Sacrificial Anode
Cathodic Protection Test Station w/Insulated Flange or Casing
Telemetering Terminal Housing
Chlorination Piping, Well Discharge Piping
Chain Link Fence Detail
Advance Notification Sign
Alumino-Thermic Weld
CP Test Box and Locator Wire Box
Cathodic Protection and Locator Wire Labeling
and Terminating
Electrolysis Protection at Steel Pipeline Crossing
Magnesium Anode and Reference Electrode Details
Dual Service (Fireflow & Domestic) Meter Assembly - Above-Grade (4”, 6”, 8”,
and 10”)
Turbine or Compound Meter Assembly - Above-Grade (3”, 4”, 6”, and 8”)
Change Legend:
Revised Drawing
Strike-out
Current Date
RW-26
RW-26A
RW-26B
RW-27
RW-28
RW-29
RW-30
RW-30A
RW-31
RW-32
RW-33
RW-34
RW-35
RW-36
RW-37
RW-38
RW-40
RW-40A
RW-40B
RW-41
RW-42
RW-43
RW-44
RW-45
RW-46
RW-47
01/2009
02/2011
02/2011
02/2011
03/2008
03/2008
02/2011
01/2012
01/2012
01/2012
01/2012
01/2012
01/2012
02/2011
03/2008
01/2009
01/2009
08/2009
01/2009
01/2009
01/2009
02/2011
08/2009
06/2009
03/2008
06/2009
RW-48
RW-49
RW-50
01/2009
01/2009
01/2009
RW-51
RW-51A
01/2012
06/2012
UPDATE LOG FOR STANDARD DRAWINGS
Item(s) Changed
Date
02/1/16
STANDARD DRAWINGS
SEWER STANDARD DRAWINGS
Title
Pipe Zone Bedding and Trench Backfill
Concrete Caps and Encasement
Sewer Connection at Concrete Encasement
Sewer Lateral Normal Cut
Sewer Lateral Deep Cut
Sewer Lateral V.C.P. Saddle Connection
Sewer Lateral Plastic Pipe Saddle Connection
Connecting Dissimilar Sewer Pipes
Residential Cleanout
Sewer Chimney Lateral
Sewer Tree Laterals and Cleanouts
Precast Reinforced Eccentric Concrete Manhole
Terminus Manhole with House Laterals
Manhole Cover and Frame - Standard and Water Tight
36-Inch Two-Piece Manhole Cover and Frame – Standard and Water Tight
Paving Detail around Manholes
Manhole Cover and Frame - Locking Type
Sewer Cleanout – Main Line
36-Inch I.D. Sampling Manhole
NOT USED
Typical Metering Manhole
Metering Manhole Telemetry
Pipe Casing Sewer Main
Sewer Main Crossing Existing Water
Sand/Oil Separator
Sample Box #1 (Industrial)
Sample Box #2 (Commercial)
Grease Interceptor
Sampling Wye
Sewage Backflow Valve Assembly
Change Legend:
Revised Drawing
Strike-out
Drawing Number
S- 1
S- 2
S- 3
S- 4
S- 5
S- 6
S- 7
S- 8
S- 9
S-10
S-11
S-12
S-13
S-14
S-14A
S-15
S-16
S-17
S-18
S-19
S-20
S-21
S-22
S-23
S-24
S-25
S-26
S-27
S-28
S-29
Current Date
03/2008
03/2008
03/2008
02/2011
03/2008
03/2008
03/2008
03/2008
02/2011
03/2008
03/2008
03/2008
03/2008
03/2008
03/2008
01/2009
03/2008
03/2008
03/2008
02/2011
02/2011
03/2008
03/2008
03/2008
03/2008
03/2008
03/2008
03/2008
03/2008
Rancho California Water District
Rancho California Water District
Rancho California Water District
Rancho California Water District
Rancho California Water District
Rancho California Water District