a0-1 ups - mira loma ii - healthcare tenant
Transcription
a0-1 ups - mira loma ii - healthcare tenant
RGA SHEET INDEX ARCHITECTURAL A0-1 A0-2 A1-1 A2-1 A2-2 A3-1 A5-1 AD-1 AD-2 TITLE SHEET GENERAL NOTES SITE PLAN OVERALL FLOOR PLAN ROOF PLAN EXTERIOR ELEVATIONS FINISH SCHEDULE DETAILS DETAILS Office of Architectural Design 15231 Alton Parkway, Suite 100 Irvine, CA 92618 STRUCTURAL S-1 S-2 S-3 SD-1 SD-2 EXISTING FOUNDATION PLAN EXISTING ROOF FRAMING PLAN EXISTING PANEL ELEVATIONS DETAILS DETAILS R1 OF 5 R2 OF 5 R3 OF 5 R4 OF 5 R5 OF 5 TITLE, GENERAL NOTES & TABLE OF CONTENTS PARTIAL ROOF FRAMING PARTIAL ROOF FRAMING LOAD & REINFORCEMENT PROFILE REINFORCEMENT DETAILS MECHANICAL M0-1 M0-2 M0-3 M2-1 M2-1A M2-1B M2-2 M2-2A M2-2B M3-1 M4-1 M5-1 LEGEND, SCHEDULE AND NOTES TITLE 24 COMPLIANCE FORMS TITLE 24 COMPLIANCE FORMS MECHANICAL OVERALL FLOOR PLAN MECHANICAL DUCT LAYOUT PLAN MECHANICAL DUCT LAYOUT PLAN MECHANICAL OVERALL ROOF PLAN MECHANICAL ROOF PLAN MECHANICAL ROOF PLAN MECHANICAL SECTIONS DETAILS CONTROL PLAN PLUMBING P0-1 P1-1 P2-1 P2-1A P2-1B P2-1C P2-2 P2-2A P2-2B LEGEND, SCHEDULE, NOTES AND DETAILSs SITE PLAN PLUMBING OVERALL FLOOR PLAN PLUMBING FLOOR PLAN PLUMBING FLOOR PLAN PLUMBING FLOOR PLAN PLUMBING OVERALL ROOF PLAN PLUMBING ROOF PLAN PLUMBING ROOF PLAN ELECTRICAL E-1 E-2 E-3 E-4 E-5 E-6 E-7 SYMBOL LIST AND NOTES SINGLE LINE DIAGRAM WAREHOUSE POWER DEMO PLAN WAREHOUSE LIGHTING DEMO PLAN WARHOUSE LIGHTING PLAN ROOF TOP POWER PLAN ENERGY CALCULATIONS T 949-341-0920 FX 949-341-0922 CONSULTANT PROFESSIONAL SEALS WINEVILLE CENTER POINTE SOUTH BUILDING 2 TENANT IMPROVEMENT FOR UPS SUPPLY CHAIN SOLUTIONS 11811 LANDON DRIVE SUITE 100 MIRA LOMA, CA 91752 PHASE 3 UPS - MIRA LOMA II - HEALTHCARE TENANT IMPROVEMENT UPS SUPPLY CHAIN SOLUTIONS 12380 MORRIS ROAD ALPHARETTA, GA 30005 678-746-4006 PROJECT DATA ARCHITECT: PLUMBING CONTRACTOR: RGA, OFFICE OF ARCHITECTURAL DESIGN 15231 ALTON PARKWAY, SUITE 100 IRVINE, CA 92618 PHONE: 949-341-0920 FAX: 949-341-0922 E-MAIL: [email protected] CONTACT: MIKE GILL TKSC MECHANICAL ENGINEERS 17911 VON KARMAN AVENUE, SUITE 250 IRVINE, CA 92614 PHONE: 949-756-0565 FAX: 949-756-0927 E-MAIL: [email protected] CONTACT: JOHN TRAN ELECTRICAL CONTRACTOR: PMD ENGINEERING 4770 VON KARMAN AVENUE IRVINE, CA 92660 PHONE: 949-222-1203 FAX: 949-222-0324 E-MAIL: [email protected] CONTACT: JOHN DAVIS OCCUPANCY EXISTING NET SITE AREA BUILDING AREA: EAST OFFICE AND WAREHOUSE AREA: EXISTING OFFICE/WAREHOUSE AREA: EXISTING WAREHOUSE AREA (ADDING HVAC TO EXISTING SPACE) TOTAL WEST TI AND WAREHOUSE AREA: EXISTING HEALTHCARE WAREHOUSE AREA #1,2,3 EXISTING UPS MEDTRONIC WAREHOUSE AREA: EXISTING UPS MEDTRONIC TI NORTHWEST CONDITIONED BREAK ROOM EXISTING UPS MEDTRONIC TI NORTHWEST CONDITONED RESTROOM EXISTING RACK MEZZANINE AREA: EXISTING TOTAL BUILDING FOOT PRINT (OFFICE & WAREHOUSE AREA) EXISTING RACK MEZZANINE AREA: TOTAL OFFICE /WAREHOUSE BUILDING + EXISTING MEZZANINE: EXISTING NET COVERAGE: EXISTING SITE LANDSCAPING: PROVIDED AREA: PARKING REQUIRED: EXISTING OFFICE/WAREHOUSE PARKING EXISTING NORTHWEST OFFICE 476 SF @ 1/250 EXISTING NORTHWEST MEZZANINE 5,100 SF @ 1/2000 TOTAL PARKING REQUIRED: 1,500,966 SF 34.46 AC 847,847 SF 19.46 AC 78,362 SF 156,346 SF 234,708 SF 110,456 SF 54,162 SF 476 SF 450 SF 5,100 SF 400,252 SF 5,100 SF 405,352 SF 47.21% 113,929 SF 205 STALLS 2 STALLS 3 STALLS 210 STALLS SPRINKLERED CONSTRUCTION TYPE AREA JUSTIFICATION: BASIC ALLOWABLE SINGLE STORY SPRINKLER INCREASE X 3 4 SIDEYARD PROVIDED @ 60'-0" (THE BUILDING IS ENTIRELY SURROUNDED AND ADJOINED BY 60' YARDS FOR UNLIMITED ALLOWABLE FLOOR AREA) 5/9/12 80% REVIEW SET 6/5/12 ADDENDUM 1 TYPE III - B (FORMERLY TYPE III - N) 12,000 SF 36,000 SF UNLIMITED AREA BUILDING CLEAR HEIGHT TO THE LOWEST STRUCTURAL MEMBER 32'-0" CLEAR MISSION BLVD. CITY OF ONTARIO RIVERSIDE COUNTY 60 1 PLANNING DEPARTMENT PLOT PLAN NUMBER # PP16937 ZONE CHANGE # 6588 EXISTING BUILDING DEPARTMENT PERMIT # BNR 050138 EXISTING TENANT IMPROVMENT PERMIT # BTI-050219 COUNTY ZONING: IP EIR: 442 (EIR 442) AND EA37900 PARCEL MAP NO: 34826 ASSESSOR PARCEL NUMBERS APN: 160-040-0344 LEGAL DESCRIPTION VAN RIVERSIDE BID BUR EN 60 BL VD HARREL ST. FUTURE CANTU-GALLEANO RANCH ROAD 15 FUTURE CANTU GALLEANO RANCH ROAD EUCALYPTUS AVE. CANTU GALLEANO RANCH ROAD . DD 4/5/12 DESIGN DEVELOPMENT SD 3/13/12 SCHEMATIC DESIGN MARK DATE DESCRIPTION RGA PROJECT NO: 11189-00 OWNER PROJECT NO: 00000.00 CAD FILE NAME: 11189-00-A0-1 DRAWN BY: MG CHK'D BY: DR RGA, OFFICE OF ARCHITECTURAL DESIGN SHEET TITLE COVER SHEET E RAV LEG PLAN CHECK COPYRIGHT AV. BEL BID SET 5/24/12 PC DR. A PORTION OF THE NORTH 139.07 AC OF THE NORTHEAST 1/4 OF FRACTIONAL SECTION 18, TOWNSHIP 2 SOUTH, RANGE 6 WEST, SAN BERNARDINO BASE & MERIDIAN CONSTRUCTION SET CD REFERENCE NUMBERS 1. THIS PROJECT SHALL COMPLY WITH CALIFORNIA CODE OF REGULATIONS TITLE 24 INCLUDING: 203 STALLS 7 STALLS 210 STALLS 30% REVIEW SET FULLY SPRINKLERED: ESFR GENERAL NOTES PARKING PROVIDED: EXISTING 9 X 18' STANDARD STALLS EXISTING ACCESSIBLE STALLS TOTAL AUTO STALLS 4/5/12 B , S-1 ETIWANDA AVE. PHONE: FAX: E-MAIL: CONTACT: TKSC MECHANICAL ENGINEERS 17911 VON KARMAN AVENUE, SUITE 250 IRVINE, CA 92614 PHONE: 949-756-0565 FAX: 949-756-0927 E-MAIL: [email protected] CONTACT: LARRY SUN EXISTING SITE AREA: EXISTING GROSS SITE AREA AVE. TDB EXISTING AREA JUSTIFICATION WINEVILLE GENERAL CONTRACTOR: MECHANICAL CONTRACTOR: PROJECT DATA RD. AON CORPORATION 3505 KOGER BLVD., SUITE 175 DULUTH, GA 30096 PHONE: 770-225-9689 FAX: 770-381-9539 E-MAIL: [email protected] CONTACT: MICHAEL BANHAM RIVERSIDE COUNTY HSA & ASSOCIATES, INC. 16700 VALLEY VIEW SUITE 220 LA MIRADA, CA 90638 PHONE: 714-522-0030 FAX: 714-522-0040 E-MAIL: [email protected] CONTACT: AJIT RANDHAVA FUTURE PRIVATE UUPS SUPPLY CHAIN SOLUTIONS 11991 LANDON DRIVE JURUPA VALLEY, CA 91752 PHONE: 951-749-3123 FAX: 951-749-3024 E-MAIL: [email protected] CONTACT: MARCO AIRO AVE. FIRE PROTECTION ENGINEER: MILLIKEN STRUCTURAL ENGINEER: S.B. COUNTY OWNER: VICINITY MAP HAMNER AVE. PROJECT DIRECTORY SITE AREA 2010 CALIFORNIA BUILDING CODE (CBC) 2010 CALIFORNIA MECHANICAL CODE (CMC) 2010 CALIFORNIA ELECTRIC CODE (CEC) 2010 CALIFORNIA PLUMBING CODE (CPC) 2010 CALIFORNIA ENERGY CODE 2010 CALIFORNIA FIRE CODE (CFC) OPTION 2 PLAN 2. NO EXTERIOR TENANT SIGNAGE IS PROPOSED FOR THE PROJECT AS PART OF THIS PERMIT APPLICATION. SEPARATE PERMITS SHALL BE REQUIRED FOR ALL SIGNS. 3. YARDS USED FOR AREA INCREASE SHALL BE PERMANENTLY MAINTAINED. SHEET: A0-1 KEYNOTES EXISTING TO BE REMAIN RGA 000 1. EXISTING PUBLIC STREET, CURB, AND GUTTER PER COUNTY STANDARDS. 2. EXISTING DRIVEWAY CURB. 3. EXISTING PARCEL LOT LINE. APPROVED UNDER PREVIOUS PERMIT. 4. EXISTING 12' HT. CONCRETE TILT-UP SCREEN WALL 5. EXISTING STREET FIRE HYDRANT. Office of Architectural Design 6. EXISTNG DBL. DETECTOR CHECK VALVE. 1 15231 Alton Parkway, Suite 100 Irvine, CA 92618 7. EXISTING ACCESSIBLE PARKING STALL COMPLIANCE SIGNAGE AT DRIVEWAY ENTRANCES INTO SITE. SEE DETAIL 2/AD-1. 8. EXISTING ON-SITE FIRE HYDRANT. A R O N A E L L A G TU N CA 2 7 6 H NC A RO D 10. EXISTING ACCESSIBLE PATH OF TRAVEL FROM STALLS & PUBLIC WAY TO PRIMARY ENTRANCE. SLOPE NOT TO EXCEED 1:20 EXCEPT AT CURB RAMPS AND OTHER DEFINED RAMPS. CROSS SLOPE NOT TO EXCEED 1/4" PER FOOT. SEE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL DATA. STRIPE PAVING W/ WHITE PAINT AT ALL DRIVEWAY CROSSINGS. 11 9 22 27 14. POSSIBLE LOCATION FOR TRASH COMPACTOR / BAILER LOCATION TO BE INSTALLED . 31 H 1 FH 16 EXISTING GAS LINE 11 15. EXISTING CONCRETE TRUCKING APRON . 5 H EXISTING GAS LINE 21 H H H H FH 1 GM 29 RD 32 20 NOT A PART MEDTRONIC USA, INC SUITE 300 xx RD DS 138'-0" TRUCK COURT DS UPS SUITE 100 EXISTING DEMISING WALL RD 6 17 600'-0" 130'-0" TRUCK COURT DS FH DS 12 18 15 UPS SUITE 100 430.82' DS PROPERTY LINE 14 NOT TRASH COMPACTOR A PART DS 26. NEW GAS METER LOCATION PER THE GAS COMPANY, SEE PLUMBING DRAWINGS. CONTRACTOR TO COORDINATE THE EXACT LOCATION AND REQUIREMENTS WITH THE GAS COMPANIES STANDARDS. 53'-0" 27. INDICATES (1) EXISTING GENERATOR. 28. CONTRACTOR TO REMOVE LOUVERS IN CONCRETE WALLS AT WEST AND NORTH LOCATION. INFILL HOLES IN TILT UP PANEL WITH METAL STUD AS REQUIRED. PROVIDE DRYVIT SYSTEM. NEW FINISH FOR EACH FACE OF STUD TO MATCH EXISTING CONCRETE TILT-UP PANEL. PAINT TO MATCH BUILDING. SEE ELEVATIONS BELOW FOR LOCATIONS. INSULATE WALL AS REQUIRED. 28 8 DS 24. INDICATES AREA OF NEW TENANT IMPROVEMENT. SEE ENLARGED PLAN FOR ADDITIONAL INFO. 25. NEW GAS LINE, SEE PLUMBING DRAWINGS. RAMP UP DS EXISTING CONCRETE TILT-UP OFFICE/ MANUFACTURING/ WAREHOUSE BUILDING TYPE III-B B / S-1 OCCUPANCY FULLY-SPRINKLED(ESFR SYSTEM) 28 24 29.RESTORE ALL LANDSCAPE AND IRRIGATION TO EXISTING STANDARDS TO MATCH EXISTING AFTER THE INSTALLATION OF THE NEW GAS LINE AND METER. SEE PAVING DETAIL ON ARCHITECTURAL AND PLUMBING DRAWINGS. 30. INDICATES EXISTING WROUGHT IRON FENCING . 31. EXISTING GAS LINE PER THE GAS COMPANY AND PLUMBING DRAWINGS. 32. EXISTING TENANT IMPROVEMENT AREA. DS DS UPS SUITE 100 15 670'-0" EXISTING DEMISING WALL 18 DS WINEVILLE CENTER POINTE SOUTH BUILDING 2 TENANT IMPROVEMENT FOR UPS SUPPLY CHAIN SOLUTIONS 11811 LANDON DRIVE SUITE 100 MIRA LOMA, CA 91752 DS DS PROFESSIONAL SEALS 22. EXISTING STANDARD PARKING STALL 9' X 18' W/ + 2' OVERHANG - STRIPE PER COUNTY STANDARDS. TYP. 23. EXISTING ON SITE LIGHT POLES. PATIO AVENUE 1 10 WINEVILLE DS 20. EXISTING INTERIOR FIRE PUMP ROOM SERVING BUILDING'S ESFR SYSTEM. 21. EXISTING ACCESSIBLE PARKING STALL PER STATE AND ADA ACCESSIBILITY STANDARDS. 13 12'-0" HIGH SCREENWALL 25 18. EXISTING DOCK HIGH LOADING DOOR. 19. EXISTING ELECTRICAL ROOM & ELECTRICAL SWITCHGEAR. SEE ELECTRICAL DRAWINGS. NEW GAS LINE 26 19 16. EXISTING TRANSFORMER AND VAULT. SEE ELECTRICAL DRAWINGS FOR IMPROVEMENTS. 17. EXISTING GRADE LEVEL LOADING DOOR. H FH 12. EXISTING CONCRETE TILT-UP OFFICE/ WAREHOUSE FACILITY. 13. PRIMARY BUILDING ENTRANCE - ACCESSIBLE PER ADA & T-24 GUIDELINES. WITH EXISTING ADA ACCESSIBLE SIGNAGE. FH 30 CONSULTANT 11. EXISTING CONCRETE SIDEWALK. 4 DS T 949-341-0920 FX 949-341-0922 9. EXISING SHADED AREA INDICATES : FULLY IRRIGATED LANDSCAPING. NOTE WHERE NEW STAIRS ARE PROVIDE FOR EXIT ACCESS OUT OF BUILDING ADJACENT TO NEW TI AREAS CONTRACTOR TO PROVIDE NEW CONCRETE SIDEWALK. SEE PLAN FOR ADDITIONAL INFO. 28 PHASE 3 DS 4 DS DS FH FH UPS SUITE 100 NOT A PART 23 DS DS DS DS 7 FH FH PROPERTY LINE 35'-0" 3 2 UPS SUPPLY CHAIN SOLUTIONS 985.68' 12380 MORRIS ROAD ALPHARETTA, GA 30005 678-746-4006 SITE PLAN SCALE: 1" = 60'-0" GENERAL NOTES 1. ALL DIMENSIONS ARE TO FACE OF CONCRETE CURB, FACE OF CONCRETE PANEL, OR TO GRIDLINE U.N.O. 2. KNOX BOX KEY ACCESS IS PROVIDED AT THE PRIMARY BUILDING ENTRANCES AND AT ALL SITE GATES. 3. ALL EXISTING IMPROVEMENTS SHOWN RECENTLY PERMITED. SITE AND BUILDING ARE FULLY ACCESSIBLE UNDER CURRENT STATE GUIDELINES. ALL EXISTING ACCESSIBLE COMPLYING PARKING STALLS, WALKS , RAMPS AND ENTRANCES ARE SUBJECT TO FIELD VERIFICATION. 4. WALK SURFACES WITH A SLOPE OF LESS THAN 5% GRADIENT SHALL HAVE A MEDIUM BROOM OR EXPOSED AGGREGATE FINISH WITH A SLIP RESISTANCE EQUAL TO A MED. SALT FINISH U.N.O. WALK SURFACES WITH A SLOPE OF GREATER THAN 6% GRADIENT SHALL BE SLIP RESISTANT PER DISABLED ACCESS STANDARDS. ACCESSIBLE WALK CROSS SURFACE SLOPES SHALL NOT EXCEED 1/4" PER FOOT OR 2%. 5. ANY ABRUPT LEVEL CHANGES SHALL BE LESS THAN OR EQUAL TO 1/2" ALONG ANY ACCESSIBLE ROUTE OF TRAVEL. WHEN CHANGES DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE OF LESS THAN OR EQUAL TO 1:2. LEVEL CHANGES OF 1/4" MAX MAY BE VERTICAL. IF LEVEL CHANGES ARE GREATER THAN 1/2", THEY MUST COMPLY WITH THE REQUIREMENTS OF CURB RAMPS. 6. YARDS USED FOR AREA INCREASE SHALL BE PERMANENTLY MAINTAINED. 1 4/5/12 30% REVIEW SET 5/9/12 80% REVIEW SET 6/5/12 ADDENDUM 1 CONSTRUCTION SET CD BID BID SET 5/24/12 PLAN CHECK PC DD 4/5/12 DESIGN DEVELOPMENT SD 3/13/12 SCHEMATIC DESIGN MARK DATE DESCRIPTION RGA PROJECT NO: 11189-00 OWNER PROJECT NO: 00000.00 CAD FILE NAME: 11189-00-A1-1 DRAWN BY: MG CHK'D BY: MG COPYRIGHT RGA, OFFICE OF ARCHITECTURAL DESIGN SHEET TITLE SITE PLAN OPTION 2 PLAN SHEET: A1-1 A B 60'-0" E D C 40'-0" 50'-0" G F 50'-0" 50'-0" H 600'-0" 50'-0" 50'-0" J K 50'-0" M L 50'-0" 50'-0" O N 40'-0" 60'-0" KEYNOTES RGA 000 1. EXISTING CONCRETE EXTERIOR WALL SYSTEM. 2. EXISTING GLAZING SET IN ALUMINUM STOREFRONT SYSTEM. 8' 3. EXISTING ACCESSIBLE PRIMARY ENTRANCE WITH APPROVED ACCESSIBILITY SIGNAGE PER DETAIL 8 / AD-1. Office of Architectural Design 4. EXISTING OFFICE TI. NOT A PART OF THIS PERMIT. 5. EXISTING ADA COMPLYING WAREHOUSE RESTROOMS A96 2 FR 44'-0" FR A99 1 16 2 A100 EXIT A101 FR DS E 2 9. NOT USED. 10. NOT USED. 3 13. CONTRACTOR TO PROVIDE VERSA FLEX FLOOR JOINT CAULKING OR APPROVED EQUAL THROUGHT OUT NEW WAREHOUSE SPACE. DEFINED BY FULL HT. WALLS. THIS SHALL OCCURE IN WAREHOUSE SPACE 101. 54'-0" 54'-0" 14. PROVIDE 18" WIDE VECTOR STRIP WHITE EXPOSY PAINT AROUND INSIDE WAREHOUSE FULL HEIGHT PERIMETER WALLS, COPUTER ROOM AND OFFICE WALLS. SEE PLAN FOR LOCATIONS. A92 MEDTRONIC USA, INC SUITE 300 NOT A PART DS A90 14 15. INDICATES EXISTING EXIT SIGNS. INSTALLED UNDER SHELL PERMIT. EXIT EGRESSES THROUGH WAREHOUSE AREA PER CBC SECTION 1004.2.2. ONE FOOTCANDLE ILLUMINATION ALONG EXIT ACCESS. 4 A03 A88 A87 DS A86 16. INDICATES EXISTING ROOF ACCESS LADDER LOCATION INSTALLED UNDER SHELL PERMIT. A04 20 54'-0" 5 EXISTING 1 HOUR WALL 54'-0" A89 5 RD A02 FORKLIFT RAMP UP EXIT FR EXIT 4 PATIO EXIT A91 17. EXISTING FIRE RISER LOCATIONS INSTALLED UNDER SHELL PERMIT. A05 18. EXISTING ELECTRICAL SWITCHGEAR AND TELEPHONE BACKBOARD LOCATION . A06 19. EXISTING STEEL ROOF COLUMN. CONTRACTOR TO FURR OUT ROOF COLUMNS AT FULL HT. DEMISING WALLS WHICH OCCURE IN AREA OF NEW WORK. SEE DETAIL. 5 DS 21. EXISTING DOCK VERTICAL LIFT DOOR ASSEMBLY. SEE GENERAL NOTE BELOW FOR ADDITIONAL INFO. 54'-0" 54'-0" A08 A84 6 23. INDICATES EXISTING CHEVRON BRACES. NOTE WHERE CHEVRON BRACE COMES IN CONTACT W/ DEMISING WALL CONTRACTOR TO WRAP CHEVRON BRACE W/ 3/4" TYPE "X" GYP. BD. ASSEMBLY PER WALL LEGEND TO COMPLETE 1 HR. ASSEMBLY. A10 DS EXIT 15 54'-0" A80 6 11 24. EXISTING SANITARY SEWER BELOW FLOOR SLAB. A11 25. AREA OF TENANT IMPROVEMENTS. A12 26. INDICATES NEW FULL HEIGHT NON-RATED DEMISING WALL. BOTH SIDES OF WALL TO BE PRIMERED AND PAINTED TO MATCH EXISTING. PROVIDE R-19 BATT INSULATION THOUGHOUT THE WALL CAVITY FROM FLOOR TO ROOF STRUCTURE. SEE STRUCTURAL DRAWINGS FOR STUD WALL SIZE AND GAUAGE. ALSO SEE STRUCTURAL DRAWINGS COLUMN LINE AND END WALL EXPANSION JOINTS. PROVIDE ALTERNATE PRICING FOR METAL INSULATED PANEL IN LIEU OF THE METAL STUDS AND DRYWALL. PANEL MANUFACTURE TO BE: METLSPAN, CF MESA WALL PANEL CF42MM-26/26, 6" THICK, R-30 INSULATION VALUE MIN., HEIGHT TO SPAN 42'-6". MOUNT TO UNDERSIDE OF ROOF STRUCTURE WITH THE REQUIRED BLOCKING AND TRACK PER MANUFACTURES RECOMMENDATION. INTERIOR FACING, AZ-50 ALUMINUM-ZINC COSTED STEEL, PAINT COLOR TO BE POLAR WHITE STANDARD COLOR. 54'-0" UPS SUITE 100 NOT A PART A81 DS FR EXIT A82 A13 1 7 A79 7 22. EXISTING 3'W X 7'H PAINTED SELF CLOSING HOLLOW METAL MAN DOOR. CONTRACTOR TO PROVIDE TACTILE EXIT SIGNAGE REQUIREMENTS. SEE DET 16/AD-1. A09 A83 DS A14 7 DS 13 A78 A15 21 A77 27. NEW ROLL-UP DOOR ASSEMBLY . SEE DOOR SCHEDULE FOR SIZE AND REQUIREMENTS TO COMPLY WITH RATED AND NON- RATED CONDITIONS. CONTRACTOR TO PROVIDE AND INSTALL BOLLARD AT EACH END OF DOOR TO PROTECT DOOR TRACK AND WALL. PROVIDE 6" DIA CONCRETE FILLED BOLLARDS. SEE DETAIL 9/AD-1. 54'-0" 54'-0" A16 TYP. 14 A76 A17 23 DS EXIT OCCUPANCY: B/ S-1 OCCUPANT LOAD: 1,530 A73 54'-0" 700'-0" BUILDING 2 EXIT A74 A72 A71 8 11 A20 A22 9 DS UPS 101 A23 A69 54'-0" 54'-0" A24 14 A25 1. INTERIOR FIRE HOSE AND EXTINGUISHER LOCATIONS SHALL BE PER FIRE PROTECTION DRAWINGS AND AS APPROVED BY FIRE DEPARTMENT. A67 A26 2. CONTRACTOR TO PROTECT FLOOR SLAB DURING CONSTRUCTION AND KEEP CLEAN AT ALL TIMES. ALL VEHICLES ON SLAB DURING CONSTRUCTION SHALL BE DIAPERED TO PREVENT OIL SPILLS. 22 FR EXIT EXIT A66 DS FR 13 AD-1 54'-0" A65 20 AD-2 16 AD-2 3'3' 5' 10' A64 27 17 AD-1 1 11 AD-2 14 7 AD-2 25 26 9 /10 AD-2 28'-8" 27 1 17'-4" 16 AD-2 A28 24'-0" 11 EXISTING NON-RATED WALL DS A61 54'-0" UPS SUITE 100 NOT A PART A60 A59 DS 1 NEW NON-RATED WALL 2 3 A31 4 A33 12 DS EXIT EXIT A58 A36 54'-0" 54'-0" A56 A37 102 A55 A38 DS 13 DS A53 A40 A52 A41 A51 A42 EXIT WOMENS RESTROOM 5 MENS RESTROOM MENS RESTROOM 1'-7" 15 EXIT A50 5 EXIT EXIT A49 EXIT A48 EXIT A47 EXIT A46 EXIT A45 MENS RESTROOM MENS RESTROOM 14 DS FR FR 11. TENANT'S SHALL SECURE ALL SEPARATE PERMITS THAT ARE REQUIRED FOR ALL STORAGE PLANS, RACK INSTALLATIONS, AND CONVEYOR INSTALLATIONS. 13. CONTRACTOR SHALL SEAL ALL CRACKS IN FLOOR WHICH OCCURES IN WAREHOUSE SPACE 101. A43 30'-5" DS WOMENS RESTROOM 15 1'-7" 14 9. PENETRATIONS OF FIRE RESISTIVE WALLS, FLOOR/CEILING AND ROOF/CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC CHAPTER 10. 12. A SEPARATE PERMIT IS REQUIED FOR SPRINKLER MODIFICATIONS TO EXISTING SYSTEM. 54'-0" A39 54'-0" A54 6. BUILDING IS DESIGNED FOR HIGH PILE STORAGE COMMODITY CLASSES ONE THROUGH FOUR. TENANTS SHALL SECURE ALL SEPARATE PERMITS WHICH ARE REQUIRED FOR ALL STORAGE PLANS, RACK INSTALLATIONS, AND CONVEYOR INSTALLATIONS. 10. REPAIR ALL FLOOR SLAB CUTS WITH NEW 4,000 PSI 7" THK. CONCRETE SLAB O/ 4" ROCK BASE. REPAIR VAPOR BARRIER WHERE DAMAGED. PROTECT EXISTING SLAB REINFORCING BARS IN PLACE, OR REPLACE WITH MATCHING. ANY REMOVAL AND REPLACEMENT OF THE CONCRETE SLAB SHALL MEET THE REQUIREMENTS OF THE EXISTING SLAB. TRENCH BACKFILL SHALL BE COMPACTED TO 95% ASTM D-1 557 MAXIMUM DRY DENSITY. DOWEL THE NEW CONCRETE PATCH TO THE EXISTING SLAB WITH #4 STEEL BARS EXTENDING A MIN. OF 6" INTO SLAB AT 24" O.C. SECURE WITH EPOXY. USE 4000 P.S.I. (AT 28 DAYS) CONCRETE FOR THE POUR BACK. ANY TRENCH PATCHING IN THE WAREHOUSE AREA SHALL HAVE A 1/8 INCH RADIUS EDGE. PRIOR TO POURING CONCRETE, STONE THE EXISTING SAW CUT EDGE WITH AN ABRASIVE BRICK OR OTHER METHOD TO APPROXIMATE A 1/8 INCH RADIUS EDGE. A35 EXISTING WAREHOUSE AREA NOT A PART A57 12380 MORRIS ROAD ALPHARETTA, GA 30005 678-746-4006 8. ALL PENETRATIONS THROUGH BUILDING ARE TO BE CAULKED ON BOTH THE INTERIOR AND EXTERIOR OF THE WALL. A34 FR UPS SUPPLY CHAIN SOLUTIONS 7. ALL FLOOR SLAB NAIL HOLES SHALL BE FILLED WITH APPROVED 2 PART EPOXY COMPOUND TO MATCH CONCRETE COLOR. PEGA BOND LV 2000, BURKE EPOXY INJECTION RESIN OR APPROVED EQUAL. A32 54'-0" A62 13 5. NO "READY MIX" TRUCKS WILL BE PERMITTED TO DRIVE OR OPERATE ON ANY PORTION OF THE BUILDING FLOOR SLAB. A MAXIMUM OF AN 8 CUBIC YARD "READY MIX" TRUCK MAY BE ALLOWED ON THE FLOOR SLAB FOR PERIMETER CLOSURE STRIP CONCRETE PLACEMENT WITH PRIOR APPROVAL OF THE OWNER. A30 DS 12 4. ALL DOOR OPENING DIMENSIONS GIVEN ARE FINISH OPENING SIZES. CONTRACTOR SHALL ADJUST OPENING FOR JAMB AND SILL ASSEMBLIES ACCORDINGLY. A29 A63 11 3. ALL DIMENSIONS ARE TO FACE OF CONCRETE WALL, STRUCTURAL GRID LINE, OR CENTERLINE OF STUD/COLUMN U.N.O. A27 13 AD-1 10' 5' 3' 10 11 54'-0" DS 30'-5" GENERAL NOTES A68 10 16 PHASE 3 A21 DS A70 UPS SUPPLY CHAIN SOLUTIONS 11811 LANDON DRIVE SUITE 100 MIRA LOMA, CA 91752 A19 UPS SUPPLY CHAIN SOLUTIONS SUITE 100 28 9 DS FR 54'-0" 8 A18 1 HOUR WALL WINEVILLE CENTER POINTE SOUTH BUILDING 2 TENANT IMPROVEMENT FOR 700'-0" A75 PROFESSIONAL SEALS 20. EXISTING GRADE LEVEL ROLL-UP DOOR ASSEMBLY. A07 A85 CONSULTANT 12. NOT USED. RD 4 T 949-341-0920 FX 949-341-0922 11. CONTRACTOR TO REMOVE EXISTING LOUVERS IN CONCRETE TILT-UP WALL INFILL OPENINGS WITH CONCRETE. SEE STRUCTURAL DRAWING FOR DETAIL. FORM REVEAL AT HEAD OF OPENING TO MATCH EXISTING HORIZONTAL REVEAL MARK. SACK AND PATCH PANEL , REPAINT TO MATCH. SEE PLAN FOR LOCATION. EXISTING OFFICE AREA NOT A PART 14 8. NOT USED. A01 RD XIT 1 3 A93 3 7. EXISTING POLISHED HARD STEEL TROWEL FINISHED FLOOR SLAB: 7" THK. 4,000 PSI OVER 95% COMPACTED SUBGRADE. REPAIR ALL CUTS PER GENERAL NOTES THIS SHEET. EXIT EXIT 15231 Alton Parkway, Suite 100 Irvine, CA 92618 6. NOT USED. EXIT EXIT EXIT EXIT A97 17 4'-8" A94 24 44'-0" 18 A44 1 4/5/12 30% REVIEW SET 5/9/12 80% REVIEW SET 6/5/12 ADDENDUM 1 CONSTRUCTION SET CD BID 5/24/12 BID SET PLAN CHECK PC DD 4/5/12 DESIGN DEVELOPMENT SD 3/13/12 SCHEMATIC DESIGN MARK DATE DESCRIPTION RGA PROJECT NO: 11189-00 OWNER PROJECT NO: 00000.00 CAD FILE NAME: 11189-00-A2-1 DRAWN BY: MG CHK'D BY: MG COPYRIGHT 16 RGA, OFFICE OF ARCHITECTURAL DESIGN SHEET TITLE FLOOR PLAN 60'-0" 40'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 40'-0" 60'-0" 9 &10 AD-2 7 AD-2 TYP. 5 AD-3 19 600'-0" FLOOR PLAN A B C D E F G OPTION 2 PLAN H J K L M N SCALE: 1" = 30'-0" SHEET: A2-1 MAXIMUM PARTITION HEIGHT ROOF STRUCTURE - SEE STRUCT. DWGS. STUD SIZE ROOF TRUSS PROVIDE OVERLAPPING GYP. BD. AT FIRE RATED ASSEMBLIES ONLY U.N.O. SECURE TO 20 GA 1.5" X 1.5" CONT. ANGLE SHOT TO STEEL TRUSS @ 18" O.C. STUD SPACING 6" MIN 1" 2" 1" WALL HEIGHT STUD SPACING WALL HEIGHT 362S125-18 (25 GA) 16" 13'-6" 24" 10'-9" 362S125-33 (20 GA) 16" 20'-0" 24" 16'-3" 600S125-33 (20 GA) 16" 28'-6" MECHANICAL EQUIPMENT 600S125-43 (18 GA) 16" 33'-0" 3/4" WOOD SHIM 800S162-54 (16 GA) 16" 40'-0" 0.188" 1 1/4" 3" DEEP 16 GA. LEG TRACK W/ VERT. SLOTTED HOLES - ATTACH W/ 2-#8 SCREWS @ 24" O.C. DO NOT ATTACH GYP. BD. TO TRACK. ALTERNATE: USE16 GA. SLP-TRK BY METAL LITE, INC. CONFORMING TO CBC STD. NO. 27-9 800S125-43 600S125-43 600S125-33 362S125-33 362S125-18 GYP. BD. O/ METAL STUD FRAMING SEE WALL LEGENDS inches DESIGNATION THICKNESS lb/ft STUD SIZE DESIGN WEIGHT GROSS SECTION PROPERTIES METAL STUD BLOCKING- BEND END OF BLCKG MIN 2" & ATTACH TO STUDS W/ 2-#4 SCREWS EA. END- BLCKG. NOT REQD. W/ SLP-TRK ALT. OR WHEN WALL IS SHEATHED EA. SIDE. NOTES: 0.0451 0.0451 0.0346 0.0346 0.0188 1.62 1.31 1.01 0.73 0.40 0.475 0.385 0.297 0.215 0.118 in^2 AREA 3.721 1.817 1.409 0.421 0.234 in^4 Ix 2.799 2.173 2.179 1.4 1.409 in Rx 0.056 0.053 0.042 0.037 0.021 in^4 Iy 0.342 0.369 0.374 0.413 0.421 in Ry 3.696 1.802 1.391 0.415 0.215 in^4 Ix 0.894 0.584 0.408 0.201 0.09 in^3 Sx 0.475 0.385 0.297 0.215 0.118 in^2 A 17.67 11.55 8.06 3.96 1.78 Office of Architectural Design FACTORY CURB, SEE MECHANICAL DRAWINGS 15231 Alton Parkway, Suite 100 Irvine, CA 92618 24 GA GI FLASHING PAN O/ MODIFIED BITUMEN MEMBRANE O/ FIBERGLASS BASE SHEET O/ 3/4" PLYWOOD BASED ON 5.0 PSF LATERAL LOAD AND L/120 DEFLECTION - SEE STRUCT. CALCS 2010 CBC NOTES: 1. ALTERNATE: USE SUPERIOR #53 20 GA. CLG. DEFLECTION TRACK OR APPROVED EQ. IN PLACE OF 3" TRACK SHOWN & ATTACH STUD TO BOTTOM OF TRACK 2. ALTERNATE: USE SLP-TRK BY METAL LITE, INC. CONFORMING TO UBC STD. 27-9 IN PLACE OF 3" TRACK SHOWN & ATTACH STUD TO BOTTOM OF TRACK 3. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL NOTES. RGA MAXIMUM PARTITION HEIGHT T 949-341-0920 FX 949-341-0922 1 mil= (1/1000) in IN mils THICKNESS 125= 1 1/4" 4" FIBER CANT STRIP 600=6" SHAPED 6x WOOD CURB WITH 3x6 JOISTS @ 16" O.C. MIN. FLANGE WIDTH 800=8" STUD 362=3 5/8" Ma (in-k) STUD DEPTH PROPERTIES MOMENT 362 S 125 - 18 EFFECTIVE SECTION ALLOWABLE CONSULTANT BUR O/ PLYWOOD DECK 1. ALL METAL STUDS USED SHALL BE S125 TYPE OR APPROVED EQUAL. BLOCKING PER STRUCTURAL 2. THIS SCHEDULE SHALL APPLY TO ALL INTERIOR PARTITION WALLS U.N.O. ON THE DRAWINGS. WALLS SHALL HAVE GYPSUM BOARD ON EACH SIDE OR MANUFACTURER'S RECOMMENDED HORIZ. STRAPPING. NOTES: 1. SEE STRUCTURAL DRAWINGS FOR FURTHER INFORMATION. 2. ANY SECURMENT OF UNITS OR SUPPORTS INTO THE HORIZONTAL PLATFORM SURFACE SHALL BE THRU A SOLID 1/4" NEOPRENE GASKET. APPLY ELASTOMERIC SEALANT ON UNDERSIDE AND TOP OF GASKET IMMEDIATELY PRIOR TO INSTALLING BOLTS. 3. INSTALL PLYWOOD OR PERLITE CRICKET ON HIGH SIDE OF CURBS WIDER THAN 96" - MITER PLYWOOD TO MEET FLUSH W/ DECK - RAISE CURB TO MAINTAIN MIN. 7-1/2" CLR. ABOVE TOP OF CRICKET. 3. ALL BRIDGING, BLOCKING OR END BEARING STIFFNERS SHALL BE AS REQUIRED BY THE MANUFACTURER U.N.O. ON THE DRAWINGS. 4. ALL METAL STUDS SHALL CONFORM TO AISI-NAS STANDARDS. 5. TOP TRACK SIZE SHALL BE 33 MIL. MIN. FOR PARTITION U.N.O. 17 FULL HEIGHT WALL @ ROOF TRUSS 13 SCALE: 1-1/2" = 1'-0" 04550 METAL STUD PARTITION SCHEDULE 9 SCALE: N.T.S. ROOF STRUCTURE - SEE STRUCT. DWGS. JOIST SIZE 1" 3-5/8" 218 GA BLOCKING @ 24" O.C. WHERE WALL IS PERPENDICULAR TO ROOF 2 X STRUCT. PROVIDE CLIP ANGLE @ EA. END W/ 2-#8 SCREWS EA. LEG JOIST SPAN JOIST SPACING GYP. BD. O/ METAL STUD FRAMING SEE WALL LEGENDS OVERHEAD DOOR JAMB HARDWARE PER MANUFACTURER NOTES: 1. ALTERNATE: USE SUPERIOR #53 20 GA. CLG. DEFLECTION TRACK OR APPROVED EQ. IN PLACE OF 3" TRACK SHOWN & ATTACH STUD TO BOTTOM OF TRACK 2. ALTERNATE: USE 16 GA. SLP-TRK BY DIETRICH METAL FRAMING PER ICC ES REPORT #1042. 3. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL NOTES. 4. IF DRYWALL IS CALLED FOR ONLY ON ONE SIDE OF STUD ABOVE CEILING JOIST; THEN ADD HORIZONTAL 2" X 22 GA. STRAP 5'-0" O.C. VERTICALLY CONNECTED TO EACH STUD WITH #8 SCREWS IS REQUIRED. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFO. OVERHEAD DOOR HEAD SCALE: 3" = 1'-0" 02335 FULL HEIGHT WALL @ ROOF STRUCTURE 14 SCALE: 3" = 1'-0" 04530 10 1 PROFESSIONAL SEALS 362S125-18 (25 GA) 16" 24" 8'-0" 7'-0" 48" O.C. 362S125-33 (20 GA) 16" 24" 11'-0" 9'-0" 42" O.C. 600S125-33 (20 GA) 2007 CBC 16" 24" 16'-0" 13'-0" 42" O.C. PIPE PENETRATION OR SUPPORT STAINLESS STEEL CLAMP W/ ELASTOMERIC SEALANT 2-1/2# LEAD FLASHING SLEEVE - SET BASE FLANGE INTO ROOF CEMENT O/ INSTALLED INTERPLY FELT - USE 4# LEAD IF FIELD SOLDER IS REQD. 8" MIN WINEVILLE CENTER POINTE SOUTH BUILDING 2 TENANT IMPROVEMENT FOR ROOF CEMENT NOTES: METAL STUD BLOCKING- BEND END OF BLCKG MIN 2" & ATTACH TO STUDS W/ 2-#4 SCREWS EA. END- BLCKG. NOT REQD. W/ SLP-TRK ALT. OR WHEN WALL IS SHEATHED EA. SIDE. NOTES: 1. SEE STRUCTURAL DWGS. FOR ADDITIONAL NOTES. 03311 CEILING TIE SPACING BASED ON 4.0 PSF VERTICAL LOAD AND L/360 DEFLECTION - SEE STRUCT. CALCS. DYWALL WALL 18 MAXIMUM JOIST SPAN SCALE: 3" = 1'-0" 3" DEEP 14 GA. LEG TRACK W/ VERT. SLOTTED HOLES - ATTACH W/ 2-#8 SCREWS @ 24" O.C. DO NOT ATTACH GYP. BD. TO TRACK. ALTERNATE: USE 16 GA. SLP-TRK BY DIETRICH MANUF. 6" MIN PER MANUF. 1" 2" OVERHEAD DOOR - HARDWARE & MOUNTING PER MANUF. - SEE DOOR SCHEDULE FOR ROLL-UP OR VERTICAL LIFT DESIGNATION PROVIDE OVERLAPPING GYP. BD. AT FIRE RATED ASSEMBLIES ONLY U.N.O. SECURE TO 25 GA. BLOCKING 09200 EQUIPMENT PLATFORM 5 2-PLYS AND CAP EMBEDED IN ASPHALT 1. ALL METAL JOISTS USED SHALL BE S125 TYPE, 33 KSI BY CEMCO OR APPROVED EQUAL. 2. WHERE CEILING SUPPORTED TOILET PARTITIONS OCCUR, USE 600S125-43 @ 16" O.C. UP TO 16'-0" MAXIMUM SPAN. B.U.R. O/ PLYWOOD DECK 3. ANY ADDITIONAL EQUIPMENT PLACED ON CEILING JOIST SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT PRIOR TO INSTALLATION. 4. JOIST TRACKS SHALL BE UNPUNCHED AND OF SAME GAGE AS JOISTS U.N.O. 5. IF THERE IS NO SHEATHING ACROSS THE TOP OF JOISTS, USE 362S125-43 CEILING TIES ACROSS TOP OF JOISTS PER SCHEDULE. ATTACH TO EACH JOIST WITH 1 - #8 SCREW. REFER TO DETAIL 3/- FOR JOIST/STUD DESIGNATION METAL CEILING JOIST SCHEDULE 1 SCALE: N.T.S. 09202 UPS SUPPLY CHAIN SOLUTIONS 11811 LANDON DRIVE SUITE 100 MIRA LOMA, CA 91752 NOTES: 1. USE A CONT. LEAD SOLDER IF SPLIT LEAD SLEEVE IS REQD. CLAMPED LEAD PIPE FLASHING 6 SCALE: 1-1/2" = 1'-0" 03201 2 PHASE 3 2" (E) BOTTOM CHORD OF JOIST 9" 1 1/2" 5" WAREHOUSE SIDE 1 1/2" 00 1 1/2" GRIDLINE OPENING PLATE 7" X 1/2" X 1'-0" W/ 2- 3/4" DIA. M.B. W/ WASHERS AS REQ. 1/4 H.S.S. BASE PLATE 6" X 1/2" X 1'- 1" W/ 2- 3/4" DIA. EPOXY BOLTS USE HILTI HIT-RE 500-SD (ESR-2322) H.S.S. GRIDLINE 00 3" 1/4 GYP BD OVER METAL STUDS AS NOTED ON ON FLOOR PLAN. PROVIDE INSULATION WHEN NOTED ON FLOOR PLAN. ATTACH STUDS TO TRACK WITH #8 SCREWS THROUGH FLANGE CONT. METAL TRACK RUNNER. ATTACH TO FLOOR WITH 0.180" POWER DRIVEN SHOT PINS @ 16" O.C. MAX. AT CONCRETE FLOOR SLAB. (ESR-1799) W/ MIN. 1-1/2" EMBEDMENT. LEAD SLEEVE WITH FLANGE SET IN CEMENT FLASHING PITCH BASE MOULDING 2-PLYS AND CAP EMBEDED IN ASPHALT FINISH FLOOR BASE PLATE PLAN VIEW B SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" HEALTHCARE SIDE A GYP. BD. O/ METAL STUDS SEE WALL LEGENDS 1 - LAYERS OF 5/8" GYP. BOARD O/ 8" METAL STUDS. SEE FLOOR PLAN FOR ASSEMBLY DOOR PER NOTES HEAD DETAIL GYP. BD. O/ METAL STUDS SEE WALL LEGENDS 1 PARTITION @ FLOOR SCALE: 3" = 1'-0" 04000 SCALE: 1-1/2" = 1'-0" T A - A - SEE FLOOR PLAN NOTE FOR HEIGHT 38" T 6" SEE NOTES 03200 30% REVIEW SET 5/9/12 80% REVIEW SET 6/5/12 ADDENDUM 1 3 TYP. 1/4L H.S.S. SEE STRUCTURAL DWG'S. - H.S.S. SEE STRUCTURAL DWG'S. METAL DOOR FRAME PER SCHEDULE - ATTACH PER MANUF. SPECS. PENETRATIONS THROUGH FIRE RATED WALL ASSEMBLIES SHALL BE PROTECED BY AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH UBC STANDARD 7-5 AND SHALL HAVE AN F RATING OF NOT LESS THAN THE REQUIRED RATING OF THE WALL PENETRATED. CD BID UNIT CURB OR PLATFORM CANT STRIP RATED FLOOR/ CEILING ASSEMBLY - 2X8 CURB FIBER CANT STRIP W/ 3'' LEGS NAIL TO CURB AT 12'' O.C. RATED WALL ASSEMBLY BID SET 5/24/12 PLAN CHECK DD 4/5/12 DESIGN DEVELOPMENT SD 3/13/12 SCHEMATIC DESIGN MARK DATE DESCRIPTION RGA PROJECT NO: 11189-00 OWNER PROJECT NO: 00000.00 CAD FILE NAME: 11189-00-AD-2 DRAWN BY: MG CHK'D BY: DR COPYRIGHT RGA, OFFICE OF ARCHITECTURAL DESIGN REFER TO TYPICAL ROOF SECTION PENETRATION SEE FLOOR PLAN FOR OPENING CONSTRUCTION SET PC SILL NOTES: 1. SEE SHEET A5.1 FOR ADDITIONAL DOOR NOTES. 1 PLAN VIEW CRICKET PENETRATIONS THROUGH FIRE RATED FLOOR/CEILING ASSEMBLIES SHALL BE PROTECED BY AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH UBC STANDARD 7-5. THE SYSTEM SHALL HAVE AN F RATING AND A T RATING OF NOT LESS THAN ONE HOUR, BUT NOT LESS THAN THE REQUIRED RATING OF THE FLOOR PENETRATED. SILL DETAIL SHEET TITLE DETAILS NOTES: 1. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION CONCERNING CONNECTION. 2. SEE STRUCTURAL DRAWINGS F0R CONNECTION AT STEEL BEAM 3. SEE STRUCTURAL DRAWINGS FOR CONNECTION AT BAR JOIST. TYPICAL DOOR NOTES & INTERIOR DETAILS SCALE: 1-1/2" = 1'-0" VENT PIPE & FLASHING 7 L JAMB PROVIDE THRESHOLD OR CARPET BAR WHERE REQD. AND AT CHANGE OF FLR. MAT. - CHANGE OF MAT. TO OCCUR AT C.L. OF DOOR. BEVEL TOP 1/4" AT MAX 1:2 11 - JAMB DETAIL DOOR PER NOTES - UNDERCUT DOORS 3/4" EXCEPT @ FIRE RATED COND. COLUMN FURRING @ 1 HR. WALL 4/5/12 H.S.S. SEE STRUCTURAL DWG'S. HEAD DOOR PER NOTES B - 3/16 SHEET METAL COLLAR O/ ROOFING HOT MOP VENT PIPE SCALE: 3" = 1'-0" FULL HT. SIDELIGHT WHERE INDICATED ON PLANS TEMPERED SAFETY GLAZING METAL DOOR FRAME & HINGES PER SCHEDULE ATTACH PER MANUF. SPECS 1/2" MAX: BEVEL TOP 1/4" AT MAX 1:2 B - DOOR GLAZING WHERE INDICATED ON PLANS TEMPERED SAFETY GLAZING 12380 MORRIS ROAD ALPHARETTA, GA 30005 678-746-4006 NOTES: 1. SEE FLOOR PLANS FOR LOCATION OF INSULATION AND FIRE RATINGS. 2. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL FRAMING NOTES. DRYWALL SCREWS. VERIFY THICKNESS FOR PROPER LENGTH EXISTING STRUCTURE ABOVE SEE STRUCTURAL DRAWINGS. UPS SUPPLY CHAIN SOLUTIONS SEALANT EXISTING STRUCTURAL COLUMN. CONTRACTOR TO VERIFY SIZE METAL DOOR FRAME PER SCHEDULE - ATTACH PER MANUF. SPECS. 6" BUILT-UP ROOFING O/ PLYWOOD DECK 6" BEAM CONNECTION 4" 04201 20 TYP. DOOR OPENING SUPPORT @ GIRDER COND. SCALE: 1 1/2" = 1'-0" 09102 1/2:12 TAPERED PERLITE CRICKET NOTES: 1. REFER TO APPLICABLE FLASHING DETAIL FOR APPROPRIATE ROOFING AND FLASHING COMPONENTS (NOT SHOWN). 2. TOE OF CANT TO TOE OF CANT. 3. MINIMUM 2'' AT "RIDGE" 4. MINIMUM 1/2:12 SLOPE 16 PROTECTION OF PENETRATIONS SCALE: N.T.S. 04600 12 8 TYPICAL CRICKET NTS OPTION 2 PLAN 4 SHEET: AD-2 DUCT CONSTRUCTION NOTES 1. CONSTRUCTION OF DUCTWORK SHALL MEET SMACNA 2" W.C. PRESSURE CLASS STANDARD AND RECOMMENDATIONS. SMACNA SHALL BE FOLLOWED WITH RESPECT TO GAGE THICKNESS, JOINTS, REINFORCING, CONSTRUCTION, INSTALLATION AND SUPPORT FOR PRESSURE CLASS STATED. ALL TRANSVERSE JOINTS IN RECTANGULAR AND ROUND DUCT SHALL BE SEALED PER SMACNA SEAL CLASS C WITH UL DUCT MASTIC SEALANT APPROVED FOR INTENDED USE. DUCT TAPE IS NOT AN ACCEPTABLE SUBSTITUTE FOR MASTIC. 2. ALL DUCT TO BE SHEET METAL, U.N.O. 3. RECTANGULAR DUCT SHALL BE FABRICATED USING TDF/TDC STYLE JOINING METHOD AS DESCREED IN SMACNA DUCT CONSTRUCTION STANDARDS, LATEST EDITION FOR T25A OR T25B JOINTS. 4. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS, U.N.O. 5. ALL DUCT INSULATION SHALL MEET MINUMUM R‐VALUE REQUIRED BY ASHRAE 90.1 LATEST EDITION. ALL DUCT WRAP SHALL BE MINIMUM 2" THICK, 3/4 PCF AND 5.6 R‐VALUE INSTALLED WITH EITHER A VAPOR BARRIER WITH MAXIMUM PERMEANCE 0.05 OR A MINIMUM 2 MIL. ALUMINUM REINFORCED FOIL/DRAFT FACING. INTERNAL DUCT LINER SHALL BE MINIMUM 1.5" THICK AND 1.5 PEF 6.0 R‐VALUE INSTALLED WITH ANTI‐MICROBIAL GROWTH AGENT AND ENCAPSULANT EDGE COATING. ACCEPTABLE MANUFACTURERS OF INSULATION ARE MANVILLE, OWENS CORNING OR KNAUF. 6. DUCT TAPE SHALL BE EQUAL TO FASSON 181‐B FX, 2‐1/2" WIDE. 7. EXTERNAL INSULATION ON BOTTOM OF DUCTS 24" OR WIDER SHALL BE SECURED TO DUCT WITH STICK PINS AS DESCRIBED IN SMACNA DUCT CONSTRUCTION STANDARDS LATEST EDITION. STICK PIN WASHERS SHALL BE COVERED WITH DUCT TAPE OR MASTIC. 8. TRUNK DUCTS SHALL BE ISOLATED FROM ANI HANDLING UNIT VIBRATION WITH THE USE OF NFPA AND UL APPROVE FLEXIBLE CONNECTORS INSTALLED AT THE UNIT CONNECTIONS. 9. SQUARE ELBOW FITTINGS MAY BE SUBSTITUTE FOR RADIUSED FITTINGS AT THE DISCRETION OF THE MC. SQUARE ELBOWS TO HAVE TURNING VANES AS DESCRIBED HEREIN. 10. SINGLE THICKNESS TURNING VANES SHALL BE INSTALLED AT 90 DEGREE TURNS IN RECTANGULAR SUPPLY DUCTWORK WHERE ANY ONE DIMENSION IS GREATER THAN 12". 11. RADIUSED ELBOWS SHALL HAVE A CENTERLINE RADIUS (R ) EQUAL TO WIDTH (R‐W). 12. SLOPE ON DUCT TRANSITIONS TO FOLLOW SMACNA HVAC DUCT CONSTRUCTION STANDARD, LATEST EDITION. DUCT SUPPORT NOTES: 1. THE INTENT OF THIS DETAIL TO GIVE THE MC AN ALTERNATIVE TO SUPPORTING THE DUCTWORK AT EACH BAR JOIST POTENTIALLY REDUCING MATERIALS REQUIRED. THE MC IS NOT REQUIRED TO BRIDGE THE JOISTS AS SHOWN HERE AND IS FREE TO SUPPORT THE DUCT AT EACH BAR JOIST AS LONG AS THE SPACING INTERVALS IN THE CUT SUPPORT SCHEDULE ARE SATISFIED. 2. SEE INSET "B" FOR ATR ATTACHMENTS TO TOP CHORD OF BAR JOIST. THIS IS APPLIES WHERE THE MC PREFERS TO SUPPORT THE DUCT AT EACH JOIST OR WHERE THE DUCT SUPPORT INTERVAL FALLS AT A JOIST THEREFORE NOT REQUIRING BRIDGING. 3. SEE DUCT SUPPORT SCHEDULE ON THIS SHEET FOR SUPPORT OF DUCT. 4. ANY ATTACHMENTS TO THE BAR JOISTS MUST BE MADE FROM THE TOP CHORD. 5. DO NOT LOCATE ATR IN FRON OF DRUM LOUVERS.