ISOVER Pitched Roof Solutions
Transcription
ISOVER Pitched Roof Solutions
Want to know more? See our Metac video ISOVER Pitched Roof Solutions Insulation, Airtightness and Moisture Management Solutions for Timber Frame Roof Structures PART L | TGD F1 Compliant ISOVER Saint Gobain helping you create energy efficient buildings that provide a comfortable, healthy indoor environment using sustainable solutions. Pitched Roof Solutions Pitched Roof Solutions e anc nt form r e me at P o Use nviron e r G T ur E tle Gen For O ON N d ATI ATIO Goo Pitched Roof Application ISOVER Metac and Vario System 1 ERINSUL L EN GW OO W NIENERAL M ISOVER offers one of the safest options for insulating Pitched Roofs both in New Build and Renovation. Metac is a high performance mineral wool insulation ‘slab on a roll’ which when used with our Vario Airtightness and Moisture Control System offers one of the safest, and thermal and acoustic performing systems on the market. W/mK 0.034 ✔✔ High Performance thermal insulation 0.034W/mK ✔✔ Excellent Acoustic Performance ✔✔ A1 Fire rating – highest rating on the market BS EN 13501-1 ✔✔ No slump during installation and life of the system ✔✔ Friction fits in rafters eliminating any air gaps ✔✔ Vario XtraSafe membrane ‘apply and release function’ for quick installation ✔✔ Vapour permeable insulation for maximum protection from moisture and condensation issues ✔✔ Metac Insulation can be full filled when used with our Vario system* ✔✔ Excellent Indoor Air Quality – Eurofins Gold Comfort ✔✔ Made from Recycled materials – up to 86% recycled glass ✔✔ G3 Touch technology, great performance, gentle to use, good for the environment *Please ensure installation is in accordance with roof slate/tile and roof membrane manufacturers guidelines. BS EN ISO 9001: 2000 EN ISO 13162 WHERE TO USE EMS 551706 003 10+ YEARS Residential Non Residential New and Old www.isover.ie NEW BUIL D U VALU ES: 2 0.16 PITCH ED R O O F RENOVAT ION U VA LUES: 0.25 PITCH ED R O O F Pitched Roof Solutions Building Regulations Republic of Ireland The following is a guide to thermal building regulations for new & existing dwellings - comfort and energy savings through effective thermal insulation. Republic of Ireland New Dwellings TGD - Part L - 2011 0.21 (walls) 0.16 (attics) 0.16 (pitched roof ) 0.20 (fl at roofs) Minimum standards for U-Values Upper limit for air permeability is 7m3/(h.m2) Average U-Value 1.60 (doors and window s) 0.21 (walls ) 0.21 (floors) 0.21(walls ) 0.21 (floors) For more information you can contact our technical team on free phone (ROI) 1800 744480 or go to www.isover.ie Republic of Ireland Existing Dwellings TGD - Part L - 2011 Minimum standards for U-Values 0. 35 (walls ) 0.16 (attics) 0.25 (pitched roof ) 0.25 (flat roofs) Average U-Value 1.60 (doors and window s) 0. 35/0.55 (walls ) 0.25 (floors) 0. 35 (walls ) 0. 45 (floor s) For more information you can contact our technical team on free phone (ROI) 1800 744480 or go to www.isover.ie www.isover.ie 3 NEW BUIL D U VALU ES: 0.20 PITCH ED R O O F RENOVAT ION U VA LUES: 0.18 PITCH ED R O O F Building Regulations Northern Ireland The following is a guide to thermal building regulations for new & existing dwellings - comfort and energy savings through effective thermal insulation. Northern Ireland 0.30 (Walls – Internal/External Insulation) 0.20 (Roofs – Attics) 0.20 (Roofs – Flat) 0.20 (Roofs – Pitched) New Dwellings– DFP Technical Booklet F1:2012 Average 2.00 (Doors & Windows) Minimum standards for U-Values Upper limit for air permeability is 10m3/(h.m2) 0.30 (Walls – Cavity insulation) 0.30 (Walls – Internal/ External insulation) 0.20 (Party Walls) 0.25 (Floors) 0.30 (Walls – Cavity insulation) 0.30 (Walls – Internal/External insulation) 0.25 (Floors) For more information you can contact our technical team on phone (NI) 0845 339 0159 or go to www.isover.ie Northern Ireland Existing Dwellings - DFP Technical Booklet F1:2012 Minimum standards for U-Values These regulations are split across new thermal elements added to an existing dwelling, for example a new extension or dormer & upgraded thermal elements within the existing building. 0.28*/ 0.30 (Walls – Internal/External Insulation) 0.16*/ 0.16 (Roofs – Attics) 0.18*/ 0.18 (Roofs – Flat) 0.18*/ 0.18 (Roofs – Pitched) Average 2.00 (Doors & Windows) 0.28*/ 0.55 (Walls – Cavity insulation) 0.28*/ 0.30 (Walls – Internal/ External insulation) 0.22*/ 0.25 (Floors) 0.28*/ 0.55 (Walls – Cavity insulation) 0.28*/ 0.30 (Walls – Internal/External insulation) 0.22*/ 0.25 (Floors) *figures refer to a new element added to an existing dwelling i.e. extension, dormer etc. For more information you can contact our technical team on phone (NI) 0845 339 0159 or go to www.isover.ie Pitched Roof Solutions Pitched Roof Solutions 4 Standards and Certification A SELF-SUPPORTING SLAB ON A ROLL – IDEAL FOR VERTICAL AND PITCHED APPLICATIONS NO SLUMP DURING INSTALLATION AND LIFE OF THE SYSTEM ✔✔ QUALITY BREATHABILITY-VARIO MEMBRANE FOR MAXIMUM PROTECTION FROM MOISTURE We hold a Quality Management Standard BS EN ISO 9001: 2008 for manufacturing. ✔✔ CE All products are manufactured in accordance with the CE marking requirements under the Construction Products Regulation. BS EN ISO 9001: 2000 ✔✔ PRODUCT STANDARDS All our products are manufactured in accordance with product standard: BS EN 13162: 2008 and BS EN 13172 Evaluation of Conformity. ✔✔ ENVIRONMENT ISOVER is an ISO 14001:2004 (Environmental Management System) accredited manufacturing facility. This accreditation ensures that all products are manufactured to the stringent standards set out by this management system. EN ISO 13162 EMS 551706 003 BS EN ISO 9001: 2000. EN ISO 13162 ✔✔ INDOOR AIR QUALITY Awarded the highest standard in indoor air quality - Eurofins “Gold” Label The Gold Certificate means that ISOVER mineral wool is certified as an outstanding material in terms of Indoor Air Quality emissions regulations. ✔✔ DURABILITY Fire Performance Euroclass classification of the product is related to the organic content, which cannot increase with time. Thermal conductivity of mineral wool products does not change with time, experience has shown the fibre structure to be stable and the porosity contains no other gases than atmospheric air. (See std EN13162:2012 Annex ZA,Table ZA.1) Will not accelerate corrosion with steel, copper or aluminium. Will not sustain vermin, nor breed or promote fungi or bacteria. www.isover.ie EMS 551706 003 The standards cove r: 5 ✔✔ Dealing with high moisture levels and condensatio n to protecting the building fabric. Control of Condensation and Ventilation ISOVER complies with BS 5250:2011 Code of practice for control of condensation in buildings & ICP 2:2002 Irish Standard for Tiled and Slated Roof Constructions. These are the industry standards to ensure the building fabric is protected from moisture and condensation damage by ensuring adequate vapour control and ventilation measures are installed. ✔✔ Addressing the ris ks associated with excessive humidit y in buildings, notably mould gro wth and condensation. ✔✔ Ensuring a sufficie ntly permeable roof build up i.e. use of an adequate breathable roofin g felt in conjuncti on with an air-open roof covering (e.g . natural slates or concrete tiles not fibre cement). ✔✔ Recommending Be st Practice construction, cou nter-battens above the roof membran e allows for better drainage rai n water and can accommodate ven tilation under non-air open cov erings where ridge and eaves vents are provided over the felt. ISOVER Pitched Roof Solutions - How do they comply with these indust ry standards? • Protecting Building Fab ric Managing moisture vapour • Healthy Indoor Air Qu ality - dealing with mould growth and condensation • Energy Savings - Creati ng an airtight construction • Full ISOVER Solution: High performance mineral wo ol insulation + airtightness, moisture control. Good practice details: 1 ✔✔ Concrete tiles or natural slates (air-open) ✔✔ Slating laths ✔✔ Counter battens (for roof drainage) 1 ✔✔ LR (breathable) roofing felt ✔✔ Full fill ISOVER Metac insulation ✔✔ Vario KM Duplex or XtraSafe Intelligent Airtightness VCL ✔✔ Composite PIR thermal laminate by others* 2 ✔✔ Fibre cement slates (air-closed) ✔✔ Slating laths 2 ✔✔ Counter battens (provides ventilation space) ✔✔ LR (breathable) roofing felt ✔✔ Full fill ISOVER Metac insulation ✔✔ Vario KM Duplex or XtraSafe Intelligent airtightness VCL ✔✔ Composite PIR thermal laminate by others* 3 3 ✔✔ Concrete tiles or natural slates (air-open) ✔✔ Slating laths ✔✔ LR (breathable) roofing felt ✔✔ Full fill ISOVER Metac insulation ✔✔ Vario KM Duplex or XtraSafe Intelligent airtightness VCL 4 ✔✔ Composite PIR thermal laminate by others* 4 ✔✔ Concrete tiles or natural slates (air-open) ✔✔ Slating laths ✔✔ LR (breathable) roofing felt ✔✔ Full fill ISOVER Metac insulation ✔✔ Vario KM Duplex or XtraSafe Intelligent airtightness VCL ✔✔ Composite PIR thermal laminate by others* *Maximum R-value = 1/3 of total Roof insulation. Pitched Roof Solutions Pitched Roof Solutions 6 If renovating or converting your attic, Metac easily exceeds renovation regulations! Pitched Roofs Pitched Roof insulation full filled between rafters + Vario 1 Tiled or slated roof with external counter battens/ ventilation space* 1 2 ISOVER breathable felt Ecran 3 ISOVER insulation installed between rafters 4 Vario membrane + tapes 3 2 5 12.5mm Gyproc WallBoard *Even in instances where there is no external counter batten/ventilation space Metac can still be full filled once used with XtraSafe. Contact our Technical department for more information. 4 5 Airtightness/Moisture Control Board lining U-value W/m2K Metac 180 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.22 Metac 220 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.16 Metac 300 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.13 ISOVER PRODUCTS Insulation in rafters mm www.isover.ie + Metac Roll Vario System 7 Pitched Roof with Internal Counter Batten Insulation full filled between rafters + Vario + internal counter battens 1 Tiled or slated roof with external counter battens/ ventilation space* 2 ISOVER breathable felt Ecran 3 ISOVER insulation installed between rafters 4 Vario membrane + tapes 1 2 5 ISOVER insulation between counter battens 6 3 4 Gyproc WallBoard *Even in instances where there is a non permeable roof finish (fibre cement slates) and no external counter batten/ventilation space Metac can still be full filled once used with XtraSafe. Contact our Technical department for more information. 5 6 Insulation in counter batten Airtightness/Moisture Control Board lining U-value W/m2K Metac 150 Metac 50 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.18 Metac 180 Metac 50 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.16 Metac 220 Metac 50 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.14 ISOVER PRODUCTS Insulation in rafters mm + Metac Roll Vario System Pitched Roof Solutions Pitched Roof Solutions 8 Pitched Roof with Calibel Insulation full filled between rafters + Vario + Calibel ISOVER’s Roof Solution is the best possible option to protect timber roof structures, Metac insulation can be fully filled in rafters even in non breathable roof structures – the Safer option! When used with Calibel laminate it offers a fully breathable solution with moisture protection for the building fabric! 1 Tiled or slated roof on tiling battens 2 ISOVER breathable felt Ecran 3 ISOVER insulation installed between rafters 4 Vario XtraSafe membrane and tapes 5 ISOVER Calibel 1 2 4 3 5 Airtightness & moisture control layer Thermal laminate U-value W/m2K Metac 150 Vario XtraSafe 42.5 Calibel 0.20 Metac 150 Vario XtraSafe 62.5 Calibel 0.18 Metac 180 Vario XtraSafe 62.5 Calibel 0.16 Metac 220 Vario XtraSafe 62.5 Calibel 0.14 ISOVER PRODUCTS Insulation in rafters mm www.isover.ie + Metac Roll + Calibel Board Vario System 9 Pitched Roof with Thermal Laminate Insulation full filled between rafters + Vario + Thermal Laminate ISOVER Metac can be full filled between rafters with Vario KM Duplex and a thermal laminate, where there are air-open tiles/slates with no counter battens/ventilation space on outside roof structure. 1 Air-open tiles/slates on tiling battens (no ventilation space/ counter-battens) 2 ISOVER breathable roof membrane 3 ISOVER insulation installed between rafters 4 Vario KM Duplex membrane and tapes 5 1 2 3 Thermal Laminate 4 5 If installing in a closed roof construction i.e. Fibre Cement roof tiles with no counter battens on exterior, a 50mm ventilation space must be left between insulation and roof membrane. Insulation in rafters mm Airtight layer only Thermal laminate U-value W/m2K Metac 150 Vario KM Duplex 32.5mm Thermal laminate 0.20 Metac 150 Vario KM Duplex 42.5mm Thermal laminate 0.18 Metac 150 Vario KM Duplex 62.5mm Thermal laminate 0.15 Metac 180 Vario KM Duplex 72.5mm Thermal laminate 0.13 Metac 220 Vario KM Duplex 72.5 Thermal laminate 0.11 ISOVER PRODUCTS * Refers to a rigid foam insulation material and a 12.5mm plasterboard, please refer to manufacturers guidelines for performance. + Metac Roll Vario System Pitched Roof Solutions Pitched Roof Solutions Installation Pitched Roof ✔✔ Measure depth and width of rafters. Then measure the length and width of the building and multiply twice the span of the rafters by the length of the building. ✔✔ Lift Metac into the attic still in its packaging. ✔✔ Measure and cut the roll to fit rafter width leaving 10mm extra on dimension. ✔✔ Unroll and allow full recovery, use a straight edge and sharp insulation knife. ✔✔ Push and friction fit between rafters, keeping flush with rafters. Ensure eaves ventilation is left where required. ✔✔ Metac can be fully filled* between rafters when used with our Vario XtraSafe membrane installed below the insulation with Gyproc Plasterboard to complete the installation - this provides the safest solution to protect timber rafters from moisture damage. ✔✔ To increase the u Value Isover recommends installing 50 x 50mm counter battens filled with 50mm Metac – this allows a service zone without need to pierce airtight membrane. ✔✔ Finally use Gyproc plasterboard applied to counter battens to complete the installation. WANT TO KNOW MORE? www.isover.ie 10 Technical Academy 11 Technical Training Looking for Technical Advice? Need Training on ISOVER Systems? Practical hands on training & theory courses ISOVER Multi Comfort House; A guide to passive house building in Ireland. I nsulation, an overview; theory & practical. A guide to ISOVER insulation systems and on-site practices. A irtightness and moisture management; theory, systems & on-site solutions. Technical advice provided on: Low energy / passive house building. U-Value calculations. Condensation risk analysis. Thermal bridge support and advice. On-site support and detailing. Dry lining & moisture management; theory, systems & on-site solutions. R oof insulation; theory, systems & on-site solutions. Call our Technical Team on 1800 744 480 today Email [email protected] Pitched Technical Roof Solutions Training Pitched Roof Solutions 12 high performance rafter insulation ISOVER Metac Roll A high performance quality thermal insulation roll designed for a wide range of applications where space is at a premium. PRODUCT FEATURES ✔✔ Thermal Conductivity 0.034 W/mK ✔✔ Excellent Acoustic Performance ✔✔ Excellent Fire Safety - A1 Fire Rated ✔✔ Vapour permeable breathable insulation ✔✔ Improves energy performance and reduces heating & cooling costs ✔✔ Easy to install. Friction fits between timber stud, joists and rafters with no need for additional fixings ✔✔ Made from recycled glass. Minimal manufacturing and on-site wastage. Low carbon footprint at manufacture and during transport W/mK 0.034 Thickness (mm) Width (mm) Length (mm) Pack Area (m2) Pack Per Pallet Metac G3 Touch 50 1200 12000 14.40 12 Metac G3 Touch 100 1200 7000 8.40 12 Metac G3 Touch 150 1200 4800 5.76 12 Metac G3 Touch 150 3 x 400 4800 5.76 12 Metac G3 Touch 180 1200 4000 4.80 12 Metac G3 Touch 180 3 x 400 4000 4.80 12 Metac G3 Touch 220 1200 3300 3.96 12 WHERE TO USE Product www.isover.ie Pitched Roof - Rafters Walls - Internally insulated 13 high performance airtightness & moisture control ISOVER Vario System A high performance system consisting of intelligent membranes and accessory products, providing excellent levels of airtightness with unparalleled protection against moisture. PRODUCT FEATURES ✔✔ High performance airtightness and moisture control system ✔✔ Two intelligent membranes to suit a variety of applications ✔✔ Range of accessory products - high performance tapes and sealants ✔✔ Xtra system with easy installation ‘apply and release function’ no staples required. Product Width (mm) Length (mm) Packaging 1500 40000 60 m2/ roll ISOVER Vario KB1 – Single sided tape 60 40000 5 rolls = 200 m ISOVER Vario DoubleFit Mastic n/a 310ml 12 cartridges ISOVER Vario MultiTape SL 60 25000 10 rolls = 250 m ISOVER Vario Protape 25 10000 5 rolls = 50 m Ecran Integra Roof membrane 1500 50000 75m2/roll ISOVER Vario Xtra Safe Membrane 1.5m 40000 60 m2/ roll ISOVER Vario Xtra Fix Strip 10mm 25000 20 rolls per pack WHERE TO USE ISOVER Vario KM Duplex Membrane Airtightness Pitched Roof Solutions www.isover.ie ISOVER Ireland Unit 4, Kilcarbery Business Park, Nangor Road, Dublin 22 Tel: +353 (0)1 6298400 Email: [email protected] ISOVER Technical Team ROI Free Phone: 1800 744 480 NI Phone: 0845 399 0159 [email protected]