Medical Vacuum Systems: Lubricated Vane
Transcription
Medical Vacuum Systems: Lubricated Vane
Product Specification Medical Vacuum Systems: Lubricated Vane GENERAL The Chemetron® medical vacuum system is designed to create a suction system to remove unwanted fluids or gases from hospital/laboratory working areas. The medical vacuum system package is compliant with the NFPA 99 requirements for medical vacuum. Note that larger systems are shipped on 2 or more skids and require connection of clearly labeled wiring and piping between skids once they are mounted on-site. MEDICAL VACUUM SYSTEM The package shall include multiple vacuum pumps and associated equipment, one ASME tank and one medical control panel. Each pump is factory piped to a common intake manifold. The system shall be completely tested prior to shipment. Vibration isolation pads are included with the system. ROTARY VANE VACUUM PUMP The medical vacuum pumps shall be of the rotary vane air cooled design, and manufactured in the USA. Each vacuum pump shall be direct-driven through a shaft coupling by a TEFC electric motor. Belt drives shall not be permitted. Each vacuum pump shall be air cooled and have absolutely no water requirements. Each vacuum pump shall have an end (ultimate) vacuum of 29.3" Hg (15 torr). Lubrication shall be provided by an integral, fully recirculating oil supply that is filtered by an automotive-type, spin-on oil filter. Non-recirculating (once-through) or partial recirculating oil supply systems shall not be permitted. Each vacuum pump shall be capable of operation with standard SAE 30 weight oil. The oil separation systems shall be integral and shall consist of no less than three stages of internally installed oil and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, oil mist elimination, and smoke elimination, and shall be capable of removing 99.9+ percent of all oil and smoke particles from the exhaust gas stream. Each vacuum pump shall include a built-in anti-suck-back valve, mounted at the pump inlet, and three sliding vanes. Each vacuum pump shall be equipped with a 10 micron inlet filter for removal of particulates. The vacuum pumps shall be mounted on vibration isolators. MOTOR The motor is continuous duty, NEMA rated, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. AIR RECEIVER The system shall include an ASME rated air receiver rated for 200 psi MAWP. The tank shall be equipped with a vacuum gauge, block and by-pass valves, and a manual drain. CONTROL PANEL The system shall include a UL listed control panel in a NEMA 12 enclosure with the following accessories for each pump: externally operable disconnect, magnetic starter with 3-leg overload protection, Hand/Off/Auto lighted selector switch, minimum run timer to prevent short cycling of the pump, and hour meter. Standard features shall also include a main power on light, timed lead/lag pump alternation, a reserve pump-inuse alarm with visual and audible indications, and duplex control circuit transformers with fused primary and secondary protection. All alarms shall have dry contacts on a labeled terminal strip for remote alarm monitoring, and an acknowledge pushbutton for horn silencing. The lag vacuum pump shall be able to start automatically if the lead vacuum pump fails to operate. AVAILABLE OPTIONS High discharge air temperature shutdown alarm with visual and audible indicators and dry contacts Oil temperature gauges Internal tank lining for corrosion resistance Tank sight gauge Product Specification Medical Vacuum Systems: Lubricated Vane Duplex Lubricated Vane Tankmount 1 - 10 hp Duplex Lub ricated Vane MODEL HP1 DLV010-80T DLV015-80T DLV020-80T DLV030-80T DLV050-120T1 DLV050-120T2 DLV075-200T DLV100-200T 1 1-1/2 2 3 5 5 7-1/2 10 No te s : SCFM @ 19" Hg Each 4 7 11 17 26 38 52 77 NFPA System Capacity 4 7 11 17 26 38 52 77 TANK SIZE BTU/HR2 dB(A)3 LEVEL 80 80 80 80 120 120 200 200 2,546 3,819 5,092 7,638 12,730 12,730 19,095 25,460 70 70 70 70 71 71 79 81 SYSTEM F.L.A. 208V 10 11 14 19 30 35 44 55 230V 10 11 14 18 28 32 43 53 1 - HP a nd NF P A S ys te m C a pa c ity is s ho wn with o ne o r m o re pum ps in re s e rve pe r NF P A 99 2 - B TU/HR Le ve ls a re s ho wn with re s e rve pum p(s ) o n s ta ndby 3 - dB (A) is s ho wn with o ne pum p in re s e rve pe r NF P A99 460V 6 7 8 10 15 16 23 28 SYSTEM WEIGHT 730 730 835 894 1,049 1,077 1,727 2,165 Product Specification Medical Vacuum Systems: Lubricated Vane Duplex Lubricated Vane Vertical 1 - 3 hp Product Specification Medical Vacuum Systems: Lubricated Vane Duplex Lubricated Vane Vertical 5 hp Product Specification Medical Vacuum Systems: Lubricated Vane Duplex Lubricated Vane Basemount 7-1/2 - 25 hp Product Specification Medical Vacuum Systems: Lubricated Vane Triplex Lubricated Vane Basemount 5 - 10 hp Product Specification Medical Vacuum Systems: Lubricated Vane Triplex Lubricated Vane Basemount 15 - 25 hp Product Specification Medical Vacuum Systems: Lubricated Vane Quad Lubricated Vane Basemount 5 - 25 hp All specifications are nominal and subject to change without notice. Warranty: See Allied Statement of Warranties for details. © 2009 Allied Healthcare Products, Inc.® Construction Customer Service USA: 800/444-3960 FAX: 314/771-7537 Canada/Mexico: 800/446-0552 FAX: 800/246-6201 International: 314/268-1683 FAX: 314/771-5183 1720 Sublette Avenue St. Louis, MO 63110 USA 314/771-2400 800/444-3954 www.alliedhpi.com ISO 13485: 2003 Product Specification Medical Vacuum Systems: Lubricated Vane Form 62-00-3800 June 2009