Hygolet S3000 Instructional Manual
Transcription
Hygolet S3000 Instructional Manual
Instruction Manual Hygolet Toilet Seat Ring S3000 Introduction Congratulations on your purchase of a Hygolet Toilet Seat Ring S3000. Users will appreciate that you have helped to make their restroom experience significantly more enjoyable. Please read this instruction manual carefully to fully understand the operation of our seat. To ensure trouble-free operation and to enable us to fulfil our warranty commitment, we strictly recommend that you use original hygolet® and hygoplast® spare parts and consumables. Table of contents Page Explosion drawing 2 Seat ring installation 3 Initial start-up 4 Changing Hygoplast roll 6 Changing Hygolet Power Pack 8 Changing blade 10 Cleaning 13 Troubleshooting 14 1 2 Toilet Seat Ring S3000: Seat installation Installation procedure for a Hygolet seat ring is similar to that for an ordinary toilet seat ring Remove old seat ring and clean toilet bowl rim. Insert plastic screw head through slits in fixing-plate of the installation bracket and turn screw by 90°. Insert plastic screw into the toilet-bowl holes. Hand tighten the plastic nuts. The seat ring should be in line with the bowl. Align the seat ring by moving the installation-bracket into the appropriate position. Then tighten the plastic nuts. 3 Toilet Seat Ring S3000: Initial start-up Open lock. Open housing cover. Power pack insertion: Remove protective cover from contacts. Insert power pack until it fits tightly in housing. 4 Toilet Seat Ring S3000: Initial start-up Press Reset. LED-display: 10 bars corresponds to 125 usages. If there is only 1 bar left on the display, less than 10 usages will be left and Hygoplast roll has to be changed soon. Close housing cover. By activating the non-touch sensor on the housing cover, the transport of Hygoplast will be started. 5 Toilet Seat Ring S3000: Changing Hygoplast roll Open lock Open housing cover Remove and dispose of used Hygoplast roll. Place the empty spool on right side. In case clean Hygoplast roll is not finished, repeat activating the non-touch sensor until the roll is empty. Slip new Hygoplast roll over left end of seat ring. Pull roll sticker over the seat ring. 6 Toilet Seat Ring S3000: Changing Hygoplast roll Fit roll sticker completely into slit in empty roll core. Press Reset. Close housing cover. Your Hygolet seat ring is ready for operation. On the LED-display 10 bars will be visible, indicating 125 usages. 7 Toilet Seat Ring S3000: Changing Hygolet Power Pack LED-display is flashing: Power pack has to be changed. Open lock. Open housing cover. Remove and dispose of used power pack. 8 Toilet Seat Ring S3000: Changing Hygolet Power Pack Insert new power pack until it fits tightly in housing. Close housing cover. 9 Toilet Seat Ring S3000: Changing blade Open lock. Open housing cover. Push back and release clip holding seat ring down. Hygoplast can remain on seat ring. Move seat ring in up-right position. 10 Toilet Seat Ring S3000: Changing blade Take hold of blade, situated at right, inner end of seat ring. Lift blade slightly, pull it forward and out of ring Warning: Blade is very sharp When the blade is removed from the seat ring, the number 1 should be visible (without turning the blade over) on the lower right corner. If you see the number 1, you may turn the blade over so that number 2 is visible on the lower right corner, and reinsert the blade – keeping the number 2 visible on the lower right corner. If the number 2 is on the lower right corner when you remove the blade, you will need to insert a fresh blade from the box. Take a fresh blade out of the box and insert it into the seat ring, always with the number 1 visible on the lower right corner. 11 Toilet Seat Ring S3000: Changing blade Close housing cover. Lower down and latch the seat ring in place. 12 Toilet Seat Ring S3000: Cleaning (Suggestion: Clean seat ring when the Hygoplast roll is changed) 1. Remove lid, open housing cover and take out power pack. 2. Remove both spools and pressure roller. 3. Release seat ring on the right side and lift it up. 4. Clean left and right compartments for Hygoplast rolls as well as pressure roller. 5. Remove blade and clean blade compartment. Warning: The blade is very sharp. 6. Lower down seat ring and insert power pack. 7. Reinsert pressure roller into its position. 8. Place new Hygoplast roll on left side or if it is not empty, put on spare roll sticker at end of Hygoplast, pull it over seat ring and insert roll sticker into slit on empty spool. 9. If the Hygoplast roll is new, press Reset. 10. Close housing cover. Important: a) If the seat ring is still wet, the Hygoplast roll may not pull properly over the ring. b) recommended cleaning products: ABS-cleaning products, Lysol-based products or window cleaning products without ammonia. c) Do not use under any circumstances the following: - Abrasive cleaning products - Chlorinated bleaching agent, bleaching agent with peroxide - Decalcifying products for toilet bowls - Solvents (Acetone, Toluene, etc.) - Ethereal oils 13 Toilet Seat Ring S3000: Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION No signal in LED display. No current. Insert power pack. Check contacts for battery. Check contacts for motor. LED display flashing. Empty or low voltage power pack. Change power pack. Only 1 bar visible in display. Nearly empty Hygoplast roll. Change Hygoplast roll and press "Reset". No pressure roller. Insert pressure roller. Pressure roller blocked. Clean roller or replace roller. Hygoplast is twisted. Using the palm of your hand, straighten plastic to untwist. Housing cover not completely closed. Close housing cover. Incorrect installation of roll. Reinstall roll. Seat ring is not correctly installed. Latch seat ring into clip and check position. Dull blade. Turn old blade over to the number 2 side or replace with new blade. No transport of Hygoplast or Hygoplast does not complete one revolution. 14 Toilet Seat Ring S3000: Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION Dull blade. Turn old blade over to the number 2 side or replace with new blade. Seat ring is damaged. Replace seat ring. Torn Hygoplast. For further information regarding problems not covered here, please contact our service department. Hygolet (USA) Inc 349 Southeast 2nd Avenue Deerfield Beach, FL 33441 Tel. : +1 800 494 6538 Fax : 954 481 8669 Email : [email protected] www.hygolet.com/usa Edition 08/11 15