TimberStrand, Microllam, and Parallam Beams
Transcription
TimberStrand, Microllam, and Parallam Beams
#TJ-9020 BEAMS, HEADERS, AND COLUMNS Specific to California and featuring Trus Joist® TimberStrand® LSL, Microllam® LVL, and Parallam® PSL •Uniform and Predictable •Minimal Bowing, Twisting, and Shrinking •Strong and Straight •Limited Product Warranty Regional guide featuring 2.2E Parallam® PSL and 2.0E Microllam® LVL headers and beams. SPECIFIER’S GUIDE CALIFORNIA Why Choose Trus Joist® Beams, Columns, and Headers? •Reliable performance •Consistent quality and dependable uniformity •Flexible solutions for your beam and header needs •Backed by a limited product warranty Using advanced technology, Weyerhaeuser manufactures engineered lumber that is consistently straight and strong, and resists bowing, twisting, and shrinking. That means less waste, easier installation, and higher design values for starters; plus fewer callbacks, shorter cycle times, more design flexibility, and lower overall installed cost in the end. Trus Joist® TimberStrand® LSL, Microllam® LVL, and Parallam® PSL are structural solutions you can count on—guaranteed. The products in this guide are readily available through our network of distributors and dealers. For more information on other applications or other Trus Joist® products, contact your Weyerhaeuser representative. This guide features Trus Joist® engineered lumber in the following widths and depths: TimberStrand® LSL TABLE OF CONTENTS Design Properties General Assumptions Floor Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Snow Roof Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Non-Snow Roof Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Beam Details Window and Door Header Details Nailing on Narrow Face Allowable Holes Bearing Length Requirements Tapered End Cuts Multiple-Member Connections Columns Product Warranty 4–5 5 6–7 8–9 10–11 12–13 14–15 16–17 18–19 20–21 22–23 24 24–25 25 26 26 27 28–29 30–31 32 1.55E TimberStrand® LSL sizes: Widths: 1¾" and 3½" Depths: 9½", 117⁄8", 14", and 16" 1.3E TimberStrand® LSL header sizes: Width: 3½" Depths: 43⁄8", 5½", 7¼", and 85⁄8" 1.3E TimberStrand® LSL column and post sizes: 3½" x 3½" 3½" x 43⁄8" 3½" x 5½" 31⁄2" x 7¼" 3½" x 85⁄8" Microllam® LVL 2.0E Microllam® LVL header and beam sizes: Width: 1¾" Depths: 5 ½", 7¼", 9½", 117⁄8", 14", 16", and 18" Parallam® PSL 2.2E Parallam® PSL header and beam sizes: Widths: 3½", 5¼", and 7" Depths: 9¼", 9½", 11¼", 117⁄8", 14", 16", and 18" 1.8E Parallam® PSL column and post sizes: 31⁄2" x 31⁄2" 31⁄2" x 51⁄4" 31⁄2" x 7" 51⁄4" x 51⁄4" 51⁄4" x 7" 7" x 7" For deeper depth Parallam® PSL beams, see the Trus Joist® 2.2E Parallam® PSL Deep Beam Guide, TJ-7001, or contact your Weyerhaeuser representative. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 2 Structural Solutions Trus Joist® TimberStrand® Laminated Strand Lumber (LSL) •One-piece members reduce labor time •Every piece is straight and strong •Unique properties allow you to drill larger holes through 1.55E TimberStrand® LSL. See Allowable Holes on page 26. TimberStrand® LSL Grade Verification TimberStrand® LSL is available in more than one grade. The product is stamped with its grade information, as shown in the examples below. With 1.55E TimberStrand® LSL, larger holes can be drilled through the beam. Actual stamps shown. Code Evaluations: See ICC ES ESR-1387 Trus Joist® Microllam® Laminated Veneer Lumber (LVL) • Can easily be built up on site to reduce heavy lifting •Offers reliable and economical solutions for beam and header applications •Manufacturing process minimizes many of the natural inconsistencies found in wood Code Evaluations: See ICC ES ESR-1387 Trus Joist® Parallam® Parallel Strand Lumber (PSL) •Allows long spans for open floor plans without intermediate posts or columns • Has warm, unique grain that is perfect for applications with exposed beams • Provides ideal solutions for cantilever and multi-span applications • Solid sections save time on site assembly •Available in some regions with preservative treatment for exterior applications Parallam® PSL Grade Verification Parallam® PSL is available in more than one grade. 2.2E Parallam® PSL is stamped with plant identification number 0575. Code Evaluations: See ICC ES ESR-1387 Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 3 dESIGN PROPERTIES Allowable Design Properties(1) (100% Load Duration) Depth Grade 1.3E Width 3 1⁄ 2 " 13 ⁄4" 1.55E 3 1⁄ 2 " 2.0E 13 ⁄4" 31⁄ 2 " 2.2E 51⁄4" 7" Design Property Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) 51 ⁄ 2 " Plank Orientation 4 3⁄ 8 " 51 ⁄ 2 " 1,735 2,685 TimberStrand ® LSL 1,780 4,550 6,335 4,340 5,455 1,925 7,190 8,555 24 4.5 49 5.6 20 5.6 111 7.4 187 8.8 Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) 71⁄4" 85⁄ 8" 9¼" Microllam ® LVL 3,555 2,410 56 3.7 Parallam ® PSL 2,125 1,830 24 2.8 Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) 12,415 6,260 231 10.1 18,625 9,390 346 15.2 24,830 12,520 462 20.2 9 1⁄ 2 " 11¼" 117⁄ 8" 14" 16" 5,210 3,435 125 5.2 10,420 6,870 250 10.4 7,975 4,295 244 6.5 15,955 8,590 488 13 10,920 5,065 400 7.7 21,840 10,125 800 15.3 14,090 5,785 597 8.8 28,180 11,575 1,195 17.5 5,885 3,160 125 4.8 8,925 3,950 244 6.1 12,130 4,655 400 7.1 15,555 5,320 597 8.2 17,970 19,900 27,160 34,955 43,665 6,430 250 7,615 415 8,035 488 9,475 800 10,825 1,195 12,180 1,701 10.4 19,585 9,645 12.3 26,955 11,420 13.0 29,855 12,055 15.3 40,740 14,210 17.5 52,430 16,240 19.7 65,495 18,270 375 623 733 1,201 1,792 2,552 15.6 26,115 12,855 18.5 35,940 15,225 19.5 39,805 16,070 23.0 54,325 18,945 26.3 69,905 21,655 29.5 87,325 24,360 500 20.8 831 24.6 977 26.0 1,601 30.6 2,389 35.0 3,402 39.4 Protect product from sun and water om oist.c 58 TrusJ 53.83 888.4 m t.co 8 Jois Trus.453.835 t.com8 Jois .835 Trus.453 888 888 m t.co 8 Jois.835 Trus.453 com ist. 58 sJo .83 Tru 53 888 8.4 88 m ist.co58 sJo .83 Tru 53 CAUTION: Wrap is slippery when wet or icy .com Joist8358 Trus453. 888. Use support blocks (6x6 or larger) at 10' on-center to keep bundles out of mud and water Align stickers (2x3 or larger) directly over support blocks 8.4 88 Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 4 19,375 5,985 851 9.2 13,055 (1) For product in beam orientation, unless otherwise noted. Product Storage 18" Design Properties Design Stresses(1) (100% Load Duration) Orientation G Shear Modulus of Elasticity (psi) E Modulus of Elasticity (psi) E min Adjusted Modulus of Elasticity (2) (psi) 1.55E Beam/Column Plank Beam 81,250 81,250 96,875 1.3 x 106 1.3 x 106 1.55 x 106 660,750 660,750 787,815 2.0E Beam 125,000 2.0 x 106 1,016,535 1.8E 2.2E Column Beam 112,500 137,500 1.8 x 106 2.2 x 106 914,880 1,118,190 Grade 1.3E Fb Flexural Stress (3) (psi) TimberStrand ® LSL 1,700 1,075 1,900(8) 1,075 2,325 1,070(10) Microllam ® LVL 2,600 1,555 Parallam ® PSL 2,400(11) 1,755 2,900 2,025 (1)Unless otherwise noted, adjustment to the design stresses for duration of load are permitted in accordance with the applicable code. (2)Reference modulus of elasticity for beam and column stability calculations, per NDS®. (3)For 12" depth. For other depths, multiply Fb by the appropriate factor as follows: – For [ ] LVL, multiply by [ ] PSL, multiply by [ ] 12 0.092 d 12 0.136 d 12 0.111 d – For Parallam® (4)Ft has been adjusted to reflect the volume effects for most standard applications. (5)Fc⊥ may not be increased for duration of load. General Assumptions for Trus Joist® Beams ■ ■ 710 635(9) 900 1,835 1,835 2,170 750 2,510 545(11) 625 2,500 2,900(12) 425 150 310(10) 285 190(11) 290 Beam Orientation Lateral support is required at bearing and along the span at 24" on-center, maximum. Bearing lengths are based on each product’s bearing stress for applicable grade and orientation. ■ All members 71⁄4" and less in depth are restricted to a maximum deflection of 5⁄16". ■ Beams that are 13⁄4" x 16" and deeper require multiple plies. ■ camber. No ■ Fcll Fv Fc⊥ Horizontal Compression Compression Parallel Shear Parallel Perpendicular to Grain to Grain to Grain (5) (psi) (psi) (psi) SG Equivalent Specific Gravity (6) 0.50(7) 0.50(7) 0.50(7) 0.50 0.50 0.50 (6)For lateral connection design only. (7)Specific gravity of 0.58 may be used for bolts installed perpendicular to face and loaded perpendicular to grain. (8)Values are for thickness up to 31⁄2". (9)For members less than 1¾" thick and in plank orientation, use Fc⊥ of 670 psi. NDS® bearing area factor Cb = 1.0. (10)Value accounts for large hole capabilities. See Allowable Holes on page 26. (11)Value shown is for plank orientation. (12)For column applications, use Fcll of 500 psi. Alternatively, refer to ESR-1387, Table 1, footnote 15. – For TimberStrand® LSL, multiply by Microllam® Ft Tension Stress (4) (psi) Beams and columns must remain straight to within 5L2⁄4608 (in.) of true alignment. L is the unrestrained length of the member in feet. For applications not covered in this brochure, contact your Weyerhaeuser representative. Column Orientation See pages 28 and 29 for multiple-member beam connections. TimberStrand ® LSL, Microllam ® LVL, and untreated Parallam ® PSL are intended for dry-use applications Plank Orientation Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 5 Floor Load Tables How to Use This Table 1.Calculate total and live load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total and live loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 7. TimberStrand® LSL: Floor—100% (PLF) Span 3' 4' 5' 6' 7' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 24' 28' 1.3E Grade Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) 4 3⁄ 8" 1,538 1,420 1.5/3.5 863 651 1.5/3.5 517 347 1.5/3.5 304 206 1.5/3.5 171 131 1.5/3.5 99 89 1.5/3.5 31⁄2" Width 51 ⁄ 2 " 71⁄4" 2,381 4,036 * * 1.5/3.6 2.4/6.1 1,337 2,267 1,215 * 1.5/3.5 1.8/4.6 853 1,448 662 1,398 1.5/3.5 1.5/3.7 590 1,003 397 857 1.5/3.5 1.5/3.5 336 735 255 560 1.5/3.5 1.5/3.5 198 443 173 384 1.5/3.5 1.5/3.5 98 224 * * 1.5/3.5 1.5/3.5 79 182 * * 1.5/3.5 1.5/3.5 85 * 1.5/3.5 85 ⁄ 8" 5,624 * 3.4/8.5 3,159 * 2.6/6.4 2,019 * 2/5.1 1,399 1,367 1.7/4.3 1,025 904 1.5/3.6 783 626 1.5/3.5 552 386 1.5/3.5 492 333 1.5/3.5 287 197 1.5/3.5 180 126 1.5/3.5 108 77 1.5/3.5 74 55 1.5/3.5 57 44 1.5/3.5 1.55E Grade 51⁄2" Plank Orientation 31 ⁄ 2 " 1,210 * 1.5/3.5 814 546 1.5/3.5 425 287 1.5/3.5 248 169 1.5/3.5 138 107 1.5/3.5 79 72 1.5/3.5 91⁄ 2 " 3,166 * 3/7.6 2,006 * 2.6/6.4 1,467 * 2.3/5.8 1,152 1,048 2.2/5.5 845 699 1.9/4.7 646 487 1.7/4.1 448 302 1.5/3.5 387 261 1.5/3.5 228 155 1.5/3.5 144 99 1.5/3.5 87 61 1.5/3.5 60 44 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 6 13⁄4" Width 117⁄ 8" 4,717 * 4.5/11.3 2,836 * 3.6/9 2,004 * 3.2/8 1,549 * 3/7.4 1,262 1,250 2.8/7 990 886 2.5/6.3 700 560 2.1/5.3 631 487 2/5.1 434 293 1.7/4.2 278 189 1.5/3.5 170 118 1.5/3.5 120 84 1.5/3.5 94 67 1.5/3.5 52 39 1.5/3.5 14" 4,717 * 4.5/11.3 3,536 * 4.5/11.3 2,577 * 4.1/10.3 1,952 * 3.7/9.3 1,570 * 3.5/8.8 1,313 * 3.4/8.4 960 870 2.9/7.3 865 760 2.8/6.9 599 464 2.3/5.8 438 302 2/5 277 189 1.5/3.7 197 136 1.5/3.5 156 109 1.5/3.5 88 64 1.5/3.5 53 40 1.5/3.5 Floor Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). –More restrictive of simple or continuous span. –Deflection criteria of L/240 total load (TL) and L/360 live load (LL). For live load deflection limits of L/240 or L/480, multiply Live Load L/360 values by 1.5 or 0.75, respectively. The resulting live load must not exceed the total load shown. Also see How to Use this Table on page 6 and General Assumptions on page 5. TimberStrand® LSL: Floor—100% (PLF) continued Span 3' 4' 5' 6' 7' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 24' 28' 1.55E Grade Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) 91⁄ 2 " 6,332 * 3/7.6 4,012 * 2.6/6.4 2,934 * 2.3/5.8 2,305 2,097 2.2/5.5 1,691 1,399 1.9/4.7 1,292 974 1.7/4.1 897 605 1.5/3.5 775 523 1.5/3.5 456 311 1.5/3.5 288 199 1.5/3.5 174 123 1.5/3.5 121 88 1.5/3.5 94 70 1.5/3.5 31⁄2" Width 117⁄ 8" 14" 9,432 9,432 * * 4.5/11.3 4.5/11.3 5,673 7,070 * * 3.6/9 4.5/11.3 4,009 5,155 * * 3.2/8 4.1/10.3 3,098 3,904 * * 3/7.4 3.7/9.3 2,524 3,141 2,501 * 2.8/7 3.5/8.8 1,981 2,626 1,773 * 2.5/6.3 3.4/8.4 1,401 1,920 1,121 1,740 2.1/5.3 2.9/7.3 1,263 1,731 974 1,520 2/5.1 2.8/6.9 868 1,198 587 928 1.7/4.2 2.3/5.8 556 876 379 605 1.5/3.5 2/5 341 554 236 379 1.5/3.5 1.5/3.7 241 395 169 273 1.5/3.5 1.5/3.5 189 312 135 218 1.5/3.5 1.5/3.5 105 177 79 128 1.5/3.5 1.5/3.5 62 107 50 81 1.5/3.5 1.5/3.5 16" 9,432 * 4.5/11.3 7,070 * 4.5/11.3 5,652 * 4.5/11.3 4,707 * 4.5/11.3 3,787 * 4.2/10.6 3,138 * 4/10 2,480 2,456 3.8/9.4 2,236 2,154 3.6/8.9 1,547 1,334 3/7.5 1,132 877 2.6/6.4 810 555 2.2/5.4 584 401 1.8/4.4 463 320 1.5/3.8 266 189 1.5/3.5 163 120 1.5/3.5 91⁄ 2 " 9,499 * 3/7.6 6,018 * 2.6/6.4 4,401 * 2.3/5.8 3,458 3,146 2.2/5.5 2,536 2,098 1.9/4.7 1,938 1,462 1.7/4.1 1,346 907 1.5/3.5 1,162 785 1.5/3.5 685 467 1.5/3.5 433 299 1.5/3.5 262 185 1.5/3.5 182 132 1.5/3.5 142 105 1.5/3.5 76 61 1.5/3.5 51⁄4" Width (2- or 3-ply) 117⁄ 8" 14" 14,148 14,148 * * 4.5/11.3 4.5/11.3 8,510 10,605 * * 3.6/9 4.5/11.3 6,014 7,733 * * 3.2/8 4.1/10.3 4,648 5,857 * * 3/7.4 3.7/9.3 3,786 4,711 3,752 * 2.8/7 3.5/8.8 2,971 3,939 2,660 * 2.5/6.3 3.4/8.4 2,101 2,880 1,681 2,610 2.1/5.3 2.9/7.3 1,894 2,597 1,462 2,280 2/5.1 2.8/6.9 1,302 1,797 881 1,393 1.7/4.2 2.3/5.8 834 1,314 569 907 1.5/3.5 2/5 512 831 354 569 1.5/3.5 1.5/3.7 362 592 254 410 1.5/3.5 1.5/3.5 284 468 202 327 1.5/3.5 1.5/3.5 158 265 118 192 1.5/3.5 1.5/3.5 93 160 75 122 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 7 16" 14,148 * 4.5/11.3 10,605 * 4.5/11.3 8,478 * 4.5/11.3 7,061 * 4.5/11.3 5,681 * 4.2/10.6 4,708 * 4/10 3,720 3,684 3.8/9.4 3,355 3,232 3.6/8.9 2,321 2,001 3/7.5 1,698 1,316 2.6/6.4 1,215 832 2.2/5.4 876 601 1.8/4.4 695 481 1.5/3.8 400 284 1.5/3.5 245 181 1.5/3.5 Floor Load Tables How to Use This Table 1.Calculate total and live load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total and live loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 9. 2.0E Microllam® LVL: Floor—100% (PLF) Span 6' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 22' 24' 26' 28' 30' Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) 5½" 455 305 1.5/3.5 153 133 1.5/3.5 77 * 1.5/3.5 62 * 1.5/3.5 7¼" 762 659 1.8/4.4 342 295 1.5/3.5 174 * 1.5/3.5 142 * 1.5/3.5 67 * 1.5/3.5 1¾" Width 9½" 1,062 * 2.4/6.1 731 628 2.2/5.6 517 390 1.9/4.7 466 337 1.8/4.5 296 200 1.5/3.5 188 128 1.5/3.5 114 79 1.5/3.5 80 56 1.5/3.5 62 45 1.5/3.5 117⁄8" 1,424 * 3.3/8.2 978 * 3/7.5 784 723 2.9/7.2 707 628 2.7/6.8 489 379 2.3/5.7 358 244 1.9/4.9 222 152 1.5/3.6 158 109 1.5/3.5 124 87 1.5/3.5 92 65 1.5/3.5 70 51 1.5/3.5 54 40 1.5/3.5 14" 1,794 * 4.1/10.3 1,207 * 3.7/9.3 968 * 3.5/8.8 908 * 3.5/8.7 666 599 3.1/7.7 487 390 2.6/6.6 349 245 2.2/5.6 257 176 1.9/4.7 204 140 1.6/4 152 106 1.5/3.5 117 82 1.5/3.5 91 65 1.5/3.5 71 52 1.5/3.5 57 42 1.5/3.5 5½" 910 610 1.5/3.5 307 267 1.5/3.5 154 * 1.5/3.5 124 * 1.5/3.5 57 * 1.5/3.5 3½" Width (2-ply) 7¼" 9½" 1,525 2,125 1,319 * 1.8/4.4 2.4/6.1 685 1,462 591 1,257 1.5/3.5 2.2/5.6 349 1,034 780 * 1.5/3.5 1.9/4.7 284 932 675 * 1.5/3.5 1.8/4.5 135 593 401 * 1.5/3.5 1.5/3.5 70 376 257 * 1.5/3.5 1.5/3.5 229 159 1.5/3.5 161 113 1.5/3.5 125 90 1.5/3.5 92 68 1.5/3.5 69 52 1.5/3.5 52 41 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 8 117⁄8" 2,848 * 3.3/8.2 1,956 * 3/7.5 1,569 1,446 2.9/7.2 1,415 1,257 2.7/6.8 979 758 2.3/5.7 716 489 1.9/4.9 445 305 1.5/3.6 316 218 1.5/3.5 249 174 1.5/3.5 185 131 1.5/3.5 140 102 1.5/3.5 108 80 1.5/3.5 84 64 1.5/3.5 66 52 1.5/3.5 Floor Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. – Deflection criteria of L/240 total load (TL) and L/360 live load (LL). For live load deflection limits of L/240 or L/480, multiply Live Load L/360 values by 1.5 or 0.75, respectively. The resulting live load must not exceed the total load shown. Also see How to Use This Table on page 8 and General Assumptions on page 5. 2.0E Microllam® LVL: Floor—100% (PLF) continued Span 6' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 22' 24' 26' 28' 30' Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) 14" 3,589 * 4.1/10.3 2,414 * 3.7/9.3 1,937 * 3.5/8.8 1,817 * 3.5/8.7 1,333 1,198 3.1/7.7 975 780 2.6/6.6 698 490 2.2/5.6 515 352 1.9/4.7 408 281 1.6/4 305 213 1.5/3.5 234 165 1.5/3.5 182 130 1.5/3.5 143 105 1.5/3.5 114 85 1.5/3.5 31 ⁄ 2" Width (2-ply) 16" 18" 3,919 3,919 * * 4.5/11.3 4.5/11.3 2,885 2,934 * * 4.4/11.1 4.5/11.3 2,294 2,468 * * 4.2/10.5 4.5/11.3 2,147 2,344 * * 4.1/10.3 4.5/11.3 1,709 1,950 * * 3.9/9.9 4.5/11.3 1,253 1,563 1,132 1,561 3.4/8.5 4.2/10.5 897 1,120 716 995 2.9/7.2 3.6/8.9 710 887 517 722 2.6/6.4 3.2/8 604 756 414 579 2.4/5.9 3/7.4 455 622 314 441 2/4.9 2.7/6.7 350 497 244 343 1.7/4.2 2.4/5.9 274 390 193 272 1.5/3.6 2/5.1 217 311 155 219 1.5/3.5 1.8/4.4 174 127 1.5/3.5 5½" 1,366 916 1.5/3.5 461 401 1.5/3.5 231 * 1.5/3.5 187 * 1.5/3.5 86 * 1.5/3.5 251 179 1.5/3.9 7¼" 2,287 1978 1.8/4.4 1,028 887 1.5/3.5 524 * 1.5/3.5 427 * 1.5/3.5 203 * 1.5/3.5 106 * 1.5/3.5 9½" 3,188 * 2.4/6.1 2,193 1,886 2.2/5.6 1,551 1,171 1.9/4.7 1,398 1,013 1.8/4.5 889 602 1.5/3.5 564 386 1.5/3.5 343 238 1.5/3.5 241 170 1.5/3.5 188 135 1.5/3.5 138 102 1.5/3.5 104 79 1.5/3.5 78 62 1.5/3.5 60 50 1.5/3.5 51⁄4" Width (3-ply) 117⁄8" 14" 4,272 5,384 * * 3.3/8.2 4.1/10.3 2,935 3,621 * * 3/7.5 3.7/9.3 2,354 2,905 2,170 * 2.9/7.2 3.5/8.8 2,123 2,725 1,886 * 2.7/6.8 3.5/8.7 1,469 2,000 1,137 1,797 2.3/5.7 3.1/7.7 1,074 1,463 734 1,171 1.9/4.9 2.6/6.6 668 1,047 457 735 1.5/3.6 2.2/5.6 474 772 328 529 1.5/3.5 1.9/4.7 374 612 261 422 1.5/3.5 1.6/4 278 458 197 320 1.5/3.5 1.5/3.5 211 351 153 248 1.5/3.5 1.5/3.5 163 273 120 196 1.5/3.5 1.5/3.5 127 215 97 157 1.5/3.5 1.5/3.5 100 79 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 9 171 128 1.5/3.5 16" 5,878 * 4.5/11.3 4,328 * 4.4/11.1 3,441 * 4.2/10.5 3,221 * 4.1/10.3 2,563 * 3.9/9.9 1,880 1,698 3.4/8.5 1,346 1,074 2.9/7.2 1,066 776 2.6/6.4 907 621 2.4/5.9 683 472 2/4.9 525 366 1.7/4.2 411 290 1.5/3.6 326 233 1.5/3.5 18" 5,878 * 4.5/11.3 4,402 * 4.5/11.3 3,702 * 4.5/11.3 3,516 * 4.5/11.3 2,925 * 4.5/11.3 2,345 2,342 4.2/10.5 1,680 1,493 3.6/8.9 1,331 1,084 3.2/8 1,135 869 3/7.4 933 662 2.7/6.7 746 515 2.4/5.9 586 409 2/5.1 467 329 1.8/4.4 261 190 1.5/3.5 376 269 1.5/3.9 Floor Load Tables How to Use This Table 1.Calculate total and live load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total and live loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 11. 2.2E Parallam® PSL: Floor—100% (PLF) Span Condition Total Load 8' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 10' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 12' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 14' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 20' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 22' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 24' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 26' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 28' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 30' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 32' Live Load L/360 Min. End/Int. Bearing (in.) 9¼" 1,469 1,286 2.7/6.8 1,090 796 2.4/6 983 689 2.3/5.7 604 409 1.7/4.2 382 261 1.5/3.5 232 162 1.5/3.5 163 115 1.5/3.5 127 91 1.5/3.5 93 69 1.5/3.5 70 53 1.5/3.5 53 42 1.5/3.5 9½" 1,517 1,383 2.8/7 1,147 858 2.5/6.3 1,034 743 2.4/6 652 442 1.8/4.5 414 283 1.5/3.5 252 175 1.5/3.5 177 125 1.5/3.5 138 99 1.5/3.5 102 75 1.5/3.5 76 57 1.5/3.5 58 45 1.5/3.5 11¼" 1,861 * 3.4/8.6 1,510 1,373 3.3/8.3 1,420 1,192 3.3/8.2 986 716 2.7/6.8 679 461 2.2/5.5 418 287 1.6/4.1 296 205 1.5/3.5 233 163 1.5/3.5 173 123 1.5/3.5 131 95 1.5/3.5 100 75 1.5/3.5 78 60 1.5/3.5 61 49 1.5/3.5 3½" Width 117⁄ 8" 1,990 * 3.7/9.2 1,611 1,591 3.5/8.8 1,514 1,383 3.5/8.7 1,092 834 3/7.6 795 538 2.6/6.5 490 335 1.9/4.7 348 240 1.5/3.8 274 191 1.5/3.5 204 144 1.5/3.5 155 112 1.5/3.5 119 88 1.5/3.5 93 71 1.5/3.5 73 57 1.5/3.5 58 47 1.5/3.5 14" 2,441 * 4.5/11.3 1,970 * 4.3/10.8 1,848 * 4.3/10.6 1,480 1,318 4.1/10.3 1,093 858 3.5/8.9 782 539 3/7.5 567 388 2.5/6.2 449 309 2.1/5.3 336 234 1.8/4.4 257 182 1.5/3.7 200 143 1.5/3.5 158 115 1.5/3.5 126 94 1.5/3.5 101 78 1.5/3.5 16" 2,441 * 4.5/11.3 2,052 * 4.5/11.3 1,949 * 4.5/11.3 1,620 * 4.5/11.3 1,386 1,245 4.5/11.3 1,009 787 3.9/9.7 799 569 3.5/8.6 665 455 3.1/7.8 501 346 2.6/6.5 385 268 2.2/5.5 301 212 1.9/4.7 239 171 1.6/4.1 192 139 1.5/3.6 156 115 1.5/3.5 18" 2,441 * 4.5/11.3 2,052 * 4.5/11.3 1,949 * 4.5/11.3 1,620 * 4.5/11.3 1,386 * 4.5/11.3 1,173 1,095 4.5/11.3 1,000 795 4.3/10.8 853 637 4/10 702 485 3.6/9.1 547 378 3.1/7.8 430 300 2.7/6.7 343 241 2.3/5.8 276 197 2/5.1 225 163 1.8/4.5 9¼" 2,204 1,929 2.7/6.8 1,635 1,195 2.4/6 1,474 1,034 2.3/5.7 906 614 1.7/4.2 574 392 1.5/3.5 349 243 1.5/3.5 245 173 1.5/3.5 191 137 1.5/3.5 140 104 1.5/3.5 105 80 1.5/3.5 79 63 1.5/3.5 61 50 1.5/3.5 9½" 2,275 2,075 2.8/7 1,720 1,288 2.5/6.3 1,551 1,115 2.4/6 979 663 1.8/4.5 621 424 1.5/3.5 378 262 1.5/3.5 266 187 1.5/3.5 208 149 1.5/3.5 153 112 1.5/3.5 114 86 1.5/3.5 87 68 1.5/3.5 66 55 1.5/3.5 51 44 1.5/3.5 11¼" 2,792 * 3.4/8.6 2,265 2,059 3.3/8.3 2,130 1,788 3.3/8.2 1,479 1,074 2.7/6.8 1,019 692 2.2/5.5 627 430 1.6/4.1 444 308 1.5/3.5 349 245 1.5/3.5 259 185 1.5/3.5 196 143 1.5/3.5 151 113 1.5/3.5 117 90 1.5/3.5 92 74 1.5/3.5 73 61 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 10 51/4" Width 117⁄ 8" 2,985 * 3.7/9.2 2,416 2,387 3.5/8.8 2,271 2,075 3.5/8.7 1,639 1,251 3/7.6 1,192 808 2.6/6.5 736 503 1.9/4.7 522 361 1.5/3.8 412 287 1.5/3.5 306 217 1.5/3.5 233 168 1.5/3.5 179 132 1.5/3.5 140 106 1.5/3.5 110 86 1.5/3.5 88 71 1.5/3.5 14" 3,661 * 4.5/11.3 2,955 * 4.3/10.8 2,772 * 4.3/10.6 2,220 1,977 4.1/10.3 1,639 1,288 3.5/8.9 1,174 808 3/7.5 850 582 2.5/6.2 674 464 2.1/5.3 505 352 1.8/4.4 386 273 1.5/3.7 300 215 1.5/3.5 237 173 1.5/3.5 189 141 1.5/3.5 152 117 1.5/3.5 16" 3,661 * 4.5/11.3 3,079 * 4.5/11.3 2,923 * 4.5/11.3 2,431 * 4.5/11.3 2,079 1,868 4.5/11.3 1,514 1,181 3.9/9.7 1,199 854 3.5/8.6 998 683 3.1/7.8 752 519 2.6/6.5 578 403 2.2/5.5 452 319 1.9/4.7 359 257 1.6/4.1 288 209 1.5/3.6 234 173 1.5/3.5 18" 3,661 * 4.5/11.3 3,079 * 4.5/11.3 2,923 * 4.5/11.3 2,431 * 4.5/11.3 2,079 * 4.5/11.3 1,760 1,642 4.5/11.3 1,501 1,192 4.3/10.8 1,280 956 4/10 1,053 728 3.6/9.1 821 567 3.1/7.8 645 450 2.7/6.7 514 362 2.3/5.8 415 296 2/5.1 338 245 1.8/4.5 Floor Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. – Deflection criteria of L/240 total load (TL) and L/360 live load (LL). For live load deflection limits of L/240 or L/480, multiply Live Load L/360 values by 1.5 or 0.75, respectively. The resulting live load must not exceed the total load shown. Also see How to Use This Table on page 10 and General Assumptions on page 5. 2.2E Parallam® PSL: Floor—100% (PLF) continued Span 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 22' 24' 26' 28' 30' 32' Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load Live Load L/360 Min. End/Int. Bearing (in.) 9¼" 2,939 2,572 2.7/6.8 2,180 1,593 2.4/6 1,966 1,378 2.3/5.7 1,208 818 1.7/4.2 765 523 1.5/3.5 465 324 1.5/3.5 326 231 1.5/3.5 255 183 1.5/3.5 187 138 1.5/3.5 140 107 1.5/3.5 106 84 1.5/3.5 81 67 1.5/3.5 62 55 1.5/3.5 9½" 3,034 2,767 2.8/7 2,294 1,717 2.5/6.3 2,068 1,486 2.4/6 1,305 884 1.8/4.5 828 566 1.5/3.5 504 350 1.5/3.5 354 250 1.5/3.5 277 198 1.5/3.5 204 150 1.5/3.5 153 115 1.5/3.5 116 91 1.5/3.5 89 73 1.5/3.5 68 59 1.5/3.5 53 49 1.5/3.5 11¼" 3,723 * 3.4/8.6 3,020 2,746 3.3/8.3 2,841 2,385 3.3/8.2 1,972 1,432 2.7/6.8 1,359 922 2.2/5.5 836 574 1.6/4.1 592 411 1.5/3.5 466 327 1.5/3.5 346 247 1.5/3.5 262 191 1.5/3.5 201 151 1.5/3.5 157 121 1.5/3.5 123 98 1.5/3.5 97 81 1.5/3.5 7" Width 117⁄ 8" 3,981 * 3.7/9.2 3,222 3,182 3.5/8.8 3,029 2,767 3.5/8.7 2,185 1,668 3/7.6 1,590 1,077 2.6/6.5 981 671 1.9/4.7 696 481 1.5/3.8 549 383 1.5/3.5 409 289 1.5/3.5 310 224 1.5/3.5 239 177 1.5/3.5 187 142 1.5/3.5 147 115 1.5/3.5 117 95 1.5/3.5 14" 4,882 * 4.5/11.3 3,940 * 4.3/10.8 3,696 * 4.3/10.6 2,960 2,636 4.1/10.3 2,186 1,717 3.5/8.9 1,565 1,078 3/7.5 1,134 776 2.5/6.2 898 619 2.1/5.3 673 469 1.8/4.4 515 364 1.5/3.7 401 287 1.5/3.5 316 231 1.5/3.5 252 188 1.5/3.5 203 156 1.5/3.5 16" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,773 2,490 4.5/11.3 2,019 1,575 3.9/9.7 1,599 1,139 3.5/8.6 1,331 911 3.1/7.8 1,003 692 2.6/6.5 771 537 2.2/5.5 603 425 1.9/4.7 479 342 1.6/4.1 384 279 1.5/3.6 312 231 1.5/3.5 18" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,773 * 4.5/11.3 2,346 2,190 4.5/11.3 2,001 1,590 4.3/10.8 1,707 1,275 4/10 1,404 971 3.6/9.1 1,095 756 3.1/7.8 860 600 2.7/6.7 686 483 2.3/5.8 553 395 2/5.1 451 327 1.8/4.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 11 Snow Roof Load Tables How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 13. TimberStrand® LSL: Roof—Snow Load Area 115% (PLF) Span 3' 4' 5' 6' 7' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 24' 28' 1.3E Grade Condition Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 4 3 ⁄8" 1,769 */1,420 1.5/3.5 993 977/651 1.5/3.5 634 521/347 1.5/3.5 317 309/206 1.5/3.5 171 */131 1.5/3.5 99 */89 1.5/3.5 31 ⁄ 2" Width 51 ⁄ 2 " 71 ⁄4" 2,739 4,643 */2,547 */* 1.7/4.1 2.8/7 1,538 2,608 */1,215 */2,476 1.5/3.5 2.1/5.3 982 1,666 */662 */1,398 1.5/3.5 1.7/4.2 614 1,155 595/397 */857 1.5/3.5 1.5/3.5 336 742 */255 */560 1.5/3.5 1.5/3.5 198 443 */173 */384 1.5/3.5 1.5/3.5 98 224 */* */* 1.5/3.5 1.5/3.5 79 182 */* */* 1.5/3.5 1.5/3.5 85 */* 1.5/3.5 8 5 ⁄8" 6,469 */* 3.9/9.8 3,635 */* 2.9/7.3 2,323 */2,188 2.3/5.9 1,610 */1,367 2/4.9 1,181 */904 1.7/4.2 902 */626 1.5/3.7 637 579/386 1.5/3.5 574 500/333 1.5/3.5 386 296/197 1.5/3.5 243 189/126 1.5/3.5 147 116/77 1.5/3.5 102 83/55 1.5/3.5 79 66/44 1.5/3.5 1.55E Grade 51 ⁄ 2" Plank Orientation 31 ⁄ 2 " 1,392 */1,224 1.5/3.5 996 820/546 1.5/3.5 533 431/287 1.5/3.5 258 253/169 1.5/3.5 138 */107 1.5/3.5 79 */72 1.5/3.5 91⁄ 2 " 3,642 */* 3.5/8.7 2,307 */* 2.9/7.3 1,688 */1,658 2.7/6.7 1,326 */1,048 2.5/6.3 973 */699 2.2/5.4 743 731/487 1.9/4.8 525 453/302 1.6/4 474 392/261 1.5/3.8 306 233/155 1.5/3.5 194 149/99 1.5/3.5 118 92/61 1.5/3.5 83 66/44 1.5/3.5 64 52/35 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 12 13 ⁄ 4" Width 117⁄ 8" 4,717 */* 4.5/11.3 3,263 */* 4.2/10.4 2,306 */* 3.7/9.2 1,782 */* 3.4/8.5 1,452 */1,250 3.2/8.1 1,140 */886 2.9/7.3 806 */560 2.5/6.1 727 */487 2.3/5.8 503 440/293 1.9/4.9 367 284/189 1.7/4.2 230 177/118 1.5/3.5 163 127/84 1.5/3.5 128 101/67 1.5/3.5 72 59/39 1.5/3.5 14" 4,717 */* 4.5/11.3 3,536 */* 4.5/11.3 2,827 */* 4.5/11.3 2,246 */* 4.3/10.7 1,807 */* 4/10.1 1,511 */1,352 3.9/9.6 1,105 */870 3.4/8.4 996 */760 3.2/8 690 */464 2.7/6.6 504 453/302 2.3/5.7 361 284/189 1.9/4.8 265 205/136 1.6/4 210 163/109 1.5/3.5 120 96/64 1.5/3.5 73 61/40 1.5/3.5 Snow Roof Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. For door and window applications, Weyerhaeuser recommends using the L/360 value for a live load deflection limit and the L/240 value for a total load limit. Also see How to Use This Table on page 12 and General Assumptions on page 5. TimberStrand® LSL: Roof—Snow Load Area 115% (PLF) continued Span 3' 4' 5' 6' 7' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 24' 28' 1.55E Grade Condition Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 91⁄ 2 " 7,284 */* 3.5/8.7 4,615 */* 2.9/7.3 3,376 */3,316 2.7/6.7 2,652 */2,097 2.5/6.3 1,946 */1,399 2.2/5.4 1,487 1,462/974 1.9/4.8 1,051 907/605 1.6/4 948 785/523 1.5/3.8 612 467/311 1.5/3.5 388 299/199 1.5/3.5 236 185/123 1.5/3.5 166 132/88 1.5/3.5 129 105/70 1.5/3.5 71 61/40 1.5/3.5 31⁄2" Width 117⁄ 8" 14" 9,432 9,432 */* */* 4.5/11.3 4.5/11.3 6,526 7,070 */* */* 4.2/10.4 4.5/11.3 4,612 5,652 */* */* 3.7/9.2 4.5/11.3 3,565 4,492 */* */* 3.4/8.5 4.3/10.7 2,904 3,614 */2,501 */* 3.2/8.1 4/10.1 2,280 3,022 */1,773 */2,705 2.9/7.3 3.9/9.6 1,613 2,211 */1,121 */1,740 2.5/6.1 3.4/8.4 1,454 1,993 */974 */1,520 2.3/5.8 3.2/8 1,006 1,380 881/587 */928 1.9/4.9 2.7/6.6 735 1,009 569/379 907/605 1.7/4.2 2.3/5.7 460 722 354/236 569/379 1.5/3.5 1.9/4.8 326 531 254/169 410/273 1.5/3.5 1.6/4 257 421 202/135 327/218 1.5/3.5 1.5/3.5 145 241 118/79 192/128 1.5/3.5 1.5/3.5 87 147 75/50 122/81 1.5/3.5 1.5/3.5 16" 9,432 */* 4.5/11.3 7,070 */* 4.5/11.3 5,652 */* 4.5/11.3 4,707 */* 4.5/11.3 4,032 */* 4.5/11.3 3,526 */* 4.5/11.3 2,854 */2,456 4.3/10.8 2,574 */2,154 4.1/10.3 1,782 */1,334 3.4/8.6 1,305 */877 2.9/7.3 934 832/555 2.5/6.2 739 601/401 2.2/5.6 624 481/320 2/5.1 361 284/189 1.5/3.6 224 181/120 1.5/3.5 91⁄ 2 " 10,926 */* 3.5/8.7 6,923 */* 2.9/7.3 5,064 */4,975 2.7/6.7 3,979 */3,146 2.5/6.3 2,919 */2,098 2.2/5.4 2,231 2,193/1,462 1.9/4.8 1,577 1,361/907 1.6/4 1,422 1,178/785 1.5/3.8 918 700/467 1.5/3.5 582 448/299 1.5/3.5 354 277/185 1.5/3.5 249 198/132 1.5/3.5 194 157/105 1.5/3.5 106 91/61 1.5/3.5 61 58/38 1.5/3.5 51⁄4" Width (2- or 3-ply) 117⁄ 8" 14" 14,148 14,148 */* */* 4.5/11.3 4.5/11.3 9,790 10,605 */* */* 4.2/10.4 4.5/11.3 6,919 8,478 */* */* 3.7/9.2 4.5/11.3 5,348 6,739 */* */* 3.4/8.5 4.3/10.7 4,357 5,421 */3,752 */* 3.2/8.1 4/10.1 3,420 4,534 */2,660 */4,058 2.9/7.3 3.9/9.6 2,419 3,316 */1,681 */2,610 2.5/6.1 3.4/8.4 2,182 2,990 */1,462 */2,280 2.3/5.8 3.2/8 1,509 2,070 1,322/881 */1,393 1.9/4.9 2.7/6.6 1,103 1,514 854/569 1,361/907 1.7/4.2 2.3/5.7 690 1,084 532/354 854/569 1.5/3.5 1.9/4.8 489 797 381/254 615/410 1.5/3.5 1.6/4 385 631 304/202 491/327 1.5/3.5 1.5/3.5 217 361 177/118 288/192 1.5/3.5 1.5/3.5 130 221 112/75 183/122 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 13 16" 14,148 */* 4.5/11.3 10,605 */* 4.5/11.3 8,478 */* 4.5/11.3 7,061 */* 4.5/11.3 6,048 */* 4.5/11.3 5,289 */* 4.5/11.3 4,282 */3,684 4.3/10.8 3,862 */3,232 4.1/10.3 2,674 */2,001 3.4/8.6 1,957 */1,316 2.9/7.3 1,402 1,248/832 2.5/6.2 1,109 902/601 2.2/5.6 936 722/481 2/5.1 542 426/284 1.5/3.6 336 271/181 1.5/3.5 Snow Roof Load Tables How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2. Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 15. 2.0E Microllam® LVL: Roof—Snow Load Area 115% (PLF) Span 6' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 22' 24' 26' 28' 30' Condition Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) 51 ⁄ 2 " 474 458 1.5/3.5 153 * 1.5/3.5 77 * 1.5/3.5 62 * 1.5/3.5 71 ⁄4" 877 * 2/5 342 * 1.5/3.5 174 * 1.5/3.5 142 * 1.5/3.5 67 * 1.5/3.5 13 ⁄4" Width 91 ⁄ 2 " 1,223 * 2.8/7 841 * 2.6/6.4 595 585 2.2/5.4 536 506 2.1/5.2 371 301 1.7/4.3 252 193 1.5/3.5 154 119 1.5/3.5 108 85 1.5/3.5 85 67 1.5/3.5 63 51 1.5/3.5 117⁄ 8" 1,638 * 3.8/9.4 1,126 * 3.5/8.6 903 * 3.3/8.2 814 * 3.1/7.8 564 * 2.6/6.5 412 367 2.2/5.6 295 228 1.9/4.7 212 164 1.5/3.9 168 130 1.5/3.5 125 98 1.5/3.5 95 76 1.5/3.5 74 60 1.5/3.5 58 48 1.5/3.5 14" 1,961 * 4.5/11.3 1,389 * 4.3/10.6 1,114 * 4.1/10.2 1,045 * 4/10 767 * 3.5/8.9 562 * 3/7.6 402 367 2.6/6.4 318 264 2.3/5.7 271 211 2.1/5.3 206 160 1.8/4.5 158 124 1.5/3.8 123 98 1.5/3.5 98 78 1.5/3.5 78 64 1.5/3.5 51 ⁄ 2 " 948 916 1.5/3.5 307 * 1.5/3.5 154 * 1.5/3.5 124 * 1.5/3.5 57 * 1.5/3.5 31 ⁄ 2" Width (2-ply) 71 ⁄4" 91 ⁄ 2 " 1,755 2,446 * * 2/5 2.8/7 685 1,682 * * 1.5/3.5 2.6/6.4 349 1,190 1,171 * 1.5/3.5 2.2/5.4 284 1,073 1,013 * 1.5/3.5 2.1/5.2 135 742 602 * 1.5/3.5 1.7/4.3 70 505 386 * 1.5/3.5 1.5/3.5 308 238 1.5/3.5 217 170 1.5/3.5 171 135 1.5/3.5 126 102 1.5/3.5 95 79 1.5/3.5 73 62 1.5/3.5 56 50 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 14 117⁄ 8" 3,277 * 3.8/9.4 2,252 * 3.5/8.6 1,807 * 3.3/8.2 1,629 * 3.1/7.8 1,128 * 2.6/6.5 825 734 2.2/5.6 591 457 1.9/4.7 425 328 1.5/3.9 336 261 1.5/3.5 251 197 1.5/3.5 191 153 1.5/3.5 148 120 1.5/3.5 117 97 1.5/3.5 93 79 1.5/3.5 Snow Roof Load Tables General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 14 and General Assumptions on page 5. 2.0E Microllam® LVL: Roof—Snow Load Area 115% (PLF) continued Span 6' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 22' 24' 26' 28' 30' Condition Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) 14" 3,919 * 4.5/11.3 2,778 * 4.3/10.6 2,229 * 4.1/10.2 2,091 * 4/10 1,535 * 3.5/8.9 1,124 * 3/7.6 805 735 2.6/6.4 637 529 2.3/5.7 543 422 2.1/5.3 412 320 1.8/4.5 316 248 1.5/3.8 247 196 1.5/3.5 196 157 1.5/3.5 157 128 1.5/3.5 31 ⁄ 2" Width (2-ply) 16" 18" 3,919 3,919 * * 4.5/11.3 4.5/11.3 2,934 2,934 * * 4.5/11.3 4.5/11.3 2,468 2,468 * * 4.5/11.3 4.5/11.3 2,344 2,344 * * 4.5/11.3 4.5/11.3 1,950 1,950 * * 4.5/11.3 4.5/11.3 1,444 1,669 * * 3.9/9.7 4.5/11.3 1,035 1,291 * * 3.3/8.3 4.1/10.3 820 1,023 776 * 2.9/7.4 3.7/9.2 699 872 621 869 2.7/6.8 3.4/8.5 575 718 472 662 2.5/6.2 3.1/7.7 472 600 366 515 2.2/5.6 2.8/7.1 370 509 290 409 1.9/4.8 2.6/6.5 295 421 233 329 1.7/4.2 2.3/5.9 238 341 190 269 1.5/3.6 2.1/5.1 51 ⁄ 2 " 1,423 1,374 1.5/3.5 461 * 1.5/3.5 231 * 1.5/3.5 187 * 1.5/3.5 86 * 1.5/3.5 71 ⁄4" 2,632 * 2/5 1,028 * 1.5/3.5 524 * 1.5/3.5 427 * 1.5/3.5 203 * 1.5/3.5 106 * 1.5/3.5 91 ⁄ 2 " 3,669 * 2.8/7 2,524 * 2.6/6.4 1,785 1,757 2.2/5.4 1,610 1,520 2.1/5.2 1,113 904 1.7/4.3 757 579 1.5/3.5 463 358 1.5/3.5 326 256 1.5/3.5 256 203 1.5/3.5 190 153 1.5/3.5 143 118 1.5/3.5 110 93 1.5/3.5 85 75 1.5/3.5 66 61 1.5/3.5 51 ⁄4" Width (3-ply) 117⁄ 8" 14" 4,916 5,878 * * 3.8/9.4 4.5/11.3 3,378 4,168 * * 3.5/8.6 4.3/10.6 2,710 3,344 * * 3.3/8.2 4.1/10.2 2,444 3,137 * * 3.1/7.8 4/10 1,692 2,303 * * 2.6/6.5 3.5/8.9 1,238 1,686 1,102 * 2.2/5.6 3/7.6 886 1,208 686 1,103 1.9/4.7 2.6/6.4 638 956 492 794 1.5/3.9 2.3/5.7 504 815 392 633 1.5/3.5 2.1/5.3 377 619 296 480 1.5/3.5 1.8/4.5 287 475 229 372 1.5/3.5 1.5/3.8 223 371 181 294 1.5/3.5 1.5/3.5 175 294 145 236 1.5/3.5 1.5/3.5 139 236 118 193 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 15 16" 5,878 * 4.5/11.3 4,402 * 4.5/11.3 3,702 * 4.5/11.3 3,516 * 4.5/11.3 2,925 * 4.5/11.3 2,166 * 3.9/9.7 1,552 * 3.3/8.3 1,230 1,164 2.9/7.4 1,048 931 2.7/6.8 862 708 2.5/6.2 708 550 2.2/5.6 556 435 1.9/4.8 442 350 1.7/4.2 357 286 1.5/3.6 18" 5,878 * 4.5/11.3 4,402 * 4.5/11.3 3,702 * 4.5/11.3 3,516 * 4.5/11.3 2,925 * 4.5/11.3 2,503 * 4.5/11.3 1,936 * 4.1/10.3 1,535 * 3.7/9.2 1,309 1,304 3.4/8.5 1,077 994 3.1/7.7 900 773 2.8/7.1 763 613 2.6/6.5 632 494 2.3/5.9 511 404 2.1/5.1 Snow Roof Load Tables How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 17. 2.2E Parallam® PSL: Roof—Snow Load Area 115% (PLF) Span Condition Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 8' 91 ⁄4" 1,691 * 3.1/7.8 1,255 1,195 2.7/6.9 1,132 1,034 2.6/6.5 783 614 2.2/5.4 513 392 1.7/4.2 313 243 1.5/3.5 221 173 1.5/3.5 173 137 1.5/3.5 128 104 1.5/3.5 97 80 1.5/3.5 74 63 1.5/3.5 57 50 1.5/3.5 91 ⁄ 2 " 1,746 * 3.2/8 1,320 1,288 2.9/7.2 1,190 1,115 2.7/6.9 823 663 2.3/5.7 555 424 1.8/4.5 340 262 1.5/3.5 240 187 1.5/3.5 188 149 1.5/3.5 139 112 1.5/3.5 105 86 1.5/3.5 81 68 1.5/3.5 62 55 1.5/3.5 31⁄ 2" Width 111 ⁄4" 117⁄ 8" 14" 16" 18" 91 ⁄4" 2,142 2,291 2,441 2,441 2,441 2,537 * * * * * * 3.9/9.9 4.2/10.5 4.5/11.3 4.5/11.3 4.5/11.3 3.1/7.8 1,738 1,854 2,052 2,052 2,052 1,883 1,793 * * * * * 3.8/9.5 4.1/10.1 4.5/11.3 4.5/11.3 4.5/11.3 2.7/6.9 1,635 1,743 1,949 1,949 1,949 1,698 1,551 * * * * * 3.8/9.4 4/10 4.5/11.3 4.5/11.3 4.5/11.3 2.6/6.5 1,135 1,258 1,620 1,620 1,620 1,174 1,074 1,251 921 * * * 3.1/7.9 3.5/8.7 4.5/11.3 4.5/11.3 4.5/11.3 2.2/5.4 831 921 1,259 1,386 1,386 770 692 808 589 * * * 2.7/6.7 3/7.5 4.1/10.2 4.5/11.3 4.5/11.3 1.7/4.2 561 658 902 1,163 1,173 470 430 503 808 364 * * 2.2/5.4 2.5/6.3 3.5/8.7 4.5/11.1 4.5/11.3 1.5/3.5 399 468 714 922 1,044 332 308 361 582 854 260 * 1.7/4.3 2/5.1 3.1/7.7 4/9.9 4.5/11.3 1.5/3.5 315 370 604 786 964 260 245 287 464 683 956 206 1.5/3.7 1.8/4.4 2.8/7.1 3.7/9.2 4.5/11.3 1.5/3.5 235 276 454 646 810 192 185 217 352 519 728 156 1.5/3.5 1.5/3.6 2.4/5.9 3.3/8.4 4.2/10.4 1.5/3.5 179 211 348 520 677 145 143 168 273 403 567 120 1.5/3.5 1.5/3.5 2/5 3/7.4 3.8/9.6 1.5/3.5 138 164 272 408 574 111 113 132 215 319 450 95 1.5/3.5 1.5/3.5 1.7/4.3 2.5/6.3 3.5/8.8 1.5/3.5 108 129 216 325 464 86 90 106 173 257 362 76 1.5/3.5 1.5/3.5 1.5/3.7 2.2/5.5 3.1/7.7 1.5/3.5 86 102 173 262 375 67 74 86 141 209 296 62 1.5/3.5 1.5/3.5 1.5/3.5 1.9/4.8 2.7/6.8 1.5/3.5 69 82 140 213 307 53 61 71 117 173 245 51 1.5/3.5 1.5/3.5 1.5/3.5 1.7/4.2 2.4/6 1.5/3.5 91⁄ 2 " 2,619 * 3.2/8 1,980 1,932 2.9/7.2 1,786 1,672 2.7/6.9 1,235 994 2.3/5.7 833 637 1.8/4.5 510 394 1.5/3.5 360 281 1.5/3.5 282 223 1.5/3.5 209 168 1.5/3.5 158 130 1.5/3.5 121 102 1.5/3.5 94 82 1.5/3.5 74 67 1.5/3.5 58 55 1.5/3.5 51 ⁄4" Width 111 ⁄4" 117⁄ 8" 14" 16" 18" 3,213 3,436 3,661 3,661 3,661 * * * * * 3.9/9.9 4.2/10.5 4.5/11.3 4.5/11.3 4.5/11.3 2,607 2,781 3,079 3,079 3,079 * * * * * 3.8/9.5 4.1/10.1 4.5/11.3 4.5/11.3 4.5/11.3 2,453 2,615 2,923 2,923 2,923 * * * * * 3.8/9.4 4/10 4.5/11.3 4.5/11.3 4.5/11.3 1,703 1,887 2,431 2,431 2,431 1,611 1,876 * * * 3.1/7.9 3.5/8.7 4.5/11.3 4.5/11.3 4.5/11.3 1,246 1,381 1,889 2,079 2,079 1,038 1,212 * * * 2.7/6.7 3/7.5 4.1/10.2 4.5/11.3 4.5/11.3 842 987 1,353 1,745 1,760 645 755 1,213 * * 2.2/5.4 2.5/6.3 3.5/8.7 4.5/11.1 4.5/11.3 598 703 1,072 1,383 1,566 462 541 873 1,281 * 1.7/4.3 2/5.1 3.1/7.7 4/9.9 4.5/11.3 472 555 906 1,179 1,447 368 431 697 1,025 1,435 1.5/3.7 1.8/4.4 2.8/7.1 3.7/9.2 4.5/11.3 352 415 681 970 1,215 278 326 528 778 1,093 1.5/3.5 1.5/3.6 2.4/5.9 3.3/8.4 4.2/10.4 268 317 523 780 1,016 215 252 409 605 851 1.5/3.5 1.5/3.5 2/5 3/7.4 3.8/9.6 208 246 408 612 861 169 199 323 479 675 1.5/3.5 1.5/3.5 1.7/4.3 2.5/6.3 3.5/8.8 163 193 324 487 696 136 160 260 385 544 1.5/3.5 1.5/3.5 1.5/3.7 2.2/5.5 3.1/7.7 129 154 260 393 563 111 130 212 314 444 1.5/3.5 1.5/3.5 1.5/3.5 1.9/4.8 2.7/6.8 103 124 211 320 461 91 107 175 260 368 1.5/3.5 1.5/3.5 1.5/3.5 1.7/4.2 2.4/6 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 16 Snow Roof Load Tables General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 16 and General Assumptions on page 5. 2.2E Parallam® PSL: Roof—Snow Load Area 115% (PLF) continued Span Condition Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 91 ⁄4" 3,383 * 3.1/7.8 2,511 2,390 2.7/6.9 2,264 2,068 2.6/6.5 1,566 1,228 2.2/5.4 1,027 785 1.7/4.2 627 486 1.5/3.5 442 347 1.5/3.5 347 275 1.5/3.5 257 208 1.5/3.5 194 160 1.5/3.5 148 126 1.5/3.5 115 101 1.5/3.5 90 82 1.5/3.5 70 68 1.5/3.5 91⁄2" 3,492 * 3.2/8 2,641 2,576 2.9/7.2 2,381 2,230 2.7/6.9 1,647 1,326 2.3/5.7 1,111 849 1.8/4.5 680 525 1.5/3.5 480 375 1.5/3.5 377 298 1.5/3.5 279 225 1.5/3.5 211 173 1.5/3.5 162 137 1.5/3.5 125 110 1.5/3.5 98 89 1.5/3.5 77 73 1.5/3.5 111 ⁄4" 4,285 * 3.9/9.9 3,477 * 3.8/9.5 3,271 * 3.8/9.4 2,271 2,148 3.1/7.9 1,662 1,384 2.7/6.7 1,123 861 2.2/5.4 798 616 1.7/4.3 630 490 1.5/3.7 470 370 1.5/3.5 358 287 1.5/3.5 277 226 1.5/3.5 217 181 1.5/3.5 172 148 1.5/3.5 138 122 1.5/3.5 7" Width 117⁄ 8" 4,582 * 4.2/10.5 3,709 * 4.1/10.1 3,487 * 4/10 2,517 2,502 3.5/8.7 1,842 1,616 3/7.5 1,317 1,007 2.5/6.3 937 722 2/5.1 741 575 1.8/4.4 553 434 1.5/3.6 422 336 1.5/3.5 328 265 1.5/3.5 258 213 1.5/3.5 205 173 1.5/3.5 165 143 1.5/3.5 14" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,519 * 4.1/10.2 1,805 1,617 3.5/8.7 1,429 1,164 3.1/7.7 1,208 929 2.8/7.1 908 704 2.4/5.9 697 546 2/5 545 431 1.7/4.3 432 347 1.5/3.7 347 283 1.5/3.5 281 234 1.5/3.5 16" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,773 * 4.5/11.3 2,327 * 4.5/11.1 1,844 1,708 4/9.9 1,572 1,366 3.7/9.2 1,293 1,038 3.3/8.4 1,040 806 3/7.4 816 638 2.5/6.3 650 514 2.2/5.5 524 419 1.9/4.8 427 347 1.7/4.2 18" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,773 * 4.5/11.3 2,346 * 4.5/11.3 2,089 * 4.5/11.3 1,929 1,913 4.5/11.3 1,620 1,457 4.2/10.4 1,355 1,135 3.8/9.6 1,149 900 3.5/8.8 928 725 3.1/7.7 751 593 2.7/6.8 615 490 2.4/6 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 17 NON-SNOW ROOF LOAD TABLES How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 19. TimberStrand® LSL: Roof—Non-Snow Load Area 125% (PLF) Span 3' 4' 5' 6' 7' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 24' 28' 1.3E Grade Condition Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 31 ⁄ 2 " 4 3 ⁄8" 1,924 */1,420 1.5/3.5 1,080 977/651 1.5/3.5 647 521/347 1.5/3.5 317 309/206 1.5/3.5 171 */131 1.5/3.5 99 */89 1.5/3.5 51 ⁄ 2 " 2,978 */2,547 1.8/4.5 1,673 */1,215 1.5/3.5 1,068 993/662 1.5/3.5 614 595/397 1.5/3.5 336 */255 1.5/3.5 198 */173 1.5/3.5 98 */* 1.5/3.5 79 */* 1.5/3.5 Width 71 ⁄4" 5,047 */4,885 3.1/7.6 2,836 */2,476 2.3/5.7 1,812 */1,398 1.8/4.6 1,256 */857 1.5/3.8 742 */560 1.5/3.5 443 */384 1.5/3.5 224 */* 1.5/3.5 182 */* 1.5/3.5 85 */* 1.5/3.5 1.55E Grade 51 ⁄ 2 " 85 ⁄ 8" 7,032 */* 4.3/10.6 3,951 */3,764 3.2/8 2,526 */2,188 2.6/6.4 1,751 */1,367 2.1/5.3 1,284 */904 1.8/4.6 981 939/626 1.6/4 693 579/386 1.5/3.5 624 500/333 1.5/3.5 386 296/197 1.5/3.5 243 189/126 1.5/3.5 147 116/77 1.5/3.5 102 83/55 1.5/3.5 79 66/44 1.5/3.5 Plank Orientation 31 ⁄ 2 " 1,514 */1,224 1.5/3.5 1,084 820/546 1.5/3.5 533 431/287 1.5/3.5 258 253/169 1.5/3.5 138 */107 1.5/3.5 79 */72 1.5/3.5 91 ⁄ 2 " 3,959 */* 3.8/9.4 2,508 */* 3.2/8 1,835 */1,658 2.9/7.3 1,442 */1,048 2.8/6.9 1,058 1,049/699 2.4/5.9 809 731/487 2.1/5.2 572 453/302 1.7/4.4 515 392/261 1.7/4.1 306 233/155 1.5/3.5 194 149/99 1.5/3.5 118 92/61 1.5/3.5 83 66/44 1.5/3.5 64 52/35 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 18 13 ⁄4" Width 117⁄8" 4,717 */* 4.5/11.3 3,536 */* 4.5/11.3 2,507 */* 4/10 1,938 */1,831 3.7/9.3 1,579 */1,250 3.5/8.8 1,239 */886 3.2/7.9 877 840/560 2.7/6.7 791 731/487 2.5/6.3 547 440/293 2.1/5.3 373 284/189 1.7/4.2 230 177/118 1.5/3.5 163 127/84 1.5/3.5 128 101/67 1.5/3.5 72 59/39 1.5/3.5 14" 4,717 */* 4.5/11.3 3,536 */* 4.5/11.3 2,827 */* 4.5/11.3 2,354 */* 4.5/11.3 1,965 */1,877 4.4/11 1,643 */1,352 4.2/10.5 1,202 */870 3.6/9.1 1,084 */760 3.5/8.7 750 696/464 2.9/7.2 549 453/302 2.5/6.2 372 284/189 2/5 265 205/136 1.6/4 210 163/109 1.5/3.5 120 96/64 1.5/3.5 73 61/40 1.5/3.5 NON-SNOW ROOF LOAD TABLES General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. For door and window applications, Weyerhaeuser recommends using the L/360 value for a live load deflection limit and the L/240 value for a total load limit. Also see How to Use This Table on page 18 and General Assumptions on page 5. TimberStrand® LSL: Roof—Non-Snow Load Area 125% (PLF) continued Span 3' 4' 5' 6' 7' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 24' 28' Condition Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 1.55E Grade 31 ⁄ 2 " 91 ⁄ 2 " 117⁄8" 7,918 9,432 */* */* 3.8/9.4 4.5/11.3 5,017 7,070 */* */* 3.2/8 4.5/11.3 3,670 5,015 */3,316 */* 2.9/7.3 4/10 2,884 3,876 */2,097 */3,662 2.8/6.9 3.7/9.3 2,116 3,158 2,098/1,399 */2,501 2.4/5.9 3.5/8.8 1,618 2,479 1,462/974 */1,773 2.1/5.2 3.2/7.9 1,144 1,754 907/605 1,681/1,121 1.7/4.4 2.7/6.7 1,031 1,582 785/523 1,462/974 1.7/4.1 2.5/6.3 612 1,094 467/311 881/587 1.5/3.5 2.1/5.3 388 746 299/199 569/379 1.5/3.5 1.7/4.2 236 460 185/123 354/236 1.5/3.5 1.5/3.5 166 326 132/88 254/169 1.5/3.5 1.5/3.5 129 257 105/70 202/135 1.5/3.5 1.5/3.5 71 145 61/40 118/79 1.5/3.5 1.5/3.5 87 75/50 1.5/3.5 Width 14" 9,432 */* 4.5/11.3 7,070 */* 4.5/11.3 5,652 */* 4.5/11.3 4,707 */* 4.5/11.3 3,930 */3,755 4.4/11 3,286 */2,705 4.2/10.5 2,404 */1,740 3.6/9.1 2,168 */1,520 3.5/8.7 1,501 1,393/928 2.9/7.2 1,098 907/605 2.5/6.2 744 569/379 2/5 531 410/273 1.6/4 421 327/218 1.5/3.5 241 192/128 1.5/3.5 147 122/81 1.5/3.5 51 ⁄4" Width (2- or 3-ply) 16" 91 ⁄ 2 " 117⁄8" 14" 16" 9,432 11,877 14,148 14,148 14,148 */* */* */* */* */* 4.5/11.3 3.8/9.4 4.5/11.3 4.5/11.3 4.5/11.3 7,070 7,526 10,605 10,605 10,605 */* */* */* */* */* 4.5/11.3 3.2/8 4.5/11.3 4.5/11.3 4.5/11.3 5,652 5,506 7,522 8,478 8,478 */* */4,975 */* */* */* 4.5/11.3 2.9/7.3 4/10 4.5/11.3 4.5/11.3 4,707 4,326 5,814 7,061 7,061 */* */3,146 */5,493 */* */* 4.5/11.3 2.8/6.9 3.7/9.3 4.5/11.3 4.5/11.3 4,032 3,174 4,737 5,895 6,048 3,148/2,098 */3,752 */* */5,633 */* 4.5/11.3 2.4/5.9 3.5/8.8 4.4/11 4.5/11.3 3,526 2,427 3,719 4,930 5,289 2,193/1,462 */2,660 */* */4,058 */* 4.5/11.3 2.1/5.2 3.2/7.9 4.2/10.5 4.5/11.3 2,966 1,716 2,631 3,606 4,450 1,361/907 2,522/1,681 */2,610 */2,456 */3,684 4.5/11.3 1.7/4.4 2.7/6.7 3.6/9.1 4.5/11.3 2,800 1,547 2,373 3,253 4,200 1,178/785 2,193/1,462 */2,280 */2,154 */3,232 4.5/11.2 1.7/4.1 2.5/6.3 3.5/8.7 4.5/11.2 1,939 918 1,642 2,252 2,908 700/467 1,322/881 2,089/1,393 */2,001 */1,334 3.7/9.3 1.5/3.5 2.1/5.3 2.9/7.2 3.7/9.3 1,420 582 1,119 1,648 2,130 1,316/877 448/299 854/569 1,361/907 1,974/1,316 3.2/8 1.5/3.5 1.7/4.2 2.5/6.2 3.2/8 1,017 354 690 1,116 1,526 832/555 277/185 532/354 854/569 1,248/832 2.7/6.8 1.5/3.5 1.5/3.5 2/5 2.7/6.8 785 249 489 797 1,177 601/401 198/132 381/254 615/410 902/601 2.4/5.9 1.5/3.5 1.5/3.5 1.6/4 2.4/5.9 624 194 385 631 936 481/320 157/105 304/202 491/327 722/481 2/5.1 1.5/3.5 1.5/3.5 1.5/3.5 2/5.1 361 106 217 361 542 284/189 91/61 177/118 288/192 426/284 1.5/3.6 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.6 224 61 130 221 336 181/120 58/38 112/75 183/122 271/181 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 19 NON-SNOW ROOF LOAD TABLES How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 21. 2.0E Microllam® LVL: Roof—Non-Snow Load Area 125% (PLF) Span 6' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 22' 24' 26' 28' 30' Condition Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) 51 ⁄ 2 " 474 458 1.5/3.5 153 * 1.5/3.5 77 * 1.5/3.5 62 * 1.5/3.5 71 ⁄4" 954 * 2.2/5.5 342 * 1.5/3.5 174 * 1.5/3.5 142 * 1.5/3.5 67 * 1.5/3.5 13 ⁄4" Width 91 ⁄ 2 " 1,329 * 3.1/7.6 915 * 2.8/7 647 585 2.4/5.9 583 506 2.2/5.6 397 301 1.8/4.6 252 193 1.5/3.5 154 119 1.5/3.5 108 85 1.5/3.5 85 67 1.5/3.5 63 51 1.5/3.5 117⁄8" 1,781 * 4.1/10.2 1,224 * 3.8/9.4 982 * 3.6/8.9 886 * 3.4/8.5 613 568 2.8/7.1 449 367 2.4/6.1 299 228 1.9/4.8 212 164 1.5/3.9 168 130 1.5/3.5 125 98 1.5/3.5 95 76 1.5/3.5 74 60 1.5/3.5 58 48 1.5/3.5 Total Load Deflection L/240 Min. End/Int. Bearing (in.) 14" 1,961 * 4.5/11.3 1,469 * 4.5/11.3 1,212 * 4.4/11 1,137 * 4.4/10.9 835 * 3.9/9.6 611 585 3.3/8.3 438 367 2.8/7 345 264 2.5/6.2 274 211 2.1/5.4 206 160 1.8/4.5 158 124 1.5/3.8 123 98 1.5/3.5 98 78 1.5/3.5 78 64 1.5/3.5 51 ⁄ 2 " 948 916 1.5/3.5 307 * 1.5/3.5 154 * 1.5/3.5 124 * 1.5/3.5 57 * 1.5/3.5 31 ⁄ 2" Width (2 ply) 71 ⁄4" 91 ⁄ 2 " 1,908 2,659 * * 2.2/5.5 3.1/7.6 685 1,830 * * 1.5/3.5 2.8/7 349 1,294 1,171 * 1.5/3.5 2.4/5.9 284 1,167 1,013 * 1.5/3.5 2.2/5.6 135 794 602 * 1.5/3.5 1.8/4.6 70 505 386 * 1.5/3.5 1.5/3.5 308 238 1.5/3.5 217 170 1.5/3.5 171 135 1.5/3.5 126 102 1.5/3.5 95 79 1.5/3.5 73 62 1.5/3.5 56 50 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 20 117⁄8" 3,563 * 4.1/10.2 2,449 * 3.8/9.4 1,965 * 3.6/8.9 1,772 * 3.4/8.5 1,227 1,137 2.8/7.1 898 734 2.4/6.1 598 457 1.9/4.8 425 328 1.5/3.9 336 261 1.5/3.5 251 197 1.5/3.5 191 153 1.5/3.5 148 120 1.5/3.5 117 97 1.5/3.5 93 79 1.5/3.5 NON-SNOW ROOF LOAD TABLES General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 20 and General Assumptions on page 5. 2.0E Microllam® LVL: Roof—Non-Snow Load Area 125% (PLF) continued Span 6' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 22' 24' 26' 28' 30' Condition Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) Total Load Deflection L/240 Min. End/Int. Bearing (in.) 14" 3,919 * 4.5/11.3 2,934 * 4.5/11.3 2,425 * 4.4/11 2,275 * 4.4/10.9 1,670 * 3.9/9.6 1,223 1,171 3.3/8.3 876 735 2.8/7 691 529 2.5/6.2 549 422 2.1/5.4 412 320 1.8/4.5 316 248 1.5/3.8 247 196 1.5/3.5 196 157 1.5/3.5 157 128 1.5/3.5 31 ⁄ 2" Width (2-ply) 16" 18" 3,919 3,919 * * 4.5/11.3 4.5/11.3 2,934 2,934 * * 4.5/11.3 4.5/11.3 2,468 2,468 * * 4.5/11.3 4.5/11.3 2,344 2,344 * * 4.5/11.3 4.5/11.3 1,950 1,950 * * 4.5/11.3 4.5/11.3 1,571 1,669 * * 4.2/10.6 4.5/11.3 1,126 1,405 1,074 * 3.6/9 4.5/11.2 892 1,113 776 1,084 3.2/8 4/10 761 950 621 869 3/7.4 3.7/9.2 613 782 472 662 2.6/6.6 3.4/8.4 472 654 366 515 2.2/5.6 3.1/7.7 370 527 290 409 1.9/4.8 2.7/6.8 295 421 233 329 1.7/4.2 2.3/5.9 238 341 190 269 1.5/3.6 2.1/5.1 51 ⁄ 2 " 1,423 1,374 1.5/3.5 461 * 1.5/3.5 231 * 1.5/3.5 187 * 1.5/3.5 86 * 1.5/3.5 71 ⁄4" 2,862 * 2.2/5.5 1,028 * 1.5/3.5 524 * 1.5/3.5 427 * 1.5/3.5 203 * 1.5/3.5 106 * 1.5/3.5 91 ⁄ 2 " 3,989 * 3.1/7.6 2,745 * 2.8/7 1,942 1,757 2.4/5.9 1,751 1,520 2.2/5.6 1,191 904 1.8/4.6 757 579 1.5/3.5 463 358 1.5/3.5 326 256 1.5/3.5 256 203 1.5/3.5 190 153 1.5/3.5 143 118 1.5/3.5 110 93 1.5/3.5 85 75 1.5/3.5 66 61 1.5/3.5 51 ⁄4" Width (3-ply) 117⁄8" 14" 5,345 5,878 * * 4.1/10.2 4.5/11.3 3,673 4,402 * * 3.8/9.4 4.5/11.3 2,948 3,637 * * 3.6/8.9 4.4/11 2,659 3,412 * * 3.4/8.5 4.4/10.9 1,841 2,505 1,706 * 2.8/7.1 3.9/9.6 1,347 1,835 1,102 1,757 2.4/6.1 3.3/8.3 897 1,315 686 1,103 1.9/4.8 2.8/7 638 1,037 492 794 1.5/3.9 2.5/6.2 504 823 392 633 1.5/3.5 2.1/5.4 377 619 296 480 1.5/3.5 1.8/4.5 287 475 229 372 1.5/3.5 1.5/3.8 223 371 181 294 1.5/3.5 1.5/3.5 175 294 145 236 1.5/3.5 1.5/3.5 139 236 118 193 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 21 16" 5,878 * 4.5/11.3 4,402 * 4.5/11.3 3,702 * 4.5/11.3 3,516 * 4.5/11.3 2,925 * 4.5/11.3 2,356 * 4.2/10.6 1,689 1,611 3.6/9 1,339 1,164 3.2/8 1,142 931 3/7.4 919 708 2.6/6.6 708 550 2.2/5.6 556 435 1.9/4.8 442 350 1.7/4.2 357 286 1.5/3.6 18" 5,878 * 4.5/11.3 4,402 * 4.5/11.3 3,702 * 4.5/11.3 3,516 * 4.5/11.3 2,925 * 4.5/11.3 2,503 * 4.5/11.3 2,107 * 4.5/11.2 1,670 1,626 4/10 1,425 1,304 3.7/9.2 1,173 994 3.4/8.4 981 773 3.1/7.7 790 613 2.7/6.8 632 494 2.3/5.9 511 404 2.1/5.1 NON-SNOW ROOF LOAD TABLES How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 23. 2.2E Parallam® PSL: Roof—Non-Snow Load Area 125% (PLF) Span Condition Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 91 ⁄4" 1,839 * 3.4/8.5 1,365 1,195 3/7.5 1,231 1,034 2.8/7.1 808 614 2.2/5.6 513 392 1.7/4.2 313 243 1.5/3.5 221 173 1.5/3.5 173 137 1.5/3.5 128 104 1.5/3.5 97 80 1.5/3.5 74 63 1.5/3.5 57 50 1.5/3.5 91 ⁄ 2 " 1,899 * 3.5/8.7 1,436 1,288 3.1/7.9 1,295 1,115 3/7.5 873 663 2.4/6.1 555 424 1.8/4.5 340 262 1.5/3.5 240 187 1.5/3.5 188 149 1.5/3.5 139 112 1.5/3.5 105 86 1.5/3.5 81 68 1.5/3.5 62 55 1.5/3.5 111 ⁄4" 2,330 * 4.3/10.7 1,890 * 4.1/10.3 1,778 * 4.1/10.2 1,235 1,074 3.4/8.6 904 692 2.9/7.3 561 430 2.2/5.4 399 308 1.7/4.3 315 245 1.5/3.7 235 185 1.5/3.5 179 143 1.5/3.5 138 113 1.5/3.5 108 90 1.5/3.5 86 74 1.5/3.5 69 61 1.5/3.5 31 ⁄ 2" Width 117⁄ 8" 14" 2,441 2,441 * * 4.5/11.3 4.5/11.3 2,017 2,052 * * 4.4/11 4.5/11.3 1,896 1,949 * * 4.4/10.9 4.5/11.3 1,369 1,620 1,251 * 3.8/9.5 4.5/11.3 1,002 1,370 808 1,288 3.2/8.1 4.4/11.1 658 982 503 808 2.5/6.3 3.8/9.4 468 761 361 582 2/5.1 3.3/8.2 370 604 287 464 1.8/4.4 2.8/7.1 276 454 217 352 1.5/3.6 2.4/5.9 211 348 168 273 1.5/3.5 2/5 164 272 132 215 1.5/3.5 1.7/4.3 129 216 106 173 1.5/3.5 1.5/3.7 102 173 86 141 1.5/3.5 1.5/3.5 82 140 71 117 1.5/3.5 1.5/3.5 16" 2,441 * 4.5/11.3 2,052 * 4.5/11.3 1,949 * 4.5/11.3 1,620 * 4.5/11.3 1,386 * 4.5/11.3 1,173 * 4.5/11.3 1,003 854 4.3/10.8 856 683 4/10 674 519 3.5/8.7 520 403 3/7.4 408 319 2.5/6.3 325 257 2.2/5.5 262 209 1.9/4.8 213 173 1.7/4.2 18" 2,441 * 4.5/11.3 2,052 * 4.5/11.3 1,949 * 4.5/11.3 1,620 * 4.5/11.3 1,386 * 4.5/11.3 1,173 * 4.5/11.3 1,044 * 4.5/11.3 964 956 4.5/11.3 875 728 4.5/11.3 736 567 4.2/10.4 580 450 3.6/8.9 464 362 3.1/7.7 375 296 2.7/6.8 307 245 2.4/6 91 ⁄4" 2,759 * 3.4/8.5 2,048 1,793 3/7.5 1,847 1,551 2.8/7.1 1,213 921 2.2/5.6 770 589 1.7/4.2 470 364 1.5/3.5 332 260 1.5/3.5 260 206 1.5/3.5 192 156 1.5/3.5 145 120 1.5/3.5 111 95 1.5/3.5 86 76 1.5/3.5 67 62 1.5/3.5 53 51 1.5/3.5 91 ⁄ 2 " 2,848 * 3.5/8.7 2,154 1,932 3.1/7.9 1,942 1,672 3/7.5 1,310 994 2.4/6.1 833 637 1.8/4.5 510 394 1.5/3.5 360 281 1.5/3.5 282 223 1.5/3.5 209 168 1.5/3.5 158 130 1.5/3.5 121 102 1.5/3.5 94 82 1.5/3.5 74 67 1.5/3.5 58 55 1.5/3.5 111 ⁄4" 3,495 * 4.3/10.7 2,836 * 4.1/10.3 2,668 * 4.1/10.2 1,853 1,611 3.4/8.6 1,356 1,038 2.9/7.3 842 645 2.2/5.4 598 462 1.7/4.3 472 368 1.5/3.7 352 278 1.5/3.5 268 215 1.5/3.5 208 169 1.5/3.5 163 136 1.5/3.5 129 111 1.5/3.5 103 91 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 22 51 ⁄4" Width 117⁄ 8" 3,661 * 4.5/11.3 3,025 * 4.4/11 2,844 * 4.4/10.9 2,053 1,876 3.8/9.5 1,503 1,212 3.2/8.1 987 755 2.5/6.3 703 541 2/5.1 555 431 1.8/4.4 415 326 1.5/3.6 317 252 1.5/3.5 246 199 1.5/3.5 193 160 1.5/3.5 154 130 1.5/3.5 124 107 1.5/3.5 14" 3,661 * 4.5/11.3 3,079 * 4.5/11.3 2,923 * 4.5/11.3 2,431 * 4.5/11.3 2,055 1,932 4.4/11.1 1,473 1,213 3.8/9.4 1,141 873 3.3/8.2 906 697 2.8/7.1 681 528 2.4/5.9 523 409 2/5 408 323 1.7/4.3 324 260 1.5/3.7 260 212 1.5/3.5 211 175 1.5/3.5 16" 3,661 * 4.5/11.3 3,079 * 4.5/11.3 2,923 * 4.5/11.3 2,431 * 4.5/11.3 2,079 * 4.5/11.3 1,760 * 4.5/11.3 1,505 1,281 4.3/10.8 1,284 1,025 4/10 1,012 778 3.5/8.7 780 605 3/7.4 612 479 2.5/6.3 487 385 2.2/5.5 393 314 1.9/4.8 320 260 1.7/4.2 18" 3,661 * 4.5/11.3 3,079 * 4.5/11.3 2,923 * 4.5/11.3 2,431 * 4.5/11.3 2,079 * 4.5/11.3 1,760 * 4.5/11.3 1,566 * 4.5/11.3 1,447 1,435 4.5/11.3 1,312 1,093 4.5/11.3 1,105 851 4.2/10.4 870 675 3.6/8.9 696 544 3.1/7.7 563 444 2.7/6.8 461 368 2.4/6 NON-SNOW ROOF LOAD TABLES General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 22 and General Assumptions on page 5. 2.2E Parallam® PSL: Roof—Non-Snow Load Area 125% (PLF) continued Span Condition Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 91 ⁄4" 3,679 * 3.4/8.5 2,731 2,390 3/7.5 2,462 2,068 2.8/7.1 1,617 1,228 2.2/5.6 1,027 785 1.7/4.2 627 486 1.5/3.5 442 347 1.5/3.5 347 275 1.5/3.5 257 208 1.5/3.5 194 160 1.5/3.5 148 126 1.5/3.5 115 101 1.5/3.5 90 82 1.5/3.5 70 68 1.5/3.5 91 ⁄ 2 " 3,798 * 3.5/8.7 2,872 2,576 3.1/7.9 2,590 2,230 3/7.5 1,747 1,326 2.4/6.1 1,111 849 1.8/4.5 680 525 1.5/3.5 480 375 1.5/3.5 377 298 1.5/3.5 279 225 1.5/3.5 211 173 1.5/3.5 162 137 1.5/3.5 125 110 1.5/3.5 98 89 1.5/3.5 77 73 1.5/3.5 111 ⁄4" 4,660 * 4.3/10.7 3,781 * 4.1/10.3 3,557 * 4.1/10.2 2,471 2,148 3.4/8.6 1,809 1,384 2.9/7.3 1,123 861 2.2/5.4 798 616 1.7/4.3 630 490 1.5/3.7 470 370 1.5/3.5 358 287 1.5/3.5 277 226 1.5/3.5 217 181 1.5/3.5 172 148 1.5/3.5 138 122 1.5/3.5 7" Width 117⁄ 8" 4,882 * 4.5/11.3 4,034 * 4.4/11 3,792 * 4.4/10.9 2,738 2,502 3.8/9.5 2,004 1,616 3.2/8.1 1,317 1,007 2.5/6.3 937 722 2/5.1 741 575 1.8/4.4 553 434 1.5/3.6 422 336 1.5/3.5 328 265 1.5/3.5 258 213 1.5/3.5 205 173 1.5/3.5 165 143 1.5/3.5 14" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,740 2,576 4.4/11.1 1,964 1,617 3.8/9.4 1,522 1,164 3.3/8.2 1,208 929 2.8/7.1 908 704 2.4/5.9 697 546 2/5 545 431 1.7/4.3 432 347 1.5/3.7 347 283 1.5/3.5 281 234 1.5/3.5 16" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,773 * 4.5/11.3 2,346 * 4.5/11.3 2,007 1,708 4.3/10.8 1,712 1,366 4/10 1,349 1,038 3.5/8.7 1,040 806 3/7.4 816 638 2.5/6.3 650 514 2.2/5.5 524 419 1.9/4.8 427 347 1.7/4.2 18" 4,882 * 4.5/11.3 4,105 * 4.5/11.3 3,898 * 4.5/11.3 3,241 * 4.5/11.3 2,773 * 4.5/11.3 2,346 * 4.5/11.3 2,089 * 4.5/11.3 1,929 1,913 4.5/11.3 1,750 1,457 4.5/11.3 1,473 1,135 4.2/10.4 1,160 900 3.6/8.9 928 725 3.1/7.7 751 593 2.7/6.8 615 490 2.4/6 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 23 BEAM DETAILS Bearing at Wall Beam to Beam Connection Bearing for Door or Window Header 11⁄8" TJ® Rim Board or 1¼" TimberStrand® LSL blocking for lateral support Strap per code if top plate is not continuous over header Strap per code if top plate is not continuous over column Top mount hanger Face mount hanger Column L2 L1 Bearing at Concrete Wall L3 Bearing at Column Beam to Column Lateral Brace TJI® joist Floor beam Strap Steel column L4 Protect untreated wood from direct contact with concrete L5 Verify beam bearing length on page 26 and column capacity on page 30 L14 Suggested lateral bracing detail for beams when required. Verify beam bearing length on page 26. WINDOW AND DOOR HEADER DETAILS 2x4 Wall Framing High Header Low Header Full Depth Header Header Header Header L8 L7 L9 2x_ nailer* *Double nailer may be required depending upon the opening size and window type 2x6 Wall Framing Headers not matching wall thickness may be installed flush to the inside or outside of the wall, depending upon sheathing and trim attachment requirements Plank Orientation Header Low Header High Header Double top plate 2x6 wall framing L10 31⁄2" x 51⁄2" TimberStrand® LSL in plank orientation 31⁄2"-wide header L11 31⁄2"-wide header 2x_ framing at opening L12 *Double nailer may be required depending upon the opening size and window type Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 24 2x_ nailer* Window and Door Header Details Dropped Header with Full Lateral Bracing Framing above must be sheathed to provide lateral stability to the top of the beam Main structural header. See pages 28 and 29 for connecting multiple plies. One 8d (0.113" x 21/2") nail each side of joist or blocking. Blocking is required if joist framing is parallel to beam. Joist spacing must be 24" on-center or less. Low header Nail continuous king studs to the end of the beam using: – Four 10d (0.131" x 3") nails for beams 117⁄8" deep or less – Six 10d (0.131" x 3") nails for beams 18" deep or less L15 Fasten 2x_ plate to low header with 10d (0.131" x 3") nails at 8" on-center, staggered Continuous king stud Dropped Header with Acceptable Lateral Bracing 4'-0" maximum height cripple wall. Wall studs at 24" on-center, maximum. One 8d (0.113" x 2½") nail each side of joist or blocking. Blocking is required if joist framing is parallel to beam. Joist spacing must be 24" on-center or less. Fasten 2x_ plate to header below with 10d (0.131" x 3") nails at 8" on-center, staggered Sheathing strength axis See pages 28 and 29 for connecting multiple plies Nail continuous king studs to the end of the beam using: – Four 10d (0.131" x 3") nails for beams 117⁄8" deep or less – Six 10d (0.131" x 3") nails for beams 16" deep or less L16 Rated wall sheathing (7⁄16" nominal) continuous from bottom of beam to top of wall. Fasten sheathing with 8d (0.113" x 21/2") nails at 6" on-center at panel edges and 12" on-center in panel field. Continuous king stud When framed as shown above, the following dropped headers are considered fully braced under uniform-load, simple-span conditions: Single-ply: – 1¾" wide headers, 117⁄8" deep or less – 3½" wide headers, 16" deep or less, with a maximum span of 18'-6" Multiple-ply: – Headers up to four 1¾" plies, 117⁄8" deep or less – Headers up to four 1¾" x 14" plies, with a maximum span of 8'-6" NAILING ON NARROW FACE Nails Installed on the Narrow Face Nail Size 8d (0.131" x 2½") or 10d (0.128" x 3") 10d (0.148" x 3") or 12d (0.148" x 3¼") 16d (0.162" x 3½") ■ Closest On-Center Spacing Per Row 3½" 1¾" Microllam ® LVL TimberStrand ® LSL TimberStrand ® LSL Parallam ® PSL 3" 3" 4" 4" 4" 3" 5" 4" 6" 3½" 8" 6" If more than one row of nails is used, the rows must be offset at least ½" and staggered. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 25 ALLOWABLE HOLES 1.55E TimberStrand® LSL Headers and Beams General Notes 2 x diameter of the largest hole (minimum) 1⁄ 3 ■ Allowed hole zone depth Allowed hole zone suitable for headers and beams with uniform and/or concentrated loads anywhere along the member. ■ Round holes only. ■ No holes in headers or beams in plank orientation. 1.55E TimberStrand® LSL 8" Header or Beam Depth 9½" 117⁄ 8" 14"–16" 8" ■ Other Trus Joist® Headers and Beams 1.3E TimberStrand® hole zone LSL Microllam® LVL and Parallam® PSL hole zone See illustration for allowed hole zone. General Notes ■ 2 x diameter of the largest hole (minimum) 1⁄ 3 depth d 1.3E TimberStrand® LSL allowed hole zone Allowed hole zone suitable for headers and beams with uniform loads only. ■ Round holes only. ■ No holes in cantilevers. ■ No holes in headers or beams in plank orientation. Other Trus Joist® Beams Microllam® LVL and Parallam® PSL allowed hole zone middle 1⁄3 span d Maximum Round Hole Size 3" 35 ⁄ 8 " 45 ⁄ 8" Header or Beam Depth 4 3⁄ 8" 5½" 7¼"–18" d ■ Maximum Round Hole Size 1" 1¾" 2" See illustration for allowed hole zone. Larger holes in Trus Joist ® structural composite lumber may be possible; refer to Forte ® or Javelin ® software. DO NOT cut, notch, or drill holes in headers or beams except as indicated in the illustrations and tables WARNING: Drilling, sawing, sanding or machining wood products generates wood dust. The paint and/or coatings on this product may contain titanium dioxide. Wood dust and titanium dioxide are substances known to the State of California to cause cancer. For more information on Proposition 65, visit wy.com/inform. BEARING LENGTH REQUIREMENTS Reaction (lbs) 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 1.3E TimberStrand ® LSL Beam Orientation Plank Orientation Width Width 3½" 5½" 1½" 11/2" 13/4" 11/2" 21/2" 13/4" 31/4" 21/2" 41/4" 3" 5" 31/2" 53/4" 41/4" 61/2" 43/4" 71/4" 51/4" 53/4" 61/2" 7" 71/2" 1.55E TimberStrand ® LSL Beam Orientation Width 1¾" 3½" 5¼" 1½" 11/2" 11/2" 23/4" 11/2" 11/2" 4" 2" 11/2" 51/4" 23/4" 13/4" 6½" 31/4" 21/4" 73/4" 4" 23/4" 41/2" 3" 51/4" 31/2" 53/4" 4" 6½" 41/4" 7" 43/4" 7¾" 51/4" 53/4" 6" 61/2" 2.0E Microllam ® LVL Beam Orientation Width 1¾" 3½" 5¼" 1¾" 11/2" 11/2" 3¼" 13 ⁄4" 11/2" 4¾" 21/2" 1¾" 6¼" 31/4" 2¼" 7¾" 4" 2¾" 4¾" 3¼" 51/2" 3¾" 61/4" 41/4" 7" 4¾" 7¾" 51/4" 5¾" 61/4" 6¾" 71/4" 7¾" 2.2E Parallam ® PSL Beam Orientation Width 3½" 5¼" 7" 11/2" 11/2" 11/2" 2" 11/2" 11/2" 23/4" 2" 11/2" 33/4" 21/2" 2" 43/4" 31/4" 21/2" 51/2" 33/4" 23/4" 61/2" 41/2" 31/4" 71/2" 5" 33/4" 51/2" 41/4" 61/4" 43/4" 63/4" 51/4" 71/2" 51/2" 6" 61/2" 7" General Notes ■ Minimum bearing length: 11⁄2" at ends, 31⁄2" at intermediate supports. ■ Bearing across full beam width is required. ■ Interpolation between reaction loads is permitted for determining bearing lengths. ■ Bearing lengths based on the following bearing stresses: – 1.3E TimberStrand ® LSL: 710 psi; 635 psi for plank orientation. – 1.55E TimberStrand ® LSL: 900 psi. – 2.0E Microllam ® LVL: 750 psi. –2.2E Parallam ® PSL: 625 psi. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 26 Tapered End Cuts Allowable Reactions for 31⁄2"(1) TimberStrand® LSL Headers and Beams (lbs) Bearing 31⁄2" Wood Plate (2) 51⁄4" Wood Plate (2) 31⁄2" Column(3) Beam Depth 71/4" 85 ⁄8" 91/2" 117⁄ 8" 14" 16" 71/4" 8 5 ⁄8" 91/2" 117⁄ 8" 14" 16" 71/4" 8 5 ⁄8" 91/2" 117⁄ 8" 14" 16" 41⁄2" 5,205 5,205 4,860 4,860 5" 5,205 5,205 5,205 5,205 5,205 51⁄2" 5,205 5,205 5,205 5,205 5,205 7,190 7,205 5,255 5,255 5,255 7,190 7,810 5,710 5,710 5,710 6,665 6,665 4,860 4,860 7,190 7,285 5,310 5,310 5,310 7,190 7,810 6,160 6,160 6,160 6,160 7,190 7,900 5,765 5,765 5,765 Outside Heel Height D1 6" 61⁄2" 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 7,810 6,610 6,610 6,610 6,610 7,190 8,520 6,215 6,215 6,215 6,215 7" 71⁄2" 8" 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 7,810 6,870 7,065 7,065 7,065 7,810 6,870 7,515 7,515 7,515 6,870 7,810 7,810 7,810 6,870 7,810 7,810 7,810 8,555 6,670 6,670 6,670 6,670 8,555 6,870 7,120 7,120 7,120 8,555 6,870 7,570 7,570 7,570 6,870 8,025 8,025 8,025 General Notes No increase for duration of load is permitted. ■ ■ ■ No holes or concentrated load within tapered cut. Table considers only downward loading. Contact your Weyerhaeuser representative for assistance with uplift loading or other conditions. Minimum 3:12 slope Sloped end cut Beam depth D1 (1) For 13⁄4" and 51⁄4" beams, multiply by 0.5 and 1.5, respectively. (2) Bearing lengths, based on Fc⊥ of 425 psi. (3) Bearing lengths based on Fc⊥ of 710 psi for 1.3E TimberStrand® LSL and 900 psi for 1.55E TimberStrand® LSL. Tapered end cut detailed above is not allowed with TJI® joists Allowable Reactions for 31⁄2"(1) Microllam® LVL and Parallam® PSL Beams (lbs) Bearing 31 ⁄ 2 " Wood Plate (2) 51⁄4" Wood Plate (2) 31 ⁄ 2 " Column(3) Beam Depth 71⁄4" 91⁄4" 91 ⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 18" 71⁄4" 91⁄4" 91 ⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 18" 71⁄4" 91⁄4" 91 ⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 18" 41 ⁄ 2" 4,470 4,470 4,470 4,470 4,470 5" 4,820 4,885 4,885 4,885 4,885 4,885 51 ⁄ 2 " 4,820 5,205 5,205 5,205 5,205 5,205 4,820 4,830 4,830 4,830 4,830 4,830 4,820 5,245 5,245 5,245 5,245 5,245 4,820 5,665 5,665 5,665 5,665 5,665 5,665 4,470 4,470 4,470 4,470 4,470 4,820 4,885 4,885 4,885 4,885 4,885 4,820 5,300 5,300 5,300 5,300 5,300 Outside Heel Height D1 6" 61 ⁄ 2 " 7" 4,820 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 6,080 6,080 6,080 6,080 6,080 6,080 6,080 4,820 5,715 5,715 5,715 5,715 5,715 5,715 Wood Plate Connection 71 ⁄ 2 " 8" 10" 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 6,150 6,320 6,495 6,495 6,495 6,495 6,495 6,150 6,320 6,910 6,910 6,910 6,910 6,910 6,150 6,320 7,325 7,325 7,325 7,325 7,325 6,320 7,480 7,740 7,740 7,740 7,740 7,810 7,810 7,810 7,810 6,130 6,130 6,130 6,130 6,130 6,130 6,130 6,150 6,320 6,545 6,545 6,545 6,545 6,545 6,150 6,320 6,960 6,960 6,960 6,960 6,960 6,150 6,320 7,375 7,375 7,375 7,375 7,375 7,480 7,655 7,655 7,655 7,655 Sloped end cut Beam depth D1 Wood plate Column Connection Sloped end cut Beam depth D1 Column (1) For 13⁄4", 51⁄4", and 7" beams, multiply by 0.5, 1.5, and 2.0, respectively. (2) Bearing lengths based on Fc⊥ of 425 psi. (3) Bearing lengths based on Fc⊥ of 625 psi. DO NOT overhang seat cuts on beams beyond inside face of support member Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 27 MULTIPLE-MEMBER CONNECTIONS FOR SIDE-LOADED BEAMS L17 Uniform Load—Maximum Uniform Load Applied to Either Outside Member (PLF) Fastener Pattern Assembly A Fastener Type 10d (0.128" x 3") Nail(1) ½" A307 Through Bolt (2)(3) SDS (3) USP WS (3) TrussLOK-EWP ™(3) SDW22(3)(4) Assembly B Assembly C Assembly E 2" 2" 2" 2" Fastener 13⁄4" 13⁄4" 13⁄4" 31⁄2" Number On-Center Location of Rows Spacing 3½" wide, 2-ply 5¼" wide, 3-ply 5¼" wide, 2-ply 2(5) 12" 370 280 280 As shown 3 12" 555 415 415 24" 505 380 520 – 2 19.2" 635 475 655 16" 760 570 785 Screw Length 3½" 3½" 3½" 24" 680 510 510 As shown 2 19.2" 850 640 640 16" 1,020 765 765 24" 485 365 365 As shown 2 19.2" 610 455 455 16" 730 545 545 Screw Length 33 ⁄8" 5" 33 ⁄8" 24" 580 450 435 One side 2 19.2" 725 565 545 only 16" 870 675 655 24" 800 450 600 One side 2 19.2" 1,000 565 750 only 16" 1,200 675 900 (1) Nailed connection values may be doubled for 6" on-center or tripled for 4" on-center nail spacing. (2)Washers required. Bolt holes to be 9⁄16" maximum. (3)24" on-center bolted or screwed connection values may be doubled for 12" on-center spacing. (4)When loading the head side of a SDW22 screw, assemblies B, D, and F can be increased by 30%. (5)For beams up to 14" deep, maximum. (6)Assembly F is not recommended for TimberStrand® LSL or Parallam® PSL. Assembly D Assembly F 2" 2" 13⁄4" 31⁄2" 13⁄4" 31⁄2" 7" wide, 3-ply 245 370 465 580 695 3½" 455 565 680 325 405 485 6¾" 415 515 620 400 500 600 7" wide, 2-ply 7" wide, 4-ply 860 1,075 1,290 6" 1,360 1,700 2,040 340 425 505 6" 555 695 835 325(6) 405(6) 485(6) 6¾" 415 515 620 400 500 600 13⁄4" 6¾" 620 775 930 800 1,000 1,200 Uniform Load Design Example 300 PLF First, check allowable load tables on pages 6 – 23 to verify that three pieces can carry the total load of 715 plf with proper live load deflection criteria. Maximum load applied to either outside member is 415 plf. For an assembly of three 13⁄4" plies (Assembly B), two rows of 10d (0.128" x 3") nails at 12" o.c. center is good for only 280 plf. Therefore, use three rows of 10d (0.128" x 3") nails at 12" o.c (good for 415 plf). Alternative: Two rows of 1⁄2" A307 bolts or 31⁄2" USP WS screws at 19.2" on-center. 415 PLF Multiple-Member Connections for Top-Loaded Beams Fastener Installation Requirements When fasteners are required on both sides, stagger fasteners on the second side so they fall halfway between fasteners on the first side. Piece Width Number of Plies Type (1) 10d nails 12d–16d nails Screws 10d nails 12d–16d nails 2 1¾" Load must be applied evenly across entire beam width. Otherwise, use connections for side-loaded beams L6 Multiple pieces can be nailed or bolted together to form a header or beam of the required size, up to a maximum width of 7" 3 Screws 10d nails(3) 12d–16d nails(3) 4 Screws 3½" Screws 2 ½" bolts Min. Length 3" 3¼" 33∕8" or 3½" 3" 3¼" 33∕8" or 3½" 5" 3" 3¼" 5" or 6" 6¾" 5" or 6" 6¾" 8" Fastener # Rows 3(2) 2(2) 2 3(2) 2(2) O.C. Spacing 12" Location One side 24" 12" 2 24" 3(2) 2(2) 12" 2 24" 2 24" 2 24" Both sides Both sides One side One side (per ply) Both sides One side Both sides One side – (1)10d nails are 0.128" diameter; 12d–16d nails are 0.148"–0.162" diameter; screws are SDS, USP WS, TrussLOK-EWP™ or SDW. (2)An additional row of nails is required with depths of 14" or greater. (3)When connecting 4-ply members, nail each ply to the other and offset nail rows by 2" from rows in the ply below. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 28 MULTIPLE-MEMBER CONNECTIONS FOR SIDE-LOADED BEAMS L18 Point Load—Maximum Point Load Applied to Either Outside Member (lbs) Fastener Pattern Assembly A Fastener Type 10d (0.128" x 3") Nail SDS USP WS TrussLOK-EWP ™ SDW22(1) Number of Fasteners Location per Side 6 12 As shown 18 24 Screw Length 4 As shown 6 8 4 6 As shown 8 Screw Length 4 One side only 6 8 4 One side only 6 8 Assembly B Assembly C Assembly D Assembly E 2" 2" 2" 2" 13⁄4" 3½" wide, 2-ply 1,110 2,225 3,335 4,450 3½" 2,720 4,080 5,440 1,945 2,915 3,890 33 ⁄8" 2,320 3,480 4,640 3,200 4,800 6,400 13⁄4" 13⁄4" 31⁄2" 5¼" wide, 3-ply 5¼" wide, 2-ply 835 835 1,670 1,670 2,505 2,505 3,335 3,335 3½" 3½" 2,040 2,040 3,060 3,060 4,080 4,080 1,460 1,460 2,185 2,185 2,915 2,915 5" 33 ⁄8" 1,800 1,740 2,700 2,610 3,600 3,480 1,800 1,800 2,700 2,700 3,600 3,600 Assembly F 2" 2" 13⁄4" 31⁄2" 13⁄4" 31⁄2" 7" wide, 3-ply 740 1,485 2,225 2,965 3½" 1,815 2,720 3,625 1,295 1,945 2,590 6¾" 1,655 2,480 3,305 1,600 2,400 3,200 7" wide, 2-ply 2" 13⁄4" 7" wide, 4-ply 6" 5,440 8,160 10,880 6" 2,225 3,335 4,450 1,295(2) 1,945(2) 2,590(2) 6¾" 1,655 2,480 3,305 1,600 2,400 3,200 6¾" 2,480 3,720 4,960 3,200 4,800 6,400 (1)When loading the head side of a SDW22 screw, assemblies B, D, and F can be increased by 30%. (2)Assembly F is not recommended for TimberStrand® LSL or Parallam® PSL. Point Load Connector Spacing 4- or 6-Screw Connection 8-Screw Connection Nail Connection 10d (0.128" x 3") nails, typical. Stagger to prevent splitting. SDS, USP WS, TrussLOK-EWP™, or SDW screw, typical TrussLOK-EWP™, SDS, USP WS, or SDW screw, typical 2" spacing, typical 1½" minimum 2" at top and bottom, typical 1½" minimum L19 2" minimum 2" minimum Equal spacing ½ beam depth 2" minimum L20 8"–10" 11/2" minimum spacing, typical 2" minimum There must be an equal number of L21 nails on each side of the connection Point Load Design Example 3,000 lbs General Notes for Side-Loaded Beam Tables Connections are based on NDS® or manufacturer’s test or code reports. Use specific gravity of 0.5 when designing lateral connections. Values listed are for 100% stress level. Increase 15% for snow-loaded roof conditions or 25% for non-snow roof conditions, where code allows. When fasteners are required on both sides, stagger fasteners on the second side so they fall halfway between fasteners on the first side. Verify adequacy of beam in allowable load tables on pages 6–23. 7" wide beams should be side-loaded only when loads are applied to both sides of the members (to minimize rotation). Minimum end distance for bolts and screws is 6". Beams wider than 7" require special consideration by the design professional of record. ■ ■ ■ ■ ■ ■ ■ ■ 14" First, verify that a 3-ply, 1¾" x 14" beam can support a 3,000 lb point load and all other loads applied. The 3,000 lb point load is being transferred to the beam with a face mount hanger. For an assembly of three 1¾" plies (Assembly B), six 3½" SDS screws are good for 3,060 lbs with a face mount hanger. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 29 COLUMNS Allowable Axial Loads (lbs) for 1.3E TimberStrand® LSL Column Bearing Type On Column Base On Wood Plate(1)(2) Effective Column Length 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 3'–7' 8' 9' 10' 12' 14' 100% 12,165 10,745 9,120 7,550 6,235 5,195 4,375 3,725 2,785 2,155 5,765 5,195 4,375 3,725 2,785 2,155 3½" x 3½" 115% 13,665 11,830 9,810 7,985 6,525 5,400 4,525 3,840 2,855 2,200 5,765 5,400 4,525 3,840 2,855 2,200 125% 14,625 12,490 10,215 8,235 6,695 5,515 4,610 3,905 2,895 2,225 5,765 5,515 4,610 3,905 2,895 2,225 100% 15,210 13,435 11,400 9,440 7,795 6,490 5,465 4,655 3,480 2,695 7,065 6,490 5,465 4,655 3,480 2,695 3½" x 4 3 ⁄ 8" 115% 17,085 14,790 12,265 9,980 8,160 6,750 5,655 4,795 3,565 2,750 7,065 6,750 5,655 4,795 3,565 2,750 125% 18,280 15,610 12,765 10,295 8,370 6,895 5,765 4,880 3,615 2,780 7,065 6,895 5,765 4,880 3,615 2,780 Column Size 3½" x 5½" 100% 115% 125% 19,120 21,475 22,980 16,885 18,590 19,625 14,335 15,420 16,050 11,865 12,550 12,945 9,800 10,255 10,520 8,160 8,485 8,670 6,870 7,110 7,245 5,850 6,030 6,135 4,375 4,485 4,545 3,385 3,455 3,495 8,740 8,740 8,740 8,160 8,485 8,670 6,870 7,110 7,245 5,850 6,030 6,135 4,375 4,485 4,545 3,385 3,455 3,495 100% 25,205 22,260 18,895 15,640 12,915 10,755 9,060 7,715 5,770 4,465 10,785 10,755 9,060 7,715 5,770 4,465 3½" x 7¼" 115% 28,310 24,505 20,325 16,540 13,520 11,185 9,370 7,950 5,910 4,555 10,785 10,785 9,370 7,950 5,910 4,555 125% 30,290 25,870 21,155 17,060 13,870 11,430 9,550 8,085 5,995 4,610 10,785 10,785 9,550 8,085 5,995 4,610 100% 29,985 26,480 22,480 18,610 15,365 12,795 10,775 9,175 6,860 5,310 12,830 12,795 10,775 9,175 6,860 5,310 3½" x 8 5⁄ 8" 115% 33,680 29,155 24,180 19,680 16,085 13,305 11,150 9,460 7,030 5,420 12,830 12,830 11,150 9,460 7,030 5,420 125% 36,035 30,780 25,170 20,300 16,500 13,595 11,360 9,620 7,130 5,485 12,830 12,830 11,360 9,620 7,130 5,485 7" x 7" 115% 40,000 40,000 40,000 40,000 40,000 40,000 35,785 29,640 24,860 21,110 18,125 15,715 125% 40,000 40,000 40,000 40,000 40,000 40,000 36,720 30,300 25,345 21,475 18,405 15,935 (1) Wood plate bearing is based on compression perpendicular-to-grain stress of 425 psi adjusted per the NDS®, 3.10.4. (2) See connection details below. Allowable Axial Loads (lbs) for 1.8E Parallam® PSL Column Bearing Type On Column Base Effective Column Length 6' 7' 8' 9' 10' 12' 14' 16' 18' 20' 22' 24' 3½" x 3½" 100% 115% 125% 10,595 11,200 11,545 8,735 9,140 9,370 7,265 7,550 7,715 6,115 6,320 6,440 5,200 5,355 5,445 3,885 3,980 4,030 3,000 3,065 3,100 3½" x 5¼" 100% 115% 125% 15,890 16,800 17,320 13,105 13,710 14,060 10,900 11,325 11,570 9,170 9,480 9,660 7,800 8,035 8,170 5,825 5,965 6,050 4,500 4,595 4,645 100% 21,190 17,475 14,535 12,225 10,400 7,765 6,005 Slenderness ratio exceeds 50 Column Size 3½" x 7" 5¼" x 5¼" 115% 125% 100% 115% 125% 22,395 23,095 33,295 36,675 38,735 18,280 18,745 30,010 32,545 34,030 15,100 15,425 26,650 28,490 29,555 12,640 12,880 23,475 24,835 25,620 10,715 10,895 20,660 21,695 22,290 7,955 8,065 16,160 16,805 17,175 6,125 6,195 12,890 13,315 13,560 10,480 10,775 10,950 8,670 8,885 9,010 7,285 7,445 7,535 ■ ■ 5¼" x 7" 115% 125% 40,000 40,000 40,000 40,000 37,985 39,410 33,115 34,165 28,925 29,725 22,405 22,900 17,755 18,080 14,370 14,595 11,850 12,010 9,925 10,050 100% 40,000 40,000 40,000 40,000 40,000 40,000 34,155 28,485 24,020 20,475 17,630 15,325 Top or Bottom Plate Connection General Notes ■ 100% 40,000 40,000 35,530 31,300 27,545 21,545 17,185 13,970 11,560 9,710 Tables are based on: – Solid, one-piece column members used in dry-service conditions – Bracing in both directions at column ends –NDS® –Simple columns with axial loads only. For side loads or other combined bending and axial loads, see the NDS® Two 16d (0.162" x 3½") nails for every 1¾" of column width, nailed through the plate into the column Allowable loads have been adjusted to accommodate the worst case of the following eccentric conditions: 1⁄6 of column thickness (first dimension) or 1⁄6 of column width. Beams and columns must remain straight to within L is the unrestrained length of the member in feet. 5L2⁄4608 (in.) of true alignment. For column allowable design stresses see page 5. Wide face of strands The column and connector values listed are for dry-service conditions only. When wet-service conditions exist, contact your Weyerhaeuser representative for other product solutions. Wide face of strands In order to use the manufacturer’s published capacities when designing column caps, bases, or holdowns for uplift, the bolts or screws must be installed perpendicular to the wide face of strands as shown at left. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 30 DO NOT install bolts or screws into the narrow face of strands COLUMNS Column Caps for TimberStrand® LSL and Parallam® PSL Column Product Beam Width Location on Beam End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate Column Size 3½" x 3½" 1.3E TimberStrand ® LSL 31 ⁄ 2 " 3½" x 5½" 3½" x 7¼" 3½" x 3½" 31 ⁄ 2 " 3½" x 5¼" 5¼" x 3½" 1.8E Parallam ® PSL 51 ⁄4" 5¼" x 5¼" 5¼" x 7" 7" x 3½" 7" 7" x 5¼" 7" x 7" Simpson Strong-Tie ® Connector Load (lbs) ECC44 7,655 CC44 15,310 ECC46 12,030 CC46 24,060 ECC48 16,405 CC48 24,060 ECC44 7,655 CC44 15,310 ECC46 12,030 CC46 24,060 ECC64 12,030 CC64 28,586 ECC66 18,905 CC66 30,250 ECC6-71 ⁄8 24,060 CC6-71 ⁄8 37,810 ECC71 ⁄8-4 18,375 CC71 ⁄8-4 34,736 ECC71 ⁄8-6 28,875 58,500 CC71 ⁄8-6 ECC71 ⁄8-71 ⁄8 36,750 CC71 ⁄8-71 ⁄8 57,750 USP Structural Connectors ® Connector Load (lbs) KECC44 12,030 KCC44 15,315 KECC46 18,595 KCC46 24,065 KECC48 20,780 KCC48 24,065 KECC44 12,030 KCC44 15,315 KECC45 16,405 KCC45 24,065 KECC64 25,780 KCC64 37,815 KECC66 25,780 KCC66 37,815 KECC57 31,170 KCC57 36,095 – – – – KECC75X 45,940 KCC75X 56,875 KECC77X 45,940 KCC77X 56,875 Beam on Column Cap P1 Column Base P2 Column Bases for TimberStrand® LSL and Parallam® PSL Column Product 1.3E TimberStrand ® LSL 1.8E Parallam ® PSL Column Size Simpson Strong-Tie ® Connector Load (lbs) ABA44Z 6,000 LCB44 Post or concrete control 3½" x 7¼" ABA46 LCB46 CB48 9,435 Post or concrete control Post or concrete control 3½" x 3½" LCB44 3½" x 5¼" LCB46 3½" x 7" CB71 ⁄8-4 5¼" x 5¼" LCB66 3½" x 3½" 31 ⁄ 2" x 5½" 5¼" x 7" 7" x 7" Post or concrete control CB6-7 CB71 ⁄8-6 CB71 ⁄8-7 USP Structural Connectors ® Connector Load (lbs) PA44 5,135 PAU44 6,775 CBSQ44-TZ 6,775 KCB44 Post or concrete control PA46 6,285 KCB46 Post or concrete control KCB48 Post or concrete control CBE44 KCB44 CBE46 KCB45 KCB47 KCB74 Post or concrete control CBE66 KCB66 Elevated Column Base Optional non-shrink grout P3 Beam on Column 11⁄8" TJ® Rim Board or 1¼" TimberStrand® LSL blocking for lateral support KCB76 KCB77 Strap per code if top plate is not continuous over column General Notes ■ Capacities shown cannot be adjusted for duration of load. ■ Connector capacities assume a beam material with a minimum perpendicular-to-grain bearing of 625 psi. ■ ■ Column Connector capacities may be more than the column capacity; therefore, check both the connector and the column capacity and use the lower capacity. Other connectors may be available. Capacities may vary depending on orientation of member. Contact the hanger manufacturer for more information. Trus Joist® Beam, Header and Column Specifier's Guide (California) TJ-9020 | July 2016 31 L1 We Can Help You Build Smarter You want to build solid and durable structures—we want to help. Weyerhaeuser provides high-quality building products and unparalleled technical and field assistance to support you and your project from start to finish. Floors and Roofs: Start with the best framing components in the industry: our Trus Joist® TJI® joists; TimberStrand® LSL rim board; and TimberStrand® LSL, Microllam® LVL, and Parallam® PSL headers and beams. Pull them all together with our self-gapping and self-draining Weyerhaeuser Edge GoldTM floor panels and durable Weyerhaeuser roof sheathing. Walls: Get the best value out of your framing package—use TimberStrand® LSL studs for tall walls, kitchens, and bathrooms, and our traditional, solid-sawn lumber everywhere else. Cut down installation time by using TimberStrand® LSL headers for doors and windows, and Weyerhaeuser wall sheathing with its handy two-way nail lines. Software Solutions: Whether you are a design professional or lumber dealer, Weyerhaeuser offers an array of software packages to help you specify individual framing members, create cut lists, manage inventories—even help you design a complete structural frame. Contact your Weyerhaeuser representative to find out how to get the software you need. Technical Support: Need technical help? Weyerhaeuser has one of the largest networks of engineers and sales representatives in the business. Call us for help, and a skilled member from our team of experts will answer your questions and work with you to develop solutions that meet all your structural framing needs. CONTACT US 1.888.453.8358 • woodbywy.com/contact Contact your local representative or dealer at: Visit woodbywy.com/warranty for copies of this and other Trus Joist® Engineered Wood Product warranties. July 2016 • Reorder TJ-9020 This document supersedes all previous versions. If this is more than one year old, contact your dealer or Weyerhaeuser rep. , Weyerhaeuser, Microllam, Parallam, TimberStrand, TJ, TJI, and Trus Joist are registered trademarks and Edge Gold is a trademark of W eyerhaeuser NR. © 2016 Weyerhaeuser NR Company. All rights reserved. Printed in the USA.
Similar documents
TimberStrand, Microllam, and Parallam Beams
Why Choose Trus Joist® Beams, Columns, and Headers? • Reliable performance • Consistent quality and dependable uniformity • Flexible solutions for your beam and header needs • Backed by a limite...
More informationsnow roof load tables - Standard Building Supplies Ltd.
Non-Snow Roof Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Beam Details Window and Door Header Details Nailing on Narrow Face Allowable Holes Bearing Length Requirements Tapered End C...
More informationParallam (PSL) - Atlas Structural Systems
Code Evaluations: See ICC ES ESR-1387 and HUD MR 1265
More informationTimberStrand, Microllam, and Parallam Beams
cost in the end. Trus Joist® TimberStrand® LSL, Microllam® LVL, and Parallam® PSL are structural solutions you can count on—guaranteed.
More information