Quick View Ad Book
Transcription
Quick View Ad Book
Quick View Ophthalmic Surgical Instruments Available From Rhein Medical • Choppers • Diamond Knives • Dry Eye • Forceps • ICL • Lens Cutters • Miscellaneous • Refractive • Scissors • Single-Use Elevating The Quality Of Care In Ophthalmology 800-637-4346 Company Information ORDERS We employ people at Rhein Medical, not answering machines. When you call us during our normal business hours, you will reach a responsive customer service professional, not an electronic routing system. We will answer your questions, or process your orders, with a minimum of delay. Our most important concern is you. We operate customer service hours from 8:30 AM to 5:00 PM E.S.T., and orders and questions may be presented Monday through Friday during these hours. We offer a toll free telephone number in the U.S.A.: 800-637-4346. Orders or questions may also be presented by facsimile: 727341-8123, or by email: [email protected]. International calls may be placed by calling our main telephone number: 727-209-2244. You may also place your questions and orders through our international distribution system. Check our website: www. rheinmedical.com for the distributor in your territory or country and Live Chat about any of our products. PRICES Prices are subject to change without notice. Please contact our customer service department for a current price list, or feel free to call for a cost quotation. SHIPPING Most shipments are made through UPS using Second Day (Blue) shipping within the U.S.A. However, should you require overnight shipping, please let us know. We also ship through other carriers at our customers’ request. The selection of carrier for international shipments is based upon the country of destination. All shipments are F.O.B shipping point (St. Petersburg, Florida). All in-stock orders received by 2:00 PM E.S.T. are shipped on the same day. TERMS OF PAYMENT Payments are due within 30 days from receipt of our products. We accept VISA, MasterCard, and American Express credit cards. Wire transfers, personal or cashiers checks drawn on a U.S. bank may also be accepted for international shipments. Cash is also accepted. Elevating The Quality Of Care In Ophthalmology 800-637-4346 Contents Contents..........................................1 Choppers.........................................2 Diamond Knives...............................5 Dry Eye..........................................17 Forceps..........................................23 ICL ...............................................31 Lens Cutters...................................33 Miscellaneous ...............................35 Refractive......................................50 Scissors.........................................64 Single-Use .....................................66 Speculums.....................................69 Index............................... Back Cover www.rheinmedical.com Elevating The Quality Of Care In Ophthalmology 800-637-4346 1 Choppers 8- 14 56 2- 8 -14 56 2- R :C P ha Su ick ng L: rg , R Ch C h eo ig o Ti an n ht pp P p, g H er i D ck D Ch an , 1 om , ou o d .7 Le b p D 5 in f le p om m an t H E er m , n t in T Su and de 1.7 an ip d 5m rg t ,D W m eo it ou n h bl e En de d W it h Chang* Choppers nd h ig ,R p Ti a tH nd m f Le 5m .7 p, i 1 T , er on m m pp rge 5 o u 7 Ch t S 1. g n r, on an ina pe rge h p C m o Su R: Do Ch 6g ant 6 n a 5 in 14 Ch om 8L: D 6 56 14 8 a tH For More Information Please Contact Our Customer Service: 800-637-4346 2 1288 Rev.A 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Shiao H. Chang, Ph.D. FRESCO OF ADAM AND EVE, Ralphael AHAJ Choppers lo se d Ti ps Aguilar* Pre-Chopper C 1. at io n 4m m ed Activat Tip Se r pa le nd d Ha uilar* 9: Ag 4 3 1 0 Roun pper, ho Pre-C 8- • Ideal For Pre-Chopping Grade III, IV, And V Cataracts. • Smaller Blades Are Easier To Pass Through A 2.0 Millimeter Phaco Incision. • Special Beveled Blades Allow Pre-Chopping With Both Anterior And Posterior Surfaces. • Reusable, Autoclaveable, Made In The U SA , O f fe re d Fo r A 30 - Day Surgical Evaluation Without O b l i g a t i o n , & Instructional Video Is Available For Viewing On Our Website. Call 800-637-4346, For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Roberto Aguilar, M.D. Girl-with-a-Pearl-Earring, Vermeer 1279 Rev.B AEAJ 3 Choppers Quick Pick Choppers For Vertical Chopping With One Instrument ing igat -Irr n , No per p in e : Rh 558 4 8-1 g tin iga Irr er, p op Q ein 55 14 8- h kC Pic k c ui Rh I: 8- ho kC Pic ck i u Q g in at g ri r -I on ,N er pp ck ho C k ic P ui ed Q m g in * in r Fo ig at m ha ic r, Ir r :N 59 pe 5 14 8- 14 55 9- I: Ni ch a m in * Fo r m ed Q ui ck Pi ck Ch op 8- • Designed To Quick Chop With Only One Instrument. • Special Pointed “ P i c k ” Tip Allows Vertical Chopping Of Hard Nuclei. • Reusable, Autoclaveable, Made In The USA, & Guaranteed For Life. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716• 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Louis D. Nichamin, M.D. 4 1188Rev.B Rev.A 1188 Angel with Thorn Wreath, Bernini AGBC Diamond Knives NEW 2.2mm Diamond Knives e* ad m m .2 2 e, l B dl ed gl n ,A an H e® ad -D Bl :3 nd 3 09 05- 902 2: C lea rC o rne a2 .2m mS har p On The Sid eC VD Dia mo -5 05 New 2.2mm Wide Diamond Knives For Small Incision Surgery. Lifetime Guarantees On The Titanium Handles. The Best You Can Buy. Contact 727-209-2244 For More Information 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *U.S. Patent No. Re. 37,304 Fontana de Oceana, Giambologna AJAG 5 Diamond Knives Simply The Best Diamond Knives You Can Buy! * ® e ad l B m 3 5- id 2. d le : 86 D 3- d le ng 8: B 2. ez A D 3- d oi m m .5 2 0- ap Tr 50 05 e ad l o ez ng * ® m .5 ap Tr A 8 50 - 05 No Other Diamond Like It On The Planet! New Configurations Also Available: 05-5087: 3-D Step Trapezoid, 2.5-3.5mm Blade®* 05-5089: 3-D Step Trapezoid, 2.0-2.5mm Blade®* 05-5094: 3-D Angled Step Trapezoid, 2.5-3.5mm Blade®* 05-5097: 3-D Angled Trapezoid, 1.2mm-1.4mm Trap Blade®* 05-5099: 3-D Angled Trapezoid, 1.0-1.2mm Blade®* 05-5103: 3-D Angled Trapezoid, 1.75-1.95mm Blade®* 05-5104: 3-D Angled Trapezoid, 1.8-2.2mm Blade®* The Patented Sloping Bevels Of The Blade Provide A Linear Perpendicular Incision Through Descemet’s & Bowman’s Membranes, Without Inducing Corneal Distortion. The Sloping Bevels Bend Stromal Tissue As The Blade Is Advanced, Providing A More Water-Tight Incision. Call 800-637-4346 For More Information. 6 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Patent Number RE37 ,304 1249 Rev.C Background Art Rhein Stylized Eye 2 BAAJ Diamond Knives 3-D* Diamond Knives® For BI-Manual Phaco led Ang -D* 3 : 6 m .5m -3 .5 d2 oi pez Tra ® de Bla 508 05 e lad le, 1.4 dH gle n ®, A de d an B mm a 09 -5 05 l *B -D 3 6: d le ng A e ®, ad de Bl a l id B * zo -D pe 3 a : r 97 T m m .4 1 m 2m . 1 e, dl n a H 0 -5 05 Call 800-637-4346 For More Information 1288 1205Rev.A Rev.B 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *U.S. Patent No. Re. 37,304 Justice, Pollaiuolo BAAE 7 Diamond Knives Rhein Advantage Diamond & Sapphire Knives m. ge vanta 5: Ad -508 iu Titan nife, ion K Incis xing la al Re imb ond L Diam 05 - 0 90 Pr es et s R hein A dvantage I Diamond & S ap P hire K ni V es : T h e s e U n i q u e 10-Facet Blades (05-5085: D i a m o n d A n d 05-9006 : S a p p h i re ) H ave S n u b - N o s e T ip C on f ig u r at ion s For More P redictable T rack ing Through Stroma, A nd A re Shar p A round All Edges For Ambidextrous Cutting. The Blades Are 1mm Wide, And Have Preset Calibration Settings Of 300 & 600 Microns, Including Full Advancement And Full Retraction. Ideal For Performing A Stab 1mm Paracentesis, 300 Micron Step-Groove Incision, 600 Micron Langerman Single-Hinge Incision, Straight & Arcuate AK And LRI 600 Micron Incisions, Trabeculectomies, And Tunneling Into The A nter ior Chamber Through The Phaco Incision. 05 -9 00 7: Ad va nt ag e II Sa pp hi re 0. 75 m m 05 m 1m ub Sn & s et es Pr Sh ar p ge ta an dv A 6: ire ph ap S I ife Kn e id W m 3m 0. , se No m 6m 0. w /B lu nt Ed ge s, .3 ,. 55 ,& .6 m m 5: 09 -5 05 d on am Di II e g nta va Ad ing lax Re al b Lim . ium an Tit , e if Kn on isi Inc Rhein Advantage II Diamond & SapPhire Knives: These Blades ( 05 -5095 : D ia mond A nd 05-9007: Sapphire) Have Sharp Tips With Four Converging Bevels For More Efficient Penetration. The Blades Are 0.75mm Wide With Blunt Side Edges, And Can Be Held Inside A 750 Micron Paracentesis For Fixation Of The G l o b e D u r i n g P h a c o T u n n e l Construction. The Blades Have Preset Calibrations Of 300, 550, And 600 Microns, Including Full Advancement And Full Retraction, Offering Multiple Astigmatic Incision Alternatives. Ideal For Performing A 0.75mm Stab Paracentesis, 300 Micron Step-Groove Incision, 550 & 600 Micron Langerman Single-Hinge Incision, Straight & Arcuate AK And LRI 600 Micron Incisions. The Knives Have Single Footplates Which Are Mirror Polished For Effortless Gliding Across The Cornea And Sclera, And The Footplate Tip Profiles Are Downsized For Maximum Visualization. Available For A Surgical Evaluation Without Obligation. Reusable, Autoclaveable, Made In The U.S.A., And The Handle And Internal Components Are Guaranteed For Life. Call 800-637-4346 For More Information 8 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 1246 Rev.A 1073 Rev.D Lydia Leaning On Her Arms, Seated In A Loge, Cassatt (1879) BAAJ Diamond Knives New CVD Diamond Knives : C le On ar Co r Th e S nea 1 ide .8 CV mm D D Sh iam arp on d W) (NE arp Sh nd m o m 2.2 Diam a e D V rn Co ide C ar S e l e h : C 22 On T -90 5 0 p ar d Sh on m am i 4m D . 2 D a V ne e C r o id C r eS a h le T C : On 3 2 90 05 ) EW (N (NE W) 05 -90 25 Additional Precision Widths Available 05-9008: Trapezoid 2.5mm-3.5mm CVD Diamond, Angled 05-9009: Clear Cornea 2.8mm Sharp On The Side CVD Diamond 05-9011: Clear Cornea 3.2mm Sharp On The Side CVD Diamond 05-9012: Clear Cornea 2.65mm Sharp On The Side CVD Diamond 05-9014: Clear Cornea 3.0mm Sharp On The Side CVD Diamond 05-9014-ST: 3.0mm CVD Diamond, Sharp Side Edges, Straight Handle 05-9016: Trapezoid 2.5mm-3.0mm CVD Diamond, Anterior Bevels, Angled 05-9017: Trapezoid 2.5mm-3.2mm CVD Diamond, Anterior Bevels, Angled 05-9018: 1.0mm CVD Diamond, Single Beveled, Blunt Side Edges, Angled 05-9019: 1.2mm CVD Diamond, Single Beveled, Blunt Side Edges, Angled 05-9020: 1.4mm CVD Diamond, Single Beveled, Blunt Side Edges, Angled 05-9024 Clear Cornea 2.8mm Blunt On The Side CVD Diamond For More Information, Please Call 800-637-4346 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 1295 Rev.A Self Portrait, DaVinci AJAJ 9 Diamond Knives CVD Diamond Knives... mm -3.5 d, 2.5 mon d i a i D zo ape CVD d Tr 08: Angle On 0 9 rp 05Sha m, 1.5m amond i oid d z D e D ngle ap V r A T C , s 21: 1.8mm r Bevel 0 9 05 erio Ant D d CV Angle es mm id 5 S 6 . e a 2 On Th orne ar C , Sharp : Cle nd 2 o 1 0 m Dia 05-9 .8mm ornea 2 : Clear C VD Diamond, C 05-9009 d le g An ides n The S Sharp O 05-9014: Clear Cornea 3.0mm Angled CVD Diamond, Sharp On The Sides 05-9011: Clear Corn ea 3.2mm Angled CV D Diamon d, Sharp On the Sides 05-9 013: Cresc e Sharp nt 1.4mm C On T he Sid VD Diam ond es , ...Incredible Sharpness At A Manageable Cost. 05- 902 5: Cle a • Proven CVD Diamond Blade Sharpness The r Cor Sid nea 1 Improves Tissue Reapproximation, Enhances eC VD .8mm Healing, And Insures A Superior Postoperative Result. D S iam • CVD Diamond Blades Offer Unlimited Uses When Maintained Properly. Handles & Internal Components Made Of Titanium. h ond arp O n • Available In Multiple Blade Configurations & Widths To Match All Phaco Tip And Implant Requirements. • Reu sable, Autoclaveable, Handles Guaranteed For L ife, And Available For A Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 10 All Rhein Products Meet The Requirements Established Within The European Union 1137 Rev.C Virgin Enthroned, DaVinci AFAJ Diamond Knives Fine Tune Your LRI Procedure en Ext Fully d de tin et S rk Ma Zero g g e at pl ot Fo e gl in in tt Se S d on er et om icr iam w/ fe ni K D M RI /L AK et ng s 03 -5 05 c ifa Tr : 5 n ro t Se ti • New Diamond Knife Mic Precise (05-5035) With A Micrometer Handle, Designed To Dial An Exact Extension Of The Diamond Blade. • Special Single Footplate Allows Maximum Visibility, With Titanium Handle & Spring. • U n i q u e 1 m m S n u b N o s e B l a d e Tr a c k s B e t t e r In Tissue, And Can Also Be Dialed To Full Extension For Making A Paracentesis. Reusable, Autoclaveable, Ma de In The USA, Handle Guaranteed For Life & Available For A Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. • 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 1194 Rev.A Giorgione, Judith AEAE 11 Diamond Knives Precise LRI Diamond Knife Performance. * nife ond K 39: 05-50 Diam l LRI Seibe ion ect Dir Cut Of •Unique In-line Footplates Are Turned 90 Degrees To Allow Full Visualization Of The Diamond Blade While Performing The LRI Incision. •Special Mirror-Polished Double Footplate Construction Insures Precise Blade Depth Penetration. •Pre-Set Blade Extension Settings Of 0.5mm,0.55mm, 0.6mm, Including Full Retraction And Full Extension. •1mm Wide Snub Nose Diamond Blade Is Ideal For Making The Paracentesis Incision. •All Components Are Made Of Titanium, Including The Spring. ** fe d Kni on I Diam R L l e b rt/Sei Same Features As The Above Knife, With Exception To The Blade. This Blade Has A Sharp Point And Measures 1.2mm –1.4mm To Make The Incisions For MICS Surgery, And The LRI. • Both Diamond Knives Are Reusable, Autoclaveable, Made In The USA, Handle Guaranteed For Life, And An Instructional Video Is Available at www.rheinmedical.com Of • ion ect Dir Cut eine 40: St 05-50 Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Barry S. Seibel, M.D. **Developed In Coordination With Roger F. Steinert, M.D. & Barry S. Seibel, M.D. Rodin, The Thinker 12 1224 Rev.D AEAJ Diamond Knives New 1.8mm Micro Diamond Knives m d gle n ,A de® de* Bla 0 -51 05 -9 02 5: C le ar C or ne a 1. 8m m Sh ar p O n Th e Si de C V D D ia m on d 05 Bla 3-D 2: e, ndl Ha m 1.8 Ex q u is ite 1. 8mm Di amond K ni ve s Wi t h Titanium Retractable Handles. Simply The Best And Sharpest Diamond Blades You Can Buy. Contact 727-209-2244 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *U.S. Patent No. RE37,304 Madonna Of Pomegranate, Botticelli 1284 Rev.A AEAJ 13 Diamond Knives Rhein 3-D Diamond Knives* For Unparalleled Incision Architecture de* Bla m .4m e, 2 l d hs Han i d t ade* d e W l l g ® , An i o n .50mm BBladee** s i e 2 m c , d ad P r e ed Handdlele, 2.8000mmm BBl lade** Bla l D l a . n g a , 3 0mm Blade , An led H dle 2 1: 3 * ion d i t 3-D Blaaddee , Annggled HHaanndle, -33..50mmm Blaaddee* 510 d 5 A 81: -D Bl e , A gled 2.50 2.65m Bl e* 0 ® ® ® n 3 , id ad 50 lad mm 05- 082: 3-D B ade® , A rapezo andle , 2.20 m Bl de H 5 l dle 1.40m m Bla 05- 083: 3-D B gled T ngled n a , H 5 n dle 80m 05- 084: 3-D A ade® , A ngled Han dle, 1. 5 l 05- 086: 3-D B ade® , A ngled an H 5 l A ® 05 091: 3-D B ade , ngled 5 l 05- 093: 3-D B ade® , A 5 l 05- 096: 3-D B 5 05 102: 5 05 3-D Fa cet Design, Front View Our Patented 3-D Diamond O f fe r Blades Unsurpassed Inci sion A rchitecture. Asymmetrically Converging Bevels Force T issue In Three Opposing Directions Within The Tunnel, Resulting In A More Torturous Path For Fluid Egression. Used By Top Surgeons Around The World, Our 3-D Blades Provide The Most Pristine, Water-Tight, And Technically Advanced Incisions On The Planet. The Results Will Astound You. Available On Self-Locking Titanium Handles With All Titanium Components, Which Are Guaranteed For Life. Available With A Complimentary Cleaning System, And An Instructional DVD. Contact 727-209-2244 For A No-Obligation Test Drive. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *U. S. Patent Number: RE37,304 14 1275 Rev.B Leonardo Da Vinci Self Portrait ACAJ Diamond Knives New 3-D* Parallel & Trapezoidal Diamond Blades , dle - d gle n ®, A e ad Bl de* D a Bl :3 02 8mm 1 -5 1. n Ha m 0m 1.8 3-D 2.2 Ang le 0m m d A Bla ngl de* ed Tra pez oid 05 -51 04 : 05 -5 10 3 :3 1. -D 95 , A m ng m le B d la Tr de a * pe zo id 1. 75 - m m 05 Additional Precision Widths 05-5081: 05-5082: 05-5083: 05-5084: 05-5086: 05-5088: 05-5091: 05-5093: 05-5096: 05-5097: 05-5099: 05-5101: 3-D 3-D 3-D 3-D 3-D 3-D 3-D 3-D 3-D 3-D 3-D 3-D Blade®, Blade®, Blade®, Blade®, Angled Angled Blade®, Blade®, Blade®, Angled Angled Blade®, Angled Handle, 2.50mm Angled Handle, 2.80mm Angled Handle, 3.00mm Angled Handle, 3.20mm Trapezoid 2.50-3.50mm Trapezoid 2.00-2.50mm Angled Handle, 2.65mm Angled Handle, 2.20mm Angled Handle, 1.40mm Trapezoid 1.20mm-1.40m Trapezoid 1.00mm-1.20m Angled Handle, 2.40mm Blade* Blade* Blade* Blade* Blade* Blade* Blade* Blade* Blade* Blade* Blade* Blade* For More Information, Please Call 800-637-4346 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 813-885-5050 •727-209-2244 • Fax: 813-885-9346 Email: [email protected] • Website: www.RheinMedical.com * (U.S. Patent No. RE37,304) 1172 Rev.CRev.B 1293 Virgin Enthroned, DaVinci BAAJ AJAJ 15 Diamond Knives The Diamond Knife Cleaning System From Rhein Medical Reviewed by Roger Steinert*, M.D. Dr. Steinert is Professor and Chair Director, Gavin Herbert Eye Institute UC Irvine. He is an internationally recognized leader in refractive surgery, cataract surgery, and corneal transplantation. Here Is What Doctor Steinert Said: “The Rhein Diamond Knife Cleaning System Has Dramatically Improved The Visible Cleanliness Of Our Blades. They Now Sparkle, Instead Of Having Dried Debris And Spots When We Get Them Back From The Instrument Room. As A Result, Tissue Drag Is Absent, And Surgeons Perceive The Blade As Sharper. A Major Bonus Has Been The Reduction In Blade Damage, As The Diamond No Longer Is Exposed To Potential Trauma During The Cleaning Process. Our Instrument Tech Raves About The System — She Says She Can't Live Without It.” Features & Benefits Of The Diamond Knife Cleaning System (09-7017 & 09-7018) • Safe Way To Clean Delicate Blades. • Fluid-Soaked, Foam Filled Cleaning & Rinsing Wells Reduce The Risk Of Damage To Blades During Cleaning. • Can Be Used For Stainless Steel Blades. • Saves Time (no need for ultrasonic cleaning). • Removes Stubborn Debris. • Self-Contained, Ready-To-Use System. • Refills Are Foil Sealed And Come In A Dispenser Box Of 12. Step 1: Pass The Blade Up And Down Through Our Proprietary Blue Cleaning Solution Pad. Several Passes Will Remove Even Stubborn Tissue And Debris From The Blade Surface And Mount. Step 2: Rinse The Blade In The Upper Left Rinsing Well. Step 3: Rinse The Blade In The Upper Right Rinsing Well. Retract The Blade Into Its Handle And Sterilize According To The Manufacturer’s Instructions. Call 800-637-4346 For More Information 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Roger F. Steinert, M.D. Has No Proprietary Interest In This Product 16 Four Dancers in Blue, Degas, (1897) 1172 Rev.C BAAJ Dry Eye on Dry Eye Lid Squeezers i bu Me ® * or el id Co m pr es sio n kin as M : 716 8-01 m bu ei M ss re p Ex si Fo rce ps ** rs lle Ro d se o Cl m s re p Ex : 17 7 01 8- n te rd a H Ey Meibum Expression Is Recommended As A Subsequent Procedure To Meibomian Gland Probing, Insuring The Patency Of Meibomian Glands. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Steven L. Maskin, M.D. ** Developed In Coordination With David R. Hardten, M.D. 1321 Rev.A Rhein Medical Stylized Eye BABB 17 Dry Eye New Maskin® * MGD Products es um 76 b Pro es m 0u 11 m 0u 15 b Tu rs ato Dil es um 0 15 b Tu r so um ib Me res xp E Call 727-209-2244 For More Information. Testimonial 18 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Steven L. Maskin, M.D. Testimonial PCT/US08/083318, Intraductal Meibomian Gland Probing Relieves Symptoms Of Obstructive Meibomian Gland Dysfunction, Maskin, Steven L, Cornea. 29(10):1145-1152, October 2010. 1325 Rev.A Mantegna, Madonna with Child & Cherubim BCBB Dry Eye STOP DRY EYE FAST! Meibomian Gland Probing Or (MGP) Is A Proven Simple Procedure That Takes Only Minutes In Your Examination Room, Using The Maskin™* Probe System. Cornea Cornea Meibum Flow Restored Probe Blockage Blocked Meibum Flow In Meibomian Gland BEFORE PROBING Lower Eye Lid Meibomian Gland AFTER PROBING Here Is What Matson Sewell, Of Boston, MA Said About Her Experience With Meibomian Gland Probing: “...The Meibomian Gland Probing Was Easy To Tolerate, And This Is From Someone Who Is Very Jumpy And Sensitive To Having My Eyes Worked On. I’ve Had Immediate, Significant Relieve After The Probing, Including A Significant Decrease In Burning And Stinging Discomfort, Light Sensitivity And Blurred Vision, Which Have Continued To Improve. I Can Tolerate Exposure To Things In The Environment Easily. I No Longer Awaken At Night With Eye Pain And Have To Put Drops In. I Hope The Meibomian Gland Probing Will Become Widely Available As I Know The Frustration Of Seeing Doctor After Doctor And Getting No Relief. I Also Hope That People Can Finally Get Effective Help Before Their Condition Gets As Incapacitating As Mine Was.” To Order A Starter Kit For Your DRY EYE Sufferers! Call 800-637-4346 RHEIN CODE RHEIN CODE 1316 Rev.B DRYEYE CODE 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Steven L. Maskin, M.D. PCT/US08/083318, Intraductal Meibomian Gland Probing Relieves Symptoms of Obstructive Meibomian Gland Dysfunction, Maskin, Steven L, Cornea. 29(10):1145-1152, October 2010. Stylized Eye, Rhein Medical DRYEYE CODE ABBB 19 Dry Eye Rhein Fire & Ice Mask Product #85-9005 • Pop It In A Microwave For 15 Seconds, For Heat Therapy. • Pop It In The Freezer For Cool Therapy. • Includes Cloth Sleeve For Additional Lid Protection. • Easy To Use, And Can Be Cleaned And Reused Multiple Times. • Available 5 Units Per Box. Call 800-637-4346 For More Information 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Woman Wearing Dry Eye Heat Mask 20 1301 Rev.B 1246 Rev.A 1073 Rev.D AGBA Dry Eye The Maskin™* Probe System Meibomian Gland Probing ... For Fast Immediate Dry Eye Relief... It Works! 2 Months Post Probing Pre-Probing “Using Maskin Meibomian Gland Probes Helps Many Of My Patients With Poor Meibomian Flow. Opening The Mechanical Obstruction Greatly Increases Oil Outflow Giving Great Relief To Most Patients. Using This New Tool Early, Along With Medications, Helps To Optimize Care Giving Quicker Improvement And Sustained Oil Flow. Often I Avoid The Side Effects Of Oral Antibiotics. I Use The Probes For Severe To Mild Obstruction.” -James Tearse, M.D. / Redwood City, CA “The Procedure Was Easy, Comfortable And Brief For The Patient. There Were No Technical Issues With The Product. I Was Surprised That I Encountered The Characteristic “Pop” Of A Fibrovascular Membrane In The Majority Of The Glands Probed. I Saw The Patients Back In Follow Up Three Days After The Procedures. One Patient Was So Pleased That He Offered Me A $100.00 Bill In Payment (I Had Told The Two That The Procedure Was New, That I Was Evaluating The Procedure And Therefore Would Not Charge Them For It.)” -Glenn N. Pomerance, M.D./ Chattanooga, TN “So Far My Data With The Maskin Probes Looks Great. All Patients Are Happy And Got Improvement When Used In Conjunction With Medical Management. One Of My Staff Members Needed It And Noticed Improvement That Day.” -Mitchell Jackson, M.D./ Lake Villa, IL “I Have Used The MGD System And Am Pleased With The Results. My Patients Have Been Very Gratified With Their Outcomes And Comfort. Thank You Steve (Steve Maskin, M.D.)! I Have Used It For Meibomian Gland Dysfunction, Secondary Dry Eyes, And Also Successfully Corrected Chalazions Wherein I Believe This Could Be The First Line Of Treatment Given Its Elegance, Minimal Intervention And Repeatability If Needed.” -Arun C. Gulani, M.D./ Jacksonville, FL TM * s kin be as Pro M o icr M TM * s n ki ube s a T M ro ic M Go to www.RheinMedical.com to view the entire Maskin™Probe System or call our customer service line at 800-637-4346 for more information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Steven L. Maskin, M.D. PCT/US08/083318 Judith Beheading Holofernes, Caravagio 1294 Rev.F AHBA 21 Dry Eye Maskin™* MGD Probe System The New Dry Eye Procedure.... Patients Are Talking About, From Around The Globe... “I was suffering greatly from severe dry eye, my life was on hold, with no interest in doing anything. I tried many, many eye doctors, both in the UK and the USA, all to no avail. Then I visited a doctor in the UK who had heard of Dr. Maskin and a new procedure, meibomian eye probing. Contacting Dr. Maskins office, I made an appointment and had the procedure done. It was painless and I saw an immediate effect and the eyes have continued to improve. Dr. Maskin is a caring professional at the top of his field. Now, I can continue with my life and move on. If you are suffering like I was. make the call!” William R Carter- Belfast, Northern Ireland “After the procedure, I felt immediate relief. The eye was wet and the burning in the eye was cooled. The eyelid seemed to move more freely over the eye with no friction. My contacts stayed wetter and I did not need to use my re-wetting drops for my contacts as often. The relief so far has lasted for about 2 months.” James Kimbrell Jr. – Seminole, FL “It is now 4 weeks since you performed the meibomian gland probing on my right eye & I am absolutely delighted with the result. No more pain or irritation & I can now resume my social life without the discomfort of placing drops in my eye every hour or so. I was surprised that the actual procedure was quite painless & at no time did I feel uncomfortable. I am so pleased with the result & my husband Ken is in the process of encouraging ophthalmologists in our area to utilize the probe which is now available in Australia. Again thank you so much Dr. Maskin. The long trip from Australia was certainly very worthwhile.” Patricia Jamieson-Queensland, Australia. Order A Starter Kit Today Call 800-637-4346 07 -6 0 40 : Ma skin ™ ) , (2 2m m Probe Starter Kit- (2) m 4m 6m 1) d( n a m es ob Pr 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Steven L. Maskin, M.D. 22 Sagittal View of the Eye 1137 Rev.C 1310 Rev.A AIBA Forceps Lens Loading Forceps Simplicity In Design Makes It Easy To Load Injector Cartridges Fast, With One Instrument! s ep orc F g din Loa e dg rtri r Ca o t c Inje 116: 87-10 1) 2) 1) Grabing The IOL From The Container. 2) Locating The Lens On The Cartridge Crease. 3) 3) Pushing The IOL In Postion On The Fold. 4) Advancing The Folded Lens In Position For The Cartridge Injector. 4) For More Information Contact 800-637-4346 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Study for Libyan Sibyl (Sistine Chapel), Michelangelo 1309 Rev.A AHBA 23 Forceps Inamura* Capsulorrhexis Cystotome Forceps rc ep s ed d 01 8- I 9: 2 4 lo a Bl rr es he xi O pe s ne d Cy st ot om e Fo l os sC e d a l B m na u * ra C ap su • 12mm Formed Blades Designed To Relieve Stress On The Incision. • Unique Direct Acting Jaws Able To Fit Through A Minimal Incision. • Special Cystotome Tips Designed To Open The Capsule In One Maneuver. Micro Gap Between The Blades To Prevent Iris Pickup. • Reusable, Autoclaveable, Made In The USA, Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Mikio Inamura, M.D., Ph. D. 24 1297 Rev.A Mary Magdalene in Penitence, Titian ABBA Forceps 30 3: St ei ne rt DS EK In s e rt ion For ceps Steinert* DSEK Insertion Forceps 0 8- 1 The DSEK (Descemet-Stripping Endothelial Keratoplasty) Insertion Forceps Solve One of the Largest Challenges In This Procedure. After The Donor Tissue Is Folded In Half With A Small Amount Of Viscoelastic Separating The Endothelium, The DSEK Forceps Grasp The Taco On The Stromal Surface With 2 Pins That Hold The Tissue Securely, Yet Minimize Endothelial Crush Injury That Occurs With Other Forceps. Reusable, Autoclaveable, Made In The USA, Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Roger F. Steinert, M.D. Titian, Woman At Her Toilet 1234 Rev.A AHAG 25 Forceps Ambati* DSEK Forceps A b : Am 4 0 8-013 B ati * E DS K Fo e rc ps C D A) Blades Open B) Blades Closed C) Cornea Lamella Removal D) Donor Insertion • Unique Upward-Angled Jaws That Enable Delicate And Precise Control Over Maneuvers Involving Posterior Corneal Manipulation. • Special Gap Between The Blades Prevents Inadvertent Capture Of Descemet’s Membrane. • Ideal For DSEK Or DLEK procedures. • Reusable, Autoclaveable, Made In The USA, Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Bala Ambati, M.D. 26 1250 Rev.C Mantegna, Madonna With Child & Cherubim AJAH Forceps Rhein Insertion Forceps er ti on Fo rc ep s Fo rC ry s ta len s * (For Crystalens*) 0 8- 1 n ei h :R 8 39 s In Low• Special profile Hourglass Jaw Design Holds The Lens Securely During Insertion Through A Minimal Incision. • Mirror Polished Blades Keep The Optic From Being Scratched. • Direct Acting Handle Mechanism Offers Control Over Release Of The Optic. • Wide Jaw Platforms Prevent The Lens From Tilting During Insertion. • Reusable, Autoclaveable, Made In The USA,Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Contact 813-885-5050 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Crystalens is a registered trademark of Eyeonics, Inc. Madam Of Pomegranate, Botticelli 1220 Rev.A AFAG 27 Forceps New Micro Incision Forceps For Bi-Manual Phaco Ti ta ni um In ci si on , m 1. 0m g 23 m s Fo rc ep s, Tu r m .0 ,1 s ep rc Fo s le in ta S n, io is c In 62 :R he in Tu b ul ar 23 g Ca ps u 01 8- in he :R 7 42 la bu is ex rh r o ul ps Ca xis lo rr he xi s N: 242 8-01 g 23 II er n rsh Ke cro Mi ss e l ai n St e rh lor su p Ca mm 1.0 s, p rce Fo ion cis In -2 05 3 • Ultra Micro Shafts For Insertion Through A 1.0mm Incision. • Special Direct Acting Handles For Light-Weight Improved Ergonomics. • Curved Shafts For A More Comfortable Approach. • Recessed Jaws For Improved Sub-Incisional Flap Purchase. • Protective Cap Supplied For Protection Of Jaws During Sterilization. • Reusable, Autoclaveable, Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 28 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com All Instrument Developed In Coordination With Robert M. Kershner, M.D. 1214 Rev.B Paul Gauguin, Woman With Fruit ABAF Forceps Rhein Tubular Capsulorrhexis Forceps in ® Tu b ul ar Ca ps ul or rh ex is Fo rc ep s ,2 3g ,1 .0 m m In ci si on ® 05- Rh 2: 2 36 e • Unique 23g Tube Allows Use Through A 1-Millimeter Incision. • Special Curved Shaft Provides A More Comfortable Approach To The Incision. • Cystotome Tips Are Used To Pinch The Capsule To Initiate And Complete A Circular Tear. • Titanium Handle Is Lighter In Weight For Improved Ergonomic Feel. Ideal For Bi- Manual Phaco Micro-Surgery. • Reusable, Autoclaveable, Guaranteed For Life, And Available For A Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Developed In Coordination With Robert M. Kershner, M.D. 1197 Rev.B Mary Magdalene in Penitence, Titian (1560s) AFAE 29 Forceps Rhein Colibri Capsulorrhexis Forceps 0 in he R : 21 3 5- 2 s xi e h s ep c r Fo • The 0.1mm Pierce Tip Opening I s Desig ned To Pinch A nd Grab A C a p s u l a r F l a p, Without The Need For A Separate Cystotome. rr lo u s ap C ri b i l Co • The 11mm Jaws Are Formed To Help Reach Remote Grasping Positions Without Elevating The Incision. • The Distal Jaws Have Platfor ms, A nd The Proximal Gap In The Blades Help To Prevent Inadvertent Pick Up Of Iris. • The Unique Jaw Structures Makes Grasping A Remote Capsular Flap Easier. • Reusable, Autoclaveable, Made Of Titanium In The USA, & Available For A 30-Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 30 Michelangelo, Portrait of Andrea Quaratesi 1219 Rev.B AFAF ICL Instruments Rowen* White-To-White Corneal Gauges ne or nC O ge Gau a • A Set Of Corneal Gauges Allowing The Exact Outer Diameter Measurement Of A Cornea. • Range Of 10.5mm To 13.0mm, With 0.25mm Increments. • E a sy A nd Qu ick To Use, W i t h One-H a n de d Operation. Simply Dial The Desired Gauge And Place Over A Cornea For Confirmation Of Exact Corneal Diameter. • Re u s a b le, Auto c l ave a b le, M ade I n T he US A , Guaranteed For Life, And Available For A Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Sheri L. Rowen, M.D. 1213 Rev.A Da Vinci, Collage of Vitruvian Man & Study of Female Organs ABAF 31 ICL Instruments ICL C) Instruments 8-0 : 1397 Diamond Knives, Loading Forceps, 2232 : 05 Fixation Rings, Gauges, B) Manipulators & Speculums. F) A) 8-07 150: I) 5079: 05 - 8-1 G) 6 17 5 : L) K) J) 8-013 08 -0 8 M) 8 : O 2& : H90 9 -I )9 400C: N ) 8-0 13 9 6 : P) 8-12115 A) 05-4059 B) 05-2232 C) 8-01397 D) 05-5079 E) 8-07150 F) 05-4060 7 0 01 05 - 14 8 : 51 5 13 -0 8: -509 05 5 0 95: 05 - H) 32 60: -40 : 4059 05E) D) 05 Chu ICL Manipulator- Titanium McPherson, Angled,, 0.12mm Teeth, 3-3/8" w/Platform,Titanium Rhein ICL Retrieval Forceps, 12mm Blades, Angled Jaws 3-D Blade®, 4 Step Handle, 3.0mm Blade (U.S. Patent No. Re. 37,304) Vukich ICL Manipulator Batlle ICL Manipulator- Titanium G) 8-16175 H) 05-5095 I) 05-5098 J) 8-01351 K) 8-08148 L) 05-7001 M) 8-01352 N) 8-01396 Brown ICL Suction Manipulator Rhein Advantage II Diamond LRI Knife Vukich ICL Diamond Blade, 3.10mm Width Collamer & ICL Cartridge Loading Block Kershner Reversible Speculum,Temporal & Nasal Fit, Solid Blades Fine Crescent Fixation Ring,Titanium With Swivel Handle Vukich Collamer & ICL Cartridge Loading Forceps, Cross Acting Vukich Loading Forceps, Direct Acting O) 9 9 - I H9 0 4 0 0 C P) 8-12115 Curved BI-Manual Irrigation Handpiece, .4mm, 23g Rowen White To White Cornea Gauge 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 • 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 1178 Rev.D Girl With Fan, Pierre-Auguste Renoir (1881) AIAG Lens Cutters The Chu* Foldable Lens Cutters (Angled & Straight Models) d gle ut sC le ab 2: 2 45 8-1 8-14522-S: Fold ab t le Lens Being Cu old *F n Le n ,A ter u Ch Chu* Foldab le Lens Cutt er, Straight Fold ces able Lens Cut In 2 Pie Designed To Safely And Easily Cut Foldable Lenses Through A Small Incision Without Having To Enlarge The Incision. Specially Designed To Cut And Remove Even High Diopter Silicone And Acrylic Lenses With Ease With One Instrument. Ideal For Cutting & Explanting Foldable Lenses Which Are Damaged, The Wrong Diopter Power, Or Need To BeExchanged. Available For A 30-Day Surgical Evaluation Without Obligation. Reusable, Autoclaveable, Made In The U.S.A., And Guaranteed For Life. Call 800-637-4346 For More Information 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Designed In Coordination With Y. Ralph Chu, M.D. 1102 Rev.A The Birth of Venus, Sandro Botticelli (1488) BAAB 33 Lens Cutters Brown* Silicone Lens Cutters ne ico Sil n row :B 60 5 4 8-1 ht aig Str , er utt sC n Le • Designed To Safely And Easily Cut Foldable Silicone Lenses Through A Smaller Incision. • Specially Designed To Cut And Remove Even High Diopter Silicone Lenses With Ease With One Instrument. • New Miniaturized Profile Allows Insertion Through A 2.6mm Phaco Incision For Explantation Of A Silicone Lens. • Available For A 30-Day Surgical Evaluation Without Obligation • Reusable, Autoclaveable, Made In The U.S.A., & Guaranteed For Life. Call 800-637-4346 For More Information 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 34 *Developed In Coordination With David C. Brown, M.D. 1187 Rev.A ZIPPORAH, Perugino ABAE Miscellaneous Instruments Henry* Anterior/Posterior Capsule Polisher uct d Pro # 9 22 3 8-1 • Designed To Polish Both The Underside Of The Anterior & Topside Of The Posterior Capsules. • Can Fit Through A Standard 1mm Paracentesis. • Special 1mm Notches On The Anterior Surface For Sizing The Capsulorrhexis. • Unique 5mm Notch On The Anterior Surface For Quick Reference. • Autoclaveable, Made Of Stainless Steel In The USA, Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Call 727-209-2244 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Michael M. Henry, M.D. 1318 Rev.A Mary Magdalene in Penitence, Titian AEBB 35 ap su le C r :S Po he lis phe Sh he rd e Ca ph r- * ps erd D An ul ou t * eP A bl eri ol nte e or ish rio En / er r/ -R Po de Po igh st d ste e t rio ri r o or er- /Pos t Le ft erior lish 8-1 32 15 :S he Ca pherd psu *A le Po nteri 8- 13 21 4: 8- 13 21 5- D Miscellaneous Instruments Capsule Polishers r rio e st Po r/ io r r te he An lis ** Po y nr le He psu : 9 Ca 22 13 8 Call 727-209-2244 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With John R. Shepherd, M.D. **Developed In Coordination With Michael M. Henry M.D. 36 1322 Rev.A Raphael, Fresco of Adam and Eve BBBB (For Intralase & Retreatments) Dis Sp tal at ul a i ng rat b i *V ar t tew S : 77 8-161 K SI LA a Sp Miscellaneous Instruments Stewart* Vibrating LASIK Spatula e et pl m Co a, l tu • Unique Oscillating Distal Spatula Makes Penetrating And Lifting Adherent LASIK Flaps A Breeze. • • Special Mirror-Polished Spatula Is Flattened To Easily Penetrate The Interface. Removable/Replaceable Spatula Tip For Easy Sterilization. Replaceable Battery. • Ideal For Intralase Flaps Or Stubborn L A SIK Retreatment Flaps, And Quick & Easy To Use. • Other LASIK Spatula Tip Configurations Available Upon Request. • Reusable, Autoclaveable, Made In The USA, & Available For A 30-Day Surgical Evaluation Without Obligation. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With W. Colby Stewart, M.D. 1229 Rev. B Young Woman at Her Toilet, Titian BCAG 37 e nt pl ac em Re Miscellaneous Instruments Johnston* LASIK & LASEK Titanium Applanator a Fl p An ter io ea orn fC r View O 05-7003: Johnson te Af r SIK LA or at n la pp A p Fla a Tit u ni • m Designed To A p p l y E q u a l Outward Posterior Pressure To The LASIK Flap For E ve n Eg re ss O f Fluid To Consistently Enhance The Seating & Healing Of The Flap To The Stromal Bed. Also, Designed To Apply Posterior Pressure To Ephthelial Cells During LASEK For More Even Distribution Of Cells. • Special Concave Posterior Lens Surface Designed To Be Pressed Onto The LASIK Flap To Outwardly Flatten The Central Cornea To Resolve Striae, Enhancing Centration And Control Over The Distribution Of Applanated Tissue. • Unique Transparent Applanation Lens Offers Clear Visualization Allowing Full View Of The Applanated Surface Through A Microscope. Special Convex Anterior Lens Surface Eliminates Reflection, And Has A 9mm Orientation Ring For Perfect Centration And Confirmation Of The Applanated Surface. • Easily Applied To The Flap Without Interference From The Speculum, Eyelids, Or Nasal Bridge For Unencumbered Access Around The Clock. Designed To Prevent Striae With A Minimum Of Time & Surgical Skill. • Ideal For Treating Post-Operative Striae, And Refloating & Repositioning The Flap To Insure Consistent Post-Operative Optical Clarity And 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Robert M. Johnston, M.D. 38 The Birth of Venus (detail), Sandro Botticelli (1485-88) 1093 Rev.D AJAG mm 10.4 , Phaco upil Dilator 8-09133-A: Brown* P Miscellaneous Instruments Brown* Pupil Dilator System i on Incis Exp ing Pupil Be d de an ion ncis ort I P e d i or, S l Dilat 8-09133-B: Brown* Pupi This System Is Designed To Manually Dilate A Small Pupil With Greater Safety And Efficacy. The Bimanual Technique Maximizes Safety By Allowing The Iris Hooks To Be Advanced Parallel, Rather Than Perpendicular, To The Plane Of The Anterior Capsule, Thus Minimizing The Risk Of Inadvertent Capsule Tears. Pupil Stretching Is Also Maximized, With The Pupil Dilator (809133-A) Introduced Through The Phaco Incision And Stretching The Pupil Into A Cat's Eye Shape When The Push/Pull Mechanism Is Opened. The Side Port Pupil Dilator (8-09133-B), Introduced Through The Paracentesis, Then Pushes The Iris To The Opposite Side Of The Eye, Achieving An Equilateral Triangle And Maximal Three-Point Stretching. Autoclaveable, Made In The USA, Guaranteed For Life, And Available For A 30 Day Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 1165 Rev.C 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Self Portrait, Rembrandt AGAF 39 Miscellaneous Instruments 2 40 -2 3 5 0 -S N 0 -S N Grasping ep rc Fo ep rc Fo s 01 01 s New 25g Vitrectomy Instruments 01 -2 6 Grasping N 1 0 -S s ep rc Fo g Graspin 01 N 20-S -30 s ep orc F Grasping 01 -3 0 3 0 -S N s p ce or F Grasping SN 60 -3 0 01 ps ce or F g Graspin N 0 0 -S -4 2 01 Call 800-637-4346 For More Information On Our 25 Gauge Grasping Forceps And Scissors. s sor Scis 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com All Rhein Products Meet The Requirements Established Within The European Union 40 Background By Michelangelo 1072 Rev.F ACBA O ips Closed tal T se d Bo t h Dis et s ff Miscellaneous Instruments Sabet* Pterygium Flap Maintainer en l Offset Dista o cl s p Ti tal Offset Dis s Tip O p er in a t ain M p Fla m giu ery t P et : Sa b 7 2 2 3 1 8 • Pterygium Surgery Made Simple! • Enhances Proper Orientation Of Difficult Conjunctival Grafts During Pterygium Surgery. 5mm Spread. • Helps With The Intraoperative Management And Manipulation Of Free Conjunctival Flaps. • Reusable, Autoclaveable, Made In The USA,Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Sina J. Sabet, M.D. 1267 Rev.A Head of St. Anne, DaVinci ACAI 41 at ul a Sp & Fo rc ep s Miscellaneous Instruments Pfister* Suture Adjustment Set For Astigmatism 0 8- 1 r* te fi s P 4: 12 PK P re tu Su dj A t en m t us P Ci . O .R 8- 07 1 51 :P fis te r * PK P Su tu re A dj us te r U se d In 15 07 8- S ed Us Ou e ist Pf 2: PK r* re u ut r he nc r Fo nt tie a tp 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Email: [email protected] • Website: www.RheinMedical.com * Developed In Coordination With Fredrick T. Pfister, M.D. 42 The Thinker, Rodin BCAG Miscellaneous Instruments Statim 7000 High Throughput Capacity Autoclave in tch a B Pouch ss Instrument Ca e s t te g • Cycles In 12 Minutes. • A Unique Drying System That Evaporates Moisture In Minutes. • Removable Water Reservoir System That Uses Just Tap Water. • Direct To Drain Capability. Water R ir rvo e s e • Wi l l H o l d Two 8”x11” Instrument Trays With Up To A 10 Pouch Capacity Each. • 02-710 0: Stati m 7000 02-710 With Pr 1: Stati inter m 7000 Withou t Prin M o d u l a r Design For Easy Use & Maintenance. FOR MORE I N F O R M AT I O N PLEASE CALL 1-800-637-4346 ter 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Woman, Michelangelo 1276 Rev.B Rev.A 1272 AJAI AFAI 43 Miscellaneous Instruments The Sabet* Lenticular Safety Net (For Supporting A Dropped Lens) c ra et R O n pe d te et sk Ba et sk a B t i nt e *L ar l cu y et af Ne S et : 28 4 01 b Sa 8- • Designed To Hold & Support A Dropping Lens To Safely Allow Anterior Vitrectomy & Phacoemulsification To Continue. Can Support Multiple Fragments Simultaneously. • Provides The Length Of A Cyclodialysis Spatula To Reach Into The Vitreous Cavity To Salvage Lens Fragments With One Instrument. • A 23g Tube Fits Through A 1mm Paracentesis Or Pars Pl a n a Incision, A nd When Opened Inside The Eye, Provides A Large Surface Area For Fragment Support. • Thin A n d S t u rd y W i re s M i n i m i z e T r ac t i o n I n T h e Vitreous W h i l e S u p p o r t i n g A Nu c l e u s . A d d i t i o n a l S a fe t y N e t B a ske t s A re A l so Av a i l a b l e ( Product # 8-01428-B). • Reusable, Autoclaveable, Made In The USA, & Available For A 30-Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 44 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 1217 Rev. B *Developed In Coordination With Sina J. Sabet, M.D. Leonardo Da Vinci, Mona Lisa AFAF Miscellaneous Instruments Rousseau* Chin-Lift Stabilizer 815 25 5 :R ous sea u* Chin-L ift Stabilizer • Maintaining The Proper Patient Position During Surgery Is Key To Both The Flow And Outcome Of Ophthalmic Procedures. Not Every Patient Is Able To Maintain Consistent Head Position On Their Own, And Slight Movements Can Compromise The Procedure, Or Necessitate Discontinuing Treatment To Reposition The Patient. • The Chin-Lift Stabilizer Removes The Guess Work Associated With Hand Held Markers, And Eliminates The “DRIFTING” That Occurs During Surgery, Allowing The Surgeon To Maintain Head Position, Ensure Accuracy, And Achieve Results. • The Ophthalmic Chin-L ift Is F ully Adju stable To Accommodate A ll Patient s, A nd It s Features Include A Telescoping Chin A r m, A nd Adjustable Padded Over-The-Shoulder Harness. The Shoulder Harness Is Made Of A Malleable Material That Allows Quick And Easy Contouring To Any Patient. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Paul B. Rousseau Jean Goujon, Naiade Fra Le Braccia BBAF 45 Miscellaneous Instruments Tetz* Enclavation Spreader (For Verisyse/ Veriflex Lenses) 3: 39 1 0 8- er ad re p S on ati v la nc *E z t Te ) es ns e xL ifle er V e/ ys ris e rV (Fo A B C The Spreader Is Designed To Be Placed Inside The Haptics (A) Of The Verisyse Or Veriflex Lens. The Button Is Pushed Forward, Causing The Blades To Separate I n s i d e T he H ap t ic s . ( B ) T h i s A llows The L ens To Be Placed Over The Crease In The Iris. Once In Place, The Button Is Retracted, Allowing The Haptics To Be Rela xed I nto Posit ion, (C) Fixating The Lens Onto The Iris.(D) The Instrument Is Reusable, Autoclaveable, Made In The USA, Guaranteed F o r L i f e , & Available For A 30 Day Surgical Evaluation Without Obligation. D Call For More Information 800-637-4346 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Manfred R. Tetz, M.D. 46 1257 Rev.A Virgin Enthroned, DaVinci AEAH 9: 40 4 8-0 H ar nip a *M n ma er rk or t ula an rm a :H a *C e rh lor u ps Ma xis Miscellaneous Instruments The Harman* Manipulator & Capsulorrhexis Marker 7 11 12 8- The Harman* Manipulator (P r o d u c t # 8-04409) Has A Mirror-Polished Distal Tip Shaped Like An Olive, Which Is Ideal For Sweeping Nucleus Fragments Toward A Phaco T ip, Ma k i ng Cle a r Lensectomies & Nucleus Manipulation A Breeze. The Harman* Capsulorrhexis Marker (Product #8-12117), Is Designed To Place A 5mm Circle On The Anterior Cornea. The 5mm Optical Zone Assists For Accurate Centration Of The Capsulorrhexis & Placement Of A Multifocal & Accommodating IOL. The Marker Has 2 Elevated Opposing Radials With An 11mm Spread For Small Corneas, And 2 Elevated Opposing Radials With A 12mm Spread For Large Corneas. Only The 5mm Center OZ Touches The Cornea. Reusable, Autoclaveable, Made In The USA, Guaranteed For Life, Available For A 30-Day Surgical Evaluation Without Obligation. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Vermeer, Girl With The Pearl Earring 1233 Rev.C AFAH 47 Miscellaneous Instruments Roholt* Haptic Adjuster ter tic : 28 2 13 8- * olt h Ro p Ha s dju A • Designed To Adjust Haptic Curvature Of A 3-Piece Intraocular Lens, Changing Its Overall Length For Improved Centration. • Ideal For Aspheric Optic And Multi-Focal Lenses Where An Asymmetric Capsular Bag Causes Mild Decentration. • The Overall Length Of The Lens Can Be e en Op r ste Adju d Increased Or Decreased Approximately 0.5 mm, Depending Upon Where The Haptics Are Adjusted. Also Ideal For Straightening A Bent Haptic, And Stabilizing A Haptic While Performing Suture Fixation. • Unique Micro Tip Dimensions Provide Easy Manipulation Within The Anterior Chamber, With A Sliding Shaft To Reduce IOL Movement During The Procedure. • Reusable, Autoclaveable, Made In s lo rC e t s Adju The USA, Offered For A 30 -day Surgical Evaluation Without Obligation. ed r Sho Ha i ng n te ic pt t Leng 48 ti c Call 800-637-4346 For More Information. in hen g p Ha 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Philip C. Roholt, M.D. 1272 Rev.B Madonna of the Goldfinch, Raphael AFAI Multi-Use Manipulators • Designed To Safely Spin, Chop And Backcrack A Nucleus Using Less Phaco Time. To Backcrack, Simply Place The Wand Beneath The Nucleus And Lift While Applying Posterior Pressure With The Phaco Tip For A Clean And Safe Nucleus Fracture. ss le in ium a t n , S ta ht , Ti g i t ra gh St rai : t 14 : S 71 55 0 0 8- -4 05 is ta l Ti p • Av a i l a b l e In Curved, Angled And Straight Shaft Models For Unlimited Access Around-The-Clock. Miscellaneous Instruments The Original Connor* Wands s es nl ium i ta an , S Tit d ve d, ur rve : C Cu -C : ss 14 5-C le m 1 5 n 7 i iu 0 0 a 8- 5-4 St itan , 0 d T le d, ng gle :A n A A 4- -A: 1 1 5 07 05 8- 5-4 0 rd D a • Perfect For Dialing Intraocular Lenses nd a t In And Out Of The Bag. The Wand Is S Also Used To Protect The Anterior Capsule, Posterior Capsule, And Iris During Phaco And Cortical Cleanup, As Well As Providing Counter Traction In The Paracentesis For Improved Fixation During Construction Of The Phaco Incision, Capsulorrhexis, And Lens Delivery. • Designed For Manipulating And Sweeping Nucleus Fragments Toward A Phaco Tip In The Central Safety Zone For Safer Emulsification, With Less Stress To The Zonules. Safely Lifts And Flips Nuclear Fragments And Epinuclear Bowls Off Of The Posterior Capsule. • Reusable, Autoclaveable, Made In The U.S.A., Guaranteed For Life, Available For A 30-Day Surgical Evaluation Without Obligation. Go To www.rheinmedical.Com To View The Instructional Video. Call 800-637-4346 For More Information Or To Order Today 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com * Developed In Coordination With Christopher S. Connor, M.D. 1312 Rev.B Santa Anna, Leonardo Da Vinci ADBB 49 5 3 .2 5 4.0 4 .7 Refractive Geggel* Corneal Transplant Markers nt pla Bite Ru ure Sut 3.2 5 4.0 5 n Cor 4.7 gel Geg 07: 1 2 8-1 ns Tra eal 4 r, 2 rke Ma ng nni er, ark 16 Bite R ure ut gS in unn M lant nsp a • One Instrument Easily r lT Marks Both The Recipient And nea r o lC Donor Corneas In A Single Step. gge : Ge 2 1 21 • Simply Suture The Dots To Achieve A Precise And 8-1 Rapid Running 16 Or 24 Bite Anti-Torque Closure. • Special Center Pointer Provides Exact Alignment For Perfectly Symmetrical Suture Placement. •Easy To Use, Offering Postoperative Adjustment Opportunities To Minimize Astigmatism. •6.5mm Inner Diameter •Also & 9.5mm Outer Diameter Designed For A 8mm Trephine Opening. Allows Running Suture Placement For Trephine Openings From 7.75mm To 8.25mm. •Gentian Violet Marking Pens (Product # 07-8000) Available Upon Request, And The Marker Includes A Complimentary Instructional Video. •Reusable, Autoclaveable, Made In The U.S.A., Guaranteed For Life, And Available For A 30 Day Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information 50 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Designed In Coordination With Harry S. Geggel, M.D., Virginia Mason Medical Center, Seattle, WA 1201 Rev.A Pietá, Michelangelo (1499) AHAE Refractive Verges* Suction PRK Amoils Brush Guides m 8m e, id ils o sS Am u Br Gu P 9m m 1 18 6 -1 ge er V : n io t uc RK sh V er ge s Su ct io n PR K Am oi ls Br us h Gu id e, 8 • 8- 16 18 2: Special Suction Holds The Globe Still And Prevents The Brush From Swimming Away F r o m T h e Ta r g e t . • Two Sizes Accommodate All Of The Brush Diameters. • Reusable, Autoclaveable, Made In The USA, Guaranteed For Life, And Available For A 30Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Carlos Vergés, M.D. Angleo Con il Cartiglio, Bernini 1280 Rev.A ABAJ 51 Refractive IntraLASIK Instruments eau* 8-16173: Rouss SIK aL A Intr p Fla er ead Spr • Special Reverse-Action Forceps Design With Spreading Spatula Tips That Mimic Corneal Curvature. Designed To Facilitate The Spreading & Lifting Of Corneal Flaps Created With The IntraLase TMFS Laser System. • The Spatula Tips Of The Forceps Are Designed To Facilitate AccessUnder The Corneal Flap. Once Access Is Achieved, The Cross-Action Forceps Design Allows The Surgeon To Apply Equal Opposing Force To Separate The Micro - Adhesions Which Can Otherwise Interfere With The Smooth Lifting Of The Flap. • Designed To Be Used Specifically For Lamellar Flaps Created With The IntraLase TMFS Laser System, And For Retreatment Flaps Originally Created By Mechanical Microkeratomes. Optimal Results Are Experienced With Flaps Measuring 100+ Microns. ent el* ib 2: Se 17 8-16 K LASI Intra Flap r& Lifte eatm Retr ula Spat • Ideal For IntraLase Flaps, As Well As Retreatment For Flaps Originally Created By A Mechanical Microkeratome. • Unique Design Maximizes A Surgeon’s Ergonomic Mechanical Advantage By Eliminating The Induced Torque Inherent In Conventional Flap Lifters. • Unique Central Pivoting Technique (Described In Instructions & Video) Provides Increased Mechanical Advantage Over Conventional Flap Lifters To Separate More Adherent Flaps. Dimensions And Torsional Rigidity Are Optimized To Transmit Surgeon Force Efficiently With Minimal Artifactual Flex. • Parabolic Shaped Tip Allows Easy Initial Insertion Under Flap The At Hinge. The Opposite End Of Instrument Has a Rounded Tip Designed Specifically To Open The Gutter And Adjacent Flap Interface At Both Ends Of The Flap Hinge To Further Facilitate Easy Initial Insertion Of The Flap Lifter. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Paul B. Rousseau & Barry S. Seibel, M.D. 52 1176 Rev.B All Rhein Products Meet The Requirements Established Within The European Union Male Nude Study From Back , Michelangelo (1497) AJAD Refractive el W l Huang* LASEK Instruments n. tio l na el phi W e m l Tr 8m lia & the n pi io ns e E te bl n. Ex nda io m pe at 8m De l hin l 7 0 e & /. W rep w asy m lT E ne hi or 9m elia p F e & ith Tr ade n l K io Ep SE p B ns le e LA har t ab m -S Ex nd 5m or m pe 7. Raz e m g 3 D n d ua rde 08 & /. y : H ua w as 05 G E e 0 n r 17 hi Fo 8ep e Tr lad K B SE rp LA ha m r-S 5m zo 8. Ra ng ed a u rd : H ua 06 G 0 17 8- G 81 ua 700 rd 7 ed : H R ua az n or g 9 -S .5 ha m rp m B LA la de SEK Fo T r rep Ea h sy ine & w D /. 8-1 ep 09 70 en 0m 08 da m :H ua bl ng e Ex Ep Ep te ith ith ns eli al el ion LA ia SE lT & K re 10 Ho e, ph m Ve in m rsa at W tile io ell Ho n. eF or Th eE nti re Ep ith eli al Pe eli ng 91-8 Pr 030: oc Hua For es ng L Quic s. A k Irr SIK Cann igati on & ula, 2 Po Repo rts, sitio 23g, ning Mids . ize C annu la ep Tr ne hi Call 800-637-4346 For More Information. 1159 Rev.A 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With David Huang, M.D., Ph.D. All Rhein Products Meet The Requirements Established Within The European Union Fontana di Oceana, Giambologna AHAE 53 Refractive Femtosecond Spatulas s les 72 61 1 8- l*, ibe e :S in Sta um ani *, Tit eibel 07: S 5-70 0 s nles eib e*/S eg -L: L 172 Stai el*, s t s 81 61 73 : Ro u 8-16 ,S u* a se es nl ai less e s*/S ta Stra 178: 8-16 in , Sta ibel* s ai St ib Se */ ler , el* es nl ex :W 9 17 16 8- Call 727-209-2244 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 54 *Developed In Coordination With Barry S. Seibel, M.D., Barbara Lege, M.D., Paul B. Rousseau, Byron A. Stratas, M.D., & Stephen A. Wexler, M.D. 1323 Rev.A Lucas The Elder, Venus & Cupid BBBB Refractive Seibel* IntraLase Flap Lifter & Retreatment Spatulas nt tme re a Ret n & o i r t ra ifte net ap L r Pe e Fl asie Las E a r r t Fo In Tip 8 -16 2: Seibel* I 17 stal r Di e m Slim S ula pat a Sp tu la a , St it ,T an iu inle ss m t en tm s a re e s L et R or F & ip er ft l T Li ta s p i a Fl d D se pe a a n • Ideal For Both IntraLase Flaps, As aL Sh tio tr I n l l e t t ra Well As Retreatment With Any Flap, e II u n * B e el Whether Originally Created By IntraLase ed e P ib Se und siv : Or A Mechanical Microkeratome. 7 s o 0 0 e R 05-7 gr • Unique Design Maximizes A Surgeon’s Ergonomic Ag Mechanical Advantage By Eliminating The Induced Torque Inherent In Conventional Flap Lifters. • Can Be Used Utilizing A Central Pivoting Technique (Described In Instructions And Video) To Further Increase Advantage Over Conventional Flap Lifters With More Mechanical Adherent Flaps. • Dimensions And Torsional Rigidity Optimized To Transmit Surgeon Force Efficiently With Minimal Artifactual Flex. • Parabolic Shaped Tip Allows Easy Initial Insertion Under Flap At Hinge. The Opposite End Of Instrument Has A Short Rounded Tip Designed Specifically To Open The Gutter And Adjacent Flap Interface At Both Ends Of The Flap Hinge To Further Facilitate Easy Initial Insertion Of The Flap Lifter. • Available In Two Models, 8-16172: Stainless, And 05-7007: Titanium. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Barry S. Seibel, M.D. 1215 Rev.A Giorgione, Judith ADAF 55 Refractive The New Rousseau* Slit-Lamp Mounted Axis Marker (With Blunt Tips) ou n t 8-15254 Unm oM yT ead R , d unte 8-15254 Mo k ar Ax m Fro ed tSli La p m is l-Tip Slit Lamp Dua M au* e s s ou Rou : nt 4 52 5 ed 1 8 Ax is Marker • Designed To Mark The X & Y Coordinates At The 6 & 9 O’clock Positions For Accurate Axial Alignment. 11mm Inner Diameter & 15mm Outer Diameter Blunt Axis Marks Cover The Limbus. • Removes The Guess Work Associated With Hand-Held Markers By Mounting The Device To Any Applanation Tonometer Tip Slit-Lamp Housing To Ensure A More Perfect Mark. • Etched Calibration Marks Align With Most Standard Tonometer Housing Units To Ensure Exact Horizontal Alignment. • The Device Can Be Rotated To Specific Etched Degree Marks To Allow For Marking All Astigmatic Axes. • Reusable, Autoclaveable, Made Of Stainless Steel In The U.S.A., A nd Av a i lable For A 30 -Day Su rg ic a l E v a luat ion W it hout Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 56 *Developed In Coordination With Paul B. Rousseau 1210 Rev.B Rembrandt, Self Portrait AGAG Refractive Davis* LRI Marker r io Po st er cs Ar ne i L w ie O a fM r rke m m 2 /1 1 /1 0 ,1 s e re eg An te rio r V s rc A r, ke I s : 8 11 i av LR , 30 45 & 60 D 60˚ ar 45˚ M 30˚ D 12 rk s 8- l ea rn o C a M • Simple & Easy To Use, With 30, 45 & 60 Degree LRI Arc Indicators. • 10, 11, & 12 Millimeter Diameters Arcs On This Marker Encompass All Corneal Diameter Sizes. • One Marker Can Be Used For The Vast Majority Of LRI Incisions. • Reusable, Autoclaveable, Made In The USA, Guaranteed For Life, Offered On A 30-Day Surgical Evaluation Without Obligation, & Provided With A Complimentary Instructional DVD. Contact 800-6374346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Andrew P. Davis, M.D. 1268 Rev.A Madonna of Pomergrante, Botticelli ADAI 57 37 Refractive R ad ial s Ruminson* LRI Marker & Seibel* LRI Diamond Knife Set gs 7m m I.D . & 14mm u Ga 360º Any Axis e& ug tin et S ge Ga tic As n* o ins 3: 11 r. rke Ma ma tig m Ru .5 0 m m 2 8-1 g in rk a .M O.D T o ns io n e ct tra Re ll Fu on ti ec t ir u D fC O te Ex 05 0 -5 39 :S ei l* be LR I D ia m on d K ni d • 8-12113: Ruminson* Ast ig ma t ism Gauge Can Be Set For AK’s, LRI’s Or Peripheral Corneal Incisions At Any Degree Around The Globe. fe Single Or Paired AK’s, LRI’s •OrMarks Peripheral Corneal Incisions 360 Degrees, At Any Axis. • Cut-Outs At Each 90 Degree Meridian Allow Visualization Of The Limbus For Easy Centering On The Eye. 05-5039: Un iq ue I n-L i ne M i r ro r-Pol i she d D ou ble •Footplates Are T urned 90 Degrees To Allow Unobstructed Visualization Of The Diamond Blade While Incising T issue. Pre-Set Blade Extension Settings Of 0.5mm, 0.55mm, 0.6mm, Including Full Retraction And Full Extension. • Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Wallace E. Ruminson, M.D. And Barry S. Seibel, M.D. 58 1263 Rev.A Madonna with Child and Cherubim, Mantegna BBAH Refractive Seibel* Gravity Fixation Ring 08 -70 05 m niu ita T , In ing R n tio ixa F ity rav G * l be Sei • Gravity Feature Allows The Ring To Remain Parallel To The Iris/Limbus Plane Regardless Of Handle Inclination, Maximizing Ergonomic Ease Of Placement With O nly One Hand. • C o m p a c t D e s i g n A l l o w s I m p r o v e d A c c e s s To Speculum Openings, Offering A Wider Range Of Globe Movement For Optimum Incision Placement Or Red Reflex Enhancement. • Large Ring Gap Maximizes The Potential Length For Peripheral Corneal Relaxing Incisions, While Simultaneously Giving Greater Than 180° Of Limbal Contact To Optimize Stabilization And Manipulation Of The Globe. • Engagement Pins On Bottom Of Ring Optimized For Positive Globe Control As Well As Minimizing Stress To The Conjunctiva. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Barry S. Seibel, M.D. Special Thanks To Spencer P. Thornton, M.D. & I. Howard Fine, M.D. 1320 Rev.B Michelangelo, Lamentation AIBB 59 Refractive Dell* LRI Markers 12 8- 8: 10 Co a l M a rk rne o :C 11 1 2 -1 a rne ism am ogr m o sN The Gill , For r e k Mar l M a rk -5: 8-12111 Del l* ig m A st at i s k ar k t gma Asti * l l De 8 Co -5: 8-12108 ar lM a rne a mM rn Co T he N ic h a m , For r ke r lM ea o in N gr mo am • 8-12108: Designed To Be Used With The Gills Nomograms. 6mm And 8mm Chord Length Radials Placed On The Cornea For Making Limbal Relaxing Incisions. • 8-12108-5: Designed To Be Used With The Gills Nomograms. 6mm & 8mm Chord L ength Radials Placed On The Cor nea For Making Limbal Relaxing Incisions.5mm Inner Circle Assists In Sizing A Precise Capsulorrhexis For The Crystalens Implant. • 8-12111: Designed To Be Used With The Nichamin Nomograms. 40, 60, & 80 Degree R adials Placed On The Cornea For Making Limbal Relaxing Incisions. • 8-12111-5: Designed To Be Used With The Nichamin Nomograms. 40, 60, 80 Degree Radials Placed On The Cornea For Making Limbal Relaxing Incisions. 5mm Inner Circle Assists In Sizing A Precise Capsulorrhexis For The Crystalens Implant. • A l l Fo u r D el l M a r k e r s A re D e s ig ne d To M a r k A C o r ne a Fo r P l a c e m e n t O f Limbal R e l a x i n g I n c i s i o n s & E x a c t P l a c e m e n t O f To r i c L e n s e s . R o t a t i n g B ez e l A l i g n s Radials In The Proper Meridians. • R e u s a b l e , A u t o c l a v e a b l e , M a d e I n T h e U. S . A ., G u a r a n t e e d F o r L i f e , Av a i l a b l e F o r A 3 0 - D ay Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information 60 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com * Developed In Coordination With Steven J. Dell, M.D. 1202 Rev.C Moses, Michelangelo AJAI Refractive l ue ig M * ado on d l a UAF LASIK Mar ke r 8-12 11 4: M Miguel Maldonado* Undersurface LASIK Instruments Cor Anteri iew or V M Of ar ke rk iew or V O fM ar ke r osterior Ablatio n IK P Pl a 6174: Mig 8-1 ue m or tf lM a lM r Po s t e r i AS *L o d na do l a nea w Vie Anterior Pl Of r Po s t e r i o at fo rm a f Fl View O w Vie Of a Pl t fo n pO Pl at fo rm rm 8-12114: Has Two Radial And Two Pararadial Evenly Distributed Marks, Providing Four-Point Alignment Of The Lamellar Flap To Insure Exact Repositioning. The Pararadial Marks Prevent Inadvertent Placement Of A Free Cap Epithelial-Side-Down. 8-16174: Combination Fixation Ring With A Platform Provides A Physiologically Spherical And Low-Reflective Smooth Surface To Place A Reflected Flap For Undersurface Laser Ablation Of The Posterior Flap. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 1193 Rev.C Renoir, Girl With Fan (1881) BAAE 61 Refractive Dell* Toric Axis Markers Precise Alignment For Correct Toric Axis Placement, From Upright Through The Supine Position. ting Bezel With Rota ns Marker d Toric Le Position xe ne Fi l pi el Su D In 8-12119: n Patient Is Used Whe ith ker W nt Mar ens en Patie L ic l Tor d Wh wive zel Use n ell S e sitio : D tating B o 0 P 2 1 ht Ro 8-12 Uprig n I Is 8-12119: R o t a t i n g I n n e r Bezel Automatically Orients Marks For The Placement Of A Toric IOL In The Correct Meridian. While The Patient Is Upright, An Orientation Mark Is Placed Vertically On The Conjunctiva. In Surgery The Rotating Inner Bezel Is Set To The Desired Meridian. While The Instrument Is Positioned So That The Vertical Conjunctival Mark Is Aligned With The 90 Degree Position On The Outer Bezel Of The Marker. The Marking Blades On The Undersurface Of The Instrument Will Automatically Place A Mark In The Correct Meridian When The Cornea Is Indented. 8-12120: Weighted So That Correct Horizontal Orientation Is Assured. Rotating Inner Bezel Automatically Orients Blades For Corneal Marks For The Placement Of A Toric IOL In The Correct Meridian. Designed For Use With The Patient Upright Immediately Prior To Surgery, The Inner Bezel Is Rotated To The Desired Meridian, And The Cornea I s I n d e n t e d . Th e Ma r k i n g B l a d e s O n Th e Un d e r s u r f a c e O f Th e Instrument Will Automatically Place Marks In The Correct Meridian. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com*Developed In Coordination With Steven J. Dell, M.D. 62 Moses, Michelangelo 1269 Rev.C AGAJ Refractive Dell/Donnenfeld* LRI Marker 8- 12 11 1- D D el l/ D on ne nf el d* LR IM ar ke r (Used With The Donnenfeld* Nomograms) • One, Two & Three O’Clock Radials Are Placed On The Cornea, With A Central Mark For Toric Lens Alignment. • Rotating Bezel Is A d ju s t a b l e For The Desired Axis, And Able To Be Inked. • A nte r i or N u m b e r s M a ke S e t t ing T he Marker Quick And Easy. • R e u s a b l e , A u t o c l a v e a b l e , M a d e I n The USA, And Offered For A 30-Day Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Steven J. Dell, M.D. & Eric Donnenfeld, M.D. 1300 Rev.A Angel With Thorn Wreath, Bernini ADBA 63 Scissors Got Scissors ? i de ,W ight R ” - 1/ 4 cott 5 : West 8-03111 , es ps Ti ai gh t ad Bl all m S d, rve Cu , ” s4 sor Scis : I r is 3 3 3 3 8-0 p ar Sh Ha ps Ti nt u l ,B l es nd s es a ann l s/ V 3: Gil 8-0350 m 10 s, or s s Sci tr ,S m Gi 8-03507: as nn Va h s l e lls/W es la d B m 11 d la B 5m m iss Sc gl An s, r o , ed m ss , 4” S e at rp Po in t s 8- S ci nas Van : 8 0 03 5 / 3-1 or s ic el D , rp ha iss or s Sc g , An /4” s 3-1 ha ,S eb ul ki ng a : Vann 8-03509 de Si To l ed n r-Ara 8-03617: Mansu & ng sti rve a H ft Gra er Pt iu yg m D C a l l 8 0 0 - 6 37- 4 3 4 6 F o r M o r e I n f o r m a t i o n O n O u r Complete Selection Of High-Quality Ophthalmic Scissors. 64 1248 Rev.A 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com The Creation , Michelangelo AEAG Scissors bu lk in g Sc is so rs Mansur-Aran* Graft Harvesting & Pterygium Debulking Scissors af Gr g in st e v ar H t & e D n • D e s i g n e d To R e d u c e ra -A r Procedure Time In Pterygium u s n Surgery. Ma : 7 1 8-036 • Excellent Dissection Capabilities, Especially For Tough Fibrous Tissue At The Pterygium Base. • Offers Precision Separation Between Conjunctiva And Excised Fibrous Tissue. • Sharp Inner Blades For Rapid Cutting Of Fibrous Tissue. • • Unique Ergonomic Rounded Blade Tips For Precision Graft Harvesting. • Reusable, Autoclaveable, Made In The USA, Guaranteed For Life, And Available For A 30-Day Surgical Evaluation Without Obligation. Special Millimeter Marked Blades For Measuring Donor And Recipient Sites. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Arnulfo V. Mansur, M.D. & Alberto J. Aran, M.D. 1222 Rev.B Giorgione, Judith AIAF 65 Single-Use Instruments Single Use Solutions • New Lower Prices • Better Value • Exceptional Quality C -50 10 , s la nu an Pr ec ox rB Pe On ing d n pe De d ging Nee cka Pa s. rs. pea S 5 s of uche o P 20 Box, Cellulose Eye Spears, 100 Per isi o nS tai nle ss Bla de Lin e, M an y Con figuratio ns , 6 Per Box. Call 800-637-4346 Today, For A Complete FREE Catalog And FREE Sample And Use It Tomorrow!* 3360 Scherer Drive, Suite B. St.Petersburg, Florida 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com * Overnight Shipping Charges Apply. 66 Girl-with-a-Pearl-Earring, Vermeer 1281 Rev.B AEBB Single-Use Instruments New Rhein® Eco’s™ M C an ho pp e rs ip ul at or s Now Available Sterile & Non-Sterile ps Ho lde rs e rc Fo Sp ec ul u m s Ne ed le sors Scis Ready-To-Use, High-Quality Stainless Steel Rotators, Manipulators, Choppers, Forceps, Needle Holders, Scissors And Speculums. Packaged 6 Per Box. Now Available Sterile & Non-Sterile. Contact 800-637-4346 For A Complimentary Catalog. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com Eco™ Is A Trade Mark Of Rhein Medical, Inc. All Rights Reserved 1226 Rev.B Mantegna, Madonna with Child & Cherubim AHAG 67 Single-Use Instruments New Blade TechnologyFrown Blades o ac ed gl m n ow Fr An Ph e ad Bl 5m . :2 -F 50 2 -0 03 o ac mm ed gl 2.5 m n ow Fr An Ph e ad Bl 5m F: 5- 6 02 6 2. - 03 o ac m 5m 2.6 ed gl m n ow Fr An Ph e ad Bl 8m . :2 -F 80 2 -0 03 mm co a 2.8 d e gl m n ow Fr An Ph e ad Bl 0m . :3 F 0- 0 03 - 03 m m 3.0 o ac ed gl m n ow Fr An Ph 2m -F 20 3 -0 03 mm 3.2 68 . :3 Single-Use Stainless Blades With Aluminum Handels. Contact 800-637-4346 For A Free Sample. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com 1209 Rev.A St. Sebastian, Titian e ad Bl BBAE Speculums Kershner* Reversible Speculums A L EW VI cu m lu em ,T l ra po & l sa Na Fit er * Re ver s ible S pe TE M PO R Open Blades hn rs : Ke 8-08161 NAS E VI AL W W IE bl e V l& ra po em T , um ul ec Sp Na it lF sa K er sh ne r* Rev ers i TE MP OR A L Solid Blades : 48 81 8-0 EW • Unique Reversible Speculums Designed To Rest Either Nasally O r Te m p o r a l l y Simply By Flipping The Speculums Over, Allowing Eyelids To Be Opened From Narrow Palpebral Fissures To The Widest Possible Aperture. L SA NA I V • Open And Close With One-Handed Operation, Providing Unobstructed Around-The-Clock Access To The Globe During Clear Corneal And Scleral Tunnels, Trabeculectomies, PRK, ALK, LASIK, RK, AK, And Limbal Relaxing Incisions. • Special Non-Reflective Solid Blades Eliminate Glare, While Excluding The Eyelid Margins And Lashes From The Surgical Field. New Fenestrated Blades Now Available. Reusable, Autoclaveable, Made In The U.S.A., Guaranteed For Life, Available For A 30 Day Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com * Developed In Coordination With Robert M. Kershner, M.D. 1190 Rev.A Flora, Francesco Melzi (1520) ADAE 69 m ,S olid Blades 16 2: Fea st er* Sp ec ul u Speculums Feaster* Adjustable Eyelid Speculums 8 m ,O pen Wire Blade s 16 3 :F eas ter* Sp ec ul u 0 8- 0 8- • 8 Unique Locking Screw Mechanism Allows Q u i c k & E a s y Adjustment Of Blade Separation To Fit Each P a t i e n t F o r M a x i m u m E x p o s u r e & P a t i e n t C o m f o r t (Unlike Spring Action Speculum Designs). • Very Fast Placement & Setting Of The Blades. No Laborious, Tedious, Slow Screw Mechanisms To Dial To Open The Blades. • Available In Either Solid Blade Or Open Wire Tip Models. Designed To Rest Temporally For Maximum Exposure To The Globe. • Reusable, Autoclaveable, Guaranteed For Life & Available For A 30-Day Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 70 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Fred T. Feaster, M.D. 1206 Rev.A Da Vinci, Verrocchies Baptism Of Christ BAAE Speculums 60 81 :S e Stainless ulum, Spec D l* 3 ib e 05-7106: Seib el* 3D Sp ec ulu m ,T it a ni u m 80 Seibel* 3-D Lid Speculums Designed To Maximize Patient Comfort And Surgeon Ergonomics. Now Available In Both Stainless & Titanium! • Anatomically Correct Design Is Unique Among All Lid Speculums. The B l a d e s C h a n g e O r i e n t a t i o n A s They Gently Support The Lids Through An Anatomically Correct Arc Of Motion Over The Globe. This Design Contrasts With All Other Lid Speculums Which Pull Straight Apart In A Frontal Plane, Distorting The Tarsal Plate As They Open. Gentle Support Is Particularly Critical In Topical Anesthesia When Periorbital Sensation Is Intact. • U n i v e r s a l B a l l J o i n t O n A ct u a t i n g A rms A llows Screw Mechanism To Swing Out Of The Way Next To Patient’s Head During Surgery, But Also Allows Comfortable Grasp By Surgeon Away From Patient’s Head For Easy Adjustment Of The Opening. • Anatomically Formed Support Blades Are Designed To Maximize Patient Comfort. The Flattened Blades H ave I n cre a s e d S u r fa c e A re a R e la t ive To Wire Speculums Designed To Decrease Point Pressure To P a t ie n t s ’ Lid M a rg i n s , Wh i l e G i v ing Essent ia lly The Same Ergonomic Exposure As An Open Wire Design. • Design Promotes Posterior Displacement Of Eyelids To Maximize Surgical Exposure. • Reusable, Autoclaveable, Available For A Surgical Evaluation Without Obligation. Call 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Barry S. Seibel, M.D. 1196 Rev.B Giorgione, Judith AJAI 71 Section Name Speculums Brown* Triple Post Speculum D ra pe Available In Stainless & Titanium on W h o Pr c du t# 4, 16 8 0 8- s Pr od uc t # 05 , 05 1 -7 m iu ou n ta Ti tD ra pe Ins Blade ti er it les ain St ep Blade S a ra ti on it W h • Unique Blade Design Prevents Lashes From Overlapping The Drape. The Special Central Posts Prevent Lids And Lashes From Rot a t i n g In t o The Surg ica l F ie ld. • Special Fenestrated Blades Improve Exposure & Access To Superior Surgical Ap p roa ch e s B y S u p p or ting A nd Eleva ting The Middle Of The Lids. • Improves Assess & Visualization Of The Superior Cornea By Cre a t i n g An Oval Se pa ra tion Of The Lids,Preventing Drape Obstruction. • Ideal For All Anterior & Posterior Segment Surgery. • Reusable, Autoclaveable, Made In The USA,Guaranteed For Life, And Offered On A 30-Day Surgical Evaluation Without Obligation. Contact 800-637-4346 For More Information. 3360 Scherer Drive, Suite B, St. Petersburg, FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] • Website: www.RheinMedical.com *Developed In Coordination With Reay H. Brown, M.D. 72 1 Stylized Eye 4, Rhein Medical 1252 Rev.C AIAI Thank You For Your Interest In Rhein Medical Products Elevating The Quality Of Care In Ophthalmology 800-637-4346 INDEX Choppers Chang Choppers.............................. 2 Aguilar Pre-Chopper........................ 3 Quick Pick Choppers....................... 4 Diamond Knives 2.2mm Diamond Knives.................. 5 Best Diamond Knives ….................. 6 3-D Diamond Knives® For…........... 7 Rhein Advantage Knife.................... 8 New CVD Diamond Knives.............. 9 CVD Diamond Knives.................... 10 Fine Tune Your LRI Procedure....... 11 Precise LRI Diamond Knife............ 12 1.8mm Micro Diamond Knives ..... 13 Rhein 3-D Diamond Knives........... 14 3-D* Parallel & Trapezoidal........... 15 The Diamond Knife Cleaning........ 16 Dry Eye Got Dry Eye? Results!.................... 17 STOP DRY EYE FAST! A SUR…...... 18 STOP DRY EYE FAST!( MGP)…...... 19 Rhein Fire & Ice Mask................... 20 The Maskin™Probe System........... 21 Maskin™ MGD Probe System........ 22 Forceps Lens Loading Forceps.................... 23 Inamura Capsulorrhexis Cys…...... 24 Steinert DSEK Insertion Forceps... 25 Ambati DSEK Forceps................... 26 Rhein Insertion Forceps................. 27 New Micro Incision Forceps…....... 28 Rhein® Tubular Capsulorrhexis….29 Rhein Colibri Capsulorrhexis…...... 30 ICL Rowen* White-To-White Corneal….31 ICL Instruments............................. 32 Lens Cutters The Chu Foldable Lens Cutters ..... 33 Brown Silicone Lens Cutters......... 34 Capsule Polishers.......................... 36 Stewart Vibrating LASIK Spatula... 37 Johnston LASIK & LASEK….......... 38 Brown Pupil Dilator System......... 39 New 25g Vitrectomy ...................... 40 Sabet Pterygium Flap Maintainer.. 41 Pfister Suture Adjustment Set........ 42 Statim 7000................................... 43 The Sabet Lenticular Safety Net.... 44 Rousseau Chin-Lift Stabilizer........ 45 Tetz Enclavation Spreader............. 46 The Harman* Manipulator /Cap….47 Roholt Haptic Adjuster.................. 48 The Original Connor Wands.......... 49 Refractive Geggel Corneal Transplant Mark... 50 Verges Suction PRK Amoils…........ 51 IntraLASIK Instruments................. 52 Huang LASEK Instruments............ 53 Femtosecond Spatulas................... 54 Seibel IntraLase Flap Lifter &... .... 55 The New Rousseau* Slit-Lamp...... 56 Davis LRI Marker........................... 57 Ruminson LRI Marker & Seibel..... 58 Seibel Gravity Fixation Ring.......... 59 Dell LRI Markers............................ 60 Miguel Maldonado Undersurface .61 Dell Toric Axis Markers.................. 62 Dell/Donnenfeld* LRI Marker....... 63 Scissors Got Scissors................................... 64 Mansur-Aran Graft Harvesting...... 65 Single-Use Single Use Solutions...................... 66 New Rhein® Eco’s™ ..................... 67 New Blade Technology-Frown ….. 68 Speculums Kershner Reversible Speculums.... 69 Feaster Adjustable Eyelid Spec….. 70 Seibel 3-D Lid Speculums.............. 71 Brown Triple Post Speculum......... 72 Miscellaneous Henry Capsule Polisher................. 35 www.rheinmedical.com Elevating The Quality Of Care In Ophthalmology 3360 Scherer Drive, Suite B, St. Petersburg FL 33716 800-637-4346 • Tel: 727-209-2244 • Fax: 727-341-8123 Email: [email protected] * Website: www.RheinMedical.com 1148 Rev.G AGBC