LOSSNAY LGH-RX5-E
Transcription
LOSSNAY LGH-RX5-E
LOSSNAY R410A Data G6 LGH-RX5-E 1. DIMENSIONS .................................................................................................................................................... 1 - 210 2. PERFORMANCES ............................................................................................................................................ 1 - 212 3. SPECIFICATIONS............................................................................................................................................. 1 - 215 4. SAMPLE INSTALLATIONS ............................................................................................................................... 1 - 218 5. WIRING DIAGRAMS ......................................................................................................................................... 1 - 219 LOSSNAY is a perfect combination of heat recovery and ventilation, which is a leading edge product in the ventilation and air-conditioning field. The LOSSNAY core is a special preserved paper made cross-flow and plate-fin structure, which is referable below. 4˚C (39.2 0˚C (32 ˚F) Stale hot air (exhaust) SA ˚F) Fresh cool air (outdoor) EA Outdoors Stale air exhaust (dirty indoor air) Indoors Fresh air exhaust (fresh heating/cooling air) Partition plate Spacer plate 20˚C (68˚F) Stale warm air (indoor air) OA 16˚C Fresh air induction (fresh air) (60.8˚F) Fresh warm air (indoor supply air) RA Stale air induction (dirty heating/cooling air) CITY MULTI can combine LOSSNAY into the air conditioning system, performing the best solution to ventilation and air-conditioning. Outdoor unit Indoor unit Indoor unit Lossnay Remote controller Line up of LOSSNAY units LGH-15RX5 LGH-25RX5 LGH-35RX5 LGH-50RX5 LGH-65RX5 LGH-80RX5 LGH-100RX5 LGH-150RX5 LGH-200RX5 INDOOR UNITS [150m3/h Single phase 220-240V 50Hz] [250m3/h Single phase 220-240V 50Hz] [350m3/h Single phase 220-240V 50Hz] [500m3/h Single phase 220-240V 50Hz] [650m3/h Single phase 220-240V 50Hz] [800m3/h Single phase 220-240V 50Hz] [1000m3/h Single phase 220-240V 50Hz] [1500m3/h Single phase 220-240V 50Hz] [2000m3/h Single phase 220-240V 50Hz] 1 - 209 1. DIMENSIONS R410A Data G6 (Unit ; mm) LGH-15RX5-E LGH-25RX5-E Position where duct direction change is possible 95 Core, air filter, HighEfficiency filter, fan, Maintenance space 273 Maintenance cover High efficiency filter(sold separately) attachment position 103 Air filters (EU-G3) LGH-50RX5-E Air exhaust fan RA (return air) Core, air filter, HighEfficiency filter, fan, Maintenance space Maintenance cover High efficiency filter(sold separately) attachment position 64 20 124 Inspection opening 192 208 888 30 Position where duct direction change is possible Air filters(EU-G3) LGH-80RX5-E 1004 690 95 70 386 Core, air filter, HighEfficiency filter, fan, Maintenance space Maintenance cover High efficiency filter(sold separately) attachment position 908 165 Inspection opening 79 Position where duct direction change is possible Air filters(EU-G3) Position where duct direction change is possible INDOOR UNITS 389 399 Maintenance cover LOSSNAY core 79 Air supply fan Control box 1144 High efficiency filter(sold separately) attachment position 79 192 208 79 Air supply fan Control box SA (supply air) Power supply cable opening OA (outside air intake) 95 1001 954 692 20 Power supply cable opening 133 LOSSNAY core RA (return air) EA (exhaust air outlet) SA (supply air) OA (outside air intake) Inspection opening 1010 Air exhaust fan RA (return air) EA (exhaust air outlet) Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture (4-15x20 oval) 165 1036 Air exhaust fan Position where duct direction change is possible By-pass damper plate 895 Ceiling suspension fixture (4-13x20 oval) 70 More than 600 150~250 133 More than 600 150~250 Air filters(EU-G3) 242 258 LGH-65RX5-E Lossnay 30 315 Maintenance cover LOSSNAY core 79 55 Position where duct direction change is possible Core, air filter, HighEfficiency filter, fan, Maintenance space SA (supply air) Power supply cable opening 65 Air supply fan Control box High efficiency filter(sold separately) attachment position 79 142 160 888 1063 1016 745 20 80 55 315 Air supply fan Control box Inspection opening OA (outside air intake) More than 600 150~250 874 650 150~250 124 95 SA (supply air) Power supply cable opening OA (outside air intake) LOSSNAY core 64 RA (return air) EA (exhaust air outlet) 921 EA (exhaust air outlet) Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture 875 65 124 95 Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture 875 80 (4-13x20 oval) 124 Air exhaust fan More than 600 782 Position where duct direction change is possible Air filters(EU-G3) 30 273 Control box Maintenance cover High efficiency filter(sold separately) attachment position 63 780 63 LGH-35RX5-E Core, air filter, HighEfficiency filter, fan, Maintenance space Inspection opening 30 30 Position where duct direction change is possible 102 LOSSNAY core 97.5 110 780 SA (supply air) Power supply cable opening 65 Air supply fan OA (outside air intake) 30 Control box LOSSNAY core 103 SA (supply air) Power supply cable opening 65 Air supply fan 20 20 Inspection opening 735 530 782 735 530 102 150 ~250 Core, air filter, HighEfficiency filter, fan, Maintenance space More than 600 OA (outside air intake) RA (return air) EA (exhaust air outlet) 95 RA (return air) EA (exhaust air outlet) Ceiling suspension fixture (4-13x20 oval) 65 768 Air exhaust fan 142 160 Air exhaust fan By-pass damper plate 102 150 ~250 768 More than 600 102 Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture (4-13x20 oval) 65 Air filters(EU-G3) 1 - 210 1. DIMENSIONS R410A Data G6 (Unit ; mm) LGH-100RX5-E Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture (4-15x20 oval) 165 Air exhaust fan 1010 RA (return air) 1263 1231 917 EA (exhaust air outlet) More than 600 150~250 165 Air supply fan Control box Inspection opening 399 Maintenance cover LOSSNAY core 79 1144 High efficiency filter(sold separately) attachment position 79 242 258 Core, air filter, HighEfficiency filter, fan, Maintenance space 95 SA (supply air) Power supply cable opening OA (outside air intake) Air filters(EU-G3) Position where duct direction change is possible LGH-150RX5-E By-pass damper plate 1010 690 1045 27 150~250 More than 600 Inspection opening Air supply fan 110 SA (supply air) 270 OA (outside air intake) Core, air filter, HighEfficiency filter, fan, Maintenance space RA (return air) 1004 690 EA (exhaust air outlet) Ceiling suspension fixture (4-15x30 oval) 270 Air exhaust fan 399 798 Control box Power supply cable opening Maintenance cover 1144 79 242 258 700 44 242 258 High efficiency filter(sold separately) attachment position LOSSNAY core Air filters(EU-G3) LGH-200RX5-E By-pass damper plate 1010 110 270 27 150~250 More than 600 SA (supply air) Inspection opening Air supply fan 399 798 Control box Maintenance cover Power supply cable opening 79 Air filters(EU-G3) 242 258 700 1144 242 258 High efficiency filter(sold separately) attachment position LOSSNAY core 44 Lossnay OA (outside air intake) 917 1272 RA (return air) 1231 917 EA (exhaust air outlet) Core, air filter, HighEfficiency filter, fan, Maintenance space Ceiling suspension fixture (4-15x30 oval) 270 Air exhaust fan INDOOR UNITS 1 - 211 2. PERFORMANCES R410A Data G6 LGH-15RX5-E 50Hz/Single phase 220V lpy e Enth 80 alp 30 300 60 25 250 50 20 200 15 150 External static pressure mmH 2 O 70 ye nge effic ienc y(H xch a nge eati eff icie 100mm dia pipe length ng) nc y(C oo ling 20m ) Extra high 15m 10m Pa 100 High Extra low 5m 50 5 0 0 50 30 300 60 25 250 50 20 200 Extra high 15 150 100 150 Enth alpy 80 Low 10 70 Tempe efficie rature exch ncy ange exch Enth a nge alp effic ye ienc xch y (He ang atin e g) eff icie nc y(C oo ling ) ge xcha 50Hz/Single phase 240V Exchange efficiency (%) 90 Tempe efficie rature exch ncy an 200 10 20 30 20m 15m 10 10m 100 High Extra low 5m 50 5 0 250 0 50 100 (m2/h) 0 100mm dia pipe length Low Pa Enth a External static pressure mmH 2 O Exchange efficiency (%) 90 150 200 250 (m2/h) 40 50 60 70 10 0 20 30 Air volume (L/s) 40 50 60 70 Air volume (L/s) LGH-25RX5-E 50Hz/Single phase 220V Enth 80 alpy alpy ang exc ee han ge effic External static pressure mmH 2 O 50 25 250 20 200 15 150 ncy (He Pa 100 5 50 0 0 atin ienc y(Co 30m High 20m 10m 150 200 250 300 han ge 350 50 25 250 20 200 effic ie ncy (H eati effic ienc 15 150 10 100 y(Co ng) oling ) 150 dia pipe length Extra high 40m 30m Low High 400 5 50 0 0 Extra low 20m 10m 50 100 150 (m2/h) 0 e ange 60 ) 150 dia pipe length 40m 100 exch Tem efficperature ienc y exchang exc g) oling Extra low 50 alpy alpy 70 Extra high Low 10 Enth Enth fficie 60 50Hz/Single phase 240V Exchange efficiency 80 e exch Enth 70 90 Tem effic perature ienc y exchang Pa Exchange efficiency External static pressure mmH 2 O 90 200 250 300 350 400 (m2/h) 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Air volume (L/s) Air volume (L/s) LGH-35RX5-E 50Hz/Single phase 220V Exchange efficiency (%) alpy Enth alpy 70 60 exch ange exch ange 350 effic effic ienc ienc y(He y(Co oling ) 150mm dia pipe length 25 250 20 200 External static pressure mmH 2 O 15 150 10 100 Pa 50 High 20m Low Extra low 50 0 0 50 100 150 200 250 300 350 400 450 500 alpy 300 30 20 60 40 80 100 120 150mm dia pipe length Extra high 50 25 250 20 200 15 150 10 100 30m High Extra low 20m Low 10m 5 50 0 0 50 100 150 200 250 300 350 400 450 500 (m2/h) (m2/h) 0 Temp efficieerature e xcha ncy nge exch ange effic ienc exch y(He ange ating effic ) ienc y(Co oling ) Enth alpy 30m 10m 5 60 Enth 350 70 ) Extra high Exchange efficiency (%) 80 ating 300 30 50Hz/Single phase 240V 90 Temp e efficie rature ex chan ncy ge Pa 80 Enth External static pressure mmH 2 O 90 20 0 140 40 80 60 120 100 14 0 Air volume (L/s) Air volume (L/s) 50Hz/Single phase 220V 90 Exchange efficiency (%) 400 80 Tempe rature Enth excha Exchange efficiency (%) 400 80 efficie ncy efficie Enth ncy alpy (H eatin exch g) ange efficie ncy (Coo ling) Extra high alpy 50Hz/Single phase 240V 90 nge excha Tempe Enth nge 350 60 30 300 25 250 20 200 15 10 60m 50m High 150 Pa 50 200mm dia pipe length 40m Low 100 30m Extra low 5 20m 50 10m 0 0 100 200 300 400 500 600 70 35 350 60 30 300 50 25 250 20 200 15 150 700 10 alpy 20 40 60 nge efficie nc y excha alpy nge e fficien cy exch ange (Hea ting) efficie nc y (C oolin g) Extra high 200mm dia pipe length 60m 50m 40m High Low 100 30m Extra low 5 50 0 0 20m 10m 100 200 300 400 500 600 700 (m2/h) (m2/h) 0 rature excha Enth Pa 35 External static pressure mm H 2 O 70 External static pressure mmH 2 O Lossnay LGH-50RX5-E 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 160 180 200 Air volume (L/s) Air volume (L/s) INDOOR UNITS 1 - 212 2. PERFORMANCES R410A Data 50Hz/Single phase 220V 90 Exchange Tempe Entha lpy Enth 450 60 40 400 50 35 350 30 300 alpy geefficien cy exchan ency (Heatin g) cy (Coo ling) ge efficien 25 250 20 200 200mm dia pipe length 10 100 5 50 0 70 45 450 60 40 400 50 35 350 30 300 50m 40m Low High 150 15 efficiency (%) 80 ge effici exchan 30m Extra low 20m 10m 0 50Hz/Single phase 240V 90 Exchange exchan Extra high Pa External static pressure mmH2O 70 45 rature External static pressure mmH2O 80 efficiency (%) 25 250 20 200 rature exchan ge effici Entha ency lpy ex change Enth efficiency alpy exchan (Heatin ge efficien g) cy (Coo ling) 200mm dia pipe length 25 Extra low 10 5 50 20m 10m 0 100 200 300 400 500 600 700 800 900 (m2/h) 75 100 125 150 175 200 225 250 50 30m High (m2/h) 0 40m Low 100 0 60m 50m 150 15 100 200 300 400 500 600 700 800 900 Tempe Extra high Pa LGH-65RX5-E G6 0 25 75 100 125 150 175 200 225 250 50 Air volume (L/s) Air volume (L/s) LGH-80RX5-E 50Hz/Single phase 220V En tha 80 70 50 500 60 40 400 30 300 20 200 Extra high 250mm dia pipe length High 100m 80m Extra low 10 60m 100 40m 20m 0 0 200 400 600 800 1000 1200 (m2/h) 0 50 100 150 200 250 300 nge exch ange effic Enth ie ncy effic alpy exc (He ienc h atin y(C ange g) ooli ng) 70 50 500 60 40 400 50 30 300 20 200 Extra high 250mm dia pipe length High Low 90 10 80m 40m 20m 0 0 200 400 80 alpy En th alp 70 60 50 exc ge ang e 500 50 40 400 30 300 efficie ncy(H xch 800 1000 1200 50 100 150 200 250 300 350 Air volume (L/s) 90 ge han ye 600 (m2/h) 0 Tem p effic erature ienc exc y han Enth 60m 100 350 50Hz/Single phase 220V Exchange efficiency (%) 100m Extra low Air volume (L/s) LGH-100RX5-E Tem effic peratu ienc re e xch y a En tha lpy 80 exch ange effic Enth ienc effic alpy e y(H ienc xcha eati y(C nge ng) ooli ng) Low Pa External static pressure mmH 2 O 50 nge lpy 50Hz/Single phase 240V Exchange efficiency (%) 90 Tem effic peratu ienc re e xch y a Pa Exchange efficiency (%) External static pressure mmH 2 O 90 effic ie 50Hz/Single phase 240V Exchange efficiency (%) Tem p effic erature ienc Enth exc y han alpy ge exc En h a n tha ge lpy efficie exc ncy(H han eatin g) ge effic ienc y(C ooli ng) 80 eatin ncy (Co g) 70 50 500 60 40 400 30 300 20 200 olin g) 250mm dia pipe length 100m Extra high 50 250mm dia pipe length 100m Extra high 80m High Low 10 40m Extra low 100 20m 0 0 200 0 400 50 100 600 150 800 200 1000 250 1200 300 1400 350 High 10 40m Extra low 100 20m 0 0 200 0 400 50 400 100 Temp effic erature e ienc xcha y nge 70 50 500 60 40 400 30 300 20 200 70 50 500 60 40 400 30 300 20 200 50 Low High 100 0 0 500 0 100 1000 1500 2000 (m2/h) 200 300 400 1400 350 400 500 600 2500 700 Air volume (L/s) Temp effic erature e ienc xcha y nge Enth Enth External static pressure (mmH 2 O) 10 1200 300 50Hz/Single phase 240V Exchange efficiency (%) 80 Enth alpy exch Enth ang e eff alpy icie exch ncy ang (He e eff atin icie g) ncy (Co olin g) Extra high (Pa) External static pressure (mmH 2 O) 50 90 10 alpy alpy exch ang exch ang e eff icie ncy (He atin icie g) ncy (Co olin g) e eff Extra high (Pa) 80 250 Air volume (L/s) 50Hz/Single phase 220V Exchange efficiency (%) 1000 800 200 Lossnay 90 600 150 Air volume (L/s) LGH-150RX5-E 60m Low Pa 60m External static pressure m mH 2 O 200 20 Pa External static pressure mmH 2 O 80m Low 100 High 0 0 500 0 100 1000 1500 2000 (m2/h) 200 300 400 500 600 2500 700 Air volume (L/s) INDOOR UNITS 1 - 213 2. PERFORMANCES R410A Data 50Hz/Single phase 220V Exchange efficiency (%) Tem p eratu Enth 80 alpy Enth alpy 500 70 exch ange ee ffic ienc y efficie n ange efficie ncy(C ating) 10 High 100 0 1500 2000 2500 100 200 300 400 ge e ffic ienc y cy(He ange efficie ating) ooling ) 400 30 20 10 Extra high 300 High 200 Low 100 0 0 500 1000 1500 2000 2500 (m2/h) (m2/h) 0 chan efficie n ncy(C 40 Low 1000 re ex exch ange exch 50 50 500 Enth alpy 500 70 Extra high 0 eratu Enth alpy ) 300 200 Tem p 80 ooling (Pa) 20 50Hz/Single phase 240V Exchange efficiency (%) 60 40 30 90 cy(He 400 60 External static pressure (mmH 2 O) chan g exch 50 50 re ex External static pressure (mmH 2 O) 90 (Pa) LGH-200RX5-E G6 500 600 700 0 100 200 300 400 500 600 700 Air volume (L/s) Lossnay Air volume (L/s) INDOOR UNITS 1 - 214 3. SPECIFICATIONS R410A Data G6 LGH-15RX5-E LGH-15RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation By-pass ventilation Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 0.44-0.46 0.37-0.38 0.25-0.25 0.14-0.15 0.45-0.46 0.37-0.38 0.25-0.26 0.14-0.15 96-110 80-90 53-59 30-35 97-110 81-91 54-61 30-35 (m3/h) 150 150 110 70 150 150 110 70 (L/s) 42 42 31 19 42 42 31 19 (mmH2O) 10.2-10.7 6.6-7.1 3.6-4.1 1.4 10.2-10.7 6.6-7.1 3.6-4.1 1.4 (Pa) 100-105 65-70 35-40 14 100-105 65-70 35-40 14 82.0 82.0 84.0 85.5 Heating 75.0 75.0 77.5 81.0 Cooling 73.0 73.0 76.5 81.0 27.5-28 26.5-27 22-23.5 18 28.5-29 27-28 23-24 18-19 Power consumption (W) Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) 20 Under 0.8 A Less Starting current *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 6 dB greater than the indicated value. (at High Fan speed) LGH-25RX5-E LGH-25RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation By-pass ventilation Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 0.52-0.55 0.47-0.48 0.26-0.27 0.17-0.18 0.53-0.55 0.47-0.48 0.26-0.27 0.17-0.18 Power consumption (W) 113-129 102-114 56-62 36-42 115-131 103-115 56-63 36-42 (m3/h) 250 250 155 105 250 250 155 105 (L/s) 69 69 43 29 69 69 43 29 (mmH2O) 8.2-8.7 5.1-6.1 2-2.5 0.9 8.2-8.7 5.1-6.1 2-2.5 0.9 (Pa) 80-85 50-60 20-25 9 80-85 50-60 20-25 9 79.0 79.0 81.5 83.5 Heating 69.5 69.5 74.0 77.5 Cooling 68.0 68.0 72.5 76.0 26-27 25-26 20-21.5 18-19 26.5-27.5 25.5-26.5 20.5-22 18-19 Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) 20 Under 0.9 A Less Starting current *The Air outlets noise (45 angle,1.5 meters in front of the unit) is about 10 dB greater than the indicated value. (at High Fan speed) LGH-35RX5-E LGH-35RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation By-pass ventilation Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 0.92-0.92 0.74-0.74 0.5-0.51 0.28-0.3 0.93-0.94 0.77-0.77 0.51-0.52 0.28-0.3 Power consumption (W) 195-212 160-169 105-116 58-69 197-217 164-173 105-116 58-69 (m3/h) 350 350 210 115 350 350 210 115 (L/s) 97 97 58 32 97 97 58 32 (mmH2O) 15.8-16.3 7.6-8.2 2.5-3.1 0.9 15.8-16.3 7.6-8.2 2.5-3.1 0.9 (Pa) 155-160 75-80 25-30 9 155-160 75-80 25-30 9 80.0 80.0 85.0 88.0 Heating 71.5 71.5 76.5 81.5 Cooling 71.0 71.0 75.5 81.0 32-32 28.5-29.5 21.5-23 18 32.5-32.5 29.5-30.5 21.5-24 18 Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current Lossnay 29 Under 2.4 A Less *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 10 dB greater than the indicated value. (at High Fan speed) INDOOR UNITS 1 - 215 3. SPECIFICATIONS R410A Data G6 LGH-50RX5-E LGH-50RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation Ventilation mode Fan speed By-pass ventilation Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 1.2-1.25 1.0-1.0 0.85-0.85 0.4-0.4 1.25-1.25 1.0-1.0 0.85-0.85 0.4-0.4 Power consumption (W) 255-286 207-228 175-190 80-95 260-290 210-230 180-195 80-95 (m3/h) 500 500 390 180 500 500 390 180 (L/s) 139 139 108 50 139 139 108 50 (mmH2O) 15.3-15.8 6.6-9.2 4.1-6.1 1.0 15.3-15.8 6.6-9.2 4.1-6.1 1.0 (Pa) 150-155 65-90 40-60 10 150-155 65-90 40-60 10 78.0 78.0 81.0 86.0 Heating 69.0 69.0 71.0 78.0 Cooling 66.5 66.5 68.0 77.0 33-34 30.5-32 26.5-28 19 34-35 31-32.5 27-29 19 Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) 32 Under 3.0 A Less Starting current *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 dB greater than the indicated value. (at High Fan speed) LGH-65RX5-E LGH-65RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation Ventilation mode Fan speed By-pass ventilation Extra High High Low Extra Low Extra High High Low Current (A) 1.7-1.8 1.5-1.5 1.2-1.2 0.6-0.6 1.7-1.8 1.5-1.5 1.2-1.2 0.6-0.6 Power consumption (W) 350-380 308-322 248-265 120-140 350-385 310-335 250-265 120-140 (m3/h) 650 650 520 265 650 650 520 265 (L/s) 181 181 144 74 181 181 144 74 (mmH2O) 11.2-12.2 6.1-8.2 4.1-5.1 0.8 11.2-12.2 6.1-8.2 4.1-5.1 0.8 (Pa) 110-120 60-80 40-50 8 110-120 60-80 40-50 8 77.0 77.0 80.0 86.0 Heating 68.5 68.5 70.5 78.0 Cooling 66.0 66.0 68.5 77.0 34-34.5 32-33 28.5-31.5 22 34.5-35 32.5-33.5 28.5-30.5 22-22.5 Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Extra Low 40 Under 4.4 A Less Starting current *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 10 dB greater than the indicated value. (at High Fan speed) LGH-80RX5-E LGH-80RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.65 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.65 Power consumption (W) 380-415 345-370 315-340 125-145 380-415 345-370 315-340 120-145 (m3/h) 800 800 700 355 800 800 700 355 (L/s) 222 222 194 99 222 222 194 99 (mmH2O) 14.8-15.3 10.7-12.2 8.2-9.7 2 14.8-15.3 10.7-12.2 8.2-9.7 2 (Pa) 145-150 105-120 80-95 20 145-150 105-120 80-95 20 34.5-35.5 33-34 31-32 22 Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Noise (dB) 79.0 79.0 80.5 87.5 Heating 71.0 71.0 72.5 79.5 Cooling 70.0 70.0 71.5 79.5 33.5-34.5 32-33 30-31 22 (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Lossnay By-pass ventilation Ventilation mode Fan speed 53 Under 3.8 A Less Starting current *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 dB greater than the indicated value. (at High Fan speed) INDOOR UNITS 1 - 216 3. SPECIFICATIONS R410A Data G6 LGH-100RX5-E LGH-100RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation Ventilation mode Fan speed By-pass ventilation Extra High High Low Extra Low Extra High High Low Current (A) 2.3-2.4 2.1-2.1 1.7-1.7 0.9-0.9 2.3-2.4 2.1-2.1 1.7-1.7 0.9-0.9 Power consumption (W) 500-535 445-475 350-380 175-200 510-550 460-485 365-395 175-200 (m3/h) 1000 1000 755 415 1000 1000 755 415 (L/s) 278 278 210 115 278 278 210 115 (mmH2O) 16.3-17.3 10.2-11.2 5.6-6.1 1.8 16.3-17.3 10.2-11.2 5.6-6.1 1.8 (Pa) 160-170 100-110 55-60 18 160-170 100-110 55-60 18 80.0 80.0 83.0 87.0 Heating 72.5 72.5 74.0 80.0 Cooling 71.0 71.0 73.0 79.0 36-37 34-35 31-32.5 21-22 37-38 35-36 32-33 21-22 Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Extra Low 59 Under 4.6 A Less Starting current *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 17 dB greater than the indicated value. (at High Fan speed) LGH-150RX5-E LGH-150RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation Ventilation mode Fan speed Current (A) Power consumption (W) Noise (dB) Low Extra High High Low 3.5-3.5 3.2-3.2 2.9-2.9 3.5-3.5 3.2-3.2 2.9-2.9 760-830 690-740 630-680 765-835 695-745 635-685 1500 1500 1300 1500 1500 1300 (L/s) 417 417 361 417 417 361 (mmH2O) 16.3-17.8 13.3-13.8 9.7-10.2 16.3-17.8 13.3-13.8 9.7-10.2 (Pa) 160-175 130-135 95-100 160-175 130-135 95-100 80.0 80.0 81.0 Heating 72.0 72.0 72.5 Cooling 70.5 70.5 71.5 38-39 36-37.5 33.5-35 39-40.5 37.5-39 35.5-37 Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) High (m3/h) Air volume External static pressure By-pass ventilation Extra High (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) 105 Under 7.3 A Less Starting current *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 19 dB greater than the indicated value. (at High Fan speed) LGH-200RX5-E LGH-200RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation Ventilation mode Fan speed Current (A) Power consumption (W) Noise (dB) Low Extra High High Low 4.8-4.8 4.2-4.2 3.4-3.4 4.8-4.8 4.2-4.2 3.4-3.4 1035-1100 910-980 715-785 1040-1110 915-980 720-785 2000 2000 1580 2000 2000 1580 (L/s) 556 556 439 556 556 439 (mmH2O) 16.3-16.8 10.2-10.7 6.1-6.6 16.3-16.8 10.2-10.7 6.1-6.6 (Pa) 160-165 100-105 60-65 160-165 100-105 60-65 80.0 80.0 83.0 Heating 72.5 72.5 73.5 Cooling 71.0 71.0 72.0 39.5-40 37-38 32.5-34 40.5-41 38-39 33.5-35 Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) High (m3/h) Air volume External static pressure By-pass ventilation Extra High (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) 118 Lossnay Under 11.9A Less Starting current *The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 20 dB greater than the indicated value. (at High Fan speed) INDOOR UNITS 1 - 217 4. SAMPLE INSTALLATIONS R410A Data LGH-15RX5-E to 100RX5 LGH-150RX5 and 200RX5 Exhaust air grille A Exhaust grille (user supplied) Suspension bolt position Suspension bolt position Air-supply grille (user supplied) Exhaust grille (user supplied) EA (exhaust-air outlet) 150 to 250 600 or more Suspension bolt position Inspection opening LOSSNAY core/ air filter/ fan maintenance space 414 Air-supply grille (user supplied) Supply air grille OA (fresh-air intake) Duct (user supplied) Duct diameter 200 (ordered by customer) Suspension bolt position (ordered by customer) 450( 600) Inspection port Duct (user supplied) EA (Exhaust air) OA (Outside air) Inspection opening RA (Return air) Duct diameter 200 (user supplied) Heat exchanger/filter maintenance space Y piping,Dwindle pipe (user supplied) Ceiling suspension bolt position Air-supply grille (user supplied) Supply/ exhaust air grille SA (Supply air) . Always leave inspection holes ( 450 or 600) on the air filter and LOSSNAY core removal side. . Always insulate the two ducts outside the room (intake air and exhaust air ducts) to prevent condensation. .It is possible to change the direction of the outside air ducts (OA and EA side). . Do not install the vent cap or round hood where it will come into direct contact with rain water. Unit: mm Ceiling suspension bolt position B OA (Outside air) Duct diameter 250 Ceiling suspension (user supplied) bolt position A 150~250 Min. 600 B 414 EA (Exhaust air) Duct downward slope 1/30 or more (to wall side) (Rainwater entrance prevention) Deep-type hood or weather cover G6 Duct incline Over 1/30 (toward the wall) to prevent entry of rainwater EA (exhaust-air outlet) Ceiling suspension bolt (user supplied) (user supplied) OA (fresh-air intake) Exhaust grille 450( 600) Inspection port Air-supply grille SA RA SA RA (return air) (return air) (supply air) (supply air) .Always leave inspection holes ( 450 or 600) on the air filter and LOSSNAY core removal side. . Always insulate the two ducts outside the room (intake air and exhaust air ducts) to prevent condensation. .If necessar y, order a weather cover to prevent rain water from direct contact or entering the unit. Model A B LGH-15RX5 768 782 LGH-25RX5 768 782 LGH-35RX5 875 921 LGH-50RX5 875 1063 LGH-65RX5 895 1001 Model A B LGH-80RX5 1010 1036 LGH-150RX5 1010 1045 LGH-100RX5 1010 1263 LGH-200RX5 1010 1272 Lossnay Unit: mm INDOOR UNITS 1 - 218 5. WIRING DIAGRAMS R410A Data G6 LGH-15RX5 to 100RX5 GREEN/YELLOW BROWN RED TAB3 BLACK GREY YELLOW M2 TM1 L TAB5 BLUE TAB1 CN10 TAB2 N BROWN Isolator L N PE C SUPPLY FAN MOTOR POWER SUPPLY 220-240V 50Hz (*2) BLUE CN1 RED ORANGE BLUE WHITE M1 TR CN9 CN7 C EXHAUST FAN MOTOR YELLOW GM (*2) RED LS BROWN CN32 TH1(OA) ORANGE ORANGE ORANGE ORANGE CN16 SW2 SW1 CN5 SW5 CN2 BROWN CN6 ORANGE ORANGE TM4 TH2(RA) X10 9 X12 X11 TM3 6 NOTE PZ60DR-E 2 8 1 TB5 TM2 7 Operation or Delay1 monitor output MAX 240VAC 2A MIN 220VAC 100mA 24VDC 2A 5VDC 100mA 10 SA1 SA2 3 2 B (*1) 2nd remote controller (Max.2remote controllers installable cable) 2nd LOSSNAY unit (Up to max 15 units) Transmission cable (non-polar) 1S A Sheild Wire 12V or 24V DC By-pass or Delay2 M-NET monitor output 6 , 7 transmission Mr.Slim Malfunction monitor (non-polar) MELANS cable *When the optional Remote Controller PZ-60DR-E output 7 , 8 is used as the M-NET System ,connect it to 1 MAX 240VAC 1A External control input 2 of TM4 terminal block,and connect M-NET 24VDC 1A 1 3 transmission wire to A , B on TB5 terminal MIN 220VAC 100mA 5VDC 100mA block. (*1) TM4 Unchanged a-conntact Optional Remote controller 2 (PZ-60DR-E) 1 1.TM1, TM2, TM3, TM4, TB5 shown 2nd remote controller in dotted lines are field work. (Max.2 remote controllers TB5(M-NET) 2.Isolator should be provided by the customer. installable) 3.Be sure to connect the grounding wire. *Attention A M-NET transmission cable B S Sheild Wire (*1)PZ-41SLB-E and PZ-52SF-E cannot be used when using PZ-60DR-E With this product, the wiring installation method will 2nd or later main units vary according to the design of the system. Perform electrical installation to meet local electrical regulations. .Always use double insulated PVC cable for the transmission cables. .Wiring work must be performed by qualified professionals. .All supply circuits must be disconnected before obtaining access to the terminal devices. (*2) LGH-100RX5 has 2 capacitors per mortor as following drawing. M C C CN16 (Unchanged a-conntact) BROWN HI LO EXTRA-LO BY-PASS RED ORANGE YELLOW GREEN *Specifications may be subject to change without notice. Definition of Symbols Motor for exhaust fan Motor for supply fan Capacitor Motor for By-pass operation Microswitch Thermistor for outside air Thermistor for return air Switch (Main/Sub change) Switch (Function selection) Terminal block (Power supply) Terminal block (External control input) Terminal block (Monitor output) Terminal block (Transmission cable and monitor output) Terminal block (M-NET Transmission cable) Connector(Power supply) Control circuit transformer Relay contact CN1: CN2: CN5: CN6: CN7: TAB3: TAB5: CN9: CN10: CN16: CN32: SA1: SA2: SYMBOL INDOOR UNITS Connector (Transformer primary) Connector (Transformer secondary) Connector (Thermistor) Connector (Microswitch) Connector (Motor for By-pass operation) Tab connector(Fan motor) Tab connector (Fan motor) Connector (Fan motor) Connector (Fan motor) Connector (High/Low/By-pass switch) Connector (Remote control selection) Address setting rotary switch (10 digit) Address setting rotary switch (1 digit) : Indicates terminal block. : Connector. : Board insertion connector or fastening connector of control board. Lossnay M1: M 2: C: GM: LS : TH1: TH2: SW1: SW2, 5: TM1: TM2: TM3: TM4 : TB5 : TAB1,TAB2: TR1: X10,X11,X12: 1 - 219 5. WIRING DIAGRAMS R410A Data G6 LGH-150RX5 and 200RX5 POWER SUPPLY 220-240V 50Hz GREEN/YELLOW BROWN BLACK GREY YELLOW M2 SUPPLY FAN MOTOR C x103 x102 (*2) TAB1 CN10 TAB2 M1 EXHAUST FAN MOTOR BROWN BLUE TR1 CN1 x203 ORANGE BLUE x202 WHITE x203 C (*2) PE BLUE x101 x101 RED ORANGE BLUE WHITE x202 RED RED CN9 CN7 x201 WHITE RED WHITE BROWN BLACK GREY YELLOW M2 SUPPLY FAN MOTOR C (*2) RED ORANGE BLUE WHITE M1 EXHAUST FAN MOTOR C (*2) HI LO BY-PASS x201 RED ORANGE YELLOW GREEN BLACK TR2 TR3 BLACK LS GM MG BLACK BROWN CN32 TH1(OA) ORANGE ORANGE ORANGE ORANGE CN16 SW2 SW1 CN2 BROWN SW5 TM4 10 SA1 SA2 X10 9 X12 X11 2 TM2 T M3 7 8 MAX 240VAC 1A 24VDC 1A MIN 220VAC 100mA 5VDC 100mA 1 1 TB5 2 3 A 12V or 24V DC Mr.Slim (non-polar) By-pass or Delay2 monitor output 6 , 7 Malfunction monitor output 7 , 8 LS BLACK CN5 TH2(RA) 6 CN16 (Unchanged a-conntact) BROWN L N N TAB5 TAB3 BLACK x103 GREY YELLOW x102 Isolator TM1 L BROWN RED B S Sheild Wire M-NET transmission MELANS cable GM MG Operation or Delay1 monitor output MAX 240VAC 2A MIN 220VAC 100mA 24VDC 2A 5VDC 100mA (*1) PZ60DR-E 2nd remote controller (Max.2remote controllers installable cable) 2nd LOSSNAY unit (Up to max 15 units) Transmission cable (non-polar) External control input 1 3 Unchanged a-conntact NOTE 1.TM1, TM2, TM3, TM4, TB5 shown in dotted lines are field work. 2.Isolator should be provided by the customer. 3.Be sure to connect the grounding wire. *Attention *When the optional Remote Controller PZ-60DR-E is used as the M-NET System ,connect it to 1 2 of TM4 terminal block,and connect M-NET transmission wire to A , B on TB5 terminal block. (*1) TM4 Optional Remote controller 2 (PZ-60DR-E) 1 2nd remote controller (Max.2 remote controllers TB5(M-NET) installable) A B S (*2) LGH-200RX5 has 2 capacitors per mortor as following drawing. M C C M-NET With this product, the wiring installation method will transmission Sheild Wire (*1)PZ-41SLB-E and PZ-52SF-E cannot cable vary according to the design of the system. be used when using PZ-60DR-E Perform electrical installation to meet local electrical regulations. 2nd or later main units .Always use double insulated PVC cable for the transmission cables. .Wiring work must be performed by qualified professionals. .All supply circuits must be disconnected before obtaining access to the terminal devices. *Specifications may be subject to change without notice. Lossnay Definition of Symbols M1: M2: C: GM: LS: T H1: TH2: SW1: SW2, 5: TM1: TM2: TM3: TM4: Motor for exhaust fan Motor for supply fan Capacitor Motor for By-pass operation Microswitch Thermistor for outside air Thermistor for return air Switch (Main / Sub change) Switch (Function selection) Terminal block (Power supply) Terminal block(External control input) Terminal block (Monitor output) Terminal block (Transmission cable and monitor output) TB5: Terminal block (M-NET Transmission cable) TAB1,TAB2: Connector(Power supply) TR1: Control circuit transformer TR2,TR3: By-pass operation transformer X10,X11,X12: Relay contact X101,X102,X103: Relay Supply fan speed control X201,X202,X203: Relay Exhaust fan speed control CN1: Connector (Transformer primary) CN2: Connector (Transformer secondary) CN5: Connector (Thermistor) CN6: Connector(Microswitch) CN7: Connector (Motor for By-pass operation) Connector (Fan motor) CN9: TAB3: Tab connector (Fan motor) Tab connector (Fan motor) TAB5: CN9: Connector (Fan motor) CN10: Connector (Fan motor) CN16: Connector(High/Low/By-pass switch) CN32: Connector (Remote control selection) SA1: Address setting rotary switch (10 digit) Address setting rotary switch (1 digit) SA2: SYMBOL : Indicates terminal block. Board insertion connector or fastening connector of control board. INDOOR UNITS 1 - 220