Reference Guide
Transcription
Reference Guide
G U I D E Description and Operation Garment Models R E F E R E N C E The Quick Reference Guide is a guideline only and does not replace the User's Manual. Please refer to the User’s Manual for full instructions. Garment Troubleshooting Q U I C K Controller Troubleshooting COOLING THERAPY SYSTEM Step-by-Step Operation FRONT VIEW Handle Control Panel Surface Sensor Socket Core Sensor Socket Water-in Quick Coupling Connector Water-out Quick Coupling Connector Water Feeder Tube Water Level Indicator REAR VIEW Power Switch Thumb Captive Screws (4) 3-Prong Power Socket Air Outlet Grille RS-232 Connector Rear Cover 6mm Threaded Hole for Equipotentiality Screw Installation Thumb Captive Screws (2) Set: 1. Place CritiCool unit in the desired location and lock front wheels. 2. Pour cold tap water into water tank up to maximum level (between the two lines). 3. Turn power ON. • Following a short Self Test, the system automatically cools the water • Avoid further connections until patient arrival to the ICU • Place appropriate garment on bed or underneath patient (see Instructions of Use). • Connect Water tubes to garment and to CritiCool unit. The garment automatically fills up! (Lower water level in the reservoir is normal) • Check that clamps on garment are open and a clicking sound is heard. Wrap: 4. Secure on patient Cool: • Plug Gray sensor into Core socket and Green sensor into Surface socket of CritiCool unit. • Once sensors are inserted to patient and valid feedback is obtained, algorithm is activated. • The CritiCool unit will not Thermo regulate if core sensor is not properly inserted into patient • Ensure no interference from other factors influence correct continuous temperature feedback readings. • When feedback is unavailable predefined cooling program is set, an alarm sounds and a message appears. Re-warming: Gradual re-warming is advised (do not exceed more than 2 °C above actual temperature) * For Accidental hypothermia or fast re-warming: switch to Normothermia management mode CONTROL PANEL Core Temperature Surface Temperature Mode Key Cooling\Heating Status System Function Status Energy Transfer to/from Patient Set Point Temperature Alarm Mute Arrow Keys Description and Operation Step-by-Step Operation Step-by-Step Operation 6. Monitor patient temperature and system messages. Use Arrow keys to select desired mode Operation Mode Temperature Graph Stand-by Mode Treatment Mode Selection Screen Garment replacement / *Shut Down 1. 2. 3. 4. Turn OFF CritiCool unit or switch to Stand-by mode. Wait a few seconds and close clamps on garment. Disconnect Water Tubes from garment. Unwrap patient and dispose garment. • Do not use garment to lift or move the patient. • Ensure garment is fully released. * Disconnect Water Tubes and remove Core and Surface sensors from patient and from CritiCool unit. • Clean and prepare CritiCool unit and its accessories for future use. • For Disinfections / Sterilization of sensors use CIDEX / ETO only according to hospital protocol. Controller Troubleshooting An alarm will sound to inform about any problem. The system will assist you in solving the problem. Water leak between connecting tubes and CritiCool unit Water tank overfilled Possible Problem Action to be Taken Connecting tubes are not connected properly Disconnect connecting tubes from machine and connect again Damage to connecting tubes Replace connecting tubes Damage to quick coupling connector Call Biomedical department If necessary, drain water tank as follows: 1. Connect one end of the ThermoWrap connecting tube to the Water-out Quick Coupling Connector (beneath Core Sensor socket), or, Connect the gray-coded end of the CureWrap connecting tube to the Water-out Quick Coupling Connector (beneath Core Sensor socket). 2. Connect special male connector to connecting tube: For ThermoWrap, see Figure 1. For CureWrap, see Figure 2. 3. Turn CritiCool device ON. 4. Change to Operation mode. 5. Allow excess water to drain into a receptacle, pail or sink. 6. When desired water level has been reached, turn CritiCool device OFF. Special Male Connector for Draining Water Tank Figure 1 Special Male Connector for Draining Water Tank Figure 2 Controller Troubleshooting Observation Controller Troubleshooting Message HALT - PLEASE RESTART Probable Cause Action to be Taken Error during normal function Turn OFF system for three seconds and then ON again. If problem persists, turn OFF CritiCool unit and contact your local service representative. Note the number that appears on screen ATTENTION NO WATER – PLEASE ADD WATER No water in tank Refill water tank Water tank float is jammed Open water tank cap and insert long object to release float ATTENTION OUT OF NORMOTHERMIA PRESS OK TO CONFIRM Cooling Therapy Desired set-point is set to exceed 38°C (100.4oF) Normothermia Management Desired set-point is set above 38°C (100.4oF) or below current set point XX ATTENTION CHECK CORE SENSOR 11 ATTENTION CHECK SURFACE SENSOR 12 Approve action Disapprove action Misplacement of sensor in core socket Connect core sensor to appropriate socket Core adapter is connected to CritiCool unit without disposable temperature sensor Connect disposable sensor Misplacement of sensor in surface socket Connect appropriate surface sensor to socket Surface adapter is connected to CritiCool unit without disposable temperature sensor Connect disposable sensor - Indicates alarm activated Controller Troubleshooting ATTENTION CONNECT CORE SENSOR* ATTENTION WATER TEMP TOO LOW Probable Cause No Core Sensor inserted in socket Water Temperature < 10oC (50.0F) 16 ATTENTION WATER TEMP TOO HIGH Water Temperature > 42oC (107.6F) 17 ATTENTION CORE READ OUT TOO LOW 18 Patient temp ABOVE 38.5ºC (101.3ºF)** Action to be Taken Connect Core Sensor Turn OFF system for three seconds and turn ON again. If problem persists, turn OFF CritiCool unit and contact your local service representative Turn OFF system for three seconds and turn ON again. If problem persists, turn OFF CritiCool unit and contact your local service representative Cooling Therapy: Core temperature is more than 2°C below set point Normothermia management: Core temperature is less than 27.0ºC (80.6ºF) Re-warming: Do not attempt to increase more than 2 ° C above actual core temperature Insert core sensor into patient Core temperature reading above 38.5°C (101.3°F) Inform physician - Indicates alarm activated * The alarm is activated again after 30 minutes if no action is taken. ** Pressing Alarm Mute silences buzzer for this present condition and any re-occurrence of this condition for thirty minutes. ATTENTION ELECTRO-MAGNETIC INTERFERENCE 22 The CritiCool unit detects electromagnetic field higher than allowable standard The message will disappear after ten seconds If message appears for more than ten seconds, replace Core Sensor ATTENTION CONNECT SURFACE SENSOR No Surface Sensor inserted into socket Connect Surface Sensor to socket Controller Troubleshooting Message Garment Models °CureWrap Adult Model Patient Height cm (in.) 3500 Fits All Adult Sizes Pediatric ThermoWrap Pediatric Model Patient Height cm (in.) 3131 79 – 91 (31 – 36) 3136 91 – 104 (36 – 41) 3141 104 – 122 (41 – 48) 3148 122 – 135 (48 – 53) Garment Models Infant ThermoWrap Infant °CureWrap Infant Model Weight Kg (Lb) 3118 / 3518* 2.5 – 4.0 (5.5 – 8.8) 3121 / 3521* 4.0 – 7.0 (8.8 – 15.4) 3125 / 3525* 7.0 – 11.0 (15.4 – 24.2) *NEW Infant °CureWrap models Garment Models POSITIONING THE PATIENT °CureWrap Pediatric ThermoWrap Indicates Head Positioning -------- Infant ThermoWrap Indicates Armpit Line •The garment should be filled with water prior to wrapping and securing to patient. •Do not use garment to lift or move patient. •Avoid handling garment with sharp objects. •Make sure garment is not folded or clamped. •Before moving patient from the operating table, ensure garment is fully released. Garment Troubleshooting An alarm will sound to inform about any problem. The system will assist you in solving the problem. Observation Garment leak Possible Problem Accidental puncture of garment during course of operation Action to be Taken Turn OFF CritiCool unit and allow water to return to reservoir Replace garment if possible Water leak from connector between garment and connecting tube Connecting tubes are not connected properly Close garment clamps. Disconnect connecting tubes and connect again Ensure click sound is heard ATTENTION Check ThermoWrap Damage to connecting tubes Replace connecting tubes Connecting tubes are not connected Connect connecting tubes Garment is blocked due to incorrect wrapping Check for snarls, folds, or objects that obstruct water flow in garment Garment clamps are closed Check clamps 10 - Indicates alarm activated QUICK REFERENCE GUIDE Catalog No. 014-00082 Ver: 02 Copyright © 2007 MTRE Advanced Technologies 4 Ha-Yarden Street, Yavne, P.O. Box 102, Rehovot 76100, Israel TEL: 972-8-932 3333 FAX: 972-8-932 8510 Website: www.mtre.com