Integriti® Vitals automates the process of acquiring
Transcription
Integriti® Vitals automates the process of acquiring
Integriti® Vitals automates the process of acquiring, modifying and recording in near time—vital signs from the bedside directly into the EMR. Integriti® Vitals automates the documentation process reducing charting duplication and transcription errors. INT 500 WORKFLOW Software INT-Client SYNC EMR/HIS (installed on PC) Hardware Power NIBP NIBP Cuff SPO2 SpO2 Sensor Temp Probe INT-500 Nurse Patient USB COMM TEMP Power TEMPERATURE & SpO2 »Temperature SPECIFICATIONS » Dimensions INT 500 • Height 7.25” • Depth 8.25” • Width 1.60” • Weight 2.5 lbs • Power 12v DC at 420mA typical »Environmental • Operating Temperature 10 to 40° C • Operating Altitude -1,000 to 10,000 ft • Storage Temperature -20 to 50° C • Shipping Altitude -2,000 to 40,000 ft • Relative Humidity 15 to 90% BENEFITS » BENEFITS TO ORGANIZATIONS: REDUCES » BENEFITS TO USERS: PROMOTES • • • • • Ease of use • Speeds up the vitals capture process • Provides immediate access to accurate patient data • Improves the adoption of EHR and CPOE Manual transcription errors Charting omissions Delayed data entry Time for vitals capture by 1.5 to 2 hours per nurse per shift* *Stonecrest Medical Center ACCESSORIES » Standard Accessories (included): • Adult NIBP Cuff • Sp02 re-usable Finger Sensor • Oral/Axillary Temperature Probe • One (1) box of disposable temperature probe covers • USB cable » Optional Equipment & Accessories: • AC Power Adaptor • Mounting Brackets • Pediatric, Small Adult NIBP Cuff (available through OEM) • XLarge/Thigh Adult NIBP Cuff (available through OEM) • Disposable Temperature Probe Covers (available through OEM) • Temperature Calibration Plug 1152 Park Avenue Murfreesboro, TN 37129 p. (888)909-8930 f. (615)896-8906 www.enovatemedical.com [email protected] ©2014 Enovate Medical LLC. All Rights Reserved. Peripherals Not Included. All information is subject to change without notice. 051214 PS013-03 • Range (predictive) 95 to 109 °F • Range (continuous) 86 to 109 °F • Accuracy (continuous) +0.2 °F per ASTM E1112 • Resolution+0.1° C / +0.2 °F » Measurement Time • Oral • Axillary • Rectal »SpO2 • SpO2 Range • SpO2 Accuracy • Settling time • Pulse Range • Pulse Accuracy 6 - 10 seconds 8 - 12 seconds 10 - 14 seconds 1 to 100% 70 to 100% +2% full scale 1% of final reading in 15 seconds 20 to 250 bpm ± 3 bpm NIBP » NIBP - Adult Measurement Range • Systolic30 to • Diastolic • MAP • Pulse Range • Measurement Time • Cuff Pressure Range • Inflation Adjustment Range • Overpressure Limit • Single Fault Overpressure Limit » NIBP - General • Measurement Accuracy, Meets • Manometer Resolution • Cuff Pressure Accuracy 260 mmHg 20 to 235 mmHg 20 to 255 mmHg 30 to 220 bpm 38 seconds typical, 270 seconds max 0 to 270 mmHg 100 to 270 mmHg 280 mmHg 308 mmHg ANSI/AAMI Standard SP10-1992 1 mmHg ±3 mmHg or 2%, (whichever is greater) » NIBP - Pediactrics Measurement Range • Systolic 30 to 160 mmHg • Diastolic 15 to 130 mmHg • MAP 15 to 140 mmHg • Pulse Range 30 to 220 bpm • Measurement Time 20 seconds typical, 240 seconds max • Cuff Pressure Range 0 to 170 mmHg • Inflation Adjustment Range 80 to 170 mmHg • Overpressure Limit 200 mmHg • Single Fault Overpressure Limit 220 mmHg