•Material: 143 gsm Saranex 23P film laminated on spunbound

Transcription

•Material: 143 gsm Saranex 23P film laminated on spunbound
 •Material: 143 gsm Saranex 23P film laminated on
spunbound copolymer
•3 Piece Hood, 2 way zip, double zip flap & self adhesive outer flap, taped seams,
reinforced knees, elasticated ankles & cuffs.
• Hazardous chemical handling •Industrial demolition applications •Pressure spray
applications •Waste disposal •Chemical spill Handling
Technical Properties
Finished
Garment Test Data
VChem Plus
Standard
EN13034
Type6
EN13982-1
Type5
EN14605
Type3/4
EN1073-2
Class1
EN14126
Pass
EN13274
Method
3
Pass
Material Performance Test Data Class
Finished Garment Permeation Test Data
Class EN374-3 (Garment)
Chemical
Sulphuric Acid (98%)
Sodium Hydroxide (10%)
O-xylene
Butan-1-ol
Garment
6
6
6
Standard
EN530
EN863
ISO2960
ISO7854
ISO9073
EN1149-1
ISO13934
ISO5082
Chemical Permeation
VChem Plus
6
2
2
6
MD6/ CD4
Pass
MD4/ CD3
Class4
Seams
6
-
Chemical
Acetic Acid
Acetone
Acetonitrile
Acrolein
Acrylonitrile
Ammonia Gas
Aniline
Benzene
Benzyl Alcohol
Bromine
1,3-Butadiene
n-Butanol
Carbon Disulfide
Carbon Monoxide
Chlorine Gas
Chloroacetone
Cyclohexane
Cyclohexanone
1,2-Dichloroethane
Dichloromethane
Diesel Fuel
Diethylamine
Dimethylamine
Dimethyl Formamide
Epichlorohydrin
Ethyl Acetate
Ethylene Oxide Gas
Formaldehyde (37%)
Formic Acid
Gasoline
Hexamethyldisilazane
HDI - Hexamethylene
Diisocyanate
Description
Abrasion
Puncture
Burst
Flex Cracking
Trap Tear
Anti-Static
Tensile
Seam Strength
CAS Number
64-19-7
67-64-1
75-05-8
107-02-08
107-13-1
7664-41-7
62-53-3
71-43-2
100-51-6
7726-95-6
106-99-0
71-36-3
75-15-0
630-08-0
7782-50-5
78-95-5
110-82-7
108-94-1
107-06-2
75-09-2
68334-30-5
109-89-7
124-40-3
68-12-2
106-89-8
141-78-6
75-21-8
50-00-0
64-18-6
86290-81-5
999-97-3
822-06-0
VChem Plus
325
>480
390
5
45
imm.
>480
imm.
>480
imm.
>480
>480
imm.
imm.
>480
>480
79
86
>480
imm.
>480
imm.
165
>480
140
>480
>480
>480
>480
>480
>480
>480
n-Hexane
Hydrochloric Acid (36%)
Hydrochloric Acid
Hydrofluoric Acid (48%)
Hydrofluoric Acid (98%)
Hydrogen Peroxide (50%)
Jet Fuel JP-8
Methanol
Methylamine
Methyl Chloride Gas
MDA – Methylene
Dianiline
MDI - Methylene Diphenyl
Diisocyanate
Methyl Ethyl Ketone
Nitric Acid (70%)
Nitrobenzene
Nitrogen Dioxide
Oleum
Phenol (99%)
Phosphoric Acid (85%)
Phosphoric Trichloride
Sodium Hydroxide (50%)
Sodium Hypochlorite
(12%)
Styrene
Sulfuric Acid (30%)
Sulfuric Acid (98%)
Sulphur Dioxide
Sulfur Trioxide
Tetrachloroethylene
Tetrahydrofuran
Toluene
Trichloroethylene
Vinyl Acetate
Vinyl Chloride
110-54-3
7647-01-0
7647-01-0
7664-39-3
7664-39-3
7722-84-1
N/A
67-56-1
74-89-5
74-87-3
83712-44-1
>480
>480
410
>480
390
>480
>480
>480
imm.
>480
imm.
101-68-8
>480
78-93-3
7697-37-2
98-95-3
10102-44-0
8014-95-7
108-95-2
7664-38-2
7719-12-2
1310-73-2
7681-52-9
>480
>480
45
>480
>480
>480
>480
Imm.
>480
>480
100-42-5
7664-93-9
7664-93-9
7446-09-5
7446-11-9
127-18-4
109-99-9
108-88-3
79-01-6
108-05-4
75-01-4
8
>480
>480
>481
35
>480
imm.
imm.
imm.
7
>480
*It is the user’s final responsibility to select the appropriate garment and personal protective equipment for the correct level of protection that is required
for the application. The information above is based upon Technical Data that VersarPPS believes to be reliable.