Pega 357 with 04PC Control Layout Drawings
Transcription
Pega 357 with 04PC Control Layout Drawings
Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Pega 357 with 04PC Control Layout Drawings Amada America Inc. 7025 Firestone Blvd. Buena Park CA. 90621 Phone: (714) 739 2111 Fax: (714) 739 4099 Email [email protected] Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Warning ! Qualified personnel must complete all work. ! Do not apply power to the Pega 357 until an A.E.S.I. (Amada Engineering and Service Incorporated) Engineer is present and has instructed you to do so. ! Not all information required for proper installation, of the Pega 357 is included with this document. Specific details for proper installation are found in the document Pega 357 with 04PC User Pre-installation Guide available at the Amada America Internet web site at http://www.amada.com. ! Considerable effort has been made to ensure that this manual is free of inaccuracies and omissions. However, as we are constantly improving our product, some of the data contained herein may be out of date. Please check our Internet site, http://www.amada.com, for the latest release of this document. Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 2 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Table Of Contents Planning the Location of the Machine ..............................................................................................................................................4 Plan View - Pega 357.......................................................................................................................................................................5 Plan View - Pega 357 with V357hs Conveyor ..................................................................................................................................6 Plan View - Pega 357 with V357hs Conveyor and MP1225 Loader ................................................................................................7 End View - Pega 357 .......................................................................................................................................................................8 Elevation View - Pega 357 ...............................................................................................................................................................9 Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 3 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Planning the Location of the Machine The following diagrams provide the details for positioning your new machine. ! Not all information required for proper installation, of the Pega 357 is included with this document. Specific details for proper installation are found in the document Pega 357 with 04PC User Pre-installation Guide available at the Amada America Internet web site at http://www.amada.com. ! No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Pega 357. ! All of the Recommended Safety / Maintenance areas should be used, but you must at least ensure that the doors of the 04PC control unit can be opened. Any reduction of the Recommended Safety / Maintenance areas may increase the possibility of personnel injury and increase the time and cost of installation or maintenance. ! The Pega 357 and 04PC control must be protected from direct sunlight or other heat sources. Exposure to direct heating sources such as infrared heaters have been shown to affect punch and die alignment. Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 4 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Plan View - Pega 357 Electrical Requirements E1 Pega 357 230 / 460 / 3 / 60 ±10% 18 kVA 46 amps @ 230 / 3 / 60 VAC 23 amps @ 460 / 3 / 60 VAC 27.56" 80 psi @ 2.9 ft³/min. 49.21" Indicates Operator Control Station 12" E1 Adj 31.39" ust 60.21 abl e5 " 0" t o9 5.04" 0 PEGA 357 105.97" 50.00" working range Y axis origin 100.00" Maximum travel a area 50" material 71.87" 177.84" Pega 357 length 12" Scale 338.44" Recomended Safety / Maintenance Area 40" from all components 12" 0" A1 Pega 357 Fanuc 04PC Compressed Air Requirements Optional Material Support Tables Required Optional Material Support Tables Required Pega 357 Centerline A1 72.05" 76.69" 148.74" Pega 357 width 288.00" Maximum travel area 144" material 368.00" Recomended Safety / Maintenance Area 40" from all components Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 5 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Plan View - Pega 357 with V357hs Conveyor Electrical Requirements E1 Pega 357 230 / 460 / 3 / 60 ±10% 18 kVA 46 amps @ 230 / 3 / 60 VAC 23 amps @ 460 / 3 / 60 VAC 49.21" Fanuc 04PC 27.56" Compressed Air Requirements 80 psi @ 2.9 ft³/min. Indicates Operator Control Station E1 5.04" 0 31.39" 6 sta 0.21" ble 50" to 9 A1 Pega 357 Adju 12" PEGA 357 105.97" 50.00" working range Y-axis Origin 100.00" Maximum travel a area 50" material 71.87" 177.84" Pega 357 length 12" Scale 408.44" Recommended Safety / Maintenance Area 40" from all components 12" 0" E2 P357hs Conveyor 208 - 230 / 460 / 3 / 60 ±10% .8 kVA 2.1 amps @ 208 / 3/ 60 VAC 2.0 amps @ 230 / 3 / 60 VAC 1.0 amps @ 460 / 3 / 60 VAC Optional Material Support Tables Required Optional Material Support Tables Required 70.01" Pega 357 Centerline P357hs Conveyor A1 E2 44.70" Access required this area for slug removal 72.05" 76.69" 148.74" Pega 357 width 288.00" Maximum travel area 144" material 368.00" Recommended Safety / Maintenance Area 40" from all components Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 6 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Plan View - Pega 357 with V357hs Conveyor and MP1225 Loader Electrical Requirements E1 Pega 357 230 / 460 / 3 / 60 ±10% 18 kVA 46 amps @ 230 / 3 / 60 VAC 23 amps @ 460 / 3 / 60 VAC 49.21" Fanuc 04PC 27.56" Power Supply E3 MP1225 Loader 200 / 3 / 60 ±10%, 10 Kva To operate at 230 / 460 VAC a step up transformer is required with the following service is required 29 amps @ 200 / 3 / 60 VAC 26 amps @ 230 / 3 / 60 VAC 13 amps @ 460 / 3 / 60 VAC E1 6 sta 0.21" ble 50" t 31.39" 66.54" Adju 189.63" MP1225 Loader Length Scale Optional Material Support Tables Required 123.10" 12" 50.00" working range 12" A2 Y-axis load position 100.00" Maximum travel a area 50" material 12" E3 PEGA 357 105.97" 75 psi @ 31.8 ft³/min. 71.87" A2 MP1225 Loader Indicates Operator Control Station 177.84" Pega 357 length 80 psi @ 2.9 ft³/min. 408.44" Recomended Safety / Maintenance Area 40" from all components Compressed Air Requirements A1 Pega 357 MP1225 Xformer o9 5.04" 0 0" E2 P357hs Conveyor 208 - 230 / 460 / 3 / 60 ±10% .8 kVA 2.1 amps @ 208 / 3/ 60 VAC 2.0 amps @ 230 / 3 / 60 VAC 1.0 amps @ 460 / 3 / 60 VAC Optional Material Support Tables Required MP1225 Loader Access required this area for material loading / unloading 70.01" Pega 357 Centerline P357hs Conveyor A1 E2 44.70" Access required this area for slug removal 141.74" MP1225 Loader width 72.05" 76.69" 148.74" Pega 357 width 288.00" Maximum travel area 144" material 441.79" Recomended Safety / Maintenance Area 40" from all components Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 7 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. End View - Pega 357 17.32" 30.71" 119.84"* 85.59"* 37.68"* Material Pass Line 14.76" 29.53" 5 12" 12" 12" Scale 35.43" 4 76.69" 72.05" 148.74" 7 *Dimension varies with installed options Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 8 of 9 Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Elevation View - Pega 357 Center Track 200 51.77" Throat Depth 50.00" Track 200 Working Range 85.59" 62.99" 37.68"* Material Pass Line 9.84" 11.02" 6.50" 7.76" 33.47" 32.87" 33.47" 103.15" 177.84" 27.56" 12" 12" 12" Scale *Dimension subject to change with installed options Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 9 of 9
Similar documents
Panther Catalog V3 - Panther Electrical
PANTHER ELECTRICAL INDUSTRIES
#8 Kanlong St., C.P. Llenado Subdivision, Karuhatan,
Valenzuela City, Metro Manila, Philippines
Tel: (632) 293-2653; 293-2654; 292-0448
TeleFax: (632) 292-3876
E-mail:...