Pega 357 with 04PC Control Layout Drawings

Transcription

Pega 357 with 04PC Control Layout Drawings
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Pega 357 with 04PC Control Layout Drawings
Amada America Inc.
7025 Firestone Blvd.
Buena Park CA. 90621
Phone: (714) 739 2111
Fax: (714) 739 4099
Email [email protected]
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 1 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Warning
!
Qualified personnel must complete all work.
!
Do not apply power to the Pega 357 until an A.E.S.I. (Amada Engineering and
Service Incorporated) Engineer is present and has instructed you to do so.
!
Not all information required for proper installation, of the Pega 357 is included with
this document. Specific details for proper installation are found in the document
Pega 357 with 04PC User Pre-installation Guide available at the Amada America
Internet web site at http://www.amada.com.
!
Considerable effort has been made to ensure that this manual is free of
inaccuracies and omissions. However, as we are constantly improving our
product, some of the data contained herein may be out of date. Please check our
Internet site, http://www.amada.com, for the latest release of this document.
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 2 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Table Of Contents
Planning the Location of the Machine ..............................................................................................................................................4
Plan View - Pega 357.......................................................................................................................................................................5
Plan View - Pega 357 with V357hs Conveyor ..................................................................................................................................6
Plan View - Pega 357 with V357hs Conveyor and MP1225 Loader ................................................................................................7
End View - Pega 357 .......................................................................................................................................................................8
Elevation View - Pega 357 ...............................................................................................................................................................9
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 3 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Planning the Location of the Machine
The following diagrams provide the details for positioning your new machine.
!
Not all information required for proper installation, of the Pega 357 is included with this document. Specific details for
proper installation are found in the document Pega 357 with 04PC User Pre-installation Guide available at the Amada
America Internet web site at http://www.amada.com.
!
No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Pega 357.
!
All of the Recommended Safety / Maintenance areas should be used, but you must at least ensure that the doors of the
04PC control unit can be opened. Any reduction of the Recommended Safety / Maintenance areas may increase the
possibility of personnel injury and increase the time and cost of installation or maintenance.
!
The Pega 357 and 04PC control must be protected from direct sunlight or other heat sources. Exposure to direct heating
sources such as infrared heaters have been shown to affect punch and die alignment.
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 4 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Plan View - Pega 357
Electrical Requirements
E1 Pega 357
230 / 460 / 3 / 60 ±10% 18 kVA
46 amps @ 230 / 3 / 60 VAC
23 amps @ 460 / 3 / 60 VAC
27.56"
80 psi @ 2.9 ft³/min.
49.21"
Indicates Operator Control Station
12"
E1
Adj
31.39"
ust 60.21
abl
e5 "
0" t
o9
5.04"
0
PEGA 357
105.97"
50.00" working range
Y axis origin
100.00" Maximum travel
a
area 50" material
71.87"
177.84" Pega 357 length
12"
Scale
338.44" Recomended Safety / Maintenance Area 40" from all components
12"
0"
A1 Pega 357
Fanuc 04PC
Compressed Air Requirements
Optional Material
Support Tables Required
Optional Material
Support Tables Required
Pega 357
Centerline
A1
72.05"
76.69"
148.74" Pega 357 width
288.00" Maximum travel area 144" material
368.00" Recomended Safety / Maintenance Area 40" from all components
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 5 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Plan View - Pega 357 with V357hs Conveyor
Electrical Requirements
E1 Pega 357
230 / 460 / 3 / 60 ±10% 18 kVA
46 amps @ 230 / 3 / 60 VAC
23 amps @ 460 / 3 / 60 VAC
49.21"
Fanuc 04PC
27.56"
Compressed Air Requirements
80 psi @ 2.9 ft³/min.
Indicates Operator Control Station
E1
5.04"
0
31.39"
6
sta 0.21"
ble
50"
to 9
A1 Pega 357
Adju
12"
PEGA 357
105.97"
50.00" working range
Y-axis Origin
100.00" Maximum travel
a
area 50" material
71.87"
177.84" Pega 357 length
12"
Scale
408.44" Recommended Safety / Maintenance Area 40" from all components
12"
0"
E2 P357hs Conveyor
208 - 230 / 460 / 3 / 60 ±10% .8 kVA
2.1 amps @ 208 / 3/ 60 VAC
2.0 amps @ 230 / 3 / 60 VAC
1.0 amps @ 460 / 3 / 60 VAC
Optional Material
Support Tables Required
Optional Material
Support Tables Required
70.01"
Pega 357 Centerline
P357hs Conveyor
A1
E2
44.70"
Access required this
area for slug removal
72.05"
76.69"
148.74" Pega 357 width
288.00" Maximum travel area 144" material
368.00" Recommended Safety / Maintenance Area 40" from all components
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 6 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Plan View - Pega 357 with V357hs Conveyor and MP1225 Loader
Electrical Requirements
E1 Pega 357
230 / 460 / 3 / 60 ±10% 18 kVA
46 amps @ 230 / 3 / 60 VAC
23 amps @ 460 / 3 / 60 VAC
49.21"
Fanuc 04PC
27.56"
Power Supply
E3 MP1225 Loader
200 / 3 / 60 ±10%, 10 Kva
To operate at 230 / 460 VAC a step up
transformer is required with the following
service is required
29 amps @ 200 / 3 / 60 VAC
26 amps @ 230 / 3 / 60 VAC
13 amps @ 460 / 3 / 60 VAC
E1
6
sta 0.21"
ble
50"
t
31.39"
66.54"
Adju
189.63" MP1225 Loader Length
Scale
Optional Material
Support Tables Required
123.10"
12"
50.00" working range
12"
A2
Y-axis load position
100.00" Maximum travel
a
area 50" material
12"
E3
PEGA 357
105.97"
75 psi @ 31.8 ft³/min.
71.87"
A2 MP1225 Loader
Indicates Operator Control Station
177.84" Pega 357 length
80 psi @ 2.9 ft³/min.
408.44" Recomended Safety / Maintenance Area 40" from all components
Compressed Air Requirements
A1 Pega 357
MP1225
Xformer
o9
5.04"
0
0"
E2 P357hs Conveyor
208 - 230 / 460 / 3 / 60 ±10% .8 kVA
2.1 amps @ 208 / 3/ 60 VAC
2.0 amps @ 230 / 3 / 60 VAC
1.0 amps @ 460 / 3 / 60 VAC
Optional Material
Support Tables Required
MP1225 Loader
Access required this area
for material loading / unloading
70.01"
Pega 357 Centerline
P357hs Conveyor
A1
E2
44.70"
Access required this
area for slug removal
141.74" MP1225 Loader width
72.05"
76.69"
148.74" Pega 357 width
288.00" Maximum travel area 144" material
441.79" Recomended Safety / Maintenance Area 40" from all components
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 7 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
End View - Pega 357
17.32"
30.71"
119.84"*
85.59"*
37.68"*
Material
Pass Line
14.76"
29.53"
5
12" 12" 12"
Scale
35.43"
4
76.69"
72.05"
148.74"
7
*Dimension varies with installed options
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 8 of 9
Pega 357 with 04PC Control Layout Drawings
©Amada America, Inc.
Elevation View - Pega 357
Center Track 200
51.77" Throat Depth
50.00" Track 200
Working Range
85.59"
62.99"
37.68"*
Material
Pass Line
9.84"
11.02"
6.50"
7.76"
33.47"
32.87"
33.47"
103.15"
177.84"
27.56"
12"
12" 12"
Scale
*Dimension subject to change with installed options
Print Date 03/02/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 9 of 9