NIKKISO® Non-Seal ANSI Canned Motor Pump
Transcription
NIKKISO® Non-Seal ANSI Canned Motor Pump
Head-Capacity Envelope 500 NIKKISO NON-SEAL® CANNED MOTOR ANSI PUMP 400 HEAD (FEET) A60-10 HN24E 3X1-10 A05-10 HN22E 2X1-10 300 A05-10 HN22D 2X1-10 200 AA-8 HN22C 1.5X1-8 AA-6 HN21C 1.5X1-6 100 AA-6 HN21A A10-6 HN24C 3X2-6 A50-8 HN23D 3X1.5-8 AB-6 HN23C 3X1.5-6 A60-8 HN24D 3X2-8 A10-6 HN24B 3X2-6 AB-6 HN23A 3X1.5-6 0 0 50 100 200 150 250 300 350 400 FLOW (GPM) Pump Dimensions W/Water Proof Cover NOMINAL FLANGE SIZE ANSI # Conduit Tap for Thermostat/Monitor Lead Output K C Conduit Tap for Motor Lead Discharge Suction V A L AA-6 AA-6 AA-8 AA-8 A05-10 A05-10 A05-10 AB-6 AB-6 AB-6 A50-8 A50-8 A10-6 A10-6 A10-6 A10-6 A60-8 A60-8 A60-10 A60-10 Pump Model HN21A-A3 HN21C-A3 HN22C-A3 HN22C-B3 HN22D-A3 HN22D-B3 HN22E-C2 HN23A-A3 HN23C-A3 HN23C-B3 HN23D-B3 HN23D-C4 HN24B-A3 HN24B-B3 HN24C-B3 HN24C-C4 HN24D-B3 HN24D-C4 HN24E-C4 HN24E-D2 A C K L M P Q V SUCTION DISCHARGE 6.50 6.50 6.50 6.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.25 8.25 8.25 8.25 9.50 9.50 9.50 9.50 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 19.83 19.83 19.87 25.18 20.22 25.53 28.80 20.58 20.30 25.61 25.69 31.83 21.01 26.32 26.32 32.46 26.28 32.42 32.97 33.88 5.25 5.25 5.25 5.25 8.25 8.25 8.25 5.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 7.50 7.50 7.50 7.50 11.25 11.25 11.25 7.50 11.25 11.25 11.25 11.25 11.25 11.25 11.25 11.25 11.25 11.25 11.25 11.25 15.54 15.54 15.58 22.59 15.94 22.94 26.18 16.29 16.02 23.02 23.10 29.21 16.72 23.73 23.73 29.84 23.69 29.80 30.35 31.01 7.25 7.25 7.25 7.25 12.50 12.50 12.50 7.25 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 20.33 20.33 20.33 21.11 23.33 24.11 27.46 20.33 20.33 21.11 24.11 27.46 23.33 24.11 24.11 27.46 24.11 27.46 27.46 27.46 1.5 1.5 1.5 1.5 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 1 1 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 2 2 1/2” NPT Plugged Drain M8 Ground Terminal Q P M NIKKISO Pumps America, Inc. 600 Kenrick Drive, Suite Houston, TX 77060 • Phone: 281-310-6747 • www.nikkisopumpsamerica.com 3433 N Sam Houston PkwyC-1 W,•#400 • Houston, TX 77086 • Phone: 281-310-6747 • www.nikkisopumpsamerica.com © Nikkiso Pumps America, Inc., 2009 CATALOG. NO. CATALOG. NO. 2310 rev2300 1 Printed USA Oct,15, 2011 Printedininthe USA April 2009 NIKKISO Pumps America, Inc. ANSI Drop In Replacement Model HN with Electric Bearing Monitor NIKKISO NON-Seal® Canned Motor ANSI pumps are the ideal replacment canidates for existing Mechanically sealed and Magnetically driven ANSI Pumps Key Benefits Principle of E monitor When bearing wear occurs, the rotor assembly shifts along the radial and/or axial position. These minute shifts are detected by eight search coils embedded in the stator, enabling precise readings of bearing wear in both directions. Real-time bearing status is conveniently displayed on an easy-to-read LED display. Power and Direction of rotation are all indicated by LED’s. Replaces existing ANSI Pumps No piping or foundation modifications required No seals to fail or maintain - TRUE ZERO EMISSIONS True sencondary containment eliminates the possibility of product leakage No Motor/Pump/Coupling allignment No Impeller adjustments or shims Unique E-Monitor alerts you of pump and bearing status Corrosion resistant 316ss construction ANSI 150# Flanges Greater MTBR (Mean Time Between Repair) Easy to maintain Simple design equals enhanced reliability Quick Delivery from our warehouse in Houston, Tx 311 degF Temperature Limit 300 psig @ 311 DegF Pressure Limit Electronic Bearing Monitor Discharge Flange Stator Stator Liner Impeller Sleeve Shaft f Inlet Flange # Indicator Bearings " Stator Shaft ! Probe Thrust Washer Stator Band We stock pumps at our Houston, Texas office for quick delivery. Bearing Rotor Rotor Rotor Sleeve Embedded Thermostats Other Types of ANSI Pumps Bearing Building Block System Nikkiso applies the building block system to all of their canned motor pumps. Wide interchangeabilities of pump modules and motor modules are available and these modules can be freely combined, so it is possible to minimize numbers of spare pumps, motors and numbers of parts in stock. This also makes on site repair possible. Jacket or Heat exchanger Pump casing Rotor ass’y Front bearing housing Conventional Centrifugal Pumps with Double Mechanical Seals Magnetic Drive Pumps Environment pollution or fire in chemical plants is caused by liquid leakage from mechanical seals. No secondary leak containment. Large space is required for installation. Stator ass’y Flushing is required. Noise generated from coupling and motor fan. Rear bearing housing Adapter plate Base plate Increase maintenance costs for changing mechanical seals. Impeller Daily checking ------- leakage from mechanical seals and making-up lubricant. No effective way to control bearing fluid environment ------ sensitive to solids and vaporization. No way to monitor wear of impeller shaft bearings. Coupling misalignment leads to input bearing failure and rubbing of containment shell. Noise generated from coupling and motor fan. Efficiency significantly drops in high temperature application. Not suitable for high pressure design.