NIKKISO® Non-Seal ANSI Canned Motor Pump

Transcription

NIKKISO® Non-Seal ANSI Canned Motor Pump
Head-Capacity Envelope
500
NIKKISO NON-SEAL®
CANNED MOTOR ANSI PUMP
400
HEAD (FEET)
A60-10
HN24E
3X1-10
A05-10
HN22E
2X1-10
300
A05-10
HN22D
2X1-10
200
AA-8
HN22C
1.5X1-8
AA-6
HN21C
1.5X1-6
100
AA-6
HN21A
A10-6
HN24C
3X2-6
A50-8
HN23D
3X1.5-8
AB-6
HN23C
3X1.5-6
A60-8
HN24D
3X2-8
A10-6
HN24B
3X2-6
AB-6
HN23A
3X1.5-6
0
0
50
100
200
150
250
300
350
400
FLOW (GPM)
Pump Dimensions
W/Water Proof Cover
NOMINAL FLANGE SIZE
ANSI #
Conduit Tap for
Thermostat/Monitor
Lead Output
K
C
Conduit
Tap for
Motor Lead
Discharge
Suction
V
A
L
AA-6
AA-6
AA-8
AA-8
A05-10
A05-10
A05-10
AB-6
AB-6
AB-6
A50-8
A50-8
A10-6
A10-6
A10-6
A10-6
A60-8
A60-8
A60-10
A60-10
Pump
Model
HN21A-A3
HN21C-A3
HN22C-A3
HN22C-B3
HN22D-A3
HN22D-B3
HN22E-C2
HN23A-A3
HN23C-A3
HN23C-B3
HN23D-B3
HN23D-C4
HN24B-A3
HN24B-B3
HN24C-B3
HN24C-C4
HN24D-B3
HN24D-C4
HN24E-C4
HN24E-D2
A
C
K
L
M
P
Q
V
SUCTION
DISCHARGE
6.50
6.50
6.50
6.50
8.50
8.50
8.50
8.50
8.50
8.50
8.50
8.50
8.25
8.25
8.25
8.25
9.50
9.50
9.50
9.50
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
19.83
19.83
19.87
25.18
20.22
25.53
28.80
20.58
20.30
25.61
25.69
31.83
21.01
26.32
26.32
32.46
26.28
32.42
32.97
33.88
5.25
5.25
5.25
5.25
8.25
8.25
8.25
5.25
8.25
8.25
8.25
8.25
8.25
8.25
8.25
8.25
8.25
8.25
8.25
8.25
7.50
7.50
7.50
7.50
11.25
11.25
11.25
7.50
11.25
11.25
11.25
11.25
11.25
11.25
11.25
11.25
11.25
11.25
11.25
11.25
15.54
15.54
15.58
22.59
15.94
22.94
26.18
16.29
16.02
23.02
23.10
29.21
16.72
23.73
23.73
29.84
23.69
29.80
30.35
31.01
7.25
7.25
7.25
7.25
12.50
12.50
12.50
7.25
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
20.33
20.33
20.33
21.11
23.33
24.11
27.46
20.33
20.33
21.11
24.11
27.46
23.33
24.11
24.11
27.46
24.11
27.46
27.46
27.46
1.5
1.5
1.5
1.5
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
2
2
2
2
2
2
2
2
1/2” NPT
Plugged
Drain
M8
Ground Terminal
Q
P
M
NIKKISO Pumps America, Inc.
600 Kenrick
Drive, Suite
Houston,
TX 77060
• Phone:
281-310-6747
• www.nikkisopumpsamerica.com
3433
N Sam Houston
PkwyC-1
W,•#400
• Houston,
TX 77086
• Phone:
281-310-6747
• www.nikkisopumpsamerica.com
© Nikkiso Pumps America, Inc., 2009
CATALOG.
NO.
CATALOG.
NO. 2310
rev2300
1
Printed
USA
Oct,15,
2011
Printedininthe
USA
April
2009
NIKKISO Pumps America, Inc.
ANSI Drop In Replacement
Model HN with Electric
Bearing Monitor
NIKKISO NON-Seal® Canned Motor ANSI pumps are the ideal replacment canidates for existing Mechanically sealed and
Magnetically driven ANSI Pumps
Key Benefits
Principle of E monitor
When bearing wear occurs, the rotor assembly
shifts along the radial and/or axial position. These
minute shifts are detected by eight search coils
embedded in the stator, enabling precise readings
of bearing wear in both directions. Real-time bearing
status is conveniently displayed on an easy-to-read
LED display. Power and Direction of rotation are all
indicated by LED’s.
Replaces existing ANSI Pumps
No piping or foundation modifications required
No seals to fail or maintain - TRUE ZERO EMISSIONS
True sencondary containment eliminates the possibility
of product leakage
No Motor/Pump/Coupling allignment
No Impeller adjustments or shims
Unique E-Monitor alerts you of pump and bearing status
Corrosion resistant 316ss construction
ANSI 150# Flanges
Greater MTBR (Mean Time Between Repair)
Easy to maintain
Simple design equals enhanced reliability
Quick Delivery from our warehouse in
Houston, Tx
311 degF Temperature Limit
300 psig @ 311 DegF Pressure Limit
Electronic
Bearing
Monitor
Discharge
Flange
Stator
Stator
Liner
Impeller
Sleeve
Shaft
f
Inlet
Flange
#
Indicator
Bearings
"
Stator
Shaft
!
Probe
Thrust
Washer
Stator Band
We stock pumps at our Houston, Texas office
for quick delivery.
Bearing
Rotor
Rotor
Rotor
Sleeve
Embedded
Thermostats
Other Types of ANSI Pumps
Bearing
Building Block System
Nikkiso applies the building block system to all of their canned motor pumps. Wide interchangeabilities of pump modules
and motor modules are available and these modules can be freely combined, so it is possible to minimize numbers of
spare pumps, motors and numbers of parts in stock. This also makes on site repair possible.
Jacket or Heat
exchanger
Pump casing
Rotor ass’y
Front bearing housing
Conventional Centrifugal Pumps with Double Mechanical Seals
Magnetic Drive Pumps
Environment pollution or fire in chemical plants is caused
by liquid leakage from mechanical seals.
No secondary leak containment.
Large space is required for installation.
Stator ass’y
Flushing is required.
Noise generated from coupling and motor fan.
Rear bearing housing
Adapter plate
Base plate
Increase maintenance costs for changing mechanical seals.
Impeller
Daily checking ------- leakage from mechanical seals and
making-up lubricant.
No effective way to control bearing fluid environment
------ sensitive to solids and vaporization.
No way to monitor wear of impeller shaft bearings.
Coupling misalignment leads to input bearing failure
and rubbing of containment shell.
Noise generated from coupling and motor fan.
Efficiency significantly drops in high temperature application.
Not suitable for high pressure design.

Similar documents