iXP - Ana Digi Systems
Transcription
iXP - Ana Digi Systems
Human Machine Interface XGT Panel iXP Series / XP Series Leading Innovation, Creating Tomorrow XGT Panel (iXP series/XP series) 02_03 LSIS creates the core automation solutions for the fields ranging from production facilities to information systems. It is the device and software operable using a designed screen for users to monitor and control the operating status of given facilities and equipments. Windows CE platform based XGT panel is a user-friendly solution, providing convenient, clear and realistic display, prompt data transmission and processing as well as easy environments. Based on the advanced technologies, LSIS satisfies various requirements of clients, from unit facilities to advanced industrial fields, leading the HMI market. C O N T E N T S XGT Panel XGT Panel iXP Series Products Line Up Feature 04 06 08 Hardware Related Functions XP-Builder Software Related Functions Advanced Functions Link with Controllers External Monitoring Function System Block Diagram 10 14 16 18 20 22 24 Our Solution Products 26 iXP Series XP Series XP40 28 30 32 List of Communication Drivers 34 XGT Panel neXXt Generation Technology We are in the forefront with advanced technologies for clients. XGT Panel (iXP series/XP series) XGT Panel is a brand new HMI product with an intensive and advanced technology of LSIS to cope with the rapidly changing market. It is an innovative product having both reliability and convenience based on Window CE Platform. With the user-oriented convenience, it offers high-resolution, realistic display, prompt data transmission and processing and user-friendly interface. LSIS, offering a Leading Solution in the automation field, proudly presents the XGT Panel series at the HMI market with the advanced technologies and product quality, following the XGT PLC. Excellent Performance & Convenient Functions Clear and high-resolution display with 16.7M TFT and 65K TFT colors Various vector symbols and high quality raster symbols Supports a wide range of graphic formats including BMP, JPG, GIF, WMF Simple video clips with GIF drawing 10/100 BASE-T Ethernet interface as a default Convenient and easy screen editing Enhanced data management function (Logging, Recipe and Alarm) Read function of the controller’s status information (Diagnosis, Monitoring and Maintenance) Multi-lingual display of up to 8 languages and a batch language changing function Offline simulation program (Link with the XG5000 simulator) HMI S/W tag function (Easy to change the device address mapped to graphic objects) USB Host/Device function for using various PC devices (Mouse, keyboard, and etc) Sufficient memory space for Project Excellent performance and convenient functions 04_05 XGT Panel iXP Series Convenient control with a single touch! A user-oriented interface, enhanced performance, and soft and quick screen switching and respond speed to touch! Meet iXP series of LSIS that genuinely and fully connects humans with equipments. XGT Panel (iXP series/XP series) 06_07 It is highly competitive using the user-friendly technologies. Quick screen switching and response speed to touch 16.7M TFT colored LCD Large drawing / backup memory (Drawing-128MB, Backup-1MB) Sound I/O support Various Interfaces USB Host 3ch (Front: 1, Rear: 2), Device 1ch (Front) CF card and SD card Various communication drivers provided Presence sensor applied (within 1m) High Speed Presence Sensor High-performance 1GHz CPU is installed to improve the data and screen switching speed, and Windows CE 6.0 Professional OS is adopted to execute Net-based external applications. Sensor detects movement within 1m, to control the backlight, ensuring a longer life of the product. More Colorful Large Memory High luminance/resolution LCD with an LED backlight and 24 bit colors to express clear and vivid colors of 16,777,216. Large device memory is provided to save mass data. Storage space for screen and images Data backup space for alarm and logging 128MB 1MB 512KB 10MB XP iXP XP iXP Products Line-up Window CE-based new HMI developed with advanced technologies of LSIS to optimize the user experience XGT Panel iXP/XP Series iXP Series 15”(38cm) iXP90-TTA 12.1”(31cm) iXP80-TTA Standard Ethernet I/F Serial I/F(RS-232C) Serial I/F(RS422/485) USB I/F CF Card I/F, SD TFT 16,777,216 colors XGA(1024×768 dots) 15”(38cm) XP90-TTA TFT 16,777,216 colors SVGA(800×600 dots) 12.1”(31cm) 10.4”(26cm) iXP70-TTA TFT 16,777,216 colors SVGA(800×600 dots) 10.4”(26cm) XP80-TTA XP70-TTA TFT 65,536 colors SVGA(800×600 dots) TFT 65,536 colors VGA(640×480 dots) XP Series General Ethernet I/F Serial I/F(RS-232C) Serial I/F(RS422/485) USB I/F CF Card I/F, SD Expansion port Economical Serial I/F(RS-232C) Serial I/F(RS422/485) USB I/F CF Card I/F TFT 65,536 colors XGA(1024×768 dots) XGT Panel (iXP series/XP series) 08_09 8.4”(21cm) iXP50-TTA TFT 16,777,216 colors SVGA(800×600 dots) ※ Coming soon 8.4”(21cm) XP50-TTA TFT 65,536 colors VGA(640×480 dots) 7”(17.7cm) 5.7”(14cm) XP40-TTA XP30-TTA XP30-BTA TFT 65,536 colors WVGA(800×480 dots) TFT 65,536 colors QVGA(320×240 dots) STN MONO (8-column Gray) QVGA(320×240 dots) XP30-TTE XP30-BTE TFT 256 colors QVGA(320×240 dots) STN MONO Economical type (8-column Gray) QVGA(320×240 dots) ※ CF card I/F and expansion ports not supported. XP40-TTE TFT 65,536/256(Default) colors WVGA(800×480 dots) ※ CF Card I/F not supported. ※ CF Card I/F and USB I/F not supported. Feature Hardware Related Functions iXP Presence Sensor (Detects the body movement within 1m) VM Module Connector Option Card Connector SD Card CF Card USB Host 1ch USB(HOST) 10BASE-T/100BASE-TX (Connected to a USB memory, mouse and keyboard) USB 2.0 Device AUDIO OUT RS-422/485 RS-232C (Upload/Download of drawing) iXP 1 Respective Front USB Host/Device Channel An additional USB host channel is installed in the front panel. A front USB host is used to connect to a USB memory, mouse and keyboard. A front USB device port is used to change the XP-Runtime without opening a control panel or download/upload the drawing file created using XP-Builder. USB download cable (USB-310A) Front USB Port USB-310A iXP Sound Output Function (For all iXP models) The sound files (wav, mp3) registered using XP-Builder can be output to speakers connected to HMI. An alarm is generated via speakers to warn operators. Up to 512 sound files can be saved. An error Occurred An alarm is turned on Sound Files: Max 512 files PLC iXP Speaker iXP Function to use SD Cards iXP supports additional SD memory cards along with previous USB/CF memory cards to diversify the backup means. Additional XGT Panel (iXP series/XP series) 10_11 iXP Presence Sensor (For all iXP models) The XP presence sensor detects movement within 1m to turn on a backlight. When not used, it turns OFF the screen to maintain a longer lifespan of the backlight. 1m Detection of movement Detection of lateral movement Up/Down 50 degrees, Left/Right 70 degrees (Infrared ray 5 ~ 20 microns detected) Feature Hardware Related Functions XP RS-422/485 CF Card USB Host Support Effective use of USB memory RS-232C XP USB Host Support Ethernet XP Effective Use of USB Memory 2 USB interface channels Various access devices can be used using the USB I/F. Access to mouse, keyboard, a USB external hard disk, barcode reader and USB hub is possible, and continuous upgrades are under progress as well as developments to cope with drivers are continued. PLC data can be saved in a CF card or USB memory. If necessary, they are converted into a CSV format to be used to prepare daily and monthly reports. When the drawing files using XP-Builder are saved in a CF card or a USB memory and copied to the XGT Panel, they can be executed without being sent via cables. When there are several XGT Panels, one CF card or USB memory can be used to copy each XGT panel, allowing a setup. A CF card or a USB memory can be used for engine updates and upload/download of drawing files. Project File (Memory Stick) Barcode Reader XP A type USB Hub Keyboard/Mouse USB Cable (XPO-USBC) USB cable is used for screen data transmission and XP-Runtime updates. The versions before XP-Builder 1.30 are not installed with the USB driver, thus it must be installed. USB External Hard Disk XGT Panel (iXP series/XP series) Hardware Related Functions iXP iXP 12_13 XP XP Ethernet method for Quick Transmission of Mass Data Ethernet method has improved the transmission speed. Compared to the conventional RS-232C method, a quicker transmission speed: 115kbps �10/100Mbps Regardless of the memory capacity, the drawing files can be quickly uploaded/ downloaded, and logging/alarm/recipe data can be conveniently used. Ethernet method is used for various production data collection, monitoring and control using PC. iXP XP Barcode Scanner Communication ASCII data imported by accessing a barcode scanner from XGT Panel can be saved in the user-assigned PLC or XGT Panel’s internal memory. Complete Bit that allows users to check whether the XGT Panel has read the data without errors can be randomly saved. Communication with barcodes is possible by using the RS-232C interface installed in the XGT Panel. iXP Barcode Reader PLC RS-232C XP Providing Various Communication Channels Using RS-232C, RS-442/485 and Ethernet, XP and iXP are capable of communicating with up to 4 and 6 types of controllers, respectively. Refer to the system block diagram Page 31. (XP30 economical type does not have an Ethernet module.) Feature XP-Builder XGT Panel offers easy and user-friendly multi-interface. XP-Builder Functions Implementation of multiple programs In order to use the previously created drawing data for a new drawing, more than 2 XP-Builder programs are executed simultaneously. Function to check data Cross-reference function of devices •To check for any error on the data created, and errors can be corrected by clicking on them. •The specific description of error created is displayed. Devices used for drawing data and tags are displayed. Drawing Editor: XP-Builder Project Window Aligned for easier addition and edition of project view screens and special functions. Data Element Window Property Window •Displays the objects on a screen currently shown. •When double-clicked, a window on setting the properties appears. Project Window Screen Edit Output Window •Displays the error checked on drawing data and the search results. •It displays the specific description of the errors created. Tool Box Used to select an object or draw a shape. Data Elements Library Window •Library is divided by category for easier use, and preview is used for drawing. •Convenient for users to register and delete the Library. •Drag & Drop is used for a screen insertion. Output XGT Panel (iXP series/XP series) 14_15 Various fonts with free setting options Tag function •Users can set device address by desired name, which can be used in an object. •When a set device is tagged to an object, addresses can be changed, collectively •Windows fonts used in a PC can be transmitted to HMI for use. •When using Windows fonts, font attributes (Italic, bold and underline) can be used as well. •Various font sizes including True Type are supported. •Supports the Unicode, characters of other countries such as the standard font and high-quality fonts are beautifully displayed. •Sophisticated and elegant text can be used to create a screen using various fonts. •Up to 10,000 tags can be registered. Animation function •When GIF format is used, animation effects can be realized depending on the state of given bit. •When a video clip on given site is created into GIF to be added to a drawing screen, more accurate information can be delivered to users. (Video clip files can be created using the commercial software for GIF creation) Video Clip GIF User-oriented screen UI Providing a flexible script language Tool Box Library Window •Provides a screen UI that can be easily used considering user’s experiences. •Divided into categories so that a graphic library can be easily searched. •Various graphic libraries are offered for enhanced usability. Property Window Function used to change the properties of several objects, so that users do not have to open each object like a button or a lamp for modification. •A lot of objects on screen can be all selected to replace the pictures, making users more convenient. •When modifying several objects, only the objects with the same function should be selected. •The picture and the properties can both be changed. Feature Software Related Functions Multi-lingual support & conversion to respond to the global enterprise environments In response to enterprise environment of global era, up to 8 languages can be simultaneously converted and users can select a language depending on his/her nationality. When desired character string is registered in a table, a language can be converted into a device value and switched upon operation. The languages supported include Korean, English, Chinese (PRC/Taiwan), Japanese, French, Turkish, Iranian (Persian), German, Greek, Russian, Italian, Norwegian, Polish, Portuguese and Spanish, all of which are supported in Windows. Strict control management using security setting Upon PLC control using objects like a switch or an input method editor, only the authorized users can perform controls depending on the set security level. It supports 10 security levels in total, and the password of a sub-level can be accessed using the password of a main level. When the security level is authorized, a session is disconnected after a certain period of time, asking for the password again. Free and easy moving of parts The fixed values and the parts related to the word device are selected/ switched to be displayed on a screen, and the images registered as the given parts can be used. A mouse is used to set the movement points for free moves, linear moves, and device moves based on the X and Y coordinates, which can be chosen by users. Free moves 3 2 4 1 5 Linear moves 1 2 3 4 5 XGT Panel (iXP series/XP series) 16_17 Automatic registration of a character string table Memo pad function Function to automatically register the character strings directly input on shapes or objects to a character string table. Function to create or save a short message by selecting various pen thicknesses and colors on XGT Panel. When the file created using a single language is to be changed to a character string table for the purpose of multi-lingual support, it can be automatically registered to the character string table without inconvenience of users. All the static strings used in objects can be registered in the character string table. Up to 10,000 character strings can be added to a character string table, and the name of a new character string table and the editing languages can be set and registered by users. Select “Automatic registration of strings to the table” from the [Tool] menu Input of Korean language (For only iXP models) A Korean input keypad is provided so that the character strings or messages in Korean can be used. Korean is available for objects. It is useful in exchanging messages between operators working in turns. The user chooses the thickness and color of the pen and writes on a screen in order to input the message. Such memo can be saved in a CF card or a USB memory, and the data are archived even when the power is turned off. Users touch the screen and drag to create a memo. When creating a memo, users can UNDO/REDO the memo, the thickness/color of a pen can be changed, and a specific memo or all memos can be deleted. Feature Advanced Functions Alarm Function Logging Function History Alarm The history of alarms can be saved in the device to check the description of occurrence. The alarm can be categorized into up to 8 upper and 8 lower class groups or an alarm list, and an alarm explorer can display only the group alarms the user may desire. When a screen on description to check the details of alarms generated is registered, the detailed screen window linked to the alarm will appear. (It can be used to check the measures or detailed description when an alarm is generated.) Flow Alarm The alarm generated is displayed on the upper/mid/lower section for users to promptly take actions. Flow alarm can be set to be operable at a specific screen, so it can be used to deliver the information on equipments and company. System Alarm When a serious fault or a trouble of HMI occurs, the system alarm informs the users, which is a critical function. It offers a cyclic logging that is repeated depending on the time and device state and a conditional logging which works under the device conditions. Up to 32 logging areas (conditions) can be provided, and the maximum size of an area can be set up to 256Kbyte. Up to 100 words (64Bit upon bit logging) per logging can be saved. Basically, logging is saved in the built-in SRAM(256Kbyte), and the backup of logging is available using the CF card, USB memory stick or USB external hard disk. Logging data can be viewed in XGT Panel using a logging view object, and they can be converted into a CSV format to be easily edited using a PC via software such as EXCEL. History Alarm System Alarm Alarm Explorer Flow Alarm PC reads the CF card data. Detail Screen Window PLC Encryption of Logging/Alarm Backup Files E-mail Function It offers a function to send backup files (.csv) using the E-mail address registered upon backup of the logging and alarm data in XGT Panel. The E-mail function for logging can only send the backup files of the group desired for each logging group. The E-mail function for history alarm includes a function to send to the E-mail only on the alarm messages to the designated receivers when the user-assigned alarm is generated or recovered. The logging and alarm backup files sent can be easily analyzed in PC using a program like EXCEL. An alarm has occurred!! The backup file format can be archived as binary files to prevent the data from being damaged or manipulated. The encrypted files can be converted into CSV files using a CSV file converter offered from XP-Builder. XGT Panel (iXP series/XP series) 18_19 Script Scheduler Scheduler assigns an operation to be executed on a set time. Available functions include Bit ON/OFF, setting Word values and a script operation. Each scheduler can assign up to 8 operations. Up to 32 schedulers can be set. Write Providing a flexible script language It is difficult to perform drawing using only the provided object functions, and it can be supplemented using a script. A structured language similar to the C language is used for user’s convenience. The script using complicated arithmetic operations and various functions is executed to greatly reduce the load upon external controllers. A validity check of the grammar on the created scripts is available. Various uses of scripts A wide range of scripts including global scripts, screen scripts and object scripts can be used depending on the usage. A global script operates according to ON/OFF of the device assigned, regardless of the screen operation, and a special device can be used for scripts in a regular basis. An object script can perform operational management of the object devices. A script can run when a screen opens or closes. Convenient script tool box & script error check Recipe After the data to be written on PLC are created, the data values created on a PLC device continuously connected to a specific device can be written. It can read a lot of device values from the PLC continuously connected to a specific device. XP-Builder can register up to 32 recipe items. Each recipe can register up to 10000 Word/D Word devices and 255 table blocks. Recipe data are saved in a non-volatile memory of XGT Panel. Thus, when the power is out, the data saved at the last minute are kept. Recipe data can be registered and edited using a XGT Panel or an EXCEL program. Data can be written with PLC on the internal memory of XGT Panel, and they can be imported from PLC to XGT Panel. PLC Can be edited in EXCEL Data can be written and read in a non-volatile memory. Simple & Easy Editing Feature Link with Controllers Convenient Simulator Link with the PLC Simulator Offline simulation Without XGT Panel, the drawing data can be directly viewed from PC. Devices can be monitored using a PC, and values can be directly input to check operations. A simulator is used to check the operations just like the XGT Panel. Before transmitting the drawing data to HMI, data errors and abnormal operations can be checked. When XG5000 simulator runs in a PC, it links to this simulator to directly control and monitor the PLC. Operational data values of XG5000 simulator are reflected in the XP-Builder simulator, and when the values are input at XP-Builder, they are reflected as the operational data values in XG5000 simulator. Simulator Simulator Virtual Device Input XG5000 Simulator Path-through Using XGT PLC for batch-registration of devices When XGT Panel is connected to PLC with CPU serial port, PLC ladder program can be modified using the internal Ethernet. It is available only when the communication between the XGT Panel and the PLC is a CPU serial connection (Cnet module is also possible for the LSIS PLC). Users no longer have to change the cable for PLC program modification, or to go to the PLC for changes. A program can be modified even when a control panel is far away. Ethernet Serial (CPU) Note) Used when the communication between the XGT Panel and the PLC is the CPU serial communication (tag function) The variable names used in the PLC program that is created using XG5000 are automatically registered in XP-Builder, so that they can be used in drawings. [Save as a Variable/Description File] of XG5000 is used to first save the variable names used as CSV files. Using [Import XG5000 Symbols] from the [Tag] item of XP-Builder, an automatic registration via tags is possible (Array variables supported). Without changing the memory address, the variables used in the PLC program can be used. XGT Panel (iXP series/XP series) 20_21 Communication Options RAPIEnet(XPO-EIMT) optic ring system diagram Fieldbus option provided Various Fieldbus communications using the XGT Panel options (RAPIEnet, Profibus-DP and CANopen Slave offered) Note) An option module supports only XP (iXP to be supported in the future) XP-Server Function The data required from the production site’s XGT Panel can be directly collected or saved in a PC. It has several roles including a mutual data exchange between several XGT Panels, or sending an E-mail or connecting to a Database. It connects to the Database via PC to save, inquire and manage the XGT Panel data. When a trigger condition is generated, users will be informed via data E-mail of PC. When a trigger condition is generated, it imports or writes the screen capture, logging, alarm and recipe data of a specific XGT Panel. It is possible to collect various information including production outputs and causes of errors and failures from the XGT Panel to the DB server Database Factory Data Ethernet Data Data Data Data Feature External Monitoring Function ※ Only the Ethernet-support models can use the function. XP-Remote An XGT Panel screen can be monitored and controlled remotely with a PC. Up to 4 PCs can remote-access to a single XGT Panel. (Only one PC can access XP-VNC.) Remote PC control of XGT Panels can be authorized or restricted (When not authorized, it is impossible to control with the Remote PC). There is a synchronization mode and a non-synchronization mode, which allows users to monitor the XGT Panel and the Remote PC screen under the same or different conditions. XP 1 XP 2 XP 1 XP 2 XP 1 XP 2 HUB XP 1 XP 2 Factory Ethernet XP n XP 1 XP 2 XGT Panel (iXP series/XP series) Web Server The screen currently viewed on a XGT Panel can be viewed on a web browser via Internet. It is accessible in any place where Internet is connected. It can be connected to multiple Internet Explorers. (Impossible to access the XP screen at the same time) It is possible to upload the logging and alarm backup files as csv files in the XGT Panel. It is possible to restrict access of specific users or groups. Internet ※ The functions described above are available when a Web Server Program is installed to the XGT Panel using XP-Manager. XP-VNC The screen currently shown in the XGT Panel can be viewed from the user’s PC. Several XGT Panels can be monitored and controlled with one PC. After inserting the IP of XGT Panel to be accessed from XP-VNC (S/W for PC), the current screen of the XGT Panel can be monitored and controlled. It is possible to restrict PC control when the XGT Panel is under operation on site (VNC interlock device provided). XP 1 XP 2 HUB XP 1 XP 2 XP n 22_23 Feature System Block Diagram 1 : 1 Serial/Ethernet Communication One controller to one XGT Panel ※ In case of the 1:1 Ethernet communication, a cross cable should be used. RS-232C RS-422/485 Ethernet N : 1 Serial Communication One controller to multiple XGT Panels (serial) ※ Up to 16 XGT Panels can be connected, but the speed for screen refreshing varies according to the number of panels. ※ Connection available only to specific controllers (limited to PLCs) Only RS-485 available Simultaneous connection with multiple controllers 4 kinds of controllers to one XGT Panel Ethernet ※ Without the RS-422/485 and RS-232C, up to 4 controllers can be connected using only Ethernet. ※ When it comes to iXP, up to 16 controllers can be connected. XGK RS-232C Master K RS-422/485 GLOFA XGI XGT Panel (iXP series/XP series) 1 : N Serial Communication (Multi Drop) Multiple controllers to one XGT Panel ※ When 1:N communication is applied, the same types of controllers should be used. RS-422/485, 500m Max N:1 Ethernet Communication One controller to multiple XGT Panels (Ethernet) ※ According to the controller type, the number of XGT Panels connected may vary. Ethernet N:M Ethernet Communication Multiple controllers to multiple XGT Panels Ethernet 24_25 XGT Panel (iXP series/XP series) 26_27 Our Solution We are leaping as a global leader beyond the top enterprise in Korea in the field of automation solutions. The LSIS HMI solutions incorporate the core H/W and S/W technologies and services, which are optimized for client’s environments at various industrial sites, ranging from unit machines to massive process control. Products iXP Series High-resolution and performance 1GHz high-performing CPU & quick screen refreshing speed 16,777,216. TFT color (24bit) support & high-luminance/resolution LCD Mass internal memory (User memory: 128MB, Data backup: 1MB) User-oriented simple environment Various storage interfaces (USB/CF/SD) Movement detection (presence sensor) system (within 1m) Dimensions [Unit: mm] iXP90 ! iXP70 ! ! iXP80 ! XGT Panel (iXP series/XP series) General Information Item Ambient Temperature Storage Temperature Ambient Humidity Storage Humidity Vibration resistance Shock resistance Vibration resistance Description 0℃~+50℃ -20℃~+60℃ 10~85%RH, without dew condensation 10~85%RH, without dew condensation Occasional vibration Counts Frequency Amplitude Acceleration 5 ≤ f < 9㎐ 3.5mm 9 ≤ f ≤ 150㎐ 9.8㎨ 10 times each direction Continuous vibration (X, Y and Z) Amplitude Frequency Acceleration 1.75mm 5 ≤ f < 9㎐ 9 ≤ f ≤ 150㎐ 4.9㎨ Maximum shock acceleration: 147㎨(15g) * Authorization time: 11ms * Pulse waveform: Half-sine wave (3 times each of X, Y and Z) * Square wave impulse noise Electrostatic discharge Radiated electromagnetic field noise Fast transient/Burst noise Operating ambience Altitude Pollution degree Cooling method Specifications Item Display Type Display Size Resolution Color Viewing Angle Backlight Backlight Capacity Brightness Touch Panel Sound Processor Sound Input Sound Output Flash Memory Operation RAM Backup RAM Backup Type Battery Capacity USB Port RS-232C RS-422/485 Ethernet CF Card SD Card Body Monitoring Sound Output Video Input Video Output Expansion IF Module VM I/F Certification IP Size (mm) Panel Cut (mm) Power Power Consumption (W) Weight (kg) iXP70-TTA DC: ±800V ±4kV (Contact discharge) 80 ~ 100MHz, 10V/m Power Module: 2 kV, Communication Interface: 1kV Free from corrosive gas and excessive dust 2,000m (6,562ft) or below 2 or under Natural air-cooling 28_29 Standard IEC 61131-2 IEC 61131-2 LSIS Standards IEC 61131-2, IEC 61000-4-2 IEC 61131-2, IEC 61000-4-3 IEC 61131-2, IEC 61000-4-4 iXP80-TTA iXP90-TTA TFT color LCD 26.4cm (10.4″) 30.7cm (12.1″) 38.1cm (15″) 800×600(SVGA) 800×600(SVGA) 1,024×768(XGA) 16bit/24bit Color (default 16bit) Left/Right: 80 deg. Up: 60 deg. Down: 80 deg. LED mode 60,000h 700 cd/㎡ 550 cd/㎡ 800 cd/㎡ Analogue resistive Magnetic buzzer (85dB) ARM Cortex-A8 Core (32bit RISC), 1GHz 1channel, stereo sound 1GB (Screen 128MB) 512MB 1MB Date/Time, Logging/Alarm/Recipe data, non-volatile device Around 3 years (upon operation at 25℃) 3 channels, USB 2.0 host (mouse, keyboard and USB memory driver supported) 1channel, USB 2.0 device (Project export/import to/from PC) 1 channel 1 channel, for both 422/485 1 channel, IEEE802.1a, 10Base-T/100Base-TX 1 slot (Compact Flash) 1 slot (SDHC support) Distance: Left/Right 1~1.5m, Front 40~50cm Angle: Up/Down- 100 degrees, Left/Right- 140 degrees (Infrared ray 5~20 microns detected) LINE-OUT 1channel sound Communication & I/O option module installed (to be provided in the future) 4-channel video input (to be provided in the future) CE, UL(cUL), KC IP65 270.5×212.2×57.0 313.0×239.0×57.0 395.0×294.0×60.0 259.0×201.0 301.5×227.5 383.5×282.5 AC100~240V, DC12/24V 42 42 42 2.2 2.4 3.9 Products XP Series 65,536 TFT color 4/10/20MB User memory, 128/512KB Backup memory Ethernet & serial communications support USB Host function to be used in various PC devices Up to 8 languages at a time and a batch-change of languages Offline simulations (Link to the XG5000 simulator) Dimensions [Unit: mm] XP30-BTE / TTE XP70-TTA / XP80-TTA XP30-BTA / TTA XP90-TTA XP50-TTA XGT Panel (iXP series/XP series) 30_31 General nformation No. 1 2 3 4 5 Description 0℃~+50℃ -20℃~+60℃ 10~85%RH, without dew condensation 10~85%RH, without dew condensation -20℃~+60℃ Acceleration Amplitude 3.5mm 9.8㎨ Continuous Vibration Amplitude Acceleration 1.75mm 4.9㎨ Item Ambient temperature Storage temperature Ambient humidity Storage humidity Frequency 5 ≤ f < 9㎐ 9 ≤ f ≤ 150㎐ Vibration Resistance Frequency 5 ≤ f < 9㎐ 9 ≤ f ≤ 150㎐ 6 Shock Resistance 7 Noise Resistance 8 9 10 11 Operating ambience Altitude Pollution degree Cooling method Standard Counts 10 times each direction (X, Y and Z) Maximum shock acceleration: 147㎨(15g) Authorization time: 11㎳ Pulse waveform: Half-sine wave pulse (3 times each of X,Y and Z) Square wave impulse noise AC: ±1,500V DC: ±1,000V Electrostatic discharge Voltage: 6 kV (Contact discharge) Radiated electromagnetic field noise 27 ~ 500MHz, 10V/m Fast transient/Burst noise Power module: 2 kV, Communication interface: 1kV Free from corrosive gas and excessive dust 2,000m (6,562ft) or below 2 or under Natural air-cooling IEC 61131-2 IEC 61131-2 LSIS Standards IEC 61131-2, IEC 61000-4-2 IEC 61131-2, IEC 61000-4-3 IEC 61131-2, IEC 61000-4-4 Specifications Model Type Display Element Screen Size Resolution Color Backlight Contrast Luminance Viewing Up/Down(Degree) Angle Left/Right(Degree) Touch Panel Movement LED Screen Data Memory Backup Data Ethernet USB Interface RS-232C Serial RS-422/485 CF Card Interface AUX Interface Certification Protection Size(W×H×D)mm Panel Cut (W×H)mm Weight (kg) Rated Voltage Permitted AC DC Power Voltage Power AC Consumption DC (W) XP30-BTA/DC XP30-BTE/DC XP30-TTE/DC XP30-TTA/DC Mono Mono Blue LCD 14cm (5.7”) 320×240 8-column Gray Scale 256 colors LED mode CCFL(LCD single body), Auto On/Off 50,000 hours Adjustable 230cd/㎡ XP70-TTA/AC XP70-TTA/DC XP50-TTA/DC XP80-TTA/AC XP80-TTA/DC 38cm (15”) 1024×768 50,000 hours 60,000 hours 60,000 hours Fixed 400cd/㎡ 480cd/㎡ 430cd/㎡ 400cd/㎡ 80/80 70/50 50/60 45/65 45/75 80/80 70/70 65/65 65/65 65/65 8-wire system, analogue 4-wire system, analogue Green: Normal RUN (Monitoring & drawing data download) Red: Error (Communication error & drawing data error) 10MB 10MB 4MB 512KB 128KB 512KB(saving logging/alarm data) 1ch, IEEE802.3, 1ch, IEEE802.3, 10/100Base-T 10/100Base-T USB Host X 2 USB Host X 1 USB Host X 2 2ch(1 port for PC communication) 1ch, 422/485 optional mode CF card (TAPE-1)×1 CF card (TAPE-1)*1 Optional Optional - 20/40 45/45 4MB 128KB USB Host X 1 - 181 x 140 x 56.5 0.62 181 x 140 x 66.5 181 x 140 x 56.5 155.5 x 123 0.75 0.62 CE, UL, KCC IP65 (Front Water Proof Structure) 240 x 174 x 73 181 x 140 x 66.5 228 x 158 1.4 0.75 DC 24V MIN 19.2 VDC, MAX 28.8 VDC 5 8.5 XP90-TTA/AC Color TFT Color LCD 31cm (12.1”) 21cm (8.4”) 26cm (10.4”) 640×480 800×600 65,536 colors CCFL(can be replaced), Auto On/Off 5 8.5 20 317 x 243 x 73 294 x 227 2.2 2.4 450cd/㎡ 60/50 75/75 20MB 395 x 294 x 73 383 x 282 3.9 AC100~220V, DC 24V AC100~220V MIN 85 VAC, MAX 264 VAC 40 37 46 27 30 - Products XP40 (7” Wide Type) 17.7cm (7”) TFT LCD-applied wide type LED Backlight adopted for enhanced contrast ratio and low-power PLC Ladder monitoring function: Only XGK/XBC supports Web Server* / Data Server* / Path-Through Function* Remote Viewer Function* CE, KC, UL/cUL certifications Screen editor : XP-Builder Functions that support only the TTA model Dimensions [Unit: mm] XGT Panel (iXP series/XP series) General nformation Item Description Ambient temperature 0℃~+50℃ Storage temperature Standard -20℃~+60℃ Ambient humidity 10~85%RH, without dew condensation Storage humidity 10~85%RH, without dew condensation Occasional Vibration Amplitude Acceleration Frequency Vibration resistance 5 ≤ f < 9㎐ - 3.5mm 9 ≤ f ≤ 150㎐ 9.8㎨ Continuous Vibration - Acceleration Amplitude Frequency Counts 10 times each direction (X, Y and Z) 5 ≤ f < 9㎐ Noise resistance Operating ambience Free from corrosive gas and excessive dust 2,000m (6,562ft) or below Altitude Specificat ions Pollution degree 2 or under Cooling method Natural air-cooling Item Display Type XP40-TTE/DC XP40-TTA/DC TFT color LCD Display Size 17.7cm (7inch) Resolution 800 x 480 pixels Color 256 colors 65,536 colors Left/Right: 65 deg. Up: 50 deg. Down: 60 deg. Display Angle LED mode (can be replaced) Backlight 30,000 hr. or more Backlight Capacity Brightness 280 cd/㎡ Touch Panel Analogue resistive Magnetic buzzer (87dB) Sound ARM920T (32bit RISC), 200MHz Processor Hardware accelerator Graphic Accelerator Memory Flash 16MB Operation RAM 32MB 64MB 128KB 512KB Backup RAM Backup Type 32MB Date/Time data, Logging/Alarm/Recipe data, non-volatile device Batter Capacity Around 3 years (Upon operation at 25℃) 1 channel, USB 2.0 (supports printer and USB memory driver) USB Host RS-232C Terminal block type RS-422/485 1 channel, IEEE802.3, 10Base-T / 100Base-TX Ethernet CE, UL(cUL), KC Certification IP65 203.5×153.5×41.5 IP Size (mm) 192×138 Panel Cut (mm) Power Power Consumption (W) Weight (kg) IEC 61131-2 1.75mm 4.9㎨ IEC 61131-2 Maximum shock acceleration: 147㎨(15g) Authorization time: 11㎳ Pulse waveform: Half-sine wave pulse (3 times each of X,Y and Z) DC: ±800V Square wave impulse noise LSIS Standards ±4kV (Contact discharge) Electrostatic discharge IEC 61131-2, IEC 61000-4-2 80 ~ 100MHz, 10V/m Radiated electromagnetic field noise IEC 61131-2, IEC 61000-4-3 Power module: 2 kV, Communication interface: 1kV Fast transient/Burst noise IEC 61131-2, IEC 61000-4-4 9 ≤ f ≤ 150㎐ Shock resistance 32_33 DC24V 4.5 or less 5.0 or less 0.8 0.81 Products List of Communication Drivers Manufacturer LSIS Mitsubishi OMRON Rockwell Controller XGK (Link) XGK (CPU) XGK (Ethernet) XGK (Ethernet/IP) XGI (Link) XGI (CPU) XGI (Ethernet) XGI (Ethernet/IP) XGR (Link) XGR (CPU) XGR (Ethernet) XGR (Ethernet/IP) XEC (Link) XEC (CPU) XEC (Ethernet) XEC (Ethernet/IP) XGB (Link) XGB (CPU) XGB (Ethernet) XGB (Ethernet/IP) GLOFA-GM (Link) GLOFA-GM (CPU) GLOFA-GM (Ethernet) MASTER-K (80,120,200,300,1000)S (Link) MASTER-K (80,120,200,300,1000)S (CPU) MASTER-K (200,300,1000)S (Ethernet) XGT Servo Inverter (LSBus) Inverter (MODBUS) User Defined Communication (Master - Serial/Ethernet) User Defined Communication (Slave - Ethernet) MELSEC-A (Link) MELSEC-A (CPU) MELSEC-FX (Link) MELSEC-FX (CPU) MELSEC-FX (Ethernet) MELSEC-Q (CPU) , *U Type excluded MELSEC-QnA,Q (Link) MELSEC-QnA,Q (Ethernet) MELSEC-QnU CPU Built-in Ethernet MELSERVO-J2 MELSERVO-J3 C/CV Host Link CS/CJ Series Host Link CS/CJ Series (Ethernet) CJ1/CJ2 (Ethernet/IP) SLC500 Series (DF1) ControlLogix/CompactLogix Series (DF1) MicroLogix Series (DF1) ControlLogix/CompactLogix Series Native (Ethernet/IP) Ethernet/IP MicroLogix Series (Ethernet/IP) Manufacturer Schneider Electric Industries RS Automation Siemens KDT Systems LS Mecapion GE Fanuc Panasonic Hyundai Elevator Daewon Parker Digital CANopen Slave Profibus DP Slave Delta Fuji Hanyoung CAS HIGEN SEW EURODRIVE Lenze YOKOKAWA BACnet Control Techniques KOYO KTURBO BYD Auto YASKAWA HITACHI KEYENCE DasaRobot Controller MODBUS RTU/ASCII Master MODBUS TCP/IP Master MODBUS RTU/ASCII Slave MODBUS TCP/IP Slave N/NX Series CCU NX Series CCU+ SIMATIC S7 MPI (PC Adaptor) SIMATIC S7 PPI SIMATIC S7 3964(R)/RK512 SIMATIC S7 (Ethernet) LOGO (Ethernet) SIMATIC S7 1200 (Ethernet) BP Series Loader CP Series Loader XP Series Loader KDT CIMON Serial (Link) VS/VP Servo Drive MXQ Series 90-30/70 SNP 90-30/70 SNP-X MINAS Servo FP Series (Link) SKY-RAV (Link) SKY-RAV (Ethernet) GSI Dedicated Controller Hi-Drive Memory Link CANopen Slave PROFIBUS DP Slave DVP Series MICREX-SX Series (Link) MICREX-SX Series (Ethernet) Temperature Controller Weight Indicator Servo MOVIDRIVE Serial Lecom A/B FA-M3 Series FA-M3 Series (Ethernet) IP Master CT Modbus RTU DirectNet Serial Turbo Blower MT508 BYD Dedicated Controller MEMOBUS RTU Master MP2000 Series (Ethernet) H Series (Link) H Series (Ethernet) KV-700/1000/3000/5000/5500 Serial KV-700/1000/3000/5000/5500 (Ethernet) DASA iM-SIGMA Series XGT Panel (iXP series/XP series) 34_35 Safety Instructions �For your safety, please read user's manual thoroughly before operating. �Contact the nearest authorized service facility for examination, repair, or adjustment. �Please contact qualified service technician when you need maintenance. Do not disassemble or repair by yourself ! �Any maintenance and inspection shall be performed by the personnel having expertise concerned. ⓒ 2006. LSIS Co., Ltd. All Rights Reserved. Overseas Branches HEAD OFFICE LS Tower, 127, LS-ro, Dongan-gu, Anyang-si, Gyeonggi-Do, 431-848, Korea ■ Southeast Asia ■ Europe ■ Turkey/Israel/CIS ■ Oceania ■ North America ■ Southwest Asia/Africa ■ Latin America ■ Middle East +82-2-2034-4888 +82-2-2034-4676 +82-2-2034-4879 +82-2-2034-4394 +82-2-2034-4471 +82-2-2034-4467 +82-2-2034-4286 +971-4-886-5360 [email protected] (Charles Hwang) [email protected] (Brian Choi) [email protected] (Daniel Kim) [email protected] (Kendra Cho) [email protected] (Paul Kwon) [email protected] (Henry Lee) [email protected] (Raul Chung) [email protected] (Lambert Choi) Overseas Subsidiaries LSIS(Shanghai) Co., Ltd. /CHINA 32nd Room 1~4, 32/F, Great Wall Building, No.3000 North Zhongshan Road, Putuo District, Shanghai, P.R. China Tel : 86-21-5237-9977(609) Fax : 86-21-5237-7189 LSIS(Dalian) Co., Ltd. /CHINA No. 15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian, P.R. China Tel : 86-411-8731-7542 Fax : 86-411-8730-7560 E-Mail : [email protected] LSIS(Wuxi) Co., Ltd./CHINA 102-A, National High & New Tech Industrial Development Area, Wuxi, Jiangsu, P.R. China Tel : 86-510-8534-6666 Fax : 86-510-8534-4078 E-Mail : [email protected] LS Hukai Electric(Hubei) Co., Ltd./CHINA No. 100, Tanjiahe Road, Dianjun District, Yichang City, Hubei Province, P.R. China Tel : 86-717-667-7536 Fax : 86-717-667-7222 E-Mail : [email protected] LS-VINA Industrial Systems Co., Ltd./VIETNAM Room 1311, 13th, M3-M4 Building 91 Nguyen Chi Thanh street, Hanoi, Vietnam Tel : 84-4-6275-8055 Fax : 86-21-5237-7189 LSIS(ME) FZE/U.A.E. LOB 19-205, JAFZA View Tower, Jebel Ali Free Zone, Dubai, United Arab Emirates Tel : 971-4-886-5360 Fax : 971-4-886-5361 E-Mail : [email protected] LSIS Europe B.V./NETHERLANDS 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands Tel : 31-20-654-1420 Fax : 31-20-654-1429 E-Mail : [email protected] LSIS Shanghai Office/CHINA Room E-G, 12th, Huamin Empire Plaza, No.726, West Yan'an Road, Shanghai, P.R. China Tel : 86-21-5237-9977(702) Fax : 86-21-5237-7189 LSIS Beijing Office/CHINA Room 2306, Building B Landgent Center, No.24 Middle Road, East 3rd Ring Road, Chaoyang District, Beijing, P.R. China Tel : 86-10-5761-3127 Fax : 86-10-5761-3128 E-Mail : [email protected] LSIS Guangzhou Office/CHINA Room 1403, 14th, New Poly Tower, 2 Zhongshan Liu Road, Guangzhou, P.R China Tel : 86-20-8326-6784 Fax : 86-20-8326-6287 E-Mail : [email protected] LSIS Qingdao Office/CHINA Room 2001, Galaxy Building, 29 ShanDong Road, ShiNan District, QingDao, ShanDong, P.R. China Tel : 86-532-8501-6058 Fax : 86-532-8501-6057 E-Mail : [email protected] LSIS Chengdu Office/CHINA Room1710, 17/F Huamin Empire Plaza, NO.1 Fuxin Road, Chengdu, P.R. China Tel : 86-28-8670-3201 Fax : 86-28-8670-3203 E-Mail : [email protected] LSIS ShenYang Office/CHINA Room 803, Hongyuan Building, 52 South Nanjing Road,Heping District, Shenyang, P.R. China Tel : 86-24-2321-9050 Fax : 86-24-8386-7210 E-Mail : [email protected] LSIS Jinan Office/CHINA Room 417, Chuangzhan Center, No. 201, Shanda Road, Lixia District, Jinan, Shandong, P. R. China Tel : 86-531-8263-8026 Fax : 86-531-8263-8027 E-Mail : [email protected] LSIS Tokyo Office/JAPAN 16th, Higashi-Kan, Akasaka Twin Tower, 2-17-22, Akasaka, Minato-ku, Tokyo, Japan Tel : 81-3-3582-9128 Fax : 81-3-3582-2667 LS-VINA Industrial Systems Hochiminh Office/VIETNAM 4th, Yoco Building, 41 Nguyen Thi Minh Khai Street, Hochiminh City, Vietnam Tel : 84-8-3822-7941 Fax : 81-84-8-3822-7942 E-Mail : [email protected] LSIS Detroit Office/U.S.A. 5700 Crooks Rd, Suite 211, Troy, MI 48098, United States of America Tel : 1-248-792-2637~8 Fax : 1-248-792-2642 E-Mail : [email protected] LSIS Gurgaon Office/INDIA 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India Tel : +0091-124-493-0070 Fax : 91-1244-930-066 E-Mail : [email protected] LSIS Japan Co., Ltd./JAPAN 16th, Higashi-Kan, Akasaka Twin Tower, 2-17-22, Akasaka, Minato-ku, Tokyo, Japan Tel : 81-3-3582-9128 Fax : 81-3-3582-2667 E-Mail : [email protected] LSIS USA Inc./U.S.A. 2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of America Tel : 847-941-8240 Fax : 847-941-8259 2014. 01 Specifications in this catalog are subject to change without notice due to continuous product development and improvement. Panel Series(E) 2014 01/ (01) 2014.01 Printed in Korea HumanPower