electromagnetic interference test report
Transcription
electromagnetic interference test report
ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ACCELERATOR CENTER SPACECRAFT INTERFACE UNIT (SIU), LAT-DS-01862 MIL-STD-461E (1999), SECTIONS CE102, RE101, RE102, RS101 AND RS103 MIL-STD-462 SECTIONS: CS102 (NOTICE 5 1986) AND CS06 (NOTICE 3 1971) TESTING IN ACCORDANCE WITH TEST PLAN TP05-83492-1 DATE OF ISSUE: NOVEMBER 3, 2005 PREPARED FOR: PREPARED BY: Stanford Linear Accelerator Center 2575 Sand Hill Road MS: 96 Menlo Park, CA 94025 Valerie Honsinger CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 P.O. No.: 0000056078 W.O. No.: 83492 Date of test: October 19 - 26, 2005 Report No.: MIL05-043 This report contains a total of 161 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, as identified herein. Page 1 of 161 Report No.: MIL05-043 TABLE OF CONTENTS Administrative Information .............................................................................................3 Approvals.........................................................................................................................4 Unit Under Test (UUT) Description ................................................................................5 Unit Under Test ...............................................................................................................5 Peripheral Devices ...........................................................................................................5 Summary of Results.........................................................................................................6 Report of Measurements ..................................................................................................8 CE102 - Conducted Emissions, Power Leads, 10kHz to 10MHz........................8 CECM – Conducted Emissions, Common Mode, DC to 150MHz .....................26 RE101 - Radiated Emissions, Magnetic Field, 30Hz to 100kHz.........................36 RE102 - Radiated Emissions, Electric Field, 10kHz to 18GHz ..........................56 CS06 - Conducted Susceptibility, Spikes on Power Leads .................................125 CS102 - Conducted Susceptibility, Power Leads, 10kHz to 10MHz ..................130 CSCM - Conducted Susceptibility, Common Mode, 30Hz to 150MHz..............137 RS101 - Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz ...................142 RS103 - Radiated Susceptibility, Electric Field, 10kHz to 18GHz .....................148 Test Log ...........................................................................................................................155 Page 2 of 161 Report No.: MIL05-043 ADMINISTRATIVE INFORMATION SCOPE: To demonstrate testing of the Spacecraft Interface Unit (SIU), LAT-DS-01862 with the requirements for MIL-STD-461E and MIL-STD-462D in accordance with test plan TP05-834921. CONTRACT NUMBERS: NA APPLICABLE DOCUMENTS: 1. MIL-STD-461E - Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference 2. MIL-STD-462E - .Measurements of Electromagnetic Interference Characteristics 3. MIL-STD-464A – Electromagnetic Environmental Effects Requirements for Systems 4. 433-RQMT-0005, Rev A – GLAST Observatory Electromagnetic Interference (EMI) Requirements Document, NASA/GSFC, Oct 6, 2003 5. MIL-STD-45662 Calibration Systems Requirements 6. LAT-MD-00408 - “LAT Instrument Performance Verification Plan”, SLAC 7. LAT-SS-00778 – LAT Environmental Specification, SLAC, M. Nordby 8. CKC Test Procedure: TP05-83492-1 MANUFACTURER: Stanford Linear Accelerator Center 2575 Sand Hill Road MS: 96 Menlo Park, CA 94025 REPRESENTATIVE: Dave Nelson TEST LOCATION: CKC Laboratories, Inc. 1120 Fulton Place Fremont, CA 94539 Page 3 of 161 Report No.: MIL05-043 FREMONT, CA MILITARY CHAMBER The CKC Laboratories, Inc. Fremont EMI Chamber used for the testing was a 16' x 16' x 10' high shielded enclosure designed to attenuate radio frequency noise over 80 dB up to 1GHz, and over 60 dB at 18GHz. The enclosure uses ferrite tiles with foam anechoic material in key areas to achieve uniform testing from 1MHz to 40GHz. Power brought into the room is filtered over 100 dB for frequencies over 14kHz. All emissions measurement equipment is operated from isolation transformers, which help eliminate the possibility of ground loops. All lighting in the laboratory is filtered to reduce electrical noise. In addition, incandescent lights are used during emissions testing to further reduce the potential for electrical noise. The ground plane in the chamber consists of a 3'3” x 12' x 0.020" thick copper sheet bonded to the shield room wall with 0.1 mW of bonding resistance. APPROVALS QUALITY ASSURANCE: TEST PERSONNEL: Steve Behm, Director of Engineering Services Amrinder Brar, Lab Manager Joyce Walker, Quality Assurance Administrative Manager Page 4 of 161 Report No.: MIL05-043 UNIT UNDER TEST (UUT) DESCRIPTION UNIT UNDER TEST Spacecraft Interface Unit (SIU) Manuf: Stanford Linear Model: LAT-DS-01862 Serial: GLAT 2508 PERIPHERAL DEVICES The UUT was tested with the following peripheral device(s): Power Supply Manuf: AEMC Instruments Model: AX502 Serial: PC70344 VME Crate Manuf: Dawn Model: 11-1011777-2119 Serial: 002563 Mouse Manuf: Model: Serial: Dell by Microsoft X06-08477 NA Keyboard Manuf: Model: Serial: Dell 04N454 TH-04N454-37171-33F-E488 Monitor Manuf: Model: Serial: Dell MX-D9J367-47605-379-AYKJ PC65341 PC Manuf: Model: Serial: Dell DHM JLJJ331 Page 5 of 161 Report No.: MIL05-043 SUMMARY OF RESULTS As received, the Stanford Linear Accelerator Center Spacecraft Interface Unit (SIU), LAT-DS01862 was tested to following standards and specifications: Test Description CE102 - Conducted Emissions, Power Leads, 10kHz to 10MHz CECM - Conducted Emissions, Common Mode, DC to 150 MHz RE101 – Radiated Emissions, 20Hz to 50kHz RE102 - Radiated Emissions, 10kHz to 18GHz CS06 – Conducted Susceptibility, Spikes on Power Leads CS102 – Conducted Susceptibility, Power Leads, 10kHz to 10MHz CSCM – Conducted Susceptibility, Common Mode, 30Hz to 150MHz Results Outcome No emissions exceeding the limit were observed from PASS 10kHz to 10MHz on the 28VDC Input Power Lead and on the 28VDC Return Lead with input power set to 28VDC. No emissions exceeding the limit were observed on the PASS 28VDC Input Power Lead and on the 28VDC Return Lead to 150MHz. No out of spec emissions were observed exceeding the 7cm and 50cm limits from 30Hz to 100kHz on the Back connectors, Left, Front, Right and Top sides of the UUT. The UUT exhibited no out of spec emissions from 10kHz to 30MHz in Vertical polarization and from 30MHz to 18GHz in Vertical and Horizontal antenna polarizations. The UUT exhibited no signs of susceptibility during the extent of the testing on the 28VDC Input Power Line, the 28VDC Return Line. PASS The UUT exhibited no signs of susceptibility during the extent of the testing from 10kHz to 10MHz on the 28VDC Power and 28VDC Return Lines. PASS The UUT exhibited no signs of susceptibility during the extent of the testing from 30Hz to 150MHz on the 28VDC Input Power Line, the 28VDC Return Line. PASS PASS PASS Page 6 of 161 Report No.: MIL05-043 Test Description RS101 - Radiated Susceptibility, Magnetic Field, 20Hz to 50kHz RS103 – Radiated Susceptibility, Electric Field, 10kHz to 18GHz Results Outcome The UUT showed no signs of susceptibility during the PASS extent of the testing from 30Hz to 50kHz on the front, back, right side, left side and top faces of the UUT at test levels exceeding the levels specified in Figure RS101-2. The UUT showed no signs of susceptibility during the PASS extent of the testing at 1V/m from 30MHz to 18GHz in horizontal and vertical antenna polarizations. Page 7 of 161 Report No.: MIL05-043 REPORT OF MEASUREMENTS CE102 - Conducted Emissions, Power Leads, 10kHz to 10MHz Test Equipment Function SA - E4446A Cable Cable RG214/U Andrew Cable Current Probe F-35 Oscilloscope Asset # 02668 P05309 02410 1184 00731 00697 S/N US44300408 None None CNT-195 296 US35420829 Cal Date 01/13/2005 08/01/2005 06/07/2004 01/03/2005 05/07/2003 08/31/2005 Cal Due 01/13/2007 08/01/2007 06/07/2006 01/03/2007 05/07/2005 08/31/2007 Test Procedure The signal generator was connected to the input of the LISN. The signal was injected a signal at 10kHz at 6dB below the limit line and the LISN output was measured on the oscilloscope. The check was repeated at 100kHz, 2MHz and 10MHz. The check was also repeated on all remaining LISNs. The UUT was powered up in standard operating mode. A test cable was connected from the monitor port on the 28VDC Input Power LISN through 20dB of attenuation to the measurement system. A 50Ω termination was placed on the monitor port of the other LISNs. The emissions were measured from 10kHz to 10MHz. Then, the test cable was moved to the 28VDC Return LISN and the 50Ω termination was placed on the other LISN monitor ports. The emissions were measured from 10kHz to 10MHz. Page 8 of 161 Report No.: MIL05-043 CE102 Conducted Emissions, Power Leads Pre-Calibration CE102 Conducted Emissions, Power Leads Test Setup Page 9 of 161 Report No.: MIL05-043 CE102 Conducted Emissions, Power Leads Closeup Seq. # 0 0 0 20 Test Description Conducted Emissions Conducted Emissions Conducted Emissions Conducted Emissions 21 Conducted Emissions Test Lead / Conditions Pre-Cal @ 10kHz Pre-Cal @ 2MHz Pre-Cal @ 10MHz Positive Lead / Grounded to copper table as it exits cage and chamber wall before coming into chamber. Return Lead / Grounded to copper table as it exits cage and chamber wall before coming into chamber. Page 10 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center CE102 MIL-STD-462 83492 Conducted Emissions Spacecraft Interface Unit Stanford Linear Stanford Linear Accelerator Center GLAT 2508 Equipment Under Test (* = EUT): Function Manufacturer Spacecraft Interface Unit* Stanford Linear Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: 10/20/2005 3:58:36 PM 0 A. Brar 28V DC Model # Stanford Linear Accelerator Center Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Pre-Cal Sweep. Signal at 10KHz. Injecting current which is 6dB below the limit though a 50 ohms load, and expecting to see -6dB +/-3dB from the limit. Transducer Legend: T1=Cable 2410 T3=CMP F-35 SN 296 T2=Cable P05309 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 10.000k 46.9 +0.1 -0.1 +10.9 dB Dist Table +0.0 Test Lead: Corr dBµV 57.8 Pre-Cal Spec Margin dBµV dB 66.0 -8.2 Polar Ant Pre-C 2 40.780k 20.6 +0.1 +0.0 +3.4 +0.0 24.1 66.0 -41.9 Pre-C 3 12.429k 8.9 +0.1 -0.1 +9.6 +0.0 18.5 66.0 -47.5 Pre-C 4 13.239k 8.2 +0.1 -0.1 +9.2 +0.0 17.4 66.0 -48.6 Pre-C 5 14.049k 7.0 +0.1 -0.1 +8.8 +0.0 15.8 66.0 -50.2 Pre-C Page 11 of 161 Report No.: MIL05-043 6 14.499k 6.9 +0.1 +0.0 +8.6 +0.0 15.6 66.0 -50.4 Pre-C 7 14.229k 6.3 +0.1 +0.0 +8.8 +0.0 15.2 66.0 -50.8 Pre-C 8 19.989k 7.9 +0.1 +0.0 +6.7 +0.0 14.7 66.0 -51.3 Pre-C 9 17.019k 5.4 +0.1 +0.0 +7.7 +0.0 13.2 66.0 -52.8 Pre-C 10 18.099k 5.8 +0.1 +0.0 +7.3 +0.0 13.2 66.0 -52.8 Pre-C 11 20.799k 6.1 +0.1 +0.0 +6.5 +0.0 12.7 66.0 -53.3 Pre-C 12 21.339k 5.4 +0.1 +0.0 +6.4 +0.0 11.9 66.0 -54.1 Pre-C 13 22.239k 5.6 +0.1 +0.0 +6.2 +0.0 11.9 66.0 -54.1 Pre-C 14 29.709k 4.8 +0.1 +0.0 +4.7 +0.0 9.6 66.0 -56.4 Pre-C 15 25.299k 3.6 +0.1 +0.0 +5.5 +0.0 9.2 66.0 -56.8 Pre-C 16 26.289k 3.3 +0.1 +0.0 +5.3 +0.0 8.7 66.0 -57.3 Pre-C 17 32.230k 4.2 +0.1 +0.0 +4.3 +0.0 8.6 66.0 -57.4 Pre-C 18 27.369k 2.5 +0.1 +0.0 +5.1 +0.0 7.7 66.0 -58.3 Pre-C 19 33.040k 3.2 +0.1 +0.0 +4.2 +0.0 7.5 66.0 -58.5 Pre-C 20 34.660k 3.3 +0.1 +0.0 +4.0 +0.0 7.4 66.0 -58.6 Pre-C 21 35.290k 2.8 +0.1 +0.0 +4.0 +0.0 6.9 66.0 -59.1 Pre-C 22 47.080k 3.5 +0.1 +0.1 +3.1 +0.0 6.8 66.0 -59.2 Pre-C 23 44.560k 3.3 +0.1 +0.0 +3.2 +0.0 6.6 66.0 -59.4 Pre-C 24 45.010k 2.9 +0.1 +0.1 +3.2 +0.0 6.3 66.0 -59.7 Pre-C 25 34.030k 1.9 +0.1 +0.0 +4.1 +0.0 6.1 66.0 -59.9 Pre-C 26 36.010k 2.0 +0.1 +0.0 +3.9 +0.0 6.0 66.0 -60.0 Pre-C Page 12 of 161 Report No.: MIL05-043 27 43.840k 2.6 +0.1 +0.0 +3.3 +0.0 6.0 66.0 -60.0 Pre-C 28 32.680k 1.2 +0.1 +0.0 +4.3 +0.0 5.6 66.0 -60.4 Pre-C 29 47.800k 2.3 +0.1 +0.1 +3.0 +0.0 5.5 66.0 -60.5 Pre-C 30 49.420k 2.2 +0.1 +0.1 +2.9 +0.0 5.3 66.0 -60.7 Pre-C Page 13 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center CE102 MIL-STD-462 83492 Conducted Emissions Spacecraft Interface Unit Stanford Linear Stanford Linear Accelerator Center GLAT 2508 Equipment Under Test (* = EUT): Function Manufacturer Spacecraft Interface Unit* Stanford Linear Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: 10/20/2005 4:27:49 PM 0 A. Brar 28V DC Model # Stanford Linear Accelerator Center Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Pre-Cal Sweep. Signal at 2MHz. Injecting current which is 6dB below the limit though a 50 ohms load, and expecting to see -6dB +/-3dB from the limit. Transducer Legend: T1=Cable 2410 T3=4' Cable AN 01184 T2=Cable P05309 T4=CMP F-35 SN 296 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 1.996M 97.4 +0.1 +0.0 +0.0 T4 Dist dB Table +1.2 +0.0 Test Lead: Corr dBµV 98.7 Pre-Cal Spec Margin dBµV dB 105.0 -6.3 Polar Ant Pre-C 2 5.988M 54.5 +0.1 +0.0 +0.0 +1.0 +0.0 55.6 85.1 -29.5 Pre-C 3 7.983M 47.2 +0.2 +0.1 +0.0 +1.0 +0.0 48.5 82.3 -33.8 Pre-C 4 9.985M 43.6 +0.2 +0.1 +0.0 +1.0 +0.0 44.9 80.0 -35.1 Pre-C 5 40.060k 24.6 +0.1 +0.0 +0.0 +3.5 +0.0 28.2 66.0 -37.8 Pre-C Page 14 of 161 Report No.: MIL05-043 6 80.111k 23.2 +0.0 +0.0 +0.1 +2.2 +0.0 25.5 66.0 -40.5 Pre-C 7 3.992M 49.1 +0.2 +0.0 +0.1 +1.1 +0.0 50.5 92.0 -41.5 Pre-C 8 39.340k 19.9 +0.1 +0.0 +0.0 +3.6 +0.0 23.6 66.0 -42.4 Pre-C 9 10.899k 13.1 +0.1 -0.1 +0.0 +10.4 +0.0 23.5 66.0 -42.5 Pre-C 10 12.249k 13.1 +0.1 -0.1 +0.0 +9.7 +0.0 22.8 66.0 -43.2 Pre-C 11 64.360k 19.5 +0.0 +0.0 +0.0 +2.5 +0.0 22.0 66.0 -44.0 Pre-C 12 69.580k 19.5 +0.1 +0.0 +0.0 +2.4 +0.0 22.0 66.0 -44.0 Pre-C 13 18.189k 14.5 +0.1 +0.0 +0.0 +7.3 +0.0 21.9 66.0 -44.1 Pre-C 14 24.489k 15.9 +0.1 +0.0 +0.0 +5.7 +0.0 21.7 66.0 -44.3 Pre-C 15 13.509k 12.5 +0.1 -0.1 +0.0 +9.1 +0.0 21.6 66.0 -44.4 Pre-C 16 53.110k 18.6 +0.1 +0.1 +0.0 +2.8 +0.0 21.6 66.0 -44.4 Pre-C 17 14.769k 12.9 +0.1 +0.0 +0.0 +8.5 +0.0 21.5 66.0 -44.5 Pre-C 18 32.680k 16.9 +0.1 +0.0 +0.0 +4.3 +0.0 21.3 66.0 -44.7 Pre-C 19 76.150k 18.9 +0.0 +0.0 +0.1 +2.3 +0.0 21.3 66.0 -44.7 Pre-C 20 13.779k 12.2 +0.1 -0.1 +0.0 +9.0 +0.0 21.2 66.0 -44.8 Pre-C 21 15.669k 12.8 +0.1 +0.0 +0.0 +8.2 +0.0 21.1 66.0 -44.9 Pre-C 22 24.039k 15.3 +0.1 +0.0 +0.0 +5.7 +0.0 21.1 66.0 -44.9 Pre-C 23 85.511k 18.8 +0.1 +0.0 +0.0 +2.1 +0.0 21.0 66.0 -45.0 Pre-C 24 20.349k 14.2 +0.1 +0.0 +0.0 +6.6 +0.0 20.9 66.0 -45.1 Pre-C 25 59.410k 17.9 +0.0 +0.0 +0.0 +2.6 +0.0 20.5 66.0 -45.5 Pre-C 26 87.761k 18.1 +0.1 +0.0 +0.0 +2.1 +0.0 20.3 66.0 -45.7 Pre-C Page 15 of 161 Report No.: MIL05-043 27 72.550k 17.8 +0.1 +0.0 +0.0 +2.3 +0.0 20.2 66.0 -45.8 Pre-C 28 83.891k 17.9 +0.0 +0.0 +0.1 +2.2 +0.0 20.2 66.0 -45.8 Pre-C 29 88.661k 18.0 +0.1 +0.0 +0.0 +2.1 +0.0 20.2 66.0 -45.8 Pre-C 30 45.280k 16.7 +0.1 +0.1 +0.0 +3.2 +0.0 20.1 66.0 -45.9 Pre-C Page 16 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center CE102 MIL-STD-462 83492 Conducted Emissions Spacecraft Interface Unit Stanford Linear Stanford Linear Accelerator Center GLAT 2508 Equipment Under Test (* = EUT): Function Manufacturer Spacecraft Interface Unit* Stanford Linear Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: 10/20/2005 4:34:28 PM 0 A. Brar 28V DC Model # Stanford Linear Accelerator Center Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Pre-Cal Sweep. Signal at 10MHz. Injecting current which is 6dB below the limit though a 50 ohms load, and expecting to see -6dB +/-3dB from the limit. Transducer Legend: T1=Cable 2410 T3=CMP F-35 SN 296 T2=Cable P05309 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 9.903M 73.2 +0.2 +0.1 +1.0 dB Dist Table +0.0 Test Lead: Corr dBµV 74.5 Pre-Cal Spec Margin dBµV dB 80.1 -5.6 Polar Ant Pre-C 2 40.330k 20.4 +0.1 +0.0 +3.5 +0.0 24.0 66.0 -42.0 Pre-C 3 10.539k 8.7 +0.1 -0.1 +10.6 +0.0 19.3 66.0 -46.7 Pre-C 4 11.169k 7.0 +0.1 -0.1 +10.2 +0.0 17.2 66.0 -48.8 Pre-C 5 10.989k 6.6 +0.1 -0.1 +10.3 +0.0 16.9 66.0 -49.1 Pre-C Page 17 of 161 Report No.: MIL05-043 6 12.159k 7.1 +0.1 -0.1 +9.7 +0.0 16.8 66.0 -49.2 Pre-C 7 12.879k 7.2 +0.1 -0.1 +9.4 +0.0 16.6 66.0 -49.4 Pre-C 8 13.149k 7.4 +0.1 -0.1 +9.2 +0.0 16.6 66.0 -49.4 Pre-C 9 15.489k 7.6 +0.1 +0.0 +8.2 +0.0 15.9 66.0 -50.1 Pre-C 10 15.849k 7.7 +0.1 +0.0 +8.1 +0.0 15.9 66.0 -50.1 Pre-C 11 15.039k 6.5 +0.1 +0.0 +8.4 +0.0 15.0 66.0 -51.0 Pre-C 12 16.209k 6.0 +0.1 +0.0 +8.0 +0.0 14.1 66.0 -51.9 Pre-C 13 17.469k 6.1 +0.1 +0.0 +7.5 +0.0 13.7 66.0 -52.3 Pre-C 14 18.369k 6.3 +0.1 +0.0 +7.2 +0.0 13.6 66.0 -52.4 Pre-C 15 20.619k 6.0 +0.1 +0.0 +6.5 +0.0 12.6 66.0 -53.4 Pre-C 16 22.509k 6.4 +0.1 +0.0 +6.1 +0.0 12.6 66.0 -53.4 Pre-C 17 21.789k 5.2 +0.1 +0.0 +6.3 +0.0 11.6 66.0 -54.4 Pre-C 18 23.769k 5.7 +0.1 +0.0 +5.8 +0.0 11.6 66.0 -54.4 Pre-C 19 25.839k 5.5 +0.1 +0.0 +5.4 +0.0 11.0 66.0 -55.0 Pre-C 20 25.209k 4.3 +0.1 +0.0 +5.5 +0.0 9.9 66.0 -56.1 Pre-C 21 24.669k 4.0 +0.1 +0.0 +5.6 +0.0 9.7 66.0 -56.3 Pre-C 22 33.670k 5.2 +0.1 +0.0 +4.2 +0.0 9.5 66.0 -56.5 Pre-C 23 26.289k 3.4 +0.1 +0.0 +5.3 +0.0 8.8 66.0 -57.2 Pre-C 24 38.080k 4.5 +0.1 +0.0 +3.7 +0.0 8.3 66.0 -57.7 Pre-C 25 30.249k 3.4 +0.1 +0.0 +4.6 +0.0 8.1 66.0 -57.9 Pre-C 26 36.100k 2.9 +0.1 +0.0 +3.9 +0.0 6.9 66.0 -59.1 Pre-C Page 18 of 161 Report No.: MIL05-043 27 48.250k 3.7 +0.1 +0.1 +3.0 +0.0 6.9 66.0 -59.1 Pre-C 28 31.959k 1.8 +0.1 +0.0 +4.4 +0.0 6.3 66.0 -59.7 Pre-C 29 32.770k 1.9 +0.1 +0.0 +4.3 +0.0 6.3 66.0 -59.7 Pre-C 30 45.370k 2.0 +0.1 +0.1 +3.2 +0.0 5.4 66.0 -60.6 Pre-C Page 19 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center CE102 MIL-STD-462 83492 Conducted Emissions Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/20/2005 4:42:12 PM 20 A. Brar 28V DC Model # SIU S/N GLAT 2508 Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Cable 2410 T3=CMP F-35 SN 296 T2=Cable P05309 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 12.339k 52.8 +0.1 -0.1 +9.6 dB Dist Table +0.0 Test Lead: Positive Corr Spec Margin dBµV dBµV dB 62.4 66.0 -3.6 Polar Ant Posit 2 14.229k 52.2 +0.1 +0.0 +8.8 +0.0 61.1 66.0 -4.9 Posit 3 10.629k 50.5 +0.1 -0.1 +10.5 +0.0 61.0 66.0 -5.0 Posit 4 17.829k 51.7 +0.1 +0.0 +7.4 +0.0 59.2 66.0 -6.8 Posit 5 19.719k 49.5 +0.1 +0.0 +6.8 +0.0 56.4 66.0 -9.6 Posit Page 20 of 161 Report No.: MIL05-043 6 23.319k 46.9 +0.1 +0.0 +5.9 +0.0 52.9 66.0 -13.1 Posit 7 21.429k 43.3 +0.1 +0.0 +6.3 +0.0 49.7 66.0 -16.3 Posit 8 95.231k 46.9 +0.0 +0.0 +2.0 +0.0 48.9 66.0 -17.1 Posit 9 26.919k 43.0 +0.1 +0.0 +5.2 +0.0 48.3 66.0 -17.7 Posit 10 25.029k 37.4 +0.1 +0.0 +5.5 +0.0 43.0 66.0 -23.0 Posit 11 46.360k 38.7 +0.1 +0.1 +3.1 +0.0 42.0 66.0 -24.0 Posit 12 28.629k 34.1 +0.1 +0.0 +4.8 +0.0 39.0 66.0 -27.0 Posit 13 30.519k 34.4 +0.1 +0.0 +4.5 +0.0 39.0 66.0 -27.0 Posit 14 97.031k 36.8 +0.0 +0.0 +2.0 +0.0 38.8 66.0 -27.2 Posit 15 93.431k 33.9 +0.1 +0.0 +2.0 +0.0 36.0 66.0 -30.0 Posit 16 10.359k 25.0 +0.1 -0.1 +10.7 +0.0 35.7 66.0 -30.3 Posit 17 67.780k 30.8 +0.1 +0.0 +2.4 +0.0 33.3 66.0 -32.7 Posit 18 13.239k 23.2 +0.1 -0.1 +9.2 +0.0 32.4 66.0 -33.6 Posit 19 32.230k 27.8 +0.1 +0.0 +4.3 +0.0 32.2 66.0 -33.8 Posit 20 16.389k 24.1 +0.1 +0.0 +7.9 +0.0 32.1 66.0 -33.9 Posit 21 49.150k 29.0 +0.1 +0.1 +2.9 +0.0 32.1 66.0 -33.9 Posit 22 19.899k 25.2 +0.1 +0.0 +6.7 +0.0 32.0 66.0 -34.0 Posit 23 20.349k 25.2 +0.1 +0.0 +6.6 +0.0 31.9 66.0 -34.1 Posit 24 21.069k 24.0 +0.1 +0.0 +6.4 +0.0 30.5 66.0 -35.5 Posit 25 16.659k 22.0 +0.1 +0.0 +7.8 +0.0 29.9 66.0 -36.1 Posit 26 24.399k 24.1 +0.1 +0.0 +5.7 +0.0 29.9 66.0 -36.1 Posit Page 21 of 161 Report No.: MIL05-043 27 18.099k 22.4 +0.1 +0.0 +7.3 +0.0 29.8 66.0 -36.2 Posit 28 20.169k 23.0 +0.1 +0.0 +6.7 +0.0 29.8 66.0 -36.2 Posit 29 42.940k 25.4 +0.1 +0.0 +3.3 +0.0 28.8 66.0 -37.2 Posit 30 50.230k 25.4 +0.1 +0.1 +2.9 +0.0 28.5 66.0 -37.5 Posit Page 22 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center CE102 MIL-STD-462 83492 Conducted Emissions Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Manufacturer Stanford Linear Accelerator Center* Stanford Linear Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: 10/20/2005 4:46:35 PM 21 A. Brar 28V DC Model # SIU S/N GLAT 2508 Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Cable 2410 T3=CMP F-35 SN 296 T2=Cable P05309 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 10.179k 52.3 +0.1 -0.1 +10.8 dB Dist Table +0.0 Test Lead: Corr dBµV 63.1 DC Return Spec Margin dBµV dB 66.0 -2.9 Polar Ant DC Re 2 13.419k 52.9 +0.1 -0.1 +9.1 +0.0 62.0 66.0 -4.0 DC Re 3 15.489k 52.2 +0.1 +0.0 +8.2 +0.0 60.5 66.0 -5.5 DC Re 4 17.289k 52.1 +0.1 +0.0 +7.6 +0.0 59.8 66.0 -6.2 DC Re 5 11.889k 49.6 +0.1 -0.1 +9.9 +0.0 59.5 66.0 -6.5 DC Re 6 19.089k 48.4 +0.1 +0.0 +7.0 +0.0 55.5 66.0 -10.5 DC Re Page 23 of 161 Report No.: MIL05-043 7 20.979k 48.1 +0.1 +0.0 +6.5 +0.0 54.7 66.0 -11.3 DC Re 8 95.681k 43.6 +0.0 +0.0 +2.0 +0.0 45.6 66.0 -20.4 DC Re 9 22.689k 38.5 +0.1 +0.0 +6.0 +0.0 44.6 66.0 -21.4 DC Re 10 26.289k 38.1 +0.1 +0.0 +5.3 +0.0 43.5 66.0 -22.5 DC Re 11 28.179k 38.4 +0.1 +0.0 +4.9 +0.0 43.4 66.0 -22.6 DC Re 12 94.691k 40.7 +0.1 +0.0 +2.0 +0.0 42.8 66.0 -23.2 DC Re 13 46.090k 38.7 +0.1 +0.1 +3.1 +0.0 42.0 66.0 -24.0 DC Re 14 31.779k 33.4 +0.1 +0.0 +4.4 +0.0 37.9 66.0 -28.1 DC Re 15 47.440k 34.5 +0.1 +0.1 +3.0 +0.0 37.7 66.0 -28.3 DC Re 16 92.801k 33.6 +0.1 +0.0 +2.0 +0.0 35.7 66.0 -30.3 DC Re 17 13.149k 24.8 +0.1 -0.1 +9.2 +0.0 34.0 66.0 -32.0 DC Re 18 10.899k 22.8 +0.1 -0.1 +10.4 +0.0 33.2 66.0 -32.8 DC Re 19 72.190k 30.5 +0.1 +0.0 +2.4 +0.0 33.0 66.0 -33.0 DC Re 20 14.949k 24.2 +0.1 +0.0 +8.5 +0.0 32.8 66.0 -33.2 DC Re 21 10.449k 21.7 +0.1 -0.1 +10.6 +0.0 32.3 66.0 -33.7 DC Re 22 11.259k 22.0 +0.1 -0.1 +10.2 +0.0 32.2 66.0 -33.8 DC Re 23 11.709k 22.3 +0.1 -0.1 +9.9 +0.0 32.2 66.0 -33.8 DC Re 24 29.889k 27.5 +0.1 +0.0 +4.6 +0.0 32.2 66.0 -33.8 DC Re 25 21.159k 25.3 +0.1 +0.0 +6.4 +0.0 31.8 66.0 -34.2 DC Re 26 19.719k 24.3 +0.1 +0.0 +6.8 +0.0 31.2 66.0 -34.8 DC Re Page 24 of 161 Report No.: MIL05-043 27 24.579k 25.5 +0.1 +0.0 +5.6 +0.0 31.2 66.0 -34.8 DC Re 28 23.139k 24.7 +0.1 +0.0 +5.9 +0.0 30.7 66.0 -35.3 DC Re 29 21.519k 24.2 +0.1 +0.0 +6.3 +0.0 30.6 66.0 -35.4 DC Re 30 15.669k 22.1 +0.1 +0.0 +8.2 +0.0 30.4 66.0 -35.6 DC Re Page 25 of 161 Report No.: MIL05-043 CECM – Conducted Emissions, Common Mode, DC to 150MHz Test Equipment Equipment Oscilloscope Manufacturer HP Model # 54615B Serial # US35420828 Asset # 00697 Cal Date 8/31/03 Cal Due 8/31/07 Test Procedure Line to Chassis Ground: While the EUT was up and running in high noise mode, the Test Engineer connected an oscilloscope from DC Line to chassis ground using 150MHz BW setting. Changed the time scale on the oscilloscope from 1ns/division to 5s/divison and captured the noise plots. Return to Chassis Ground: While the EUT was up and running in high noise mode, the Test Engineer connected an oscilloscope from Return Line to chassis ground using 150MHz BW setting. Changed the time scale on the oscilloscope from 1ns/division to 5s/divison and captured the noise plots. Conducted Emissions, Common Mode Page 26 of 161 Report No.: MIL05-043 CECM DC Line 5s/Div DC Line 200ms/Div Page 27 of 161 Report No.: MIL05-043 DC Line 10ms/Div DC Line 2ms/Div Page 28 of 161 Report No.: MIL05-043 DC Line 100us/Div DC Line 1ns/Div Page 29 of 161 Report No.: MIL05-043 DC Line 5ns/Div DC Line 1ns/Div Page 30 of 161 Report No.: MIL05-043 DC Return 1ns/Div DC Return 5ns/Div Page 31 of 161 Report No.: MIL05-043 DC Return 20ns/Div DC Return 5us/Div Page 32 of 161 Report No.: MIL05-043 DC Return 200us/Div DC Return 5ms/Div Page 33 of 161 Report No.: MIL05-043 DC Return 50ms/Div DC Return 1s/Div Page 34 of 161 Report No.: MIL05-043 DC Return 5s/Div Page 35 of 161 Report No.: MIL05-043 RE101 - Radiated Emissions, Magnetic Field, 30Hz to 100kHz Test Equipment Function SA - E4446A Sig Gen - 2022D Cable Cable RG214/U Andrew Cable- CNT-195 Magnetic Loop Sensor - 7334-1 Asset # 02668 00727 P05309 02410 01189 00170 S/N US44300408 119190-018 None None None 170 Cal Date 01/13/2005 11/15/2004 08/01/2005 06/07/2004 04/12/2004 03/04/2005 Cal Due 01/13/2007 11/15/2006 08/01/2007 06/07/2006 04/12/2006 03/04/2007 Test Procedure A signal generator was connected into the measurement system. The test engineer performed a path loss check by injecting a signal at 50kHz that was 6dB below the limit line and measuring the resulting emission on the spectrum analyzer. Then, the signal generator was removed and the test cable was connected from the loop sensor to the spectrum analyzer. The UUT was powered up in standard operating mode. The loop was placed 7cm from the front side of the UUT chassis and a scan was performed. Then, the loop was placed 7cm from the backside of the UUT and the scan was repeated. Full scans were also performed on the top, left and right sides of the UUT. Page 36 of 161 Report No.: MIL05-043 RE101 Radiated Emissions, Magnetic Field Path Check RE101 Radiated Emissions, Magnetic Field Test Setup Page 37 of 161 Report No.: MIL05-043 Seq. # 0 22 Test Description Radiated Emissions Radiated Emissions 23 Radiated Emissions 24 Radiated Emissions 25 Radiated Emissions 26 Radiated Emissions Test Lead or Location / Conditions Path Check @ 50kHz Back Side – Connectors / Power Cable is grounded to copper table as it exits cage and to chamber wall before coming into chamber. Left Side / Power Cable is grounded to copper table as it exits cage and to chamber wall before coming into chamber. Front Side / Power Cable is grounded to copper table as it exits cage and to chamber wall before coming into chamber. Right Side / Power Cable is grounded to copper table as it exits cage and to chamber wall before coming into chamber. Top Side / Power Cable is grounded to copper table as it exits cage and to chamber wall before coming into chamber. Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE101 Test Limit 82840 Radiated Scan Date: Time: Sequence#: Tested By: 10/21/2005 1:15:23 PM 0 A. Brar Equipment Under Test (* = EUT): Function Manufacturer Model # S/N Support Devices: Function Model # S/N Manufacturer Test Conditions / Notes: Path Check Sweep. Signal at 50KHz. 52 (spec limit) - 6dB - 27.5 (Antenna Factor) = 18.5dBuV signal level. Transducer Legend: T1=3.5' Cable AN 01189 T3=Cable 2410 T2=Cable P05309 T4=Loop Sensor 7334-1 dBpT Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 45.957k 19.6 +0.0 +0.1 +0.1 Test Distance: T4 Dist Corr dB Table dBpt +27.7 +0.0 47.5 None Spec dBpt 52.7 Margin dB -5.2 Polar Ant None 2 40.471k 15.1 +0.0 +0.0 +0.1 +27.9 +0.0 43.1 53.8 -10.7 None 3 .060k 18.3 +0.0 +0.0 +0.0 +75.4 +0.0 93.7 110.4 -16.7 None Page 38 of 161 Report No.: MIL05-043 4 .179k 17.0 +0.0 +0.0 +0.0 +66.7 +0.0 83.7 100.9 -17.2 None 5 .299k 12.8 +0.0 +0.0 +0.0 +62.2 +0.0 75.0 96.5 -21.5 None 6 37.788k 2.8 +0.0 +0.0 +0.1 +28.0 +0.0 30.9 54.4 -23.5 None 7 47.839k -0.6 +0.0 +0.1 +0.1 +27.6 +0.0 27.2 52.4 -25.2 None 8 35.626k 0.6 +0.0 +0.0 +0.1 +28.1 +0.0 28.8 54.9 -26.1 None 9 20.610k 3.6 +0.0 +0.0 +0.1 +29.8 +0.0 33.5 59.7 -26.2 None 10 29.139k 1.6 +0.0 +0.0 +0.1 +28.6 +0.0 30.3 56.7 -26.4 None 11 32.423k 1.0 +0.0 +0.0 +0.1 +28.3 +0.0 29.4 55.8 -26.4 None 12 33.103k 0.7 +0.0 +0.0 +0.1 +28.3 +0.0 29.1 55.6 -26.5 None 13 34.345k 0.5 +0.0 +0.0 +0.1 +28.2 +0.0 28.8 55.3 -26.5 None 14 15.965k 4.3 +0.0 +0.0 +0.1 +30.8 +0.0 35.2 61.9 -26.7 None 15 23.894k 2.2 +0.0 +0.0 +0.1 +29.3 +0.0 31.6 58.4 -26.8 None 16 27.858k 1.3 +0.0 +0.0 +0.1 +28.8 +0.0 30.2 57.1 -26.9 None 17 10.159k 4.3 +0.1 -0.1 +0.1 +33.4 +0.0 37.8 65.9 -28.1 None 18 .239k 1.2 +0.0 +0.0 +0.0 +64.2 +0.0 65.4 98.4 -33.0 None 19 .119k 1.2 +0.0 +0.0 +0.0 +70.2 +0.0 71.4 104.5 -33.1 None 20 .420k -0.5 +0.0 +0.0 +0.0 +59.3 +0.0 58.8 93.5 -34.7 None 21 1.119k -1.0 +0.0 +0.0 +0.0 +51.3 +0.0 50.3 85.0 -34.7 None 22 1.231k -1.0 +0.0 +0.0 +0.0 +50.5 +0.0 49.5 84.2 -34.7 None 23 .539k -0.6 +0.0 +0.0 +0.0 +57.2 +0.0 56.6 91.4 -34.8 None 24 .112k -1.3 +0.0 +0.0 +0.0 +70.7 +0.0 69.4 105.0 -35.6 None Page 39 of 161 Report No.: MIL05-043 25 3.658k -2.3 +0.0 +0.0 +0.0 +41.4 +0.0 39.1 74.7 -35.6 None 26 .359k -1.5 +0.0 +0.0 +0.0 +60.7 +0.0 59.2 94.9 -35.7 None 27 .658k -1.7 +0.0 +0.0 +0.0 +55.6 +0.0 53.9 89.6 -35.7 None 28 3.082k -2.5 +0.0 +0.0 +0.0 +42.8 +0.0 40.3 76.2 -35.9 None 29 3.794k -3.1 +0.0 +0.0 +0.0 +41.0 +0.0 37.9 74.4 -36.5 None 30 3.330k -3.3 +0.0 +0.0 +0.0 +42.2 +0.0 38.9 75.5 -36.6 None Page 40 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE101 Test Limit 82840 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/21/2005 1:58:11 PM 22 A. Brar Model # SIU Support Devices: Function PC Monitor Manufacturer Dell Dell Keyboard Dell Model # DHM MX-D9J367-47605-379AYKJ 04N454 Mouse VME Crate Power Supply Dell by Microsoft Dawn AEMC Instruments X06-08477 11-1011777-2119 AX502 S/N GLAT 2508 S/N JLJJ331 PC65341 TH-04N454-37171-33FE488 none 002563 PC70344 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Back Side - Connectors Transducer Legend: T1=3.5' Cable AN 01189 T3=Cable 2410 T2=Cable P05309 T4=Loop Sensor 7334-1 dBpT Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 40.551k 11.6 +0.0 +0.0 +0.1 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBpt dBpt dB +27.9 +0.0 39.6 53.8 -14.2 Polar Ant Magne 2 .056k 19.7 +0.0 +0.0 +0.0 +76.0 +0.0 95.7 111.1 -15.4 Magne 3 47.398k -0.7 +0.0 +0.1 +0.1 +27.6 +0.0 27.1 52.5 -25.4 Magne 4 17.687k 4.7 +0.0 +0.0 +0.1 +30.4 +0.0 35.2 61.0 -25.8 Magne 5 9.999k 6.4 +0.0 +0.0 +0.1 +33.5 +0.0 40.0 66.0 -26.0 Magne Page 41 of 161 Report No.: MIL05-043 6 14.444k 5.3 +0.0 +0.0 +0.1 +31.2 +0.0 36.6 62.8 -26.2 Magne 7 11.681k 5.5 +0.1 -0.1 +0.1 +32.5 +0.0 38.1 64.6 -26.5 Magne 8 21.811k 2.8 +0.0 +0.0 +0.1 +29.6 +0.0 32.5 59.2 -26.7 Magne 9 26.136k 1.7 +0.0 +0.0 +0.1 +29.0 +0.0 30.8 57.6 -26.8 Magne 10 27.778k 1.4 +0.0 +0.0 +0.1 +28.8 +0.0 30.3 57.1 -26.8 Magne 11 33.904k 0.3 +0.0 +0.0 +0.1 +28.2 +0.0 28.6 55.4 -26.8 Magne 12 31.021k 0.3 +0.0 +0.0 +0.1 +28.4 +0.0 28.8 56.1 -27.3 Magne 13 .110k 6.4 +0.0 +0.0 +0.0 +70.9 +0.0 77.3 105.2 -27.9 Magne 14 .180k 3.2 +0.0 +0.0 +0.0 +66.6 +0.0 69.8 100.9 -31.1 Magne 15 .220k 1.4 +0.0 +0.0 +0.0 +64.9 +0.0 66.3 99.1 -32.8 Magne 16 1.792k 0.7 +0.0 +0.0 +0.0 +47.4 +0.0 48.1 80.9 -32.8 Magne 17 1.600k 0.2 +0.0 +0.0 +0.0 +48.3 +0.0 48.5 81.9 -33.4 Magne 18 .330k 0.7 +0.0 +0.0 +0.0 +61.4 +0.0 62.1 95.6 -33.5 Magne 19 1.055k 0.0 +0.0 +0.0 +0.0 +51.7 +0.0 51.7 85.5 -33.8 Magne 20 1.456k -0.4 +0.0 +0.0 +0.0 +49.1 +0.0 48.7 82.7 -34.0 Magne 21 .299k -0.1 +0.0 +0.0 +0.0 +62.3 +0.0 62.2 96.5 -34.3 Magne 22 3.450k -0.9 +0.0 +0.0 +0.0 +41.8 +0.0 40.9 75.2 -34.3 Magne 23 1.944k -1.3 +0.0 +0.0 +0.0 +46.7 +0.0 45.4 80.2 -34.8 Magne 24 3.346k -1.4 +0.0 +0.0 +0.0 +42.1 +0.0 40.7 75.5 -34.8 Magne 25 4.459k -1.7 +0.0 +0.0 +0.0 +39.7 +0.0 38.0 73.0 -35.0 Magne 26 1.271k -1.4 +0.0 +0.0 +0.0 +50.2 +0.0 48.8 83.9 -35.1 Magne Page 42 of 161 Report No.: MIL05-043 27 9.387k -2.6 +0.0 +0.0 +0.1 +33.9 +0.0 31.4 66.5 -35.1 Magne 28 4.796k -1.8 +0.0 +0.0 +0.0 +39.0 +0.0 37.2 72.4 -35.2 Magne 29 8.777k -2.3 +0.0 +0.0 +0.0 +34.2 +0.0 31.9 67.1 -35.2 Magne 30 9.203k -2.6 +0.0 +0.0 +0.1 +34.0 +0.0 31.5 66.7 -35.2 Magne Page 43 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE101 Test Limit 82840 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/21/2005 2:05:28 PM 23 A. Brar Model # SIU Support Devices: Function PC Monitor Manufacturer Dell Dell Keyboard Dell Model # DHM MX-D9J367-47605-379AYKJ 04N454 Mouse VME Crate Power Supply Dell by Microsoft Dawn AEMC Instruments X06-08477 11-1011777-2119 AX502 S/N GLAT 2508 S/N JLJJ331 PC65341 TH-04N454-37171-33FE488 none 002563 PC70344 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Left Side Transducer Legend: T1=3.5' Cable AN 01189 T3=Cable 2410 T2=Cable P05309 T4=Loop Sensor 7334-1 dBpT Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 40.431k 11.2 +0.0 +0.0 +0.1 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBpt dBpt dB +27.9 +0.0 39.2 53.8 -14.6 Polar Ant Magne 2 .059k 19.6 +0.0 +0.0 +0.0 +75.5 +0.0 95.1 110.5 -15.4 Magne 3 17.367k 6.7 +0.0 +0.0 +0.1 +30.4 +0.0 37.2 61.2 -24.0 Magne 4 48.199k -0.6 +0.0 +0.1 +0.1 +27.6 +0.0 27.2 52.3 -25.1 Magne 5 37.067k 1.0 +0.0 +0.0 +0.1 +28.1 +0.0 29.2 54.6 -25.4 Magne Page 44 of 161 Report No.: MIL05-043 6 19.449k 4.6 +0.0 +0.0 +0.1 +30.0 +0.0 34.7 60.2 -25.5 Magne 7 22.012k 3.7 +0.0 +0.0 +0.1 +29.6 +0.0 33.4 59.1 -25.7 Magne 8 34.264k 1.3 +0.0 +0.0 +0.1 +28.2 +0.0 29.6 55.3 -25.7 Magne 9 16.366k 5.1 +0.0 +0.0 +0.1 +30.7 +0.0 35.9 61.7 -25.8 Magne 10 12.802k 5.5 +0.1 -0.1 +0.1 +32.0 +0.0 37.6 63.8 -26.2 Magne 11 25.215k 2.5 +0.0 +0.0 +0.1 +29.1 +0.0 31.7 57.9 -26.2 Magne 12 11.400k 5.7 +0.1 -0.1 +0.1 +32.7 +0.0 38.5 64.8 -26.3 Magne 13 29.980k 1.5 +0.0 +0.0 +0.1 +28.5 +0.0 30.1 56.4 -26.3 Magne 14 35.426k 0.3 +0.0 +0.0 +0.1 +28.2 +0.0 28.6 55.0 -26.4 Magne 15 14.724k 4.7 +0.0 +0.0 +0.1 +31.1 +0.0 35.9 62.6 -26.7 Magne 16 37.988k -0.5 +0.0 +0.0 +0.1 +28.0 +0.0 27.6 54.4 -26.8 Magne 17 18.568k 3.4 +0.0 +0.0 +0.1 +30.2 +0.0 33.7 60.6 -26.9 Magne 18 45.116k -2.0 +0.0 +0.1 +0.1 +27.7 +0.0 25.9 52.9 -27.0 Magne 19 32.503k 0.2 +0.0 +0.0 +0.1 +28.3 +0.0 28.6 55.7 -27.1 Magne 20 43.194k -1.7 +0.0 +0.0 +0.1 +27.8 +0.0 26.2 53.3 -27.1 Magne 21 23.373k 1.7 +0.0 +0.0 +0.1 +29.4 +0.0 31.2 58.6 -27.4 Magne 22 33.424k -0.3 +0.0 +0.0 +0.1 +28.3 +0.0 28.1 55.5 -27.4 Magne 23 36.186k -0.8 +0.0 +0.0 +0.1 +28.1 +0.0 27.4 54.8 -27.4 Magne 24 27.177k 0.7 +0.0 +0.0 +0.1 +28.8 +0.0 29.6 57.3 -27.7 Magne 25 38.749k -1.6 +0.0 +0.0 +0.1 +28.0 +0.0 26.5 54.2 -27.7 Magne Page 45 of 161 Report No.: MIL05-043 26 49.200k -3.4 +0.0 +0.1 +0.1 +27.5 +0.0 24.3 52.1 -27.8 Magne 27 26.216k 0.6 +0.0 +0.0 +0.1 +29.0 +0.0 29.7 57.6 -27.9 Magne 28 23.814k 0.1 +0.0 +0.0 +0.1 +29.3 +0.0 29.5 58.4 -28.9 Magne 29 .110k 3.4 +0.0 +0.0 +0.0 +70.9 +0.0 74.3 105.2 -30.9 Magne 30 2.160k 1.9 +0.0 +0.0 +0.0 +45.8 +0.0 47.7 79.3 -31.6 Magne Page 46 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE101 Test Limit 82840 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function PC Monitor Keyboard Mouse VME Crate Power Supply Manufacturer Dell Dell Dell Dell by Microsoft Dawn AEMC Instruments Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/21/2005 2:10:44 PM 24 A. Brar Model # SIU Model # DHM MX-D9J367-47605-379-AYKJ 04N454 X06-08477 11-1011777-2119 AX502 S/N GLAT 2508 S/N JLJJ331 PC65341 TH-04N454-37171-33F-E488 none 002563 PC70344 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Front Side Transducer Legend: T1=3.5' Cable AN 01189 T3=Cable 2410 T2=Cable P05309 T4=Loop Sensor 7334-1 dBpT Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 40.591k 11.7 +0.0 +0.0 +0.1 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBpt dBpt dB +27.9 +0.0 39.7 53.8 -14.1 Polar Ant Magne 2 .055k 17.2 +0.0 +0.0 +0.0 +76.1 +0.0 93.3 111.2 -17.9 Magne 3 14.524k 6.6 +0.0 +0.0 +0.1 +31.2 +0.0 37.9 62.7 -24.8 Magne 4 47.639k -0.8 +0.0 +0.1 +0.1 +27.6 +0.0 27.0 52.4 -25.4 Magne 5 48.760k -0.9 +0.0 +0.1 +0.1 +27.5 +0.0 26.8 52.2 -25.4 Magne 6 21.972k 3.2 +0.0 +0.0 +0.1 +29.6 +0.0 32.9 59.1 -26.2 Magne Page 47 of 161 Report No.: MIL05-043 7 10.199k 5.7 +0.1 -0.1 +0.1 +33.4 +0.0 39.2 65.8 -26.6 Magne 8 29.780k 1.1 +0.0 +0.0 +0.1 +28.5 +0.0 29.7 56.5 -26.8 Magne 9 13.483k 4.4 +0.1 -0.1 +0.1 +31.7 +0.0 36.2 63.4 -27.2 Magne 10 17.407k 3.5 +0.0 +0.0 +0.1 +30.4 +0.0 34.0 61.2 -27.2 Magne 11 24.174k 1.4 +0.0 +0.0 +0.1 +29.2 +0.0 30.7 58.3 -27.6 Magne 12 25.535k 0.8 +0.0 +0.0 +0.1 +29.1 +0.0 30.0 57.8 -27.8 Magne 13 43.314k -2.6 +0.0 +0.0 +0.1 +27.8 +0.0 25.3 53.2 -27.9 Magne 14 .110k 5.9 +0.0 +0.0 +0.0 +70.9 +0.0 76.8 105.2 -28.4 Magne 15 33.744k -1.5 +0.0 +0.0 +0.1 +28.3 +0.0 26.9 55.4 -28.5 Magne 16 .181k 2.7 +0.0 +0.0 +0.0 +66.6 +0.0 69.3 100.8 -31.5 Magne 17 .299k 2.7 +0.0 +0.0 +0.0 +62.2 +0.0 64.9 96.5 -31.6 Magne 18 1.552k 1.7 +0.0 +0.0 +0.0 +48.6 +0.0 50.3 82.2 -31.9 Magne 19 2.337k 0.8 +0.0 +0.0 +0.0 +45.2 +0.0 46.0 78.6 -32.6 Magne 20 1.119k 1.0 +0.0 +0.0 +0.0 +51.3 +0.0 52.3 85.0 -32.7 Magne 21 2.921k 0.6 +0.0 +0.0 +0.0 +43.3 +0.0 43.9 76.7 -32.8 Magne 22 1.736k 0.3 +0.0 +0.0 +0.0 +47.7 +0.0 48.0 81.2 -33.2 Magne 23 3.258k 0.0 +0.0 +0.0 +0.0 +42.3 +0.0 42.3 75.7 -33.4 Magne 24 6.934k -0.2 +0.0 +0.0 +0.0 +35.9 +0.0 35.7 69.2 -33.5 Magne 25 4.243k -0.3 +0.0 +0.0 +0.0 +40.1 +0.0 39.8 73.4 -33.6 Magne 26 .220k 0.5 +0.0 +0.0 +0.0 +64.9 +0.0 65.4 99.1 -33.7 Magne 27 .330k 0.5 +0.0 +0.0 +0.0 +61.4 +0.0 61.9 95.6 -33.7 Magne Page 48 of 161 Report No.: MIL05-043 28 1.952k -0.4 +0.0 +0.0 +0.0 +46.7 +0.0 46.3 80.2 -33.9 Magne 29 3.458k -0.9 +0.0 +0.0 +0.0 +41.8 +0.0 40.9 75.2 -34.3 Magne 30 4.676k -1.5 +0.0 +0.0 +0.0 +39.2 +0.0 37.7 72.6 -34.9 Magne Page 49 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE101 Test Limit 82840 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function PC Monitor Keyboard Mouse VME Crate Power Supply Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer Dell Dell Dell Dell by Microsoft Dawn AEMC Instruments 10/21/2005 2:13:39 PM 25 A. Brar Model # SIU S/N GLAT 2508 Model # DHM MX-D9J367-47605-379-AYKJ 04N454 X06-08477 11-1011777-2119 AX502 S/N JLJJ331 PC65341 TH-04N454-37171-33F-E488 none 002563 PC70344 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Right Side Transducer Legend: T1=3.5' Cable AN 01189 T3=Cable 2410 T2=Cable P05309 T4=Loop Sensor 7334-1 dBpT Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 40.511k 10.4 +0.0 +0.0 +0.1 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBpt dBpt dB +27.9 +0.0 38.4 53.8 -15.4 Polar Ant Magne 2 .061k 17.5 +0.0 +0.0 +0.0 +75.3 +0.0 92.8 110.3 -17.5 Magne 3 .054k 17.5 +0.0 +0.0 +0.0 +76.3 +0.0 93.8 111.4 -17.6 Magne 4 44.836k 1.1 +0.0 +0.1 +0.1 +27.7 +0.0 29.0 52.9 -23.9 Magne 5 49.921k -0.4 +0.0 +0.1 +0.1 +27.5 +0.0 27.3 52.0 -24.7 Magne 6 12.642k 7.0 +0.1 -0.1 +0.1 +32.1 +0.0 39.2 64.0 -24.8 Magne Page 50 of 161 Report No.: MIL05-043 7 46.958k -0.6 +0.0 +0.1 +0.1 +27.6 +0.0 27.2 52.5 -25.3 Magne 8 34.264k 1.4 +0.0 +0.0 +0.1 +28.2 +0.0 29.7 55.3 -25.6 Magne 9 22.052k 3.6 +0.0 +0.0 +0.1 +29.6 +0.0 33.3 59.1 -25.8 Magne 10 48.800k -1.6 +0.0 +0.1 +0.1 +27.5 +0.0 26.1 52.2 -26.1 Magne 11 45.717k -1.4 +0.0 +0.1 +0.1 +27.7 +0.0 26.5 52.8 -26.3 Magne 12 20.410k 3.3 +0.0 +0.0 +0.1 +29.8 +0.0 33.2 59.8 -26.6 Magne 13 21.491k 2.9 +0.0 +0.0 +0.1 +29.6 +0.0 32.6 59.3 -26.7 Magne 14 11.441k 5.2 +0.1 -0.1 +0.1 +32.7 +0.0 38.0 64.8 -26.8 Magne 15 32.142k 0.4 +0.0 +0.0 +0.1 +28.4 +0.0 28.9 55.8 -26.9 Magne 16 17.287k 3.4 +0.0 +0.0 +0.1 +30.5 +0.0 34.0 61.2 -27.2 Magne 17 18.648k 2.6 +0.0 +0.0 +0.1 +30.2 +0.0 32.9 60.6 -27.7 Magne 18 26.456k 0.5 +0.0 +0.0 +0.1 +28.9 +0.0 29.5 57.5 -28.0 Magne 19 24.975k 0.6 +0.0 +0.0 +0.1 +29.1 +0.0 29.8 58.0 -28.2 Magne 20 .109k 5.5 +0.0 +0.0 +0.0 +71.0 +0.0 76.5 105.3 -28.8 Magne 21 1.079k 3.0 +0.0 +0.0 +0.0 +51.6 +0.0 54.6 85.3 -30.7 Magne 22 2.713k 2.4 +0.0 +0.0 +0.0 +43.9 +0.0 46.3 77.3 -31.0 Magne 23 .180k 2.8 +0.0 +0.0 +0.0 +66.6 +0.0 69.4 100.9 -31.5 Magne 24 .298k 2.5 +0.0 +0.0 +0.0 +62.3 +0.0 64.8 96.5 -31.7 Magne 25 1.375k 1.6 +0.0 +0.0 +0.0 +49.6 +0.0 51.2 83.2 -32.0 Magne 26 4.860k 1.3 +0.0 +0.0 +0.0 +38.9 +0.0 40.2 72.3 -32.1 Magne 27 3.114k 0.4 +0.0 +0.0 +0.0 +42.7 +0.0 43.1 76.1 -33.0 Magne Page 51 of 161 Report No.: MIL05-043 28 2.209k 0.3 +0.0 +0.0 +0.0 +45.7 +0.0 46.0 79.1 -33.1 Magne 29 4.523k 0.3 +0.0 +0.0 +0.0 +39.5 +0.0 39.8 72.9 -33.1 Magne 30 .218k 0.8 +0.0 +0.0 +0.0 +65.0 +0.0 65.8 99.2 -33.4 Magne Page 52 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE101 Test Limit 82840 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function PC Monitor Keyboard Mouse VME Crate Power Supply Manufacturer Dell Dell Dell Dell by Microsoft Dawn AEMC Instruments Manufacturer Stanford Linear Date: Time: Sequence#: Tested By: 10/21/2005 2:15:25 PM 26 A. Brar Model # SIU Model # DHM MX-D9J367-47605-379-AYKJ 04N454 X06-08477 11-1011777-2119 AX502 S/N GLAT 2508 S/N JLJJ331 PC65341 TH-04N454-37171-33F-E488 none 002563 PC70344 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Top Side Transducer Legend: T1=3.5' Cable AN 01189 T3=Cable 2410 T2=Cable P05309 T4=Loop Sensor 7334-1 dBpT Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 40.551k 11.2 +0.0 +0.0 +0.1 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBpt dBpt dB +27.9 +0.0 39.2 53.8 -14.6 Polar Ant Magne 2 .054k 19.9 +0.0 +0.0 +0.0 +76.2 +0.0 96.1 111.3 -15.2 Magne 3 46.037k -0.4 +0.0 +0.1 +0.1 +27.6 +0.0 27.4 52.7 -25.3 Magne 4 47.879k -1.4 +0.0 +0.1 +0.1 +27.6 +0.0 26.4 52.4 -26.0 Magne 5 26.136k 2.4 +0.0 +0.0 +0.1 +29.0 +0.0 31.5 57.6 -26.1 Magne 6 20.770k 3.5 +0.0 +0.0 +0.1 +29.8 +0.0 33.4 59.6 -26.2 Magne Page 53 of 161 Report No.: MIL05-043 7 12.602k 5.1 +0.1 -0.1 +0.1 +32.1 +0.0 37.3 64.0 -26.7 Magne 8 16.686k 4.0 +0.0 +0.0 +0.1 +30.6 +0.0 34.7 61.5 -26.8 Magne 9 18.728k 2.9 +0.0 +0.0 +0.1 +30.1 +0.0 33.1 60.5 -27.4 Magne 10 24.694k 1.1 +0.0 +0.0 +0.1 +29.2 +0.0 30.4 58.1 -27.7 Magne 11 30.460k -0.3 +0.0 +0.0 +0.1 +28.5 +0.0 28.3 56.3 -28.0 Magne 12 1.215k 3.9 +0.0 +0.0 +0.0 +50.6 +0.0 54.5 84.3 -29.8 Magne 13 .218k 3.9 +0.0 +0.0 +0.0 +65.0 +0.0 68.9 99.2 -30.3 Magne 14 1.103k 3.2 +0.0 +0.0 +0.0 +51.4 +0.0 54.6 85.1 -30.5 Magne 15 .110k 3.5 +0.0 +0.0 +0.0 +70.9 +0.0 74.4 105.2 -30.8 Magne 16 9.306k 0.3 +0.0 +0.0 +0.1 +33.9 +0.0 34.3 66.6 -32.3 Magne 17 1.648k 0.9 +0.0 +0.0 +0.0 +48.1 +0.0 49.0 81.7 -32.7 Magne 18 4.275k 0.7 +0.0 +0.0 +0.0 +40.0 +0.0 40.7 73.4 -32.7 Magne 19 2.289k 0.7 +0.0 +0.0 +0.0 +45.3 +0.0 46.0 78.8 -32.8 Magne 20 9.527k -0.3 +0.0 +0.0 +0.1 +33.8 +0.0 33.6 66.4 -32.8 Magne 21 2.537k 0.5 +0.0 +0.0 +0.0 +44.5 +0.0 45.0 77.9 -32.9 Magne 22 3.394k 0.4 +0.0 +0.0 +0.0 +42.0 +0.0 42.4 75.4 -33.0 Magne 23 3.738k 0.3 +0.0 +0.0 +0.0 +41.2 +0.0 41.5 74.5 -33.0 Magne 24 1.536k 0.4 +0.0 +0.0 +0.0 +48.7 +0.0 49.1 82.3 -33.2 Magne 25 .297k 0.9 +0.0 +0.0 +0.0 +62.3 +0.0 63.2 96.5 -33.3 Magne 26 .179k 0.8 +0.0 +0.0 +0.0 +66.7 +0.0 67.5 100.9 -33.4 Magne 27 2.008k -0.6 +0.0 +0.0 +0.0 +46.5 +0.0 45.9 79.9 -34.0 Magne Page 54 of 161 Report No.: MIL05-043 28 9.856k -2.1 +0.0 +0.0 +0.1 +33.6 +0.0 31.6 66.1 -34.5 Magne 29 3.130k -1.4 +0.0 +0.0 +0.0 +42.7 +0.0 41.3 76.1 -34.8 Magne 30 2.665k -2.0 +0.0 +0.0 +0.0 +44.1 +0.0 42.1 77.5 -35.4 Magne Page 55 of 161 Report No.: MIL05-043 RE102 - Radiated Emissions, Electric Field, 10kHz to 18GHz Test Equipment Function SA - E4446A Rod Antenna - 3301B Sig Gen - 2022D Cable Cable RG214/U Andrew Cable- CNT-195 Bicon Antenna EMCO3104 Horn - SAS 570 HF Pre AmpCable, 72" 2.92mm 40 GHz Horn Antenna 3115 HF Cable - PE35591-60 Asset # 02668 01579 00727 P05309 02410 01189 00732 02525 00785 P05317 02113 02716 S/N US44300408 92073275 119190-018 None None None 2683 155 part # 2490 3123A00283 None 9606-4660 None Cal Date 01/13/2005 01/12/2004 11/15/2004 08/01/2005 06/07/2004 04/12/2004 04/11/2005 06/10/2005 05/09/2005 07/12/2005 03/08/2005 08/09/2005 Cal Due 01/13/2007 01/12/2006 11/15/2006 08/01/2007 06/07/2006 04/12/2006 04/11/2007 06/10/2007 05/09/2007 07/12/2007 03/08/2007 08/09/2007 Test Procedure The signal generator was connected to the rod antenna through the calibration fixture. The test engineer injected a signal at 2MHz that was 6dB below the limit line and measured the resulting emission on the spectrum analyzer. The check was repeated at 15MHz and 30MHz. Then, the signal generator was removed and the antenna element was connected to the antenna and the antenna output was connected to the measurement system. The UUT was powered up in standard operating mode. The rod antenna was placed one meter in front of the UUT. The EMITest™ software automatically scanned from 10kHz to 30MHz using the sweep rates required by the Test Procedure. The biconical antenna was placed one meter in front of the UUT and was connected to the measurement system. The test engineer removed performed a path loss check at 200MHz. The EMITest™ software automatically scanned from 30MHz to 200MHz in horizontal and vertical antenna polarizations using the sweep rates required by the Test Procedure. The double ridge guide horn antenna was connected into the setup and placed one meter from the UUT setup. The test engineer performed a path loss check at 1GHz. The EMITest™ software automatically scanned from 200MHz to 1GHz in horizontal and vertical antenna polarizations using the sweep rates required by the Test Procedure. Then, the high frequency double ridge guide horn antenna was installed and placed one meter from the UUT setup. The antenna was then connected to the measurement system. The test engineer performed a path loss check at 18GHz. The EMITest™ software automatically scanned from 1GHz to 18GHz in horizontal and vertical antenna polarizations using the sweep rates required by the Test Procedure with the exception of 1.55 – 1.6 / Vertical, 1kHz RBW, where 1kHz RBW was used per Fred (Witness). Page 56 of 161 Report No.: MIL05-043 Rod Antenna, 10kHz - 30MHz Path Check Rod Antenna, 10kHz - 30MHz Test Setup Page 57 of 161 Report No.: MIL05-043 Bicon Antenna and Log Periodic Antenna Path Check Bicon Antenna, 30 - 200MHz Vertical Polarization Test Setup Page 58 of 161 Report No.: MIL05-043 Horn Antenna, 200 - 1000MHz Vertical Polarization Test Setup Horn Antenna, 200 - 1000MHz Vertical Polarization Closeup Page 59 of 161 Report No.: MIL05-043 RE102 Path Check for High Frequency Horn Antenna Horn Antenna, 8 - 18GHz Vertical Polarization Test Setup Page 60 of 161 Report No.: MIL05-043 RE102, 1 - 18GHz Solution for Sequence 19 Data Sheets Seq. # Test Description 0 Radiated Emissions 0 Radiated Emissions 0 Radiated Emissions 1 Radiated Emissions 3 Radiated Emissions 2 Radiated Emissions 0 Radiated Emissions 0 Radiated Emissions 5 Radiated Emissions 4 Radiated Emissions 11 Radiated Emissions 6 Radiated Emissions 15 Radiated Emissions 19 Radiated Emissions 12 Radiated Emissions 7 Radiated Emissions 14 Radiated Emissions 10 Radiated Emissions 0 Radiated Emissions 13 Radiated Emissions 8 Radiated Emissions Frequency / Polarity 10kHz Path Check 15MHz Path Check 30MHz Path Check 10kHz – 30MHz / Vertical 30 – 200MHz / Horizontal 30 – 200MHz / Vertical 200MHz Path Check 1000MHz Path Check 200 – 1000MHz / Horizontal 200 – 1000MHz / Vertical 1 – 1.55GHz / Horizontal 1 – 1.55GHz / Vertical 1.55 – 1.6 / Horizontal 1.55 – 1.6 / Vertical, 1kHz RBW 1.6 – 1.77GHz / Horizontal 1.6 – 1.77GHz / Vertical 1.77 – 2.3GHz / Horizontal 1.77 – 2.3GHz / Vertical 18GHz Path Check 2.3 – 18GHz / Horizontal 2.3 – 18GHz / Vertical Page 61 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 82840 Radiated Scan Date: Time: Sequence#: Tested By: 10/19/2005 1:06:22 PM 0 A. Brar Equipment Under Test (* = EUT): Function Manufacturer Model # S/N Support Devices: Function Model # S/N Manufacturer Test Conditions / Notes: Path Check Sweep. Signal at 10KHz. 90 (spec limit) - 6dB - 4.2 (Antenna Factor) = 79.8dBuV signal level. Transducer Legend: T1=AN 01579 Rod Antenna T3=Cable P05309 T2=3.5' Cable AN 01189 T4=Cable 2410 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 10.000k 80.8 +4.2 +0.1 -0.1 Test Distance: None T4 Dist Corr Spec dB Table dBµV/m dBµV/m +0.1 +0.0 85.1 90.0 Margin dB -4.9 Polar Ant None 2 91.877k 25.9 +4.0 +0.0 +0.0 +0.1 +0.0 30.0 90.0 -60.0 None 3 28.388k 25.0 +4.0 +0.0 +0.0 +0.1 +0.0 29.1 90.0 -60.9 None 4 30.938k 22.3 +4.0 +0.0 +0.0 +0.1 +0.0 26.4 90.0 -63.6 None 5 51.475k 22.1 +4.0 +0.0 +0.1 +0.1 +0.0 26.3 90.0 -63.7 None 6 36.576k 21.7 +4.0 +0.0 +0.0 +0.1 +0.0 25.8 90.0 -64.2 None 7 54.025k 21.5 +4.0 +0.0 +0.1 +0.1 +0.0 25.7 90.0 -64.3 None 8 41.408k 21.5 +4.0 +0.0 +0.0 +0.1 +0.0 25.6 90.0 -64.4 None 9 43.556k 21.0 +4.0 +0.0 +0.0 +0.1 +0.0 25.1 90.0 -64.9 None 10 48.925k 20.9 +4.0 +0.0 +0.1 +0.1 +0.0 25.1 90.0 -64.9 None Page 62 of 161 Report No.: MIL05-043 11 40.603k 20.7 +4.0 +0.0 +0.0 +0.1 +0.0 24.8 90.0 -65.2 None 12 46.374k 20.6 +4.0 +0.0 +0.1 +0.1 +0.0 24.8 90.0 -65.2 None 13 56.710k 20.8 +4.0 +0.0 +0.0 +0.0 +0.0 24.8 90.0 -65.2 None 14 58.455k 20.7 +4.0 +0.0 +0.0 +0.0 +0.0 24.7 90.0 -65.3 None 15 49.730k 20.3 +4.0 +0.0 +0.1 +0.1 +0.0 24.5 90.0 -65.5 None 16 60.468k 20.4 +4.0 +0.0 +0.0 +0.0 +0.0 24.4 90.0 -65.6 None 17 69.058k 19.8 +4.0 +0.0 +0.0 +0.1 +0.0 23.9 90.0 -66.1 None 18 225.849k 19.8 +4.0 +0.0 +0.0 +0.0 +0.0 23.8 90.0 -66.2 None 19 55.904k 19.7 +4.0 +0.0 +0.0 +0.0 +0.0 23.7 90.0 -66.3 None 20 59.528k 19.6 +4.0 +0.0 +0.0 +0.0 +0.0 23.6 90.0 -66.4 None 21 66.508k 19.2 +4.0 +0.0 +0.0 +0.1 +0.0 23.3 90.0 -66.7 None 22 54.294k 19.0 +4.0 +0.0 +0.1 +0.1 +0.0 23.2 90.0 -66.8 None 23 429.349k 18.6 +4.1 +0.0 +0.1 +0.0 +0.0 22.8 90.0 -67.2 None 24 67.314k 18.5 +4.0 +0.0 +0.0 +0.1 +0.0 22.6 90.0 -67.4 None 25 70.266k 18.5 +4.0 +0.0 +0.0 +0.1 +0.0 22.6 90.0 -67.4 None 26 77.917k 18.3 +4.1 +0.0 +0.0 +0.0 +0.0 22.4 90.0 -67.6 None 27 110.266k 18.4 +4.0 +0.0 +0.0 +0.0 +0.0 22.4 90.0 -67.6 None Page 63 of 161 Report No.: MIL05-043 28 79.394k 18.2 +4.1 +0.0 +0.0 +0.0 +0.0 22.3 90.0 -67.7 None 29 305.399k 18.3 +3.9 +0.0 +0.1 +0.0 +0.0 22.3 90.0 -67.7 None 30 101.004k 17.9 +4.0 +0.0 +0.0 +0.0 +0.0 21.9 90.0 -68.1 None Page 64 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 82840 Radiated Scan Date: Time: Sequence#: Tested By: 10/19/2005 1:19:28 PM 0 A. Brar Equipment Under Test (* = EUT): Function Manufacturer Model # S/N Support Devices: Function Model # S/N Manufacturer Test Conditions / Notes: Path Check Sweep. Signal at 15.005MHz. 90 (spec limit) - 6dB - 6.9 (Antenna Factor) = 77.1dBuV signal level. Transducer Legend: T1=AN 01579 Rod Antenna T3=Cable P05309 T2=3.5' Cable AN 01189 T4=Cable 2410 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 15.005M 78.0 +6.9 +0.1 +0.2 Test Distance: None T4 Dist Corr Spec dB Table dBµV/m dBµV/m +0.2 +0.0 85.4 90.0 Margin dB -4.6 Polar Ant None 2 10.536k 23.2 +4.2 +0.1 -0.1 +0.1 +0.0 27.5 90.0 -62.5 None 3 11.341k 21.7 +4.2 +0.1 -0.1 +0.1 +0.0 26.0 90.0 -64.0 None 4 12.549k 21.4 +4.1 +0.1 -0.1 +0.1 +0.0 25.6 90.0 -64.4 None 5 13.086k 21.1 +4.1 +0.1 -0.1 +0.1 +0.0 25.3 90.0 -64.7 None 6 13.892k 20.4 +4.1 +0.1 -0.1 +0.1 +0.0 24.6 90.0 -65.4 None 7 14.294k 20.2 +4.1 +0.0 +0.0 +0.1 +0.0 24.4 90.0 -65.6 None 8 16.710k 19.2 +4.1 +0.0 +0.0 +0.1 +0.0 23.4 90.0 -66.6 None 9 149.999k 19.3 +4.0 +0.0 +0.0 +0.0 +0.0 23.3 90.0 -66.7 None 10 179.599k 18.9 +4.0 +0.0 +0.0 +0.0 +0.0 22.9 90.0 -67.1 None Page 65 of 161 Report No.: MIL05-043 11 17.247k 18.7 +4.0 +0.0 +0.0 +0.1 +0.0 22.8 90.0 -67.2 None 12 166.649k 18.7 +4.0 +0.0 +0.0 +0.0 +0.0 22.7 90.0 -67.3 None 13 153.699k 18.5 +4.0 +0.0 +0.0 +0.0 +0.0 22.5 90.0 -67.5 None 14 41.005k 18.1 +4.0 +0.0 +0.0 +0.1 +0.0 22.2 90.0 -67.8 None 15 172.199k 18.0 +4.0 +0.0 +0.0 +0.0 +0.0 22.0 90.0 -68.0 None 16 211.049k 17.9 +4.0 +0.0 +0.0 +0.0 +0.0 21.9 90.0 -68.1 None 17 22.079k 17.6 +4.0 +0.0 +0.0 +0.1 +0.0 21.7 90.0 -68.3 None 18 19.395k 17.4 +4.0 +0.0 +0.0 +0.1 +0.0 21.5 90.0 -68.5 None 19 220.299k 16.9 +4.0 +0.0 +0.0 +0.0 +0.0 20.9 90.0 -69.1 None 20 216.599k 16.5 +4.0 +0.0 +0.0 +0.0 +0.0 20.5 90.0 -69.5 None 21 1.168M 15.8 +4.2 +0.0 +0.0 +0.1 +0.0 20.1 90.0 -69.9 None 22 24.227k 15.9 +4.0 +0.0 +0.0 +0.1 +0.0 20.0 90.0 -70.0 None 23 23.690k 15.7 +4.0 +0.0 +0.0 +0.1 +0.0 19.8 90.0 -70.2 None 24 29.793M 7.9 +10.8 +0.1 +0.1 +0.3 +0.0 19.2 90.0 -70.8 None 25 29.864k 14.9 +4.0 +0.0 +0.0 +0.1 +0.0 19.0 90.0 -71.0 None 26 25.972k 14.8 +4.0 +0.0 +0.0 +0.1 +0.0 18.9 90.0 -71.1 None 27 26.784M 8.2 +10.0 +0.2 +0.2 +0.3 +0.0 18.9 90.0 -71.1 None Page 66 of 161 Report No.: MIL05-043 28 27.985k 14.7 +4.0 +0.0 +0.0 +0.1 +0.0 18.8 90.0 -71.2 None 29 29.673M 7.5 +10.8 +0.1 +0.1 +0.3 +0.0 18.8 90.0 -71.2 None 30 29.880M 7.2 +10.9 +0.1 +0.1 +0.3 +0.0 18.6 90.0 -71.4 None Page 67 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 82840 Radiated Scan Date: Time: Sequence#: Tested By: 10/19/2005 1:25:18 PM 0 A. Brar Equipment Under Test (* = EUT): Function Manufacturer Model # S/N Support Devices: Function Model # S/N Manufacturer Test Conditions / Notes: Path Check Sweep. Signal at 30.00MHz. 90 (spec limit) - 6dB - 10.9 (Antenna Factor) = 73.1dBuV signal level. Transducer Legend: T1=AN 01579 Rod Antenna T3=Cable P05309 T2=3.5' Cable AN 01189 T4=Cable 2410 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 30.000M 70.7 +10.9 +0.1 +0.1 Test Distance: None T4 Dist Corr Spec dB Table dBµV/m dBµV/m +0.3 +0.0 82.1 90.0 Margin dB -7.9 Polar Ant None 2 10.133k 25.6 +4.2 +0.1 -0.1 +0.1 +0.0 29.9 90.0 -60.1 None 3 11.744k 25.0 +4.2 +0.1 -0.1 +0.1 +0.0 29.3 90.0 -60.7 None 4 15.234k 23.0 +4.1 +0.0 +0.0 +0.1 +0.0 27.2 90.0 -62.8 None 5 15.771k 22.2 +4.1 +0.0 +0.0 +0.1 +0.0 26.4 90.0 -63.6 None 6 29.697M 14.8 +10.8 +0.1 +0.1 +0.3 +0.0 26.1 90.0 -63.9 None 7 14.294k 20.6 +4.1 +0.0 +0.0 +0.1 +0.0 24.8 90.0 -65.2 None 8 153.699k 19.9 +4.0 +0.0 +0.0 +0.0 +0.0 23.9 90.0 -66.1 None 9 14.026k 19.3 +4.1 +0.1 -0.1 +0.1 +0.0 23.5 90.0 -66.5 None 10 14.831k 19.3 +4.1 +0.0 +0.0 +0.1 +0.0 23.5 90.0 -66.5 None Page 68 of 161 Report No.: MIL05-043 11 40.737k 19.0 +4.0 +0.0 +0.0 +0.1 +0.0 23.1 90.0 -66.9 None 12 16.173k 18.7 +4.1 +0.0 +0.0 +0.1 +0.0 22.9 90.0 -67.1 None 13 179.599k 16.7 +4.0 +0.0 +0.0 +0.0 +0.0 20.7 90.0 -69.3 None 14 185.149k 16.7 +4.0 +0.0 +0.0 +0.0 +0.0 20.7 90.0 -69.3 None 15 201.799k 16.7 +4.0 +0.0 +0.0 +0.0 +0.0 20.7 90.0 -69.3 None 16 29.462k 16.2 +4.0 +0.0 +0.0 +0.1 +0.0 20.3 90.0 -69.7 None 17 22.616k 16.0 +4.0 +0.0 +0.0 +0.1 +0.0 20.1 90.0 -69.9 None 18 29.601M 8.5 +10.8 +0.1 +0.1 +0.3 +0.0 19.8 90.0 -70.2 None 19 23.422k 15.4 +4.0 +0.0 +0.0 +0.1 +0.0 19.5 90.0 -70.5 None 20 23.824k 15.3 +4.0 +0.0 +0.0 +0.1 +0.0 19.4 90.0 -70.6 None 21 22.722M 9.5 +8.9 +0.2 +0.2 +0.3 +0.0 19.1 90.0 -70.9 None 22 29.505M 7.8 +10.8 +0.1 +0.1 +0.3 +0.0 19.1 90.0 -70.9 None 23 24.262M 8.8 +9.3 +0.2 +0.2 +0.3 +0.0 18.8 90.0 -71.2 None 24 33.086k 14.6 +4.0 +0.0 +0.0 +0.1 +0.0 18.7 90.0 -71.3 None 25 28.580M 7.7 +10.5 +0.1 +0.1 +0.3 +0.0 18.7 90.0 -71.3 None 26 1.160M 14.3 +4.2 +0.0 +0.0 +0.1 +0.0 18.6 90.0 -71.4 None 27 28.412M 7.7 +10.4 +0.1 +0.1 +0.3 +0.0 18.6 90.0 -71.4 None Page 69 of 161 Report No.: MIL05-043 28 27.391M 7.8 +10.2 +0.1 +0.1 +0.3 +0.0 18.5 90.0 -71.5 None 29 36.039k 14.3 +4.0 +0.0 +0.0 +0.1 +0.0 18.4 90.0 -71.6 None 30 366.449k 14.3 +4.0 +0.0 +0.1 +0.0 +0.0 18.4 90.0 -71.6 None Page 70 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/19/2005 1:56:49 PM 1 A. Brar Model # SIU S/N GLAT 2508 Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=AN 01579 Rod Antenna T3=Cable P05309 T2=3.5' Cable AN 01189 T4=Cable 2410 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 23.233M 28.3 +9.0 +0.2 +0.2 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +0.3 +0.0 38.0 90.0 -52.0 Polar Ant Rod A 2 14.022M 29.0 +6.6 +0.1 +0.2 +0.2 +0.0 36.1 90.0 -53.9 Rod A 3 17.976M 25.9 +7.7 +0.1 +0.1 +0.3 +0.0 34.1 90.0 -55.9 Rod A 4 13.972M 26.8 +6.6 +0.1 +0.2 +0.2 +0.0 33.9 90.0 -56.1 Rod A 5 18.026M 25.6 +7.7 +0.1 +0.1 +0.3 +0.0 33.8 90.0 -56.2 Rod A 6 19.978M 24.8 +8.1 +0.1 +0.1 +0.3 +0.0 33.4 90.0 -56.6 Rod A Page 71 of 161 Report No.: MIL05-043 7 10.670k 28.6 +4.2 +0.1 -0.1 +0.1 +0.0 32.9 90.0 -57.1 Rod A 8 20.028M 24.1 +8.1 +0.1 +0.1 +0.3 +0.0 32.7 90.0 -57.3 Rod A 9 23.991M 22.6 +9.2 +0.2 +0.2 +0.3 +0.0 32.5 90.0 -57.5 Rod A 10 22.994M 22.6 +9.0 +0.2 +0.2 +0.3 +0.0 32.3 90.0 -57.7 Rod A 11 24.023M 22.2 +9.2 +0.2 +0.2 +0.3 +0.0 32.1 90.0 -57.9 Rod A 12 15.974M 23.9 +7.2 +0.1 +0.2 +0.2 +0.0 31.6 90.0 -58.4 Rod A 13 19.998M 22.7 +8.1 +0.1 +0.1 +0.3 +0.0 31.3 90.0 -58.7 Rod A 14 16.024M 23.4 +7.2 +0.1 +0.2 +0.2 +0.0 31.1 90.0 -58.9 Rod A 15 12.549k 26.5 +4.1 +0.1 -0.1 +0.1 +0.0 30.7 90.0 -59.3 Rod A 16 17.175M 22.7 +7.5 +0.1 +0.2 +0.2 +0.0 30.7 90.0 -59.3 Rod A 17 13.892k 26.2 +4.1 +0.1 -0.1 +0.1 +0.0 30.4 90.0 -59.6 Rod A 18 1.168M 26.1 +4.2 +0.0 +0.0 +0.1 +0.0 30.4 90.0 -59.6 Rod A 19 15.544M 22.8 +7.1 +0.1 +0.2 +0.2 +0.0 30.4 90.0 -59.6 Rod A 20 1.587M 25.4 +4.3 +0.1 +0.0 +0.1 +0.0 29.9 90.0 -60.1 Rod A 21 15.203M 22.2 +7.0 +0.1 +0.2 +0.2 +0.0 29.7 90.0 -60.3 Rod A 22 16.965M 21.6 +7.4 +0.1 +0.2 +0.2 +0.0 29.5 90.0 -60.5 Rod A 23 18.176M 21.2 +7.7 +0.1 +0.1 +0.3 +0.0 29.4 90.0 -60.6 Rod A 24 15.771k 25.0 +4.1 +0.0 +0.0 +0.1 +0.0 29.2 90.0 -60.8 Rod A 25 816.000k 25.2 +4.0 +0.0 +0.0 +0.0 +0.0 29.2 90.0 -60.8 Rod A 26 16.174M 21.4 +7.2 +0.1 +0.2 +0.2 +0.0 29.1 90.0 -60.9 Rod A 27 1.519M 24.4 +4.3 +0.1 +0.0 +0.1 +0.0 28.9 90.0 -61.1 Rod A Page 72 of 161 Report No.: MIL05-043 28 1.351M 24.5 +4.2 +0.0 +0.0 +0.1 +0.0 28.8 90.0 -61.2 Rod A 29 21.980M 19.6 +8.7 +0.1 +0.1 +0.3 +0.0 28.8 90.0 -61.2 Rod A 30 24.997M 18.5 +9.5 +0.2 +0.2 +0.3 +0.0 28.7 90.0 -61.3 Rod A Page 73 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/19/2005 2:42:38 PM 3 A. Brar Model # SIU S/N GLAT 2508 Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=8447D OPT 010 AN00686 SN 2944A08591 T3=Cable P05309 T5=Bicon AN732 4-11-05 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 T5 MHz dBµV dB dB dB 1 95.994M 51.0 -29.2 +0.2 +0.2 +13.4 2 132.019M 49.6 -29.1 +0.2 +0.3 +12.7 3 133.342M 49.1 -29.1 +0.2 +0.3 +12.7 4 199.976M 43.5 -28.8 +0.2 +0.3 +15.8 5 98.999M 46.4 -29.3 +0.2 +0.2 +12.3 T2=3.5' Cable AN 01189 T4=Cable 2410 T4 Test Distance: 1 Meter Dist Corr Spec Margin dB Table dBµV/m dBµV/m +0.7 +0.0 36.3 90.0 Polar dB -53.7 Ant Horiz +0.8 +0.0 34.5 90.0 -55.5 Horiz +0.8 +0.0 34.0 90.0 -56.0 Horiz +1.0 +0.0 32.0 90.0 -58.0 Horiz +0.8 +0.0 30.6 90.0 -59.4 Horiz Page 74 of 161 Report No.: MIL05-043 6 192.018M 36.9 7 59.987M 42.8 8 181.504M 35.6 9 113.143M 40.0 10 134.313M 39.3 11 87.025M 39.0 12 88.027M 37.8 13 94.993M 37.8 14 178.857M 33.7 15 179.916M 33.0 16 140.046M 37.0 17 88.462M 35.5 18 135.989M 36.6 19 111.996M 36.7 20 140.399M 35.8 21 176.035M 31.5 22 178.152M 31.2 23 197.972M 31.6 24 178.416M 30.9 25 66.692M 39.5 26 120.023M 34.8 27 144.015M 34.5 -28.9 +16.0 -29.3 +10.7 -28.9 +16.3 -29.2 +12.3 -29.1 +12.8 -29.3 +12.9 -29.3 +13.8 -29.2 +13.7 -28.9 +16.4 -28.9 +16.4 -29.1 +12.8 -29.3 +14.2 -29.1 +12.8 -29.2 +12.3 -29.1 +12.9 -28.9 +16.5 -28.9 +16.4 -28.8 +15.9 -28.9 +16.4 -29.3 +8.7 -29.1 +12.5 -29.1 +12.9 +0.2 +0.3 +1.1 +0.0 25.6 90.0 -64.4 Horiz +0.1 +0.2 +0.5 +0.0 25.0 90.0 -65.0 Horiz +0.3 +0.3 +1.0 +0.0 24.6 90.0 -65.4 Horiz +0.2 +0.3 +0.7 +0.0 24.3 90.0 -65.7 Horiz +0.2 +0.3 +0.8 +0.0 24.3 90.0 -65.7 Horiz +0.2 +0.2 +0.6 +0.0 23.6 90.0 -66.4 Horiz +0.2 +0.2 +0.7 +0.0 23.4 90.0 -66.6 Horiz +0.2 +0.2 +0.7 +0.0 23.4 90.0 -66.6 Horiz +0.3 +0.3 +1.0 +0.0 22.8 90.0 -67.2 Horiz +0.3 +0.3 +1.0 +0.0 22.1 90.0 -67.9 Horiz +0.2 +0.2 +0.8 +0.0 21.9 90.0 -68.1 Horiz +0.2 +0.2 +0.7 +0.0 21.5 90.0 -68.5 Horiz +0.2 +0.2 +0.8 +0.0 21.5 90.0 -68.5 Horiz +0.2 +0.3 +0.7 +0.0 21.0 90.0 -69.0 Horiz +0.2 +0.2 +0.8 +0.0 20.8 90.0 -69.2 Horiz +0.3 +0.3 +1.0 +0.0 20.7 90.0 -69.3 Horiz +0.3 +0.3 +1.0 +0.0 20.3 90.0 -69.7 Horiz +0.2 +0.3 +1.0 +0.0 20.2 90.0 -69.8 Horiz +0.3 +0.3 +1.0 +0.0 20.0 90.0 -70.0 Horiz +0.2 +0.2 +0.5 +0.0 19.8 90.0 -70.2 Horiz +0.2 +0.3 +0.8 +0.0 19.5 90.0 -70.5 Horiz +0.2 +0.2 +0.8 +0.0 19.5 90.0 -70.5 Horiz Page 75 of 161 Report No.: MIL05-043 28 140.575M 34.2 29 105.998M 34.9 30 160.069M 32.0 -29.1 +12.9 -29.2 +12.2 -29.0 +14.5 +0.2 +0.2 +0.8 +0.0 19.2 90.0 -70.8 Horiz +0.2 +0.3 +0.7 +0.0 19.1 90.0 -70.9 Horiz +0.2 +0.3 +0.8 +0.0 18.8 90.0 -71.2 Horiz Page 76 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Manufacturer Power Supply AEMC Instruments VME Crate Dawn Mouse Dell by Microsoft Keyboard Dell Monitor Dell PC Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/19/2005 2:38:59 PM 2 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=8447D OPT 010 AN00686 SN 2944A08591 T3=Cable P05309 T5=Bicon AN732 4-11-05 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 T5 MHz dBµV dB dB dB 1 95.994M 50.0 -29.2 +0.2 +0.2 +13.4 2 98.999M 50.0 -29.3 +0.2 +0.2 +12.3 3 132.019M 46.9 -29.1 +0.2 +0.3 +12.7 4 40.028M 48.4 -29.4 +0.2 +0.2 +10.6 5 199.976M 41.2 -28.8 +0.2 +0.3 +15.8 T2=3.5' Cable AN 01189 T4=Cable 2410 T4 Test Distance: 1 Meter Dist Corr Spec Margin dB Table dBµV/m dBµV/m +0.7 +0.0 35.3 90.0 Polar dB -54.7 Ant Vert +0.8 +0.0 34.2 90.0 -55.8 Vert +0.8 +0.0 31.8 90.0 -58.2 Vert +0.5 +0.0 30.5 90.0 -59.5 Vert +1.0 +0.0 29.7 90.0 -60.3 Vert Page 77 of 161 Report No.: MIL05-043 6 32.990M 45.6 7 41.457M 45.9 8 40.399M 45.9 9 36.059M 43.4 10 159.981M 38.9 11 181.504M 36.7 12 180.004M 36.3 13 144.015M 39.8 14 120.023M 39.5 15 191.995M 34.4 16 177.799M 33.4 17 181.768M 33.3 18 178.857M 32.7 19 34.048M 38.1 20 60.030M 39.0 21 95.515M 35.5 22 178.240M 31.8 23 100.000M 36.8 24 175.946M 31.2 25 94.949M 34.7 26 114.025M 35.7 -29.4 +12.2 -29.4 +10.7 -29.4 +10.6 -29.4 +11.3 -29.0 +14.5 -28.9 +16.3 -28.9 +16.4 -29.1 +12.9 -29.1 +12.5 -28.9 +16.0 -28.9 +16.4 -28.9 +16.3 -28.9 +16.4 -29.4 +11.8 -29.3 +10.7 -29.2 +13.5 -28.9 +16.4 -29.3 +12.0 -28.9 +16.5 -29.2 +13.7 -29.2 +12.4 +0.2 +0.1 +0.4 +0.0 29.1 90.0 -60.9 Vert +0.2 +0.2 +0.5 +0.0 28.1 90.0 -61.9 Vert +0.2 +0.2 +0.5 +0.0 28.0 90.0 -62.0 Vert +0.3 +0.1 +0.4 +0.0 26.1 90.0 -63.9 Vert +0.2 +0.3 +0.8 +0.0 25.7 90.0 -64.3 Vert +0.3 +0.3 +1.0 +0.0 25.7 90.0 -64.3 Vert +0.3 +0.3 +1.0 +0.0 25.4 90.0 -64.6 Vert +0.2 +0.2 +0.8 +0.0 24.8 90.0 -65.2 Vert +0.2 +0.3 +0.8 +0.0 24.2 90.0 -65.8 Vert +0.2 +0.3 +1.1 +0.0 23.1 90.0 -66.9 Vert +0.3 +0.3 +1.0 +0.0 22.5 90.0 -67.5 Vert +0.3 +0.3 +1.0 +0.0 22.3 90.0 -67.7 Vert +0.3 +0.3 +1.0 +0.0 21.8 90.0 -68.2 Vert +0.3 +0.1 +0.4 +0.0 21.3 90.0 -68.7 Vert +0.1 +0.2 +0.5 +0.0 21.2 90.0 -68.8 Vert +0.2 +0.2 +0.7 +0.0 20.9 90.0 -69.1 Vert +0.3 +0.3 +1.0 +0.0 20.9 90.0 -69.1 Vert +0.2 +0.2 +0.8 +0.0 20.7 90.0 -69.3 Vert +0.3 +0.3 +1.0 +0.0 20.4 90.0 -69.6 Vert +0.2 +0.2 +0.7 +0.0 20.3 90.0 -69.7 Vert +0.2 +0.3 +0.7 +0.0 20.1 90.0 -69.9 Vert Page 78 of 161 Report No.: MIL05-043 27 99.956M 36.0 28 177.181M 30.8 29 140.487M 34.6 30 133.254M 34.4 -29.3 +12.0 -28.9 +16.4 -29.1 +12.9 -29.1 +12.7 +0.2 +0.2 +0.8 +0.0 19.9 90.0 -70.1 Vert +0.3 +0.3 +1.0 +0.0 19.9 90.0 -70.1 Vert +0.2 +0.2 +0.8 +0.0 19.6 90.0 -70.4 Vert +0.2 +0.3 +0.8 +0.0 19.3 90.0 -70.7 Vert Page 79 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 82840 Radiated Scan Date: Time: Sequence#: Tested By: 10/19/2005 1:37:48 PM 0 A. Brar Equipment Under Test (* = EUT): Function Manufacturer Model # S/N Support Devices: Function Model # S/N Manufacturer Test Conditions / Notes: Path Check Sweep. Signal at 200.00MHz. 90 (spec limit) - 6dB - 15.8 (Antenna Factor) = 68.2dBuV signal level. Transducer Legend: T1=8447D OPT 010 AN00686 SN 2944A08591 T3=Cable P05309 T5=Bicon AN732 4-11-05 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 T5 MHz dBµV dB dB dB 1 199.976M 94.8 -28.8 +0.2 +0.3 +15.8 2 199.670M 31.0 -28.8 +0.2 +0.3 +15.8 3 188.210M 28.9 -28.9 +0.2 +0.3 +16.1 4 186.002M 28.5 -28.9 +0.3 +0.3 +16.2 5 189.354M 28.7 -28.9 +0.2 +0.3 +16.1 6 188.207M 28.6 -28.9 +0.2 +0.3 +16.1 7 188.208M 28.4 -28.9 +0.2 +0.3 +16.1 8 188.210M 28.4 -28.9 +0.2 +0.3 +16.1 9 193.209M 28.4 -28.9 +0.2 +0.3 +16.0 T2=3.5' Cable AN 01189 T4=Cable 2410 T4 Test Distance: None Dist Corr Spec dB Table dBµV/m dBµV/m +1.0 +0.0 83.3 90.0 Margin Polar dB -6.7 Ant None +1.0 +0.0 19.5 90.0 -70.5 None +1.1 +0.0 17.7 90.0 -72.3 None +1.1 +0.0 17.5 90.0 -72.5 None +1.1 +0.0 17.5 90.0 -72.5 None +1.1 +0.0 17.4 90.0 -72.6 None +1.1 +0.0 17.2 90.0 -72.8 None +1.1 +0.0 17.2 90.0 -72.8 None +1.1 +0.0 17.1 90.0 -72.9 None Page 80 of 161 Report No.: MIL05-043 10 178.945M 27.9 11 188.208M 28.2 12 199.446M 28.5 13 181.151M 27.9 14 189.566M 28.1 15 189.707M 28.1 16 190.096M 28.1 17 190.427M 28.1 18 199.552M 28.4 19 188.210M 27.9 20 183.356M 27.6 21 191.841M 27.9 22 188.207M 27.6 23 188.210M 27.6 24 189.672M 27.6 25 188.207M 27.5 26 193.834M 27.6 27 190.745M 27.5 -28.9 +16.4 -28.9 +16.1 -28.8 +15.8 -28.9 +16.3 -28.9 +16.1 -28.9 +16.1 -28.9 +16.1 -28.9 +16.1 -28.8 +15.8 -28.9 +16.1 -28.9 +16.3 -28.9 +16.0 -28.9 +16.1 -28.9 +16.1 -28.9 +16.1 -28.9 +16.1 -28.9 +16.0 -28.9 +16.0 +0.3 +0.3 +1.0 +0.0 17.0 90.0 -73.0 None +0.2 +0.3 +1.1 +0.0 17.0 90.0 -73.0 None +0.2 +0.3 +1.0 +0.0 17.0 90.0 -73.0 None +0.3 +0.3 +1.0 +0.0 16.9 90.0 -73.1 None +0.2 +0.3 +1.1 +0.0 16.9 90.0 -73.1 None +0.2 +0.3 +1.1 +0.0 16.9 90.0 -73.1 None +0.2 +0.3 +1.1 +0.0 16.9 90.0 -73.1 None +0.2 +0.3 +1.1 +0.0 16.9 90.0 -73.1 None +0.2 +0.3 +1.0 +0.0 16.9 90.0 -73.1 None +0.2 +0.3 +1.1 +0.0 16.7 90.0 -73.3 None +0.3 +0.3 +1.0 +0.0 16.6 90.0 -73.4 None +0.2 +0.3 +1.1 +0.0 16.6 90.0 -73.4 None +0.2 +0.3 +1.1 +0.0 16.4 90.0 -73.6 None +0.2 +0.3 +1.1 +0.0 16.4 90.0 -73.6 None +0.2 +0.3 +1.1 +0.0 16.4 90.0 -73.6 None +0.2 +0.3 +1.1 +0.0 16.3 90.0 -73.7 None +0.2 +0.3 +1.1 +0.0 16.3 90.0 -73.7 None +0.2 +0.3 +1.1 +0.0 16.2 90.0 -73.8 None Page 81 of 161 Report No.: MIL05-043 28 193.268M 27.5 29 194.023M 27.5 30 198.573M 27.7 -28.9 +16.0 -28.9 +16.0 -28.8 +15.8 +0.2 +0.3 +1.1 +0.0 16.2 90.0 -73.8 None +0.2 +0.3 +1.1 +0.0 16.2 90.0 -73.8 None +0.2 +0.3 +1.0 +0.0 16.2 90.0 -73.8 None Page 82 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 82840 Radiated Scan Date: Time: Sequence#: Tested By: 10/19/2005 1:42:31 PM 0 A. Brar Equipment Under Test (* = EUT): Function Manufacturer Model # S/N Support Devices: Function Model # S/N Manufacturer Test Conditions / Notes: Path Check Sweep. Signal at 1000.00MHz. 90 (spec limit) - 6dB - 22.7 (Antenna Factor) = 61.3dBuV signal level. Transducer Legend: T1=8447D OPT 010 AN00686 SN 2944A08591 T3=Cable P05309 T5=SAS-570 Horn Antenna - 2525 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 T5 MHz dBµV dB dB dB 1 1000.000M 86.0 -29.1 +0.5 +0.8 +22.8 2 499.900M 54.9 -29.7 +0.4 +0.5 +16.5 3 292.599M 28.3 -28.4 +0.3 +0.4 +12.5 4 286.099M 28.1 -28.4 +0.3 +0.4 +12.4 5 242.900M 28.8 -28.6 +0.3 +0.4 +11.7 6 282.299M 27.6 -28.5 +0.3 +0.4 +12.3 7 283.599M 27.6 -28.5 +0.3 +0.4 +12.3 8 261.099M 28.1 -28.5 +0.3 +0.3 +11.9 9 275.099M 27.6 -28.5 +0.3 +0.4 +12.1 T2=3.5' Cable AN 01189 T4=Cable 2410 T4 Test Distance: None Dist Corr Spec dB Table dBµV/m dBµV/m +2.9 +0.0 83.9 90.0 Margin Polar dB -6.1 Ant None +1.8 +0.0 44.4 90.0 -45.6 None +1.5 +0.0 14.6 90.0 -75.4 None +1.4 +0.0 14.2 90.0 -75.8 None +1.2 +0.0 13.8 90.0 -76.2 None +1.3 +0.0 13.4 90.0 -76.6 None +1.3 +0.0 13.4 90.0 -76.6 None +1.2 +0.0 13.3 90.0 -76.7 None +1.3 +0.0 13.2 90.0 -76.8 None Page 83 of 161 Report No.: MIL05-043 10 282.599M 27.4 11 270.299M 27.5 12 271.599M 27.5 13 279.599M 27.3 14 278.399M 27.2 15 209.100M 29.3 16 264.099M 27.5 17 266.099M 27.4 18 273.299M 27.3 19 273.899M 27.3 20 276.899M 27.1 21 222.600M 28.2 22 225.600M 28.1 23 264.699M 27.1 24 247.100M 27.3 25 220.200M 27.9 26 299.999M 25.4 27 214.100M 28.2 -28.5 +12.3 -28.5 +12.1 -28.5 +12.1 -28.5 +12.2 -28.5 +12.2 -28.8 +10.7 -28.5 +12.0 -28.5 +12.0 -28.5 +12.1 -28.5 +12.1 -28.5 +12.2 -28.7 +11.3 -28.6 +11.3 -28.5 +12.0 -28.6 +11.8 -28.7 +11.2 -28.5 +12.7 -28.8 +10.9 +0.3 +0.4 +1.3 +0.0 13.2 90.0 -76.8 None +0.3 +0.3 +1.3 +0.0 13.0 90.0 -77.0 None +0.3 +0.3 +1.3 +0.0 13.0 90.0 -77.0 None +0.3 +0.4 +1.3 +0.0 13.0 90.0 -77.0 None +0.3 +0.4 +1.3 +0.0 12.9 90.0 -77.1 None +0.2 +0.3 +1.1 +0.0 12.8 90.0 -77.2 None +0.3 +0.3 +1.2 +0.0 12.8 90.0 -77.2 None +0.3 +0.3 +1.3 +0.0 12.8 90.0 -77.2 None +0.3 +0.3 +1.3 +0.0 12.8 90.0 -77.2 None +0.3 +0.3 +1.3 +0.0 12.8 90.0 -77.2 None +0.3 +0.4 +1.3 +0.0 12.8 90.0 -77.2 None +0.2 +0.3 +1.1 +0.0 12.4 90.0 -77.6 None +0.2 +0.3 +1.1 +0.0 12.4 90.0 -77.6 None +0.3 +0.3 +1.2 +0.0 12.4 90.0 -77.6 None +0.3 +0.3 +1.2 +0.0 12.3 90.0 -77.7 None +0.2 +0.3 +1.1 +0.0 12.0 90.0 -78.0 None +0.3 +0.4 +1.7 +0.0 12.0 90.0 -78.0 None +0.2 +0.3 +1.1 +0.0 11.9 90.0 -78.1 None Page 84 of 161 Report No.: MIL05-043 28 219.600M 27.7 29 215.500M 27.9 30 214.900M 27.9 -28.7 +11.2 -28.7 +11.0 -28.8 +11.0 +0.2 +0.3 +1.1 +0.0 11.8 90.0 -78.2 None +0.2 +0.3 +1.1 +0.0 11.8 90.0 -78.2 None +0.2 +0.3 +1.1 +0.0 11.7 90.0 -78.3 None Page 85 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/19/2005 2:57:09 PM 5 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=8447D OPT 010 AN00686 SN 2944A08591 T3=Cable P05309 T5=SAS-570 Horn Antenna - 2525 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 T5 MHz dBµV dB dB dB 1 263.964M 54.2 -28.5 +0.3 +0.3 +12.0 2 240.040M 52.9 -28.6 +0.3 +0.4 +11.7 3 266.667M 50.4 -28.5 +0.3 +0.3 +12.0 4 528.028M 42.8 -29.8 +0.4 +0.6 +16.9 5 200.100M 49.4 -28.8 +0.2 +0.3 +10.3 T2=3.5' Cable AN 01189 T4=Cable 2410 T4 Test Distance: 1 Meter Dist Corr Spec Margin dB Table dBµV/m dBµV/m +1.2 +0.0 39.5 90.0 Polar dB -50.5 Ant Horiz +1.2 +0.0 37.9 90.0 -52.1 Horiz +1.3 +0.0 35.8 90.0 -54.2 Horiz +1.9 +0.0 32.8 90.0 -57.2 Horiz +1.0 +0.0 32.4 90.0 -57.6 Horiz Page 86 of 161 Report No.: MIL05-043 6 479.980M 41.0 7 675.175M 39.1 8 600.000M 36.2 9 459.960M 38.0 10 777.277M 33.5 11 551.952M 37.3 12 979.743M 29.4 13 431.932M 39.1 14 603.203M 34.8 15 947.868M 29.2 16 991.063M 28.1 17 983.715M 28.2 18 300.000M 38.7 19 975.870M 28.3 20 983.516M 28.1 21 312.012M 38.4 22 767.967M 31.9 23 957.698M 28.4 24 967.231M 28.4 25 969.018M 28.3 26 976.962M 28.2 -29.6 +17.2 -29.8 +17.9 -30.0 +18.1 -29.4 +15.7 -29.2 +19.0 -30.0 +16.2 -29.2 +22.2 -29.2 +14.1 -30.0 +18.0 -29.1 +21.6 -29.1 +22.5 -29.2 +22.3 -28.5 +12.7 -29.2 +22.1 -29.2 +22.3 -28.4 +13.1 -29.3 +18.9 -29.2 +21.8 -29.2 +21.9 -29.2 +22.0 -29.2 +22.1 +0.3 +0.5 +1.8 +0.0 31.2 90.0 -58.8 Horiz +0.5 +0.7 +2.3 +0.0 30.7 90.0 -59.3 Horiz +0.5 +0.5 +2.2 +0.0 27.5 90.0 -62.5 Horiz +0.3 +0.5 +1.9 +0.0 27.0 90.0 -63.0 Horiz +0.5 +0.6 +2.5 +0.0 26.9 90.0 -63.1 Horiz +0.4 +0.6 +2.0 +0.0 26.5 90.0 -63.5 Horiz +0.6 +0.7 +2.8 +0.0 26.5 90.0 -63.5 Horiz +0.3 +0.4 +1.7 +0.0 26.4 90.0 -63.6 Horiz +0.5 +0.5 +2.2 +0.0 26.0 90.0 -64.0 Horiz +0.6 +0.8 +2.9 +0.0 26.0 90.0 -64.0 Horiz +0.5 +0.8 +2.9 +0.0 25.7 90.0 -64.3 Horiz +0.6 +0.7 +2.8 +0.0 25.4 90.0 -64.6 Horiz +0.3 +0.4 +1.7 +0.0 25.3 90.0 -64.7 Horiz +0.6 +0.7 +2.8 +0.0 25.3 90.0 -64.7 Horiz +0.6 +0.7 +2.8 +0.0 25.3 90.0 -64.7 Horiz +0.3 +0.4 +1.4 +0.0 25.2 90.0 -64.8 Horiz +0.5 +0.7 +2.5 +0.0 25.2 90.0 -64.8 Horiz +0.6 +0.7 +2.9 +0.0 25.2 90.0 -64.8 Horiz +0.6 +0.7 +2.8 +0.0 25.2 90.0 -64.8 Horiz +0.6 +0.7 +2.8 +0.0 25.2 90.0 -64.8 Horiz +0.6 +0.7 +2.8 +0.0 25.2 90.0 -64.8 Horiz Page 87 of 161 Report No.: MIL05-043 27 996.326M 27.4 28 452.853M 36.5 29 580.080M 34.4 30 971.600M 28.0 -29.1 +22.7 -29.3 +15.3 -30.0 +17.7 -29.2 +22.0 +0.5 +0.8 +2.9 +0.0 25.2 90.0 -64.8 Horiz +0.3 +0.5 +1.8 +0.0 25.1 90.0 -64.9 Horiz +0.4 +0.6 +2.0 +0.0 25.1 90.0 -64.9 Horiz +0.6 +0.7 +2.8 +0.0 24.9 90.0 -65.1 Horiz Page 88 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/19/2005 2:52:46 PM 4 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=8447D OPT 010 AN00686 SN 2944A08591 T3=Cable P05309 T5=SAS-570 Horn Antenna - 2525 Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 T5 MHz dBµV dB dB dB 1 240.040M 56.8 -28.6 +0.3 +0.4 +11.7 2 600.000M 44.1 -30.0 +0.5 +0.5 +18.1 3 603.203M 42.9 -30.0 +0.5 +0.5 +18.0 4 479.980M 41.7 -29.6 +0.3 +0.5 +17.2 5 336.036M 44.6 -28.5 +0.4 +0.4 +13.2 T2=3.5' Cable AN 01189 T4=Cable 2410 T4 Test Distance: 1 Meter Dist Corr Spec Margin dB Table dBµV/m dBµV/m +1.2 +0.0 41.8 90.0 Polar dB -48.2 Ant Vert +2.2 +0.0 35.4 90.0 -54.6 Vert +2.2 +0.0 34.1 90.0 -55.9 Vert +1.8 +0.0 31.9 90.0 -58.1 Vert +1.5 +0.0 31.6 90.0 -58.4 Vert Page 89 of 161 Report No.: MIL05-043 6 559.960M 40.1 7 312.012M 41.9 8 200.100M 45.2 9 600.400M 36.9 10 959.982M 31.0 11 432.032M 40.3 12 551.952M 38.4 13 767.967M 33.6 14 528.028M 36.8 15 620.220M 36.1 16 989.971M 28.6 17 863.963M 31.4 18 825.024M 31.9 19 979.743M 28.8 20 992.950M 28.0 21 955.216M 28.8 22 973.487M 28.5 23 980.140M 28.3 24 890.990M 30.2 25 945.584M 28.5 26 994.042M 27.5 27 953.230M 28.4 -30.0 +16.1 -28.4 +13.1 -28.8 +10.3 -30.0 +18.1 -29.2 +21.8 -29.2 +14.1 -30.0 +16.2 -29.3 +18.9 -29.8 +16.9 -30.0 +17.5 -29.1 +22.5 -29.1 +19.7 -29.2 +19.4 -29.2 +22.2 -29.1 +22.6 -29.2 +21.7 -29.2 +22.1 -29.2 +22.2 -29.1 +20.3 -29.1 +21.5 -29.1 +22.6 -29.2 +21.7 +0.4 +0.6 +2.0 +0.0 29.2 90.0 -60.8 Vert +0.3 +0.4 +1.4 +0.0 28.7 90.0 -61.3 Vert +0.2 +0.3 +1.0 +0.0 28.2 90.0 -61.8 Vert +0.5 +0.5 +2.2 +0.0 28.2 90.0 -61.8 Vert +0.6 +0.7 +2.9 +0.0 27.8 90.0 -62.2 Vert +0.3 +0.4 +1.7 +0.0 27.6 90.0 -62.4 Vert +0.4 +0.6 +2.0 +0.0 27.6 90.0 -62.4 Vert +0.5 +0.7 +2.5 +0.0 26.9 90.0 -63.1 Vert +0.4 +0.6 +1.9 +0.0 26.8 90.0 -63.2 Vert +0.4 +0.5 +2.2 +0.0 26.7 90.0 -63.3 Vert +0.5 +0.8 +2.9 +0.0 26.2 90.0 -63.8 Vert +0.6 +0.7 +2.7 +0.0 26.0 90.0 -64.0 Vert +0.5 +0.6 +2.7 +0.0 25.9 90.0 -64.1 Vert +0.6 +0.7 +2.8 +0.0 25.9 90.0 -64.1 Vert +0.5 +0.8 +2.9 +0.0 25.7 90.0 -64.3 Vert +0.6 +0.7 +2.9 +0.0 25.5 90.0 -64.5 Vert +0.6 +0.7 +2.8 +0.0 25.5 90.0 -64.5 Vert +0.6 +0.7 +2.8 +0.0 25.4 90.0 -64.6 Vert +0.5 +0.7 +2.7 +0.0 25.3 90.0 -64.7 Vert +0.6 +0.8 +2.9 +0.0 25.2 90.0 -64.8 Vert +0.5 +0.8 +2.9 +0.0 25.2 90.0 -64.8 Vert +0.6 +0.7 +2.9 +0.0 25.1 90.0 -64.9 Vert Page 90 of 161 Report No.: MIL05-043 28 957.798M 28.3 29 972.593M 28.1 30 931.483M 28.7 -29.2 +21.8 -29.2 +22.1 -29.1 +21.2 +0.6 +0.7 +2.9 +0.0 25.1 90.0 -64.9 Vert +0.6 +0.7 +2.8 +0.0 25.1 90.0 -64.9 Vert +0.6 +0.8 +2.8 +0.0 25.0 90.0 -65.0 Vert Page 91 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Test Equipment: Function SA - E4446A S/N US44300408 Calibration Date 01/13/2005 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/20/2005 10:52:06 AM 11 A. Brar Cal Due Date 01/13/2007 Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM Asset # 02668 S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 1195.340M 55.9 +24.5 -39.7 +1.5 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +1.4 +0.0 43.6 90.0 -46.4 Polar Ant Horiz 2 1199.709M 53.4 +24.5 -39.7 +1.5 +1.4 +0.0 41.1 90.0 -48.9 Horiz 3 1022.336M 54.1 +24.0 -40.5 +1.4 +1.3 +0.0 40.3 90.0 -49.7 Horiz 4 1061.345M 53.8 +24.1 -40.3 +1.4 +1.3 +0.0 40.3 90.0 -49.7 Horiz Page 92 of 161 Report No.: MIL05-043 5 1191.335M 52.0 +24.5 -39.7 +1.5 +1.4 +0.0 39.7 90.0 -50.3 Horiz 6 1051.593M 53.2 +24.1 -40.4 +1.4 +1.3 +0.0 39.6 90.0 -50.4 Horiz 7 1482.164M 49.6 +25.3 -38.7 +1.7 +1.6 +0.0 39.5 90.0 -50.5 Horiz 8 1328.044M 50.6 +24.9 -39.2 +1.6 +1.5 +0.0 39.4 90.0 -50.6 Horiz 9 1162.027M 51.9 +24.4 -39.9 +1.5 +1.4 +0.0 39.3 90.0 -50.7 Horiz 10 1326.588M 50.5 +24.9 -39.2 +1.6 +1.5 +0.0 39.3 90.0 -50.7 Horiz 11 1475.844M 49.4 +25.2 -38.7 +1.7 +1.6 +0.0 39.2 90.0 -50.8 Horiz 12 1376.830M 50.0 +25.0 -39.0 +1.6 +1.5 +0.0 39.1 90.0 -50.9 Horiz 13 1536.096M 48.7 +25.5 -38.6 +1.7 +1.7 +0.0 39.0 90.0 -51.0 Horiz 14 1099.096M 51.8 +24.2 -40.1 +1.5 +1.4 +0.0 38.8 90.0 -51.2 Horiz 15 1358.712M 49.8 +25.0 -39.1 +1.6 +1.5 +0.0 38.8 90.0 -51.2 Horiz 16 1501.546M 48.8 +25.3 -38.6 +1.7 +1.6 +0.0 38.8 90.0 -51.2 Horiz 17 1546.208M 48.3 +25.6 -38.5 +1.7 +1.7 +0.0 38.8 90.0 -51.2 Horiz 18 1145.183M 51.3 +24.4 -39.9 +1.5 +1.4 +0.0 38.7 90.0 -51.3 Horiz 19 1189.151M 51.0 +24.5 -39.7 +1.5 +1.4 +0.0 38.7 90.0 -51.3 Horiz 20 1358.080M 49.6 +25.0 -39.1 +1.6 +1.5 +0.0 38.6 90.0 -51.4 Horiz 21 1483.850M 48.7 +25.3 -38.7 +1.7 +1.6 +0.0 38.6 90.0 -51.4 Horiz 22 1519.242M 48.5 +25.4 -38.6 +1.7 +1.6 +0.0 38.6 90.0 -51.4 Horiz 23 1166.396M 51.0 +24.4 -39.8 +1.5 +1.4 +0.0 38.5 90.0 -51.5 Horiz 24 1250.315M 50.3 +24.7 -39.5 +1.5 +1.5 +0.0 38.5 90.0 -51.5 Horiz 25 1442.348M 48.9 +25.2 -38.8 +1.6 +1.6 +0.0 38.5 90.0 -51.5 Horiz 26 1519.664M 48.4 +25.4 -38.6 +1.7 +1.6 +0.0 38.5 90.0 -51.5 Horiz Page 93 of 161 Report No.: MIL05-043 27 1153.519M 51.0 +24.4 -39.9 +1.5 +1.4 +0.0 38.4 90.0 -51.6 Horiz 28 1168.945M 50.9 +24.4 -39.8 +1.5 +1.4 +0.0 38.4 90.0 -51.6 Horiz 29 1505.759M 48.3 +25.3 -38.6 +1.7 +1.6 +0.0 38.3 90.0 -51.7 Horiz 30 1513.976M 48.2 +25.4 -38.6 +1.7 +1.6 +0.0 38.3 90.0 -51.7 Horiz Page 94 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/20/2005 8:57:42 AM 6 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 1084.782M 56.5 +24.2 -40.2 +1.5 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +1.4 +0.0 43.4 90.0 -46.6 Polar Ant Vert 2 1133.071M 53.6 +24.3 -40.0 +1.5 +1.4 +0.0 40.8 90.0 -49.2 Vert 3 1161.845M 53.1 +24.4 -39.9 +1.5 +1.4 +0.0 40.5 90.0 -49.5 Vert 4 1327.680M 51.0 +24.9 -39.2 +1.6 +1.5 +0.0 39.8 90.0 -50.2 Vert 5 1333.688M 50.9 +24.9 -39.2 +1.6 +1.5 +0.0 39.7 90.0 -50.3 Vert 6 1377.462M 50.4 +25.0 -39.0 +1.6 +1.5 +0.0 39.5 90.0 -50.5 Vert Page 95 of 161 Report No.: MIL05-043 7 1359.976M 50.4 +25.0 -39.1 +1.6 +1.5 +0.0 39.4 90.0 -50.6 Vert 8 1194.612M 51.6 +24.5 -39.7 +1.5 +1.4 +0.0 39.3 90.0 -50.7 Vert 9 1364.611M 50.1 +25.0 -39.1 +1.6 +1.5 +0.0 39.1 90.0 -50.9 Vert 10 1500.703M 49.1 +25.3 -38.6 +1.7 +1.6 +0.0 39.1 90.0 -50.9 Vert 11 1536.096M 48.8 +25.5 -38.6 +1.7 +1.7 +0.0 39.1 90.0 -50.9 Vert 12 1000.157M 53.0 +23.9 -40.6 +1.4 +1.3 +0.0 39.0 90.0 -51.0 Vert 13 1361.240M 50.0 +25.0 -39.1 +1.6 +1.5 +0.0 39.0 90.0 -51.0 Vert 14 1433.710M 49.5 +25.1 -38.8 +1.6 +1.6 +0.0 39.0 90.0 -51.0 Vert 15 1539.888M 48.7 +25.5 -38.6 +1.7 +1.7 +0.0 39.0 90.0 -51.0 Vert 16 1114.196M 51.8 +24.3 -40.1 +1.5 +1.4 +0.0 38.9 90.0 -51.1 Vert 17 1518.610M 48.8 +25.4 -38.6 +1.7 +1.6 +0.0 38.9 90.0 -51.1 Vert 18 1352.392M 49.9 +24.9 -39.1 +1.6 +1.5 +0.0 38.8 90.0 -51.2 Vert 19 1408.219M 49.5 +25.1 -38.9 +1.6 +1.5 +0.0 38.8 90.0 -51.2 Vert 20 1539.045M 48.5 +25.5 -38.6 +1.7 +1.7 +0.0 38.8 90.0 -51.2 Vert 21 1330.411M 49.9 +24.9 -39.2 +1.6 +1.5 +0.0 38.7 90.0 -51.3 Vert 22 1398.318M 49.4 +25.1 -38.9 +1.6 +1.5 +0.0 38.7 90.0 -51.3 Vert 23 1523.456M 48.6 +25.4 -38.6 +1.7 +1.6 +0.0 38.7 90.0 -51.3 Vert 24 1527.248M 48.4 +25.5 -38.6 +1.7 +1.7 +0.0 38.7 90.0 -51.3 Vert 25 1530.829M 48.4 +25.5 -38.6 +1.7 +1.7 +0.0 38.7 90.0 -51.3 Vert 26 1045.615M 52.2 +24.1 -40.4 +1.4 +1.3 +0.0 38.6 90.0 -51.4 Vert 27 1210.267M 50.8 +24.6 -39.7 +1.5 +1.4 +0.0 38.6 90.0 -51.4 Vert Page 96 of 161 Report No.: MIL05-043 28 1369.035M 49.6 +25.0 -39.1 +1.6 +1.5 +0.0 38.6 90.0 -51.4 Vert 29 1316.394M 49.8 +24.8 -39.2 +1.6 +1.5 +0.0 38.5 90.0 -51.5 Vert 30 1510.394M 48.4 +25.4 -38.6 +1.7 +1.6 +0.0 38.5 90.0 -51.5 Vert Page 97 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/20/2005 11:45:23 AM 15 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 1597.441M 22.5 +25.8 -38.5 +1.7 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +1.7 +0.0 13.2 14.0 -0.8 Polar Ant Horiz 2 1587.883M 22.2 +25.8 -38.5 +1.7 +1.7 +0.0 12.9 14.0 -1.1 Horiz 3 1598.179M 22.0 +25.8 -38.5 +1.7 +1.7 +0.0 12.7 14.0 -1.3 Horiz 4 1553.051M 22.1 +25.6 -38.5 +1.7 +1.7 +0.0 12.6 14.0 -1.4 Horiz 5 1595.423M 21.8 +25.8 -38.5 +1.7 +1.7 +0.0 12.5 14.0 -1.5 Horiz 6 1586.342M 21.7 +25.8 -38.5 +1.7 +1.7 +0.0 12.4 14.0 -1.6 Horiz Page 98 of 161 Report No.: MIL05-043 7 1597.883M 21.7 +25.8 -38.5 +1.7 +1.7 +0.0 12.4 14.0 -1.6 Horiz 8 1576.886M 21.7 +25.7 -38.5 +1.7 +1.7 +0.0 12.3 14.0 -1.7 Horiz 9 1579.021M 21.7 +25.7 -38.5 +1.7 +1.7 +0.0 12.3 14.0 -1.7 Horiz 10 1596.856M 21.6 +25.8 -38.5 +1.7 +1.7 +0.0 12.3 14.0 -1.7 Horiz 11 1594.183M 21.5 +25.8 -38.5 +1.7 +1.7 +0.0 12.2 14.0 -1.8 Horiz 12 1599.190M 21.5 +25.8 -38.5 +1.7 +1.7 +0.0 12.2 14.0 -1.8 Horiz 13 1555.102M 21.6 +25.6 -38.5 +1.7 +1.7 +0.0 12.1 14.0 -1.9 Horiz 14 1574.766M 21.5 +25.7 -38.5 +1.7 +1.7 +0.0 12.1 14.0 -1.9 Horiz 15 1582.060M 21.5 +25.7 -38.5 +1.7 +1.7 +0.0 12.1 14.0 -1.9 Horiz 16 1589.820M 21.4 +25.8 -38.5 +1.7 +1.7 +0.0 12.1 14.0 -1.9 Horiz 17 1596.387M 21.4 +25.8 -38.5 +1.7 +1.7 +0.0 12.1 14.0 -1.9 Horiz 18 1598.304M 21.4 +25.8 -38.5 +1.7 +1.7 +0.0 12.1 14.0 -1.9 Horiz 19 1572.219M 21.4 +25.7 -38.5 +1.7 +1.7 +0.0 12.0 14.0 -2.0 Horiz 20 1574.775M 21.4 +25.7 -38.5 +1.7 +1.7 +0.0 12.0 14.0 -2.0 Horiz 21 1579.868M 21.4 +25.7 -38.5 +1.7 +1.7 +0.0 12.0 14.0 -2.0 Horiz 22 1588.297M 21.3 +25.8 -38.5 +1.7 +1.7 +0.0 12.0 14.0 -2.0 Horiz 23 1558.054M 21.4 +25.6 -38.5 +1.7 +1.7 +0.0 11.9 14.0 -2.1 Horiz 24 1559.970M 21.4 +25.6 -38.5 +1.7 +1.7 +0.0 11.9 14.0 -2.1 Horiz 25 1573.246M 21.3 +25.7 -38.5 +1.7 +1.7 +0.0 11.9 14.0 -2.1 Horiz 26 1590.919M 21.2 +25.8 -38.5 +1.7 +1.7 +0.0 11.9 14.0 -2.1 Horiz 27 1597.324M 21.2 +25.8 -38.5 +1.7 +1.7 +0.0 11.9 14.0 -2.1 Horiz Page 99 of 161 Report No.: MIL05-043 28 1570.799M 21.2 +25.7 -38.5 +1.7 +1.7 +0.0 11.8 14.0 -2.2 Horiz 29 1579.925M 21.2 +25.7 -38.5 +1.7 +1.7 +0.0 11.8 14.0 -2.2 Horiz 30 1591.552M 21.1 +25.8 -38.5 +1.7 +1.7 +0.0 11.8 14.0 -2.2 Horiz Page 100 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 1KHz RBW 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/20/2005 1:29:39 PM 19 A. Brar Model # SIU S/N GLAT 2508 Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Foil wrapped around J7. Foil from top of the unit to the copper table. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 1552.897M 22.9 +25.6 -38.5 +1.7 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +1.7 +0.0 13.4 14.0 -0.6 Polar Ant Vert 2 1584.213M 20.4 +25.8 -38.5 +1.7 +1.7 +0.0 11.1 14.0 -2.9 Vert 3 1597.442M 20.3 +25.8 -38.5 +1.7 +1.7 +0.0 11.0 14.0 -3.0 Vert 4 1582.952M 19.8 +25.7 -38.5 +1.7 +1.7 +0.0 10.4 14.0 -3.6 Vert 5 1562.915M 18.7 +25.6 -38.5 +1.7 +1.7 +0.0 9.2 14.0 -4.8 Vert Page 101 of 161 Report No.: MIL05-043 6 1595.277M 18.5 +25.8 -38.5 +1.7 +1.7 +0.0 9.2 14.0 -4.8 Vert 7 1592.687M 18.3 +25.8 -38.5 +1.7 +1.7 +0.0 9.0 14.0 -5.0 Vert 8 1597.490M 18.2 +25.8 -38.5 +1.7 +1.7 +0.0 8.9 14.0 -5.1 Vert 9 1572.398M 17.9 +25.7 -38.5 +1.7 +1.7 +0.0 8.5 14.0 -5.5 Vert 10 1582.655M 17.9 +25.7 -38.5 +1.7 +1.7 +0.0 8.5 14.0 -5.5 Vert 11 1592.479M 17.8 +25.8 -38.5 +1.7 +1.7 +0.0 8.5 14.0 -5.5 Vert 12 1592.503M 17.7 +25.8 -38.5 +1.7 +1.7 +0.0 8.4 14.0 -5.6 Vert 13 1559.988M 17.8 +25.6 -38.5 +1.7 +1.7 +0.0 8.3 14.0 -5.7 Vert 14 1592.148M 17.6 +25.8 -38.5 +1.7 +1.7 +0.0 8.3 14.0 -5.7 Vert 15 1550.077M 17.7 +25.6 -38.5 +1.7 +1.7 +0.0 8.2 14.0 -5.8 Vert 16 1575.157M 17.5 +25.7 -38.5 +1.7 +1.7 +0.0 8.1 14.0 -5.9 Vert 17 1588.289M 17.4 +25.8 -38.5 +1.7 +1.7 +0.0 8.1 14.0 -5.9 Vert 18 1577.941M 17.4 +25.7 -38.5 +1.7 +1.7 +0.0 8.0 14.0 -6.0 Vert 19 1592.238M 17.3 +25.8 -38.5 +1.7 +1.7 +0.0 8.0 14.0 -6.0 Vert 20 1550.598M 17.4 +25.6 -38.5 +1.7 +1.7 +0.0 7.9 14.0 -6.1 Vert 21 1592.823M 17.2 +25.8 -38.5 +1.7 +1.7 +0.0 7.9 14.0 -6.1 Vert 22 1553.176M 17.3 +25.6 -38.5 +1.7 +1.7 +0.0 7.8 14.0 -6.2 Vert 23 1575.426M 17.2 +25.7 -38.5 +1.7 +1.7 +0.0 7.8 14.0 -6.2 Vert 24 1591.227M 17.1 +25.8 -38.5 +1.7 +1.7 +0.0 7.8 14.0 -6.2 Vert 25 1591.531M 17.1 +25.8 -38.5 +1.7 +1.7 +0.0 7.8 14.0 -6.2 Vert 26 1596.227M 17.1 +25.8 -38.5 +1.7 +1.7 +0.0 7.8 14.0 -6.2 Vert Page 102 of 161 Report No.: MIL05-043 27 1583.030M 17.1 +25.7 -38.5 +1.7 +1.7 +0.0 7.7 14.0 -6.3 Vert 28 1591.284M 17.0 +25.8 -38.5 +1.7 +1.7 +0.0 7.7 14.0 -6.3 Vert 29 1594.497M 17.0 +25.8 -38.5 +1.7 +1.7 +0.0 7.7 14.0 -6.3 Vert 30 1575.048M 17.0 +25.7 -38.5 +1.7 +1.7 +0.0 7.6 14.0 -6.4 Vert Page 103 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/20/2005 10:53:46 AM 12 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 1728.640M 49.8 +26.5 -38.4 +1.8 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +1.8 +0.0 41.5 90.0 -48.5 Polar Ant Horiz 2 1767.129M 49.4 +26.7 -38.3 +1.8 +1.8 +0.0 41.4 90.0 -48.6 Horiz 3 1730.807M 49.6 +26.5 -38.4 +1.8 +1.8 +0.0 41.3 90.0 -48.7 Horiz 4 1681.507M 49.5 +26.3 -38.4 +1.8 +1.8 +0.0 41.0 90.0 -49.0 Horiz 5 1635.272M 49.8 +26.0 -38.4 +1.8 +1.7 +0.0 40.9 90.0 -49.1 Horiz 6 1749.613M 49.0 +26.6 -38.3 +1.8 +1.8 +0.0 40.9 90.0 -49.1 Horiz Page 104 of 161 Report No.: MIL05-043 7 1611.830M 50.0 +25.9 -38.5 +1.7 +1.7 +0.0 40.8 90.0 -49.2 Horiz 8 1719.266M 49.2 +26.4 -38.4 +1.8 +1.8 +0.0 40.8 90.0 -49.2 Horiz 9 1727.292M 49.1 +26.5 -38.4 +1.8 +1.8 +0.0 40.8 90.0 -49.2 Horiz 10 1760.216M 48.9 +26.6 -38.3 +1.8 +1.8 +0.0 40.8 90.0 -49.2 Horiz 11 1762.677M 48.9 +26.6 -38.3 +1.8 +1.8 +0.0 40.8 90.0 -49.2 Horiz 12 1650.498M 49.5 +26.1 -38.4 +1.8 +1.7 +0.0 40.7 90.0 -49.3 Horiz 13 1682.753M 49.2 +26.3 -38.4 +1.8 +1.8 +0.0 40.7 90.0 -49.3 Horiz 14 1742.758M 48.8 +26.6 -38.3 +1.8 +1.8 +0.0 40.7 90.0 -49.3 Horiz 15 1761.095M 48.8 +26.6 -38.3 +1.8 +1.8 +0.0 40.7 90.0 -49.3 Horiz 16 1600.274M 49.9 +25.8 -38.5 +1.7 +1.7 +0.0 40.6 90.0 -49.4 Horiz 17 1627.659M 49.6 +26.0 -38.5 +1.8 +1.7 +0.0 40.6 90.0 -49.4 Horiz 18 1714.286M 49.0 +26.4 -38.4 +1.8 +1.8 +0.0 40.6 90.0 -49.4 Horiz 19 1760.685M 48.7 +26.6 -38.3 +1.8 +1.8 +0.0 40.6 90.0 -49.4 Horiz 20 1702.013M 48.9 +26.4 -38.4 +1.8 +1.8 +0.0 40.5 90.0 -49.5 Horiz 21 1672.500M 49.1 +26.2 -38.4 +1.8 +1.7 +0.0 40.4 90.0 -49.6 Horiz 22 1674.653M 49.1 +26.2 -38.4 +1.8 +1.7 +0.0 40.4 90.0 -49.6 Horiz 23 1685.359M 48.9 +26.3 -38.4 +1.8 +1.8 +0.0 40.4 90.0 -49.6 Horiz 24 1699.577M 48.9 +26.3 -38.4 +1.8 +1.8 +0.0 40.4 90.0 -49.6 Horiz 25 1659.189M 49.1 +26.1 -38.4 +1.8 +1.7 +0.0 40.3 90.0 -49.7 Horiz 26 1666.326M 49.0 +26.2 -38.4 +1.8 +1.7 +0.0 40.3 90.0 -49.7 Horiz Page 105 of 161 Report No.: MIL05-043 27 1712.470M 48.7 +26.4 -38.4 +1.8 +1.8 +0.0 40.3 90.0 -49.7 Horiz 28 1724.597M 48.6 +26.5 -38.4 +1.8 +1.8 +0.0 40.3 90.0 -49.7 Horiz 29 1734.615M 48.5 +26.5 -38.3 +1.8 +1.8 +0.0 40.3 90.0 -49.7 Horiz 30 1739.595M 48.5 +26.5 -38.3 +1.8 +1.8 +0.0 40.3 90.0 -49.7 Horiz Page 106 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/20/2005 9:00:09 AM 7 A. Brar Model # SIU S/N GLAT 2508 Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 1763.790M 49.4 +26.7 -38.3 +1.8 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +1.8 +0.0 41.4 90.0 -48.6 Polar Ant Vert 2 1767.481M 49.3 +26.7 -38.3 +1.8 +1.8 +0.0 41.3 90.0 -48.7 Vert 3 1768.008M 49.0 +26.7 -38.3 +1.8 +1.8 +0.0 41.0 90.0 -49.0 Vert 4 1762.091M 49.0 +26.6 -38.3 +1.8 +1.8 +0.0 40.9 90.0 -49.1 Vert 5 1762.384M 49.0 +26.6 -38.3 +1.8 +1.8 +0.0 40.9 90.0 -49.1 Vert 6 1763.497M 48.8 +26.7 -38.3 +1.8 +1.8 +0.0 40.8 90.0 -49.2 Vert Page 107 of 161 Report No.: MIL05-043 7 1710.113M 49.1 +26.4 -38.4 +1.8 +1.8 +0.0 40.7 90.0 -49.3 Vert 8 1755.940M 48.8 +26.6 -38.3 +1.8 +1.8 +0.0 40.7 90.0 -49.3 Vert 9 1675.786M 49.2 +26.2 -38.4 +1.8 +1.8 +0.0 40.6 90.0 -49.4 Vert 10 1754.651M 48.7 +26.6 -38.3 +1.8 +1.8 +0.0 40.6 90.0 -49.4 Vert 11 1679.411M 49.1 +26.2 -38.4 +1.8 +1.8 +0.0 40.5 90.0 -49.5 Vert 12 1700.710M 49.0 +26.3 -38.4 +1.8 +1.8 +0.0 40.5 90.0 -49.5 Vert 13 1711.359M 48.9 +26.4 -38.4 +1.8 +1.8 +0.0 40.5 90.0 -49.5 Vert 14 1713.642M 48.9 +26.4 -38.4 +1.8 +1.8 +0.0 40.5 90.0 -49.5 Vert 15 1727.409M 48.8 +26.5 -38.4 +1.8 +1.8 +0.0 40.5 90.0 -49.5 Vert 16 1731.452M 48.8 +26.5 -38.4 +1.8 +1.8 +0.0 40.5 90.0 -49.5 Vert 17 1618.074M 49.6 +25.9 -38.5 +1.7 +1.7 +0.0 40.4 90.0 -49.6 Vert 18 1733.209M 48.6 +26.5 -38.3 +1.8 +1.8 +0.0 40.4 90.0 -49.6 Vert 19 1754.768M 48.5 +26.6 -38.3 +1.8 +1.8 +0.0 40.4 90.0 -49.6 Vert 20 1628.974M 49.2 +26.0 -38.5 +1.8 +1.7 +0.0 40.2 90.0 -49.8 Vert 21 1707.904M 48.6 +26.4 -38.4 +1.8 +1.8 +0.0 40.2 90.0 -49.8 Vert 22 1634.012M 49.0 +26.0 -38.5 +1.8 +1.7 +0.0 40.0 90.0 -50.0 Vert 23 1650.882M 48.8 +26.1 -38.4 +1.8 +1.7 +0.0 40.0 90.0 -50.0 Vert 24 1701.446M 48.4 +26.4 -38.4 +1.8 +1.8 +0.0 40.0 90.0 -50.0 Vert 25 1702.409M 48.4 +26.4 -38.4 +1.8 +1.8 +0.0 40.0 90.0 -50.0 Vert 26 1640.201M 48.8 +26.0 -38.4 +1.8 +1.7 +0.0 39.9 90.0 -50.1 Vert 27 1645.624M 48.7 +26.1 -38.4 +1.8 +1.7 +0.0 39.9 90.0 -50.1 Vert Page 108 of 161 Report No.: MIL05-043 28 1705.185M 48.3 +26.4 -38.4 +1.8 +1.8 +0.0 39.9 90.0 -50.1 Vert 29 1633.410M 48.8 +26.0 -38.5 +1.8 +1.7 +0.0 39.8 90.0 -50.2 Vert 30 1648.034M 48.6 +26.1 -38.4 +1.8 +1.7 +0.0 39.8 90.0 -50.2 Vert Page 109 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/20/2005 11:39:34 AM 14 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 2196.486M 29.8 +27.9 -38.0 +2.0 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +2.0 +0.0 23.7 25.0 -1.3 Polar Ant Horiz 2 2100.000M 28.0 +27.8 -38.0 +2.0 +1.9 +0.0 21.7 25.0 -3.3 Horiz 3 1803.503M 29.1 +26.8 -38.3 +1.8 +1.8 +0.0 21.2 25.0 -3.8 Horiz 4 2259.329M 26.8 +27.9 -37.9 +2.1 +2.0 +0.0 20.9 25.0 -4.1 Horiz 5 2077.107M 27.1 +27.8 -38.0 +2.0 +1.9 +0.0 20.8 25.0 -4.2 Horiz 6 2103.934M 27.0 +27.8 -38.0 +2.0 +1.9 +0.0 20.7 25.0 -4.3 Horiz Page 110 of 161 Report No.: MIL05-043 7 1929.469M 27.6 +27.4 -38.2 +1.9 +1.9 +0.0 20.6 25.0 -4.4 Horiz 8 2118.478M 26.9 +27.8 -38.0 +2.0 +1.9 +0.0 20.6 25.0 -4.4 Horiz 9 1974.144M 27.2 +27.6 -38.1 +1.9 +1.9 +0.0 20.5 25.0 -4.5 Horiz 10 2237.487M 26.5 +27.9 -37.9 +2.0 +2.0 +0.0 20.5 25.0 -4.5 Horiz 11 2291.705M 26.4 +27.9 -37.9 +2.1 +2.0 +0.0 20.5 25.0 -4.5 Horiz 12 2037.487M 27.0 +27.7 -38.1 +1.9 +1.9 +0.0 20.4 25.0 -4.6 Horiz 13 2038.749M 27.0 +27.7 -38.1 +1.9 +1.9 +0.0 20.4 25.0 -4.6 Horiz 14 2078.909M 26.7 +27.8 -38.0 +2.0 +1.9 +0.0 20.4 25.0 -4.6 Horiz 15 2219.939M 26.5 +27.9 -38.0 +2.0 +2.0 +0.0 20.4 25.0 -4.6 Horiz 16 1925.355M 27.3 +27.4 -38.2 +1.9 +1.9 +0.0 20.3 25.0 -4.7 Horiz 17 2085.305M 26.6 +27.8 -38.0 +2.0 +1.9 +0.0 20.3 25.0 -4.7 Horiz 18 2118.538M 26.6 +27.8 -38.0 +2.0 +1.9 +0.0 20.3 25.0 -4.7 Horiz 19 2127.697M 26.6 +27.8 -38.0 +2.0 +1.9 +0.0 20.3 25.0 -4.7 Horiz 20 2181.511M 26.4 +27.9 -38.0 +2.0 +2.0 +0.0 20.3 25.0 -4.7 Horiz 21 2230.640M 26.4 +27.9 -38.0 +2.0 +2.0 +0.0 20.3 25.0 -4.7 Horiz 22 2256.476M 26.2 +27.9 -37.9 +2.1 +2.0 +0.0 20.3 25.0 -4.7 Horiz 23 2292.938M 26.2 +27.9 -37.9 +2.1 +2.0 +0.0 20.3 25.0 -4.7 Horiz 24 1873.083M 27.5 +27.2 -38.2 +1.9 +1.8 +0.0 20.2 25.0 -4.8 Horiz 25 2033.764M 26.8 +27.7 -38.1 +1.9 +1.9 +0.0 20.2 25.0 -4.8 Horiz 26 2091.031M 26.5 +27.8 -38.0 +2.0 +1.9 +0.0 20.2 25.0 -4.8 Horiz 27 2152.512M 26.4 +27.8 -38.0 +2.0 +2.0 +0.0 20.2 25.0 -4.8 Horiz Page 111 of 161 Report No.: MIL05-043 28 2224.905M 26.3 +27.9 -38.0 +2.0 +2.0 +0.0 20.2 25.0 -4.8 Horiz 29 2258.428M 26.1 +27.9 -37.9 +2.1 +2.0 +0.0 20.2 25.0 -4.8 Horiz 30 2266.306M 26.0 +27.9 -37.9 +2.1 +2.0 +0.0 20.1 25.0 -4.9 Horiz Page 112 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/20/2005 10:46:34 AM 10 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 2196.486M 29.4 +27.9 -38.0 +2.0 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +2.0 +0.0 23.3 25.0 -1.7 Polar Ant Vert 2 2103.833M 29.5 +27.8 -38.0 +2.0 +1.9 +0.0 23.2 25.0 -1.8 Vert 3 1803.293M 30.8 +26.8 -38.3 +1.8 +1.8 +0.0 22.9 25.0 -2.1 Vert 4 1991.742M 28.9 +27.7 -38.1 +1.9 +1.9 +0.0 22.3 25.0 -2.7 Vert 5 1797.117M 29.9 +26.8 -38.3 +1.8 +1.8 +0.0 22.0 25.0 -3.0 Vert 6 2026.596M 27.9 +27.7 -38.1 +1.9 +1.9 +0.0 21.3 25.0 -3.7 Vert Page 113 of 161 Report No.: MIL05-043 7 1994.975M 27.8 +27.7 -38.1 +1.9 +1.9 +0.0 21.2 25.0 -3.8 Vert 8 2098.328M 27.3 +27.8 -38.0 +2.0 +1.9 +0.0 21.0 25.0 -4.0 Vert 9 1979.709M 27.6 +27.6 -38.1 +1.9 +1.9 +0.0 20.9 25.0 -4.1 Vert 10 1996.807M 27.5 +27.7 -38.1 +1.9 +1.9 +0.0 20.9 25.0 -4.1 Vert 11 2103.653M 27.1 +27.8 -38.0 +2.0 +1.9 +0.0 20.8 25.0 -4.2 Vert 12 2193.303M 26.9 +27.9 -38.0 +2.0 +2.0 +0.0 20.8 25.0 -4.2 Vert 13 1797.147M 28.6 +26.8 -38.3 +1.8 +1.8 +0.0 20.7 25.0 -4.3 Vert 14 1946.416M 27.5 +27.5 -38.1 +1.9 +1.9 +0.0 20.7 25.0 -4.3 Vert 15 2029.079M 27.3 +27.7 -38.1 +1.9 +1.9 +0.0 20.7 25.0 -4.3 Vert 16 2078.438M 27.0 +27.8 -38.0 +2.0 +1.9 +0.0 20.7 25.0 -4.3 Vert 17 2173.163M 26.9 +27.8 -38.0 +2.0 +2.0 +0.0 20.7 25.0 -4.3 Vert 18 1822.693M 28.4 +26.9 -38.3 +1.8 +1.8 +0.0 20.6 25.0 -4.4 Vert 19 2188.958M 26.7 +27.9 -38.0 +2.0 +2.0 +0.0 20.6 25.0 -4.4 Vert 20 2212.642M 26.6 +27.9 -38.0 +2.0 +2.0 +0.0 20.5 25.0 -4.5 Vert 21 2037.287M 27.0 +27.7 -38.1 +1.9 +1.9 +0.0 20.4 25.0 -4.6 Vert 22 2075.775M 26.8 +27.8 -38.1 +2.0 +1.9 +0.0 20.4 25.0 -4.6 Vert 23 2085.035M 26.7 +27.8 -38.0 +2.0 +1.9 +0.0 20.4 25.0 -4.6 Vert 24 2088.568M 26.7 +27.8 -38.0 +2.0 +1.9 +0.0 20.4 25.0 -4.6 Vert 25 2125.405M 26.7 +27.8 -38.0 +2.0 +1.9 +0.0 20.4 25.0 -4.6 Vert 26 2129.850M 26.7 +27.8 -38.0 +2.0 +1.9 +0.0 20.4 25.0 -4.6 Vert Page 114 of 161 Report No.: MIL05-043 27 2095.005M 26.6 +27.8 -38.0 +2.0 +1.9 +0.0 20.3 25.0 -4.7 Vert 28 2219.619M 26.4 +27.9 -38.0 +2.0 +2.0 +0.0 20.3 25.0 -4.7 Vert 29 2241.661M 26.3 +27.9 -37.9 +2.0 +2.0 +0.0 20.3 25.0 -4.7 Vert 30 2260.970M 26.2 +27.9 -37.9 +2.1 +2.0 +0.0 20.3 25.0 -4.7 Vert Page 115 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Date: Time: Sequence#: Tested By: 10/20/2005 8:28:29 AM 0 A. Brar Equipment Under Test (* = EUT): Function Manufacturer Model # S/N Support Devices: Function Model # S/N Manufacturer Test Conditions / Notes: Path Check Sweep. Signal at 1000.00MHz. 90 (spec limit) - 6dB - 45.9 (Antenna Factor) = 38.1dBuV = -68.9dBm signal level. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 17995.080M 61.8 +45.9 -33.5 +6.4 Test Distance: None T4 Dist Corr Spec dB Table dBµV/m dBµV/m +5.9 +0.0 86.5 90.0 Margin dB -3.5 Polar Ant Pre-C 2 17976.380M 42.5 +45.8 -33.5 +6.4 +5.9 +0.0 67.1 90.0 -22.9 Pre-C 3 17921.280M 42.5 +45.5 -33.6 +6.4 +5.9 +0.0 66.7 90.0 -23.3 Pre-C 4 17970.480M 42.2 +45.7 -33.5 +6.4 +5.9 +0.0 66.7 90.0 -23.3 Pre-C 5 17951.780M 42.1 +45.7 -33.6 +6.4 +5.9 +0.0 66.5 90.0 -23.5 Pre-C 6 17895.700M 42.3 +45.4 -33.6 +6.4 +5.9 +0.0 66.4 90.0 -23.6 Pre-C 7 17885.860M 42.2 +45.3 -33.7 +6.4 +5.9 +0.0 66.1 90.0 -23.9 Pre-C 8 17845.510M 42.3 +45.1 -33.7 +6.4 +5.9 +0.0 66.0 90.0 -24.0 Pre-C 9 17862.240M 42.2 +45.2 -33.7 +6.4 +5.9 +0.0 66.0 90.0 -24.0 Pre-C 10 17570.980M 42.9 +43.7 -34.1 +6.3 +5.8 +0.0 64.6 90.0 -25.4 Pre-C Page 116 of 161 Report No.: MIL05-043 11 17622.140M 42.4 +43.9 -34.0 +6.3 +5.8 +0.0 64.4 90.0 -25.6 Pre-C 12 17290.540M 44.4 +41.7 -34.3 +6.2 +5.8 +0.0 63.8 90.0 -26.2 Pre-C 13 17452.900M 42.8 +42.9 -34.2 +6.3 +5.8 +0.0 63.6 90.0 -26.4 Pre-C 14 17488.320M 42.2 +43.2 -34.2 +6.3 +5.8 +0.0 63.3 90.0 -26.7 Pre-C 15 17503.080M 42.1 +43.3 -34.2 +6.3 +5.8 +0.0 63.3 90.0 -26.7 Pre-C 16 17389.920M 42.6 +42.5 -34.2 +6.3 +5.8 +0.0 63.0 90.0 -27.0 Pre-C 17 17326.940M 43.2 +42.0 -34.3 +6.2 +5.8 +0.0 62.9 90.0 -27.1 Pre-C 18 17349.580M 43.0 +42.2 -34.3 +6.2 +5.8 +0.0 62.9 90.0 -27.1 Pre-C 19 17356.460M 42.8 +42.2 -34.3 +6.2 +5.8 +0.0 62.7 90.0 -27.3 Pre-C 20 16992.980M 43.4 +39.5 -34.4 +6.1 +5.7 +0.0 60.3 90.0 -29.7 Pre-C 21 14557.540M 43.0 +40.9 -35.8 +5.8 +5.2 +0.0 59.1 90.0 -30.9 Pre-C 22 16863.850M 42.9 +38.9 -34.5 +6.1 +5.7 +0.0 59.1 90.0 -30.9 Pre-C 23 13775.760M 44.2 +39.8 -35.8 +5.7 +5.1 +0.0 59.0 90.0 -31.0 Pre-C 24 14458.450M 42.8 +41.0 -35.8 +5.8 +5.2 +0.0 59.0 90.0 -31.0 Pre-C 25 16890.880M 42.7 +39.0 -34.5 +6.1 +5.7 +0.0 59.0 90.0 -31.0 Pre-C 26 14420.410M 42.8 +40.9 -35.8 +5.8 +5.2 +0.0 58.9 90.0 -31.1 Pre-C 27 14509.500M 42.5 +41.1 -35.8 +5.8 +5.2 +0.0 58.8 90.0 -31.2 Pre-C Page 117 of 161 Report No.: MIL05-043 28 14526.510M 42.6 +41.0 -35.8 +5.8 +5.2 +0.0 58.8 90.0 -31.2 Pre-C 29 14447.430M 42.5 +41.0 -35.8 +5.8 +5.2 +0.0 58.7 90.0 -31.3 Pre-C 30 16895.880M 42.3 +39.1 -34.5 +6.1 +5.7 +0.0 58.7 90.0 -31.3 Pre-C Page 118 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear 10/20/2005 10:57:03 AM 13 A. Brar Model # SIU Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N GLAT 2508 S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 17998.630M 42.4 +45.9 -33.5 +6.4 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +5.9 +0.0 67.1 90.0 -22.9 Polar Ant Horiz 2 17771.890M 43.1 +44.7 -33.8 +6.4 +5.9 +0.0 66.3 90.0 -23.7 Horiz 3 17879.440M 42.2 +45.3 -33.7 +6.4 +5.9 +0.0 66.1 90.0 -23.9 Horiz 4 17846.560M 42.2 +45.1 -33.7 +6.4 +5.9 +0.0 65.9 90.0 -24.1 Horiz 5 17861.630M 41.9 +45.2 -33.7 +6.4 +5.9 +0.0 65.7 90.0 -24.3 Horiz 6 17591.740M 43.1 +43.8 -34.1 +6.3 +5.8 +0.0 64.9 90.0 -25.1 Horiz Page 119 of 161 Report No.: MIL05-043 7 17552.010M 42.8 +43.6 -34.1 +6.3 +5.8 +0.0 64.4 90.0 -25.6 Horiz 8 17563.650M 42.5 +43.6 -34.1 +6.3 +5.8 +0.0 64.1 90.0 -25.9 Horiz 9 17608.180M 42.1 +43.9 -34.0 +6.3 +5.8 +0.0 64.1 90.0 -25.9 Horiz 10 17618.460M 42.1 +43.9 -34.0 +6.3 +5.8 +0.0 64.1 90.0 -25.9 Horiz 11 17388.290M 43.6 +42.5 -34.2 +6.3 +5.8 +0.0 64.0 90.0 -26.0 Horiz 12 17392.400M 43.0 +42.5 -34.2 +6.3 +5.8 +0.0 63.4 90.0 -26.6 Horiz 13 17425.970M 42.7 +42.7 -34.2 +6.3 +5.8 +0.0 63.3 90.0 -26.7 Horiz 14 17301.990M 42.9 +41.8 -34.3 +6.2 +5.8 +0.0 62.4 90.0 -27.6 Horiz 15 17261.950M 43.0 +41.5 -34.3 +6.2 +5.8 +0.0 62.2 90.0 -27.8 Horiz 16 14473.160M 43.4 +41.0 -35.8 +5.8 +5.2 +0.0 59.6 90.0 -30.4 Horiz 17 16880.570M 43.0 +39.0 -34.5 +6.1 +5.7 +0.0 59.3 90.0 -30.7 Horiz 18 14458.150M 42.9 +41.0 -35.8 +5.8 +5.2 +0.0 59.1 90.0 -30.9 Horiz 19 16927.610M 42.4 +39.2 -34.5 +6.1 +5.7 +0.0 58.9 90.0 -31.1 Horiz 20 14307.000M 43.0 +40.7 -35.9 +5.8 +5.2 +0.0 58.8 90.0 -31.2 Horiz 21 13992.680M 43.9 +40.1 -36.1 +5.7 +5.1 +0.0 58.7 90.0 -31.3 Horiz 22 14110.800M 43.5 +40.3 -36.0 +5.7 +5.1 +0.0 58.6 90.0 -31.4 Horiz 23 14331.020M 42.7 +40.8 -35.9 +5.8 +5.2 +0.0 58.6 90.0 -31.4 Horiz 24 14977.670M 43.6 +39.1 -35.4 +6.0 +5.3 +0.0 58.6 90.0 -31.4 Horiz 25 14177.870M 43.2 +40.5 -36.0 +5.7 +5.1 +0.0 58.5 90.0 -31.5 Horiz 26 14283.970M 42.6 +40.7 -35.9 +5.8 +5.2 +0.0 58.4 90.0 -31.6 Horiz Page 120 of 161 Report No.: MIL05-043 27 13831.520M 43.5 +39.9 -35.9 +5.7 +5.1 +0.0 58.3 90.0 -31.7 Horiz 28 13916.610M 43.4 +40.0 -36.0 +5.7 +5.1 +0.0 58.2 90.0 -31.8 Horiz 29 14261.950M 42.5 +40.6 -35.9 +5.8 +5.2 +0.0 58.2 90.0 -31.8 Horiz 30 16752.440M 42.5 +38.5 -34.6 +6.1 +5.7 +0.0 58.2 90.0 -31.8 Horiz Page 121 of 161 Report No.: MIL05-043 Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170 Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N: Stanford Linear Accelerator Center RE102 10KHz-18GHz 83492 Radiated Scan Stanford Linear Accelerator Center Stanford Linear SIU GLAT 2508 Equipment Under Test (* = EUT): Function Stanford Linear Accelerator Center* Support Devices: Function Power Supply VME Crate Mouse Keyboard Monitor PC Date: Time: Sequence#: Tested By: Manufacturer Stanford Linear Manufacturer AEMC Instruments Dawn Dell by Microsoft Dell Dell Dell 10/20/2005 9:02:30 AM 8 A. Brar Model # SIU S/N GLAT 2508 Model # AX502 11-1011777-2119 X06-08477 04N454 MX-D9J367-47605-379-AYKJ DHM S/N PC70344 002563 none TH-04N454-37171-33F-E488 PC65341 JLJJ331 Test Conditions / Notes: Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The 10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage. Power cable is grounded to the chamber wall right before it enters the chamber. Transducer Legend: T1=Horn Antenna AN02113 SN4660 (Fremont) T3=CAB HF 72" ANP05317 Pasternack T2=HP-83017A, A/N 00785 T4=Cable AN2716 40 GHz Reading listed by margin. Measurement Data: # Freq Rdng T1 T2 T3 MHz dBµV dB dB dB 1 17981.510M 42.6 +45.8 -33.5 +6.4 Test Distance: 1 Meter T4 Dist Corr Spec Margin dB Table dBµV/m dBµV/m dB +5.9 +0.0 67.2 90.0 -22.8 Polar Ant Vert 2 17986.980M 42.2 +45.8 -33.5 +6.4 +5.9 +0.0 66.8 90.0 -23.2 Vert 3 17785.600M 42.8 +44.8 -33.8 +6.4 +5.9 +0.0 66.1 90.0 -23.9 Vert 4 17753.400M 42.7 +44.6 -33.8 +6.4 +5.9 +0.0 65.8 90.0 -24.2 Vert 5 17812.310M 42.4 +44.9 -33.8 +6.4 +5.9 +0.0 65.8 90.0 -24.2 Vert 6 17727.370M 43.0 +44.5 -33.9 +6.3 +5.8 +0.0 65.7 90.0 -24.3 Vert Page 122 of 161 Report No.: MIL05-043 7 17679.420M 43.0 +44.2 -33.9 +6.3 +5.8 +0.0 65.4 90.0 -24.6 Vert 8 17686.270M 42.7 +44.3 -33.9 +6.3 +5.8 +0.0 65.2 90.0 -24.8 Vert 9 17690.380M 42.6 +44.3 -33.9 +6.3 +5.8 +0.0 65.1 90.0 -24.9 Vert 10 17458.850M 43.7 +43.0 -34.2 +6.3 +5.8 +0.0 64.6 90.0 -25.4 Vert 11 17466.380M 43.4 +43.0 -34.2 +6.3 +5.8 +0.0 64.3 90.0 -25.7 Vert 12 17543.110M 42.4 +43.5 -34.1 +6.3 +5.8 +0.0 63.9 90.0 -26.1 Vert 13 17421.180M 43.2 +42.7 -34.2 +6.3 +5.8 +0.0 63.8 90.0 -26.2 Vert 14 17468.440M 42.8 +43.1 -34.2 +6.3 +5.8 +0.0 63.8 90.0 -26.2 Vert 15 17391.720M 43.1 +42.5 -34.2 +6.3 +5.8 +0.0 63.5 90.0 -26.5 Vert 16 17384.190M 43.1 +42.4 -34.2 +6.3 +5.8 +0.0 63.4 90.0 -26.6 Vert 17 17435.560M 42.6 +42.8 -34.2 +6.3 +5.8 +0.0 63.3 90.0 -26.7 Vert 18 17446.520M 42.4 +42.9 -34.2 +6.3 +5.8 +0.0 63.2 90.0 -26.8 Vert 19 17311.000M 42.9 +41.9 -34.3 +6.2 +5.8 +0.0 62.5 90.0 -27.5 Vert 20 17029.710M 43.6 +39.7 -34.4 +6.1 +5.7 +0.0 60.7 90.0 -29.3 Vert 21 17025.710M 43.0 +39.7 -34.4 +6.1 +5.7 +0.0 60.1 90.0 -29.9 Vert 22 14425.110M 43.7 +41.0 -35.8 +5.8 +5.2 +0.0 59.9 90.0 -30.1 Vert 23 14482.170M 43.5 +41.1 -35.8 +5.8 +5.2 +0.0 59.8 90.0 -30.2 Vert 24 14496.180M 43.4 +41.1 -35.8 +5.8 +5.2 +0.0 59.7 90.0 -30.3 Vert 25 16938.620M 43.2 +39.2 -34.5 +6.1 +5.7 +0.0 59.7 90.0 -30.3 Vert 26 17000.690M 42.8 +39.5 -34.4 +6.1 +5.7 +0.0 59.7 90.0 -30.3 Vert Page 123 of 161 Report No.: MIL05-043 27 16944.630M 43.0 +39.3 -34.5 +6.1 +5.7 +0.0 59.6 90.0 -30.4 Vert 28 16959.640M 42.9 +39.3 -34.4 +6.1 +5.7 +0.0 59.6 90.0 -30.4 Vert 29 16948.630M 42.9 +39.3 -34.5 +6.1 +5.7 +0.0 59.5 90.0 -30.5 Vert 30 16973.660M 42.6 +39.4 -34.4 +6.1 +5.7 +0.0 59.4 90.0 -30.6 Vert Page 124 of 161 Report No.: MIL05-043 CS06- Conducted Susceptibility, Spikes on Power Leads Test Equipment Equipment Manufacturer Solar Transient Pulse Generator HP Oscilloscope Solar 5 Ohms Resistor CNR = Calibration not required. Model # 8282-1 Serial # 881811 Asset # 00366 Cal Date CNR Cal Due CNR 54615B Type 7144-5.0 US35420829 CKC#1 00697 00141 8-29-03 CNR 8-29-05 CNR Test Procedure Calibration: The test Engineer connected the source’s output across a 5 ohm load and connected an oscilloscope across the load. The output level was increased until 12Vp was displayed on the Oscilloscope and the output level was recorded. Plots were captured to show the pulse time and amplitude. Test: Test Engineer connected the output of the source to the 28VDC Line and 28VDC Return within 5cm of the UUT. The Oscilloscope was also connected across the 28VDC Line and 28V DC Return. The source was powered on with the output set to calibration level and spikes were injected into the power line of the UUT. The test was performed for 5 minutes in positive polarity and then for 5 minutes in negative polarity. Page 125 of 161 Report No.: MIL05-043 CS06 Pre-Calibration CS06 Test Setup Page 126 of 161 Report No.: MIL05-043 CS06 Closeup Page 127 of 161 Report No.: MIL05-043 CS06 Rep Rate of 10pps CS06 Pulse Amplitude and Pulse Duration Page 128 of 161 Report No.: MIL05-043 CS06 +12V Pulse onto DC Line (Parallel Injection Method) CS06 -12V Pulse onto DC Line (Parallel Injection Method) Page 129 of 161 Report No.: MIL05-043 CS102 - Conducted Susceptibility, Power Leads, 10kHz to 10MHz Test Equipment Equipment Manufacturer General Radio Oscillator Techron Power Amplifier HP Oscilloscope Solar Coupling Transformer Solar RF Coupler Bird Electronics 50 ohms Load Resistor NTE Resistor Signal Generator Marconi AR AMP Current Measurement FCC Probe CNR = Calibration not required. Model # 1310-B 7570 54615B 6220-1A 7415-3 8134 .5Ohm Serial # 4004 8059 054333 US35420828 None 925134 01453 None Asset # 01730 02546 00697 481 00620 25632 None 2022D 150A100A F-35 119229/016 24830 296 00687 00894A 00731 Cal Date Cal Due CNR CNR 7/6/05 7/6/07 8/31/03 8/31/07 CNR CNR CNR CNR CNR CNR Verified before use 9/20/05 CNR 5/4/05 9/20/07 CNR 5/4/07 Test Procedure 10-150kHz Calibration: The Oscillator’s output was connected to input of the Techron DC amplifier. The amplifier’s output was connected to the primary side of the Audio Isolation Transformer. A .5 ohm resistor was connected across the secondary side of the Audio Isolation Transformer. The Oscillator was set to 10kHz and the amplitude was brought up until the spectrum analyzer showed voltage corresponding to the calibration limit. Then Test Engineer swept though the range of 10-150kHz and recorded the necessary output levels to obtain the power limit. 10-150kHz Test: The Audio Isolation Transformer was connected in series with the DC power line. A 10uF capacitor was connected across 28VDC Line and 28VDC Return. The Current measurement probe was clamped over the 28VDC Line between the UUT and the Audio Isolation Transformer. The current measurement probe was connected to the Spectrum Analyzer. The test Engineer set the frequency to 10kHz and increased the levels until the required voltage or the power limit was reached and swept though the frequency range of 10150kHz. Page 130 of 161 Report No.: MIL05-043 150kHz-10MHz Calibration: The Signal Generator’s output was connected to the input of the amplifier. The amplifier’s output was connected to a RF coupler, which had 50 ohms load across the output. A current measurement probe was clamped around the lead going from the output of the RF coupler to the 50 ohms load. The Signal Generator was set to 150kHz and the amplitude was brought up until the spectrum analyzer indicated the voltage corresponding to the calibration limit. The test Engineer swept though the range of 10 – 150kHz and recorded the necessary output levels to obtain the power limit. 150kHz - 10MHz Test: The RF coupler’s output was connected to 28VDC power Line, 5cm from the UUT. The Current measurement probe was clamped over the 28VDC Line between the UUT and the RF coupler. The current measurement probe was connected to the Spectrum Analyzer. The test Engineer set the frequency to 150kHz increasing the levels until the required voltage on the Spectrum Analyzer was indicated or the power limit was reached. Then the entire frequency range of 150kHz - 10MHz was swept. Page 131 of 161 Report No.: MIL05-043 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration #1 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration Page 132 of 161 Report No.: MIL05-043 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration Closeup CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Cal Test Equipment Page 133 of 161 Report No.: MIL05-043 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Test Setup CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Test Setup Closeup Page 134 of 161 Report No.: MIL05-043 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #2 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #3 Page 135 of 161 Report No.: MIL05-043 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #4 CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Closeup Page 136 of 161 Report No.: MIL05-043 CSCM- Conducted Susceptibility, Common Mode, 30Hz to 150MHz Test Equipment Equipment Manufacturer Techron AMP Solar Coupling Transformer Solar RF Coupler General Radio Oscillator Bird Electronics 50 ohms Load Resistor NTE Resistor Signal Generator Marconi AR AMP CNR = Calibration not required. Model # 7570 12 6220-1A 7415-3 1310-B 8134 .5Ohm Serial # 054333 None 925134 None 01453 None Asset # 2546 481 00620 1703 25632 None 2022D 150A100A 119229/016 18240 00687 1211 Cal Date Cal Due 4-7-03 4-7-05 CNR CNR CNR CNR CNR CNR CNR CNR Verified before use 9/20/05 CNR 9/20/07 CNR Test Procedure 30Hz to 150kHz 10-150kHz Calibration: The Oscillator’s output was connected to primary side of the Audio Isolation Transformer. 0.5 ohm resistor was connected across the secondary side of the Audio Isolation Transformer. The Oscillator was set to 30kHz and the amplitude was brought up until the spectrum analyzer showed voltage corresponding to the calibration limit. Then Test Engineer swept though the range of 10 - 150kHz and recorded the necessary output levels to obtain the power limit. 10-150kHz Test: The Audio Isolation Transformer was connected in series with the DC power line. 0.5 ohm resistor was added to the secondary of the audio isolation transformer to dampen the impedance per David Nelson. A 10uF capacitor was connected across the 28VDC Input Power Line and 28VDC Return Line. The current measurement probe was clamped over the 28VDC Power Line between the UUT and the Audio Isolation Transformer. The current measurement probe was connected to the Spectrum Analyzer. The frequency was set to 10kHz and the levels were increased until the required voltage or the power limit was reached. The entire frequency range of 10 - 150kHz. was swept. Page 137 of 161 Report No.: MIL05-043 Test Procedure 150kHz – 150MHz .150kHz - 150MHz Calibration: The Signal Generator’s output was connected to the input of an amplifier. The amplifier’s output was connected to RF coupler, which had a 50 ohm load across its output. The Oscilloscope was connected across the 50 ohm load measuring the voltage to obtain the 1 watt power limit. The Signal Generator was set to 150kHz and the amplitude was brought up until the Oscilloscope indicated the voltage necessary to obtain 1 watt. The test engineer swept though the frequency range of 150kHz - 150MHz recording the necessary output levels to obtain the power limit. 150kHz - 150MHz Test: The RF coupler’s output was connected to 28VDC Power Line, within 5cm from the UUT. The Oscilloscope was connected from 28VDC Power Line to Ground between the UUT and the RF coupler. The frequency was set to 150kHz and the output level was increased until the power limit (400mVpp) was reached. The entire frequency range of 150kHz - 150MHz was swept. Page 138 of 161 Report No.: MIL05-043 Conducted Susceptibility Common Mode .03 - 150kHz Pre-Cal Conducted Susceptibility Common Mode, .03 - 150kHz Test Setup Page 139 of 161 Report No.: MIL05-043 Conducted Susceptibility Common Mode, .03 - 150kHz Closeup Conducted Susceptibility Common Mode, 15 - 150MHz Pre-Cal Page 140 of 161 Report No.: MIL05-043 Conducted Susceptibility Common Mode, .15 - 150kHz Test Setup Conducted Susceptibility Common Mode, .15 - 150MHz Closeup Page 141 of 161 Report No.: MIL05-043 RS101 - Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz Test Equipment Function SA - E4446A Current Probe F-10 GR - Oscillator Tx Magnetic Loop Magnetic Loop Sensor DC Amp - 7570 Asset # 02668 02142 01703 02719 02720 02546 S/N US44300408 37 4004 - Cal Not Required 05019 05020 8059 054333 Cal Date 01/13/2005 04/23/2003 02/28/2005 08/16/2005 08/16/2005 07/06/2005 Cal Due 01/13/2007 04/23/2005 02/28/2005 08/16/2007 08/16/2007 07/06/2007 Test Procedure A calibration of the test setup was performed per the method specified in MIL-STD-461E Paragraph 5.18.3.4. The function generator was connected to the amplifier and the output of the amplifier was connected to the transmit loop. The transmit loop was placed 5cm from the front face of the UUT. The test engineer manually increased the frequency from 30Hz to 100KHz while maintaining the necessary current going into the Tx loop, which was kept 10dB higher than the required current for the limit. Current was being monitored by the current probe clamped onto one of the two leads that were going to the Tx loop. The current was being displayed on the SA. Testing was repeated on the back, right side, left side, parallel to cable and top faces of the UUT. The functionality of the UUT was monitored throughout the testing. Page 142 of 161 Report No.: MIL05-043 RS101 Radiated Susceptibility, Magnetic Field Pre-Cal RS101 Radiated Susceptibility, Magnetic Field, Pre-Cal Closeup Page 143 of 161 Report No.: MIL05-043 RS101 Radiated Susceptibility, Magnetic Field, Test Setup RS101 Radiated Susceptibility, Magnetic Field, Front Side Page 144 of 161 Report No.: MIL05-043 RS101 Radiated Susceptibility, Magnetic Field, Back Side RS101 Radiated Susceptibility, Magnetic Field, Right Side Page 145 of 161 Report No.: MIL05-043 RS101 Radiated Susceptibility, Magnetic Field, Left Side RS101 Radiated Susceptibility, Magnetic Field, Top Side Page 146 of 161 Report No.: MIL05-043 RS101 Radiated Susceptibility, Magnetic Field, Cables Page 147 of 161 Report No.: MIL05-043 RS103 - Radiated Susceptibility, Electric Field, 10kHz to 18GHz Test Equipment Equipment Signal Generator Signal Generator Function Generator Amplifier Amp (1-4GHz) Amp (4-8GHz) Amp (8-12GHz) Amp (12-18GHz) Oscilloscope Biconical Antenna DRG Antenna DRG Antenna Field Monitor Field Probe Field Probe Manufacturer Marconi HP BK Precision AR Model # 2022D 8673C 4011 30W1000M7 Serial # 119229/016 2447A00198 9902-0294 18691 Asset # 00687 02547 02237 01209 Cal Date 9/20/05 8/9/04 9/2/05 CNR Cal Due 9/20/07 8/9/06 9/2/07 CNR Ophir Hughes Hughes Hughes HP EMCO A.H. Systems EMCO AR AR AR 5162F 1277H002F000 1277H03F000 8010H04F000 54615B 3104 SAS-570 3115 FM 2000 FP 2000 FP 2080 1020 177 18 157 US35420829 2683 155 9602-4660 18327 18676 24792 02691 1461 01463 0992A 00697 00732 02525 02113 00951A 01207 00870 CNR CNR CNR CNR 8/31/03 4/11/05 6/10/05 3/8/05 3/16/05 11/12/03 6/25/04 CNR CNR CNR CNR 8/31/07 4/11/07 6/10/07 3/8/07 3/15/07 11/12/05 6/25/06 Test Procedure RS103 Test Levels and polarities: 30MHz to 18GHz – 1 V/M vertical and horizontal polarities. The output of the signal generator was connected to the amplifier. The amplifier was connected to the E/H Field antenna. The antenna was brought in and placed in front of the UUT in vertical polarization. The field probe was placed next to the UUT 30cm above the ground plane. RS103 Test Sweep: The field probe was located in front of the Tx antenna, 1kHz squarewave modulation was applied to the threat signal with a 40dB On/Off ratio and a sweep was performed. The field strength values were recorded at each frequency in the sweep from 30MHz to 18GHz at 1V/m The functionality of the UUT was monitored throughout the sweep. Antenna Polarities: For all testing , two transmit antenna polarities were used, Vertical and Horizontal. The antenna was set to horizontal polarity and the test was performed. Then the antenna was set to vertical polarity and the test was performed. There were 3 antennas used; 30-200MHz, 200-1000MHz, 1-18GHz. Page 148 of 161 Report No.: MIL05-043 30 to 200MHz Testing: The bi-conical antenna was brought in and placed 1 meter from the UUT. The sweep was performed using a 1kHz squarewave modulation. The field probe was used to measure the field strength. The UUT was monitored throughout the testing for any signs of degradation. The antenna was rotated to the vertical polarization and the sweep was repeated. 200 to 1000MHz Testing: The DRG antenna was brought in and placed 1 meter away from the UUT. The sweep was performed using a 1kHz squarewave modulation. The field probe was used to measure the field strength. The UUT was monitored throughout the testing for any signs of degradation. The antenna was rotated to the vertical polarization and the sweep was repeated. 1 to 18GHz Testing: The DRG antenna was brought in and placed 1 meter from the UUT in horizontal polarization. The field probe was placed in front of the antenna. The sweep was performed using a 1kHz squarewave modulation. The field probe was used to measure the field strength. The UUT was monitored throughout the testing for any signs of degradation. The antenna was rotated to the vertical polarization and the sweep was repeated. Page 149 of 161 Report No.: MIL05-043 Bicon Antenna, 30 - 200MHz Vertical Polarization Test Setup Page 150 of 161 Report No.: MIL05-043 Horn Antenna, 200 - 1000MHz Vertical Polarization Test Setup Horn Antenna, 200 - 1000MHz Vertical Polarization Closeup Page 151 of 161 Report No.: MIL05-043 Horn Antenna, 1 - 18GHz Horizontal Polarization Test Setup Page 152 of 161 Report No.: MIL05-043 Page 153 of 161 Report No.: MIL05-043 Page 154 of 161 Report No.: MIL05-043 TEST LOG Date 10/19/2005 Name A. Brar Time 745 800 801 815 900 905 930 945 1015 1054 1100 1110 1127 1205 1240 1335 1349 1400 1405 1430 1445 Event Preparing lab. Waiting for customer. Out schedule page isn’t working at this time, contacting William Brandle. William mentions that it should be up in 15 minutes. Page isn’t up yet. David Nelson from SLAC arrives with support equipment. We will continue with setup. UUT has not arrived yet. Schedule page is up. Generating test log. Test log is ready. Placing the 10uF caps in shielded box. Feed through caps at in a shielded box. Setup complete, unit is functioning properly. Placing foil on back side of the chamber, where the cables are entering. Resistance between the UUT and test table is 0.35milliohms and resistance between the test table and chamber wall is 0.1milliohms. Now I’m going over the test plan with David to see which test should be performed first. Setting up to perform RE102 pre-cal. Christine and I are on the conference call with Steve Behm. Fred (witness) has arrived. Continuing with RE102 pre-cal. Rod antenna pre-cal complete. While we are at it we will run the path check at 200 and 1000MHz as well. I’m borrowing the sig gen from Christine at this time and it needs to be returned soon. Path check completed at 10kHz, 15.005MHz, 30MHz, 200MHz, and 1000MHz. Path checks are within tolerance. Setting up to test from .01-30MHz. Begin testing from .01-30MHz with Rod Antenna. RE102 .01-30MHz SEQ 1 Rod Antenna Complete. Pass. Adding EUT and Support Equipment to the emissions data sheet. Begin testing from 30-200MHz. RE102 30-200MHz SEQ 2 Vert RE102 30-200MHz SEQ 3 Horiz Complete. Pass. Page 155 of 161 Report No.: MIL05-043 1450 1503 1504 1620 1643 10/20/05 A. Brar 1645 800 820 835 855 856 915 1030 1040 1148 1157 1205 Begin testing from 200-1000MHz. RE102 200-1000MHz SEQ 4 Vert RE102 200-1000MHz SEQ 5 Horiz Complete. Pass. Now setting up to perform path check at 18GHz. Due to the notches in the limit, test equipment has to be moved inside of the chamber. Setup complete. Modified the limit around the notched to perform path check at 18GHz. Pre-cal isn’t coming in, I will change the pre-amps tomorrow and continue with pre-cal. Log off. Swapping pre-amp and transducers. Begin path check sweep is 18GHz. Sweep complete. Path check is within tolerance. Setting up to perform testing. Loaded proper test equipment list into the emissions data sheets. Begin testing from 1-18GHz. RE102 1-1.55GHz Seq 6 Vert RE102 1.6-1.77GHz Seq 7 Vert RE102 2.3-18GHz Seq 8 Vert RE102 1.55-1.6GHz Seq 9 Vert 1.55-1.6GHz: RBW 3KHz, VBW 9.1KHz, Sweep Time 20s/sweep, 17 sweeps. Failing seq 9. Troubleshooting at 1.583976GHz. The emissions are coming from J7 connector. David would like to continue with testing. Continuing with testing. RE102 1.77-2.3GHz Seq 10 Vert 1.77-2.3GHz: RBW 10KHz, VBW 30KHz, Sweep Time 1s/sweep, 53 sweeps. RE102 1-1.55GHz Seq 11 Horiz RE102 1.6-1.77GHz Seq 12 Horiz RE102 2.3-18GHz Seq 13 Horiz RE102 1.77-2.3GHz Seq 14 Horiz RE102 1.55-1.6GHz Seq 15 Horiz Unit passes in horizontal polarity in the range of 1-18GHz. Begin engr run in vertical polarity. RE102 1.55-1.6GHz Seq 16 Vert Complete. Fail. Break for Lunch. Page 156 of 161 Report No.: MIL05-043 1300 1304 1335 1340 1410 1415 1445 1520 1525 1635 1640 10/21/05 A. Brar 1652 1655 800 815 820 830 845 953 958 1044 1015 1045 Back form lunch. Begin scan, lowered the RBW to 1KHz from 1.55-1.6GHz. RE102 1.55-1.6GHz Seq 17 Vert 1KHz RBW RE102 1.55-1.6GHz Seq 18 Vert 1KHz RBW RE102 1.55-1.6GHz Seq 19 Vert 1KHz RBW Seq 19 passes. Moving onto RE101. Moving and setting up outside of the chamber for RE101 pre-cal. Setup outside of the chamber. Realized that the magnetic loop is out of cal. Requested it from Mariposa, they will ship it today. I will continue with some of the CE testing for now. Setting up for CECM. David would like to leave CECM for last since we need to cut into the wires. I will setup to run CE102 pre-cal. CE102 pre-cal setup complete. Begin pre-cals at 10KHz, 2MHz & 10MHz. Complete, and it is within tolerance. Begin testing to CE102. CE102 SEQ 20 POSITIVE LEAD CE102 SEQ 21 Return LEAD Complete. Unit passes. Log off. Renaming photos. Preparing previous data for report. Determining which test to perform next. CECM seems to make better sense at this time. Randy needs to be working with S. Goulet therefore I will need to take over in chamber 3 and C. Kendall with take over SLAC. At this time Chuck is explaining the testing to Robert S. Goulet’s customer is running late. Begin testing to CECM onto DC Line & Return. Capturing each plot with different time divisions displaying the noise to be below the spec. Complete. Unit is well within tolerance, Pass. Setting up to perform RE101 path check. Begin RE101 Path Check. The SA is showing the signal at 50KHz, but the plot or data sheet show not signs of the signal existing. When the SA sweeps through the last range, we clearly see the 50KHz signal on the SA, but now on the plot or data sheet. Submitting a support request. Page 157 of 161 Report No.: MIL05-043 1100 1200 1230 1245 1300 1310 1320 1355 1422 1500 Begin CS102 10-150kHz pre cal into 0.5ohm resistor. 1530 Pre-cal complete. setting up to perform CS102 testing from 10-150kHz. Begin testing DC Line to CS102 from 10-150kHz. There is a 0.5 ohm resistor added to the output of the coupling transformer per David’s request. Complete. Pass. Begin testing DC Return to CS102 from 10-150kHz. There is a 0.5 ohm resistor added to the output of the coupling transformer per David’s request. Complete. Pass. Log off. Setting up for CS102 .15-10MHz pre-cal. Setup complete. Begin pre-cal. 1620 1630 1645 10/24/05 A. Brar On the phone with Greg, trying to resolve this problem. No luck with this SA. Noon technical meeting. Meeting complete. Lunch. Back from lunch. Unable to arrange an analyzer which will perform testing from 20Hz to 50kHz, there is one in Chamber 3 but it is being used by S. Goulet. The one that can be swapped with chamber 3’s has a broken knob. We will have to delay this test for now, that was 2 hours down the drain. I let Greg know that whenever he gets his hands on one of the PSAs, try running these sweeps with the new software. Randy calls and mentions that the SA was set to collect 8000 pts and he changed it to 1000, this should resolve the problem, I will try it again. Now it is working fine. Setting up to test from 1m test distance, locating a fixture to hold the loop. Begin testing to RE101. The model number on the emissions data sheets was listed wrong so far, I corrected it now, it will be correct from now on. RE101 SEQ 22 BACK SIDE – CONNECTORS RE101 SEQ 23 LEFT SIDE RE101 SEQ 24 FRONT SIDE RE101 SEQ 25 RIGHT SIDE RE101 SEQ 26 TOP SIDE Complete. Unit passes. Setting up to perform CS102 precal from 10-150kHz. 1655 1700 800 900 Page 158 of 161 Report No.: MIL05-043 920 930 1013 1029 1035 1050 1105 1130 1150 1219 1220 1245 1330 1345 1405 1410 1425 1440 1445 1500 1512 1520 1542 1626 10/25/05 A. Brar 1656 1700 815 818 846 Pre-cal complete. Setting up to perform testing. Realized that the UUT’s cable isn’t cut long enough for us to be able to tap into it 5cm from the UUT. David is making it longer. Begin testing from .15 to 10MHz to CS102. Complete. Pass. Setting up and discussing CSCM. We will start of with .15 to 150MHz range. Begin CSCM pre-cal from .15-150MHz. Pre cal complete. Begin testing to CSCM from .15-150MHz. Complete. Pass. Lunch. Back from lunch. Continuing with CSCM pre-cal for lower frequency range. Pre-cal procedure seems to be wrong, I will follow the limit specified in MIL STD 461 E. Chuck isn’t’ available at this time to discuss the procedure. CSCM .03-150kHz setup complete. Begin testing from .03150kHz. Complete. Pass. Setting up to perform CS02 pre-cal. Begin CS02 pre-cal. Pre-cal complete. Setting up to perform CS02 testing. Chuck called regarding CSCM from .03-150kHz, and mentioned that the pre cal is just to confirm that the wave is sinusoidal at 30Hz when the amplitude is 19.9Vp-p. Begin testing to CS02. Testing at +/-12V parallel injection method. 5 minutes at each polarity, applying 10pps. Complete. Pass. Setting up to perform RS103. Cleaned out the chamber for the low frequency antenna. Begin testing to RS103 from 30-200MHz in Vertical. Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds. Test complete up to 200MHz. Unit passes. Log off. I was running late due to traffic. Begin testing to RS103 from 30-200MHz in Horizontal. Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds. Complete. Pass. Page 159 of 161 Report No.: MIL05-043 855 918 920 945 950 1025 1045 1110 1300 1345 1422 1618 1623 10/26/05 A. Brar 1650 1655 1657 1700 800 810 819 931 935 Begin testing to RS103 from 200-1000MHz in Vertical. Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds. Complete. Pass. Begin testing to RS103 from 200-1000MHz in Horizontal. Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds. Complete. Pass. Administrative work, catching up with equipment list and so on. Added test equipment list, needs to be updated as far as cal dates. Now continuing with 1-18GHz RS103 setup. HF Sig Gen isn’t available yet, Robert needs it for about an hour. I requested the customer to take longer lunch and by the time he gets back we will have the sig gen. Updating equipment list. Equipment list updated. Robert mentions that he should be done by 1330 with the HF Sig Gen. Robert is done with the equipment. I’m moving it over to MIL Chamber and setting it up. Begin testing to RS103 from 1-18GHz in Horizontal. Using 1kHz 50% duty cycle PM. Dwell time is 1 seconds. Complete. Pass. Begin testing to RS103 from 1-4GHz in Vertical. Using 1kHz 50% duty cycle PM. Dwell time is 1 seconds. Complete. Pass. David is shutting down the unit. Completing work order back with today’s changes. Log off. Booting up equipment. Waiting for the UUT to be ready. Begin testing to RS103 from 4-18GHz in Vertical. Using 1kHz 50% duty cycle PM. Dwell time is 1 seconds. Complete. Pass. RS103 testing has been completed from 30MHz to 18GHz and the unit passes in this range at 1V/m level. The TP stated start frequency to be 14kHz, but per David Nelson and according to previous testing we ended up starting off at 30MHz. Tearing down RS103 setup to start off with RS101 pre-cal. Page 160 of 161 Report No.: MIL05-043 1030 Setup for RS101 pre-cal complete. Not calculating the numbers. 1100 1113 1145 Begin RS101 pre-cal. 1220 1225 1432 1435 Pre-cal complete, the final result Begin testing to RS101. Testing cables, back side, right side, front side, left side and top side. RS101 complete. Unit Passes. All testing per the test procedure has been completed and the unit has met all of the requirements per the procedure. All data has been updated and it is ready to be uploaded. Log off. Page 161 of 161 Report No.: MIL05-043