electromagnetic interference test report

Transcription

electromagnetic interference test report
ELECTROMAGNETIC INTERFERENCE TEST REPORT
FOR THE STANFORD LINEAR ACCELERATOR CENTER
SPACECRAFT INTERFACE UNIT (SIU), LAT-DS-01862
MIL-STD-461E (1999), SECTIONS CE102, RE101, RE102, RS101 AND RS103
MIL-STD-462 SECTIONS: CS102 (NOTICE 5 1986) AND CS06 (NOTICE 3 1971)
TESTING IN ACCORDANCE WITH TEST PLAN TP05-83492-1
DATE OF ISSUE: NOVEMBER 3, 2005
PREPARED FOR:
PREPARED BY:
Stanford Linear Accelerator Center
2575 Sand Hill Road MS: 96
Menlo Park, CA 94025
Valerie Honsinger
CKC Laboratories, Inc.
5046 Sierra Pines Drive
Mariposa, CA 95338
P.O. No.: 0000056078
W.O. No.: 83492
Date of test: October 19 - 26, 2005
Report No.: MIL05-043
This report contains a total of 161 pages and may be reproduced in full only. Partial reproduction may only be done
with the written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, as
identified herein.
Page 1 of 161
Report No.: MIL05-043
TABLE OF CONTENTS
Administrative Information .............................................................................................3
Approvals.........................................................................................................................4
Unit Under Test (UUT) Description ................................................................................5
Unit Under Test ...............................................................................................................5
Peripheral Devices ...........................................................................................................5
Summary of Results.........................................................................................................6
Report of Measurements ..................................................................................................8
CE102 - Conducted Emissions, Power Leads, 10kHz to 10MHz........................8
CECM – Conducted Emissions, Common Mode, DC to 150MHz .....................26
RE101 - Radiated Emissions, Magnetic Field, 30Hz to 100kHz.........................36
RE102 - Radiated Emissions, Electric Field, 10kHz to 18GHz ..........................56
CS06 - Conducted Susceptibility, Spikes on Power Leads .................................125
CS102 - Conducted Susceptibility, Power Leads, 10kHz to 10MHz ..................130
CSCM - Conducted Susceptibility, Common Mode, 30Hz to 150MHz..............137
RS101 - Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz ...................142
RS103 - Radiated Susceptibility, Electric Field, 10kHz to 18GHz .....................148
Test Log ...........................................................................................................................155
Page 2 of 161
Report No.: MIL05-043
ADMINISTRATIVE INFORMATION
SCOPE:
To demonstrate testing of the Spacecraft Interface Unit (SIU), LAT-DS-01862 with the
requirements for MIL-STD-461E and MIL-STD-462D in accordance with test plan TP05-834921.
CONTRACT NUMBERS:
NA
APPLICABLE DOCUMENTS:
1. MIL-STD-461E - Electromagnetic Emission and Susceptibility Requirements for the Control
of Electromagnetic Interference
2. MIL-STD-462E - .Measurements of Electromagnetic Interference Characteristics
3. MIL-STD-464A – Electromagnetic Environmental Effects Requirements for Systems
4. 433-RQMT-0005, Rev A – GLAST Observatory Electromagnetic Interference (EMI)
Requirements Document, NASA/GSFC, Oct 6, 2003
5. MIL-STD-45662 Calibration Systems Requirements
6. LAT-MD-00408 - “LAT Instrument Performance Verification Plan”, SLAC
7. LAT-SS-00778 – LAT Environmental Specification, SLAC, M. Nordby
8. CKC Test Procedure: TP05-83492-1
MANUFACTURER:
Stanford Linear Accelerator Center
2575 Sand Hill Road MS: 96
Menlo Park, CA 94025
REPRESENTATIVE:
Dave Nelson
TEST LOCATION:
CKC Laboratories, Inc.
1120 Fulton Place
Fremont, CA 94539
Page 3 of 161
Report No.: MIL05-043
FREMONT, CA MILITARY CHAMBER
The CKC Laboratories, Inc. Fremont EMI Chamber used for the testing was a 16' x 16' x 10'
high shielded enclosure designed to attenuate radio frequency noise over 80 dB up to 1GHz, and
over 60 dB at 18GHz. The enclosure uses ferrite tiles with foam anechoic material in key areas
to achieve uniform testing from 1MHz to 40GHz. Power brought into the room is filtered over
100 dB for frequencies over 14kHz. All emissions measurement equipment is operated from
isolation transformers, which help eliminate the possibility of ground loops. All lighting in the
laboratory is filtered to reduce electrical noise. In addition, incandescent lights are used during
emissions testing to further reduce the potential for electrical noise. The ground plane in the
chamber consists of a 3'3” x 12' x 0.020" thick copper sheet bonded to the shield room wall with
0.1 mW of bonding resistance.
APPROVALS
QUALITY ASSURANCE:
TEST PERSONNEL:
Steve Behm, Director of Engineering Services
Amrinder Brar, Lab Manager
Joyce Walker, Quality Assurance Administrative
Manager
Page 4 of 161
Report No.: MIL05-043
UNIT UNDER TEST (UUT) DESCRIPTION
UNIT UNDER TEST
Spacecraft Interface Unit (SIU)
Manuf:
Stanford Linear
Model:
LAT-DS-01862
Serial:
GLAT 2508
PERIPHERAL DEVICES
The UUT was tested with the following peripheral device(s):
Power Supply
Manuf:
AEMC Instruments
Model:
AX502
Serial:
PC70344
VME Crate
Manuf:
Dawn
Model:
11-1011777-2119
Serial:
002563
Mouse
Manuf:
Model:
Serial:
Dell by Microsoft
X06-08477
NA
Keyboard
Manuf:
Model:
Serial:
Dell
04N454
TH-04N454-37171-33F-E488
Monitor
Manuf:
Model:
Serial:
Dell
MX-D9J367-47605-379-AYKJ
PC65341
PC
Manuf:
Model:
Serial:
Dell
DHM
JLJJ331
Page 5 of 161
Report No.: MIL05-043
SUMMARY OF RESULTS
As received, the Stanford Linear Accelerator Center Spacecraft Interface Unit (SIU), LAT-DS01862 was tested to following standards and specifications:
Test Description
CE102 - Conducted
Emissions, Power
Leads, 10kHz to
10MHz
CECM - Conducted
Emissions,
Common Mode,
DC to 150 MHz
RE101 – Radiated
Emissions, 20Hz to
50kHz
RE102 - Radiated
Emissions, 10kHz
to 18GHz
CS06 – Conducted
Susceptibility,
Spikes on Power
Leads
CS102 – Conducted
Susceptibility,
Power Leads,
10kHz to 10MHz
CSCM –
Conducted
Susceptibility,
Common Mode,
30Hz to 150MHz
Results
Outcome
No emissions exceeding the limit were observed from
PASS
10kHz to 10MHz on the 28VDC Input Power Lead and
on the 28VDC Return Lead with input power set to
28VDC.
No emissions exceeding the limit were observed on the
PASS
28VDC Input Power Lead and on the 28VDC Return
Lead to 150MHz.
No out of spec emissions were observed exceeding the
7cm and 50cm limits from 30Hz to 100kHz on the Back
connectors, Left, Front, Right and Top sides of the
UUT.
The UUT exhibited no out of spec emissions from
10kHz to 30MHz in Vertical polarization and from
30MHz to 18GHz in Vertical and Horizontal antenna
polarizations.
The UUT exhibited no signs of susceptibility during the
extent of the testing on the 28VDC Input Power Line,
the 28VDC Return Line.
PASS
The UUT exhibited no signs of susceptibility during the
extent of the testing from 10kHz to 10MHz on the
28VDC Power and 28VDC Return Lines.
PASS
The UUT exhibited no signs of susceptibility during the
extent of the testing from 30Hz to 150MHz on the
28VDC Input Power Line, the 28VDC Return Line.
PASS
PASS
PASS
Page 6 of 161
Report No.: MIL05-043
Test Description
RS101 - Radiated
Susceptibility,
Magnetic Field,
20Hz to 50kHz
RS103 – Radiated
Susceptibility,
Electric Field,
10kHz to 18GHz
Results
Outcome
The UUT showed no signs of susceptibility during the
PASS
extent of the testing from 30Hz to 50kHz on the front,
back, right side, left side and top faces of the UUT at
test levels exceeding the levels specified in Figure
RS101-2.
The UUT showed no signs of susceptibility during the
PASS
extent of the testing at 1V/m from 30MHz to 18GHz in
horizontal and vertical antenna polarizations.
Page 7 of 161
Report No.: MIL05-043
REPORT OF MEASUREMENTS
CE102 - Conducted Emissions, Power Leads, 10kHz to 10MHz
Test Equipment
Function
SA - E4446A
Cable
Cable RG214/U
Andrew Cable
Current Probe F-35
Oscilloscope
Asset #
02668
P05309
02410
1184
00731
00697
S/N
US44300408
None
None
CNT-195
296
US35420829
Cal Date
01/13/2005
08/01/2005
06/07/2004
01/03/2005
05/07/2003
08/31/2005
Cal Due
01/13/2007
08/01/2007
06/07/2006
01/03/2007
05/07/2005
08/31/2007
Test Procedure
The signal generator was connected to the input of the LISN. The signal was injected a signal at
10kHz at 6dB below the limit line and the LISN output was measured on the oscilloscope. The
check was repeated at 100kHz, 2MHz and 10MHz. The check was also repeated on all
remaining LISNs.
The UUT was powered up in standard operating mode. A test cable was connected from the
monitor port on the 28VDC Input Power LISN through 20dB of attenuation to the measurement
system. A 50Ω termination was placed on the monitor port of the other LISNs. The emissions
were measured from 10kHz to 10MHz. Then, the test cable was moved to the 28VDC Return
LISN and the 50Ω termination was placed on the other LISN monitor ports. The emissions were
measured from 10kHz to 10MHz.
Page 8 of 161
Report No.: MIL05-043
CE102 Conducted Emissions, Power Leads Pre-Calibration
CE102 Conducted Emissions, Power Leads Test Setup
Page 9 of 161
Report No.: MIL05-043
CE102 Conducted Emissions, Power Leads Closeup
Seq. #
0
0
0
20
Test Description
Conducted Emissions
Conducted Emissions
Conducted Emissions
Conducted Emissions
21
Conducted Emissions
Test Lead / Conditions
Pre-Cal @ 10kHz
Pre-Cal @ 2MHz
Pre-Cal @ 10MHz
Positive Lead / Grounded to copper table as it exits cage
and chamber wall before coming into chamber.
Return Lead / Grounded to copper table as it exits cage
and chamber wall before coming into chamber.
Page 10 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
CE102 MIL-STD-462
83492
Conducted Emissions
Spacecraft Interface Unit
Stanford Linear
Stanford Linear Accelerator Center
GLAT 2508
Equipment Under Test (* = EUT):
Function
Manufacturer
Spacecraft Interface Unit* Stanford Linear
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
10/20/2005
3:58:36 PM
0
A. Brar
28V DC
Model #
Stanford Linear Accelerator Center
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Pre-Cal Sweep. Signal at 10KHz. Injecting current which is 6dB below the limit though a 50 ohms load, and
expecting to see -6dB +/-3dB from the limit.
Transducer Legend:
T1=Cable 2410
T3=CMP F-35 SN 296
T2=Cable P05309
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
10.000k
46.9
+0.1
-0.1 +10.9
dB
Dist
Table
+0.0
Test Lead:
Corr
dBµV
57.8
Pre-Cal
Spec
Margin
dBµV
dB
66.0
-8.2
Polar
Ant
Pre-C
2
40.780k
20.6
+0.1
+0.0
+3.4
+0.0
24.1
66.0
-41.9
Pre-C
3
12.429k
8.9
+0.1
-0.1
+9.6
+0.0
18.5
66.0
-47.5
Pre-C
4
13.239k
8.2
+0.1
-0.1
+9.2
+0.0
17.4
66.0
-48.6
Pre-C
5
14.049k
7.0
+0.1
-0.1
+8.8
+0.0
15.8
66.0
-50.2
Pre-C
Page 11 of 161
Report No.: MIL05-043
6
14.499k
6.9
+0.1
+0.0
+8.6
+0.0
15.6
66.0
-50.4
Pre-C
7
14.229k
6.3
+0.1
+0.0
+8.8
+0.0
15.2
66.0
-50.8
Pre-C
8
19.989k
7.9
+0.1
+0.0
+6.7
+0.0
14.7
66.0
-51.3
Pre-C
9
17.019k
5.4
+0.1
+0.0
+7.7
+0.0
13.2
66.0
-52.8
Pre-C
10
18.099k
5.8
+0.1
+0.0
+7.3
+0.0
13.2
66.0
-52.8
Pre-C
11
20.799k
6.1
+0.1
+0.0
+6.5
+0.0
12.7
66.0
-53.3
Pre-C
12
21.339k
5.4
+0.1
+0.0
+6.4
+0.0
11.9
66.0
-54.1
Pre-C
13
22.239k
5.6
+0.1
+0.0
+6.2
+0.0
11.9
66.0
-54.1
Pre-C
14
29.709k
4.8
+0.1
+0.0
+4.7
+0.0
9.6
66.0
-56.4
Pre-C
15
25.299k
3.6
+0.1
+0.0
+5.5
+0.0
9.2
66.0
-56.8
Pre-C
16
26.289k
3.3
+0.1
+0.0
+5.3
+0.0
8.7
66.0
-57.3
Pre-C
17
32.230k
4.2
+0.1
+0.0
+4.3
+0.0
8.6
66.0
-57.4
Pre-C
18
27.369k
2.5
+0.1
+0.0
+5.1
+0.0
7.7
66.0
-58.3
Pre-C
19
33.040k
3.2
+0.1
+0.0
+4.2
+0.0
7.5
66.0
-58.5
Pre-C
20
34.660k
3.3
+0.1
+0.0
+4.0
+0.0
7.4
66.0
-58.6
Pre-C
21
35.290k
2.8
+0.1
+0.0
+4.0
+0.0
6.9
66.0
-59.1
Pre-C
22
47.080k
3.5
+0.1
+0.1
+3.1
+0.0
6.8
66.0
-59.2
Pre-C
23
44.560k
3.3
+0.1
+0.0
+3.2
+0.0
6.6
66.0
-59.4
Pre-C
24
45.010k
2.9
+0.1
+0.1
+3.2
+0.0
6.3
66.0
-59.7
Pre-C
25
34.030k
1.9
+0.1
+0.0
+4.1
+0.0
6.1
66.0
-59.9
Pre-C
26
36.010k
2.0
+0.1
+0.0
+3.9
+0.0
6.0
66.0
-60.0
Pre-C
Page 12 of 161
Report No.: MIL05-043
27
43.840k
2.6
+0.1
+0.0
+3.3
+0.0
6.0
66.0
-60.0
Pre-C
28
32.680k
1.2
+0.1
+0.0
+4.3
+0.0
5.6
66.0
-60.4
Pre-C
29
47.800k
2.3
+0.1
+0.1
+3.0
+0.0
5.5
66.0
-60.5
Pre-C
30
49.420k
2.2
+0.1
+0.1
+2.9
+0.0
5.3
66.0
-60.7
Pre-C
Page 13 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
CE102 MIL-STD-462
83492
Conducted Emissions
Spacecraft Interface Unit
Stanford Linear
Stanford Linear Accelerator Center
GLAT 2508
Equipment Under Test (* = EUT):
Function
Manufacturer
Spacecraft Interface Unit* Stanford Linear
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
10/20/2005
4:27:49 PM
0
A. Brar
28V DC
Model #
Stanford Linear Accelerator Center
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Pre-Cal Sweep. Signal at 2MHz. Injecting current which is 6dB below the limit though a 50 ohms load, and
expecting to see -6dB +/-3dB from the limit.
Transducer Legend:
T1=Cable 2410
T3=4' Cable AN 01184
T2=Cable P05309
T4=CMP F-35 SN 296
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
1.996M
97.4
+0.1
+0.0
+0.0
T4
Dist
dB
Table
+1.2 +0.0
Test Lead:
Corr
dBµV
98.7
Pre-Cal
Spec
Margin
dBµV
dB
105.0
-6.3
Polar
Ant
Pre-C
2
5.988M
54.5
+0.1
+0.0
+0.0
+1.0
+0.0
55.6
85.1
-29.5
Pre-C
3
7.983M
47.2
+0.2
+0.1
+0.0
+1.0
+0.0
48.5
82.3
-33.8
Pre-C
4
9.985M
43.6
+0.2
+0.1
+0.0
+1.0
+0.0
44.9
80.0
-35.1
Pre-C
5
40.060k
24.6
+0.1
+0.0
+0.0
+3.5
+0.0
28.2
66.0
-37.8
Pre-C
Page 14 of 161
Report No.: MIL05-043
6
80.111k
23.2
+0.0
+0.0
+0.1
+2.2
+0.0
25.5
66.0
-40.5
Pre-C
7
3.992M
49.1
+0.2
+0.0
+0.1
+1.1
+0.0
50.5
92.0
-41.5
Pre-C
8
39.340k
19.9
+0.1
+0.0
+0.0
+3.6
+0.0
23.6
66.0
-42.4
Pre-C
9
10.899k
13.1
+0.1
-0.1
+0.0
+10.4
+0.0
23.5
66.0
-42.5
Pre-C
10
12.249k
13.1
+0.1
-0.1
+0.0
+9.7
+0.0
22.8
66.0
-43.2
Pre-C
11
64.360k
19.5
+0.0
+0.0
+0.0
+2.5
+0.0
22.0
66.0
-44.0
Pre-C
12
69.580k
19.5
+0.1
+0.0
+0.0
+2.4
+0.0
22.0
66.0
-44.0
Pre-C
13
18.189k
14.5
+0.1
+0.0
+0.0
+7.3
+0.0
21.9
66.0
-44.1
Pre-C
14
24.489k
15.9
+0.1
+0.0
+0.0
+5.7
+0.0
21.7
66.0
-44.3
Pre-C
15
13.509k
12.5
+0.1
-0.1
+0.0
+9.1
+0.0
21.6
66.0
-44.4
Pre-C
16
53.110k
18.6
+0.1
+0.1
+0.0
+2.8
+0.0
21.6
66.0
-44.4
Pre-C
17
14.769k
12.9
+0.1
+0.0
+0.0
+8.5
+0.0
21.5
66.0
-44.5
Pre-C
18
32.680k
16.9
+0.1
+0.0
+0.0
+4.3
+0.0
21.3
66.0
-44.7
Pre-C
19
76.150k
18.9
+0.0
+0.0
+0.1
+2.3
+0.0
21.3
66.0
-44.7
Pre-C
20
13.779k
12.2
+0.1
-0.1
+0.0
+9.0
+0.0
21.2
66.0
-44.8
Pre-C
21
15.669k
12.8
+0.1
+0.0
+0.0
+8.2
+0.0
21.1
66.0
-44.9
Pre-C
22
24.039k
15.3
+0.1
+0.0
+0.0
+5.7
+0.0
21.1
66.0
-44.9
Pre-C
23
85.511k
18.8
+0.1
+0.0
+0.0
+2.1
+0.0
21.0
66.0
-45.0
Pre-C
24
20.349k
14.2
+0.1
+0.0
+0.0
+6.6
+0.0
20.9
66.0
-45.1
Pre-C
25
59.410k
17.9
+0.0
+0.0
+0.0
+2.6
+0.0
20.5
66.0
-45.5
Pre-C
26
87.761k
18.1
+0.1
+0.0
+0.0
+2.1
+0.0
20.3
66.0
-45.7
Pre-C
Page 15 of 161
Report No.: MIL05-043
27
72.550k
17.8
+0.1
+0.0
+0.0
+2.3
+0.0
20.2
66.0
-45.8
Pre-C
28
83.891k
17.9
+0.0
+0.0
+0.1
+2.2
+0.0
20.2
66.0
-45.8
Pre-C
29
88.661k
18.0
+0.1
+0.0
+0.0
+2.1
+0.0
20.2
66.0
-45.8
Pre-C
30
45.280k
16.7
+0.1
+0.1
+0.0
+3.2
+0.0
20.1
66.0
-45.9
Pre-C
Page 16 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
CE102 MIL-STD-462
83492
Conducted Emissions
Spacecraft Interface Unit
Stanford Linear
Stanford Linear Accelerator Center
GLAT 2508
Equipment Under Test (* = EUT):
Function
Manufacturer
Spacecraft Interface Unit* Stanford Linear
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
10/20/2005
4:34:28 PM
0
A. Brar
28V DC
Model #
Stanford Linear Accelerator Center
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Pre-Cal Sweep. Signal at 10MHz. Injecting current which is 6dB below the limit though a 50 ohms load, and
expecting to see -6dB +/-3dB from the limit.
Transducer Legend:
T1=Cable 2410
T3=CMP F-35 SN 296
T2=Cable P05309
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
9.903M
73.2
+0.2
+0.1
+1.0
dB
Dist
Table
+0.0
Test Lead:
Corr
dBµV
74.5
Pre-Cal
Spec
Margin
dBµV
dB
80.1
-5.6
Polar
Ant
Pre-C
2
40.330k
20.4
+0.1
+0.0
+3.5
+0.0
24.0
66.0
-42.0
Pre-C
3
10.539k
8.7
+0.1
-0.1
+10.6
+0.0
19.3
66.0
-46.7
Pre-C
4
11.169k
7.0
+0.1
-0.1
+10.2
+0.0
17.2
66.0
-48.8
Pre-C
5
10.989k
6.6
+0.1
-0.1
+10.3
+0.0
16.9
66.0
-49.1
Pre-C
Page 17 of 161
Report No.: MIL05-043
6
12.159k
7.1
+0.1
-0.1
+9.7
+0.0
16.8
66.0
-49.2
Pre-C
7
12.879k
7.2
+0.1
-0.1
+9.4
+0.0
16.6
66.0
-49.4
Pre-C
8
13.149k
7.4
+0.1
-0.1
+9.2
+0.0
16.6
66.0
-49.4
Pre-C
9
15.489k
7.6
+0.1
+0.0
+8.2
+0.0
15.9
66.0
-50.1
Pre-C
10
15.849k
7.7
+0.1
+0.0
+8.1
+0.0
15.9
66.0
-50.1
Pre-C
11
15.039k
6.5
+0.1
+0.0
+8.4
+0.0
15.0
66.0
-51.0
Pre-C
12
16.209k
6.0
+0.1
+0.0
+8.0
+0.0
14.1
66.0
-51.9
Pre-C
13
17.469k
6.1
+0.1
+0.0
+7.5
+0.0
13.7
66.0
-52.3
Pre-C
14
18.369k
6.3
+0.1
+0.0
+7.2
+0.0
13.6
66.0
-52.4
Pre-C
15
20.619k
6.0
+0.1
+0.0
+6.5
+0.0
12.6
66.0
-53.4
Pre-C
16
22.509k
6.4
+0.1
+0.0
+6.1
+0.0
12.6
66.0
-53.4
Pre-C
17
21.789k
5.2
+0.1
+0.0
+6.3
+0.0
11.6
66.0
-54.4
Pre-C
18
23.769k
5.7
+0.1
+0.0
+5.8
+0.0
11.6
66.0
-54.4
Pre-C
19
25.839k
5.5
+0.1
+0.0
+5.4
+0.0
11.0
66.0
-55.0
Pre-C
20
25.209k
4.3
+0.1
+0.0
+5.5
+0.0
9.9
66.0
-56.1
Pre-C
21
24.669k
4.0
+0.1
+0.0
+5.6
+0.0
9.7
66.0
-56.3
Pre-C
22
33.670k
5.2
+0.1
+0.0
+4.2
+0.0
9.5
66.0
-56.5
Pre-C
23
26.289k
3.4
+0.1
+0.0
+5.3
+0.0
8.8
66.0
-57.2
Pre-C
24
38.080k
4.5
+0.1
+0.0
+3.7
+0.0
8.3
66.0
-57.7
Pre-C
25
30.249k
3.4
+0.1
+0.0
+4.6
+0.0
8.1
66.0
-57.9
Pre-C
26
36.100k
2.9
+0.1
+0.0
+3.9
+0.0
6.9
66.0
-59.1
Pre-C
Page 18 of 161
Report No.: MIL05-043
27
48.250k
3.7
+0.1
+0.1
+3.0
+0.0
6.9
66.0
-59.1
Pre-C
28
31.959k
1.8
+0.1
+0.0
+4.4
+0.0
6.3
66.0
-59.7
Pre-C
29
32.770k
1.9
+0.1
+0.0
+4.3
+0.0
6.3
66.0
-59.7
Pre-C
30
45.370k
2.0
+0.1
+0.1
+3.2
+0.0
5.4
66.0
-60.6
Pre-C
Page 19 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
CE102 MIL-STD-462
83492
Conducted Emissions
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/20/2005
4:42:12 PM
20
A. Brar
28V DC
Model #
SIU
S/N
GLAT 2508
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Cable 2410
T3=CMP F-35 SN 296
T2=Cable P05309
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
12.339k
52.8
+0.1
-0.1
+9.6
dB
Dist
Table
+0.0
Test Lead: Positive
Corr
Spec
Margin
dBµV
dBµV
dB
62.4
66.0
-3.6
Polar
Ant
Posit
2
14.229k
52.2
+0.1
+0.0
+8.8
+0.0
61.1
66.0
-4.9
Posit
3
10.629k
50.5
+0.1
-0.1
+10.5
+0.0
61.0
66.0
-5.0
Posit
4
17.829k
51.7
+0.1
+0.0
+7.4
+0.0
59.2
66.0
-6.8
Posit
5
19.719k
49.5
+0.1
+0.0
+6.8
+0.0
56.4
66.0
-9.6
Posit
Page 20 of 161
Report No.: MIL05-043
6
23.319k
46.9
+0.1
+0.0
+5.9
+0.0
52.9
66.0
-13.1
Posit
7
21.429k
43.3
+0.1
+0.0
+6.3
+0.0
49.7
66.0
-16.3
Posit
8
95.231k
46.9
+0.0
+0.0
+2.0
+0.0
48.9
66.0
-17.1
Posit
9
26.919k
43.0
+0.1
+0.0
+5.2
+0.0
48.3
66.0
-17.7
Posit
10
25.029k
37.4
+0.1
+0.0
+5.5
+0.0
43.0
66.0
-23.0
Posit
11
46.360k
38.7
+0.1
+0.1
+3.1
+0.0
42.0
66.0
-24.0
Posit
12
28.629k
34.1
+0.1
+0.0
+4.8
+0.0
39.0
66.0
-27.0
Posit
13
30.519k
34.4
+0.1
+0.0
+4.5
+0.0
39.0
66.0
-27.0
Posit
14
97.031k
36.8
+0.0
+0.0
+2.0
+0.0
38.8
66.0
-27.2
Posit
15
93.431k
33.9
+0.1
+0.0
+2.0
+0.0
36.0
66.0
-30.0
Posit
16
10.359k
25.0
+0.1
-0.1
+10.7
+0.0
35.7
66.0
-30.3
Posit
17
67.780k
30.8
+0.1
+0.0
+2.4
+0.0
33.3
66.0
-32.7
Posit
18
13.239k
23.2
+0.1
-0.1
+9.2
+0.0
32.4
66.0
-33.6
Posit
19
32.230k
27.8
+0.1
+0.0
+4.3
+0.0
32.2
66.0
-33.8
Posit
20
16.389k
24.1
+0.1
+0.0
+7.9
+0.0
32.1
66.0
-33.9
Posit
21
49.150k
29.0
+0.1
+0.1
+2.9
+0.0
32.1
66.0
-33.9
Posit
22
19.899k
25.2
+0.1
+0.0
+6.7
+0.0
32.0
66.0
-34.0
Posit
23
20.349k
25.2
+0.1
+0.0
+6.6
+0.0
31.9
66.0
-34.1
Posit
24
21.069k
24.0
+0.1
+0.0
+6.4
+0.0
30.5
66.0
-35.5
Posit
25
16.659k
22.0
+0.1
+0.0
+7.8
+0.0
29.9
66.0
-36.1
Posit
26
24.399k
24.1
+0.1
+0.0
+5.7
+0.0
29.9
66.0
-36.1
Posit
Page 21 of 161
Report No.: MIL05-043
27
18.099k
22.4
+0.1
+0.0
+7.3
+0.0
29.8
66.0
-36.2
Posit
28
20.169k
23.0
+0.1
+0.0
+6.7
+0.0
29.8
66.0
-36.2
Posit
29
42.940k
25.4
+0.1
+0.0
+3.3
+0.0
28.8
66.0
-37.2
Posit
30
50.230k
25.4
+0.1
+0.1
+2.9
+0.0
28.5
66.0
-37.5
Posit
Page 22 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
CE102 MIL-STD-462
83492
Conducted Emissions
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Manufacturer
Stanford Linear Accelerator Center* Stanford Linear
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
10/20/2005
4:46:35 PM
21
A. Brar
28V DC
Model #
SIU
S/N
GLAT 2508
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Cable 2410
T3=CMP F-35 SN 296
T2=Cable P05309
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
10.179k
52.3
+0.1
-0.1 +10.8
dB
Dist
Table
+0.0
Test Lead:
Corr
dBµV
63.1
DC Return
Spec
Margin
dBµV
dB
66.0
-2.9
Polar
Ant
DC Re
2
13.419k
52.9
+0.1
-0.1
+9.1
+0.0
62.0
66.0
-4.0
DC Re
3
15.489k
52.2
+0.1
+0.0
+8.2
+0.0
60.5
66.0
-5.5
DC Re
4
17.289k
52.1
+0.1
+0.0
+7.6
+0.0
59.8
66.0
-6.2
DC Re
5
11.889k
49.6
+0.1
-0.1
+9.9
+0.0
59.5
66.0
-6.5
DC Re
6
19.089k
48.4
+0.1
+0.0
+7.0
+0.0
55.5
66.0
-10.5
DC Re
Page 23 of 161
Report No.: MIL05-043
7
20.979k
48.1
+0.1
+0.0
+6.5
+0.0
54.7
66.0
-11.3
DC Re
8
95.681k
43.6
+0.0
+0.0
+2.0
+0.0
45.6
66.0
-20.4
DC Re
9
22.689k
38.5
+0.1
+0.0
+6.0
+0.0
44.6
66.0
-21.4
DC Re
10
26.289k
38.1
+0.1
+0.0
+5.3
+0.0
43.5
66.0
-22.5
DC Re
11
28.179k
38.4
+0.1
+0.0
+4.9
+0.0
43.4
66.0
-22.6
DC Re
12
94.691k
40.7
+0.1
+0.0
+2.0
+0.0
42.8
66.0
-23.2
DC Re
13
46.090k
38.7
+0.1
+0.1
+3.1
+0.0
42.0
66.0
-24.0
DC Re
14
31.779k
33.4
+0.1
+0.0
+4.4
+0.0
37.9
66.0
-28.1
DC Re
15
47.440k
34.5
+0.1
+0.1
+3.0
+0.0
37.7
66.0
-28.3
DC Re
16
92.801k
33.6
+0.1
+0.0
+2.0
+0.0
35.7
66.0
-30.3
DC Re
17
13.149k
24.8
+0.1
-0.1
+9.2
+0.0
34.0
66.0
-32.0
DC Re
18
10.899k
22.8
+0.1
-0.1
+10.4
+0.0
33.2
66.0
-32.8
DC Re
19
72.190k
30.5
+0.1
+0.0
+2.4
+0.0
33.0
66.0
-33.0
DC Re
20
14.949k
24.2
+0.1
+0.0
+8.5
+0.0
32.8
66.0
-33.2
DC Re
21
10.449k
21.7
+0.1
-0.1
+10.6
+0.0
32.3
66.0
-33.7
DC Re
22
11.259k
22.0
+0.1
-0.1
+10.2
+0.0
32.2
66.0
-33.8
DC Re
23
11.709k
22.3
+0.1
-0.1
+9.9
+0.0
32.2
66.0
-33.8
DC Re
24
29.889k
27.5
+0.1
+0.0
+4.6
+0.0
32.2
66.0
-33.8
DC Re
25
21.159k
25.3
+0.1
+0.0
+6.4
+0.0
31.8
66.0
-34.2
DC Re
26
19.719k
24.3
+0.1
+0.0
+6.8
+0.0
31.2
66.0
-34.8
DC Re
Page 24 of 161
Report No.: MIL05-043
27
24.579k
25.5
+0.1
+0.0
+5.6
+0.0
31.2
66.0
-34.8
DC Re
28
23.139k
24.7
+0.1
+0.0
+5.9
+0.0
30.7
66.0
-35.3
DC Re
29
21.519k
24.2
+0.1
+0.0
+6.3
+0.0
30.6
66.0
-35.4
DC Re
30
15.669k
22.1
+0.1
+0.0
+8.2
+0.0
30.4
66.0
-35.6
DC Re
Page 25 of 161
Report No.: MIL05-043
CECM – Conducted Emissions, Common Mode, DC to 150MHz
Test Equipment
Equipment
Oscilloscope
Manufacturer
HP
Model #
54615B
Serial #
US35420828
Asset #
00697
Cal Date
8/31/03
Cal Due
8/31/07
Test Procedure
Line to Chassis Ground: While the EUT was up and running in high noise mode, the Test
Engineer connected an oscilloscope from DC Line to chassis ground using 150MHz BW setting.
Changed the time scale on the oscilloscope from 1ns/division to 5s/divison and captured the
noise plots.
Return to Chassis Ground: While the EUT was up and running in high noise mode, the Test
Engineer connected an oscilloscope from Return Line to chassis ground using 150MHz BW
setting. Changed the time scale on the oscilloscope from 1ns/division to 5s/divison and captured
the noise plots.
Conducted Emissions, Common Mode
Page 26 of 161
Report No.: MIL05-043
CECM
DC Line
5s/Div
DC Line
200ms/Div
Page 27 of 161
Report No.: MIL05-043
DC Line
10ms/Div
DC Line
2ms/Div
Page 28 of 161
Report No.: MIL05-043
DC Line
100us/Div
DC Line
1ns/Div
Page 29 of 161
Report No.: MIL05-043
DC Line
5ns/Div
DC Line
1ns/Div
Page 30 of 161
Report No.: MIL05-043
DC Return
1ns/Div
DC Return
5ns/Div
Page 31 of 161
Report No.: MIL05-043
DC Return
20ns/Div
DC Return
5us/Div
Page 32 of 161
Report No.: MIL05-043
DC Return
200us/Div
DC Return
5ms/Div
Page 33 of 161
Report No.: MIL05-043
DC Return
50ms/Div
DC Return
1s/Div
Page 34 of 161
Report No.: MIL05-043
DC Return
5s/Div
Page 35 of 161
Report No.: MIL05-043
RE101 - Radiated Emissions, Magnetic Field, 30Hz to 100kHz
Test Equipment
Function
SA - E4446A
Sig Gen - 2022D
Cable
Cable RG214/U
Andrew Cable- CNT-195
Magnetic Loop Sensor - 7334-1
Asset #
02668
00727
P05309
02410
01189
00170
S/N
US44300408
119190-018
None
None
None
170
Cal Date
01/13/2005
11/15/2004
08/01/2005
06/07/2004
04/12/2004
03/04/2005
Cal Due
01/13/2007
11/15/2006
08/01/2007
06/07/2006
04/12/2006
03/04/2007
Test Procedure
A signal generator was connected into the measurement system. The test engineer performed a
path loss check by injecting a signal at 50kHz that was 6dB below the limit line and measuring
the resulting emission on the spectrum analyzer. Then, the signal generator was removed and the
test cable was connected from the loop sensor to the spectrum analyzer.
The UUT was powered up in standard operating mode. The loop was placed 7cm from the front
side of the UUT chassis and a scan was performed. Then, the loop was placed 7cm from the
backside of the UUT and the scan was repeated. Full scans were also performed on the top, left
and right sides of the UUT.
Page 36 of 161
Report No.: MIL05-043
RE101 Radiated Emissions, Magnetic Field Path Check
RE101 Radiated Emissions, Magnetic Field Test Setup
Page 37 of 161
Report No.: MIL05-043
Seq. #
0
22
Test Description
Radiated Emissions
Radiated Emissions
23
Radiated Emissions
24
Radiated Emissions
25
Radiated Emissions
26
Radiated Emissions
Test Lead or Location / Conditions
Path Check @ 50kHz
Back Side – Connectors / Power Cable is grounded to copper
table as it exits cage and to chamber wall before coming into
chamber.
Left Side / Power Cable is grounded to copper table as it exits
cage and to chamber wall before coming into chamber.
Front Side / Power Cable is grounded to copper table as it exits
cage and to chamber wall before coming into chamber.
Right Side / Power Cable is grounded to copper table as it exits
cage and to chamber wall before coming into chamber.
Top Side / Power Cable is grounded to copper table as it exits
cage and to chamber wall before coming into chamber.
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE101 Test Limit
82840
Radiated Scan
Date:
Time:
Sequence#:
Tested By:
10/21/2005
1:15:23 PM
0
A. Brar
Equipment Under Test (* = EUT):
Function
Manufacturer
Model #
S/N
Support Devices:
Function
Model #
S/N
Manufacturer
Test Conditions / Notes:
Path Check Sweep. Signal at 50KHz. 52 (spec limit) - 6dB - 27.5 (Antenna Factor) = 18.5dBuV signal level.
Transducer Legend:
T1=3.5' Cable AN 01189
T3=Cable 2410
T2=Cable P05309
T4=Loop Sensor 7334-1 dBpT
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
45.957k
19.6
+0.0
+0.1
+0.1
Test Distance:
T4
Dist
Corr
dB
Table
dBpt
+27.7 +0.0
47.5
None
Spec
dBpt
52.7
Margin
dB
-5.2
Polar
Ant
None
2
40.471k
15.1
+0.0
+0.0
+0.1
+27.9
+0.0
43.1
53.8
-10.7
None
3
.060k
18.3
+0.0
+0.0
+0.0
+75.4
+0.0
93.7
110.4
-16.7
None
Page 38 of 161
Report No.: MIL05-043
4
.179k
17.0
+0.0
+0.0
+0.0
+66.7
+0.0
83.7
100.9
-17.2
None
5
.299k
12.8
+0.0
+0.0
+0.0
+62.2
+0.0
75.0
96.5
-21.5
None
6
37.788k
2.8
+0.0
+0.0
+0.1
+28.0
+0.0
30.9
54.4
-23.5
None
7
47.839k
-0.6
+0.0
+0.1
+0.1
+27.6
+0.0
27.2
52.4
-25.2
None
8
35.626k
0.6
+0.0
+0.0
+0.1
+28.1
+0.0
28.8
54.9
-26.1
None
9
20.610k
3.6
+0.0
+0.0
+0.1
+29.8
+0.0
33.5
59.7
-26.2
None
10
29.139k
1.6
+0.0
+0.0
+0.1
+28.6
+0.0
30.3
56.7
-26.4
None
11
32.423k
1.0
+0.0
+0.0
+0.1
+28.3
+0.0
29.4
55.8
-26.4
None
12
33.103k
0.7
+0.0
+0.0
+0.1
+28.3
+0.0
29.1
55.6
-26.5
None
13
34.345k
0.5
+0.0
+0.0
+0.1
+28.2
+0.0
28.8
55.3
-26.5
None
14
15.965k
4.3
+0.0
+0.0
+0.1
+30.8
+0.0
35.2
61.9
-26.7
None
15
23.894k
2.2
+0.0
+0.0
+0.1
+29.3
+0.0
31.6
58.4
-26.8
None
16
27.858k
1.3
+0.0
+0.0
+0.1
+28.8
+0.0
30.2
57.1
-26.9
None
17
10.159k
4.3
+0.1
-0.1
+0.1
+33.4
+0.0
37.8
65.9
-28.1
None
18
.239k
1.2
+0.0
+0.0
+0.0
+64.2
+0.0
65.4
98.4
-33.0
None
19
.119k
1.2
+0.0
+0.0
+0.0
+70.2
+0.0
71.4
104.5
-33.1
None
20
.420k
-0.5
+0.0
+0.0
+0.0
+59.3
+0.0
58.8
93.5
-34.7
None
21
1.119k
-1.0
+0.0
+0.0
+0.0
+51.3
+0.0
50.3
85.0
-34.7
None
22
1.231k
-1.0
+0.0
+0.0
+0.0
+50.5
+0.0
49.5
84.2
-34.7
None
23
.539k
-0.6
+0.0
+0.0
+0.0
+57.2
+0.0
56.6
91.4
-34.8
None
24
.112k
-1.3
+0.0
+0.0
+0.0
+70.7
+0.0
69.4
105.0
-35.6
None
Page 39 of 161
Report No.: MIL05-043
25
3.658k
-2.3
+0.0
+0.0
+0.0
+41.4
+0.0
39.1
74.7
-35.6
None
26
.359k
-1.5
+0.0
+0.0
+0.0
+60.7
+0.0
59.2
94.9
-35.7
None
27
.658k
-1.7
+0.0
+0.0
+0.0
+55.6
+0.0
53.9
89.6
-35.7
None
28
3.082k
-2.5
+0.0
+0.0
+0.0
+42.8
+0.0
40.3
76.2
-35.9
None
29
3.794k
-3.1
+0.0
+0.0
+0.0
+41.0
+0.0
37.9
74.4
-36.5
None
30
3.330k
-3.3
+0.0
+0.0
+0.0
+42.2
+0.0
38.9
75.5
-36.6
None
Page 40 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE101 Test Limit
82840
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/21/2005
1:58:11 PM
22
A. Brar
Model #
SIU
Support Devices:
Function
PC
Monitor
Manufacturer
Dell
Dell
Keyboard
Dell
Model #
DHM
MX-D9J367-47605-379AYKJ
04N454
Mouse
VME Crate
Power Supply
Dell by Microsoft
Dawn
AEMC Instruments
X06-08477
11-1011777-2119
AX502
S/N
GLAT 2508
S/N
JLJJ331
PC65341
TH-04N454-37171-33FE488
none
002563
PC70344
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber. Back Side - Connectors
Transducer Legend:
T1=3.5' Cable AN 01189
T3=Cable 2410
T2=Cable P05309
T4=Loop Sensor 7334-1 dBpT
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
40.551k
11.6
+0.0
+0.0
+0.1
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table
dBpt
dBpt
dB
+27.9 +0.0
39.6
53.8
-14.2
Polar
Ant
Magne
2
.056k
19.7
+0.0
+0.0
+0.0
+76.0
+0.0
95.7
111.1
-15.4
Magne
3
47.398k
-0.7
+0.0
+0.1
+0.1
+27.6
+0.0
27.1
52.5
-25.4
Magne
4
17.687k
4.7
+0.0
+0.0
+0.1
+30.4
+0.0
35.2
61.0
-25.8
Magne
5
9.999k
6.4
+0.0
+0.0
+0.1
+33.5
+0.0
40.0
66.0
-26.0
Magne
Page 41 of 161
Report No.: MIL05-043
6
14.444k
5.3
+0.0
+0.0
+0.1
+31.2
+0.0
36.6
62.8
-26.2
Magne
7
11.681k
5.5
+0.1
-0.1
+0.1
+32.5
+0.0
38.1
64.6
-26.5
Magne
8
21.811k
2.8
+0.0
+0.0
+0.1
+29.6
+0.0
32.5
59.2
-26.7
Magne
9
26.136k
1.7
+0.0
+0.0
+0.1
+29.0
+0.0
30.8
57.6
-26.8
Magne
10
27.778k
1.4
+0.0
+0.0
+0.1
+28.8
+0.0
30.3
57.1
-26.8
Magne
11
33.904k
0.3
+0.0
+0.0
+0.1
+28.2
+0.0
28.6
55.4
-26.8
Magne
12
31.021k
0.3
+0.0
+0.0
+0.1
+28.4
+0.0
28.8
56.1
-27.3
Magne
13
.110k
6.4
+0.0
+0.0
+0.0
+70.9
+0.0
77.3
105.2
-27.9
Magne
14
.180k
3.2
+0.0
+0.0
+0.0
+66.6
+0.0
69.8
100.9
-31.1
Magne
15
.220k
1.4
+0.0
+0.0
+0.0
+64.9
+0.0
66.3
99.1
-32.8
Magne
16
1.792k
0.7
+0.0
+0.0
+0.0
+47.4
+0.0
48.1
80.9
-32.8
Magne
17
1.600k
0.2
+0.0
+0.0
+0.0
+48.3
+0.0
48.5
81.9
-33.4
Magne
18
.330k
0.7
+0.0
+0.0
+0.0
+61.4
+0.0
62.1
95.6
-33.5
Magne
19
1.055k
0.0
+0.0
+0.0
+0.0
+51.7
+0.0
51.7
85.5
-33.8
Magne
20
1.456k
-0.4
+0.0
+0.0
+0.0
+49.1
+0.0
48.7
82.7
-34.0
Magne
21
.299k
-0.1
+0.0
+0.0
+0.0
+62.3
+0.0
62.2
96.5
-34.3
Magne
22
3.450k
-0.9
+0.0
+0.0
+0.0
+41.8
+0.0
40.9
75.2
-34.3
Magne
23
1.944k
-1.3
+0.0
+0.0
+0.0
+46.7
+0.0
45.4
80.2
-34.8
Magne
24
3.346k
-1.4
+0.0
+0.0
+0.0
+42.1
+0.0
40.7
75.5
-34.8
Magne
25
4.459k
-1.7
+0.0
+0.0
+0.0
+39.7
+0.0
38.0
73.0
-35.0
Magne
26
1.271k
-1.4
+0.0
+0.0
+0.0
+50.2
+0.0
48.8
83.9
-35.1
Magne
Page 42 of 161
Report No.: MIL05-043
27
9.387k
-2.6
+0.0
+0.0
+0.1
+33.9
+0.0
31.4
66.5
-35.1
Magne
28
4.796k
-1.8
+0.0
+0.0
+0.0
+39.0
+0.0
37.2
72.4
-35.2
Magne
29
8.777k
-2.3
+0.0
+0.0
+0.0
+34.2
+0.0
31.9
67.1
-35.2
Magne
30
9.203k
-2.6
+0.0
+0.0
+0.1
+34.0
+0.0
31.5
66.7
-35.2
Magne
Page 43 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE101 Test Limit
82840
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/21/2005
2:05:28 PM
23
A. Brar
Model #
SIU
Support Devices:
Function
PC
Monitor
Manufacturer
Dell
Dell
Keyboard
Dell
Model #
DHM
MX-D9J367-47605-379AYKJ
04N454
Mouse
VME Crate
Power Supply
Dell by Microsoft
Dawn
AEMC Instruments
X06-08477
11-1011777-2119
AX502
S/N
GLAT 2508
S/N
JLJJ331
PC65341
TH-04N454-37171-33FE488
none
002563
PC70344
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber. Left Side
Transducer Legend:
T1=3.5' Cable AN 01189
T3=Cable 2410
T2=Cable P05309
T4=Loop Sensor 7334-1 dBpT
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
40.431k
11.2
+0.0
+0.0
+0.1
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table
dBpt
dBpt
dB
+27.9 +0.0
39.2
53.8
-14.6
Polar
Ant
Magne
2
.059k
19.6
+0.0
+0.0
+0.0
+75.5
+0.0
95.1
110.5
-15.4
Magne
3
17.367k
6.7
+0.0
+0.0
+0.1
+30.4
+0.0
37.2
61.2
-24.0
Magne
4
48.199k
-0.6
+0.0
+0.1
+0.1
+27.6
+0.0
27.2
52.3
-25.1
Magne
5
37.067k
1.0
+0.0
+0.0
+0.1
+28.1
+0.0
29.2
54.6
-25.4
Magne
Page 44 of 161
Report No.: MIL05-043
6
19.449k
4.6
+0.0
+0.0
+0.1
+30.0
+0.0
34.7
60.2
-25.5
Magne
7
22.012k
3.7
+0.0
+0.0
+0.1
+29.6
+0.0
33.4
59.1
-25.7
Magne
8
34.264k
1.3
+0.0
+0.0
+0.1
+28.2
+0.0
29.6
55.3
-25.7
Magne
9
16.366k
5.1
+0.0
+0.0
+0.1
+30.7
+0.0
35.9
61.7
-25.8
Magne
10
12.802k
5.5
+0.1
-0.1
+0.1
+32.0
+0.0
37.6
63.8
-26.2
Magne
11
25.215k
2.5
+0.0
+0.0
+0.1
+29.1
+0.0
31.7
57.9
-26.2
Magne
12
11.400k
5.7
+0.1
-0.1
+0.1
+32.7
+0.0
38.5
64.8
-26.3
Magne
13
29.980k
1.5
+0.0
+0.0
+0.1
+28.5
+0.0
30.1
56.4
-26.3
Magne
14
35.426k
0.3
+0.0
+0.0
+0.1
+28.2
+0.0
28.6
55.0
-26.4
Magne
15
14.724k
4.7
+0.0
+0.0
+0.1
+31.1
+0.0
35.9
62.6
-26.7
Magne
16
37.988k
-0.5
+0.0
+0.0
+0.1
+28.0
+0.0
27.6
54.4
-26.8
Magne
17
18.568k
3.4
+0.0
+0.0
+0.1
+30.2
+0.0
33.7
60.6
-26.9
Magne
18
45.116k
-2.0
+0.0
+0.1
+0.1
+27.7
+0.0
25.9
52.9
-27.0
Magne
19
32.503k
0.2
+0.0
+0.0
+0.1
+28.3
+0.0
28.6
55.7
-27.1
Magne
20
43.194k
-1.7
+0.0
+0.0
+0.1
+27.8
+0.0
26.2
53.3
-27.1
Magne
21
23.373k
1.7
+0.0
+0.0
+0.1
+29.4
+0.0
31.2
58.6
-27.4
Magne
22
33.424k
-0.3
+0.0
+0.0
+0.1
+28.3
+0.0
28.1
55.5
-27.4
Magne
23
36.186k
-0.8
+0.0
+0.0
+0.1
+28.1
+0.0
27.4
54.8
-27.4
Magne
24
27.177k
0.7
+0.0
+0.0
+0.1
+28.8
+0.0
29.6
57.3
-27.7
Magne
25
38.749k
-1.6
+0.0
+0.0
+0.1
+28.0
+0.0
26.5
54.2
-27.7
Magne
Page 45 of 161
Report No.: MIL05-043
26
49.200k
-3.4
+0.0
+0.1
+0.1
+27.5
+0.0
24.3
52.1
-27.8
Magne
27
26.216k
0.6
+0.0
+0.0
+0.1
+29.0
+0.0
29.7
57.6
-27.9
Magne
28
23.814k
0.1
+0.0
+0.0
+0.1
+29.3
+0.0
29.5
58.4
-28.9
Magne
29
.110k
3.4
+0.0
+0.0
+0.0
+70.9
+0.0
74.3
105.2
-30.9
Magne
30
2.160k
1.9
+0.0
+0.0
+0.0
+45.8
+0.0
47.7
79.3
-31.6
Magne
Page 46 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE101 Test Limit
82840
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
PC
Monitor
Keyboard
Mouse
VME Crate
Power Supply
Manufacturer
Dell
Dell
Dell
Dell by Microsoft
Dawn
AEMC Instruments
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/21/2005
2:10:44 PM
24
A. Brar
Model #
SIU
Model #
DHM
MX-D9J367-47605-379-AYKJ
04N454
X06-08477
11-1011777-2119
AX502
S/N
GLAT 2508
S/N
JLJJ331
PC65341
TH-04N454-37171-33F-E488
none
002563
PC70344
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber. Front Side
Transducer Legend:
T1=3.5' Cable AN 01189
T3=Cable 2410
T2=Cable P05309
T4=Loop Sensor 7334-1 dBpT
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
40.591k
11.7
+0.0
+0.0
+0.1
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table
dBpt
dBpt
dB
+27.9 +0.0
39.7
53.8
-14.1
Polar
Ant
Magne
2
.055k
17.2
+0.0
+0.0
+0.0
+76.1
+0.0
93.3
111.2
-17.9
Magne
3
14.524k
6.6
+0.0
+0.0
+0.1
+31.2
+0.0
37.9
62.7
-24.8
Magne
4
47.639k
-0.8
+0.0
+0.1
+0.1
+27.6
+0.0
27.0
52.4
-25.4
Magne
5
48.760k
-0.9
+0.0
+0.1
+0.1
+27.5
+0.0
26.8
52.2
-25.4
Magne
6
21.972k
3.2
+0.0
+0.0
+0.1
+29.6
+0.0
32.9
59.1
-26.2
Magne
Page 47 of 161
Report No.: MIL05-043
7
10.199k
5.7
+0.1
-0.1
+0.1
+33.4
+0.0
39.2
65.8
-26.6
Magne
8
29.780k
1.1
+0.0
+0.0
+0.1
+28.5
+0.0
29.7
56.5
-26.8
Magne
9
13.483k
4.4
+0.1
-0.1
+0.1
+31.7
+0.0
36.2
63.4
-27.2
Magne
10
17.407k
3.5
+0.0
+0.0
+0.1
+30.4
+0.0
34.0
61.2
-27.2
Magne
11
24.174k
1.4
+0.0
+0.0
+0.1
+29.2
+0.0
30.7
58.3
-27.6
Magne
12
25.535k
0.8
+0.0
+0.0
+0.1
+29.1
+0.0
30.0
57.8
-27.8
Magne
13
43.314k
-2.6
+0.0
+0.0
+0.1
+27.8
+0.0
25.3
53.2
-27.9
Magne
14
.110k
5.9
+0.0
+0.0
+0.0
+70.9
+0.0
76.8
105.2
-28.4
Magne
15
33.744k
-1.5
+0.0
+0.0
+0.1
+28.3
+0.0
26.9
55.4
-28.5
Magne
16
.181k
2.7
+0.0
+0.0
+0.0
+66.6
+0.0
69.3
100.8
-31.5
Magne
17
.299k
2.7
+0.0
+0.0
+0.0
+62.2
+0.0
64.9
96.5
-31.6
Magne
18
1.552k
1.7
+0.0
+0.0
+0.0
+48.6
+0.0
50.3
82.2
-31.9
Magne
19
2.337k
0.8
+0.0
+0.0
+0.0
+45.2
+0.0
46.0
78.6
-32.6
Magne
20
1.119k
1.0
+0.0
+0.0
+0.0
+51.3
+0.0
52.3
85.0
-32.7
Magne
21
2.921k
0.6
+0.0
+0.0
+0.0
+43.3
+0.0
43.9
76.7
-32.8
Magne
22
1.736k
0.3
+0.0
+0.0
+0.0
+47.7
+0.0
48.0
81.2
-33.2
Magne
23
3.258k
0.0
+0.0
+0.0
+0.0
+42.3
+0.0
42.3
75.7
-33.4
Magne
24
6.934k
-0.2
+0.0
+0.0
+0.0
+35.9
+0.0
35.7
69.2
-33.5
Magne
25
4.243k
-0.3
+0.0
+0.0
+0.0
+40.1
+0.0
39.8
73.4
-33.6
Magne
26
.220k
0.5
+0.0
+0.0
+0.0
+64.9
+0.0
65.4
99.1
-33.7
Magne
27
.330k
0.5
+0.0
+0.0
+0.0
+61.4
+0.0
61.9
95.6
-33.7
Magne
Page 48 of 161
Report No.: MIL05-043
28
1.952k
-0.4
+0.0
+0.0
+0.0
+46.7
+0.0
46.3
80.2
-33.9
Magne
29
3.458k
-0.9
+0.0
+0.0
+0.0
+41.8
+0.0
40.9
75.2
-34.3
Magne
30
4.676k
-1.5
+0.0
+0.0
+0.0
+39.2
+0.0
37.7
72.6
-34.9
Magne
Page 49 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE101 Test Limit
82840
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
PC
Monitor
Keyboard
Mouse
VME Crate
Power Supply
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
Dell
Dell
Dell
Dell by Microsoft
Dawn
AEMC Instruments
10/21/2005
2:13:39 PM
25
A. Brar
Model #
SIU
S/N
GLAT 2508
Model #
DHM
MX-D9J367-47605-379-AYKJ
04N454
X06-08477
11-1011777-2119
AX502
S/N
JLJJ331
PC65341
TH-04N454-37171-33F-E488
none
002563
PC70344
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber. Right Side
Transducer Legend:
T1=3.5' Cable AN 01189
T3=Cable 2410
T2=Cable P05309
T4=Loop Sensor 7334-1 dBpT
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
40.511k
10.4
+0.0
+0.0
+0.1
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table
dBpt
dBpt
dB
+27.9 +0.0
38.4
53.8
-15.4
Polar
Ant
Magne
2
.061k
17.5
+0.0
+0.0
+0.0
+75.3
+0.0
92.8
110.3
-17.5
Magne
3
.054k
17.5
+0.0
+0.0
+0.0
+76.3
+0.0
93.8
111.4
-17.6
Magne
4
44.836k
1.1
+0.0
+0.1
+0.1
+27.7
+0.0
29.0
52.9
-23.9
Magne
5
49.921k
-0.4
+0.0
+0.1
+0.1
+27.5
+0.0
27.3
52.0
-24.7
Magne
6
12.642k
7.0
+0.1
-0.1
+0.1
+32.1
+0.0
39.2
64.0
-24.8
Magne
Page 50 of 161
Report No.: MIL05-043
7
46.958k
-0.6
+0.0
+0.1
+0.1
+27.6
+0.0
27.2
52.5
-25.3
Magne
8
34.264k
1.4
+0.0
+0.0
+0.1
+28.2
+0.0
29.7
55.3
-25.6
Magne
9
22.052k
3.6
+0.0
+0.0
+0.1
+29.6
+0.0
33.3
59.1
-25.8
Magne
10
48.800k
-1.6
+0.0
+0.1
+0.1
+27.5
+0.0
26.1
52.2
-26.1
Magne
11
45.717k
-1.4
+0.0
+0.1
+0.1
+27.7
+0.0
26.5
52.8
-26.3
Magne
12
20.410k
3.3
+0.0
+0.0
+0.1
+29.8
+0.0
33.2
59.8
-26.6
Magne
13
21.491k
2.9
+0.0
+0.0
+0.1
+29.6
+0.0
32.6
59.3
-26.7
Magne
14
11.441k
5.2
+0.1
-0.1
+0.1
+32.7
+0.0
38.0
64.8
-26.8
Magne
15
32.142k
0.4
+0.0
+0.0
+0.1
+28.4
+0.0
28.9
55.8
-26.9
Magne
16
17.287k
3.4
+0.0
+0.0
+0.1
+30.5
+0.0
34.0
61.2
-27.2
Magne
17
18.648k
2.6
+0.0
+0.0
+0.1
+30.2
+0.0
32.9
60.6
-27.7
Magne
18
26.456k
0.5
+0.0
+0.0
+0.1
+28.9
+0.0
29.5
57.5
-28.0
Magne
19
24.975k
0.6
+0.0
+0.0
+0.1
+29.1
+0.0
29.8
58.0
-28.2
Magne
20
.109k
5.5
+0.0
+0.0
+0.0
+71.0
+0.0
76.5
105.3
-28.8
Magne
21
1.079k
3.0
+0.0
+0.0
+0.0
+51.6
+0.0
54.6
85.3
-30.7
Magne
22
2.713k
2.4
+0.0
+0.0
+0.0
+43.9
+0.0
46.3
77.3
-31.0
Magne
23
.180k
2.8
+0.0
+0.0
+0.0
+66.6
+0.0
69.4
100.9
-31.5
Magne
24
.298k
2.5
+0.0
+0.0
+0.0
+62.3
+0.0
64.8
96.5
-31.7
Magne
25
1.375k
1.6
+0.0
+0.0
+0.0
+49.6
+0.0
51.2
83.2
-32.0
Magne
26
4.860k
1.3
+0.0
+0.0
+0.0
+38.9
+0.0
40.2
72.3
-32.1
Magne
27
3.114k
0.4
+0.0
+0.0
+0.0
+42.7
+0.0
43.1
76.1
-33.0
Magne
Page 51 of 161
Report No.: MIL05-043
28
2.209k
0.3
+0.0
+0.0
+0.0
+45.7
+0.0
46.0
79.1
-33.1
Magne
29
4.523k
0.3
+0.0
+0.0
+0.0
+39.5
+0.0
39.8
72.9
-33.1
Magne
30
.218k
0.8
+0.0
+0.0
+0.0
+65.0
+0.0
65.8
99.2
-33.4
Magne
Page 52 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE101 Test Limit
82840
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
PC
Monitor
Keyboard
Mouse
VME Crate
Power Supply
Manufacturer
Dell
Dell
Dell
Dell by Microsoft
Dawn
AEMC Instruments
Manufacturer
Stanford Linear
Date:
Time:
Sequence#:
Tested By:
10/21/2005
2:15:25 PM
26
A. Brar
Model #
SIU
Model #
DHM
MX-D9J367-47605-379-AYKJ
04N454
X06-08477
11-1011777-2119
AX502
S/N
GLAT 2508
S/N
JLJJ331
PC65341
TH-04N454-37171-33F-E488
none
002563
PC70344
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber. Top Side
Transducer Legend:
T1=3.5' Cable AN 01189
T3=Cable 2410
T2=Cable P05309
T4=Loop Sensor 7334-1 dBpT
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
40.551k
11.2
+0.0
+0.0
+0.1
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table
dBpt
dBpt
dB
+27.9 +0.0
39.2
53.8
-14.6
Polar
Ant
Magne
2
.054k
19.9
+0.0
+0.0
+0.0
+76.2
+0.0
96.1
111.3
-15.2
Magne
3
46.037k
-0.4
+0.0
+0.1
+0.1
+27.6
+0.0
27.4
52.7
-25.3
Magne
4
47.879k
-1.4
+0.0
+0.1
+0.1
+27.6
+0.0
26.4
52.4
-26.0
Magne
5
26.136k
2.4
+0.0
+0.0
+0.1
+29.0
+0.0
31.5
57.6
-26.1
Magne
6
20.770k
3.5
+0.0
+0.0
+0.1
+29.8
+0.0
33.4
59.6
-26.2
Magne
Page 53 of 161
Report No.: MIL05-043
7
12.602k
5.1
+0.1
-0.1
+0.1
+32.1
+0.0
37.3
64.0
-26.7
Magne
8
16.686k
4.0
+0.0
+0.0
+0.1
+30.6
+0.0
34.7
61.5
-26.8
Magne
9
18.728k
2.9
+0.0
+0.0
+0.1
+30.1
+0.0
33.1
60.5
-27.4
Magne
10
24.694k
1.1
+0.0
+0.0
+0.1
+29.2
+0.0
30.4
58.1
-27.7
Magne
11
30.460k
-0.3
+0.0
+0.0
+0.1
+28.5
+0.0
28.3
56.3
-28.0
Magne
12
1.215k
3.9
+0.0
+0.0
+0.0
+50.6
+0.0
54.5
84.3
-29.8
Magne
13
.218k
3.9
+0.0
+0.0
+0.0
+65.0
+0.0
68.9
99.2
-30.3
Magne
14
1.103k
3.2
+0.0
+0.0
+0.0
+51.4
+0.0
54.6
85.1
-30.5
Magne
15
.110k
3.5
+0.0
+0.0
+0.0
+70.9
+0.0
74.4
105.2
-30.8
Magne
16
9.306k
0.3
+0.0
+0.0
+0.1
+33.9
+0.0
34.3
66.6
-32.3
Magne
17
1.648k
0.9
+0.0
+0.0
+0.0
+48.1
+0.0
49.0
81.7
-32.7
Magne
18
4.275k
0.7
+0.0
+0.0
+0.0
+40.0
+0.0
40.7
73.4
-32.7
Magne
19
2.289k
0.7
+0.0
+0.0
+0.0
+45.3
+0.0
46.0
78.8
-32.8
Magne
20
9.527k
-0.3
+0.0
+0.0
+0.1
+33.8
+0.0
33.6
66.4
-32.8
Magne
21
2.537k
0.5
+0.0
+0.0
+0.0
+44.5
+0.0
45.0
77.9
-32.9
Magne
22
3.394k
0.4
+0.0
+0.0
+0.0
+42.0
+0.0
42.4
75.4
-33.0
Magne
23
3.738k
0.3
+0.0
+0.0
+0.0
+41.2
+0.0
41.5
74.5
-33.0
Magne
24
1.536k
0.4
+0.0
+0.0
+0.0
+48.7
+0.0
49.1
82.3
-33.2
Magne
25
.297k
0.9
+0.0
+0.0
+0.0
+62.3
+0.0
63.2
96.5
-33.3
Magne
26
.179k
0.8
+0.0
+0.0
+0.0
+66.7
+0.0
67.5
100.9
-33.4
Magne
27
2.008k
-0.6
+0.0
+0.0
+0.0
+46.5
+0.0
45.9
79.9
-34.0
Magne
Page 54 of 161
Report No.: MIL05-043
28
9.856k
-2.1
+0.0
+0.0
+0.1
+33.6
+0.0
31.6
66.1
-34.5
Magne
29
3.130k
-1.4
+0.0
+0.0
+0.0
+42.7
+0.0
41.3
76.1
-34.8
Magne
30
2.665k
-2.0
+0.0
+0.0
+0.0
+44.1
+0.0
42.1
77.5
-35.4
Magne
Page 55 of 161
Report No.: MIL05-043
RE102 - Radiated Emissions, Electric Field, 10kHz to 18GHz
Test Equipment
Function
SA - E4446A
Rod Antenna - 3301B
Sig Gen - 2022D
Cable
Cable RG214/U
Andrew Cable- CNT-195
Bicon Antenna EMCO3104
Horn - SAS 570
HF Pre AmpCable, 72" 2.92mm 40 GHz
Horn Antenna 3115
HF Cable - PE35591-60
Asset #
02668
01579
00727
P05309
02410
01189
00732
02525
00785
P05317
02113
02716
S/N
US44300408
92073275
119190-018
None
None
None
2683
155 part # 2490
3123A00283
None
9606-4660
None
Cal Date
01/13/2005
01/12/2004
11/15/2004
08/01/2005
06/07/2004
04/12/2004
04/11/2005
06/10/2005
05/09/2005
07/12/2005
03/08/2005
08/09/2005
Cal Due
01/13/2007
01/12/2006
11/15/2006
08/01/2007
06/07/2006
04/12/2006
04/11/2007
06/10/2007
05/09/2007
07/12/2007
03/08/2007
08/09/2007
Test Procedure
The signal generator was connected to the rod antenna through the calibration fixture. The test
engineer injected a signal at 2MHz that was 6dB below the limit line and measured the resulting
emission on the spectrum analyzer. The check was repeated at 15MHz and 30MHz. Then, the
signal generator was removed and the antenna element was connected to the antenna and the
antenna output was connected to the measurement system.
The UUT was powered up in standard operating mode. The rod antenna was placed one meter in
front of the UUT. The EMITest™ software automatically scanned from 10kHz to 30MHz using
the sweep rates required by the Test Procedure. The biconical antenna was placed one meter in
front of the UUT and was connected to the measurement system. The test engineer removed
performed a path loss check at 200MHz. The EMITest™ software automatically scanned from
30MHz to 200MHz in horizontal and vertical antenna polarizations using the sweep rates
required by the Test Procedure. The double ridge guide horn antenna was connected into the
setup and placed one meter from the UUT setup. The test engineer performed a path loss check
at 1GHz. The EMITest™ software automatically scanned from 200MHz to 1GHz in horizontal
and vertical antenna polarizations using the sweep rates required by the Test Procedure. Then,
the high frequency double ridge guide horn antenna was installed and placed one meter from the
UUT setup. The antenna was then connected to the measurement system. The test engineer
performed a path loss check at 18GHz. The EMITest™ software automatically scanned from
1GHz to 18GHz in horizontal and vertical antenna polarizations using the sweep rates required
by the Test Procedure with the exception of 1.55 – 1.6 / Vertical, 1kHz RBW, where 1kHz RBW
was used per Fred (Witness).
Page 56 of 161
Report No.: MIL05-043
Rod Antenna, 10kHz - 30MHz Path Check
Rod Antenna, 10kHz - 30MHz Test Setup
Page 57 of 161
Report No.: MIL05-043
Bicon Antenna and Log Periodic Antenna Path Check
Bicon Antenna, 30 - 200MHz Vertical Polarization Test Setup
Page 58 of 161
Report No.: MIL05-043
Horn Antenna, 200 - 1000MHz Vertical Polarization Test Setup
Horn Antenna, 200 - 1000MHz Vertical Polarization Closeup
Page 59 of 161
Report No.: MIL05-043
RE102 Path Check for High Frequency Horn Antenna
Horn Antenna, 8 - 18GHz Vertical Polarization Test Setup
Page 60 of 161
Report No.: MIL05-043
RE102, 1 - 18GHz Solution for Sequence 19
Data Sheets
Seq. #
Test Description
0
Radiated Emissions
0
Radiated Emissions
0
Radiated Emissions
1
Radiated Emissions
3
Radiated Emissions
2
Radiated Emissions
0
Radiated Emissions
0
Radiated Emissions
5
Radiated Emissions
4
Radiated Emissions
11
Radiated Emissions
6
Radiated Emissions
15
Radiated Emissions
19
Radiated Emissions
12
Radiated Emissions
7
Radiated Emissions
14
Radiated Emissions
10
Radiated Emissions
0
Radiated Emissions
13
Radiated Emissions
8
Radiated Emissions
Frequency / Polarity
10kHz Path Check
15MHz Path Check
30MHz Path Check
10kHz – 30MHz / Vertical
30 – 200MHz / Horizontal
30 – 200MHz / Vertical
200MHz Path Check
1000MHz Path Check
200 – 1000MHz / Horizontal
200 – 1000MHz / Vertical
1 – 1.55GHz / Horizontal
1 – 1.55GHz / Vertical
1.55 – 1.6 / Horizontal
1.55 – 1.6 / Vertical, 1kHz RBW
1.6 – 1.77GHz / Horizontal
1.6 – 1.77GHz / Vertical
1.77 – 2.3GHz / Horizontal
1.77 – 2.3GHz / Vertical
18GHz Path Check
2.3 – 18GHz / Horizontal
2.3 – 18GHz / Vertical
Page 61 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
82840
Radiated Scan
Date:
Time:
Sequence#:
Tested By:
10/19/2005
1:06:22 PM
0
A. Brar
Equipment Under Test (* = EUT):
Function
Manufacturer
Model #
S/N
Support Devices:
Function
Model #
S/N
Manufacturer
Test Conditions / Notes:
Path Check Sweep. Signal at 10KHz. 90 (spec limit) - 6dB - 4.2 (Antenna Factor) = 79.8dBuV signal level.
Transducer Legend:
T1=AN 01579 Rod Antenna
T3=Cable P05309
T2=3.5' Cable AN 01189
T4=Cable 2410
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1
10.000k
80.8
+4.2
+0.1
-0.1
Test Distance: None
T4
Dist
Corr
Spec
dB
Table dBµV/m dBµV/m
+0.1 +0.0
85.1
90.0
Margin
dB
-4.9
Polar
Ant
None
2
91.877k
25.9
+4.0
+0.0
+0.0
+0.1
+0.0
30.0
90.0
-60.0
None
3
28.388k
25.0
+4.0
+0.0
+0.0
+0.1
+0.0
29.1
90.0
-60.9
None
4
30.938k
22.3
+4.0
+0.0
+0.0
+0.1
+0.0
26.4
90.0
-63.6
None
5
51.475k
22.1
+4.0
+0.0
+0.1
+0.1
+0.0
26.3
90.0
-63.7
None
6
36.576k
21.7
+4.0
+0.0
+0.0
+0.1
+0.0
25.8
90.0
-64.2
None
7
54.025k
21.5
+4.0
+0.0
+0.1
+0.1
+0.0
25.7
90.0
-64.3
None
8
41.408k
21.5
+4.0
+0.0
+0.0
+0.1
+0.0
25.6
90.0
-64.4
None
9
43.556k
21.0
+4.0
+0.0
+0.0
+0.1
+0.0
25.1
90.0
-64.9
None
10
48.925k
20.9
+4.0
+0.0
+0.1
+0.1
+0.0
25.1
90.0
-64.9
None
Page 62 of 161
Report No.: MIL05-043
11
40.603k
20.7
+4.0
+0.0
+0.0
+0.1
+0.0
24.8
90.0
-65.2
None
12
46.374k
20.6
+4.0
+0.0
+0.1
+0.1
+0.0
24.8
90.0
-65.2
None
13
56.710k
20.8
+4.0
+0.0
+0.0
+0.0
+0.0
24.8
90.0
-65.2
None
14
58.455k
20.7
+4.0
+0.0
+0.0
+0.0
+0.0
24.7
90.0
-65.3
None
15
49.730k
20.3
+4.0
+0.0
+0.1
+0.1
+0.0
24.5
90.0
-65.5
None
16
60.468k
20.4
+4.0
+0.0
+0.0
+0.0
+0.0
24.4
90.0
-65.6
None
17
69.058k
19.8
+4.0
+0.0
+0.0
+0.1
+0.0
23.9
90.0
-66.1
None
18
225.849k
19.8
+4.0
+0.0
+0.0
+0.0
+0.0
23.8
90.0
-66.2
None
19
55.904k
19.7
+4.0
+0.0
+0.0
+0.0
+0.0
23.7
90.0
-66.3
None
20
59.528k
19.6
+4.0
+0.0
+0.0
+0.0
+0.0
23.6
90.0
-66.4
None
21
66.508k
19.2
+4.0
+0.0
+0.0
+0.1
+0.0
23.3
90.0
-66.7
None
22
54.294k
19.0
+4.0
+0.0
+0.1
+0.1
+0.0
23.2
90.0
-66.8
None
23
429.349k
18.6
+4.1
+0.0
+0.1
+0.0
+0.0
22.8
90.0
-67.2
None
24
67.314k
18.5
+4.0
+0.0
+0.0
+0.1
+0.0
22.6
90.0
-67.4
None
25
70.266k
18.5
+4.0
+0.0
+0.0
+0.1
+0.0
22.6
90.0
-67.4
None
26
77.917k
18.3
+4.1
+0.0
+0.0
+0.0
+0.0
22.4
90.0
-67.6
None
27
110.266k
18.4
+4.0
+0.0
+0.0
+0.0
+0.0
22.4
90.0
-67.6
None
Page 63 of 161
Report No.: MIL05-043
28
79.394k
18.2
+4.1
+0.0
+0.0
+0.0
+0.0
22.3
90.0
-67.7
None
29
305.399k
18.3
+3.9
+0.0
+0.1
+0.0
+0.0
22.3
90.0
-67.7
None
30
101.004k
17.9
+4.0
+0.0
+0.0
+0.0
+0.0
21.9
90.0
-68.1
None
Page 64 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
82840
Radiated Scan
Date:
Time:
Sequence#:
Tested By:
10/19/2005
1:19:28 PM
0
A. Brar
Equipment Under Test (* = EUT):
Function
Manufacturer
Model #
S/N
Support Devices:
Function
Model #
S/N
Manufacturer
Test Conditions / Notes:
Path Check Sweep. Signal at 15.005MHz. 90 (spec limit) - 6dB - 6.9 (Antenna Factor) = 77.1dBuV signal level.
Transducer Legend:
T1=AN 01579 Rod Antenna
T3=Cable P05309
T2=3.5' Cable AN 01189
T4=Cable 2410
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 15.005M
78.0
+6.9
+0.1
+0.2
Test Distance: None
T4
Dist
Corr
Spec
dB
Table dBµV/m dBµV/m
+0.2 +0.0
85.4
90.0
Margin
dB
-4.6
Polar
Ant
None
2
10.536k
23.2
+4.2
+0.1
-0.1
+0.1
+0.0
27.5
90.0
-62.5
None
3
11.341k
21.7
+4.2
+0.1
-0.1
+0.1
+0.0
26.0
90.0
-64.0
None
4
12.549k
21.4
+4.1
+0.1
-0.1
+0.1
+0.0
25.6
90.0
-64.4
None
5
13.086k
21.1
+4.1
+0.1
-0.1
+0.1
+0.0
25.3
90.0
-64.7
None
6
13.892k
20.4
+4.1
+0.1
-0.1
+0.1
+0.0
24.6
90.0
-65.4
None
7
14.294k
20.2
+4.1
+0.0
+0.0
+0.1
+0.0
24.4
90.0
-65.6
None
8
16.710k
19.2
+4.1
+0.0
+0.0
+0.1
+0.0
23.4
90.0
-66.6
None
9
149.999k
19.3
+4.0
+0.0
+0.0
+0.0
+0.0
23.3
90.0
-66.7
None
10
179.599k
18.9
+4.0
+0.0
+0.0
+0.0
+0.0
22.9
90.0
-67.1
None
Page 65 of 161
Report No.: MIL05-043
11
17.247k
18.7
+4.0
+0.0
+0.0
+0.1
+0.0
22.8
90.0
-67.2
None
12
166.649k
18.7
+4.0
+0.0
+0.0
+0.0
+0.0
22.7
90.0
-67.3
None
13
153.699k
18.5
+4.0
+0.0
+0.0
+0.0
+0.0
22.5
90.0
-67.5
None
14
41.005k
18.1
+4.0
+0.0
+0.0
+0.1
+0.0
22.2
90.0
-67.8
None
15
172.199k
18.0
+4.0
+0.0
+0.0
+0.0
+0.0
22.0
90.0
-68.0
None
16
211.049k
17.9
+4.0
+0.0
+0.0
+0.0
+0.0
21.9
90.0
-68.1
None
17
22.079k
17.6
+4.0
+0.0
+0.0
+0.1
+0.0
21.7
90.0
-68.3
None
18
19.395k
17.4
+4.0
+0.0
+0.0
+0.1
+0.0
21.5
90.0
-68.5
None
19
220.299k
16.9
+4.0
+0.0
+0.0
+0.0
+0.0
20.9
90.0
-69.1
None
20
216.599k
16.5
+4.0
+0.0
+0.0
+0.0
+0.0
20.5
90.0
-69.5
None
21
1.168M
15.8
+4.2
+0.0
+0.0
+0.1
+0.0
20.1
90.0
-69.9
None
22
24.227k
15.9
+4.0
+0.0
+0.0
+0.1
+0.0
20.0
90.0
-70.0
None
23
23.690k
15.7
+4.0
+0.0
+0.0
+0.1
+0.0
19.8
90.0
-70.2
None
24
29.793M
7.9
+10.8
+0.1
+0.1
+0.3
+0.0
19.2
90.0
-70.8
None
25
29.864k
14.9
+4.0
+0.0
+0.0
+0.1
+0.0
19.0
90.0
-71.0
None
26
25.972k
14.8
+4.0
+0.0
+0.0
+0.1
+0.0
18.9
90.0
-71.1
None
27
26.784M
8.2
+10.0
+0.2
+0.2
+0.3
+0.0
18.9
90.0
-71.1
None
Page 66 of 161
Report No.: MIL05-043
28
27.985k
14.7
+4.0
+0.0
+0.0
+0.1
+0.0
18.8
90.0
-71.2
None
29
29.673M
7.5
+10.8
+0.1
+0.1
+0.3
+0.0
18.8
90.0
-71.2
None
30
29.880M
7.2
+10.9
+0.1
+0.1
+0.3
+0.0
18.6
90.0
-71.4
None
Page 67 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
82840
Radiated Scan
Date:
Time:
Sequence#:
Tested By:
10/19/2005
1:25:18 PM
0
A. Brar
Equipment Under Test (* = EUT):
Function
Manufacturer
Model #
S/N
Support Devices:
Function
Model #
S/N
Manufacturer
Test Conditions / Notes:
Path Check Sweep. Signal at 30.00MHz. 90 (spec limit) - 6dB - 10.9 (Antenna Factor) = 73.1dBuV signal level.
Transducer Legend:
T1=AN 01579 Rod Antenna
T3=Cable P05309
T2=3.5' Cable AN 01189
T4=Cable 2410
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 30.000M
70.7 +10.9
+0.1
+0.1
Test Distance: None
T4
Dist
Corr
Spec
dB
Table dBµV/m dBµV/m
+0.3 +0.0
82.1
90.0
Margin
dB
-7.9
Polar
Ant
None
2
10.133k
25.6
+4.2
+0.1
-0.1
+0.1
+0.0
29.9
90.0
-60.1
None
3
11.744k
25.0
+4.2
+0.1
-0.1
+0.1
+0.0
29.3
90.0
-60.7
None
4
15.234k
23.0
+4.1
+0.0
+0.0
+0.1
+0.0
27.2
90.0
-62.8
None
5
15.771k
22.2
+4.1
+0.0
+0.0
+0.1
+0.0
26.4
90.0
-63.6
None
6
29.697M
14.8
+10.8
+0.1
+0.1
+0.3
+0.0
26.1
90.0
-63.9
None
7
14.294k
20.6
+4.1
+0.0
+0.0
+0.1
+0.0
24.8
90.0
-65.2
None
8
153.699k
19.9
+4.0
+0.0
+0.0
+0.0
+0.0
23.9
90.0
-66.1
None
9
14.026k
19.3
+4.1
+0.1
-0.1
+0.1
+0.0
23.5
90.0
-66.5
None
10
14.831k
19.3
+4.1
+0.0
+0.0
+0.1
+0.0
23.5
90.0
-66.5
None
Page 68 of 161
Report No.: MIL05-043
11
40.737k
19.0
+4.0
+0.0
+0.0
+0.1
+0.0
23.1
90.0
-66.9
None
12
16.173k
18.7
+4.1
+0.0
+0.0
+0.1
+0.0
22.9
90.0
-67.1
None
13
179.599k
16.7
+4.0
+0.0
+0.0
+0.0
+0.0
20.7
90.0
-69.3
None
14
185.149k
16.7
+4.0
+0.0
+0.0
+0.0
+0.0
20.7
90.0
-69.3
None
15
201.799k
16.7
+4.0
+0.0
+0.0
+0.0
+0.0
20.7
90.0
-69.3
None
16
29.462k
16.2
+4.0
+0.0
+0.0
+0.1
+0.0
20.3
90.0
-69.7
None
17
22.616k
16.0
+4.0
+0.0
+0.0
+0.1
+0.0
20.1
90.0
-69.9
None
18
29.601M
8.5
+10.8
+0.1
+0.1
+0.3
+0.0
19.8
90.0
-70.2
None
19
23.422k
15.4
+4.0
+0.0
+0.0
+0.1
+0.0
19.5
90.0
-70.5
None
20
23.824k
15.3
+4.0
+0.0
+0.0
+0.1
+0.0
19.4
90.0
-70.6
None
21
22.722M
9.5
+8.9
+0.2
+0.2
+0.3
+0.0
19.1
90.0
-70.9
None
22
29.505M
7.8
+10.8
+0.1
+0.1
+0.3
+0.0
19.1
90.0
-70.9
None
23
24.262M
8.8
+9.3
+0.2
+0.2
+0.3
+0.0
18.8
90.0
-71.2
None
24
33.086k
14.6
+4.0
+0.0
+0.0
+0.1
+0.0
18.7
90.0
-71.3
None
25
28.580M
7.7
+10.5
+0.1
+0.1
+0.3
+0.0
18.7
90.0
-71.3
None
26
1.160M
14.3
+4.2
+0.0
+0.0
+0.1
+0.0
18.6
90.0
-71.4
None
27
28.412M
7.7
+10.4
+0.1
+0.1
+0.3
+0.0
18.6
90.0
-71.4
None
Page 69 of 161
Report No.: MIL05-043
28
27.391M
7.8
+10.2
+0.1
+0.1
+0.3
+0.0
18.5
90.0
-71.5
None
29
36.039k
14.3
+4.0
+0.0
+0.0
+0.1
+0.0
18.4
90.0
-71.6
None
30
366.449k
14.3
+4.0
+0.0
+0.1
+0.0
+0.0
18.4
90.0
-71.6
None
Page 70 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/19/2005
1:56:49 PM
1
A. Brar
Model #
SIU
S/N
GLAT 2508
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=AN 01579 Rod Antenna
T3=Cable P05309
T2=3.5' Cable AN 01189
T4=Cable 2410
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 23.233M
28.3
+9.0
+0.2
+0.2
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+0.3 +0.0
38.0
90.0
-52.0
Polar
Ant
Rod A
2
14.022M
29.0
+6.6
+0.1
+0.2
+0.2
+0.0
36.1
90.0
-53.9
Rod A
3
17.976M
25.9
+7.7
+0.1
+0.1
+0.3
+0.0
34.1
90.0
-55.9
Rod A
4
13.972M
26.8
+6.6
+0.1
+0.2
+0.2
+0.0
33.9
90.0
-56.1
Rod A
5
18.026M
25.6
+7.7
+0.1
+0.1
+0.3
+0.0
33.8
90.0
-56.2
Rod A
6
19.978M
24.8
+8.1
+0.1
+0.1
+0.3
+0.0
33.4
90.0
-56.6
Rod A
Page 71 of 161
Report No.: MIL05-043
7
10.670k
28.6
+4.2
+0.1
-0.1
+0.1
+0.0
32.9
90.0
-57.1
Rod A
8
20.028M
24.1
+8.1
+0.1
+0.1
+0.3
+0.0
32.7
90.0
-57.3
Rod A
9
23.991M
22.6
+9.2
+0.2
+0.2
+0.3
+0.0
32.5
90.0
-57.5
Rod A
10
22.994M
22.6
+9.0
+0.2
+0.2
+0.3
+0.0
32.3
90.0
-57.7
Rod A
11
24.023M
22.2
+9.2
+0.2
+0.2
+0.3
+0.0
32.1
90.0
-57.9
Rod A
12
15.974M
23.9
+7.2
+0.1
+0.2
+0.2
+0.0
31.6
90.0
-58.4
Rod A
13
19.998M
22.7
+8.1
+0.1
+0.1
+0.3
+0.0
31.3
90.0
-58.7
Rod A
14
16.024M
23.4
+7.2
+0.1
+0.2
+0.2
+0.0
31.1
90.0
-58.9
Rod A
15
12.549k
26.5
+4.1
+0.1
-0.1
+0.1
+0.0
30.7
90.0
-59.3
Rod A
16
17.175M
22.7
+7.5
+0.1
+0.2
+0.2
+0.0
30.7
90.0
-59.3
Rod A
17
13.892k
26.2
+4.1
+0.1
-0.1
+0.1
+0.0
30.4
90.0
-59.6
Rod A
18
1.168M
26.1
+4.2
+0.0
+0.0
+0.1
+0.0
30.4
90.0
-59.6
Rod A
19
15.544M
22.8
+7.1
+0.1
+0.2
+0.2
+0.0
30.4
90.0
-59.6
Rod A
20
1.587M
25.4
+4.3
+0.1
+0.0
+0.1
+0.0
29.9
90.0
-60.1
Rod A
21
15.203M
22.2
+7.0
+0.1
+0.2
+0.2
+0.0
29.7
90.0
-60.3
Rod A
22
16.965M
21.6
+7.4
+0.1
+0.2
+0.2
+0.0
29.5
90.0
-60.5
Rod A
23
18.176M
21.2
+7.7
+0.1
+0.1
+0.3
+0.0
29.4
90.0
-60.6
Rod A
24
15.771k
25.0
+4.1
+0.0
+0.0
+0.1
+0.0
29.2
90.0
-60.8
Rod A
25
816.000k
25.2
+4.0
+0.0
+0.0
+0.0
+0.0
29.2
90.0
-60.8
Rod A
26
16.174M
21.4
+7.2
+0.1
+0.2
+0.2
+0.0
29.1
90.0
-60.9
Rod A
27
1.519M
24.4
+4.3
+0.1
+0.0
+0.1
+0.0
28.9
90.0
-61.1
Rod A
Page 72 of 161
Report No.: MIL05-043
28
1.351M
24.5
+4.2
+0.0
+0.0
+0.1
+0.0
28.8
90.0
-61.2
Rod A
29
21.980M
19.6
+8.7
+0.1
+0.1
+0.3
+0.0
28.8
90.0
-61.2
Rod A
30
24.997M
18.5
+9.5
+0.2
+0.2
+0.3
+0.0
28.7
90.0
-61.3
Rod A
Page 73 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/19/2005
2:42:38 PM
3
A. Brar
Model #
SIU
S/N
GLAT 2508
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=8447D OPT 010 AN00686 SN 2944A08591
T3=Cable P05309
T5=Bicon AN732 4-11-05
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
T5
MHz
dBµV
dB
dB
dB
1 95.994M
51.0
-29.2
+0.2
+0.2
+13.4
2 132.019M
49.6
-29.1
+0.2
+0.3
+12.7
3 133.342M
49.1
-29.1
+0.2
+0.3
+12.7
4 199.976M
43.5
-28.8
+0.2
+0.3
+15.8
5 98.999M
46.4
-29.3
+0.2
+0.2
+12.3
T2=3.5' Cable AN 01189
T4=Cable 2410
T4
Test Distance: 1 Meter
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
+0.7 +0.0
36.3
90.0
Polar
dB
-53.7
Ant
Horiz
+0.8
+0.0
34.5
90.0
-55.5
Horiz
+0.8
+0.0
34.0
90.0
-56.0
Horiz
+1.0
+0.0
32.0
90.0
-58.0
Horiz
+0.8
+0.0
30.6
90.0
-59.4
Horiz
Page 74 of 161
Report No.: MIL05-043
6
192.018M
36.9
7
59.987M
42.8
8
181.504M
35.6
9
113.143M
40.0
10
134.313M
39.3
11
87.025M
39.0
12
88.027M
37.8
13
94.993M
37.8
14
178.857M
33.7
15
179.916M
33.0
16
140.046M
37.0
17
88.462M
35.5
18
135.989M
36.6
19
111.996M
36.7
20
140.399M
35.8
21
176.035M
31.5
22
178.152M
31.2
23
197.972M
31.6
24
178.416M
30.9
25
66.692M
39.5
26
120.023M
34.8
27
144.015M
34.5
-28.9
+16.0
-29.3
+10.7
-28.9
+16.3
-29.2
+12.3
-29.1
+12.8
-29.3
+12.9
-29.3
+13.8
-29.2
+13.7
-28.9
+16.4
-28.9
+16.4
-29.1
+12.8
-29.3
+14.2
-29.1
+12.8
-29.2
+12.3
-29.1
+12.9
-28.9
+16.5
-28.9
+16.4
-28.8
+15.9
-28.9
+16.4
-29.3
+8.7
-29.1
+12.5
-29.1
+12.9
+0.2
+0.3
+1.1
+0.0
25.6
90.0
-64.4
Horiz
+0.1
+0.2
+0.5
+0.0
25.0
90.0
-65.0
Horiz
+0.3
+0.3
+1.0
+0.0
24.6
90.0
-65.4
Horiz
+0.2
+0.3
+0.7
+0.0
24.3
90.0
-65.7
Horiz
+0.2
+0.3
+0.8
+0.0
24.3
90.0
-65.7
Horiz
+0.2
+0.2
+0.6
+0.0
23.6
90.0
-66.4
Horiz
+0.2
+0.2
+0.7
+0.0
23.4
90.0
-66.6
Horiz
+0.2
+0.2
+0.7
+0.0
23.4
90.0
-66.6
Horiz
+0.3
+0.3
+1.0
+0.0
22.8
90.0
-67.2
Horiz
+0.3
+0.3
+1.0
+0.0
22.1
90.0
-67.9
Horiz
+0.2
+0.2
+0.8
+0.0
21.9
90.0
-68.1
Horiz
+0.2
+0.2
+0.7
+0.0
21.5
90.0
-68.5
Horiz
+0.2
+0.2
+0.8
+0.0
21.5
90.0
-68.5
Horiz
+0.2
+0.3
+0.7
+0.0
21.0
90.0
-69.0
Horiz
+0.2
+0.2
+0.8
+0.0
20.8
90.0
-69.2
Horiz
+0.3
+0.3
+1.0
+0.0
20.7
90.0
-69.3
Horiz
+0.3
+0.3
+1.0
+0.0
20.3
90.0
-69.7
Horiz
+0.2
+0.3
+1.0
+0.0
20.2
90.0
-69.8
Horiz
+0.3
+0.3
+1.0
+0.0
20.0
90.0
-70.0
Horiz
+0.2
+0.2
+0.5
+0.0
19.8
90.0
-70.2
Horiz
+0.2
+0.3
+0.8
+0.0
19.5
90.0
-70.5
Horiz
+0.2
+0.2
+0.8
+0.0
19.5
90.0
-70.5
Horiz
Page 75 of 161
Report No.: MIL05-043
28
140.575M
34.2
29
105.998M
34.9
30
160.069M
32.0
-29.1
+12.9
-29.2
+12.2
-29.0
+14.5
+0.2
+0.2
+0.8
+0.0
19.2
90.0
-70.8
Horiz
+0.2
+0.3
+0.7
+0.0
19.1
90.0
-70.9
Horiz
+0.2
+0.3
+0.8
+0.0
18.8
90.0
-71.2
Horiz
Page 76 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Manufacturer
Power Supply
AEMC Instruments
VME Crate
Dawn
Mouse
Dell by Microsoft
Keyboard
Dell
Monitor
Dell
PC
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/19/2005
2:38:59 PM
2
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=8447D OPT 010 AN00686 SN 2944A08591
T3=Cable P05309
T5=Bicon AN732 4-11-05
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
T5
MHz
dBµV
dB
dB
dB
1 95.994M
50.0
-29.2
+0.2
+0.2
+13.4
2 98.999M
50.0
-29.3
+0.2
+0.2
+12.3
3 132.019M
46.9
-29.1
+0.2
+0.3
+12.7
4 40.028M
48.4
-29.4
+0.2
+0.2
+10.6
5 199.976M
41.2
-28.8
+0.2
+0.3
+15.8
T2=3.5' Cable AN 01189
T4=Cable 2410
T4
Test Distance: 1 Meter
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
+0.7 +0.0
35.3
90.0
Polar
dB
-54.7
Ant
Vert
+0.8
+0.0
34.2
90.0
-55.8
Vert
+0.8
+0.0
31.8
90.0
-58.2
Vert
+0.5
+0.0
30.5
90.0
-59.5
Vert
+1.0
+0.0
29.7
90.0
-60.3
Vert
Page 77 of 161
Report No.: MIL05-043
6
32.990M
45.6
7
41.457M
45.9
8
40.399M
45.9
9
36.059M
43.4
10
159.981M
38.9
11
181.504M
36.7
12
180.004M
36.3
13
144.015M
39.8
14
120.023M
39.5
15
191.995M
34.4
16
177.799M
33.4
17
181.768M
33.3
18
178.857M
32.7
19
34.048M
38.1
20
60.030M
39.0
21
95.515M
35.5
22
178.240M
31.8
23
100.000M
36.8
24
175.946M
31.2
25
94.949M
34.7
26
114.025M
35.7
-29.4
+12.2
-29.4
+10.7
-29.4
+10.6
-29.4
+11.3
-29.0
+14.5
-28.9
+16.3
-28.9
+16.4
-29.1
+12.9
-29.1
+12.5
-28.9
+16.0
-28.9
+16.4
-28.9
+16.3
-28.9
+16.4
-29.4
+11.8
-29.3
+10.7
-29.2
+13.5
-28.9
+16.4
-29.3
+12.0
-28.9
+16.5
-29.2
+13.7
-29.2
+12.4
+0.2
+0.1
+0.4
+0.0
29.1
90.0
-60.9
Vert
+0.2
+0.2
+0.5
+0.0
28.1
90.0
-61.9
Vert
+0.2
+0.2
+0.5
+0.0
28.0
90.0
-62.0
Vert
+0.3
+0.1
+0.4
+0.0
26.1
90.0
-63.9
Vert
+0.2
+0.3
+0.8
+0.0
25.7
90.0
-64.3
Vert
+0.3
+0.3
+1.0
+0.0
25.7
90.0
-64.3
Vert
+0.3
+0.3
+1.0
+0.0
25.4
90.0
-64.6
Vert
+0.2
+0.2
+0.8
+0.0
24.8
90.0
-65.2
Vert
+0.2
+0.3
+0.8
+0.0
24.2
90.0
-65.8
Vert
+0.2
+0.3
+1.1
+0.0
23.1
90.0
-66.9
Vert
+0.3
+0.3
+1.0
+0.0
22.5
90.0
-67.5
Vert
+0.3
+0.3
+1.0
+0.0
22.3
90.0
-67.7
Vert
+0.3
+0.3
+1.0
+0.0
21.8
90.0
-68.2
Vert
+0.3
+0.1
+0.4
+0.0
21.3
90.0
-68.7
Vert
+0.1
+0.2
+0.5
+0.0
21.2
90.0
-68.8
Vert
+0.2
+0.2
+0.7
+0.0
20.9
90.0
-69.1
Vert
+0.3
+0.3
+1.0
+0.0
20.9
90.0
-69.1
Vert
+0.2
+0.2
+0.8
+0.0
20.7
90.0
-69.3
Vert
+0.3
+0.3
+1.0
+0.0
20.4
90.0
-69.6
Vert
+0.2
+0.2
+0.7
+0.0
20.3
90.0
-69.7
Vert
+0.2
+0.3
+0.7
+0.0
20.1
90.0
-69.9
Vert
Page 78 of 161
Report No.: MIL05-043
27
99.956M
36.0
28
177.181M
30.8
29
140.487M
34.6
30
133.254M
34.4
-29.3
+12.0
-28.9
+16.4
-29.1
+12.9
-29.1
+12.7
+0.2
+0.2
+0.8
+0.0
19.9
90.0
-70.1
Vert
+0.3
+0.3
+1.0
+0.0
19.9
90.0
-70.1
Vert
+0.2
+0.2
+0.8
+0.0
19.6
90.0
-70.4
Vert
+0.2
+0.3
+0.8
+0.0
19.3
90.0
-70.7
Vert
Page 79 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
82840
Radiated Scan
Date:
Time:
Sequence#:
Tested By:
10/19/2005
1:37:48 PM
0
A. Brar
Equipment Under Test (* = EUT):
Function
Manufacturer
Model #
S/N
Support Devices:
Function
Model #
S/N
Manufacturer
Test Conditions / Notes:
Path Check Sweep. Signal at 200.00MHz. 90 (spec limit) - 6dB - 15.8 (Antenna Factor) = 68.2dBuV signal level.
Transducer Legend:
T1=8447D OPT 010 AN00686 SN 2944A08591
T3=Cable P05309
T5=Bicon AN732 4-11-05
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
T5
MHz
dBµV
dB
dB
dB
1 199.976M
94.8
-28.8
+0.2
+0.3
+15.8
2 199.670M
31.0
-28.8
+0.2
+0.3
+15.8
3 188.210M
28.9
-28.9
+0.2
+0.3
+16.1
4 186.002M
28.5
-28.9
+0.3
+0.3
+16.2
5 189.354M
28.7
-28.9
+0.2
+0.3
+16.1
6 188.207M
28.6
-28.9
+0.2
+0.3
+16.1
7 188.208M
28.4
-28.9
+0.2
+0.3
+16.1
8 188.210M
28.4
-28.9
+0.2
+0.3
+16.1
9 193.209M
28.4
-28.9
+0.2
+0.3
+16.0
T2=3.5' Cable AN 01189
T4=Cable 2410
T4
Test Distance: None
Dist
Corr
Spec
dB
Table dBµV/m dBµV/m
+1.0 +0.0
83.3
90.0
Margin
Polar
dB
-6.7
Ant
None
+1.0
+0.0
19.5
90.0
-70.5
None
+1.1
+0.0
17.7
90.0
-72.3
None
+1.1
+0.0
17.5
90.0
-72.5
None
+1.1
+0.0
17.5
90.0
-72.5
None
+1.1
+0.0
17.4
90.0
-72.6
None
+1.1
+0.0
17.2
90.0
-72.8
None
+1.1
+0.0
17.2
90.0
-72.8
None
+1.1
+0.0
17.1
90.0
-72.9
None
Page 80 of 161
Report No.: MIL05-043
10
178.945M
27.9
11
188.208M
28.2
12
199.446M
28.5
13
181.151M
27.9
14
189.566M
28.1
15
189.707M
28.1
16
190.096M
28.1
17
190.427M
28.1
18
199.552M
28.4
19
188.210M
27.9
20
183.356M
27.6
21
191.841M
27.9
22
188.207M
27.6
23
188.210M
27.6
24
189.672M
27.6
25
188.207M
27.5
26
193.834M
27.6
27
190.745M
27.5
-28.9
+16.4
-28.9
+16.1
-28.8
+15.8
-28.9
+16.3
-28.9
+16.1
-28.9
+16.1
-28.9
+16.1
-28.9
+16.1
-28.8
+15.8
-28.9
+16.1
-28.9
+16.3
-28.9
+16.0
-28.9
+16.1
-28.9
+16.1
-28.9
+16.1
-28.9
+16.1
-28.9
+16.0
-28.9
+16.0
+0.3
+0.3
+1.0
+0.0
17.0
90.0
-73.0
None
+0.2
+0.3
+1.1
+0.0
17.0
90.0
-73.0
None
+0.2
+0.3
+1.0
+0.0
17.0
90.0
-73.0
None
+0.3
+0.3
+1.0
+0.0
16.9
90.0
-73.1
None
+0.2
+0.3
+1.1
+0.0
16.9
90.0
-73.1
None
+0.2
+0.3
+1.1
+0.0
16.9
90.0
-73.1
None
+0.2
+0.3
+1.1
+0.0
16.9
90.0
-73.1
None
+0.2
+0.3
+1.1
+0.0
16.9
90.0
-73.1
None
+0.2
+0.3
+1.0
+0.0
16.9
90.0
-73.1
None
+0.2
+0.3
+1.1
+0.0
16.7
90.0
-73.3
None
+0.3
+0.3
+1.0
+0.0
16.6
90.0
-73.4
None
+0.2
+0.3
+1.1
+0.0
16.6
90.0
-73.4
None
+0.2
+0.3
+1.1
+0.0
16.4
90.0
-73.6
None
+0.2
+0.3
+1.1
+0.0
16.4
90.0
-73.6
None
+0.2
+0.3
+1.1
+0.0
16.4
90.0
-73.6
None
+0.2
+0.3
+1.1
+0.0
16.3
90.0
-73.7
None
+0.2
+0.3
+1.1
+0.0
16.3
90.0
-73.7
None
+0.2
+0.3
+1.1
+0.0
16.2
90.0
-73.8
None
Page 81 of 161
Report No.: MIL05-043
28
193.268M
27.5
29
194.023M
27.5
30
198.573M
27.7
-28.9
+16.0
-28.9
+16.0
-28.8
+15.8
+0.2
+0.3
+1.1
+0.0
16.2
90.0
-73.8
None
+0.2
+0.3
+1.1
+0.0
16.2
90.0
-73.8
None
+0.2
+0.3
+1.0
+0.0
16.2
90.0
-73.8
None
Page 82 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
82840
Radiated Scan
Date:
Time:
Sequence#:
Tested By:
10/19/2005
1:42:31 PM
0
A. Brar
Equipment Under Test (* = EUT):
Function
Manufacturer
Model #
S/N
Support Devices:
Function
Model #
S/N
Manufacturer
Test Conditions / Notes:
Path Check Sweep. Signal at 1000.00MHz. 90 (spec limit) - 6dB - 22.7 (Antenna Factor) = 61.3dBuV signal level.
Transducer Legend:
T1=8447D OPT 010 AN00686 SN 2944A08591
T3=Cable P05309
T5=SAS-570 Horn Antenna - 2525
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
T5
MHz
dBµV
dB
dB
dB
1 1000.000M
86.0
-29.1
+0.5
+0.8
+22.8
2 499.900M
54.9
-29.7
+0.4
+0.5
+16.5
3 292.599M
28.3
-28.4
+0.3
+0.4
+12.5
4 286.099M
28.1
-28.4
+0.3
+0.4
+12.4
5 242.900M
28.8
-28.6
+0.3
+0.4
+11.7
6 282.299M
27.6
-28.5
+0.3
+0.4
+12.3
7 283.599M
27.6
-28.5
+0.3
+0.4
+12.3
8 261.099M
28.1
-28.5
+0.3
+0.3
+11.9
9 275.099M
27.6
-28.5
+0.3
+0.4
+12.1
T2=3.5' Cable AN 01189
T4=Cable 2410
T4
Test Distance: None
Dist
Corr
Spec
dB
Table dBµV/m dBµV/m
+2.9 +0.0
83.9
90.0
Margin
Polar
dB
-6.1
Ant
None
+1.8
+0.0
44.4
90.0
-45.6
None
+1.5
+0.0
14.6
90.0
-75.4
None
+1.4
+0.0
14.2
90.0
-75.8
None
+1.2
+0.0
13.8
90.0
-76.2
None
+1.3
+0.0
13.4
90.0
-76.6
None
+1.3
+0.0
13.4
90.0
-76.6
None
+1.2
+0.0
13.3
90.0
-76.7
None
+1.3
+0.0
13.2
90.0
-76.8
None
Page 83 of 161
Report No.: MIL05-043
10
282.599M
27.4
11
270.299M
27.5
12
271.599M
27.5
13
279.599M
27.3
14
278.399M
27.2
15
209.100M
29.3
16
264.099M
27.5
17
266.099M
27.4
18
273.299M
27.3
19
273.899M
27.3
20
276.899M
27.1
21
222.600M
28.2
22
225.600M
28.1
23
264.699M
27.1
24
247.100M
27.3
25
220.200M
27.9
26
299.999M
25.4
27
214.100M
28.2
-28.5
+12.3
-28.5
+12.1
-28.5
+12.1
-28.5
+12.2
-28.5
+12.2
-28.8
+10.7
-28.5
+12.0
-28.5
+12.0
-28.5
+12.1
-28.5
+12.1
-28.5
+12.2
-28.7
+11.3
-28.6
+11.3
-28.5
+12.0
-28.6
+11.8
-28.7
+11.2
-28.5
+12.7
-28.8
+10.9
+0.3
+0.4
+1.3
+0.0
13.2
90.0
-76.8
None
+0.3
+0.3
+1.3
+0.0
13.0
90.0
-77.0
None
+0.3
+0.3
+1.3
+0.0
13.0
90.0
-77.0
None
+0.3
+0.4
+1.3
+0.0
13.0
90.0
-77.0
None
+0.3
+0.4
+1.3
+0.0
12.9
90.0
-77.1
None
+0.2
+0.3
+1.1
+0.0
12.8
90.0
-77.2
None
+0.3
+0.3
+1.2
+0.0
12.8
90.0
-77.2
None
+0.3
+0.3
+1.3
+0.0
12.8
90.0
-77.2
None
+0.3
+0.3
+1.3
+0.0
12.8
90.0
-77.2
None
+0.3
+0.3
+1.3
+0.0
12.8
90.0
-77.2
None
+0.3
+0.4
+1.3
+0.0
12.8
90.0
-77.2
None
+0.2
+0.3
+1.1
+0.0
12.4
90.0
-77.6
None
+0.2
+0.3
+1.1
+0.0
12.4
90.0
-77.6
None
+0.3
+0.3
+1.2
+0.0
12.4
90.0
-77.6
None
+0.3
+0.3
+1.2
+0.0
12.3
90.0
-77.7
None
+0.2
+0.3
+1.1
+0.0
12.0
90.0
-78.0
None
+0.3
+0.4
+1.7
+0.0
12.0
90.0
-78.0
None
+0.2
+0.3
+1.1
+0.0
11.9
90.0
-78.1
None
Page 84 of 161
Report No.: MIL05-043
28
219.600M
27.7
29
215.500M
27.9
30
214.900M
27.9
-28.7
+11.2
-28.7
+11.0
-28.8
+11.0
+0.2
+0.3
+1.1
+0.0
11.8
90.0
-78.2
None
+0.2
+0.3
+1.1
+0.0
11.8
90.0
-78.2
None
+0.2
+0.3
+1.1
+0.0
11.7
90.0
-78.3
None
Page 85 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/19/2005
2:57:09 PM
5
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=8447D OPT 010 AN00686 SN 2944A08591
T3=Cable P05309
T5=SAS-570 Horn Antenna - 2525
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
T5
MHz
dBµV
dB
dB
dB
1 263.964M
54.2
-28.5
+0.3
+0.3
+12.0
2 240.040M
52.9
-28.6
+0.3
+0.4
+11.7
3 266.667M
50.4
-28.5
+0.3
+0.3
+12.0
4 528.028M
42.8
-29.8
+0.4
+0.6
+16.9
5 200.100M
49.4
-28.8
+0.2
+0.3
+10.3
T2=3.5' Cable AN 01189
T4=Cable 2410
T4
Test Distance: 1 Meter
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
+1.2 +0.0
39.5
90.0
Polar
dB
-50.5
Ant
Horiz
+1.2
+0.0
37.9
90.0
-52.1
Horiz
+1.3
+0.0
35.8
90.0
-54.2
Horiz
+1.9
+0.0
32.8
90.0
-57.2
Horiz
+1.0
+0.0
32.4
90.0
-57.6
Horiz
Page 86 of 161
Report No.: MIL05-043
6
479.980M
41.0
7
675.175M
39.1
8
600.000M
36.2
9
459.960M
38.0
10
777.277M
33.5
11
551.952M
37.3
12
979.743M
29.4
13
431.932M
39.1
14
603.203M
34.8
15
947.868M
29.2
16
991.063M
28.1
17
983.715M
28.2
18
300.000M
38.7
19
975.870M
28.3
20
983.516M
28.1
21
312.012M
38.4
22
767.967M
31.9
23
957.698M
28.4
24
967.231M
28.4
25
969.018M
28.3
26
976.962M
28.2
-29.6
+17.2
-29.8
+17.9
-30.0
+18.1
-29.4
+15.7
-29.2
+19.0
-30.0
+16.2
-29.2
+22.2
-29.2
+14.1
-30.0
+18.0
-29.1
+21.6
-29.1
+22.5
-29.2
+22.3
-28.5
+12.7
-29.2
+22.1
-29.2
+22.3
-28.4
+13.1
-29.3
+18.9
-29.2
+21.8
-29.2
+21.9
-29.2
+22.0
-29.2
+22.1
+0.3
+0.5
+1.8
+0.0
31.2
90.0
-58.8
Horiz
+0.5
+0.7
+2.3
+0.0
30.7
90.0
-59.3
Horiz
+0.5
+0.5
+2.2
+0.0
27.5
90.0
-62.5
Horiz
+0.3
+0.5
+1.9
+0.0
27.0
90.0
-63.0
Horiz
+0.5
+0.6
+2.5
+0.0
26.9
90.0
-63.1
Horiz
+0.4
+0.6
+2.0
+0.0
26.5
90.0
-63.5
Horiz
+0.6
+0.7
+2.8
+0.0
26.5
90.0
-63.5
Horiz
+0.3
+0.4
+1.7
+0.0
26.4
90.0
-63.6
Horiz
+0.5
+0.5
+2.2
+0.0
26.0
90.0
-64.0
Horiz
+0.6
+0.8
+2.9
+0.0
26.0
90.0
-64.0
Horiz
+0.5
+0.8
+2.9
+0.0
25.7
90.0
-64.3
Horiz
+0.6
+0.7
+2.8
+0.0
25.4
90.0
-64.6
Horiz
+0.3
+0.4
+1.7
+0.0
25.3
90.0
-64.7
Horiz
+0.6
+0.7
+2.8
+0.0
25.3
90.0
-64.7
Horiz
+0.6
+0.7
+2.8
+0.0
25.3
90.0
-64.7
Horiz
+0.3
+0.4
+1.4
+0.0
25.2
90.0
-64.8
Horiz
+0.5
+0.7
+2.5
+0.0
25.2
90.0
-64.8
Horiz
+0.6
+0.7
+2.9
+0.0
25.2
90.0
-64.8
Horiz
+0.6
+0.7
+2.8
+0.0
25.2
90.0
-64.8
Horiz
+0.6
+0.7
+2.8
+0.0
25.2
90.0
-64.8
Horiz
+0.6
+0.7
+2.8
+0.0
25.2
90.0
-64.8
Horiz
Page 87 of 161
Report No.: MIL05-043
27
996.326M
27.4
28
452.853M
36.5
29
580.080M
34.4
30
971.600M
28.0
-29.1
+22.7
-29.3
+15.3
-30.0
+17.7
-29.2
+22.0
+0.5
+0.8
+2.9
+0.0
25.2
90.0
-64.8
Horiz
+0.3
+0.5
+1.8
+0.0
25.1
90.0
-64.9
Horiz
+0.4
+0.6
+2.0
+0.0
25.1
90.0
-64.9
Horiz
+0.6
+0.7
+2.8
+0.0
24.9
90.0
-65.1
Horiz
Page 88 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/19/2005
2:52:46 PM
4
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=8447D OPT 010 AN00686 SN 2944A08591
T3=Cable P05309
T5=SAS-570 Horn Antenna - 2525
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
T5
MHz
dBµV
dB
dB
dB
1 240.040M
56.8
-28.6
+0.3
+0.4
+11.7
2 600.000M
44.1
-30.0
+0.5
+0.5
+18.1
3 603.203M
42.9
-30.0
+0.5
+0.5
+18.0
4 479.980M
41.7
-29.6
+0.3
+0.5
+17.2
5 336.036M
44.6
-28.5
+0.4
+0.4
+13.2
T2=3.5' Cable AN 01189
T4=Cable 2410
T4
Test Distance: 1 Meter
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
+1.2 +0.0
41.8
90.0
Polar
dB
-48.2
Ant
Vert
+2.2
+0.0
35.4
90.0
-54.6
Vert
+2.2
+0.0
34.1
90.0
-55.9
Vert
+1.8
+0.0
31.9
90.0
-58.1
Vert
+1.5
+0.0
31.6
90.0
-58.4
Vert
Page 89 of 161
Report No.: MIL05-043
6
559.960M
40.1
7
312.012M
41.9
8
200.100M
45.2
9
600.400M
36.9
10
959.982M
31.0
11
432.032M
40.3
12
551.952M
38.4
13
767.967M
33.6
14
528.028M
36.8
15
620.220M
36.1
16
989.971M
28.6
17
863.963M
31.4
18
825.024M
31.9
19
979.743M
28.8
20
992.950M
28.0
21
955.216M
28.8
22
973.487M
28.5
23
980.140M
28.3
24
890.990M
30.2
25
945.584M
28.5
26
994.042M
27.5
27
953.230M
28.4
-30.0
+16.1
-28.4
+13.1
-28.8
+10.3
-30.0
+18.1
-29.2
+21.8
-29.2
+14.1
-30.0
+16.2
-29.3
+18.9
-29.8
+16.9
-30.0
+17.5
-29.1
+22.5
-29.1
+19.7
-29.2
+19.4
-29.2
+22.2
-29.1
+22.6
-29.2
+21.7
-29.2
+22.1
-29.2
+22.2
-29.1
+20.3
-29.1
+21.5
-29.1
+22.6
-29.2
+21.7
+0.4
+0.6
+2.0
+0.0
29.2
90.0
-60.8
Vert
+0.3
+0.4
+1.4
+0.0
28.7
90.0
-61.3
Vert
+0.2
+0.3
+1.0
+0.0
28.2
90.0
-61.8
Vert
+0.5
+0.5
+2.2
+0.0
28.2
90.0
-61.8
Vert
+0.6
+0.7
+2.9
+0.0
27.8
90.0
-62.2
Vert
+0.3
+0.4
+1.7
+0.0
27.6
90.0
-62.4
Vert
+0.4
+0.6
+2.0
+0.0
27.6
90.0
-62.4
Vert
+0.5
+0.7
+2.5
+0.0
26.9
90.0
-63.1
Vert
+0.4
+0.6
+1.9
+0.0
26.8
90.0
-63.2
Vert
+0.4
+0.5
+2.2
+0.0
26.7
90.0
-63.3
Vert
+0.5
+0.8
+2.9
+0.0
26.2
90.0
-63.8
Vert
+0.6
+0.7
+2.7
+0.0
26.0
90.0
-64.0
Vert
+0.5
+0.6
+2.7
+0.0
25.9
90.0
-64.1
Vert
+0.6
+0.7
+2.8
+0.0
25.9
90.0
-64.1
Vert
+0.5
+0.8
+2.9
+0.0
25.7
90.0
-64.3
Vert
+0.6
+0.7
+2.9
+0.0
25.5
90.0
-64.5
Vert
+0.6
+0.7
+2.8
+0.0
25.5
90.0
-64.5
Vert
+0.6
+0.7
+2.8
+0.0
25.4
90.0
-64.6
Vert
+0.5
+0.7
+2.7
+0.0
25.3
90.0
-64.7
Vert
+0.6
+0.8
+2.9
+0.0
25.2
90.0
-64.8
Vert
+0.5
+0.8
+2.9
+0.0
25.2
90.0
-64.8
Vert
+0.6
+0.7
+2.9
+0.0
25.1
90.0
-64.9
Vert
Page 90 of 161
Report No.: MIL05-043
28
957.798M
28.3
29
972.593M
28.1
30
931.483M
28.7
-29.2
+21.8
-29.2
+22.1
-29.1
+21.2
+0.6
+0.7
+2.9
+0.0
25.1
90.0
-64.9
Vert
+0.6
+0.7
+2.8
+0.0
25.1
90.0
-64.9
Vert
+0.6
+0.8
+2.8
+0.0
25.0
90.0
-65.0
Vert
Page 91 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Test Equipment:
Function
SA - E4446A
S/N
US44300408
Calibration Date
01/13/2005
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/20/2005
10:52:06 AM
11
A. Brar
Cal Due Date
01/13/2007
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
Asset #
02668
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 1195.340M
55.9 +24.5
-39.7
+1.5
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+1.4 +0.0
43.6
90.0
-46.4
Polar
Ant
Horiz
2 1199.709M
53.4
+24.5
-39.7
+1.5
+1.4
+0.0
41.1
90.0
-48.9
Horiz
3 1022.336M
54.1
+24.0
-40.5
+1.4
+1.3
+0.0
40.3
90.0
-49.7
Horiz
4 1061.345M
53.8
+24.1
-40.3
+1.4
+1.3
+0.0
40.3
90.0
-49.7
Horiz
Page 92 of 161
Report No.: MIL05-043
5 1191.335M
52.0
+24.5
-39.7
+1.5
+1.4
+0.0
39.7
90.0
-50.3
Horiz
6 1051.593M
53.2
+24.1
-40.4
+1.4
+1.3
+0.0
39.6
90.0
-50.4
Horiz
7 1482.164M
49.6
+25.3
-38.7
+1.7
+1.6
+0.0
39.5
90.0
-50.5
Horiz
8 1328.044M
50.6
+24.9
-39.2
+1.6
+1.5
+0.0
39.4
90.0
-50.6
Horiz
9 1162.027M
51.9
+24.4
-39.9
+1.5
+1.4
+0.0
39.3
90.0
-50.7
Horiz
10 1326.588M
50.5
+24.9
-39.2
+1.6
+1.5
+0.0
39.3
90.0
-50.7
Horiz
11 1475.844M
49.4
+25.2
-38.7
+1.7
+1.6
+0.0
39.2
90.0
-50.8
Horiz
12 1376.830M
50.0
+25.0
-39.0
+1.6
+1.5
+0.0
39.1
90.0
-50.9
Horiz
13 1536.096M
48.7
+25.5
-38.6
+1.7
+1.7
+0.0
39.0
90.0
-51.0
Horiz
14 1099.096M
51.8
+24.2
-40.1
+1.5
+1.4
+0.0
38.8
90.0
-51.2
Horiz
15 1358.712M
49.8
+25.0
-39.1
+1.6
+1.5
+0.0
38.8
90.0
-51.2
Horiz
16 1501.546M
48.8
+25.3
-38.6
+1.7
+1.6
+0.0
38.8
90.0
-51.2
Horiz
17 1546.208M
48.3
+25.6
-38.5
+1.7
+1.7
+0.0
38.8
90.0
-51.2
Horiz
18 1145.183M
51.3
+24.4
-39.9
+1.5
+1.4
+0.0
38.7
90.0
-51.3
Horiz
19 1189.151M
51.0
+24.5
-39.7
+1.5
+1.4
+0.0
38.7
90.0
-51.3
Horiz
20 1358.080M
49.6
+25.0
-39.1
+1.6
+1.5
+0.0
38.6
90.0
-51.4
Horiz
21 1483.850M
48.7
+25.3
-38.7
+1.7
+1.6
+0.0
38.6
90.0
-51.4
Horiz
22 1519.242M
48.5
+25.4
-38.6
+1.7
+1.6
+0.0
38.6
90.0
-51.4
Horiz
23 1166.396M
51.0
+24.4
-39.8
+1.5
+1.4
+0.0
38.5
90.0
-51.5
Horiz
24 1250.315M
50.3
+24.7
-39.5
+1.5
+1.5
+0.0
38.5
90.0
-51.5
Horiz
25 1442.348M
48.9
+25.2
-38.8
+1.6
+1.6
+0.0
38.5
90.0
-51.5
Horiz
26 1519.664M
48.4
+25.4
-38.6
+1.7
+1.6
+0.0
38.5
90.0
-51.5
Horiz
Page 93 of 161
Report No.: MIL05-043
27 1153.519M
51.0
+24.4
-39.9
+1.5
+1.4
+0.0
38.4
90.0
-51.6
Horiz
28 1168.945M
50.9
+24.4
-39.8
+1.5
+1.4
+0.0
38.4
90.0
-51.6
Horiz
29 1505.759M
48.3
+25.3
-38.6
+1.7
+1.6
+0.0
38.3
90.0
-51.7
Horiz
30 1513.976M
48.2
+25.4
-38.6
+1.7
+1.6
+0.0
38.3
90.0
-51.7
Horiz
Page 94 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/20/2005
8:57:42 AM
6
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 1084.782M
56.5 +24.2
-40.2
+1.5
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+1.4 +0.0
43.4
90.0
-46.6
Polar
Ant
Vert
2 1133.071M
53.6
+24.3
-40.0
+1.5
+1.4
+0.0
40.8
90.0
-49.2
Vert
3 1161.845M
53.1
+24.4
-39.9
+1.5
+1.4
+0.0
40.5
90.0
-49.5
Vert
4 1327.680M
51.0
+24.9
-39.2
+1.6
+1.5
+0.0
39.8
90.0
-50.2
Vert
5 1333.688M
50.9
+24.9
-39.2
+1.6
+1.5
+0.0
39.7
90.0
-50.3
Vert
6 1377.462M
50.4
+25.0
-39.0
+1.6
+1.5
+0.0
39.5
90.0
-50.5
Vert
Page 95 of 161
Report No.: MIL05-043
7 1359.976M
50.4
+25.0
-39.1
+1.6
+1.5
+0.0
39.4
90.0
-50.6
Vert
8 1194.612M
51.6
+24.5
-39.7
+1.5
+1.4
+0.0
39.3
90.0
-50.7
Vert
9 1364.611M
50.1
+25.0
-39.1
+1.6
+1.5
+0.0
39.1
90.0
-50.9
Vert
10 1500.703M
49.1
+25.3
-38.6
+1.7
+1.6
+0.0
39.1
90.0
-50.9
Vert
11 1536.096M
48.8
+25.5
-38.6
+1.7
+1.7
+0.0
39.1
90.0
-50.9
Vert
12 1000.157M
53.0
+23.9
-40.6
+1.4
+1.3
+0.0
39.0
90.0
-51.0
Vert
13 1361.240M
50.0
+25.0
-39.1
+1.6
+1.5
+0.0
39.0
90.0
-51.0
Vert
14 1433.710M
49.5
+25.1
-38.8
+1.6
+1.6
+0.0
39.0
90.0
-51.0
Vert
15 1539.888M
48.7
+25.5
-38.6
+1.7
+1.7
+0.0
39.0
90.0
-51.0
Vert
16 1114.196M
51.8
+24.3
-40.1
+1.5
+1.4
+0.0
38.9
90.0
-51.1
Vert
17 1518.610M
48.8
+25.4
-38.6
+1.7
+1.6
+0.0
38.9
90.0
-51.1
Vert
18 1352.392M
49.9
+24.9
-39.1
+1.6
+1.5
+0.0
38.8
90.0
-51.2
Vert
19 1408.219M
49.5
+25.1
-38.9
+1.6
+1.5
+0.0
38.8
90.0
-51.2
Vert
20 1539.045M
48.5
+25.5
-38.6
+1.7
+1.7
+0.0
38.8
90.0
-51.2
Vert
21 1330.411M
49.9
+24.9
-39.2
+1.6
+1.5
+0.0
38.7
90.0
-51.3
Vert
22 1398.318M
49.4
+25.1
-38.9
+1.6
+1.5
+0.0
38.7
90.0
-51.3
Vert
23 1523.456M
48.6
+25.4
-38.6
+1.7
+1.6
+0.0
38.7
90.0
-51.3
Vert
24 1527.248M
48.4
+25.5
-38.6
+1.7
+1.7
+0.0
38.7
90.0
-51.3
Vert
25 1530.829M
48.4
+25.5
-38.6
+1.7
+1.7
+0.0
38.7
90.0
-51.3
Vert
26 1045.615M
52.2
+24.1
-40.4
+1.4
+1.3
+0.0
38.6
90.0
-51.4
Vert
27 1210.267M
50.8
+24.6
-39.7
+1.5
+1.4
+0.0
38.6
90.0
-51.4
Vert
Page 96 of 161
Report No.: MIL05-043
28 1369.035M
49.6
+25.0
-39.1
+1.6
+1.5
+0.0
38.6
90.0
-51.4
Vert
29 1316.394M
49.8
+24.8
-39.2
+1.6
+1.5
+0.0
38.5
90.0
-51.5
Vert
30 1510.394M
48.4
+25.4
-38.6
+1.7
+1.6
+0.0
38.5
90.0
-51.5
Vert
Page 97 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/20/2005
11:45:23 AM
15
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 1597.441M
22.5 +25.8
-38.5
+1.7
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+1.7 +0.0
13.2
14.0
-0.8
Polar
Ant
Horiz
2 1587.883M
22.2
+25.8
-38.5
+1.7
+1.7
+0.0
12.9
14.0
-1.1
Horiz
3 1598.179M
22.0
+25.8
-38.5
+1.7
+1.7
+0.0
12.7
14.0
-1.3
Horiz
4 1553.051M
22.1
+25.6
-38.5
+1.7
+1.7
+0.0
12.6
14.0
-1.4
Horiz
5 1595.423M
21.8
+25.8
-38.5
+1.7
+1.7
+0.0
12.5
14.0
-1.5
Horiz
6 1586.342M
21.7
+25.8
-38.5
+1.7
+1.7
+0.0
12.4
14.0
-1.6
Horiz
Page 98 of 161
Report No.: MIL05-043
7 1597.883M
21.7
+25.8
-38.5
+1.7
+1.7
+0.0
12.4
14.0
-1.6
Horiz
8 1576.886M
21.7
+25.7
-38.5
+1.7
+1.7
+0.0
12.3
14.0
-1.7
Horiz
9 1579.021M
21.7
+25.7
-38.5
+1.7
+1.7
+0.0
12.3
14.0
-1.7
Horiz
10 1596.856M
21.6
+25.8
-38.5
+1.7
+1.7
+0.0
12.3
14.0
-1.7
Horiz
11 1594.183M
21.5
+25.8
-38.5
+1.7
+1.7
+0.0
12.2
14.0
-1.8
Horiz
12 1599.190M
21.5
+25.8
-38.5
+1.7
+1.7
+0.0
12.2
14.0
-1.8
Horiz
13 1555.102M
21.6
+25.6
-38.5
+1.7
+1.7
+0.0
12.1
14.0
-1.9
Horiz
14 1574.766M
21.5
+25.7
-38.5
+1.7
+1.7
+0.0
12.1
14.0
-1.9
Horiz
15 1582.060M
21.5
+25.7
-38.5
+1.7
+1.7
+0.0
12.1
14.0
-1.9
Horiz
16 1589.820M
21.4
+25.8
-38.5
+1.7
+1.7
+0.0
12.1
14.0
-1.9
Horiz
17 1596.387M
21.4
+25.8
-38.5
+1.7
+1.7
+0.0
12.1
14.0
-1.9
Horiz
18 1598.304M
21.4
+25.8
-38.5
+1.7
+1.7
+0.0
12.1
14.0
-1.9
Horiz
19 1572.219M
21.4
+25.7
-38.5
+1.7
+1.7
+0.0
12.0
14.0
-2.0
Horiz
20 1574.775M
21.4
+25.7
-38.5
+1.7
+1.7
+0.0
12.0
14.0
-2.0
Horiz
21 1579.868M
21.4
+25.7
-38.5
+1.7
+1.7
+0.0
12.0
14.0
-2.0
Horiz
22 1588.297M
21.3
+25.8
-38.5
+1.7
+1.7
+0.0
12.0
14.0
-2.0
Horiz
23 1558.054M
21.4
+25.6
-38.5
+1.7
+1.7
+0.0
11.9
14.0
-2.1
Horiz
24 1559.970M
21.4
+25.6
-38.5
+1.7
+1.7
+0.0
11.9
14.0
-2.1
Horiz
25 1573.246M
21.3
+25.7
-38.5
+1.7
+1.7
+0.0
11.9
14.0
-2.1
Horiz
26 1590.919M
21.2
+25.8
-38.5
+1.7
+1.7
+0.0
11.9
14.0
-2.1
Horiz
27 1597.324M
21.2
+25.8
-38.5
+1.7
+1.7
+0.0
11.9
14.0
-2.1
Horiz
Page 99 of 161
Report No.: MIL05-043
28 1570.799M
21.2
+25.7
-38.5
+1.7
+1.7
+0.0
11.8
14.0
-2.2
Horiz
29 1579.925M
21.2
+25.7
-38.5
+1.7
+1.7
+0.0
11.8
14.0
-2.2
Horiz
30 1591.552M
21.1
+25.8
-38.5
+1.7
+1.7
+0.0
11.8
14.0
-2.2
Horiz
Page 100 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz 1KHz RBW
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/20/2005
1:29:39 PM
19
A. Brar
Model #
SIU
S/N
GLAT 2508
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber. Foil wrapped around J7. Foil from
top of the unit to the copper table.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 1552.897M
22.9 +25.6
-38.5
+1.7
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+1.7 +0.0
13.4
14.0
-0.6
Polar
Ant
Vert
2 1584.213M
20.4
+25.8
-38.5
+1.7
+1.7
+0.0
11.1
14.0
-2.9
Vert
3 1597.442M
20.3
+25.8
-38.5
+1.7
+1.7
+0.0
11.0
14.0
-3.0
Vert
4 1582.952M
19.8
+25.7
-38.5
+1.7
+1.7
+0.0
10.4
14.0
-3.6
Vert
5 1562.915M
18.7
+25.6
-38.5
+1.7
+1.7
+0.0
9.2
14.0
-4.8
Vert
Page 101 of 161
Report No.: MIL05-043
6 1595.277M
18.5
+25.8
-38.5
+1.7
+1.7
+0.0
9.2
14.0
-4.8
Vert
7 1592.687M
18.3
+25.8
-38.5
+1.7
+1.7
+0.0
9.0
14.0
-5.0
Vert
8 1597.490M
18.2
+25.8
-38.5
+1.7
+1.7
+0.0
8.9
14.0
-5.1
Vert
9 1572.398M
17.9
+25.7
-38.5
+1.7
+1.7
+0.0
8.5
14.0
-5.5
Vert
10 1582.655M
17.9
+25.7
-38.5
+1.7
+1.7
+0.0
8.5
14.0
-5.5
Vert
11 1592.479M
17.8
+25.8
-38.5
+1.7
+1.7
+0.0
8.5
14.0
-5.5
Vert
12 1592.503M
17.7
+25.8
-38.5
+1.7
+1.7
+0.0
8.4
14.0
-5.6
Vert
13 1559.988M
17.8
+25.6
-38.5
+1.7
+1.7
+0.0
8.3
14.0
-5.7
Vert
14 1592.148M
17.6
+25.8
-38.5
+1.7
+1.7
+0.0
8.3
14.0
-5.7
Vert
15 1550.077M
17.7
+25.6
-38.5
+1.7
+1.7
+0.0
8.2
14.0
-5.8
Vert
16 1575.157M
17.5
+25.7
-38.5
+1.7
+1.7
+0.0
8.1
14.0
-5.9
Vert
17 1588.289M
17.4
+25.8
-38.5
+1.7
+1.7
+0.0
8.1
14.0
-5.9
Vert
18 1577.941M
17.4
+25.7
-38.5
+1.7
+1.7
+0.0
8.0
14.0
-6.0
Vert
19 1592.238M
17.3
+25.8
-38.5
+1.7
+1.7
+0.0
8.0
14.0
-6.0
Vert
20 1550.598M
17.4
+25.6
-38.5
+1.7
+1.7
+0.0
7.9
14.0
-6.1
Vert
21 1592.823M
17.2
+25.8
-38.5
+1.7
+1.7
+0.0
7.9
14.0
-6.1
Vert
22 1553.176M
17.3
+25.6
-38.5
+1.7
+1.7
+0.0
7.8
14.0
-6.2
Vert
23 1575.426M
17.2
+25.7
-38.5
+1.7
+1.7
+0.0
7.8
14.0
-6.2
Vert
24 1591.227M
17.1
+25.8
-38.5
+1.7
+1.7
+0.0
7.8
14.0
-6.2
Vert
25 1591.531M
17.1
+25.8
-38.5
+1.7
+1.7
+0.0
7.8
14.0
-6.2
Vert
26 1596.227M
17.1
+25.8
-38.5
+1.7
+1.7
+0.0
7.8
14.0
-6.2
Vert
Page 102 of 161
Report No.: MIL05-043
27 1583.030M
17.1
+25.7
-38.5
+1.7
+1.7
+0.0
7.7
14.0
-6.3
Vert
28 1591.284M
17.0
+25.8
-38.5
+1.7
+1.7
+0.0
7.7
14.0
-6.3
Vert
29 1594.497M
17.0
+25.8
-38.5
+1.7
+1.7
+0.0
7.7
14.0
-6.3
Vert
30 1575.048M
17.0
+25.7
-38.5
+1.7
+1.7
+0.0
7.6
14.0
-6.4
Vert
Page 103 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/20/2005
10:53:46 AM
12
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 1728.640M
49.8 +26.5
-38.4
+1.8
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+1.8 +0.0
41.5
90.0
-48.5
Polar
Ant
Horiz
2 1767.129M
49.4
+26.7
-38.3
+1.8
+1.8
+0.0
41.4
90.0
-48.6
Horiz
3 1730.807M
49.6
+26.5
-38.4
+1.8
+1.8
+0.0
41.3
90.0
-48.7
Horiz
4 1681.507M
49.5
+26.3
-38.4
+1.8
+1.8
+0.0
41.0
90.0
-49.0
Horiz
5 1635.272M
49.8
+26.0
-38.4
+1.8
+1.7
+0.0
40.9
90.0
-49.1
Horiz
6 1749.613M
49.0
+26.6
-38.3
+1.8
+1.8
+0.0
40.9
90.0
-49.1
Horiz
Page 104 of 161
Report No.: MIL05-043
7 1611.830M
50.0
+25.9
-38.5
+1.7
+1.7
+0.0
40.8
90.0
-49.2
Horiz
8 1719.266M
49.2
+26.4
-38.4
+1.8
+1.8
+0.0
40.8
90.0
-49.2
Horiz
9 1727.292M
49.1
+26.5
-38.4
+1.8
+1.8
+0.0
40.8
90.0
-49.2
Horiz
10 1760.216M
48.9
+26.6
-38.3
+1.8
+1.8
+0.0
40.8
90.0
-49.2
Horiz
11 1762.677M
48.9
+26.6
-38.3
+1.8
+1.8
+0.0
40.8
90.0
-49.2
Horiz
12 1650.498M
49.5
+26.1
-38.4
+1.8
+1.7
+0.0
40.7
90.0
-49.3
Horiz
13 1682.753M
49.2
+26.3
-38.4
+1.8
+1.8
+0.0
40.7
90.0
-49.3
Horiz
14 1742.758M
48.8
+26.6
-38.3
+1.8
+1.8
+0.0
40.7
90.0
-49.3
Horiz
15 1761.095M
48.8
+26.6
-38.3
+1.8
+1.8
+0.0
40.7
90.0
-49.3
Horiz
16 1600.274M
49.9
+25.8
-38.5
+1.7
+1.7
+0.0
40.6
90.0
-49.4
Horiz
17 1627.659M
49.6
+26.0
-38.5
+1.8
+1.7
+0.0
40.6
90.0
-49.4
Horiz
18 1714.286M
49.0
+26.4
-38.4
+1.8
+1.8
+0.0
40.6
90.0
-49.4
Horiz
19 1760.685M
48.7
+26.6
-38.3
+1.8
+1.8
+0.0
40.6
90.0
-49.4
Horiz
20 1702.013M
48.9
+26.4
-38.4
+1.8
+1.8
+0.0
40.5
90.0
-49.5
Horiz
21 1672.500M
49.1
+26.2
-38.4
+1.8
+1.7
+0.0
40.4
90.0
-49.6
Horiz
22 1674.653M
49.1
+26.2
-38.4
+1.8
+1.7
+0.0
40.4
90.0
-49.6
Horiz
23 1685.359M
48.9
+26.3
-38.4
+1.8
+1.8
+0.0
40.4
90.0
-49.6
Horiz
24 1699.577M
48.9
+26.3
-38.4
+1.8
+1.8
+0.0
40.4
90.0
-49.6
Horiz
25 1659.189M
49.1
+26.1
-38.4
+1.8
+1.7
+0.0
40.3
90.0
-49.7
Horiz
26 1666.326M
49.0
+26.2
-38.4
+1.8
+1.7
+0.0
40.3
90.0
-49.7
Horiz
Page 105 of 161
Report No.: MIL05-043
27 1712.470M
48.7
+26.4
-38.4
+1.8
+1.8
+0.0
40.3
90.0
-49.7
Horiz
28 1724.597M
48.6
+26.5
-38.4
+1.8
+1.8
+0.0
40.3
90.0
-49.7
Horiz
29 1734.615M
48.5
+26.5
-38.3
+1.8
+1.8
+0.0
40.3
90.0
-49.7
Horiz
30 1739.595M
48.5
+26.5
-38.3
+1.8
+1.8
+0.0
40.3
90.0
-49.7
Horiz
Page 106 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/20/2005
9:00:09 AM
7
A. Brar
Model #
SIU
S/N
GLAT 2508
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 1763.790M
49.4 +26.7
-38.3
+1.8
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+1.8 +0.0
41.4
90.0
-48.6
Polar
Ant
Vert
2 1767.481M
49.3
+26.7
-38.3
+1.8
+1.8
+0.0
41.3
90.0
-48.7
Vert
3 1768.008M
49.0
+26.7
-38.3
+1.8
+1.8
+0.0
41.0
90.0
-49.0
Vert
4 1762.091M
49.0
+26.6
-38.3
+1.8
+1.8
+0.0
40.9
90.0
-49.1
Vert
5 1762.384M
49.0
+26.6
-38.3
+1.8
+1.8
+0.0
40.9
90.0
-49.1
Vert
6 1763.497M
48.8
+26.7
-38.3
+1.8
+1.8
+0.0
40.8
90.0
-49.2
Vert
Page 107 of 161
Report No.: MIL05-043
7 1710.113M
49.1
+26.4
-38.4
+1.8
+1.8
+0.0
40.7
90.0
-49.3
Vert
8 1755.940M
48.8
+26.6
-38.3
+1.8
+1.8
+0.0
40.7
90.0
-49.3
Vert
9 1675.786M
49.2
+26.2
-38.4
+1.8
+1.8
+0.0
40.6
90.0
-49.4
Vert
10 1754.651M
48.7
+26.6
-38.3
+1.8
+1.8
+0.0
40.6
90.0
-49.4
Vert
11 1679.411M
49.1
+26.2
-38.4
+1.8
+1.8
+0.0
40.5
90.0
-49.5
Vert
12 1700.710M
49.0
+26.3
-38.4
+1.8
+1.8
+0.0
40.5
90.0
-49.5
Vert
13 1711.359M
48.9
+26.4
-38.4
+1.8
+1.8
+0.0
40.5
90.0
-49.5
Vert
14 1713.642M
48.9
+26.4
-38.4
+1.8
+1.8
+0.0
40.5
90.0
-49.5
Vert
15 1727.409M
48.8
+26.5
-38.4
+1.8
+1.8
+0.0
40.5
90.0
-49.5
Vert
16 1731.452M
48.8
+26.5
-38.4
+1.8
+1.8
+0.0
40.5
90.0
-49.5
Vert
17 1618.074M
49.6
+25.9
-38.5
+1.7
+1.7
+0.0
40.4
90.0
-49.6
Vert
18 1733.209M
48.6
+26.5
-38.3
+1.8
+1.8
+0.0
40.4
90.0
-49.6
Vert
19 1754.768M
48.5
+26.6
-38.3
+1.8
+1.8
+0.0
40.4
90.0
-49.6
Vert
20 1628.974M
49.2
+26.0
-38.5
+1.8
+1.7
+0.0
40.2
90.0
-49.8
Vert
21 1707.904M
48.6
+26.4
-38.4
+1.8
+1.8
+0.0
40.2
90.0
-49.8
Vert
22 1634.012M
49.0
+26.0
-38.5
+1.8
+1.7
+0.0
40.0
90.0
-50.0
Vert
23 1650.882M
48.8
+26.1
-38.4
+1.8
+1.7
+0.0
40.0
90.0
-50.0
Vert
24 1701.446M
48.4
+26.4
-38.4
+1.8
+1.8
+0.0
40.0
90.0
-50.0
Vert
25 1702.409M
48.4
+26.4
-38.4
+1.8
+1.8
+0.0
40.0
90.0
-50.0
Vert
26 1640.201M
48.8
+26.0
-38.4
+1.8
+1.7
+0.0
39.9
90.0
-50.1
Vert
27 1645.624M
48.7
+26.1
-38.4
+1.8
+1.7
+0.0
39.9
90.0
-50.1
Vert
Page 108 of 161
Report No.: MIL05-043
28 1705.185M
48.3
+26.4
-38.4
+1.8
+1.8
+0.0
39.9
90.0
-50.1
Vert
29 1633.410M
48.8
+26.0
-38.5
+1.8
+1.7
+0.0
39.8
90.0
-50.2
Vert
30 1648.034M
48.6
+26.1
-38.4
+1.8
+1.7
+0.0
39.8
90.0
-50.2
Vert
Page 109 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/20/2005
11:39:34 AM
14
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 2196.486M
29.8 +27.9
-38.0
+2.0
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+2.0 +0.0
23.7
25.0
-1.3
Polar
Ant
Horiz
2 2100.000M
28.0
+27.8
-38.0
+2.0
+1.9
+0.0
21.7
25.0
-3.3
Horiz
3 1803.503M
29.1
+26.8
-38.3
+1.8
+1.8
+0.0
21.2
25.0
-3.8
Horiz
4 2259.329M
26.8
+27.9
-37.9
+2.1
+2.0
+0.0
20.9
25.0
-4.1
Horiz
5 2077.107M
27.1
+27.8
-38.0
+2.0
+1.9
+0.0
20.8
25.0
-4.2
Horiz
6 2103.934M
27.0
+27.8
-38.0
+2.0
+1.9
+0.0
20.7
25.0
-4.3
Horiz
Page 110 of 161
Report No.: MIL05-043
7 1929.469M
27.6
+27.4
-38.2
+1.9
+1.9
+0.0
20.6
25.0
-4.4
Horiz
8 2118.478M
26.9
+27.8
-38.0
+2.0
+1.9
+0.0
20.6
25.0
-4.4
Horiz
9 1974.144M
27.2
+27.6
-38.1
+1.9
+1.9
+0.0
20.5
25.0
-4.5
Horiz
10 2237.487M
26.5
+27.9
-37.9
+2.0
+2.0
+0.0
20.5
25.0
-4.5
Horiz
11 2291.705M
26.4
+27.9
-37.9
+2.1
+2.0
+0.0
20.5
25.0
-4.5
Horiz
12 2037.487M
27.0
+27.7
-38.1
+1.9
+1.9
+0.0
20.4
25.0
-4.6
Horiz
13 2038.749M
27.0
+27.7
-38.1
+1.9
+1.9
+0.0
20.4
25.0
-4.6
Horiz
14 2078.909M
26.7
+27.8
-38.0
+2.0
+1.9
+0.0
20.4
25.0
-4.6
Horiz
15 2219.939M
26.5
+27.9
-38.0
+2.0
+2.0
+0.0
20.4
25.0
-4.6
Horiz
16 1925.355M
27.3
+27.4
-38.2
+1.9
+1.9
+0.0
20.3
25.0
-4.7
Horiz
17 2085.305M
26.6
+27.8
-38.0
+2.0
+1.9
+0.0
20.3
25.0
-4.7
Horiz
18 2118.538M
26.6
+27.8
-38.0
+2.0
+1.9
+0.0
20.3
25.0
-4.7
Horiz
19 2127.697M
26.6
+27.8
-38.0
+2.0
+1.9
+0.0
20.3
25.0
-4.7
Horiz
20 2181.511M
26.4
+27.9
-38.0
+2.0
+2.0
+0.0
20.3
25.0
-4.7
Horiz
21 2230.640M
26.4
+27.9
-38.0
+2.0
+2.0
+0.0
20.3
25.0
-4.7
Horiz
22 2256.476M
26.2
+27.9
-37.9
+2.1
+2.0
+0.0
20.3
25.0
-4.7
Horiz
23 2292.938M
26.2
+27.9
-37.9
+2.1
+2.0
+0.0
20.3
25.0
-4.7
Horiz
24 1873.083M
27.5
+27.2
-38.2
+1.9
+1.8
+0.0
20.2
25.0
-4.8
Horiz
25 2033.764M
26.8
+27.7
-38.1
+1.9
+1.9
+0.0
20.2
25.0
-4.8
Horiz
26 2091.031M
26.5
+27.8
-38.0
+2.0
+1.9
+0.0
20.2
25.0
-4.8
Horiz
27 2152.512M
26.4
+27.8
-38.0
+2.0
+2.0
+0.0
20.2
25.0
-4.8
Horiz
Page 111 of 161
Report No.: MIL05-043
28 2224.905M
26.3
+27.9
-38.0
+2.0
+2.0
+0.0
20.2
25.0
-4.8
Horiz
29 2258.428M
26.1
+27.9
-37.9
+2.1
+2.0
+0.0
20.2
25.0
-4.8
Horiz
30 2266.306M
26.0
+27.9
-37.9
+2.1
+2.0
+0.0
20.1
25.0
-4.9
Horiz
Page 112 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/20/2005
10:46:34 AM
10
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 2196.486M
29.4 +27.9
-38.0
+2.0
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+2.0 +0.0
23.3
25.0
-1.7
Polar
Ant
Vert
2 2103.833M
29.5
+27.8
-38.0
+2.0
+1.9
+0.0
23.2
25.0
-1.8
Vert
3 1803.293M
30.8
+26.8
-38.3
+1.8
+1.8
+0.0
22.9
25.0
-2.1
Vert
4 1991.742M
28.9
+27.7
-38.1
+1.9
+1.9
+0.0
22.3
25.0
-2.7
Vert
5 1797.117M
29.9
+26.8
-38.3
+1.8
+1.8
+0.0
22.0
25.0
-3.0
Vert
6 2026.596M
27.9
+27.7
-38.1
+1.9
+1.9
+0.0
21.3
25.0
-3.7
Vert
Page 113 of 161
Report No.: MIL05-043
7 1994.975M
27.8
+27.7
-38.1
+1.9
+1.9
+0.0
21.2
25.0
-3.8
Vert
8 2098.328M
27.3
+27.8
-38.0
+2.0
+1.9
+0.0
21.0
25.0
-4.0
Vert
9 1979.709M
27.6
+27.6
-38.1
+1.9
+1.9
+0.0
20.9
25.0
-4.1
Vert
10 1996.807M
27.5
+27.7
-38.1
+1.9
+1.9
+0.0
20.9
25.0
-4.1
Vert
11 2103.653M
27.1
+27.8
-38.0
+2.0
+1.9
+0.0
20.8
25.0
-4.2
Vert
12 2193.303M
26.9
+27.9
-38.0
+2.0
+2.0
+0.0
20.8
25.0
-4.2
Vert
13 1797.147M
28.6
+26.8
-38.3
+1.8
+1.8
+0.0
20.7
25.0
-4.3
Vert
14 1946.416M
27.5
+27.5
-38.1
+1.9
+1.9
+0.0
20.7
25.0
-4.3
Vert
15 2029.079M
27.3
+27.7
-38.1
+1.9
+1.9
+0.0
20.7
25.0
-4.3
Vert
16 2078.438M
27.0
+27.8
-38.0
+2.0
+1.9
+0.0
20.7
25.0
-4.3
Vert
17 2173.163M
26.9
+27.8
-38.0
+2.0
+2.0
+0.0
20.7
25.0
-4.3
Vert
18 1822.693M
28.4
+26.9
-38.3
+1.8
+1.8
+0.0
20.6
25.0
-4.4
Vert
19 2188.958M
26.7
+27.9
-38.0
+2.0
+2.0
+0.0
20.6
25.0
-4.4
Vert
20 2212.642M
26.6
+27.9
-38.0
+2.0
+2.0
+0.0
20.5
25.0
-4.5
Vert
21 2037.287M
27.0
+27.7
-38.1
+1.9
+1.9
+0.0
20.4
25.0
-4.6
Vert
22 2075.775M
26.8
+27.8
-38.1
+2.0
+1.9
+0.0
20.4
25.0
-4.6
Vert
23 2085.035M
26.7
+27.8
-38.0
+2.0
+1.9
+0.0
20.4
25.0
-4.6
Vert
24 2088.568M
26.7
+27.8
-38.0
+2.0
+1.9
+0.0
20.4
25.0
-4.6
Vert
25 2125.405M
26.7
+27.8
-38.0
+2.0
+1.9
+0.0
20.4
25.0
-4.6
Vert
26 2129.850M
26.7
+27.8
-38.0
+2.0
+1.9
+0.0
20.4
25.0
-4.6
Vert
Page 114 of 161
Report No.: MIL05-043
27 2095.005M
26.6
+27.8
-38.0
+2.0
+1.9
+0.0
20.3
25.0
-4.7
Vert
28 2219.619M
26.4
+27.9
-38.0
+2.0
+2.0
+0.0
20.3
25.0
-4.7
Vert
29 2241.661M
26.3
+27.9
-37.9
+2.0
+2.0
+0.0
20.3
25.0
-4.7
Vert
30 2260.970M
26.2
+27.9
-37.9
+2.1
+2.0
+0.0
20.3
25.0
-4.7
Vert
Page 115 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Date:
Time:
Sequence#:
Tested By:
10/20/2005
8:28:29 AM
0
A. Brar
Equipment Under Test (* = EUT):
Function
Manufacturer
Model #
S/N
Support Devices:
Function
Model #
S/N
Manufacturer
Test Conditions / Notes:
Path Check Sweep. Signal at 1000.00MHz. 90 (spec limit) - 6dB - 45.9 (Antenna Factor) = 38.1dBuV = -68.9dBm
signal level.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 17995.080M
61.8 +45.9
-33.5
+6.4
Test Distance: None
T4
Dist
Corr
Spec
dB
Table dBµV/m dBµV/m
+5.9 +0.0
86.5
90.0
Margin
dB
-3.5
Polar
Ant
Pre-C
2 17976.380M
42.5
+45.8
-33.5
+6.4
+5.9
+0.0
67.1
90.0
-22.9
Pre-C
3 17921.280M
42.5
+45.5
-33.6
+6.4
+5.9
+0.0
66.7
90.0
-23.3
Pre-C
4 17970.480M
42.2
+45.7
-33.5
+6.4
+5.9
+0.0
66.7
90.0
-23.3
Pre-C
5 17951.780M
42.1
+45.7
-33.6
+6.4
+5.9
+0.0
66.5
90.0
-23.5
Pre-C
6 17895.700M
42.3
+45.4
-33.6
+6.4
+5.9
+0.0
66.4
90.0
-23.6
Pre-C
7 17885.860M
42.2
+45.3
-33.7
+6.4
+5.9
+0.0
66.1
90.0
-23.9
Pre-C
8 17845.510M
42.3
+45.1
-33.7
+6.4
+5.9
+0.0
66.0
90.0
-24.0
Pre-C
9 17862.240M
42.2
+45.2
-33.7
+6.4
+5.9
+0.0
66.0
90.0
-24.0
Pre-C
10 17570.980M
42.9
+43.7
-34.1
+6.3
+5.8
+0.0
64.6
90.0
-25.4
Pre-C
Page 116 of 161
Report No.: MIL05-043
11 17622.140M
42.4
+43.9
-34.0
+6.3
+5.8
+0.0
64.4
90.0
-25.6
Pre-C
12 17290.540M
44.4
+41.7
-34.3
+6.2
+5.8
+0.0
63.8
90.0
-26.2
Pre-C
13 17452.900M
42.8
+42.9
-34.2
+6.3
+5.8
+0.0
63.6
90.0
-26.4
Pre-C
14 17488.320M
42.2
+43.2
-34.2
+6.3
+5.8
+0.0
63.3
90.0
-26.7
Pre-C
15 17503.080M
42.1
+43.3
-34.2
+6.3
+5.8
+0.0
63.3
90.0
-26.7
Pre-C
16 17389.920M
42.6
+42.5
-34.2
+6.3
+5.8
+0.0
63.0
90.0
-27.0
Pre-C
17 17326.940M
43.2
+42.0
-34.3
+6.2
+5.8
+0.0
62.9
90.0
-27.1
Pre-C
18 17349.580M
43.0
+42.2
-34.3
+6.2
+5.8
+0.0
62.9
90.0
-27.1
Pre-C
19 17356.460M
42.8
+42.2
-34.3
+6.2
+5.8
+0.0
62.7
90.0
-27.3
Pre-C
20 16992.980M
43.4
+39.5
-34.4
+6.1
+5.7
+0.0
60.3
90.0
-29.7
Pre-C
21 14557.540M
43.0
+40.9
-35.8
+5.8
+5.2
+0.0
59.1
90.0
-30.9
Pre-C
22 16863.850M
42.9
+38.9
-34.5
+6.1
+5.7
+0.0
59.1
90.0
-30.9
Pre-C
23 13775.760M
44.2
+39.8
-35.8
+5.7
+5.1
+0.0
59.0
90.0
-31.0
Pre-C
24 14458.450M
42.8
+41.0
-35.8
+5.8
+5.2
+0.0
59.0
90.0
-31.0
Pre-C
25 16890.880M
42.7
+39.0
-34.5
+6.1
+5.7
+0.0
59.0
90.0
-31.0
Pre-C
26 14420.410M
42.8
+40.9
-35.8
+5.8
+5.2
+0.0
58.9
90.0
-31.1
Pre-C
27 14509.500M
42.5
+41.1
-35.8
+5.8
+5.2
+0.0
58.8
90.0
-31.2
Pre-C
Page 117 of 161
Report No.: MIL05-043
28 14526.510M
42.6
+41.0
-35.8
+5.8
+5.2
+0.0
58.8
90.0
-31.2
Pre-C
29 14447.430M
42.5
+41.0
-35.8
+5.8
+5.2
+0.0
58.7
90.0
-31.3
Pre-C
30 16895.880M
42.3
+39.1
-34.5
+6.1
+5.7
+0.0
58.7
90.0
-31.3
Pre-C
Page 118 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
10/20/2005
10:57:03 AM
13
A. Brar
Model #
SIU
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
GLAT 2508
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 17998.630M
42.4 +45.9
-33.5
+6.4
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+5.9 +0.0
67.1
90.0
-22.9
Polar
Ant
Horiz
2 17771.890M
43.1
+44.7
-33.8
+6.4
+5.9
+0.0
66.3
90.0
-23.7
Horiz
3 17879.440M
42.2
+45.3
-33.7
+6.4
+5.9
+0.0
66.1
90.0
-23.9
Horiz
4 17846.560M
42.2
+45.1
-33.7
+6.4
+5.9
+0.0
65.9
90.0
-24.1
Horiz
5 17861.630M
41.9
+45.2
-33.7
+6.4
+5.9
+0.0
65.7
90.0
-24.3
Horiz
6 17591.740M
43.1
+43.8
-34.1
+6.3
+5.8
+0.0
64.9
90.0
-25.1
Horiz
Page 119 of 161
Report No.: MIL05-043
7 17552.010M
42.8
+43.6
-34.1
+6.3
+5.8
+0.0
64.4
90.0
-25.6
Horiz
8 17563.650M
42.5
+43.6
-34.1
+6.3
+5.8
+0.0
64.1
90.0
-25.9
Horiz
9 17608.180M
42.1
+43.9
-34.0
+6.3
+5.8
+0.0
64.1
90.0
-25.9
Horiz
10 17618.460M
42.1
+43.9
-34.0
+6.3
+5.8
+0.0
64.1
90.0
-25.9
Horiz
11 17388.290M
43.6
+42.5
-34.2
+6.3
+5.8
+0.0
64.0
90.0
-26.0
Horiz
12 17392.400M
43.0
+42.5
-34.2
+6.3
+5.8
+0.0
63.4
90.0
-26.6
Horiz
13 17425.970M
42.7
+42.7
-34.2
+6.3
+5.8
+0.0
63.3
90.0
-26.7
Horiz
14 17301.990M
42.9
+41.8
-34.3
+6.2
+5.8
+0.0
62.4
90.0
-27.6
Horiz
15 17261.950M
43.0
+41.5
-34.3
+6.2
+5.8
+0.0
62.2
90.0
-27.8
Horiz
16 14473.160M
43.4
+41.0
-35.8
+5.8
+5.2
+0.0
59.6
90.0
-30.4
Horiz
17 16880.570M
43.0
+39.0
-34.5
+6.1
+5.7
+0.0
59.3
90.0
-30.7
Horiz
18 14458.150M
42.9
+41.0
-35.8
+5.8
+5.2
+0.0
59.1
90.0
-30.9
Horiz
19 16927.610M
42.4
+39.2
-34.5
+6.1
+5.7
+0.0
58.9
90.0
-31.1
Horiz
20 14307.000M
43.0
+40.7
-35.9
+5.8
+5.2
+0.0
58.8
90.0
-31.2
Horiz
21 13992.680M
43.9
+40.1
-36.1
+5.7
+5.1
+0.0
58.7
90.0
-31.3
Horiz
22 14110.800M
43.5
+40.3
-36.0
+5.7
+5.1
+0.0
58.6
90.0
-31.4
Horiz
23 14331.020M
42.7
+40.8
-35.9
+5.8
+5.2
+0.0
58.6
90.0
-31.4
Horiz
24 14977.670M
43.6
+39.1
-35.4
+6.0
+5.3
+0.0
58.6
90.0
-31.4
Horiz
25 14177.870M
43.2
+40.5
-36.0
+5.7
+5.1
+0.0
58.5
90.0
-31.5
Horiz
26 14283.970M
42.6
+40.7
-35.9
+5.8
+5.2
+0.0
58.4
90.0
-31.6
Horiz
Page 120 of 161
Report No.: MIL05-043
27 13831.520M
43.5
+39.9
-35.9
+5.7
+5.1
+0.0
58.3
90.0
-31.7
Horiz
28 13916.610M
43.4
+40.0
-36.0
+5.7
+5.1
+0.0
58.2
90.0
-31.8
Horiz
29 14261.950M
42.5
+40.6
-35.9
+5.8
+5.2
+0.0
58.2
90.0
-31.8
Horiz
30 16752.440M
42.5
+38.5
-34.6
+6.1
+5.7
+0.0
58.2
90.0
-31.8
Horiz
Page 121 of 161
Report No.: MIL05-043
Test Location:
CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170
Customer:
Specification:
Work Order #:
Test Type:
Equipment:
Manufacturer:
Model:
S/N:
Stanford Linear Accelerator Center
RE102 10KHz-18GHz
83492
Radiated Scan
Stanford Linear Accelerator Center
Stanford Linear
SIU
GLAT 2508
Equipment Under Test (* = EUT):
Function
Stanford Linear Accelerator Center*
Support Devices:
Function
Power Supply
VME Crate
Mouse
Keyboard
Monitor
PC
Date:
Time:
Sequence#:
Tested By:
Manufacturer
Stanford Linear
Manufacturer
AEMC Instruments
Dawn
Dell by Microsoft
Dell
Dell
Dell
10/20/2005
9:02:30 AM
8
A. Brar
Model #
SIU
S/N
GLAT 2508
Model #
AX502
11-1011777-2119
X06-08477
04N454
MX-D9J367-47605-379-AYKJ
DHM
S/N
PC70344
002563
none
TH-04N454-37171-33F-E488
PC65341
JLJJ331
Test Conditions / Notes:
Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The
10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.
Power cable is grounded to the chamber wall right before it enters the chamber.
Transducer Legend:
T1=Horn Antenna AN02113 SN4660 (Fremont)
T3=CAB HF 72" ANP05317 Pasternack
T2=HP-83017A, A/N 00785
T4=Cable AN2716 40 GHz
Reading listed by margin.
Measurement Data:
#
Freq
Rdng
T1
T2
T3
MHz
dBµV
dB
dB
dB
1 17981.510M
42.6 +45.8
-33.5
+6.4
Test Distance: 1 Meter
T4
Dist
Corr
Spec
Margin
dB
Table dBµV/m dBµV/m
dB
+5.9 +0.0
67.2
90.0
-22.8
Polar
Ant
Vert
2 17986.980M
42.2
+45.8
-33.5
+6.4
+5.9
+0.0
66.8
90.0
-23.2
Vert
3 17785.600M
42.8
+44.8
-33.8
+6.4
+5.9
+0.0
66.1
90.0
-23.9
Vert
4 17753.400M
42.7
+44.6
-33.8
+6.4
+5.9
+0.0
65.8
90.0
-24.2
Vert
5 17812.310M
42.4
+44.9
-33.8
+6.4
+5.9
+0.0
65.8
90.0
-24.2
Vert
6 17727.370M
43.0
+44.5
-33.9
+6.3
+5.8
+0.0
65.7
90.0
-24.3
Vert
Page 122 of 161
Report No.: MIL05-043
7 17679.420M
43.0
+44.2
-33.9
+6.3
+5.8
+0.0
65.4
90.0
-24.6
Vert
8 17686.270M
42.7
+44.3
-33.9
+6.3
+5.8
+0.0
65.2
90.0
-24.8
Vert
9 17690.380M
42.6
+44.3
-33.9
+6.3
+5.8
+0.0
65.1
90.0
-24.9
Vert
10 17458.850M
43.7
+43.0
-34.2
+6.3
+5.8
+0.0
64.6
90.0
-25.4
Vert
11 17466.380M
43.4
+43.0
-34.2
+6.3
+5.8
+0.0
64.3
90.0
-25.7
Vert
12 17543.110M
42.4
+43.5
-34.1
+6.3
+5.8
+0.0
63.9
90.0
-26.1
Vert
13 17421.180M
43.2
+42.7
-34.2
+6.3
+5.8
+0.0
63.8
90.0
-26.2
Vert
14 17468.440M
42.8
+43.1
-34.2
+6.3
+5.8
+0.0
63.8
90.0
-26.2
Vert
15 17391.720M
43.1
+42.5
-34.2
+6.3
+5.8
+0.0
63.5
90.0
-26.5
Vert
16 17384.190M
43.1
+42.4
-34.2
+6.3
+5.8
+0.0
63.4
90.0
-26.6
Vert
17 17435.560M
42.6
+42.8
-34.2
+6.3
+5.8
+0.0
63.3
90.0
-26.7
Vert
18 17446.520M
42.4
+42.9
-34.2
+6.3
+5.8
+0.0
63.2
90.0
-26.8
Vert
19 17311.000M
42.9
+41.9
-34.3
+6.2
+5.8
+0.0
62.5
90.0
-27.5
Vert
20 17029.710M
43.6
+39.7
-34.4
+6.1
+5.7
+0.0
60.7
90.0
-29.3
Vert
21 17025.710M
43.0
+39.7
-34.4
+6.1
+5.7
+0.0
60.1
90.0
-29.9
Vert
22 14425.110M
43.7
+41.0
-35.8
+5.8
+5.2
+0.0
59.9
90.0
-30.1
Vert
23 14482.170M
43.5
+41.1
-35.8
+5.8
+5.2
+0.0
59.8
90.0
-30.2
Vert
24 14496.180M
43.4
+41.1
-35.8
+5.8
+5.2
+0.0
59.7
90.0
-30.3
Vert
25 16938.620M
43.2
+39.2
-34.5
+6.1
+5.7
+0.0
59.7
90.0
-30.3
Vert
26 17000.690M
42.8
+39.5
-34.4
+6.1
+5.7
+0.0
59.7
90.0
-30.3
Vert
Page 123 of 161
Report No.: MIL05-043
27 16944.630M
43.0
+39.3
-34.5
+6.1
+5.7
+0.0
59.6
90.0
-30.4
Vert
28 16959.640M
42.9
+39.3
-34.4
+6.1
+5.7
+0.0
59.6
90.0
-30.4
Vert
29 16948.630M
42.9
+39.3
-34.5
+6.1
+5.7
+0.0
59.5
90.0
-30.5
Vert
30 16973.660M
42.6
+39.4
-34.4
+6.1
+5.7
+0.0
59.4
90.0
-30.6
Vert
Page 124 of 161
Report No.: MIL05-043
CS06- Conducted Susceptibility, Spikes on Power Leads
Test Equipment
Equipment
Manufacturer
Solar
Transient
Pulse Generator
HP
Oscilloscope
Solar
5 Ohms Resistor
CNR = Calibration not required.
Model #
8282-1
Serial #
881811
Asset #
00366
Cal Date
CNR
Cal Due
CNR
54615B
Type 7144-5.0
US35420829
CKC#1
00697
00141
8-29-03
CNR
8-29-05
CNR
Test Procedure
Calibration: The test Engineer connected the source’s output across a 5 ohm load and connected
an oscilloscope across the load. The output level was increased until 12Vp was displayed on the
Oscilloscope and the output level was recorded. Plots were captured to show the pulse time and
amplitude.
Test: Test Engineer connected the output of the source to the 28VDC Line and 28VDC Return
within 5cm of the UUT. The Oscilloscope was also connected across the 28VDC Line and 28V
DC Return. The source was powered on with the output set to calibration level and spikes were
injected into the power line of the UUT. The test was performed for 5 minutes in positive
polarity and then for 5 minutes in negative polarity.
Page 125 of 161
Report No.: MIL05-043
CS06 Pre-Calibration
CS06 Test Setup
Page 126 of 161
Report No.: MIL05-043
CS06 Closeup
Page 127 of 161
Report No.: MIL05-043
CS06 Rep Rate of 10pps
CS06 Pulse Amplitude and Pulse Duration
Page 128 of 161
Report No.: MIL05-043
CS06 +12V Pulse onto DC Line (Parallel Injection Method)
CS06 -12V Pulse onto DC Line (Parallel Injection Method)
Page 129 of 161
Report No.: MIL05-043
CS102 - Conducted Susceptibility, Power Leads, 10kHz to 10MHz
Test Equipment
Equipment
Manufacturer
General Radio
Oscillator
Techron
Power Amplifier
HP
Oscilloscope
Solar
Coupling Transformer
Solar
RF Coupler
Bird Electronics
50 ohms Load Resistor
NTE
Resistor
Signal Generator
Marconi
AR
AMP
Current
Measurement FCC
Probe
CNR = Calibration not required.
Model #
1310-B
7570
54615B
6220-1A
7415-3
8134
.5Ohm
Serial #
4004
8059 054333
US35420828
None
925134
01453
None
Asset #
01730
02546
00697
481
00620
25632
None
2022D
150A100A
F-35
119229/016
24830
296
00687
00894A
00731
Cal Date
Cal Due
CNR
CNR
7/6/05
7/6/07
8/31/03
8/31/07
CNR
CNR
CNR
CNR
CNR
CNR
Verified before use
9/20/05
CNR
5/4/05
9/20/07
CNR
5/4/07
Test Procedure
10-150kHz Calibration: The Oscillator’s output was connected to input of the Techron DC
amplifier. The amplifier’s output was connected to the primary side of the Audio Isolation
Transformer. A .5 ohm resistor was connected across the secondary side of the Audio Isolation
Transformer. The Oscillator was set to 10kHz and the amplitude was brought up until the
spectrum analyzer showed voltage corresponding to the calibration limit. Then Test Engineer
swept though the range of 10-150kHz and recorded the necessary output levels to obtain the
power limit.
10-150kHz Test: The Audio Isolation Transformer was connected in series with the DC power
line. A 10uF capacitor was connected across 28VDC Line and 28VDC Return. The Current
measurement probe was clamped over the 28VDC Line between the UUT and the Audio
Isolation Transformer. The current measurement probe was connected to the Spectrum
Analyzer. The test Engineer set the frequency to 10kHz and increased the levels until the
required voltage or the power limit was reached and swept though the frequency range of 10150kHz.
Page 130 of 161
Report No.: MIL05-043
150kHz-10MHz Calibration: The Signal Generator’s output was connected to the input of the
amplifier. The amplifier’s output was connected to a RF coupler, which had 50 ohms load across
the output. A current measurement probe was clamped around the lead going from the output of
the RF coupler to the 50 ohms load. The Signal Generator was set to 150kHz and the amplitude
was brought up until the spectrum analyzer indicated the voltage corresponding to the calibration
limit. The test Engineer swept though the range of 10 – 150kHz and recorded the necessary
output levels to obtain the power limit.
150kHz - 10MHz Test: The RF coupler’s output was connected to 28VDC power Line, 5cm
from the UUT. The Current measurement probe was clamped over the 28VDC Line between the
UUT and the RF coupler. The current measurement probe was connected to the Spectrum
Analyzer. The test Engineer set the frequency to 150kHz increasing the levels until the required
voltage on the Spectrum Analyzer was indicated or the power limit was reached. Then the
entire frequency range of 150kHz - 10MHz was swept.
Page 131 of 161
Report No.: MIL05-043
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration #1
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration
Page 132 of 161
Report No.: MIL05-043
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration Closeup
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Cal Test Equipment
Page 133 of 161
Report No.: MIL05-043
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Test Setup
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Test Setup Closeup
Page 134 of 161
Report No.: MIL05-043
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #2
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #3
Page 135 of 161
Report No.: MIL05-043
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #4
CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Closeup
Page 136 of 161
Report No.: MIL05-043
CSCM- Conducted Susceptibility, Common Mode, 30Hz to 150MHz
Test Equipment
Equipment
Manufacturer
Techron
AMP
Solar
Coupling Transformer
Solar
RF Coupler
General Radio
Oscillator
Bird Electronics
50 ohms Load Resistor
NTE
Resistor
Signal Generator
Marconi
AR
AMP
CNR = Calibration not required.
Model #
7570 12
6220-1A
7415-3
1310-B
8134
.5Ohm
Serial #
054333
None
925134
None
01453
None
Asset #
2546
481
00620
1703
25632
None
2022D
150A100A
119229/016
18240
00687
1211
Cal Date
Cal Due
4-7-03
4-7-05
CNR
CNR
CNR
CNR
CNR
CNR
CNR
CNR
Verified before use
9/20/05
CNR
9/20/07
CNR
Test Procedure 30Hz to 150kHz
10-150kHz Calibration: The Oscillator’s output was connected to primary side of the Audio
Isolation Transformer. 0.5 ohm resistor was connected across the secondary side of the Audio
Isolation Transformer. The Oscillator was set to 30kHz and the amplitude was brought up until
the spectrum analyzer showed voltage corresponding to the calibration limit. Then Test
Engineer swept though the range of 10 - 150kHz and recorded the necessary output levels to
obtain the power limit.
10-150kHz Test: The Audio Isolation Transformer was connected in series with the DC power
line. 0.5 ohm resistor was added to the secondary of the audio isolation transformer to dampen
the impedance per David Nelson. A 10uF capacitor was connected across the 28VDC Input
Power Line and 28VDC Return Line. The current measurement probe was clamped over the
28VDC Power Line between the UUT and the Audio Isolation Transformer. The current
measurement probe was connected to the Spectrum Analyzer. The frequency was set to 10kHz
and the levels were increased until the required voltage or the power limit was reached. The
entire frequency range of 10 - 150kHz. was swept.
Page 137 of 161
Report No.: MIL05-043
Test Procedure 150kHz – 150MHz
.150kHz - 150MHz Calibration: The Signal Generator’s output was connected to the input of
an amplifier. The amplifier’s output was connected to RF coupler, which had a 50 ohm load
across its output. The Oscilloscope was connected across the 50 ohm load measuring the voltage
to obtain the 1 watt power limit. The Signal Generator was set to 150kHz and the amplitude was
brought up until the Oscilloscope indicated the voltage necessary to obtain 1 watt. The test
engineer swept though the frequency range of 150kHz - 150MHz recording the necessary output
levels to obtain the power limit.
150kHz - 150MHz Test: The RF coupler’s output was connected to 28VDC Power Line, within
5cm from the UUT. The Oscilloscope was connected from 28VDC Power Line to Ground
between the UUT and the RF coupler. The frequency was set to 150kHz and the output level
was increased until the power limit (400mVpp) was reached. The entire frequency range of
150kHz - 150MHz was swept.
Page 138 of 161
Report No.: MIL05-043
Conducted Susceptibility Common Mode .03 - 150kHz Pre-Cal
Conducted Susceptibility Common Mode, .03 - 150kHz Test Setup
Page 139 of 161
Report No.: MIL05-043
Conducted Susceptibility Common Mode, .03 - 150kHz Closeup
Conducted Susceptibility Common Mode, 15 - 150MHz Pre-Cal
Page 140 of 161
Report No.: MIL05-043
Conducted Susceptibility Common Mode, .15 - 150kHz Test Setup
Conducted Susceptibility Common Mode, .15 - 150MHz Closeup
Page 141 of 161
Report No.: MIL05-043
RS101 - Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz
Test Equipment
Function
SA - E4446A
Current Probe F-10
GR - Oscillator
Tx Magnetic Loop
Magnetic Loop Sensor
DC Amp - 7570
Asset #
02668
02142
01703
02719
02720
02546
S/N
US44300408
37
4004 - Cal Not Required
05019
05020
8059 054333
Cal Date
01/13/2005
04/23/2003
02/28/2005
08/16/2005
08/16/2005
07/06/2005
Cal Due
01/13/2007
04/23/2005
02/28/2005
08/16/2007
08/16/2007
07/06/2007
Test Procedure
A calibration of the test setup was performed per the method specified in MIL-STD-461E
Paragraph 5.18.3.4.
The function generator was connected to the amplifier and the output of the amplifier was
connected to the transmit loop. The transmit loop was placed 5cm from the front face of the
UUT. The test engineer manually increased the frequency from 30Hz to 100KHz while
maintaining the necessary current going into the Tx loop, which was kept 10dB higher than the
required current for the limit. Current was being monitored by the current probe clamped onto
one of the two leads that were going to the Tx loop. The current was being displayed on the SA.
Testing was repeated on the back, right side, left side, parallel to cable and top faces of the UUT.
The functionality of the UUT was monitored throughout the testing.
Page 142 of 161
Report No.: MIL05-043
RS101 Radiated Susceptibility, Magnetic Field Pre-Cal
RS101 Radiated Susceptibility, Magnetic Field, Pre-Cal Closeup
Page 143 of 161
Report No.: MIL05-043
RS101 Radiated Susceptibility, Magnetic Field, Test Setup
RS101 Radiated Susceptibility, Magnetic Field, Front Side
Page 144 of 161
Report No.: MIL05-043
RS101 Radiated Susceptibility, Magnetic Field, Back Side
RS101 Radiated Susceptibility, Magnetic Field, Right Side
Page 145 of 161
Report No.: MIL05-043
RS101 Radiated Susceptibility, Magnetic Field, Left Side
RS101 Radiated Susceptibility, Magnetic Field, Top Side
Page 146 of 161
Report No.: MIL05-043
RS101 Radiated Susceptibility, Magnetic Field, Cables
Page 147 of 161
Report No.: MIL05-043
RS103 - Radiated Susceptibility, Electric Field, 10kHz to 18GHz
Test Equipment
Equipment
Signal Generator
Signal Generator
Function Generator
Amplifier
Amp (1-4GHz)
Amp (4-8GHz)
Amp (8-12GHz)
Amp (12-18GHz)
Oscilloscope
Biconical Antenna
DRG Antenna
DRG Antenna
Field Monitor
Field Probe
Field Probe
Manufacturer
Marconi
HP
BK Precision
AR
Model #
2022D
8673C
4011
30W1000M7
Serial #
119229/016
2447A00198
9902-0294
18691
Asset #
00687
02547
02237
01209
Cal Date
9/20/05
8/9/04
9/2/05
CNR
Cal Due
9/20/07
8/9/06
9/2/07
CNR
Ophir
Hughes
Hughes
Hughes
HP
EMCO
A.H. Systems
EMCO
AR
AR
AR
5162F
1277H002F000
1277H03F000
8010H04F000
54615B
3104
SAS-570
3115
FM 2000
FP 2000
FP 2080
1020
177
18
157
US35420829
2683
155
9602-4660
18327
18676
24792
02691
1461
01463
0992A
00697
00732
02525
02113
00951A
01207
00870
CNR
CNR
CNR
CNR
8/31/03
4/11/05
6/10/05
3/8/05
3/16/05
11/12/03
6/25/04
CNR
CNR
CNR
CNR
8/31/07
4/11/07
6/10/07
3/8/07
3/15/07
11/12/05
6/25/06
Test Procedure
RS103 Test Levels and polarities:
30MHz to 18GHz – 1 V/M vertical and horizontal polarities.
The output of the signal generator was connected to the amplifier. The amplifier was connected
to the E/H Field antenna. The antenna was brought in and placed in front of the UUT in vertical
polarization. The field probe was placed next to the UUT 30cm above the ground plane.
RS103 Test Sweep:
The field probe was located in front of the Tx antenna, 1kHz squarewave modulation was
applied to the threat signal with a 40dB On/Off ratio and a sweep was performed. The field
strength values were recorded at each frequency in the sweep from 30MHz to 18GHz at 1V/m
The functionality of the UUT was monitored throughout the sweep.
Antenna Polarities:
For all testing , two transmit antenna polarities were used, Vertical and Horizontal. The antenna
was set to horizontal polarity and the test was performed. Then the antenna was set to vertical
polarity and the test was performed. There were 3 antennas used; 30-200MHz, 200-1000MHz,
1-18GHz.
Page 148 of 161
Report No.: MIL05-043
30 to 200MHz Testing:
The bi-conical antenna was brought in and placed 1 meter from the UUT. The sweep was
performed using a 1kHz squarewave modulation. The field probe was used to measure the field
strength. The UUT was monitored throughout the testing for any signs of degradation. The
antenna was rotated to the vertical polarization and the sweep was repeated.
200 to 1000MHz Testing:
The DRG antenna was brought in and placed 1 meter away from the UUT. The sweep was
performed using a 1kHz squarewave modulation. The field probe was used to measure the field
strength. The UUT was monitored throughout the testing for any signs of degradation. The
antenna was rotated to the vertical polarization and the sweep was repeated.
1 to 18GHz Testing:
The DRG antenna was brought in and placed 1 meter from the UUT in horizontal polarization.
The field probe was placed in front of the antenna. The sweep was performed using a 1kHz
squarewave modulation. The field probe was used to measure the field strength. The UUT was
monitored throughout the testing for any signs of degradation. The antenna was rotated to the
vertical polarization and the sweep was repeated.
Page 149 of 161
Report No.: MIL05-043
Bicon Antenna, 30 - 200MHz Vertical Polarization Test Setup
Page 150 of 161
Report No.: MIL05-043
Horn Antenna, 200 - 1000MHz Vertical Polarization Test Setup
Horn Antenna, 200 - 1000MHz Vertical Polarization Closeup
Page 151 of 161
Report No.: MIL05-043
Horn Antenna, 1 - 18GHz Horizontal Polarization Test Setup
Page 152 of 161
Report No.: MIL05-043
Page 153 of 161
Report No.: MIL05-043
Page 154 of 161
Report No.: MIL05-043
TEST LOG
Date
10/19/2005
Name
A. Brar
Time
745
800
801
815
900
905
930
945
1015
1054
1100
1110
1127
1205
1240
1335
1349
1400
1405
1430
1445
Event
Preparing lab.
Waiting for customer. Out schedule page isn’t working at
this time, contacting William Brandle.
William mentions that it should be up in 15 minutes.
Page isn’t up yet.
David Nelson from SLAC arrives with support equipment.
We will continue with setup.
UUT has not arrived yet.
Schedule page is up. Generating test log.
Test log is ready. Placing the 10uF caps in shielded box.
Feed through caps at in a shielded box.
Setup complete, unit is functioning properly. Placing foil on
back side of the chamber, where the cables are entering.
Resistance between the UUT and test table is
0.35milliohms and resistance between the test table and
chamber wall is 0.1milliohms.
Now I’m going over the test plan with David to see which
test should be performed first.
Setting up to perform RE102 pre-cal.
Christine and I are on the conference call with Steve Behm.
Fred (witness) has arrived.
Continuing with RE102 pre-cal.
Rod antenna pre-cal complete. While we are at it we will
run the path check at 200 and 1000MHz as well. I’m
borrowing the sig gen from Christine at this time and it
needs to be returned soon.
Path check completed at 10kHz, 15.005MHz, 30MHz,
200MHz, and 1000MHz. Path checks are within
tolerance. Setting up to test from .01-30MHz.
Begin testing from .01-30MHz with Rod Antenna.
RE102 .01-30MHz SEQ 1 Rod Antenna
Complete. Pass. Adding EUT and Support Equipment to the
emissions data sheet.
Begin testing from 30-200MHz.
RE102 30-200MHz SEQ 2 Vert
RE102 30-200MHz SEQ 3 Horiz
Complete. Pass.
Page 155 of 161
Report No.: MIL05-043
1450
1503
1504
1620
1643
10/20/05
A. Brar
1645
800
820
835
855
856
915
1030
1040
1148
1157
1205
Begin testing from 200-1000MHz.
RE102 200-1000MHz SEQ 4 Vert
RE102 200-1000MHz SEQ 5 Horiz
Complete. Pass.
Now setting up to perform path check at 18GHz. Due to the
notches in the limit, test equipment has to be moved inside
of the chamber.
Setup complete. Modified the limit around the notched to
perform path check at 18GHz.
Pre-cal isn’t coming in, I will change the pre-amps
tomorrow and continue with pre-cal.
Log off.
Swapping pre-amp and transducers.
Begin path check sweep is 18GHz.
Sweep complete. Path check is within tolerance. Setting up
to perform testing.
Loaded proper test equipment list into the emissions data
sheets.
Begin testing from 1-18GHz.
RE102 1-1.55GHz Seq 6 Vert
RE102 1.6-1.77GHz Seq 7 Vert
RE102 2.3-18GHz Seq 8 Vert
RE102 1.55-1.6GHz Seq 9 Vert
1.55-1.6GHz: RBW 3KHz, VBW 9.1KHz, Sweep Time
20s/sweep, 17 sweeps.
Failing seq 9. Troubleshooting at 1.583976GHz.
The emissions are coming from J7 connector. David would
like to continue with testing.
Continuing with testing.
RE102 1.77-2.3GHz Seq 10 Vert
1.77-2.3GHz: RBW 10KHz, VBW 30KHz, Sweep Time
1s/sweep, 53 sweeps.
RE102 1-1.55GHz Seq 11 Horiz
RE102 1.6-1.77GHz Seq 12 Horiz
RE102 2.3-18GHz Seq 13 Horiz
RE102 1.77-2.3GHz Seq 14 Horiz
RE102 1.55-1.6GHz Seq 15 Horiz
Unit passes in horizontal polarity in the range of 1-18GHz.
Begin engr run in vertical polarity.
RE102 1.55-1.6GHz Seq 16 Vert
Complete. Fail.
Break for Lunch.
Page 156 of 161
Report No.: MIL05-043
1300
1304
1335
1340
1410
1415
1445
1520
1525
1635
1640
10/21/05
A. Brar
1652
1655
800
815
820
830
845
953
958
1044
1015
1045
Back form lunch.
Begin scan, lowered the RBW to 1KHz from 1.55-1.6GHz.
RE102 1.55-1.6GHz Seq 17 Vert 1KHz RBW
RE102 1.55-1.6GHz Seq 18 Vert 1KHz RBW
RE102 1.55-1.6GHz Seq 19 Vert 1KHz RBW
Seq 19 passes. Moving onto RE101.
Moving and setting up outside of the chamber for RE101
pre-cal.
Setup outside of the chamber. Realized that the magnetic
loop is out of cal. Requested it from Mariposa, they will
ship it today. I will continue with some of the CE testing for
now.
Setting up for CECM.
David would like to leave CECM for last since we need to
cut into the wires. I will setup to run CE102 pre-cal.
CE102 pre-cal setup complete.
Begin pre-cals at 10KHz, 2MHz & 10MHz.
Complete, and it is within tolerance.
Begin testing to CE102.
CE102 SEQ 20 POSITIVE LEAD
CE102 SEQ 21 Return LEAD
Complete. Unit passes.
Log off.
Renaming photos. Preparing previous data for report.
Determining which test to perform next.
CECM seems to make better sense at this time.
Randy needs to be working with S. Goulet therefore I will
need to take over in chamber 3 and C. Kendall with take
over SLAC. At this time Chuck is explaining the testing to
Robert S. Goulet’s customer is running late.
Begin testing to CECM onto DC Line & Return. Capturing
each plot with different time divisions displaying the noise
to be below the spec.
Complete. Unit is well within tolerance, Pass.
Setting up to perform RE101 path check.
Begin RE101 Path Check.
The SA is showing the signal at 50KHz, but the plot or data
sheet show not signs of the signal existing. When the SA
sweeps through the last range, we clearly see the 50KHz
signal on the SA, but now on the plot or data sheet.
Submitting a support request.
Page 157 of 161
Report No.: MIL05-043
1100
1200
1230
1245
1300
1310
1320
1355
1422
1500
Begin CS102 10-150kHz pre cal into 0.5ohm
resistor.
1530
Pre-cal complete. setting up to perform CS102 testing from
10-150kHz.
Begin testing DC Line to CS102 from 10-150kHz. There is
a 0.5 ohm resistor added to the output of the coupling
transformer per David’s request.
Complete. Pass.
Begin testing DC Return to CS102 from 10-150kHz. There
is a 0.5 ohm resistor added to the output of the coupling
transformer per David’s request.
Complete. Pass.
Log off.
Setting up for CS102 .15-10MHz pre-cal.
Setup complete. Begin pre-cal.
1620
1630
1645
10/24/05
A. Brar
On the phone with Greg, trying to resolve this problem.
No luck with this SA. Noon technical meeting.
Meeting complete. Lunch.
Back from lunch.
Unable to arrange an analyzer which will perform testing
from 20Hz to 50kHz, there is one in Chamber 3 but it is
being used by S. Goulet. The one that can be swapped with
chamber 3’s has a broken knob. We will have to delay this
test for now, that was 2 hours down the drain. I let Greg
know that whenever he gets his hands on one of the PSAs,
try running these sweeps with the new software.
Randy calls and mentions that the SA was set to collect
8000 pts and he changed it to 1000, this should resolve the
problem, I will try it again.
Now it is working fine. Setting up to test from 1m test
distance, locating a fixture to hold the loop.
Begin testing to RE101. The model number on the
emissions data sheets was listed wrong so far, I corrected
it now, it will be correct from now on.
RE101 SEQ 22 BACK SIDE – CONNECTORS
RE101 SEQ 23 LEFT SIDE
RE101 SEQ 24 FRONT SIDE
RE101 SEQ 25 RIGHT SIDE
RE101 SEQ 26 TOP SIDE
Complete. Unit passes. Setting up to perform CS102 precal from 10-150kHz.
1655
1700
800
900
Page 158 of 161
Report No.: MIL05-043
920
930
1013
1029
1035
1050
1105
1130
1150
1219
1220
1245
1330
1345
1405
1410
1425
1440
1445
1500
1512
1520
1542
1626
10/25/05
A. Brar
1656
1700
815
818
846
Pre-cal complete. Setting up to perform testing.
Realized that the UUT’s cable isn’t cut long enough for us
to be able to tap into it 5cm from the UUT. David is making
it longer.
Begin testing from .15 to 10MHz to CS102.
Complete. Pass.
Setting up and discussing CSCM.
We will start of with .15 to 150MHz range.
Begin CSCM pre-cal from .15-150MHz.
Pre cal complete.
Begin testing to CSCM from .15-150MHz.
Complete. Pass.
Lunch.
Back from lunch. Continuing with CSCM pre-cal for lower
frequency range.
Pre-cal procedure seems to be wrong, I will follow the limit
specified in MIL STD 461 E. Chuck isn’t’ available at this
time to discuss the procedure.
CSCM .03-150kHz setup complete. Begin testing from .03150kHz.
Complete. Pass.
Setting up to perform CS02 pre-cal.
Begin CS02 pre-cal.
Pre-cal complete. Setting up to perform CS02 testing.
Chuck called regarding CSCM from .03-150kHz, and
mentioned that the pre cal is just to confirm that the wave is
sinusoidal at 30Hz when the amplitude is 19.9Vp-p.
Begin testing to CS02. Testing at +/-12V parallel injection
method. 5 minutes at each polarity, applying 10pps.
Complete. Pass.
Setting up to perform RS103.
Cleaned out the chamber for the low frequency antenna.
Begin testing to RS103 from 30-200MHz in Vertical. Using
1kHz 50% duty cycle PM. Dwell time is 3 seconds.
Test complete up to 200MHz. Unit passes.
Log off.
I was running late due to traffic.
Begin testing to RS103 from 30-200MHz in Horizontal.
Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds.
Complete. Pass.
Page 159 of 161
Report No.: MIL05-043
855
918
920
945
950
1025
1045
1110
1300
1345
1422
1618
1623
10/26/05
A. Brar
1650
1655
1657
1700
800
810
819
931
935
Begin testing to RS103 from 200-1000MHz in Vertical.
Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds.
Complete. Pass.
Begin testing to RS103 from 200-1000MHz in Horizontal.
Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds.
Complete. Pass.
Administrative work, catching up with equipment list and
so on.
Added test equipment list, needs to be updated as far as cal
dates. Now continuing with 1-18GHz RS103 setup.
HF Sig Gen isn’t available yet, Robert needs it for about an
hour. I requested the customer to take longer lunch and by
the time he gets back we will have the sig gen. Updating
equipment list.
Equipment list updated.
Robert mentions that he should be done by 1330 with the
HF Sig Gen.
Robert is done with the equipment. I’m moving it over to
MIL Chamber and setting it up.
Begin testing to RS103 from 1-18GHz in Horizontal. Using
1kHz 50% duty cycle PM. Dwell time is 1 seconds.
Complete. Pass.
Begin testing to RS103 from 1-4GHz in Vertical. Using
1kHz 50% duty cycle PM. Dwell time is 1 seconds.
Complete. Pass.
David is shutting down the unit.
Completing work order back with today’s changes.
Log off.
Booting up equipment.
Waiting for the UUT to be ready.
Begin testing to RS103 from 4-18GHz in Vertical. Using
1kHz 50% duty cycle PM. Dwell time is 1 seconds.
Complete. Pass. RS103 testing has been completed from
30MHz to 18GHz and the unit passes in this range at
1V/m level. The TP stated start frequency to be 14kHz,
but per David Nelson and according to previous testing
we ended up starting off at 30MHz.
Tearing down RS103 setup to start off with RS101 pre-cal.
Page 160 of 161
Report No.: MIL05-043
1030
Setup for RS101 pre-cal complete. Not calculating the
numbers.
1100
1113
1145
Begin RS101 pre-cal.
1220
1225
1432
1435
Pre-cal complete, the final result
Begin testing to RS101. Testing cables, back side, right
side, front side, left side and top side.
RS101 complete. Unit Passes.
All testing per the test procedure has been completed and
the unit has met all of the requirements per the procedure.
All data has been updated and it is ready to be uploaded.
Log off.
Page 161 of 161
Report No.: MIL05-043