Joint Dual, ID:0880wi03
Transcription
Joint Dual, ID:0880wi03
CERTIFICATE Certified Passive House Component Component-ID 0880wi03 valid until 31st December 2016 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt Germany Window frame Joint Dual, Limonest, France Product name: Fenêtre DUAL Passive Category: Manufacturer: This certificate was awarded based on the following criteria for the cool, temperate climate zone Comfort UW = 0.79 UW , installed with Ug ≤ ≤ = 0.80 W/(m2 K) 0.85 W/(m2 K) 0.70 W/(m2 K) Hygiene fRsi=0.25 ≥ 0.70 cool, temperate climate ph B Passive House efficiency class phE www.passivehouse.com phD phC phB phA C E RT I F I E D COMPONENT Passive House Institute Joint Dual Allée des Ormeaux, 69578 Limonest, France T +33 478 66 46 30 | B [email protected] | Í http://www.joint-dual.com | o 20 C o 18 C o 16 C o 14 C o 12 C o 10 C o 8 C o 6 C o 4 C o 2 C o 0 C o -2 C o -4 C o -6 C o -8 C o -10 C Calculation model Isothermal Description Timber (λ = 0.13 W/(mK)) -aluminium frame with insulation made of PET-foam (λ = 0.037 W/(mK)) and PVC-rigid foam (λ = 0.063 W/(mK)). Pane thickness: 44 mm (4/16/4/16/4), rebate depth: 16 mm. Explanation The window U-values were calculated for the test window size of 1.23 m × 1.48 m with Ug = 0.70 W/(m2 K). If a higher quality glazing is used, the window U-values will improve as follows: Glazing Window Ug = UW = 0.70 0.64 0.58 0.52 ↓ ↓ ↓ ↓ 0.79 0.75 0.71 0.67 W/(m2 K) W/(m2 K) Transparent building components are classified into efficiency classes depending on the heat losses through the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, and the glazing edge lengths are included in these heat losses. A more detailed report of the calculations performed in the context of certification is available from the manufacturer. The Passive House Institute has defined international component criteria for seven climate zones. In principle, components which have been certified for climate zones with higher requirements may also be used in climates with less stringent requirements. In a particular climate zone it may make sense to use a component of a higher thermal quality which has been certified for a climate zone with more stringent requirements. Further information relating to certification can be found on www.passivehouse.com and passipedia.org. 2/4 www.passivehouse.com Fenêtre DUAL Passive Frame width U -value frame Ψ -glass edge Temp. Factor bf Uf Ψg fRsi=0.25 Frame values 2 mm W/(m K) W/(m K) [-] Top (to) 118 0.75 0.027 0.72 Side (s) 118 0.75 0.027 0.71 Bottom (bo) 138 0.85 0.026 0.71 Mullion (fm) 145 0.86 0.027 0.71 (m1) 201 0.84 0.027 0.71 flying Mullion 1 casement Spacer: SWISSPACER Ultimate Component-ID: 0880wi03 Secondary seal: Polysulfide 3/4 www.passivehouse.com Validated installations Cavity wall Insulated formwork blocks Timber frame UWall = 0.13 W/(m2 K) UWall = 0.15 W/(m2 K) UWall = 0.13 W/(m2 K) Ψinstall W/(m K) W/(m K) Ψinstall Ψinstall W/(m K) Top 0.009 Top 0.005 Top 0.017 Side 0.009 Side 0.005 Side 0.017 Bottom 0.037 Bottom 0.027 Bottom 0.029 2 UW ,installed = 0.84 W/(m K) 2 UW ,installed = 0.82 W/(m K) EIFS UWall = 0.13 W/(m2 K) Ψinstall W/(m K) Top 0.007 Side 0.007 Bottom 0.029 UW ,installed = 0.83 W/(m2 K) www.passivehouse.com UW ,installed = 0.85 W/(m2 K)