shock arrestor schedule plumbing general notes plumbing fixture
Transcription
shock arrestor schedule plumbing general notes plumbing fixture
PLUMBING GENERAL NOTES I. GENERAL REQUIREMENTS: 1. 2. 3. 4. 5. PLUMBING CONTRACTOR IS TO FURNISH AND PAY FOR ALL LABOR, MATERIAL, EQUIPMENT, PERMITS & FEES REQUIRED FOR THE COMPLETE INSTALLATION OF ALL SYSTEMS IN THIS SECTION OF WORK. 1. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH NC PLUMBING CODE AND ALL OTHER APPLICABLE CODES. PC IS TO COORDINATE W/ G.C. IN REGARDS TO PROJECT TIMELINE, WORK HOURS, AS WELL AS ANY BONDING OR INSURANCE REQUIREMENTS. 2. ALL PLUMBING FIXTURES AND PLUMBING SYSTEM EQUIPMENT SHALL BE PROVIDED COMPLETE WITH ALL ACCESSORIES, HANGERS, VALVES, STOPS, TAILPIECES, TRAPS, FAUCETS, STRAINERS, ETC REGARDLESS OF PRESENCE ON PLANS. SEE FIXTURE SCHEDULE. 3. ALL EQUIPMENT, MATERIALS AND INSTALLATION SHALL BE GUARANTEED TO BE FREE OF DEFECTS FOR A PERIOD OF ONE (1) YEAR AFTER FINAL ACCEPTANCE OF WORK OR IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD GUARANTEE, IF LONGER. EXISTING EQUIPMENT IS EXCLUDED FROM WARRANTY REQUIREMENT. THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL LOCATION AND ARRANGEMENT OF ALL MATERIALS AND EQUIPMENT. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS BUILDING CONSTRUCTION AND ALL OTHER WORK WILL PERMIT. 6. DO NO SCALE DRAWINGS FOR MEASUREMENT. 7. INFORMATION GIVEN IN SCHEDULES INCLUDES BOTH DESCRIPTION OF PRODUCT AND MANUFACTURER'S MODEL #. IF CONFLICT IS PRESENT BETWEEN DESCRIPTION AND MODEL #, EQUIPMENT DESCRIPTION SHALL TAKE PRECEDENT. IN CASE OF CONFLICT BETWEEN THE PLANS AND NOTES/SPECIFICATIONS OR CONFLICT BETWEEN INFORMATION PRESENTED ON THE PLANS OR IN THE NOTES/SPECIFICATIONS, THEN THE MOST RESTRICTIVE SHALL TAKE PRECEDENT. 8. 9. 10. 11. IV. COORDINATION: BEFORE BID PC IS RESPONSIBLE FOR CLARIFYING W/ G.C. ANY CONFUSION IN REGARDS TO RESPONSIBILITY OF WORK TO BE PERFORMED OR MATERIALS TO BE PROVIDED. THE SUBMITTAL OF THE BID BY THE CONTRACTOR WILL BE HELD AS PROOF THAT THE CONTRACTOR UNDERSTANDS THOROUGHLY AND COMPLETELY THE SCOPE OF THE WORK INVOLVED, AND HAS INCLUDED ON THE BID ALL THE NECESSARY ITEMS TO CARRY OUT THIS SECTION OF WORK. ALL EXISTING EQUIPMENT AND SYSTEMS ARE ASSUMED BY ENGINEER TO BE IN GOOD WORKING ORDER. BEFORE BEGINNING WORK P.C. IS TO ENSURE ANY EQUIPMENT & SYSTEMS TO REMAIN ARE PROPERLY FUNCTIONING. NOTIFY G.C. IMMEDIATELY IF PROBLEMS ARE DISCOVERED. ALL QUESTIONS MUST BE SUBMITTED IN RFI FORMAT TO THE ARCHITECT AND MUST BE ADDRESSED BY THE APPROPRIATE DESIGNER OF RECORD PROIR TO BECOMING A PROPOSED CHANGE ORDER. P.C. IS TO REVIEW COMPLETE DRAWING SET. P.C. IS RESPONSIBLE FOR WORK EXPLICITLY SHOWN AND WORK IMPLIED. UNLESS OTHERWISE NOTED FINAL PLUMBING CONNECTION TO ALL EQUIPMENT, FIXTURES, ETC IS THE RESPONSIBILITY OF THE P.C.. 2. 3. 4. 5. 6. ALL ROOF PENETRATIONS, FLASHING, ETC ARE TO BE PERFORMED BY ROOFING CONTRACTOR. ALL LOW VOLTAGE WIRING RELATED TO PLUMBING EQUIPMENT AND SYSTEMS IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR. ALL HIGH VOLTAGE CONNECTIONS TO PLUMBING EQUIPMENT, INCLUDING DISCONNECTS TO BE PROVIDED AND INSTALLED BY E.C. G.C. TO BE RESPONSIBLE FOR PROVIDING AND INSTALLING ANY ACCESS DOORS RELATED TO PLUMBING SYSTEM (W/ EXCEPTION OF CLEANOUT COVERS, BY P.C.). P.C. RESPONSIBLE FOR COMMUNICATING TO G.C. SIZE AND LOCATION OF REQ'D ACCESS DOOR(S). ALL GAS PIPING IS BY PLUMBING CONTRACTOR. 8. WATER HEATER VENT BY MECHANICAL CONTRACTOR. III. MATERIALS: 1. ALL MATERIALS SHALL BE NEW UNLESS OTHERWISE SHOWN OR SPECIFIED. 2. ALL MATERIALS INSTALLED IN RETURN PLENUM ARE TO BE PLENUM RATED. 3. 4. PIPING MATERIALS AND FITTINGS SHALL BE AS FOLLOWS: WASTE & VENT (ABOVE & BELOW SLAB): PVC PIPE, PVC SOCKET FITTINGS, AND SOLVENT-CEMENTED FITTINGS. DOMESTIC WATER (BELOW SLAB): TYPE 'K' COPPER. DOMESTIC WATER (ABOVE SLAB): TYPE 'L' COPPER WITH SWEATED SOCKET FITTINGS. THREADED FITTINGS MAY BE USED AT VALVES, FIXTURES & SIMILAR. OR CPVC PIPING WITH SOLVENT-CEMENTED FITTINGS. THREADED FITTINGS MAY BE USED AT VALVES, FIXTURES & SIMILAR OR PEX PIPING WITH FLARED OR MECHANICAL JOINTS/FITTINGS. GAS PIPING (ABOVE SLAB): SCHEDULE 40 BLACK STEEL PIPE W/ THREADED FITTINGS. APPROVED FLEXIBLE GAS PIPING MAY BE USED AT CONNECTION TO EQUIPMENT. INSULATION IS REQUIRED ON THE FIRST 8 FEET OF HOT WATER PIPING FROM WATER HEATERS ON NON-CIRCULATING SYSTEMS. INSULATION IS REQUIRED ON ALL HOT WATER PIPING THAT IS PART OF A HOT WATER CIRCULATION LOOP & THE FIRST 8 FEET OF BRANCH LINES FROM CIRCULATION LOOP. INSULATION TO BE EQUAL TO "ARMAFLEX" PIPE INSULATION W/ SEALED OR TAPED SEAMS. INSULATION TO BE MIN. 12" THICK FOR NON CIRCULATING SYSTEMS AND MIN. 1" THICK FOR CIRCULATING SYSTEMS. INSULATION TO HAVE A CONDUCTIVITY NOT EXCEEDING WHICHEVER IS MORE STRINGENT. 5. 6. PROVIDE HANGERS & SUPPORTS APPROVED FOR USE BY 2012 NC PLUMBING CODE. ANY PLUMBING FIXTURES WITH A COMMON SHUT-OFF VALVE (I.E. PRE-RINSE, KITCHEN SINK, MOP SINK) ARE TO INCLUDE A CHECK VALVE ON THE HOT & COLD WATER VALVES TO PREVENT INTERCONNECTION OF HOT & COLD WATER LINES. MANUFACTURER MODEL NO. MATERIAL STYLE MANUFACT. MODEL NO. SPOUT DRAIN HANDLES CENTERS TYPE SIZE - P-1 WATER CLOSET FLUSH TANK AMERICAN STANDARD 2835.128 VITREOUS CHINA ADA ELONGATED - - - - - P-2 LAVATORY WALL MOUNT AMERICAN STANDARD 0355.012 VITREOUS CHINA ADA D-SHAPE AMER. STD. 6055.202 (W/ MIX VALVE) CENTER AUTO 4" 3-HOLE P-3 MOP SINK FLOOR MOUNT FIAT MSB-3624 MOLDED STONE ONE-PIECE 36x24 CENTER 2 (W/ CHECK VALVES) FIAT 830-AA SUPPLIES AND STOPS PIPE SIZES MOUNTING WASTE VENT CW WATTS Q894AC12 FLOOR GRID WATTS Q894AB20 WALL 8" 2-HOLE DOME - FLOOR ZURN FD-2211-ST PVC ADJUSTABLE - - - - - - - SEE PLAN FLOOR FS FLOOR SINK 6" DEEP ZURN FD-2375 CAST-IRON, PORCELAIN ENAMEL ANTI-SPLASH - - - - - - - SEE PLAN FLOOR HB HOSE BIB ANGLE ZURN Z1341-BFP BRONZE - - - - - - - - HD HUB DRAIN FUNNEL ZURN Z326 CAST-IRON THREADED - - - - - - - RP-1 RECIRC. PUMP MAGNETIC DRIVE WILO STAR-Z ECO BRASS MAINT. FREE - - - - - - - TD-1 TRENCH DRAIN FLOOR MOUNT ADVANCE TABCO FRG-24 STAINLESS STEEL FLOOR TROUGH DRAIN - - - - GRATE 3" - P.C. RESPONSIBLE FOR EXECUTING ALL CODE REQUIRED TESTS AND INSPECTIONS, INCLUDING BUT NOT LIMITED TO, LEAK & PRESSURE TESTING OF GAS, WASTE, VENT & WATER PIPING AND SANITIZING OF WATER PIPING. WCO WALL CLEANOUT TEE CHARLOTTE PIPE PVC-445 PVC FLUSH PLUG - - - - - - - 3. ENSURE PIPING LOCATED ON EXTERIOR WALLS (OR OTHER WALLS EXPOSED TO FREEZING CONDITIONS) IS INSTALLED ON WARM-SIDE OF WALL INSULATION. WH-1 WATER HEATER DIR. VENT GAS STATE WATER HEATERS SBD100 199NE GLASS LINED UPRIGHT - - - - - - - 4. ANY NOTCHING, DRILLING, BORING OR OTHER ALTERATION TO BUILDING STRUCTURE SHALL BE PERFORMED IN A CODE APPROVED METHOD AND NOT THREATEN THE INTEGRITY OF THE BUILDING STRUCTURE. 5. SUPPORT ALL PIPING IN ACCORDANCE W/ 2012 NC PLUMBING CODE. ANY SUSPENDED MATERIALS SHALL BE DIRECTLY SUPPORTED BY THE BUILDING STRUCTURE. 6. PENETRATIONS OF ALL EXTERIOR WALLS, FLOORS AND CEILINGS SHALL BE SEALED IN AN AIR TIGHT MANNER AND IN ACCORDANCE W/ 2012 NCECC APPENDIX 2 DETAILS. 5. 6. THE PLUMBING CONTRACTOR SHALL COORDINATE CLOSELY WITH ALL OTHER TRADES TO AVOID CONFLICT AND ENSURE OTHER TRADES PROVIDE MEASURES TO ACCOMMODATE PLUMBING WORK (I.E. ACCESS DOORS, SLAB/WALL/ROOF OPENINGS, ELECTRICAL CONNECTIONS, ETC) PIPING SHOULD BE COORDINATED WITH ALL STRUCTURAL FOOTINGS AND FOUNDATIONS. PIPE SHOULD BE OFFSET TO AVOID CONTACT WITH FOOTINGS AND FOUNDATION WALLS. IF PIPING MUST RUN UNDERNEATH A FOOTING OR THROUGH A FOUNDATION WALL, THE PIPE MUST BE INSTALLED WITH A RELIEVING ARCH OR IN A PIPE SLEEVE. P.C. TO REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS OF PLUMBING FIXTURES. V. EXECUTION: 1. 2. 7. 8. 9. 10. 11. 12. 13. 14. P.C. TO FOLLOW MANUFACTURER'S INSTRUCTIONS WHEN INSTALLING PLUMBING EQUIPMENT. ENSURE REQUIRED MAINTENANCE ACCESS AND CLEARANCES ARE MAINTAINED. IF CONFLICT EXISTS BETWEEN THESE PLANS AND MFG INSTRUCTIONS CONTACT ENGINEER. CLEANOUT PLUGS SHALL BE INSTALLED IN ACCORDANCE WITH PLUMBING CODE REQUIREMENTS. PROVIDE CLEANOUTS AS PLANS INDICATED AND AT THE BASE OF ALL WASTE STACKS, AT EVERY FOUR 45 DEGREE TURNS, AT EVERY 100 FEET, AND AT THE BASE OF ALL ROOF LEADERS. CLEANOUTS SHALL BE PLACED IN READILY ACCESSIBLE LOCATIONS. SUPPLY BRANCH LINES SERVING MORE THAN (1) FIXTURE SHALL INCLUDE SHUT-OFF VALVE. LABEL VALVE AND LOCATE AS CLOSE TO RISER/MAIN AS POSSIBLE. (NCPC 606.2.1) VALVES NOT DIRECTLY AT EQUIPMENT SHALL BE LABELED INDICATING THE FIXTURE OR AREA SERVED. (NCPC 606.4) WATER HEATER SHALL BE FILLED WITH WATER AND PURGED AS SOON AS INSTALLED OR IN NO EVENT LATER THAN GAS/ELECTRIC HOOK-UP. COPPER PIPING SHALL BE PROTECTED AGAINST CONTACT WITH MASONRY OR DISSIMILAR METALS. ALL HANGERS, SUPPORTS, ANCHORS, AND CLIPS SHALL BE COPPER OR COPPER PLATED. WHERE COPPER PIPING IS CARRIED ON IRON TRAPEZE HANGERS WITH OTHER PIPING, SATISFACTORY AND PERMANENT ELECTROLYTIC ISOLATION MATERIAL SHALL PROTECT THE COPPER AGAINST CONTACT WITH OTHER METALS. WHERE COPPER PIPING IS SLEEVED THROUGH MASONRY, SLEEVES SHALL BE COPPER OR RED BRASS. WHERE COPPER MUST BE CONCEALED IN A MASONRY PARTITION OR AGAINST MASONRY, CONTACT SHALL BE PREVENTED BY COATING THE COPPER HEAVILY WITH ASPHALTIC ENAMEL AND PROVIDING 15# ASPHALT SATURATED FELT BETWEEN THE PIPE AND MASONRY. ALL PIPE INSULATION SHALL RUN CONTINUOUSLY THROUGH FLOORS, WALLS, AND PARTITIONS. PIPE INSULATION SHALL BE MITERED AT ELBOWS AND TEES TO ENSURE COMPLETE COVERAGE OF PIPING. PROVIDE SHUT OFF VALVES ON THE FIXTURE SUPPLY TO EACH PLUMBING FIXTURE, APPLIANCE, OR MECHANICAL EQUIPMENT. 15. VACUUM BREAKERS SHALL BE PROVIDED FOR ALL FIXTURES TO WHICH HOSES MAY BE ATTACHED. VACUUM BREAKERS SHALL BE PERMANENTLY ATTACHED. 16. THE PLUMBING CONTRACTOR SHALL PROVIDE WATER HAMMER PROTECTION ON ALL WATER DISTRIBUTION PIPING SERVING EQUIPMENT W/ QUICK CLOSING VALVES (ICE MAKERS, DISHWASHERS, FLUSH VALVES, WASHING MACHINES, WATER COOLERS, ETC.) SEE SHOCK ARRESTOR SCHEDULE. 17. ACCESS DOORS TO BE PROVIDED FOR ALL VALVES AND DEVICES REQUIRING ACCESS WHEN LOCATED IN WALLS OR ABOVE INACCESSIBLE CEILING CONSTRUCTION. ACCESS DOORS TO BE RATED WHERE INSTALLED IN RATED ASSEMBLIES. 18. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL PLUMBING EQUIPMENT FROM FOREIGN MATERIAL DURING CONSTRUCTION (PAINT, SPACKLE, ETC.). UPON COMPLETION OF WORK THE PLUMBING CONTRACTOR SHALL CLEAN, WASH, ETC ALL ITEMS AND EQUIPMENT WITHIN HIS SCOPE OF WORK AND LEAVE ALL ITEMS BRIGHT AND CLEAN. 19. PROVIDE PRESSURE REDUCING VALVE IF INCOMING WATER PRESSURE EXCEEDS 80 PSI. 20. NO INSULATION PERMITTED ON BACKFLOW PREVENTOR ASSEMBLY. 21. GAS FIRED COOKING EQUIPMENT TO BE INSTALLED IN ACCORDANCE W/ NCFGC SEC 411.1.1. INSTALLATION TO INCLUDE FULL-SIZE SHUT OFF VALVE, COMMERCIAL GRADE ANSI RATED FLEXIBLE CONNECTION EQUAL TO EQUIPMENT CONNECTION SIZE W/ SWIVEL (6' MAX) AND RESTRAINING CABLE(S). SHOCK ARRESTOR SCHEDULE MFG & MODEL (OR EQUAL) IND. FIXTURE SEE FIXTURE SCHEDULE SIOUX CHIEF "MINI-RESTER" 1-11 A (1/2") SIOUX CHIEF "HYDRA-RESTER" 12 - 32 B (3/4") SIOUX CHIEF "HYDRA-RESTER" 33-60 C (1") SIOUX CHIEF "HYDRA-RESTER" 61-113 D (1") SIOUX CHIEF "HYDRA-RESTER" 114-154 E (1") DOMESTIC HOT WATER PIPING HWR WASTE (SANITARY SEWER) GW WASTE (GREASE) G GAS PIPING SIOUX CHIEF "HYDRA-RESTER" BV-1 FULL-PORT BALL VALVE MFG & MODEL (OR EQUAL) CV-1 DBL CHECK VALVE CV-2 BRONZE CHECK VALVE WATTS CV PRV-1 PRESS. RED. VALVE WATTS 223-S (SET TO 40 PSI) TV-1 IND. TEMP. VALVE LEONARD 270-LF TV-2 MASTER TEMP. VALVE N170-M3 CSUT GBV-1 GAS BALL VALVE APOLLO 80 SERIES GSV-1 GAS SOLENOID VALVE BY OTHERS W/ DOME STRAINER. W/ DEEP SEAL TRAP. W/ HALF GRATE W/ VACUUM BREAKER. WALL W/ DEEP SEAL TRAP. SEE PLAN FLOOR MAX 1.2 GPM @ 3FT TDH. IN-LINE W/ TYPE 304 S.S. GRATE FLOOR SEE PLAN WALL W/ ZURN CO-2530 WALL COVER. W/ PVC PLUG W/ THREADED TAP. 100 GALLON, 199 MBH INPUT. PLATFORM AIR ADMITTANCE VALVE ABV ABOVE AHJ AUTHORITY HAVING JURISDICTION AFF ABOVE FINISHED FLOOR BFP BACK FLOW PREVENTER BV BALL OR BALANCING VALVE (SEE SCHED) CV CHECK VALVE CW COLD WATER DN DOWN E.C. ELECTRICAL SUB-CONTRACTOR FCO FLOOR CLEAN OUT FLOOR DRAIN FROM DEMO PIPING/EQUIPMENT FS FLOOR SINK VALVE GBV G.C. GAS BALL VALVE GENERAL CONTRACTOR VALVE GSV HB GAS SOLENOID VALVE HOSE BIBB HD HUB DRAIN HW HOT WATER PIPE UP M.C. MECHANICAL SUB-CONTRACTOR PIPE DOWN P.C. PLUMBING SUB-CONTRACTOR PRV PRESSURE REDUCING VALVE SS SANITARY SEWER TV TEMPERING VALVE V VENT W WASTE WF WALL FAUCET WH WATER HEATER WHD WALL HYDRANT CLEANOUT CONNECT TO EXISTING POINT DEMO TO POINT ### AAV FR FLOOR SINK BELL & GOSSETT CB (CIRCUIT SETTER PLUS, W/ TEST PORTS) WATTS SD-2-MF (<1/2"), WATTS 9D (1/2"+) (ASSE 1022 APPROVED) BALANCING VALVE W/ NICKEL GRATE. W/ DEEP SEAL TRAP. FD FLOOR DRAIN WATTS LFB6081 BV-2 W/ WALL BRACKET. W/ MOP HANG. W/ HOSE & HOSE BRACKET. W/ VACUUM BREAKER. EXISTING PIPING/EQUIPMENT CHECK VALVE VALVE SCHEDULE DESCRIPTION DOMESTIC HOT WATER RETURN VENT PIPING NOTES: 1. LOCATED SHOCK ARRESTORS IN ACCESSIBLE LOCATION OR PROVIDE SIOUX CHIEF BRAND ARRESTORS ONLY. 2. SEE PLAN, RISERS, SCHEDULES FOR ARRESTER LOCATIONS. IF LOCATION NOT INDICATED INSTALL IN ACCORDNCE W/ MFG GUIDELINES. TAG W/ WALL BRACKET. 0.25 GPM. MOUNT AT ADA HEIGHT. DC PWR. PLUMBING LEGEND DOMESTIC COLD WATER PIPING UNIT SIZE (CONN. SIZE) PROVIDE OPEN FRONT SEAT WITH NO LID. W/ TIMER. NOTES: 1. ALL FIXTURE COLORS & FINISHES TO BE APPROVED BY OWNER & ARCHITECT BEFORE PURCHASING. 2. PROVIDE P-TRAP AND SUPPLY LINE SAFETY COVERS FOR ALL ADA SINK AND LAVATORY INSTALLATIONS. 3. WATER CLOSET HANDLES TO BE LOCATED ON "WIDE SIDE" OF STALL FOR ADA FIXTURES. 4. SEE DETAIL SHEET FOR ADDITIONAL ITEMS TO BE PROVIDED/INSTALLED W/ FIXTURES LISTED ABOVE. FIXTURE UNITS REMARKS HW FINISHED FLOOR G.C. TO BE RESPONSIBLE FOR PROVIDING AND INSTALLING ANY WATER HEATER PLATFORMS, EITHER FLOOR/WALL MOUNTED OR SUSPENDED. P.C. TO COMMUNICATE REQ'S TO G.C. 7. P.C. TO COORDINATE W/ G.C. AND ARCH PLANS TO ENSURE NECESSARY BACKING/SUPPORTS ARE INSTALLED TO ALLOW INSTALLATION OF PLUMBING FIXTURES. TYPE FLOOR DRAIN PLUMBING CONTRACTOR IS TO EMPLOY THE SERVICES OF THE G.C. FOR CUTTING AND PATCHING OF WALLS, FLOORS & CEILINGS RELATED TO THE INSTALLATION OF PLUMBING EQUIPMENT & SYSTEMS. G.C. RESPONSIBLE FOR PAINTING OF GAS PIPING ON EXTERIOR OF BUILDING. P.C. RESPONSIBLE FOR CLEANING AND PREPARING PIPING FOR PAINT, COORDINATE W/ G.C. P.C. TO COORDINATE LOCATION OF ALL ROOF PENETRATIONS W/ ROOFING CONTRACTOR & MECHANICAL CONTRACTOR. P.C. & M.C. TO COORDINATE TO ENSURE NO PLUMBING VENTS ARE LOCATED WITHIN 10' OF ANY OUTSIDE AIR INTAKES. FAUCET/VALVE FIXTURE MARK FD 4. II. DIVISION OF WORK: 1. BEFORE BEGINNING WORK INVERT ELEVATIONS SHALL BE ESTABLISHED. PC IS TO ENSURE PROPER SLOPES OF ALL WASTE AND STORM PIPING CAN BE MAINTAINED, CONTACT ENGINEER IMMEDIATELY IF PROBLEM/ISSUE IS DISCOVERED. PLUMBING FIXTURE SPECIFICATIONS AND CONNECTION SCHEDULE 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical KITCHEN EQUIPMENT TAG NOTES: 1. SEE PLAN FOR SIZE. VALVE SIZE TO EQUAL LINE SIZE. 2. BALL VALVES TO INCLUDE REMOVABLE HANDLES. 3. IF AVAILABLE, VALVES MAY BE THREADED OR SWEATED CONNECTIONS. USE EXTREME CARE AND LOW TEMP SOLDER TO PROTECT VALVE SEATS IF SWEATED CONNECTIONS ARE USED. 4. VERIFY SOLENOID VALVE DETAILS W/ E.C. & KITCHEN EQUIPMENT/HOOD MFG. Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 P-1 PLUMBING SCHEDULES & NOTES FIRE RATING LEGEND 1-HR WALL CV CW MAKE-UP TIME CLOCK TC BV G CV GAS FROM GAS MAIN RP-1 H.W. RETURN UN UN HW TO FIXTURES THER. SHUT-OFF VALVE (TYP) ITEM # QTY. DESCRIPTION DIRECT DRAIN SIZE (IN) EXPANSION TANK INDIR. DRAIN SIZE (IN) VACUUM BREAKER COLD WATER SIZE (IN.) TYPE 'B' FLUE THRU ROOF BY MC. HOT WATER SIZE (IN.) EQUIPMENT SCHEDULE 10 3 HAND SINK 0.5 0.5 - 1.5 17 1 KETTLE ON STAND 0.5 0.5 1.0 - DRAIN TO TRENCH DRAIN W/ AIR GAP. 18 1 WORKTABLE W/ SINK 0.5 0.5 1.5 - DRAIN TO FLOOR SINK W/ AIR GAP. 19 1 3-COMPARTMENT SINK 0.5 0.5 1.5 - DRAIN TO FLOOR SINK W/ AIR GAP. W/ SPRAYER. 20 1 ICE MAKER W/ BIN - 0.5 1.0 - DRAIN TO HUB DRAIN W/ AIR GAP. W/ CV-1 & SHOCK ARRESTOR. 26 1 BAG-IN-BOX SYSTEM - 0.5 1.0 - LOCATE AT 18" AFF. W/ CV-1 & SHOCK ARRESTOR. DRAIN TO HUB DRAIN W/ AIR GAP. 26A 1 BAG-IN-BOX SYSTEM - 0.5 - - LOCATE AT 24" AFF. W/ CV-1 & SHOCK ARRESTOR. 36 1 DISHWASER 0.75 - 1.0 - DRAIN TO FLOOR SINK W/ AIR GAP. W/ CV-1 & SHOCK ARRESTOR. PLUMBING NOTES PROVIDE TV-1 NOTE: P.C. TO VERIFY EXACT TYPE, QTY, LOCATION OF EQUIPMENT PLUMBING CONNECTIONS BEFORE BEGINNING WORK. P.C. RESPONSIBLE FOR PROVIDING AND INSTALLING ALL REQUIRED FITTINGS, ACCESSORIES AND SIMILAR. FINAL CONNECTION TO EQUIPMENT BY P.C. TEMPERATURE AND PRESSURE RELIEF VALVE G UNION (TYP) GENERAL NOTES - THIS SHEET GAS SHUT-OFF VALVE DISCHARGE FULL SIZE OF VALVE DISCHARGE. ROUTE DISCHARGE TO MOP SINK. WH-1 6" DIRT LEG HB PLATFORM 1. ITEMS SHOWN IN FAINT & HATCHED ARE TO BE DEMO'D OR RELOCATED. ITEMS SHOWN IN FAINT ARE EXISTING TO REMAIN. NEW OR RELOCATED ITEMS ARE SHOWN IN BOLD. SEE LEGEND. P.C. TO VERIFY EXACT SIZE, LOCATION, INVERT & DIRECTION OF EXISTING LINES BEFORE BEGINNING WORK. P.C. TO VERIFY THAT NO FIXTURES ARE CONNECTED UPSTREAM OF BACK FLOW PREVENTER. 2. WATER HEATER ON PLATFORM BY G.C. SIZE PER LOCAL SIESMIC REQUIREMTNS AND TOTAL WEIGHT OF WATER HEATER FULL OF WATER. 3. 1" DRAIN LINE TO CAN WASH. TAGGED NOTES - THIS SHEET NOTE: 1. INSTALL H.W. HEATER PER MANUFACTURER RECOMMENDATION. 2. PROVIDE HEAT TRAP ON CW AND HW LINES PER ENERGY CODE. WATER HEATER DETAIL 2 1 1-1/2" CW UP FR SLAB. PROVIDE SHUT-OFF VALVE. 2 PROVIDE TEMPERING VALVE, TV-1, UNDER SINK. SET TO NO SCALE 6/16/14 maple STORAGE ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 MEN plumbing mechanical electrical 2 P-1 P-2 HALL WOMEN DINING AREA 4 DINING AREA 3 DINING AREA 2 2 P-1 BACK HALL P-2 CAN WASH WH-1 ABV CAN WASH TO GO ORDERS CUSTOMER QUEUE 26A P-3 HWR TO RP-1 @ WH-1 FRONT KITCHEN OFFICE 20 EXIST. 1-1/2" CW FR METER 2 HB 1 BFP-1 10 2 10 DINING AREA 1 10 36 CATERING STORAGE 2 19 HB 18 17 Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 PREP KITCHEN/ DRY STORAGE 26 1 PLUMBING PLAN - WATER SCALE: 1/4" = 1'-0" P-2 PLUMBING PLAN WATER FIRE RATING LEGEND 1-HR WALL QTY. DESCRIPTION COLD WATER SIZE (IN.) INDIR. DRAIN SIZE (IN) DIRECT DRAIN SIZE (IN) 10 3 HAND SINK 0.5 0.5 - 1.5 13 2 HOT FOOD COUNTER - - 1.5 - DRAIN TO FLOOR SINK W/ AIR GAP. 17 1 KETTLE ON STAND 0.5 0.5 1.0 - DRAIN TO FLOOR SINK W/ AIR GAP. 18 1 WORKTABLE W/ SINK 0.5 0.5 1.5 - DRAIN TO FLOOR SINK W/ AIR GAP. 19 1 3-COMPARTMENT SINK 0.5 0.5 1.5 - DRAIN TO FLOOR SINK W/ AIR GAP. W/ SPRAYER. 20 1 ICE MAKER W/ BIN - 0.5 1.0 - DRAIN TO HUB DRAIN W/ AIR GAP. W/ CV-1 & SHOCK ARRESTOR. DRAIN LINE, SUPPORT ABV HUB AIR GAP HUB ADAPTER FLOOR TO DRAIN DEEP SEAL TRAP 5 ITEM # HOT WATER SIZE (IN.) EQUIPMENT SCHEDULE HUB DRAIN DETAIL PLUMBING NOTES PROVIDE TV-1 21 1 ICE DISPENSER - - 1.0 - DRAIN TO HUB DRAIN W/ AIR GAP. 26 1 BAG-IN-BOX SYSTEM - 0.5 1.0 - (2) 0.5" CW CONNECTIONS. LOCATE AT 18" AFF & 24" AFF. W/ CV-1 & SHOCK ARRESTOR. 36 1 DISHWASER 0.75 - 1.0 - DRAIN TO FLOOR SINK W/ AIR GAP. W/ CV-1 & SHOCK ARRESTOR. NOTE: P.C. TO VERIFY EXACT TYPE, QTY, LOCATION OF EQUIPMENT PLUMBING CONNECTIONS BEFORE BEGINNING WORK. P.C. RESPONSIBLE FOR PROVIDING AND INSTALLING ALL REQUIRED FITTINGS, ACCESSORIES AND SIMILAR. FINAL CONNECTION TO EQUIPMENT BY P.C. NO SCALE STACK, VENT, OR END CAP. SEE PLAN/RISER. STRAINER THREADED CLEANOUT PLUG COVER PLATE WITH SECURING SCREW (APPX. 18" AFF) SEE NOTE TEST TEE TOP OF QUARRY TILE FLUSH WITH TOP OF DRAIN GRATE GRATE - SEE FIXTURE SCHEDULE FOR TYPE 1. FINISHED FLOOR DOME STRAINER ITEMS SHOWN IN FAINT & HATCHED ARE TO BE DEMO'D OR RELOCATED. ITEMS SHOWN IN FAINT ARE EXISTING TO REMAIN. NEW OR RELOCATED ITEMS ARE SHOWN IN BOLD. SEE LEGEND. P.C. TO VERIFY EXACT SIZE, LOCATION, INVERT & DIRECTION OF EXISTING LINES BEFORE BEGINNING WORK. 2. TAGGED NOTES - THIS SHEET 6" MIN. FINISHED WALL GENERAL NOTES - THIS SHEET FLASHING COLLAR SEEPAGE HOLES 1 PORTION OF BRANCH LINE IS PART OF CIRCUIT VENT SYSTEM, MAXIMUM SLOPE 8%. TURN DOWN AS NECESSARY AFTER MOST DOWNSTREAM FIXTURE. IF SLOPE REQ'S CANNOT BE MAINTAINED ADDITIONAL VENTS WILL BE REQUIRED. 2 BRANCH DRAIN FROM TRENCH DRAIN TO BE CAST 3 REMOVE & REPLACE IF NECESSARY FOR FLOOR INSTALLATION. TO DRAIN NOTE: EXTEND TEST TEE OPENING IF PLUG IS GREATER THAN 8" FROM FINISHED WALL. SEE FLOOR PLAN FOR PIPE SIZE WALL CLEANOUT DETAIL 4 3 NO SCALE FLOOR SINK DETAIL FLOOR DRAIN DETAIL 2 NO SCALE NO SCALE 4 COORD. EXACT LOCATION OF TRENCH DRAIN W/ OWNER & KETTLE POSITION. STORAGE maple MEN VENT & WCO 6/16/14 ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 P-1 P-2 plumbing mechanical electrical HALL 1 WOMEN P-1 TO EXIST. 2,000 GAL. GREASE SEPERATOR DINING AREA 4 DINING AREA 3 P-2 3 GW GW GW EXIST. FCO TO GO ORDERS NOTE: P.C. TO VERIFY EXISTING LINES. P.C. TO TAKE ALL MEASURES POSSIBLE TO ENSURE GREASY WASTE AND SANITARY SEWER SYSTEMS DO NOT BECOME INTERCONNECTED. P.C. RESPONSIBLE FOR ANY INTERCONNECTION THAT OCCURS. CUSTOMER QUEUE CAN WASH BACK HALL 2" HD 26 3" FS P-3 13 3" FD OFFICE EXIST. 4" TO S.S. DINING AREA 2 13 3" FD FRONT KITCHEN EXIST. FCO 3 20 21 1 10 2" HD 10 DINING AREA 1 19 17 18 36 CATERING STORAGE 10 3" FS 3" FD VENT & WCO 2 3" FS 4 PREP KITCHEN/ DRY STORAGE 3" TD Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 P-3 EXIST. 4" GREASY WASTE 1 PLUMBING PLAN - WASTE SCALE: 1/4" = 1'-0" PLUMBING PLAN WASTE 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 2 1 METALLIC PIPE (GYPSUM WALL) DETAIL plumbing mechanical electrical NO SCALE WASTE/VENT RISER NO SCALE Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 P-4 PLUMBING RISERS FIRE RATING LEGEND 1-HR WALL PIPING PIPE CLAMPS: "UNISTRUT" #P2600 WITH CUSHION BETWEEN PIPING & CLAMP. SIZE TO MATCH PIPING SIZE EQUAL TO PIPE PIER: CLOSED CELL BLACK POLYETHYLENE FOAM, 14 GAUGE CHANNEL STRUT ROOF WALK PAD BELOW SUPPORT PER ROOF MFG. REQMT'S. NATURAL GAS CALCULATIONS TABLE 402.4(3) NOTE: MAX CAPACITY OF PIPE IN MBH SUPPORT PIPE AT MAXIMUM OF 6'-0" O.C. SEE ARCH. DWGS. FOR ROOF PENETRATION DETAILS. 5 BY P.C. BY M.C. NOTE: PROVIDE REGULATOR AT EACH ROOF TOP UNIT TO PROVIDE GAS PRESSURE AND CAPACITY AS REQUIRED BY UNIT MANUFACTURER GAS PIPING SUPPORT DETAIL NO SCALE ROOF TOP UNIT SHUT-OFF VALVE PIPE SIZE (IN.) EQUIV. LENGTH = 325 FT ?? FT ?? FT 1/2" 243 MBH ?? MBH ?? MBH 3/4" 507 MBH ?? MBH ?? MBH 1" 907 MBH ?? MBH ?? MBH BASED UPON CHAPTER 4 OF THE 2012 NORTH CAROLINA FUEL GAS CODE, 2.0 PSI INLET PRESSURE, 1.0 PSI PRESSURE DROP. PITCH BACK TO SOURCE UNION (OPTIONAL). CONFIRM W/ MFG'S INSTRUCTIONS. ROOF GAS CONNECTION DETAIL NO SCALE 1 CHAR-BROILER 0.75 72.0 1 2-BURNER RANGE W/ GRIDDLE 0.75 138.0 1 COUNTER TOP GRIDDLE 0.75 84.0 GAS PIPE SUPPORT DIRT LEG 3 DESCRIPTION GAS LINE SIZE (IN) 12" MAX. FLEX CONNECTION FROM SHUT-OFF VALVE(S) & REGULATOR 2 GAS PIPING RTU CONNECTION GAS INPUT (MBTUH) EQUIPMENT SCHEDULE ITEM # QTY. 2 4 5 NO SCALE NOTE: P.C. TO VERIFY EXACT TYPE, QTY, LOCATION OF EQUIPMENT PLUMBING CONNECTIONS BEFORE BEGINNING WORK. P.C. RESPONSIBLE FOR PROVIDING AND INSTALLING ALL REQUIRED FITTINGS, ACCESSORIES AND SIMILAR. FINAL CONNECTION TO EQUIPMENT BY P.C. 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical WH-1 (199 MBH) 4 GAS DWN TO WH-1 (120 MBH) (60 MBH) GAS RISER SCALE: 1/4" = 1'-0" 5 (84 MBH) 2 (72 MBH) 4 (138 MBH) 1" GAS LINE DWN THRU ROOF. EXTEND 3/4" LINE ON TO COOKLINE W/ GSV-1 IN RISER. OPPOSITE END OF BUILDING GENERAL NOTES - THIS SHEET APPX. 110' 1 GAS FR BLW GRADE TO EXIST. GAS HEADER NEW GAS METER W/ 2.0 PSI REGULATOR. COORDINATE LOCATION WITH UTILITY. TOTAL LOAD = 823 MBH. EQUIVALENT LENGTH = 325 FEET. GAS PIPING PLAN 1. SCALE: 1/4" = 1'-0" 2. 3. P.C. IS TO PROVIDE REGULATOR, FLEX CONNECTION & SHUT-OFF VALVE AT EACH EQUIPMENT CONNECTION. COORDINATE AND VERIFY EXACT SIZE AND LOCATION OF EQUIPMENT GAS CONNECTION(S) BEFORE BEGINNING WORK. PROVIDE LABELING ON GAS PIPING AS REQUIRED BY 2012 NCFGC SEC. 401.5 & 401.7. P.C. IS RESPONSIBLE FOR VENTING REGULATORS TO EXTERIOR AS REQ'D. Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 P-5 GAS PLAN & RISER PACKAGED DX COOLING/GAS-ELEC HEATING ROOF TOP UNIT SCHEDULE HVAC GENERAL NOTES EVAPORATOR FAN DATA I. GENERAL REQUIREMENTS: 5. NO FLEXIBLE DUCT ALLOWED FOR NEGATIVE PRESSURE EXHAUST APPLICATIONS. 1. 6. ALL SUPPLY AND RETURN DUCTWORK AND PLENUMS SHALL BE INSULATED. INSULATION OF DUCTWORK IN UNCONDITIONED SPACE SHALL BE MINIMUM R-5 PER 2012 NCECC. INSULATION OF DUCTWORK OUTSIDE BUILDING THERMAL ENVELOPE (I.E. ROOF, ATTIC, CRAWLSPACE) SPACE SHALL BE MINIMUM R-8 PER 2012 NCECC. 2. 3. 4. 5. MECHANICAL CONTRACTOR IS TO FURNISH AND PAY FOR ALL LABOR, MATERIAL, EQUIPMENT, PERMITS & FEES REQUIRED FOR THE COMPLETE INSTALLATION OF ALL SYSTEMS IN THIS SECTION OF WORK. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH NC MECHANICAL CODES AND ALL OTHER APPLICABLE CODES. MC IS TO COORDINATE W/ G.C. IN REGARDS TO PROJECT TIMELINE, WORK HOURS, AS WELL AS ANY BONDING OR INSURANCE REQUIREMENTS. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED COMPLETE WITH ALL ACCESSORIES, HANGERS, SUPPORTS, CONTROLS, ETC FOR A FULLY FUNCTIONING SYSTEM REGARDLESS OF PRESENCE ON PLANS. ALL EQUIPMENT, MATERIALS AND INSTALLATION SHALL BE GUARANTEED TO BE FREE OF DEFECTS FOR A PERIOD OF ONE (1) YEAR AFTER FINAL ACCEPTANCE OF WORK OR IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD GUARANTEE, IF LONGER. ALL COMPRESSORS ARE TO INCLUDE FIVE (5) YEAR WARRANTY. EXISTING EQUIPMENT IS EXCLUDED FROM WARRANTY REQUIREMENT. THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL LOCATION AND ARRANGEMENT OF ALL MATERIALS AND EQUIPMENT. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS BUILDING CONSTRUCTION AND ALL OTHER WORK WILL PERMIT. 6. DO NO SCALE DRAWINGS FOR MEASUREMENT. 7. ALL DUCT DIMENSIONS SHOWN ARE INTERIOR DUCT DIMENSIONS. 8. 9. INFORMATION GIVEN IN SCHEDULES INCLUDES BOTH DESCRIPTION OF PRODUCT AND MANUFACTURER'S MODEL #. IF CONFLICT IS PRESENT BETWEEN DESCRIPTION AND MODEL #, EQUIPMENT DESCRIPTION SHALL TAKE PRECEDENT. IN CASE OF CONFLICT BETWEEN THE PLANS AND NOTES/SPECIFICATIONS OR CONFLICT BETWEEN INFORMATION PRESENTED ON THE PLANS OR IN THE NOTES/SPECIFICATIONS, THEN THE MOST RESTRICTIVE SHALL TAKE PRECEDENT. BEFORE BID MC IS RESPONSIBLE FOR CLARIFYING W/ G.C. ANY CONFUSION IN REGARDS TO RESPONSIBILITY OF WORK TO BE PERFORMED OR MATERIALS TO BE PROVIDED. THE SUBMITTAL OF THE BID BY THE CONTRACTOR WILL BE HELD AS PROOF THAT THE CONTRACTOR UNDERSTANDS THOROUGHLY AND COMPLETELY THE SCOPE OF THE WORK INVOLVED, AND HAS INCLUDED ON THE BID ALL THE NECESSARY ITEMS TO CARRY OUT THIS SECTION OF WORK. 7. 8. 9. CONCEALED SHEET METAL SUPPLY & RETURN DUCT MAY BE EXTERNALLY INSULATED WITH MINERAL FIBER BOARD OR BLANKET OR MAY BE INTERNALLY INSULATED WITH ACOUSTICAL DUCT LINER. EXPOSED SPIRAL DUCTWORK DOES NOT REQUIRE INSULATION UNLESS OTHERWISE NOTED (WHEN INSTALLED IN CONDITIONED SPACE). ALL MAIN DUCTWORK (INCLUDING EXHAUST) TO BE SEALED ACCORDING TO 2012 NCECC AND AT A MINIMUM INCLUDE SEALING OF ALL DUCT SEAMS W/ NON-HARDENING MASTIC. SEALING BY TAPE ALONE NOT ALLOWED. CONDENSATE DRAIN PIPING AND FITTINGS SHALL BE SCHEDULE 40 PVC. DRAINS FROM AIR HANDLING UNITS SHALL BE TRAPPED (2" MINIMUM). TRAPS ON INTERIOR OF BUILDINGS TO BE INSULATED. 10. KITCHEN HOOD EXHAUST DUCT SHALL BE 16 GAUGE CARBON STEEL OR 18 GAUGE STAINLESS STEEL. ALL JOINTS AND SEAMS SHALL BE CONSTRUCTED WITH A CONTINUOUS LIQUID-TIGHT EXTERNAL WELD. PRE-APPROVED U.L. LISTED FACTORY BUILD EXHAUST SYSTEM (SUBMIT FOR APPROVAL BY ENGINEER BEFORE PURCHASE). COOLING SECTION OA, MAX OA, MIN ESP MOTOR (CFM) (CFM) (" OF WG) (HP) UNIT TAG AREA SERVED FAN CFM RTU-1 DINING 3000 - 700 0.55" RTU-2 DINING 2000 - 400 RTU-3 KITCHEN 4000 - 1000 FAN RPM AMBIENT ENT. AIR TOTAL (MBH) SENS. (MBH) # OF STAGES REHEAT (MBH) INPUT (MBH) 3.0 MFG. 93/76 80/67 89.0 67.3 1 60.6 120.0 96.0 N/A 0.58" 1.0 MFG. 93/76 80/67 62.3 48.1 1 N/A 60.0 48.0 0.69" 3.75 MFG. 93/76 80/67 119.0 92.7 2 N/A 150.0 120.0 ELECTRICAL DATA OUTPUT ELEC HEAT # OF (MBH) (KW) STAGES VOLTAGE (V/PH) GENERAL DATA MCA (A) MOCP (A) MANUF. MODEL NOM. EER TON. (SEER) WT. (LBS) 1 44.0 60 TRANE YSC090 7.5 11.2 784 1,2,3,4,5,6,7,8,9 N/A 1 29.5 45 TRANE YSC060 5.0 11.0 962 1,2,3,4,5,6,8,9 N/A 2 49.6 60 TRANE YSC120 10.0 11.3 1291 1,2,3,4,5,6,8,9 NOTES NOTES: 1. COOLING CAPACITIES ARE RATED IN ACCORDANCE WITH AT LEAST ONE OF THE FOLLOWING ARI STANDARDS; 5. W/ FACTORY MOUNTED DISCONNECT. 6. W/ FACTORY POWERED GFI CONVENIENCE RECEPTACLE. 7. W/ REHEAT COIL/HUMIDITY CONTROL. SET TO 45% RH. 8. W/ THRU THE BASE ELECTRICAL CONNECTION. 9. RTU SUPPLY FAN TO BE INTERLOCKED W/ HOOD OPERATION. TEMP., AND AIR QUANTITY LISTED BY MFG. 2. PROVIDE MANUFACTURER'S 7 DAY PROGRAMMABLE THERMOSTAT W/ REMOTE SENSOR. 3. PROVIDE 3 SETS OF NEW FILTERS FOR EACH UNIT. PROVIDE ONE AT INSTALLATION, ONE PRIOR TO AIR BALANCE AND ONE AT TURNOVER TO OWNER. 4. PROVIDE FACTORY ROOF CURB AND AIR SIDE DIFFERENTIAL ENTHALPY ECONOMIZER SECTION WITH BAROMETRIC RELIEF DAMPER FOR EACH UNIT. 11. "FIRE WRAP" OR OTHER CLEARANCE REDUCING INSULATION INSTALLED ON GREASE EXHAUST DUCT TO BE EQUAL TO "3M FIRE BARRIER DUCT WRAP 615+". 12. VENT MATERIAL SERVING ANY GAS FIRED APPLIANCE TO BE LISTED & LABELED, PER MFG'S INSTRUCTIONS AND 2012 NC MECHANICAL CODE. IF CONFLICT IS NOTED CONTACT ENGINEER. HEATING SECTION NOTE: HUMIDITY CONTROL/REHEAT MUST BE PROVIDED TO AVOID DUCT SWEATING IN DINING AREA. FAN SCHEDULE UNIT NO. SERVICE AREA SERVED CFM S.P. RPM EF-1 EXHAUST BATHROOM 150 0.23" MFG DOWNBLAST, CENTRIFUGAL 1/60 HP FF-1 AIR CURTAIN BACK DOOR 2550 N/A 1750 OVERDOOR, CENTRIFUGAL 1/2 HP 13. PLASTIC PIPE IS NOT ACCEPTABLE FOR GAS FIRED APPLIANCE VENTING UNLESS PIPING IS LISTED & LABELED FOR SUCH INSTALLATIONS. 14. ALL DAMPERS TO INCLUDE SET SCREW OR SIMILAR FEATURE FOR LOCKING IN POSITION. TYPE & MIN. MOTOR HP ARRANGEMENT & VOLTAGE MANUFACTURER & MODEL NO. GREENHECK G-070-G MARS N36-1U DRIVE CONTROL SCHEME DIRECT A 1,2,3,4,5.6 DIRECT B 4,7 NOTES: 15. ALL FIRE SEALANTS TO BE U.L. LISTED AND APPROVED FOR USE W/ APPROPRIATE U.L. PENETRATION DETAIL. 16. ALL PROGRAMMABLE THERMOSTATS TO INCLUDE BATTERY BACK-UP AND HAVE NOTES MECHANICAL LEGEND CONTROL OPTIONS: 1. SCREEN 4. INTEGRAL DISCONNECT SWITCH 2. BACKDRAFT DAMPER 5. PROVIDE WITH FACTORY ROOF CURB 3. COLOR BY ARCHITECT 6. SPEED CONTROLLER 7. A. CONTROL W/ ROOM LIGHTS (COORD. W/ E.C.) B. CONTROL W/ DOOR SWITCH W/ DOOR SWITCH 18x14 RECTANGULAR DUCT ROUND METAL DUCT FLEX/RIGID ROUND DUCT 10. AS SOON AS POSSIBLE (AND NOT MORE THAN 30 DAYS) AFTER CONTRACT IS SIGNED, THE MC SHALL PROVIDE SUBMITTALS OF MECHANICAL EQUIPMENT HE/SHE INTENDS TO PURCHASE FOR REVIEW AND COMMENT BY THE ENGINEER. ENGINEER IS TO APPROVE SUBMITTALS BEFORE EQUIPMENT IS ORDERED. IV. COORDINATION: 1. 11. ALL QUESTIONS MUST BE SUBMITTED IN RFI FORMAT TO THE ARCHITECT AND MUST BE ADDRESSED BY THE APPROPRIATE DESIGNER OF RECORD PROIR TO BECOMING A PROPOSED CHANGE ORDER. 2. 12. UPON COMPLETION OF WORK M.C. IS TO PROVIDE OWNER W/ COMPLETE BOUND SET OF ALL EQUIPMENT OPERATION & MAINTENANCE MANUALS. PACKAGE IS ALSO TO INCLUDE AND WARRANTY & GUARANTEE INFORMATION. 1. 2. 3. 4. ALL ROOF WORK INCLUDING PENETRATIONS, OPENINGS, FLASHING, CURB INSTALLS, ETC ARE TO BE PERFORMED BY ROOFING CONTRACTOR. M.C. RESPONSIBLE FOR PROVIDING ANY ROOF CURBS, EQUIPMENT RAILS, VENTS, ETC AND COMMUNICATING ALL REQ'S WITH G.C. & ROOFING CONTRACTOR. M.C. TO COORDINATE LOCATION OF ALL ROOF PENETRATIONS W/ ROOFING CONTRACTOR. P.C. & M.C. TO COORDINATE TO ENSURE NO PLUMBING VENTS OR ANY OTHER SOURCES OF BUILDING EXHAUST ARE LOCATED WITHIN 10' OF ANY OUTSIDE AIR INTAKES. ALL MATERIALS INSTALLED IN RETURN PLENUM ARE TO BE PLENUM RATED. 3. PROVIDE HANGERS & SUPPORTS APPROVED FOR USE BY 2012 NC MECHANICAL CODE. ALL MAIN DUCTWORK (SUPPLY, RETURN, EXHAUST, OUTSIDE AIR) SHALL BE GALVANIZED SHEET METAL CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS. RUNOUTS FROM MAIN/BRANCH DUCTS MAY BE FLEXIBLE DUCT CONFORMING TO THE REQUIREMENTS OF UL 181 FOR CLASS 1 FLEXIBLE AIR DUCTS. MAX. LENGTH OF FLEX PER RUNOUT TO BE 6'-0" UNLESS SHOWN OTHERWISE. N/A B AS NOTED AS NOTED 24x12 DUCT MTD. DBL. DEFL. LAY-IN PERF. SERVICE FINISH MANUFACTURER & MODEL NO. VOLUME DAMPER NOTES SUPPLY TAP WITH VOLUME DAMPER YES WITH EXTRACTOR ALUM. SUPPLY NOTE 2 TITUS S300FS NO ALUM. SUPPLY NOTE 2 TITUS PAS-AA 1,2,3 SUPPLY TAP 6/16/14 1,2,3 ALUM. SUPPLY NOTE 2 TITUS PAS-AA 1,2,3 D AS NOTED N/A AS NOTED SURFACE LOUVERED NO STEEL RETURN NOTE 2 TITUS 350RL 1,2,3 EXHAUST REGISTER/GRILLE OR RISER V. EXECUTION: E AS NOTED AS NOTED 24x12 LAY-IN PERF. NO ALUM. RETURN NOTE 2 TITUS PAR-AA 1,2,3 SIDEWALL DIFFUSER/GRILLE 1. F AS NOTED N/A 24x12 LAY-IN PERF. NO ALUM. EXHAUST NOTE 2 TITUS PAR-AA 1,2,3 H AS NOTED AS NOTED 24x12 LAY-IN PERF. NO ALUM. HOOD SUPPLY NOTE 2 TITUS PAR-AA 1,2,3,4 M.C. TO FOLLOW MANUFACTURER'S INSTRUCTIONS WHEN INSTALLING MECHANICAL EQUIPMENT. ENSURE REQUIRED MAINTENANCE ACCESS AND CLEARANCES ARE MAINTAINED. IF CONFLICT EXISTS BETWEEN THESE PLANS AND MFG INSTRUCTIONS CONTACT ENGINEER. RETURN REGISTER/GRILLE OR RISER CEILING EXHAUST FAN T maple T-STAT ENGINEERING, pllc 2. ALL PENETRATIONS THROUGH EXTERIOR WALLS & ROOF SHALL BE FLASHED & COUNTER-FLASHED IN A WATERPROOF MANNER. INDEPENDENT CERTIFIED TEST AND BALANCE CONTRACTOR SHALL BALANCE SYSTEM TO AIR QUANTITIES INDICATED ON PLANS AND IN ACCORDANCE W/ 2012 NCECC SEC. 503.2.9. M.C. TO PROVIDE OWNER'S REPRESENTATIVE & ENGINEER WITH COMPLETE BALANCE REPORT. MC RESPONSIBLE FOR PROVIDING ANY DAMPERS, VALVES, PORTS, ETC. NECESSARY FOR A COMPLETE SYSTEM BALANCE. 6. PENETRATIONS OF NON-RATED WALLS, PARTITIONS AND FLOOR OF COMBUSTIBLE CONSTRUCTION SHALL BE FIRESTOPPED WITH MATERIALS EQUIVALENT TO TWO INCHES OF WOOD. FIRESTOPPING SHALL COMPLY WITH ASTM E-814. 7. ANY NOTCHING, DRILLING, BORING OR OTHER ALTERATION TO BUILDING STRUCTURE SHALL BE PERFORMED IN A CODE APPROVED METHOD AND NOT THREATEN THE INTEGRITY OF THE BUILDING STRUCTURE. III. MATERIALS: 2. AS NOTED DAMPER MATERIAL NO 5. ALL MATERIALS SHALL BE NEW UNLESS OTHERWISE SHOWN OR SPECIFIED. AS NOTED PATTERN PERF. MECHANICAL CONTRACTOR IS TO EMPLOY THE SERVICES OF THE G.C. FOR CUTTING AND PATCHING OF WALLS, FLOORS & CEILINGS RELATED TO THE INSTALLATION OF MECHANICAL EQUIPMENT & SYSTEMS. 1. A FRAME TYPE LAY-IN INSTALL ALL CONTROL DEVICES, INCLUDING THERMOSTATS AND SWITCHES, 4'-0" ABOVE FINISHED FLOOR. WATER HEATER VENT BY MECHANICAL CONTRACTOR. MODULE SIZE 24x24 4. 6. NECK SIZE AS NOTED SEAL ALL PENETRATIONS OF RATED WALLS, CEILING, FLOORS IN ACCORDANCE W/ APPROPRIATE U.L. PENETRATION DETAIL. ALL GAS PIPING IS BY PLUMBING CONTRACTOR. CFM AS NOTED 3. 5. 4. MECHANICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL PENETRATIONS FOR RELIEF HOODS, OUTSIDE AIR HOODS, LOUVERS, AND WALL CAPS WITH ARCHITECT & OWNER PRIOR TO INSTALLATION. ALL LOW VOLTAGE WIRING RELATED TO MECHANICAL EQUIPMENT AND SYSTEMS IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR (ANY LOW VOLTAGE FIRE ALARM WIRING TO BE BY E.C.). ALL HIGH VOLTAGE CONNECTIONS TO MECHANICAL EQUIPMENT, TO BE PROVIDED AND INSTALLED BY E.C. (SEE EQUIPMENT SCHEDULE FOR DISCONNECT RESPONSIBILITY). G.C. RESPONSIBLE FOR PAINTING OF ANY EXPOSED DUCT, PIPING, GRILLES, ETC. M.C. RESPONSIBLE FOR CLEANING AND PREPARING ITEMS FOR PAINT, COORDINATE W/ G.C. SYMBOL C 13. M.C. IS TO PROVIDE TRAINING TO OWNER OR OWNER'S REPRESENTATIVE IN REGARDS TO OPERATION, FUNCTION, AND MAINTENANCE OF ALL MECHANICAL EQUIPMENT, CONTROLS, ETC. II. DIVISION OF WORK: DIFFUSER SCHEDULE SUPPLY DIFFUSER/GRILLE OR RISER 3. 14. M.C. IS TO REVIEW COMPLETE DRAWING SET. M.C. IS RESPONSIBLE FOR WORK EXPLICITLY SHOWN AND WORK IMPLIED. THE MECHANICAL CONTRACTOR SHALL COORDINATE CLOSELY WITH ALL OTHER TRADES TO AVOID CONFLICT AND ENSURE OTHER TRADES PROVIDE MEASURES TO ACCOMMODATE MECHANICAL WORK (I.E. ACCESS DOORS, SLAB/WALL/ROOF OPENINGS, ELECTRICAL CONNECTIONS, ETC). ELBOW WITH TURNING VANES 8. 9. SUPPORT ALL DUCTWORK AND PIPING IN ACCORDANCE W/ 2012 NC MECHANICAL CODE. ANY SUSPENDED MATERIALS SHALL BE DIRECTLY SUPPORTED BY THE BUILDING STRUCTURE. PENETRATIONS OF ALL EXTERIOR WALLS, FLOORS AND CEILINGS SHALL BE SEALED IN AN AIR TIGHT MANNER AND IN ACCORDANCE W/ 2012 NCECC APPENDIX 2 DETAILS. ALL PENETRATIONS OF WALLS, FLOORS & CEILINGS IN RETURN OR EXHAUST PLENUMS SHALL BE SEALED IN AN AIR TIGHT MANNER. 10. DUCT ACCESS DOORS TO BE PROVIDED AT ALL FIRE, RADIATION & SMOKE DAMPERS, SMOKE DETECTORS, CLEANOUTS AND ANY OTHER CODE REQUIRED LOCATIONS. 11. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL MECHANICAL EQUIPMENT FROM FOREIGN MATERIAL DURING CONSTRUCTION (PAINT, SPACKLE, ETC.). UPON COMPLETION OF WORK THE MECHANICAL CONTRACTOR SHALL CLEAN, WASH, ETC ALL ITEMS AND EQUIPMENT WITHIN HIS SCOPE OF WORK AND LEAVE ALL ITEMS BRIGHT AND CLEAN. NOTES: GENERAL - MC RESPONSIBLE FOR VERIFYING QTY, COLOR & FRAME TYPE OF DIFFUSERS/GRILLES BEFORE ORDERING. PROVIDE SQR TO RND TRANSTIONS & PLENUMS AS NECESSARY. 2. FINISH TO MATCH / BE ABLE MATCH CEILING OR WALL OR DOOR. 3. FACTORY INSULATION BACKING ON GRILLES EXPOSED TO NON-CONDITIONED AREAS. ALTERNATELY, FIELD SUPPLY AND INSTALL. 1. 4. RETURN GRILLE TO BE USED AS A SUPPLY DEVICE FOR "AIR-DROP" EFFECT. DIFFUSER DESIGNATIONS ON PLANS AS FOLLOWS: DIFFUSER OR DIFFUSER TYPE NECK SIZE. 8x4 AS NOTED ABOVE A 75 AIR QUANTITY SD DUCT SMOKE DETECTOR AV AUDIO/VISUAL ALARM (W/ REMOTE TEST KEY SWITCH) S REMOTE TEMP SENSOR P REMOTE PULL STATION 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical 3/4" DOOR UNDER CUT EXISTING EQUIP. OR DUCT TO BE REMOVED ENERGY REQUIREMENTS: MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT NOTE: SEE HOOD & FAN DRAWINGS FOR ADDITIONAL INFO. METHOD OF COMPLIANCE PRESCRIPTIVE ENERGY COST BUDGET THERMAL ZONE 4A EXTERIOR DESIGN CONDITIONS WINTER DRY BULB SUMMER DRY BULB 14 93 INTERIOR DESIGN CONDITIONS WINTER DRY BULB SUMMER DRY BULB RELATIVE HUMIDITY 70 76 50% BLDG 1 BUILDING HEATING LOAD (MBH) 145.9 BUILDING COOLING LOAD (MBH) 243.3 MECHANICAL SPACING CONDITIONING SYSTEM UNITARY DESCRIPTION OF UNIT HEATING EFFICIENCY COOLING EFFICIENCY HEAT OUTPUT OF UNIT COOLING OUTPUT OF UNIT BOILER TOTAL BOILER OUTPUT CHILLER TOTAL CHILLER OUTPUT LIST EQUIPMENT EFFICIENCIES SEE SCHEDULES SEE SCHEDULES SEE SCHEDULES SEE SCHEDULES SEE SCHEDULES NA NA SEE SCHEDULES DESIGNER'S STATEMENT: TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS BUILDING COMPLIES WITH THE MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT REQUIREMENTS OF THE N.C.S. ENERGY CODE. SIGNED: NAME: ZACK L. TOMLIN, PE TITLE: MECHANICAL ENGINEER Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 M-1 MECHANICAL SCHEDULES DETAILS & NOTES FIRE RATING LEGEND 1-HR WALL GENERAL NOTES - THIS SHEET 1. 2. 3. 4. 5. TAGGED NOTES - THIS SHEET ITEMS SHOWN IN FAINT & HATCHED ARE TO BE DEMO'D OR RELOCATED. ITEMS SHOWN IN FAINT ARE EXISTING TO REMAIN. NEW OR RELOCATED ITEMS ARE SHOWN IN BOLD. SEE LEGEND. ENSURE THAT ALL SOURCES OF BUILDING EXHAUST ARE A MINIMUM OF 10' HORIZONTALLY FROM OR A MINIMUM OF 3' ABOVE ANY AREA OUTSIDE AIR INTAKES. M.C. TO SEE HOOD & FAN DRAWINGS FOR ADDITIONAL INFORMATION. M.C. TO SEE ROOF PLAN FOR ADDITIONAL INFORMATION. CENTERLINE OF EXPOSED DUCTWORK TO BE AT EQUAL ELEVATION. CONFIRM ELEVATION W/ ARCHITECT. 1 3/4" DOOR UNDERCUT. 2 PROVIDE DUCT MOUNTED SMOKE DETECTOR. SEE DETAIL. 3 8x8 EXHAUST DUCT UP TO FAN ON ROOF. 4 COORDINATE EXACT LOCATION OF ROOF EQUIPMENT W/ STRUCTURE BELOW. 5 INSTALL WATER HEATER VENT TO ROOF. SIZE AND INSTALL PER WATER HEATER MFG'S INSTRUCTIONS. 6 REMOVE EXISTING SHELL SPACE UNIT HEATER. TURNOVER TO LANDLORD. 7 PROVIDE DRAIN FROM COOLER EVAPORATOR TO GRADE AWAY FROM FOOT TRAFFIC. 8 REMOTE PULL STATION FOR HOOD FIRE SUPPRESSION SYSTEM. SEE DETAIL. COORD. EXACT LOCATION W/ LOCAL AHJ. 9 NO CEILING AT WATER HEATER. COORDINATE W/ G.C.. 10 RETURNS ON BULKHEAD. MOUNT AS HIGH AS POSSIBLE. 11 SUPPLY DIFFUSERS HIDDEN FROM VIEW BY RTU-1. SEE FRONT KITCHEN MECHANICAL PLAN FOR MORE DETAIL. 12 FLY FAN ABOVE REAR DOOR. 13 18x16 DN FROM KSF ON ROOF. PROVIDE MITERED ELBOW W/ TURNING VANES AT VERTICAL TO HORIZONTAL BEND. 14 10x10 GREASE EXHAUST DOWN TO HOOD. TRANSITION AT HOOD AS NECESSARY. 15 16x16 GREASE EXHAUST DOWN TO HOOD. TRANSITION AT HOOD AS NECESSARY. 16 SUPPLY TAP DOWN TO HOOD CONNECTION. COORDINATE EXACT QTY, SIZE AND CFM OF TAPS W/ HOOD MFG AND DRAWINGS. TYPICAL. 17 SEE ENLARGED DRAWING FOR HOOD LAYOUT. EQUIPMENT SCHEDULE ITEM # QTY. DESCRIPTION 2 1 CHAR-BROILER 2.1 1 COUNTER TOP GRIDDLE 3 1 REFRIGERATED EQUIPMENT STAND 4 1 2-BURNER RANGE W/ GRIDDLE 5 1 COUNTER TOP GRIDDLE 16 1 DOUBLE DECK CONVECTION OVEN 17 1 KETTLE ON STAND 18 B 50 16 18x16 F 75 3 5 2.1 (RTU-2) C 150 DINING AREA 3 DINING AREA 4 WOMEN 1 B 50 17 18 A 12x6 300 KEF-2 18 A 12x6 300 F 16 A 24x4 400 A 24x4 400 A 12x6 300 18 C 180 WH-1 A 20x4 350 14x4 A 200 10 D 24x14 1600 EMG 12 FF-1 SCALE: 1/4" = 1'-0" BACK HALL 10 6 5 9 FRONT KITCHEN H 500 KSF-3 11 C 400 RTU-1 11 KEF-2 (RTU-1) (RTU-2) (RTU-3) (RTU-3) HD-2 DINING AREA 1 17 (HD-1&2) (RTU-1) 24x20 1 C 120 2 11 2 OFFICE 16x14 24x18 20x14 400 C 4 22x18 (2) E 750 (RTU-1) (RTU-2) (RTU-3) D 30x18 2300 24x18 4 RTU-2 PARTIAL MECH. PLAN - KITCHEN CUSTOMER QUEUE EXIST UH 20x14 8 A 24x4 400 18 A 24x4 400 H 500 7 KEF-1 CATERING STORAGE 14x14 14x14 20x18 HD-2 RTU-3 2 (2) E 750 C 200 C 200 H 300 4 A 12x6 300 18 A 12x6 300 H 300 Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 M-2 FROM RTU-3 MECH. PLAN - FRONT KITCHEN PREP KITCHEN/ DRY STORAGE HD-1 200 C SCALE: 1/4" = 1'-0" A 24x4 400 plumbing mechanical electrical 75 CAN WASH 2 18 A 24x4 400 18 TO GO ORDERS H 500 DINING AREA 2 14 HD-1 H 500 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 EF-1 18 KEF-1 3 ENGINEERING, pllc 4 2 15 HD-2 maple HALL MEN 3 KSF-3 STORAGE 1 16x14 13 6/16/14 1 MECHANICAL PLAN SCALE: 1/4" = 1'-0" MECHANICAL PLAN TAGGED NOTES - THIS SHEET 1 KSF DUCT UP/DOWN FROM SUPPLY FAN ON ROOF. 2 GREASE EXHAUST DUCT UP TO FAN ON ROOF. MAINTAIN REQ'D CLEARANCES OR WRAP DUCT, SEE DETAIL. PROVIDE WINDBAND EXTENSION(S) TO BRING EXHAUST A MINIMUM OF 3' ABOVE AREA OUTSIDE AIR INTAKES. 3 GREASE EXHAUST DUCT UP TO FAN ON ROOF. MAINTAIN REQ'D CLEARANCES OR WRAP DUCT, SEE DETAIL. PROVIDE WINDBAND EXTENSION(S) TO BRING EXHAUST A MINIMUM OF 3' ABOVE AREA OUTSIDE AIR INTAKES. 4 EXHAUST DUCT UP TO FAN ON ROOF. SEE DETAIL. 5 ENSURE THAT ROOF MOUNTED EQUIPMENT IS A MINIMUM OF 6' FROM ROOF EDGE IF PARAPET WALL IS LESS THAN 42" IN HEIGHT. GENERAL NOTES - THIS SHEET 1. 2. ENSURE THAT ALL SOURCES OF BUILDING EXHAUST ARE A MINIMUM OF 10' HORIZONTALLY FROM OR A MINIMUM OF 3' ABOVE ANY AREA OUTSIDE AIR INTAKES. M.C. TO SEE HOOD & FAN DRAWINGS FOR ADDITIONAL INFORMATION. 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 EF-1 4 plumbing mechanical electrical 5 WH-1 VENT RTU-2 RTU-1 1 KSF-3 3 2 KEF-2 KEF-1 RTU-3 Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 M-3 1 MECH. PLAN - ROOF SCALE: 1/4" = 1'-0" MECHANICAL PLAN ROOF WINDBAND EXTENSION. EXTENSION(S) TO BRING EXHAUST A MINIMUM OF 3' ABV AREA OA INTAKES. BOLTED, FLANGED, GASKETED DUCT CONNECTION. ADJUSTABLE AIR SCOOP/DAMPER. FURNISHED W/ REGISTER. VENTED CURB EXTENSION EXHAUST DUCT FLANGE FASTENED TO NAILOR ADJUSTABLE DEFLECTION BLADES (DOUBLE) FRONT BLADES PARALLEL TO SHORT DIMENSION. FLASHING G GAS PIPING ON ROOF DRIP LEG BY P.C. SD SEAL ALL DUCTWORK OPENINGS WITH NONHARDENING MASTIC. DUCT MOUNTED SMOKE PROVIDED BY E.C., INSTALLED IN DUCT BY M.C., WIRED TO BLDG FA SYSTEM BY E.C. ENSURE DETECTOR IS DOWN STREAM OF ALL RETURN TAPS, UPSTREAM OF OA CONNECTION AND WIRED TO UNIT SHUT DOWN, SPACE AV ALARM & BLDG FIRE ALARM SYSTEM. FLEX CONN. NOTED. BACK DRAFT DAMPER TWO (2) SETS OF ADJUSTABLE FINS. GRILLE HEIGHT 3" 4" 6" 8" 10" 12" FLUSH MOUNTED SUPPLY AIR REGISTER. GASKET EXHAUST DUCT SUPPLY AIR DUAL OR SINGLE WALL DUCT. 7 GAS SHUT-OFF VALVE BY PLUMBING CONTR. FLASHING LIQUID TIGHT FLEX. CONDUIT (BY E.C.) FLASHING & COUNTER-FLASHING NOTE: REGISTER(S) TO BE LOCATED AT THE 3 & 9 O'CLOCK POSITIONS. BLADE SPREAD TO BE SET 1" CONDENSATE TO SPLASH BLOCK 2" RIGID INSUL. EXH. FAN DETAIL (ROOF) 6 NO SCALE WELDED SEAM EXHAUST DUCT (W/ FIRE WRAP IF NECESSARY) 6" 8" 10" 12" 14" 16" ROOF STRUCTURE. COORDINATE OPENING SIZE W/ DUCT CLEARANCE REQ'S. NOTE: FAN DISCHARGE TO BE A MIN. OF 10' AWAY HORIZONTALLY FROM ANY NON-PARAPET PARTS OF THE BUILDING STRUCTURE AND ANY OUTSIDE AIR INTAKES. SPIRAL DUCT REGISTER (FLUSH) 5 NO SCALE PROVIDE ACOUSTIC DUCT LINER FIRST 10' FROM DISCHARGE AND INTAKE. GREASE EXHAUST FAN DETAIL 4 NO SCALE PROVIDE 3 ALT. LAYERS OF 5/8" G.W.B. & 1" RIGID INSULATION. SEAL AND STAGGER ALL SEAMS. GAS/ELECTRIC ROOFTOP UNIT NO SCALE APPROVED GRAVITY AND WIND INDUCED VENTILATOR KITCHEN HOOD NOTES 1. DRAW BAND - 16GA. BLACK STEEL OR WELDED SEAM 2. KITCHEN EXHAUST DUCT TO BE CONSTRUCTED OF MIN. 16 GAUGE STEEL. JOINTS TO BE CONTINUOUS EXTERNAL LIQUID-TIGHT WELDS. 3. EXHAUST DUCT TO SLOPE BACK TO HOOD OR APPROVED GREASE RESERVOIR. DUCT TO MAINTAIN MIN. 2% SLOPE FOR DUCT SYSTEMS 75' OR LESS IN LENGTH AND 8.3% SLOPE FOR DUCT SYSTEMS GREATER THAN 75' IN LENGTH. 11 GAUGE BLACK STEEL WELDED CONSTRUCTION ROUND TO SQUARE TRANSITION STORM COLLAR/FLASHING MIN HEIGHT = 2'-0" OR 2'-0" ABV ANY PART OF BLDG WITHIN 10'-0". WHICHEVER IS GREATER. ROOF ALL GREASE EXHAUST WORK IS TO BE DONE IN ACCORDANCE W/ 2012 NCMC SEC 506 & ALL OTHER APPLICABLE CODES. M.C. IS TO REVIEW REQUIREMENTS OF 2012 NCMC SEC 506 BEFORE BEGINNING WORK. 4. ALL BENDS TO BE RADIUS THROAT AND RADIUS BACK TYPE. CENTER LINE RADIUS 1.0 TIMES DUCT DIMENSION OR GREATER. 5. CLEANOUTS TO BE PROVIDED WITHIN 10' OF ALL CHANGES IN DUCT DIRECTION & EVERY 20' ON CENTER IN HORIZONTAL RUNS. CONSULT LOCAL CODES REGARDING ADDITIONAL CLEANOUT LOCATIONS, CLEANOUT PROTECT, SIZING, AND ORIENTATION ON DUCT. 6. INSULATION INSULATION SHIELD COORD. EXACT CLEARANCE W/ FLUE MFG ALL GREASE EXHAUST DUCT(S) IS TO BE INSTALLED PER CODE REQUIREMENTS REGARDING CLEARANCE, DUCT ENCLOSURES, AND ACCESS. 18" CLEARANCE IS TO BE MAINTAINED FROM DUCT TO SURROUNDING COMBUSTIBLE CONSTRUCTION AND 3" CLEARANCE IS TO BE MAINTAINED FROM NON-COMBUSTIBLE CONSTRUCTION (6" REQ'Q FOR DUCT ENCLOSURES). SOME CLEARANCE OR DUCT ENCLOSURE REQUIREMENTS MAY BE OMITTED THROUGH THE USE OF APPROVED DUCTWRAP/FIREWRAP. DUCTWRAP USED FOR CLEARANCE REDUCTION AROUND GREASE DUCT TO BE 2-LAYERS OF "3M FIRE BARRIER DUCT WRAP 615+" OR EQUAL, CONSULT LOCAL AHJ. NOTES: 1. EXTEND FLASHING TO "SEAM TO SEAM" FOR INSTALLATION ON STANDING SEAM METAL ROOFS. 7. ALL DUCTWRAP/FIREWRAP OR SIMILAR IS TO BE INSTALLED PER MFG. RECOMMENDATIONS. 2. ENSURE FLUE IS 10' FROM ANY BUILDING AIR INTAKES. 8. 3. FLUE MAY REQUIRE ADDITIONAL BRACING IN HIGH WIND AREAS. 4. SEAL AROUND FLUE & FLASHING AS REQUIRED. GC IS TO PROVIDE RATED ENCLOSURE (WHEN NEEDED) WITH RATED ACCESS DOORS AS REQUIRED. GC TO SPACE STRUCTURE TO ACCOMMODATE DUCTS WITH WRAP, DUCT ENCLOSURES, AND ACCESS DOORS AS NECESSARY. 9. 3 GAS FLUE DETAIL NO SCALE HOOD TO BE INSTALLED SUCH THAT CODE REQUIRED MIN. DISTANCE BETWEEN LOWEST EDGE OF GREASE FILTER(S) AND COOKING/HEATING SURFACE IS NOT VIOLATED. MIN. DISTANCE EQUALS 12" FOR SURFACES WITH NO EXPOSED FLAME, 24" FOR SURFACES WITH EXPOSED FLAME AND BURNERS & 42" FOR EXPOSED CHARCOAL AND CHARBROIL TYPE SURFACES. LOWEST EDGE OF HOOD MUST NOT BE MORE THAN 48" FROM COOKING SURFACE(S). 10. HOOD CAPTURE SIZED BASED UPON EQUIPMENT SCHEDULED TO BE UNDER HOOD PLUS MIN. 6" OVERHANG ON ALL EXPOSED SIDES PER CODE. FIELD VERIFY & COORDINATE ACTUAL FURNISHED EQUIPMENT WITH SPECIFIED HOOD SIZE. VOLUME DAMPER WITH 3/8" LOCKING QUADRANT AND END BEARING. (WHERE ACCESIBLE) SUPPLY AIR DUCT. ROUND SHEET METAL DUCT. FLEX DUCT DIAMETER "D" NOTE: FLEX DUCT TURN INTO DIFFUSER TO BE REPLACED BY INSULATED SHEET METAL ELBOW FOR (3) FARTHEST CEILING DIFFUSERS FROM AIR HANDLER. 11. EXHAUST DUCT CONNECTION TO HOOD TO BE CONTINUOUS LIQUID TIGHT WELD. ALTERNATE GASKETED BOLT TYPE CONNECTION IS PERMISSIBLE IF ALLOWED BY LOCAL CODES. ALTERNATE CONNECTION MUST BE MADE EXACTLY AS DIRECTED BY LOCAL CODES. 12. MC TO VERIFY EXACT DIMENSIONS OF HOOD EXHAUST AND MAKE UP AIR CONNECTION WITH HOOD MFG. PRIOR TO FABRICATION OR ORDERING OF RELATED EQUIPMENT (BALANCING DAMPERS, ETC.) 13. HOOD MUST MEET U.L. 710. FLARED SHOULDER & SPIN IN COLLAR W/ INTEGRAL SCOOP. CIRCULAR CLAMP TYP. FINISHED CEILING SURFACE REDUCER OR SQUARE TO ROUND TRANSITION (IF NECESSARY) DIFFUSER/GRILLE (COORD. FRAME TYPE) NOTES: 1. PROVIDE INSULATED REGISTER BOOT/PLENUM BOX IF NECESSARY. 2. RETURN APPLICATION IS SIMILAR. ALL ELBOWS IN RETURN APPLICATION TO BE INSULATED SHEET METAL (NO FLEX ELBOWS). 2 DIFFUSER DETAIL NO SCALE 14. KITCHEN EQUIPMENT SERVED BY HOOD INTERLOCKED WITH HOOD CONTROLS. OPERATION OF KITCHEN EQUIPMENT TO BE IMPOSSIBLE WITHOUT OPERATION OF HOOD EXHAUST FAN. HOOD ACTIVATION BY TEMPERATURE SENSOR IS ACCEPTABLE ALTERNATIVE. KITCHEN HOOD FIRE SUPPRESSION SYSTEM EXHAUST FAN NOTES PROVIDE A PRE-ENGINEERED, WET CHEMICAL W/ WATER ASSIST FIRE PROTECTION SYSTEM EQUAL TO ANSUL R102 SYSTEM, DESIGNED IN COMPLIANCE WITH UL300 REQUIREMENTS. THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND REMOTE ACTUATION. THE SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 96 AND LOCAL AHJ. DISCHARGE NOZZLES WILL PROVIDE COVERAGE OF, BUT NOT LIMITED TO, THE HOOD AREA AND EXHAUST DUCT. FURNISH ELECTRIC OPERATED GAS SHUT OFF VALVE. NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. HOOD FIRE SUPPRESSION SEQUENCE OF OPERATION: UPON ACTIVATION OF THE KITCHEN HOOD FIRE SUPPRESSION SYSTEM ALL HOOD MAKE-UP AIR FANS AND KITCHEN RTU SUPPLY FANS ARE TO SHUT DOWN, HOOD EXHAUST FANS ARE TO ACTIVATE, GAS SOLENOID VALVE IS TO CLOSE, EQUIPMENT SHUNT TRIP BREAKER(S)/CONTACTOR(S) ARE TO TURN "OFF" AND A ALARM SIGNAL IS TO BE SENT TO THE BUILDING FIRE ALARM SYSTEM CONTROL PANEL. 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. U.L. LISTED HOOD EXHAUST FAN W/ FACTORY CONTROL PACKAGE & STARTER SEE SCHEDULE FOR SPECIFICATION. AIR INLET OPENING maple 10'-0" MIN. ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 KEF U.L. LISTED HOOD MAKE-UP AIR FAN W/ FACTORY CONTROL PACKAGE & STARTER SEE SCHEDULE FOR SPECIFICATION. GREASE DRAIN ON FAN & APPROVED COLLECTION RESEVOIR plumbing mechanical electrical PREFABRICATED CURB MUA SEAL OPENING AROUND DUCT WITH KAOWOOL FLANGED & GASKETED DUCT TO FAN CONNECTION AIR INTAKE W/ FILTER NOTE: DETAIL IS SCHEMATIC IN NATURE. SEE DWG'S FOR LOCATION OF FAN'S AND DUCT LAYOUT. MAKE-UP AIR DUCT EXHAUST DUCT TO FAN STEEL ANGLE ATTACHED TO STRUCTURE KITCHEN CEILING (NON-COMBUSTIBLE TILES WITHIN 18" OF HOOD) SUPPLY RISER WITH INTERNAL VOLUME DAMPERS STEEL HANGING RODS MFG. SUPPLY PLENUM PERF. PLATES ACCESS DOOR (SEE NOTES) STAINLESS STEEL CLOSURE PANEL TO CLG. STEEL HANGING ANGLE AIR FLOW PERFORATED PLATES U.L LISTED BAFFLE TYPE GREASE FILTERS EXH. CONNECTION TO HOOD (SEE NOTES) GREASE DRAIN WITH REMOVABLE CUP 3" STAND-OFF TYPE I KITCHEN EXHAUST HOOD W/ WET CHEMICAL FIRE SUPPRESSION SYSTEM. BACK WALL TO BE OF LIMITED OR NON-COMBUSTIBLE CONST. HOOD FAN AND LIGHT CONTROLS FACTORY FIRE SYSTEM CONTROL BOX TO BE MOUNTED WITHIN 75 FEET OF HOOD AND BELOW CEILING LEVEL. CABINET MAY BE INCLUDED IN CONTROL PANEL ATTACHED TO END OF HOOD. LIGHTS PRE-WIRED BY HOOD MGF (50 F.C. OF ILLUMINATION REQ'D AT ALL COOKING SURFACES) P REMOTE PULL STATION(S). COORDINATE EXACT DEVICE & PLACEMENT WITH LOCAL AHJ AND REQUIREMENTS OF 2012 NC FIRE CODE SECTION 904.11 NOTE: ADDITIONAL STRUCTURAL BRACING FOR HOOD SUPPORT PROVIDED BY OTHERS. SEE ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. 15. MC RESPONSIBLE FOR VIEWING ALL OTHER APPLICABLE KITCHEN PLANS FROM KITCHEN EQUIPMENT PROVIDER AND ARCHITECT PRIOR TO BEGINNING WORK. MC TO MAKE KNOWN ANY SIGNIFICANT DISCREPANCIES BETWEEN PLANS TO G.C., ARCHITECT OR ENGINEER. STAINLESS STEEL PANEL TO FLOOR BY OTHERS. SEE ARCH. DRAWINGS. NOTE: GAS SOLENOID VALVE TO BE PROVIDED BY FIRE SUPPRESSION CONTRACTOR AND INSTALLED BY P.C. FINAL CONNECTION BY FIRE SUP. CONTRACTOR. 16. PRIOR TO USE OR CONCEALMENT OF ANY PORTION OF THE GREASE DUCT SYSTEM A LEAKAGE TEST SHALL BE PERFORMED IN THE PRESENCE OF THE LOCAL AHJ. TEST TO BE PERFORMED AS OUTLINED IN 2012 NCMC SEC. 506.3.2.5. 17. AFTER INSTALLATION MC TO PERFORM BOTH "PERFORMANCE" AND "CAPTURE AND CONTAINMENT" TESTS IN THE PRESENCE OF THE LOCAL AHJ. SEE 2012 NCMC SEC. 507.16. 6/16/14 ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS NOTE: SEE HOOD/FAN MFG DRAWINGS FOR MORE INFO. 40" MIN. MFG. ROOF CURB W/ 1" INSUL. & NAILOR FRESH AIR INLET PREFABRICATED ROOF CURB. 18" MIN. MFG. ROOF CURB W/ NAILOR ANCHOR REGISTER TO DUCT HIGH DENSITY GASKET 2" WIDE. MIN. DISTANCE = 40" OR PARAPET HEIGHT NEMA 3R (IF WITHIN 5') DISCONNECT WHICHEVER IS GREATER. GREASE TRAP EXHAUST FAN WEATHER HOOD WITH FILTER ACCESS PANEL. ROOF TOP MOUNTED AIR HANDLING UNIT. UP-BLAST KITCHEN EXHAUST FAN Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 M-4 1 KITCEN HOOD DETAIL (TYPE 1, WALL) NO SCALE MECHANICAL DETAILS NOTE: VERIFY WRAPPER HEIGHTS W/ ARCHITECT & CEILING HEIGHTS. 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-1 HOOD DRAWINGS 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-2 HOOD DRAWINGS 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-3 HOOD DRAWINGS 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-4 HOOD DRAWINGS NOTE: PROVIDE WINDBANDS AS NECESSARY ON FANS TO ENSURE THAT EXHAUST TERMINATION IS AT LEAST 36" ABOVE AREA OUTSIDE AIR INTAKES. 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-5 HOOD DRAWINGS 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-6 HOOD DRAWINGS 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-7 HOOD DRAWINGS 6/16/14 maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical NOTE: SEE ADDITIONAL HOOD DRAWINGS & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE: HOOD & FAN DESIGN IS BY OTHERS. HOOD & FAN INFORMATION SUPPLIED BY OTHERS AND PRESENTED ON THIS DRAWING HAS ONLY BEEN REVIEWED TO THE EXTENT OF IT'S ACCEPTABILITY GIVEN THE REQUIREMENTS OF THE OVERALL MECHANICAL SYSTEM. MASTER DRAWING Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 HD-8 HOOD DRAWINGS GENERAL ELECTRICAL NOTES 9. SPLICING CONNECTORS, LUGS, ETC SHALL BE IDENTIFIED FOR USE WITH THE MATERIAL (CU/AL) OF THE CONDUCTOR AND SHALL BE PROPERLY INSTALLED. 10. RECEPTACLES IN COMMERCIAL AREAS SHALL BE 20 AMP COMMERCIAL SPECIFICATION GRADE EQUAL TO HUBBELL SERIES. GROUND FAULT RECEPTACLES SHALL BE EQUAL TO COOPER VGF SERIES. A LITHONIA 2SP8 G 3 32W T8 B 6. DO NO SCALE DRAWINGS FOR MEASUREMENT. 7. INFORMATION GIVEN IN SCHEDULES INCLUDES BOTH DESCRIPTION OF PRODUCT AND MANUFACTURER'S MODEL #. IF CONFLICT IS PRESENT BETWEEN DESCRIPTION AND MODEL #, EQUIPMENT DESCRIPTION SHALL TAKE PRECEDENT. IN CASE OF CONFLICT BETWEEN THE PLANS AND NOTES/SPECIFICATIONS OR CONFLICT BETWEEN INFORMATION PRESENTED ON THE PLANS OR IN THE NOTES/SPECIFICATIONS, THEN THE MOST RESTRICTIVE SHALL TAKE PRECEDENT. 8. 9. BEFORE BID EC IS RESPONSIBLE FOR CLARIFYING W/ G.C. ANY CONFUSION IN REGARDS TO RESPONSIBILITY OF WORK TO BE PERFORMED OR MATERIALS TO BE PROVIDED. THE SUBMITTAL OF THE BID BY THE CONTRACTOR WILL BE HELD AS PROOF THAT THE CONTRACTOR UNDERSTANDS THOROUGHLY AND COMPLETELY THE SCOPE OF THE WORK INVOLVED, AND HAS INCLUDED ON THE BID ALL THE NECESSARY ITEMS TO CARRY OUT THIS SECTION OF WORK. AS SOON AS POSSIBLE (AND NOT MORE THAN 30 DAYS) AFTER CONTRACT IS SIGNED, THE EC SHALL PROVIDE SUBMITTALS OF EQUIPMENT HE/SHE INTENDS TO PURCHASE FOR REVIEW AND COMMENT BY THE ENGINEER. ENGINEER IS TO APPROVE SUBMITTALS BEFORE EQUIPMENT IS ORDERED. 10. ALL EXISTING EQUIPMENT AND SYSTEMS ARE ASSUMED BY ENGINEER TO BE IN GOOD WORKING ORDER. BEFORE BEGINNING WORK E.C. IS TO ENSURE ANY EQUIPMENT & SYSTEMS TO REMAIN ARE PROPERLY FUNCTIONING. NOTIFY G.C. IMMEDIATELY IF PROBLEMS ARE DISCOVERED. 11. ALL QUESTIONS MUST BE SUBMITTED IN RFI FORMAT TO THE ARCHITECT AND MUST BE ADDRESSED BY THE APPROPRIATE DESIGNER OF RECORD PRIOR TO BECOMING A PROPOSED CHANGE ORDER. 12. E.C. IS TO REVIEW COMPLETE DRAWING SET. E.C. IS RESPONSIBLE FOR WORK EXPLICITLY SHOWN AND WORK IMPLIED. UNLESS OTHERWISE NOTED FINAL ELECTRICAL CONNECTION TO ALL EQUIPMENT, FURNITURE (I.E. CUBICLES, WORKSTATIONS, ETC) IS THE RESPONSIBILITY OF THE E.C.. 11. 12. 2. 3. ALL ROOF WORK INCLUDING PENETRATIONS, OPENINGS, FLASHING, CURB INSTALLS, ETC ARE TO BE PERFORMED BY ROOFING CONTRACTOR. E.C. RESPONSIBLE FOR PROVIDING ANY ROOF CURBS, EQUIPMENT RAILS, VENTS, ETC AND COMMUNICATING ALL REQ'S WITH G.C. & ROOFING CONTRACTOR. ALL LOW VOLTAGE WIRING RELATED TO MECHANICAL EQUIPMENT AND SYSTEMS IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR (ANY LOW VOLTAGE FIRE ALARM WIRING TO BE BY E.C.). ALL HIGH VOLTAGE CONNECTIONS TO MECHANICAL EQUIPMENT, TO BE PROVIDED AND INSTALLED BY E.C. (SEE EQUIPMENT SCHEDULE FOR DISCONNECT RESPONSIBILITY). ELECTRICAL CONTRACTOR IS TO EMPLOY THE SERVICES OF THE G.C. FOR CUTTING AND PATCHING OF WALLS, FLOORS & CEILINGS RELATED TO THE INSTALLATION OF ELECTRICAL EQUIPMENT & SYSTEMS. 1. 2. 3. 4. 5. 1. 2. 3. 4. 5. 6. 8. G.C. RESPONSIBLE FOR PAINTING OF ANY EXPOSED CONDUIT, WIRE, BOXES ETC. E.C. RESPONSIBLE FOR CLEANING AND PREPARING ITEMS FOR PAINT, COORDINATE W/ G.C. E.C. TO COORDINATE W/ G.C. PRIOR TO BID REGARDING HIRING OF FIRE ALARM, DATA/TELE & SECURITY SUB-CONTRACTORS (IF APPLICABLE). ALL MATERIAL, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE NEW UNLESS OTHERWISE NOTED AND SHALL CONFORM TO THE STANDARDS OF THE UNDERWRITER'S LABORATORIES, INC., AND THE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. 11. 12. 2. 3. ALL MATERIALS INSTALLED IN RETURN PLENUM ARE TO BE PLENUM RATED. 13. ALL FIRE SEALANTS TO BE U.L. LISTED AND APPROVED FOR USE W/ APPROPRIATE U.L. PENETRATION DETAIL. 5. CONDUCTORS SHALL BE COPPER RATED AT NOT LESS THAN 600 VOLTS.MINIMUM SIZE SHALL BE #12 AWG UNLESS OTHERWISE NOTED ON THE DRAWINGS. ALL WIRE #8 AWG AND LARGER SHALL BE STRANDED. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID OR STRANDED, UNLESS OTHERWISE NOTED. CONDUCTOR INSULATION SHALL BE TYPE THHN UNLESS OTHERWISE NOTED. ALL EXTERIOR CABLE OR OTHER WIRE EXPOSED TO SUNLIGHT SHALL BE RATED FOR EXTERIOR USE & SUNLIGHT RESISTANT. 6. THE ELECTRICAL CONTRACTOR SHALL COORDINATE CLOSELY WITH ALL OTHER TRADES TO AVOID CONFLICT AND ENSURE OTHER TRADES PROVIDE MEASURES TO ACCOMMODATE ELECTRICAL WORK (I.E. ACCESS DOORS, SLAB/WALL/ROOF OPENINGS, ETC). E.C. TO COORDINATE ELEVATION OF WALL MOUNTED LIGHTS (INTERIOR & EXTERIOR) W/ ARCHITECT/ARCH PLANS. E.C. TO COORDINATE W/ P.C. & M.C. REGARDING POWER AND FIRE ALARM CONNECTIONS TO MECHANICAL AND PLUMBING EQUIPMENT. E.C. TO VERIFY ALL REQUIREMENTS AND COORDINATE EXACT LOCATION OF INCOMING ELECTRICAL SERVICE WITH LOCAL POWER COMPANY PRIOR TO PROJECT START-UP. NOTIFY ENGINEER OF ANY CHANGES AS MAY BE REQUIRED. E.C. TO VERIFY DEVICE PLATE COLOR AND MATERIAL WITH ARCHITECT PRIOR TO PURCHASE. ALL WIRING SHALL BE INSTALLED IN GALVANIZED RIGID CONDUIT, INTERMEDIATE METAL CONDUIT, OR EMT, EXCEPT AS ALLOWED BELOW. EMT SHALL NOT BE USED IN OR UNDER CONCRETE SLABS, OR IN MASONRY WALLS. USE SCHEDULE 40 PVC OUTDOORS WHERE NOT SUBJECT TO PHYSICAL DAMAGE OR BELOW FLOOR SLAB. MINIMUM CONDUIT SIZE TO BE 1/2". TYPE MC AND AC CABLE MAY BE USED WHERE PERMISSIBLE BY NEC. FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTIONS TO VIBRATING EQUIPMENT AND LUMINAIRES, BUT SHALL NOT EXCEED 6' IN LENGTH. GEB10RS 96 LAY-IN 2x4 3-LAMP ACRYLIC LENSED LAY-IN RECESSED TROFFER LAY-IN 2x2 3-LAMP ACRYLIC LENSED LAY-IN RECESSED TROFFER 1 51 GEB10RS C LITHONIA LF6N 1 26W TRT MVOLT 1 ELECTRONIC D LITEFORMS CF8P26TEB 1 26W TRT 120 - - 26W RECESSED 6" RECESSED CAN/DOWNLIGHT. CLEAR LENS PENDANT 8" DIRECT PENDANT MOUNT CYLINDER. W/ 26W FLUORESCENT LAMP. DIMMABLE. E BARN LIGHT ELEC. BLE-C-VSBA-PC 1 - 120 - - 22W PENDANT F BARN LIGHT ELEC. BLE-G-AUS-PC 1 - 120 - - 22W WALL TEGAN TG-MPS-IT-AL-MP 1 120 12W LED - - 12W WALL H LIGHTOLIER 1135/1101FTU 1 26W TRT 120 1 - 26W RECESSED J LUMIERE CAMBRIA 922 1 6W LED 120 1 - 6W WALL CAMBRIA 922 WALL MOUNTED SIGN LIGHT. K KASON 1810 EZ 2 32W T8 120 1 COLD TEMP 64 SURFACE J L LITHONIA LITHONIA LITHONIA LITHONIA LF6N 1 LQC 1 LQC 1 ELM2 2 26W TRT MVOLT LED 120, 277 LED 120, 277 - 120, 277 - 5.4 W 1 ELECTRONIC - 26W - 1.2 - 1.2 - 1.2 RECESSED SINGLE POLE SWITCH, 20A, 120/277 VOLT, 48" A.F.F. TO CENTER. "3" INDICATES 3-WAY SWITCH. "4" INDICATES 4-WAY SWITCH. "D" INDICATES DIMMER SWITCH OF TYPE TO SUIT LOAD. "M" INDICATES 120V, 20A MOTOR RATED TOGGLE SWITCH. "DP" INDICATES DOUBLE POLE INDICATES FLUORESCENT FIXTURES DUAL SWITCHED, INBOARD/OUTBOARD SWITCHED SEPARATELY. DUPLEX RECEPTACLE, 20 AMP (15 AMP RESIDENTIAL, UON), 120 VOLT, 18" A.F.F. TO CENTER. "GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE. "WP" INDICATES WEATHERPROOF. "EWC" INDICATES RECEPTACLE INSIDE ENCLOSURE OF ELECTRIC WATER COOLER PROVIDE GFI BREAKER FOR CIRCUIT. "ASW" INDICATES ABOVE SHOW WINDOW, PER NEC SHOW WINDOW REQ'S. QUADRUPLEX RECEPTACLE, AS ABOVE, 18" A.F.F. DUPLEX RECEPTACLE, AS ABOVE, SPLIT WIRED, TOP HALF SWITCHED, 18" A.F.F. 6" RECESSED CAN/DOWNLIGHT. NO LENS CEILING EXIT LIGHT W/ BATTERY BACK-UP. RED ILLUMINATED EXIT SIGN. ALUM. FACE. HOUSING COLOR BY ARCH. WALL EXIT LIGHT W/ BATTERY BACK-UP. RED ILLUMINATED EXIT SIGN. ALUM. FACE. HOUSING COLOR BY ARCH. DUPLEX RECEPTACLE, AS ABOVE, MOUNTED 6" ABOVE COUNTER TOP OR 4" ABOVE BACKSPLASH, AS APPROPRIATE, OR AT HEIGHT INDICATED. DUPLEX RECEPTACLE, AS ABOVE, MOUNTED 6" ABOVE COUNTER TOP OR 4" ABOVE BACKSPLASH, AS APPROPRIATE, OR AT HEIGHT INDICATED, WITH GFI PROTECTION. RECESSED FLUSH FLOOR DUPLEX RECEPTACLE WITH BRASS COVERPLATE. COORDINATE EXACT FINISH WITH ARCHITECT AND OWNER. GEN. PURPOSE EMERGENCY LIGHT. (2) ADJ. HEADS. BATTERY BACK-UP. SEE PLAN NOTES: 1. UNLESS OTHERWISE NOTED COLOR & FINISH OF FIXTURE HOUSING, BAFFLE, OR SIMILAR EXPOSED ELEMENTS TO BE BY ARCHITECT. 2. WHERE MASTER SLAVE WIRING CONFIGURATIONS IS INDICATED THE CONTRACTOR SHALL VERIFY THE QUANTITY AND TYPE OF BALLASTS REQUIRED TO PERMIT BI-LEVEL SWITCHING. WHERE BI-LEVEL LIGHTING IS INDICATED INBOARD AND OUTBOARD LAMPS SHALL BE SWITCHED SEPARATELY. 3. EXIT AND EMERGENCY LIGHTING FIXTURES SHALL BE CIRCUITED TO AN UNSWITCHED LEG OF A NORMALLY ON LOCAL LIGHTING CIRCUIT (UNLESS NOTED OTHERWISE),INCLUDE 90 MINUTE BATTERY BACKUP & TESTING MEANS. 4. PROVIDE DISCONNECT FOR LUMINAIRES WITH LINEAR FLUORESCENT LAMPS AND/OR SERVICEABLE BALLASTS PER NEC 410.130(G). 5. FIXTURES WITH A STANDARD FACTORY INSTALLED EMERGENCY OPTION SHOULD USE THAT WHERE "EMC" IS SHOWN. 6. ALL LAMPS OF A SINGLE FIXTURE TYPE INSTALLED IN EACH AREA/ROOM/SPACE ARE TO BE OF SAME TEMPERATURE/COLOR. 208V RECEPTACLE, SEE PLANS FOR NEMA CONFIGURATION. TELEPHONE/DATA OUTLET, 18" A.F.F. TO CENTER OR ALIGN MOUNTING HEIGHT WITH ADJACENT DEVICE, UNLESS OTHERWISE NOTED. COORDINATE EXACT DEVICE TYPE AND REQUIRED FACEPLATE W/ OWNER/TENANT. 30/3/FPN LIGHTING SYSTEMS NCECC SECTION 505 & 506 INTERIOR LIGHTING POWER DENSITY CALCULATION PER TABLE 505.5.2. SEE LIGHTING FIXTURE SCHEDULE FOR FIXTURE INFORMATION. PROVIDE A PULLWIRE IN ALL EMPTY CONDUITS. INTERIOR WATTAGE SPECIFIED VS. ALLOWED TRADABLE EXTERIOR WATTAGE SPECIFIED VS. ALLOWED NONTRADABLE EXTERIOR WATTAGE SPECIFIED VS. ALLOWED EF NAME: ZACK L. TOMLIN, PE TITLE: ELECTRICAL ENGINEER TRACK LIGHTING FIXTURE, SEE FIXTURE SCHEDULE FOR DETAILS. SURFACE MOUNTED FLUORESCENT STRIP, SEE FIXTURE SCHEDULE FOR DETAILS. WALL MOUNTED LIGHTING FIXTURE, SEE FIXTURE SCHEDULE FOR DETAILS. ADDITIONAL PRESCRIPTIVE COMPLIANCE 506.2.4 HIGHER EFFICIENCY SERVICE WATER HEATING 506.2.5 ON-SITE SUPPLY OF RENEWABLE ENERGY 506.2.6 AUTOMATIC DAYLIGHTING CONTROL SYSTEMS X SURFACE, RECESSED OR GROUND MOUNTED LIGHTING FIXTURE, SEE FIXTURE SCHEDULE FOR DETAILS. M PENETRATIONS OF NON-RATED WALLS, PARTITIONS AND FLOOR OF COMBUSTIBLE CONSTRUCTION SHALL BE FIRESTOPPED WITH MATERIALS EQUIVALENT TO TWO INCHES OF WOOD. FIRESTOPPING SHALL COMPLY WITH ASTM E-814. PENETRATIONS OF ALL EXTERIOR WALLS, FLOORS AND CEILINGS SHALL BE SEALED IN AN AIR TIGHT MANNER AND IN ACCORDANCE W/ 2012 NCECC APPENDIX 2 DETAILS. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELECTRICAL EQUIPMENT FROM FOREIGN MATERIAL DURING CONSTRUCTION (PAINT, SPACKLE, ETC.). UPON COMPLETION OF WORK THE ELECTRICAL CONTRACTOR SHALL CLEAN, WASH, ETC ALL ITEMS AND EQUIPMENT WITHIN HIS SCOPE OF WORK AND LEAVE ALL ITEMS BRIGHT AND CLEAN. IN REQUIRED FIRE RATED WALLS AND PARTITIONS, OPENINGS FOR INSTALLATION OF BOXES THAT ARE GREATER THAN 16 SQUARE INCHES SHALL BE PROTECTED AS REQUIRED BY U.L. UNLESS OTHERWISE INDICATED THE ELECTRICAL CONTRACTOR AT HIS/HER DISCRETION MAY COMBINE MULTIPLE CIRCUITS INTO A SINGLE CONDUIT AND DE-RATE WIRE. COMBINING AND DE-RATING IS TO BE DONE IN STRICT ACCORDANCE W/ NEC. 14. DEVICES INCLUDING GFCI PROTECTION MUST HAVE THEIR TESTING MEANS READILY ACCESSIBLE. PROVIDE REMOTE TESTING MEANS OR GFCI BREAKER FOR GFCI RECEPTACLES AND SIMILAR DEVICES WHICH ARE NOT READILY ACCESSIBLE (I.E. BEHIND EQUIPMENT, AT CEILING, ETC). (NEC 210.8). COORDINATE WITH THE CABLE TV AND TELEPHONE UTILITIES FOR SERVICE ENTRANCE AND CABLING REQUIREMENTS PRIOR TO ANY PURCHASING. INSTALLATION MUST COMPLY WITH THEIR RESPECTIVE REGULATIONS AND REQUIREMENTS. 15. ALL EXIT & EMERGENCY LIGHTS ARE TO BE CIRCUITED TO UN-SWITCHED LEG OF LOCAL NORMALLY ON LIGHTING CIRCUIT. 16. RECEPTACLE, LIGHT SWITCHES AND OTHER CONTROL DEVICES ARE TO BE INSTALLED IN ACCORDANCE W/ ANSI A117.1 AND ADA REQ'S CONCERNING HEIGHT AND ACCESSIBILITY. FHA REQ'S TO BE FOLLOWED FOR MULTI-FAMILY AND RESIDENTIAL PROJECTS. 17. E.C. IS TO CONFIRM EXACT ELECTRICAL NAMEPLATE DATA OF ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT INCLUDING, BUT NOT LIMITED TO, MCA, MOCP, VOLTAGE & PHASE BEFORE BEGINNING WORK. FAN, PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. PROVIDE DISCONNECTING MEANS AS REQUIRED. RECESSED MOUNTED 2x4 FLUORESCENT TROFFER, SEE FIXTURE SCHEDULE FOR DETAILS. SIGNED: EXIST. VS. EXIST. NA VS. NA NOT APPLICABLE (RENOVATION PROJECT) 506.2.1 MORE EFFICIENT MECHANICAL EQUIPMENT 506.2.2 REDUCED LIGHTING POWER DENSITY 506.2.3 ENERGY RECOVERY VENTILATION SYSTEM 6/16/14 480Y/277V PANEL, SURFACE OR RECESS MOUNTED, SEE SCHEDULE FOR DETAILS. 3080 VS. 3451 EXTERIOR LIGHTING POWER DENSITY CALCULATION PER TABLE 505.6.2. SEE LIGHTING FIXTURE SCHEDULE FOR FIXTURE INFORMATION. HEAVY DUTY FUSIBLE/NON-FUSIBLE DISCONNECT SWITCH, NUMBERS INDICATE FRAME SIZE, NUMBER OF POLES AND FUSING. PROVIDE NEMA 1 ENCLOSURE INSIDE. PROVIDE NEMA 3 ENCLOSURE FOR ALL SWITCHES LOCATED OUTSIDE. "FPN" INDICATES FUSE PER EQUIPMENT NAMEPLATE "NF" INDICATES NON-FUSED. "MS" INDICATES MOTOR STARTER OF TYPE TO SUIT LOAD. 208Y/120V PANEL, SURFACE OR RECESS MOUNTED, SEE SCHEDULE FOR DETAILS. DESIGNER STATEMENT: SUPPORT ALL CONDUIT AND EQUIPMENT IN ACCORDANCE W/ NEC. ANY SUSPENDED MATERIALS SHALL BE DIRECTLY SUPPORTED BY THE BUILDING STRUCTURE. JUNCTION BOX FLOOR MOUNTED. JUNCTION BOX WALL MOUNTED AT HEIGHT INDICATED ON DRAWINGS. 4' 2-LAMP VAPOR PROOF GASKETED SURFACE MOUNT FLUORESCENT COOLER FIXTURE. TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS BUILDING COMPLIES WITH THE LIGHTING SYSTEMS REQUIREMENTS OF THE NORTH CAROLINA ENERGY CONSERVATION CODE, SECTION 505 & 506 AND ANY LOCAL AMENDMENTS THEREOF. SEAL ALL PENETRATIONS OF SMOKE PARTITIONS OR FIRE RATED WALLS, CEILING, FLOORS IN ACCORDANCE W/ APPROPRIATE U.L. PENETRATION DETAIL AND NC BUILDING CODE. INDICATES HOT LEG OF CIRCUIT TO BE CARRIED OVER TO NEXT DEVICE. SEE PLANS FOR CONTROL SCHEME. SINGLE RECEPTACLE, 20 AMP, 120 VOLT, 18" A.F.F. TO CENTER. LIGHTING POWER DENSITY CALCULATION COMPLIANCE ALL PENETRATIONS THROUGH EXTERIOR WALLS & ROOF SHALL BE FLASHED & COUNTER-FLASHED IN A WATERPROOF MANNER. ARROWHEAD INDICATES HOMERUN TO PANEL NOTED. WALL MOUNTED MONO POINT LIGHT FIXTURE.LEDLAMP. W/ CLARO SPOTLIGHT. A COMPLETE GROUNDING SYSTEM SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF THE NEC, AND AS SHOWN ON THE DRAWINGS. PROVIDE A TYPED DIRECTORY IN ALL PANELBOARDS CLEARLY DESCRIBING THE LOCATION OF AND TYPE OF LOAD BEING SERVED FOR ALL CIRCUITS. PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL PANELBOARDS AND DISCONNECT SWITCHES, WHITE LETTERS ON BLACK BACKGROUND. CIRCUIT CONDUCTORS CONCEALED IN FLOOR, WALL OR CEILING. ASTRO SHALLOW BOWL VENTED PENDANT. CORD HUNG. COORDINATE FINISH W/ OWNER. W/ PHILLIPS 22W LED BULB. ALL WEATHER GOOSENECK FARM LIGHT WALL MOUNTED FIXTURE. COORDINATE FINISH W/ OWNER. W/ PHILLIPS 22W LED BULB. 6" RECESSED CAN/DOWNLIGHT. W/ SCOOP REFLECTOR LENS. E.C. TO FOLLOW MANUFACTURER'S INSTRUCTIONS WHEN INSTALLING ELECTRICAL EQUIPMENT. ENSURE REQUIRED MAINTENANCE ACCESS AND CLEARANCES ARE MAINTAINED. IF CONFLICT EXISTS BETWEEN THESE PLANS AND MFG INSTRUCTIONS CONTACT ENGINEER. PROVIDE HANGERS & SUPPORTS APPROVED FOR USE BY NEC. 4. 1 DESCRIPTION ### 7. III. MATERIALS: 1. ALL EXTERIOR FIXTURES AND DEVICES SHALL BE RATED FOR V. EXECUTION: 10. 5. MVOLT MOUNTING IV. COORDINATION: 9. 4. 17W T8 INPUT WATTS LIGHTING SWITCHES SHALL BE 20 AMP COMMERCIAL SPECIFICATION GRADE EQUAL TO HUBBELL SERIES. REQUIRED. II. DIVISION OF WORK: 1. 3 TYPE maple ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical ELECTRIC UTILITY METER LOCATION. KITCHEN EQUIPMENT TAG. DEMO'D LIGHT FIXTURE OR SIMILAR. DEMO'D RECEPTACLE OR SIMILAR. CEILING FIRE ALARM HORN, HORN/STROBE OR STROBE. TV NOTE: DEVICE HEIGHTS ARE TO BE AS INDICATED UNLESS OTHERWISE NOTED. FIRE WALL MOUNTED TELEPHONE RECEPTACLE LIGHT SWITCH OR DIMMER TELE/DATA SWITCH FIRE ALARM PULL STATION RECEPTACLE TELEPHONE OR DATA JACK TOP OF COUNTER MAX COUNTER DEPTH = 24" FLOOR NOTE: MOUNTING LOCATIONS OF RECEPTACLES, SWITCHES AND ALL OTHER CONTROL DEVICES SHALL BE IN ACCORDANCE WITH ANSI A117.1 AND ADA REQUIREMENTS (FHA REQ'S FOR MULTI-FAMILY AND RESIDENTIAL PROJECTS) 1 TYPICAL DEVICE MOUNTING HEIGHTS CABLE TV OUTLET, 18" A.F.F. TO CENTER, UNLESS OTHERWISE NOTED. ELECTRICAL ABBREVIATIONS 18" ALIGN DEVICES WHEN MOUNTED CLOSE ON SAME WALL 36" MAX THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL LOCATION AND ARRANGEMENT OF ALL MATERIALS AND EQUIPMENT. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS BUILDING CONSTRUCTION AND ALL OTHER WORK WILL PERMIT. 2SP8 G MVOLT BALLAST DATA NO. JUNCTION BOX CEILING MOUNTED. G 5. LITHONIA VOLTS 42" ALL EQUIPMENT, MATERIALS AND INSTALLATION SHALL BE GUARANTEED TO BE FREE OF DEFECTS FOR A PERIOD OF ONE (1) YEAR AFTER FINAL ACCEPTANCE OF WORK OR IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD GUARANTEE, IF LONGER. EXISTING EQUIPMENT IS EXCLUDED FROM WARRANTY REQUIREMENT. FUSES 0 - 600 AMPS SHALL BE UL CLASS "RK-1" LOW PEAK DUAL ELEMENT TIME DELAY WITH 200,000 AMPERE INTERRUPTING RATING AS MANUFACTURED BY BUSSMANN, UNLESS NOTED OTHERWISE. TYPE 48" 4. ALL ELECTRICAL & LIGHTING EQUIPMENT SHALL BE PROVIDED COMPLETE WITH ALL ACCESSORIES, HANGERS, SUPPORTS, CONTROLS, ETC FOR A FULLY FUNCTIONING SYSTEM REGARDLESS OF PRESENCE ON PLANS. 8. NO. 80" 3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH NEC AND ALL OTHER APPLICABLE CODES. EC IS TO COORDINATE W/ G.C. IN REGARDS TO PROJECT TIMELINE, WORK HOURS, AS WELL AS ANY BONDING OR INSURANCE REQUIREMENTS. CATALOG NUMBER 46" 2. ELECTRICAL CONTRACTOR IS TO FURNISH AND PAY FOR ALL LABOR, MATERIAL, EQUIPMENT, PERMITS & FEES REQUIRED FOR THE COMPLETE INSTALLATION OF ALL SYSTEMS IN THIS SECTION OF WORK. METAL CONDUIT COUPLINGS TO BE COMPRESSION TYPE OR THREADED WHEN ACCESSIBLE TO BUILDING OCCUPANTS. METAL COUNDUIT COUPLINGS MAY BE SET-SCREW TYPE WHEN CONCEALED IN BUILDING STRUCTURE OR LOCATED MORE THAN 10' AFF. PLASTIC CONDUIT COUPLINGS TO BE SOCKET GLUED TYPE. MANUF. 46" 1. 7. LAMP DATA MARK 18" I. GENERAL REQUIREMENTS: ELECTRICAL SYMBOL LEGEND LIGHTING FIXTURE SCHEDULE DIMENSION INDICATES HEIGHT ABOVE FINISHED FLOOR AT WHICH CENTER OF DEVICE IS TO BE MOUNTED. AFF ABOVE FINISHED FLOOR. AFG ABOVE FINISHED GRADE. E.C. ELECTRICAL CONTRACTOR. FPN FUSE PER EQUIPMENT NAMEPLATE REQUIREMENTS. G.C. GENERAL CONTRACTOR. M.C. MECHANICAL CONTRACTOR. P.C. PLUMBING CONTRACTOR. WP INDICATES DEVICE TO HAVE WEATHERPROOF COVER. UON UNLESS OTHERWISE NOTED. FACP FIRE ALARM CONTROL PANEL. SMP SPRINKLER MONITORING PANEL. NL NIGHT LIGHT, LIGHT NOT SWITCHED. WP WEATHER PROOF NO SCALE Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 MOTION SENSOR LEGEND M0 WALL SWITCH DUAL TECH. (INFRARED AND ULTRASONIC) OCCUPANCY SENSOR EQUAL TO SENSOR SWITCH MODEL WSX PDT. 120/277V. TIME DELAYS 15 MINUTES FOR ON/OFF. LINE VOLTAGE. E-1 ELECTRICAL SCHEDULES DETAILS & NOTES FIRE RATING LEGEND 1-HR WALL DIMMER SWITCH TO ADDITIONAL CONTACTORS AS REQUIRED. LIGHTING CONTACTOR LIGHTING CIRCUITS FR PANEL SINGLE SWITCH SINGLE SWITCH SINGLE SWITCH SINGLE SWITCH OFF OFF OFF DIMMER SWITCH DIMMER SWITCH DIMMER SWITCH A B C E G H J CUST. LINE B-5 FRNT. COUNTER B-3 FRNT. KITCHEN B-1 BACK KITCHEN B-1 DINING 1 WALL B-11 DINING 1 B-11 DINING 2 B-9 SINGLE SWITCH DIMMER SWITCH DIMMER SWITCH DIMMER SWITCH DIMMER SWITCH SINGLE SWITCH DIMMER SWITCH PROG. SWITCH #:## CIRCUITS TO FIXTURES OFF OFF OFF LINE c OVERRIDE SWITCH GENERAL NOTES - THIS SHEET PROG. SWITCH (SEE SWITCH BANK DETAIL) 1. 2. NOTE: 1. E.C. TO COORDINATE # OF CIRCUITS CONTROLLED AND NATURE OF LOADS W/ CONTACTOR MFG. PROVIDE MULTIPLE CONTACTORS AS REQUIRED. 2. OVERRIDE SWITCH TO BE LOCATED AT LIGHTING CONTACTORS & CLEARLY LABELED. 3. LOCATE ALL CONTACTORS NEXT TO PANEL. CLEARLY LABEL. 3 K L N P Q R T V ENTRY CANS B-11 DINING 4 B-5 DINING 3 PENS B-7 DINING 4 WALL B-7 BACK HALL B-7 FRONT DINING PENS B-11 SIGNS B-13 MONOPOINTS B-5 LOAD 3. 4. 5. 6. LIGHTING CONTACTOR DETAIL TAGGED NOTES - THIS SHEET ITEMS SHOWN IN FAINT ARE EXISTING TO REMAIN. NEW OR RELOCATED ITEMS ARE SHOWN IN BOLD. SEE LEGEND. E.C. TO VERIFY EXISTING CONDITIONS BEFORE BEGINNING WORK. E.C. TO TEST OPERATION & BATTERY LIFE OF ALL EXISTING EXIT AND EMERGENCY LIGHTS. CONDUITS ENTERING WALK-IN FREEZER AND/OR COOLER ARE TO BE SEALED IN ACCORDANCE W/ NEC 300.7. ENSURE THAT ALL EXIT AND EMERGENCY LIGHTS ARE CONNECTED TO LOCAL NORMALLY ON LIGHTING CIRCUIT AND ARE WIRED UPSTREAM OF ALL SWITCHES, CONTACTORS, AND SIMILAR. COORDINATE ELEVATION OF WALL MOUNTED & PENDANT/SUSPENDED LIGHTS W/ ARCHITECT. 1. COORDINATE EXACT SWITCH TYPE W/ OWNER AND FIXTURES & BALLAST(S) BEING CONTROLLED. 2. LABEL SWITCHES W/ DESIGNATION SHOWN (I.E. "A", "AN", "W", ETC) & CIRCUIT #. FIXTURE "J" INDICATES DECORATIVE SIGN LIGHT CIRCUITED & SWITCHED AS SHOWN. COORDINATE EXACT LOCATION & DETAILS W/ ARCH. 3. PROVIDE PLACARD AT EACH SWITCH INDICATING AREA CONTROLLED. 4. DIMMER SWITCH TO INCLUDE ON-OFF SWITCH AT BOTTOM TO ALLOW FOR ONE-TIME ADJUSTMENT OF 3 EXISTING EXTERIOR EMERGENCY LIGHT. 5. HIGHEST POSITION OF HIGHEST SWITCH TO BE NO GREATER THAN 48" AFF (ANSI A117.1) 4 WIRE LIGHT FIXTURE AS NIGHT LIGHT. 6. PROGRAMMABLE TIME SWITCH TO BE WIRED TO LIGHTING CONTACTOR. SEE DETAIL. SWITCH TO BE 7-DAY 5 VERIFY LOCATION OF SWITCH BANK W/ OWNER/ARCHITECT. INTEGRAL HOOD LTS BY HOOD MFG. 2 6 NO SCALE SWITCH BANK NOTES: BATHROOM EXHAUST FAN TO BE ON WHEN LIGHTS IN EITHER MEN'S OR WOMEN'S ARE ON. COORDINATE W/ M.C.. PROVIDE CONTACTORS AS NECESSARY. 1 LIGHT LEVELS. PROGRAMMABLE W/ HOLIDAY SCHEDULING & DAYLIGHT SAVINGS TIME ADJUSTMENT. SWITCH TO INCLUDE TIME OVERRIDE FEATURE (2-HOUR MAXIMUM). SWITCH BANK DETAIL 2 STORAGE NO SCALE 6/16/14 B-9 N B-7 D B L AREA CNTRLD RESTARAUNT H H H E E E D D R E maple Q P MEN E ENGINEERING, pllc C B-5 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 L plumbing mechanical electrical F 1 HALL H D D D D D D D D D E L C H DINING AREA 4 WOMEN DINING AREA 3 DINING AREA 2 J T F J 2 B-13 D D D D D D D D D E A NL D 4 E B-35 E TO GO ORDERS A E V CEIL. CUSTOMER QUEUE E E E E CEIL. CEIL. H G B-11 G B NL BACK HALL B C C C C C C C C C D C 4 B-35 D D E CAN WASH OFFICE 3 EMG C H C FRONT KITCHEN B-1 C E B-3 3 CEIL. A K 6 A A SWITCH BANK A A C A A E D D D C 5 M0 E CATERING STORAGE DINING AREA 1 T PREP KITCHEN/ DRY STORAGE J B-13 6 2 K D D J D B-13 A A A A A A G A H H H Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 E-2 1 ELEC. LIGHTING PLAN SCALE: 1/4" = 1'-0" ELECTRICAL LIGHTING PLAN FIRE RATING LEGEND 1-HR WALL MUA EXH FAN(S) FAN(S) M DISCONNECT M SWITCH & CIRCUIT FOR HOOD LIGHTS TO RTU INTERLOCK, FIRE ALARM OR OTHER AUX. INPUT/OUPUTS. HOOD CONTROLS LIGHT CIRCUIT FAN CIRCUIT FAN CIRCUIT NOTES: 1. HOOD(S) CONTROL PANELS BY OTHERS. CONFIRM INSTALLATION W/ HOOD MFG. SEE HOOD DRAWINGS FOR ADDITIONAL INFO. 2. INSIDE FAN CIRCUIT DISCONNECTS MAY BE OMITTED IF BREAKER PANEL IS WITHIN LINE OF SIGHT. 3. E.C. TO COORDINATE EXACT # OF FANS. 4. SEE PANEL SCHEDULES & HOOD DRAWINGS FOR CIRCUIT INFORMATION. PHASE KW AMPS HOOD WIRING DETAIL 4 NO SCALE CEILING PLUG VOLT DIR. CONN. EQUIPMENT SCHEDULE 1-1/2" CONDUIT SLEEVE PULLSTRING CONDUIT (CONFIRM SIZE W/ OWNER) GENERAL NOTES - THIS SHEET ITEM # QTY. DESCRIPTION 1 1 U/C MOBILE HEATED PAN CABINET 120 1 - 14.1 - X RECEPTACLE @ 18" AFF. 2.1 1 COUNTER TOP GRIDDLE 120 1 - 15.0 - X RECEPTACLE @ 30" AFF. 3 1 REFRIGERATED EQUIPMENT STAND 120 1 - 10.0 - X RECEPTACLE @ 18" AFF. 7 1 REFRIGERATED SANDWICH UNIT 120 1 - 12.0 - X RECEPTACLE @ 18" AFF. 8 1 REFRIGERATED SANDWICH UNIT 120 1 - 7.2 - X RECEPTACLE @ 18" AFF. 9 1 REFRIGERATED BACKBAR CABINET 120 1 - 5.0 - X RECEPTACLE @ 18" AFF. 13 1 HOT FOOD COUNTER 120 1 - 11.7 - X RECEPTACLE @ 18" AFF. FLOOR TO DECK WALL ELECTRICAL NOTES 1. E.C. TO VERIFY EXISTING CONDITIONS BEFORE BEGINNING WORK. E.C. TO COORDINATE EXACT LOCATION AND INSTALLATION OF ALL KITCHEN EQUIPMENT W/ OWNER. CONDUITS ENTERING WALK-IN FREEZER AND/OR COOLER ARE TO BE SEALED IN ACCORDANCE W/ NEC 300.7. 2. 3. 16 2 CONVECTION OVEN 208 3 - 31.0 X - JUNCTION BOX @ 48" AFF. 17 1 KETTLE ON STAND 208 3 - 27.2 X - JUNCTION BOX @ 24" AFF. 20 1 ICE MAKER W/ BIN 120 1 - 18.3 X - JUNCTION BOX @ 64" AFF. TAGGED NOTES - THIS SHEET FLOOR PROVIDE POWER FOR SIGN CIRCUIT. COORDINATE EXACT LOCATION, SIGN REQUIREMENTS AND SCOPE OF WORK W/ OWNER. 1 21 1 ICE DISPENSER 120 1 - 2.5 - X RECEPTACLE @ 50" AFF. 22 1 WALK-IN COOLER 120 1 - 4.0 X - COOLER LIGHTS 22-CC 1 WALK-IN COOLER COMPRESSOR 208 3 - 7.2 X - - 22-CE 1 WALK-IN COOLER EVAPORATOR 120 1 - 1.8 X - - 26 2 BAG-IN-BOX SYSTEM 120 1 - 3.0 - X - 34 1 AIR CURTAIN 120 1 - 9.0 X - - 36 1 DISHWASER 120 1 - 9.4 X - JUNCTION BOX @ 72" AFF. 43 1 WARMING CABINET 120 1 - 10.0 - X RECEPTACLE @ 72" AFF. DATA/TELE/CATV OUTLET BOX. COORDINATE SIZE W/ ELECTRICAL PLAN. COORDINATE FACE PLATE W/ OWNER. 4 RTU TO INCLUDE FACTORY MOUNTED DISCONNECT & FACTORY POWERED GFI SERVICE RECEPTACLE. COORDINATE W/ M.C.. USE EXISTING CONDUIT TO TRANSFORMER. E.C. TO CONFIRM. WIRED VIA LTS & CONTACTOR. SEE LIGHTING PLAN. 5 WIRE VIA HOOD CONTROLS. 6 EVAPORATOR UNIT WIRED VIA CONDENSING UNIT. 2 3 NOTE: E.C. TO VERIFY EXACT TYPE, QTY, LOCATION OF EQUIPMENT ELECTRICAL CONNECTIONS BEFORE BEGINNING WORK. E.C. TO ALSO VERIFY ACTUAL EQUIPMENT NAMEPLATE VALUES. FINAL CONNECTION TO EQUIPMENT BY E.C.. NOTE: FOR INTERIOR WALLS WITHOUT INSULATION. E.C. MAY OMIT CONDUIT & OUTLET BOX. PROVIDE PULL STRING & PLASTER RING. 3 DATA/TELE/CATV OUTLET NO SCALE 6/16/14 MEN ASW ASW STORAGE B-39 B-17 B-39 B-17 maple ON ROOF 4 B-25 WP,M ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 EF-1 B-25 plumbing mechanical electrical HALL B-39 ASW ELECTRICAL SERVICE. (SEE RISER) WOMEN 3 M DINING AREA 4 B-25 DINING AREA 3 DINING AREA 2 B-25 B-23 B-23 RTU-2 M B-40 +84",RP-1 B-10 B-40 B-40 1 13 J A-20 34 B-2 B-38 B-23 B 21 7 9 OFFICE B-38 B-4 B-6 B-33 +50" B-8 KSF-3 B-12 B-18 +72" 5 5 43 A-8,10,12 WP,30/3/FPN 3 H-7 22 36 CU-1 A-19,21,23 WP,30/3/FPN CATERING STORAGE 8 A-8,10,12 WP,30/3/FPN B-24 +30" J B-30 ON ROOF KEF-2 2.1 H-8 M +72" 6 B-41 1 FRONT KITCHEN 20 +64" M WP,M B-31 B-27 26 A EVAP ASW A-1,3,5 CUSTOMER QUEUE B-19 CAN WASH B-39 2 RTU-1 A-7,9,11 TO GO ORDERS BACK HALL 2 B-28 +24" H-2,4,6 B-28 PREP KITCHEN/ DRY STORAGE 17 J +48" J B-17 DINING AREA 1 +48" H-1,3,5 H-9,11,13 16 16 ON ROOF KEF-1 5 A-2 H WP,M B-17 RTU-3 B-15 2 A-4 A-13,15,17 B-15 26 B-10 Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 E-3 2 METALLIC PIPE (GYPSUM WALL) DETAIL NO SCALE 1 ELEC. POWER PLAN SCALE: 1/4" = 1'-0" ELECTRICAL POWER PLAN VOLTAGE: 208Y/120V BACK WALL OF REAR KITCHEN 3 PHASE, 4 WIRE PANEL: H FLUSH MOUNTED AMPS: 100-MLO NOTES -DESCRIPTION- POLE BRK SIZE CKT # 1 CONVECTION OVEN 3 8 40 A 3.7 B C GFI REF. EQUIP. STAND 1 20 12 3.7 3.2 3 8 40 1 - - 3.7 0 11 13 3.3 3.7 3.7 15 0 NOTES TOTAL CONNECTED kVA: 3 KETTLE COUNTERTOP GRIDDLE GFI POLE BRK SIZE CKT # C LTS: KITCHEN/OFFICE 1 12 20 1 C LTS:FRNT KITCHEN/BCK HALL 1 12 20 3 C LTS:DINING4/CUST. LINE 1 12 20 5 C LTS:B-RMS/DINING 4-3 1 12 20 7 9 NOTES -DESCRIPTION- 20 12 1 10 - - 1 SPACE C LTS: DINING AREA 4-3 1 12 20 - 1 SPACE C LTS: DINING 1/FRNT 1 12 20 11 - - 1 SPACE C DECORATIVE SIGNS 16 - - 1 SPACE 10.7 DEMAND kVA: 24.5 PANEL RMS SYM. AMPS: SEE RISER DEMAND AMPS: 68.0 PANEL SHALL BE EQUAL TO SQUARE D QO. GFI - PROVIDE GFCI BREAKER FOR CIRCUIT. GFCI RECEPTACLES MAY BE USED IN LIEU OF GFCI BREAKERS SO LONG AS THE DEVICE(S) CONFORM TO NEC CODE REQUIREMENTS FOR GFCI PROTECTION & ACCESSIBILITY. PANEL "H" LOAD SUMMARY LOAD TYPE kVA CONN. LOADS ON 100 AMP BREAKER @ PANEL A DEM. FACT. kVA DEM. 1 12 20 REC: BACK WORKTABLE 1 12 20 15 REC: DINING AREA 1 12 20 17 1 12 20 19 GFI RECIRC. PUMP - 20 1 12 20 23 REC: BATHROOMS 1 12 20 25 1 12 20 27 1 - 20 29 1 12 20 31 REC: FRONT COUNTER 1 12 20 33 NIGHT LIGHTS 1 12 20 35 SPARE 1 - 20 37 REC: SHOW WINDOW 1 12 20 39 1 12 20 41 GFI MOBILE HEATED PAN SPARE GFI HOT FOOD COUNTER TC SIGN KITCHEN EQUIPMENT # PIECES COOKING EQUIPMENT: 5 35.0 0.70 0.8 24.5 TOTAL AMPS @ 35.0 AIR CURTAIN 4 30 10 1 ICE MAKER W/ BIN 6 20 12 1 ICE DISPENSER GFI 5 8 20 12 1 REFERIGERATER BACK BAR GFI 7 10 20 12 1 BAG-IN-BOX GFI 12 20 12 1 SANDWICH UNIT GFI 11 14 20 - 1 SPARE GFI 13 16 20 - 1 SPARE 18 20 12 1 20 1.4 1.2 0 0 0.6 0.4 0.8 0 1.7 0.4 0 1.4 1.1 0 0.4 0 0.2 0 0.4 0.6 0.6 1.2 6.7 8.6 TOTAL CONNECTED kVA: TOTALS 1 0 0 0 12 0 0.2 1 20 0.3 0.6 SPARE 2 0.4 0.4 REC:CATERING/BACK HALL POLE 0.6 0.5 21 CKT# 2.1 0 3 PHASE NOTES NOTES -DESCRIPTION- POLE WIRE SIZE BRK SIZE CKT # 1 PANEL: A FLUSH MOUNTED RTU-1 3 RTU-2 3 RTU-3 3 60 4 8 2.8 0.8 4.7 SPARE 20 - 1 SPARE 24 20 12 1 26 - - 1 SPACE SPACE 1 - - 25 28 20 12 1 REC: WORKTABLE SPACE 1 - - 27 30 20 12 1 DISHWASHER SPACE 1 - - 29 32 - - 1 SPACE SPACE 1 - - 31 34 - - 1 SPACE SPACE 1 - - 33 36 - - 1 SPACE SHUNT TRIP 38 20 12 1 REC: OFFICE 40 20 12 1 REC: TO GO AREA 42 - - 1 SPACE 19 WALK IN COMPRESSOR (CU-1) 3 12 20 0.8 0.8 0 23 0.9 0 0 0 0 3 PANEL H 2 100 0 0 0 13.7 0 6.7 39 2 20 12 1 KEF-1 #4 4 15 12 1 HOOD CONTROLS<S #4 6 20 - 1 NOTES SPACE #4 15 12 3 KSF-3 & KEF-2 14 - - 1 SPACE 16 - - 1 SPACE 18 - - 1 SPACE 20 15 12 1 22 - - 1 SPACE 24 - - 1 SPACE 26 - - 1 SPACE 28 - - 1 SPACE 30 - - 1 SPACE 32 - - 1 SPACE 34 - - 1 SPACE 36 - - 1 SPACE 3 PANEL B HOOD CONTROLS & LTS #4 10.6 8.6 10.7 34.7 TOTAL CONNECTED kVA: 150 1/0 40 32.7 9.2 42 32.9 100.3 DEMAND kVA: 97.2 24.5 DEMAND AMPS: 85.1 PANEL RMS SYM. AMPS: SEE RISER DEMAND AMPS: 269.9 68.0 1. 2. 3. 4. PANEL SHALL BE EQUAL TO SQUARE D NQ. GFI - PROVIDE GFCI BREAKER FOR CIRCUIT. GFCI RECEPTACLES MAY BE USED IN LIEU OF GFCI BREAKERS SO LONG AS THE DEVICE(S) CONFORM TO NEC CODE REQUIREMENTS FOR GFCI PROTECTION & ACCESSIBILITY. TC - CIRCUIT THROUGH 7-DAY PROGRAMMABLE ASTRONOMICAL TIME SWITCH WITH AUTO-DUSK. C - CIRCUIT THROUGH LIGHTING CONTACTOR. SEE DETAIL. 1. 2. 3. 4. PANEL SHALL BE EQUAL TO SQUARE D NQ. PROVIDE HACR BREAKERS FOR HVAC EQUIPMENT. WIRE SHUNT TRIP TO HOODS FIRE SUPRESSION SYSTEM. WIRE VIA HOOD CONTROL PANEL. PANEL "A" LOAD SUMMARY LOAD TYPE PANEL "B" LOAD SUMMARY LOAD TYPE LIGHTS (2,950 SQ FT @ 2W/SQ FT < CONN. LOAD) kVA CONN. DEM. FACT. kVA DEM. 6.2 1.25 7.8 1st 10 kVA 3.6 1.0 3.6 REMAINDER 0.0 0.5 0.0 SHOW-WINDOW (36 FEET @ 125%) 0.6 15.0 9.0 ELEC HEAT 0.0 1.0 0.0 LARGEST MOTOR 7.0 1.25 8.8 REMAINDER 26.7 1.0 26.7 47.4 0.65 30.8 SIGN CIRCUIT(S) 1.2 1.25 1.5 RECIRC. PUMP, EX. FAN 0.9 1.25 1.1 HOOD FANS & CONTROLS 4.4 1.25 5.5 LOADS ON 300 AMP FUSED DISC. @ METER DEM. FACT. kVA CONN. LOADS ON 150 AMP BREAKER @ PANEL A LIGHTS (2,950 SQ FT @ 2W/SQ FT < CONN. LOAD) kVA DEM. 6.2 1.25 7.8 1st 10 kVA 3.6 1.0 3.6 REMAINDER 0.0 0.5 0.0 SHOW-WINDOW (36 FEET @ 125%) 0.6 15.0 9.0 RECEPTACLES RECEPTACLES HVAC & R KITCHEN EQUIPMENT # PIECES COOKING EQUIPMENT: 11 12.2 0.65 7.9 0.7 1.25 0.9 RECIRC. PUMP, KITCHEN EQUIPMENT # PIECES COOKING EQUIPMENT: 16 SIGN CIRCUIT(S) 1.2 TOTALS TOTAL AMPS @ SERVICE ENTRANCE EQUIP. GROUND BUS -DESCRIPTION- 38 41 DEMAND kVA: 30.7 0 0 35 #3 0 0 0 37 0 0.5 21 SANDWICH UNIT GFI POLE 12 0 17 1 0.9 0 4.8 - WIRE SIZE 10 2.8 4.8 CKT# BRK SIZE 8 2.9 20 0 0.8 15 WARMING CABINET GFI 0.5 3.7 9 60 C 1.0 3.7 22 24.5 NEMA 1 B 3 45 4 A 3.6 9.2 PANEL RMS SYM. AMPS: SEE RISER 208 V 3 PHASE, 4 WIRE LOAD PER PHASE WIRE SIZE -DESCRIPTION- NEXT TO BACK DOOR AMPS: 400-MLO BRK SIZE 1.0 0.8 - 13 C 1.0 1.0 VOLTAGE: 208Y/120V NEMA 1 B 1.2 12 35.0 FLUSH MOUNTED A 1.2 14 0 10.6 10 PANEL: B LOAD PER PHASE WIRE SIZE 8 0 0 13.7 1. 2. -DESCRIPTION- POLE 3 PHASE, 4 WIRE AMPS: 200-MLO 6 1.8 9 CONVECTION OVEN WIRE SIZE 30 4 3.7 1.2 BRK SIZE 2 3 7 CKT# 3.3 5 SPACE NEMA 1 LOAD PER PHASE WIRE SIZE VOLTAGE: 208Y/120V NEXT TO BACK DOOR 208 V 1.25 24.5 1.5 30.7 3 PHASE 85.1 WALK IN COOLER COMPRESSOR/EVAP. NEUTRAL BUS 208 V TOTAL AMPS @ GROUNDING ELECTRODE CONDUCTOR TO PRIMARY GROUNDING ELECTRODE SIZED AS INDICATED ON POWER RISER DIAGRAM. 2.5 EXOTHERMIC WELD TO EFFECTIVELY GROUNDED BUILDING STEEL WHERE AVAILABLE, PER NEC 250.52(A)(2), BONDING JUMPER #4 AWG CU. CONNECTION TO GROUND RING, PER NEC 250.66(C), NOT REQUIRED TO BE LARGER THAN THE GROUND RING CONDUCTOR. 400/3/300 CONNECTION TO ROD, PIPE OR PLATE ELECTRODE, PER NEC 250.66(A), NOT REQUIRED TO BE LARGER THAN #6 AWG CU. BOLTED TYPE CONNECTION OR EXOTHERMIC WELD. NOTE 5&13 NOTE 7 100.5 3 PHASE 2.5 97.2 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 plumbing mechanical electrical 269.9 NOTE 9 PANEL A PANEL B PANEL H 400A MLO 208Y/120V 200A MLO 208Y/120V 100A MLO 208Y/120V NOTE 13 NOTE 13 NOTE 13 M CONNECTION TO CONCRETE ENCASED ELECTRODE, PER NEC 250.66(B), NOT REQUIRED TO BE LARGER THAN #4 AWG CU. HAND HOLE FOR INSPECTION. 1.0 NOTE 10 NOTE 14 GROUND CLAMP ON EFFECTIVELY GROUNDED METALLIC WATER MAIN, PER NEC 250.52(A)(1) maple ENGINEERING, pllc TOTALS INTERSYSTEM BONDING TERMINATION BUS, PER NEC 250.94, BONDED WITH MINIMUM #6 AWG CU. 6/16/14 UTILITY XFMR 300 kVA NOTE 4 HAND HOLE FOR INSPECTION. GRADE TAZIKIS, SUITE 250 FINISHED GRADE 20' MIN. TO SERVICE #1 METER CENTER NOTE 3 & 6 CU GROUND ROD CONCRETE ENCASED ELECTRODE PER NEC 250.52(A)(3). 1/2" REBAR OR #4 BARE COPPER (MINIMUM). BARE COPPER #2 AWG MINIMUM CONDUCTOR GROUND RING BURIED AT LEAST 30" BELOW GRADE, MIN. 20' LONG PER NEC 250.52(A)(4) NOTE 8 BELOW FINISH GRADE, NEC 250.52(A)(5) 1 ELECTRICAL POWER RISER NO SCALE RISER DIAGRAM NOTES: NONMETALLIC PROTECTIVE SLEEVE 1. ALL EXISTING ITEMS ARE SHOWN IN FAINT. NEW ITEMS ARE SHOWN IN BOLD. 2. E.C. TO CONFIRM RISER BEFORE BEGINNING WORK. CONTACT ENGINEER IF SIGNIFICANT DISCREPANCIES ARE FOUND. 3. NOTE: GROUNDING ELECTRODES SHALL BE PROVIDED IN ACCORDANCE WITH NEC SECTION 250. ALL GROUNDING ELECTRODE CONDUCTORS SIZED AS INDICATED ON POWER RISER DIAGRAM. ALL METHODS OF CREATING THE GROUNDING SYSTEM MAY NOT BE REQUIRED OR AVAILABLE. 2 GROUNDING DETAIL SECONDARY CONDUCTORS SIZED, PROVIDED & INSTALLED BY E.C.. CONFIRM INSTALLATION W/ UTILITY BEFORE BEGINNING WORK. RE-USE EXISTING 4" CONDUIT TO EXTENT POSSIBLE. FIELD SHORT CIRCUIT CALCULATION VERIFY. 4. MAXIMUM AVAILABLE FAULT CURRENT IS BASED ON A THE TX KVA, IMPEDANCE (%Z), WIRE SIZE & LENGTH SHOWN BELOW. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF TRANSFORMER CHARACTERISTIC INDICATE A HIGHER FAULT CURRENT IS POSSIBLE (HIGHER KVA, LOWER IMPEDANCE, LARGER SECONDARY WIRE, SHORTER SECONDARY LENGTH, ETC). NO SCALE TX KVA TX %Z VOLTAGE PHASE # COND. WIRE SIZE (COPPER) 300 2.5 208 3 1 CURRENT (L TO L) MULT. (ISC) TX ISC f M 833 40.00 33309 350kcmil WIRE L. (FEET) 50 ISC (AMPS) 320A METER BASE PER UTILITY REQUIREMENTS. METER BY UTILITY. 5. SERVICE ENTRANCE RATED WEATHERPROOF DISCONNECT SIZED AND FUSED AS INDICATED. 6. (4)#350kcmil CU, USE EXISTING 4" CONDUIT. 7. (4)#350 kcmil, 2 1/2" CONDUIT. 8. #1/0 CU MAIN GROUNDING ELECTRODE CONDUCTOR TO GROUNDING SYSTEM (SEE DETAIL). BUILDING SHALL HAVE ONE GROUNDING ELECTRODE SYSTEM. WIRE "C" 22736 9. (4)#1/0 CU, #8 GND, 1 1/4" CONDUIT. 10. (4)#2 CU, #8 GND, 1 1/4" CONDUIT. 11. PROVIDE PLACARD AT PANEL(S)/DISCONNECT(S) INDICATING SUITE/TENANT & PANEL SERVED. 12. PROVIDE PLACARD INDICATING AVAILABLE AIC FAULT CURRENT (NEC 110.24) 13. ELECTRICAL DISTRIBUTION SYSTEM TO HAVE AN OVERALL AIC AND SHORT CIRCUIT RATING OF 0.6100 0.6211 20689 Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 22K AMPS. CIRCUIT BREAKERS WITH A LESSER LABELED AIC RATING MAY BE USED IF THOSE BREAKERS ARE PAIRED WITH AN UPSTREAM BREAKER OR FUSE AS PART OF A UL SERIES RATED COMBINATION. PAIRED DEVICES MUST BE IN ACCORDANCE WITH NEC 240.86. LABEL PER NEC 110.22(C). CONFIRM W/ EQUIPMENT MFG BEFORE PURCHASE. E.C. TO PROVIDE FIELD INSPECTOR WITH MFG'S DOCUMENTATION REGARDING UL SERIES RATING OF PAIRED BREAKERS/FUSES. 14. (4) #350 kcmil CU, #3 CU GND, 2 1/2" CONDUIT. E-4 PANEL SCHEDULE & RISER FIRE RATING LEGEND 1-HR WALL NOTIFICATION DEVICES F INPUT DEVICES FS TS F BACK FLOW PREVENTER FIRE ALARM CONTROL PANEL FS F PULL STATIONS T A TEMPERATURE SENSOR F S TWO DEDICATED TEL. LINES TS SPRINKLER RISER 120V A S ANSUL (HOOD) D D 1. SMOKE DETS. RISER NOTES: 1. 2. 3. FIRE ALARM SYMBOL LEGEND GENERAL FIRE ALARM NOTES 2. FIRE ALARM SYSTEM IS EXISTING. COORDINATE NEW DEVICES WITH EXISTING FA SYSTEM TYPE, MODEL, AND REQUIREMENTS. PROVIDE ALL PROGRAMMING AND FINAL CONNECTION BY A FACTORY TRAINED TECHNICIAN. FIRE ALARM CONTROL PANEL, SEMI-FLUSH MOUNTED. THE FIRE ALARM CONTRACTOR IS TO BE HELD TO THE SAME REQUIREMENTS AS THE ELECTRICAL CONTRACTOR. FIRE ALARM CONTRACTOR SHALL REVIEW ELECTRICAL PLANS AND ELECTRICAL "GENERAL NOTES" BEFORE COMPLETING BID. FIRE ALARM CONTRACTOR IS TO VERIFY EXISTING FIRE ALARM SYSTEM HAS BATTERY AND VOLTAGE CAPACITY TO HANDLE ADDITIONAL DEVICES. PROVIDE FIRE ALARM SHOP DRAWINGS IF REQ'D TO LOCAL AHJ. EXISTING FIRE ALARM DEVICES ARE SHOWN IN FAINT. NEW OR RELOCATED DEVICES ARE SHOWN IN BOLD. 3. RISER IS GENERIC IN NATURE. CONTRACTOR TO FIELD VERIFY EXACT LAYOUT AND EQUIPMENT PRESENT. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE AN UPDATED FIRE ALARM LAYOUT PLAN AT THE FACP. 5. TESTING OF THE FIRE ALARM SYSTEM SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. FIRE ALARM RISER DIAGRAM 4 ALL FIRE ALARM WIRING SHALL BE IN CONDUIT OR AS ALLOWED BY NEC OR LOCAL AHJ. AN FIRE ALARM SYSTEM ANNUNCIATOR PANEL, 48" A.F.F. F FIRE ALARM SYSTEM MANUAL PULL STATION, 48" A.F.F. F FIRE ALARM SYSTEM ALARM INDICATING DEVICE, HORN/STROBE, 80" A.F.F. S FIRE ALARM SYSTEM ALARM INDICATING DEVICE, STROBE, 80" A.F.F. F FIRE ALARM SYSTEM ALARM INDICATING DEVICE, HORN/STROBE, CEILING. S FIRE ALARM SYSTEM ALARM INDICATING DEVICE, STROBE, CEILING. M FIRE ALARM SYSTEM ALARM INDICATING DEVICE, MINI-HORN. 80" A.F.F. H FIRE ALARM SYSTEM ALARM INDICATING DEVICE, MINI-HORN/STROBE 80" A.F.F. S FIRE ALARM SYSTEM CEILING MOUNTED SMOKE DETECTOR, MULTI-MODE TYPE. "R" INDICATES FOR ELEVATOR RECALL FUNCTION AND INTERLOCK WITH ELEVATOR CONTROLLER. D FIRE ALARM SYSTEM DUCT SMOKE DETECTOR, PROVIDED AND WIRED BY E.C., INSTALLED BY M.C. NO SCALE FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX SYSTEM OUTPUTS C A A A SYSTEM INPUTS NOTIFICATION B C D E F G H I J MAGNETIC DOOR HOLDER (SUPPLIED WITH DOOR HARDWARE), CONNECT TO LOCAL SMOKE DETECTOR. TS FIRE ALARM SYSTEM TAMPER SWITCH. FIELD COORDINATE EXACT QUANTITY AND LOCATIONS. FS FIRE ALARM SYSTEM FLOW SWITCH. FIELD COORDINATE EXACT QUANTITY AND LOCATIONS. REQUIRED FIRE SAFETY CONTROL TU A C TE TU C O A A C TE MM TU O A U A AT D NA C TU E C IBL LA E R M A AT OM A C TU E A MO LA SIG R U N N M A AT D A S C TU E C IBL UP SIG L I E ER N ND O A A IC VI AL C TE MM SU TU A PE SO O A TO A AT UD N T RV RY R C I E R B I TU ZO LE OU SO SIG D AT N B RY N T IS E LE R SI AL O PL E G O G U S IN R TR AY EN D D BL IGN NA E IC E E L C A R A V A H S N TO SM AN AL ICE IG L IN N E R D G A IT V A IC FI E O AC DD L A R R U TO F E E A R TI SS A ST LA A O R R TU N S ALA EL M S IG E R SI M N R AS G A EC E N L IND A M A IC L A L R TO A EC L E GN TO C LE ET A R EN VA IC A LL T A C R TU EL TO LL A Y L A EV R TE A ST TO HE A LD W TO R TI R EC A C O D R LO N O A N TO O L I SE N A L R G LT U S F A LO N TO E LO LL R EL NA OR SH CK SM EV TE O EX U K A T TO RE D ITS E D A O R CA C A A W TU M C LL N N A PE D A B A C R S FLO C TE RE O S S TU FL O N P R O EC TR A AT O C TU E S R TIV OL P D E T A R O A TE AIR E O I SM W SS R H RS EL U A A R O N L C K TI P IZA D E VA EX RE TI LIN SS ON G TE H EQ A H U UR O U ST IZ O IP A D M TI EX EN O N H T A U ST ,D IS A B LE H O O D M A K EU P FACP ANNUNCIATION DH N O TI A N T O R S TI L A TO A T VA TR L S E EN RA EL C T M O TO EN C L FR A N TO ER G L I W A S Y GN PO R I F O SO E S I L V BL R VA O PE OU M U R E S T R IT IT ED SM SM Y N N A A A EL TR TR D K L M N O P Q R S T U V W X Y 1 FIRE ALARM SYSTEM AC POWER FAILURE 1 2 FIRE ALARM SYSTEM LOW BATTERY 2 3 OPEN CIRCUIT 3 4 GROUND FAULT 4 5 NOTIFICATION APPLIANCE CIRCUIT SHORT 5 6 BUILDING MANUAL PULL STATIONS 6 7 CORRIDOR SMOKE DETECTORS 7 8 AREA SMOKE DETECTORS 8 9 HVAC AIR DUCT SMOKE DETECTORS 9 10 AREA HEAT DETECTORS 10 11 HOOD OR ROOM FIRE SUPPRESSION SYSTEM ALARM 11 12 SPRINKLER TAMPER SWITCH 12 13 SPRINKLER WATER FLOW IN BUILDING 13 14 SPRINKLER WATER FLOW IN ELEV EQUIP RM OR SHAFT 14 15 ELEV EQUIP RM AREA SMOKE DETECTOR 15 16 ELEV SHAFT AND ELEV EQUIP RM HEAT DETECTORS 16 17 ELEV LOBBY SMOKE DETECTORS - UPPER FLOORS 17 18 ELEV LOBBY SMOKE DETECTOR - RECALL FLOOR 18 19 ELEV CONTROLLER POWER SHUNT TRIP STATUS 19 20 FIRE PUMP POWER FAILURE/PHASE REVERSAL 20 21 FIRE PUMP RUNNING 21 22 FIRE PUMP SYSTEM NOT IN AUTOMATIC 22 23 LEGALLY REQUIRED GENERATOR SYSTEM LOW FUEL 23 24 LEGALLY REQUIRED GENERATOR NOT IN AUTOMATIC 24 25 AREA OF REFUGE TWO-WAY COMMUNICATIONS STATUS 25 26 - 26 27 - FIRE ALARM SYSTEM ROOM TEMPERATURE SUPERVISORY SWITCH. ALARM SHALL INDICATE A T COORDINATE EXACT QUANTITY AND LOCATIONS. 120V MULTI-STATION SMOKE DETECTOR WITH BATTERY BACK-UP. CONNECT TO NEAREST 120V CIRCUIT. FOR UNITS WITH 2 OR MORE SMOKE DETECTORS, DETECTORS MUST BE INTERLOCKED SUCH THAT THEY ALL ALARM AT ONE TIME. "ADA" - UNITS SHALL HAVE 177CD STROBE NOTIFICATION IN SLEEPING AREAS. SD A ANSUL HOOD SYSTEM "ALARM" OUTPUT. F NEW OR RELOCATED DEVICE F EXISTING DEVICE TO REMAIN F DEMO'D DEVICE OR DEVICE TO BE RELOCATED. GENERAL NOTES - THIS SHEET 1. 3 B C D E F G H I J K L M N O P Q R S T U V W V maple TAGGED NOTES - THIS SHEET FIRE ALARM NOTIFICATION DEVICES NOT PROVIDED AS FIRE ALARM IS NOT REQUIRED FOR SPACE PER 2012 NC FIRE CODE SECTION 904. BUILDING IS SEPARATED MIXED-USE. W FIRE ALARM DEVICE MATRIX ENGINEERING, pllc 1405 HILLSBOROUGH ST RALEIGH, NC 27605 LIC.#: P-0990 P:919-341-4247 F:919-890-3797 HOOD FIRE SUPPRESSION SYSTEM TO BE INTERLOCKED TO BLDG FIRE ALARM SYSTEM. UPON ACTIVATION OF HOOD SUPPRESSION SYSTEM BLDG FIRE ALARM SYSTEM IS TO ACTIVATE. 1 27 A 6/16/14 2 MANUAL PULLSTATIONS OMITTED AS THEY ARE NOT REQUIRED PER 2012 NCFC SEC (907.2.1 GROUP A EXCEPTION). BUILDING FIRE SPRINKLER SYSTEM IS INTERLOCKED WITH BLDG FA SYSTEM. CONTRACTOR TO VERIFY INTERLOCK BEFORE BEGINNING WORK. 3 NEW FIRE ALARM INPUT DEVICE. plumbing mechanical electrical NO SCALE ROOF DECK/FLOOR ABOVE MEN INSTALL PER NEC MOUNT ON APPROVED BOX MOUNT NOTIFICATION DEVICES ON APPROVED BOXES 6" MIN. SUPPLY DIFFUSER OR RETURN/EXHAUST OPENING SMOKE/HEAT DETECTOR 2 STORAGE CONDUIT HALL DINING AREA 4 WOMEN DINING AREA 3 DINING AREA 2 1'-0" MAX. CEILING 0'-4" MIN. 3'-0" MIN. HORN STROBE GRAPHIC ANNUNCIATOR EXIT HORN STROBE 4" MIN. TO GO ORDERS SMOKE/HEAT DETECTOR FACP BACK HALL CAN WASH CUSTOMER QUEUE RTU 3'-8" (3'-6" MIN. 4'-0" MAX.) 8'-0" MAX. (TOP OF DEVICE) 5'-0" MAX. 6'-8" MIN. (BTM OF DEVICE) HINGED SIDE D 3 2 2 3 MANUAL PULL STATION RTU D FRONT KITCHEN A 1 OFFICE 3 DINING AREA 1 NOTE: NFPA 72 & ADA DEVICES INSTALLATION REQ'S 3 CATERING STORAGE RTU D A 1 Project Number :LAG-1404 Drawn By: MJL, RDG, RSA Date: 06-16-14 FLOOR 2 FIRE ALARM DEVICE LOCATIONS NO SCALE 3 PREP KITCHEN/ DRY STORAGE 1 FIRE ALARM PLAN SCALE: 1/8" = 1'-0" FA-1 FIRE ALARM PLAN