Lensai Leaflet Artiflex Toric.indd

Transcription

Lensai Leaflet Artiflex Toric.indd
OPHTEC
| Refractive Surgery
ARTIFLEX® TORIC PHAKIC IOLS
The jump to perfection in Refractive Surgery
The ARTIFLEX® Toric PIOL is the latest extension of the successful ARTISAN® concept. It combines a spherical and
cylindrical correction for low, moderate and high myopic eyes. The flexibility of the silicone optic enables
implantation through a small incision, which results in almost no induced astigmatism as well as fast recovery.
Main Features & Benefits
 IRIS FIXATION
ENSURES FIXED AND PRECISE POSITIONING
ON MARKED AXIS
 SMALL INCISION
 NO ROTATION POSTOP
 LONG TERM SAFETY
Material optic:
Material haptic:
Body Ø:
Overall Ø:
Polysiloxane
UV-absorbing PMMA
6.0 mm
8.5 mm
 OPTIMAL CLEARANCE FROM
VITAL TISSUES
 QUICK RECOVERY
OPHTEC
| Refractive Surgery
ARTIFLEX® TORIC PIOLS
Surgical Technique
The surgical technique of the ARTIFLEX® Toric PIOL is similar to the ARTIFLEX®
non-toric PIOL, except for the need to fixate the lens on a precise axis.
Preoperative determination and marking of the cylinder axis is therefore
essential.
// ARTIFLEX® Instruments
ARTIFLEX® Toric PIOLs are available with a 0˚or a 90˚cylinder. This enables
implantation of the Toric PIOL in a horizontal or slightly oblique position
through a 12 o’clock incision, as well as in a more or less vertical position
through a temporal incision.
The unique and versatile fixation method enables exact positioning of
the PIOL in any meridian and centration on the pupil, without the risk
of lens rotation or decentration. The design of the claws guarantees
long term stability as has been proven over the last 30 years.
OD 125
ARTISAN® / ARTIFLEX®
Disposable Enclavation Needle
BO 150
VacuFix™ Disposable
Vacuum Enclavation System
OD 110
ARTIFLEX® Disposable
Insertion Spatula
Power calculation
As a unique service, OPHTEC provides a recommendation for the lens
power and a special drawing indicating the proper axes in which the lens
should be implanted for each individual case.
ARTIFLEX® Toric PIOLs are customized devices provided to meet individual
needs.
OF 106
ARTIFLEX® Reusable
Implantation Forceps Right
OF 105
ARTIFLEX® Reusable
Implantation Forceps Left
Availabilty
The dioptric power range includes a spherical correction from -1.0 to -13.5 D
in combination with a cylinder correction from -1.0 to -5.0 D.
OF 115
ARTIFLEX® Reusable Manipulator
ARTIFLEX® Toric PIOL with 0˚ and 90˚ minus cylinder
Dioptric Powers
Negative Cylinder Range
Axis: 0˚ and 90˚
Cylinder Power
Minimal Sphere Power
D
D (0.5 increments)
-1.0
-1.0 to -13.5
-1.5
-1.0 to -13.0
-2.0
-1.0 to -12.5
-2.5
-1.0 to -12.0
-3.0
-1.0 to -11.5
-3.5
-1.0 to -11.0
-4.0
-1.0 to -10.5
-4.5
-1.0 to -10.0
-5.0
-1.0 to -9.5
Imported & Distributed by Lensai Ophthalmic Private Limited | 408, Sahajanand Palace, Anand Nagar Road, Satellite, Ahmedabad-380 051. India.
Tel: +91-79-30612085 | Fax: +91-79-40055664 | [email protected] | www.lensai.com
Manufactured by OPHTEC BV | P.O. Box 398 | 9700 AJ Groningen | Schweitzerlaan 15 | 9728 NR Groningen | The Netherlands | T: +31 50 5251944 | F: +31 50 5254386
E: [email protected] | ©OPHTEC BV 2013 | L72-MD20-3 A | Information on this document is subject to modification
www.ophtec.com