inpond all-in-one with UVC 1400

Transcription

inpond all-in-one with UVC 1400
Blagdon Inpond with UVC AW v2.qxd
Established over 40 years ago, Blagdon are
committed to producing a comprehensive
range of high quality, easy to use, pond
equipment. An ongoing programme of
research and development ensures
excellent performance and value for all
their customers. This product excellence is
demonstrated by Blagdon’s award winning
range of water gardening equipment. As
a result Blagdon’s reputation for quality is
unrivalled amongst experienced pond
gardeners and retailers alike.
Blagdon - The Pond Masters
The name you can rely on
Interpet, Vincent Lane,
Dorking, Surrey, RH4 3YX
Leaflet Code: BG Inpond 1-b
22/12/10
14:34
Page 1
inpond
all-in-one
with UVC
1400
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 3
CONTENTS
Getting to know your Inpond
Parts descriptions / spares codes - with exploded diagram
inpond
all-in-one
with UVC
1400
Congratulations on buying a
Blagdon All-in-One.
Manufactured with advanced technology to
create a clean and healthy pond for your fish.
2
2-4
Technical specifications
4
Pump performance / flow chart
4
Installation
5
Electrical installation
Installing Inpond
Installing UVC
5
6, 7 & 8
9 & 10
Maintenance and cleaning
11
Cleaning
11
Step by step guides
12
Routine maintenance
13
Annual maintenance
13
Winter storage
13
Troubleshooting
Troubleshooting and maximise performance
16
16, 17 & 18
Faults - problem procedure
19
Consumer advice contact details
19
Returning faulty pumps
19
Guarantee
20
IMPORTANT
Please attach proof of purchase to this manual
and file in a safe place.
1
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 5
GETTING TO KNOW YOUR INPOND
GETTING TO KNOW YOUR INPOND
30
29
31
28
27
25
8
36
26
27
7
38
6
BLACK
5
GREEN
37
4
33
23
3
36
22
21
2
24
32
20
43
19
35
9
18
11
42
10
1
34
2
12
41
13
14 15
16
40
39
17
No.
Part Description
Spare Code
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
35.
36.
37.
38.
Filter body
UVC Contact chamber
Polymer wool pad
Polymer wool cartridge
Medium foam
Coarse Foam
Filter lid
Locking handle
Locking cap
Double threaded attachment
11/2” Connecting pipe
Pump locking nut
11/2” Impeller cover
O ring
Impeller complete
Pump motor unit
Pump back panel
Light level sensor - Photo sensor
Automatic LED Spot light
O ring
LED lamp
LED lamp cover clear
LED lamp screw cap
Ball Joint
30cm Telescopic extension pipe
20cm extension pipe
Control valve & diverter
Fountain attachment
Water bell large
Daisy super
Daisy
Pump cable Low Voltage 10m
Low voltage transformer + 3m 230v
UVC electronics & cap
Ceramic media
Ceramic media
Screw on hosetails 1/2” 12.5mm
1
/2” 12.5mm Silicone hose; not included
1
/2” 12.5mm Control valve hose attachment
N/A
N/A
1051166
N/A
1051170
1051170
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1017800
N/A
N/A
N/A
1051330
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1017763
1017763
1017763
N/A
1017763
N/A
N/A
1051187
N/A
N/A
N/A
3
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 7
INSTALLATION
GETTING TO KNOW YOUR INPOND
Electrical installation
No.
Part Description
Spare Code
39.
40.
41.
42.
43.
PL 5W UVC lamp
Quartz sleeve
UVC O ring
13m cable
IPX7 Starter UVC + 10m of cable
1041041
N/A
N/A
N/A
N/A
The power supply must meet the specifications on the product.
The pump is intended to be used with either a weather-proof
cable connector or permanently connected to the fixed wiring
in the main system other than by means of a plug and socket.
The cores in the supply cable are coloured in accordance with the following
code: Brown = Live, Blue = Neutral, Green/Yellow = Earth.
Pump performance / flow chart
The electric cable is permanently connected and sealed in the motor body.
If the supply cable is damaged the pump must not be used.
Tech Specification:
Cable Fitted
13 metres
Voltage
12V
Pump
Watts
10
700ltr (154 gal)
Safety Rating
IP68
1.25m max head (4.1”)
Maximum Depth
_
1.25 metres CC
12v Low voltage
Maximum Lift
1.25 metres / 4’1”
IP56 Weatherproof transformer
Do not use the supply cable to lift the pump as this may cause damage.
WARNING - THIS PUMP MUST BE EARTHED
10m of low voltage cable
10w IP68
Lift
Flow rates lph
2.0 metres
-
1.5 metres
-
1.0 metres
300 lph
0.5 metres
520 lph
0.0 metres
700 lph
Flow is given as optimum rate
A Residual Current Device (RCD), also know as the Residual
Current Circuit Breaker (RCCB), with a tripping current not
exceeding 30mA must be installed in the supply circuit.
A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the fixed wiring.
LED
For permanent installations to the mains supply, it is necessary to conform to
the regulations of the local electricity authority and this would include the use
of a metal or plastic conduit to protect the cable.
Photo sensor activated
0.76w
UVC
Attention has been drawn to the fact that special rules may exist concerning
the installation of your pond pump (i.e. local building regulations).
5w PL lamp
13m of cable
These pumps must not be used in swimming pools, or areas where people are
in contact with the water.
230v 50Hz
IP68
Always disconnect the mains electricity supply whilst the equipment is being
installed, repaired, maintained or handled. Consult a qualified electrician if in
any doubt about wiring this product to the main supply.
Specification chart
Warning - The Inpond pump is provided with a thermal
cut out that temporarily switches off the pump in case of
overheating and the pump may automatically restart.
1400
4
1400ltr/307.95gal 700ltr/153.97gal 700ltr/153.97gal
525ltr/116gal 262ltr 58gal
18W
25mm/1”
5
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 9
INSTALLATION
Locating your Inpond All-in-One
The Inpond pump and filter should be located on a firm and level base in the
pond/water feature in a depth of at least 10cm, but no more than 1.25m.
It is advisable to keep the pump off the bottom of the pond to avoid silt
entering the pump causing excessive wear and increasing pre-filter cleaning.
Fountain
INSTALLATION
CONVENIENT INSTALLATION
The Inpond All-in-One can be installed either powering a waterfall or
fountain.
Waterfall or feature option
WATERFALL OR FEATURE
Make sure there is ample cable from mains supply. Place filter in desired
location. Add Fountain extension pipes so fountain head is above surface of
the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’
diagram below. See "Getting to know your Inpond" for parts and descriptions.
FOUNTAIN
MAX 70cm
HOSE
Inpond Filter
ADJUSTING FLOW CONTROL
Turn clockwise to increase anti-clockwise
to reduce flow.
Fountain option
BELL FOUNTAIN
Adjust bell by
moving head higher
for small bell and
lower for a wider
bell shape.
MIN 40cm
Inpond Filter
TYPICAL INSTALLATION
The flow control valve is fitted with a diverter to ensure there is always pond
circulation.
Tip: Ensure that any fountain or feature fitted does not empty water out of
pond/water feature.
Water Feature
Install as for Fountain. Depending on water feature to be supplied, your
Inpond All-in-One can be used with the flow control and the 1/2" hose fitting.
Hose clips should be used to secure hose. See page 8, fitting a waterfall or
feature.
6
7
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 11
INSTALLATION
MAINTENANCE & CLEANING
WATERFALL INSTALLATION
IMPORTANT - Failure to carry out routine maintenance leaving
the pump under reduced or no flow conditions for long periods
will result in a shorter pump life and will invalidate the
guarantee.
IMPORTANT
The outlet hose should be smooth bore (not corrugated) pipe installed over
as short a distance as possible with no kinks or bends.
We recommend that Blagdon smooth bore clear hose or Blagdon heavy duty
smooth bore black hose are used.
INSTALLING THE
WATERFALL OR FEATURE
CONNECTING
OUTLET HOSES
Routine Maintenance
Carry out routine maintenance when flow is visibly reduced.
Waterfall or
Feature
12.5mm /
1
/2”
The Blagdon Inpond All-in-One pump is centrifugal with a magnetic impeller
movement driven by a watertight synchronous motor. They require minimum
cleaning, only periodic cleaning of the impeller is necessary.
1. Switch off electricity.
2. Remove filter from pond (do not use the cable to lift the pump.)
Recommended
HOW IT WORKS - FLOW DETAIL
The recommended hose size
for your Inpond filter is stated
in the filter performance and
specification chart.
36
27
Flow control
Inlet grills
Coarse foam
Automatic LED
spot light
Photo Sensor
Always secure hose with a
jubilee clip.
38
Warming the hose in a bucket of
boiling water can aid fitting.
Always ensure that the smaller
diameter hosetail is cut off and
removed to prevent reduced
filter performance.
Use the shortest possible hose
lengths to minimise flow
restrictions.
Avoid folds and kinks in the
hose, which will reduce flow and
filter performance.
8
Low voltage
Pump
Locking
handle
37
24
Medium foam
Polymer wool
pad cartridge
36
21
UVC contact chamber
Inlets
Ceramic biomedia
16
9
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 13
MAINTENANCE & CLEANING
Opening and locking filter handle
Easy lift integrated locking handle
Locked
Note the handle is in the locked position
UVC INSTALLATION
UVC LAMPS & QUARTZ SLEEVE MAINTENANCE
The UVC lamp must be replaced every six months / once a season. It is
recommended that the lamp is replaced and reconnected in the spring.
The Quartz sleeve can become coated in lime scale build up in hard water
areas. This should be carefully removed from the quartz sleeve and cleaned
with a soft cloth.
A wet test must be carried out after maintenance to ensure there are no leaks
before the UVC is reconnected.
Locked
WET TESTING THE UVC
Handle is in the central position. This will
enable the filter and pump to be carried in
and out of the pond.
* Ensure the filter is not carried by the
pump cable.
Unlocked
The handle is in the unlocked position
allowing the filter media to be removed and
cleaned.
Foams may be cleaned vigorously in a bucket of pond water.
Adding Blagdon Bio Start after filter maintenance will help replenish these
beneficial bacterial populations and is highly recommended during the first
two months of operation when the filter is slowly being colonised.
Ceramic bio media
These will only need very occasional cleaning (once per year), but must be
rinsed in pond water to prevent damaging the beneficial bacteria which help
maintain a healthy pond.
10
IMPORTANT: A wet test of the UVC under operating conditions must be
carried out before the UVC or electrical supply is installed.
Connect the UVC to the Inpond following all installation instructions.
After running for 24 hours check for leaks.
TESTING/REPLACING THE UVC LAMP
IMPORTANT: Ensure that the mains supply is switched off and the power
isolated before removing the UVC cover.
1. Unscrew the UVC electronics cover cap.
2. Inspect the UVC cap and Quartz sleeve for water leaks.
3. If there are no signs of leakage reverse the procedure ensuring that the
Cover O-ring is in place.
4. This unit is protected by a micro switch that prevents the UVC light from
illuminating when the cover is removed even if the power is on.
5. In order to check that the UVC lamp is operating see page 19 section 2 on
how to view you UVC lamp.
11
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 15
UVC ELECTRICAL INSTALLATION
UVC ELECTRICAL INSTALLATION
WARNING - A Residual Current Device (RCD), also known as the
Residual Current Circuit Breaker (RCCB), with a tripping current not
exceeding 30mA must be installed in the supply circuit. A means of
disconnection from the supply having a contact separation of at
least 3mm in all poles must be incorporated in the wiring.
3
4
2
1
5
IMPORTANT: Please note all electrical work on garden lighting and power
installations must comply with part P of the building regulations. Failure to
comply is a criminal offence. If the installation of this product is not carried
out by a competent electrician who is registered under the Part P selfcertification scheme then you must notify the local building control
department before work begins. For further information and guidance on
this matter and other electrical installations in your home that might be
covered by the relevant legislation, contact your local authorities building
control department.
For permanent installations to the mains supply, it is necessary to conform to
the regulations of the local electricity authority and this would include the use
of a metal or plastic conduit to protect the cable.
If there has been any damage to the unit please return to the point of purchase
for inspection.
Attention has been drawn to the fact that special rules may exist concerning
the installation of your pond UVC (i.e. local building regulations).
This test should be repeated whenever the the bulb or quartz is changed.
This UVC must not be used in swimming pools, or areas where people are in
contact with the water.
Warning: Direct exposure to UVC light can damage your eyes or skin.
Electrical installation - UVC
Always disconnect the mains electricity supply whilst the equipment is being
installed, repaired, maintained or handled. Consult a qualified electrician if in
any doubt about wiring this product to the mains supply.
The power supply must meet the specifications on the product.
The cores in the supply cable are coloured in accordance with the
following code: Brown = Live, Blue = Neutral.
Do not use the supply cable to lift the UVC as this may cause damage.
12
Electrical Safety
UVC warning: Dangerous Ultra Violet radiation. The rays from
the UVC lamp are harmful to eyes and skin.
Always turn off UVC electrical supply before any maintenance.
To protect the UVC starter; never immerse in water.
Locate the UVC starter (part 43) 1m minimum from pond edge.
13
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 17
MAINTENANCE & CLEANING
MAINTENANCE & CLEANING
LED Automatic Photo Sensor
Polymer wool cartridge
/2“ hose fitting
1
The polymer wool pad may be washed a limited number of times before it
starts to lose efficiency and blocks rapidly.
Replacement packs of polymer wool are available from your retailer and are
quick and easy to replace.
See page 10 on how to remove the cartridge easily from the Inpond.
Active hinge
Automatic LED spot light
Ball joint
LED automatic sensor
Pump
If the LED light is not
required you can
permanently remove the
lamp (see removing lamp
section page 14).
- detects when light levels are low/dusk
The LED automatic sensor is positioned
on top of the motor body between the
outlet and the lamp. Ensure this is kept
clean from dirt and algae as it needs
sufficient light to activate correctly.
This extremely efficient lamp uses less
than 1 watt of electricity which
automatically turns on at dusk and
off at dawn.
Polymer wool cartridge
Annual maintenance of the filter
Check for wear. Once a year you should dismantle your Inpond. Dismantle
the filter examining all the parts for wear or damage, replacing any parts
showing obvious signs of wear and/or damage (see getting to know your filter
for replacement codes and parts descriptions on page 2 & 3).
Polymer wool pad
23
Annual maintenance of the pump
Once a year you should service your pump.
Dismantle pump and examine all parts for wear or damage, replacing any
parts that show obvious wear and/or damage (see getting to know your
Inpond for parts/description and replacement parts codes). Particular care
should be taken to examine the cable entry points.
Removing LED Lamp
22
Replacing or removing the lamp
can be easily done by unscrewing
part 23 from the lamp holder
(part 19) then part 22 will be able
to be removed. Allowing the lamp
to be disconnected (part 21).
20
Annual maintenance of the UVC
19
Check for wear. Once a year you should dismantle your Inpond UVC section.
Dismantle the UVC containing all the parts for wear and damage, replacing any
parts that show obvious signs of wear or damage (see getting to know your
Inpond filter for replacement codes and parts descriptions on pages 2 & 3).
21
Pump
IMPORTANT - Ensure that the mains supply is switched off and the power
isolated before removing the lamp cover.
14
Winter Storage
The Inpond filter and pump can be run in the pond during the winter but care
should be taken to ensure that it is fully immersed and cannot freeze solid. If
the pump is not used during the winter follow the annual maintenance
procedure and store frost-free in the house or garage until spring.
15
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 19
TROUBLESHOOTING
Inpond Filter
Filter leaks
TROUBLESHOOTING
Inpond Pump
Problem
• Check that the filter outlet nut and O ring have been correctly assembled
and that they are hand tight.
Low flow from pump
• PTFE tape may be needed to give a water tight seal and should be applied to
outlet hosetails.
2. Follow monthly cleaning procedure.
• Always secure the filter outlet hose with a jubilee clip.
1. Follow routine cleaning procedure if no improvement.
3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed
or kinked.
Cloudy/brown water
4. Keep the height that water is to be pumped from the water surface (called
Head) to a minimum. The higher the head the lower the flow rate and the
more wear on the pump.
• The flow rate / pond turnover is to high or to low. Check that you have
correctly calculated the pond volume and that pump flow rate is within
limits.
5. Use the largest diameter, smoothest bore pond hose over the shortest
distance and keep hose fittings to a minimum. This removes frictional loss
of flow and so increases pump flow rates.
• Insure that the filter is installed on a flat and level base.
• The filter is not being supplied with water 24 hours a day. Do not turn off
your pump. Continuous running is needed to maintain a clean
and healthy pond.
• The filter foam pads are insufficiently blocked to trap the fine waste. Treat
with Blagdon Clear Pond treatment.
• The water is extremely dirty, remove pond waste and leaves - carry out a
partial water change.
• Filter is incorrectly sized - refer to filter performance and specification
chart.
• The filter foams have not been positioned or replaced correctly,ensure that
the foams fit tightly within the filter chamber.
UVC leaks
• Check that the UVC O-ring have been correctly assembled and that it is
hand tight.
• PTFE tape may be needed to give a water tight seal and should be applied
to the outlet hosetail.
16
Poor Fountain performance
• Reduced height.
DAISY
• Jets blocked.
To clean, remove
head and rinse.
Or in hard water
areas, use Pond
Pump Cleaner.
Clean flow adjuster and fountain
head. Wash under a tap or hose.
ond Pump Cleaner should be used
to remove lime scale build-up/waste
(see diagram) for improved results.
No flow from pump
1. Check power supply is on.
2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION).
3. Follow low flow procedure as above.
If none of the above works contact Interpet (Blagdon) Consumer Advice
Department (See Faults problem procedure Page 20).
17
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 21
TROUBLESHOOTING
IMPORTANT
Green water
FAULTS - PROBLEMS PROCEDURE
• Settlement test the water to ensure that there is no sediment suspended in
the water. If there is, follow the brown cloudy water troubleshooting guide.
Before returning your Inpond to your dealer or contacting our Consumer Advice
Department, please carry out the following steps. This will solve most problems
quickly and easily.
• In order to check that the UVC lamp is operating:
Open the filter unit (see page 10) remove filter foams and cartridge. Then
using a white piece of card against the UVC contact chamber inlet you
should see a faint blue light.
This operation may need to be carried out at dusk as UVC lamps emit a
dim blue light under normal operation. Turning the lamp on and off may
aid visual identification. (Ensure the UVC lamp is not more than 6
months old).
• The UVC may be working effectively but the filter foam/media is too clean
and is unable to remove the fine coagulated waste. Treat the pond with
Clear Pond and do not clean the foams/media until they are blocked.
• The filter is too small for the pond, check your filter selection chart.
• The UVC quartz sleeve is dirty or coated in lime scale. Gently remove the
quartz sleeve and clean.
1. Ensure electrical procedures have been followed fully. Check fuses and
any cable connectors/switch boxes.
2. (a) Follow routine maintenance procedure fully. (b) Check location and
connecting your pump details including flow rates. (c) Ensure that your
pond volume and pump flow rate meet the maximum pond size
recommended for the filter model on the filter performance and
specification chart. (d) Follow troubleshooting guide.
3. If there is a mechanical breakdown of the filter or UVC, return to the
point of purchase for inspection and advice (You will need proof of
purchase).
CLEARWATER GUARANTEE
The Clearwater guarantee will be honoured for 1 year after proof of purchase.
Clearwater is guaranteed to a depth of 1m, so that fish are clearly visible.
Clearwater is guaranteed provided:
•
You follow all instructions as above.
•
Your filter is within the performance guidelines stated.
UVC light not illuminated
•
You consult the Consumer Advice Line and follow any advice to correct
the situation. See details below.
• Check all fuses / RCD and electrical connections follow electrical
installation (pages 11 & 12).
Refunds can only be authorised by Interpet Blagdon.
• Follow all cloudy water trouble shooting points.
CONSUMER ADVICE CONTACT DETAILS
Interpet (Blagdon) Consumer Advice Department
Vincent Lane, Dorking, Surrey RH4 3YX
Telephone: 0845 226 7437
(Monday to Friday 10am to 4pm except Bank Holidays - Times may vary)
Fax: 01306 876712
E-mail: [email protected]
www.blagdonthepondmasters.co.uk
18
19
Blagdon Inpond with UVC AW v2.qxd
22/12/10
14:34
Page 23
GUARANTEE
This product is guaranteed against defects in material and workmanship for 2
years from the date of purchase, under normal usage. The guarantee DOES
NOT APPLY in case of improper use, negligence, lack of maintenance or
accidental damage to either the filter or UVC. If the filter or UVC fails due to a
manufacturing fault within this period it will be either repaired or replaced free
of charge. Liability is limited to replacement of the faulty product only; no
other costs will be reimbursed.
This guarantee is not transferable and does not affect your statutory rights.
This guarantee does not confer any rights other than those expressly set out
above. This guarantee does not cover the filter foams or UVC bulb, which will
need replacing when worn or every 6 months. If any parts are needed, spares
are available from your retailer.
You can help protect the environment.
Please remember to respect the local regulations: hand in the
non-working electrical equipments to an appropriate waste
disposal centre.
20