ACCESSORIES - nihonkohden.de

Transcription

ACCESSORIES - nihonkohden.de
Fighting Disease with Electronics
ACCESSORIES
CARDIOLOGY
2 0 1 3
/
2 0 1 4
2
Introduction
www.nihonkohden.net
Introduction
Dear Customer,
For more than 60 years NIHON KOHDEN has been one of Japan’s leading players in medical technology development and
manufacturing and has subsidiaries and representative offices in Europe, the US, as well as in the Middle and Far East.
“Fighting Disease with Electronics“ – our corporate philosophy – reflects the high standards we have set ourselves in combating
disease by developing medical systems, contributing to higher quality of life for patients.
Our large product range of accessories and consumables is known for its outstanding quality, ease of use and reliability. Please
note, that only the use of original NIHON KOHDEN approved accessories and consumables guarantee optimal examination results
and make an important contribution towards ensuring that your device will continue to function impeccably and reliably even in
years to come, while preserving the device’s features and functional capabilities.
As your partner in cardiology, NIHON KOHDEN provides only tested and approved product solutions from standard vital
signs parameter such as ECG, SpO2 , NIBP or Temperature to specific parameters like Capnography or IBP Measurement. Our
commitment to ensure continually highest quality allows you the best care of your patients and enhances your ECG, AED/TRN and
Defibrillator performances.
NIHON KOHDEN invites you to discover the quality and features of our complete accessories and consumables portfolio in this
catalogue. Call today for more information or order directly!
Best regards,
NIHON KOHDEN EUROPE GmbH
Kristin Baar
Product Manager Accessories & Consumables
3
Content
www.nihonkohden.net
Accessories & Consumables Cardiology
1
User Guide
6
Product Innovation & Smart Cable TM Technology
7
Highest Safety and Quality Standards
8
Quick Guide Electrocardiographs, Defibrillators, AED/TRN
9
ECG Measurement
10
Typical Arrhythmia Waveforms
11
12
1.1
ECG Cables
1.1.1
1.1.2
1.1.3
1.1.4
ECG 10-Lead Cable
ECG 12/15-Lead Cable
ECG Veterinary 5-Lead Cable
Additional Cable Accessories
13
14
15
15
1.2
ECG Electrodes
16
1.2.1
1.2.2
1.2.3
1.2.4
1.2.5
1.2.6
Clip Electrodes
Chest & Plate Electrodes
Tab Electrodes
ECG Electrodes for Adults
ECG Electrodes for Children, Infants & Neonates
ECG Electrode Adapter
17
18
19
20
21
21
1.4
ECG Batteries
22
1.5
ECG Paper
24
1.6
Additional ECG Accessories
27
2
Accessories for Defibrillators
30
2.1
Defibrillator Batteries & Battery Charger
31
2.2
Defibrillator Paper
33
2.3
Defibrillator Bags
35
4
Content
www.nihonkohden.net
2.4
Disposable Defibrillator Pads
37
2.4.1
2.4.2
Disposable Pads with NIHON KOHDEN Connector
Disposable Pads with R2 Connector
38
39
2.5
Paddle Electrodes
40
2.5.1
2.5.2
2.5.3
Internal Paddle Electrode with Discharge Button for Series TEC-8300
Internal Paddle Electrode with Discharge Button for TEC-5500/7700
Neonate Paddle Adapter for TEC-5500/7700
41
42
42
2.6
ECG Measurement
43
Typical Arrhythmia Waveforms
44
2.6.1
ECG Cables
45
2.6.1.1
ECG Cables for TEC-8300
46
2.6.1.1.1
2.6.1.1.2
ECG 3/6-Lead Cables
ECG 10-Lead Cables
47
48
2.6.1.2
ECG Cables for TEC-5500 & TEC-7700
49
2.6.1.2.1 ECG 3-Lead Cables
2.6.1.2.2 ECG 5-Lead Cables
2.6.1.2.3 Further Defibrillator Connection Cables
50
51
52
2.7
ECG Electrodes for Defibrillators
53
2.7.1
2.7.2
ECG Electrodes for Adults
ECG Electrodes for Children, Infants & Neonates
54
55
2.8
SpO2 Measurement
56
2.8.1
SpO2 Cables
57
2.8.2
SpO2 Probes
59
2.8.2.1
2.8.2.2
2.8.2.2.1
2.8.2.2.2
2.8.2.2.3
2.8.2.2.4
Reusable SpO2 Probes
Disposable SpO2 Probes
Disposable SpO2 Probes 24 pcs/box - cable length: 0.8 m
Disposable SpO2 Probes 24 pcs/box - cable length: 1.6 m
Disposable SpO2 Probes 5 pcs/box - cable length: 0.8 m
Disposable SpO2 Probes 5 pcs/box - cable length: 1.6 m
61
63
63
64
64
66
5
2.9
Content
www.nihonkohden.net
ETCO2 Measurement (Capnography)
68
ETCO2 Selection Guide
69
ETCO2 Measurement Overview
70
2.9.1
ETCO2 Mainstream
71
2.9.1.1
2.9.1.2
2.9.1.3
Intubated Expired ETCO2
Intubated Expired and Inspired ETCO2 - “Opening a New Era in Capnography“
Intubated and Non-Intubated Expired ETCO2 CapOne - “Opening a New Era in Capnography“
72
73
74
2.10
Temperature Measurement
76
2.10.1
2.10.2
Standard Temperature Measurement
Measurement of 2 Additional Temperatures
77
77
2.11
NIBP Measurement (Non-invasive Blood Pressure)
78
2.11.1
2.11.2
2.11.3
2.11.3.1
2.11.3.2
NIBP Air Hoses
Reusable NIBP Cuffs - NEW YAWARA CUFF 2
Disposable NIBP Cuffs
Disposable NIBP Cuffs for Infants & Children
Disposable NIBP Cuffs for Adults
79
80
82
82
83
2.12
IBP Measurement (Invasive Blood Pressure)
84
2.12.1
2.12.2
IBP Transducer Cable with Direct Connection
IBP Transducer Cable with Adapter Cable K952
85
86
2.13
Portable CPR
88
2.14
Additional Defibrillator Accessories
90
3
Accessories for AED & Training Unit
92
3.1
3.2
Accessories for AED Units
Accessories for AED Training Unit TRN-2100K
96
96
Accessory Order Form
97
Index as per Supply Code
98
Index as per Model Code
100
6
www.nihonkohden.net
User Guide
User Guide
Care of Environment
NIHON KOHDEN is making every possible effort to ensure that the actions of the company and its employees contribute to
preserving the environment. In order to conserve paper resources, we decided a more environment friendly approach which allows
us to update the catalogue more frequently in the future. Therefore the new accessories and consumables catalogue was designed
for view on your computer. It allows you to zoom pictures in order to see more details of the product. If you need indeed certain
chapters in print version, you can easily select and print them.
Find the right accessories in the catalogue
You do not know exactly which article you need for your examination?
Following this user guide you will find the content of this catalogue which is organized into parameter categories. In a particular
category you will see a list of accessories and consumables with corresponding supply codes, model codes, descriptions and
pictures. If you are not sure if one of the listed products will fit to your requirements, please contact us or one of our regional
representatives.
You already know the article that you need for your examination?
In the index of the catalogue , from page 98 to page 99, the articles are listed alphabetically as per supply code; page 100, the products are
listed alphabetically as per model code. They will help you to find directly the according product page.
If you are using the PDF version, simply use the “search function” of this by entering the description, supply or model code.
Or just click on the related chapter on the left side of the document.
Order information
To order NIHON KOHDEN accessories and consumables or to get more information, please refer to the indicated regional
NIHON KOHDEN representatives below.
For your convenience, we have a printable order form at the end of this catalogue so that you can fax in your order directly or
mail/e-mail it to us. Please make sure to fill out all requested information as well as the required supply code and according
quantity. Please check the general terms and conditions including delivery time, payment and general warranty with your
responsible regional NIHON KOHDEN representatives:
For Germany, Austria, Switzerland and Benelux
NIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland
Albert-Einstein-Ring 9, 14532 Kleinmachnow, Deutschland
Fax: +49 (0) 33203/573-19, E-Mail: [email protected]
For Spain and Portugal
NIHON KOHDEN IBERICA S.L.
C/Ulises, 75A, 28043 Madrid, Spain
Fax: +34 91 300 46 76, E-Mail: [email protected]
For United Kingdom
NIHON KOHDEN UNITED KINGDOM Ltd.
Tolworth Tower – 19th Floor, Ewell Road, Surbiton,
Surrey KT6 7EL, United Kingdom
Fax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]
For France
NIHON KOHDEN FRANCE SARL
8, rue François Delage, 94230 Cachan, France
Fax: +33 (0) 1 49 08 93 32, E-Mail: [email protected]
For Italy
NIHON KOHDEN ITALIA S.r.l.
Via Fratelli Bronzetti, 28, 24124 Bergamo, Italy
Fax: +39 (0) 35-232546, E-Mail: [email protected]
For all other European Countries, Russia, Turkey and Israel
NIHON KOHDEN EUROPE GmbH
Raiffeisenstraße 10, 61191 Rosbach v. d. H., Germany
Fax: +49 (0) 6003/827-599, E-Mail: [email protected]
7
www.nihonkohden.net
Product Innovation & Smart Cable™ Technology
Synthesized 18-lead ECG - Identify Invisible Ischemia A New Technology for More Informative ECG Exam
What is Synthesized ECG ?
Synthesized 18-lead ECG uses the 12-lead ECG waveforms to mathematically derive the waveforms of the right chest leads (V3R, V4R, V5R)
and back leads (V7, V8, V9). The measurement procedure is the same as the standard 12-lead ECG but more information can be obtained.
18-lead synthesized ECG is expected to be useful in detecting right side and posterior infarction.
The most common ECG exam is the standard 12-lead ECG. It is simple to measure, has low burden on the body, and observing the heart
from these 12 directions provides a lot of information which has a wide range of clinical applications.
However, some areas, especially pathological change in the right ventricle and the posterior wall cannot be observed from the
12-lead ECG. In order to actually measure the right chest (V3R, V4R, V5R) and back (V7, V8, V9) areas, it is necessary to use different electrode positions than the standard 12-lead ECG. In particular,
V1
V2 V3
V1
V2 V3
electrodes must also be attached to the patient’s back so that
syn-V3R
normal suction cup electrodes cannot be used. Also, the patisyn-V4R
V4
V4
ent must be turned over in some cases and in an emergency it is
5
V
V5
often difficult to use back electrodes. This complicates the exam prosyn-V
R
5
cedure. Synthesized 18-lead ECG uses the 12-lead ECG waveforms to
V6
V6
mathematically derive the waveforms of the right chest leads (V3R,
V4R, V5R) and back leads (V7, V8, V9).
syn-V7
syn-V8
syn-V9
Standard 12-lead ECG
Synthesized 18-lead ECG
Synthesized right side leads (V3R-V5R) and
synthesized back leads (V7 -V9) are added
NIHON KOHDEN - Smart Cable™ Technology
A Cost-Effective Solution to Modular Monitoring
With NIHON KOHDEN Smart Cable Technology, you will get complete modular flexibility at a significantly reduced cost and without all of the inconvenience associated with traditional modular systems. Smart CableTM
technology miniaturizes circuits found in traditional modules and embeds that circuitry into the cable. When you plug a Smart CableTM into
a MULTI connector, it automatically detects the type of parameter and
starts measuring.
Smart Connector Technology is available for the following parameters:
= Available
– = N/A
Defibrillator
Patient Monitors
Version 08/2013; Subject to
change without notice
Parameter
Current Products
Older Products
Series TEC-8300
BSM-1700
PVM-2700
BSM-3000
BSM-6000
BSM-9100
BSM-2300
initial SW
initial SW
SW-V.03-30
SW V.04-12
SW V.04-12
SW-V.13-05
SW V.04-31
Flo Trac (APCO)
–
–
–
BISx Bispectral Index
–
BISx remarks
–
with YJ-671P
Dual SpO₂ (Second SpO2)
IBP (Invasive Blood Pressure)
CO (Cardiac Output)
–
–
–
–
–
–
only PVM-2703
–
–
EtCO₂ (Capnography)
–
with PVM-2703
–
–
with YJ-671P
with YJ-230P
via JA-69xP (DAU)
via AUX port only
via JA-69xP (DAU)
–
–
–
–
RESP (Respiration)
–
–
–
–
–
FiO₂ (Fraction of inspired oxygen)
–
–
–
–
–
TEMP (Temperature)
8
Highest Safety and Quality Standards
www.nihonkohden.net
Highest Safety and Quality Standards
Comprehensive quality assurance systems ensure that each of the more than 4,000 NIHON KOHDEN staff members
makes his/her contribution towards development, manufacture, marketing and customer services such that
maximum product quality is guaranteed.
NIHON KOHDEN is certified according to ISO 9001, ISO 13485 and ISO 14001.
NIHON KOHDEN designs and manufactures medical equipment in conformity with the standards of IEC 60601-1
(Medical Electrical Equipment: General Requirements for Safety).
NIHON KOHDEN products have earned a reputation for quality and long life. One reason is that all export products
and major components are manufactured in our own ISO 9001 and IEC 13485 certified factories.
In 1984, NIHON KOHDEN implemented a comprehensive companywide quality system, IQC – Integrated Quality
Control. Under this system, quality begins at the earliest stage of every product’s life. Our IQC applies to the entire
manufacturing process, from the planning stage through product development, design, parts procurement,
production, inspection, storage, sales, distribution and after-sales support. IQC also involves nearly every employee.
Our rigid test procedures are structured to exceed the provisions of the GMP, Good Manufacturing Practice, codes
enforced by the US Food and Drug Administration. NIHON KOHDEN also has 130 in-house quality control inspection
staff to ensure that standards are implemented and maintained in every department of the company.
IQC extends beyond production and into sales and support at each subsidiary. This staff is responsible for ongoing
contact with customers to determine their needs and making sure that these changing requirements are reflected
in new products. Service engineers are responsible for communicating any problem that may arise in the use of
NIHON KOHDEN products, and assuring the customers of NIHON KOHDEN’s commitment to their satisfaction.
In 1995, NIHON KOHDEN received ISO 9001 certification, the international standard for quality systems. In addition,
NIHON KOHDEN’s four manufacturing facilities in Japan are the first factories in the medical equipment industry to
be certified by the CSA, Canadian Standards Association, under their category certification system. Most products
sent to North America carry the CSA label.
Quality improvement is and always has been an ongoing process for NIHON KOHDEN.
Convince yourself of our expertise and the high quality of our products and services! Order directly!
9
www.nihonkohden.net
Quick Guide NIHON KOHDEN
Quick Guide
ECG-2350
ECG-2550
ECG-1500/1550
ECG-1150
ECG-1250
ECG-1350
ECG-1950
ECG-9620
ECG-9320
ECG-9130/9132
ECG-9110
ECG-9020/9022
ECG-9010
ECG-8830
ECG-8820/8823
ECG-8420/8450
ECG-8350/8370
ECG-8330/8340
ECG-8240/8270
ECG-8110
TEC-7511/7521/7531
TEC-7100/7200/7300
TEC-8321/8322/8332/
8342/8352
TEC-5521/5531
TEC-6100
TEC-2202/2203
AED-2100
AED-2150/2151/2152
ECG-6851
TEC-7721/7731
TEC-7621/7631
TRN-2100
TRN-2150
AED/TRN
DEFIBRILLATORS
ELECTROCARDIOGRAPHS
Electrocardiographs, Defibrillators, AED/TRN
ECG Measurement
Highly accurate ec1 arrhythmia analysis
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.
Number of false alarms
3000
2500
V. Rhythm
Tachy
2000
VPC Run
1500
VT
Ext. Tachy
1000
VF
500
0
Without ec1
With ec1
Cardiology › Typical Arrhythmia Waveforms
11
www.nihonkohden.net
Typical Arrhythmia Waveforms
Premature Supraventricular Contractions
(Premature Atrial Contractions (PAC))
P
P
• Narrow QRS (excluding aberrant ventriular conduction)
• Ectopic focus higher than His-bundle • Non-compensatory pause
Premature Ventricular Contractions (PVC)
• Premature contractions • Bizarre and wide QRS complexes
• Full compensatory pause • Frequent PVCs are serious
Multi- focal PVC
1
Atrial Fibrillation (AF)
• Slight ripples on the baseline • Irregular R-R intervals
• Inverted QRS complexes • Non-compensatory pause
Ventricular Tachycardia (VT)
• Fast pulse rate greater than 100 bpm • 3 or more irregular beats
• Needs emergency treatment and countershock • May progress to
Ventricular Fibrillation (VF)
2
• Multi form PVCs • Bizarre and wide QRS complexes
• No discernable P-waves, R-waves, P-R rythm or QRS complexes
• Needs emergency treatment and countershock
Second-degree atrioventricular (AV) block, Mobitz type II
Short run PVC
P
• Consecutive PVCs • May progress to ventricular tachycardia
P
P
• Sudden absence of QRS complexes (P-waves observed) • May progress
to cardiac arrest • Possibillity of Adams-Stokes syndrome
• Occasionally needs pacing
Third-degree (complete) atrioventricular (AV) block
R-on-T PVC
P
• PVC on summit of T-wave • Bizarre and wide QRS complexes
P P
P
P P
P
P
P
P
P
• Independent development of P-waves and QRS complexes • Possibility
of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing
Nihon Kohden products
which detect arrhythmia
Electrocardiographs / Defillibrators / Bedside Monitors
Diagnostic ECG Electrode Placement
Heart Anatomy
Cardiac Conduction Sytem
same horizontal level as C4 and C5
--------------------------
-------------------
--------------------------
-------------
-------------------
-------------
1. Inferior vena cava
1 The sinoatrial (SA) node generates
R and L electrodes should be placed just below
Atria His bundle
SA node
a wave of electrical excitation.
2. Superior vena cava
the right and left clavicle. N and F electrodes should
2
1
Left
2 The excitation travels through
17
15
3. Right atrium
16
2
be placed on the lower edge of the rib cage, or at
bundle
the internodal pathways to the
4. Tricuspid valve
3
2
branch
the level of the umbilicus at the mid-clavicular line.
AV node
atria and the atrial muscles contract.
5. Right ventricle
7
Purkinje This is recorded as the P-wave.
7
4
6.
Pulmonary
valve
8
fibers 3 The excitation travels to the
14
Right
5
7. Pulmonary artery
bundle
Lead Electrode Placement
atrioventricular (AV) node.
branch
9
8. Pulmonary vein
5
C1
Fourth intercostal space at the
13
4 The excitation then travels through
8 9. Left atrium
right border of the sternum
Purkinje
the bundle of His and down through
10
Ventricles
3 7
10. Mitral valve
fibers
Fourth intercostal space at the
R
L
C2
the right and left bundle branches.
12
11.
Left
ventricle
R
11
right border of the sternum
6
5 The excitation terminates at the
12. Aortic valve
Purkinje fibers in the ventricles and
Midway between locations C2
C3
T
13. Coronary artery
P
the ventricular muscles contract. This
1 4
and C4
C1 C2
5
14. Aorta
C3 C6
is the depolarization and is recorded
At
the
mid-clavicular
line
in
the
C4
C4 C5
15. Brachiocephalic artery
as the QRS complex.
Q S
1
fifth intercostal
space
Disposable accessories are intended for single use only, on one patient, during
Do not re-use
disposable accessories!
16. Left common
carotid artery
6 The ventricular muscles relax. This is
2
18 a single examination!
3.4
At the anterior axillary line on the
C5
17. examinations.
Left subclavian artery
the repolarization
Reusable accessories are intendedNfor repeated patient
use on different patients during different
Please make sure to clean reusable accessories
after each
patient or and is recorded as
F
5
same horizontal level as C4
the T- wave.
18. Descending aorta
between different applications to prevent or reduce the risk of cross infections!
6
C6
At the mid-axillary line on the
ECG Cables
ECG 10-Lead Cable
ECG 12/15-Lead Cable
ECG Veterinary 5-Lead Cable
Additional Cable Accessories
13
Electrocardiographs > ECG Cables
www.nihonkohden.net
ECG 10-Lead Cable
Supply Code
Model
Description
K081
BJ-902D
10-Lead ECG Patient Cable, 4 mm banana plug (IEC), limb 3.4 m/chest 2.9 m
For current products: ECG-1150/1250/1350/2350
Packing unit: 1 pcs
K082
BJ-903D
10-Lead ECG Patient Cable, snap (IEC), limb 3.4 m/chest 2.9 m
For current products: ECG-1150/1250/1350/2350
Packing unit: 1 pcs
K079
BJ-901D
10-Lead ECG Patient Cable, 3 mm banana plug (IEC), limb 1.2 m/chest 0.7 m
For current products: ECG-1150/1250/1350/2350
Packing unit: 1 pcs
K093C
BR-912D
10-Lead ECG Patient Cable, 4 mm banana plug (IEC), for input-box JC-901D,
for resting ECG, limb 1.2 m/chest 0.7 m
For current products: ECG-1550
Packing unit: 1 pcs
K093D
BR-913D
10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for resting ECG,
limb 1.2 m/chest 0.7 m
For current products: ECG-1550
Packing unit: 1 pcs
K093F
BR-913E
10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for stress test,
limb/chest 0.6 m
For current products: ECG-1550
Packing unit: 1 pcs
K096A
490933
Connection Cable for Patient Input-Box JC-901D, cable length: 2.0 m
For current products: ECG-1550
Packing unit: 1 pcs
K096B
669269
Connection Cable for Patient Input-Box JC-901D, cable length: 5.0 m
For current products: ECG-1550
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
14
Electrocardiographs > ECG Cables
www.nihonkohden.net
ECG 12/15-Lead Cable
Supply Code
Model
Description
K093L
BR-921D
15-Lead ECG Patient Cable, 3 mm banana plug (IEC), for input-box JC-901D,
for stress test, limb/chest 1.2 m
For current products: ECG-1550
Packing unit: 1 pcs
KB010
BR-202D
12-Lead Set (Electrode Leads: R,L,F,N,C1,C2,C3,C4,C5,C6), 4 mm banana plug
For current products: ECG-2550
Packing unit: 1 pcs
KB012
BR-202D
XYZ-Lead Set, 4 mm banana plug
For current products: ECG-2550
Packing unit: 1 pcs
K118
Slide Clipper for Chest
For current products: ECG-2550
Packing unit: 1 pcs
K119
Slide Clipper for Limb
For current products: ECG-2550
Packing unit: 1 pcs
Supply Code
Model
Chest Lead
Label Color
KB01A
KB02A
KB03A
KB04A
KB05A
KB06A
KB07A
KB08A
KB09A
KB10C
KB11C
KB12D
KB13B
KB13D
KB14B
KB15B
KB16B
KB17B
KB18B
KB19C
BR-202D
BR-202D
BR-202D
BR-202D
BR-202D
BR-202D
BR-202D
BR-202D
BR-202D
C1
C2
C3
C4
C5
C6
CX1
CX2
CX3
red
yellow
green
brown
black
violet
Cable Length
Cable Color
0.7 m
white
1.2 m
grey
For current
products
Packing unit
white
red
yellow
green
black
yellow
red
blue
orange
brown
white
ECG-2550
1 pcs
1.4 m
1.0 m
1.4 m
1.0 m
white
1.2 m
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
15
Electrocardiographs > ECG Cables
www.nihonkohden.net
ECG Veterinary 5-Lead Cable
Supply Code
Model
Description
K098
BJ-904D
5-Lead Veterinary ECG Connection Cable, 3 mm banana plug (IEC)
For current products: ECG-1950
Packing unit: 1 pcs
Additional Cable Accessories
Supply Code
Model
Description
K097
BM-901D
Adapter for ECG Vacuum Equipment with 15 PIN Sub-D Connector to
input-box JC-901D
For current products: ECG-1500/1550
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Electrodes
Standard Electrodes Placements
It is important to prepare the skin before attaching the electrodes
by cleaning it and removing chest hair. After this please attach
the lead wire to the electrodes before placing them on the skin.
This avoids pain to the patient. Secure the lead wire to the skin
(stress loop) preventing moving of the lead wire and therefore
noise on the ECG signal.
Three electrodes
Ten electrodes
Clip Electrodes
Chest & Plate Electrodes
Tab Electrodes
ECG Electrodes for Adults,
Children, Infants & Neonates
ECG Electrode Adapter
Electrocardiographs > ECG Electrodes
17
www.nihonkohden.net
Clip Electrodes
Facts
The NIHON KOHDEN Fastclip ECG Electrodes allow a flexible application for routine work and emergency on every paediatric and adult
patient thanks to a simple adjustability of the clip pressure (clip size). A more comfortable handling is guaranteed due to different con-nectors for any
existing adapter type, a big contact area for reliable ECG measurements and easier cleaning after the measurement because of less asperity of the clip.
In addition to this IEC colored label sets are delivered with NIHON KOHDEN Fastclip ECG Electrodes.
By following the next steps, optimized derivations can be realized with NIHON KOHDEN Fastclip ECG Electrodes:
1.) Clean the according skin areas with alcohol in order to remove traces of dirt and oil on the skin.
2.) Apply a thin layer of CardioCream F010 on the cleaned skin areas and on the electrode part.
3.) Clip the electrode on the wrist or ankle. Adjust the electrode positon by sliding the electrode part according to the thickness of the limb.
Adjustability
strong
Easy to handle
middle
weak
wide
narrow
spring
Contact pressure and position of electrodes section can be adjusted according to patients΄ conditions.
Opens more widly*, and round
form brings easy to grip.
(*compared to the previous model)
Three types of connectors available
Easy cleaning
Raised dots
Trench shape
Tip
Clip
Snap
Any of tip, clip and snap type connector
is available.
Supply Code
Description
H068A
Fastclip ECG Electrode, 3 mm, child/adult, blue, adjustable size
For current products: all ECG/EEG
Packing unit: 4 pcs
H068B
Fastclip ECG Electrode, 4 mm, child/adult, blue, adjustable size
For current products: all ECG/EEG
Packing unit: 4 pcs
H072
Veterinary Clip Electrode, 3 mm, cable length: 0.3 m, for K098
For current products: ECG-1950/9022
Packing unit: 5 pcs
Previous model
New model
Less asperity easy cleaning.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
18
Electrocardiographs > ECG Electrodes
www.nihonkohden.net
Chest & Plate Electrodes
Supply Code
Model
Description
H041A
6144-000427
Chest Suction Electrode, 3 mm, adult, size: 20 mm dia, grey rubber ball
Packing unit: 3 pcs
H043A
6144-011852
Chest Suction Electrode, 4 mm, adult, size: 20 mm dia, grey rubber ball
Packing unit: 3 pcs
H044A
NC-124D
Chest Suction Electrode Tako, 4 mm, child, size: 14 mm dia, pink octopus
rubber ball
Packing unit: 3 pcs
H044B
NC-124D
Chest Suction Electrode Kuma, 4 mm, child, size: 14 mm dia, blue bear
rubber ball
Packing unit: 3 pcs
H049
Grey Rubber Ball Set for Adult Suction Electrode H043A
Packing unit: 3 pcs
H052A
Pink Octopus Rubber Ball Set for Children Suction Electrode H044A
Packing unit: 3 pcs
H052B
Blue Bear Rubber Ball Set for Children Suction Electrode H044B
Packing unit: 3 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
19
Electrocardiographs > ECG Electrodes
Supply Code
Description
NKD-Z715
Plate Electrode, adult, size: 30 mm dia, suitable limb electrode straps, for NKD-Z722
Packing unit: 1 pcs
NKD-Z722
Rubber Strap, chest, size: 135 cm x 7 cm, black, 5 rows of holes, for plate electrode
NKD-Z715
Packing unit: 1 pcs
NKD-Z723
Attachment Button for Rubber Strap NKD-Z722
Packing unit: 1 pcs
www.nihonkohden.net
Tab Electrodes
Supply Code
Description
NKD-ECG/TAB1
ECG Tab Electrode Normal, Ag/AgCl, child/adult, radiolucent (X-ray, MRI),
size: 26 x 34 mm, bio-solid gel, backing material: graphite, for resting ECG
Packing unit: 500 pcs
NKD-ECG/TAB2
ECG Tab Electrode Small, Ag/AgCl, child, radiolucent (X-ray, MRI), size: 13 x 34 mm,
bio-solid gel, backing material: graphite, for resting ECG
Packing unit: 500 pcs
NKD-H/ADAPTER2
ECG Tab Electrode Clamps for NKD-ECG/TAB1 & NKD-ECG/TAB2, 4 mm banana plug
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
20
Electrocardiographs > ECG Electrodes
www.nihonkohden.net
ECG Electrodes for Adults
NIHON KOHDEN VITRODE Disposable ECG Electrodes –
The result of over 30 years experience in disposable electrode manufacturing.
The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that the electrical
signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an extended period of time (over
48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause “noisy’’ ECG signals because of
the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting capabilities intermittently, and this leads
to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is to change these electrodes at least every 48 hours.
Please contact us for individual offer based on your annual volume! Use the possibility of call orders!
Supply Code
Model
Description
G203
L-150
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape,
solid gel, general use
Packing unit: 5 x 30 pcs
G204
C-150
ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony
softcloth with an elastic quality for tension, solid gel
Packing unit: 5 x 30 pcs
G207
L-150X
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray),
foam tape, solid gel
Packing unit: 5 x 30 pcs
G210D
F-150M
ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially
for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
G236
M-150
ECG Electrode Vitrode M, Ag/AgCl, child/adult, size: 40 mm dia, foam tape,
highbrid gel, for stress test
Packing unit: 5 x 30 pcs
G250
J-150
ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel,
excellent adhesion even on sweaty skin
Packing unit: 5 x 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
21
Electrocardiographs > ECG Electrodes
www.nihonkohden.net
ECG Electrodes for Children, Infants & Neonates
Supply Code
Model
Description
G210C
F-150S
ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm,
cotton tape especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
ECG Electrode Adapter
Supply Code
Description
N-00
Snap Adapter for Disposable ECG Electrodes, 4 mm dia plug to clip connector
Packing unit: 5 pcs
N-08
Clip Adapter for Disposable ECG Electrodes, 4 mm dia plug to snap connector
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Batteries
23
Electrocardiographs > ECG Batteries
www.nihonkohden.net
ECG Batteries
Supply Code
Model
Description
X065
NKB-301V
Battery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-1350/2350/TEC-5500/7700
Packing unit: 1 pcs
X071
SB-901D
Battery Pack, 12V, 1950 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-1150/1250/1950
Packing unit: 1 pcs
X073
SB-150D
Battery Pack, 12V, 3600 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-1500/1550
Packing unit: 1 pcs
X078
SB-201D
Battery Pack, 14.4V, 3400 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-2550
Packing unit: 1 pcs
X040
LCS-2012NK
Battery Pack, 12V, 2000 mAh, lead-acid, rechargeable
For old products: ECG-6000/OEC-8110
Packing unit: 1 pcs
X041A
LCT-1912ANK
Battery Pack, 12V, 1900 mAh, lead-acid, rechargeable
For old products: ECG-9022/9132
Packing unit: 1 pcs
X041B
LC-S2912NK
Battery Pack, 12V, 2900 mAh, lead-acid, rechargeable
For old products: ECG-9320/TEC-7500
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Paper
25
Electrocardiographs > ECG Paper
www.nihonkohden.net
ECG Paper
Supply Code
Model
Description
A052
FQW210-10-295
Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages,
with queue mark/perforation
For old products: ECG-9320
Packing unit: 10 pcs
A053
FQW210-30-295
Thermal Paper, Z-fold, 210 mm x 300 m (page 295 mm), 1017 pages,
without grid, with queue mark/perforation
For current products: ECG-2550/1550 | For old products: ECG-9320
Packing unit: 1 pcs
A128
RQS50-3
Thermal Paper, roll, 50 mm x 30 m, orange grid
For current products: TEC-8300
For old products: ECG-6651/TEC-7100/7200/7300
Packing unit: 10 pcs
A129
RQS63-3
Thermal Paper, roll, 63 mm x 30 m, with grid, without queue
mark/perforation
For old products: ECG-1150
Packing unit: 10 pcs
NKD-210-10/295
Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages,
without grid, with queue mark/perforation, equivalent to
A052 & NKD-210-10A
For old products: ECG-9320/old MEB
Packing unit: 10 pcs
NKD-210-5-295
Thermal Paper, Z-fold, 210 mm x 50 m (page 295 mm), 169 pages,
without grid, equivalent to A053
For current products: ECG-2550/1550 | For old products: ECG-9320
Packing unit: 10 pcs
NKD-A054
Thermal Paper, Z-fold, 210 mm x 30 m (page 140 mm), 214 pages,
without grid, with queue mark/perforation
For current products: ECG-1350/2350 | For old products: ECG-9132
Packing unit: 10 pcs
NKD-A730
Thermal Paper, Z-fold, 110 mm x 20 m (page 140 mm), 143 pages,
without grid, with queue mark/perforation
For current products: ECG-1250/1950 | For old products: ECG-9022
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
26
Electrocardiographs > ECG Paper
Supply Code
Description
NKD-63
Thermal Paper, Z-fold, 63 mm x 30 m (page 75 mm), 400 pages, with grid,
without queue mark/perforation
For old products: ECG-9620
Packing unit: 10 pcs
NKD-A129
Thermal Paper, roll, 63 mm x 30 m, with grid, without queue mark/perforation,
equivalent to A129
For current products: ECG-1150 | For old products: ECG-9620
Packing unit: 10 pcs
NKD-145-2,5
Thermal Paper, Z-fold, 145 mm x 25 m (page 100 mm), 85 pages, orange grid,
equivalent to A036B
For old products: ECG-8400
Packing unit: 10 pcs
NKD-145-6A300
Thermal Paper, roll, 145 mm x 60 m (page 300 mm), 200 pages, orange grid,
equivalent to A132 but without queue mark/perforation
For old products: ECG-8821
Packing unit: 10 pcs
NKD-A134A
Thermal Paper, roll, 210 mm x 30 m, without grid/queue mark/perforation
For old products: ECG-9110/9130/9132
Packing unit: 10 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Additional ECG Accessories
28
Electrocardiographs > Additional ECG Accessories
www.nihonkohden.net
Additional ECG Accessories
Supply Code
Model
Description
F010
Z-101BC
“CardioCream” ECG Electrode Paste, 100 g tube
Packing unit: 2 pcs
NKD-G711
Electrode Spray Gyrolux, skin preparation for use of suction vacuum pumps,
250 ml bottle
Packing unit: 1 pcs
NKD-SD1GB
Memory SD Card 1 GB
Packing unit: 1 pcs
Y011
404617
Thermal Head Cleaner Pen
For current products: all ECG/TEC/old MEB/EEG/allBSM/PVM/OPV/WEP
Packing unit: 1 pcs
NKD-BAG
Carrying Bag for ECG & Accessories
For current products: ECG-1150/1250/1350/1950/2350
Packing unit: 1 pcs
NKD-L936
Power Cable, Schuko plug, cable length: 2.0 m
Packing unit: 1 pcs
NKD-POWERLINE
Multiple Power Socket (4 slots), medical certification
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
29
Electrocardiographs > Additional ECG Accessories
Supply Code
Description
K117A
Connection Cable for Input Box, cable length: 2.0 m
For current products: ECG-2550
Packing unit: 1 pcs
K117B
Connection Cable for Input Box, cable length: 5.0 m
For current products: ECG-2550
Packing unit: 1 pcs
K117C
Connection Cable for Input Box, cable length: 10.0 m
For current products: ECG-2550
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Accessories for Defibrillators
Defibrillator Batteries & Battery Charger
32
Defibrillators > Defibrillator Batteries & Battery Charger
www.nihonkohden.net
Defibrillator Batteries & Battery Charger
Supply Code
Model
Description
X065
NKB-301V
Battery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: TEC-5500/7700/ECG-1350
Packing unit: 1 pcs
X077
SB-831V
Battery Pack, 14.4V, 6300 mAh, lithium-ion battery, rechargeable
For current products: TEC-8300
Packing unit: 1 pcs
X041
LCT-1912NK-1 Battery Pack, 12V, 1900 mAh, lead-acid, rechargeable
For old products: TEC-7100/7200
Packing unit: 1 pcs
X041B
LC-S2912NK
Battery Pack, 12V, 2900 mAh, lead-acid, rechargeable
For old products: ECG-9320/TEC-7500
Packing unit: 1 pcs
X060A
NKB-102V
Battery Pack, 12V, 1700 mAh, nickel-cadmium (NiCd), rechargeable
For old products: TEC-8200
Packing unit: 1 pcs
SB-801V
External Dual Battery Charger, for 2x battery X077
For current products: TEC-8300
Packing unit: 1 pcs
SC-831V
AC/DC Module for Series TEC-8300K
For current products: TEC-8300
Packing unit: 1 pcs
SB-551V
External Dual Battery Charger, for 2x battery X065
For current products: TEC-5500/7700
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Defibrillator Paper
34
Defibrillators > Defibrillator Paper
www.nihonkohden.net
Defibrillator Paper
Supply Code
Model
Description
A128
RQS50-3
Thermal Paper, roll, 50 mm x 30 m, orange grid
For current products: TEC-8300 | For old products: ECG-6651/TEC-7100/7200/7300
Packing unit: 10 pcs
A222
FQS50-3-100
Thermal Paper, Z-fold, 50 mm x 30 m (page 100 mm), 300 pages, orange grid
For current products: TEC-7700
Packing unit: 10 pcs
A226
FQS50-2-100
Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange grid
For current products: TEC-5500/BSM-2300/3000
Packing unit: 10 pcs
A238
PS50-2
Thermal Paper, roll, 50 mm x 20 m, orange grid, without queue mark/perforation
For old products: TEC-6600
Packing unit: 10 pcs
NKD-A226
Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange grid
For current products: TEC-5500
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Defibrillator Bags
36
Defibrillators > Defibrillator Bags
www.nihonkohden.net
Defibrillator Bags
Supply Code
Description
NKD-DEFIBAG83
Softbag for Series TEC-8300K incl. Warning Sign Label
Please indicate the specified abbreviation letter for the required language when
ordering: English (K), German (G), French (F), Italian (R), Spanish (E), Turkish (TR)
or Russian (RU)!
For current products: TEC-8300
Packing unit: 1 pcs
NKD-STRAP83
Shoulder Strap for Series TEC-8300K Softbag
For current products: TEC-8300
Packing unit: 1 pcs
NKD-DEFIBAG2
Carrying Bag 2 with 2 Additional Attached Accessory Bags
For current products: TEC-7700
Packing unit: 1 pcs
NKD-DEFIBAG3
Carrying Bag 3 with 1 Additional Attached Accessory Bag
For current products: TEC-5500
Packing unit: 1 pcs
NKD-DEFIBAG6
Accessory Bag
For current products: TEC-5500/7700
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Disposable Defibrillator Pads
Disposable Pads with
NIHON KOHDEN Connector
Disposable Pads with
R2 Connector
38
Defibrillators > Disposable Defibrillator Pads
www.nihonkohden.net
Disposable Pads with NIHON KOHDEN Connector
Supply Code
Model
Description
H312
P-513
Defibrillation Pads with Outside Connector, infant (< 10 kg), for use with adapter
cable JC-765V/K342B, weight: 80 g ± 10 g, size: 73 mm ± 8 mm x 110 mm ± 11 mm,
conductive surface: 48.40 cm2 ± 10%, cable length: 1.5 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair
H327
P-511
Defibrillation Pads with Outside Connector, child/adult (> 10 kg), for use with
adapter cable JC-765V/K342B, weight: 90 g ± 15 g, size: 108 mm ± 10 mm x 159 mm ±
10 mm, conductive surface: 99 cm2 ± 10%, cable length: 1.5 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair
K342B
JC-865V
Adapter Cable for Disposable Defibrillator Pads H312/H327/H324A,
cable length: 3.5 m
For current products: TEC-8300
Packing unit: 1 pcs
JC-765V
Y206A
Adapter Cable for Disposable Pads H312/H327/H324A, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs
AX-250V
AED Cable Testing Unit for NIHON KOHDEN-Pads with
Adapter Cable JC-765V/K342B
For current products: TEC-5500/7700/8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
39
Defibrillators > Disposable Defibrillator Pads
www.nihonkohden.net
Disposable Pads with R2 Connector
Supply Code
Model
Description
NKD-H405
Defibrillator Pads with Outside R2 Connector, adult, for use with adapter cable
JC-755V/K342A, size: 159.93 cm², conductive surface: 114.75 cm²,
cable length: 1.28 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair
NKD-H406
Defibrillator Pads with Outside R2 Connector, child, for use with adapter cable
JC-755V/K342A, size: 78.13 cm², conductive surface: 53.80 cm², cable length: 1.28 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair
K342A
JC-855V
JC-755V
Y206B
Adapter Cable for Disposable Defibrillator Pads NKD-H405/NKD-H406
with R2 Connector, cable length: 3.5 m
For current products: TEC-8300
Packing unit: 1 pcs
Adapter Cable for Disposable Defibrillator Pads NKD-H405/NKD-H406
with R2 Connector, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs
AX-251V
AED Cable Testing Unit for R2 Pads with Adapter Cable JC-755V/K342A
For current products: TEC-5500/7700/8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Paddle Electrodes
Internal Paddle Electrode
Neonate Paddle Adapter
41
Defibrillators > Paddle Electrodes
www.nihonkohden.net
Internal Paddle Electrode with Discharge Button
for Series TEC-8300
Supply Code
Description
ND-893V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 35 mm dia
For current products: TEC-8300
Packing unit: 1 pair
ND-894V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 45 mm dia
For current products: TEC-8300
Packing unit: 1 pair
ND-895V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 55 mm dia
For current products: TEC-8300
Packing unit: 1 pair
ND-896V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 65 mm dia
For current products: TEC-8300
Packing unit: 1 pair
ND-897V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 75 mm dia
For current products: TEC-8300
Packing unit: 1 pair
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
42
Defibrillators > Disposable Defibrillator Pads
www.nihonkohden.net
Internal Paddle Electrode with Discharge Button
for TEC-5500/7700
Supply Code
Description
ND-593V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 35 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair
ND-594V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 45 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair
ND-595V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 55 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair
ND-596V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 65 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair
ND-597V
Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 75 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair
Neonate Paddle Adapter for TEC-5500/7700
Supply Code
Description
ND-612V
Paddle Adapter, neonate, size: 44 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Measurement
Highly accurate ec1 arrhythmia analysis
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.
Some functions are limited on series TEC-8300K. Contact your NIHON KOHDEN representative for details.
Number of false alarms
3000
2500
V. Rhythm
Tachy
2000
VPC Run
1500
VT
Ext. Tachy
1000
VF
500
0
Without ec1
With ec1
44
www.nihonkohden.net
Cardiology › Typical Arrhythmia Waveforms
Typical Arrhythmia Waveforms
Premature Supraventricular Contractions
(Premature Atrial Contractions (PAC))
P
P
• Narrow QRS (excluding aberrant ventriular conduction)
• Ectopic focus higher than His-bundle • Non-compensatory pause
Premature Ventricular Contractions (PVC)
• Premature contractions • Bizarre and wide QRS complexes
• Full compensatory pause • Frequent PVCs are serious
Multi- focal PVC
1
Atrial Fibrillation (AF)
• Slight ripples on the baseline • Irregular R-R intervals
• Inverted QRS complexes • Non-compensatory pause
Ventricular Tachycardia (VT)
• Fast pulse rate greater than 100 bpm • 3 or more irregular beats
• Needs emergency treatment and countershock • May progress to
Ventricular Fibrillation (VF)
2
• Multi form PVCs • Bizarre and wide QRS complexes
• No discernable P-waves, R-waves, P-R rythm or QRS complexes
• Needs emergency treatment and countershock
Second-degree atrioventricular (AV) block, Mobitz type II
Short run PVC
P
• Consecutive PVCs • May progress to ventricular tachycardia
P
P
• Sudden absence of QRS complexes (P-waves observed) • May progress
to cardiac arrest • Possibillity of Adams-Stokes syndrome
• Occasionally needs pacing
Third-degree (complete) atrioventricular (AV) block
R-on-T PVC
P
• PVC on summit of T-wave • Bizarre and wide QRS complexes
P P
P
P P
P
P
P
P
P
• Independent development of P-waves and QRS complexes • Possibility
of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing
Nihon Kohden products
which detect arrhythmia
Electrocardiographs / Defillibrators / Bedside Monitors
Diagnostic ECG Electrode Placement
Heart Anatomy
Cardiac Conduction Sytem
1. Inferior vena cava
1 The sinoatrial (SA) node generates
Atria His bundle
SA node
a wave of electrical excitation.
2. Superior vena cava
2
1
Left
2 The excitation travels through
15 16 17
3. Right atrium
2
bundle
the internodal pathways to the
4. Tricuspid valve
3
2
branch
AV node
atria and the atrial muscles contract.
5. Right ventricle
7
Purkinje This is recorded as the P-wave.
7
4
6. Pulmonary valve
8
fibers
14
Right
3 The excitation travels to the
5
7. Pulmonary artery
bundle
Electrode Placement
atrioventricular (AV) node.
branch
9
8.
Pulmonary
vein
5
Fourth intercostal space at the
13
4 The excitation then travels through
8 9. Left atrium
right border of the sternum
Purkinje
the bundle of His and down through
10
Ventricles
3 7
10. Mitral valve
fibers
Fourth intercostal space at the
R
L
the right and left bundle branches.
12
11.
Left
ventricle
R
11
right border of the sternum
6
5 The excitation terminates at the
12. Aortic valve
Purkinje fibers in the ventricles and
Midway between locations C2
T
13. Coronary artery
P
the ventricular muscles contract. This
1 4
and C4
C1 C2
5
14. Aorta
C3 C6
is the depolarization and is recorded
At the mid-clavicular line in the
C5
C4
15. Brachiocephalic artery
as the QRS complex.
Q S
1
fifth intercostal space
16. LeftDo
common
carotiddisposable
artery
Disposable accessories are intended for single use only, on one patient, during
not re-use
accessories!
6 The ventricular muscles relax. This is
2
18 a single examination!
3.4
At the anterior axillary line on the
17. examinations.
Left subclavian artery
the repolarization and is recorded as
use on different patients during different
Please make sure to clean reusable accessories
F
5 after each patient or
sameReusable
horizontalaccessories
level as C4 are intended Nfor repeated patient
the T- wave.
18. Descending aorta
between different applications to prevent or reduce the risk of cross infections!
6
At the mid-axillary line on the
C5
C6
same horizontal level as C4 and C5
--------------------------
C4
-------------------
C3
--------------------------
C2
-------------
C1
-------------------
Lead
-------------
R and L electrodes should be placed just below
the right and left clavicle. N and F electrodes should
be placed on the lower edge of the rib cage, or at
the level of the umbilicus at the mid-clavicular line.
ECG Cables
ECG Cables for TEC-8300
ECG 3/6-Lead Cables
ECG 10-Lead Cables
47
Defibrillators > ECG Measurement
www.nihonkohden.net
ECG 3/6-Lead Cables
6-lead ECG measurement
V4 V5
Powerful ECG measurement
96 % of an ischaemia change can be
detected by 6 electrodes (II, V4, V5)
ST Change Detection Report
• Only with I lead symbol 33%
• Only with V5 lead symbol 75%
Supply Code
6124-039432
Model
K120
NA-0003
Electrode Lead Tube for K911/K910A
For current products: TEC-8300/5500/7700/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 5 pcs
K910A
BR-913P
3-Lead ECG Electrode Cable, clip, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-8300/5500/7700/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
K911
BR-903P
3-Lead ECG Electrode Cable, snap, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-8300/5500/7700/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
K913A
BR-906V
6-Lead ECG Electrode Cable, clip, cable length: 0.6 m
For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;
ZM-920/930/940PG
Packing unit: 1 pcs
K912
BR-906P
6-Lead ECG Electrode Cable, clip, cable length: 0.8m requires K922
For current products: TEC-8300/all BSM/PVM; ZM-920/930/940PG
Packing unit: 1 pcs
• II + V5 lead symbol 80%
• II + V5 + V4 lead symbol 96%
More accurate ischaemia detection
Description
Connection Cable Cover for DIN Type Electrodes for K922
For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;
ZM-920/930/940PG
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
48
Defibrillators > ECG Measurement
Supply Code
K915
Model
Description
BR-916P
6-Lead ECG Electrode Cable, snap, cable length: 0.8m,requires K922
For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PG
Packing unit: 1 pcs
K922
JC-906P
3/6-Lead ECG Connection Cable for K910A/K911/K912/K915 to patient
monitors/defibrillator, cable length: 3.0 m
For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;
ZM-920/930/940PG
Packing unit: 1 pcs
www.nihonkohden.net
ECG 10-Lead Cables
Supply Code
K901
Model
Description
BJ-900P
10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 3.8 m, incl. patient
electrode lead & connection cable
For current products: BSM-1700/3000/5100/6000/9100/TEC-8300
Packing unit: 1 pcs
K354
BJ-831V
10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 2.5 m
For current products: TEC-8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Cables for TEC-5500 & TEC-7700
ECG 3-Lead Cables
ECG 5-Lead Cables
Additional Defibrillator
Connection Cables
50
Defibrillators > ECG Measurement
www.nihonkohden.net
ECG 3-Lead Cables
Supply Code
K120
Model
Description
NA-0003
Electrode Lead Tube, for K911/K910A
For current products: TEC-5500/7700/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 5 pcs
K910A
BR-913P
3-Lead ECG Electrode Cable, clip, cable length: 0.8 m
TEC-5500/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-5500/7700/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
K911
BR-903P
3-Lead ECG Electrode Cable, snap, cable length: 0.8 m
TEC-5500/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-5500/7700/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
K225
BR-018P
3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs
K226
BR-019P
3-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs
K336
JC-005P
Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode Lead
K225/K226/K227/K228
For current products: TEC-5500/7700
Packing unit: 1 pcs
K352A
BC-763VA
3-Lead ECG Connection Cable (AHA), snap, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs
K353A
BC-763V
3-Lead ECG Connection Cable (IEC), snap, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
51
Defibrillators > ECG Measurement
www.nihonkohden.net
ECG 5-Lead Cables
Supply Code
K227
Model
Description
BR-020P
5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs
K228
BR-021P
5-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs
K336
JC-005P
Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode Lead
K225/K226/K227/K228
For old products: TEC-8250/8251
Packing unit: 1 pcs
K352B
BC-765VA
5-Lead ECG Connection Cable (AHA), clip, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs
K353B
BC-765V
5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
52
Defibrillators > ECG Measurement
www.nihonkohden.net
Further Defibrillator Connection Cables
Supply Code
K232
Model
Description
BR-002P
3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m
For old products: TEC-7000
Packing unit: 1 pcs
K350A
BC-753V
3-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 m
For old products: TEC-7500
Packing unit: 1 pcs
K234
BR-004P
5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m
For old products: TEC-7000
Packing unit: 1 pcs
K332
JC-002P
Connection Cable (IEC) for ECG Electrode Lead K234, cable length: 3.0m
For old products: TEC-7000
Packing unit: 1 pcs
K351A
BC-755V
5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 m
For old products: TEC-7500
Packing unit: 1 pcs
L151
JC-761V
External ECG Input Cable, connection to patient monitors, cable length: 2.9 m
For current products: TEC-5500/7700
Packing unit: 1 pcs
L152
JC-762V
External Defibrillator Connection Cable, cable length: 3.0 m,
for ECG Electrode Lead K225/K226/K227/K228
For current products: TEC-5500/7700
Packing unit: 1 pcs
L153
JC-763V
External Defibrillator Connection Cable, cable length: 3.0 m,
for ECG Electrode Lead K910A/K911
For current products: TEC-5500/7700
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Electrodes for Defibrillators
NIHON KOHDEN Vitrode Disposable ECG Electrodes –
The result of over 30 years experience in disposable electrode manufacturing.
The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that
the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an extended period of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause
“noisy’’ ECG signals because of the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting
capabilities intermittently, and this leads to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is
to change these electrodes at least every 48 hours.
Please contact us for individual offer based on your annual volume! Use the possibility of call orders!
Standard Electrodes Placements
It is important to prepare the skin before attaching
the electrodes by cleaning it and removing chest
hair. After this please attach the lead wire to the
electrodes before placing them on the skin. This
avoids pain to the patient. Secure the lead wire to
the skin (stress loop) preventing moving of the
lead wire and therefore noise on the ECG signal.
Three electrodes
Six electrodes
ECG Electrodes for Adults
ECG Electrodes for Children,
Infants & Neonates
Ten electrodes
54
Defibrillators > ECG Measurement
www.nihonkohden.net
ECG Electrodes for Adults
Supply Code
G203
Model
Description
L-150
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape,
solid gel, general use
Packing unit: 5 x 30 pcs
G204
C-150
ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony softcloth with an elastic quality for tension, solid gel
Packing unit: 5 x 30 pcs
G207
L-150X
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray), foam
tape, solid gel
Packing unit: 5 x 30 pcs
G210D
F-150M
ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape
especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
G250
J-150
ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel,
excellent adhesion even on sweaty skin
Packing unit: 5 x 30 pcs
G272A
V-09OM3
ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,
cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape,
3 pre-wired electrodes with 1.5 mm touch proof connector
Packing unit: 30 x 3 pcs
G272B
V-040M4
ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,
cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape,
4 pre-wired electrodes with 1.5 mm touch proof connector for limb leads
Packing unit: 10 x 4 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
55
Defibrillators > ECG Measurement
Supply Code
G272C
Model
Description
V-06OM6
ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,
cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape,
6 pre-wired electrodes with 1.5 mm touch proof connector for chest leads
Packing unit: 10 x 6 pcs
G278A
V-09IO3
ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,
cable length: 1.5 m, radiolucent (X-ray), foam tape,
3 pre-wired electrodes with 1.5 mm touch proof connector
Packing unit: 30 x 3 pcs
www.nihonkohden.net
ECG Electrodes for Children, Infants & Neonates
Supply Code
G210C
Model
Description
F-150S
ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm,
cotton tape especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
G271A
V-120S3
ECG Electrode Vitrode V, Ag/AgCl, neonate/infant, without motif print,
size: 20 mm dia, cable length: 0.6 m, radiolucent (X-ray), foam & cotton tape,
3 pre-wired electrodes with 1.5 mm touch proof connector
Packing unit: 40 x 3 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
SpO₂ Measurement
A Pulse Oximeter is a non-invasive device used to percutaneously measure oxygen saturation
in the blood by use of a clip-on finger probe. Pulse oximeter works with the integration of a
probe placed onto patient’s fingertip or toe, obtains signals from the probe and the main
device calculates oxygen saturation in the body.
Oxygen saturation measured by a Pulse Oximeter is SpO2. “P” stands for “pulse”, and the
measurement principle is based on beat-by-beat changes in blood volume. In general, arterial oxygen saturation measured by spectroscopic analysis is called “SaO2”, and oxygen saturation measured by pulse oximeter is called “SpO2”.
The method for determination of arterial oxygen saturation, based on the photoelectric plethysmography, was conceptualised and implemented in 1972 by the Japanese bio-engineer
Takuo Aoyagi (NIHON KOHDEN Corporation). This idea came about while using an ear densitometer for recording dilution curves for dyes (pigments). The first commercial oximeter
“OLV-5100” was presented by NIHON KOHDEN back in 1975.
Dr. Aoyagi’s innovative technology, pulse oximetry, has rapidly spread worldwide and become essential in critical care. In
2002, Dr. Aoyagi was awarded the Medal of Honor in Japan, in recognition of his great contribution to clinical medicine.
The NIHON KOHDEN SpO₂ Sensors of the BluPRO® Series are at the cutting edge of this progressive technology.
Disposable
SpO2 Cables
Defibrillators > SpO2 Measurement
58
www.nihonkohden.net
SpO2 Cables
Supply Code
K931
Model
Description
JL-900P
SpO2 Connection Cable, cable length: 2.5 m, rectangular connector
For current products: TEC-8300/all BSM/PVM/PSG-1100
Packing unit: 1 pcs
Y095A
JL-550T2
SpO2 Connection Cable, cable length: 2.5 m, round connector
For current products: TEC-5500/7700/JE-912A/921A/921AG
Packing unit: 1 pcs
Note
SpO2 measurement starts when the SpO2 connection cable and SpO2 probe are connected to the device, and the SpO2 probe
is attached to the patient.
When not measuring SpO2, disconnect the SpO2 connection cable from the device. Otherwise, noise from the probe sensor
may interfere and incorrect data is displayed on the screen.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
SpO₂ Probes
BluPRO® SpO₂ Probes – A Unique Sensing Technology
Reliability and high quality of our probes provide a continuous accurate and safe monitoring with highest patient
comfort. The comfortable, sure fitting and lightweight characteristic reduces the effect of hand movement for
highly reliable SpO2 measurement.
This ensures patient safety, reduces the costs of care and increases therefore clinical efficiency and cost
effectiveness. NIHON KOHDEN BluPRO® SpO2 Probes are comfortable, durable, accurate and needs-oriented.
Note that accurate and safe measurement is assured only when you use probes, connection cords and parts manufactured by NIHON KOHDEN. Some probes in the market may advertise as „compatible with NIHON KOHDEN
probes.“ We strongly recommend you to avoid these probes as a correct measurement cannot be guaranteed on
NIHON KOHDEN devices. NIHON KOHDEN is not responsible for problems caused by using other manufacturer’s probes.
Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!
Reusable SpO2 Probes
Disposable SpO2 Probes
Defibrillators > SpO₂ Measurement
60
www.nihonkohden.net
SpO₂ Probes
len
gu
Reusable
Disposable
1000 g
P203A (TL-271T)
0.8
P203E (TL-271T3)
1.6
P204A (TL-271T)
0.8
P204E (TL-271T3)
1.6
P203B (TL-272T)
0.8
P203F (TL-272T3)
1.6
P204B (TL-272T)
0.8
P204F (TL-272T3)
1.6
P203C (TL-273T)
0.8
P203G (TL-273T3)
1.6
P204C (TL-273T)
0.8
P204G (TL-273T3)
1.6
P203D (TL-274T)
0.8
P203H (TL-274T3)
1.6
P204D (TL-274T)
0.8
P204H (TL-274T3)
1.6
P228A (TL-051S)
0.8
P228B (TL-052S)
1.6
P229A (TL-061S)
0.8
P229B (TL-062S)
1.6
P225F (TL-201T)
1.6
P225H (TL-201T1)
0.6
P225G (TL-220T)
1.6
24
5
24
5
24
5
24
5
5
5
1
P311C (TL-631T3)
1.6
P310C (TL-630T3)
1.6
Infant
Child
Adult
nit
m)
h(
gt
el)
od
M
e(
in
ck
Pa
le
d
Co
b
Ca
ply
p
Su
Low birth Neonate
weight
2 kg
3 kg
10 kg
20 kg
30 kg
40 kg
50 kg
61
www.nihonkohden.net
Defibrillators > SpO2 Measurement
Reusable SpO2 Probes
Reusable, but always clean – NIHON KOHDEN washable probes.
The reusable probes of the BluPRO® series are durable and washable,
so you can clean them under running water or even immerse them in a
soapy alkaline or disinfectant solution (glutaraldehyde solution 2.0 %
or hydrochloric alkyl diaminoethylene glycine 0.5 %)!
P225F / P225H
P225G
Durable, washable, demand-oriented!
P310C / P311C
Facts
NIHON KOHDEN reusable SpO2 finger-clips probes have parallel mounted upper and lower sensor shells, thus, providing an exact alignment of the optical sensor components and markedly enhanced comfort during long-term attachment. In addition, flexible lateral flaps shield the measuring signals
from the external light, thus resulting to minimize the interference by additional artificial light sources! Bright LEDs provide more accurate measurement even for thicker fingers or dark skin tones. The finger-clip reusable probe is the most popular type of SpO2 probes. Instead of the typical hinge near
the finger tip, P225F/P225H have a unique sure fitting and comfortable mechanism using two sliding pieces for the front and back of the finger with
two rubber flaps along both sides of the finger. When you press the button, the two halves of the probe slide directly open, parallel to each other. No
additional fixation tape is needed. For a stable and comfortable measurement P225F/P225H, always keep the light emitters and detector aligned. NIHON
KOHDEN provides unique reusable SpO2 probes.
Supply Code Model
Description
P225F
TL-201T
SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger,
cable length: 1.6 m, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs
P225H
TL-201T1
SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger,
cable length: 0.6 m, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs
Facts
The multi-site probe P225G can be used for neonatal feet as well as adult fingers as its curved contact surface is designed to fit on different attachment
sites. The light emitter and detector are separate which allows especially an accurate alignment of the LED on the infant/neonatal instep. A unique sliding
adjuster gives the best fit on the attachment site secured by taping.
Supply Code Model
Description
P225G
SpO2 BluPRO® Multi-Site Probe, neonate (< 3 kg) instep,
child/adult ( > 3 kg) finger/toe, cable length: 1.6 m, reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs
TL-220T
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
62
Defibrillators > SpO2 Measurement
www.nihonkohden.net
Facts
Our special designed finger-tip probes, P310C and P311C, fit immediately on the finger and are perfect for long-term measurement. A less covered finger
area and cushioned materials lead to decrease pressure to the attachment site. The 3D molding attachment ensures a comfortable fit.
In combination with the soft and lightweight design the patient stress or discomfort is reduced and the probes can be remained up to 8 hours to one
attachment site. A stable measurement is assured by gentle fixation tapes P263 or P267 that avoid the falling off of the probes and reduce artifact from
cable movement.
Reusable but with the comfort of a disposable probe, P310C and P311C are also applicable for sleep studies, for patients that are often bending their
fingers or obese patients.
Supply Code
Model
Description
P310C
TL-630T3
SpO2 BluPRO® Finger-Tip Probe L, child/adult (> 50 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs
P311C
TL-631T3
SpO2 BluPRO® Finger-Tip Probe M, child/adult (> 20 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs
P263
P267
Disposable Probe Cable Fixing Tape for P310C/P311C, size: 15 x 130 mm
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 3 x 30 pcs
YS-093P2
Disposable Probe Fastener Tape for P310C/P311C,
size: 15 x 140 mm
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
63
Defibrillators > SpO2 Measurement
www.nihonkohden.net
Disposable SpO2 Probes
NIHON KOHDEN disposable probes, from neonate to adult sizes, place special emphasis on the exact positioning of the LEDs and
detector. For this reason the two optical components are designed separately and can thus be brought into precise alignment
with each other by the user. All probes have breathable material and can be remained up to 8 hours on one attachment site.
Paediatric probes have a cute cartoon character printed on the tape to reassure children.
Self-adhesive, soft and thin tape provides a secure fit. The special design allows an easy application to the attachment site. To get
the most comfortable fit, please bend the probe before attaching, do not strongly pull the attachment tape when attaching and
do not push the tip of the finger with the attachment tape.
Disposable SpO2 Probes 24 pcs/box – cable length: 0.8 m
Supply Code Model
Description
P203A
TL-271T
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
P203B
TL-272T
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
P203C
TL-273T
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
P203D
TL-274T
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
64
Defibrillators > SpO2 Measurement
www.nihonkohden.net
Disposable SpO2 Probes 24 pcs/box – cable length: 1.6 m
Supply Code Model
Description
P203E
TL-271T3
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
P203F
TL-272T3
SpO2 BluPRO® Probe, child ( 10 – 50 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
P203G
TL-273T3
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
P203H
TL-274T3
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m
For current products:all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs
Disposable SpO2 Probes 5 pcs/box – cable length: 0.8 m
Supply Code Model
Description
P204A
TL-271T
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
P204B
TL-272T
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
65
Defibrillators > SpO2 Measurement
Supply Code Model
Description
P204C
TL-273T
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
P204D
TL-274T
SpO2 BluPRO® Probe, infant ( 3 –20 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
www.nihonkohden.net
Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced!
The light emitter and detector are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation.
Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around
the finger with attachment tape P259.
Supply Code Model
Description
P228A
TL-051S
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger,
cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P229A
TL-061S
SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P259
COTTONY Tape for fixing disposable SpO2 Probes
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 20 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
66
Defibrillators > SpO2 Measurement
www.nihonkohden.net
Disposable SpO2 Probes 5 pcs/box – cable length: 1.6 m
Supply Code Model
Description
P204E
TL-271T3
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
P204F
TL-272T3
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
P204G
TL-273T3
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
P204H
TL-274T3
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
67
Defibrillators > SpO2 Measurement
www.nihonkohden.net
Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced! The light emitter and detector
are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation. Since the probe itself is not
self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around the finger with attachment
tape P259.
Supply Code Model
Description
P228B
TL-052S
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P229B
TL-062S
SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P259
COTTONY Tape for fixing disposable SpO2 Probes, disposable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 20 pcs
Handling of the probe affects measurement accuracy and patient safety
For the proper placement of the probe on the finger, it is advisable that the light emitter and detector are placed just opposite to each
other. When using a finger clip probe, it is necessary to ensure that the probe covers the finger properly, otherwise some portion of the light
never passes through the body tissues and may reach the light-receiving part directly, leading to incorrect measurement results.
The more distant the light emitter and detector gets, the weaker the transmitted light intensity becomes. Additionally, a thinner body part
tends to have small amount of blood, which makes it difficult to extract the arterial blood signal component. The most suitable thickness
of the probe site is about 10 mm.
Too loose probes may interfere with alignment of LEDs and detector, come off easily by body movement, cause larger motion artifacts or
be effected by venous pulse.
Too tight probes may cause venous pulsation, cause skin injuries such as burn and necrosis or unstable measurement because of a lower
pulsatile signal.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ETCO2 Measurement (Capnography)
Reasons to measure ETCO₂ (the level of carbon dioxide in the air exhaled from the body –
normal value is about 38 mm Hg): Capnography helps to detect life-threatening problems in:
• Airway
• Breathing
• Circulation and
• Metabolism
Capnography is a fast and reliable help to determinate respiratory difficulties, wrong connections of airway
adapters, leaks in the ventilator circuit due to its placement in the respiratory circuit. An early detection by
capnography might help to avoid inadequate oxygen supply of the body.
69
www.nihonkohden.net
Defibrillators > ETCO2 Measurement
ETCO2 Measurement (Capnography)
The necessity of monitoring ETCO2 is recognized
by various health care associations guidelines:
Capnometer
Mainstream Method
Canadian Anesthesia Society (CAS)
Guidelines for Sedation – January, 2012
In a mainstream system, the
Anesthesia Patient Safety Foundation (APSF)
Monitoring with Use of Post-op Opioids – August, 2011
the patient’s breathing circuit.
sensor is located directly in
Real time measurement values.
American Society for Anesthesiologists (ASA)
Standards for Basic Anesthetic Monitoring – July, 2011
CO2 Sensor
Association of Anaesthetists of Great Britain & Ireland (AAGBI)
The use of capnography outside the operating theatre – May, 2011
American Association of Respiratory Care (AARC)
CPG for Capnography/Capnometry During Mechanical
Ventilation – April, 2011
Capnometer
CO2 Sensor
Sidestream Method
In a sidestream system, a gas
British Royal College of Anesthetists
Airway Recommendation (NAP4) – March, 2011
sample is removed from the
European Resuscitation Council (ERC)
Guidelines for Resuscitation – November, 2010
to a distant sensor.
patient’s airway and delivered
Measurement values delayed.
Suck in
American Heart Association (AHA)
Resuscitation Guideline – November, 2010
Not possible with
Sampling tube
NIHON KOHDEN defibrillators.
ETCO2 Selection Guide
Start
Yes
No
Is CO2 the only gas to measure?
No
Is the patient a neonate?
Multi-gas measurement
Please use NIHON KOHDEN
patient monitors!
Yes
No measurement possible
Mainstream measurement
Yes
Is the patient intubated?
No
Emergency
No
Is a humidifier or nebulizer used?
CO2 sensor kit
P907 (TG-920P) & P908 (TG-921T3)
No
Both intubated & non-intubated
Yes
With nebulizer
CO2 sensor kit P909 (TG-970P)
Intubated
R805 (YG-211T) Airway adapter adult (> 7 kg)
R804 (YG-111T) Airway
adapter (> 7 kg)
Non-intubated
V921 (YG-120T) Nasal adapter (> 10 kg)
V922 (YG-121T) Nasal/Oral adapter (>10 kg)
CO2 sensor kit P903 (TG-900P)
V923 (YG-122T) Nasal/Oral adapter with O₂
supply tube adapter (> 10 kg)
R801 (YG-101T) Airway adapter adult, (> 10 kg)
NKD-02-Cap Oxygen cannula
CO2 sensor kit P909 (TG-970P)
R805 (YG-211T) Airway adapter adult (> 7 kg)
ETCO2 Measurement Overview
The best way to observe the patient‘s respitatory condition
ETCO2 shows clinical and technical problems
mmHg
45
35
Normal capnograph and ETCO2 waveform
Hypoventilation
Increasing CO
Malignant high fever
Pain of light anesthesia
ETCO2
Normal range
Hyperventilation
Decreasing CO
Pulmonary embolism
Deep anesthesia
Hyperventilation
Normal range: steep rising and flat expiratory phase
PaCO2 level
Breathing circuit abnormality
Hypoventilation
Respiratory abnormality
· Breathing circuit abnormality
Trend
· Downward
· Obstructive defect, bronchial spasm ETCO2=PaCO2
40
· Upward
40
40
40
Sudden decrease of CO2
Gentle expiratory phase
· Ventilation disconnection
· Rebreathing
40
40
40
40
Sudden decrease of CO2 toward zero
Hyperventilation
Decreasing CO
Pulmonary embolism
Temperature decrease
Gentle expiratory phase
· Spontaneous breathing
· Esophageal intubation
40
40
Zero CO2 or very low CO2
Start exhalation
of CO2 in alveoli
of the lung
Sudden disappearance of
CO2 waveform
Conditions reflected by ETCO2
Blood
circulation
Beginning of
exhalation
Partial obstruction of
breathing circuit
Disconnection in
breathing circuit
Asphyxia
Ventilator stop
Cumulative irregular respiratory waveform
5 phases of the capnograph
Hypoventilation
Temperature increase
Malignant high fever
Plateau of CO2 in
alveoli of the lung
End of
exhalation
Breathing
Airway
Connector
CO2
Inhalation
phase
Respiratory Circuit
monitor
Gas exchange
Metabolism
Pulmonary circulation
Ventilator
CO2 absorber
Fresh gas
Early detection of trouble in breathing or ventilation equipment
Inadequate
ventilation
Kink
ETCO2 and PaCO2 show ventilation and pulmonary blood flow condition
Indequate
gas flow
Disconnection
Normal ventilation
Malfunction
Abnormal ventilation and
normal pulmonary blood flow
40 mmHg
( ETCO2)
46 mmHg
40
40
46 mmHg
20 mmHg
( ETCO2)
40 mmHg
( ETCO2)
46 mmHg
40
40
Normal ventilation and
abnormal pulmonary
blood flow
46 mmHg
46 mmHg
40
46
40
40
46 mmHg
0
40
Leak
40 mmHg ( PaCO2)
Esophageal intubation
43 mmHg ( PaCO2)
40 mmHg ( PaCO2)
Apnea Obstruction
CO2 Measurement is useful in many hospital sites
ER
Neonate
OR
ICU
PSG
Nihon Kohden Unique Sensing Technology
With ventilator or
nebulizer
Sedation
Both intubated and non-intubated cap-ONE CO2 Sensor
ETCO2 Mainstream
Application Fields of Airway Adapters for
Intubated Patients
Application Fields of Nasal Adapters for
Non-Intubated Patients
Emergency / Pre-hospital Care
Transport / Pre-hospital Care
• Detection of endotracheal tube
displacement
• Detection of changes in respiratory status
(over- or underventilation of trauma / shock
victims; COPD patients)
• Control of CPR efficacy
• ROSC detection
(Return of Spontaneous Circulation)
• Oxygenation management
• Detection of respiratory depression of
sedated patients or anaesthesia without
intubation
• Airway circuit management
• Spot-checking of ETCO2 level & respiration
rate of critically ill non-intubated patients
• Keeping ICP appropriate by checking ETCO2 level
(i.e. patients with craniocerebral injury – CCI)
• Detection of effectiveness of treatment
• Detection of respiratory distress
(occlusion, connection leak, accidental
extubation, ventilator trouble etc.)
• Detection of poor pulmonary perfusion
• Apnea monitor
• Detection of effectiveness of treatment
72
Defibrillators > ETCO2 Measurement
www.nihonkohden.net
Intubated Expired ETCO2
Supply Code
Model
Description
P906
TG-901T3
CO2 Sensor Kit for Intubated Patients, semi-quantitative measurement,
incl. CO2 sensor and CO2 adapter, expiratory CO2, cable length: 3.0 m
For Airway Adapters: R801
For current products: TEC-5500/7700
Packing unit: 1 pcs
P903
TG-900P
CO2 Sensor Kit for Intubated Patients, semi-quantitative measurement,
incl. P922A/K981, expiratory CO2, cable length: 3.0 m
For Airway Adapters: R801
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
P922A
TG-101T
CO2 Sensor for Expiratory CO2 for Intubated Patients, part of CO2 Sensor Kit P903,
cable length: 1.0 m, requires Adapter Cable: K981
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
K981
JG-900P
CO2 Adapter Cable for P922A/P903, cable length: 2.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
R801
YG-101T
Airway Adapter for P903/P906/P922A, intubated, semi-quantitative method,
child/adult (>10 kg), dead space: 5 ml
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 50 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
73
Defibrillators > ETCO2 Measurement (Capnography)
www.nihonkohden.net
Intubated Expired and Inspired ETCO2
“Opening a New Era in Capnography“
Facts
NIHON KOHDEN CO2 Sensor Sensation - P909 World‘s smallest and lightest mainstream ETCO2 sensor (quantitative method) with only 4 g (±2 g).
This avoids tube pressures and increases patient comfort. Especially for this reason as well as the dead space of approximately 1 ml it is perfectly suited to
the most sensible intubated patients – neonates in critical care (application on neonates only with patient monitors). Besides this P909 can be also applied
to children and adults. Easy and simple handling is guaranteed by its waterproofness (IPX7 standard) and our Smart CableTM Technology so that no additional
module is needed. Just plug in and start a continuous measurement after only 10 seconds warm-up time. Those features make the P909 an unbeatable help for
daily work routine in OR, ER, ICU or Ward.
Supply Code
Model
Description
P909
TG-970P
cap-ONE CO2 Sensor Kit for Intubated Patients,
quantitative measurement, incl. P924/K987,
size: 8 x 13 x 35 mm, cable length: 3.5 m
For Airway Adapters: R805
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs
P924
TG-221T
cap-ONE CO2 Sensor for Intubated Patiens, part of CO2 Sensor Kit P909,
cable length: 3.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs
K987
JG-970P
cap-ONE CO2 Adapter Cable for P909/P924, cable length: 0.5 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs
R805
YG-211T
Airway Adapter for P909, intubated, quantitative method, adult (> 7 kg),
dead space: 4 mL
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
74
Defibrillators > ETCO2 Measurement (Capnography)
www.nihonkohden.net
Intubated and Non-Intubated Expired ETCO2
“Opening a New Era in Capnography“
Facts
NIHON KOHDEN cap-ONE–when every breath counts!
World’s first wearable mainstream ETCO2 sensor P907 (semi-quantitative method) for intubated and non-intubated patients which is applicable for
children and adults.
Unique oral-nasal airway adapters catch oral as well as nasal expired CO2 – this increases accuracy. The cap-ONE is not only small but has also a
mini-weight of only 4 g. This avoids tube pressures and increases patient comfort. Easy and simple handling is guaranteed by our Smart CableTM Technology so
that no additional module is needed, just plug in and start measuring after only 5 seconds. A continuous, stable and accurate measurement is ensured
due to no lag time and no need to change tubes because of occlusions. Its waterproofness and outstanding shock resistance are an unbeatable advantage in daily work routine.
Those features make the cap-ONE P907 an excellent measurement tool in OR, ICU, Recovery Room, PACU, Transport, ER, Cardiac Catheter Laboratory,
GI Endoscopy, Pain Management, Abdominal Operation, Obstetric/Orthopedic/Eye Surgery, Plastic or Dental Surgery.
Supply Code
Model
Description
P908
TG-921T3
cap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients,
semi-quantitative measurement, incl. CO2 sensor and CO2 Adapter,
size: 11 x 11 x 40 mm, cable length: 3.5 m
For Airway Adapters:
Intubated patients: R804
Non-Intubated patients: V921/V922/V923
For current products: all EEG/TEC-5500/7700; EEG-1200/9100/9200
with JE-921A/921AG
Packing unit: 1 pcs
P907
TG-920P
cap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients, semi-quantitative
measurement, incl.P923/K984, size: 11 x 11 x 40 mm, cable length: 3.5 m
For Airway Adapters:
Intubated patients: R804
Non-Intubated patients: V921/V922/V923
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs
P923
TG-121T
cap-ONE CO2 Sensor for Intubated/Non-Intubated Patients, part of CO2 Sensor Kit
P907/P908, cable length: 1.5 m
Requires Adapter Cable: K984
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs
K984
JG-920P
cap-ONE CO2 Adapter Cable for P923/P907, cable length: 2.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
75
Defibrillators > ETCO2 Measurement (Capnography)
Supply Code
Model
Description
R804
YG-111T
Airway Adapter for P907/P908/P923, intubated, child/adult (> 7 kg),
dead space: 4 mL
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 30 pcs
V921
YG-120T
CO2 Nasal Adapter for Nasal Breathing, non-intubated, child/adult (> 10kg)
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100
Packing unit: 30 pcs
V922
YG-121T
CO2 Nasal Adapter for Nasal/Oral Breathing, non-intubated, child/adult (> 10 kg)
For current products:all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100
Packing unit: 30 pcs
V923
YG-122T
CO2 Nasal Adapter for Nasal/Oral Breathing with Oxygen Cannula Holder,
non-intubated, child/adult (> 10kg)
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100
Packing unit: 30 pcs
NKD-O2-CAP
Oxygen Cannula for Nasal Adapter V923 for P907/P908
For current products: all BSM/PMV-2703/OLG-2800/TEC-8300/EEG
Packing unit: 50 pcs
NKD-CO2GAS
Calibration Gas for CO2 Measurement
Please store the gas below 50°C!
For current products: all BSM/TEC-8300
Packing unit: 1 pcs
NKD-VENTIL3
CO2 Gas Valve
For current products: all BSM/TEC-8300
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Temperature Measurement
Standard
Temperature
Measurement of
2 Additional Temperatures
77
Defibrillators > Temperature Measurement
www.nihonkohden.net
Standard Temperature Measurement
Supply Code
Model
Description
NKD-P240A
YSI-401
Oesophagus/Rectum Thermistor Probe, adult, 6.3 mm jack connector,
size: 4 mm dia, length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-P241A
YSI-402
Oesophagus/Rectum Thermistor Probe, neonate/child, 6.3 mm jack connector,
size: 3.3 mm dia, length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-P242B
YSI-409B Body Surface Temperature Probe, 6.3 mm jack connector, disk size: 9.5 mm dia,
cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 1 pcs
NKD-P249
ZM: S616
Temperature Probe Cover for NKD-P240A/241A
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 10 pcs
NKD-TEMPHEARTS4009
Tempheart Adhesive Pads, to fix temperature probes, size: 1.5 cm dia
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 100 pcs
NKD-TEMPHEARTS4012
Mini-Tempheart Adhesive Pads, to fix temperature probes, size: 1.13 cm dia
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 100 pcs
Measurement of 2 Additional Temperatures
Supply Code
Model
Description
K961
JT-900P
Temperature Connection Cable for NKD-P241/242x, cable length: 0.3 m
For current products: BSM-5100/6000/9100/ TEC-8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
NIBP Measurement (Non-Invasive Blood Pressure)
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the blood
pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the condition
of the pumping function of the heart as an important vital sign.
A non-invasive indirect method to measure the blood pressure is the oscillometric blood pressure measurement. This method is using an inflated blood pressure cuff which is applied to the patient’s arm or thigh. The blood pressure is detected
by partial occlusion of the artery by the cuff. The so called Korotkoff sound is generated by the distension of the arterial
wall with each cardiac impulse. Systolic and diastolic blood pressures are determined by an algorithmic interpretation of
the device based on the mean arterial pressure and changing amplitude of the Korotkoff sounds.
For a proper non-invasive measurement it is important to use the correct cuff size due to the fact that a cuff too small will
lead to faulty high pressure, while a large cuff can lead to wrong low pressure readings.
NIBP Air Hoses
Reusable NIBP Cuffs – NEW YAWARA CUFF 2
Disposable NIBP Cuffs
79
Defibrillators > NIBP Measurement (Non-invasive Blood Pressure)
www.nihonkohden.net
NIBP Air Hoses
Supply Code
Model
Description
S901
YN-900P
Child/Adult NIBP Air Hose, cable length: 1.5 m
For current products: all BSM/PVM/TEC-7700/8300
Packing unit: 1 pcs
S902
YN-901P
Child/Adult NIBP Air Hose, cable length: 3.5 m
For current products: all BSM/PVM/TEC-7700/8300
Packing unit: 1 pcs
S903
YN-990P
NIBP Air Hose Extension Cable, cable length: 1.5 m
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Defibrillators > NIBP Measurement (Non-invasive Blood Pressure)
80
www.nihonkohden.net
Reusable NIBP Cuffs – NEW YAWARA CUFF 2
• Soft and gentalon the skin
• Highly accurate
• Easy to use
Facts
The trade name YAWARA CUFF comes from the Japanese word, YAWARAKAI, which
means soft in touch.
YAWARA CUFF 2 is available in 6 sizes. The exterior size-scale quickly helps in
selecting the proper cuff size, from infant to large adult or thigh.
The velcro part of the cuff is divided into two high quality velcro types. This helps
to fix the cuff on the arm with the first velcro part whereas you can completely
adjust the cuff with the second velcro part.
YAWARA CUFF 2 uses a soft and smooth cloth together with a buffer sheet to reduce
the risk of subcutaneous bleeding. The fabric is hypoallergic and allows the skin to
breathe. Furthermore, the material of the cloth can be easily wiped clean.
A wider opening of the cuff cover allows very easy removal of the bladder for
cleaning.
The watertight connector cap keeps out liquid during cleaning the bladder. There
is a nylon fibre inside the air tube for kink-free tube. There is a nylon fibre inside the
air tube preventing kinking and incidents associated with tube kinking. YAWARA
CUFF 2, a new generation of NIBP cuffs.
Reducing internal bleeding
If wrinkles are formed as below, part of the measuring site may be
trapped in the valley portions of the wrinkles, which could cause internal
bleeding. YAWARA CUFF 2 has a cushion between an inflation bag and skin
to avoid these wrinkles and reduces internal bleeding.
Easy handling of
an inflation bag
inflation bag
wrinkles
With a wide slit, it is easy
to remove and replace the
inflation bladder.
cushion
Indicator of appropriate
range of attachment site
Easy to clean with watertight
connection cap
Kink-free tube
With a clear indication of
PROPER SIZE printed on the
cuff, you can see at a glance
if the cuff size is correct for
your patient.
YAWARA CUFF 2 has a watertight
connector cap, which prevents
fluid from entering the tube (and
bladder) during cleaning.
YAWARA CUFF 2 has a kink-free
tube. The tube will not
kinked - even if bent through
a 180-degree angle.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
81
Defibrillators > NIBP Measurement (Non-invasive Blood Pressure)
Supply Code
Model
Description
S951A
YP-710T
Infant NIBP YAWARA CUFF 2, width: 5 cm, arm-circumference: 8 to 13 cm, latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S951B
YP-711T
Child NIBP YAWARA CUFF 2, width: 7 cm, arm-circumference: 13 to 19 cm, latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S951C
YP-712T
Adult Small NIBP YAWARA CUFF 2, width: 10 cm, arm-circumference: 19 to 23 cm,
latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S951D
YP-713T
Adult NIBP YAWARA CUFF 2, width: 13 cm, arm-circumference: 23 to 33 cm, latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S951E
YP-714T
Adult Large NIBP YAWARA CUFF 2, width: 16 cm, arm-circumference: 33 to 45 cm,
latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S951F
YP-715T
Adult Thigh NIBP YAWARA CUFF 2, width: 19 cm, thigh-circumference: 45 to 55 cm,
latex-free
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
82
Defibrillators > NIBP Measurement (Non-invasive Blood Pressure)
www.nihonkohden.net
Disposable NIBP Cuffs
Disposable NIBP Cuffs for Infants & Children
Supply Code
Description
NKD-NIBP/K2
Disposable NIBP Cuff Trial Kit for Children
Set contains:
3 cuffs of NKD-S947A
4 cuffs of NKD-S947B
3 cuffs of NKD-S947C
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 set
NKD-S947A
Infant NIBP Cuff, width: 6 cm, arm-circumference: 8 to 14 cm, color: blue, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947B
Child NIBP Cuff, width: 8 cm, arm-circumference: 13 to 20 cm, color: green, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947C
Small Adult NIBP Cuff, width: 10 cm, arm-circumference: 18 to 26 cm,
color: orange, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs D
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
83
Defibrillators > NIBP Measurement (Non-invasive Blood Pressure)
www.nihonkohden.net
Disposable NIBP Cuffs for Adults
Supply Code
Description
NKD-NIBP/K3
Disposable NIBP Cuff Trial Kit for Adults
Set contains:
1 cuff of NKD-S947C
4 cuffs of NKD-S947D
3 cuffs of NKD-S947F
2 cuffs of NKD-S947H
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 set
NKD-S947C
Small Adult NIBP Cuff, width: 10 cm, arm-circumference: 18 to 26 cm,
color: orange, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947D
Adult NIBP Cuff, width: 14 cm, arm-circumference: 26 to 35 cm,
color: blue, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947E
Adult Long NIBP Cuff, width: 15 cm, arm-circumference: 29 to 38 cm,
color: red, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947F
Large Adult NIBP Cuff, width: 17 cm, arm-circumference: 32 to 42 cm,
color: green, latex-free, disposable
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947G
Large Adult Long NIBP Cuff, width: 18 cm, arm-circumference: 35 to 44 cm,
color: orange, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947H
Adult Thigh NIBP Cuff, width: 20 cm, arm-circumference: 42 to 50 cm,
color: blue, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
IBP Measurement (Invasive Blood Pressure)
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the
blood pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the
condition of the pumping function of the heart as an important vital sign.
A direct method to measure the blood pressure is the invasive blood measurement using catheters inserted into the
blood vessels, filled with saline solution and measure the pressure electrically with a connected transducer.
Transducer Cable with Direct Connection
IBP Transducer Cable with
Adapter Cable K952
85
Defibrillators > IBP Measurement (Invasive Blood Pressure)
www.nihonkohden.net
IBP Transducer Cable with Direct Connection
Supply Code
Model
Description
K951
JP-900P
IBP Connection Cable for Becton Dickinson Transducers, cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
K952
JP-910P
IBP Adapter Cable for IBP Transducer Cables, BF type, cable length: 0.3 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
K957
JP-960P
IBP Connection Cable for Biosensors Transducers, cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
L901
JP-920P
IBP Connection Cable for Edwards Lifesciences Transducers, cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
L902
JP-921P
IBP Connection Cable for Edwards Lifesciences Transducers, cable length: 1.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
86
Defibrillators > IBP Measurement (Invasive Blood Pressure)
www.nihonkohden.net
IBP Transducer Cable with Adapter Cable K952
Supply Code
Description
NKD-5203201
IBP Connection Cable for B. Braun Transducers, cable length: 3.0 m, requires K952
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-BDP178NK1
IBP Connection Cable Set for Codan Transducers, incl. adapter cable with
1 Pressure Connection, contact board Xtrans BDC901 and holding plate B180090,
cable length: 0.5 m, requires K952
Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 set
NKD-BDP178NK4
IBP Connection Cable for Codan Transducers with 4 Pressure Connections,
cable length: 0.5 m, requires K952
Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-BDPT-1078
IBP Connection Cable for Codan Transducers with 1 Pressure Connection,
cable length: 3.5 m, requires K952
Applicable for Codan Transducers: Series xTrans: DPT-6000
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/LOGICAL
IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/LOGICAL2
IBP Connection Cable for Medex Transducers with 2 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
87
Defibrillators > IBP Measurement (Invasive Blood Pressure)
Supply Code
Description
NKD-IBP/LOGICAL3
IBP Connection Cable for Medex Transducers with 3 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/LOGICAL4
IBP Connection Cable for Medex Transducers with 4 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/NOVATRANS
IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Novatrans
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/TRANSPAC
IBP Connection Cable for TRANSPAC Transducers with 1 Pressure Connection,
cable length: ca. 4.5 m, requires K952
Applicable for Abbott Transducers: Transpac IT, Transpac IV
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/TRANSTAR
IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Transtar
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/UTAH
IBP Connection Cable PMK225 for Pulsion Transducers for PiCCO 2 and PiCCO plus
with 1 Pressure Connection, cable length: 3.0 m, requires K952 and NKD-IBP/UTAH2
Applicable for Pulsion Transducers for PiCCO: PV81x, PV82xx
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/UTAH2
AUX Adapter Cable PC85200 to External Monitor for Pulsion PiCCO 2,
cable length: 0.3 m, requires NKD-IBP/UTAH
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
88
Defibrillators > Portable CPR
www.nihonkohden.net
Portable CPR – For use by anyone!
Reusable, portable and smart – a simple and fast emergency aid tool for chest compression!
For inexperienced users, for first aid trainings, in hospitals, airports and aircrafts/trains and/or for rescue operations.
Continuous acoustic and visual real time feedback for compression
frequence and depth during chest compression
(metronome/verbal directions/light-emitting diodes)
Perfecting of chest compression effectiveness
(ideal compression depth 4 - 5 cm, 100 compressions/minute)
complies with current ERC Guidelines
Ideal tool for professionals and inexperienced users due to
continuous real time feedback during chest compression
Enhancement of patient status due to optimized quality and
effectiveness of chest compression (detectable with ETCO2 value)
NKD-CPR
• Applicable to adults and children from 8 years!
• 10 hours non-stop operation (acoustic warning) or up to 5 years stand-by time!
• Available in 17 different languages!
(stock: German, English, Italian, French, Spanish; on request: Danish, Finnish, Dutch, Hungarian, Czech, Norwegian,
Polish, Portuguese, Russian, Swedish, Hebrew, Croatian)
Only a few steps may help save a life:
• Stay calm!
• Check the responsiveness/consciousness of the person with cardiac arrest (victim)!
• Call to an emergency doctor! / Call for help!
• If available, use an AED (defibrillator for inexperienced users with verbal directions / visual aid) and a Pocket CPR!
• Check the breathing of the concerned person (victim) and free the airway if necessary!
• Start chest compression (30 x) and perform rescue breathing to the victim (2 x)!
• Continue with chest compressions and rescue breaths in a ratio of 30:2
(30 chest compressions, 2 rescue breaths) until the appearance of the emergency doctor!
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
89
Defibrillators > Portable CPR
www.nihonkohden.net
Portable CPR
Supply Code
Description
NKD-CPR
Portable CPR
Please indicate your language when ordering!
Available languages on stock : German, English, French, Italian, Spanish
Available languages on request: Danish, Finnish, Dutch, Hungarian, Czech,
Norwegian, Polish, Russian, Swedish, Hebrew, Croatian
Packing unit: 1 pcs
NKD-SIPADS
Disposable Silicone Pads for Portable CPR, 3 mm self-adhesive silicone pads for
optimal placement of the Portable CPR on patients chest
Packing unit: 5 pcs
NKD-STPADS
Disposable Sticky Pads for Portable CPR, thin self-adhesive pads for optimal
placement of the Portable CPR on patients chest
Packing unit: 50 pcs
NKD-CPR/COVER
Silicone Cover for Portable CPR
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Additional Defibrillator Accessories
91
Defibrillators > Additional Defibrillator Accessories
www.nihonkohden.net
Additional Defibrillator Accessories
Supply Code
Model
Description
F015
Z-101EA
“Gelaid” Defibrillator Contact Gel, 100 g tube
For current products: all TEC
Packing unit: 5 pcs
NKD-JJ221V
R2 Adapter Cable for Laerdal/Ambu Training Doll, requires R2
Adapter cable JC-755V/K342A
For current products: TEC-5500/7700/8300
Packing unit: 1 pcs
NKD-L936
Power Cable, Schuko plug, cable length: 2.0 m
Packing unit: 1 pcs
NKD-POWERLINE
Multiple Power Socket (4 slots), medical certification
For current products: all TEC
Packing unit: 1 pcs
NKD-SD1GB
Memory SD Card 1 GB
Packing unit: 1 pcs
Y011
404617
Thermal Head Cleaner Pen
For current products: all ECG/TEC/old MEB/EEG/all BSM/PVM/OPV/WEP
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Accessories for AED & Training Unit
Dont let premature death
claim the lives around you
Sudden Cardiac Arrest (SCA) is among the leading causes of death in the
world. In SCA, the heart suddenly and unexpectedly stops functioning.
When this happens, the heart is no longer able to pump blood to the rest
of the body. This usually results in death if not treated within minutes.
Heavy chest pains, nausea and weakness are common symptoms of SCA.
More often than not, the victim also feels an impending sense of doom
reflecting their predicament.
SCA can strike anytime and any place, and can happen to anyone.
Dont let SCA claim lives prematurely when something can be done about it.
ACT NOW!
Give every life a chance to live.
94
Defibrillators > Accessories for AED & Training Unit
www.nihonkohden.net
A strong Chain of Survival
improves chance of survival
The “Chain of Survival” is a proven approach to the early treatment of sudden cardiac
arrest, heart attack, stroke and any other emergency. It consists of four crucial links:
EARLY ACCESS
to get help
EARLY CPR
to buy time
EARLY DEFIBRILLATION
to restart heart
EARLY ACLS
to stabilize
1. Early Access - to activate the Emergency Medical Services (EMS).
2. Early Cardiopulmonary Resuscitation (CPR) – to slow the rate of deterioration
of the brain and heart, and buy time to enable defibrillation.
3. Early Defibrillation – to restore to a normal heart rhythm.
4. Early Advanced Cardiac Life Support (ACLS) – to stabilise the patient.
Any delay in any of these links could potentially be fatal or decrease the chance of survival.
Most people who die of heart attacks experience irregular heartbeats known as ventricular
fibrillation (VF); a condition where the heart stops circulation of blood. lf left untreated, the
victim will die within minutes. By far, defibrillation (electric shock) is the only known treatment to revert a troubled heart from VF to its normal rhythm.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
95
Defibrillators > Accessories for AED & Training Unit
www.nihonkohden.net
Importance of AED in the Chain of Survival
Automated External Defibrillator or AED is perhaps the most important
link in the chain to improve the SCA victim‘s survival chances.
An AED is a device that is used to diagnose and treat potentially life threatening abnormal heart rhythms by providing the means to apply controlled electrical shocks (known as defibrillation shocks) to the heart in
an attempt to stop these abnormal rhythms, thereby allowing the heart
to establish again an effective rhythm.
It will also provide guidance by simple and clear vocal instructions to the
rescuer during the rescue sequence.
Studies have shown that the time to first defibrillation shock is the most
crucial factor in determining survival rates for SCA*. When an AED is
available, it should always be applied to the SCA victim at the earliest.
* Report of Japan FDMA (Fire and Disaster Management Agency/2008)
50,0%
45,0%
43,8%
40,0%
35,0%
38,2%
30,0%
25,0%
20,0%
15,0%
10,0%
0,5%
9,8%
5,6%
0
Survival rate
(after 1 month)
For over 90% of SCA cases,
death usually occurs if
without intervention.
However, as many as
30-50% would likely
survive if AED and CPR
was administered within
first 5 minutes of collapse.
Survival chance can
be significantly increased
with early defibrillation.
Use AED
Non use AED
Rehabilitation rate
(after 1 month)
For every minute of delay in giving CPR and defibrillation following collapse, the survival rate
decreases
by 7–10%. So, why let tragedies happen where there is prevention available now?
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
The
result
ofarenot
having
AED
be another
fatalPlease
case.
Reusable
accessories
intended
for repeatedan
patient
use onmay
different well
patients during
different examinations.
make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
96
Defibrillators > Accessories for AED & Training Unit
www.nihonkohden.net
Accessories for AED Units
Supply Code
Model
Description
H324A
P-530K
Defibrillation Pads, child/adult, for use with adapter cable JC-765V/K342B,
weight: 85 g ± 15 g), size: 109 mm x 15 mm (± 10 mm),
conductive surface: 86.68 cm2 (±10%), cable length: 1.5 m
For current products: AED-21xx
Packing unit: 1 pair
SB-210VK
X212A
2-Years Standby Battery for all devices until SN: 5000
For current products: AED-21xx
Packing unit: 1 pcs
SB-212VK
X216A
2-Years Standby Battery for all devices starting from SN: 5001
For current products: AED-21xx
Packing unit: 1 pcs
SB-214VK
X217A
4-Years Standby Battery for all devices starting from SN: 5001
For current products: AED-21xx
Packing unit: 1 pcs
Y184A
YC-210V
AED Carrying Bag.
AED usage is possible without taking
out from the bag!
For current products: AED-21xx
Packing unit: 1 pcs
Accessories for AED Training Unit TRN-2100K
Supply Code
Description
H326
Training Pads, child/adult
For current products: TRN-2100K
Packing unit: 1 pair
Y262B
Replacement Stickers for TRN-2100K Training Pads
For current products: TRN-2100K
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
www.nihonkohden.net
ACCESSORY ORDER FORM
For your convenience we have a printable order form so that you can fax in your order directly or mail/e-mail it to us.
Please make sure to fill out all the information requested below!
Hospital/Practice
Contact Person
Department
Customer Code
Address
ZIP
City
Phone
Fax
E-Mail
ACCESSORY ORDER FORM
3 Days
2 Days
Monthly, please contact me for more details
Other
Standard
Supply Code
Description
Send in your order today!
Required Quantity
Overnight
Price each in EUR / £
For Germany, Austria, Switzerland and Benelux
Fax: +49 (0) 33203/573-19, E-Mail: [email protected]
For Spain and Portugal
Fax: +34 91 300 46 76, E-Mail: [email protected]
For United Kingdom
Fax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]
Price Total in EUR / £
For France
Fax: +33 (0) 1 49 08 93 32, E-Mail: [email protected]
For Italy
Fax: +39 (0) 35-232546, E-Mail: [email protected]
For all other European Countries, Russia, Turkey
and Israel
Fax: +49 (0) 6003/827-599, E-Mail: [email protected]
98
www.nihonkohden.net
Index as per Supply Code
Index as per Supply Code
Supply Code
page
Supply Code
page
Supply Code
page
Supply Code
page
6124-039432
47
JC-755V
39
K901
48
KB18B
14
A052
25
JC-765V
38
K910A
47, 50
KB19C
14
A053
25
K079
13
K910A
47, 50
L151
52
A128
25, 34
K081
13
K911
47, 50
L152
52
A129
25
K082
13
K912
47
L153
52
A222
34
K093C
13
K913A
47
L901
85
A226
34
K093D
13
K915
48
L902
85
A238
34
K093F
13
K922
48
N-00
21
F010
28
K093L
14
K931
58
N-08
21
F015
91
K096A
13
K951
85
ND-593V
42
G203
20, 54
K096B
13
K952
85
ND-594V
42
G204
20, 54
K097
15
K957
85
ND-595V
42
G207
20, 54
K098
15
K961
77
ND-596V
42
G210C
21, 55
K117A
29
K981
72
ND-597V
42
G210D
20 ,54
K117B
29
K984
74
ND-612V
42
G236
20
K117C
29
K987
73
ND-893V
41
G250
20, 54
K118
14
KB01A
14
ND-894V
41
G271A
55
K119
14
KB02A
14
ND-895V
41
G272A
54
K120
47, 50
KB03A
14
ND-896V
41
G272B
54
K225
50
KB04A
14
ND-897V
41
G272C
55
K226
50
KB05A
14
NKD-145-2,5
26
G278A
55
K227
51
KB06A
14
NKD-145-6A300
26
H041A
18
K228
51
KB07A
14
NKD-210-10/295
25
H043A
18
K232
52
KB08A
14
NKD-210-5-295
25
H044A
18
K234
52
KB09A
14
NKD-5203201
86
H044B
18
K332
52
KB010
14
NKD-63
26
H049
18
K336
50, 51
KB012
14
NKD-A054
25
H052A
18
K342A
39
KB10C
14
NKD-A129
26
H052B
18
K342B
38
KB11C
14
NKD-A134A
26
H068A
17
K350A
52
KB12D
14
NKD-A226
34
H068B
17
K351A
52
KB13B
14
NKD-A730
25
H072
17
K352A
50
KB13D
14
NKD-BAG
28
H312
38
K352B
51
KB14B
14
NKD-BDP178NK1
86
H324A
96
K353A
50
KB15B
14
NKD-BDP178NK4
86
H326
96
K353B
51
KB16B
14
NKD-BDPT-1078
86
H327
38
K354
48
KB17B
14
NKD-CO2GAS
75
99
www.nihonkohden.net
Index as per Supply Code
Index as per Supply Code
Supply Code
page
Supply Code
page
Supply Code
page
Supply Code
page
NKD-CPR
89
NKD-S947E
83
P229A
65
V923
75
NKD-CPR/COVER
89
NKD-S947F
83
P229B
67
X040
23
NKD-DEFIBAG2
36
NKD-S947G
83
P259
65, 67
X041
32
NKD-DEFIBAG3
36
NKD-S947H
83
P263
62
X041A
23
NKD-DEFIBAG6
36
NKD-SD1GB
28, 91
P267
62
X041B
23, 32
NKD-DEFIBAG83
36
NKD-SIPADS
89
P310C
62
X060A
32
NKD-ECG/TAB1
19
NKD-STPADS
89
P311C
62
X065
23, 32
NKD-ECG/TAB2
19
NKD-STRAP83
36
P903
72
X071
23
NKD-G711
28
NKD-TEMPHEARTS4009 77
P906
72
X073
23
NKD-H/ADAPTER2
19
NKD-TEMPHEARTS4012
77
P907
74
X077
32
NKD-H405
39
NKD-VENTIL3
75
P908
74
X078
23
NKD-H406
39
NKD-Z715
19
P909
73
Y011
28, 91
NKD-IBP/LOGICAL
86
NKD-Z722
19
P922A
72
Y095A
58
NKD-IBP/LOGICAL2
86
NKD-Z723
19
P923
74
Y184A
96
NKD-IBP/LOGICAL3
87
P203A
63
P924
73
Y206A
38
NKD-IBP/LOGICAL4
87
P203B
63
R801
72
Y206B
39
NKD-IBP/NOVATRANS
87
P203C
63
R804
75
Y262B
96
NKD-IBP/TRANSPAC
87
P203D
63
R805
73
NKD-IBP/TRANSTAR
87
P203E
64
S901
79
NKD-IBP/UTAH
87
P203F
64
S902
79
NKD-IBP/UTAH2
87
P203G
64
S903
79
NKD-JJ221V
91
P203H
64
S951A
81
NKD-L936
28, 91
P204A
64
S951B
81
NKD-NIBP/K2
82
P204B
64
S951C
81
NKD-NIBP/K3
83
P204C
65
S951D
81
NKD-O2-CAP
75
P204D
65
S951E
81
NKD-P240A
77
P204E
66
S951F
81
NKD-P241A
77
P204F
66
SB-210VK
96
NKD-P242B
77
P204G
66
SB-212VK
96
NKD-P249
77
P204H
66
SB-214VK
96
NKD-POWERLINE
28, 91
P225F
61
SB-551V
32
NKD-S947A
82
P225G
61
SB-801V
32
NKD-S947B
82
P225H
61
SC-831V
32
NKD-S947C
82, 83
P228A
65
V921
75
NKD-S947D
83
P228B
67
V922
75
100
www.nihonkohden.net
Index as per Model Code
Index as per Model Code
Model Code
page
Model Code
page
Model Code
page
Model Code
page
404617
28, 91
C-150
20, 54
NC-124D
18
TL-630T3
62
490933
13
F-150M
20, 54
NKB-102V
32
TL-631T3
62
6144-000427
18
F-150S
21, 55
NKB-301V
23, 32
V-040M4
54
6144-011852
18
FQS50-2-100
34
P-511
38
V-06OM6
55
669269
13
FQS50-3-100
34
P-513
38
V-09IO3
55
AX-250V
38
FQW210-10-295
25
P-530K
96
V-09OM3
54
AX-251V
39
FQW210-30-295
25
PS50-2
34
V-120S3
55
BC-753V
52
J-150
20, 54
RQS50-3
25, 34
X212A
96
BC-755V
52
JC-002P
52
RQS63-3
25
X216A
96
BC-763V
50
JC-005P
50, 51
SB-150D
23
X217A
96
BC-763VA
50
JC-761V
52
SB-201D
23
YC-210V
96
BC-765V
51
JC-762V
52
SB-831V
32
YG-101T
72
BC-765VA
51
JC-763V
52
SB-901D
23
YG-111T
75
BJ-831V
48
JC-855V
39
TG-101T
72
YG-120T
75
BJ-900P
48
JC-865V
38
TG-121T
74
YG-121T
75
BJ-901D
13
JC-906P
48
TG-221T
73
YG-122T
75
BJ-902D
13
JG-900P
72
TG-900P
72
YG-211T
73
BJ-903D
13
JG-920P
74
TG-901T3
72
YN-900P
79
BJ-904D
15
JG-970P
73
TG-920P
74
YN-901P
79
BM-901D
15
JL-550T2
58
TG-921T3
74
YN-990P
79
BR-002P
52
JL-900P
58
TG-970P
73
YP-710T
81
BR-004P
52
JP-900P
85
TL-051S
65
YP-711T
81
BR-018P
50
JP-910P
85
TL-052S
67
YP-712T
81
BR-019P
50
JP-920P
85
TL-061S
65
YP-713T
81
BR-020P
51
JP-921P
85
TL-062S
67
YP-714T
81
BR-021P
51
JP-960P
85
TL-201T
61
YP-715T
81
BR-202D
14
JT-900P
77
TL-201T1
61
YS-093P2
62
BR-903P
47, 50
L-150
20, 54
TL-220T
61
YSI-401
77
BR-906P
47
L-150X
20, 54
TL-271T
63, 64
YSI-402
77
BR-906V
47
LC-S2912NK
23, 32
TL-271T3
64, 66
YSI-409B
77
BR-912D
13
LCS-2012NK
23
TL-272T
63, 64
Z-101BC
28
BR-913D
13
LCT-1912ANK
23
TL-272T3
64, 66
Z-101EA
91
BR-913E
13
LCT-1912NK-1
32
TL-273T
63, 65
ZM: S616
77
BR-913P
47, 50
M-150
20
TL-273T3
64, 66
BR-916P
48
NA-0003
47
TL-274T
63, 65
BR-921D
14
NA-0003
50
TL-274T3
64, 66
For Germany, Austria, Switzerland and Benelux
NIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland
Albert-Einstein-Ring 9, 14532 Kleinmachnow, Deutschland
Fax: +49 (0) 33203/573-19, E-Mail: [email protected]
For Spain and Portugal
NIHON KOHDEN IBERICA S.L.
C/Ulises, 75A, 28043 Madrid, Spain
Fax: +34 91 300 46 76, E-Mail: [email protected]
For United Kingdom
NIHON KOHDEN UNITED KINGDOM Ltd.
Tolworth Tower – 19th Floor, Ewell Road, Surbiton,
Surrey KT6 7EL, United Kingdom
Fax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]
NKE-BRZ-K/A
For France
NIHON KOHDEN FRANCE SARL
8, rue François Delage, 94230 Cachan, France
Fax: +33 (0) 1 49 08 93 32, E-Mail: [email protected]
For Italy
NIHON KOHDEN ITALIA S.r.l.
Via Fratelli Bronzetti, 28, 24124 Bergamo, Italy
Fax: +39 (0) 35-232546, E-Mail: [email protected]
For all other European Countries, Russia, Turkey and Israel
NIHON KOHDEN EUROPE GmbH
Raiffeisenstraße 10, 61191 Rosbach v. d. H., Germany
Fax: +49 (0) 6003/827-599, E-Mail: [email protected]