JWL Series
Transcription
JWL Series
Vetek Weighing AB www.vetek.com JWL JWL Service Manual Series Service Manual May not be reproduced in any form without written permission PAGE 0 Vetek Weighing AB www.vetek.com JWL Service Manual Contents Assembly drawing 1 2 1–1 Explosive view (JWL) 2 1–2 List of parts (JWL) 3 1–3 Block diagram of electronic structure 4 1–4 Wiring diagram 5 Troubleshooting procedure 6 2–1 Troubleshooting flow 6 2–2 Troubleshooting table 7 2–3 Confirmation of application environment 7 2–4 Simple inspection of electric circuit 8 2–5 Performance inspection 8 Maintenance and setting 9 3–1 Maintenance flow 9 3–2 Model setting 9 Setting of parameters 10 4–1 Parameter setting 10 4–2 Description of parameter values 11 4–3 Unit setting 13 5. Linear calibration 17 6. Single point calibration 19 7. Error message list 21 8. External interface 22 8–1 RTC function setting 22 8–2 Signal output pins of three-in-one board 24 8–3 Single option 24 8–4 Two options 34 8–5 RS232 output format 36 9. Others 38 10. 41 10 – 1 Circuit diagram CPU, peripheral and other circuits 41 10 – 2 LCD circuit 42 Applicable mainboard version and software version 42 I. 2. 3. 4. 10 – 3 May not be reproduced in any form without written permission PAGE 1 Vetek Weighing AB www.vetek.com JWL Service Manual 1. Assembly Drawing 1 – 1 Explosive view May not be reproduced in any form without written permission PAGE 2 Vetek Weighing AB www.vetek.com JWL Service Manual 1-2 List of parts No. Name Quantity Part No. Material No. 1 xm JWL-Chinese front panel 1 JWL-1 21-1925-0100 2 xm key 1 JWL-2 21-0506-0100 3 xm level meter 1 JWL-3 02-0108-0003xm(14mm) 4 Xm transformer 1 JPL-4 61-0003-0400 5 Xm switch 1 JWL-5 60-0000-0000xm 6 Xm power socket 1 JWL-6 80-0125-0000 7 xm semi-finished JWL board 1 JPL-7 60-0503-0001xm 8 Xm lower cover 1 JWL-8 02-0000-6020 9 xm lower support 1 JWL-9 10-0425-0100 10 Xm 1 JPL-10 31-0404-0000xm screw for transport protection 11 Xm rubber levelers 4 JWL-11 01-0100-0030 12 xm RS232 board 1 JCL-12 80-0900-2200xm 13-1 xm sensor - Chung Yuen 3k 1 JWL-13 51-0400-0400xm 13-2 xm sensor - Chung Yuen 5k 1 JWL-13 51-0410-0000 13-3 xm sensor- Chung Yuen 10k 1 JWL-13 51-0410-0010 13-4 xm sensor - Chung Yuen 20k 1 JWL-13 51-0410-0020 13-5 xm 1 JWL-13 51-0410-0040 Yuen sensor - Chung 40k 14 Xm storage cell 1 JWL-14 61-0201-0098xm 15 Xm cell cover 1 JWL-15 02-0000-6030 16 Xm rear PCB 1 JPL-16 80-0126-0010 17 xm upper support 1 JWL-17 10-0425-0000 18 xm upper cover 1 JWL-18 02-0000-6010 19 xm rear panel 1 JWL-19 20-0000-6040 20 xm plastic down-warped pan 1 JCL-20 02-0000-6040 21 xm 1 JCL-21 12-0000-1200 stainless steel down-warped pan May not be reproduced in any form without written permission PAGE 3 Vetek Weighing AB www.vetek.com JWL Service Manual 1 – 3 Block diagram of electronic structure May not be reproduced in any form without written permission PAGE 4 Vetek Weighing AB www.vetek.com JWL Service Manual 1 – 4 Wiring diagram(圖中中文應去除) May not be reproduced in any form without written permission PAGE 5 Vetek Weighing AB www.vetek.com JWL Service Manual 2. Troubleshooting Procedure 2– 1 Troubleshooting flow START LED acts or not LCD, backlight, buzzer, No Yes No Check battery wiring for loosening LCD displays completely or not No Check battery for damage or power failure Yes Check, repair machine board or replace it No Connect battery wiring Confirm application environment Yes Return to START Return to START LCD display status Charge or replace battery Check power supply switch for failure Yes LCD display Err5 Check for AD internal No COUNT value Yes Replace machine board and repair Cannot zero or STABLE flashes No Check AD COUNT value for instability, replace machine board, and repair, interference exists or not Can it work or be charged with AC power supply Replace power supply switch Can zero or not No Yes Yes Object interference exists near scale pan or not Charge or replace battery Return to START No Display weight Return to START Return to START Adjust AD value Transport protective screw is disassembled or not No Can weigh or not No No Replace machine board, and repair Yes Return to START Return to START Yes or replace LOAD-CELL Return to START No Check, repair machine board or replace it Zero point, weighing is stable or not Yes Recalibrate zero point Remove transport protector Return to START Replace machine board, and repair, interference exists or not Yes Return to START Keys are normal or not Return to START No Return to START Yes Check machine board or replace KEYBOARD Weight display can display to MAX+9e or not No Replace machine board and repair Return to START Yes Remove interfering object Check transformer for damage Return to START Yes Replace transformer Weight is accurate or not Return to START No Yes No Linear calibration Return to START Linearity is good or not Yes Linear calibration Return to START Unbalanced load is normal or not Return to START No Yes Correct error at the No Residual creep exists or not Performance and function test four corners Yes Check LOAD-CELL for failure Return to START Return to START Return to START May not be reproduced in any form without written permission PAGE 6 Vetek Weighing AB www.vetek.com JWL Service Manual 2– 2 Troubleshooting table Error message Causes LCD, 1. Cell or transformer fault backlight board 2. Power switch fault or 3. Power circuit fault buzzer 4. LCD or related LCD circuit fault does not work 5. Backlight board or backlight related circuit fault 6. Buzzer fault or buzzer circuit fault 7. CPU or oscillating circuit fault AC current or cell can’t be used. 1. Power socket fault 2. Transformer fault 3. Cell fault 4. Power circuit fault 5. Main board fault Err5 1. Overload (max weighing +9e) 2. Too high or inaccurate calibrated COUNT value. Cell sign 1. Insufficient cell voltage or cell failure 2. Main board fault Instable 1. The pan is interfered by any article. indication Bad linearity 2. There is strong wind or vibration nearby. 3. The cell voltage is insufficient. 4. There is external electromagnetic interference. 1. The pan is interfered by any article. 2. Bad L/C 2– 3 Confirmation of the application environment a. Is there a strong wind in the workplace? b. Is there vibration or instability in the workplace? c. Is there any article on the pan? d. Is the stainless steel pan placed on the tray? e. Has the screw for transport protection been removed? f. Is the scale set on a horizontal plane? 2 –4 Simple inspection of electric circuit a. Check if the power supply is normal May not be reproduced in any form without written permission PAGE 7 Vetek Weighing AB www.vetek.com JWL Service Manual 1. Is the voltage 5V at both E+ and E- terminals? Check whether the CPU supply is normal. b. Check the signal input 1. Check if the outputs from S+ and S- terminals to G change in accordance with the weight on the pan. c. Check the digital signals (1) Check if there is oscillation in Y1’s output pin. (2) Check if there is oscillation in Y2’s output pin. 2 – 5 Performance Inspection a. Repetitiveness Put the weight of two thirds of the load on the pan for five times , the indication difference between different times should be less than or equal to one division value. b. Unbalanced loading error Put the weight of one third of the load on the pan (as shown in the figure). Check if the figure is precise. The indication difference between the four corners should be less than or equal to one division value. a c e b d c. Linearity Load conditions Idle ~ one third of the load One third of the load ~ two thirds of the load Two thirds of the load ~ full load May not be reproduced in any form without written permission Permissible error 0e 1e 2e PAGE 8 Vetek Weighing AB www.vetek.com JWL Service Manual 3. Maintenance and Setting 3 – 1 Maintenance flow Change LOAD-CELL Model setting Refer to Page 9 Linear calibration Refer to Page 17 Single point calibration Refer to Page 19 Parameter setting Refer to Page 10 Performance inspection Refer to Page 8 3 –2 Model setting Model setting: Press MR to turn on the unit (the LCD will display 3.0000) and then press UNIT to select the unit model (for example:1.50000, 3.0000, 6.0000, 7.5000, 15.0000, 30.000 ). Press G/N and the unit will display “dIu-01” and enter accuracy selection. Press UNIT to select from diu-01 (1/30000), diu-02 (1/15000), diu-03(1/6000), diu-04 (1/3000), etc. and then press G/N to store the setting and return to the weighing mode. May not be reproduced in any form without written permission PAGE 9 Vetek Weighing AB www.vetek.com JWL Service Manual 4. Setting of Parameters 4-1 Parameter setting (1). In weighing mode, press and hold down for 3s or press and release it till the unit is on. will appear first and then a parameter value such as ” ” will appear, accompanied by an auxiliary sign (2). Use or . to select the parameter items (as shown in the table below). (3). Use or to select the values of parameters. (4). When the setting is completed, press to store the setting and return to the weighing mode. May not be reproduced in any form without written permission PAGE 10 Vetek Weighing AB www.vetek.com JWL Service Manual 4-2 Description of parameter values Item Function Display Description No setting ☆ Automatic turn-off will be executed when the P00 weight is smaller than 9 divisions. 5 min 10 min 30 min 60 min 90 min P01 Buzzer beep ☆ ☆ There will be an acoustic warning when the weight of the material is between the preset upper and lower limits (including the upper and lower limits). There will be an acoustic warning when the weight of the material is beyond the preset upper and lower limits and the weight is more than 20 divisions. There will be an acoustic warning when the weight of the material is less than the preset lower limit and the weight is more than 20 divisions. There will be an acoustic warning when the weight of the material exceeds the preset upper limit. PC output Dot-matrix P02 Printer selection RS-232 P03 transmission rate May not be reproduced in any form without written permission Automatic sticking, paper size: 5cm*3cm Automatic sticking, paper size: 5cm*3cm Automatic sticking, paper size: 5cm*3cm The transmission rate is 2400 The transmission rate is 4800 PAGE 11 Vetek Weighing AB www.vetek.com ☆ Turn-on or off of the weight check P04 memory ☆ ☆ P05 Parity check JWL Service Manual The transmission rate is 9600 Automatic turn-on of the check mode when the unit is turned on next time. No automatic turn-on of the check mode when the unit is turned on next time. No parity. The parity can be odd or even. Backlight display will be on for the whole process No backlight display P06 Backlight selection ☆ Backlight display will be on when the weight is greater than 9 divisions. Manual printing P07 Printing mode selection ☆ Stable printing (the next printing will be made only when the indication is returned to zero.) Continuous printing ☆ Worst vibration resistance Average vibration resistance Filter grade P08 selection Good vibration resistance Best vibration resistance P09 Zero indication range ☆ May not be reproduced in any form without written permission No restriction indication PAGE on the zero 12 Vetek Weighing AB www.vetek.com JWL Service Manual At a zero indication, only when at least 2 divisions or above is put on the pan will a value be indicated. At a zero indication, only when at least 3 divisions or above is put on the pan will a value be indicated. At a zero indication, only when at least 4 divisions or above is put on the pan will a value be indicated. At a zero indication, only when at least 5 divisions or above is put on the pan will a value be indicated. At a zero indication, only when at least 6 divisions or above is put on the pan will a value be indicated. P10 Factory initialized setting P11 Unit setting It is a factory set value. The specific operation is as follows: 4-3 Unit setting (1). Mode 1: press to turn on the unit till the left picture appears. Mode 2: in the weighing May not be reproduced in any form without written permission PAGE 13 Vetek Weighing AB www.vetek.com JWL Service Manual mode, press 3s, press for about or to select the parameter P11 and press to enter the left picture with appearing on the lower left corner. (2). Press to select the unit from g\ kg\ lb\ jin-liang for the scale. (3). Press to store the selection and switch to the setting of unit for use, with appearing on the lower left corner. (4). Press to switch the unit for use. Press to select turn-on or turn-off of this unit. May not be reproduced in any form without written permission PAGE 14 Vetek Weighing AB www.vetek.com JWL Service Manual (5). Press to store the selection and switch to the memory unit of the scale, with appearing on the lower left corner. (6).Press and select YES (the unit will be the previously used one when the scale is turned on) or NO (the unit will be a newly set one when the scale is turned on). (7).Press to store the selection and return to the weighing mode. Note: If the unit setting is accessed from the parameter options or by Mode 2, press to store the selection and then press to return to the weighing mode. May not be reproduced in any form without written permission PAGE 15 Vetek Weighing AB www.vetek.com JWL Service Manual 5. Linear Calibration ☆If the linear calibration is made, there is no need to make the single point calibration. If the sensor has a good linearity, make the single point calibration directly. (1).Press to turn on the unit and release the key when appears on the LCD, the linear calibration mode is entered. (2).Press to do the zero point calibration and wait for ON 0 to appear (No weight is put on the pan at this time). (3). Wait till ON 1 flickers on the LCD and put on the weight 1/3 of the full load. For example, 1/3 of the weighing 30kg is 10kg. May not be reproduced in any form without written permission PAGE 16 Vetek Weighing AB www.vetek.com JWL Service Manual (4). Wait till ON 2 flickers on the LCD and put on the weight 2/3 of the full load. For example, 2/3 of the weighing 30kg is 20kg. (5). Wait till ON 3 flickers on the LCD and put on the weight of the full load. (6). Wait till PASS appears. Now, take away the load from the pan. (7).Press to return to the weighing mode. May not be reproduced in any form without written permission PAGE 17 Vetek Weighing AB www.vetek.com JWL Service Manual 6. Single Point Calibration(底下少圖 底下少圖) 底下少圖 (1).Press to turn on the unit and release the key when appears, the single point calibration mode is entered. (2). Press and wait till ZERO flickers. Now make the single point calibration. (3). Wait till a value appears and the most right digit flickers. Press or to move the flicker right or left. (4). Press or to alter the value. (5). After the setting, put a corresponding weight on the pan and press . When the LCD flickers, make the single point calibration. May not be reproduced in any form without written permission PAGE 18 Vetek Weighing AB www.vetek.com JWL Service Manual (6). Wait till PASS appears. Now, take away the load from the pan. (7). Press to return to the weighing mode. May not be reproduced in any form without written permission PAGE 19 Vetek Weighing AB www.vetek.com JWL Service Manual 7. Error Message List Error message Possible causes Solutions E02 no.samp No PCS sampling E04 EE.ERR EEPROM reading error Re-weld the EEPROM or contact the service department. E05 out.ran Overload (max weighing+9 divisions) Take away the overload. E07 E.Lo>Hi The upper limit set for the weight check is lower than the lower limit. Press sampling. to make the Press to correct the setting of HI/LO. The unit set for the weight Close the weight check or re-set E08 CK.UNIT check is not the same as the the value of HI /LO. current unit. EU.nit Interference between the accumulation units May not be reproduced in any form without written permission Return to the last accumulation unit or re-do the accumulation. PAGE 20 Vetek Weighing AB www.vetek.com JWL Service Manual 8. External Interface ☆ If an external interface is needed, please select a three-in-one board, which combines RTC (time display) ,RS-232 and Relay (weight check) on one circuit board. Only by selecting this board can the three functions be realized. ☆ After a three-in-one board is selected, a setting should be made on the scale for time display if necessary. 8-1. RTC function setting (1). Press for 3s till time display appears, with on the lower left corner. (2). Press or to switch to date-month or year display. Note: For time/date setting, skip to Step 3 and for returning to the weighing mode, press (3). Press . to enter the setting for the current time and the last digit for second will flicker, with appearing on the lower left corner, representing that the first digit from right to left can be altered. May not be reproduced in any form without written permission PAGE 21 Vetek Weighing AB www.vetek.com JWL Service Manual (4). Press to move between the digits and a corresponding digit will flicker when the movement is made from right to left. Now, press or to increase or decrease the value. Note: or You may press to switch to the setting for date-month or year. (5). Press to complete the time setting and display the time/date that is already set. To return to the weighing mode, press Note: This time/date setting should be made again when the scale is turned on next time if a three-in-one board is not selected for the scale. May not be reproduced in any form without written permission PAGE 22 Vetek Weighing AB www.vetek.com JWL Service Manual 8-2 Signal output pins of three-in-one board 8-3 Single option 8-3-1 Printer output ■Parameter setting (1). In weighing mode, press for about 3s or press and release it when the scale is turned on. will first appear and then a parameter value such as ” ” and also an auxiliary sign . May not be reproduced in any form without written permission PAGE 23 Vetek Weighing AB www.vetek.com JWL Service Manual (2).Use or to select a parameter item such as PO7. Press or to select the parameter value, with the printing modes including / / . (3). Follow Step (2) to select the parameter item P02, with the printing modes including / / / . (4). Follow Step (2) to select the parameter item P03, selecting the Baud rate of . ■Wire connecting the scale and the printer Wire connecting ZEBRA That is the commonly used 9male ~25male RS232 connecting wire. Wire connecting SH-24 That is the commonly used 25male~25 male RS232 connecting wire. You have to exchange by yourself the pin 2 with the pin 3 May not be reproduced in any form without written permission PAGE 24 Vetek Weighing AB www.vetek.com JWL Service Manual at one end of the wire bought. Wire connecting BP545D Wire connecting GODEX That is the commonly used 9male ~25male That is the commonly used 9male ~25male RS232 connecting wire. RS232 connecting wire. 8-3-2 PC output ■Parameter setting (1). In weighing mode, press for about 3s or press and release it when the scale is turned on. will first appear and then a parameter value such as ” ” and also an auxiliary sign . (2). Use or to select a parameter item such as PO7. Press May not be reproduced in any form without written permission PAGE or to 25 Vetek Weighing AB www.vetek.com JWL Service Manual select the parameter value, with the printing modes including / / . (3). Follow Step (2) to select the parameter item P02, with the printing mode selected as . (4). Follow Step (2) to select the parameter item P03, selecting the Baud rate from / / . (5).When the setting is completed, press to store the setting and return to the weighing mode. ■Wire connecting the scale and the PC How to use a PC to receive the weighing information? (1) Use the connecting wire as shown in the following figure to connect the scale and the PC. (2) Set the printing mode as continuous. (3) Now, the scale will output the data to the PC. (Of course, you must have a receiving program at the PC end.) May not be reproduced in any form without written permission PAGE 26 Vetek Weighing AB www.vetek.com JWL Service Manual That is the commonly used 9 female ~25male RS232 connecting wire. You have to exchange by yourself the pin 2 with the pin 3 at one end of the wire bought. Note: The hollow dots represent that the connectors are male and the black dots, female. 8-3-3 Warning light connection for use ■ Parameter setting of beeps for weight check: (1). In weighing mode, press for press about 3s or and release it when the scale is turned on. will first appear and then a parameter value such as ” ” and also an auxiliary sign . (2). Use or to select a parameter item such as PO1. Press or to select the parameter value, with four modes / / / for selection. May not be reproduced in any form without written permission PAGE 27 Vetek Weighing AB www.vetek.com JWL Service Manual (3). When the setting completed, press is to store the setting and return to the weighing mode. ■ Setting for the upper and lower limits of weight check (1). In press Triangle indicator for the upper or lower limit weighing mode, for 3s and the screen enters the state for digit entry. Enter the value at the first zero on the right which flickers on the LCD. (2). Press or to move the flickering cursor left or right to the digit where you want to enter a value. (3). Press to increase the value or to decrease the value and select the weight value you want to enter. (4). Repeat Steps (2) and (3) to complete the setting for the upper limit. For example, 10.000kg. May not be reproduced in any form without written permission PAGE 28 Vetek Weighing AB www.vetek.com JWL Service Manual Note: After completing Step (4), you may directly press to store the upper limit value or directly skip to Step (6). (5). Press Triangle indicator for the upper or lower limit for 3s and the screen enters the state for digit entry. Repeat Steps (2), (3) and (4) to complete the setting for the lower limit. For example, 1.000kg. Note: you may directly press to store the lower limit value or directly skip to Step (6). (6). Press to start or cancel the check. (7). Press to return to the weighing mode. If the triangle indicator for the upper or lower limit appears, it is in the check mode. Note: Only when the lower limit ≦the upper limit value can the check mode be started. It is the same for other unit setting. May not be reproduced in any form without written permission PAGE 29 Vetek Weighing AB Note: www.vetek.com JWL Service Manual - 1. When the material weight exceeds 10.000kg, there will be an acoustic warning and the red light will be on. 2. When the material weight is smaller than or equal to 10.000kg and greater than or equal to 1.000kg, the green warning light will be on. 3. When the material weight is smaller than 1.000kg and greater than or equal to 20 divisions, the orange warning light will be on. - 1. When the material weight exceeds 10.000kg, there will be an acoustic warning and the red light will be on. 2. When the material weight is smaller than or equal to 10.000kg and greater than or equal to 1.000kg, the green warning light will be on. 3. When the material weight is smaller than 1.000kg and greater than or equal to 20 divisions, there will be an acoustic warning and the orange warning light will be on. - 1. When the material weight exceeds 10.000kg, the red light will be on. 2. When the material weight is smaller than or equal to 10.000kg and greater than or equal to 1.000kg, there will be an acoustic warning and the green warning light will be on. 3. When the material weight is smaller than 1.000kg and greater than or equal to 20 divisions, the orange warning light will be on. -1. When the material weight exceeds 10.000kg, the red light will be on. 2. When the material weight is smaller than or equal to 10.000kg and greater than or equal to 1.000kg, the green warning light will be on. 3. When the material weight is smaller than 1.000kg and greater than or equal to 20 divisions, there will be an acoustic warning and the orange warning light will be on. ■Pins for connecting the warning lights Pins for connecting the warning lights May not be reproduced in any form without written permission Picture PAGE 30 Vetek Weighing AB www.vetek.com JWL Service Manual The pins for the warning lights are connected to the 25-male socket. ■ Wire connecting the scale and the warning light Wire connecting the warning lights Picture That is the commonly used 25male and 25 female RS232 connecting wire. Note: The hollow dots represent the male connectors and the black dots, female connectors. 8-4. Two options May not be reproduced in any form without written permission PAGE 31 Vetek Weighing AB www.vetek.com JWL Service Manual 8-4-1 Joint use of PC output and warning light 8.4.1.1 The parameter setting is the same as specified in 8-3-2, 8-3-3 8.4.1.2 Wire connecting the scale to the PC and the warning light Wire connecting the PC and the warning light Picture Note: The hollow dots represent the male connectors and the black dots, female connectors. 8-4-2 Joint use of SH-24 printer output and warning light 8-4-2-1 The parameter setting is the same as specified in 8-3-1 and 8-3-3 8-4-2-2 Wire connecting the scale to the SH-24 printer and the warning light Wire connecting the SH-24 printer and the warning light Picture May not be reproduced in any form without written permission PAGE 32 Vetek Weighing AB www.vetek.com JWL Service Manual Note: The hollow dots represent the male connectors and the black dots, female connectors. 8-4-3 Joint use of ZEBRA or other printers and warning light 8-4-3-1 The parameter setting is the same as specified in 8-3-1 and 8-3-3 8-4-3-2 Wire connecting the scale to a ZEBRA or other printers and the warning light Wire connecting the ZEBRA/GODEX(EZ)/BP 545D printer and the warning light Picture 8-5. RS-232 output format Baud Rate: 2400, 4800, 9600 Data Bit: 8 May not be reproduced in any form without written permission PAGE 33 www.vetek.com Vetek Weighing AB JWL Service Manual Parity: N (None) Stop Bit: 1 Code: ASCII Bit Format: LSB MSB 0 1 2 3 4 5 6 7 8 Start Bit Parity Stop Bit Data Format: g N . W . T . W . G . W . : : : +/- g CR LF +/- g CR LF +/- g CR LF +/- k g CR LF +/- k g CR LF +/- k g CR LF +/- l b CR LF +/- l b CR LF +/- l b CR LF Weight Example N.W.: + 1000.0 g T.W.: + 500.4 g G.W.: + 1500.4 g kg N . W . T . W . G . W . : : : Weight Example N.W.: + 1.0000 kg T.W.: + 0.4998 kg G.W.: + 1.4998 kg lb N . W . T . W . G . W . : : : Weight Example N.W.: + 2.2050 lb T.W.: + 1.1020 lb G.W.: + 3.3070 lb Jin (Taiwan) N . W . T . W . : : +/- G - t l . T CR LF +/- G - t l . T CR LF May not be reproduced in any form without written permission PAGE 34 www.vetek.com Vetek Weighing AB G . W . : JWL Service Manual +/- G - t l . T CR LF +/- G - t l . H CR LF +/- G - t l . H CR LF +/- G - t l . H CR LF Weight Example N.W.: + 1.94.8 G-tl.T T.W.: + 0.13.2 G-tl.T G.W.: + 2.08.0 G-tl.T Jin (Hong Kong) N . W . T . W . G . W . : : : Weight Example N.W.: + 1.94.4 G-tl.H T.W.: + 0.13.2 G-tl.H G.W.: + 2.07.6 G-tl.H PCS t o t a l : CR LF p c s CR LF Example Total: 50pcs 9. Others May not be reproduced in any form without written permission PAGE 35 Vetek Weighing AB www.vetek.com JWL Service Manual 9-1 Options Example of use of single option External device Option Output format RS232+RTC+Relay AP0 → + PC RS232+RTC+Relay AP1 → + BP-545D RS232+RTC+Relay AP2 + → SH-24 RS232+RTC+Relay AP3 → + ZEBRA May not be reproduced in any form without written permission PAGE 36 Vetek Weighing AB www.vetek.com JWL Service Manual RS232+RTC+Relay AP4 + Applicable to the quality control → of the factory product quantity or weight and that of the total production line. LED Light Tower RS232+RTC+Relay AP5 + GODEX(EZ) Examples of use of options May not be reproduced in any form without written permission PAGE 37 Vetek Weighing AB www.vetek.com JWL Service Manual Option External device or or or AP1 → or + LED Light Tower PC / SH-24 / ZEBRA / EZ / BP-545D 10 Circuit Diagram May not be reproduced in any form without written permission PAGE 38 www.vetek.com Vetek Weighing AB JWL Service Manual 10-1. CPU, peripheral circuit and other circuits MCB1 +5VD MCB2 +5VA BAT AVS1 13 14 29 G 9 10 11 12 CS AIN0 ACDD AIN1 AGND AD SCLK 13 0.1u,G 1u,T CP10 AD SDO 12 AD SDI 11 +5VA AD CS 10 9 CP11 C10 0.1u,G 1u,T CS1180 MCB8 R3 R52 560R,C R27 330Ω,C U11 5 6 7 8 +5VD VOUT LV DSC V+ C35 4 3 2 1 CAPGND CAP+ NC 220u,EL G 1N41 48 7660 1 LED 1 C36 470u,EL D8 BZ 0.1u,G A733 Q8 CN7 -5VD 2 1 2 -5VD 2SC1815 F CP16 Q11 R5320k,C Q9 2SC1815 1 P 2. 4 P 2. 3 P 2. 2 REFN 14 C9 +5VD Y3 Y2 Y1 Y0 B A +5VD 28 27 26 25 24 SDI AD RST 100,A,T 30 P 2. 0 23 CN9 ON/OFF 2 1 1M,C BAT 2 J1 1 4 2 + 1.5k,A R9 R8 4.7k,C 3 R55 CN3 1k,C + 1 2 R56 10k,A R66 AVS7 R64 CP12 47k,C 0.1u,G C12 Battery 470u,EL 47K,C D3 1N4148 R22 C2 1N4148 1 2 R20 4 3 C16 CP13 470u,EL 0.1u,G U15C U15B 3 OUT 220u,EL 2.2k,C U15A IN C15 R23 2SC1815 10k,C 1 2SB857 330k,C 104P 3 Q5 R65 2 Q6 D4 GND C11 2/1w,C +5VD U3 LM2930 D2 1N4004 R7 3 2 AVS5 AVS6 3 1 1 1 1 0 1 2 EH-Adpator 4 70 u /2 5 v, E L TP1 TP2 TP3 CAL 1 2 2 2 2 1 Q1 2 D313 U5 1 FUSE CN2 2 22 21 20 19 18 SDO REFP 0.1u,G CP7 EH-BUZZER 20p SCLK DGND 15 1M,A,T MCB7 U9B 15 31 C21 11.059MHz R28 8 XTAL 16 34 33 32 8 7 6 5 V CC WP SCL SD A A0 A1 A2 GND 1 2 3 4 RTC +5VD CN6 20p 7 DRDY CP8 36 3 C20 CP6 DVDD MCLK 0.1u,G 37 22k,C R25 Y1 0.1u,G CP5 AVS4 3 CW 1 2 6 0.1u,G 3 2 1 1 0 0 k ,C R26 5 6 2 1M,C 7 6 5 4 D5 D6 D7 OK HI LO U4 1 Out Vdd 2 CP14 0.1u,G C19 470u,EL C18 +5VD R51 1k,C R49 1k,C R50 1k,C R17 CN4 4 3 2 1 RS232 R12 R14 1k,C 1K,C +5VD R13 R16 Q2 3 Q3 100k,C 3 1k,C 2SC1815 Q4 A733 FB2 3 R19 10k,C 1 2SC1815 +5VD 1k,C 4.7k,C D1LED-RL RXD TXD 220u,EL R18 4.7k,C R15 1 U9.16 +5VA LM2931 2SC1815 U9.8 2 P 3. 2 P 2. 0 74LS139 Q7 3 R24 10k,C 3 B A Y3 Y2 Y1 Y0 470P 2 3 2 G 14 13 12 11 10 9 8 2 1 NC NC CURLIM COMP CURSEN V+ INVc IN+ Vout Nref Vz VNC 330k,C 1 1 2 3 4 5 6 7 U9A C13 V ss R21 U1 LM723 1 4 .7 k .C U8 HT24C02A 5 R1 3 P2.5 P 2. 1 P3.5/(T1) 4 +5VA +5VD DGND P3 P2.6 R2 100,A,T 2 P2.7 P3.4/(T0) MCB6 AVS3 LOAD-CELL 2 P3.3 / (not INT1) 4 .7 k .C 4 .7 k .C +5VD PSEN P 2. 0 17 CP18 R31 R30 R29 0.1u,G ALE / not PROG P3.2 / (not INT0) 3 MCB5 5 S- R54 16 P4.1 P3.1 / (TXD) 3 4 S+ CN10 38 35 U6 1 FB1 3 30 k ,C 15 not EA / VPP AT89C51/52 P4.3 P 4. 0 14 P0.7 U7 P3.0 / (RXD) GND 13 P0.6 RST XTAL 4 .7 k .C 12 P3 TXD P3.2 P1.7 39 20p R4 1M,C MCB4 2 M 41 42 40 P 0. 3 P 0. 2 P 0. 0 P 0. 1 44 1 P 4. 2 3 4 5 2 P 1. 0 P 1. 1 P 1. 2 P 1. 3 6 11 P0.5 XTAL 10 RXD P0.4 P1.6 P 3. 7 / (n o t R D ) 9 LCD-DATA P1.5 P 3. 6 / (n o t W R ) 10u,EL R32 MCB3 C8 4.9152MHz Y2 1 JWEL R63 R62 R61 4 .7 k .C 8 20p 2 G 9 8 7 6 5 4 3 2 1 +5VD 4 .7 k .C 7 LCD-CS AVS2 4 .7 k .C P 1. 4 43 A D CS A D RST CN8 KIN1 KIN2 KIN3 KIN4 KIN5 +5VD LCD-WR CN1 E- R36 10k,C C7 10u,T R44 R45 R46 E+ V CC 2 R35 10k,C C22 R41 R42 R43 10K,C 10K,C 10K,C 10K,C 10K,C 10K,C 10K,C 10K,C10K,C SCL K Q10 A733 3 R38 R39 R40 0.1u,G C1 1 A D SD O 1 R34 10k,C A D SD I CP17 KO UT1 KO UT2 KO UT3 KO UT4 +5VD Title JWL V1.1 Size Number Revision A2 Date: File: May not be reproduced in any form without written permission PAGE 1-Sep-2008 E:\jadever\LX资料料\L-SCALE.ddb Sheet of Drawn By: 39 www.vetek.com Vetek Weighing AB 33p C47 33p C48 33p 33p 33p 33p CS9 CS8 C52 33p C53 33p 24 23 22 21 20 19 18 17 16 33p C46 C54 33p C55 33p C56 33p C57 33p C58 33p C59 33p 33p S16 S15 S14 S13 S12 S11 S10 S9 S8 33p C45 S25 S24 S23 S22 S21 S20 S19 S18 S17 33p C44 33 32 31 30 29 28 27 26 25 C43 CS11 CS15 C51 C49 C50 C42 CS12 CS16 CS20 CS18 CS17 CS19 CS21 CS22 LCD circuit CS24 10-2. JWL Service Manual 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 S1 S2 S3 S4 S5 S6 S7 C4 C3 C2 C1 C1 C2 C3 C4 LCD4 33p 33p 33p CC3 CS7 C66 CS5 C65 33p C67 C68 33p C69 33p C70 33p 33p CC2 33p C64 CS6 33p C63 CS2 33p C62 CS4 C61 CS1 C60 CS3 U14 1 2 3 4 5 6 7 8 9 10 11 12 13 R57 220Ω,C R58 4700Ω,C CP19 0.1u,G 14 15 16 17 18 19 20 21 22 23 24 KIN3 SW1 SW2 1 2 1 2 1 SEG7 SEG6 SEG5 SEG4 SEG3 SEG2 SEG1 SEG0 CS RD WR DATA Vss SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 OSC0 OSC1 SEG22 SEG23 SEG24 SEG25 SEG26 SEG27 SEG28 SEG29 SEG30 SEG31 VLCD VDD IRQ BZ BZ COM0 COM1 COM2 COM3 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 HT1621B SW3 2 1 2 1 2 KIN4 SW4 SW5 1 SW6 LED4 2 KIN5 SW7 SW8 1 2 SW9 1 2 1 2 6 5 4 3 2 1 + + + + + + 6 5 4 3 2 1 K OU T3 K OU T2 K OU T1 Title Size Number Revision A3 Date: File: 1-Sep-2008 E:\jadever\LX 资料料\L-SCALE.ddb Sheet of Drawn By: 10 - 3. Applicable mainboard version and software version Mainboard version: JWL-V1.1 (50-0900-0000) Software version: JWL1.01 Revision date: Nov. 28, 2008 May not be reproduced in any form without written permission PAGE 40